Rhein Tech Laboratories, Inc.
360 Herndon Parkway
Suite 1400
Herndon, VA 20170
http://www.rheintech.com
Appendix G:
Client:
Model:
Standard:
FCC ID:
Report #:
Sequel Technologies, LLC
STCP-STE
FCC 15.231
V4X-STEX01
2008068
Manual
Please see the following pages.
Page 26 of 39
ST Express / ST8 Security Systems
Document Number: 550-00008 Rev. A
User Manual
Copyright 2008
Sequel Technologies, LLC.
Contents
System Overview� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� 3
Control Panel �
�� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� 3
�� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� 3
Zones/Sensors� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� 3
Modules� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� 3
Keypad Layout�� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� 4
User Command Summary��� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� 5
Arming the System� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� 6
Arming the Perimeter� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� 6
Arming All��� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� 6
No Delay � �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� 6
Latchkey Feature � �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� 6
Bypassing Sensors��� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� 6
Disarming the System� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� 7
Wireless Keyfob Operation��� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� 7
Phone Control � �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� 8
Entry and Exit Delay��� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� 9
Chime Mode� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� 9
X10 Lights � �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� 9
Checking the Status � �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �10
Email Notification � �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �10
Alarm Conditions� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� � 11
Fire Alarms � �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� � 11
Police Alarms � �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� � 11
Activating a Panic Alarm from an LCD Keypad� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� � 11
Activating Alarms from your Wireless Keyfob��� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� � 11
Duress Alarm � �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� � 11
Siren Time-out��� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� � 11
Dialer Delay� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� � 12
System Alarm Responses� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� � 12
User Setup Mode � �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� � 13
Entering User Setup Mode � �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� � 13
User PINs � �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� � 13
Setting the Time and Date��� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� � 14
Connecting to the Remote Service Tool (RST)� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� � 14
Testing the System � �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �15
Test Command Summary� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� � 15
Walk Test � �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� � 15
Dialer Test� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� � 16
Wireless Sensor Batteries� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� � 16
Trouble Conditions� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� � 17
Silencing Trouble Beeps � �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� � 17
Keypads�
ii
System Overview
Congratulations on your ownership of an ST security system, which offers the latest in security protection technology. The ST system consists of a control panel, at least one keypad
and various sensors that provide burglary and/or fire protection. In addition, your system
may be programmed to send alarm and status messages to a central alarm monitoring station.
Control Panel
The control panel is the main processing unit for all system functions. It receives and responds
to signals from sensors throughout the premises. For monitored systems, the control panel connects to the premises phone line or an optional Ethernet module for central station reporting.
Keypads
LCD Keypad
The 2-line x 16 character LCD keypad allows control and programming of the security system
and displays system status messages.
Wireless Keyfob
The wireless keyfob allows users the ability to arm and disarm the system, turn lights
on/off (if programmed), and activate a panic alarm. The keyfob includes a 5 year userreplaceable battery.
Zones/Sensors
The system includes various detection devices, which are identified by the security system
as zones. Each zone has a type of detection sensor, which is installed throughout the premises to identify alarm conditions and communicate this information to the control panel.
The sensors used in the system may include, but are not limited to, devices such as door/
window sensors, smoke detectors, and motion sensors.
Door/Window Sensors
Door/Window sensors protect the perimeter of your home or business by alerting the control panel when a door or window is opened.
Smoke Detectors
Smoke and heat detectors protect the premises from fire conditions and remain active 24
hours per day regardless of the arming level of the system.
Motion Sensors
Motion sensors detect a person moving across the field of detection.
Modules
Optional modules may be included with your system to provide additional functionality.
Ethernet Interface Module
Your system may include an Ethernet Interface Module that provides Internet central station reporting, browser access, and email reporting to your PC or cell phone. In addition, a
third-party adapter (such as D-Link DWL-G810) can be used to allow the system to have
802.11 Wi-Fi capabilities.
Remote Audio Module (Included with the ST Express)
The Remote Audio Module provides voice feedback for system conditions. If your system is
monitored, the module gives the central station operator the ability to communicate with the
occupants on the premises during an alarm. The operator can then determine the appropriate
course of action and dispatch the proper assistance. Ask your installer if this feature is enabled.
External Transceiver Module (Included with the ST Express)
The External Transceiver Module provides bidirectional wireless communications to the
system’s wireless sensors.
ST User Manual
Keypad Layout
S1
S2
EXIT
S3
NEXT
10
POLICE
FIRE
Table 1: Functions of the LCD Keypad
1 - Number Pad
Used for entering PINs and system commands
2 - Arm All
Arms perimeter and interior burglary zones
3 - Disarm
Disarms the burglary portion of the system, and cancels alarms
4 - LCD Display
Displays system status, alarms, and user messages
5 - Armed Indicator
• If the Armed light is on, the system has been successfully armed in
the ALL or PERIMETER mode
• If the Armed light is flashing, the system has an active alarm condition
6 - Ready Indicator
• If the Ready light is on, the system is ready for arming
• If the Ready light is flashing, the system is not ready to be armed (a
zone is open)
7 -Trouble Indicator
If the Trouble light is on, the system has a trouble condition
8 - Function Keys
• S1, S2, S3 - Selects the menu item shown on the LCD above the key
• Exit - Press to exit the current menu
• Next - Press to proceed to the next item
9 - Arm Perimeter
Arms the perimeter burglary zones (i.e. exterior doors/windows).
Interior burglary zones (i.e. motion detectors) are not armed, which
allows movement within your residence without causing an alarm.
10 - Emergency Keys
These keys are used as Police and Fire panic keys. These keys may
not be enabled in all systems (ask your installer).
ST User Manual
User Command Summary
Action
LCD Keypad Command
System Operation
Disarm to Off / Cancel an Alarm
+ PIN Or Enter PIN
Arm Perimeter
+ PIN (if prompted)
Arm All
+ PIN (if prompted)
Arm with No Delay
Or + PIN +
Arm with Latchkey
Or + PIN + + Enter Latchkey Time
Turn Chime On/Off
ON: NEXT + +
OFF: NEXT + +
Turn All Lights On/Off (ST8 Only)
ON: NEXT + + +
OFF: NEXT + + +
Turn Individual Lights On/Off (ST8 ON: NEXT + + + Light # +
Only)
OFF: NEXT + + + Light # +
Alarms
Initiate a Police Alarm
Press and hold the POLICE button for two seconds
Initiate a Fire Alarm
Press and hold the FIRE button for two seconds
Initiate a Duress Alarm
Enter the four-digit Duress PIN to disarm the system
Programming
Enter User Setup Menu
Add a User PIN
NEXT + NEXT + NEXT + + User PIN
1.
2.
3.
4.
5.
Enter User Setup menu.
With the display showing PINS TIME DATE, select .
The display will show PINS TO EDIT: 01
Enter user number to add and select . (e.g. To add user 09, enter 09)
Enter new pin and select . To confirm, enter new pin again and press
twice.
Note: For security, existing PINs are never shown
Set the Time
1.
2.
3.
4.
Enter User Setup menu.
With the display showing PINS TIME DATE, select
Source Exif Data:
File Type : PDF
File Type Extension : pdf
MIME Type : application/pdf
PDF Version : 1.6
Linearized : No
XMP Toolkit : 3.1-702
Modify Date : 2008:07:15 10:33:14-07:00
Create Date : 2008:07:15 10:32:24-07:00
Metadata Date : 2008:07:15 10:33:14-07:00
Creator Tool : Acrobat PDFMaker 7.0.7 for Word
Format : application/pdf
Title : CERTIFICATE OF COMPLIANCE
Creator : Systems Administrator
Document ID : uuid:b6e3b1ae-d66d-47c7-9de3-52874260b5aa
Instance ID : uuid:3ae47919-e26c-43b3-a7d3-dbf5dae1d12b
Producer : Acrobat Distiller 7.0.5 (Windows)
Has XFA : No
Page Count : 20
Author : Systems Administrator