Savant Technologies GE Lighting a Savant WIT100 Wireless Integrated Thread Sensor User Manual WIT100 Install Manual English 031918
GE Lighting Wireless Integrated Thread Sensor WIT100 Install Manual English 031918
Users Manual
Installation Guide WIT100 Sensor Wireless Integrated Thread Sensor STOP BEFORE YOU BEGIN Read these instructions completely and carefully. WARNING RISK OF ELECTRIC SHOCK In case of Digital bus miswiring mains can present on the device. Make sure all electricity switched of before inspection. • Turn power off before inspection, installation or removal RISK OF FIRE • Follow all relevant IEC or UL instructions and local building codes IMPORTANT To ensure the product warranty is valid, please ensure all installation instructions and environmental conditions for storage and operation are complied with. Only GE trained contractors can install the product. FCC / IC COMPLIANCE STATEMENTS This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This device complies with Industry Canada license exempt RSS standards. Operation is subject to the following two conditions: • This device may not cause harmful interference, and • This device must accept any interference received, including interference that may cause undesired operation. Cet appareil est conforme aux normes RSS exemptées de licence de Industrie Canada. Son fonctionnement est soumis aux deux conditions suivantes: • Cet appareil ne doit pas provoquer d'interférences et • Cet appareil doit accepter toute interférence, y compris celles pouvant causer un mauvais fonctionnement de l'appareil. To satisfy FCC/ISED RF exposure requirements a separation distance of 20 cm or more must be maintained between the antenna of this device and persons during operation. Operation at closer than 20cm is not permitted Pour être conforme aux limites d’exposition aux ondes RF des normes FCC/ISED, une distance de séparation d’au moins 20 cm doit être maintenue entre l’antenne de cet appareil et toute personne pendant son opération. Mettre en opération cet appareil a une distance plus rapprochée que 20 cm n’est pas permis. Product overview The Wireless Integrated Therad sensor (WIT100) is a small-size, luminaire-integrated sensor with wireless communication, using the cutting-edge Thread protocol. This is based on the 802.15.4 standard and guarantees a secure and reliable communication between the luminaires in the room. Using the WIT100 sensor in each luminaire provides a state-of-the-art distributed lighting control based on the built-in motion sensing and daylight harvesting functionalities. This sensed information is then shared between all luminaires. The control of the luminaire is carried out through the DALI 2.0 digital bus between the output of the sensor and the control input of the luminaire’s LED driver. The DALI bus also provides the necessary supply power for the sensor, no any additional wiring and auxiliary power supply is required. This and the wireless communication help minimizing the installation costs. Besides the automatic operation of the system it is also possible to adjust preferred dimming levels manually through Current’s energy-harvesting wireless switches. These switches do not require wires for communication, but they even use the mechanical energy of pushing the button to generate the necessary power for the electronics. The configuration of the system is done in a very easy way using through Current’s Bluetooth-based iOS application. Techical data Key functions Dimensions 58,5 x D35mm (2,303xD1,378 inch) + connected cable Weight 15g Current consumption Max 8mA (without digital communication) @ Max. 20V DC Sensor type Passsive infrared (PIR) sensor (for motion), light sensor Operating Environment 0°C to 45°C / IP 20 – Indoor, dry location. Status indicator Network LED (amber): Network joined; Installation test Connections Cable connection to the Driver or Interface module. Mounting Easy screwless installation to a D22mm (0,866 inch) cut hole. Recomented mounting height 3m Warranty 5 years Product Certifications E486320 FCC ID: PUU-WIT100 IC ID: 10798A-PUUWIT100 Product availability SKU Description Article No. TBD Wireless Integrated Thread Sensor WIT100 Notes Purpose of the Control Operating Control Method of Mounting Control Independently Mounted Control for panel mounting Type of action and additional features Type 1 Control Pollution Degree Software Class and Structure Class A Maximum Interconnection cables length 3m Dimensions Sensor pattern Cable connection to driver Connect the WIT100 Sensor Digital bus line with a TE770340 / TE350628 connector to the bellow drivers and interface module: • Connected Indoor Driver (CID): limited compatibility to allow proper operation of fixture (OFF, backround level dim and task level lighting) • Philips Sensor Ready driver (SR): compatibility desirable but not required • Leedarson 0-10V/DALI interface module: ON/OFF and dimming commands only (no Fault Reporting, no VLC, no Dimming Curve Change, and OTA no 1% diming, partial UL924) Cable from Driver/Interface module www.currentbyge.com All trademarks are the property of their respective owners. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions. Current, powered by GE is a business of the General Electric Company. © 2016 GE. WIT100 Sensor Install Manual (GE2033-0758 / SAPXXXXXXXX)
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : xuji Create Date : 2018:03:29 15:59:29-04:00 Modify Date : 2018:03:29 15:59:29-04:00 XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Metadata Date : 2018:03:19 13:27:28+01:00 Creator Tool : Adobe InDesign CC 13.1 (Windows) Instance ID : uuid:3a4a594f-f90f-462f-96c2-9965120a7aab Original Document ID : xmp.did:b5348944-6c98-4849-82e8-67936dbbd839 Document ID : xmp.id:60ec3f86-6d74-954b-bdd1-278cdb0d8724 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:0d06d7ff-8578-6d4e-af8e-ed07bd16f183 Derived From Document ID : xmp.did:59974c32-4d4d-2641-8d7c-f66a3d6fb95a Derived From Original Document ID: xmp.did:b5348944-6c98-4849-82e8-67936dbbd839 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 13.1 (Windows) History Changed : / History When : 2018:03:19 13:27:27+01:00 Format : application/pdf Title : WIT100 Install Manual English 031918.pdf Creator : xuji Producer : Acrobat Distiller 10.1.16 (Windows) Trapped : False Page Count : 3EXIF Metadata provided by EXIF.tools