Seba Dynatronic Mess und Ortungstechnik LOGRIP Radio Interface For Communication With LOG N-3 User Manual

Seba Dynatronic Mess- und Ortungstechnik GmbH Radio Interface For Communication With LOG N-3

User manual

Download: Seba Dynatronic Mess und Ortungstechnik LOGRIP Radio Interface For Communication With LOG N-3 User Manual
Mirror Download [FCC.gov]Seba Dynatronic Mess und Ortungstechnik LOGRIP Radio Interface For Communication With LOG N-3 User Manual
Document ID3596959
Application IDBwfmGqzsxZIQeN2QaLejrg==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize145.16kB (1814462 bits)
Date Submitted2017-10-10 00:00:00
Date Available2017-10-11 00:00:00
Creation Date2017-08-31 11:37:25
Producing SoftwareGPL Ghostscript 9.14
Document Lastmod2017-08-31 11:37:25
Document TitleUser manual
Document CreatorPDF24 Creator

Consultation with SebaKMT
User Manual
GSM Transmitter
Sebalog GT-3-S
Mess- und Ortungstechnik
Measuring and Locating Technologies
Elektrizitätsnetze
Power Networks
Kommunikationsnetze
Communication Networks
Rohrleitungsnetze
Water Networks
Abwassernetze
Sewer Systems
Leitungsortung
Line Locating
Issue:
Article number:
01 (04/2017) - EN
85837
Consultation with SebaKMT
Consultation with SebaKMT
Consultation with SebaKMT
The present system manual has been designed as an operating guide and for
reference. It is meant to answer your questions and solve your problems in as fast and
easy a way as possible. Please start with referring to this manual should any trouble
occur.
In doing so, make use of the table of contents and read the relevant paragraph with
great attention. Furthermore, check all terminals and connections of the instruments
involved.
Should any question remain unanswered or should you need the help of an authorized
service station, please contact:
Seba Dynatronic
Mess- und Ortungstechnik GmbH
Hagenuk KMT
Kabelmesstechnik GmbH
Dr.-Herbert-Iann-Str. 6
D - 96148 Baunach
Phone: +49 / 9544 / 68 – 0
Fax: +49 / 9544 / 22 73
Röderaue 41
D - 01471 Radeburg / Dresden
Phone: +49 / 35208 / 84 – 0
Fax: +49 / 35208 / 84 249
E-Mail: sales@sebakmt.com
http://www.sebakmt.com
 SebaKMT
All rights reserved. No part of this handbook may be copied by photographic or other means unless SebaKMT
have before-hand declared their consent in writing. The content of this handbook is subject to change without
notice. SebaKMT cannot be made liable for technical or printing errors or shortcomings of this handbook.
SebaKMT also disclaims all responsibility for damage resulting directly or indirectly from the delivery, supply,
or use of this matter.
Terms of Warranty
Terms of Warranty
SebaKMT accept responsibility for a claim under warranty brought forward by a
customer for a product sold by SebaKMT under the terms stated below.
SebaKMT warrant that at the time of delivery SebaKMT products are free from
manufacturing or material defects which might considerably reduce their value or
usability. This warranty does not apply to faults in the software supplied. During the
period of warranty, SebaKMT agree to repair faulty parts or replace them with new parts
or parts as new (with the same usability and life as new parts) according to their choice.
This warranty does not cover wear parts, lamps, fuses, batteries and accumulators.
SebaKMT reject all further claims under warranty, in particular those from consequential
damage. Each component and product replaced in accordance with this warranty
becomes the property of SebaKMT.
All warranty claims versus SebaKMT are hereby limited to a period of 12 months from
the date of delivery. Each component supplied by SebaKMT within the context of
warranty will also be covered by this warranty for the remaining period of time but for 90
days at least.
Each measure to remedy a claim under warranty shall exclusively be carried out by
SebaKMT or an authorized service station.
This warranty does not apply to any fault or damage caused by exposing a product to
conditions not in accordance with this specification, by storing, transporting, or using it
improperly, or having it serviced or installed by a workshop not authorized by SebaKMT.
All responsibility is disclaimed for damage due to wear, will of God, or connection to
foreign components.
For damage resulting from a violation of their duty to repair or re-supply items,
SebaKMT can be made liable only in case of severe negligence or intention. Any liability
for slight negligence is disclaimed.
Since some states do not allow the exclusion or limitation of an implied warranty or of
consequential damage, the limitations of liability described above perhaps may not
apply to you.
Terms of Warranty
Contents
Consultation with SebaKMT ...........................................................................................3
Terms of Warranty ...........................................................................................................4
Safety Instructions ...........................................................................................7
1.1
General Safety Instructions and Warnings.........................................................7
1.2
General Notes ....................................................................................................7
Technical description ......................................................................................9
2.1
Device design .....................................................................................................9
2.2
Function ............................................................................................................10
2.3
2.3.1
2.3.2
Communication ................................................................................................10
LOG RI / LOG RI+ wireless interface for the computer....................................11
Reader-3 as a wireless interface for the computer ..........................................11
2.4
Power supply ....................................................................................................12
2.5
Technical data ..................................................................................................13
2.6
Included in delivery...........................................................................................13
Inserting the SIM card / changing the battery .............................................15
Switching the GT-3-S on/off ..........................................................................19
Preparatory work in the office ......................................................................21
5.1
Mobile network, FTP server, e-mail account, etc. ............................................21
5.2
Inserting a SIM card in the GT-3-S ..................................................................21
5.3
Preparing loggers .............................................................................................21
5.4
Connecting the wireless interface to the PC / laptop .......................................21
5.5
Saving access data for FTP server and e-mail account in the SebaDataView-3
software ............................................................................................................22
5.6
5.6.1
5.6.2
5.6.3
Registering devices in the SebaDataView-3 software .....................................23
Introduction .......................................................................................................23
Selecting a zone or creating a new one ...........................................................23
Creating a group and adding a GT-3-S ............................................................24
5.7
5.7.1
5.7.2
Programming the GT-3-S .................................................................................25
Basic procedure ...............................................................................................25
Explanations for the GSM input window ..........................................................26
5.8
Performing a GSM test .....................................................................................29
GT-3-S activities performed at the installation site ....................................31
6.1
Introduction .......................................................................................................31
6.2
6.2.1
6.2.2
Connecting the aerial and switching on GT-3-S ..............................................31
Connecting the GSM/GPS aerial to the GT-3-S ..............................................31
Switching on GT-3-S ........................................................................................31
6.3
Adding loggers to the GT-3-S group ................................................................32
6.4
Installing devices in the shaft ...........................................................................33
Terms of Warranty
6.4.1
6.4.2
Installing loggers ..............................................................................................33
Installing GT-3-S ..............................................................................................33
6.5
Programming noise loggers (Log N-3) .............................................................34
6.6
Programming pressure loggers (Log P-3 / P-3 mini) .......................................35
6.7
Sending the configuration to the GT-3-S..........................................................36
6.8
Synchronising the GT-3-S with GPS ................................................................37
6.9
“Linking” GT-3-S to loggers ..............................................................................37
6.10
Performing the GSM test and closing the shaft ...............................................38
Safety Instructions
Safety Instructions
1.1
General Safety Instructions and Warnings
Do not drop the device / the system’s components or subject it / them to
strong impacts or mechanical shocks.
• The limits described under Technical Data may not be exceeded.
• The device / system must be in a technically perfect condition for
measurement.
•
1.2
General Notes
Safety precautions This manual contains basic instructions for the commissioning and operation of the
device / system. For this reason, it is important to ensure that the manual is always
available to the authorised and trained operator. He needs to read the manual
thoroughly. The manufacturer is not liable for damage to material or humans due to nonobservance of the instructions and safety advices provided by this manual.
Locally applying regulations have to be observed!
Labelling of safety The following signal words and symbols are used in this manual and on the product
instructions itself:
Signal word /
symbol
Description
CAUTION
Indicates a potential hazard which may result in moderate or minor
injury if not avoided.
NOTICE
Indicates a potential hazard which may result in material damage if
not avoided.
Serves to highlight warnings and safety instructions.
As a warning label on the product it is used to draw attention to
potential hazards which have to be avoided by reading the manual.
Serves to highlight important information and useful tips on the
operation of the device/system. Failure to observe may lead to
unusable measurement results.
Check contents Check the contents of the package for completeness and visible damage right after
receipt. In the case of visible damage, the device must under no circumstances be taken
into operation. If something is missing or damaged, please contact your local sales
representative.
Working with products It is important to observe the generally applicable regulations of the country in which the
from SebaKMT device will be operated, as well as the current national accident prevention regulations
and internal company directives (work, operating and safety regulations).
Use genuine accessories to ensure system safety and reliable operation. The use of
other parts is not permitted and invalidates the warranty.
Repair and Repair and maintenance work has to be carried out by SebaKMT or authorised service
maintenance partners using original spare parts only. SebaKMT recommends having the system
tested and maintained at a SebaKMT service centre once a year.
SebaKMT also offers its customers on-site service. Please contact your service centre if
needed.
Safety Instructions
Special transportation The lithium batteries of the device are dangerous goods. The transport of the batteries
requirements itselves and of devices which contain such batteries is subject to regulations based on
the UN Model Regulations “Transport of Dangerous Goods” (ST/SG/AC.10-1).
Please inform yourself about the transportation requirements and follow them when
shipping the device.
Electromagnetic This device is designed for industrial use. When used at home it could cause
radiation interference to other equipment, such as the radio or television.
The interference level from the line complies with the limit curve B (living area), the
radiation level complies with the limit curve A (industrial area) according to EN 55011.
Given that living areas are sufficiently far away from the planned area of operation
(industrial area), equipment in living areas will not be impaired.
1.3
FCC label / IC label
GT-3-S This device/system complies with Part 15 of the FCC Rules and with Industry Canada licenseexempt RSS standard(s). Operation is subject to the following two conditions: (1) this
device/system may not cause harmful interference, and (2) this device/system must accept any
interference received, including interference that may cause undesired operation.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio
exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne
doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
Changes or modifications not expressly approved by the party responsible for compliance could
void the user's authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of
the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
LOG RI+ User Information acc. to FCC15.21:
Changes or modifications not expressly approved by the party responsible for compliance
could void the user's authority to operate the equipment.
Part 15 Statement acc. to FCC 15.19/RSS Gen Issue 3 Sect. 7.1.3:
This device complies with Part 15 of the FCC Rules and with Industry Canada license-exempt
RSS standard(s). Operation is subject to the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
This equipment should be installed and operated with a minimum distance of 20
centimeters between the radiator and your body.
Technical description
Technical description
2.1
Device design
External features The GT-3-S has the following controls and external features:
Element Description
Cover plug with suspension ring
Top cover ring
Type plate with the device identification number (ID)
Bottom cover ring
Protective bracket
GPS socket for aerial connection
GSM socket for aerial connection
On/Off contact field (magnetic switch) and status LED
1x red, 3x green
Flashes blue
Remains lit in blue
Yellow, then red
...
...
...
...
When switched on
Device is switched on and ready for transmission
Data is being transmitted
When being switched off
Technical description
Cover rings There is one “cover ring” at the top and bottom end of the GT-3-S respectively. These
rings are screwed onto the housing by means of inside threads. They are used to
secure the cover or the base of the device, and to seal the device tightly.
The top cover ring
may be opened to access the SIM card slot and the battery.
NOTE
The bottom cover ring
must NEVER be opened.
Otherwise, electronic components in the device may be damaged.
If the cover ring is unscrewed anyway, the yellow guarantee sticker will be
damaged. In this case, the device guarantee is voided.
2.2
Function
The GT-3-S device is a compact, waterproof GSM module with its own source of
energy. In addition, the device is equipped with an internal GPS receiver.
• The GT-3-S is used as an interface to the mobile network for: LOG N-3 noise level
loggers
• LOG P-3 pressure loggers
The GT-3-S enables the following functions for the loggers to which it is connected:
• Regular uploads of measured data to an FTP server (1x daily)
• Regular transmission of measured data by e-mail/SMS
• Sending alarm messages by e-mail/SMS when thresholds are exceeded
• Identifying and saving the GPS position
Up to three loggers can be connected to one GT-3-S at the same time.
2.3
Communication
The GT-3-S features an integrated GSM/GPRS modem, and an integrated wireless
module for short-range radio.
Short-range radio is used for:
• Communication between GT-3-S and the loggers connected
• Communication between GT-3-S and a PC/laptop
(a wireless interface must be connected to the computer – see the following
section)
The mobile network is used for:
• Transfer of the data measured by the logger from the GT-3-S to the FTP server
• Sending messages by e-mail/SMS
10
Technical description
2.3.1
LOG RI / LOG RI+ wireless interface for the computer
LOG RI The “LOG RI” device is the compact, standard wireless interface for devices in the
Sebalog series.
LOG RI+ The “LOG RI+” wireless interface is available as an accessory from SebaKMT.
In contrast to the LOG RI, the device has a more powerful wireless module that has a
greater wireless range.
Log RI
Log RI+
Handling The LOG RI / LOG RI+ is easily connected to the computer using a USB port. This turns
it on automatically. The device is automatically recognised by the computer and is
immediately ready to set up a radio connection. No other settings need to be made.
Status LED The LOG RI / LOG RI+ device is equipped with an LED as a status indicator:
Flashes 1x red, 1x green
• Lights up in blue
• Lights up in red
•
When switched on
During radio operation
Malfunction
Update We recommend always operating the device with the latest firmware. Information on
updating device firmware can be found in the respective operating manuals for the noise
or pressure loggers.
2.3.2
Reader-3 as a wireless interface for the computer
The “Reader-3” reading device from SebaKMT can be used as a wireless interface.
Connect the device to the computer by means of the corresponding “docking station”
and switch it on. The device automatically switches to “USB mode”. It is automatically
recognised by the computer and is immediately ready to set up a radio connection. No
other settings need to be made. You can find more information about this in the
Reader-3 operating manual.
11
Technical description
2.4
Power supply
The GT-3-S is supplied with energy by an internal lithium battery.
The battery can be inserted and replaced by the user.
Battery criteria The battery used must meet the following criteria:
Parameter
Value
Type
Size
Quantity
Rated voltage
Capacitance
Continual discharge current
Lithium battery
D cell
3.6 V
min. 13 h
min. 3 A
Querying the If you wish to obtain information about the battery status of a GT-3-S, you should read
battery status out the current device configuration.
The GT-3-S must be switched on and be within wireless range of the computer.
Proceed as follows.
Step Description
Mark the GT-3-S concerned in the directory tree of the SDV-3 software.
Click on Program in the menu bar.
Click on Read settings at the bottom of the window.
Result: The current configuration is read out and displayed by the device.
Click on Status at the bottom of the window.
Result: A window with information about the current status of the device opens.
One of the following items of information can also be found there:
• Battery full
• Battery OK
• Battery critical
12
Technical description
2.5
Technical data
The GT-3-S is distinguished by the following technical parameters:
2.6
Parameter
Value
Display
Status LED
Communication
Short-range radio
913.02 MHz (US)
868 / 916 MHz (depending on country)
Mobile network (913.02 MHz device):
Dual band UMTS/HSDPA 850/1900 MHz
Quad band GSM/GPRS/EDGE 850/900/1800/1900 MHz
Mobile network (868 / 916 MHz device):
Dual band UMTS/HSDPA 900/2100 MHz
Quad band GSM/GPRS/EDGE 850/900/1800/1900 MHz
Power supply
3.6 V lithium battery
Operating
temperature
-20 to +60 °C
Storage temperature
-20 to +70 °C
Dimensions
190 x 69 mm Ø
Weight
approx. 0.5 kg (without battery)
Protection class
IP68
Included in delivery
Standard accessories The standard delivery includes the following components:
Part
Description
LOG GT-3-S
GSM transmitter
LOG GT-3-S-868
LOG GT-3-S-913
LOG GT-3-S-916
Serial no.
1009289
1008710
1009291
LOG GT-3-S-A
GPS/GSM aerial
2009013
VK129
Connection cable for LOG GT-3-S-A (2 included)
90021036
Switch-on magnet
Optional accessories In addition to the standard delivery, additional accessory parts are available:
Part
Description
Serial no.
LSH-20
Spare battery
820007318
Coil spring for aerial (USA)
90021150
GPS receiver for laptop
820013945
13
Technical description
14
Inserting the SIM card / changing the battery
Inserting the SIM card / changing the battery
The following is a description of the steps to carry out in order to
• insert a SIM card in the device
• replace a battery.
The device must be opened to access the battery holder and the SIM card slot.
NOTE
The device contains sensitive semi-conductor components.
Always proceed carefully in order not to damage any of the components.
Do not use force.
Opening the housing In order to open the housing, proceed as follows:
Step Description
The device must be switched off (status LED
Hold the GT-3-S in one hand.
Hold the device around the middle of the housing, and not by the bottom cover
ring.
Do NOT hold it
here!
Open the top cover ring
stays off).
Hold it here!
and screw it off the housing.
NOTE
The bottom cover ring
may NOT be unscrewed.
Electronic components inside the device could be damaged.
When unscrewed, the guarantee sticker on the device will break
and all guarantee claims are immediately voided.
(continued on next page)
15
Inserting the SIM card / changing the battery
Step Description
Carefully pull the cover plug out of the housing.
Result: You can now access the battery holder.
Placing the GT-3-S on a table or another level surface is recommended
at this point. The type plate should face upwards.
Hold the housing tight in one hand.
Use your other hand to carefully pull the battery holder out of the housing, but
only as far as the ribbon cable allows.
Caution: Do not pull with too much force, or with a sudden motion. The ribbon
cable must not be torn or damaged in any other way.
The ribbon cable may be disconnected from the battery holder when
necessary, and be reconnected later on (also see the description that
follows, “Changing the battery”). This is generally unnecessary when
replacing the SIM card, because the battery holder does not need to
be pulled completely out of the housing to do so. The ribbon cable has
a sufficient length for this activity.
Inserting the SIM card The slot for the SIM card is on the bottom of the battery holder.
Push the SIM card into the slot until you can feel it lock into place.
To remove the card, start by pushing the card slightly into the slot to release it from the
holder. The card is then pushed out of the slot by the spring mechanism, and can be
removed.
Proceed carefully! Otherwise the SIM card may be ejected suddenly, and may be lost.
Changing the battery In order to change the battery, proceed as follows:
Step Description
Unplug the ribbon cable connector from the battery holder.
Remove the battery holder from the housing completely.
Replace the old battery with a new one.
16
Inserting the SIM card / changing the battery
Step Description
When inserting the battery, make sure the polarity is correct. There are plus and
minus symbols on the battery holder indicating this.
Reconnect the ribbon cable to the battery holder.
Closing the housing In order to close the housing again, proceed as follows.
again
Step Description
Carefully push the battery holder back into the housing.
Then push the ribbon cable into the housing.
Note:
• There is exactly one correct position in which the complete battery holder is in
the housing, fits properly and can no longer be turned. Find this position.
• Do not bend or pinch the ribbon cable!
Close the housing again using the cover plug.
Note:
• The rubber sealing ring on the plug and the contact surface must be free of
dirt.
• Once the battery holder has been correctly fitted in the housing, the cover
plug is easy to insert and will not touch the battery holder. Should the battery
holder prevent the plug from being inserted, then the battery holder is still not
in the right position.
• Do not bend or pinch the ribbon cable!
Screw the cover ring back onto the housing.
Note:
• The thread on the cover ring and housing must be free of dirt.
• Carefully tighten the ring by hand. Do not overtighten!
Resetting the battery When you have changed battery, then you will need to reset the internal “battery
counter counter” of the GT-3-S to zero.
The following prerequisites must be met:
• A wireless interface (e.g. LOG RI) must be connected to the computer.
• The GT-3-S must have been added in the SDV-3 software.
• The GT-3-S must be switched on and be within wireless range of the computer.
Proceed as follows.
Step Description
Mark the GT-3-S concerned in the directory tree of the SDV-3.
Click on Program in the menu bar.
Click on Read settings at the bottom of the window.
Result: The current configuration is read out and displayed by the device.
Click on Status at the bottom of the window.
Result: A new window opens.
Click on Reset battery counter in the window.
17
Inserting the SIM card / changing the battery
18
Switching the GT-3-S on/off
Switching the GT-3-S on/off
The GT-3-S features an internal magnet switch for switching it on and off.
Move the supplied magnet over the On/Off contact field
. The status LED lights up in
red first; after the magnet is removed, it flashes in green three times. An LED regularly
flashing in blue then indicates that the device is switched on and ready for data
reception.
To switch off the logger, hold the magnet on the On/Off contact field for a few seconds.
The LED first lights up yellow. As soon as it lights up red, you can remove the magnet.
The device then switches off and the LED goes out.
19
Switching the GT-3-S on/off
20
Preparatory work in the office
Preparatory work in the office
5.1
Mobile network, FTP server, e-mail account, etc.
GSM / GPRS / UMTS For data transfer using the mobile network, a contract with a mobile service provider
must be concluded. You will require a SIM card that is enabled for data traffic using
GPRS / UMTS.
FTP server You will require free memory on an FTP server to be able to upload measured data to
it. You can use your company’s own server environment for this purpose or conclude a
licence agreement with a commercial provider on the Internet.
You can also rent storage space on an FTP server provided by SebaKMT. Please
contact your SebaKMT sales partner to do so.
Under certain conditions, it is also possible to access the company’s own “demo server”
from SebaKMT.
Your log-in requires read and write rights for the FTP server concerned.
The FTP server must be configured so that the GT-3-S appears in the
root directory of the FTP user after logging in.
After logging in, the GT-3-S runs the command “CWD /” and searches for the
sub-directory corresponding to the device from there.
The corresponding root directories must have been created in this root directory
for the respective device types.
E-mails If you wish to receive alarm messages or status messages per e-mail, you will require
an e-mail account that functions as the sender. Should your company’s own mail
server be unsuitable for this (e.g. due to a firewall, etc.), then you can sign a usage
agreement with a commercial provider.
Under certain conditions, it is also possible to access the company’s own “demo
account” from SebaKMT.
5.2
Inserting a SIM card in the GT-3-S
A SIM card must be inserted in every GT-3-S that is used for measurements.
You received one from your mobile operator when you signed a mobile contract.
The card slot for the SIM card is inside the device, at the bottom of the battery holder.
Exact information about the steps required can be found in the section “Inserting a SIM
card / Changing the battery”.
5.3
Preparing loggers
Have all loggers you wish to use for measurements ready.
The loggers must be switched off.
5.4
Connecting the wireless interface to the PC / laptop
To communicate with the GT-3-S, a wireless interface (e.g. LOG RI) must be connected
to the computer.
21
Preparatory work in the office
5.5
Saving access data for FTP server and e-mail account in the
SebaDataView-3 software
You must now save the access data for the FTP server used, along with the access
data for the e-mail account you are using, in the SebaDataView-3 software
configuration.
This step is necessary to be able to download measured data from the FTP server and
import it into the SDV-3 software at a later stage. Furthermore, the access data saved
can then be entered in the respective input mask by “clicking the mouse” when
programming the GT-3-S devices. This makes programming easier and considerably
faster.
Procedure Proceed as follows:
Step Description
Open the SebaDataView-3 software.
Click on the drop symbol
at the upper left of the window.
Click on Settings in the context menu that opens.
Open the FTP tab in the configuration.
Result: The following entry screen then appears in the window:
The FTP settings segment contains input fields for entering the access data for
your FTP server. You can ask your company's system administrator or the server
operator for this data, or look it up in your FTP usage agreement.
The E-mail settings segment contains input fields for entering the access data for
the sender e-mail account to be used when messages are to be sent by e-mail.
Ask your company's system administrator or the e-mail account provider for this
data. You can enter any name or similar designation in the Sender name field,
and this will be used to identify the device as the sender of the message.
Click the respective Use own settings checkbox.
Enter the access data in the input boxes.
Click on OK to confirm the details and to close the window.
Result: The access data are now on file in the software. When programming the
devices, a checkbox is shown for each of the steps in the input area, and this can
be used to add the access data saved.
22
Preparatory work in the office
5.6
Registering devices in the SebaDataView-3 software
5.6.1
Introduction
All GT-3-S and all loggers that are to be used for the upcoming measurement must have
been registered in the SebaDataView-3 software.
You can register the devices in the office, or do this directly on site.
Important information Observe the following points:
•
All devices in the network (i.e. all GT-3-S used and all loggers) must be combined
to form a shared zone.
• A specific group must be created for every GT-3-S that is used for the
measurement. The loggers that are to be connected to the GT-3-S concerned are
added to this group.
•
A maximum of 3 loggers can be added to a GT-3-S group.
Example:
Shared zone
for the GT-3-S network
Group “Group I”
is assigned transmitter “81” and
the loggers that are to be
connected to it
Group “Group II”
is assigned transmitter “82” and
the loggers that are to be
connected to it
5.6.2
Selecting a zone or creating a new one
Select the zone to which the GT-3-S and the loggers concerned should be added in the
directly tree, or create a new zone.
To create a new zone, proceed as follows:
Step Description
Mark the folder in which the new zone should be created.
Open the Directory tab in the menu bar.
(continued on next page)
23
Preparatory work in the office
Step Description
Click New in the Zone segment.
In the window which opens, give the new zone a name and add a comment.
Confirm the inputs using OK.
Result: The new zone has now been created in the database and will appear in
the directory tree.
5.6.3
Creating a group and adding a GT-3-S
Creating a new group Create a new group in the directory tree.
Step Description
Mark the zone under which the new group should be created.
Click New in the Group segment.
In the window which opens, give the new group a name and add a comment.
Confirm the inputs using OK.
Result: The new group has now been created in the database, and appears in
the directory tree.
Adding GT-3-S Add a GT-3-S to the new group.
to the group
Step Description
Mark the newly created group in the directory tree.
Open the LogGT3S tab in the menu bar.
Click New in the Administration segment.
Register the required GT-3-S.
Manually
Automatically
Deactivate the Automatic detection
checkbox and enter the identification
number (ID) of the device.
Activate the Automatic detection
checkbox, then switch on the device.
Result: The identification number (ID)
of the device is recognised and
displayed.
Enter a comment about the device as a text input, and confirm all inputs using
OK.
Result: The GT-3-S is now registered and appears in the directory tree.
Click on Close to complete the process. (The GT-3-S is “connected” to the
loggers later on at the site of use.)
24
Preparatory work in the office
Please remember: Only one GT-3-S can be registered per group. As soon as you
wish to add an additional GT-3-S to the zone, you must start by creating a new
group in this zone.
The first GT-3-S in the zone should have already received a complete
configuration before additional GT-3-S devices are added to the zone. All new
GT-3-S will automatically copy the configuration data of the first GT-3-S in the
zone. This considerably reduces the work required to program these devices.
5.7
Programming the GT-3-S
5.7.1
Basic procedure
The GT-3-S must be programmed before measurements are taken. This involves
allocating all GSM configuration data to the device.
Requirements The GT-3-S concerned must be switched on and be within wireless range of the
computer.
Procedure Proceed as follows:
Step Description
Mark the GT-3-S concerned in the directory tree of the SDV-3.
Click on Program in the menu bar.
(If necessary, open the LogGT3S tab beforehand.)
Result: The window for input of the configuration data opens.
Enter all data required for the mobile connection. (You will find more detailed
information in the next section).
Enter the weekdays, and from when until when on each of these days, the
GT-3-S should be responsive to outside transmissions by short-range radio in the
Radio settings segment.
Click on Program at the bottom of the window.
Result: The GSM settings are sent to the GT-3-S by radio.
After completing the process, a dialogue window appears. You will be asked
whether you would like to continue with the next step directly.
Click on No in the dialogue window displayed.
25
Preparatory work in the office
5.7.2
Explanations for the GSM input window
The figure shows the input mask for GSM configuration data. All parameters necessary
for the mobile connection from / to the GT-3-S to function must be entered in it. (The
data required can be found in your mobile phone contract, or ask your mobile operator
for them.)
GSM parameters You will find explanations for the individual items in the configuration window in the
table.
Segment
Parameter
SIM card settings
Enter the phone number and the PIN code for the SIM card being
used in the GT-3-S.
Internet settings
Specify the Internet access data for your mobile operator here
(server address, user name, password, etc.).
If your mobile operator is included in the drop-down list Provider,
select it and the required data will be entered automatically.
FTP settings
The access data for the FTP server to which the measured data
are to be sent (server address, port, user name, password) must
be entered here. The data will be given to you when you sign the
FTP usage agreement, or you can ask the operator of the FTP
server for them.
If you have already entered the access data for your server in the
software configuration and you wish to use this server, mark the
Use own server checkbox. The data in the configuration are then
accepted and the data appears in the input boxes.
If you wish to use the SebaKMT demo server, mark the
Seba Demo Mode checkbox. The access data are then entered
automatically.
(Please note that this server may be used temporarily and for
demonstration purposes only!)
26
Preparatory work in the office
Segment
Parameter
Use the checkboxes to specify when the measured data should
be uploaded:
Every selected GSM day P Data will be uploaded every day
(more exactly: on every
“GSM day”).
In case of leak P Data will only be uploaded if the leak
threshold of a logger was exceeded during
the last measurement.
If no measured data are to be uploaded, deactivate both
checkboxes.
E-mail settings
Do you wish to receive alarm messages by e-mail in the event of
suspected leaks or when a pressure surge occurs?
Then enter the access data for the e-mail account used to send
messages here (domain, server address, port, user name,
password). The data will be assigned to you by the operator of the
mail account, or by your system administrator.
If you have already entered the access data for your server in the
software configuration and you wish to use this server, mark the
Use own server checkbox. The data in the configuration are then
accepted and the data appears in the input boxes.
If you wish to use the SebaKMT demo account, mark the
Seba Demo Mode checkbox. The access data are then entered
automatically.
(Please note that this account may be used temporarily and for
demonstration purposes only!)
E-mail destination
Do you wish to receive alarm messages and overviews of
measured data by e-mail?
Then enter up to two recipient addresses here.
Use the checkboxes to decide whether you only wish to receive
e-mails in the event of an alarm, or receive e-mails daily (more
exactly: on every “GSM day”).
If you do not wish to receive e-mails at all, deactivate both
checkboxes.
SMS destination
Do you wish to receive alarm messages and overviews of
measured data by SMS?
Then enter up to three recipient phone numbers here.
Do not use spaces or special characters.
Use the checkboxes to decide whether you only wish to receive
SMS in the event of an alarm, or receive SMS daily (more exactly:
on every “GSM day”).
If you do not wish to receive SMS at all, deactivate both
checkboxes.
“GSM days” Segment
GSM transmission
Parameter
Define the days of the week on which the GSM modem in the
GT-3-S is to be active (so-called “GSM days”).
Uploading or sending measured data or notifications is only
possible on these days.
27
Preparatory work in the office
“Radio transmission Segment
time”
Radio settings
Audio data Segment
Miscellaneous
settings
Parameter
Define when the GT-3-S and other devices connected should be
responsive to outside transmissions by short-range radio.
Use the checkboxes to select the required days of the week (socalled “Radio transmission days”). Use the two drop-down menus
to select the transmission period for each transmission day.
Explanation: Devices that should be responsive to outside
transmissions by short-range radio around the clock consume
much more energy. To conserve the energy in the batteries of the
GT-3-S and the loggers connected, limiting the availability of the
devices to a defined daily period (so-called “Radio transmission
time”) is recommended.
The transmission time set does not affect transmission activities
between the devices connected.
Parameter
Request audio on same day checkbox
This checkbox is only relevant for work using N-3 noise loggers.
When this checkbox has been activated, audio requests are
processed on the same day, meaning that the audio files on the
logger are available for downloading on the same day.
Prerequisite is that the audio request is sent one hour after the
‘Radio transmission time’ begins at the latest.
If the request is sent later, then the audio files will only be
available following the next regular data upload.
When this checkbox is deactivated, then audio requests will not
be processed on the same day. The audio files on the logger will
only be available following the next regular data upload.
Note: When this checkbox is activated, this results in much more
energy being consumed by both the GT-3-S and the loggers
connected.
Auto audio request checkbox
This checkbox is only relevant for work using N-3 noise loggers.
When this checkbox is activated, audio files from the
measurement day are also automatically uploaded in the event of
an alarm (i.e. when a threshold is exceeded) without the user
having to request this. The audio files are then uploaded to the
FTP server by the GT-3-S on the same day.
Note:
• When this checkbox is activated, this results in much more
energy being consumed by both the GT-3-S and the loggers
connected.
• From the third consecutive measurement days with an alarm
onwards, no audio files will be uploaded to save energy.
28
Preparatory work in the office
GPS function Segment
Miscellaneous
settings
Theft alarm Segment
Miscellaneous
settings
5.8
Parameters
Sync to GPS checkbox
This checkbox allows you to define whether the GPS module for
the GT-3-S is activated or deactivated for the upcoming
measurement.
When the checkbox is activated, the internal clock of the GT-3-S
and the loggers connected can be synchronised with GPS time
and the GPS position of the GT-3-S can be identified.
Note: This checkbox must be activated when the noise data
recorded are to be correlated later on.
Parameters
Theft protection checkbox
This checkbox only functions when the “Sync to GPS” checkbox is
activated at the same time.
When this checkbox is activated, the GPS position of the
GT-3-S will be compared with the GPS data of the installation
location once a day. If the positions are different, an alarm
message is sent to the user by SMS / e-mail.
Performing a GSM test
To avoid complications on site, you should perform an initial GSM test with every
GT-3-S to be used for measurements while still in the office. This involves checking
whether the device can connect to the mobile network properly.
Requirements The following prerequisites must be met:
• A wireless interface (e.g. LOG RI) must be connected to the computer.
• The GT-3-S concerned must have been created in the SDV-3 software.
• The GT-3-S concerned must have been set up for GSM operation. (SIM card
inserted, device programmed)
• The GT-3-S concerned must be switched on and be within wireless range of the
computer.
Procedure To perform a GSM test with the aid of the computer, proceed as follows:
Step Description
Mark the GT-3-S concerned in the directory tree of the SDV-3.
Click on Check GSM in the menu bar.
(If necessary, open the LogGT3S tab beforehand.)
Result: A new window opens.
Click on Check GSM in the window.
Result: The GSM test starts. The GT-3-S uploads a test file called “ftp-test.csv” to
the FTP server.
(continued on next page)
29
Preparatory work in the office
Step Description
The GT-3-S also sends a test e-mail or a test SMS to all recipients specified. The
individual test steps are listed in the window on the screen. Successfully
completed steps are marked with OK. An error message will appear if this is not
the case.
Possible causes If the GSM test fails, check the following items again:
of faults
• Has a SIM card been inserted in the GT-3-S?
• Does the SIM card support data transmission?
(Check the mobile contract or ask the mobile operator)
• Are GSM and data transmission activated on the SIM card?
(Ask the mobile operator)
• Are the GSM settings that have been made suitable for the SIM card being used?
• Are the GSM settings that have been made suitable for the GT-3-S being used?
• Were the GSM settings sent to the GT-3-S?
• Is the battery charge of the GT-3-S still sufficient?
30
GT-3-S activities performed at the installation site
GT-3-S activities performed at the installation site
6.1
Introduction
After performing the set-up tasks in the office, all other steps must be performed directly
at the usage site using a laptop.
The following prerequisites must be met:
• Laptop with SebaDataView-3 software
• A wireless interface (e.g. LOG RI) must be connected to the laptop.
• The loggers must be switched off.
• All GT-3-S devices must be equipped with a SIM card.
• All GT-3-S devices should be switched off.
• One GPS/GSM aerial and two ‘VK129’ connection cables for each individual
GT-3-S need to be kept ready.
Note: The GT-3-S and the loggers connected to it must be installed in one and the
same shaft. Otherwise, the radio connection between the devices might not
function properly.
You will find explanations of the individual worksteps in the following sections.
6.2
Connecting the aerial and switching on GT-3-S
6.2.1
Connecting the GSM/GPS aerial to the GT-3-S
Introduction The GSM module and the GPS module for the GT-3-S are integrated in the device.
The combined GSM/GPS aerial is not, however, integrated, and must be connected to
the GT-3-S using the connection cables.
The long connection cables allows the aerial to be positioned high up in the shaft, or
outside the shaft, while the GT-3-S remains inside the shaft.
Use of the GT-3-S is not possible without an aerial connected.
Requirements The following is required:
• 1x external GSM/GPS aerial for GT-3-S (included in delivery)
• 2x ‘VK129’ connection cables (included in delivery)
Procedure Proceed as follows:
Step Description
6.2.2
Connect one of the two cables to the GSM socket of the aerial.
Tighten the nut on the screw connection using your fingers. Do not use tools.
Connect the other end of the cable to the GSM socket on the GT-3-S.
Connect the second cable to the GPS socket of the aerial.
Connect the other end of the cable to the GPS socket on the GT-3-S.
Switching on GT-3-S
Switch on the GT-3-S, or ensure that it is still switched on. The status LED flashes
regularly in blue when the device is switched on.
31
GT-3-S activities performed at the installation site
6.3
Adding loggers to the GT-3-S group
Introduction You have already created a GT-3-S group in the directory tree of the SDV-3 software.
All loggers that are to be connected to the GT-3-S must now be added to this group.
A maximum of three loggers per group is possible.
Procedure Open the SDV-3 software on the laptop.
Then proceed as follows:
Step Description
Mark the relevant group in the directory tree.
If you wish to register a N-3 noise
If you wish to register a P-3 pressure
logger, open the LogN3 tab in the menu logger, open the LogP tab in the menu
bar.
bar.
Click New in the Administration segment.
Result: The window for logger registration opens.
Switch on the first logger to be registered. The logger will be detected
automatically, and its identification number (ID) is shown.
Use the Insert button to copy the ID shown into the directory tree.
(Alternatively: if you deactivate the “Automatic detection” checkbox, you can enter
the ID of the logger manually.)
Result: The logger is now displayed in the directory tree. You will find it in the
group for the GT-3-S with which it will be connected later on.
Add all other loggers to be connected to this GT-3-S to the group the same way.
Use the Close button to end the registration process.
32
GT-3-S activities performed at the installation site
6.4
Installing devices in the shaft
6.4.1
Installing loggers
Install the logger/s in the GT-3-S group in the shaft.
Detailed information on correct installation can be found in the operating manuals for the
loggers.
If you install an N-3 noise logger horizontally, make sure that the red marking on
the logger points upwards.
6.4.2
Installing GT-3-S
Make sure that the GT-3-S is switched on. The status LED flashes regularly in blue.
Positioning the GT-3-S Place the GT-3-S in the shaft. The device can be suspended or be positioned vertically
or horizontally to suit the on-site conditions. When possible, the connection sockets on
the device should point downwards.
Suspending the device in the shaft, as shown in the following figure, is ideal. This device
has been installed suspended in a service shaft using cable ties, just below the shaft
opening.
Note: Do not suspend the GT-3-S by the cables.
Positioning the aerial The GSM/GPS aerial connected to the GT-3-S can not receive a GPS signal when it is
inside the shaft, and is only able to connect to the mobile network under certain
conditions.
The aerial should therefore be guided out of the shaft, and be positioned outside.
Note: • Do not bend or pinch the connection cable, or damage it in any other way.
• Do not subject the connection cable to strain.
• In order to receive GPS signals, the aerial must have an unobstructed “view”
of the sky. Glass or plastic surface are not usually an obstacle to GPS
signals. Walls, ceiling or other obstacles made of metal or stone do, however,
inhibit GPS reception.
If there is nowhere to securely and safely install the aerial, or when the aerial should not
be easily visible, then it can be buried a few centimetres deep in the ground.
33
GT-3-S activities performed at the installation site
6.5
Programming noise loggers (Log N-3)
This section is not relevant for Log P-3 / Log P-3 mini pressure loggers.
Introduction When programming the GT-3-S in the office, you defined whether the device should
send alarm messages in the event of an alarm or not.
An alarm on an N-3 logger occurs when the lowest value recorded by the logger
(minimum value) has reached or exceeded a specific threshold at the end of a
measuring period. As a result, the GT-3-S sends alarm messages or triggers other
alarm measures, depending on which alarm activities were defined by the use when
programming the GT-3-S.
The noise level that is to form the alarm threshold must be defined individually for each
N-3 logger. You also have the option of adding a comment text to each logger.
Note: It is important to perform these tasks before sending the configuration to the
GT-3-S.
Procedure Proceed as follows:
Step Description
Mark the required logger in the directory tree of the SDV-3.
Click on Program in the menu bar.
Result: A new window opens.
Enter the value that should form the alarm threshold value for this logger in the
Leak threshold field. Values between 1 and 60 are possible.
1 P Stands for the lowest noise level that can be measured.
60 P Stands for the highest noise level that can be measured.
You can leave notes and remarks about the logger under Comment.
Click on OK to confirm the input and to close the window.
Enter the alarm threshold value the same way for all other N-3 loggers in the group.
If the leak threshold of a logger proves to be too low or too high after a few
measurement days, you can reprogram the GT-3-S group on site or by remote
configuration, and modify the leak thresholds when doing so.
If you do not specify a leak threshold, “10” will be the leak threshold value that is
automatically used by the loggers.
34
GT-3-S activities performed at the installation site
6.6
Programming pressure loggers (Log P-3 / P-3 mini)
This section is not relevant for Log N-3 noise loggers.
Introduction When programming the GT-3-S in the office, you entered a number of measurement
settings which apply for all loggers in the group in equal measure, such as the
measurement days and the exact measurement period.
Other measurement settings, in turn, must be made individually for each pressure
logger in the group, such as the measuring interval.
Note: It is important to perform these tasks before sending the configuration to the
GT-3-S.
Procedure Proceed as follows:
Step Description
Mark the required logger in the directory tree of the SDV-3.
Click on Program in the menu bar.
Result: A new window opens.
Set the measuring interval for this logger.
Use the drop-down menu under Log interval to do so.
Select the measuring unit for the measurements recorded.
Use the drop-down menu under Unit to do so.
Activate the Record pressure shocks checkbox when pressure fluctuations that
occur suddenly (so-called pressure surges) should be recorded along with the
standard pressure measurement. In the event of a pressure surge, a 60-second
recording then starts.
Use the input field to the right of the checkbox to define by how much a measured
value must differ from the preceding measured value for a pressure fluctuation to
be considered a pressure surge.
Example: If a value of “0.5” is entered, then a pressure surge recording will start
as soon as a measured value is at least 0.5 units above or below the last value
measured.
Use the High resolution checkbox to define which measuring interval should
apply for the 60-second pressure surge recording:
• Checkbox not activated: Sampling interval 1 sec.
• Checkbox activated: Sampling interval 0.1 sec.
The shorter measuring interval of 0.1 sec. allows a more detailed recording of the
pressure surge.
Please note that recording pressure surges at high resolution uses more
energy, and will have a negative effect on the logger battery lifespan.
You can leave notes and remarks about the logger under Comment.
Click on OK to confirm the input and to close the window.
35
GT-3-S activities performed at the installation site
6.7
Sending the configuration to the GT-3-S
Introduction This step involves sending the GT-3-S configuration data from the computer to the
GT-3-S.
You may have already performed this step during preparations in the office. This was
necessary to be able to test whether the mobile connection functions there. This step
must be repeated to ensure that the latest configuration data have been sent to the
GT-3-S and the loggers.
Procedure Proceed as follows:
Step Description
Mark the GT-3-S concerned in the directory tree of the SDV-3.
Click on Program in the menu bar.
Result: The window for input of the configuration data opens.
If this GT-3-S was already created and programmed during preparations in the
office, then now check the data displayed, and make any changes necessary.
If this GT-3-S was only recently created and has not been programmed, now
enter the required configuration data.
Does this group include N-3 noise loggers with noise recordings that are
to be correlated with recordings by other loggers later on? Then the
Sync to GPS checkbox, found at the bottom of the configuration
window, must be activated.
Click on Program at the bottom right of the window.
Result: The configuration data are then sent to the GT-3-S by the computer.
After completing the process, a dialogue window appears. You will be asked
whether you would like to continue with the next step directly.
36
GT-3-S activities performed at the installation site
6.8
Synchronising the GT-3-S with GPS
This step involves synchronising the internal clock of the GT-3-S with GPS time. The
GPS position of the device is also determined.
This step is essential if you are working with N-3 noise loggers with measured data that
are to be used for a correlation later on.
Requirement The following prerequisites must be met:
• The Sync to GPS option must be activated in the GT-3-S configuration.
• The GT-3-S should already be installed in the shaft, and the aerial be correctly
positioned.
Procedure Proceed as follows:
Step Description
Answer the question in the dialogue that appears with “Yes” or click on
Sync to GPS in the menu bar.
Result: A new window opens.
Click on Start in the window.
Result: The internal GPS module in the GT-3-S is activated. The device starts
searching for available satellites.
As soon as the current GPS time has been received, it appears on the computer.
As soon as the GPS position data have been received, the latitude and longitude
also appear. This process can take some time.
You can cancel the GPS search at any time using the Stop button.
The GPS search is automatically stopped after 3 minutes to save energy.
Once the GPS search is successful, a success message appears on the screen,
followed by a dialogue window. You will be asked whether you now wish to
continue with the next step.
You can repeat this process at any time.
To do so, mark the GT-3-S concerned in the directory tree of the SDV-3 and click
on Sync to GPS in the menu bar.
6.9
“Linking” GT-3-S to loggers
This step involves “linking” the GT-3-S to the loggers in the group, meaning the GT-3-S
sends the configuration data to the loggers. The internal clocks in the loggers are also
synchronised with the internal time used by the GT-3-S.
Requirement The loggers in the group must be switched on.
The loggers and the GT-3-S should already be installed in the shaft.
Procedure Answer the question in the dialogue that appears with “Yes” or click on Link to logger in
the menu bar.
Result: The GT-3-S successively contacts all loggers in the group by radio.
Once the process is complete, a message appears on the screen informing you whether
the “linking” process was successful. The message also includes details about the
quality of the radio connection between the GT-3-S and the loggers.
37
GT-3-S activities performed at the installation site
You can repeat this process at any time.
To do so, mark the GT-3-S concerned in the directory tree of the SDV-3 and click
on Link to logger in the menu bar.
6.10
Performing the GSM test and closing the shaft
Now perform a GSM test to check whether the GT-3-S can connect to the mobile
network properly at the usage site.
Closing the shaft before the test is recommended to obtain a realistic result. Otherwise,
once the shaft is closed, there may not be a radio connection between the computer and
the GT-3-S, and the test might not start.
Therefore, proceed as follows:
Step Description
Start the GSM test.
For that, mark the GT-3-S concerned in the directory tree of the SDV-3, then click
on Check GSM in the menu bar.
Close the shaft.
Note: Do not bend or pinch the connection cable, or damage it in any other way.
Wait for the test result.
(You will find more detailed information about the GSM test in a separate section).
All devices ready for Has the GSM test been successful? Then all devices of the group are now ready for the
measurement upcoming measurement.
38
GT-3-S activities performed at the installation site
Tento symbol indikuje, že výrobek nesoucí takovéto označení nelze likvidovat společně s běžným domovním odpadem. Jelikož se jedná o produkt obchodovaný mezi
podnikatelskými subjekty (B2B), nelze jej likvidovat ani ve veřejných sběrných dvorech. Pokud se potřebujete tohoto výrobku zbavit, obraťte se na organizaci specializující
se na likvidaci starých elektrických spotřebičů v blízkosti svého působiště.
Dit symbool duidt aan dat het product met dit symbool niet verwijderd mag worden als gewoon huishoudelijk afval. Dit is een product voor industrieel gebruik, wat betekent
dat het ook niet afgeleverd mag worden aan afvalcentra voor huishoudelijk afval. Als u dit product wilt verwijderen, gelieve dit op de juiste manier te doen en het naar een
nabij gelegen organisatie te brengen gespecialiseerd in de verwijdering van oud elektrisch materiaal.
This symbol indicates that the product which is marked in this way should not be disposed of as normal household waste. As it is a B2B product, it may also not be disposed
of at civic disposal centres. If you wish to dispose of this product, please do so properly by taking it to an organisation specialising in the disposal of old electrical equipment
near you.
Този знак означава, че продуктът, обозначен по този начин, не трябва да се изхвърля като битов отпадък. Тъй като е B2B продукт, не бива да се изхърля и в
градски пунктове за отпадъци. Ако желаете да извърлите продукта, го занесете в пункт, специализиран в изхвърлянето на старо електрическо оборудване.
Dette symbol viser, at det produkt, der er markeret på denne måde, ikke må kasseres som almindeligt husholdningsaffald. Eftersom det er et B2B produkt, må det heller ikke
bortskaffes på offentlige genbrugsstationer. Skal dette produkt kasseres, skal det gøres ordentligt ved at bringe det til en nærliggende organisation, der er specialiseret i at
bortskaffe gammelt el-udstyr.
Sellise sümboliga tähistatud toodet ei tohi käidelda tavalise olmejäätmena. Kuna tegemist on B2B-klassi kuuluva tootega, siis ei tohi seda viia kohalikku jäätmekäitluspunkti.
Kui soovite selle toote ära visata, siis viige see lähimasse vanade elektriseadmete käitlemisele spetsialiseerunud ettevõttesse.
Tällä merkinnällä ilmoitetaan, että kyseisellä merkinnällä varustettua tuotetta ei saa hävittää tavallisen kotitalousjätteen seassa. Koska kyseessä on yritysten välisen kaupan
tuote, sitä ei saa myöskään viedä kuluttajien käyttöön tarkoitettuihin keräyspisteisiin. Jos haluatte hävittää tämän tuotteen, ottakaa yhteys lähimpään vanhojen
sähkölaitteiden hävittämiseen erikoistuneeseen organisaatioon.
Ce symbole indique que le produit sur lequel il figure ne peut pas être éliminé comme un déchet ménager ordinaire. Comme il s’agit d’un produit B2B, il ne peut pas non plus
être déposé dans une déchetterie municipale. Pour éliminer ce produit, amenez-le à l’organisation spécialisée dans l’élimination d’anciens équipements électriques la plus
proche de chez vous.
Cuireann an siombail seo in iúl nár cheart an táirgeadh atá marcáilte sa tslí seo a dhiúscairt sa chóras fuíoll teaghlaigh. Os rud é gur táirgeadh ghnó le gnó (B2B) é, ní féidir
é a dhiúscairt ach oiread in ionaid dhiúscartha phobail. Más mian leat an táirgeadh seo a dhiúscairt, déan é a thógáil ag eagraíocht gar duit a sainfheidhmíonn i ndiúscairt
sean-fhearas leictrigh.
Dieses Symbol zeigt an, dass das damit gekennzeichnete Produkt nicht als normaler Haushaltsabfall entsorgt werden soll. Da es sich um ein B2B-Gerät handelt, darf es
auch nicht bei kommunalen Wertstoffhöfen abgegeben werden. Wenn Sie dieses Gerät entsorgen möchten, bringen Sie es bitte sachgemäß zu einem Entsorger für
Elektroaltgeräte in Ihrer Nähe.
Αυτό το σύµβολο υποδεικνύει ότι το προϊόν που φέρει τη σήµανση αυτή δεν πρέπει να απορρίπτεται µαζί µε τα οικιακά απορρίµατα. Καθώς πρόκειται για προϊόν B2B, δεν
πρέπει να απορρίπτεται σε δηµοτικά σηµεία απόρριψης. Εάν θέλετε να απορρίψετε το προϊόν αυτό, παρακαλούµε όπως να το παραδώσετε σε µία υπηρεσία συλλογής
ηλεκτρικού εξοπλισµού της περιοχής σας.
Ez a jelzés azt jelenti, hogy az ilyen jelzéssel ellátott terméket tilos a háztartási hulladékokkal együtt kidobni. Mivel ez vállalati felhasználású termék, tilos a lakosság
számára fenntartott hulladékgyűjtőkbe dobni.Ha a terméket ki szeretné dobni, akkor vigye azt el a lakóhelyéhez közel működő, elhasznált elektromos berendezések
begyűjtésével foglalkozó hulladékkezelő központhoz.
Questo simbolo indica che il prodotto non deve essere smaltito come un normale rifiuto domestico. In quanto prodotto B2B, può anche non essere smaltito in centri di
smaltimento cittadino. Se si desidera smaltire il prodotto, consegnarlo a un organismo specializzato in smaltimento di apparecchiature elettriche vecchie.
Šī zīme norāda, ka iztrādājumu, uz kura tā atrodas, nedrīkst izmest kopā ar parastiem mājsaimniecības atkritumiem. Tā kā tas ir izstrādājums, ko cits citam pārdod un lieto
tikai uzņēmumi, tad to nedrīkst arī izmest atkritumos tādās izgāztuvēs un atkritumu savāktuvēs, kas paredzētas vietējiem iedzīvotājiem. Ja būs vajadzīgs šo izstrādājumu
izmest atkritumos, tad rīkojieties pēc noteikumiem un nogādājiet to tuvākajā vietā, kur īpaši nodarbojas ar vecu elektrisku ierīču savākšanu.
Šis simbolis rodo, kad juo paženklinto gaminio negalima išmesti kaip paprastų buitinių atliekų. Kadangi tai B2B (verslas verslui) produktas, jo negalima atiduoti ir buitinių
atliekų tvarkymo įmonėms. Jei norite išmesti šį gaminį, atlikite tai tinkamai, atiduodami jį arti jūsų esančiai specializuotai senos elektrinės įrangos utilizavimo organizacijai.
Dan is-simbolu jindika li l-prodott li huwa mmarkat b’dan il-mod m’għandux jintrema bħal skart normali tad-djar. Minħabba li huwa prodott B2B , ma jistax jintrema wkoll
f’ċentri ċiviċi għar-rimi ta’ l-iskart. Jekk tkun tixtieq tarmi dan il-prodott, jekk jogħġbok għamel dan kif suppost billi tieħdu għand organizzazzjoni fil-qrib li tispeċjalizza fir-rimi ta’
tagħmir qadim ta’ l-elettriku.
Dette symbolet indikerer at produktet som er merket på denne måten ikke skal kastes som vanlig husholdningsavfall. Siden dette er et bedriftsprodukt, kan det heller ikke
kastes ved en vanlig miljøstasjon. Hvis du ønsker å kaste dette produktet, er den riktige måten å gi det til en organisasjon i nærheten som spesialiserer seg på kassering av
gammelt elektrisk utstyr.
Ten symbol oznacza, że produktu nim opatrzonego nie należy usuwać z typowymi odpadami z gospodarstwa domowego. Jest to produkt typu B2B, nie należy go więc
przekazywać na komunalne składowiska odpadów. Aby we właściwy sposób usunąć ten produkt, należy przekazać go do najbliższej placówki specjalizującej się w
usuwaniu starych urządzeń elektrycznych.
Este símbolo indica que o produto com esta marcação não deve ser deitado fora juntamente com o lixo doméstico normal. Como se trata de um produto B2B, também não
pode ser deitado fora em centros cívicos de recolha de lixo. Se quiser desfazer-se deste produto, faça-o correctamente entregando-o a uma organização especializada na
eliminação de equipamento eléctrico antigo, próxima de si.
Acest simbol indică faptul că produsul marcat în acest fel nu trebuie aruncat ca şi un gunoi menajer obişnuit. Deoarece acesta este un produs B2B, el nu trebuie aruncat nici
la centrele de colectare urbane. Dacă vreţi să aruncaţi acest produs, vă rugăm s-o faceţi într-un mod adecvat, ducând-ul la cea mai apropiată firmă specializată în colectarea
echipamentelor electrice uzate.
Tento symbol znamená, že takto označený výrobok sa nesmie likvidovať ako bežný komunálny odpad.Keďže sa jedná o výrobok triedy B2B, nesmie sa likvidovať ani na
mestských skládkach odpadu. Ak chcete tento výrobok likvidovať, odneste ho do najbližšej organizácie, ktorá sa špecializuje na likvidáciu starých elektrických zariadení.
Ta simbol pomeni, da izdelka, ki je z njim označen, ne smete zavreči kot običajne gospodinjske odpadke. Ker je to izdelek, namenjen za druge proizvajalce, ga ni dovoljeno
odlagati v centrih za civilno odlaganje odpadkov. Če želite izdelek zavreči, prosimo, da to storite v skladu s predpisi, tako da ga odpeljete v bližnjo organizacijo, ki je
specializirana za odlaganje stare električne opreme.
Este símbolo indica que el producto así señalizado no debe desecharse como los residuos domésticos normales. Dado que es un producto de consumo profesional,
tampoco debe llevarse a centros de recogida selectiva municipales. Si desea desechar este producto, hágalo debidamente acudiendo a una organización de su zona que
esté especializada en el tratamiento de residuos de aparatos eléctricos usados.
Den här symbolen indikerar att produkten inte får blandas med normalt hushållsavfall då den är förbrukad. Eftersom produkten är en så kallad B2B-produkt är den inte
avsedd för privata konsumenter, den får således inte avfallshanteras på allmänna miljö- eller återvinningsstationer då den är förbrukad. Om ni vill avfallshantera den här
produkten på rätt sätt, ska ni lämna den till myndighet eller företag, specialiserad på avfallshantering av förbrukad elektrisk utrustning i ert närområde.
39

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 39
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:7ee517ba-908b-11e7-0000-d0a51a901217
Producer                        : GPL Ghostscript 9.14
Keywords                        : 
Modify Date                     : 2017:08:31 11:37:25+02:00
Create Date                     : 2017:08:31 11:37:25+02:00
Creator Tool                    : PDF24 Creator
Document ID                     : uuid:7ee517ba-908b-11e7-0000-d0a51a901217
Format                          : application/pdf
Title                           : 
Creator                         : 
Description                     : 
Author                          : 
Subject                         : 
EXIF Metadata provided by EXIF.tools
FCC ID Filing: OV8-LOGRIP

Navigation menu