Sercomm SWDWS02N Z-Wave Door Window Sensor User Manual

Sercomm Corporation Z-Wave Door Window Sensor

User Manual.pdf

Download: Sercomm SWDWS02N Z-Wave Door Window Sensor User Manual
Mirror Download [FCC.gov]Sercomm SWDWS02N Z-Wave Door Window Sensor User Manual
Document ID2945774
Application ID25L0K49gtB3SQSCBV1DDxA==
Document DescriptionUser Manual.pdf
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize22.08kB (276034 bits)
Date Submitted2016-03-30 00:00:00
Date Available2016-03-30 00:00:00
Creation Date2016-03-22 14:52:27
Producing SoftwarepdfFactory Pro 3.51 (Windows 7 Ultimate Chinese (Traditional))
Document Lastmod2016-03-22 15:19:40
Document TitleUser Manual.pdf
Document CreatorpdfFactory Pro www.pdffactory.com
Document Author: 01318

SW-DWS02N Door/Window Sensor Installation Guide
Introduction
Z-Wave Door/Window sensors are designed to secure the perimeter of the residential premise, and provide the
ability to add various automation services. The Z-Wave Door/Window sensor, which consists of a magnet that
attaches to a door or window, will communicate door events to the home security system. When the magnet is
moved away from the sensor, a signal will be sent to the control panel that communicates the changed state to the
security system. Signals can also be used to activate a chime or convenience lighting based on system settings.
Specification
Frequency
Battery Type
Operating Temperature
Storage Temperature
Operating Air Range
Dimension
908.42 / 908.40 / 916.00 MHz
CR2 Battery 1 PCS
0° C to 50° C (32°F - 122°F)
-20° C to 60° C (-4°F - 140°F)
Up to 148 feet line of sight
Device: 67 mm x 19 mm x 20 mm (2.63" x 0.74" x 0.78")
Magnet: 45 mm x 8 mm x 15 mm (1.77" x 0.31" x 0.59")
Add (Inclusion) Sensor
For Adding in (Inclusion) a network: Put the Z-Wave Interface Controller into “Add (Inclusion)” mode, and
following its instruction to add SW-DWS02N to your controller. This Door/Window sensor needs to be included
before installation.
1.
Pull the exposed plastic tab from the sensor. (Figure 1)
Figure 1
2.
3.
The Green LED indicator will be lit for one second to indicate a successful booting.
It will blink one time every second while scanning the network (Figure 2).
Green LED Indictor
Figure 2
4.
If network is not found after 30 seconds, the sensor will go into sleep mode. To wake the sensor again, you
need to use magnet or tamper (Figure 3) to trigger a paring process, and then sensor will repeat steps from 3 to
4.
CR2 Battery
Tamper Switch
Figure 3
Remove (Exclusion) Sensor
Inclusion Sensor
For Removing from (Exclusion) a network: Put the Z-Wave Interface Controller into “Remove (Exclusion)” mode,
and following its instruction to delete SW-DWS02N to your Z-Wave controller.
1.
Remove device rear cover and pressing the tamper button three times within 2 seconds, green LED indicator
should go “On” 0.5 second and enter exclusion mode. (Figure 4).
Pressing the tamper button
Figure 4
2.
3.
If remove (exclusion) successful, go auto Adding procedure.
Node ID has been remove.
Factory Default Reset
Installation
1.
Pressing the tamper button four times within 2 seconds (Figure 4) and do not release the tamper button in the
4th pressed, and the LED will turn ON.
2. After over 3 seconds the Green LED indicator will turn OFF, then go auto Adding procedure.
3. IDs are excluded and all settings will reset to factory default.
4. Device begin auto Adding (Inclusion) mode.
Note: Use this procedure only in the event that the primary controller is lost.
Installation
Inclusion Sensor
1.
2.
Please make sure that the sensor and magnet is located less than 0.7 inch from each other. For optimal
performance, it is highly recommended to install the Door/Window sensor on the fixed frame and the magnet
on the moving part of the door/window. Place the sensor near the top of the door that close to the opening
edge of the door. This is the mounting location for the sensor.
Use the provided double-sided tape on the sensor. Attach the sensor to the door. Press firmly and hold in place
for a few seconds (Figure 5). Secure it with silicone if needed.
Figure 5
3.
Adhesive application surface: Acrylic, Glass
Aluminum and Stainless steel…etc.
Use provided double-sided tape on the magnet. Make sure the alignment of both sensor and magnet alignment
mark are facing each other (Figure 6). Press firmly and hold in place for a few seconds. Secure it with
silicone if needed.
Alignment Mark
Figure 6
4.
SW-DWS02N can be included and operated in any Z-Wave network with other Z-Wave certified devices
from other manufacturers and/or other applications. All non-battery operated nodes within the network will
act as repeaters regardless of vendor to increase reliability of the network.
5.
Association
Support grouping identifier = 1
Support one group with 5 nodes.
All triggering report and low voltage report will be sent to the associated nodes.
6.
Awake mode
It will be triggering after opening bottom cover. SW-DWS02N will send “Wake Up Notification” after 10
seconds. If SW-DWS02N received “Wake Up No More Information” command then will go off or it will
wait 10 seconds then go off. It will proceed all the commands after sending the “Wake Up Notification”.
7.
Auto Wake Up
Use “Wake up” command to set up the awaking time and send the wake up notification to controller.
User can use command to change the auto wake up from 1 minute to 24 hours, interval increment is 1
minute. Factory default is 120 minutes.
Z-Wave Command Classes
•
•
•
•
•
•
•
•
•
•
•
•
COMMAND_CLASS_ZWAVEPLUS_INFO
COMMAND_CLASS_VERSION
COMMAND_CLASS_MANUFACTURER_SPECIFIC
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_BATTERY
COMMAND_CLASS_NOTIFICATION
COMMAND_CLASS_ASSOCIATION
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_BASIC
COMMAND_CLASS_WAKE_UP
COMMAND_CLASS_FIRMWARE_UPDATE_MD
Notification Type
Notification Type
Event
BASIC Report
Alarm Type
Alarm Level
Switch Type
Reed Switch
Tamper Switch
Reed Switch
Status
0x06
0x07
Close:0x17, Open:0x16
Tamper Switch
Close:0x00, Open:0x03
Reed Switch
Reed Switch
Tamper Switch
Close:0x00, Open:0xFF
0x06
0x07
Close:0x00, Open:0xFF
Operation
1.
2.
3.
The Green Pairing LED will stay off during the normal operation.
The sensor is equipped with a tamper switch. If the cover of sensor is removed, the sensor will send an alarm
to the home controller.
Tamper switch event will be ignored when in auto inclusion procedure.
Certification
FCC Statement: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and,
if not installed and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
The FCC ID for this device is P27SWDWS02N
You are cautioned that changes or modifications not expressly approved by the party responsible for compliance
could void your authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation.
FCC RF Radiation Exposure Statement:
• This Transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
• This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This
equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and
your body.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Print, Copy, Extract
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Create Date                     : 2016:03:22 14:52:27+08:00
Creator Tool                    : pdfFactory Pro www.pdffactory.com
Modify Date                     : 2016:03:22 15:19:40+08:00
Metadata Date                   : 2016:03:22 15:19:40+08:00
Format                          : application/pdf
Creator                         : 01318
Title                           : SW-DWS02N QIG_20160319(EMI 要求更新頻率).docx
Producer                        : pdfFactory Pro 3.51 (Windows 7 Ultimate Chinese (Traditional))
Document ID                     : uuid:c5e03b35-7b0b-4a4e-b898-7dfb2583a036
Instance ID                     : uuid:b156239e-9bff-4af8-997d-5fbf94ee82bc
Page Count                      : 4
Page Layout                     : SinglePage
Author                          : 01318
EXIF Metadata provided by EXIF.tools
FCC ID Filing: P27SWDWS02N

Navigation menu