Installation and Wiring Instructions for the
55- and 12-55- Prefix (Signal Switch) 80 Series
Exit Device to ElectroLynx™ Connector System
For assistance, contact SARGENT at 800-810-WIRE (9473) or www.sargentlock.com

A. Function
The 55- prefix signal switch monitors the touch bar. When the rail is depressed or dogged, the switch is de-activated.

B. Important

1. Caution: Disconnect all input power before beginning installation to prevent electrical shock and
equipment damage.
2. Installer must be a trained, experienced service person.
3. All wiring must comply with applicable local electrical codes, ordinances and regulations.

55- or 12-5580 Series Rail with 8-pin connector

8
7

6 4
5 3

2
1

Blue (C), 55Brown (NO), 55Yellow (NC), 55-

C. ElectroLynx Connector System Notes:
The system is designed to be installation friendly with quick
connectors from the electric hinge through the door to the
rail. The only wiring required is to the loose wires on the
pigtail harness assembly on the frame side of the electric
hinge.

Locking mechanism

Plug
Receptacle

IMPORTANT:
The plug and receptacle connectors are designed to mate
and lock together as shown in the figure. Plug the
connectors into each other with the locking mechanism
aligned as indicated.

Do NOT force connectors on any other way.

Copyright © SARGENT Manufacturing. All rights reserved.
Reproduction in whole or in part without the express written
permission of SARGENT Manufacturing is prohibited.

A6808C

D. Installation Notes
1. With new applications, a raceway harness with 8 and 4 pin connectors will be pre-installed inside door by
ASSA ABLOY door manufacturer when specified during the ordering process. Raceway harness kits are also
available for retrofit applications.
2. If door does not have a raceway harness with connectors, cut connectors off product, or consult factory for
raceway retrofit kit.
3. Wiring to pigtail harness is per facility wiring requirement. The rail, raceway, electric hinge and pigtail connector
terminations and wire colors all match.

E. 55- 80 Series (Signal Switch) Installation and Wiring
55Switch
Connections

mounting
bracket
Electric Hinge
with 8-pin connectors

Yellow (NC), 8

screw
location

1" dia
hole
in door

Brown (NO), 7
Blue (C), 6
8
7

6 4
5 3

Pigtail harness
with 8-pin connector

2
1

1
4
3

NOTES:
1.
2.
3.
4.
5.

Raceway harness with
8 & 4 pin connectors.
The 4-pin connectors
are not used.

Switch contact rating: 2A @ 30VDC
Wires must be protected from abrasion
For use with class II circuits only
Wiring diagram indicates push bar extended
The rail, raceway, electric hinge and pigtail
connector terminations and wire colors all match

2

55- or 12-5580 Series Rail with
8-pin connector

Note: Typical raceway location is
shown. Other locations may exist
depending on door type.

1 Mount exit device per instruction sheet provided
To insure trouble free operation, check that the push rail can be fully depressed. On vertical rod exit
devices, check that the latch bolts do not go into hold back position until the push rail is fully depressed.

2

Plug rail connector into raceway connector. Then feed through 1" hole in door. Install rail mounting bracket with two screws
supplied. Install rail insert and end cap.

3

Plug raceway connector into electric hinge connector, then feed through door prep. Mount electric hinge to door.

4

Go to (A) if wiring now. Go to (B) if wiring is to be done later.
A. Wire frame side wires to wires on pigtail harness as required using connectors allowed by local
code. Plug pigtail harness connector into electric hinge connector. Feed harnesses through frame prep
and mount electric hinge.
B. Plug pigtail harness connector into electric hinge connector. Feed harnesses through frame prep and mount
electric hinge.

Copyright © SARGENT Manufacturing. All rights reserved.
Reproduction in whole or in part without the express written
permission of SARGENT Manufacturing is prohibited.

A6808C



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 2
X Press Private                 : %%DocumentProcessColors: Cyan Magenta Yellow Black.%%EndComments
Creator                         : QuarkXPress(R) 7.31
Modify Date                     : 2008:05:08 15:25:37
Create Date                     : 2008:05:08 15:25:37
Producer                        : QuarkXPress(R) 7.31
Title                           : Layout 1
EXIF Metadata provided by EXIF.tools

Navigation menu