Sargent 1431 Door Closer With UO/O/RO/O8/OLC/P9/RP9/P3/P3A/P4/P4A/Z/OZA Standard Duty Arms (Without Hold Ope A7139K
User Manual: Sargent 1431 Door Closer With UO/O/RO/O8/OLC/P9/RP9/P3/P3A/P4/P4A/Z/OZA Standard Duty Arms (Without Hold Ope Instruction Sheets
Open the PDF directly: View PDF .
Page Count: 8
Download | |
Open PDF In Browser | View PDF |
1431 DOOR CLOSER WITH STANDARD DUTY ARMS (WITHOUT HOLD OPEN) INSTALLATION INSTRUCTIONS 1431 SERIES ADJUSTABLE FROM SIZE 1 THRU 6 FOR INSTALLATION ASSISTANCE, CALL SARGENT AT 1-800-727-5477 • www.sargentlock.com Standard Mounting Application with 0, R0, 08 or 0LC Arm For Standard Applications – Door is mounted on the hinge side of the door (see page 2) Parallel Arm Application with P9, RP9, P3, P3A, P4 or P4A Arm For Parallel Arm Applications – Door Closer is mounted on the top side of the door (see page 4) Top Jamb Application with 0, R0, 0Z or 0ZA Arm For Top Jamb Application – Door Closer is mounted on the frame on the stop side of the door (see page 6) Copyright © 1998, 2000, 2002,2005, 2207-2009, 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited. A7139K - 11/01/11 1 1 2 3 STANDARD APPLICATION • Select closer mounting position based on the maximum door opening, as listed below Note: For ADA applications, select the 160º position. • Using the enclosed self adhesive template, locate and mark hole locations Note: 3/32" pilot holes are required when Self Tapping Screws are being used If machine screws are being used, use a drill #16 (.177) and a #12-24 tap • Install closer body onto the door with 5/8" power adjustment nut end away from hinge • Install foot & rod assembly onto the frames Note: On the foot & rod assembly always use the pivot farthest from the hinge **If butt, frame and wall conditions permit, door will open 180º RIGHT HAND DOOR ILLUSTRATED, SAME DIMENSIONS APPLY FOR LEFT HAND DOOR. *SEE PAGE 8 FOR MORTISE NUTS 4 2 • Install main arm on the closer with the index mark on the spindle aligning with #2 on the main arm (as shown) 11/01/11 A7139K Copyright © 1998, 2000, 2002,2005, 2207-2009, 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited. 5 STANDARD APPLICATION • Opening the door slightly, slide rod into swivel arms and then close the door • With the door closed, position the swivel arm so it is 90º to the door surface • Tighten the arm screw securely 6 Adjust closer as required (See page 8 for details) ACCESSORY INFORMATION Mortise Foot 08 Mortise foot may be used when the standard surface applied foot cannot be attached to the top casing or where appearance is a major factor 1431-J Cover Plate May be used when closer is mounted on a narrow rail to improve appearance when closer is viewed through glass 1431-W Corner bracket May be used for exterior doors to keep the closer inside of building; also to obtain full 180º door opening closer is mounted on bracket attached to door jamb on stop side of door Mortise nuts for bolting through the door are furnished when ordered Copyright © 1998, 2000, 2002,2005, 2207-2009, 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited. A7139K - 11/01/11 3 1 2 3 PARALLEL APPLICATION • Select closer mounting position based on the maximum door opening, as listed below Note: For ADA applications, select the 180º position. • Using the enclosed self adhesive template, locate and mark hole locations Note: 3/32" pilot holes are required when Self Tapping Screws are being used If machine screws are being used, use a drill #16 (.177) and a #12-24 tap • Install closer body onto the door with 5/8" power adjustment nut end towards hinge • Install foot bracket & rod assembly onto the frames Note: P9 or RP9 arm shown. For P3, P3A, P4,P4A arms, use data sheet enclosed LEFT HAND DOOR SHOWN SAME DIMENSIONS APPLY FOR RIGHT HAND DOOR *SEE PAGE 8 FOR MORTISE NUTS 4 11/01/11 A7139K Copyright © 1998, 2000, 2002,2005, 2207-2009, 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited. INSTRUCTIONS FOR INSTALLING PARALLEL ARM APPLICATION 5 Closer mounted on stop side of door • Install main arm on the closer with index mark on spindle aligned with the number on the arm Note: Left Hand Doors – align index mark with the #4 on the main arm (as shown) Right hand Door – align index mark with the #5 on the main arm (as shown) • This requires the spindle to be rotated • Rotate the spindle on the bottom of the closer to align index mark and the required number on the arm 6 • Opening the door slightly, slide rod into swivel arm and then close the door • With the door in the closed position, swivel arm so that the pivot is 1-21/2" off the door surface (as shown below) • Tighten the arm screw securely “ 7 Adjust closer as required (See page 8 for details) ACCESSORY INFORMATION Copyright © 1998, 2000, 2002,2005, 2207-2009, 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited. A7139K - 11/01/11 5 1 2 3 6 top jamb APPLICATION • Select closer mounting position based Reveal Depth as listed below • Locate and mark hole locations Note: 3/32" pilot holes are required when Self Tapping Screws are being used If machine screws are being used, use a drill #16 (.177) and a #12-24 tap • Install closer body onto the door with 5/8" power adjustment nut end away from hinge • Install foot & rod assembly onto the frames 11/01/11 A7139K Copyright © 1998, 2000, 2002,2005, 2207-2009, 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited. INSTRUCTIONS FOR INSTALLING top jamb 4 Closer mounted on frame above stop side of door • Install main arm on the closer with index mark on spindle aligned with the number on the arm Note: Left Hand Doors – align index mark with the #3 on the main arm (as shown) Right hand Door – align index mark with the #1 on the main arm (as shown) • This requires the spindle to be rotated • Rotate the spindle on the top of the closer to align index mark and the required number on the arm 5 • Opening the door slightly, slide rod into swivel arm and then close the door • With the door closed, position the main arm so it is at 90º to the door surface • Tighten the arm screw securely 6 final adjustment and regulating procedure • Adjust door speed and latching speed valves to achieve the desired closing time. Recommend 6 seconds minimum for 90º to the closed position • If backcheck is required, adjust valve to achieve a slight cushioning effect. Auxiliary stop required. • If closer is equipped with delayed action, regulate valve to achieve the desired delay Adjust closing power to the minimum required to reliably close and latch door • If door is hard to open, decrease power slightly • If door does not latch, increase power as required • Use the chart (on the left) as a starting point • Doors adjusted with high closing power to overcome strong draft conditions may exceed ADA standards Copyright © 1998, 2000, 2002,2005, 2207-2009, 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited. A7139K - 11/01/11 7 Additional Power Adjustment Through Bolts Adjusting foot for additional closing power (for standard and top jamb applications only) 1. For top jamb and corner bracket applications: The door closer foot will be attached to the door in a manner similar to that shown for mounting the closer body 2. For doors 2-1/4" thick: Mortise nut shown for 1-3/4" thick doors will be furnished along with appropriate length through-bolts, door construction must provide a bridge type reinforcement to prevent the door rail form collapsing with through-bolts are tightened. INSTALL COVER AS FOLLOWS: For top jamb application For standard an parallel arm application • Assemble plastic support and long cover screw (#8-32 1-1/4") into top of case approximately 2 turns • Screw short cover screw (#8-32 x 5/16") into top of case approximately 2 turns • Assemble plastic support and long cover screw (#8-32 x 1-1/4") into bottom of case approximately 2 turns • Hold support against case and slide cover into gap between flange and screw head • Position cover on closer and tighten screws 8 11/01/11 A7139K Copyright © 1998, 2000, 2002,2005, 2207-2009, 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited. • Screw short cover screw (#8-32 x 5/16") into bottom of case approximately 2 turns • Slide cover into gap between flange and screw head. Position cover on closer and tighten screws
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Create Date : 2011:12:08 09:10:27-05:00 Creator : Adobe InDesign CS5 (7.0.4) Modify Date : 2011:12:08 09:15:09-05:00 XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:56:37 Metadata Date : 2011:12:08 09:15:09-05:00 Creator Tool : Adobe InDesign CS5 (7.0.4) Instance ID : uuid:22433366-a322-1241-bafd-931987979f3d Document ID : xmp.did:B4834774072068118A6D971B89448264 Original Document ID : xmp.did:B4834774072068118A6D971B89448264 Rendition Class : proof:pdf History Action : created, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved History Instance ID : xmp.iid:B4834774072068118A6D971B89448264, xmp.iid:C0B413D72F2068118A6D971B89448264, xmp.iid:C1B413D72F2068118A6D971B89448264, xmp.iid:CAB413D72F2068118A6D971B89448264, xmp.iid:CEB061B3152068118A6DFA814A0BD44C, xmp.iid:E20C1874072068118C14A0C72FBEBAB2, xmp.iid:86EF86E9092068118C14A0C72FBEBAB2, xmp.iid:DC9FCF110A2068118C14A0C72FBEBAB2, xmp.iid:F433980C0D2068118C14A0C72FBEBAB2, xmp.iid:F113CD180D2068118C14A0C72FBEBAB2, xmp.iid:1EF180F0262068118C14A0C72FBEBAB2, xmp.iid:A42705EB282068118C14A0C72FBEBAB2, xmp.iid:6726A341292068118C14A0C72FBEBAB2, xmp.iid:EC1F33E6302068118C14A0C72FBEBAB2, xmp.iid:F22E8813322068118C14A0C72FBEBAB2, xmp.iid:51D492A2342068118C14A0C72FBEBAB2, xmp.iid:C073C7B3352068118C14A0C72FBEBAB2, xmp.iid:333F6490362068118C14A0C72FBEBAB2, xmp.iid:8A4DB479372068118C14A0C72FBEBAB2, xmp.iid:74447855392068118C14A0C72FBEBAB2, xmp.iid:02E40874392068118C14A0C72FBEBAB2, xmp.iid:A39BF14B3C2068118C14A0C72FBEBAB2, xmp.iid:3EFDB264162068118A6DE1454F0D4FC6, xmp.iid:401CCAAD162068118A6DE1454F0D4FC6, xmp.iid:A55777A30D2068118A6DE01D6CC3F41C, xmp.iid:1CA0048B0E2068118A6DE01D6CC3F41C, xmp.iid:6A2ABE150F2068118A6DE01D6CC3F41C, xmp.iid:6B2ABE150F2068118A6DE01D6CC3F41C, xmp.iid:4B63B6F9132068118A6D8E7179B2E2B1, xmp.iid:03573F32142068118A6D8E7179B2E2B1, xmp.iid:2B6FD172102068118C14F12624B7D47F History When : 2011:11:01 13:49:51-04:00, 2011:11:01 13:59:55-04:00, 2011:11:01 13:59:55-04:00, 2011:11:01 14:54:15-04:00, 2011:11:04 10:52:51-04:00, 2011:11:09 09:15:41-05:00, 2011:11:09 09:33:17-05:00, 2011:11:09 09:34:25-05:00, 2011:11:09 09:55:45-05:00, 2011:11:09 09:56:05-05:00, 2011:11:09 13:50:49-05:00, 2011:11:09 14:04:59-05:00, 2011:11:09 14:07:25-05:00, 2011:11:09 15:02:07-05:00, 2011:11:09 15:10:33-05:00, 2011:11:09 15:28:53-05:00, 2011:11:09 15:36:31-05:00, 2011:11:09 15:42:41-05:00, 2011:11:09 15:49:13-05:00, 2011:11:09 16:02:31-05:00, 2011:11:09 16:03:22-05:00, 2011:11:09 16:23:44-05:00, 2011:11:10 09:48:17-05:00, 2011:11:10 09:50:20-05:00, 2011:11:16 09:18:12-05:00, 2011:11:16 09:24:40-05:00, 2011:11:16 09:28:33-05:00, 2011:11:16 09:30:05-05:00, 2011:12:02 09:37:08-05:00, 2011:12:02 09:38:43-05:00, 2011:12:08 09:09:48-05:00 History Software Agent : Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0 History Changed : /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata Doc Change Count : 5843 Format : application/pdf Producer : Adobe PDF Library 9.9 Trapped : False Page Count : 8EXIF Metadata provided by EXIF.tools