Securitron R100H Installation Instructions R100 1H I 500 24050 20A

User Manual: Securitron R100H Installation Instructions Installation Instructions

Open the PDF directly: View PDF PDF.
Page Count: 6

DownloadSecuritron  R100H Installation Instructions R100-1H I 500-24050 20A
Open PDF In BrowserView PDF
R100H Reader
Installation Instructions

Securitron Magnalock Corp.
Phoenix, AZ
800.624.5625
www.securitron.com

Package Contents
Hub Mounting
Bracket

Aperio Hub

Reader

CR2 Battery

Screws

Hex
Wrench
Glue

Recommended Tools
Approved Credential:

Level

Optional Dress Cover: R100-DCA

i.e., iCLASS or Prox ID card

Pencil, wax pencil

Optional Clamping device

Product Specifications
Hub Power Requirement: 8-24VDC, 250mA

Wireless Frequency: 2.4 GHz, IEEE 802.15.4, using AES 128bit encryption

Lock Battery Type: CR2, providing 35,000 Cycles

FCC Part 15, Class B Compliant, Industry Canada, CE Compliant

Reader Operating Temperature: -40F (-40C) to 122 F (+50C)
Credentials Supported: 125kHz Proximity or 13.56MHz iCLASS credentials are supported depending on reader model.

For technical support please call 1-800-624-5625
System Overview
The R100 wireless reader installs in locations where wiring may be difficult or undesired for aesthetic reasons. The
R100 wireless reader connects to an access control system through the included communication hub. The
communication hub connects to the access control system with wiegand wiring typical of a wiegand reader.
When a credential card is presented to the reader the request for access is sent wirelessly to the communication
hub. The communication hub then communicates through wiegand wiring to the access control system where the
decision is made to grant or deny access.
When access is granted the access control system unlocks the locking device seperately.

Part Number 500-24050, Rev. A

©2013, Securitron, Inc.

1

Installation Steps
1. Locate and Mount the Hub

3. Insert Battery

2. Connect the Hub

4. Mount Unit

5. Reattach Cover

1. Choose the hub location
It is recommended that the hub be
mounted near the top of a wall or on
the ceiling to reduce potential for
interference.
For a stable and reliable radio link,
it is recommended that the hub is
located within fifty (50) feet of the
lock. A maximum of two interior
walls between the hub and lock is
recommended.

B
A

Recommended locations:
A: Wall Mount
B: Ceiling Mount
For a glass entryway the hub
should be located in the interior
lobby.
*Note the hub is not rated for use in plenum air spaces.

Part Number 500-24050, Rev. A

©2013, Securitron, Inc.

2

2. Mounting the Hub.
The included adapter plate can be used to mount the hub on a single or double gang box.

Mounting the Hub

3. Wiring the Hub.
The Aperio Hub connects to the Access Control system via Wiegand wiring. The hub
requires 8-24VDC power (250mA). The hub includes two form C relays that can be used to
transmit low battery signal and a tamper signal.

*Note: the Green LED and Red LED inputs control feedback that
will be displayed at the reader for approved access (Green) or
denied access (Red).

Part Number 500-24050, Rev. A

©2013, Securitron, Inc.

Wiring the hub

3

4. Preparing the R100
Before starting, we recommend using a level to mark the position. Hold the reader body on the
outside of the window and position it generally where you would like it to mount.
Use a pencil to mark this
point on the window

Pull the cover up while pressing on the LED

5. Insert Battery
Install the battery, ensure correct orientation. The reader will self test and beep once.
Battery

6. Mounting the Unit The R100 can be mounted using glue or wood screws based on your needs.
6a. Apply Glue
It is recommended that a thin thread of glue is applied to three sides of the back-plate as shown. This
allows oxygen to enter and aid in the curing process. Do not use tissue or a brush to spread the
adhesive.
Quickly affix to the pre-marked area and hold or clamp until the adhesive has bonded (at least five
seconds) The seal becomes functional within a short time and permanent after 24- 72 hours.

Glue line

Position mark

Note the rate of cure depends on the ambient relative humidity. The best results are achieved when
the relative humidity in the working environment is 40-60% at 22˚C. Lower humidity leads to a
slower cure. High humidity accelerates it, but may impair the final strength of the bond.
Part Number 500-24050, Rev. A

©2013, Securitron, Inc.

4

6b. Mounting with wood screws
This is an alternate method for mounting the R100 to your door.
Separate the components by gripping the electronic module at the noted side areas. Rock up, pull
down, and lift out.

Wood screws
Mounting
Plate
Side grip
areas

Pre-drill through the mounting plate at the four corners and insert wood screws.
Reattach electronic module by sliding the top under the mounting plate’s raised edges and pressing
down firmly until it clicks.

7. Test Reader
Reattach cover and insert screw with the included hex wrench.
Use a credential known to the access control system to confirm it will read as desired. A green LED
indicates access is granted. Refer to the LED reference card for any other codes.
Cover

Screw

9. Optional: Attach Dress Cover
A separately purchased dress cover (R100-DCA) can be installed on the inside of a glass mounting
surface. Peel the backing from the adhesive on the cover and affix to the window.

R100
(rear view)

Dress Cover

Part Number 500-24050, Rev. A

©2013, Securitron, Inc.

5

WARNING
FCC Statement
This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment
generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:



Reorient or relocate the receiving antenna.



Increase the separation between the equipment and receiver.



Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.



Consult the dealer or an experienced radio/TV technician for help.

Operation with non-approved equipment is likely to result in interference to radio and TV reception. The user is cautioned that
changes and modifications made to the equipment without the approval of manufacturer could void the user’s authority to operate
this equipment.
IC Statement
This device complies with Industry Canada license-exempt RSS standards(s).
Operation is subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation.
Conformité aux normes FCC
Cet équipement a été testé et trouvé conforme aux limites pour un dispositif numérique de classe B, conformément à la Partie 15
des règlements de la FCC. Ces limites sont conçues pour fournir une protection raisonnable contre les interférences nuisibles dans
une installation résidentielle. Cet équipement génère, utilise et peut émettre des fréquences radio et, s'il n'est pas installé et utilisé
conformément ment aux instructions du fabricant, peut causer des interferences nuisibles aux communications radio. Rien ne
garantit cependant que l'interférence ne se produira pas dans une installation particulière. Si cet équipement provoque des
interférences nuisibles à la réception radio ou de télévision, qui peut être déterminé en comparant et en l'éteignant, l'utilisateur est
encouragé à essayer de corriger les interférence par une ou plusieurs des mesures suivantes:


Réorienter ou déplacer l'antenne de réception.



Augmenter la distance entre l'équipement et le récepteur.



Branchez l'appareil dans une prise sur un circuit différent de celui auquel le récepteur est connecté.



Consultez votre revendeur ou un technicien radio / TV pour assistance.Avertissement

Les changements ou modififications à cet appareil sans expressément approuvée par la partie responsable de conformité pourraient
annuler l'autorité de l'utilisateur de faire fonctionner cet équipement.
Conformité aux normes IC
Cet appareil est confrome avec Industrie Canada exempt de license RSS standard(s).
Son fonctionnement est souimes aux deux conditions suivantes:
(1) cet appareil ne peut causer d’interférences, et
(2) cet appareil doit accepter toute interference, y compris des interférences qui peuvent provoquer un fonctionnement indésirable
du périphérique.

For Technical Support please call 1-800-624-5625
Part Number 500-24050, Rev. A

©2013, Securitron, Inc.

6



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 6
Language                        : en-US
Producer                        : Microsoft® Office Word 2007
Creator                         : Microsoft® Office Word 2007
Create Date                     : 2013:10:03 14:28:57-07:00
Modify Date                     : 2013:10:03 14:28:57-07:00
EXIF Metadata provided by EXIF.tools

Navigation menu