Schlage Electronics S2 Security Access Control Solution Sheet With AD 400 109822
User Manual: Schlage Electronics S2 Security Access Control Solution Sheet with AD-400 Data Sheets
Open the PDF directly: View PDF .
Page Count: 4
Download | |
Open PDF In Browser | View PDF |
Integrated security solution with AD-400 wireless devices and S2 NetBox Overview Schlage AD Series locks seamlessly integrate with S2 NetBox to provide a cost effective and scalable access control solution to meet your security needs. System Capabilities Summary §§ AD-400 wireless: −− Secure 900 MHz wireless communication, AES-128 bit encrypted −− Real time access control and monitoring −− Powered by four (4) standard off-theshelf AA batteries −− Patent pending wireless lockdown/unlock feature via PIM400 (10 seconds or less) preserves up to 2 year battery life §§ Additional details on readers supported and chassis types available on page 3 and 4 §§ Weather resistant, exterior operating temperature: -31° to 151°F (-35° to 66°C) §§ Additional wireless products also available −− Wireless Portable Reader (WPR400) for muster stations, buses, etc. −− Wireless Reader Interface (WRI400) Eliminate running wires to remote doors, gate, and elevator applications §§ ANSI/BHMA A156.25, ANSI/BHMA Grade 1, UL 294, UL 10C Schlage AD Series locks combine the components typically found around the door, such as the door position switch and the request to exit switch, into one unit which simplifies installation and saves money. And since they are designed to be modular, Schlage AD Series locks can easily be upgraded in the future to meet your changing security and technology requirements. The AD Series is available in wireless configurations to suit the requirements of the facility. AD Series wireless locks provide many of the key benefits of a hardwired system including real-time monitoring, audit trails, centralized lockdown and instant access control management. In retrofit applications the Schlage AD Series wireless locks and devices, which eliminate the need to run wires direct to each opening, can help you extend the reach of your access control system. AD-400 via RS-485 with S2 NetBox and S2-EP2500 §§ S2-EP2500 supports up to 64 total locks §§ S2-EP2500 supports a maximum of 8 PIM400-485 per RS-485 port. There are 2 RS-485 ports on each S2-EP2500. §§ Wireless range up to 200’ in typical building construction, up to 1000’ line of sight Schlage protocol Ethernet Firmware Version 1.18.5 or greater NetBox Controller Rev 4.5 or higher 900 MHz RS-485 PIM400-485 Panel interface module RS-485 AD-400 Wireless devices S2-EP2500 900 MHz PIM400-485 Panel interface module AD-400 Wireless devices AD-400 via PIM400-1501 with S2 NetBox §§ PIM400-1501 supports up to 16 AD-400s §§ Wireless range up to 200’ in typical building construction, up to 1000’ line of sight 1 In order to have a UL Listed configuration a UL294 12VDC power supply must be used instead of PoE Power Over Ethernet (PoE) Ethernet 900 MHz NetBox Controller Rev 4.5 or higher PoE network switch1 PIM400-1501 Intelligent controller AD-400 Wireless devices AD-400 via Wiegand with S2 NetBox and EP-1502 §§ EP1502 supports 2 AD-400 wireless locks via PIM400-TD2 §§ Wireless range up to 200’ in typical building construction, up to 1000’ line of sight Ethernet Wiegand 900 MHz NetBox Controller Rev 4.5 or higher EP-1502 Note: Please refer to AD-400, PIM400-485, PIM400-1501, PIM400-TD2 and WRI400 data sheets for complete AD Series specifications For additional information contact S2 Security: www.s2sys.com or 508.663.2505 PIM400-TD2 Panel interface module AD-400 Wireless devices System capabilities: AD-400 PIM400-485 AD-400 PIM400-1501 AD-400 EP-1502/PIM400-TD2 Maximum number of readers supported by controller/PIM 64 16 2 Maximum number of readers per PIM400 Up to 16 Up to 16 Up to 2 Maximum number of PIM400s per RS-485 port Up to 8 N/A N/A Access control decision made by host or by lock database Host Host Host Remote Linking capability via Host No No No Keypad only No No No Magnetic stripe card Yes Yes Yes Multi-technology - 125 kHz proximity and 13.56 MHz smart card Yes Yes Yes PIV & PIV-I card compatible1 Yes Yes Yes Card + PIN Yes (up to 6 digits) Yes (up to 6 digits) Yes (up to 6 digits) Request to exit Yes Yes Yes Door position Yes Yes Yes Mechanical key override Yes Yes No Request to enter No No No Low battery status Yes Yes No Communication status: RF/RS-485 Yes /Yes Yes/Yes Yes Remote lockdown/unlock2 Yes (<10 sec) 2 Yes (<10 sec) 2 Yes Deadbolt position Yes 3 Yes 3 Yes 3 Interior push button Yes 3 Yes 3 Yes 3 Features Readers - see supported card formats below Status monitors Lock functions Storeroom Yes Yes Yes Office Yes 3 Yes 3 Yes 3 Privacy Yes 3 Yes 3 Yes 3 Apartment Yes 3 Yes 3 Yes 3 Please contact S2 Security for additional details on integrated features and credentials supported. 1 Supported card formats Proximity cards (125 kHz): §§ AWID® §§ GE/CASI® §§ HID® §§ Schlage® §§ XceedID® Smart cards (13.56 MHz): §§ aptiQ™ MIFARE Classic §§ aptiQ™ MIFARE DESFire™ EV1 §§ PIV and PIV-I compatible 1 Smart cards (13.56 MHz) reads card serial number only: §§ HID iCLASS® §§ DESFire® §§ MIFARE® §§ MIFARE DESFire™ EV1 FIPS-201-1 compliant option available requires FMK reader: The AD Series can be used in applications which require approval by the U.S. Federal Government under HSPD-12 for FIPS 201-1 compliance. Specific components are required, please see the AD-401 and AD-301 data sheet for complete details. Contact S2 Security to confirm they are able to support your FIPS 201-1 credential format. 2 For greater than 1 device will be <20 sec 3 Requires NetBox Controller version 4.7 or higher For additional information contact S2 Security: www.s2sys.com or 508.663.2505 Available AD Series reader modules Multi-technology Multi-technology §§ Proximity §§ Smart card §§ Proximity §§ Smart card + KEYPAD Magnetic stripe (insertion) + Magnetic stripe (insertion) KEYPAD Magnetic stripe (swipe) + Handheld device (HHD) Magnetic stripe (swipe) KEYPAD Used to initialize, configure, and test AD Series Devices FIPS 201-1 compliant option available (FMK) Compatibility Mortise Lock (AD-400-MS) Cylindrical Lock (AD-400-CY) Exit Device Trim (AD-400-993) AD Series electronic locks from Schlage are built from the ground up to provide more options, more functionality and more compatibility than any other solution on the market today. Designed to suite with the most popular lever styles and finishes, Schlage AD Series locks can be configured to accept most major key systems. See lever and cylinder compatibility data sheet (010432). The AD Series exit trims are exclusively compatible with exit devices made by Allegion when using the low current request to exit switch (RX-LC part # 050281 for Von Duprin 98/99 & Von Duprin 22/22F Rim/SVR devices and part number 650359 for Falcon 25 Rim devices). Lever styles Finishes Standard cylinders shown, SFIC and FSIC also available. Warm tone finishes Sparta Rhodes 605 Bright brass Athens Tubular 606 Satin brass Cool tone finishes 612 Satin bronze 643e Aged bronze 619 Satin nickel 625 Bright chrome 626 Satin chrome 626AM Satin chrome with antimicrobial Allegion, the Allegion logo, Schlage, the Schlage logo, Von Duprin, Falcon, and aptiQ are trademarks of Allegion plc, its subsidiaries and/or affiliates in the United States and other countries. All other trademarks are the property of their respective owners. About Allegion Allegion (NYSE: ALLE) is a global pioneer in safety and security, with leading brands like CISA®, Interflex®, LCN®, Schlage® and Von Duprin®. Focusing on security around the door and adjacent areas, Allegion produces a range of solutions for homes, businesses, schools and other institutions. Allegion is a $2 billion company, with products sold in almost 130 countries. For more, visit www.allegion.com. © 2015 Allegion 009822, Rev. 08/15 www.allegion.com/us For additional information contact S2 Security: www.s2sys.com or 508.663.2505
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27 Create Date : 2015:09:22 15:19:11-05:00 Metadata Date : 2015:09:22 15:19:31-05:00 Modify Date : 2015:09:22 15:19:31-05:00 Creator Tool : Adobe InDesign CS6 (Macintosh) Instance ID : uuid:025ed5bd-cccb-9a42-b8dc-3a6924e85297 Original Document ID : xmp.did:1B9DBD0D2A2068119A82B324BB5F3DDD Document ID : xmp.id:10B472278D206811822ABDEE02568EF3 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:0FB472278D206811822ABDEE02568EF3 Derived From Document ID : xmp.did:B0A7FED166206811822A9AC81F4D062B Derived From Original Document ID: xmp.did:1B9DBD0D2A2068119A82B324BB5F3DDD Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Macintosh) History Changed : / History When : 2015:09:22 15:19:11-05:00 Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Page Count : 4 Creator : Adobe InDesign CS6 (Macintosh)EXIF Metadata provided by EXIF.tools