Sensus Metering Systems 510R2 Utility Meter Transceiver User Manual amr 321

Sensus Metering Systems Utility Meter Transceiver amr 321

User Manual

Download: Sensus Metering Systems 510R2 Utility Meter Transceiver User Manual amr 321
Mirror Download [FCC.gov]Sensus Metering Systems 510R2 Utility Meter Transceiver User Manual amr 321
Document ID728118
Application IDGtmgKEKd7/WSbqTFZw3qxw==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize28.2kB (352539 bits)
Date Submitted2006-11-14 00:00:00
Date Available2006-11-14 00:00:00
Creation Date1995-08-30 15:55:32
Producing SoftwareAcrobat Distiller 4.0 for Macintosh
Document Lastmod2006-10-30 12:35:50
Document Titleamr_321.fm
Document CreatorFrameMaker 6.0
Document Author: Joseph Small

amr_321.fm Page 1 Tuesday, July 18, 2006 3:55 PM
AMR-XXX
Installation Instructions-Draft
Sensus RadioRead
Model 510R2 – Non Pit Unit
3. Place the unit over the TouchPad and press firmly until secure.
Important
The following information contains installation instructions for the
Sensus Model 510R2 MXU.
Note:
This installation sheet is only for installation of the Sensus
Model 510R2. For instructions on installing other AMR devices,
please request and refer to the individual installation instruction for those devices.
General Information
The Model 510R2 MXU is designed for non pit, non submersible
applications and is available for both a single port and dual port
operation. The Model 510R2 can be mounted indoors or outdoors
where it is not subject to submergence. The Model 510R2 is not
intended for outdoor meter pits or vaults. The unit can be installed
with either a TouchCoupler connection or wire connection. Please
refer to AMR-326 for compatibility.
4. For additional support (optional), open the MXU door and predrill the holes designed to fasten the unit to the wall. (Fastener
holes are located above the battery).
Definitions
5. Secure the unit to the wall with screws.
6. Once unit is secured with the screws, close the door of the
MXU and tighten security screw until unit is firmly sealed.
7. Once the unit is closed and secured, begin the activation
process. (See Activate Radio section).
8. Coil excess wire and then secure to the body of the meter or
service line in a presentable manner.
1. Sensus TouchPad
2. TouchPad Cover Assembly Complete
3. TouchPad Cover
4. TouchPad Fastener
5. TouchPad Cover Locking Clip
6. Model 510R2 Radio (Front View)
7. Model 5102 Radio TouchCoupler Enabled Assembly
(Rear View with TouchPad Cover)
TouchCoupler - Installation Instructions
Single Port – TouchCoupler Installation
1. Perform a TouchRead on TouchPad(s) to insure TouchRead to
the encoder works.
2. Taking a completely assembled Model 5102 Radio and TouchCoupler Spacer with TouchPad Cover, align the TouchPad
Cover over an installed Sensus TouchPad.
Single Port - Remote TouchCoupler
Installation
Remote TouchCoupler installations are an option when a direct
TouchCoupler (Sensus only) connection cannot be completed due
to physical limitations. Before proceeding with the installation of a
remote TouchCoupler application, be sure to find a location free
from obstacles that would interfere with the connection from the
TouchPad Cover to the MXU.
Recommended Tools and Materials
●
●
●
●
●
Wire stripping tool
Screwdriver - Small standard head for terminal connections
SR II security screw socket with 1/4" nut driver or ratchet wrench
Power drill and bit (1/4")
8 x 1" sheet metal screws
1. Find a suitable location for the installation where the TouchPad
Cover and MXU installation will be free from interference.
Note: If TouchPad is not already installed, install TouchPad allowing
enough room for the TouchPad Cover to be securely placed over
the installed TouchPad.
Page 1 of 4
amr_321.fm Page 2 Tuesday, July 18, 2006 3:55 PM
AMR-XXX
Installation Instructions-Draft
Sensus RadioRead
Model 510R2 – Non Pit Unit
2. Perform a TouchRead on TouchPad(s) to insure TouchRead to
the encoder works.
3. Place the remote TouchPad Cover firmly over the Sensus
TouchPad until secured.
4. Once the TouchPad Cover is secured on the TouchPad, find a
location close to the TouchPad Cover to install the MXU.
5. Place the MXU at the location for installation, with the door open,
mark the location to pre-drill the holes designed to fasten the
unit to the wall. (Fastener holes are located above the battery).
Dual Port – TouchCoupler Installation
Recommended Tools and Materials
●
●
●
●
●
6. Remove the MXU from the wall and use a 1/4" drill bit to pre-drill
the fastener holes.
7. Place the unit on the wall and align the pre-drilled holes with the
fastener locations.
8. Secure the unit to the wall with screws.
9. Connect the wires from the TouchPad Cover to the coordinating
port terminals in the MXU labeled TouchCoupled.
Note: Red and black wires are non-polarized.
Black
Black
Green
Touch
Coupled
PORT 1
Red
Red
Blue
BATTERY
Green
Black &
White
Sensus Metering Systems Uniontown, PA 15401
Model 510R Pt. No. 539-61-537-51006T
RadioRead M510R-D2-CMB-CMB-T
Patent Pending. Date 06/05
Touch
Coupled
PORT 2
Wire stripping tool
Screwdriver - Small standard head for terminal connections
SR II security screw socket with 1/4" nut driver or ratchet wrench
Power drill and bit (1/4")
8 x 1" sheet metal screws
1. Perform a TouchRead on TouchPad(s) to insure TouchRead to
the encoder works.
2. For new installations of dual ports, find a suitable location for an
installation where two TouchPads can be installed that will be free
from interference. The optimum distance should be less than 12"
otherwise wires may require field splicing. (For existing TouchPad
connections and second port is added, select a location for the
second TouchPad installation that will be free from interference).
3. Determine which of the two TouchPads will use the TouchPad
Cover only and which will use the TouchCoupler unit as the primary connection.
Note: If TouchPad is not already installed, install TouchPad allowing
enough room for the TouchPad Cover to be securely placed over
the installed TouchPad.
4. Place the remote TouchPad Cover firmly over the Sensus TouchPad until secured.
10. Once all the connections are complete, close the door of the
MXU and tighten security screw until unit is firmly sealed.
11. Once the units are secured, begin the activation process. (See
Activate Radio section).
5. With the MXU door open, place the MXU over the second TouchPad location and press firmly until unit is secured to the TouchPad. For additional support (optional), pre-drill the holes
designed to fasten the unit to the wall. (Fastener holes are
located above the battery). Secure the unit to the wall with
screws.
Note: If not already installed, install the second TouchPad allowing
enough room to connect the MXU to the TouchPad.
Page 2 of 4
amr_321.fm Page 3 Tuesday, July 18, 2006 3:55 PM
AMR-XXX
Sensus RadioRead
Installation Instructions-Draft
Model 510R2 – Non Pit Unit
Note:
Note: Red and black wires are non-polarized.
7.
Black
Green
Touch
Coupled
PORT 1
Red
Black
Blue
BATTERY
PORT 2
Red
Sensus Metering Systems Uniontown, PA 15401
Model 510R Pt. No. 539-61-537-51006T
RadioRead M510R-D2-CMB-CMB-T
Patent Pending. Date 06/05
Touch
Coupled
Green
Black
Green
Touch
Coupled
PORT 1
Red
Black
Red
Blue
BATTERY
Green
Black &
White
Sensus Metering Systems Uniontown, PA 15401
Model 510R Pt. No. 539-61-537-51006T
RadioRead M510R-D2-CMB-CMB-T
Patent Pending. Date 06/05
For the Neptune ProRead encoder, the color coded wire
connections are not standard – For ProRead, connect the MXU red
to ProRead black, MXU green to ProRead red, and MXU black to
ProRead green.
Black &
White
6. Connect the wires from the TouchPad Cover to the coordinating
port terminals in the MXU labeled TouchCoupled.
Touch
Coupled
PORT 2
Once all the connections are complete, close the door of the
MXU and tighten security screw until unit is firmly sealed.
8. Once the unit is closed and secured, begin the activation process. (See Activate Radio section).
7. Once all terminal connections are complete, close the door of the
MXU and tighten security screw until unit is firmly sealed.
8. Once the unit is closed and secured, begin the activation process. (See Activate Radio section).
Activate Radio
Note:
Single and Dual Port – Wired Installation
1. Place the MXU at the location for installation, with the door open,
mark the location to pre-drill the holes designed to fasten the unit
to the wall. (Fastener holes are located above the battery).
2. Remove the MXU from the wall and use a 1/4" drill bit to pre-drill
the fastener holes.
if encoders or multiread modules are not connected to this radio,
the radio will not activate.
Once all meters are connected, the radio must be activated in order
for it to perform its function. To activate, using a TouchReader or
Model 4090 AutoGun, perform a TouchRead on the Programming/
TouchRead port (See picture below). To use TouchReader+ to activate, follow instructions below. During activation process, the radio
will determine what is connected to this unit automatically. This may
take up to 3-6 seconds depending if the unit is dual port capable
and what type of encoders are connected.
Programming /
TouchRead
3. Place the unit on the wall and align the pre-drilled holes with the
fastener locations.
4. Secure the unit to the wall with screws.
5. Strip wires prior to inserting into terminal strip.
6. Connect the wires from the register to the coordinating port terminals in the MXU. Wire connections to terminal strip are red to red,
black to black, and green to green.
TouchReader+
1. If the TouchReader+ is not in Programmer Mode, press both Up
and Down arrow simultaneously to cycle through the different
modes.
Page 3 of 4
amr_321.fm Page 4 Tuesday, July 18, 2006 3:55 PM
AMR-XXX
Installation Instructions-Draft
Sensus RadioRead
Model 510R2 – Non Pit Unit
2. Once in Programmer Mode, pictured below, use the Up/Down
arrows until ENABLE is displayed.
3. Place the TouchReader+ Sensor on the Programming port of the
radio and press the Read button. This will send a message to
the radio to start the activation process. Keep TouchReader+ in
place until complete – messages will appear on the screen.
4. Once complete, the TouchReader+ will beep once upon success and display the radio’s status.
Deactivate Radio
TouchReader+
1. If the TouchReader+ is not in Programmer Mode, press both Up
and Down arrow simultaneously to cycle through the different
modes.
2. Once in Programmer Mode, pictured below, use the Up/Down
arrows until Deact is displayed.
If unsuccessful, the radio will remain in an idle state and the
TouchReader+ will beep twice and display the radio’s status.
3. Place the TouchReader+ Sensor on the Programming port of the
radio and press the Read button. This will send a message to the
radio to start the deactivation process. Keep TouchReader+ in
place until complete – messages will appear on the screen.
4. Once complete, the TouchReader+ will beep once upon success
and display the radio’s status.
TouchReader
1. The TouchReader will beep once indicating that the radio
acknowledged the TouchRead and is now detecting the type of
register connection.
2. After waiting approximately 3 seconds, perform another
TouchRead, if a read error occurs, the radio is still in detect
mode. Repeat this step again in 3 more seconds if read error
occurs.
3. If port detection is successful, the reading unit should provide
either a TouchRead reading (Sensus only) or a single beep to
indicate that the encoder is connected.
Note: TouchRead is not supported on Neptune registers.
AutoGun (ID type set to Factory ID – see AutoGun manual for
instructions)
1. The AutoGun will beep and display the ID with a “0” at the end.
This indicates that the radio acknowledged that TouchRead is
in inactive/idle mode "0". This will start the detecting process.
2. After waiting approximately 3 seconds, perform another
TouchRead, if a read error occurs, the radio is still in detect
mode. Repeat this step again in 3 more seconds.
3. If successful detection, the AutoGun will display either a
TouchRead reading (Sensus only) or
•
ID: 1 – which means a TouchRead was attempted on an
unsupported meter (Neptune).
•
ID: 2 – which means that the port was configured for a meter
type that supports TouchRead (Sensus only) but there was no
response from the meter.
4. If unsuccessful detection, the TouchRead will start the activation
process again. The ID on the AutoGun will display “0” similar to
the step 1 above.
Note:
If unsuccessful, the radio will remain in an active state and the
TouchReader+ will beep twice and display the radio’s status.
FCC Compliance
This equipment has been tested and found to comply with the limitations for a Class B digital device, pursuant to Part 15 of the FCC
rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and,
if not installed and used in accordance with these instructions, may
cause harmful interference to radio communications. However, there
is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio and
television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
● Reorient or relocate the receiving device
● Increase the separation between the equipment and receiver
● Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected
● Consult the dealer or an experienced radio/TC technician
Warning: No party shall make any modifications or changes to the
Sensus Model 510R2 MXU (the equipment) without express
written consent of Sensus Metering Systems. Doing so could
result in the equipment becoming non-compliant with the
requirements of the Federal Communications Commission
Rules CFR47 part 15 and could void the user’s authority to
operate the equipment.
Once the radio is activated and it detects the type of register connection, the only way to change its configuration to the correct
type of register connection is to deactivate the radio using a programming tool and then re-activate the radio or use a programming tool to reprogram the port manually.
AUTHORIZED SENSUS DISTRIBUTOR
P.O. Box 487 • 450 N. Gallatin Avenue
Uniontown, PA 15401
1-800-METER-IT • 1-800-638-3748
Fax: Direct to Factory
Local: 724-439-7729 • Toll Free: 1-800-888-2403
www.sensus.com (select "North America Water")
Email: h2oinfo@sensus.com
Page 4 of 4

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : 3.1-701
Create Date                     : 1995:08:30 15:55:32Z
Creator Tool                    : FrameMaker 6.0
Modify Date                     : 2006:10:30 12:35:50-07:00
Metadata Date                   : 2006:10:30 12:35:50-07:00
Format                          : application/pdf
Creator                         : Joseph Small
Title                           : amr_321.fm
Producer                        : Acrobat Distiller 4.0 for Macintosh
Document ID                     : uuid:12967b66-8f95-4601-b60d-27ae30dd4cbe
Instance ID                     : uuid:3ada9fdd-6856-11db-90ee-00145128619e
Page Count                      : 4
Author                          : Joseph Small
EXIF Metadata provided by EXIF.tools
FCC ID Filing: KCH510R2

Navigation menu