Sanyo Electric Co PBS-CS37 The Radio Cell Station for PHS WLL System User Manual

Sanyo Electric Co Ltd The Radio Cell Station for PHS WLL System

Users manual

SANYOPHS Cell StationSep 12, 2002- User’s Manual -
1Table of ContentsTable of contents ............................................................................................................................. 1Installation conditions  ................................................................................................................. 2,3Fixing antenna for PBS-CS37 ........................................................................................................ 4Condition of the antenna cable (PBS-CS37)  ................................................................................ 5Terminal block appearance ............................................................................................................ 6Notes at the time of lid opening and closing ................................................................................. 7Connection of the power cable .................................................................................................... 8,9Connection of the line cable .................................................................................................... 11,12Concerning the installation of cable ............................................................................................ 13Warning ......................................................................................................................................... 14Appendix (1), (2) ...................................................................................................................... 15,16
2Installation conditions]Place\CS shall be installed in the place where the public can not easily access.\Installation place shall have the structure which can support the weight of CSand its fixing facilities.\Installation place shall be flat with no inclination.\If CS is installed in the place where it may drop down, it shall be providedwith protective measure against the drop.\There shall be no object around 2m of CS.\For the maintenance use, there shall be the space in about 500mm around thestand.\CS shall be installed in the direction that the logo plate appears upwards. CScan be placed in vertical direction with arranging the fixing metal.
3Installation conditions]Antenna\With fixing antennas, there shall be enough viewing angle from CS. (Targetangle: vertical: 30 degree or more, horizontal: 330 degree or more)]ISDN Line\Interconnection box for ISDN line shall be available near the CS.\ISDN line length from the exchange to CS and its quality shall comply withthe technical standard (ANSI T1.601-1992).]Power supply\AC120V shall be available with easy wiring connection work.
4Fixing antenna for PBS-CS37To ISDN LineAC120VMDFBreakerPBS-CS37
5Connection of the antenna cable(PBS-CS37)]Numbering arrangement\Numbering arrangement of 1 - 4 shall be madeclockwise or counterclockwise.]Tightening torque of the antenna cable:7 - 12 Kgf-cm.]Wind the self-bonding tape between theantenna connector and the end of cable.1234Upper sideantenna1234Upper sideantennaCase of ClockwiseCase of Counterclockwise
6Terminal block appearance(PBS-CS37)]Terminal block of the power supply and line’s connections are shown below1: Status indications LED Label2: Reset Switch3: Maintenance terminal connector4: Status indications LED5,10: Line check terminal connector6,9: Line terminal connector7,8: Line Status LED11: Power supply Terminal(N)12: GND Terminal(FG)13: Power supply Terminal(L)14: Earth clamp for Power cable15: Cable gland for power cable16: Cable gland for Line cable17: Earth clamp for Line cable18: GPS indications label for GPS model
7Notes at the time oflid opening and closing]Opening\After loosening all lid’s fixation screws completely, pullupper part and central screw of the lid, and slide. (Photo1)\Confirm that all screws are free completely and two pins ofthe lid is at the right edge of two metal fittings ,thereforerotate the lid while pulling in the direction”an arrow” likebelow . (Photo2)]Closing\Tightening torque of Cap screw: 10 - 15 Kgf-cm\Tighten with M4 hexagon Socket Cap screws. (Cap screw).\Tighten 6 screws equally and well balanced, after confirmingthat the waterproof packing is nonexistent between the lidand the CS.[Caution1] If the clamp face or waterproof packing is scarredby screw’s cusp, the waterproof performance may not beobtained.[Caution 2] Photos of PBS-CS47 are used for explanations inthis User’s Manual.(Photo1)(Photo2)
8Connection of the power cable (1)1) Reeve the cable from the cable gland nutinto the lid.2) Pull the cable out to enough length thatthe tip of the cable can be processed.3) Peel the covering of the cable. (Photo 3)4) Peeling off core line.5) Loosen the copper shield and wind itonto the core wire’s tip 4 turns or more. (Photo3)CoppershieldCoveringendCovering70 - 90mminterposition material: Cut it at the covering’ root.(figure)8 - 9mm60 - 80mm15mmCopper shield*The cable color is generally used in Japan, and itused in U.S.A. shall comply with the localspecifications.
9Connection of the power cable (2)6) Feazings processing of the core line.\Push the upper part of the connector with afinger, and insert a core wire. (figure)\L (Loading), N (Neutral), FG (Frame Ground).7) Combine the copper shield to the position“FIX” of Photo 5. And tighten the cablegland firmly.\[Caution]When the fixation of the terminalblock’s lid is imperfect, it is feared that thisCS gives hindrance to other electric devices.8) Form core wires that are inserted into thepower supply terminal.9) The tightening of the dome nut must bedone by hand without fail and tighten itstrongly.10) Wind the self-bonding tape between thesurface of dome nut and the end of cable.(figure)N:White FG:Red L:BlackFixForming(photo5)
10Connection of the Line cable (1)1) Reeve the cable from the dome nut intothe lid.2) Pull the line cable out to enough lengththat the tip of the cable can beprocessed.3) Peeling of the line cable covering.     (Photo 6)\Peel off the covering of the line cable. Thelength of the line cable is 100 - 120 mm.(Photo 6)4) Loosen the shield and wind it on theheart line of covering 4 turns or more.(Photo 7)\Loosen these four pair lines, plug in thedesignated touching sockets.(photo6)(photo7)Shield tapeDrain wireCovering100 - 120mmWind the aluminum shield, andfurthermore wind drain wire here too.Process the end of the line wire, which arenot used, with the suiting tape.
11Connection of the Line cable (2)5) Loosen these four pair lines, plug in thedesignated touching sockets.6) Combine the copper shield to theposition where is located in the arrowof Photo 8 below. And tighten thecable gland firmly.7) Plug four touching sockets to     the connector on the PWB in the     terminal block. (Photo8)(Figure)(photo8)  Before touchingBefore touching After touchingAfter touchingPair lines Touching socket TouchingscrewLA LB LC LCGround clamp for the Line
12Connection of the Line cable (3)8) Form core wires that are inserted into the lineconnector.\Form the line cable as not touching on the block.      (Photo 9)\Pay attention that the line cable does not touch      on the packing .9) Tighten the dome nut.10) Wind the self-bonding tape between the surface        of dome nut and the end of cable.(photo9)
13Concerning the installation of cables]Ground earth terminal of the power cable securelyIn case that ground does not executed, there is the possibility that destroys the CS.Because the surge protection by the ground wire can not perform.]The earthing less than 10ohm (Class A) is desirable.There is the possibility that the obstacle occurs to sounds and pictures of otherradio devices, when the earthing resistance becomes high.]Separation distance between cablesDistance (generally 20 cm or more) shall be kept between the line cable and thepower cable for secure installation.]The shield processing of the cable  (maintenance box & breaker box)Earthing must be executed as for the breaker box.]Installation of lightening facilitySpecifications of the CS do not specify the requirement for the installation oflightning conductor. Don't connect the lightning cable to FG of the powersupply.
14WARNING!FCC RF EXPOSURE COMPLIENCE]This cell station has been tested and complies with the FederalCommunications Commission (FCC) RF exposure limits for GeneralPopulation/Uncontrolled exposure environment.]The design of this cell station complies with the FCC guidelinesand these international standards. This cell station complies with theMPE requirements by providing a minimum save-distance between theantenna and any persons. Please keep the minimum save-distance of 1.15meters from the cell station .]Unauthorized alteration, modifications or attachments couldimpair its quality, damage the cell station, or result in violationof FCC regulations.
15Appendix1:Installation materials (for example)]Materials        Quantity                PBS-CS37Antenna 4Coaxial cable (upper) 4Coaxial cable (lower) -Power supply cable 1Line cable 2pairLine connector 2Stand 1setAntenna pole 1Antenna Arm 4Arm fixing block(upper) 1Arm fixing block(lower) -Self-bonding tape        as adequateTie band        as adequate
16Appendix2:Cable specificationsKinds Usage Specifications RemarksCoaxial cable Antenna -PHS cellstation8D-SFA (connector with one-side N style (P))MAX: 6m Accessory ofthe antennaPower cable PHS cellstation -powersupplybreaker boxWith the 2.0mm2 , 3 cores with the copper shieldtapeOutsize diameter : 9.5 – 13 Ø   Frameresisting: PE cableThe color is designated.(black, white, green and red)Power cablethe equivalentfor the existingcell stationLine cable Cell station -MaintenanceboxSingle line: Ø 0.5mm-4 pairsA category 4 or more with aluminum or coppershield tape(Shield material 0.05t over)Outsize diameter : 6 – 8 ØFlame resisting: PE cableLine cableThe equivalentFor the existingcell station