Sebury Technology W3-H ACCESS CONTROL User Manual
Sebury Technology Co., Ltd. ACCESS CONTROL Users Manual
Users Manual
11.2 Relay Setting (Pulse mode,Toggle mode) To change a PIN in card and PIN mode (Method 1) Note that this is done outside programming mode so the user can undertake this themselves * Read Card Old PIN # New PIN # New PIN # Pulse mode(Factory default) * ID number # Old PIN # New PIN # New PIN # Pink To disable the red LED To enable the red LED(Factory default) 4 1-99 # The door relay time is between 1-99 seconds, the factory default setting is 5 seconds. Toggle mode 7 8 # 7 9 # To set keypad tone 4 0 # GND V+ Read Valid Card or Master Code # To reset the Door Open Too Long warning V+ GND Close the door or Read Valid Card or Master Code # Controller 11.3 Door Detection, Alarm, Sound and Light Settings 2 User ID # To set a card user in card mode ( 3 W3-H Quick Reference Programming Guide To enter the programming mode * Master code # 888888 is the default factory master code To exit from the programming mode Note that to undertake the following programming the master user must be logged in 0 # ) The operating is the same as adding and deleting a card user in 3 2 # To Add and Delete a card user To delete All users To delete ALL users Note that this is a dangerous option so use with care 2 0000 # 0 New code # New code # The master code can be 6 digits long To change the master code To add a PIN user 1 Read Card # Cards can be added continuously without exiting from programming mode To add a Card user To delete a PIN or a Card user User ID number # for a PIN user or Read Card # for a card user To unlock the door To add Card User by Manager Add Card Manager add card Read User card Manager add card Cards can be added continuously To delete Card User by Manager Delete Card Manager delete card Read User Card Manager delete card Cards can be deleted continuously To unlock the door For a PIN user For a card user To unlock the door for a PIN user Enter the PIN then press # To unlock the door for a card user Present the card For a card and PIN user Enter the PIN then press # Read card Read card then enter PIN # OPEN Brown D_IN Door Forced Open warning. When used with an optional magnetic contact or built-in magnetic contact of the lock, if the door is open by force , or if the door is opened after 20 seconds of the electro-mechanical lock not closed properly, the inside buzzer and alarm output will both operate. The Alarm Output time is adjustable between 0-3 minutes with the default being 1 minute. To disable door open detection 6 0 # (Factory default ) To enable door open detection 6 1 # AC&DC Blue NO Purple COM Orange NC To set the alarm output time (0-3 minutes). Factory default is 1 minute 9 0-3 # Keypad Lockout & Alarm Output options. If there are 10 invalid cards or 10 incorrect PIN numbers in a 10 minute period either the keypad will lockout for 10 minutes or the alarm will operate for 10 minutes, depending on the option selected below. Normal status: No keypad lockout 7 0 # (Factory default) or alarm 7 1 # Alarm Output 7 2 # To add a PIN user (The ID number is any number between 2001-2010) To delete a PIN user 1: Keypad Transmission The Reader will transmit the PIN data when it receives the last key (#) press after PIN code. Format: PIN Code ( any 4-8 digits between 0000-99999999) Example: PIN code:111111 Press 111111 #, then the output format will be: 0000111111 ( Note: if press an invalid PIN (any 4-8 digits), the data will be also transmitted.) To set Dur e ss card user To add a card user (The ID number is any number between 2001-2010) 2: Proximity Card Transmission The Reader will transmit the card data when it reads the Card. Format: Card Number (Note: No matter the card is valid or invalid, the data will be transmitted) 14.2 W3-H operating as a Controller In this mode the W3-H supports a Wiegand 26-37 bit input so an external Wiegand device with a 26-37 bit output can be connected to the Wiegand input terminals on the W3-H. Either an ID card reader (125KHz) or an IC card reader (13.56MHz) can be connected to the W3-H. Cards are required to be added at the external reader, except where an external HID reader is used, in this case cards can be added at either reader or controller. See figure 2. 13. Wiegand Mode Setting Special Power Supply DC 12V /3A GND W3-H supports Wiegand 26-37, both input and output. It can be used as a reader or controller. D0 D1 To set Wiegand format: 9 26-37 # (Default setting: Wiegand 26) ALARM- D_IN 14. Interconnecting Two Devices AC&DC AC&DC NO 14.1 W3-H operating as a Wiegand Output Reader Light and Sound Setting 7 4 # 7 5 # To set keypad backlight To disable keypad backlight To enable keypad backlight(Factory default) Keypad/Reader/Controller Transmission Format: OPEN Keypad Lockout W3-H Waterproof W3-H Note: ① User ID number must be any 4digits between 2001 - 2010 ② Duress PIN/card must be unique, should be distinguished from common PIN and card (When the Duress PIN/card is the same with common PIN and card, they will become invalid in Duress, and worked as common user function) Alarm output time AC&DC Black Figure 1 There are 10 groups Duress PIN/card available. When input Duress PIN/card, the door will open, at the same time, the output alarm operates. To set Duress PIN user To delete a card user To set card users by Manager card 1 User ID number # PIN # The ID number is any number between 1-2,000. The PIN is any 4-8 digits between 0000 - 99999999 with the exception of 1234 which is reserved. Users can be added continuously without exiting programming mode ALARM- Yellow 12. Duress User Settings Door Open Detection Door Open Too Long (DOTL) warning. When used with an optional magnetic contact or built-in magnetic contact of the lock, if the door is opened normally, but not closed after 1 minute, the inside buzzer will beep automatically to remind people to close the door and continue for 1 minute before switching off automatically. D1 Grey Red Power To delete a Card and PIN user just delete the card D0 White To remove the alarm To reset the Door Forced Open warning Toggle mode To disable the keypad tone To enable the keypad tone(Factory default) GND Green D0 D1 Pulse mode (Door relay time setting) To change a PIN in card and PIN mode (Method 2) Note that this is done out side programming mode so the user can undertake this themselves 7 6 # 7 7 # To set LED COM In this mode the W3-H supports a Wiegand 26-37 bit output so the Wiegand data lines can be connected to any controller which supports a Wiegand 26-37 bit input. See figure 1. NC Pink Wiegand reader Green COM NO +12V GND OPEN D0 White D1 Exit button Grey GND Yellow Brown NC Fail-Secure lock Fail-Secure lock V+ Door detecting switch Alarm Red Black Blue Purple Orange W3-H Figure 2 .7. .8. Rubber Bungs 6*27mm, used for fixing Self Tapping Screws 4*28mm, used for fixing Diode IN4004 Manager Card Manager Add Card & Manager Delete Card Please ensure that all the above contents are correct. If any are missing please notify the supplier of the W3-H. 2. Description The W3-H is a single door multifunction access control with HID card reader. It is suitable for mounting either indoor or outdoor in harsh environments. It is housed in a strong, sturdy and vandal proof zinc alloy electroplated case. The electronics are fully potted so the W3-H is waterproof and conforms to IP68. The W3-H supports up to 2,000 users in either a Card, 4-8 digits PIN, or a Card + PIN option and additional 10 groups Duress PIN/Card. The built-in card reader supports HID 125KHz frequency cards/tags. The W3-H has many extra features including Duress PIN/card, block enrollment, Wiegand 26-37 bits interface, and backlight keypad…etc. These features make W3-H an ideal choice for door access not only for small shops and domestic households but also for commercial and industrial applications such as factories, warehouses, laboratories, banks and prisons. 3. Features Waterproof, conforms to IP 68 Strong zinc alloy electroplated anti-vandal case Full programming from the keypad 2,000 users, supports Card, PIN, Card + PIN 10 groups Duress PIN/Card Card interface: HID 125KHz Card Can be used as a standalone keypad, PIN length 4-8 digits Pulse mode, Toggle mode Wiegand 26-37 input & output One programmable relay output, NO, NC, COM Adjustable door output time, alarm time, door open time Card block enrollment .1. NO NC COM AC&DC AC&DC OPEN D_IN ALARM- NC AC&DC NO COM D0 D1 GND D0 J1 D1 Anti-demolition alarm ALARMOPEN D_IN 4. Specifications Operating Voltage User Capacity 12-24V DC or 1 2 -18V AC 2,000 (Additional10 groups Duress PIN/Card) Keypad 12 keys: 3 X 4 digits Card Type HID 125KHz card Card Reading Distance 3-6 cm W3-H PCB connect diagram 6. Wiring AC&DC NO Colour Function Description Green D0 Wiegand Output D0 White D1 Wiegand Output D1 Alarm - Alarm Negative OPEN Request to Exit Button COM NC Active Current ≥65mA Grey Idle Current Lock Output Load ≥35mA Yellow Max 2A Brown Alarm Output Load Max 20A Red 12-24V DC or 12-18V AC 12-24V DC or 12-18V AC Regulated Power Input Operating Temperature -20-50 Black 12-24V DC or 12-18V AC 12-24V DC or 12-18V AC Regulated Power Input Operating Humidity 10%-90% RH Blue NO Relay NO Environment Adjustable Door Relay Time Conforms to IP68 Purple COM Relay COM Orange Relay NC Adjustable Alarm Time NC Wiegand Interface 0-3 minutes Wiegand 26-37 input & output Pink GND W3-H Negative Wiring Connections Electric Lock, Exit Button, DOTL, External Alarm Dimensions Net Weight L128 X W82 X H28mm 600 g Gross Weight 700 g 1-99 seconds D-IN GND D1 OPEN D_IN AC&DC AC&DC NO COM NC Alarm “ - ” White Grey Power Exit button Operation successful 12-24V DC or 12-18V AC/3A Operation failed Enter into programming mode In the programming mode Yellow Brown Door detecting switch Red Exit from the programming mode Black Open the door Alarm Purple Power“+” Electric bolt: NC Orange W3-H Electric strike: NO Lock Power DC 12V /3A Green Wiegand D0 White Wiegand D1 Grey Exit button NO +12V GND OPEN Fail-secure lock Yellow Brown COM Door detecting switch Alarm“-” Alarm Purple Orange Special Power Supply .3. Bright Bright Bright Short Ring Alarm To enter the programming mode Notes: Connect the negative pole of the lock to NC is for Fail safe lock. Connect the negative pole of the lock to NO is for Fail-secure lock. (This step must be done out of programming mode) To add a card user (Method 1) This is a fastest way to add cards using ID number auto generation To add a card user (Method 2) This is the optional way to add cards using User ID Allocation. In this method a User ID is allocated to a card. Only one user ID can be allocated to a single card * ID number # Old PIN # New PIN # New PIN # 1 Read Card Cards can be added continuously without exiting programming mode ID number # Card # To exit from the programming mode Note that to undertake the following programming the master user must be logged in To change the master code 0 New code # New code # The master code is any 6 digits Setting the working mode: set valid card only users set valid card and PIN users set valid card or PIN users 3 0 # Entry by Card only 3 1 # Entry by Card and PIN together 3 2 # Entry by either Card or PIN (default) To set a user in either card or PIN mode ( 3 2 # ) (Default setting) Every time a valid tag/card or PIN is read/input in Pulse Mode, the relay will operate, for the pre-set relay pulse time. To add a PIN user Every time a valid tag/card or PIN is read/input in Toggle Mode, the relay changes state, which will not turn back until read card or input PIN again. 9. To Reset to Factory Default Remarks: Reset to factory default, the user's information is still retained. .4. To delete a PIN user To add a card user (Method 3) Add a series cards users - Block Enrollment 5 ID number # The 1st Card number # Card quantity # Note that cards must be consecutive, and card quantity is between 1-2000 Maximum 2,000 cards can be enrolled at a stretch within 2 minutes To delete card user by card 2 Read Card * Master code # 888888 is the default factory master code The relay on board can operate in Pulse Mode (suitable for access control) or Toggle Mode (suitable for arming/disarming alarms, switching lights, machines….etc) To reset to factory default, power off, press * , hold it and power on, release it until hear two beeps and the LED shines in orange, then read any two HID cards, the LED will turn in red, means reset to factory default setting successfully. Of the two HID cards read, the first one is Manager Add Card, the second one is Manager Delete Card. Blue Buzzer Short Ring Short Ring Short Ring 3 Short Ring Short Ring Short Ring 11.1 User Settings Black Yellow Light Bright 11. W3-H Detailed Programming Guide Red Green Light Bright Common Power Supply The W3-H uses a LDR (light dependent resistor) as an anti tamper alarm. If the keypad is removed from the cover then the tamper alarm will operate. NC To change the PIN of a PIN user Red Light Bright Bright Bright Blue 7. Anti Tamper Alarm Pink W3-H .2. Power“+” Green Operation Status Power on Stand by Press keypad 8. Relay operation (Pulse mode and Toggle mode) ALARM- Remove the back cover from the keypad using the supplied security screwdriver Drill 4 holes on the wall for the screws and 1 hole for the cable Fix the back cover firmly on the wall with 4 flat head screws Thread the cable through the cable hole Attach the keypad to the back cover Door Contact Connection Giagram D0 5. Installation AC&DC Alarm Pink In4004 Screw Driver J1 D0 D1 User Manual GND Digital Keypad W3-H Remark D_IN AC&DC Quantity User Manual .10. 10. Sound and Light Indication ALARMOPEN Name With Manager Cards for adding or deleting card user easily Backlight keypad Built in light dependent resistor (LDR) for anti tamper Built in buzzer Red, Yellow and Green LED display the working status 12-24V DC or 12-18V AC Two-year warranty GND 1. Packing list .9. 1 User ID number # PIN # The ID number is any number between 12000. The PIN is any 4-8 digits between 0000 -99999999 with the exception of 1234 which is reserved. Users can be added continuously without exiting from programming mode as follows: 1 User ID No 1 # PIN # User ID No 2 # PIN # To delete a card user by user ID This option can be used when a user has lost their card 2 User ID # To delete a card user by card number 2 Card number # Users can be deleted continuously without exiting from programming mode To set a card and PIN user in card and PIN mode ( 3 1 # ) To Add a card and PIN user (The PIN is any 4-8 digits between 0000 - 99999999 with the exception of 1234 which is reserved) Add the card as for a card user Press * to exit from the programming mode Then allocate the card a PIN as follows: * Read Card 1234 # PIN # PIN # 2 User ID number # Users can be deleted continuously without exiting programming mode .5. Note users can be deleted continuously without exiting from programming mode .6. FCC WARNING This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE 1: Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No XMP Toolkit : 3.1-701 Creation Date--Text : Producer : Corel PDF Engine Version 14.0.0.653 Mod Date--Text : Trapped : False Format : application/pdf Creator : Administrator Title : W3-H 英文说明书印刷版修改12.cdr GTS PDFX Version : PDF/X-1:2001 GTS PDFX Conformance : PDF/X-1a:2001 Creator Tool : CorelDRAW Modify Date : 2012:03:15 15:57:09+08:00 Metadata Date : 2012:03:15 15:57:09+08:00 Document ID : uuid:b8e2d1ff-073c-46ed-b17a-db8715be5db4 Instance ID : uuid:984de416-a007-4b40-b6b8-8fef481c6c76 Page Count : 2 Create Date : D:20100315053615Z Author : AdministratorEXIF Metadata provided by EXIF.tools