Sebury Technology W3-H ACCESS CONTROL User Manual

Sebury Technology Co., Ltd. ACCESS CONTROL Users Manual

Users Manual

User Manual
.8. .10.
D0 D0
D1 D1
ALARM-
OPEN
D_IN
DC /3A12V
W3-H
Door d etecti ng switch
--
++
-
+
Special Power Su pply
Alarm
GND
AC&DC
AC&DC
NC
COM
NO
NC COM NO +1 2V GN D
V+
GND
OPE N
Green
White
Grey
Yell ow
Brown
Red
Black
Blue
Purple
Orange
Pink
Exit button
Wiegand reade r
Fail -Secu re lock
Fai l-Sec ure lock
Figu re 2
Transmission Format:
1: Keypad Transmission
The Reader will transmit the PIN data when it receives the last key (#) press after PIN
code.
Format: PIN Code ( any 4-8 digits between 0000-99999999)
Example: PIN code:111111
Press 111111 #, then the output format will be: 0000111111
(
l 2: Proximity Card Transmission
The Reader will transmit the card data when it reads the Card.
Format: Card Number
(Note: No matter the card is valid or invalid, the data will be transmitted)
l
Note: if press an invalid PIN (any 4-8 digits), the data will be also transmitted.)
14.2 W3-H operating as a Controller
In this mode the W3-H supports a Wiegand 26-37 bit input so an external Wiegand
device with a 26-37 bit output can be connected to the Wiegand input terminals on the
W3-H. Either an ID card reader (125KHz) or an IC card reader (13.56MHz) can be
connected to the W3-H. Cards are required to be added at the external reader, except
where an external HID reader is used, in this case cards can be added at either reader
or controller. See figure 2.
D0
D1
ALARM-
OPEN
D_IN
W3-H
GND
AC&DC
AC&DC
NC
COM
NO
Controller
V+
V+
GND
GND
D0
D1
Power
Green
White
Grey
Yellow
Brown
Red
Black
Blue
Purple
Orange
Pink
Figure 1
W3-H Quick Reference Programming Guide
To enter the programming mode * Master code #
888888 is the default factory master code
To exit from the programming mode *
Note that to undertake the following programming the master user must be logged in
To change the master code 0 New code # New code #
The master code can be 6 digits long
1 User ID number # PIN #
The ID number is any number between
1-2,000. The PIN is any 4-8 digits between
0000 - 99999999 with the exception of 1234
which is reserved. Users can be added
continuously without exiting programming
mode
To add a PIN user
1 Read Card #
Cards can be added continuously without
exiting from programming mode
To add a Card user
To delete a PIN or a Card user 2 User ID number # for a PIN user or
2 Read Card # for a card user
To unlock the door
To unlock the door for a PIN user
To unlock the door for a card user
Enter the PIN then press #
Present the card
.7.
To change a PIN in card and PIN
mode (Method 1)
Note that this is done outside
programming mode so the user can
undertake this themselves
To change a PIN in card and PIN
mode (Method 2)
Note that this is done out
programming mode so the user can
undertake this themselves
side
To delete a Card and PIN user just
delete the card
* Read Card Old PIN # New PIN # New PIN #
* ID number # Old PIN # New PIN #
New PIN #
2 User ID #
.9.
To set keypad tone
7 8 # To disable the keypad tone
7 9 #
To enable the keypad tone(Factory default)
To set LED
7 6 # To disable the red LED
7 7 #
To enable the red LED(Factory default)
13. Wiegand Mode Setting
W3-H supports Wiegand 26-37, both input and output. It can be used as a reader or controller.
To set Wiegand format: 9 26-37 # (Default setting: Wiegand 26)
14. Interconnecting Two Devices
14.1 W3-H operating as a Wiegand Output Reader
In this mode the W3-H supports a Wiegand 26-37 bit output so the Wiegand data lines
can be connected to any controller which supports a Wiegand 26-37 bit input.
See figure 1.
To set Duress PIN user
12. Duress User Settings
There are 10 groups Duress PIN/card available. When input Duress PIN/card, the door
will open, at the same time, the output alarm operates.
To add a PIN user
To delete a PIN user
2
To set Dur ss card usere
To add a card user
To delete a card user
(The ID number is any number between 2001 2010)-
Note:
User ID number must be any 4digits between 2001 2010
Duress PIN/card must be unique, should be distinguished from common PIN and card
(When the Duress PIN/card is the same with common PIN and card, they will become invalid
in Duress, and worked as common user function)
-
(The ID number is any number between 2001-2010)
2
To remove the alarm
To reset the Door Forced Open warning
Read Valid Card or Master Code #
To reset the Door Open Too Long warning Close the door or Read Valid Card or Master Code #
W3-H Waterproof
Keypad/Reader/Controller
1. Packing list
Name
Digital Keypad W3-H
Quantity Remark
Screw Driver
Rubber Bungs
Self Tapping Screws
Diode
1
4
4
1
6*27mm, used for fixing
4*28mm, used for fixing
IN4004
User Manual 1
1
Please ensure that all the above contents are correct. If any are missing please notify
the supplier of the W3-H.
.1.
Manager Card 2Manager Add Card & Manager Delete Card
The W3-H is a single door multifunction access control with HID card reader. It is
suitable for mounting either indoor or outdoor in harsh environments. It is housed in a
strong, sturdy and vandal proof zinc alloy electroplated case. The electronics are fully
potted so the W3-H is waterproof and conforms to IP68.
The W3-H supports up to 2,000 users in either a Card, 4-8 digits PIN, or a Card + PIN
option and additional 10 groups Duress PIN/Card. The built-in card reader supports HID
125KHz frequency cards/tags. The W3-H has many extra features including Duress
PIN/card, block enrollment, Wiegand 26-37 bits interface, and backlight keypadetc.
These features make W3-H an ideal choice for door access not only for small shops and
domestic households but also for commercial and industrial applications such as
factories, warehouses, laboratories, banks and prisons.
2. Description
Waterproof, conforms to IP 68
Strong zinc alloy electroplated anti-vandal case
Full programming from the keypad
2,000 users, supports Card, PIN, Card + PIN
10 groups Duress PIN/Card
Card interface: HID 125KHz Card
Can be used as a standalone keypad, PIN length 4-8 digits
Pulse mode, Toggle mode
l
l
l
l
l
l
l
l
3. Features
.2.
PCB connect diagram
Ant i-dem oliti on alar m
D0
D1
ALARM-
OPEN
D_IN
GND
AC&DC
AC&DC
NC
COM
NO
J1
D0
D1
ALA RM-
OPE N
D_I N
GND
AC& DC
AC& DC
NC
COM
NO
J1
W3-H
5. Installation
l
l
l
l
l
Remove the back cover from the keypad using the supplied security screwdriver
Drill 4 holes on the wall for the screws and 1 hole for the cable
Fix the back cover firmly on the wall with 4 flat head screws
Thread the cable through the cable hole
Attach the keypad to the back cover
.3.
4. Specifications
Operating Voltage 12-24V DC or 1 -18V AC2
2,000 (Additional10 groups Duress PIN/Card)
Adjustable Door Relay Time
Adjustable Alarm Time
Wiegand Interface
Wiring Connections
Wiegand 26-37 input & output
L128 X W82 X H28mm
600 g
700 g
12 keys: 3 X 4 digits
Operating Humidity
Dimensions
Net Weight
Gross Weight
10%-90% RH
1-99 seconds
Electric Lock, Exit Button, DOTL, External Alarm
Operating Temperature -20-50
HID 125KHz card
3-6 cm
Max 2A
Max 20A
User Capacity
Keypad
Card Type
Card Reading Distance
Lock Output Load
Alarm Output Load
Active Current
Idle Current
65mA
35mA
Environment Conforms to IP68
0-3 minutes
6. Wiring
Colour
Grey
Yellow
Brown
Red
Black
Blue
Purple
Function
D0
Alarm -
OPEN
D-IN
12-24V DC or 12-18V AC
NO
COM
Description
Wiegand Output D0
White Wiegand Output D1
Request to Exit Button
Door Contact
12-24V DC or 12-18V AC Regulated Power Input
12-24V DC or 12-18V AC Regulated Power Input
Alarm Negative
Orange NC
Pink GND
Green
D1
Relay NO
Relay COM
Relay NC
W3-H Negative
12-24V DC or 12-18V AC
.4.
The relay on board can operate in Pulse Mode (suitable for access control) or Toggle
Mode (suitable for arming/disarming alarms, switching lights, machines.etc)
Every time a valid tag/card or PIN is read/input in Pulse Mode, the relay will operate, for
the pre-set relay pulse time.
Every time a valid tag/card or PIN is read/input in Toggle Mode, the relay changes state,
which will not turn back until read card or input PIN again.
8. Relay operation (Pulse mode and Toggle mode)
9. To Reset to Factory Default
To reset to factory default, power off, press , hold it and power on, release it until hear
two beeps and the LED shines in orange, then read any two HID cards, the LED will turn
in red, means reset to factory default setting successfully. Of the two HID cards read, the
first one is Manager Add Card, the second one is Manager Delete Card.
Remarks: Reset to factory default, the user's information is still retained.
*
7. Anti Tamper Alarm
The W3-H uses a LDR (light dependent resistor) as an anti tamper alarm. If the keypad
is removed from the cover then the tamper alarm will operate.
.5. .6.
10. Sound and Light Indication
Operation Status
Power on
Operation successful
Operation failed
Enter into programming mode
Red Light
-
-
-
Bright
Bright
Bright
Green Light
-
-
Bright
-
-
-
Buzzer
Short Ring
-
Short Ring
Short Ring
3 Short Ring
Short Ring
-
Short Ring
Press keypad
--
Stand by
In the programming mode
Exit from the programming mode
Open the door
Bright
-
Bright Alarm
-
Alarm
Bright
-
Short Ring
Yellow Light
-
-
-
-
-
Bright
-
-
-
-
11. W3-H Detailed Programming Guide
11.1 User Settings
To exit from the programming mode
To change the master code
set valid card only users
set valid card and PIN users
set valid card or PIN users
*
Master code
#
888888 is the default factory master code
To enter the programming mode
*
Note that to undertake the following programming the master user must be logged in
0 New code # New code #
The master code is any 6 digits
Setting the working mode:
3 0 #
3 1 #
3 2 # Entry by either Card or PIN (default)
Entry by Card only
Entry by Card and PIN together
To set a user in either card or PIN mode ( 3 2 # ) (Default setting)
To add a PIN user
1 User ID number # PIN #
The ID number is any number between 1-
2000. The PIN is any 4-8 digits between 0000
-99999999 with the exception of 1234 which
is reserved. Users can be added continuously
without exiting from programming mode as
follows:
1 User ID No 1 # PIN # User ID No 2 # PIN #
To delete a PIN user 2 User ID number #
Users can be deleted continuously without
exiting programming mode
To delete card user by card
Note users can be deleted
continuously without exiting
from programming mode
2 Read Card #
To delete a card user by user ID
This option can be used when a
user has lost their card
2 User ID #
To add a card user (Method 3)
Add a series cards users - Block
Enrollment
5 ID number # The 1st Card number #
Card quantity #
Note that cards must be consecutive, and card
quantity is between 1-2000
Maximum 2,000 cards can be enrolled at a
stretch within 2 minutes
To delete card user by card number
Users can be deleted
continuously without exiting
from programming mode
a2 Card number #
To set a card and PIN user in card and PIN mode ( 3 1 # )
To Add a card and PIN user
(The PIN is any 4-8 digits between
0000 - 99999999 with the
exception of 1234 which is
reserved)
Add the card as for a card user
Press to exit from the programming mode
Then allocate the card a PIN as follows:
Read Card 1234 # PIN # PIN #
*
*
To change the PIN of a PIN user
(This step must be done out of
programming mode)
To add a card user (Method 1)
This is a fastest way to add cards
using ID number auto generation
To add a card user (Method 2)
Th is i s t he opti o na l way to a dd
cards using User ID Allocation.
In this method a User ID is allocated
to a card. Only one user ID can be
allocated to a single card
ID number # Old PIN # New PIN #
New PIN #
*
1 ID number # Card #
1 Read Card #
Cards can be added continuously without exiting
programming mode
l
l
l
l
Wiegand 26-37 input & output
One programmable relay output, NO, NC, COM
Adjustable door output time, alarm time, door open time
Card block enrollment
l
l
l
l
l
l
l
With Manager Cards for adding or deleting card user easily
Backlight keypad
Built in light dependent resistor (LDR) for anti tamper
Built in buzzer
Red, Yellow and Green LED display the working status
12-24V DC or 12-18V AC
Two-year warranty
W3-H
D0
D1
ALARM-
OPEN
D_IN
DC /3A12V
-
+
Wiega nd D0
Wiega nd D1
GND
AC&DC
AC&DC
NC
COM
NO
NC COM NO +12V GN D OPEN
Green
White
Grey
Yellow
Brown
Red
Black
Blue
Purple
Orange
Pink
Door
detec ting sw itch
Exit bu tto n
Alarm
Power
+
-
+
-
Fail-secure lock
Alarm-
Special Power Supply
Connection Giagram
To add Card User by Manager Add
Card
To set card users by Manager card
To delete Card User by Manager
Delete Card
Manager add card Read User card
Manager add card
Cards can be added continuously
Manager delete card Read User Card
Manager delete card
Cards can be deleted continuously
For a PIN user Enter the PIN then press #
For a card user Read card
For a card and PIN user Read card then enter PIN #
To unlock the door
To Add and Delete a card user
To delete All users
To delete ALL users
Note that this is a dangerous option
so use with care
The operating is the same as adding and deleting
a card user in 3 2 #
2 0000 #
To set a card user in card mode ( 3 0 # )
Common Power Supply
D0
D1
ALARM-
OPEN
D_IN
Exit button
W3-H
-
+
Green
White
Grey
Yellow
Brown
Red
Black
Blue
Purple
Orange
Power
Alarm
GND
AC&DC
AC&DC
NC
COM
NO
Pink
-
+
Lock
In4004
Power+
Electric boltNC
Electric strikeNO
Power+
Alarm -“ ”
Door
detecting switch
12-24V DC or
12-18V AC/3A
Notes:
Connect the negative pole of the lock to NC is for Fail safe lock.
Connect the negative pole of the lock to NO is for Fail-secure lock.
Keypad Lockout
Alarm Output
Normal status: No keypad lockout
or alarm
7 0 # (Factory default)
7 1 #
7 2 #
Keypad Lockout & Alarm Output options. If there are 10 invalid cards or 10
incorrect PIN numbers in a 10 minute period either the keypad will lockout for 10
minutes or the alarm will operate for 10 minutes, depending on the option selected
below.
Light and Sound Setting
To set the alarm output time (0-3
minutes). Factory default is 1 minute
Alarm output time
9 0-3 #
To disable door open detection
Door Open Detection
Door Open Too Long (DOTL) warning. When used with an optional magnetic contact
or built-in magnetic contact of the lock, if the door is opened normally, but not closed
after 1 minute, the inside buzzer will beep automatically to remind people to close the
door and continue for 1 minute before switching off automatically.
Door Forced Open warning. When used with an optional magnetic contact or built-in
magnetic contact of the lock, if the door is open by , or if the door is opened after
20 seconds of the electro-mechanical lock not closed properly, the inside buzzer and
alarm output will both operate. The Alarm Output time is adjustable between 0-3
minutes with the default being 1 minute.
force
To enable door open detection 6 1 #
11.3 Alarm, Sound and Light SettingsDoor Detection,
To set keypad backlight
7 4 #
7 5 #
To enable keypad backlight(Factory default)
Toggle mode
Toggle mode 4 0 #
Pulse mode
(Door relay time setting)
Pulse mode(Factory default)
11.2 Relay Setting (Pulse mode,Toggle mode)
4 1-99 #
The door relay time is between 1-99 seconds,
the factory default setting is 5 seconds.
6 0 #
(Factory default )
To disable keypad backlight
FCC WARNING
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause
undesired operation.
NOTE 1: Any changes or modifications to this unit not expressly approved by the party
responsible for compliance could void the user's authority to operate the equipment.

Navigation menu