281 DOOR CLOSERS WITH O10, H10 & SSO ARMS
INSTALLATION INSTRUCTIONS
281 SERIES ADJUSTABLE FROM SIZE 1 THRU 6
CAUTION: FAILURE TO INSTALL OR ADJUST PROPERLY MAY RESULT IN INJURY OR DAMAGE.
FOR ASSISTANCE, CALL SARGENT AT 1-800-727-5477.
DRILL AND TAP DOOR
AND FRAME FOR #12-
24 MACHINE SCREWS.
RIGHT HAND SHOWN,
LEFT HAND OPPOSITE.
*NOTE: FOR MAXIMUM
POWER, INSTALL FOR
110° OPENING
PULL SIDE PULL SIDE
PUSH SIDE PUSH SIDE
LEFT HAND DOOR RIGHT HAND DOOR
CLOSERS ARE NON-HANDED
ATTACH ARM TO FACE OF FRAME.
B
RIGHT HAND SHOWN
FOR H10 ARM ONLY
C
INSTALL MOUNTING BRACKET WITH ARROW POINTING UP FOR BOTH RH & LH DOORS. MOUNT CLOSER WITH SPRING
ADJUSTING SCREW AWAY FROM HINGE. SEE PAGE 2 FOR THRU BOLT INFO.
1
ALTERNATE: PREASSEMBLE ARM PRIOR TO
ATTACHING TO STOP.
C1
A
Copyright © 2012, 2014, Sargent Manufacturing Company, an ASSA ABLOY
Group company. All rights reserved. Reproduction in whole or in part without
the express written permission of Sargent Manufacturing Company is prohibited.
A7921C
ACCESSORIES
OPTIONAL: USE MORTISE NUTS (#4TB)
WHEN THRU-BOLTING IS REQUIRED
DA. ATTACH ARM WITH INDEX MARK ON SPINDLE
ALIGNED AS SHOWN BELOW
B. SECURE WITH SCREW AND WASHER.
D1
* WARNING: IF NOT PROPERLY INDEXED, DOOR
CLOSER WILL NOT FUNCTION PROPERLY.
!! !!
ALTERNATE METHOD FOR ATTACHING
PREASSEMBLED ARM
281 DROP PLATE USED WITH NARROW TOP RAILS.
EA. INSTALL PIVOT AS SHOWN
B. USE SCREW TO SECURE PIVOT AND ARMS AS SHOWN
2
CLOSER VALVES
Copyright © 2012, 2014, Sargent Manufacturing Company, an ASSA ABLOY
Group company. All rights reserved. Reproduction in whole or in part without
the express written permission of Sargent Manufacturing Company is prohibited.
A7921C
FINAL ADJUSTMENT AND REGULATING PROCEDURES
F
3
HINSTALL COVER WITH TWO SCREWS AS SHOWN.
SSP INCLUDES HANDED METAL COVER
(NOT SHOWN) AND 6 LOBE SECURITY SCREWS.
GAdjust Closing power to the minimum required to reliably
close and latch door
· If door is hard to open, decrease power slightly
· If door does not latch, increase power as required
· Use the chart below as a starting point
Doors adjusted with high closing power to overcome strong
draft conditions may exceed ADA standards
+-
DOOR WIDTH EXTERIOR DOORS *INTERIOR DOORS
(INCHES)
24-30 Turn screw 2-7 Turn screw 1-5
30-36 Turn screw 7-11 Turn screw 3-6
36-42 Turn screw 11-15 FACTORY SET
42-48 Turn screw 15-17 Turn screw 8 & up
SPRING POWER ADJUSTMENT GUIDELINES
INCREASE
POWER
DECREASE
POWER
ADJUST CLOSING
POWER WITH A 1/4"
HEX WRENCH
· Adjust Door speed, and Latching speed valves to
achieve the desired closing time. Recommend 6
seconds minimum from 90° to the closed position.
· If Backcheck is required, adjust valve to achieve a
slight cushioning effect. Auxiliary stop required
· If closer is equipped with Delayed Action, regulate
valve to achieve the desired delay.
USE 1/8" HEX WRENCH
TO ADJUST VALVES
BACKCHECK
RANGE
DELAYED ACTION
RANGE
CLOSING SPEED
RANGE
LATCHING SPEED
RANGE
Copyright © 2012, 2014, Sargent Manufacturing Company, an ASSA ABLOY
Group company. All rights reserved. Reproduction in whole or in part without the
express written permission of Sargent Manufacturing Company is prohibited.
A7921C
4
Copyright © 2012, 2014, Sargent Manufacturing Company, an ASSA ABLOY
Group company. All rights reserved. Reproduction in whole or in part without
the express written permission of Sargent Manufacturing Company is prohibited.
A7921C
4 5/8"
- -
REVISED TABLE DIMENSION "B", 15" WAS 14"
-A
B
ZONE
10/25/13
REV.
REVISIONS
DESCRIPTION DATE APPROVED
ORIGINAL RELEASE PER PCP07-0047
MOUNTING POSITIONS
MAX. DOOR
OPENING DIM. A DIM. B
110 7 1/2" 15-1/2"
160 4 1/2" 11 1/8"
JCN 2/14/07
Form Rev. 28Oct2005
.
100 Sargent Drive New Haven, CT 06511
B
A
C
D
A
B
C
D
1234
1234
DWG No. SH
1:4
UNLESS OTHERWISE SPECIFIED
REV
RELEASE DATE
1
DWG No.
.XX
1/64
1
.01
FRACTION
ANGLE
A7956
TOLERANCE
2-8-07
2-7-07
2-6-07
DE
ST
GPF
BGS
CONFIDENTIAL
8/10/06
CHECKED BY/DATE
B
TITLE:
SIZE
.XXX
SCALE:
.005
100 Sargent Drive New Haven, CT 06511
DOOR CLOSERS
PER ANSI Y14.5M -1994
COMPANY.
REV
MAT'L
ART.
1of 1
C
PROD CTRL/FNL REL
FNL APPROVAL/DATE
INTERPRET DRAWING
WRITTEN PERMISSION OF THE SARGENT MANUFACTURING
ALL DIMENSION ARE IN INCHES.
FNL APPROVAL/DATE
SARGENT Manufacturing Company
SHEET:
MFG ENG/DATE
DRAWN BY/DATE
281 O10/H10 TEMPLATE
A7956
THIS DOCUMENT IS THE CONFIDENTIAL PROPERTY OF
SARGENT MANUFACTURINGAND IS NOT TO BE REPRODUCED,
USED OR DISCLOSED BY ANYONE WITHOUT THE EXPRESS
TEMPLATE NO
Manufacturing Company
GLASS
OR H10 HEAVY DUTY STANDARD ARM
OF HINGE
281 SERIES DOOR CLOSER WITH O10
12 GAUGE MINIMUM REINFORCEMENT REQUIRED ON METAL DOORS AND FRAMES.
281 COVER
NOTES
3.
DOOR WILL OPEN TO 180° IF CLOSER COVER DOES NOT INTERFERE WITH ADJACENT WALL
4.
A 281-J PLATE MAY BE USED WHEN COVER IS VISIBLE THROUGH GLASS
4
FACE OF DOOR
FRAME REINFORCEMENT
FACE OF FRAME
DOOR
REINFORCEMENT
1.
1
281 MOUNTING PLATE
C
L
2. RIGHT HAND DOOR SHOWN, LEFT HAND OPPOSITE
1
COVER
A7956 B
#12-24 x 5/8" FLAT HEAD
MACHINE SCREWS OR #12 X
1 1/2" SCREWS PROVIDED
#12-24 x 3/4" PAN HEAD
MACHINE SCREWS OR #12 X
1 1/2" SCREWS PROVIDED
3
DIM. "B"
DIM "A"
2 7/8"
10 3/8"
1/4"
MIN RAIL
2 3/16"
1"
MAX REVEAL
1 1/4"
2 1/2"
12"
7/8"
13/16"