Sensys Gatso Netherlands RT3 RT3 Antenna User Manual RT3
Gatsometer BV RT3 Antenna RT3
Contents
- 1. Manual
- 2. Addendum
Manual
USER MANUAL DD-43-06 USER MANUAL RT3 VERSION: V1.0 Gatsometer BV Claes Tillyweg 2 2031 CW, Haarlem P.O. Box 4959 2003 EZ, Haarlem Tel.: +31 (0) 23 525 50 50 Fax: +31 (0) 23 527 69 61 Mail: info@gatsometer.com Internet: www.gatsometer.com 1/15 DISCLAIMER Copyright © 2013 - Gatsometer BV - The Netherlands None of the materials provided on this technical manual may be used, reproduced or transmitted in any form or by any means, electronic or mechanical, including recording or the use of any information storage and retrieval system, without written permission from Gatsometer BV. If you received this technical manual in error, please notify Gatsometer BV immediately. The confidential nature of and/ or privilege in the technical manual enclosed is not waived or lost as a result of a mistake or error in this technical manual. Gatsometer BV accepts no liability whatsoever, whether it was caused by: 1. Accessing or other related actions to this manual. 2. Actions other than stated in this user manual Gatsometer BV assumes that all users understand risks involved within this user manual and/ or its attached materials. All components used can be replaced by factory approved equivalents. Drawings are subject to change without prior notice. Translation disclaimer The translation of this documents is done with the utmost care. However, Gatsometer B.V. does not accept any liability for the correctness and completeness of the compilation and content of this translation and the direct or indirect consequences of acting or failing to act based on these translations. It is not possible to derive any rights, of whatever nature, from the compilation and contents of the translations. In all cases, the original English document shall be decisive. All rights reserved. Compiled by Gatsometer BV. Please contact info@gatsometer.com for more information. Gatsometer follows the ROHS (Restriction of Hazardous Substances 2002/95/EC) and WEEE (Waste Electrical and Electronic Equipment) directives. For the customers in Europe To comply with European directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE) this equipment must be recycled or disposed of properly. You can help preserve our environment by returning your used equipment to the distributor or the collection and recycling depot nearest to you. 2/15 FCC AND IC DECLARATIONS Compliance statement (part 15.19) This device complies with part 15 of the FCC Rules and to RSS210 of Industry Canada. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Warning (part 15.21) Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This in particular is applicable for the antenna which has been delivered with the RF Exposure (OET Bulletin 65) To comply with FCC RF exposure requirements for mobile transmitting devices, this transmitter should only be used or installed at locations where there is at least 20cm separation distance between the antenna and all persons. Information to the User (Part 15.105 (b)) Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: --Reorient or relocate the receiving antenna. --Increase the separation between the equipment and receiver. --Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. --Consult the dealer or an experienced radio/TV technician for help. 3/15 USER MANUAL RT3 VERSION: V1.0 Latest version is checked on 09 October 2013 REVISION REMARKS V0.9 V1.0 First release, DD-43-06 FCC disclaimer TABLE OF CONTENTS CHAPTER TITLE PAGE INTRODUCTION 1.1 General description of RT3 radar COMMAND SET 7\ 2.1 Set RF ON/OFF 2.2 Set Channel 1 2.3 Set Channel 2 10 2.4 Set Channel 3 11 2.5 Set Channel 4 12 POWER SUPPLY 13 3.1 Specifications 14 4/15 INTRODUCTION 5/15 The RT3 antenna is designed as measurement and detection unit for Gatso System solutions. This tracking radar operates in the K-band and uses modulation to detect range and speed to the several target in the radar beam. As part of a system, the RT3 is connected by one cable only. It provides both power and control from the system to the RT3. The control interface is designed on CANopen communication. The physical interface is performed by a CAN network. The system is in command over the radar and it will perform the RF settings when the system becomes operational. In this manual, both power supply and control set will be described in the following paragraphs. 6/15 COMMAND SET 7/15 Operational commands to control the RF section of the radar can be summarized into 2 functions: 1. Switch RF section ON / OFF 2. Set the frequency channel of the RF section Command ‘Switch RF section ON / OFF’ controls the RF transmitter output. When the system is operational, the RF is switched ON. During all other states, the RF is switched OFF. Command ‘Set frequency channel’ will select 1 of 4 available channels of the transmitter. In the section below, a photo of the spectrum analyzer show the signal when the RF is set to a channel. Note that only one of four channels is used during operation. Spectrum analyzer setting are visible in the photo’s. 8/15 Set channel 1: 9/15 Set channel 2: 10/15 Set channel 3: 11/15 Set channel 4: 12/15 POWER SUPPLY 13/15 All boards inside the RT2 have a dedicated voltage regulator for individual accurate supply voltages. Power supply specification for the RT3: RF OFF, 200 mA typ. @ 12 VDC RF ON, 235 mA typ. @ 12 VDC 14/15 USER MANUAL RT3 VERSION: V1.0 15/15
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 15 Language : en-US Tagged PDF : Yes Title : USER MANUAL RT3 Author : COMMAND SET Creator : Microsoft® Office Word 2007 Create Date : 2013:10:09 10:48:47+02:00 Modify Date : 2013:10:09 10:48:47+02:00 Producer : Microsoft® Office Word 2007EXIF Metadata provided by EXIF.tools