Performance Data
Pull-down characteristics
under no-load condition
Pull-up characteristics
during power failure
TEMPERATURE EFFECTIVE CAPACITY
–152˚C 128 L (4.5cu.ft.)
Dimensions Unit: mm (inch)
MDF-1156/1156ATN
Ideal for long term preservation of biologicals, blood components and various
cell line, SANYO preservation systems employ microprocessor control to
maintain a high-precision temperature environment. They are not affected by
ambient temperature, minimizing uneven temperature distribution within the
chamber, and a temperature rise during door opening.
The Ideal –152˚C, –86˚C Freezing Environment
in Capacities from 86 L to 701 L
500 (19.7)
572 (22.5)
667 (26.3)
1400 (55.1)
450 (17.7)
52
(2.0)
105
(4.1)
53
(2.1)
905 (35.6)
800 (31.5)
945 (37.2)
0252015105
Time (hr.)
Temp. (˚C)
–160
–40
–120
–20
–140
–80
–100
–60
0
20
40
60
0 567394281
Time (hr.)
Temp. (˚C)
–160
Central air temp. in cabinet
Ambient temp. 30˚C, no load
For stable long-term storage
0
15
20
25
Ambient temp. (˚C)
Time (hr.)
04010 3020
Effect of ambient temp.
on holding time of liquefied gas
–152˚C Ultra-Low Temperature Chest Freezer
LN2 injection at –135˚C
MDF-1156
SV of backup system –135˚C
LN2 50L
–140
–120
–100
–80
–60
–40
–20
0
Central air temp. in cabinet
Ambient temp. 30˚C, no load
–80˚C
–130˚C
–152˚C
Recrystallization point
Hexagonal crystal
Cubic crystal
Amorphous
ice crystal
Why Freeze to –152˚C?
Recrystallization Mechanism (Artist’s Concept)
World’s lowest –152˚C freezer
ensures stable cell and tissue
preservation
An important factor to consider when
preserving cells or tissue at ultra-low
temperatures is to prevent amorphous ice
crystals from recrystallizing within and
outside the cells. Samples that are
maintained in an ultra-low temperature
freezer at –152˚C which is far lower than the
recrystallization point (–130˚C for pure water)
can be preserved semi-permanently.
Preservation at ultra-low temperatures
maintains vitrification without crystallization
occurring inside and outside cells.
In contrast to conventional liquid nitrogen
preservation containers, freezer preservation
has numerous advantages: no sample
contamination, no sudden liquid eruptions,
as well as low operational costs.
SANYO’s MDF-1156 and 1156ATN make
long-term storage below the recrystallization
point easier and more stable than ever
before. Built-In Temperature & Power
Failure Alarms (Lamp/Buzzer)
In case of power failure or an irregular rise in
temperature, a rechargeable battery-operat-
ed indicator lamp and alarm will be activat-
ed. A compact recording unit which auto-
matically records the inside temperature,
and a backup system with liquefied CO2 or
N2 which is selfactivated when a power out-
age occurs are also available separately. This
equipment helps insure that the contents
will be protected in the event of any power
failure or mechanical trouble.
For MDF-1156/1156ATN
Safety Device
Advanced Features
Alarm lamp and buzzer
Filter check lamp
Buzzer key
Alarm test key
Mode setting key
Digit shift key
Numerical value shift key
Power switch
CO2 back-up test swich (AT type only)
CO2 back-up swich (AT type only)
Battery switch
Temperature recorder
Control panel
Hot line
Standard casters and levelling feet
Standard-equipped heavy duty casters make
it easy to move a freezer when necessary.
The levelling feet keep a freezer level and
firm on the floor.
Self-diagnostic function
The temperature sensor, filter sensor and
cascade sensor monitor operation conditions
continuously. Should abnormality be picked
up, an error code and the current tempera-
ture will be displayed in turn.
Ring back function
The alarm buzzer can be silenced by press-
ing the BUZZER key on the control panel.
(The remote alarm signal is not cancelled.)
Should the alarm condition continue after a
certain suspension, the alarm buzzer sound
will resume.
Easy Maintenance (MDF-193/193AT have
no filters)
Filter check lamp notifys
the user of a clogged
condenser filter.The
condenser filter is situat-
ed at the front panel to
make filter removing
and cleaning easier.
Note: The position of the filter check lamp is shown
on the control panel (see photo shown at the
bottom of this page).
MDF-394AT
1
2
3 4 5 6 7
8
9
10
12 11
1
2
3
4
5
6
7
8
9
10
12
11
Specially designed compressor and
cascade refrigeration system
Specially designed
for rugged ultra-low
temperature
applications in a
laboratory
environment (HFC
refrigerants only).
Micro-processor Temperature
Control with LED Digital Display
Extremely accurate, easy-to-read display.
The temperature inside the freezer can be
set and monitored easily by means of a
microprocessor temperature control with an
LED digital display. The thermostat
incorporates a platinum resistor (Pt. 100),
precision and durability.
Integrated Cabinet Design
High-performance refrigeration system with
foamed-in-place cabinet insulation
maximizes interior temperature uniformity
and protects against fluctuating ambient
temperatures.
Hot line for secure sealing
Moisture condensation at the top edges of
the cabinet due to differences in tempera-
ture inside and out causes frost and icing
problems that may reduce heat insulation
efficiency and obstruct door movements.
These problems are prevented by the “hot
line” by means of which hot gas from the
higher temperature circuit is circulated
through the problem areas.
TEMPERATURE EFFECTIVE CAPACITY
–86˚C 701 L (24.8cu.ft.)
TEMPERATURE EFFECTIVE CAPACITY
–86˚C 487 L (17.1cu.ft.)
Performance Data
Pull-down characteristics
under no-load condition
Pull-up characteristics
during power failure
Effect of ambient temp.
on holding time of liquefied gas
Performance Data
Pull-down characteristics
under no-load condition
Effect of ambient temp.
on holding time of liquefied gas
Dimensions Unit: mm (inch)
Dimensions Unit: mm (inch)
Pull-up characteristics
during power failure
Ideal for large-capacity preservation
MDF-794/794AT
Ideal for middle-sized installation space
MDF-594/594AT
5
10
15
20
Ambient temp. (˚C)
Time (hr.)
53515 2510 3020
5
10
15
20
Ambient temp. (˚C)
Time (hr.)
53515 2510 3020
–86˚C Ultra-Low Temperature Chest Freezers
1280 (50.4)
762 (30)
795 (31.3)
1550 (61.0)
2010 (79.1)
500 (19.7)
53
(2.1)
770 (30.3) 38 (1.5)
861 (33.9)
105 (4.1)
1070 (42.1)
MDF-794AT
MDF-594AT
SV of backup system –70˚C
LCO2 30kg
SV of backup system –70˚C
LCO2 30kg
012345678910
Time (hr.)
Temp. (˚C)
–90
–10
–30
–70
–20
–80
–50
–60
–40
0
10
20
30
Central air temp. in cabinet
Ambient temp. 30˚C, no load
012345678910
Time (hr.)
Temp. (˚C)
–90
–10
–30
–70
–20
–80
–50
–60
–40
0
10
20
30
Central air temp. in cabinet
Ambient temp. 30˚C, no load
012345678910
Time (hr.)
Temp. (˚C)
–90
–10
–30
–70
–20
–80
–50
–60
–40
0
10
20
30
Central air temp. in cabinet
Ambient temp. 30˚C, no load
012345678910
Time (hr.)
Temp. (˚C)
–90
–10
–30
–70
–20
–80
–50
–60
–40
0
10
20
30
Central air temp. in cabinet
Ambient temp. 30˚C, no load
2570 (101.2)
2110 (83.1)
795 (31.3)
1840 (72.4)
762 (30)
500 (19.7)
53
(2.1)
770 (30.3) 38
(1.5)
861 (33.9)
105 (4.1)
1070 (42.1)
TEMPERATURE EFFECTIVE CAPACITY
–86˚C 309 L (10.9cu.ft.)
TEMPERATURE EFFECTIVE CAPACITY
–86˚C 86 L (3.0cu.ft.)
Performance Data
Pull-down characteristics
under no-load condition
Effect of ambient temp.
on holding time of liquefied gas
Performance Data
Pull-down characteristics
under no-load condition
Pull-up characteristics
during power failure
Effect of ambient temp.
on holding time of liquefied gas
Dimensions Unit: mm (inch)
Dimensions Unit: mm (inch)
MDF-394
Low-profile design for easy access to stored materials
MDF-193/193AT
Compact, space-saving unit optimized for private use
Pull-up characteristics
during power failure
5
10
15
20
Ambient temp. (˚C)
Time (hr.)
53515 2510 3020012345678910
Time (hr.)
Temp. (˚C)
–90
–10
–30
–70
–20
–80
–50
–60
–40
0
10
20
30
Central air temp. in cabinet
Ambient temp. 30˚C, no load
012345678910
Time (hr.)
Temp. (˚C)
–90
–10
–30
–70
–20
–80
–50
–60
–40
0
10
20
30
Central air temp. in cabinet
Ambient temp. 30˚C, no load
480 (18.9)
750 (29.5)
658 (25.9)
430 (16.9)
945 (37.2)
420 (16.5)
53
(2.1)
700 (27.6) 38 (1.5)
791 (31.1)
MDF-394
MDF-193
SV of backup system –70˚C
LCO2 30kg
5 101520253035
5
10
15
20
Time (hr.)
Ambient temp. (˚C)
SV of backup system –70˚C
LCO2 30kg
012345678910
Time (hr.)
Temp. (˚C)
–90
–10
–30
–70
–20
–80
–50
–60
–40
0
10
20
30
Central air temp. in cabinet
Ambient temp. 30˚C, no load
012345678910
Time (hr.)
Temp. (˚C)
–90
–10
–30
–70
–20
–80
–50
–60
–40
10
20
30
Central air temp. in cabinet
Ambient temp. 30˚C, no load
660 (26.0)
1400 (55.1)
1860 (73.2)
1120 (44.1)
530 (20.9)
105 (4.1)
945 (37.2)
53
(2.1)
800 (31.5) 38 (1.5)
891 (35.1)
520 (20.5)
Distributed by:
SANYO Electric Co., Ltd.
Biomedical Division
http://www.sanyo.co.jp/cmg/biomedical
©2008 SANYO Printed in Japan 2008.12 MA
SHR141
SANYO Electric Co., Ltd., Biomedical Division, Gunma is certified for:
Quality management system: ISO9001 / Medical devices quality management system: ISO13485 / Environmental management system: ISO14001
RoHS (European Restriction of Hazardous Substances directives) compliant
Specifications
Optional Accessories
Model No.
IR-207C
IR-209C
IR-213C
IR-305C
IR-306C
IR-309C
Model No.
Case Dimensions
(W x D x H)
Number of Drawers
Applicable Model
(Rack capacity)
Model No.
Recording
Range
Freezer
Model
MDF-19SC
207 x 144 x 413mm
8.1” x 5.7” x 16.3”
3
MDF-193/193AT (6)
MTR-85H
–100 to +50˚C
MDF-193
MDF-394
MDF-594
MDF-794
MTR-155H
–170 to +30˚C
MDF-1156
MDF-39SC
155 x 155 x 515mm
6.1” x 6.1” x 20.3”
4
MDF-394 (20)
MDF-49SC
207 x 144 x 539mm
8.1” x 5.7” x 21.2”
4
MDF-1156/1156ATN (6)
MDF-59SC
207 x 144 x 665mm
8.1” x 5.7” x 26.2”
5
MDF-594/594AT (18)
MDF-794/794AT (24)
Box Type
(Capacity)
2” (7)
2” (9)
2” (13)
3” (5)
3” (6)
3” (9)
Width
144
144
144
144
144
144
Depth
142
142
142
142
142
142
Height
405
518
592
405
518
747
Freezer Model (Rack capacity)
MDF-193 (6)
MDF-394 (21), 1156 (9)
MDF-594 (24), 794 (36)
MDF-193 (6)
MDF-394 (21), 1156 (9)
MDF-594 (24), 794 (36)
External Dimensions (mm)
ULT-Freezer Backup Kits
CVK-UB2/UB2(I):
LCO2 Backup Kit for MDF-794/594/394
CVK-UBN2/UBN2(I):
LN2 Backup Kit for MDF-794/594/394
CVK-A: Built-in LCO2 Backup Kit
for MDF-794/594/394/193
CVK-AT2: LCO2 Backup Kit for MDF-1156
CVK-ATN2: LN2 Backup Kit for MDF-1156
IR-306CIR-209C
Storage Racks (Aluminium) Temperature Recorder
Inventory Racks (Stainless steel)
MDF-39SC
Model No.
Temperature Range
Exterior Dimensions
[W x D x H] mm (inch)
Interior Dimensions
[W x D x H] mm (inch)
Effective Capacity
Exterior Cabinet
Interior Cabinet
Inner Lid
Insulation
High stage side
Low stage side
High stage side
Low stage side
High stage side
Low stage side
Temperature Control
Temperature Display
Sensor
Safety
Alarm system
Net Weight (Approx.)
MDF-193/193AT
750 x 700 x 945
(29.5 x 27.6 x 37.2)
480 x 430 x 420
(18.9 x 16.9 x 16.5)
86 liters (3.0 cu.ft.)
1
Hermetic reciprocated type,
450 W
Tube-on-sheet type
Finless tube type
Platinum resistance (Pt. 100 )
103kg (227 lbs.) —193
109kg (240 lbs.) —193AT
MDF-394*
1,860 x 800 x 945
(73.2 x 31.5 x 37.2)
1,120 x 520 x 530
(44.1 x 20.5 x 20.9)
309 liters (10.9 cu.ft.)
Hermetic type, 450 W
Hermetic type, 750 W
219kg (483 lbs.)
MDF-1156/1156ATN
–125˚C to –152˚C
1,400 x 800 x 945
(55.1 x 31.5 x 37.2)
500 x 450 x 572
(19.7 x 17.7 x 22.5)
128 liters (4.5 cu.ft.)
Aluminum plate
1
Fin and tube type
Cascade condenser
Microprocessor
control system,
Non-volatile memory
265kg (584 lbs.) —1156
272kg (600 lbs.) —1156ATN
MDF-794/794AT
2,570 x 770 x 1,070
(101.2 x 30.3 x 42.1)
1,840 x 500 x 762
(72.4 x 19.7 x 30.0)
701 liters (24.8 cu.ft.)
4
Hermetic type, 1,100 W
Hermetic type, 1,100 W
Shell and tube type
Selectable high temp. alarm (+10˚C & +15˚C from set point)
335kg (739 lbs.) —794
345kg (761 lbs.) —794AT
MDF-594/594AT
2,010 x 770 x 1,070
(79.1 x 30.3 x 42.1)
1,280 x 500 x 762
(50.4 x 19.7 x 30.0)
487 liters (17.1 cu.ft.)
Galvanised steel with baked on finish
Foamed-in-place rigid polyurethane
Fin and tube type
Cascade condenser
Microprocessor: Keypad input
Temp. input range: –20˚C to –95˚C (1˚C increment)
Set value memory: non-volatile memory
Digital display
Power failure alarm, Filter check lamp (Except MDF-193/193AT which have no filters), Remote alarm contact
291kg (642 lbs.) —594
301kg (664 lbs.) —594AT
ATN: LN2 backup system, temperature recorder
AT: LCO2 backup system, temperature recorder
*MDF-394 for 110 to115V and 220V/60Hz is unavailable.
Compressor
Evaporator
Condenser
3
–50˚C to –86˚C
Stainless steel
MDF-59SC (I) version for North America only
*Cooling performance is indicated by the temperature reached at the center of the freezer (at ambient temperature of 30°C with no load).
In order to use the freezer at a stable temperature for a long time, it is recommended that the temperature be set to at least 5°C higher
than the indicated lowest temperature.
In addition, depending on the usage conditions, it may not be possible to reach the indicated lowest temperature.
Cascade condenser
Tube on sheet (shared with interior)
Platinum resistance (Pt. 1000 )
Caution:
SANYO guarantees the product under certain warranty conditions.
SANYO in no way shall be responsible for any loss of content or damage to content.
• Appearance and specifications are subject to change without notice.
Cylinder key on the lid handle and Mouse proof cover on the back side
Adjustable high and low temp. alarm
(±5˚C to ±20˚C from set point)