Secukey Technology SK3 Wireless Access Control Kit User Manual Mini Control Board Sboard

Secukey Technology Co., Ltd. Wireless Access Control Kit Mini Control Board Sboard

User Manual

Download: Secukey Technology SK3 Wireless Access Control Kit User Manual Mini Control Board          Sboard
Mirror Download [FCC.gov]Secukey Technology SK3 Wireless Access Control Kit User Manual Mini Control Board          Sboard
Document ID3162121
Application IDpaQUeqEXeC7g14h/XLLowg==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize45.16kB (564518 bits)
Date Submitted2016-10-13 00:00:00
Date Available2016-10-13 00:00:00
Creation Date2016-09-23 17:11:39
Document Lastmod2016-09-23 17:11:39
Document TitleMini Control Board – Sboard
Document CreatorWPS Office
Document Author: Administrator

SK3-Ⅱ
Wireless Access Control
User Manual
INTRODUCTION
The SK3-Ⅱis a single door wireless access control, consists of a wireless keypad, a mini controller and a
wireless exit button. TEA + Rolling Code of encryption algorithm and the split design guarantees
higher-secure.
The keypad can store 500 PIN / card users. Because of ultra low power consumption, the keypad and the
exit button can work as long as one year (bases on 30 times/day), with just 3 units of AAA batteries and 1
unit Li-battery. It will remind people to replace batteries intelligently if low battery.
Features








500 PIN / card users
PIN length: 4~8 digits
125KHz EM card
Communication frequency: 2.4G
Communication distance: 15m Max
Pulse mode, toggle mode
Tri-color LED status display
Ultra low power consumption (wireless keypad≤10uA, Wireless Exit Button: ≤6uA)
Specifications
User Capacity
PIN Length
Card Type
Operating Voltage
Wireless Keypad
Mini Controller
Current
Idle Current
500
4~8 Digits
125KHz EM Card
3units of AAA batteries
12V DC ±20%
Communication Frequency
Wireless Keypad: ≤10uA
Mini Controller: ≤20uA
Wireless Keypad: ≤50mA;
Mini Controller: ≤40mA
2.4G
Communication Distance
15m Maximum
Relay Contact Load
Environment
Operating Temperature
Operating Humidity
Physical
Dimensions
2Amp Maximum
Indoor
-20℃~60℃ (-4℉~140℉)
0%~86%RH
ABS Shell
Wireless Keypad: L135 × W54 × D19(mm)
Mini Controller: L65 × W54 × D19(mm)
Wireless Keypad: 90g
Mini Controller: 40g
250g
Working Current
Unit Weight
Shipping Weight
Carton Inventory
Wireless Keypad
L135 × W54 × D19 (mm)
Mini Controller
L65 × W54 × D19 (mm)
Diode IN4004 (For relay circuit protection))
Self Tapping Screws: Φ3*25mm
Self Tapping Screws: Φ4*25mm
Wall Anchors
Screw Driver
Screw Driver
INSTALLATION
Method 1: Stick by 3M stickers
The device packed with 3M double-side Sticker, can easily stick the Wireless Keypad and Mini Controller on
Metal door, Glass Door, Wooden Door, or Smooth Wall.
Method 2: Install by screws
Sound and Light Indication
Operation Status
Red LED
Green LED
Buzzer
Standby
Unlock the lock
ON for 3 seconds
One beep
Key press under Program Mode
Shines per 1.5
seconds
One beep
One long
beep
Enter into Program Mode
Invalid PIN
Exit from the Program Mode
Low battery reminding (Keypad)
Low battery reminding (Exit button)
Orange LED ON
Shines from Red to Green twice
One beep
Three beeps
Connection Diagram
Access Control Power Supply:
Common Power Supply:
PROGRAMMING
Enter and Exit Program Mode
Programming Step
Keystroke Combination
1. Enter Program Mode
* (Master Code) #
(Factory default is 123456)
2. Exit
Set Master Code
Programming Step
Keystroke Combination
1. Enter Program Mode
* (Master Code) #
2. Update Master Code
0(New Master Code)#(Repeat New
Master Code)#
Master code is any 6 digits
3. Exit
Add User PIN(s)
User ID: 0~499
PIN length: 4~8 digits
Programming Step
Keystroke Combination
1. Enter Program Mode
* (Master Code) #
2. Add PIN
1 (User ID) # (PIN) # (Repeat PIN) #
The PINs can be added continuously
3. Exit
Add User Card(s)
User ID: 0~499
Card type: 125 KHz EM card
Programming Step
1. Enter Program Mode
2. Add Card: Using Auto ID
(Allows SK3-Ⅱto assign Card to next
available User ID number)
OR
2. Add Card: Select Specific ID
(Allows Master to define a specific User
ID to associate the card to)
3. Exit
Keystroke Combination
* (Master Code) #
1 (Read Card) #
The cards can be added continuously.
1 (User ID) # (Read Card) #
Change PIN Users
Programming Step
Keystroke Combination
Note: Below is done outside programming mode, users can undertake this themselves
2. Change PIN: By Card
* (Read Card) (Old PIN) # (New PIN) # (Repeat
(There will auto allocate PIN(8888) to
New PIN) #
cards when adding)
2. Change PIN: By PIN
* (User ID) # (Old PIN) # (New PIN) # (Repeat
New PIN) #
3. Exit
Exit automatically
Delete Users
Programming Step
Keystroke Combination
1. Enter Program Mode
* (Master Code) #
2. Delete user
2 (User ID) #
The users can be deleted continuously
OR
2. Delete Card
OR
2. Delete all users
3. Exit
2 (Read Card) #
2 (Master Code) #
Set Access Mode
Programming Step
Keystroke Combination
1. Enter Program Mode
* (Master Code) #
2. PIN Access
OR
PIN + Card Access
OR
PIN or Card Access
30#
3. Exit
31#
3 2 # (factory default)
Set Relay Configuration
The relay configuration sets the behavior of the output relay on activation.
Programming Step
Keystroke Combination
1. Enter Program Mode
* (Master Code) #
2. Pulse Mode
4 (1-99) # (factory default)
The relay time is 1-99 seconds. (1 is
OR
50mS.) (Default is 5 seconds)
2. Toggle Mode
3. Exit
40#
Set the relay to ON/OFF Toggle mode
Set Safety Mode
In safety mode, it can be set to deny access for 10 minutes after 10 failed PIN/card attempts in 10 minutes
(Factory default is OFF).
Programming Step
Keystroke Combination
1. Enter Program Mode
* (Master Code) #
2. Strike-Out OFF
6 0 # (factory default)
OR
2. Strike-Out ON
61#
3. Exit
Set Buzzer
Programming Step
1. Enter Program Mode
Keystroke Combination
* (Master Code) #
2. Buzzer OFF
OR
2. Buzzer ON
70#
3. Exit
7 1 # (factory default)
OTHERS
Users Operation
Programming Step
PIN User Access
Card User Access
PIN + Card User Access
Keystroke Combination
(PIN) #
# (Read Card)
# (Read Card) (PIN) #
Pair Wireless Keypad / Exit Button and Mini Controller
1) They all are already paired when out of factory, if no problem, the users do not need to do this operation
in using.
2) One Mini Controller can be connected by five pcs of Wireless Keypad and Exit Button maximum.
To pair the Wireless Keypad and Mini Controller:
Wireless Keypad: * Master Code # 9 0 #
Mini Controller: Remove the back cover, and press the button “Pair”
If pair successfully, there will be one beep from both the controller and the keypad; if not, there will be three
short beeps, then please repeat the setting. The keypad does not need to be entered * for exit in this step.
To pair the Wireless Exit Button and Mini Controller:
Wireless Exit Button: Remove the back cover, and press the button “Pair”
Mini Controller: Remove the back cover, and press the button “Pair”
If pair successfully, there will be one beep from both the controller and the exit button; if not, there will be
three short beeps, then please repeat the setting.
Pair two pcs of Wireless Keypad and Mini Controller---Optional
(This is optional solution for users, the extra wireless keypad Does Not included in the packing list)
Wireless Keypad 1: * Master Code # 9 0 #
Wireless Keypad 2: * Master Code # 9 0 #
Mini Controller: Remove the back cover, and press the button “Pair”
If pair successfully, there will be one beep from both the controller and the keypads; if not, there will be three
short beeps, then please repeat the setting. The keypads does not need to be entered * for exit in this step.
Reset to Factory Default
Open the back cover of the wireless keypad, press the button “RST” on the main board, hold it for 5 seconds,
release it until hear a long beep, means reset to factory default successfully.
After that, all settings except the relay time will be back to factory defaults, the users’ information will still
be retained.
At the meanwhile, please pair the wireless keypad and wireless exit button with the mini controller again.
Low Battery Reminding
. With 3 pieces 3A(AAA) battery, the wireless keypad can work continuously for at least 1 year, basing 30
times PIN/card input a day.
If low battery of the wireless keypad, there will be 3 beeps when every key is pressed, and the LED will stay
in Orange, then please replace the batteries within one week.
. With 2023 lithium battery, the wireless exit button can work continuously for at least 1 year, basing 30 times
press a day.
If low battery of the wireless exit button, the LED will shine from Red to Green twice, please replace the
battery within one week.
FCC STATEMENT :
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired
operation.
Warning: Changes or modifications not expressly approved by the party responsible for compliance could
void the user's authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
SK3-Ⅱ- Simplified Instruction
Function description
Operation
Enter the Program Mode
* (123456) #
then you can do the programming
(123456 is the factory default master code)
0 (New Code) # (Repeat the New Code) #
(Code: 6 digits)
Change the Master Code
Add PIN User
1 (User ID) # (PIN) # (Repeat PIN) #
Add Card User
1 (Read Card)
Delete User
Exit from the Program Mode
2 (User ID) #
2 (Read Card)
How to release the door
PIN Access
PIN #
Card Access
# (Read Card)
PIN + Card Access
# (Read Card) (PIN) #
Note: there is a battery spacer inside the Wireless Exit Button, please take it off before operation.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : No
Page Count                      : 9
Author                          : Administrator
Comments                        : 
Company                         : 
Create Date                     : 2016:09:23 17:11:39+09:11
Creator                         : WPS Office
Modify Date                     : 2016:09:23 17:11:39+09:11
Producer                        : 
Source Modified                 : D:20160923171139+09'11'
Subject                         : 
Title                           : Mini Control Board – Sboard
Trapped                         : false
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AJWY-SK3

Navigation menu