Schlage Electronic Security BR100 Z-Wave to Ethernet Bridge User Manual link system setup 7 indd

Schlage Electronic Security Z-Wave to Ethernet Bridge link system setup 7 indd

Exhibit D Users Manual per 2 1033 b3

Download: Schlage Electronic Security BR100 Z-Wave to Ethernet Bridge User Manual link system setup 7 indd
Mirror Download [FCC.gov]Schlage Electronic Security BR100 Z-Wave to Ethernet Bridge User Manual link system setup 7 indd
Document ID1020466
Application IDvjYJCgZF19l7tRwVHR+fkQ==
Document DescriptionExhibit D Users Manual per 2 1033 b3
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize400.32kB (5004015 bits)
Date Submitted2008-10-24 00:00:00
Date Available2008-10-24 00:00:00
Creation Date2008-10-10 13:17:06
Producing SoftwareAcrobat Distiller 8.1.0 (Windows)
Document Lastmod2008-10-10 13:17:06
Document Titlelink system setup-7.indd
Document CreatorPScript5.dll Version 5.2.2
Document Author: mmcnatt

System Setup
The lock should already be installed on your door. If not,
use the installation instructions (document number 2 )
to install the lock and then come back to this document.
Important Information
Lock Programming Code
six (6) digits
Bridge MAC ID
OR
twelve (12) characters
Web Support: testmydoorlock.com
Customer Service: (877) 288-7707
Locate the programming code, on top of document 2 .
Write the programming code in the “Important Information”
box at the top of this page.
• The programming code can be changed. If you have changed
your programming code, the code that is printed on the label
will not work. (See Manual Programming and Troubleshooting at
testmydoorlock.com.)
• If you don’t remember your programming code, you can reset your
lock, which will restore the original programming code. (See Manual
Programming and Troubleshooting at testmydoorlock.com.)
Códigos
preajustados
Programming Code
Código de programación
Code de programmation
Prog Code XXXXXX (FCC ID: P2GXXXXX)
User Code A XXXX XXXXX
User Code B XXXX SN XXXXXXXXX
User Codes
Códigos de usuario
Codes utilisateur
• The programming code is six digits long and is located on the
yellow sticker on the installation sheet that is packed in the box.
P515-861
Preset
Codes
Installation Instructions
Instrucciones de instalación
Notice d'installation
Préréglage
des codes
Serial Number
Número de serie
Numéro de série
Lock Model
Modelo de la cerradura
Modèle de serrure
2³⁄₈” (60 mm)
Top
Parte superior
Haut
2³⁄₄” (70 mm)
OR
OU
Prog Code XXXXXX (FCC ID: P2GXXXXX)
User Code A XXXX XXXXX
User Code B XXXX SN3 XXXXXXXXX
OR
Top
Parte superior
Haut
OR
OU
OU
Without these user codes,
you can get locked out.
Si no cuenta con estos
códigos de usuario, es
posible que no pueda
abrir.
Vous ne pouvez entrer
sans déverrouiller à l'aide
des codes d'utilisateur.
Alternate Faceplate
Chapa frontal alterna
Plateau à trous alternatif
2 ³⁄₄
180°
(2)
Choose Faceplate to Match Door
Escoja la placa delantera para emparejar la puerta
Choisir la têtière pour égaler la porte
OR
OU
Instalación de la cerradura
Install Lock
Precaución
Installer le verrou
2³⁄₈” (60 mm)
OR O OU
2³⁄₄” (70 mm)
Check Dimensions
Revise las dimensiones
Vérifier les dimensions
Caution
2¹⁄₈” (53 mm)
Hole
Agujero
Trou
5¹⁄₂” (140 mm)
Minimum
Mínimo
Minimum
Locate the bridge MAC ID. Write the MAC ID in the
“Important Information” box at the top of this page.
• The MAC ID is 12 characters long and is located on the yellow label
inside the battery compartment of the bridge.
D: XX
C I XX
MA XXX
XX
Mise en garde
Match arrows
Las flechas deben quedar alineadas
Aligner les flèches
3
Install the light module.
• The light module also repeats the Z-Wave signal. If the final
location of the bridge (where it can be connected to your router) is
more than 60 feet (18 meters) from the lock, use an outlet that is
approximately half way between the lock and the bridge.
• The light module should be installed into any indoor, three-prong,
120 volt A/C outlet.
Plug a lamp into the Z-Wave side of the light module.
• There are two outlets on the light module. One of the outlets has
only two prongs and is labelled with a Z-Wave sticker. A lamp (25
watts minimum and 300 watts maximum) must be plugged in to the
Z-Wave side of the light module for proper operation.
• Use only an incandescent light bulb in the lamp that is plugged into
the light module. DO NOT use a CFL (compact fluorescent light
bulb).
• The other outlet has three prongs and can be used simply as an
outlet (1500 watts maximum). It is not controlled by the system, and
the system is not affected when it is used.
Install the 9 volt battery into the bridge.
• Use the 9 volt battery that is included in the box.
• Use any premium quality 9 volt battery for replacement.
Max. 300W
Incandescent
6
Enroll the light module into the bridge.
a. Hold the bridge within 6 feet (1.8 meters) of the light
module throughout all of step 6.
b. Press and release the plus (+) button on the bridge.
c. Double-click the button on the light module.
d. Observe the lights on bridge. The orange light will blink
while enrollment is taking place. Enrollment is complete
when the orange light becomes solid.
Enroll the lock into the bridge.
a. Hold the bridge within 6 feet (1.8 meters) of the lock
throughout all of step 7.
b. Press and release the plus (+) button on the bridge. You
have 30 (thirty) seconds to complete the remainder
of the steps.
c. On the lock keypad, press the six-digit programming
code (located in the “Important Information” box).
d. Wait for the lock to beep three times and the Schlage
button on the lock to flash orange three times.
e. On the lock keypad, press the Schlage button and then
the 0 (zero) button. The lock will begin to beep.
f. On the lock keypad, observe the Schlage button. If the
Schlage button flashes green, enrollment was successful. If the Schlage button flashes red, enrollment was
unsuccessful and you should start over at step 7a.
• If enrollment is unsuccessful multiple times, call customer service (877-288-7707).
g. Observe the lights on bridge. The orange light will blink while enrollment is taking place. Enrollment is
complete when the orange light becomes solid.
This portion of the setup is complete. For the next portion, please ensure that you have one of the following
browsers installed on your computer:
● Internet Explorer 7.0 (http://www.microsoft.com/windows/downloads/ie/getitnow.mspx)
● Firefox 3.0 (http://www.mozilla.com)
For troubleshooting, see testmydoorlock.com.
Using either Internet Explorer 7.0 or Firefox 3.0, browse to www.schlagelink.com
and follow the on-screen instructions.
This device complies with Part 15 of the FCC Rules. Operation is subject
to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
FCC ID: P2GBE369
FCC ID: P2GFE369
FCC ID: P2GBR100
PATENT NOTICE
Schlage® products and those of its subsidiary companies and licensees
may be covered by both issued and pending U.S. and foreign patents,
copyrights and trademarks. Manufactured items are covered by one or
more of the following patents:
D458829
D372417
6523375
5070715
5765412
5152558
5769472
6533336
D372854
D467155
5308131
5809816
6540274
D406056
D472788
5395144
5816086
6581426
D406528
D487388
5593193
5820290
6802546
D426452
D520331
5598726
5881590
6905773
D428324
D520332
5640863
5918916
6926319
D450558
D537702
5683127
6286347
7143477
D457048
D541620
5715717
6297725
7159424
D457049
D543435
the Product. No action arising out of any claimed breach of this warranty
by Schlage may be brought by the Original User more than one (1) year
after the cause of action has arisen.
How local law applies: This warranty gives you specific legal rights,
and you may also have other rights as otherwise permitted by law. If this
Product is considered a consumer product, please be advised that some
local laws do not allow limitations on incidental or consequential damages
or how long an implied warranty lasts, so that the above limitations may
not fully apply. Refer to your local laws for your specific rights under this
warranty.
Guaranteed Fit Program: Schlage products are designed to fit standard
residential door preparations and retrofit existing tubular locks. Note:
Mortise locks and preparations are not considered standard and are not
guaranteed under this program. During the initial installation, if there is
a problem with the Product’s performance, the Original User may simply
contact Schlage Customer Service at 888-805-9837 in the U.S. and
Canada or 800-506-7866 in Mexico for assistance.
Program and warranty claims: If you encounter a residential door
preparation or fit issue under the Guaranteed Fit Program or have a claim
under this warranty, please contact Schlage Customer Service for repair,
replacement or refund of the original purchase price in exchange for the
return of the Product to Schlage
Lifetime Limited Mechanical and Finish Warranty and 1-Year Limited
Electronics Warranty
Subject to the terms and conditions of this warranty, Schlage extends
a lifetime limited mechanical and finish warranty and a one-year limited
electronics warranty to the original consumer user (“Original User”) of
our Schlage brand product (“Product”) against defects in material and
workmanship, as long as the Original User occupies the residential
premises upon which the Product was originally installed.
What Schlage will do: Upon return of the defective Product to Schlage,
Schlage’s sole obligation, at its option, is to either repair or replace
the Product, or refund the original purchase price in exchange for the
Product.
Original User: This warranty only applies to the Original User of Products.
This warranty is not transferable.
What is not covered: The following costs, expenses and damages are
not covered by the provisions of this limited warranty: (i) labor costs
including, but not limited to, such costs as the removal and reinstallation
of Product; (ii) shipping and freight expenses required to return Product to
Schlage; (iii) failures, defects, or damage (including, but not limited to, any
security failure or loss of data) caused by any third party product, service,
or system connected or used in conjunction with the Product; and (iv) any
other incidental, consequential, indirect, special and/or punitive damages,
whether based on contract, warranty, tort (including, but not limited to,
strict liability or negligence), patent infringement, or otherwise, even if
advised of the possibility of such damages. Some local laws do not allow
the exclusion or limitation of incidental or consequential damages, so the
above exclusion or limitation may not apply to you.
The provisions of this warranty do not apply to Products: (i) used in
commercial applications; (ii) used in common area applications; (iii) used
for purposes for which they are not designed or intended; (iv) which have
been subjected to alteration, abuse, misuse, negligence or accident; (v)
which have been improperly stored, installed, maintained or operated;
(vi) which have been used in violation of written instructions provided
by Schlage; (vii) which have been subjected to improper temperature,
humidity or other environmental conditions; or (viii) which, based on
Schlage’s examination, do not disclose to Schlage’s satisfaction nonconformance to the warranty. Additionally, this warranty DOES NOT
COVER scratches, abrasions, or deterioration due to the use of paints,
solvents or other chemicals.
Exclusions: Oil Rubbed Bronze finish (613) is designed to improve
over time and change in appearance, creating a living finish through
daily use and thus, finish discoloration is not applicable to the above
warranty.
Additional terms: Schlage does not authorize any person to create
for it any obligation or liability in connection with the Product. Schlage’s
maximum liability hereunder is limited to the original purchase price of
©2008 Schlage Lock Company
link system setup Rev. 10/08-7

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2008:10:10 13:17:06-06:00
Create Date                     : 2008:10:10 13:17:06-06:00
Format                          : application/pdf
Title                           : link system setup-7.indd
Creator                         : mmcnatt
Producer                        : Acrobat Distiller 8.1.0 (Windows)
Document ID                     : uuid:f38a97c4-496e-4e58-9056-28d3740c3608
Instance ID                     : uuid:93fde4dc-69f6-4fa5-88f2-6627c247cb8f
Page Count                      : 4
Author                          : mmcnatt
EXIF Metadata provided by EXIF.tools
FCC ID Filing: P2GBR100

Navigation menu