Sercomm SZKFB01 ZigBee Key Fob User Manual SZ KFB01 Manual 0925
Sercomm Corporation ZigBee Key Fob SZ KFB01 Manual 0925
Sercomm >
User Manual
SZ-KFB01 ZigBee Key Fob Manual / Installation Guide SZ-KFB01 is a professional security token with built-in authentication mechanisms. Just use the Key Fobs and users can have security control wherever inside or outside of their homes. Specification Frequency 2.4GHz 802.15.4 Zigbee system Battery Type DC3V CR2032 * 1 Communication Range Open Air:100M (Max) LED Indicator Red / Green x 1 Operating Temperature 0 C to 50 C (32° - 122°F) Storage Temperature -20 C to 70 C (-4° - 158°F) Battery Life 2 Years Keys : Arm All : Disarm All : Reserved : Arm Perimeter Dimension 56 mm x 38 mm x 16 mm (2.2" x 1.5" x 0.6") Package Contents LEDs Power (Red/Green) On (Red) - When any key is pressed. Blinking (Red) - The command is being processed (2 times per second). Blinking (Green): The LED will blink for 10 seconds when join/leave function is being processed. The LED will be on for 2 seconds when join/leave function is succeeded and then off. Pre-Intallation 1. Use a Phillips head screwdriver to remove the screw in the back of the device. 2. Remove the back and find the supplied battery. 3. Disassemble the circuit board from the device 4. Install the supplied battery. 5. Put the circuit board back into the device. 6. Tighten the back and the device with the screw. 7. The device is ready to be added to the ZigBee Coordinator. Operation Join Function For “Join” a network, please do the following instruction: Put the ZigBee Coordinator into “Permit-Joining” mode. + Arm All button for 1 second. The LED is flashing while Pressed and hold Reserved processing. If the SZ-KFB01 has been joined with the ZigBee Coordinator successfully, the Green LED will be on for 2 seconds and then off. The Green LED will be off instantly if failed. Leave Function For “Leave” a network, please do the following instruction: Pressed and hold Reserved + Disarm All button for 3 seconds to let the SZ-KFB01 be deleted from the ZigBee Coordinator. If the key fob has been deleted successfully, the LED will be on for 1 second and then off. Functions of Keys Arm All Press this button to arm your system in Away mode. Both the interior and exterior zones will be armed, which allows you to exit the premises. Arm Perimeter Press this button to arm your system in Stay mode. All perimeter zones will be armed, such as all windows and doors. But the interior zones will remain inactive, which allows you to stay in the premises without setting off an alarm. Disarm All Press this button to disarm your system. Do not have to enter the access code when using this key to disarm the system. Troubleshooting If the key fob is not working properly during the process, please make sure the battery is installed correctly. FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interfer-ence to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. You are cautioned that changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the follow-ing two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation This Transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This equipment complies with FCC RF radiation exposure limits set forth for an uncon-trolled environment . This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body. CE Approval CE Standards This product complies with the 99/5/EEC directives, including the following safety and EMC standards: EN300328 EN301489 EN55022/24 CE Marking Warning This is a Class B product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : kayla.lin Create Date : 2012:12:06 18:31:14+08:00 Modify Date : 2012:12:06 18:31:14+08:00 XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Creator Tool : PScript5.dll Version 5.2.2 Producer : Acrobat Distiller 9.0.0 (Windows) Format : application/pdf Title : Microsoft Word - SZ-KFB01_Manual_0925.doc Creator : kayla.lin Document ID : uuid:1c1998da-870c-421f-9333-c9553b9ba682 Instance ID : uuid:c1a29d11-1d75-413b-a0c7-d7bd91bd3904 Page Count : 5EXIF Metadata provided by EXIF.tools