SW-DWS02N Door/Window Sensor Installation Guide Introduction Z-Wave Door/Window sensors are designed to secure the perimeter of the residential premise, and provide the ability to add various automation services. The Z-Wave Door/Window sensor, which consists of a magnet that attaches to a door or window, will communicate door events to the home security system. When the magnet is moved away from the sensor, a signal will be sent to the control panel that communicates the changed state to the security system. Signals can also be used to activate a chime or convenience lighting based on system settings. Specification Frequency Battery Type Operating Temperature Storage Temperature Operating Air Range Dimension 908.42 / 908.40 / 916.00 MHz CR2 Battery 1 PCS 0° C to 50° C (32°F - 122°F) -20° C to 60° C (-4°F - 140°F) Up to 148 feet line of sight Device: 67 mm x 19 mm x 20 mm (2.63" x 0.74" x 0.78") Magnet: 45 mm x 8 mm x 15 mm (1.77" x 0.31" x 0.59") Add (Inclusion) Sensor For Adding in (Inclusion) a network: Put the Z-Wave Interface Controller into “Add (Inclusion)” mode, and following its instruction to add SW-DWS02N to your controller. This Door/Window sensor needs to be included before installation. 1. Pull the exposed plastic tab from the sensor. (Figure 1) Figure 1 2. 3. The Green LED indicator will be lit for one second to indicate a successful booting. It will blink one time every second while scanning the network (Figure 2). Green LED Indictor Figure 2 4. If network is not found after 30 seconds, the sensor will go into sleep mode. To wake the sensor again, you need to use magnet or tamper (Figure 3) to trigger a paring process, and then sensor will repeat steps from 3 to 4. CR2 Battery Tamper Switch Figure 3 Remove (Exclusion) Sensor Inclusion Sensor For Removing from (Exclusion) a network: Put the Z-Wave Interface Controller into “Remove (Exclusion)” mode, and following its instruction to delete SW-DWS02N to your Z-Wave controller. 1. Remove device rear cover and pressing the tamper button three times within 2 seconds, green LED indicator should go “On” 0.5 second and enter exclusion mode. (Figure 4). Pressing the tamper button Figure 4 2. 3. If remove (exclusion) successful, go auto Adding procedure. Node ID has been remove. Factory Default Reset Installation 1. Pressing the tamper button four times within 2 seconds (Figure 4) and do not release the tamper button in the 4th pressed, and the LED will turn ON. 2. After over 3 seconds the Green LED indicator will turn OFF, then go auto Adding procedure. 3. IDs are excluded and all settings will reset to factory default. 4. Device begin auto Adding (Inclusion) mode. Note: Use this procedure only in the event that the primary controller is lost. Installation Inclusion Sensor 1. 2. Please make sure that the sensor and magnet is located less than 0.7 inch from each other. For optimal performance, it is highly recommended to install the Door/Window sensor on the fixed frame and the magnet on the moving part of the door/window. Place the sensor near the top of the door that close to the opening edge of the door. This is the mounting location for the sensor. Use the provided double-sided tape on the sensor. Attach the sensor to the door. Press firmly and hold in place for a few seconds (Figure 5). Secure it with silicone if needed. Figure 5 3. Adhesive application surface: Acrylic, Glass Aluminum and Stainless steel…etc. Use provided double-sided tape on the magnet. Make sure the alignment of both sensor and magnet alignment mark are facing each other (Figure 6). Press firmly and hold in place for a few seconds. Secure it with silicone if needed. Alignment Mark Figure 6 4. SW-DWS02N can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. 5. Association Support grouping identifier = 1 Support one group with 5 nodes. All triggering report and low voltage report will be sent to the associated nodes. 6. Awake mode It will be triggering after opening bottom cover. SW-DWS02N will send “Wake Up Notification” after 10 seconds. If SW-DWS02N received “Wake Up No More Information” command then will go off or it will wait 10 seconds then go off. It will proceed all the commands after sending the “Wake Up Notification”. 7. Auto Wake Up Use “Wake up” command to set up the awaking time and send the wake up notification to controller. User can use command to change the auto wake up from 1 minute to 24 hours, interval increment is 1 minute. Factory default is 120 minutes. Z-Wave Command Classes • • • • • • • • • • • • COMMAND_CLASS_ZWAVEPLUS_INFO COMMAND_CLASS_VERSION COMMAND_CLASS_MANUFACTURER_SPECIFIC COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_BATTERY COMMAND_CLASS_NOTIFICATION COMMAND_CLASS_ASSOCIATION COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_BASIC COMMAND_CLASS_WAKE_UP COMMAND_CLASS_FIRMWARE_UPDATE_MD Notification Type Notification Type Event BASIC Report Alarm Type Alarm Level Switch Type Reed Switch Tamper Switch Reed Switch Status 0x06 0x07 Close:0x17, Open:0x16 Tamper Switch Close:0x00, Open:0x03 Reed Switch Reed Switch Tamper Switch Close:0x00, Open:0xFF 0x06 0x07 Close:0x00, Open:0xFF Operation 1. 2. 3. The Green Pairing LED will stay off during the normal operation. The sensor is equipped with a tamper switch. If the cover of sensor is removed, the sensor will send an alarm to the home controller. Tamper switch event will be ignored when in auto inclusion procedure. Certification FCC Statement: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. The FCC ID for this device is P27SWDWS02N You are cautioned that changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. FCC RF Radiation Exposure Statement: • This Transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. • This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V2.3 (128-bit) User Access : Print, Copy, Extract XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Create Date : 2016:03:22 14:52:27+08:00 Creator Tool : pdfFactory Pro www.pdffactory.com Modify Date : 2016:03:22 15:19:40+08:00 Metadata Date : 2016:03:22 15:19:40+08:00 Format : application/pdf Creator : 01318 Title : SW-DWS02N QIG_20160319(EMI 要求更新頻率).docx Producer : pdfFactory Pro 3.51 (Windows 7 Ultimate Chinese (Traditional)) Document ID : uuid:c5e03b35-7b0b-4a4e-b898-7dfb2583a036 Instance ID : uuid:b156239e-9bff-4af8-997d-5fbf94ee82bc Page Count : 4 Page Layout : SinglePage Author : 01318EXIF Metadata provided by EXIF.tools