The Ideal –152˚C, –86˚C Freezing Environment in Capacities from 86 L to 701 L Ideal for long term preservation of biologicals, blood components and various cell line, SANYO preservation systems employ microprocessor control to maintain a high-precision temperature environment. They are not affected by ambient temperature, minimizing uneven temperature distribution within the chamber, and a temperature rise during door opening. –152˚C Ultra-Low Temperature Chest Freezer For stable long-term storage MDF-1156/1156ATN TEMPERATURE EFFECTIVE CAPACITY –152˚C 128 L (4.5 ) cu.ft. Dimensions Unit: mm (inch) 905 (35.6) 1400 (55.1) 52 (2.0) 450 (17.7) 667 (26.3) 945 (37.2) 500 (19.7) 572 (22.5) 800 (31.5) 53 (2.1) 105 (4.1) MDF-1156 Performance Data Pull-down characteristics under no-load condition 0 –20 –40 –60 –80 –100 –120 –140 –160 Effect of ambient temp. on holding time of liquefied gas 25 LN2 injection at –135˚C 0 5 10 15 Time (hr.) 20 25 Time (hr.) Temp. (˚C) Central air temp. in cabinet Ambient temp. 30˚C, no load Temp. (˚C) 60 40 20 0 –20 –40 –60 –80 –100 –120 –140 –160 Pull-up characteristics during power failure 20 15 Central air temp. in cabinet Ambient temp. 30˚C, no load 0 1 2 3 4 5 Time (hr.) 6 7 8 SV of backup system –135˚C LN2 50L 9 0 0 10 20 30 Ambient temp. (˚C) 40 For MDF-1156/1156ATN Why Freeze to –152˚C? Recrystallization Mechanism (Artist’s Concept) Hexagonal crystal –80˚C Cubic crystal –130˚C Recrystallization point –152˚C Advanced Features Specially designed compressor and cascade refrigeration system Specially designed for rugged ultra-low temperature applications in a laboratory environment (HFC refrigerants only). An important factor to consider when preserving cells or tissue at ultra-low temperatures is to prevent amorphous ice crystals from recrystallizing within and outside the cells. Samples that are maintained in an ultra-low temperature freezer at –152˚C which is far lower than the recrystallization point (–130˚C for pure water) can be preserved semi-permanently. Preservation at ultra-low temperatures maintains vitrification without crystallization occurring inside and outside cells. In contrast to conventional liquid nitrogen preservation containers, freezer preservation has numerous advantages: no sample contamination, no sudden liquid eruptions, as well as low operational costs. SANYO’s MDF-1156 and 1156ATN make long-term storage below the recrystallization point easier and more stable than ever before. The temperature sensor, filter sensor and cascade sensor monitor operation conditions continuously. Should abnormality be picked up, an error code and the current temperature will be displayed in turn. Ring back function The alarm buzzer can be silenced by pressing the BUZZER key on the control panel. (The remote alarm signal is not cancelled.) Should the alarm condition continue after a certain suspension, the alarm buzzer sound will resume. Amorphous ice crystal World’s lowest –152˚C freezer ensures stable cell and tissue preservation Self-diagnostic function Micro-processor Temperature Control with LED Digital Display Extremely accurate, easy-to-read display. The temperature inside the freezer can be set and monitored easily by means of a microprocessor temperature control with an LED digital display. The thermostat incorporates a platinum resistor (Pt. 100Ω), precision and durability. Integrated Cabinet Design High-performance refrigeration system with foamed-in-place cabinet insulation maximizes interior temperature uniformity and protects against fluctuating ambient temperatures. Hot line for secure sealing Moisture condensation at the top edges of the cabinet due to differences in temperature inside and out causes frost and icing problems that may reduce heat insulation efficiency and obstruct door movements. These problems are prevented by the “hot line” by means of which hot gas from the higher temperature circuit is circulated through the problem areas. Hot line Easy Maintenance (MDF-193/193AT have no filters) Filter check lamp notifys the user of a clogged condenser filter.The condenser filter is situated at the front panel to make filter removing and cleaning easier. Note: The position of the filter check lamp is shown on the control panel (see photo shown at the bottom of this page). Standard casters and levelling feet Standard-equipped heavy duty casters make it easy to move a freezer when necessary. The levelling feet keep a freezer level and firm on the floor. Safety Device Built-In Temperature & Power Failure Alarms (Lamp/Buzzer) In case of power failure or an irregular rise in temperature, a rechargeable battery-operated indicator lamp and alarm will be activated. A compact recording unit which automatically records the inside temperature, and a backup system with liquefied CO2 or N2 which is selfactivated when a power outage occurs are also available separately. This equipment helps insure that the contents will be protected in the event of any power failure or mechanical trouble. Control panel 1 Alarm lamp and buzzer 2 Filter check lamp 3 Buzzer key 1 2 4 Alarm test key 5 Mode setting key 3 4 5 6 6 Digit shift key 7 7 Numerical value shift key 8 Power switch 9 12 8 9 CO2 back-up test swich (AT type only) 10 11 10 CO2 back-up swich (AT type only) 11 Battery switch 12 Temperature recorder MDF-394AT –86˚C Ultra-Low Temperature Chest Freezers Ideal for large-capacity preservation MDF-794/794AT TEMPERATURE EFFECTIVE CAPACITY –86˚C 701 L (24.8 ) cu.ft. Dimensions Unit: mm (inch) 2570 (101.2) 861 (33.9) 770 (30.3) 53 (2.1) 1070 (42.1) 795 (31.3) 762 (30) 2110 (83.1) 1840 (72.4) 38 (1.5) MDF-794AT 500 (19.7) 105 (4.1) Performance Data Central air temp. in cabinet Ambient temp. 30˚C, no load 0 1 2 3 4 5 6 7 8 9 10 30 20 10 0 –10 –20 –30 –40 –50 –60 –70 –80 –90 Effect of ambient temp. on holding time of liquefied gas 20 Central air temp. in cabinet Ambient temp. 30˚C, no load SV of backup system –70˚C LCO2 30kg Time (hr.) 30 20 10 0 –10 –20 –30 –40 –50 –60 –70 –80 –90 Pull-up characteristics during power failure Temp. (˚C) Temp. (˚C) Pull-down characteristics under no-load condition 0 1 2 3 4 Time (hr.) 5 6 7 8 9 15 10 5 10 5 10 15 20 25 30 35 Ambient temp. (˚C) Time (hr.) Ideal for middle-sized installation space MDF-594/594AT TEMPERATURE EFFECTIVE CAPACITY –86˚C 487 L (17.1 ) cu.ft. Dimensions 861 (33.9) Unit: mm (inch) 2010 (79.1) 53 (2.1) 1070 (42.1) 795 (31.3) 762 (30) 1550 (61.0) 1280 (50.4) 770 (30.3) 38 (1.5) MDF-594AT 500 (19.7) 105 (4.1) Performance Data Central air temp. in cabinet Ambient temp. 30˚C, no load 0 1 2 3 4 5 6 Time (hr.) 7 8 9 10 30 20 10 0 –10 –20 –30 –40 –50 –60 –70 –80 –90 Effect of ambient temp. on holding time of liquefied gas 20 Central air temp. in cabinet Ambient temp. 30˚C, no load SV of backup system –70˚C LCO2 30kg Time (hr.) 30 20 10 0 –10 –20 –30 –40 –50 –60 –70 –80 –90 Pull-up characteristics during power failure Temp. (˚C) Temp. (˚C) Pull-down characteristics under no-load condition 0 1 2 3 4 5 6 Time (hr.) 7 8 9 10 15 10 5 5 10 15 20 25 Ambient temp. (˚C) 30 35 Low-profile design for easy access to stored materials MDF-394 TEMPERATURE EFFECTIVE CAPACITY –86˚C 309 L (10.9 ) cu.ft. Dimensions Unit: mm (inch) 891 (35.1) 1860 (73.2) 53 (2.1) 945 (37.2) 660 (26.0) 530 (20.9) 1400 (55.1) 1120 (44.1) 800 (31.5) 38 (1.5) 520 (20.5) MDF-394 105 (4.1) Performance Data Central air temp. in cabinet Ambient temp. 30˚C, no load 0 1 2 3 4 5 6 7 8 9 10 30 20 10 0 –10 –20 –30 –40 –50 –60 –70 –80 –90 Effect of ambient temp. on holding time of liquefied gas 20 SV of backup system –70˚C LCO2 30kg Time (hr.) 30 20 10 0 –10 –20 –30 –40 –50 –60 –70 –80 –90 Pull-up characteristics during power failure Temp. (˚C) Temp. (˚C) Pull-down characteristics under no-load condition 15 10 Central air temp. in cabinet Ambient temp. 30˚C, no load 0 1 2 3 Time (hr.) 4 5 6 7 8 9 5 10 5 10 Time (hr.) 15 20 25 30 35 Ambient temp. (˚C) Compact, space-saving unit optimized for private use MDF-193/193AT TEMPERATURE EFFECTIVE CAPACITY –86˚C 86 L (3.0 ) cu.ft. Unit: mm (inch) 750 (29.5) 791 (31.1) 700 (27.6) 658 (25.9) 945 (37.2) 53 (2.1) 38 (1.5) 420 (16.5) Dimensions MDF-193 480 (18.9) 430 (16.9) Performance Data 30 20 10 Central air temp. in cabinet Ambient temp. 30˚C, no load 0 1 2 3 4 5 6 Time (hr.) 7 8 9 Effect of ambient temp. on holding time of liquefied gas 10 –10 –20 –30 –40 –50 –60 –70 –80 –90 20 Time (hr.) 30 20 10 0 –10 –20 –30 –40 –50 –60 –70 –80 –90 Pull-up characteristics during power failure Temp. (˚C) Temp. (˚C) Pull-down characteristics under no-load condition 15 10 Central air temp. in cabinet Ambient temp. 30˚C, no load 0 1 2 3 4 5 6 Time (hr.) 7 8 9 SV of backup system –70˚C LCO2 30kg 10 5 5 10 15 20 25 Ambient temp. (˚C) 30 35 Specifications MDF-394* MDF-594/594AT MDF-193/193AT –50˚C to –86˚C 2,570 x 770 x 1,070 1,860 x 800 x 945 2,010 x 770 x 1,070 750 x 700 x 945 (101.2 x 30.3 x 42.1) (73.2 x 31.5 x 37.2) (79.1 x 30.3 x 42.1) (29.5 x 27.6 x 37.2) 1,840 x 500 x 762 1,120 x 520 x 530 1,280 x 500 x 762 480 x 430 x 420 (72.4 x 19.7 x 30.0) (44.1 x 20.5 x 20.9) (50.4 x 19.7 x 30.0) (18.9 x 16.9 x 16.5) 701 liters (24.8 cu.ft.) 309 liters (10.9 cu.ft.) 487 liters (17.1 cu.ft.) 86 liters (3.0 cu.ft.) Galvanised steel with baked on finish Stainless steel Aluminum plate 3 4 1 1 Foamed-in-place rigid polyurethane Hermetic type, 1,100 W Hermetic type, 450 W Hermetic reciprocated type, Hermetic type, 1,100 W Hermetic type, 750 W 450 W Cascade condenser Tube-on-sheet type Tube on sheet (shared with interior) Fin and tube type Fin and tube type Finless tube type Shell and tube type Cascade condenser Cascade condenser Microprocessor: Keypad input Microprocessor Temp. input range: –20˚C to –95˚C (1˚C increment) control system, Set value memory: non-volatile memory Non-volatile memory Digital display Platinum resistance (Pt. 100 Ω) Platinum resistance (Pt. 1000 Ω) Cylinder key on the lid handle and Mouse proof cover on the back side Adjustable high and low temp. alarm Selectable high temp. alarm (+10˚C & +15˚C from set point) (±5˚C to ±20˚C from set point) Power failure alarm, Filter check lamp (Except MDF-193/193AT which have no filters), Remote alarm contact Model No. Temperature Range Exterior Dimensions [W x D x H] mm (inch) Interior Dimensions [W x D x H] mm (inch) Effective Capacity Exterior Cabinet Interior Cabinet Inner Lid Insulation High stage side Compressor Low stage side High stage side Evaporator Low stage side High stage side Condenser Low stage side MDF-1156/1156ATN –125˚C to –152˚C 1,400 x 800 x 945 (55.1 x 31.5 x 37.2) 500 x 450 x 572 (19.7 x 17.7 x 22.5) 128 liters (4.5 cu.ft.) MDF-794/794AT 265kg (584 lbs.) —1156 272kg (600 lbs.) —1156ATN 335kg (739 lbs.) —794 345kg (761 lbs.) —794AT Temperature Control Temperature Display Sensor Safety Alarm system Net Weight (Approx.) 291kg (642 lbs.) —594 301kg (664 lbs.) —594AT 103kg (227 lbs.) —193 109kg (240 lbs.) —193AT 219kg (483 lbs.) ATN: LN2 backup system, temperature recorder AT: LCO2 backup system, temperature recorder *MDF-394 for 110 to115V and 220V/60Hz is unavailable. Optional Accessories Storage Racks (Aluminium) Temperature Recorder Model No. MDF-19SC MDF-39SC MDF-49SC MDF-59SC Case Dimensions (W x D x H) Number of Drawers Applicable Model (Rack capacity) 207 x 144 x 413mm 8.1” x 5.7” x 16.3” 3 155 x 155 x 515mm 6.1” x 6.1” x 20.3” 4 207 x 144 x 539mm 8.1” x 5.7” x 21.2” 4 MDF-193/193AT (6) MDF-394 (20) 207 x 144 x 665mm 8.1” x 5.7” x 26.2” 5 MDF-594/594AT (18) MDF-1156/1156ATN (6) MDF-794/794AT (24) Inventory Racks (Stainless steel) Model No. MTR-85H MTR-155H Recording Range –100 to +50˚C –170 to +30˚C MDF-193 MDF-394 MDF-594 MDF-794 MDF-1156 Freezer Model ULT-Freezer Backup Kits Box Type External Dimensions (mm) Freezer Model (Rack capacity) Model No. (Capacity) Width Depth Height IR-207C 2” (7) 144 142 405 MDF-193 (6) IR-209C 2” (9) 144 142 518 MDF-394 (21), 1156 (9) IR-213C 2” (13) 144 142 592 MDF-594 (24), 794 (36) IR-305C 3” (5) 144 142 405 MDF-193 (6) IR-306C 3” (6) 144 142 518 MDF-394 (21), 1156 (9) IR-309C 3” (9) 144 142 747 MDF-594 (24), 794 (36) CVK-UB2/UB2(I): LCO2 Backup Kit for MDF-794/594/394 CVK-UBN2/UBN2(I): LN2 Backup Kit for MDF-794/594/394 CVK-A: Built-in LCO2 Backup Kit for MDF-794/594/394/193 CVK-AT2: LCO2 Backup Kit for MDF-1156 CVK-ATN2: LN2 Backup Kit for MDF-1156 IR-209C IR-306C MDF-39SC MDF-59SC (I) version for North America only *Cooling performance is indicated by the temperature reached at the center of the freezer (at ambient temperature of 30°C with no load). In order to use the freezer at a stable temperature for a long time, it is recommended that the temperature be set to at least 5°C higher than the indicated lowest temperature. In addition, depending on the usage conditions, it may not be possible to reach the indicated lowest temperature. Caution: SANYO guarantees the product under certain warranty conditions. SANYO in no way shall be responsible for any loss of content or damage to content. • Appearance and specifications are subject to change without notice. SANYO Electric Co., Ltd., Biomedical Division, Gunma is certified for: Quality management system: ISO9001 / Medical devices quality management system: ISO13485 / Environmental management system: ISO14001 RoHS (European Restriction of Hazardous Substances directives) compliant Distributed by: SANYO Electric Co., Ltd. Biomedical Division http://www.sanyo.co.jp/cmg/biomedical ©2008 SANYO Printed in Japan 2008.12 MA SHR141
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Create Date : 2008:12:16 18:51:42 Producer : Acrobat Distiller 4.05 for Macintosh Author : wakafuji miharu Creator : Adobe Illustrator(R) X Title : ULT_chest_.eps Modify Date : 2008:12:16 18:52:28+09:00 Page Count : 6EXIF Metadata provided by EXIF.tools