1                            Wiser CT Specification Contents 1 General Features .................................................................................................................................. 2 1.1 System ........................................................................................................................................... 2 1.2 Metering Measurements ............................................................................................................... 2 1.3 Power Supply ................................................................................................................................. 2 1.4 Memory Backup ............................................................................................................................. 2 1.5 Indicator ........................................................................................................................................ 2 1.6 ZigBee ............................................................................................................................................ 2 2 Environmental Requirements ............................................................................................................... 3 2.1 Environmental Ratings ................................................................................................................... 3 3 Regulatory Requirements ..................................................................................................................... 3 3.1 Agency Approval ............................................................................................................................ 3 4 Mechanical Outline ............................................................................................................................... 3 4.1 Base module .................................................................................................................................. 3 4.2 Current Transformer ...................................................................................................................... 3 5 Electrical ............................................................................................................................................... 4 5.1 Current Transformers (CT) ............................................................................................................. 4 5.2 Switches ........................................................................................................................................ 4 5.3 Terminals ....................................................................................................................................... 4 6 ZigBee Profile ....................................................................................................................................... 5 6.1 Supported Endpoints ..................................................................................................................... 5 6.2 Supported Clusters ........................................................................................................................ 6 7 Application Requirements .................................................................................................................... 8 7.1 Auto Join ....................................................................................................................................... 8 7.2 Power Factor Calculation (Optional) .............................................................................................. 8
2  1 General Features 1.1 System Metering type:   Minimum 2 channel ZigBee SEP 1.1x power meter  1.2 Metering Measurements Power measurement (W)   Power measurement reporting rate:  Minimum  2  seconds  for  one  channel.  Programmable  in  1 second step. Power measurement range:   45 – 48,000W/Channel  Power measurement (W)  With calibrated CT clamp on specified port Power measurement accuracy:    PF = 1  0.8 < PF < 1 Power < 100W  +/- 3W  +/- 4W Power > 100W  +/- 3%  +/- 4% Power measurement (W)  With non-calibrated CT clamp Power measurement accuracy:    PF = 1  0.8 < PF < 1 Power < 100W  +/- 5W  +/- 6W Power > 100W  +/- 5%  +/- 6% • Remark: Only Computime approved CTs can be used. • Remark: Calibration and testing only be carried with current lower than 100A. 1.3 Power Supply Power supply   90- 240 VAC 1.4 Memory Backup Memory backup  Non volatile memory backup.  All current summation attributes saved to non volatile memory to keep cumulative current consumption through power outages.   Data can be backup in every 60 seconds or longer Flash memory   Store firmware for Over The Air (OTA) upgrade  1.5 Indicator LED indicator   Network state indicator, minimum bi-color (red & green) 1.6 ZigBee ZigBee module   ZigBee Smart Energy 1.1x Capable  Frequency   2.4 - 2.48GHZ  Communication range   Up to 400m LOS in open site   2405-2480MHzZigBee SEP 1.1x power meter
3  2 Environmental Requirements 2.1 Environmental Ratings   Min.  Max.  Units Operating Temperature   -20   60   °C  Storage Temperature   -20   80  °C  Operating Humidity   5   95   %RH  • Indoor use only 3 Regulatory Requirements 3.1 Agency Approval FCC Regulation UL/CUL/ETL RoHS IEC 61000 4 Mechanical Outline  4.1 Base module Maximum dimensions: 6”x4.5”x2” 4.2 Current Transformer The maximum dimensions for the current transformer are show in the drawing below:
4 5 Electrical 5.1 Current Transformers (CT) The current transformers must be capable of measuring either consumption or generation. 5.2 Switches No  Switch  Function 1  PB  Push  button  for  manual  commissioning/decommissioning (see section 7.1 for auto join requirements) 5.3 Terminals AC L1  Line 1 input voltage AC Neutral  AC return CT Channel 1  Input socket 1 for CT clamp CT Channel 2  Input socket 2 for CT clamp CT Channel 3  Input socket 3 for CT clamp CT Channel 4  Input socket 4 for CT clamp
5 6 ZigBee Profile The device shall support ZigBee Smart Energy Profile 1.1 at a minimum. 6.1 Supported Endpoints The device shall provide one endpoint per channel. Each endpoint shall have a Simple Metering cluster and provide access to the other clusters (i.e. the Basic cluster for Endpoint 4 will actually point to the Basic cluster for Endpoint 1 to eliminate the need to duplicate and synchronize data). Any setting on Basic Cluster on any endpoint will be duplicated to all other endpoint End Point 1: Profile ID:   0x0109 Device Type/Device ID:   0x0501 Clusters:      End Point 2: Profile ID:   0x0109 Device Type/Device ID:   0x0501 Clusters:      End Point 3: Profile ID:   0x0109 Device Type/Device ID:   0x0501 Clusters:      Server  Client Basic Cluster(0x0000)  Time Cluster(0x000A) Simple Meter Cluster(0x0702) OTA Cluster(0x0019) Identify Cluster (0x0003)  Key Establishment Cluster(0x0800) Key Establishment Cluster(0x0800) Server  Client Basic Cluster(0x0000) Simple Meter Cluster(0x0702) Server  Client Basic Cluster(0x0000)
6 End Point 4: Profile ID:   0x0109 Device Type/Device ID:   0x0501 Clusters:      6.2 Supported Clusters Server side  Client side Common Basic Identify Simple Meter Cluster(0x0702) Server  Client Basic Cluster(0x0000) Simple Meter Cluster(0x0702)
7 Key Establishment Time OTA SE Simple Metering Key Establishment Each Simple Metering Cluster shall contain the following attributes: All other clusters shall adhere to the ZigBee Smart Energy Specification.
8 7 Application Requirements 7.1 Auto Join The device shall power up initially in a state that beacons the ZigBee Smart Energy network at a minimum of once per minute to facilitate joining the HAN. This state shall also become active as soon as the device leaves a HAN. The device shall remain in this state until it joins a HAN. 7.2    Power Factor Calculation (Optional) The device shall be capable of calculating the power factor and reporting this measurement upon request. Disclaimer Schneider Electric reserves the right to make changes without further notice to any products herein to improve reliability, function, or design. Schneider Electric does not assume any liability arising out of the application or use of any product described herein; neither does it convey any license under its patent rights, not the rights of others. FCC StatementThis equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:-- Reorient or relocate the receiving antenna.  -- Increase the separation between the equipment and receiver.   -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  -- Consult the dealer or an experienced radio/TV technician for help.This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.The distance between user and products should be no less than 20cm