Sensys Networks FLEXRPS FLEX-RPT3-SLR-E User Manual Quick Start Guide FLEX Repeater

Sensys Networks, Inc. FLEX-RPT3-SLR-E Quick Start Guide FLEX Repeater

Quick Start Guide

Download: Sensys Networks FLEXRPS FLEX-RPT3-SLR-E User Manual Quick Start Guide  FLEX Repeater
Mirror Download [FCC.gov]Sensys Networks FLEXRPS FLEX-RPT3-SLR-E User Manual Quick Start Guide  FLEX Repeater
Document ID3666203
Application ID2RIesuCdlfc1pDriaY9fmA==
Document DescriptionQuick Start Guide
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize182.55kB (2281855 bits)
Date Submitted2017-12-07 00:00:00
Date Available2017-12-07 00:00:00
Creation Date2017-10-24 15:37:12
Producing SoftwareAdobe PDF Library 10.0.1
Document Lastmod2017-10-24 15:41:46
Document TitleQuick Start Guide: FLEX Repeater
Document CreatorAdobe InDesign CS6 (Windows)

Quick Start Guide: FlexRepeat3 Solar Repeater
Assemble
Warnings
Lithium Batteries
Sensys Networks uses Lithium Thionyl Chloride batteries in the
following products:
• SENSORS (VSN240-F-2/M-2/MP-2/T-2 series)
• REPEATERS (RP240, FLEX-RP, and FLEX-RPT3 series
(contains additional 18650 Li-Ion batteries))
Lithium batteries are widely used in electronic products because they
contain more energy per unit-weight than conventional batteries.
However, the same properties that deliver high energy density
also contribute to potential hazards if the batteries are damaged.
Improper use or handling of the batteries may result in leakage or
release of battery contents, explosion, or fire.
Following are the recommendations of the battery manufacturer for
proper use and handling of batteries in the Sensys Networks devices
mentioned above:
FlexRepeat3 Solar Installation Parts
A FlexRepeat3 Solar assembly requires a single
FlexRepeat3 Solar and the mounting kit.
• DO NOT CHARGE OR ATTEMPT TO RECHARGE THE
BATTERIES
• DO NOT CRUSH OR PUNCTURE BATTERIES
• DO NOT SHORT-CIRCUIT THE BATTERIES
• DO NOT FORCE OVER-DISCHARGE OF THE BATTERIES
• DO NOT INCINERATE OR EXPOSE BATTERIES TO
EXCESSIVE HEATING
• DO NOT EXPOSE BATTERY CONTENTS TO WATER
• DO DISPOSE OF BATTERIES AND DEVICES CONTAINING
BATTERIES IN ACCORDANCE WITH LOCAL REGULATIONS
Sensys Networks sensors contain no serviceable parts and should
never be disassembled. Installation and removal of sensors from
pavement should only be done by trained personnel and care should
be taken to insure that the sensor casing is not punctured or crushed.
Additional safety information is available from the battery’s
manufacturer:
• Sensor battery cell: http://sensysnetworks.com/sensorbattery
• Repeater battery cell: http://sensysnetworks.com/
repeaterbattery
1608 4th Street Suite 200 Berkeley CA 94710 | www.sensysnetworks.com/resources| P 510.548.4620 F 510.548.8264
Quick Start Guide: FlexRepeat3 Solar Repeater
Turn On Repeater
Unscrew Power Jumper Cap
Remove Red Jumper
Unscrew the black cap to expose the red jumper and LED indicator.
Remove the red jumper (a) and place the jumper on one pin (b). Wait approximately
five seconds for LED light to blink red to ensure unit is turned on. After ensuring the
unit is properly turned on, screw on the black cap.
WARNING: DO NOT open repeater. Removing top could damage unit.
Note: To turn off, return jumper to original position.
For Use of External Antenna Only
Unscrew the metal cap for the external antenna cable outlet (a) and discard (b).
Note: If the FlexRepeat3 Solar is not used with a external antenna then do not remove cap.
1608 4th Street Suite 200 Berkeley CA 94710 | www.sensysnetworks.com/resources| P 510.548.4620 F 510.548.8264
Quick Start Guide: FlexRepeat3 Solar Repeater
Mount FlexRepeat3 Solar on Pole
Ensure at least one
solar panel has
access to the optimal
available sunlight.
Mount The FlexRepeat3 Solar
Assemble the mounting kit onto the pole. Attach mounting arm to the mounting plate. Attach the FlexRepeat3 Solar to the mounting
arm with the Towards Sensors side facing the sensors and access point or supporting repeater. Ensure the mounting arm is
tightened so the repeater cannot move. Note that the mounting arm can be oriented to adjust the location of the FlexRepeat3 Solar.
Connect External Antenna (Optional)
Connect to one of the external antenna options with a coax cable. Two options are supported: (a) the FLEX-ANT-1
with the same RF range as the internal antenna and (b) the FLEX-ANT-2 with Long Range RF range. Point the
external antenna towards the sensors. The roles of the internal and external antenna can also be switched.
1608 4th Street Suite 200 Berkeley CA 94710 | www.sensysnetworks.com/resources| P 510.548.4620 F 510.548.8264
Quick Start Guide: FlexRepeat3 Solar Repeater
Connect to Access Point
Requirements
FlexRepeat3 Solar requires
TrafficDOT2 software 2.12.12
or later.
Run TrafficDOT
Select IP address
Click the icon to start TrafficDOT2.
Select an access point from the list of APCCs
and Access Points and click Connect.
Note: Ensure the box for Load map data is
checked before clicking Connect.
Main Window
The Main window displays. The map on the Main window
populates and configured equipment appears on the map and
in the sensor tray at the bottom of the window.
1608 4th Street Suite 200 Berkeley CA 94710 | www.sensysnetworks.com/resources| P 510.548.4620 F 510.548.8264
Quick Start Guide: FlexRepeat3 Solar Repeater
Configure Repeater
Channel Notes
• The default radio channel
for access point to repeater
communications is 4.
• The default radio channel for
repeater to sensor communications
is 5.
• Never use the same channel for
both access point and sensor
communications.
Refer to Sensys Network VDS240
Wireless Vehicle Detection System
TrafficDOT Set Up and Operating
Guide for more information.
Config Notes
Repeater Configuration Window
Select a repeater from the image
map or tray to access the Repeater
Configuration window with the Info
tab open. The Name field allows the
repeater’s name to be user-defined.
Specifying Upstream Channel
Select an upstream channel by clicking
the Config tab. Select an entry for the
Current Upstream Ch field by clicking on
the Change to drop-down list.
Specifying Downstream Channel
Select a entry for the Current
Downstream Ch field by clicking
the Change to drop-down list.
Note: Repeater’s firmware version is
displayed for reference only.
1608 4th Street Suite 200 Berkeley CA 94710 | www.sensysnetworks.com/resources| P 510.548.4620 F 510.548.8264
• When an installation contains
multiple repeaters with more than
20 sensors, changing one or more
repeaters from Current Config 0 to
Current Config 1 allows the access
point to communicate with up to
40 sensors through the repeaters.
Refer to Sensys Network VDS240
Wireless Vehicle Detection System
TrafficDOT Set Up and Operating
Guide for more information.
Quick Start Guide: FlexRepeat3 Solar Repeater
Configure Repeater (cont.)
Save Configuration
Click Set Channel(s) to
accept configuration changes.
Specifying Time Slot
Click the Auto-assign All button to automatically assign all
Sensors and Repeaters to optimal timeslots.
Note: The grayed out options can be made accessible by enabling
Advanced Mode using the Advanced drop-down menu.
To manually set the time slot, TrafficDOT filters the contents of
the drop-down list so that only available time slots are displayed.
Click an entry from the Change Timeslot to drop-down list and
then click Set Timeslot to accept changes.
To change the drop-down list to include all time slots in the
network (both assigned and unassigned), remove the check in
the Show only available slots.
1608 4th Street Suite 200 Berkeley CA 94710 | www.sensysnetworks.com/resources| P 510.548.4620 F 510.548.8264
Save Configuration
Click SAVE to save changes
made to the access point.
Quick Start Guide: FlexRepeat3 Solar Repeater
Configure Repeater (cont.)
Adv Tab Notes
• A failsafe error message occurs should you
choose the external antenna option when there
is no external antenna installed.
• If FlexRepeat3 Solar is installed with or
without the external antenna, and the Antenna
panel options are left unchecked, the internal
antenna is used for both To AP and To Sensors
channels.
• If Discover Mode is not ON the following
warning will display: Advanced setting values
shown are either not set or last known current
value because discover not on. Value(s) will
not be updated until discover turned on.
• If Discover Mode is OFF at connection time
for TrafficDOT the Adv tab displays Not Set
values. Turn Discover Mode ON for true values
to display.
Refer to Sensys Network VDS240 Wireless
Vehicle Detection System TrafficDOT Set Up and
Operating Guide for more information.
Adv Tab
Solar Tab
If the repeater is connected to an external antenna, then it can be
configured via the Adv tab. From the Antenna panel, select either To
AP or To Sensors to configure an internal/external antenna.
Click the Solar tab to view the solar supply status.
Click Apply to accept configuration changes.
Click SAVE at the top of the screen to save changes made to the access
point.
Note: Recommended setting for external antenna is To Sensors.
Local Distributor
Sensys Networks and the Sensys Networks logo are trademarks of Sensys Networks, Inc. All other trademarks are the property of their respective owners.
Information contained herein is believed to be reliable, but Sensys Networks makes no warranties as to its accuracy or completeness.
Copyright © 2017 Sensys Networks, Inc. • ALL RIGHTS RESERVED • CONTENTS SUBJECT TO CHANGE

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Format                          : application/pdf
Title                           : Quick Start Guide: FLEX Repeater
Create Date                     : 2017:10:24 15:37:12-07:00
Metadata Date                   : 2017:10:24 15:41:46-07:00
Modify Date                     : 2017:10:24 15:41:46-07:00
Creator Tool                    : Adobe InDesign CS6 (Windows)
Instance ID                     : uuid:6f5bcc55-090d-46e8-8096-379b3464cb7d
Original Document ID            : xmp.did:F77F1174072068118083FBAF5E674C88
Document ID                     : xmp.id:4E6C48D80BB9E711A0C0B1CB0E61701B
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:4D6C48D80BB9E711A0C0B1CB0E61701B
Derived From Document ID        : xmp.did:69A71C2253CCE1118E84874CA5B122FC
Derived From Original Document ID: xmp.did:F77F1174072068118083FBAF5E674C88
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Windows)
History Changed                 : /
History When                    : 2017:10:24 15:37:12-07:00
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Count                      : 7
Creator                         : Adobe InDesign CS6 (Windows)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: TDB-FLEXRPS

Navigation menu