Sensys Networks FLEXRPS FLEX-RPT3-SLR-E User Manual Quick Start Guide FLEX Repeater
Sensys Networks, Inc. FLEX-RPT3-SLR-E Quick Start Guide FLEX Repeater
Quick Start Guide
Quick Start Guide: FlexRepeat3 Solar Repeater Assemble Warnings Lithium Batteries Sensys Networks uses Lithium Thionyl Chloride batteries in the following products: • SENSORS (VSN240-F-2/M-2/MP-2/T-2 series) • REPEATERS (RP240, FLEX-RP, and FLEX-RPT3 series (contains additional 18650 Li-Ion batteries)) Lithium batteries are widely used in electronic products because they contain more energy per unit-weight than conventional batteries. However, the same properties that deliver high energy density also contribute to potential hazards if the batteries are damaged. Improper use or handling of the batteries may result in leakage or release of battery contents, explosion, or fire. Following are the recommendations of the battery manufacturer for proper use and handling of batteries in the Sensys Networks devices mentioned above: FlexRepeat3 Solar Installation Parts A FlexRepeat3 Solar assembly requires a single FlexRepeat3 Solar and the mounting kit. • DO NOT CHARGE OR ATTEMPT TO RECHARGE THE BATTERIES • DO NOT CRUSH OR PUNCTURE BATTERIES • DO NOT SHORT-CIRCUIT THE BATTERIES • DO NOT FORCE OVER-DISCHARGE OF THE BATTERIES • DO NOT INCINERATE OR EXPOSE BATTERIES TO EXCESSIVE HEATING • DO NOT EXPOSE BATTERY CONTENTS TO WATER • DO DISPOSE OF BATTERIES AND DEVICES CONTAINING BATTERIES IN ACCORDANCE WITH LOCAL REGULATIONS Sensys Networks sensors contain no serviceable parts and should never be disassembled. Installation and removal of sensors from pavement should only be done by trained personnel and care should be taken to insure that the sensor casing is not punctured or crushed. Additional safety information is available from the battery’s manufacturer: • Sensor battery cell: http://sensysnetworks.com/sensorbattery • Repeater battery cell: http://sensysnetworks.com/ repeaterbattery 1608 4th Street Suite 200 Berkeley CA 94710 | www.sensysnetworks.com/resources| P 510.548.4620 F 510.548.8264 Quick Start Guide: FlexRepeat3 Solar Repeater Turn On Repeater Unscrew Power Jumper Cap Remove Red Jumper Unscrew the black cap to expose the red jumper and LED indicator. Remove the red jumper (a) and place the jumper on one pin (b). Wait approximately five seconds for LED light to blink red to ensure unit is turned on. After ensuring the unit is properly turned on, screw on the black cap. WARNING: DO NOT open repeater. Removing top could damage unit. Note: To turn off, return jumper to original position. For Use of External Antenna Only Unscrew the metal cap for the external antenna cable outlet (a) and discard (b). Note: If the FlexRepeat3 Solar is not used with a external antenna then do not remove cap. 1608 4th Street Suite 200 Berkeley CA 94710 | www.sensysnetworks.com/resources| P 510.548.4620 F 510.548.8264 Quick Start Guide: FlexRepeat3 Solar Repeater Mount FlexRepeat3 Solar on Pole Ensure at least one solar panel has access to the optimal available sunlight. Mount The FlexRepeat3 Solar Assemble the mounting kit onto the pole. Attach mounting arm to the mounting plate. Attach the FlexRepeat3 Solar to the mounting arm with the Towards Sensors side facing the sensors and access point or supporting repeater. Ensure the mounting arm is tightened so the repeater cannot move. Note that the mounting arm can be oriented to adjust the location of the FlexRepeat3 Solar. Connect External Antenna (Optional) Connect to one of the external antenna options with a coax cable. Two options are supported: (a) the FLEX-ANT-1 with the same RF range as the internal antenna and (b) the FLEX-ANT-2 with Long Range RF range. Point the external antenna towards the sensors. The roles of the internal and external antenna can also be switched. 1608 4th Street Suite 200 Berkeley CA 94710 | www.sensysnetworks.com/resources| P 510.548.4620 F 510.548.8264 Quick Start Guide: FlexRepeat3 Solar Repeater Connect to Access Point Requirements FlexRepeat3 Solar requires TrafficDOT2 software 2.12.12 or later. Run TrafficDOT Select IP address Click the icon to start TrafficDOT2. Select an access point from the list of APCCs and Access Points and click Connect. Note: Ensure the box for Load map data is checked before clicking Connect. Main Window The Main window displays. The map on the Main window populates and configured equipment appears on the map and in the sensor tray at the bottom of the window. 1608 4th Street Suite 200 Berkeley CA 94710 | www.sensysnetworks.com/resources| P 510.548.4620 F 510.548.8264 Quick Start Guide: FlexRepeat3 Solar Repeater Configure Repeater Channel Notes • The default radio channel for access point to repeater communications is 4. • The default radio channel for repeater to sensor communications is 5. • Never use the same channel for both access point and sensor communications. Refer to Sensys Network VDS240 Wireless Vehicle Detection System TrafficDOT Set Up and Operating Guide for more information. Config Notes Repeater Configuration Window Select a repeater from the image map or tray to access the Repeater Configuration window with the Info tab open. The Name field allows the repeater’s name to be user-defined. Specifying Upstream Channel Select an upstream channel by clicking the Config tab. Select an entry for the Current Upstream Ch field by clicking on the Change to drop-down list. Specifying Downstream Channel Select a entry for the Current Downstream Ch field by clicking the Change to drop-down list. Note: Repeater’s firmware version is displayed for reference only. 1608 4th Street Suite 200 Berkeley CA 94710 | www.sensysnetworks.com/resources| P 510.548.4620 F 510.548.8264 • When an installation contains multiple repeaters with more than 20 sensors, changing one or more repeaters from Current Config 0 to Current Config 1 allows the access point to communicate with up to 40 sensors through the repeaters. Refer to Sensys Network VDS240 Wireless Vehicle Detection System TrafficDOT Set Up and Operating Guide for more information. Quick Start Guide: FlexRepeat3 Solar Repeater Configure Repeater (cont.) Save Configuration Click Set Channel(s) to accept configuration changes. Specifying Time Slot Click the Auto-assign All button to automatically assign all Sensors and Repeaters to optimal timeslots. Note: The grayed out options can be made accessible by enabling Advanced Mode using the Advanced drop-down menu. To manually set the time slot, TrafficDOT filters the contents of the drop-down list so that only available time slots are displayed. Click an entry from the Change Timeslot to drop-down list and then click Set Timeslot to accept changes. To change the drop-down list to include all time slots in the network (both assigned and unassigned), remove the check in the Show only available slots. 1608 4th Street Suite 200 Berkeley CA 94710 | www.sensysnetworks.com/resources| P 510.548.4620 F 510.548.8264 Save Configuration Click SAVE to save changes made to the access point. Quick Start Guide: FlexRepeat3 Solar Repeater Configure Repeater (cont.) Adv Tab Notes • A failsafe error message occurs should you choose the external antenna option when there is no external antenna installed. • If FlexRepeat3 Solar is installed with or without the external antenna, and the Antenna panel options are left unchecked, the internal antenna is used for both To AP and To Sensors channels. • If Discover Mode is not ON the following warning will display: Advanced setting values shown are either not set or last known current value because discover not on. Value(s) will not be updated until discover turned on. • If Discover Mode is OFF at connection time for TrafficDOT the Adv tab displays Not Set values. Turn Discover Mode ON for true values to display. Refer to Sensys Network VDS240 Wireless Vehicle Detection System TrafficDOT Set Up and Operating Guide for more information. Adv Tab Solar Tab If the repeater is connected to an external antenna, then it can be configured via the Adv tab. From the Antenna panel, select either To AP or To Sensors to configure an internal/external antenna. Click the Solar tab to view the solar supply status. Click Apply to accept configuration changes. Click SAVE at the top of the screen to save changes made to the access point. Note: Recommended setting for external antenna is To Sensors. Local Distributor Sensys Networks and the Sensys Networks logo are trademarks of Sensys Networks, Inc. All other trademarks are the property of their respective owners. Information contained herein is believed to be reliable, but Sensys Networks makes no warranties as to its accuracy or completeness. Copyright © 2017 Sensys Networks, Inc. • ALL RIGHTS RESERVED • CONTENTS SUBJECT TO CHANGE
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Format : application/pdf Title : Quick Start Guide: FLEX Repeater Create Date : 2017:10:24 15:37:12-07:00 Metadata Date : 2017:10:24 15:41:46-07:00 Modify Date : 2017:10:24 15:41:46-07:00 Creator Tool : Adobe InDesign CS6 (Windows) Instance ID : uuid:6f5bcc55-090d-46e8-8096-379b3464cb7d Original Document ID : xmp.did:F77F1174072068118083FBAF5E674C88 Document ID : xmp.id:4E6C48D80BB9E711A0C0B1CB0E61701B Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:4D6C48D80BB9E711A0C0B1CB0E61701B Derived From Document ID : xmp.did:69A71C2253CCE1118E84874CA5B122FC Derived From Original Document ID: xmp.did:F77F1174072068118083FBAF5E674C88 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Windows) History Changed : / History When : 2017:10:24 15:37:12-07:00 Producer : Adobe PDF Library 10.0.1 Trapped : False Page Count : 7 Creator : Adobe InDesign CS6 (Windows)EXIF Metadata provided by EXIF.tools