Securitron WT2 Wiring And Use Instructions WTMN3A I 500 24060
User Manual: Securitron WT2 Wiring and Use Instructions Installation Instructions
Open the PDF directly: View PDF
.
Page Count: 4
| Download | |
| Open PDF In Browser | View PDF |
WT2 Wiegand Test Unit : Wiring and Use Instructions FOR INSTALLATION ASSISTANCE, CALL 1-800-810-WIRE CONTENTS WT2, plastic, 6.25” x 3.5” x 2.375” AC / DC adapter ElectroLynx cable with Molex connectors for Integrated Wiegand products ElectroLynx cable with Molex connector for NAC function EcoFlex electrified mortise locks As part of their promise to provide innovative, fast and effective, and higher security solutions to their customers, ASSA ABLOY Group companies offer ElectroLynx, a universal quick-connect system that simplifies the electrification of the door opening. ElectroLynx™ is a trademark of ASSA ABLOY, Inc. TEST BOX PRODUCT DESCRIPTION Designed for compatibility with ASSA ABLOY Integrated Wiegand products and NAC Function EcoFlex mortise locks, the ASSA ABLOY WT2 Wiegand Test Unit is a user-friendly tool that demonstrates products features and capabilities. 6 The WT2 also enables field trouble shooting by verifying proper wiring, card reader data integrity, lock functionality including: lock/unlock, door position status, deadbolt status and REX (request-to-exit) status. If end-of-line resistors are integrated into the product or wired into the system, the WT2 will display these values. If the WT2 detects line resistance above 100-Ohm on the REX or door position sensing inputs, the unit will also display these resistance values. Connect the WT2 directly to the lock or hinge using the provided ElectroLynx cable. End View Adapter 7 5 6 1 Selectors, Switches and Visual Monitoring Indicators 1 2 3 4 5 6 IMPORTANT 2 4 3 Fail Safe /Fail Secure Selector Open Override Learn Button 12VDC / 24VDC Selector To Lock To Power Adapter 7 LEDs refer to the following product features: DPS Door position monitoring RX Request to exit monitoring TMPR Tamper PWR ON Indicates unit powered DX Deadbolt monitoring 1. Disconnect the product to be tested from access control system before servicing. 2. Installer must be a trained, experienced service person. 3. Wiring must comply with applicable local electrical codes, ordinances and regulations. INSTALLATION INSTRUCTIONS 4. Unit is grounded to Common (-) for Electrostatic Discharge (ESD) protection. Use appropriate ESD practices when handling the unit, (i.e. standard grounding precautions). Common (-) must be grounded to earth (EG) at the power supply. 5. Ensure that no wires are pinched or damaged during installation. Install product on door according to manufacturer’s instructions, which can be found at www.intelligentopenings.com or the following: SARGENT: www.sargentlock.com Corbin Russwin: www.corbinrusswin.com Securitron: www.securitron.com Yale: www.yalecommercial.com HES: www.hesinnovations.com WTMN3A – PAGE 1 Copyright © 2015, ASSA ABLOY Inc. All rights reserved. Reproduction in whole or in part without the express written permission of ASSA ABLOY Inc. is prohibited. WT2 Wiegand Test Unit : Wiring and Use Instructions CONNECT THE WT2 The WT2 is provided with two cables: • The cable labeled ”Integrated Wiegand Locks Only” must be used with Integrated Wiegand locks. • The cable labeled ” NAC Locks Only” must be used with NAC locks. Lock to WT2 Connections Lock ElectroLynx Cable Hinge with ElectroLynx Cable Pin Connections to WT2 INTEGRATED WIEGAND 1 (Black) READER NEG 2 (Red) READER POS 3 (White) DATA 1 4 (Green) DATA 0 5 (Orange) RX (NO/NC) 6 (Blue) RX (COM) 7 (Brown) Not Used 8 (Yellow) LED 9 (Violet) LOCK NEG 10 (Gray) LOCK POS 11 (Pink) DPS NC 12 (Tan) DPS (COM) NAC FUNCTION 1 Black (-) 2 Red (+) 3 White (DPS) 4 Green (DPS) 5 Orange (RX) 6 Blue (RX) 1 Violet (DX) 2 Gray (DX) Important ElectroLynx connectors plug and lock together in only one way, as shown. Do NOT force connectors together. Reference ElectroLynx Catalog A7738. Locking Mechanism PIN 2 PIN 4 PIN 6 PIN 8 Receptacle Plug PIN 7 PIN 5 PIN 3 PIN 1 PIN 4 Tan (DPS) PIN 2 (not used) Copyright © 2015, ASSA ABLOY Inc. All rights reserved. Reproduction in whole or in part without the express written permission of ASSA ABLOY Inc. is prohibited. WTMN3A – PAGE 2 PIN 2 (not used) PIN 3 Pink (DPS) WT2 Wiegand Test Unit : Wiring and Use Instructions Power Input AC 100 – 240V 600mA 50Hz/60Hz Power Output The WT2 is capable of supplying a total of 900 MA output to the unit under test. The 900 MA is the total output for both reader interface and the lock. OPERATING INSTRUCTIONS FOR ALL CARDS To initialize the test box for all cards: 1. Connect all wires to the WT2 first. 2. Select Fail Safe or Fail Secure according to sample. 3. Select the appropriate solenoid lock voltage (12 or 24 VDC). 4. Apply power to the WT2. 5. Once the door device completes its visual and audio signaling, it will unlock when ANY Wiegand card is presented. OPERATING INSTRUCTIONS FOR LIMITED NUMBER OF CARDS To initialize the test box for a limited number of specific cards: 1. Connect all wires to the WT2 first. 2. Select Fail Safe or Fail Secure according to sample. 3. Select the appropriate solenoid lock voltage (12 or 24 VDC). 4. Apply power to the WT2. 5. Press and hold the Learn button. 6. Present a card to the lock. 7. That card is recognized and added to the list of cards that will unlock the lock. Other cards will not work until each is presented while holding down the learn button. Notes Failure to connect the WT2 to the lock before applying power results in false reads. The WT2 will accept any data from a Wiegand output and any bit structure such as the press of a key on a keypad to trigger the lock relay. The WT2 is capable of remembering up to the last 6 learned (programmed) cards, whether they are the same or different. Once single card/cards are recognized, the door device will no longer operate by the presentation of any random card until it has been reset. To reset the device, cycle the power while holding the learn button until it flashes three times. Any card will then activate the lock. The system is designed to be installation-friendly with ElectroLynx® quick connectors. Copyright ©2015, ASSA ABLOY Inc. All rights reserved. Reproduction in whole or in part without the express written permission of ASSA ABLOY Inc. is prohibited. WTMN3A– PAGE 3 WT2 Wiegand Test Unit : Wiring and Use Instructions FOR INSTALLATION ASSISTANCE, CALL 1-800-810-WIRE WT2 CREDENTIAL INFORMATION DISPLAY The LCD display on the WT2 provides the following information: • Measured DPS Output Resistance (if > 100-Ohm) • Measured REX Output Resistance (if > 100-Ohm) • Wiegand Bits Received • Wiegand Data Received (Hexadecimal Format) • Card Facility Code (for known HID formats) • Card Number (for known HID formats) APPENDIX PIN # DESCRIPTION WIRE COLOR WIRE HARNESS (Wiring diagram on following page) ELYNX CABLE (Wiring diagram on previous page) MISCELLANEOUS COMMENTS Ground 1 Reader Power - 2 Reader Power + 3 Wiegand Data 1 4 Wiegand Data 0 5 REX Switch NC/NO (Keeper Switch on Strike) 6 REX Switch COM (Keeper Switch on Strike) Blue Interface TS4 7 Beeper Control - Cylinder Switch Brown Not Used Not Used 8 LED Control Yellow Not Used 8 PIN -8 +5 goes to ground to turn LED Green 9 Lock Power Violet Not Used 4 PIN -1 Ground 10 Lock Relay Out Grey Not Used 4 PIN -2 * Lock Power+ 11 DPS Switch NC/NO Pink InterfaceTS4 4 PIN -3 LED on when switch closed Black Interface TS1 8 PIN -1 Red Not Used 8 PIN -2 +12 VDC always White Interface TS4 8 PIN -3 +5 goes to ground for data 1 bit Green InterfaceTS4 8 PIN -4 +5 goes to ground for data 0 bit LED on when Orange Interface TS4 8 PIN -5 REX used or when Keeper closed 8 PIN -6 LED on when REX used or when Keeper closed 12 DPS Switch COM Tan Interface TS4 4 PIN -4 LED on when switch closed 13 Beeper Control Brown InterfaceTS4 Not Used +5 to turn Beeper on 14 LED Control Yellow Interface TS4 Not Used +5 to turn LED Green LED on when secure 15 Dead Bolt Switch NC/NO White/Orange AUX Board TS1 AUX-2 Not Used (Dead Bolt extended) 16 Latch Bolt Switch NC/NO White/Red AUX Board TS1 AUX-1 Not Used ** LED on when secure (Latch Bolt extended) 17 Cylinder Switch NC/NO - Spare White/Black Not Used Not Used LED on when Key in use (future) 18 Tamper Relay NC/NO White/Blue Interface TS1 Not Used LED on when Tamper true 19 Lock Power + / Controller Power Red Interface TS1 Not Used Switch selected 12VDC or 24VDC 20 Lock Relay IN Violet Lock Relay TS4 Not Used * Lock Control Copyright © 2015, ASSA ABLOY Inc. All rights reserved. Reproduction in whole or in part without the express written permission of ASSA ABLOY Inc. is prohibited. WTMN3A – PAGE 4
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : Adobe XMP Core 5.6-c067 79.157747, 2015/03/30-23:40:42 Create Date : 2015:07:20 08:26:14-04:00 Metadata Date : 2015:07:20 08:26:17-04:00 Modify Date : 2015:07:20 08:26:17-04:00 Creator Tool : Adobe InDesign CC 2015 (Windows) Instance ID : uuid:4138171c-45c8-4f29-b20e-d3f5639474aa Original Document ID : xmp.did:e8601288-588e-e84c-bfeb-bb9d73cc4af8 Document ID : xmp.id:55df3e51-b160-404e-8af8-c5bae3db4b0a Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:3a873cd1-ca01-4243-a9ca-6809776fd5e5 Derived From Document ID : xmp.did:3a873cd1-ca01-4243-a9ca-6809776fd5e5 Derived From Original Document ID: xmp.did:e8601288-588e-e84c-bfeb-bb9d73cc4af8 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 2015 (Windows) History Changed : / History When : 2015:07:20 08:26:15-04:00 Format : application/pdf Producer : Adobe PDF Library 15.0 Trapped : False Page Count : 4 Creator : Adobe InDesign CC 2015 (Windows)EXIF Metadata provided by EXIF.tools