Securitron WT2 Wiring And Use Instructions WTMN3A I 500 24060

User Manual: Securitron WT2 Wiring and Use Instructions Installation Instructions

Open the PDF directly: View PDF PDF.
Page Count: 4

DownloadSecuritron  WT2 Wiring And Use Instructions WTMN3A I 500-24060
Open PDF In BrowserView PDF
WT2 Wiegand Test Unit : Wiring and Use Instructions
FOR INSTALLATION ASSISTANCE, CALL 1-800-810-WIRE

CONTENTS

 WT2, plastic, 6.25” x 3.5” x 2.375”
 AC / DC adapter
 ElectroLynx cable with Molex connectors for Integrated Wiegand products
 ElectroLynx cable with Molex connector for NAC function EcoFlex electrified mortise locks
As part of their promise to provide innovative, fast and effective, and higher security solutions to their customers,
ASSA ABLOY Group companies offer ElectroLynx, a universal quick-connect system that simplifies the electrification
of the door opening. ElectroLynx™ is a trademark of ASSA ABLOY, Inc.

TEST BOX PRODUCT
DESCRIPTION

Designed for compatibility with ASSA ABLOY Integrated
Wiegand products and NAC Function EcoFlex mortise locks, the
ASSA ABLOY WT2 Wiegand Test Unit is a user-friendly tool that
demonstrates products features and capabilities.

6

The WT2 also enables field trouble shooting by verifying proper wiring,
card reader data integrity, lock functionality including: lock/unlock, door
position status, deadbolt status and REX (request-to-exit) status.
If end-of-line resistors are integrated into the product or wired into the
system, the WT2 will display these values.
If the WT2 detects line resistance above 100-Ohm on the REX or door
position sensing inputs, the unit will also display these resistance values.
Connect the WT2 directly to the lock or hinge using the provided
ElectroLynx cable.

End View

Adapter
7

5
6
1

Selectors,
Switches and Visual
Monitoring
Indicators

1
2
3
4
5
6

IMPORTANT

2

4

3

Fail Safe /Fail Secure Selector
Open Override
Learn Button
12VDC / 24VDC Selector
To Lock
To Power Adapter

7 LEDs refer to the following product features:

DPS Door position monitoring
RX Request to exit monitoring
TMPR Tamper
PWR ON Indicates unit powered
DX Deadbolt monitoring

1. Disconnect the product to be tested from access
control system before servicing.
2. Installer must be a trained, experienced
service person.
3. Wiring must comply with applicable local electrical
codes, ordinances and regulations.

INSTALLATION
INSTRUCTIONS

4. Unit is grounded to Common (-) for Electrostatic
Discharge (ESD) protection. Use appropriate ESD
practices when handling the unit, (i.e. standard
grounding precautions). Common (-) must be
grounded to earth (EG) at the power supply.
5. Ensure that no wires are pinched or
damaged during installation.

Install product on door according to manufacturer’s instructions, which can be found at
www.intelligentopenings.com or the following:
 SARGENT: www.sargentlock.com

 Corbin Russwin: www.corbinrusswin.com

 Securitron: www.securitron.com

 Yale: www.yalecommercial.com

 HES: www.hesinnovations.com
WTMN3A – PAGE 1

Copyright © 2015, ASSA ABLOY Inc. All rights reserved. Reproduction in whole or in part
without the express written permission of ASSA ABLOY Inc. is prohibited.

WT2 Wiegand Test Unit : Wiring and Use Instructions
CONNECT THE WT2

The WT2 is provided with two cables:
• The cable labeled ”Integrated Wiegand Locks Only” must be used with Integrated Wiegand locks.
• The cable labeled ” NAC Locks Only” must be used with NAC locks.

Lock to
WT2 Connections

Lock

ElectroLynx
Cable

Hinge with
ElectroLynx Cable

Pin Connections
to WT2

INTEGRATED WIEGAND
1 (Black) READER NEG
2 (Red) READER POS
3 (White) DATA 1
4 (Green) DATA 0
5 (Orange) RX (NO/NC)
6 (Blue) RX (COM)
7 (Brown) Not Used
8 (Yellow) LED
9 (Violet) LOCK NEG
10 (Gray) LOCK POS
11 (Pink) DPS NC
12 (Tan) DPS (COM)

NAC FUNCTION
1 Black (-)
2 Red (+)
3 White (DPS)
4 Green (DPS)
5 Orange (RX)
6 Blue (RX)
1 Violet (DX)
2 Gray (DX)

Important

ElectroLynx connectors plug
and lock together in only
one way, as shown. Do NOT
force connectors together.
Reference ElectroLynx
Catalog A7738.

Locking Mechanism
PIN 2
PIN 4
PIN 6
PIN 8

Receptacle

Plug

PIN 7
PIN 5
PIN 3
PIN 1

PIN 4 Tan (DPS)
PIN 2 (not used)

Copyright © 2015, ASSA ABLOY Inc. All rights reserved. Reproduction in whole or in part
without the express written permission of ASSA ABLOY Inc. is prohibited.
WTMN3A – PAGE 2

PIN 2 (not used)
PIN 3 Pink (DPS)

WT2 Wiegand Test Unit : Wiring and Use Instructions

Power Input

AC 100 – 240V 600mA 50Hz/60Hz

Power Output

The WT2 is capable of supplying a total of 900 MA output to the unit under test.
The 900 MA is the total output for both reader interface and the lock.

OPERATING
INSTRUCTIONS
FOR ALL CARDS

To initialize the test box for all cards:
1. Connect all wires to the WT2 first.
2. Select Fail Safe or Fail Secure according to sample.
3. Select the appropriate solenoid lock voltage (12 or 24 VDC).
4. Apply power to the WT2.
5. Once the door device completes its visual and audio signaling, it will
unlock when ANY Wiegand card is presented.

OPERATING
INSTRUCTIONS
FOR LIMITED
NUMBER OF CARDS

To initialize the test box for a limited number of specific cards:
1. Connect all wires to the WT2 first.
2. Select Fail Safe or Fail Secure according to sample.
3. Select the appropriate solenoid lock voltage (12 or 24 VDC).
4. Apply power to the WT2.
5. Press and hold the Learn button.
6. Present a card to the lock.
7. That card is recognized and added to the list of cards that will unlock the
lock. Other cards will not work until each is presented while holding down
the learn button.

Notes

 Failure to connect the WT2 to the lock before applying power results in
false reads.
 The WT2 will accept any data from a Wiegand output and any bit structure such as
the press of a key on a keypad to trigger the lock relay.
 The WT2 is capable of remembering up to the last 6 learned (programmed)
cards, whether they are the same or different.
 Once single card/cards are recognized, the door device will no longer
operate by the presentation of any random card until it has been reset.
 To reset the device, cycle the power while holding the learn button until it
flashes three times. Any card will then activate the lock.
 The system is designed to be installation-friendly with ElectroLynx®
quick connectors.

Copyright ©2015, ASSA ABLOY Inc. All rights reserved. Reproduction in whole or in part
without the express written permission of ASSA ABLOY Inc. is prohibited.
WTMN3A– PAGE 3

WT2 Wiegand Test Unit : Wiring and Use Instructions
FOR INSTALLATION ASSISTANCE, CALL 1-800-810-WIRE

WT2
CREDENTIAL
INFORMATION
DISPLAY

The LCD display on the WT2 provides the following information:
• Measured DPS Output Resistance (if > 100-Ohm)
• Measured REX Output Resistance (if > 100-Ohm)
• Wiegand Bits Received
• Wiegand Data Received (Hexadecimal Format)
• Card Facility Code (for known HID formats)
• Card Number (for known HID formats)

APPENDIX
PIN #

DESCRIPTION

WIRE COLOR

WIRE HARNESS
(Wiring diagram on
following page)

ELYNX CABLE
(Wiring
diagram on
previous page)

MISCELLANEOUS COMMENTS

Ground

1

Reader Power -

2

Reader Power +

3

Wiegand Data 1

4

Wiegand Data 0

5

REX Switch NC/NO (Keeper Switch on Strike)

6

REX Switch COM (Keeper Switch on Strike)

Blue

Interface TS4

7

Beeper Control - Cylinder Switch

Brown

Not Used

Not Used

8

LED Control

Yellow

Not Used

8 PIN -8

+5 goes to ground to turn LED Green

9

Lock Power

Violet

Not Used

4 PIN -1

Ground

10

Lock Relay Out

Grey

Not Used

4 PIN -2

* Lock Power+

11

DPS Switch NC/NO

Pink

InterfaceTS4

4 PIN -3

LED on when switch closed

Black

Interface TS1

8 PIN -1

Red

Not Used

8 PIN -2

+12 VDC always

White

Interface TS4

8 PIN -3

+5 goes to ground for data 1 bit

Green

InterfaceTS4

8 PIN -4

+5 goes to ground for data 0 bit LED on when

Orange

Interface TS4

8 PIN -5

REX used or when Keeper closed

8 PIN -6

LED on when REX used or when Keeper closed

12

DPS Switch COM

Tan

Interface TS4

4 PIN -4

LED on when switch closed

13

Beeper Control

Brown

InterfaceTS4

Not Used

+5 to turn Beeper on

14

LED Control

Yellow

Interface TS4

Not Used

+5 to turn LED Green LED on when secure

15

Dead Bolt Switch NC/NO

White/Orange

AUX Board TS1 AUX-2

Not Used

(Dead Bolt extended)

16

Latch Bolt Switch NC/NO

White/Red

AUX Board TS1 AUX-1

Not Used

** LED on when secure (Latch Bolt extended)

17

Cylinder Switch NC/NO - Spare

White/Black

Not Used

Not Used

LED on when Key in use (future)

18

Tamper Relay NC/NO

White/Blue

Interface TS1

Not Used

LED on when Tamper true

19

Lock Power + / Controller Power

Red

Interface TS1

Not Used

Switch selected 12VDC or 24VDC

20

Lock Relay IN

Violet

Lock Relay TS4

Not Used

* Lock Control

Copyright © 2015, ASSA ABLOY Inc. All rights reserved. Reproduction in whole or in part
without the express written permission of ASSA ABLOY Inc. is prohibited.
WTMN3A – PAGE 4



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.6-c067 79.157747, 2015/03/30-23:40:42
Create Date                     : 2015:07:20 08:26:14-04:00
Metadata Date                   : 2015:07:20 08:26:17-04:00
Modify Date                     : 2015:07:20 08:26:17-04:00
Creator Tool                    : Adobe InDesign CC 2015 (Windows)
Instance ID                     : uuid:4138171c-45c8-4f29-b20e-d3f5639474aa
Original Document ID            : xmp.did:e8601288-588e-e84c-bfeb-bb9d73cc4af8
Document ID                     : xmp.id:55df3e51-b160-404e-8af8-c5bae3db4b0a
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:3a873cd1-ca01-4243-a9ca-6809776fd5e5
Derived From Document ID        : xmp.did:3a873cd1-ca01-4243-a9ca-6809776fd5e5
Derived From Original Document ID: xmp.did:e8601288-588e-e84c-bfeb-bb9d73cc4af8
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 2015 (Windows)
History Changed                 : /
History When                    : 2015:07:20 08:26:15-04:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
Page Count                      : 4
Creator                         : Adobe InDesign CC 2015 (Windows)
EXIF Metadata provided by EXIF.tools