Samsung SDS 365PLUS Digital door lock User Manual manual english 365plus

Samsung SDS Co., Ltd. Digital door lock manual english 365plus

User Manual

Download: Samsung SDS 365PLUS Digital door lock User Manual manual english 365plus
Mirror Download [FCC.gov]Samsung SDS 365PLUS Digital door lock User Manual manual english 365plus
Document ID2568339
Application IDznZe3KWzBrsXTPPoEIQEbA==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize10.72kB (134019 bits)
Date Submitted2015-03-27 00:00:00
Date Available2015-03-27 00:00:00
Creation Date2015-03-25 20:35:20
Producing SoftwareAcrobat Distiller 11.0 (Windows)
Document Lastmod2015-03-27 10:57:21
Document TitleMicrosoft Word - manual_english_365plus_.doc
Document CreatorPScript5.dll Version 5.2.2
Document Author: hwj

『This manual was prepared for the certification test.』
 Product Specifications
Item
Size
365Plus
Exterior Unit
58mm(W)×113mm(H)×16.8mm(D)
Interior Unit
70.4mm(W)×163.8mm(H)×38mm(D)
Card
85.5mm(W)×54.0mm(H)×0.9mm(D)
Voltage
Emergency Power Source
Battery Life
Support Card Standard
4 AA Alkaline 1.5V Batteries (LR6) (6V)
9V Battery(6LF22)
(Separately sold)
10 Months (based on an average of 6 uses per day)
ISO14443A (Mifare®), ISO 15693
 Exterior/Interior Parts
Touchscreen
Card Reader
Restart Button
External Power Port
Network Module Slot
[REG] Button
[OPEN/CLOSE] Button
[SET] Button
Magnetic Sensor
Thumbturn Lever
“You could register the Master card and user PIN code/card after changing default Master PIN
code and user PIN code.”
 Basic Functions
1. Initialization
1.1 User Initialization
All registered User data(user PIN Code/Card) will be deleted, and Super User PIN Code is
set to ‘5678’. The Master data and Paring information aren’t delete.
① Press the [REG] button.
② Press the [*] button after pressing the [4] button.
③ Press the [*] button after pressing the [3] button.
④ Enter a Master PIN Code or Super User PIN Code, and press the [*] button.
1.2 Master Initialization(Reset to Factory Default)
All registered Master/User data will be deleted, and Master PIN Code is set to ‘1234’, User
PIN Code is set to ‘5678’. Also Paring information is deleted.
① Press the [REG] button.
② Press the [*] button after pressing the [4] button.
③ Press the [*] button after pressing the [1] button.
④ Enter a Master PIN Code, and press the [*] button.
2. Changing the Master PIN Code
① Press the [REG] button.
② Press the [*] button after pressing the [1] button.
③ Press the [*] button after pressing the [2] button.
④ Enter the current Master PIN Code, and press the [*] button.(default ‘1234’)
⑤ Enter the new Master PIN Code, and press the [*] button.(4~10digits)
3. Registering a Master Card
You can register up to 9 Master Cards.
① Press the [REG] button.
② Press the [*] button after pressing the [1] button.
③ Press the [*] button after pressing the [1] button.
④ Enter the Master PIN Code, and press the [*] button.
⑤ Press the [*] button. Then ID Number is displayed. (242~250)
⑥ Place the Card on the Card Reader.
⑦ Press the [*] button for the addtional registration or press the [REG] button to quit.
4. Deleting a Master Card
① Press the [REG] button.
② Press the [*] button after pressing the [1] button.
③ Press the [*] button after pressing the [3] button.
④ Enter the Master PIN Code, and press the [*] button.
⑤ Enter the ID Number(242~250) and press the [*] button. Or place the card to be deleted.
⑥ Enter another ID Number or press the [REG] button to quit.
5. Changing the User PIN Code
① Press the [REG] button.
② Press the [*] button after pressing the [2] button.
③ Press the [*] button after pressing the [2] button.
④ Enter the current User PIN Code, and press the [*] button.
⑤ Enter the new User PIN Code, and press the [*] button.(4~10digits)
6. Registering a User PIN Code/Card
You can register up to 240 User Data(PIN Code/Card).
① Press the [REG] button.
② Press the [*] button after pressing the [2] button.
③ Press the [*] button after pressing the [1] button.
④ Enter the Super User PIN Code, and press the [*] button.
⑤ Press the [*] button. Then ID Number is displayed. (1~240)
⑥ Enter a new User PIN Code and press [*] button. Or place the Card on the Card Reader.
⑦ Press the [*] button for the addtional registration or press the [REG] button to quit.
7. Deleting a User PIN Code/Card
① Press the [REG] button.
② Press the [*] button after pressing the [2] button.
③ Press the [*] button after pressing the [3] button.
④ Enter the Super User PIN Code, and press the [*] button.
⑤ Enter the ID Number(1~240) and press the [*] button. Or place the card to be deleted.
⑥ Enter another ID Number or press the [REG] button to quit.
8. Pairing/Unparing with a Home Controller
8.1 Pair to a Home Controller
After pairing with a home controller, you can use User Card.(Registration/Enterance)
① Press the [REG] button.
② Press the [*] button after pressing the [3] button.
③ Press the [*] button after pressing the [1] button.
8.2 Check the Completion of Paring
This is to check if “Pair to a Home Controller” is successfully completed.
① Press the [REG] button.
② Press the [*] button after pressing the [3] button.
③ Press the [*] button after pressing the [2] button.
8.3 Unpair from a Home Controller
After unpairing the door lock from a home controller, it will no longer be remotely-controlled
via the home controller. And you couldn’t use User Card.
① Press the [REG] button.
② Press the [*] button after pressing the [3] button.
③ Press the [*] button after pressing the [3] button.
9. Opening the Door with a PIN Code/Card
① Touch the [Touchscreen].
② Enter the PIN Code and press the [*] button. Or place the Card on the Card Reader.
③ The door opens whithin one second.
 Addtional Function
10. Privacy Mode Functions
Press and hold the [OPEN/CLOSE] button for more than five seconds, if five beeps
deactivate the Keypad. As it is set from the inside, provides a secure lock for the convenience
of the occupant(s). Privacy mode disables remote control capabilities.
11. Setting the Security Function
Function that allows alarm to be rung in case the door lock is manipulated from the inside.
And it makes difficultly to open through Thumbturn Lever.
① Touch the [Touchscreen].
② Press the [#] button for 3 seconds.
③ Enter the PIN Code and press the [*] button.
12. Lockout Mode
When more than 5 failed authentication attempts with unregistered PIN Code/Cards occur,
the alarm sound is generated, and the lock is deactivated for 3 minutes.
13. Intrusion Detection Function
When the Interior Unit is forcibly detached while the door is locked, it is detected by the
magnetic sensor, the alarm sounds. The Intrution Detection function is a basic function and
cannot be disabled.
14. Addtional Function Mode
SET
Volume Setting
Locking Mode
Random
Security Mode
Double Authori-
zation Mode
Local
Setting
Time
Silent
Low
High
Auto lock 2sec
Auto lock 5sec
Auto lock 10sec
Manual lock
2 Digits
4 Digits
6 Digits
Disable
Enable
Disable
YYMMDDHHMM
NOTE: THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV
INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT.
SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE
EQUIPMENT.
FCC RF Radiation Exposure Statement:
This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with a minimum distance of
20 cm between the radiator and your body. This transmitter must not be co-located or
operating in conjunction with any other antenna or transmitter.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : hwj
Create Date                     : 2015:03:25 20:35:20+09:00
Modify Date                     : 2015:03:27 10:57:21+09:00
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Producer                        : Acrobat Distiller 11.0 (Windows)
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2015:03:27 10:57:21+09:00
Format                          : application/pdf
Title                           : Microsoft Word - manual_english_365plus_.doc
Creator                         : hwj
Document ID                     : uuid:78a1468f-6ebb-450c-aeed-3cd474726800
Instance ID                     : uuid:24e42a6a-a096-4aca-8d4f-a1d8a5d3fdf0
Page Count                      : 7
EXIF Metadata provided by EXIF.tools
FCC ID Filing: P4Y365PLUS

Navigation menu