Sargent 1431 Door Closer With UO/O/RO/O8/OLC/P9/RP9/P3/P3A/P4/P4A/Z/OZA Standard Duty Arms (Without Hold Ope A7139K

User Manual: Sargent 1431 Door Closer With UO/O/RO/O8/OLC/P9/RP9/P3/P3A/P4/P4A/Z/OZA Standard Duty Arms (Without Hold Ope Instruction Sheets

Open the PDF directly: View PDF PDF.
Page Count: 8

1
A7139K - 11/01/11
Copyright © 1998, 2000, 2002,2005, 2207-2009, 2011, Sargent Manufacturing Company,
an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part
without the express written permission of Sargent Manufacturing Company is prohibited.
1431 DOOR CLOSER WITH STANDARD DUTY ARMS
(WITHOUT HOLD OPEN) INSTALLATION INSTRUCTIONS
1431 SERIES ADJUSTABLE FROM SIZE 1 THRU 6
FOR INSTALLATION ASSISTANCE, CALL SARGENT AT 1-800-727-5477 • www.sargentlock.com
Standard Mounting Application with
0, R0, 08 or 0LC Arm
For Standard Applications – Door is mounted on the hinge side
of the door (see page 2)
Parallel Arm Application with
P9, RP9, P3, P3A, P4 or P4A Arm
For Parallel Arm Applications – Door Closer is mounted on the
top side of the door (see page 4)
Top Jamb Application with
0, R0, 0Z or 0ZA Arm
For Top Jamb Application – Door Closer is mounted on the
frame on the stop side of the door (see page 6)
2Copyright © 1998, 2000, 2002,2005, 2207-2009, 2011, Sargent Manufacturing Company,
an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part
without the express written permission of Sargent Manufacturing Company is prohibited.
11/01/11
A7139K
Select closer mounting position based on the maximum door opening, as listed below
Note: For ADA applications, select the 160º position.
1
STANDARD APPLICATION
Using the enclosed self adhesive template, locate and mark hole locations
Note: 3/32" pilot holes are required when Self Tapping Screws are being used
If machine screws are being used, use a drill #16 (.177) and a #12-24 tap
2
Install closer body onto the door with 5/8" power adjustment nut end away from hinge
Install foot & rod assembly onto the frames
3
** If butt, frame and wall conditions permit,
door will open 180º
Note: On the foot & rod assembly always
use the pivot farthest from the hinge
RIGHT HAND DOOR ILLUSTRATED, SAME DIMENSIONS APPLY FOR LEFT HAND DOOR.
*SEE PAGE 8 FOR MORTISE NUTS
Install main arm on the closer with the index mark on the spindle aligning with #2 on the main arm (as shown)
4
STANDARD APPLICATION
Opening the door slightly, slide rod into swivel arms and then close the door
With the door closed, position the swivel arm so it is 90º to the door surface
Tighten the arm screw securely
5
Adjust closer as required (See page 8 for details)
6
ACCESSORY INFORMATION
08 Mortise foot may be
used when the standard
surface applied foot
cannot be attached to
the top casing or where
appearance is a major
factor
Mortise Foot
1431-J Cover Plate
May be used when closer is mounted on a narrow
rail to improve appearance when closer is viewed
through glass
1431-W Corner bracket
May be used for exterior doors to keep the closer inside of building;
also to obtain full 180º door opening closer is mounted on bracket
attached to door jamb on stop side of door
Mortise nuts for bolting through the door are furnished when ordered
3
A7139K - 11/01/11
Copyright © 1998, 2000, 2002,2005, 2207-2009, 2011, Sargent Manufacturing Company,
an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part
without the express written permission of Sargent Manufacturing Company is prohibited.
4Copyright © 1998, 2000, 2002,2005, 2207-2009, 2011, Sargent Manufacturing Company,
an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part
without the express written permission of Sargent Manufacturing Company is prohibited.
11/01/11
A7139K
Select closer mounting position based on the maximum door opening, as listed below
Note: For ADA applications, select the 180º position.
1
PARALLEL APPLICATION
Using the enclosed self adhesive template, locate and mark hole locations
Note: 3/32" pilot holes are required when Self Tapping Screws are being used
If machine screws are being used, use a drill #16 (.177) and a #12-24 tap
2
Install closer body onto the door with 5/8" power adjustment nut end towards hinge
Install foot bracket & rod assembly onto the frames
3
Note: P9 or RP9 arm shown.
For P3, P3A, P4,P4A arms,
use data sheet enclosed
LEFT HAND DOOR SHOWN
SAME DIMENSIONS APPLY FOR RIGHT HAND DOOR *SEE PAGE 8 FOR MORTISE NUTS
INSTRUCTIONS FOR INSTALLING PARALLEL ARM APPLICATION
Closer mounted on stop side of door
Install main arm on the closer with index mark on spindle aligned with the number on the arm
Note: Left Hand Doors – align index mark with the #4 on the main arm (as shown)
Right hand Door – align index mark with the #5 on the main arm (as shown)
This requires the spindle to be rotated
Rotate the spindle on the bottom of the closer to align index mark and the required number on the arm
5
• Opening the door slightly, slide rod into swivel arm and then close the door
With the door in the closed position, swivel arm so that the pivot is 1-21/2" off the door surface (as shown below)
Tighten the arm screw securely
6
Adjust closer as required (See page 8 for details)
7
ACCESSORY INFORMATION
5
A7139K - 11/01/11
Copyright © 1998, 2000, 2002,2005, 2207-2009, 2011, Sargent Manufacturing Company,
an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part
without the express written permission of Sargent Manufacturing Company is prohibited.
6Copyright © 1998, 2000, 2002,2005, 2207-2009, 2011, Sargent Manufacturing Company,
an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part
without the express written permission of Sargent Manufacturing Company is prohibited.
11/01/11
A7139K
Select closer mounting position based Reveal Depth as listed below
1
TOP JAMB APPLICATION
Locate and mark hole locations
Note: 3/32" pilot holes are required when Self Tapping Screws are being used
If machine screws are being used, use a drill #16 (.177) and a #12-24 tap
2
Install closer body onto the door with 5/8" power adjustment nut end away from hinge
Install foot & rod assembly onto the frames
3
INSTRUCTIONS FOR INSTALLING TOP JAMB
Closer mounted on frame above stop side of door
Install main arm on the closer with index mark on spindle aligned with the number on the arm
Note: Left Hand Doors – align index mark with the #3 on the main arm (as shown)
Right hand Door – align index mark with the #1 on the main arm (as shown)
This requires the spindle to be rotated
Rotate the spindle on the top of the closer to align index mark and the required number on the arm
4
Opening the door slightly, slide rod into swivel arm and then
close the door
With the door closed, position the main arm so it is at 90º to
the door surface
Tighten the arm screw securely
5
Adjust door speed and latching speed valves to achieve the desired closing time. Recommend 6 seconds minimum
for 90º to the closed position
If backcheck is required, adjust valve to achieve a slight cushioning effect. Auxiliary stop required.
If closer is equipped with delayed action, regulate valve to achieve the desired delay
6
7
A7139K - 11/01/11
Copyright © 1998, 2000, 2002,2005, 2207-2009, 2011, Sargent Manufacturing Company,
an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part
without the express written permission of Sargent Manufacturing Company is prohibited.
FINAL ADJUSTMENT AND REGULATING PROCEDURE
Adjust closing power to the minimum required
to reliably close and latch door
• If door is hard to open, decrease power slightly
• If door does not latch, increase power as required
• Use the chart (on the left) as a starting point
Doors adjusted with high closing power to
overcome strong draft conditions may exceed
ADA standards
8Copyright © 1998, 2000, 2002,2005, 2207-2009, 2011, Sargent Manufacturing Company,
an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part
without the express written permission of Sargent Manufacturing Company is prohibited.
11/01/11
A7139K
Additional Power Adjustment
Adjusting foot for additional closing
power (for standard and top jamb
applications only)
1. For top jamb and corner bracket
applications: The door closer foot will
be attached to the door in a manner
similar to that shown for mounting the
closer body
2. For doors 2-1/4" thick: Mortise nut
shown for 1-3/4" thick doors will be
furnished along with appropriate length
through-bolts, door construction must
provide a bridge type reinforcement to
prevent the door rail form collapsing
with through-bolts are tightened.
INSTALL COVER AS FOLLOWS:
For standard an parallel arm application
Screw short cover screw (#8-32 x 5/16") into top of case
approximately 2 turns
Assemble plastic support and long cover screw (#8-32 x 1-1/4")
into bottom of case approximately 2 turns
Hold support against case and slide cover into gap between
flange and screw head
• Position cover on closer and tighten screws
For top jamb application
Assemble plastic support and long cover screw (#8-32 1-1/4")
into top of case approximately 2 turns
Screw short cover screw (#8-32 x 5/16") into bottom of case
approximately 2 turns
Slide cover into gap between flange and screw head. Position
cover on closer and tighten screws
Through Bolts

Navigation menu