Sargent KP8200 Keypad Mortise Lock Programming Instructions A7373
User Manual: Sargent KP8200 Keypad Mortise Lock Programming Instructions Instruction Sheets
Open the PDF directly: View PDF .
Page Count: 23
Download | |
Open PDF In Browser | View PDF |
KP KP Series Keypad Mortise Lock Installation & Programming Instructions A7373C 03/14 Copyright 2014, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited. Table of Contents 1 1 Warning ....................................................................................3 2 General Description..................................................................4 3 Specifications...........................................................................4 4 Features....................................................................................5 5 Parts Breakdown......................................................................6 6 Installation Instructions...........................................................8 7 Operational Check..................................................................18 8 Programming Instructions ....................................................18 Warning Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna • Increase the separation between the equipment and receiver • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected • Consult the dealer or an experienced TV technician for help This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme avec la norme NMB-003 du Canada. 03/31/14 Any retrofit or other field modification to a fire rated opening can potentially impact the fire rating of the opening, and SARGENT makes no representations or warranties concerning what such impact may be in any specific situation. When retrofitting any portion of an existing fire rated opening, or specifying and installing a new fire-rated opening, please consult with a code specialist or local code official (Authority Having Jurisdiction) to ensure compliance with all applicable codes and ratings ! To comply with “Fire Listed” doors, the batteries must be replaced with alkaline batteries only. Do not install batteries if controller is powered by external power supply. ! Warning SARGENT Mfg. Co. locksets utilizing a door position switch (DPS) are not rated for, or intended for use in life safety applications. 1-800-810-WIRE • www.sargentlock.com • A7373C Copyright © 2014, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. KP Series Keypad Mortise Lock 2 General Description The SARGENT KP Series Mortise Lock is designed for areas which require stand alone authorized entry. It is a self-contained microprocessor-controlled keypad with non-volatile memory. The keypad holds a total of 100 different user codes. User codes 01, 02 and 03 are utilized for Master Code, Emergency Code and Supervisory Code, respectively. This motorized 8200 mortise lock is operated by four (4) “C” alkaline batteries. SARGENT mortise locks are designed with quality components to provide high security, performance and durability. 3 03/31/14 Copyright © 2014, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. 4 Specifications • Latchbolt - Stainless Steel • Deadbolt - Stainless Steel • Guardbolt - Stainless Steel, non handed • Handed - Easily field reversible without disassembling the lock body • Case - 12 gauge heavy duty wrought steel • Outside lever controlled by keypad • Inside lever retracts latchbolt and deadbolt • Locks furnished for 1 3/4” doors. Can be furnished for other door sizes upon request. (Consult factory) • UL Listed (3 hr.) • Accepts size 41(standard) and 42 (removable core) SARGENT mortise cylinders (KP8276 and KP8278) • Key retracts latchbolt (KP8276 and KP8278) • Operates utilizing any two to six digits per code. Digits may be repeated and codes may start with zero • Adjustable unlock time • Entry of three wrong User Codes disables all codes for ten seconds. Green LED flashes. • Piezo horn can be heard with each keystroke or turned off by Master or Supervisory Code • Last 15 transactions can be output to printer via Data Transfer Device (DTD) • 100 users total: one Master Code, one Emergency Code, one Supervisory Code, with the rest being standard codes, passage codes, or one time only codes Features • Non-volatile memory • Motor driven, battery operated mortise lock • Battery operated with 4 (each) “C” Alkaline • Low battery alert – 4 chirps after code entry • Option Code available to sound horn every time keypad is pressed • External remote “request to enter” connector requires wire harness (52-2071) • External battery input connector included to power unit in event of battery failure • All programming done at keypad • Deadbolt switch inside mortise lock allows Emergency Code and Master Code users to gain entry when deadbolt is thrown* * PHR-prefix locks will not allow Emergency or Master Code users entry when deadbolt is thrown. Entry is through key cylinder override only. 4 1-800-810-WIRE • www.sargentlock.com • A7373C KP Series Keypad Mortise Lock Features (continued) 4 KP8276 • • KP8278 Deadbolt function Cylinder override provided • • KP8277 • • Deadbolt function No cylinder override KP8279 Cylinder override provided No deadbolt function • • No cylinder override No deadbolt function Keypad Tactile keypad made of Ultraviolet stable material LED’s indicate valid or invalid entries Green LED indicates unlocked.Yellow LED indicates unit is in programming mode Flashing green and yellow LED’s indicate deadbolt thrown or lock set in passage mode Infrared LED for transaction output. Provides last 15 valid codes. • • • • • • • Outside Escutcheon with Keypad Outside Lever Handle Assembly Inside Lever Handle Mortise cylinder Inside Escutcheon with Circuit Board and Battery Pack Batteries (4 “C”) Tool (security socket screw key 1/8”) Items included in your KP8277/KP8279 Keypad Mortise Lock: • • • • • • Outside Escutcheon with Keypad Outside Lever Handle Assembly Inside Lever Handle Inside Escutcheon with Circuit Board and Battery Pack Batteries (4 “C”) Tool (security socket screw key 1/8”) 1-800-810-WIRE • www.sargentlock.com • A7373C Copyright © 2014, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Items included in your KP8276/KP8278 Keypad Mortise Lock: 5 03/31/14 • • • • • 03/31/14 Copyright © 2014, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. KP Series Keypad Mortise Lock 5 6 Parts Breakdown KP Series Parts List 3 2 14 16 25 1 8 4 6 10 7 Inside of Door 1-800-810-WIRE • www.sargentlock.com • A7373C 5 15 22 23 12 17 13 19 18 KP8276 ONLY KP8278 20 9 11 21 Outside of Door KP Series Keypad Mortise Lock Parts Breakdown (Continued) Req. Description 1 01-0803 Battery Alkaline (“C” cell) 4 2 3 4 5 6 01-1119 01-0297 01-1157 01-0440 81-0467 81-0468 81-0490 81-0470 81-0471 81-4648 81-0447 81-0489 81-0513 81-0445 01-1472 01-1174 #8-32 x 1-1/2 Flat Head Screw Security Socket Screw Key (1/8) #8-32 x 1-1/4 Phillips Pan Head Screw Flat Washer Inside Lever (L.H.) A” Design Inside Lever (R.H.) A” Design Inside Lever B” Design Inside Lever E” Design Inside Lever F” Design Inside Lever H” Design Inside Lever J” Design Inside Lever L” Design Inside Lever P” Design Inside Lever W” Design Lever Handle Screw A, E, F & H (Lever) Lever Handle Screw B, J, L, P & W (Lever) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 8 9 10 11 12 13 14 15 16 17 82-0347 82-0368 81-0093 01-4388 01-1495 82-3088 52-0033 01-1500 52-2340 77-0566 Handle Spring Spindle LN” Rose #8 x 1 Phillips Flat Head Screw #8-32 x 5/8 Machine Screw Inside Lever Adapter & Plate Assembly Fire Stop Plate #8 x 1/2 Pan Head Self Tapping Screw Outside Escutcheon & Keypad Assembly Cylinder Rosette (Size 41 Cylinder) 1 1 1 1 2 1 1 2 1 1 18 13-0596 13-0489 13-0490 Cylinder Rosette (Size 42 Cylinder) Cylinder Ring (Size 41 Cylinder) Cylinder Ring (Size 42 Cylinder) 1 1 1 19 20 13-0140 OS-8276 x LNA Compression Spring Outside Lever (R.H.) A” Design (L.H.) A” Design “ 1 1 1 OS-8276 x LNB OS-8276 x LNE OS-8276 x LNF OS-8276 x LNH OS-8276 x LNJ OS-8276 x LNL OS-8276 x LNP OS-8276 x LNW OS-8276 x LA Outside Lever B” Design “ Outside Lever E” Design “ Outside Lever F” Design “ Outside Lever H” Design Outside Lever J” Design Outside Lever L” Design Outside Lever P” Design Outside Lever W” Design “ Outside Lever (R.H.) A” Design “ (L.H.) A” Design “ Outside Lever B” Design “ Outside Lever E” Design “ Outside Lever F” Design “ Outside Lever H” Design “ Outside Lever J” Design “ Outside Lever L” Design Outside Lever P” Design “ Outside Lever W” Design Outside Front #8-32x1/4 FL HD Screw Lockbody Screws for Wood #12x1-1/4 FL HD (not shown) Lockbody Screws for Metal #12-24x1/2 FL HD (not shown) Outside Front (KP8276 & KP8277) Outside Front (KP8278 & KP8279) 1 1 1 1 1 1 1 1 1 7 21 22 23 24 25 26 OS-8276 x LB OS-8276 x LE OS-8276 x LF OS-8276 x LH OS-8276 x LJ OS-8276 x LL OS-8276 x LP OS-8276 x LW 01-1028 01-2299 01-1019 82-0084 82-0081 KP-8276-hand-finish Lockbody Assembly with deadbolt & cylinder KP-8277-hand-finish Lockbody Assembly with deadbolt only (no cylinder) KP-8278-hand-finish KP-8279-hand-finish 82-3730 82-3729 Lockbody Assembly with cylinder only (no deadbolt) Lockbody Assembly without deadbolt & without cylinder Inside Escutcheon Assembly (Turn Lever-KP8276/KP8777) Inside Escutcheon Assembly (Hole Plug-KP8278/KP8779) 52-4758 Inside Escutcheon Assembly (Turn Lever-KP8276 only*) Copyright © 2014, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Part # 1 1 1 1 1 1 1 1 2 2 2 1 1 1 1 1 1 * PHR-prefix locks will not allow Emergency or Master Code users entry when deadbolt is thrown. Entry is through key cylinder override only. 1-800-810-WIRE • www.sargentlock.com • A7373C 7 03/31/14 Item KP Series Keypad Mortise Lock 6 Installation Instructions Step #1 – Verify Hand and Bevel of Door A. Verify Hand and Bevel of Door Stand on outside/locked side of door when determining the door hand LH LHRB Left Hand Hinges Left Open Inward RH Left Hand Reverse Bevel Hinges Left Open Outward Right Hand Hinges Right Open Inward RHRB Right Hand Reverse Bevel Hinges Right Open Outward Fig. 1A B. Prepare Door Prep door according to Instruction Sheet A7454 and appropriate template: Manufacturer Door Template: 4632 03/31/14 Copyright © 2014, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Documents are available at www.sargentlock.com Inside of Door Outside of Door Through-bolt Hole Ribbon Cable Hole (Controller to Keypad) Outside Cylinder Hole (76 and 78 Functions) Inside Cylinder Hole Thumb Turn Lever Hole Lever Handle Hole Mortised Pocket Lever Handle Hole Through-bolt Hole Pre-drilled and/or Tapped Holes (2 places) Fig. 1B Wood Door Preparation 8 1-800-810-WIRE • www.sargentlock.com • A7373C KP Series Keypad Mortise Lock Step #2 – Verify Hand and Bevel of Door A. Reverse Lock Hand Red surface of locking piece must face the outside/locked side of door. To rotate locking piece (Fig. 2A): 1. Position lock body with red surface of locking piece visible. 2. Insert blade type screwdriver into locking piece slot to rotate locking piece toward back of lock body. 3. Rotate the locking piece 180° until RED surface is on opposite side. Note: Red indicates locked side (outside). Right Hand Lock Shown Locking Slide Red on Locked Side Push In B. Reverse Latch Hand Beveled surface of latchbolt must face strike (Fig. 2B). The deadlatch is self adjusting. To change the hand of the latchbolt: 1. Insert the blade of a slotted screwdriver (>1/4”) into the spade shape slot behind latch. 2. Rotate the screwdriver 90° to push latchbolt out until back of bolt clears lock case front. Spade Shaped Slot Latchbolt 3. Rotate latchbolt 180° until the latchbolt drops back into the lock body. Deadlatch Note: Latch cannot be unscrewed. Fig. 2B 1-800-810-WIRE • www.sargentlock.com • A7373C 9 03/31/14 Copyright © 2014, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Fig. 2A KP Series Keypad Mortise Lock Step #3 – Install Lock Body Inside of Door 1. Insert lock body into mortised cutout (Fig. 3A). 03/31/14 Copyright © 2014, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Fig. 3A 2. Hold lock body loosely in place with (2) lock body screws. Note: Do not completely tighten screws at this time. Outside of Door Harness exits Non-Cylinder side (2) #12-24 x 1/2” Flat Head Screws (Metal Doors) (2) #12 x 1-1/4” Flat Head Screws (Metal Doors) Fig. 3B 10 1-800-810-WIRE • www.sargentlock.com • A7373C KP Series Keypad Mortise Lock Step #4 – Exterior Door Options A. Fire Stop Plate (P/N 53-0033) Fire-rated doors require a fire stop plate on the outside of the door (Fig. 4A). 1. Drill (2) 1/8” x 1-1/4” deep holes in the door if not already present. Ribbon Cable Hole Refer to template for fire-stop prep locations. 2. Attach with flap up and out using (2) #8 x 1/2” self-tapping screws for wood and metal doors. Slot 7/8” Fig.4B Fire Stop Plate of 1-1/2” Diameter 1-1/2” Install weather conduit on NON FIRE-RATED exterior doors only. (2) Self Tapping Screws #8 x 1/2” for Wood and Metal Doors 1. Carefully insert the weather conduit into the ribbon cable hole on the inside of the door (Fig. 4B). O-Ring Outside of Door 2. Place the O-ring around the weather conduit on the outside and up against the door (Fig. 4C). Fig.4C Step #5 – Install Weatherseal Gasket (Exterior Doors) Copyright © 2014, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Fig. 4A Peel back 1. Carefully remove adhesive backing from the gasket (Fig. 5A). 2. Apply gasket to escutcheon: • Starting in one place, press the adhesive side of the gasket firmly against the escutcheon. • Work around the escutcheon, pressing the sticky side of the gasket firmly against the escutcheon edge. Fig. 5A • The gasket should be aligned so that all edges of the escutcheon are covered. 3. Attach escutcheon to the door. Note: The 43 cylinder may be used with or without a gasket. Fig. 5B 1-800-810-WIRE • www.sargentlock.com • A7373C 11 03/31/14 B. Weather Conduit (P/N 52-2847) (2) 1/8” Diameter Holes Required 03/31/14 Copyright © 2014, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. KP Series Keypad Mortise Lock Step #6 – Install Outside Escutcheon and Lever Assembly Install Outside Lever Assembly 12 1-800-810-WIRE • www.sargentlock.com • A7373C 1-800-810-WIRE • www.sargentlock.com • A7373C 13 03/31/14 Copyright © 2014, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. KP Series Keypad Mortise Lock Step #7 – Install Inside Escutcheon Inside Escutcheon Assembly 03/31/14 Copyright © 2014, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. KP Series Keypad Mortise Lock Step #8 – Inside Lever Installation 14 1-800-810-WIRE • www.sargentlock.com • A7373C 1-800-810-WIRE • www.sargentlock.com • A7373C 15 03/31/14 Copyright © 2014, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. KP Series Keypad Mortise Lock Step #8 – Continued 03/31/14 Copyright © 2014, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. KP Series Keypad Mortise Lock Step #9 – KP8276 and KP8278 Only - Install Cylinder Position cylinder so that the SARGENT logo is right-side up. Correct 16 1-800-810-WIRE • www.sargentlock.com • A7373C Incorrect Copyright © 2014, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Step #11 – Battery Installation 1-800-810-WIRE • www.sargentlock.com • A7373C 17 03/31/14 KP Series Keypad Mortise Lock Step #10 – Application of Front Plate KP Series Keypad Mortise Lock 7 Operational Check • • • • • Place key into cylinder and rotate key. The key will retract the latchbolt. If the deadbolt is thrown, the key will retract both the deadbolt and the latchbolt. Inside handle lever retracts latchbolt and (if provided). Enter 1234* to unlock outside lever handle and retract latchbolt and deadbolt (if provided). N Q P O S R T G U V M @ Deadbolt (KP8276/KP8278) 03/31/14 Copyright © 2014, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Latchbolt Inside of Door Outside of Door • Key should rotate freely. There should be no friction against lock case, wire harness or any other obstructions. • Refer to Step 7 if harness friction exists. • Rotate cylinder further into lock case to eliminate lockbody obstruction. 8 Programming Instructions The KP Keypad Lock can support 100 users. Each user is assigned a User Number in addition to the code used for entry. Example: 18 USER TYPE USER NUMBER USER CODE (2-6 DIGITS) Master 01 1234 Emergency 02 22222 Supervisor 03 303030 Standard 04-97 Special Factory 10 Sec. Time Preset 98 99 1-800-810-WIRE • www.sargentlock.com • A7373C 265 1368 KP Series Keypad Mortise Lock This Keypad Mortise Lock has 99 User Codes available for programming purposes. • The Master Code is always User “01”. The Master Code assigns the Emergency and Supervisory Codes. It is also used for programming and will override the deadbolt*. Users are deleted through the Master Programming Code only. • The Emergency Code is always User “02”. The Emergency Code will override the deadbolt* in the mortise lock and has an unlock time of 10 seconds. • The Supervisory Code is always User “03”. The Supervisory Code allows temporary lockout of selected users, changes duration of unlock time, requests infrared interrogation output, and may add additional User Codes. • The first User Code will be User “04” or higher. User numbers do not have to be used or entered sequentially. • User codes “98” and “99” have a factory-set unlock time of ten seconds. This allows a handicapped person extra time which would not be required by other users. *NOTE: PHR-prefix locks will not allow Emergency or Master Code users entry when deadbolt is thrown. Entry (with deadbolt thrown) is through key cylinder override only. To Begin Programming: The Keypad Mortise Lock is preset at the factory with Master Code “1234”. Entering “1234*” will unlock the lock allowing the lever handle to retract the latchbolt. Initial Set-Up Procedures: • The following are typical procedures to follow when setting up your KP Series Keypad. • If a mistake is made during any of procedures, depress the “*” several times until the yellow LED goes out. • If no keystroke is made in a 30-sec time frame the programming up to that point will default and you will have to start over. All of the following procedures start with 99#. Change Master Code: • 1234* (Yellow LED Begins to Blink Slowly) This example uses the Factory Default Master Code • 50# 1# 01# New Master Code* (Yellow LED Blinks Quickly) • New Master Code* (Yellow LED Blinks Slowly) * (Yellow LED Goes Out) To Enter the Emergency Code: (Unlock Duration is Factory Set at 10 Sec) • Master Code* (Yellow LED Begins to Blink Slowly) • 50# 1# 02# Emergency Code* (Yellow LED Blinks Quickly) • Emergency Code* (Yellow LED Blinks Slowly) * (Yellow LED Goes Out) To Enter the Supervisory Code: • Master Code* (Yellow LED Begins to Blink Slowly) • 50# 1# 03# Supervisory Code* (Yellow LED Blinks Quickly) • Supervisory Code* (Yellow LED Blinks Slowly) * (Yellow LED Goes Out) To Enter a User Code: • Supervisory or Master Code* (Yellow LED Begins to Blink Slowly) • 50# 1# User Number (04-97)# User Code* (Yellow LED Blinks Quickly) • User Code* (Yellow LED Blinks Slowly) * (Yellow LED Goes Out) 1-800-810-WIRE • www.sargentlock.com • A7373C 19 03/31/14 Copyright © 2014, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. If after the last “ *” is depressed, the yellow LED does not go out, depress “ *” once more. KP Series Keypad Mortise Lock All of the following procedures start with 99# (continued). If after the last “*” is depressed, the yellow LED does not go out, depress “*” once more. To Enter a Passage (Maintained Mode) Code: When Passage Mode is used, the same User Code must be used to re-lock the lock. • Supervisory or Master Code* (Yellow LED Begins to Blink Slowly) • 50# 2# User Number (04-97)# User Code* (Yellow LED Blinks Quickly) • User Code* (Yellow LED Blinks Slowly) * (Yellow LED Goes Out) To Enter a One Time User Code: • Supervisory or Master Code* (Yellow LED Begins to Blink Slowly) • 50# 3# User Number# User Code* (Yellow LED Blinks Quickly) • User Code* (Yellow LED Blinks Slowly) * (Yellow LED Goes Out) To Deactivate “Beep” With the Depression of Each Key: • Supervisory or Master Code* (Yellow LED Begins to Blink Slowly) • 30# 0# 0# (Yellow LED Continues to Blink Slowly) • * (Yellow LED Blinks Quickly) • * (No Beep on Depression and Yellow LED Blinks Slowly) • * (No Beep on Depression and Yellow LED Goes Out) To Reactivate “Beep” With the Depression of Each Key: Copyright © 2014, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. • Supervisory or Master Code* (Yellow LED Begins to Blink Slowly) • 30# 0# 1# (Yellow LED Continues to Blink Slowly) • * (Yellow LED Blinks Quickly) • * (Beep on Depression and Yellow LED Blinks Slowly) • * (Beep on Depression and Yellow LED Goes Out) To Clear the Entire Memory: • Master Code* (Yellow LED Begins to Blink Slowly) • 46# 00000# 00000# (Yellow LED Continues to Blink Slowly) • * (Yellow LED Blinks Quickly) • * (No Beep on Depression and Yellow LED Goes Out) • PAUSE, Yellow LED Begins to Blink Again • * (Yellow LED Goes Out) NOTE This Deletes ALL Codes, including Master, Emergency and Supervisory. The Master Code is set back to 1234, Door Number to 0001 and Unlock time to 5 Sec. If the Master Code is not known, Factory Assistance will be required to clear the memory. 1-800-810-WIRE. To Program Door Numbers into Keypad: • Master Code* (Yellow LED Begins to Blink Slowly) • 43# 0# Door Number# (must be four digits) (Yellow LED Blinks Slowly) • * (Yellow LED Begins to Blink Quickly) • * (Yellow LED Blink Slowly) 03/31/14 • * (Yellow LED Goes Out) 20 1-800-810-WIRE • www.sargentlock.com • A7373C KP Series Keypad Mortise Lock All of the following procedures start with 99# (continued). If after the last “*” is depressed, the yellow LED does not go out, depress “*” once more. To Interrogate Transaction Log: • Supervisory or Master Code* (Yellow LED Begins to Blink Slowly) • 70# 0# 0# (Yellow LED Blinks Slowly) Seq User Trans 1 001 003 Hold an infrared printer up to the red infrared LED (as shown). A Data Transfer Device (DTD) can be used to download information from the keypad to a printout. 2 003 001 Illustration 3 003 001 4 020 001 5 003 001 Door # 5666 • * (Yellow LED Begins to Blink Quickly) • * (Yellow LED Goes Out) Door Number For additional information, see “Transaction Log”. Note: Seq. # 1 is the programming request to output the entries. Sequence numbers 2-6 are the actual entries. Transaction Number User Number Transaction Type To LED location DataTransfer Device (DTD) To Reset / Clear Transaction Log • Master Code* (Yellow LED Begins to Blink Slowly) • 76# 00000# 00000# (Yellow LED Blinks Slowly) • * (Yellow LED Begins to Blink Quickly) • * (Yellow LED Goes Out) To Delete a User Number: • User Number# (Yellow LED Blinks Slowly) • * (Yellow LED Begins to Blink Quickly) • * (Yellow LED Blinks Slowly) • * (Yellow LED Goes Out) To Disable / Enable a User Number: • Supervisory or Master Code* (Yellow LED Begins to Blink Slowly) • 56# 0# = Enable, 1# = Disable User Number# (04-99) (Yellow LED Blinks Slowly) • * (Yellow LED Begins to Blink Quickly) • * (Yellow LED Blinks Slowly) • * (Yellow LED Goes Out) To Set Unlock Time: • Master Code* (Yellow LED Begins to Blink Slowly) • 85# Time Duration# (01-99 Sec) 0# (Yellow LED Blinks Slowly) • * (Yellow LED Begins to Blink Quickly) • * (Yellow LED Blinks Slowly) • * (Yellow LED Goes Out) Note: The Unlock Time is Adjustable for Momentary Operation. A 5 second unlock time is recommended to extend battery life. Once the unlock time is entered, it is the same for ALL users except 02, 98 and 99 which are factory set for 10 seconds. 1-800-810-WIRE • www.sargentlock.com • A7373C 21 03/31/14 Copyright © 2014, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. • Master Code* (Yellow LED Begins to Blink Slowly) KP Series Keypad Mortise Lock Transaction Log To output the last 15 entries, enter 99 # Supervisory or Master Code * 70 # 0 # 0 # **. Note: Seq. # 1 is the programming request to output the entries. Sequence numbers 2-6 are the actual entries. Door Number • 4 Digits • Up to 9999 different doors, assigned by user Transaction Number • Single digit - 1-6 Door # 5666 Seq User Trans 1 001 003 • Oldest transaction - 6 2 003 001 User Number • Three digits - 001 through 099 3 003 001 4 020 001 • User numbers assigned at time of programming 5 003 001 Door Number • Latest transaction - 1 Transaction Number Transaction Types • 001 = Access granted Transaction Type User Number • 002 = Access denied (Deadbolt thrown and code entered did not have proper access level.) • 003 = Log printed Optional Equipment Copyright © 2014, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. 03/31/14 Hold an infrared printer up to the red infrared LED (as shown). A Data Transfer Device (DTD) can be used to download information from the keypad to a printout. • Printer Paper (6 Rolls) - 52-0034 used for infrared printers • Auxiliary Power Unit (APU) 52-2065 - used to unlock unit if batteries are too weak and cylinder is not used. Illustration • Data Transfer Device (DTD) - used to download the user and transaction type. • Remote Unlocking - 52-2071 - used for remote unlocking of keypad mortise lock. When the deadbolt is thrown and the remote unlocking feature is used, both the latchbolt and deadbolt can be retracted by turning the lever handle. Remote unlocking connector placement Inside Escutcheon 22 1-800-810-WIRE • www.sargentlock.com • A7373C To LED location DataTransfer Device (DTD) SARGENT Manufacturing Company 100 Sargent Drive New Haven, CT 06511 USA 800-810-WIRE (9473) • www.sargentlock.com Founded in the early 1800s, SARGENT® is a market leader in locksets, cylinders, door closers, exit devices, electro-mechanical products and access control systems for new construction, renovation, and replacement applications. The company’s customer base includes commercial construction, institutional, and industrial markets. Copyright © 2014, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited. ASSA ABLOY is the global leader in door opening solutions, dedicated to satisfying end-user needs for security, safety and convenience. A7373C-03/14
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Create Date : 2014:03:17 15:22:58-04:00 Metadata Date : 2014:04:01 11:18:40-04:00 Modify Date : 2014:04:01 11:18:40-04:00 Creator Tool : Adobe InDesign CC (Windows) Instance ID : uuid:b9772ca1-dab5-4665-bd17-812ca4a74181 Original Document ID : adobe:docid:indd:c6d5a1b8-1ec5-11dc-9031-b975861f0985 Document ID : xmp.id:8177157d-0021-c844-b2a8-24a4fbb7d52b Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:4fa2090b-d25f-1847-94a0-7b55639eca7f Derived From Document ID : xmp.did:4fa2090b-d25f-1847-94a0-7b55639eca7f Derived From Original Document ID: adobe:docid:indd:c6d5a1b8-1ec5-11dc-9031-b975861f0985 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC (Windows) History Changed : / History When : 2014:03:17 15:22:58-04:00 Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Page Count : 23 Creator : Adobe InDesign CC (Windows)EXIF Metadata provided by EXIF.tools