Schlage Electronics Solution Sheet Lenel AD 300 400 105080
User Manual: Schlage Electronics Solution Sheet Lenel AD 300 AD 400 Data Sheets
Open the PDF directly: View PDF .
Page Count: 4
Download | |
Open PDF In Browser | View PDF |
Integrated security solution with AD-400 wireless devices, AD-300 hardwired locks and Lenel OnGuard® Overview Schlage AD Series hardwired and wireless locks seamlessly integrate with Lenel OnGuard® (version 6.6 SP1 or higher) to provide a cost effective and scalable access control solution. System Capabilities Summary §§ §§ AD Series wireless locks combine the components typically found around the door, such as the door position switch and the request-to-exit switch, into one unit which simplifies installation and saves money. And since they are designed to be modular, Schlage AD Series locks can easily be upgraded in the future to meet your changing security and technology requirements. AD-400 wireless: −− Secure 900 MHz wireless communication, AES-128 encrypted −− Real time access control and monitoring −− Powered by four (4) standard off-the-shelf AA batteries −− Lenel OnGuard supports Remote Linking of AD-400 wireless locks OnGuard® offers advanced access control, alarm monitoring, digital video, intrusion detection, asset tracking, information security integration, credential production, and employee and visitor management functionality. Individual application modules are available as standalone systems or can be deployed in any combination to deliver a single, seamlessly integrated solution. The AD Series is available in both hardwired and wireless configurations to suit the requirements of the facility. AD Series wireless locks provide many of the key benefits of a hardwired system including real-time monitoring, audit trails, centralized lockdown and instant access control management. In retrofit applications, the Schlage AD Series wireless locks and device, which eliminate the need to run wires direct to each opening, can help you extend the reach of your access control system. AD-300 hardwired: −− Field configurable fail safe/fail secure §§ Patent pending wireless lockdown/unlock feature via PIM400 (10 seconds or less preserves up to 2 year battery life §§ Additional details on readers supported and chassis types available on page 3 and 4 §§ Weather resistant, exterior operating temperature: -31° to 151°F (-35° to 66°C) §§ Additional wireless products also available −− Wireless Portable Reader (WPR400) for muster stations, buses, etc. −− Wireless Reader Interface (WRI400) −− Eliminate running wires to remote doors, gate, and elevator applications §§ ANSI/BHMA A156.25, ANSI/BHMA Grade 1, UL 294, UL 10C AD-400 via RS-485 §§ LNL-3300 supports up to 64 AD Series locks total §§ LNL-3300 supports a maximum of 8 PIM400-485s or AD-300s per RS-485 port There are 2 ports on each LNL-3300 §§ Wireless range up to 200’ in building construction, up to 1000’ line of sight Schlage protocol RS-485 Rev. 6.6 SP1 or higher Ethernet Lenel OnGuard® System Firmware Rev 1.188 or higher 900 MHz Schlage protocol RS-485 LNL-3300 Intelligent system controller NOTE: Although not specifically shown, both AD-300s and AD-400s can be managed on a common port AD-400 Wireless devices PIM400-485 Panel interface module 900 MHz AD-400 Wireless devices PIM400-485 Panel interface module AD-400 via PIM400-1501 (PIM400-485 plus LNL-2210 in same enclosure) §§ PIM400-1501 supports up to 16 AD-400 devices §§ Wireless range Up to 200’ in building construction, up to 1000’ line of site 1 In order to have a UL Listed configuration a UL294 12VDC power supply must be used instead of PoE Rev. 6.6 SP1 or higher PoE (Power Over Ethernet) Ethernet 900 MHz PoE network switch1 Lenel OnGuard® System PIM400-1501 AD-400 Wireless devices AD-300 via RS-485 with LNL-3300 §§ LNL-3300 supports up to 16 AD-300 locks (up to 8 AD-300 locks on each RS-485 port) NOTE: Although not specifically shown, both AD-300s and AD-400s can be managed on a common port Schlage protocol RS-485 Rev. 6.6 SP1 or higher Firmware Rev 1.188 or higher Ethernet Lenel OnGuard System AD-300 Hardwired devices ® LNL-3300 Intelligent system controller AD-300 Hardwired devices AD-300/301 via RS-485 with LNL-2210 §§ LNL-2210 can control a total of 8 AD-300/301 on a common RS-485 data line §§ LNL-2210 can PoE (Power Over Ethernet) 2 AD-300/301 §§ Remaining 6 AD-300/301 will be powered from an external 12/24VDC power supply. Rev. 6.6 SP1 or higher Lenel OnGuard® System PoE (Power Over Ethernet) Ethernet PoE network switch1 Firmware Rev 1.187 or higher LNL-2210 Contact Lenel when designing or adding on to a current system that currently uses the LNL-500W to support the AD-400. Note: Please refer to AD-300, AD-400, PIM400-485, PIM400-TD2, PIM400-1501, WPR400, and WRI400 data sheets for complete AD Series specifications For additional information contact Lenel: 1.800.631.6046 or www.lenel.com AD-300/301 Hardwired devices System capabilities: AD-400 PIM400-485 (LNL-3300) AD-400 PIM400-1501 (PIM400-485 + LNL-2210) AD-300 Direct RS-485 (LNL-3300) AD-300 (LNL-2210) Maximum number of readers supported by controller/PIM 64 16 16 8 AD-300 (LNL-2210 can PoE (Power Over Ethernet) 2 AD-300/301) Maximum number of readers per PIM400 16 16 N/A N/A Maximum number of PIM400s and/or AD-300s per RS-485 port Up to 8 N/A Up to 8 Up to 8 Access control decision made by host or by lock database Host Host Host Host Remote Linking capability via Host Yes Yes N/A N/A Keypad only Yes (up to 9 digits) Yes (up to 9 digits) Yes (up to 9 digits) Yes (up to 9 digits) Magnetic stripe card Yes Yes Yes Yes Multi-technology - 125 kHz proximity and 13.56 MHz smart card Yes Yes Yes Yes PIV & PIV-I card compatible1 Yes Yes Yes Yes Card + PIN Yes (up to 9 digits) Yes (up to 9 digits) Yes (up to 9 digits) Yes (up to 9 digits) Request to exit Yes Yes Yes Yes Door position Yes Yes Yes Yes Mechanical key override Yes Yes Yes Yes Request to enter No No No No Low battery status Yes Yes N/A N/A Communication status: RF/RS-485 Yes /Yes Yes/Yes Yes Yes Remote lockdown/unlock Yes (<10 sec)2 Yes (<10 sec)2 Yes Yes Deadbolt position Yes Yes Yes Yes Interior push button Yes Yes Yes Yes Classroom/storeroom Yes Yes Yes Yes Office/toggle Yes Yes Yes Yes Privacy Yes Yes Yes Yes Apartment Yes Yes Yes Yes Features Readers - see supported card formats below Status monitors Lock functions Please contact Lenel for additional details on integrated features and credentials supported. Supported card formats Proximity cards (125 kHz): §§ AWID® §§ GE/CASI® §§ HID® §§ Schlage® §§ XceedID® Smart cards (13.56 MHz): §§ aptiQ MIFARE Classic §§ aptiQ MIFARE DESFire EV1 §§ PIV and PIV-I compatible1 Smart cards (13.56 MHz) reads card serial number only: §§ HID iCLASS® §§ DESFire® §§ MIFARE® §§ MIFARE DESFire™ EV1 1 FIPS-201-1 compliant option available requires FMK reader: The AD Series can be used in applications which require approval by the U.S. Federal Government under HSPD-12 for FIPS 201-1 compliance. Specific components are required, please see the AD-401 and AD-301 data sheet for complete details. Contact Lenel to confirm they are able to support your FIPS 201-1 credential format. 2 For greater than 1 device will be <20 sec For additional information contact Lenel: 1.800.631.6046 or www.lenel.com Available AD Series reader modules Multi-technology Multi-technology §§ Proximity §§ Smart card §§ Proximity §§ Smart card + KEYPAD Magnetic stripe (insertion) + Magnetic stripe (insertion) KEYPAD Magnetic stripe (swipe) + Keypad Magnetic stripe (swipe) KEYPAD Used to initialize, configure, and test AD Series Devices FIPS 201-1 compliant option available (FMK) Compatibility Mortise Lock (AD-300/400) Handheld device (HHD) Cylindrical Lock (AD-300/400) Exit Device Trim (AD-300/400-993) AD Series electronic locks from Schlage are built from the ground up to provide more options, more functionality and more compatibility than any other solution on the market today. Designed to suite with the most popular lever styles and finishes, Schlage AD Series locks can be configured to accept most major key systems. See lever and cylinder compatibility data sheet (010432). The AD Series exit trims are exclusively compatible with exit devices made by Allegion when using the low current request to exit switch (RX-LC part # 050281 for Von Duprin 98/99 & Von Duprin 22/22F Rim/SVR devices and part number 650359 for Falcon 25 Rim devices). Lever styles Finishes Standard cylinders shown, SFIC and FSIC also available. Warm tone finishes Sparta Rhodes 605 Bright brass Athens Tubular 606 Satin brass Cool tone finishes 612 Satin bronze 643e Aged bronze 619 Satin nickel 625 Bright chrome 626 Satin chrome 626AM Satin chrome with antimicrobial Allegion, the Allegion logo, Schlage, the Schlage logo, Von Duprin, Falcon, and aptiQ are trademarks of Allegion plc, its subsidiaries and/or affiliates in the United States and other countries. All other trademarks are the property of their respective owners. About Allegion Allegion (NYSE: ALLE) is a global pioneer in safety and security, with leading brands like CISA®, Interflex®, LCN®, Schlage® and Von Duprin®. Focusing on security around the door and adjacent areas, Allegion produces a range of solutions for homes, businesses, schools and other institutions. Allegion is a $2 billion company, with products sold in almost 130 countries. For more, visit www.allegion.com. © 2015 Allegion 005080, Rev. 08/15 www.allegion.com/us For additional information contact Lenel: 1.800.631.6046 or www.lenel.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27 Create Date : 2015:09:22 14:06:41-05:00 Metadata Date : 2015:09:22 14:07:11-05:00 Modify Date : 2015:09:22 14:07:11-05:00 Creator Tool : Adobe InDesign CS6 (Macintosh) Instance ID : uuid:fe448867-1d00-d04a-82a2-7487be213235 Original Document ID : xmp.did:1B9DBD0D2A2068119A82B324BB5F3DDD Document ID : xmp.id:AA8F6E0E83206811822ABDEE02568EF3 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:90A8EA750F206811822AF69868873BD1 Derived From Document ID : xmp.did:15F4A26458206811822A9AC81F4D062B Derived From Original Document ID: xmp.did:1B9DBD0D2A2068119A82B324BB5F3DDD Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Macintosh) History Changed : / History When : 2015:09:22 14:06:41-05:00 Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Page Count : 4 Creator : Adobe InDesign CS6 (Macintosh)EXIF Metadata provided by EXIF.tools