Sengled E12N1X element classic User Manual

Sengled Co.,Ltd. element classic

User Manual

Download: Sengled E12N1X element classic User Manual
Mirror Download [FCC.gov]Sengled E12N1X element classic User Manual
Document ID3229008
Application IDsQHtzlBfVBTIabK3PFxBfA==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize167.8kB (2097538 bits)
Date Submitted2016-12-15 00:00:00
Date Available2016-12-15 00:00:00
Creation Date2016-12-11 14:40:33
Producing SoftwareMicrosoft® Office Word 2007
Document Lastmod2016-12-13 12:10:33
Document TitleUser Manual
Document CreatorMicrosoft® Office Word 2007
Document Author: 董爱荣

E12-N13- Wireless LED Bulb
E12-N13- Wireless LED Bulb
Z02-Hub –Sengled Hub
Element Bulb Specification
•Model: E12-N13
•Input: 100-130V AC, 60Hz, 85mA
•Power: 9.0W
•Brightness: 800 lumens
•CRI: >80
•Beam Angle: 110°
•Light Socket: E26
•Operating Temperature: -4 °F ~ + 104 °F (-20 °C ~ + 40 °C)
•Storage Temperature: -40 °F ~ + 158 °F (-40 °C ~ +70 °C)
•Operating Humidity: 10% ≤ RH ≤ 95%, non-condensing
•Dimensions: Dia: 5.1in (130mm); H: 3.7in (95mm)
Element Hub Specification
•Model: Z02-hub
•Input: 5V DC, 300mA
•Adapter Input: 100-240V AC, 30mA; Output: 5V DC, 1A
• Dimensions: L: 78mm; W: 78mm; H: 26mm
•Support Zigbee HA 1.2.1 and 2.4GHz Wi-Fi
Box Contents
•Two Element Classic BR30 Bulbs and One Hub
•One Ethernet Cable
•One welcome card
•Quick Start Guide
•Limited Written Express Warranty
NOT FOR EMERGENCY LIGHTING
This product is intended for indoor use only
Use in Dry Locations only
E12-N14- Wireless LED Bulb
E12-N14- Wireless LED Bulb
Z02-Hub –Sengled Hub
Element Bulb Specification
•Model: E12-N14
•Input: 100-130V AC, 60Hz, 85mA
•Power: 9.0W
•Brightness: 650 lumens
•CRI: >90
•Beam Angle: 110°
•Light Socket: E26
•Operating Temperature: -4 °F ~ + 104 °F (-20 °C ~ + 40 °C)
•Storage Temperature: -40 °F ~ + 158 °F (-40 °C ~ +70 °C)
•Operating Humidity: 10% ≤ RH ≤ 95%, non-condensing
•Dimensions: Dia: 5.1in (130mm); H: 3.7in (95mm)
Element Hub Specification
•Model: Z02-hub
•Input: 5V DC, 300mA
•Adapter Input: 100-240V AC, 30mA; Output: 5V DC, 1A
• Dimensions: L: 78mm; W: 78mm; H: 26mm
•Support Zigbee HA 1.2.1 and 2.4GHz Wi-Fi
Box Contents
•Two Element Classic BR30 Bulbs and One Hub
•One Ethernet Cable
•One welcome card
•Quick Start Guide
•Limited Written Express Warranty
NOT FOR EMERGENCY LIGHTING
This product is intended for indoor use only
Use in Dry Locations only
E12-N15- Wireless LED Bulb
E12-N15- Wireless LED Bulb
Z02-Hub –Sengled Hub
• Support for daylight white 5000K color temperature
Element Bulb Specification
•Model: E12-N15
•Input: 100-130V AC, 60Hz, 85mA
•Power: 9.0W
•Brightness: 800 lumens
•CRI: >80
•Beam Angle: 110°
•Light Socket: E26
•Operating Temperature: -4 °F ~ + 104 °F (-20 °C ~ + 40 °C)
•Storage Temperature: -40 °F ~ + 158 °F (-40 °C ~ +70 °C)
•Operating Humidity: 10% ≤ RH ≤ 95%, non-condensing
•Dimensions: Dia: 5.1in (130mm); H: 3.7in (95mm)
Element Hub Specification
•Model: Z02-hub
•Input: 5V DC, 300mA
•Adapter Input: 100-240V AC, 30mA; Output: 5V DC, 1A
• Dimensions: L: 78mm; W: 78mm; H: 26mm
•Support Zigbee HA 1.2.1 and 2.4GHz Wi-Fi
Box Contents
•Two Element Classic BR30 Bulbs and One Hub
•One Ethernet Cable
•One welcome card
•Quick Start Guide
•Limited Written Express Warranty
NOT FOR EMERGENCY LIGHTING
This product is intended for indoor use only
Use in Dry Locations only
Industry Canada (IC)
CAN ICES-3 (B)/NMB-3(B)
This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired
operation.
Cet appareil est conforme à la norme RSS d'Industrie Canada. Son fonctionnementestsujet aux deux
conditions suivantes:
(1) ledispositif ne doit pas produire de brouillagepréjudiciable, et
(2) cedispositifdoit accepter tout brouillagereçu, y compris un brouillage susceptible de provoquer un
fonctionnementindésirable.
IMPORTANT NOTE:
Radiation Exposure Statement:
This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This
equipment should be installed and operated with minimum distance 20cm between the radiator and your
body.
Déclarationd'exposition aux radiations:
Cetéquipementestconforme aux limitesd'exposition aux rayonnements IC établies pour un environnement
non contrôlé. Cetéquipementdoitêtreinstallé et utilisé avec un minimum de 20cm de distance entre la
source de rayonnement et votre corps.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Warning                         : Invalid secondary xref table
Page Count                      : 17
Language                        : zh-CN
Tagged PDF                      : Yes
Author                          : 董爱荣
Creator                         : Microsoft® Office Word 2007
Create Date                     : 2016:12:11 14:40:33
Modify Date                     : 2016:12:13 12:10:33+08:00
Producer                        : Microsoft® Office Word 2007
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AGN8-E12N1X

Navigation menu