Sharp Er A520 Owners Manual

Er-A520-Er-A530-Operation-Manual er-a520-er-a530-operation-manual

2015-03-09

: Sharp Sharp-Er-A520-Owners-Manual-644152 sharp-er-a520-owners-manual-644152 sharp pdf

Open the PDF directly: View PDF PDF.
Page Count: 229

DownloadSharp Sharp-Er-A520-Owners-Manual-  Sharp-er-a520-owners-manual
Open PDF In BrowserView PDF
ER-A520/A530

ELECTRONIC CASH REGISTER

MODEL

ER-A520
ER-A530
INSTRUCTION MANUAL

SHARP ELECTRONICS CORPORATION
Sharp Plaza, Mahwah, New Jersey 07430-2135
1-800-BE-SHARP
http://www.sharp-usa.com

SHARP CORPORATION

The above illustration shows the model ER-A520.
Printed in China
KS(TINSE????RCZZ)➀

WARNING
FCC Regulations state that any unauthorized changes or modifications to
this equipment not expressly approved by the manufacturer could void
the user's authority to operate this equipment.
Note: This equipment has been tested and found to comply with the
limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy
and, if not installed and used in accordance with the instruction manual,
may cause harmful interference to radio communications. Operation of
this equipment in a residential area is likely to cause harmful interference
in which case the user will be required to correct the interference at his
own expense.

CAUTION
The AC outlet shall be installed near the equipment and shall be easily
accessible.

FOR YOUR RECORDS
Please record below the model number and serial number, for easy
reference, in case of loss or theft. These numbers are located on the
right side of the unit. Space is provided for further pertinent data.
Model Number
Serial Number
Date of Purchase
Place of Purchase

INTRODUCTION
Thank you very much for your purchase of the SHARP Electronic Cash Register, Model ER-A520/A530.
Please read this manual carefully before operating your machine to gain a thorough understanding of the
functions and features offered by this model ECR.
Please keep this manual for future reference, it may help you if you encounter operational problems.

IMPORTANT
• Install your register in a location that is not subject to direct radiation, unusual temperature changes,
high humidity or exposed to water sources.
Installation in such locations could cause damage to the cabinet and the electrical components.
• The register should not be operated by an individual with wet hands.
The water could seep into the interior of the register and cause component failure.
• When cleaning your register, use a dry, soft cloth. Never use solvents, such as benzine and/or thinner.
The use of such chemicals will lead to discoloration or deterioration of the cabinet.
• The register plugs into any standard wall outlet (120V ±10% AC) which utilizes a dedicated ground
circuit.
Please note that other electrical devices on the same electrical circuit could cause the register to malfunction.
• If the register malfunctions, call your local dealer for service - do not try to repair the register yourself.
• For a complete electrical disconnection, the AC power cord must be removed from the wall outlet.
• Never disconnect the peripheral while the register remains plugged into the AC outlet.

PRECAUTION
This Electronic Cash Register has a built-in memory protection circuit which is supported by rechargeable
batteries.
It is important to know that all batteries will, in time, dissipate their charge even if not used. Therefore to insure
an adequate charge in the protection circuit, and to prevent any possible loss of memory during or after
installation, it is recommended that each unit be allowed to recharge for a period of 24 to 48 hours prior to and
during use by the customer.
In order to charge the batteries, the machine must be plugged in. This recharging precaution can prevent
unnecessary equipment malfunctions or service calls.

1

CONTENTS
INTRODUCTION ····················································································································································1
IMPORTANT ··························································································································································1
PRECAUTION························································································································································1
CONTENTS····························································································································································2
EXTERNAL VIEW OF THE ER-A520 ····················································································································8
Front view ···············································································································································8
Rear view················································································································································8
EXTERNAL VIEW OF THE ER-A530 ····················································································································9
Front view ···············································································································································9
Rear view················································································································································9
PRINTER······························································································································································10
KEYBOARD ·························································································································································11
1 ER-A520 standard keyboard layout·········································································································11
2 ER-A530 standard keyboard layout·········································································································13
3 Standard key number layout····················································································································15
4 Installing the keyboard sheet (ER-A530) ·································································································16
KEYS AND SWITCHES ·······································································································································17
1 Mode switch and mode keys ···················································································································17
2 Drawer lock key ·······································································································································17
3 Printer cover lock key ······························································································································18
4 Cashier/Server code entry key ················································································································18
5 Receipt ON/OFF function ························································································································18
DISPLAYS ···························································································································································19
1 Operator display ······································································································································19
2 Customer display (Pop-up type) ··············································································································19
FOR THE OPERATOR
PRIOR TO ENTRIES ···········································································································································20
1 Preparations for entries ···························································································································20
2 Power save mode ····································································································································21
3 Error warning ···········································································································································21
ENTRIES ······························································································································································22
1 Item entries ··············································································································································22
Single item entries ································································································································22
Repeat entries ······································································································································23
Multiplication entries ·····························································································································24
Successive multiplication entries··········································································································25
Split-pricing entries ·······························································································································26
Single item cash sale (SICS)/single item finalize (SIF) entries·····························································27
Scale entries·········································································································································28
PLU level shift (for direct PLU) ·············································································································30
PLU/UPC price level shift ·····················································································································32
Set PLU entries ····································································································································33
Link PLU/UPC entries···························································································································34
Age verification (Birthday entry) ···········································································································34
Mix-and-match entries ··························································································································35
Condiment entries (for PLUs) ···············································································································35
Price inquiry (view) function (for PLU/UPCs)························································································36
UPC learning function···························································································································37
Price change function (for PLU/UPCs) ·································································································38
2 Displaying and printing subtotals ·············································································································40
Merchandise subtotal ···························································································································40

2

Taxable subtotal ···································································································································40
Including-tax subtotal (full subtotal) ······································································································40
Food stamp-eligible subtotal·················································································································40
Tray subtotal·········································································································································40
Eat-in subtotal·······································································································································40
Gasoline discount subtotal ···················································································································40
3 Finalization of transaction ························································································································41
Cash or Check tendering······················································································································41
Mixed tendering (check + cash)············································································································41
Cash or Check sale that does not need any tender entry ····································································42
Charge (credit) sale ······························································································································42
Mixed-tender sale (cash or check tendering + charge tendering) ························································42
4 Food stamp calculations ··························································································································43
Food stamp tendering···························································································································43
Food stamp status shift ························································································································44
5 Tax calculations ·······································································································································45
Automatic tax········································································································································45
Manual tax ············································································································································45
Automatic-tax delete·····························································································································46
Tax status shift ·····································································································································47
6 Guest check (GLU/PBLU) ·······················································································································48
GLU/PBLU system ·······························································································································48
Deposit entries······································································································································51
Transferring guest checks out or in (Transfer-out/in) ···········································································52
Bill totalizing/bill transfer ·······················································································································53
Bill separating ·······································································································································54
Manual Previous Balance(PB) and Charge Balance(CB) entry ···························································55
7 Auxiliary entries ·······································································································································57
Percent calculations (premium or discount) ·························································································57
Discount entries····································································································································58
Refund entries ······································································································································59
Return entries ·······································································································································59
Refund sales mode·······························································································································60
Printing of non-add code numbers ·······································································································60
Gratuity ·················································································································································61
8 Payment treatment ··································································································································62
Tip-in entries·········································································································································62
Tip editing ·············································································································································63
Tip paid entries ·····································································································································63
Currency conversion·····························································································································64
Received on account entries ················································································································65
Paid out entries·····································································································································65
No sale (exchange) ······························································································································65
Cashing a check ···································································································································66
Bottle return ··········································································································································66
9 Automatic sequencing key entries ···········································································································66
10 WASTE mode ··········································································································································67
CORRECTION ·····················································································································································68
1 Correction of the last entry (direct void)···································································································68
2 Correction of the next-to-last or earlier entries (indirect void)··································································68
3 Subtotal void ············································································································································69
4 Correction of incorrect entries not handled by the direct or indirect void function ···································69
CORRECTION AFTER FINALIZING A TRANSACTION (AFTER GENERATING A RECEIPT)························70
OVERRIDE ENTRIES ··········································································································································71
OVERLAPPED CASHIER/SERVER ENTRY ······································································································72
SPECIAL PRINTING FUNCTIONS······················································································································73
1 Copy receipt printing································································································································73

3

2 Validation printing function (Slip printer) ··································································································74
3 Bill printing ···············································································································································74
4 Printing of the employee’s arrival and departure times (Slip printer) ·······················································74
5 Printing of header and footer graphic logos·····························································································75
6 Remote printer send function ··················································································································75
TIME DISPLAY AND AUTOMATIC UPDATING OF THE DATE ········································································76
1 Time display ············································································································································76
2 Automatic updating of the date ················································································································76
FOR THE MANAGER
PRIOR TO PROGRAMMING ·······························································································································77
1 Programming keyboard layout·················································································································77
2 How to program alphanumeric characters·······························································································78
Using character keys on the keyboard ·································································································78
Entering character codes······················································································································78
PROGRAMMING ·················································································································································80
Basic instructions··································································································································80
Preparations for programming··············································································································80
Direct Programming ···········································································································································80
1 Setting the date and time·························································································································80
Date ······················································································································································80
Time······················································································································································81
2 Programming for departments ·················································································································81
Unit price ··············································································································································81
Functional selection······························································································································82
3 PLU/UPC programming ···························································································································84
Unit price ··············································································································································84
Functional selection······························································································································85
Associated department·························································································································86
4 Programming for discount keys (-) ······································································································87
Discount amount ··································································································································87
Functional programming·······················································································································87
5 Programming for percent keys (%)········································································································88
Percent rate ··········································································································································88
Functional programming·······················································································································89
6 Programming for conversion keys (ç) ··································································································90
Currency conversion rate ·····················································································································90
7 Programming for the r, p, and † keys ···························································································90
High amount lockout (HALO)················································································································90
8 Programming for the a, CA , ', and k keys···················································································91
High amount lockout (HALO) and function selection············································································91
9 Programming for the automatic tax calculation function ··········································································93
The tax table (applicable to the add-on tax) ·························································································93
Job-Code-Based Programming ························································································································96
1 Setting the date and time·························································································································96
Setting the date (#2610) ·······················································································································96
Setting the time (#2611) ·······················································································································96
2 Setting the register and consecutive numbers ························································································97
Setting the register number (#2612)·····································································································97
Setting the consecutive number (#2613)······························································································97
3 Programming for the automatic tax calculation function ··········································································98
The tax table (#2710) ···························································································································98
The tax rate (#2711) ···························································································································100
Doughnut tax exempt (for the Canadian tax system) (#2715)····························································101
4 Programming for departments ···············································································································102
Functional programming 1 (#2110) ····································································································102

4

Functional programming 2 (#2111) ····································································································104
A limit amount (HALO) of entry (#2112) ·····························································································105
Item label (#2114)·······························································································································105
Unit price (#1110) ·······························································································································106
Commission group assignment (#2115)·····························································································106
Group number (#2116) ·······················································································································107
Group text (#2350) ·····························································································································107
Age limitation (#2180)·························································································································108
Print station assignment (#2118)········································································································108
Department key positioning (#2119)···································································································109
Color Video Monitor (CVM) control character (#2158) ·······································································109
5 PLU/UPC programming ·························································································································110
Associated department (#1200, 2230, 1050) ·····················································································111
Unit prices (#1210, 1060) ···················································································································113
Base quantity (#1211, 1061) ··············································································································114
Functional programming 1 (#2210, 2231, 2060) ················································································114
Functional programming 2 (#2211, 2232, 2061) ················································································116
Item label (#2214, 2064)·····················································································································118
Commission groups (#2215, 2235, 2065) ··························································································119
Group number (#2216, 2066) ·············································································································120
Group text (#2351) ·····························································································································120
Age limitation (#2280, 2236, 2081)·····································································································121
Stock quantity (#1222, 1220, 1221)····································································································122
Set PLU (#2221)·································································································································123
Mix-and-match table (#2217, 2225, 2067)··························································································124
PLU condiment table (#2222, #2223)·································································································125
Print station to PLU/UPC assignment (#2218, 2068) ·········································································127
Delete period for non-accessed UPC codes (#2029) ·········································································128
Programming Non-PLU code format (#2025)·····················································································129
Link PLU/UPC link (#2220)·················································································································130
Programming of PLU levels and direct PLU keys (#2219) ·································································130
Item label for remote printer (#2244, 2094) ························································································131
Color Video Monitor (CVM) control character (#2258, 2234, 2059) ···················································132
6 Programming for miscellaneous keys····································································································133
CA
CH
, TIP
) and discount (-) (#1310) ····································133
Rate (%, ç, commission, gratuity, TIP
Gas discount unit price (#1311)··········································································································134
Currency description text (ç) (#2334)······························································································134
CA
CH
, TIP
, r, p) (#2312) ····················135
A limit amount (HALO) of entry (-, † (for manual tax), TIP
+/– sign, food stamp status and tax status (%, -, gratuity) (#2311)··············································136
Percent entry type (%) (#2310) ········································································································137
Item % or subtotal % selection (%) (#2315) ·····················································································138
Percent rate limitation (%) (#2313)···································································································138
Vendor or store coupon selection (-) (#2316)·················································································139
7 Programming for the media keys···········································································································140
Functional programming 1 (#2320) ····································································································140
Functional programming 2 (#2326) ····································································································142
High amount lockout (HALO) for check cashing, check change, and cash in drawer (#2321)···········143
High amount lockout (HALO) of entry for media keys (#2322)···························································143
Print station assignment (#2328)········································································································144
CAT programming (#2330)·················································································································145
8 Programming of function text·················································································································146
Programming (#2314)·························································································································146
List of function texts····························································································································146
9 Server/Cashier programming ················································································································150
Server/Cashier code (#1400) ·············································································································150
Server/Cashier name (#1414) ············································································································150

5

Functional programming (#2410) ·······································································································151
GLU/PBLU code range assignment (#2411) ······················································································151
Net sales % rate (#2413)····················································································································152
10 Programming various functions ·············································································································152
Programming for optional feature selection (#2616) ··········································································152
Programming the parameter of the slip printer (#2615)······································································157
Setting the time limit for THE TILL TIMERTM (#2617) ·········································································158
Scale tare table (#2618) ·····················································································································158
Programming of logo messages (#2614) ···························································································159
Selection of X1/Z1 and X2/Z2 reports to be printed in the stacked report sequence (#2620)············160
Setting the time range for hourly reports (#2619)···············································································161
Programming of power save mode (#2689) ·······················································································161
Available GLU/PBLU codes (#2810) ··································································································162
Bill number (#2636) ····························································································································162
Functional programming for the printer (#2990) ·················································································163
Editing guidance/error messages (#2641)··························································································163
Validation message (#2642)···············································································································165
Slip printer’s logo message (#2643) ···································································································165
RS-232C channel assignment (#2690) ······························································································166
Barcode reader programming (#2691) ·······························································································167
Remote printer assignment (#2692) ···································································································168
Second remote printer assignment (#3653) ·······················································································168
Remote printer name (#3654) ············································································································169
Print format for remote printer (#3655) ·······························································································169
Chit receipt format (#3656)·················································································································170
RS-232C interface (#6110, 6111, 6112, 6113, 6115, 6212, 6213, 6220)···········································171
Programming the CAT interface (#7110, 7111, 7112, 7113, 7114, 7115, 7116)································173
Secret codes to control access to the PGM1 mode, X1/Z1 mode and X2/Z2 mode
(#2630, 2631, 2632) ···························································································································175
Loading dynamic UPCs to the main UPC file (#2099)········································································175
Setting the AUTO key (#2900) ···········································································································176
11 TRAINING mode ···································································································································177
12 Reading stored programs ······················································································································178
Program details and procedures for their reading ··············································································178
Sample printouts·································································································································180
13 Universal Product Code (UPC) or European Article Number (EAN) ·····················································188
UPC or EAN code·······························································································································188
Add-on code ·······································································································································189
READING (X) AND RESETTING (Z) OF SALES TOTALS···············································································190
1 Summary of reading (X) and resetting (Z) reports and the key operations to obtain the reports ··········190
2 Daily sales totals····································································································································195
General report ····································································································································195
Cashier/Server report ·························································································································199
Hourly report·······································································································································200
Full department report ·······················································································································201
Individual group total report on department························································································201
Full group total report on department ·································································································201
PLU/UPC report (by designated range or pick up list)········································································202
PLU/UPC report by associated department ·······················································································204
Individual group total report on PLU/UPC ··························································································204
Full group total report on PLU/UPC····································································································204
PLU/UPC zero sales report by department ························································································205
PLU/UPC price category report ··········································································································205
PLU/UPC stock report (by designated range or pick up list) ······························································205
Commission sales report ····················································································································205
GLU/PBLU report ·······························································································································206
GLU/PBLU report by cashier/server ···································································································206

6

Closed GLU/PBLU report ···················································································································207
Closed GLU/PBLU report by cashier/server·······················································································208
Transaction report ······························································································································209
Tax report ···········································································································································209
Cash in drawer report ·························································································································209
Dynamic UPC report (by designated range or pick up list)·································································210
Dynamic UPC report by associated department ················································································210
Dynamic UPC clear (by designated range or pick up list) ··································································210
Dynamic UPC clear by associated department ··················································································210
X1/Z1 stacked report ··························································································································210
Deleting of non-accessed UPCs·········································································································211
3 Periodic consolidation····························································································································212
General Overview·······························································································································212
Daily net report ···································································································································212
X2/Z2 stacked report ··························································································································212
COMPULSORY CASH/CHECK DECLARATION······························································································213
OPERATOR MAINTENANCE ···························································································································215
1 In case of power failure ·························································································································215
2 In case of printer error ···························································································································215
3 Thermal printing·····································································································································215
Cautions in handling the printer··········································································································215
Cautions in handling the recording paper (thermal paper) ·································································216
4 Installing and removing the paper roll····································································································217
Recording paper specifications ··········································································································217
Installing the paper roll ·······················································································································217
Removing the paper roll ·····················································································································218
Removing a paper jam ·······················································································································220
5 Cleaning the print head ·························································································································221
6 Removing the till and the drawer ···········································································································222
7 Opening the drawer by hand ·················································································································222
8 Before calling for service ·······················································································································223
Error message table ···························································································································223
LIST OF OPTIONS ············································································································································224
SPECIFICATIONS ·············································································································································225

7

EXTERNAL VIEW OF THE ER-A520
Front view
Customer display (Pop-up type)
Printer cover

Receipt paper

Operator display

Journal window

Keyboard
Mode switch

Drawer
Drawer lock

Rear view

Printer cover lock
(left side)

Rear cover

8

EXTERNAL VIEW OF THE ER-A530
Front view
Customer display (Pop-up type)
Printer cover

Operator display
Receipt paper
Journal window

Keyboard
Mode switch

Drawer
Drawer lock

Rear view

Printer cover lock
(left side)

Rear cover

9

PRINTER
The printer is a receipt/journal dual station type thermal printer which delivers fast, quiet and high quality
printing. The average life of the printer is approximately 5 million lines.
When opening the printer cover, unlock the printer cover
using the printer cover lock key, and lift up the cover as
shown in the diagram to the right.

Printer cover

Printer lock key

Your register is shipped with the print head release lever
held in the up position by a white shipping retainer. Be sure
to remove this retainer (see the figure at the right) and
push down the print head release lever before you use the
register.
Retainer

Print head release lever
The print head can be lifted by
the green lever on the right side
of the printer. Pulling the lever
forward, lifts the print head up. If
the paper becomes jammed and
you need to move the print head
farther forward, you can pull the
lever even further toward you
and proceed with the removal of
the jammed paper.

Take-up spool

Paper roll location

Paper chute

Print head
release lever

Note

10

Do not attempt to remove the paper roll with the head in the down position. This may result in
damage to the printer and print head.

KEYBOARD
1 ER-A520 standard keyboard layout
NC
SLIP RCPT PBLU

CASH
#

@
FOR

INQ

FS AUTO
SHIFT
1

.L

5

10

15

20

FS AUTO
TEND
2

7

8

9

4

9

14

19

NS

CH1

%1

TAX

4

5

6

3

8

13

18

CHK

CH2

TAX
SHIFT

1

2

3

2

7

12

17

MDSE
SBTL

SBTL

00

1

6

11

16

PO

RFND VOID #/TM

0

CA/AT

All keys except the receipt paper feed and journal paper feed keys can be re-positioned.
If you want to change the layout, please consult your authorized SHARP dealer.

RECEIPT

Receipt paper feed key

JOURNAL

Journal paper feed key

0

AMT

CONV RA FINAL

%2

Note

PRICE
CHANGE

PLU/UPC

9

Discount 1 key
%1

Percent 1 and 2 keys

%2

New check key

NC

Numeric keys

00
•

Decimal point key

CL

Clear key

@

Multiplication key

RFND

Refund key

VOID

Void key

AMT

Amount entry key

FOR

PBLU

Previous balance key

FINAL

Final key
No-sale key

NS
TAX
SHIFT

TAX 1 shift key

TAX

Manual tax key

MDSE
SBTL

1
AUTO
1

Merchandise subtotal key
20
AUTO
2

Department keys
Automatic sequencing
1 and 2 keys

CASH
#

Cashier code entry key

PLU/UPC

PLU/UPC key

RA

Received-on-account 1 key

PLU/UPC inquiry key

PO

Paid-out 1 key

INQ
PRICE
CHANGE

UPC price change key

FS
SHIFT

Food stamp shift key

11

FS
TEND

Food stamp tender key

CA/AT

Cash/amount tendered key

Charge 1and 2 keys

RCPT

Receipt print key

Currency conversion key

SLIP

Slip printer key

CHK

Check 1 key

#/TM

Non-add code/Date & time
display key

SBTL

Subtotal key

CH
1

CH
2

CONV

Note

The following function keys can optionally be mounted in place of those shown in the figure of the
standard keyboard layout. For details, please consult your authorized SHARP dealer.

Optional keys
DEPT
#

Dept. number key

Tip paid key

%3

%5

Percent 3 thru 5 keys

EAT IN
1

EAT IN
3

Eat in 1 thru 3 keys

-2

-5

Discount 2 thru 5 keys

TAX2
SHIFT

TAX4
SHIFT

Tax 2 thru 4 shift keys

CH3

CH9

Charge 3 thru 9 keys

DEPO

Deposit key

CA2

CA5

Cash 2 thru 5 keys

DEPO
RFND

Deposit refund key

CONV2

CONV4

Currency conversion 2 thru 4 keys

LEVEL
#

PLU level shift number key

RA2

Received-on-account 2 key

RP
SEND

Remote printer send key

PO2

Paid-out 2 key

GRT
EXEMPT

Gratuity exempt key

Automatic sequencing
3 thru 10 keys

OPEN
TARE

Tare entry key

SRVC

Service key

REPEAT

Repeat entry key

TRAY
SBTL

Tray subtotal key

AUTO
3

AUTO
10

RETURN

CHK2

12

TIP
PAID

CHK5

GAS
SBTL

Gasoline sales subtotal key

Return key

P-SHIFT
#

Price shift number key

Check 2 through 5 keys

SCALE

Scale entry key

TRANS
OUT

Transfer out key

L1

L5

PLU level shift 1 thru 5 keys

TRANS
IN

Transfer in key

P1

P6

Price level shift 1 thru 6 keys

CA
TIP

Cash tip key

CH
TIP

Charge tip key

PRINT
CV
CNT

Validation print key
Cover count entry key

No delete key

C
NEXT

Condiment next key

BS

Bill separation key

C
CANCEL

Condiment cancel key

BT

Bill totalize/Bill transfer key
(CHECK-ADD)

NO DEL

EDIT
TIP

BIRTH

Birthday entry key

GLU
RECALL

RFND
SALES

Refund sales key

000

WASTE

Waste mode key

Edit tip key
Table# recall key
Numeric key

The department and direct PLU keys may be expanded. If you require expansion of the department
or direct PLU keys, please contact your dealer.

Note

2 ER-A530 standard keyboard layout
L2

RCPT

%

VOID

INQ

RP
SEND

AUTO
3

RFND

PLU/
SUB

NC

CONV

PBAL

CH1

8

CL
9

SRVC

CH2

4

5

6

FINAL

CH3

22

1

2

3

MDSE
SBTL

CHK

11

0

00 000

SBTL

CA/AT

JOURNAL

91

92

93

94

95

96

97

98

99

100

79

80

81

82

83

84

85

86

87

88

89

90

67

68

69

70

71

72

73

74

75

76

77

78

56

57

58

59

60

61

62

63

64

65

66

SERV
#

45

46

47

48

49

50

51

52

53

54

55

FOR

34

35

36

37

38

39

40

41

42

43

44

7

23

24

25

26

27

28

29

30

31

32

33

12

13

14

15

16

17

18

19

20

21

1

2

3

4

5

6

7

8

9

10

@

Note

L3

AUTO
2

• All keys except the receipt paper feed and journal paper feed keys may be re-positioned.
If you want to change the keyboard layout, please consult your dealer.
• Please note that the price lookup/subdepartment/UPC key (P) and the previous balance key
( PBAL ) are shown as PLU/
and u respectively in this manual.
UPC

RECEIPT

Receipt paper feed key

@

FOR

Multiplication key

JOURNAL

Journal paper feed key

RCPT

Receipt print key

RFND

Refund key

VOID

Void key

PLU/
SUB

Price lookup/subdepartment/
UPC key

0

AUTO
1

L1

RECEIPT

9
Numeric keys

00
•
CL

000
Decimal point key
Clear key

1

100

Direct price lookup keys

13

L1

L3

NC

PLU level shift 1 thru 3 keys

AUTO
1

New check key

CONV
CH
1

AUTO
3

Automatic sequencing
1 thru 3 keys
Currency conversion key

CH
3

Charge 1 thru 3 keys

SRVC

Service key

FINAL

Final key

CHK

Check 1 key

PBAL

Previous balance key

MDSE
SBTL

Merchandise subtotal key

Discount 1 key

SBTL

Subtotal key

Percent 1 key

CA/AT

Cash/amount tendered key

INQ

PLU/UPC inquiry key

RP
SEND

Remote printer send key

SERV
#

Server code entry key

%

The following function keys can optionally be added in place of those shown in the figure of the
standard keyboard layout. For details, please consult your authorized SHARP dealer.

Note

Optional keys
DEPT
#

CH
TIP

Charge tip key

%2

%5

Percent 2 thru 5 keys

TIP
PAID

-2

-5

Discount 2 thru 5 keys

EAT IN
1

EAT IN
3

Eat in 1 thru 3 keys

CH4

CH9

Charge 4 thru 9 keys

TAX1
SHIFT

TAX4
SHIFT

Tax 1 thru 4 shift keys

CA2

CA5

Cash 2 thru 5 keys

DEPO

Deposit key

CONV2

CONV4

Currency conversion 2 thru 4 keys

DEPO
RFND

Deposit refund key

TAX

RA1

RA2

Received-on-account 1 and 2 keys

PO1

PO2

Paid-out 1 and 2 keys

TRAY
SBTL
RETURN

Tip paid key

Manual tax key
Tray subtotal key

AUTO
4

AUTO
10

Automatic sequencing
4 thru 10 keys

CHK2

CHK5

Check 2 through 5 keys

GAS
SBTL

Gasoline sales subtotal key

TRANS
OUT

Transfer out key

#/TM

Non-add code/Date & time
display key

TRANS
IN

Transfer in key

CA
TIP

14

Dept. number key

Cash tip key

NS

SCALE

Return key

No-sale key
Scale entry key

LEVEL
#

PLU level shift number key

L4

PLU level shift 4 and 5 keys

L5

P-SHIFT
#

REPEAT

Repeat entry key

AMT

Amount entry key

Price shift number key

PRICE
CHANGE

UPC price change key

Price level shift 1 thru 6 keys

BIRTH

Birthday entry key

Validation print key

RFND
SALES

Refund sales key

CV
CNT

Cover count entry key

WASTE

Waste mode key

SLIP

Slip printer key

C
NEXT

Condiment next key

BS

Bill separation key

C
CANCEL

Condiment cancel key

BT

Bill totalize/Bill transfer key
(CHECK-ADD)

P1

P6

PRINT

EDIT
TIP

Edit tip key

NO DEL

No delete key

GLU
RECALL

Table# recall key

GRT
EXEMPT

Gratuity exempt key

FS
SHIFT

Food stamp shift key

OPEN
TARE

Tare entry key

FS
TEND

Food stamp tender key

Note

Department and direct PLU keys can be expanded. If you require expansion of the department or
direct PLU keys, please contact your authorized SHARP dealer.

3 Standard key number layout
These key numbers are used for positioning of department keys and direct PLU keys. For further details with
positioning departments and PLU keys, please refer to pages 109 and 130.
This layout can be changed by your dealer.
For ER-A520

005

010

015

020

004

009

014

019

003

008

013

018

002

007

012

017

001

006

011

016

15

For ER-A530

111

112

113

114

115

116

117

118

119

120

104

105

106

107

108

109

110
098

099

100

101

102

103

087

088

089

090

091

092

093

094

095

096

097

076

077

078

079

080

081

082

083

084

085

086

065

066

067

068

069

070

071

072

073

074

075

054

055

056

057

058

059

060

061

062

063

064

043

044

045

046

047

048

049

050

051

052

053

032

033

034

035

036

037

038

039

040

041

042

021

022

023

024

025

026

027

028

029

030

031

4 Installing the keyboard sheet (ER-A530)
Insert the keyboard sheet between the keyboard cover and the cabinet as illustrated below. Then press the
claws at the top of the keyboard cover into the slots in the cabinet.

Keyboard
sheet

Keyboard cover
Cabinet

Note

16

• Do not spread the keyboard cover too far to avoid tearing the tabs.
• Replace the keyboard sheet with a new one if by chance it gets wet. Use of a wet keyboard
sheet may cause problems.
• Be sure to use only SHARP-supplied keyboard sheets. Thick or hard sheets can make key
operations difficult.
• Place the keyboard sheet evenly under the keyboard cover.
• If you require a new keyboard sheet, please contact your dealer.
• The keyboard cover will eventually wear out. If your keyboard cover is dirty or broken, replace the
cover with a new one. For details, please contact your authorized SHARP dealer.

KEYS AND SWITCHES
1 Mode switch and mode keys
The mode switch can be operated by inserting one of the three supplied mode keys – manager (MA),
submanager (SM), and operator (OP) keys. These keys can be inserted or removed only when the switch is in
the “REG” or “OFF” position.
• Manager key (MA)

Operative range

• Submanager key (SM)

SM

MA

• Operator key (OP)

OP

The mode switch has these settings:
OFF:

This mode locks all register operation.
No change occurs to register data.
OP X/Z: This setting allows cashiers to take X or Z reports for their sales
information. It can also be used for displaying the date/time and
printing the employee’s arrival/departure times. And it can be used to toggle receipt state “ON” and
“OFF” by pressing the q key. (This setting may be used only when your register has been
programmed for “OP X/Z mode available” in the PGM2 mode.)
REG:
For entering sales
PGM1: To program those items that need to be changed often: e.g., unit prices of departments, PLUs or
UPCs, and percentages.
PGM2: To program all PGM1 programs and those items that do not require frequent changes: e.g., date,
time, or a variety of register functions.
MGR:
For manager’s and submanager’s entries
The manager can use this mode to make entries that are not permitted to be made by cashiers – for
example, after-transaction voiding and override entries.
X1/Z1: To take the X/Z report for various daily totals.
X2/Z2: To take the X/Z report for various periodic (weekly or monthly) consolidation of totals.

2 Drawer lock key

SK1-1

This key locks and unlocks the drawer. To lock it, turn 90 degrees counterclockwise. To unlock it, turn 90
degrees clockwise.

17

3 Printer cover lock key
This key locks and unlocks the printer cover. To lock it, turn 90 degrees
counterclockwise. To unlock, turn 90 degrees clockwise.

4 Cashier/Server code entry key

✱
✱
✱
✱

The ER-A520 provides a cashier system and the ER-A530 provides a server system. The cashier/server codes
are available in two variants: Variant 1, the codes are displayed (“0000” to “9999”), and Variant 2, the codes are
not displayed (always “
”).
When the cashier/server code is assigned by Variant 2 (codes not displayed), the register prints
as the
cashier/server code and the cashier/server name are printed both on the receipt and journal for every
transaction.
✱
✱
✱
✱

Procedure
■ Sign-on

■ Sign-off
Variant 1 / Variant 2 :
To display the current cashier/server code

‹/‹ ‹/‹
SERV

Variant 1 :
(Code is displayed.)
Variant 2 :
(Code is not displayed.)

Note

Cashier/server
code

‹/‹
SERV

‹/‹
‹/‹

Cashier/server
code

SERV

SERV

SERV

All settings depend on how the register has been programmed. For the available selection of these
settings, please consult your authorized SHARP dealer.

5 Receipt ON/OFF function
You can disable receipt printing in the REG mode to save paper using the receipt function. To disable receipt
printing, press the q key in the OP X/Z position. This key toggles the receipt printing status ON and OFF. To
check the receipt printing status, turn the mode switch to the OP X/Z position or press the c key in the REG
mode. When the function is in the OFF status, the receipt off indicator “_” illuminates.

Note

18

Your register will print reports regardless of the receipt status. This means that the receipt roll must
be installed even when the receipt state is “OFF” when taking reports.

DISPLAYS
1 Operator display
The operator display consists of a two-line dot-matrix display (16 characters/line).
Price level / PLU level (e.g. P2L3)

Dept. name / PLU or UPC name / function text

Cashier/server code or mode name

Function message display area

Numeric entry display area

Receipt OFF indicator (“_”) / Stock alarm indicator (“•”)
Repeat / Sentinel mark / Power save mark

• Cashier/server code or mode name
The mode you are in is displayed. When a cashier/server is assigned, the cashier/server code is
displayed in the REG or OP X/Z mode. For example, “0001” is displayed when cashier/server 0001 is
assigned.
• Repeat
The number of repeats is displayed, starting at “2” and increments with each repeat. When you have
registered an item ten times, the display will show “0”. (2 ➞ 3 ......9 ➞ 0 ➞ 1 ➞ 2...)
• Sentinel mark
When amounts in the drawer reaches the amount you preprogrammed, the sentinel mark “X” is
displayed to advice you to remove the money to a safe place.
• Power save mark
When the cash register goes into the power save mode, the power save mark (decimal point) is
displayed.
• Stock alarm indicator
When the stock counter of the PLU or UPC which you entered is zero or negative, the alarm indicator
(decimal point) is displayed.
• Function message display area
Item labels of departments and PLU/subdepartments/UPC and function text you use, such as %1, (–)
and CASH are displayed here. For the details of function texts, please refer to pages 146 to 149.
When an amount is to be entered or entered, “AMOUNT” is displayed: When an amount is to be
entered, – – – – – – – is displayed in the numeric entry display area with “AMOUNT”. When a preset
price has been set, the price is displayed in the numeric entry display area with “AMOUNT”.
• Numeric entry display area
Numbers entered using numeric keys are displayed here.
Date and time display
Date and time appear on the display in the OP X/Z, REG, or MGR mode. In the REG or MGR mode, press
#/
the TM
key to display the date and time.
Error messages
When an error occurs, the corresponding error message is displayed in the function message display area.
For the details of error messages, please refer to the “Error message table” on page 223.

2 Customer display (Pop-up type)

19

FOR THE OPERATOR

PRIOR TO ENTRIES
1 Preparations for entries
Before registrations, insert the operator key into the mode switch and turn it to the REG position and check the
following items:

Receipt and journal paper rolls
If the receipt and journal paper rolls are not set in the machine or there are low rolls, install new ones according
to section “4. Installing and removing the paper rolls” under “OPERATOR MAINTENANCE.”

Receipt ON/OFF function
You can disable receipt printing in the REG mode to save paper using the receipt function. To disable receipt
printing, press the q key in the OP X/Z position. This key toggles the receipt printing status ON and OFF.
To check the receipt printing status, turn the mode switch to the OP X/Z position or press the c key in the REG
mode. When the function is in the OFF status, the receipt off indicator “_” illuminates.

Note

Your register will print reports regardless of the receipt state. This means that the receipt roll must
be installed even when the receipt state is “OFF” when taking reports.

Cashier/Server assignment
The ER-A520 requires a cashier to be assigned prior to operational item entries. The ER-A530 enforces that a
server must enter their code into the register. Depending on register settings, it is possible to keep the same
cashier/server code assigned when the same cashier/server is to be used for all transactions within a set period.
As previously mentioned, there are two variants to consider for the display and print of the cashier/server codes.

Logo message or graphic logo
(varies depending on
programming.)

✱
✱
✱
✱

Cashier/Server code
(“
” is printed in Variant 2.)
Cashier/Server name

Note

20

The operation entries depend on how the register has been programmed. To determine which
selections should be considered, please consult your local dealer.

Procedure
■ Sign-on

■ Sign-off
Variant 1 / Variant 2 :
To display the current cashier/server code

‹/‹ ‹/‹
SERV

Variant 1 :
(Code is displayed.)
Variant 2 :
(Code is not displayed.)

Note

Cashier/server
code

‹/‹
SERV

‹/‹
‹/‹

Cashier/server
code

SERV

SERV

SERV

• If you want to enter a cashier/server code before every transaction, please consult your authorized
SHARP dealer.
• For the display type selection of the cashier/server code, “Variant 1” has been preset. For the
selection of the “Variant 2”, consult your authorized SHARP dealer.
• The cashier/server can be changed during a transaction. Please consult your authorized SHARP
dealer.

2 Power save mode
The register will enter into the power save mode when no entries are performed based on the pre-programmed
time limit (by default, 30 minutes).
When the register goes to the power save mode, the operator and customer displays will turn off. This is
indicated by a decimal point at the left most position of the lower line. The register will return to normal operation
mode when any key is pressed or a mode is changed with the mode key. Please note when the register is
recovered by any key entry the initial key entry is ignored. After the recovery, you may start the key entries from
the beginning.

3 Error warning
In the following examples, your register will go into an error state accompanied with a warning beep and a
corresponding error message. Clear the error state by pressing the c key and take proper action.
Please refer to the error message table on page 223.
• When you enter an over 32-digit number (entry limit overflow): Cancel the entry and re-enter a valid number.
• When you make an error in key operation: Clear the error and continue entries.
• When you make an entry beyond a programmed amount entry limit: Check to see if the entered amount is
correct. If it is correct, it be possible to make the entry in the MGR mode. Contact your manager.
• When an including-tax subtotal exceeds eight digits: Clear the subtotal by pressing the c key and press the
a, Å thru É, k, CHK2 thru CHK5 , or h thru CH9 key to finalize the transaction.

21

ENTRIES
Note

The example entries provided within this manual describe the function key labeled PLU/
which is
UPC
used for the model ER-A520. For the model ER-A530, please substitute the PLU/
key
with
the P
UPC
function key.

1 Item entries
Single item entries
Procedure
Department entries (direct department entries)
Enter a unit price and press a department key. If you use a programmed unit price, press a department key only.
When using a programmed unit price

*Less than the programmed upper limit amounts
Unit price *
(max. 7 digits)

Note

Department key

When those departments for which the unit price has been programmed as zero (0) are entered,
only the sales quantity is added.

Department entries (indirect department entries)
When using a programmed unit price
Dept. code
(1–99)

à

Unit price *
(max. 7 digits)

à å
or

*Less than the programmed upper limit
amounts

When [preset only dept.] is entered.

PLU entries (indirect PLU entries)
Enter a PLU code and press the PLU/
key.
UPC
PLU/
UPC

PLU code

Note

When those PLU’s for which the unit price has been programmed as zero (0) are entered, only the
sales quantity is added.

Subdepartment (open PLU, open and preset PLU) entries
When using a programmed unit price
PLU code

PLU/
UPC

Unit price *
(max. 7 digits)

PLU entries (direct PLU entries)
When using a programmed unit price
Unit price *
(for subdept.)

22

Direct PLU key

PLU/
UPC

or

å

*Less than the programmed upper limit
amounts

UPC entries
Scan UPC code

Ä
PLU/
UPC

UPC code
(max.13 digits)

(Registration)

To cancel the learing function entry
To set “auto-delete”
Unit price
(max. 6 digits)

c
When the dept. key is depressed directly

NON
DELETE

(

å
Example

Key operation

1~

99

Dept. no.
(1 - 99)

)
DEPT
#

Print

1200 3

5
8à
5 à 680 à
PLU/
2P
UPC
PLU/
PLU/
11 P
1200
UPC
UPC
P

ô
PLU/
5012345678900 P
UPC

a
Repeat entries
You can use this function for entering a sale of two or more same items.
You can use the è key to repeat entry instead of department, å, direct PLU or

Example

Key operation
Repeated
department
entry (direct)
Repeated
department entry
(indirect)
Repeated PLU
entry
(indirect)
Repeated PLU
entry
(direct)
Repeated
subdepartment
entry
Repeated UPC
entry
Repeated
department entry
(direct) using the
repeat key

PLU/
UPC

key.

Print
200 8

8
8
5 à 680 à
à
10 P
P
P
ó
ó
60 P
500 P
P
5012345678900 P
P
600 2
è
è
a
PLU/
UPC

PLU/
UPC
PLU/
UPC

PLU/
UPC

PLU/
UPC

PLU/
UPC

PLU/
UPC

PLU/
UPC

23

Multiplication entries
Use this feature when you need to enter two or more same items.
This feature helps when you sell a large quantity of items or need to enter quantities that contain decimals.

Procedure
When using a programmed
unit price
Q’ty

@

Unit price

Department key

Dept. code

à

Unit price

Dept. entry (direct)

à å
or

Dept. entry (indirect)

When [preset only dept.] is entered.
PLU code

PLU/
UPC

PLU code

PLU/
UPC

Unit price

PLU entry (indirect)
Unit price

Direct PLU key

Ä

PLU/
UPC

or

å

PLU/subdept. entry (indirect)
PLU/subdept. entry (direct)

Scan UPC code
UPC entry

UPC code

PLU/
UPC

• After scanning a UPC code or pressing the PLU/
UPC key, when the item does not exist in the file, the display will
show “NO RECORD”. Enter the unit price using the å key and department no. with the à key.
• Q’ty: Up to four digits integer + three digits decimal
• Unit price: Less than a programmed upper limit
• Q’ty × unit price: Up to seven digits

Example

Key operation
Department
entry (direct)
Department
entry
(indirect)
PLU entry
(indirect)
PLU entry
(direct)
Subdepartment
entry
UPC entry

Print

7 . 500 @
165 8
2@
5à
250 à
15 @
PLU/
13 P
UPC
8 . 250 @

ò
3@
PLU/
60 P
UPC
PLU/
100 P
UPC
5@
PLU/
5012345678900 P
UPC

a
Note

24

You must use a decimal point (.) key when entering quantities that are fractional.

Successive multiplication entries
This function may be desired when you enter a sale of items sold by area (square feet).

Procedure
When using a
programmed unit price

@

Length

Width

Dept. code

@
à

Unit price

Unit price

Department key

à å
or

Dept. entry (direct)

Dept. entry (indirect)

When [preset only dept.] is entered.
PLU code

PLU/
UPC

PLU code

PLU/
UPC

Unit price

PLU entry (indirect)
Unit price

PLU/
UPC

or

å

Direct PLU key

Ä

PLU/subdept. entry (indirect)
PLU/subdept. entry (direct)

Scan UPC code
UPC entry

UPC code

PLU/
UPC

• After scanning a UPC code or pressing the PLU/
UPC key, when the item does not exist in the file, the display will
show “NO RECORD”. Enter the unit price using the å key and department no. with the à key.
• Length or width: Up to seven digits (4-digit integer + 3-digit decimal)
• Unit price: Less than a programmed upper limit
• Length × Width × Unit price: Up to seven digits

Note

• For actual use of this function, please consult your dealer.
• You must use a decimal point (.) key when entering quantities that are fractional.

Example

Key operation

Department entry

PLU entry

Subdepartment entry

UPC entry

Print

3@
4@
400 5
1 . 500 @
2 . 500 @
PLU/
8P
UPC
1 . 750 @
1 . 750 @
PLU/
UPC
6P
PLU/
UPC
600 P
4@
5@
PLU/
UPC
5099887654302 P

a
25

Split-pricing entries
You may use this function when your customer wants to purchase items normally sold in bulk.

Procedure
When using a
programmed unit price

@

Selling q’ty

Base q’ty

@

Unit price
per base q’ty
Dept. code

Department key

à

Unit price

à å
or

When [preset only dept.] is entered.
PLU code

PLU/
UPC

PLU code

PLU/
UPC

Unit price
per base q’ty

Direct PLU key

Unit price
per base q’ty

PLU/
UPC

or

å

PLU/
UPC

or

å

Ä
UPC code

Only when you use a
base q’ty programmed
for PLU code

PLU/
UPC

PLU code

PLU/
UPC

PLU code

PLU/
UPC

Unit price
per base q’ty

Direct PLU key

Unit price
per base q’ty

Ä
UPC code

PLU/
UPC

• After scanning a UPC code or pressing the PLU/
UPC key, when the item does not exist in the file, the display will
show “NO RECORD”. Enter the unit price using the å key and department no. with the à key.
• Selling quantity: Up to four digits integer + three digits decimal
• Base quantity: Up to two digits (integer)

Example

Key operation
Department
entry

PLU entry

UPC entry

Print

7@
10 @
600 7
8@
5@
PLU/
35 P
UPC
5@
6@
PLU/
UPC
5045678912304 P

a
Note
26

You must use the decimal point (.) key when entering selling quantities that are fractional.

Single item cash sale (SICS)/single item finalize (SIF) entries
SICS entries
• This function is useful when a sale is for only one item and is for cash; such as a pack of cigarettes. This
function is applicable only to those departments that have been set for SICS or to their associated PLUs,
subdepartments or UPCs.
• The transaction is finalized and the drawer opens as soon as you press the department key, å key, PLU/
UPC key,
the direct PLU key or scanning a UPC code.

Example

Key operation

Print

250
For finishing
the transaction

Note

9

If an entry to a department, PLU/subdepartment or UPC set for SICS follows entries to
departments, PLUs/subdepartments or UPC not set for SICS, it does not finalize and results in a
normal sale.

SIF entries
• If an entry to a department, PLU/subdepartment or UPC set for SIF follows entries to departments,
PLUs/subdepartments or UPC not set for SIF, the transaction is finalized immediately as a cash sale.
• Like the SICS function, this function is available for single-item cash settlement.

Example

Key operation

Print

1745 8
1500
For finishing
the transaction

9

27

Scale entries
For making entries for weighed items, a scale may be connected where by the weight is automatically read from
the scale. To make refund or return entries, the weight is entered manually while the scale platter is empty and
reads zero.
i) Auto scale entries

Procedure

When using a
programmed unit price

When base wt. is
1 LB (or 1 KG)

Unit price
per base wt.

Dept. code

Department

à

When you use a
programmed tare no.

Tare number
(1-9)

OPEN
TARE

Unit price

à å
or

When [preset only dept.] is entered.

SCALE

Base wt.

`

Unit price
per base wt.
Dept. code

Open tare
weight

Department

à

Unit price

à å
or

When [preset only dept.] is entered.
PLU code

PLU/
UPC

PLU code

PLU/
UPC

Unit price
per base wt.

Direct PLU key

Unit price
per base wt.

PLU/
UPC

or

å

PLU/
UPC

or

å

Ä
UPC code

Only when you use a
base wt. programmed
for PLU code

PLU/
UPC

PLU code

PLU/
UPC

PLU code

PLU/
UPC

Unit price
per base wt.

Direct PLU key

Unit price
per base wt.

Ä
UPC code

PLU/
UPC

• Open tare weight: Up to 5 digits (integer + decimal)
• Net weight:
Up to 5 digits (integer + decimal)
• Base weight:
Up to 2 digits (integer)

Note

• The register can be programmed with up to nine tare tables and allows different tares to be
assigned to them.
• When the S key is pressed, the weight is automatically read from the connected scale (option)
and the net weight appears in the register display.
• When the item is programmed for “Scale compulsory”, it is not necessary to press the S key.

Example
Key operation

S 200 1
S1P
c
PLU/
UPC

28

Print

ii) Manual scale entries of refunded items

Procedure

When using a
programmed unit price

When base wt. is
1 LB (or 1 KG)

Unit price
per base wt.
Dept. code

Department

à

Unit price

à å
or

When [preset only dept.] is entered.
Net weight

Ï
RETERN
Ï

SCALE

Base wt.

`

Unit price
per base wt.
Dept. code

Department

à

Unit price

à å
or

When [preset only dept.] is entered.
PLU code

PLU/
UPC

PLU code

PLU/
UPC

Unit price
per base wt.

Direct PLU key

Unit price
per base wt.

PLU/
UPC

or

å

PLU/
UPC

or

å

Ä
UPC code

Only when you use a
base wt. programmed
for PLU code

PLU/
UPC

PLU code

PLU/
UPC

PLU code

PLU/
UPC

Unit price
per base wt.

Direct PLU key

Unit price
per base wt.

Ä
UPC code

PLU/
UPC

• Net weight: Up to 5 digits (integer + decimal) which is from the customer’s receipt.
• Base weight: Up to 2 digits (integer)

Example
Key operation

Print

32 . 85 Ï S 200 1
PLU/
37 . 25 Ï S 1 P
UPC

c

29

PLU level shift (for direct PLU)
This shift function can allow access to PLUs on your register without adding additional direct PLU keys. You can
use direct PLUs in five levels by utilizing PLU level shift keys l thru L5 . The level shift key shifts the PLU
level from the other four to the required level. (The normal level is level 1.) You can also shift PLU level by
entering a level number and pressing the PLU level shift number key, ä.
You must program your machine in the PGM2 mode to select one of the two PLU level shift modes — automatic
return mode* and lock shift mode** — and decide whether to allow PLU level shift in both the REG and MGR
modes or in the MGR mode alone.
* The automatic return mode automatically shifts the PLU level back to level 1 after a direct PLU key is pressed.
You can select whether the PLU level should return each time you enter one item or each time you finalize
one transaction.
** The lock shift mode holds the current PLU level until a PLU level shift key is pressed.
Automatic return mode (for PLU levels)
If you shift the PLU level while in the automatic return mode, press the desired PLU level shift key before
numeric entries.

Procedure
• each item

¬

thru

L5
Numeric entry

Level no.
(1 to 5)

ä

@

(Q’ty,

Direct PLU

(Returning to level 1)

Direct PLU

Payment

)

• each transaction

¬

thru

L5
Numeric entry

Level no.
(1 to 5)

ä

(Q’ty,

@

(Returning to level 1)

)

Lock shift mode (for PLU levels)
If you shift the PLU level while in the lock shift mode, press the desired PLU level shift key before numeric
entries.

Procedure
To shift the level of another PLU

l

thru

Level no.
(1 to 5)

Note

30

L5
Numeric entry

ä

(Q’ty,

@

Direct PLU

(Staying in the current level)

)

If you select the automatic return mode, it is not necessary to use the l key on the keyboard, but
if you select the lock shift mode, it is necessary to use the key.

Example

Direct PLU1: PLU code 1 (PLU level 1), PLU code 65 (PLU level 2)
Direct PLU2: PLU code 2 (PLU level 1), PLU code 66 (PLU level 2)

• When your machine has been programmed for the automatic return mode:
Key operation

Print

1
¬1
2
1
a
• When your machine has been programmed for the lock shift mode:
Key operation

Print

l1
¬1
2
1
a

31

PLU/UPC price level shift
Six different price level shifts can be programmed for each PLU or UPC.
The price levels can be changed for PLU or UPC registrations.
You can change a PLU/UPC price among six prices by utilizing the price level shift keys P1 thru P6 , the level
shift key shifts the price level from the other five to the required level. (The normal level is level 1.) You can
also a shift price level by entering level number and pressing the price level shift number key, ¥.
You must program the price level shift mode (i.e. automatic return mode* or lock shift mode**) and the operating
mode to be used for the price level shift (i.e. both REG/MGR modes or MGR mode alone).
* The automatic return mode automatically shifts the PLU/UPC price level back to level 1 after a PLU/UPC shift
entry. You can select whether the price level should return each time you enter one item or each time you
finalize one transaction.
** The lock shift mode holds the current PLU/UPC price level until pressing the price level shift key.
Automatic return mode (for price levels)
If your register has been programmed for the price level shift in the automatic return mode, press a desired price
level shift key before a numeric type entry.

Procedure
(each item)

Ä

P2 thru P6
Numeric entry
Level no.
(1 to 6)

¥

(Q ty,

@

PLU/UPC code

PLU/
UPC

etc.)

(Returning to
price level 1)

Direct PLU

(each transaction)

Ä

P2 thru P6
Numeric entry
Level no.
(1 to 6)

¥

(Q ty,

@

PLU/UPC code

PLU/
UPC

Payment

etc.)
Direct PLU

(Returning to
price level 1)

Lock shift mode (for price levels)
If your register has been programmed for the price level shift in the lock shift mode, press a desired price level
shift key before a numeric type entry.

Procedure
To shift the price level of another PLU/UPC

Ä

P1 thru P6
Numeric entry
Level no.
(1 to 6)

Note

32

¥

(Q ty,

@

PLU/UPC code

etc.)

PLU/
UPC

Direct PLU

• If you select the automatic return mode, it is not necessary to use the P1 key on the keyboard,
but if you select the lock shift mode, it is necessary to use the key.
• You can program “printing of the price level text. Please refer to “Programming for optional feature
selection” described in the “PROGRAMMING” section of this manual.

Example

PLU price level 1: PLU 1 ($1.91), PLU 2 ($0.79)
PLU price level 2: PLU 1 ($2.00), PLU 2 ($0.99)
• When your register has been programmed for the automatic return mode (by one item):
Key operation

P2

Print

PLU/
1P
UPC
PLU/
1P
UPC
PLU/
2P
UPC

a

• When your register has been programmed for the lock shift mode:
Key operation

Print

UPC
1P
PLU/
UPC
1P
PLU/
UPC
2P
PLU/

P2

a

Set PLU entries
Operations are the same as normal PLU’s.
When a set PLU is entered, an entered or preset amount is printed as the unit price and then those PLUs linked
to the set PLU are printed automatically.

Example
Key operation

Print

p
a

Note

The unit price of the set PLU (ex. PLU 20) is the registered amount of the set PLU. The tied PLU’s
memory is updated only by the entered quantity.

33

Link PLU/UPC entries
The operation is the same as normal PLU’s/UPC’s. When this PLU/UPC is entered, the linked PLU’s amount is
included and the linked PLU’s label is printed automatically. Only the 1st PLU is affected by the status shift keys
TAX
( SHIFT
, |, «, » or ˛ key). The percent calculation is in effect for the amount of the 1st ranking PLU.

Example

When PLU 21 is linking PLU 25,26,27 as follows
Key operation

Print

PLU/
UPC
21 P

a

Age verification (Birthday entry)
The age verification function is used for prohibiting the sale of goods (departments, PLUs or UPCs) for certain
aged persons based on a registered birthday.
When a department/PLU/UPC for which a figure other than zero (01 to 99) has been programmed as the age
limitation is entered, a birthday entry must be completed.

Procedure
XXXXXX

BIRTH

Birthday (five or six digits)

Note

• A birthday entry can be performed two or more times at any point during a transaction, however
the last entered birthday remains in effect.
• You can enter the date as far back as 98 years.
[Ex.] When the current year is 2005 : you can enter the year 1907-2005.

Example

Oct. 2, 1985 (When dept. 7 is programmed as the age limitation “17”.)
Key operation

Print

100285 BIRTH
7
300 7

a
When birthday printing is allowed, through programming (Job no. 2616), the birthday date is printed.

34

Mix-and-match entries
This function is convenient for matching several PLU/UPC items and selling them in a lump (e.g. bundle sale,
multi-packed sale, etc.). The matching q’ty and adjusted amount are assigned to a mix-and-match table. All
items that are programmed into the same table are treated as if they belong to one group.

Example

Selling on a mix-and-match basis the following items in table no. 1 to which the matching q’ty
“3” and the adjusted amount “$10.00” are assigned:
• PLU 40 (Unit price: $5.00)
• PLU 41 (Unit price: $3.00)
• PLU 42 (Unit price: $2.50)
Key operation

Print

Treated as $5.00 item ➝ /
Treated as $3.00 item ➝ !
Treated as $2.00 item ➝ @

a

Condiment entries (for PLUs)
Your register may be programmed for prompting condiment and preparatory instructions for a menu-item PLU.
Example:
When you enter a menu-item PLU, a prompting message such as “HOWCOOK?” will appear. You must specify
a PLU such as “RARE” to meet a special order of the guest.
In an example of the condiment table show below, it is assumed the condiment table #1 and #4 is assigned to
PLU 210 (item label: STEAK/unit price: $13:00).
When you enter PLU 210, the message “HOWCOOK?” will appear. You are allowed to enter one of the PLU
code, 221, 222 and 223. When you enter PLU 221, “RARE” is registered and the next message “POTATO?” will
appear. When you enter PLU 226, “P.CHIPS” is registered. Then press the a key to end this entry.
Table number

PLU codes for condiment entry (programmed text, price)

1

220
(HOWCOOK?)

221
(RARE 0.00)

222
(MED.RARE 0.00)

223
(WELLDONE 0.00)

4

225
(POTATO?)

226
(P. CHIPS 0.60)

227
(MASHED.P 0.60)

228
(BAKED.P 0.50)

Menu-item PLUs
(PLU210 is linked
to table #1)

Example

Message text

Next table no.
4

Condiment PLUs (preset price entry is allowed.)

Key operation

Print
210

P

221

P

226

P
c

PLU/
UPC

“HOWCOOK?” appears.
PLU/
UPC

“POTATO?” appears.
PLU/
UPC

35

• Your register will continue to prompt for the condiment entry until you finish the entire condiment
entry programmed for the PLU. During the condiment entry, if you enter a normal PLU, which is
not in the condiment table, an error message will appear in case the condiment entry is
compulsory.
C
• When the NEXT
key is pressed, the entry skips to the next table which is programmed.
C
• When the CANCEL
key is pressed, its condiment entry is canceled in the programmed mode
(REG/MGR or MGR).
• When you enter a PLU priced at “0.00,” only the text will be printed on the receipt.
• No refund entry is possible for any condiment entries. When you perform a refund entry with a
menu-item PLU and the condiment PLUs assigned to the menu-item PLU are automatically
registered as a refund entry.
C
• You may omit the compulsory condiment entry by pressing the NEXT
key.

Note

Price inquiry (view) function (for PLU/UPCs)
You can use this function when you want to know the unit price of the PLU/UPC item during sales transactions
while in the REG/MGR mode.

Procedure
"VIEW" is displayed.

Numeric entry

Ù

(Q'ty

`

)
The total sales amount of
the PLU/UPC is displayed.

Scan UPC code

Ä
UPC code

*1

PLU/
UPC

c
å
*2

PLU code

PLU/
UPC

PLU/ or
UPC

Unit price

å

*3
(MGR mode) Unit price
Unit price

Direct PLU

å

*1: Press the c key to cancel the inquiring (view) mode.
*2: Press the å key when you want to register the unit price of the PLU/UPC displayed.
*3: You can change the unit price temporarily in the MGR mode. The unit price which is programmed in PGM
mode is not changed (Price override entry).
For the repeat entry, use the è key.

Note
Example

Key operation

Print

P
Ù
5089123456708 P
å
c
5

Price is displayed.

36

PLU/
UPC

PLU/
UPC

UPC learning function
When you enter or scan an undefined code, you are required to enter the unit price “amount” and the associated
department. The UPC code, unit price and the department entered are stored in the dynamic UPC file (if
opened, and if not opened, in the PLU/UPC file) and is used for future sales entries.

Note

• When there is no capacity remaining in the file, the data is not stored in the file.
• The text of the entered department is applied to the entered UPC code.
• You can use the UPC learning function in the training mode. This may be convenient to practice
when installing the scanning system.

Procedure
"NO RECORD" is displayed and the beep sound occurs three times.
Then, "PRICE -> DEPT" is displayed to guide you to enter unit price
and associated department code.
Scan an undefined UPC code

Ä
Undifined
UPC code

When the unit price is zero, or in case of
non-PLU type UPC code having price info.
or press code.
*

PLU/
UPC

Ì

Unit price

Department key

å

c

Dept. no.

à

To cancel the operation
"ENTER DEPT#"
is displayed

* Press the Ì key when you want to exempt the UPC code entered from the non-accessed UPC delete
function (deletion occurs by executing #105 in Z1 mode).

Note

For the repeat entry, use the è key.

Example
“NO RECORD”, “PRICE ->
DEPT” are displayed.

Key operation

Print

PLU/
5056789123404 Û
UPC
750

5
c

37

Price change function (for PLU/UPCs)
You can use this function when you need to change the unit price or associated department of a PLU/UPC item
in REG/MGR mode.
There are two methods for price changes:
1. Price change mode
You can change the preset price and/or the associated department of a PLU/UPC item without entering PGM
mode.
2. Changing a price during a transaction
When a wrong PLU/UPC price and/or associated department is found during transaction, you can correct
them at the time of the transaction. With the entry of a new price and/or associated department, the preset
price and/or associated department is automatically changed to the new price and/or associated department.

Note

For the Non-PLU type price embedded UPC-A codes, the prices in the codes have the priority over
the preset prices. So, for these codes, a changed price is valid only when the price change is
executed.

Procedure
Price change mode
"PRICE CHANGE" is displayed.
Scan UPC code

Ä
Ê

UPC code

PLU/
UPC

PLU code

PLU/
UPC

Direct PLU

Changing a price during a transaction
Scan UPC code

Ä
UPC code

PLU code

Ê

PLU/
UPC

PLU/
UPC

Unit price

PLU/ or
UPC

Unit price

"PRICE & DEPT" is displayed.

å

Direct PLU

Ê

To change the unit price only

To enter 0
Unit price

c
To cancel

To change the associated dept.
directly by depressing the
corresponding key

Department key

å

Dept no.

à

"ENTER DEPT#" is displayed.

38

To change the associated dept.
using the dept. no. entry key

Example
• Price change mode
Key operation

Print

Ê
PLU/
5087654321106 Û
UPC
600 Ê

• Changing a price during a transaction
Key operation

Print

UPC
5087654321106 Û
PLU/

Ê
600 Ê

c

The journal printer prints the
following format in this position.

Associated dept. no.

Note

• When an undefined code is entered in the price change mode, the register results in an error.
• When you press the Ê key during a transaction, the UPC entry is voided upon the 1st
depression of the Ê key, then you are allowed to enter a correct price and/or associated
department.
• In case the item label of the UPC is the same as the associated department, the item label is
changed to the item label of the new associated department when the associated department is
changed.
• For the repeat entry, use the è key.

39

2 Displaying and printing subtotals
Your register provides these five types of subtotals:

Merchandise subtotal
Press the  key at any point during a transaction. The net sale subtotal - not including tax - will appear in the
display.

Taxable subtotal
Taxable 1 subtotal
TAX
Press the SHIFT
(') and ı keys in this order at any point during a transaction. The sale subtotal of
taxable 1 items will appear in the display.
Taxable 2 subtotal
Press the | and ı keys in this order at any point during a transaction. The sale subtotal of taxable 2
items will appear in the display.
Taxable 3 subtotal
Press the « and ı keys in this order at any point during a transaction. The sale subtotal of taxable 3
items will appear in the display.
Taxable 4 subtotal
Press the » and ı keys in this order at any point during a transaction. The sale subtotal of taxable 4
items will appear in the display.

Including-tax subtotal (full subtotal)
Press the ı key at any point during a transaction. The sale subtotal including tax will appear in the display.

Food stamp-eligible subtotal
Press the f key at any point during a transaction. The sale subtotal of items eligible for food stamp payment
will appear in the display.

Tray subtotal
Press the y key during a transaction in the REG or MGR mode.
The contents of the tray total itemizer which include tax are printed and displayed.

Eat-in subtotal
You may press an eat-in key prior to entering a payment. Your register will calculate a subtotal according to the
programmed tax exemption status and display the subtotal, the symbol “EAT IN,” and a corresponding caption
(“EAT IN 1,” “EAT IN 2,” or “EAT IN 3”).
For the transaction with the eat-in subtotal, you must finalize the transaction by making a payment entry.
Just after pressing the eat-in key, however, you can cancel the entry of that key by pressing the c key or
another eat-in function key.

Gasoline discount subtotal
Use the following procedure to get a gasoline discount subtotal; amount after gas discount amount is deducted.
The gasoline discount subtotal will appear in the display.
Number of media to be used for finalization*
(1-19)

40

GAS
SBTL

*:

a:1
Å:2
Å3 : 3
Å4 : 4
É:5

k:6
CHK2 : 7
k
CHK3 : 8
k
CHK4 : 9
k
CHK5 : 10
k

( : 11
) : 12
* : 13
+ : 14
, : 15

,6 : 16
,7 : 17
,8 : 18
,9 : 19

3 Finalization of transaction
Cash or Check tendering
Press the ı key to get an including-tax subtotal, enter the amount tendered by your customer, then press the
a or one of the Å thru É keys if it is a cash tender or press the k or one of the CHK2 thru CHK5 key if it is a
check tender. When the amount tendered is greater than the amount of the sale, your register will show the
change due amount and the text “CHANGE”. Otherwise your register will show the text “DUE” and a deficit.
Make a correct tender entry.

Example

Your customer pays $10.00 for an including-tax subtotal of $7.35.

Cash tendering
Key operation

Print

ı
1000 a

Check tendering
Key operation

Print

ı
1000 k

Mixed tendering (check + cash)
Example

Your customer pays $10.00 by check and $5.00 in cash for an including-tax subtotal of $14.56.
Key operation

Print

ı
1000 k
500 a

41

Cash or Check sale that does not need any tender entry
Enter items and press the a or one of the Å thru É keys if it is a cash sale or press the k or one of the
CHK2 thru CHK5 keys if it is a check sale. Your register will display the total sale amount.

Example

Selling a $3.00 item (dept. 6) and another $7.15 item (PLU 10) for cash
Key operation

Print

300 6
PLU/
10 P
UPC

a
In the case of check 1 sale

Charge (credit) sale
Enter items and press the corresponding charge keys (h thru

Example

CH9

).

Selling a $25.00 item (dept. 5) and a $32.50 item (dept. 6) and accepting the payment by
charge 1 account
Key operation

Print

2500 5
3250 6

h
Amount tendering operations (i.e., change calculations) can be achieved by the h thru
been preset in PGM2 job #2320.

CH9

key when it has

Mixed-tender sale (cash or check tendering + charge tendering)
Example

Your customer pays $9.50 in cash and $40.00 by charge 1 for an including-tax subtotal of
$49.50.
Key operation

ı
950 a

h

42

Print

4 Food stamp calculations
Food stamp tendering
If your customer makes payment (or tendering) in food stamps, obtain the food stamp-eligible subtotal* by
pressing the f key and make a food stamp tender entry before entering a cash or check tender.

Note

The food stamp-eligible subtotal* depends upon how your register is programmed based on the
food stamp-eligibility of the automatic tax on a sale of items eligible for food stamp payment, or
whether your register is programmed to allow the automatic tax to be paid with food stamps or not
or to exempt taxation. The example below presupposes that your register has been programmed
to exempt taxation.

When the amount tendered in food stamps is greater than the food stamp-eligible subtotal:
Your register shows two change due amounts in its display.
The food stamp change due appears at the left of the display in dollars and the cash change at the right in cents.
• When you enter only items eligible for food stamp payment.

Example

Your customer purchases a $4.25 item (dept.4, taxable 1, eligible for food stamp payment)
and another $4.00 item (PLU 34, taxable 2, eligible for food stamp payment) and tenders
$10.00 food stamps for them.
Key operation

Print

425 4
34 P
UPC

To display
the food
stamp-eligible
subtotal

f
1000 f
Food stamp
change due
Cash change
due

Display shows:

Food stamp
change

Cash
change

• Mixed sale of an item eligible for food stamps and another item not eligible for food stamps

Example

Your customer purchases a $2.48 item (dept. 5, taxable 1, eligible for food stamps) and
another $5.42 item (dept. 8, nontaxable, ineligible for food stamps) and pays $5.00 in food
stamps and $5.00 in cash.
Key operation

Print

248 5
542 8

f
500 f
500 a
Food stamp
change due

Display shows:
Cash change
due

Food stamp
change

Cash
change

43

When the food stamp tender is smaller than the food stamp-eligible subtotal:
• Accept the remainder in food stamps or in cash or check. If your register is programmed to exempt taxation,
additional food stamp tender is not allowed.

Example

Your customer buys a $3.18 item (dept. 5, taxable 1, eligible for food stamps) and another
$1.24 item (dept.7, taxable 2, eligible for food stamps) and pays $4.00 in food stamps and the
remainder - $1.00 in cash.
Key operation

Print

318 5
124 7

f
To enter the
cash tendering
of the remainder

400 f
100 a

Food stamp status shift
Your machine allows you to shift the programmed food-stamp status of each department, PLU/UPC or - thru
±, percent key by pressing the ˛ key prior to those keys. After each entry is completed, the programmed
food stamp status is resumed.

Example

You sell a $2.32 item of dept. 2 (food-stamp eligible) as a food-stamp ineligible item and
another $3.18 item of PLU 86 (food-stamp ineligible) as a food-stamp eligible item and accept
$4.00 in food stamps and $2.00 in cash.
Key operation

232 ˛ 2
PLU/
86 ˛ P
UPC

f
400 f
200 a

44

Print

5 Tax calculations
Automatic tax
When your register is programmed with a tax table (or tax rate) and the tax status of an individual department
and PLU/UPC is set for taxable, it computes the automatic tax on any item that is entered directly into the
department or indirectly via a related PLU/UPC.

Example

Selling five $6.70 items (dept. 1, taxable 1) and one $7.15 item (PLU 85, taxable 2) for cash
Key operation

Print

5@
670 1
PLU/
85 P
UPC

a

Manual tax
Your machine allows you to enter tax manually after item entries.

Example

Selling an $8.00 item (dept. 7) for cash with 50 cents as tax
Key operation

Print

800 7
50 †

a

45

Automatic-tax delete
You can delete the automatic tax on the taxable 1, taxable 2, taxable 3 and taxable 4 subtotal of each
transaction by pressing the † key after the subtotal is displayed.

Example

Selling a $7.25 item (dept. 1, taxable 1) and another $5.15 item (dept. 3, taxable 2) for cash
and entering the sale as a non-taxable one
Key operation

Print

725 1
515 3
*\ı
TAX
SHIFT

TAX1
* SHIFT
for ER-A530

†
|ı
†
a

If any of the media keys (i.e. cash, check or charge 1 thru charge 5) are programmed as tax delete in PGM2
mode, the tax can be deleted without using the procedures above. In this case, depressing a corresponding
media key alone will always cause the programmed tax to be deleted.

Example

When the Å key is programmed as tax delete for the same case with the above example
Key operation

725 1
515 3

Å

46

Print

Tax status shift
Your machine allows you to shift the programmed tax status of each department, - thru ≠, percent key or
TAX
TAX1
the PLU/UPC key by pressing the SHIFT
( SHIFT
), |, « and/or » keys before those keys. After each entry is
completed, the programmed tax status of each key is resumed.

Example

Selling the following items for cash with their programmed tax status reversed
• One $13.45 item of dept. 7 (non-taxable) as a taxable 1 item
• One $7.00 item of dept. 2 (non-taxable) as a taxable 1 and 2 item
• One $4.00 item of dept. 3 (taxable 2) as a non-taxable item
• Two $10.50 items of dept. 1 (taxable 1) as taxable 2 items
Key operation

Print

1345 \ 7
700 \ | 2
400 | 3
1050 \ | 1
TAX
SHIFT

TAX
SHIFT

TAX
SHIFT

1
a

Note

The entry of a multi-taxable item for PST or GST will be prohibited as follows (for Canada).
In case of; Tax 1: PST, Tax 2: PST,
Tax 3: PST, Tax 4: GST
Taxable 1 and 2 item ········· prohibited
Taxable 1 and 3 item ········· prohibited
Taxable 2 and 3 item ········· prohibited
Taxable 1 and 4 item ············· allowed
Taxable 2 and 4 item ············· allowed
Taxable 3 and 4 item ············· allowed

In case of; Tax 1: PST, Tax 2: PST,
Tax 3: GST, Tax 4: GST
Taxable 1 and 2 item ········· prohibited
Taxable 1 and 3 item ············· allowed
Taxable 2 and 3 item ············· allowed
Taxable 1 and 4 item ············· allowed
Taxable 2 and 4 item ············· allowed
Taxable 3 and 4 item ········· prohibited

47

6 Guest Check (GLU/PBLU)
Note

Please note that the previous balance key (ufor ER-A520 and

PBAL

for ER-A530) is shown as u.

Two different guest check entry systems are available: the GLU system and previous balance lookup (PBLU)
system. It depends on how your register has been programmed which of these is used. Please contact your
authorized SHARP dealer for more information about this selection.
GLU system:
If this system is selected, the balance due and the details of the order are placed in the guest
GLU
check file. The information can be automatically recalled by pressing the RECALL
key, or enteringa
GLU code when additional ordering or finalization is required.
PBLU system: If this system is selected, the previous balance is stored in the previous balance lookup file
(PB lookup file). The information can be automatically recalled by entering a previous balance
lookup code (a PBLU code) when additional ordering occurs.

GLU/PBLU system
New guest
For a new guest;

Procedure
For automatic GLU/PBLU
code generation
GLU/PBLU code
(1-9999)

n

Cover count entry

[Item entries]

Partial tendering
Amount

Note

48

r or A

S
f
[Payment operations]

Ω
∏

• The GLU/PBLU code refers to a number/code that will be used whenever the guest check must be
accessed for re-ordering or final payment.
• The available range of GLU or PBLU codes can be programmed for each chashier/server.
• Your register can be programmed to generate GLU/PBLU codes in a sequential fashion. If your
register has not been programmed to do so, each GLU/PBLU code can be entered manually.
• The cover count refers to the number of people in the party. When the cover count entry is
compulsory, you must enter the cover count (max. 2 digits). When cover count is not compulsory,
CV
enter the cover count and press the CNT key.
• When the S key is pressed, the tax is not calculated.
• You can temporarily finalize a guest check by pressing the f key. In the GLU system the check
will show the current balance including tax while the tax amount is not added to the GLU/PBLU
file, and when an additional order is made, the tax amount is recalculated. In the PBLU system,
the check will show the current balance including tax and the tax amount is added to the
GLU/PBLU file (charge posting), while the guest check is still open.

Example
Key operation

Print

111 n
CV
22
CNT
3500 2
2700 3

f

Not printed when the

S key is
f key.

pressed instead of the

GLU recall
GLU
Each cashier/server can recall their GLU/PBLUs for reorder or settlement by pressing the RECALL
key. The register
display GLU/PBLUs from the smallest GLU/PBLU number. Follow the procedure to recall GLUs and select a
desired GLU/PBLU code.

Procedure

GLU
RECALL

A GLU/PBLU code and the total
amount are displayed.

#/
TM

:To go to the following GLU/PBLU*

u

:To select

L

:To cancel GLU recall

GLU/PBLU
code

* When the largest opened GLU/PBLU number is displayed, the smallest GLU/PBLU number is displayed when
#/
the TM
key is pressed.

Example

Opened GLU: #111/#112/#113
Selecting GLU#113 and making sales entry of two dept. 7 items ($3.00 and #5.00)
Key operation

Print

GLU
RECALL
#/
TM

Get ready for sales entry

#/
TM

u
300 7
500 7

f

49

Reorder entries
For making additional guest check entries, use the following procedure:

Procedure
GLU/PBLU code
(1-9999)

u

[Item entries]

Partial tendering
Amount

r or A

S
f
[Payment operations]

Ω
∏

Example
Key operation

Print

111 u
1400 5
1600 6
3000 r

c

Settlement
Use the following procedure:

Procedure

GLU/PBLU code
(1-9999)

u

[Item entries]

Ω
∏

[Payment operations]

Example
Key operation

Print

111 u
5000 k
2000 c

Note

50

• You can make a tip-in entry before a tender entry. If a tip-in entry is made, the tip amount must be
tendered by using the associated media key e.g. CH1 thru CH9 for the charge tip and CASH 1 or
CASH 5 for the cash tip.
• Partial tendering is prohibited after tip-in entry operation.

Deposit entries
Deposit refers to a payment on a charge account. It can be received in cash, check or by charge. You can make
the deposit entry only while in a guest check transaction. It cannot be done during handling of a tendered
amount.
A received deposit can be refunded by pressing the DEPO
RFND key. You cannot attempt to refund an amount larger
than the deposit balance.

Procedure

DEPO
Deposit
amount
DEPO
RFND

Example

k
c
h

thru

CHK5

thru

É

thru

CH9

To record a $50.00 deposit in cash made by a customer with PBLU code 111
Key operation

Print

111 u
DEPO
5000 5

Å
S

Example

To refund a $50.00 deposit made by a customer with PBLU code 111
Key operation

Print

111 u
DEPO
5000 5
RFND

Å
S

51

Transferring guest checks out or in (Transfer-out/in)
Transferring guest checks out
At the end of a cashier/server shift or whenever a cashier/server is relieved, one or more open guest checks can
be transferred from the cashier/server to the open check file until the responsibility for the check(s) is assigned
to another cashier/server.

Procedure
(cashier/server sign-on)

’

GLU/PBLU code
(1-9999)

u

’

For the next guest check

Example

GLU#111 is transferred out.
Key operation

Print

’
111 u

’

Transferring guest checks in
When the second cashier/server is assigned to be responsible for guest checks that have been transferred out:

Procedure
Only when cover count entry is non-compulsory
(new cashier/server
sign-on)

”

GLU/PBLU code
(1-9999)

u

Cover count entry
(2 digits)

For the next guest check

Example

GLU#111 is transferred in.
Key operation

”
111 u

”

52

Print

CV
CNT

”

Bill totalizing/bill transfer
Bill totalizing
The bill totalizing function is used to totalize multiple bills when, for example, a particular guest pays not only his
or her bill, but also the bills of other guests.

Procedure

j

GLU/PBLU code

u

GLU/PBLU code

#1 bill

s

#2 bill

[Sales entries]

S
f
[Payment operations]

Example

Totalizing GLU#112 and GLU#113 to GLU#111
Key operation

Print

j
112 u
113 u
111 s

S

Note

• All #1 bills are added to a #2 bill. A maximum of 5 bills may be added to a #2 bill.
• The GLU/PBLU code of #1 must be in use. If the guest check(s) of #1 or #2 has already been
handled by another server, the guest check(s) must have been made “Transferring out.”

53

Bill transfer
This function is used to change the GLU/PBLU code of a particular bill.

Procedure

j

GLU/PBLU code

u

GLU/PBLU code

#1 bill

s

#2 bill

S
f

[Sales entries]

[Payment operations]

Example

GLU#111 is transferred to GLU #120.
Key operation

Print

j
111 u
120 s

S

Note

• This function requires that the current GLU/PBLU code be entered for #1 and a new GLU/PBLU
code be entered for #2.
• A #1 bill is transferred to a #2 bill. The #1 bill is then cleared and set free.

Bill separating
The function is used when each guest of a group pays his or her own order. With this function, you can select
some items from a guest check and make an entry for the payment. Also, you can transfer the items you have
selected to other guest checks. This function is available only in the GLU system.

Procedure
To terminate

b

An item of the original GLU
and its quantity are displayed.
To go to the following item

b

GLU code
(Original GLU code)

u

GLU code
(For receiving)

u

#/
TM

To enter total q'ty
Q'ty

@
To terminate

S
f
[Payment operations]

54

b

Example

One of the dept. 9 items is separated from GLU111 (three dept. 7 items and three dept. 9
items are entered.)
Key operation

Print

b
111 u
117 u
Dept. 7 item label and the q’ty are displayed.
#/
TM

To skip dept. 7 items
Dept. 9 item label and the q’ty are displayed.

1@

To select one of dept. 9 items

S
b

Manual Previous Balance (PB) and Credit Balance (CB) entry
The register allows you to make manual PB/CB entries. If you use this function, the previous balance amount is
entered manually when making new entries that will adjust the original total.
This function is not available when you use GLU or PBLU system. To use this function, please
contact your authorized SHARP dealer.

Note

New customers
For a new customer, use the following procedure:

Procedure

n

[Item entries]

Note

Example

S f
or

When the S or f key is pressed, the tax is automatically calculated and printed. The tax is then
added to the balance and the new balance is printed.

Making a service entry for a dept. 5 item ($87.50) and a dept. 6 item ($62.50) item for a new
customer. (A non-add code is used to identify the customer.)
Key operation

Print

n
#/
13579 u
TM
8750 5
6250 6

S

55

Customer with previous or credit balance
To enter a charge to a customer with a previous or credit balance, use the following procedure:

Procedure
Check digit*1
(Optional)

u
n

Previous balance*2
Charge balance*3

[Item entries ]

S f
or

*1 Check digit: The number which is printed at the right of the word “SERVICE” on the receipt of the previous
entry. (See the previous page. Check with your authorized SHARP dealer for activation of the
check digit feature.)
*2 Previous balance: In case of the balance is plus or zero
*3 Charge balance: In case of the balance is negative

Example

To make a service entry of 5 dept 7 items (unit price $25.00) for the customer account from
the previous example. (non add code number 13579), which has the previous balance
$150.00.
Key operation

Print

3 15000 u
#/
13579 5
TM
5@
2500 7

Check digit

S

Settlement
Use the following procedure:

Procedure
Check digit
(Optional)

Previous balance
Charge balance

Example

u
n

[Payment operation]

The customer (the non add code number 13579) whose previous balance is $275.00 is
$27500 pays $200.00 in check and $75.00 in cash.
Key operation

Check digit

56

[Item entries ]

3 27500 u
#/
13579 5
TM
20000 k
7500 a

Print

7 Auxiliary entries
Percent calculations (premium or discount)
• Your register provides the percent calculation for the merchandise subtotal and item entries. You need to
specify in advance whether the register should perform the percent calculation based on the merchandise
subtotal or each item entered.
• Percentage: 0.01 to 99.99%
Percent calculation for the merchandise subtotal

Example

Selling four $1.40 items of dept. 5 and two $2.25 items of dept. 6; all these items are sold for
cash at a premium of 10%
(This example presumes that a premium of 10% has been programmed for the % key.)
Key operation

Print

4@
140 5
225 6

6
Â
%
a

Percent calculation for item entries

Example

Selling for cash an $8.00 item of dept. 6 at a discount of 15% and another $5.00 item of PLU
90 at a discount of 7.5%
(This example presumes that a discount of 15% has been programmed for the § key.)
Key operation

Print

800 6

§
PLU/
90 P
UPC
7.5§

a

57

Discount entries
For discount or coupon tenderings, you may use the - thru ± key.
If the discount or tendered coupon is the one applicable to sales, use the vendor coupon or if it is applicable to
each department key, use the store coupon.
Discount for the merchandise subtotal

Example

Selling a $5.75 item of dept. 6 and another $7.50 item of PLU 80 for cash after subtracting the
discount amount $1.00 from the total sale amount
(This example presumes that the vendor coupon has been programmed for the – key.)
Key operation

Print

575 6
PLU/
UPC
80 P
100 –

a
Discount for item entries

Procedure

Amount

Dept. code
PLU code
UPC code

Example

Dept.

- ±
thru

-

thru
thru
thru
thru

Direct PLU

±
±
±
±

à

Amount

PLU/
UPC

Amount

à å
å
or

PLU/
UPC

or

PLU/
UPC

Ä

Selling a $6.75 item of dept. 5 for cash after subtracting the coupon amount 75¢
(This example presumes that the store coupon has been programmed for the - key.)
Key operation

Print

675 5
75 -

*

Note

58

*

5
a

The - is entered as a modifier for the department which will be netted by the coupon amount.
Such item netting coupon entries may generally be entered at any point within a transaction. Two
lines are printed for each entry: The first is the label programmed for the - function and the
second is related department and - amount.

Refund entries
If a refund item is the one entered into a department, enter the amount of the refund, then press the Ï key and
the corresponding department key in this order; and if an item entered into a PLU (or UPC) is returned, enter the
UPC
corresponding PLU (or UPC) code, then press the Ï and PLU/
keys, or press the Ï and direct PLU keys
without entry of PLU code, in this order.

Example

Receiving the following items returned:
One $2.50 item of dept.5 and seven $2.10 items of PLU 13
Key operation

Print

250 Ï 5
7@
PLU/
13 Ï P
UPC

a

Return entries
If a return item is the one entered into a department, enter the amount of the return, then press the RETURN key and
the corresponding department key in this order; and if an item entered into a PLU (or UPC) is returned, enter the
UPC
corresponding PLU (or UPC) code, then press the RETURN and PLU/
keys, or press the RETURN and direct PLU keys
without entry of PLU code, in this order.

Example

Receiving the following items returned:
One $3.00 item of dept 1 and one $3.25 item of PLU15
Key operation

Print

RETURN 1
300 Ï
RETURN t
15 Ï
PLU/
UPC

a

Note

The returned items are not subjected to the calculation for dept./PLU/UPC items (quantity and
amount) on the sales reports.

59

Refund sales mode
This function is used for those item return entries relating to departments, PLUs/subdepartments and UPCs.
Pressing the ˜ key at the beginning of a transaction causes the register to enter the REFUND SALES mode.
All of the REFUND SALES mode entries are automatically handled as refund entries. This mode cannot be
finalized by check payment entry.

Example

Receiving the following items returned:
One $2.50 item of dept.5 and seven $2.10 items of PLU 13
Key operation

Print

˜
250 5
7@
PLU/
13 P
UPC

a

Printing of non-add code numbers
Enter a non-add code number such as a customer’s reference number within a maximum of 16 digits and press
#/
the TM
key at any point during the entry of a sale. Your register will print it at the time of entry.

Example

Selling a $15.00 item of dept. 5 by charge account to a customer whose code number is 1230
Key operation

1230 =
1500 5
#/
TM

h

60

Print

Gratuity
Calculation
When the payment operation is made for sales registrations, the gratuity amount is calculated and printed.
You can program a percent rate for calculating the gratuity.
If the percent rate is programmed as 0%, the register does not print any gratuity.
You can program a tax status (taxable 1/taxable 2/taxable 3/taxable 4/non-taxable) for gratuity.

Example

When a percent rate of the gratuity is programmed as 10%:
Key operation

Print

500 5

a

Exemption
Your register allows you to exempt a customer from the gratuity by pressing the
operation.

Example

GRT
EXEMPT

key prior to a payment

When a percent rate of the gratuity is programmed as 10%:
Key operation

Print

1250 5
1000 6
GRT
EXEMPT

a

61

8 Payment treatment
Tip-in entries
Your register allows the entry of tips that your guests give to cashiers/servers in cash or by credit card.
A tip entry must be done before a payment entry.
You must use the corresponding media key e.g. CH1 thru CH9 for the charge tip and CASH 1 or CASH 5 for the
cash tip.
Two different tip-in entry systems are available: the tip amount entry system and the tip percent rate entry
system. It depends on how your register has been programmed which of these systems is used.

Procedure
Tip amount entry system:

CA
TIP

Tip amount

CH
TIP

When you use a programmed percent rate
Tip percent rate entry system:

Example

Tip percent rate
(0.01 - 99.99)

CH
TIP

Receiving $3.00 by cash as a tip
Key operation

300

Print
CA
TIP

a

62

CA
TIP

Tip editing
This function is used for entering tip amounts after finalizing a guest check with a charge tender. This is only
available when the guest check transaction is finalized through CAT authorization and the tip is to be paid in
charge tender. The bill number which is issued when the S or f key is pressed in guest check entry must be
ED
used in order to identify the guest to edit or add tip amount. For the operation, press the TIP key. When the
ED
display prompt appears, enter the bill number and press the u key, then enter tip amount and press the TIP
key again.
To use the tip editing function, please consult your authorized SHARP dealer.

Tip paid entries
This operation is used when tips that guests have paid by using credit card are paid to respective
cashiers/servers in cash. To perform a tip paid entry, enter the cashier/server code, then press the † key.
You can prohibit the tip paid operation in the REG mode by the PGM2 programming.

Note

When the tip amount remains unchanged in Individual Server Resetting, the tip paid function is
automatically executed and tip receipt is issued to the report printer prior to report printing.

63

Currency conversion
Your register allows payment entries of foreign currency. Pressing the ç thru $ key creates a subtotal in
foreign currency. Cash payment is the only media that can be handled after currency conversion.

Procedure
For an additional payment in foreign currency
After an entry
is completed
or
After the amount
tendered is found
smaller than the
sales amount in
a sales entry.

For direct finalization
Preset rate

*Rate

ç
"
#
$
Reentry

Amount
tendered
(max. 8 digits)

c

a
Å

thru

É

Next registration
or
payment in
domestic currency

*Rate: 0.000000 to 999.999999

Note

When the amount tendered is short, the deficit is shown in domestic currency.

Example

To convert the amount owed ($69.50) into the designated foreign currency
Preset rate (1.325) - CONV 1
Key operation

Print

2300 6
4650 7

Currency
conversion
Amount
tendered in
foreign currency

ç
10000 a

Domestic
currency
Conversion rate
Foreign currency
Domestic
currency

Manual rate - CONV 4 (The $ key can be used only for the manual entry.)
Key operation

2300 6
4650 7
1 . 275 $
10000 a

64

Print

Conversion
rate

Received on account entries
Procedure

Amount
(max. 8 digits)

Example

a Å É
k CHK2 CHK5

r
®

,

thru

,

thru

or

CH1

thru

CH9

f

A customer whose reference number is 12345 tenders $48.00 by check for received on
account.
Key operation

Print

12345 =
4800 r
#/
TM

k

Paid out entries
Procedure

Amount
(max. 8 digits)

Example

a Å É
k CHK2 CHK5

p
π

,

thru

,

thru

or

CH1

thru

CH9

f

You pay $30.00 by check to a vendor whose code number is 6789.
Key operation

Print

6789 =
3000 p
#/
TM

k

No sale (exchange)
Simply press the n key without any entry. The drawer will open and the printer will print “NO SALE” on both
the journal and the receipt. If your machine is preset to print a non-add code number before pressing the n
key, a no sale entry is achieved with a non-add code number printed.

65

Cashing a check
Enter the check amount, then press a check key (k,

CHK1

thru

CHK5

).

Procedure
Non-add code
number

Example

#/
TM

Check
amount

k

, CHK2 thru CHK5

Cashing a check of a $30.00 amount
Key operation

Print

6789 =
3000 k
#/
TM

Bottle return
This function is used to handle the payment (paid out) for returned empty bottles or cans.

Example

You pay for ten 15¢ returned empty bottles. (This example presupposes that dept. 10 has
been programmed as bottle return department.)
Key operation

Print

10 @
15 10

a

9 Automatic sequencing key entries
You can achieve many different key sequences automatically with a single key depression by using an
automatic sequencing key (~ thru 10 ).

Example

Performing the transaction “Selling a $5.00 item (dept. 7) for cash” programmed for the ¡
(¡ = 500 7 a)
Key operation

¡

66

Print

10 WASTE mode
This mode is used to throw away an article which has already been prepared and is no longer serviceable.

Procedure
WASTE

[Item entries ]

WASTE

WASTE mode

Example

Wasting 10 PLU 35 items
Key operation

Print
WASTE

10 @ 35

PLU/
UPC

WASTE

Note

• PLU/UPC entries are only allowed in the WASTE mode, and direct and indirect void operations
are also allowed in this mode.
• When a WASTE mode transaction is finalized, the drawer does not open.
• The consecutive number is incremented every WASTE mode transaction.
• When the WASTE mode is activated by pressing the WASTE key, the mode caption “WAST” is
displayed.

67

CORRECTION
1 Correction of the last entry (direct void)
If you make an incorrect entry relating to a department, PLU/subdepartment, UPC, percentage (% through
•), deduction (- through ≠) or refund, you can correct this entry by pressing the v key immediately after
the incorrect entry.

Example

Key operation

Print

1250 6

v
PLU/
2P
UPC

v
PLU/
5012345678900 P
UPC

v
600 8

§
v
328 9
28 - 9
v
250 Ï 8
v
a

2 Correction of the next-to-last or earlier entries (indirect void)
With the v key, you can void any incorrect department, PLU/subdepartment, UPC or item refund entry made
during a transaction if you find it before finalizing the transaction (e.g. pressing the a key). This function is
applicable to department, PLU/subdepartment, UPC and item refund entries only.
For the operation, press the v key just before you press a department key, à key, direct PLU key,
just before you scan a UPC code. For the refund indirect void, press the v key after you press the
Ï key.

Example

Key operation

Print

1310 6
1755 7
PLU/
10 P
UPC

ô
PLU/
58 P
UPC
825 7
PLU/
5012345678900 P
UPC
1310 v 6

vô
PLU/
58 v P
UPC
PLU/
5012345678900 v P
UPC

a
68

PLU/
UPC

key or

3 Subtotal void
You can void an entire transaction. Once the subtotal void is executed, the transaction is aborted and the
register issues a receipt.

Example
Key operation

Print

1310 1
1755 6
PLU/
10 P
UPC
PLU/
35 P
UPC
Subtotal void

ı
v
ı

Correction of incorrect entries not handled by the direct or indirect void

4 function

Any errors found after the entry of a transaction has been completed or during an amount tendered entry, cannot
be voided. These errors must be handled by the manager.
The following steps should be observed:

1.
2.
3.

If you are in the middle of making an amount tendered entry, you must first finalize the transaction before
making corrections.
Try to make correct entries from the beginning.
Hand the incorrect receipt to your manager for its cancellation.

69

CORRECTION AFTER FINALIZING A
TRANSACTION
(AFTER GENERATING A RECEIPT)
When you need to void incorrect entries that are found after finalizing a transaction or cannot be corrected by
direct or indirect void, follow this procedure in the MGR mode.

1.
2.
3.

Turn the mode switch to the MGR position.
Press the v key to put your register in the VOID mode.
Repeat the entries that are recorded on an incorrect receipt. (All data for the incorrect receipt are removed
from register memory; the voided amounts are added to the void register totalizer.)
Incorrect receipt

Note

70

Cancellation receipt

Your machine leaves the VOID mode whenever a transaction is canceled (i.e. finalized in the VOID
mode.) To void additional transactions repeat steps 2. and 3. above.

OVERRIDE ENTRIES
Programmed limits (such as maximum amounts) for functions can be overridden by making the entry in the
MGR mode.

Procedure

1.
2.

Turn the mode switch to the MGR position.
Make the override entry.

Example

Selling a $15.00 item (dept. 2) for cash and subtracting the coupon amount $2.50 from the
sale amount (This example presumes that the register has been programmed not to allow
coupon entries over $2.00.)
Key operation

Print

1500 2
REG-mode250 –2 ...Error
entries
c
Turn the mode switch
to the MGR position.
250 –
Return the mode switch
to the REG position.

a

71

OVERLAPPED CASHIER/SERVER
ENTRY
This function allows you to switch from one cashier/server to another interrupting the first cashier/server’s entry.
The second cashier/server can make a sales entry, then the first cashier/server may continue.

Example
Cashier 1: Entry started
Cashier 2: Cashier/server change (1 to 2), interruption initiated
Cashier 2: Transaction finished (2)
Cashier 1: Cashier/server change (2 to 1), entry restart

Note

• The overlapped cashier/server entry is not available while the tendering sale.
• If any cashier/server is still making an entry (or has not finalized the transaction yet), the machine
does not run in any mode other than REG and MGR and X/Z reports can not be performed. The
error message “SERVER ERR.” and the corresponding cashier/server code(s) are displayed at
this time.
Key operation

Comments

1. Cashier/server 1 is assigned.

The entry by cashier/server 1 is started.

(1‹)
100 1
360 3

3
2. Cashier/server 2 is assigned.

2‹
3@
150 2

a

The entry by cashier/server 2 is started.
(The entry by cashier/server 1 is interrupted.)

The transaction by cashier/server 2 is finalized.

3. Cashier/server 1 is assigned.

1‹
100 1
360 3

a

72

The entry by cashier/server 1 is restarted.

The transaction by cashier/server 1 is finalized.

SPECIAL PRINTING FUNCTIONS
1 Copy receipt printing
If your customer wants a receipt after you have finalized a transaction with the receipt ON-OFF function in the
“OFF” status (no receipting), press the q key. This will make a copy receipt. Your register can also print a
copy receipt when the receipt ON-OFF function is in the “ON” status.

Note

Pressing the q key in the OP X/Z mode before registration toggles the status “ON” and “OFF”.

Example

Printing a copy receipt after making the entries shown below with the receipt ON-OFF function
in the “OFF” status
Key operation

850 2
3@
150 1

a

For receipting→

Print

Print on the
journal

q
Print on the
receipt

When the receipt ON-OFF function is in the “ON” status and you press
the q key to make a second copy

When the receipt ON-OFF function is in the ON status,
the COPY symbol will be printed on the receipt.

73

2 Validation printing function (Slip printer)
Your register can perform validation printing when it is connected with the slip printer. For the details about the
slip printer, contact your authorized SHARP dealer.
1. Set a validation slip to the slip printer.
2. Press the ∏ key. The validation printing will start.

Note

When you make an entry for which compulsory validation printing can be overridden by performing
the following operation. If you need this function, Contact your authorized SHARP dealer.

1.
2.

Move the mode key to the MGR position.

.

∏

3 Bill printing
This function is used for issuing bills to customers/guests. Your register can print bills on a slip printer or
receipts on the register depending on the programming. You can issue bills when GLU/PBLU/Manual PB/CB
entries are done only, for every entry or when a media key is pressed. For this selection, please consult your
authorized SHARP dealer.
When bill printing is compulsory, the register will print a bill automatically in case it is to be printed on receipts
and when a slip is inserted in case it is to be on a slip printer.
When bill printing is non-compulsory, use the following procedure to print a bill.
Bill on receipts
Bill on the slip (auto feed)

Ω

XX
No. of lines of
slip feed

Note

This function is available immediately after the finalization of transaction (including after pressing
the S or the f key).

4 Printing of the employee’s arrival and departure times (Slip printer)
Your register can print the employee’s arrival and departure time when it is connected with the slip printer.
For the details for connecting a slip printer, please contact your authorized SHARP dealer.
For printing of the arrival and departure times, you must be in the OP X/Z mode.
Printing of arrival time

1

∏

Printing of departure time

2

74

∏

5 Printing of header and footer graphic logos
As an optional setting, your register can print a graphic logo on the top of each receipt (header graphic logo). If
preset to do so, a graphic logo can be printed on the bottom of each receipt (footer graphic logo) with the job
code #2616. You can also print the graphic logos with the combination of 3-line header logo message or 3-line
footer logo message. Printing only logo messages without the graphic logo is possible. Please consult your
dealer when you want to change the setting.
• Sample receipt with a header graphic logo and a footer graphic logo

Header graphic logo

Footer graphic logo

6 Remote printer send function
This function enables a partial order to be sent to the kitchen for preparation while the remaining order is still
being placed.

Example
Item entry

RP
SEND

Data transfer to the remote printer

Remaining items will be sent to the remote printer when the transaction is finalized.
When this function is used, the subtotal void operation is not allowed.

75

TIME DISPLAY AND AUTOMATIC
UPDATING OF THE DATE
1 Time display
When you need the time displayed, turn the mode switch to the OP X/Z position after the preceding transaction
or operation is finalized.
#/
You can also display the time by pressing the TM key in the REG or MGR mode.
The time display disappears as soon as you press the c key in the REG or MGR mode or begin the
subsequent entry.
Sample display of 10:25 AM

Date
Time

2 Automatic updating of the date
Once the internal clock unit is started at the correct time, it continues to run as long as the built-in battery is
charged, and updates the date (month, day, year) automatically.

76

FOR THE MANAGER

PRIOR TO PROGRAMMING
1 Programming keyboard layout
When you are in the PGM1 or PGM2 mode, the keyboard layout will be set to one of the programming layouts
as shown below.

For ER-A520

(NUM)

RECEIPT JOURNAL

( )
( )
( )
( )

@

( )

FOR

( )
PO

7

8

4

(%)
( )

5
2

1
0

(SHIFT) (SHIFT-2) (SPACE)

æ BACK
Æ SPACE

cl

(DC)

CL

”

9

’

6

:

3

+

A

”

#

G

B

<

>

?

Z

W

Ç

N

I

D

Y

V

R

=

)

!

.

M

H
-

(

Q

L
,

;

X

U

/

SBTL

S

Pt

£

E

J

O

T

}

[

]

)

&

%

P

K
@

C

00

$

F

(

CA/AT/NS

For ER-A530

?

<

>

6

( 13

)

=27

➞

▲

’

”

!

@

#

$

%

^
L2

DEPT
&
#

1

œ
2

3

4

5

6

7
CR2

85

912

019

-26

Q

AUTO
W

E

R

T

Y

CR1
U

I

4

O11

P18

–25

A

S

D

F

G

H

J

K3

L10

; 17

:

7

8

9

Z”

X

C

V

B

N

M2

,

.

–

4

5

6

1

2

3

0

00

+33
@

(SHIFT) (DC) (SPACE) (SPACE) (SPACE) (SPACE) (SPACE)

Note

Î:
Ó:
é:

BACK
(SPACE
)

➞

?

{

▲

Ñ

➞

➞

”

RECEIPT JOURNAL

CL

FOR

SBTL CA/AT

• The programming keyboard sheet is transparent, allowing placement over the standard keyboard
sheet.
• The shaded area contains the character keys which are used for programming characters.

Used to enter the double-size character.
Used to change a lower-case letter/upper-case letter.
Used to select a symbol. (ER-A520 only)

cl

æ
Æ

To enter the letter “ cl cl ”, press

é

cl

æ
Æ

é

To enter the upper-case letter “Æ Æ”, press
To enter the lower-case letter “æ æ”, press


/

: Used to back up the cursor for deleting.

(NUM)

: Used to enter a numeric character. (ER-A520 only)

cl

æ
Æ

Ó

æ
Æ

cl

cl
cl

æ
Æ

æ
Æ
cl

æ
Æ

Ó

: Used to enter a space.

77

2 How to program alphanumeric characters
You can program alphanumeric characters for departments, PLUs, UPCs, functions, etc. while in the character
entry mode.
There are two ways for programming characters: using character keys on the keyboard and entering character
codes with the numeric keys on the keyboard.

Using character keys on the keyboard (keys on the shaded area)
Enter a character according to the position in the programming keyboard layout.

Entering alphanumeric characters
To enter a character, simply press a corresponding character key.

ˆ

In case of ER-A520, “( )”, “( )”, “( )”, “ ( )”, “( )”, “( )”, “( ° )”, and “( )” keys can be used in combination
ˆ
¨
`
´
´´
˜
with a character key. If the combination is unavailable, only a character key is entered.
[Ex.] “Å” : ➞ (°) ➞ A
To enter a numeric character:
(ER-A520) Press (NUM) key and enter a number by ten keys (0 – 9).
(NUM) ➞ 135 ➞ (NUM)
[Ex.] Entering the character “135” :
(ER-A530) Simply press a corresponding numeric key in the shaded area.
To enter a space, press the / key.

Entering double-size characters

Î

: This key toggles the double-size character mode and normal-size character mode. The default is the
normal-size character mode. The double-size character is displayed with the letter “=” (ex. =S).
[Ex.] To program the name “SHARP” in double size : Î ➞ SHARP ➞ Î

Entering lower-case letters

Ó

: You can enter a lower-case letter by using this key. Press Ó key just before you enter the lower-case
letter. This key also allows you to enter the characters/symbols shown at the upper right of keys.
[Ex.] To program the name “Sharp” : ➞ S ➞ Ó ➞ harp ➞ Ó

Entering symbols shown at the upper left of keys (ER-A520 only)

é:

You can enter symbols by using this key. Press é key just before you enter the symbol.
[Ex.] To program the symbol “ cl cl ” : ➞ é ➞ cl ➞ é ➞ cl

Editing text
You can edit the text you have entered by deleting characters.
: Backs up the cursor for deleting the character or figure at the left of the cursor.



Entering character codes
Numerals, letters and symbols are programmable by entering the º key and character codes. See the
“Alphanumeric character code table” on the next page. In this way, you can program characters other than the
characters shown in the programming keyboard layout.
XXX ➞ º

Note

XXX: Character code (3 digits)

• Double-size characters can be made by entering the character code 253.
[Ex.] To program the name “SHARP” in double size
253

º

(DC)

78

083
S

º

072
H

º

065
A

º

082

º

R

080

º

P

Alphanumeric character code table
Code Character
091
Ä
092
Ö
093
Ü
094
^
095
_
096
’
097
a
098
b
099
c
100
d
101
e
102
f
103
g
104
h
105
i
106
j
107
k
108
l
109
m
110
n
111
o
112
p
113
q
114
r
115
s
116
t
117
u
118
v
119
w
120
x
121
y
122
z
123
{
124
|
125
}
126
ß
127
¢
128
!!
129
1
130
2
131
3
132
4
1/2
133
F/T
134
←
135

Code Character
136
→
137
138
139
140
141
F
142
T
↓
143
ç
144
°
145
¿
146
Ù
147
à
148
Æ
149
ø
150
Å
151
152
¤
é
153
è
154
Pt
155
i
156
Ñ
157
ò
158
£
159
¥
160
161
°
162
163
164
.
165
Á
177
Í
178
A
180
a
181
E
182
e
183
I
184
i
185
186
U
u
187
N
188
.
n.
189
190
C
191
S
C
192
.

▲

Code Character
046
.
047
/
048
0
049
1
050
2
051
3
052
4
053
5
054
6
055
7
056
8
057
9
058
:
059
;
060
<
061
=
062
>
063
?
064
@
065
A
066
B
067
C
068
D
069
E
070
F
071
G
072
H
073
I
074
J
075
K
076
L
077
M
078
N
079
O
080
P
081
Q
082
R
083
S
084
T
085
U
086
V
087
W
088
X
089
Y
090
Z

▲

Code Character
001
á
002
â
003
ê
004
î
005
ì
006
í
007
ô
008
ó
009
û
010
ú
011
œ
012
u
´´
013
ú
014
o
´´
015
ó
016

017

018

019
¨
020

021

022

023

024

025
	
026


027

´´
028
U
029
Ú
´´
030
O
031
Ó
032
(space)
033
!
034
”
035
#
036
$
037
%
038
&
039
’
040
(
041
)
042
043
+
044
,
045
-

Code Character
.
193
.I
194
G
195
S.
196
G
..
197
g
198
K.
199
k.
L
200
l
201
202
Z
203
D
204
d
205
C
206
c
207
P
208
209
e
210
s
211
c
212
z
213
y
214
.
u
215
n
216
217
218
r
219
224
§
225
Ø
226
227
↑
228
]
229
[
230
231
”
ä
232
ö
233
ü
234
æ
235
å
236
É
237
ñ
238
*(DC)
253

✱
✱

(DC) : Double-size character code
: The shaded character cannot be displayed (will be displayed as space).

Note

The character “ !! ” (code: 128) is displayed as “ ! ”.

79

PROGRAMMING
This chapter illustrates how to program your cash register.

Basic instructions
All the programming items can be programmed by the Job-Code-Based Programming described later.
Also your machine allows you to program some items using the Direct Programming, which does not require
you to enter the job code. However, object keys (shown below) must be allocated on the keyboard. For the keys
not allocated on the keyboard, you cannot use the direct programming.
Job-Code-Based Programming
Simplified procedure :

XXX
(Job code)

@

.

Data entry

Ç

Direct Programming
Sample procedure :

Data entry

–

Ç

(Object key)

Preparations for programming
1.
2.
3.
4.

Plug your machine into a standard grounded AC outlet.
Turn the mode switch to the PGM1 or PGM2 position.
To set the mode switch to the PGM1 position, use the manager or submanager key; and to set it to the
PGM2 position, use the manager key.
Check to see whether both journal and receipt rolls are present in the machine. If they are missing, install
journal and receipt paper rolls correctly referring to the procedure in “4. Installing and removing the paper
roll” under “OPERATOR MAINTENANCE”.
Program the necessary items into your machine.

Direct Programming
1 Setting the date and time
Date

PGM 1

PGM 2

Enter the month (one or two digits), day (two digits), and year (four digits : 2000 – 2099) in this sequence.

Procedure
XXXXXXXX
Date (seven or eight digits)

#/
TM

Example
Key operation

Print

08262004 =
#/
TM

Date

80

Time

PGM 1

PGM 2

Set the time using the military time (24-hour) system. For example, when the time is set to 2:30 AM, enter 230;
and when it is set to 2:30 PM, enter 1430. The time will be printed and displayed using a real-time system. Once
you set the time, the internal clock unit will continue to run as long as the built-in battery is alive and update the
date (day, month, year) properly.

Procedure
#/
TM

XXXX
Time (max. four digits)

Example
Key operation

Print

1430 =
#/
TM

Time

2 Programming for departments
Your machine is equipped with 20 (ER-A520)/10 (ER-A530) standard departments and a maximum of 99
departments. Your machine allows you to perform the following programming for each department.

Unit price

PGM 1

PGM 2

Procedure
To program any dept.
To program zero

1

Unit price (max. 6 digits)
Dept. code (1 — 99)

à

99
·

Unit price (max. 6 digits)

Ç
ı

To program zero
To program the next sequential dept.

Example
Key operation

Print

1000 1

Ç
Unit price

81

Functional selection

PGM 2

Procedure
To program any dept.
To set all zeros

@

*1 ABCDEFGHIJKLMNOP
Dept. code (1 — 99)

à

1

99
·

*1 ABCDEFGHIJKLMNOP

Ç
@

To set all zeros
To program the next sequential dept.

*1

Item:
A
Group number
B
Commission group number
C
Sign (plus/minus)
D
E
F
G
H
I
J
K

L

M

N

O
P

82

Selection:

Entry:
0 thru 9 (0: Non group)
0 thru 9 (0: Non commission)
Plus
0
Minus
1
Food stamp status
Ineligible
0
Eligible
1
Tax 4 status
Non-taxable
0
Taxable
1
Tax 3 status
Non-taxable
0
Taxable
1
Tax 2 status
Non-taxable
0
Taxable
1
Tax 1 status
Non-taxable
0
Taxable
1
Item validation printing
Non-compulsory
0
Compulsory
1
Tare table number
0 thru 9 (0: not used)
Scale entry
Inhibit
0
Enable
1
Compulsory
2
Registration type
Normal
0
SICS (Single Item Cash Sale)
1
SIF (Single Item Finalization)
2
Department type
Normal department
0
Hash department
1
Bottle return department
2
Gas department
3
Type of unit price entry
Inhibit department key
0
Open only
1
Preset only
2
Open and preset
3
Significant digit for HALO
1 thru 9
Number of zeros to follow the significant digit for HALO
0 thru 7

Note

Group number
You can assign a department to a maximum of nine groups. This programming enables you to take
group sales reports.
Commission group number
A commission group number (0–9, 0: non commission) can be assigned to each department.
Sign (plus/minus)
• Assign a plus sign to departments for normal sales transactions.
• Assign a minus sign to departments for minus transactions.
Food stamp status
• Assign a food stamp status (food stamp eligible or food stamp ineligible) to each department.
Tax status (taxable 1 thru 4/non-taxable)
• When an entry of a taxable department is made in a transaction, tax is automatically computed
according to the associated tax table or rate.
• Tax 4 is prohibited if you use the food stamp function.
Item validation printing
If item entries must be validated, program corresponding departments for compulsory validation
printing.
Tare table number
Tare table number associated with scale entry (1 thru 9).
Scale entry
Program a department for scale entry when your store requires items to be sold by weight and are
placed on a scale connected to the register.
Registration type
• If an entry of a department programmed for SICS is made first, the sale will be finalized as soon
as the department key is pressed. If the entry is made after entering a department not
programmed for SICS, the sale will not be finalized until the Ç key is pressed.
• Whenever a sale is made to a department programmed for SIF, the sale is finalized as soon as
the department key is pressed.
Department type
You may program each department as one of the following three types.
• Normal department
• Hash department
A hash department is used to enter the amount of a special “sale”, such as a gift certificate sale or
for the receipt of payment for utility bills, theatre tickets, etc., i.e. “non-sales” registrations. Any
amounts entered in this department are not added to the grand total except tax amounts.
• Bottle Return (BR)
• Gas department
The gas department enables you calculate the quantity of gas sold in gallon by using a preset unit
price when the sale amount of gas is entered. (quantity of gas = sales amount entered / preset
unit price)
Also gas discount can be automatically applied to the sales. (discount amount = total amount of
gas x reduced unit price for each media; cash/check/charge)
Type of unit price entry
You may select one of the following four types of unit price entry for each department.
• Open and preset
• Preset only
• Open only
• Inhibit department key
HALO (High Amount Lockout)
You can set an upper limit amount (HALO) for each department. The limit is affective for the REG
mode operations and can be overridden in the MGR mode.
• “OP” is the same as O × 10P
For example, presetting 14 ($100.00) here means that amount entries of up to $100.00 are
allowed in the REG mode. When you preset 17, the upper limit amount is 99999.99.

83

Example
Key operation

Print

1000000100000317 @ 1

Ç

Taxable1
Commission
group no.
HALO
Group no.

IJKLMN

Food stampstatus F:Eligible
(None):Ineligible

3 PLU/UPC programming
Your machine is equipped with 2000 standard PLU/UPC codes. Your machine allows you to perform the
following programming for each PLU/UPC.

Note

• Please note that the price lookup/subdepartment/UPC key (P for ER-A520) is shown as PLU/
UPC .
• To review the UPC codes available to this register, please refer to the chapter 13 in “Universal
Product Code(UPC) or European Article Number(EAN)”.
• Ä in Procedures indicates that you scan a barcode.

Unit price

PGM 1

PGM 2

Procedure
To program any PLU/UPC

l
Level no.
(1 to 5)

5

Ä

To keep current setting

Direct PLU key

Unit price 1
(max. 6 digits)

ı

Ç

ä

PLU code (max. 5 digits)

PLU/
UPC

* To program unit price 2 thru 6 (only when price shift function is allowed.)
To program for the following PLU/UPC

UPC code (6 to 13 digits)

* In case that price shift function is allowed, the register prompts to enter a unit price for the following level by
displaying “P2” thru “P6” on the display, and when a unit price of level 6 is entered, the register goes to the
status for programming the following PLU/UPC. When you press the Ç on the way of programming multiple
prices for a PLU/UPC code, prices for the remained levels are kept unchanged.
In case that single price entry is allowed for a PLU/UPC code, the register goes to the status for programming
the following PLU/UPC.

Example
Key operation

Print

PLU/
UPC 1000 ı
1P

Ç
Unit price

84

(In case of single price entry)

Functional selection

PGM 2

Procedure
To program any PLU/UPC

Ä

l
Level no.
(1 to 5)

Direct PLU key

5

ä

To program zero
*1 ABCDEFGHIJ

Ç

@

To program for the following PLU/UPC
PLU/
UPC

PLU code (max. 5 digits)
UPC code (6 to 13 digits)

*1 Item:
A
Commission group number
B
Sign (plus/minus)
C

Food stamp status

D

Tax 4 status

E

Tax 3 status

F

Tax 2 status

G

Tax 1 status

H
I

Tare table number
Scale entry

J

Type of unit price entry

Note

Selection:
Plus
Minus
Ineligible
Eligible
Non-taxable
Taxable
Non-taxable
Taxable
Non-taxable
Taxable
Non-taxable
Taxable
Inhibit
Enable
Compulsory
Prohibit mode
Open price only
Preset price only
Open price and preset price
Delete mode

Entry:
0 thru 9 (0: Non commission)
0
1
0
1
0
1
0
1
0
1
0
1
0 thru 9 (0: Not used)
0
1
2
0
1
2
3
4

Commission group number
A commission group number (0–9, 0: non commission) can be assigned to each department.
Sign (plus/minus)
The function of every PLU/UPC varies according to the combination of its sign and the sign of its
associated department as follows:
Sign
Department
+
–
+
–

PLU/UPC
+
–
–
+

Function of PLU/UPC
Serves as a normal plus PLU/UPC
Serves as a normal minus PLU/UPC
Accepts store coupon entries, but not split-pricing entries
Not valid; not accepted

Food stamp status
• Assign a food stamp status (food stamp eligible or food stamp ineligible) to each PLU/UPC.

85

Tax status (taxable 1 thru 4/non-taxable)
• When an entry of a taxable PLU/UPC is made in a transaction, tax is automatically computed
according to the associated tax table or rate.
• Tax 4 is prohibited if you use the food stamp function.
Tare table number
Tare table number associated with scale entry (1 thru 9).
Scale entry
Program a PLU/UPC for scale entry when your store requires items to be sold by weight and are
placed on a scale connected to the register.
Type of unit price entry
You may select one of the following four types of unit price entry for each PLU/UPC.
• Open price and preset price (for only PLU)
• Preset price only
• Open price only (for only PLU)
• Prohibit mode: Prohibits the entry of any assigned PLU/UPC code.
• Delete mode: Deletes data programmed for each PLU/UPC.

Example
Key operation

Print

PLU/
UPC 0000001003 @
1P

Ç
Taxable1

Commission
group no.

(HIJ)

Associated department

PGM 1

PGM 2

Procedure
To program any PLU/UPC
To delete the entered PLU/UPC

v

Ä

l
Level no.
(1 to 5)

Direct PLU key

5

Associated department code
(1 – 99)

ä

1

PLU code (max. 5 digits)

PLU/
UPC

à

Ç

99
·

To program for the following PLU/UPC

UPC code (6 to 13 digits)

Example
Key operation

Print

PLU/
1P
UPC 1

Ç

86

Associated
dept. code

4 Programming for discount keys (-)
Discount amount

PGM 1

PGM 2

Procedure
To program zero

- ±

Discount amount (max. 6 digits)

Ç

Example
Key operation

Print

1000 -

Ç
Discount
amount

Functional programming

PGM 2

Procedure
To program zero
*ABCDEFGHI

@

- ±

Ç

To program any coupon function

* Item:

Selection:

A

Food stamp status

Ineligible
Eligible
Non-taxable
Taxable
Non-taxable
Taxable
Non-taxable
Taxable
Non-taxable
Taxable
Plus
Minus

B

Tax 4 status

C

Tax 3 status

D

Tax 2 status

E

Tax 1 status

F

Sign (+/-)

G

Vendor/store coupon selection

H
I

Significant digit for HALO
Number of zeros to follow the significant digit for HALO

Vendor coupon (subtotal _)
Store coupon (item _)

Entry:
0
1
0
1
0
1
0
1
0
1
0
1
0
1
1 thru 9
0 thru 7

87

Note

Tax status (taxable 1 thru 4/non-taxable)
Tax 4 is prohibited if you use the food stamp function.
HALO (High amount lockout)
“HI” is the same as H x 10 I.
For example, presetting 14 ($100.00) here means that amount entries of up to $100.00 are allowed
in the REG mode. When you preset 17, however, the upper limit amount is 99999.99.
When you preset 00, the open amount entry is prohibited.

Example
Key operation

Print

000011013 @ -

Ç
HALO

Taxable 1
Food stamp status F:Eligible
(None):Ineligible
Subtotal _

5 Programming for percent keys (%)
Percent rate

PGM 1

PGM 2

Procedure
To program zero
*Rate

) (¡) ∞

Ç

* Rate: Percent rate: 0.00 – 100.00

Note

You must use a decimal point key when setting percentage rates that are fractional.

Example
Key operation

Print

10 . 25 %

Ç
Percent
rate

88

Functional programming

PGM 2

Procedure
To program zero

@

*ABCDEFGHIJ

) (¡) ∞

* Item:
A
Type of amount entry

B

Food stamp status

C

Tax 4 status

D

Tax 3 status

E

Tax 2 status

F

Tax 1 status

G

Sign (+/-)

H

item%/subtotal% selection

I
J

Always enter 0.
Always enter 0.

Note

Ç

Selection:
Inhibit percent key
Open only
Preset only
Open and preset
Ineligible
Eligible
Non-taxable
Taxable
Non-taxable
Taxable
Non-taxable
Taxable
Non-taxable
Taxable
Plus
Minus

Entry:
0
1
2
3
0
1
0
1
0
1
0
1
0
1
0
1

Subtotal %
Item %

0
1
0
0

Tax status (taxable 1 thru 4/non-taxable)
Tax 4 is prohibited if you use the food stamp function.

Example
Key operation

Print

3000011000 @ %

Ç
Taxable 1
Subtotal %

89

6 Programming for conversion keys (ç)
Currency conversion rate

PGM 1

PGM 2

Procedure
To program zero
*Conversion rate

ç #

Ç

* Conversion rate: 0.0000 – 9999.9999

Note

You must use a decimal point key when setting conversion rates that are fractional.

Example
Key operation

Print

0 . 8063 ç

Ç

7 Programming for the r, p, and † keys
High amount lockout (HALO)

PGM 2

The HALO limit effects REG mode operations but can be overridden in the MGR mode.
The HALO limit is represented by two figures as follows:

Procedure

AB

r A
p π
†
or

To program zero

@

or

Ç

(Only for manual entry)

“AB” is the same as A × 10B.
A: Significant digit (0 through 9)
B: Number of zeros to follow significant digit: (for RA or PO: 0 thru 9), (for manual tax: 0 thru 7)

Example
Key operation

Print

13 @ r

Ç
90

CA , ', and k keys
8 Programming for the Ç, Å

High amount lockout (HALO) and functional selection

PGM 2

Procedure

h CH9
k CHK5
Å É
s

To program zero
*ABCDEFGHIJKL

@
(For

Ç

* Item:
A

key)

Selection:
GLU/PBLU/Manual PB/CB entry

Enable
Inhibit
Compulsory
Enable
Disable
No
Yes
Non-compulsory
Compulsory
No
Yes
Non-compulsory
Compulsory
Enable
Disable
Non-compulsory
Compulsory
Yes
No
Optional amount tendered for cash or check
Inhibit amount tendered for charge
Compulsory amount tendered

B

Short amount tender entry

C

Retention of closed GLU/PBLU file

D

Bill (slip) printing

E

Footer printing on receipt

F

Non-add code entry

G

Change enable (over tender enable)

H

Validation printing

I

Drawer opening

J

Amount tendered operation

K
L

Significant digit for HALO
Number of zeros to follow the significant digit for HALO

Note

Ç

Entry:
0
1
2
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
0
1
0 thru 9
0 thru 8

HALO (High amount lockout)
“KL” is the same as K × 10 L.
For example, presetting 13 ($10.00) here means that amount entries of up to $10.00 are allowed in
the REG mode. When you preset 18, however, the upper limit amount is 999999.99.

91

Example
Key operation

Print

000000000015 @ )

Ç
HALO

A thru J

92

9 Programming for the automatic tax calculation function
Your machine has an automatic tax calculation feature which allows you to program four tax tables to avoid
calculating incorrect tax amounts.
Automatic tax calculations require you to program, in addition to the tax table, the tax status of each pertinent
department, PLU/UPC, and function key.

The tax table (applicable to the add-on tax)

PGM 2

Sample tax table
New Jersey tax table: 6%
Range of sales amount
Taxes
.00
.01

Minimum breakpoint
.01

T

.11

Q

Maximum breakpoint

A: Difference between the
minimum breakpoint and
the next one (¢)

to

.10

–

to

.22

10 (0.11 - 0.01)

.02

.23

to

.38

12 (0.23 - 0.11)

.03

.39

to

.56

16 (0.39 - 0.23)

.04

.57

to

.72

18 (0.57 - 0.39)

.05

.73

to

.88

16 (0.73 - 0.57)

to

1.10

16 (0.89 - 0.73)

to

1.22

22 (1.11 - 0.89)

.06

.89

.07

1.11

.08

1.23

to

1.38

12 (1.23 - 1.11)

.09

1.39

to

1.56

16 (1.39 - 1.23)

.10

1.57

to

1.72

18 (1.57 - 1.39)

.11

1.73

to

1.88

16 (1.73 - 1.57)

.12

1.89

to

2.10

16 (1.89 - 1.73)

.13

2.11

to

2.22

22 (2.11 - 1.89)

M1

M2

B: Non-cyclic

C: Cyclic-1

D: Cyclic-2

To program a tax table, first make a table like the right table shown above.
From the tax table, calculate the differences between a minimum break point and the next one (A). Then, from
the differences, find irregular cycles (B) and regular cycles (C and D). These cycles will show you the following
items necessary to program the tax table:
T:
Q:
M1:
M2:
M:

The tax amount collected on the minimum taxable amount (Q)
The minimum taxable amount
The maximum value of the minimum breakpoint on a regular cycle (C).
We call this point “MAX point.”
The maximum value of the minimum breakpoint on a regular cycle (D).
We call this point “MAX point.”
Range of the minimum breakpoint on a regular cycle: difference between Q and M1 or between M1 and
M2

93

Procedure
One- or two-*1
digit number

†
T

max. three
digits

@

@

@

*2
Rate
max. six digits
(0.0001 - 99.9999%)

@

Q
max. five
digits

M
max. four
digits

Minimum breakpoint
max. five digits

@
@

Ç

Repeat until the MAX point is entered.

To delete a tax table, use the following sequence:
One- or two-*1
digit number

†

@

@

*2
Rate
max. six digits
(0.0001 - 99.9999%)

M
max. four
digits

@

t

*1 First figure:

The first figure to be entered depends upon whether the difference between a minimum
breakpoint to be entered and the preceding minimum breakpoint is not less than $1.00 or
more than 99¢. When the difference is not less than $1.00, enter “1,” and when it is not more
than 99¢, enter “0” or nothing.
Second figure: The second figure depends upon whether your tax table is to be programmed as tax table 1,
2, 3 or 4. When your tax table is to be programmed as tax table 1, enter “1”; when it is to be
programmed as tax table 2, enter “2”; when it is to be programmed as tax table 3, enter “3”;
and when it is to be programmed as tax table 4, enter “4”.
*2 If the rate is fractional (e.g. 4-3/8%), then the fractional portion (3/8) would be converted to its decimal
equivalent (i.e. .375) and the resulting rate of 4.375 would be entered. Note that the nominal rate (R) is
generally indicated on the tax table.

Note

If you make an incorrect entry before entering the M in programming a tax table, cancel it with the
c key; and if you make an error after entering the M, cancel it with the ı key. Then program
again from the beginning correctly.

• Limitations to the entry of minimum breakpoints
Your register can support a tax table consisting of no more than 72 breakpoints. (The number of breakpoints is
36 maximum when the breakpoint difference is $1.00 or more.) If the number of breakpoints exceeds the
register’s table capacity, then the manual entry approach should be used.

Example

Programming the sample tax table shown on the previous page as tax table 1
Key operation

Print

†
Tax rate
M
T
Q

→
→
→
→

The first
cyclic
portion
M1
(MAX point)→

1@
6@
100 @
1@
11 @
23 @
39 @
57 @
73 @
89 @
111 @

a
Note
94

You do not need to enter the trailing zeros of the tax rate (after the decimal point) but you do need
to enter the decimal point for fractions.

• If the tax is not provided for every cent, modify the tax table by setting the tax for every cent in the
following way.
When setting the tax, consider the minimum breakpoint corresponding to unprovided tax to be the same as the
one corresponding to the tax provided on a large amount.
Sample tax table
Example 8%
Tax
.00
.01
.02
.03
.04
.06
.09
.10
.11
.12
.14
.17

Minimum
breakpoint
.01
.11
.26
.47
.68
.89
1.11
1.26
1.47
1.68
1.89
2.11

Modification of the left tax table
Minimum
breakpoint

Tax
.00
.01
.02
.03
.04
.05
.06
.07
.08
.09
.10
.11
.12
.13
.14
.15
.16
.17

T

.01
.11
.26
.47
.68
.89
.89
1.11
1.11
1.11
1.26
1.47
1.68
1.89
1.89
2.11
2.11
2.11

Q

M1

M2

Breakpoint
difference (¢)
1
10 (0.11-0.01)
15 (0.26-0.11)
21 (0.47-0.26)
21 (0.68-0.47)
21 (0.89-0.68)
0 (0.89-0.89)
22 (1.11-0.89)
0 (1.11-1.11)
0 (1.11-1.11)
15 (1.26-1.11)
21 (1.47-1.26)
21 (1.68-1.47)
21 (1.89-1.68)
0 (1.89-1.89)
22 (2.11-1.89)
0 (2.11-2.11)
0 (2.11-2.11)

B: Non-cyclic

C: Cyclic-1

D: Cyclic-2

From the modified tax table above;
Rate = 8(%), T = $0.01 = 1¢, Q = $0.11 = 11¢, M1 = 1.11, M2 = 2.11, M = 100

95

Job-Code-Based Programming
This section illustrates how to program items using job codes. Using job codes allows you to program a wide
variety of items in comparison with direct programming.
Start this programming by entering a corresponding job code as shown below.
2110

.

@

All the items which can be programmed by the job-code-based programming are listed on this page and the
following, and those which can also be programmed by the direct programming are marked with the symbol
“ Direct ” that follows job codes.

1 Setting the date and time
Setting the date

PGM 2

2610

Direct

Enter the month (one or two digits), day (two digits), and year (four digits: 2000 – 2099) in this sequence.

Procedure
2610

.

@

Example

Date (seven or eight digits)

Ç

Key operation

Print

2610 . @
08262004 Ç

Date

Setting the time

PGM 2

2611

Direct

Set the time using the military time (24-hour) system. For example, when the time is set to 2:30 AM, enter 230;
and when it is set to 2:30 PM, enter 1430. The time is printed and displayed on the real time system.

Procedure
2611

.

Example

@

Time (max. four digits)

Key operation

Ç
Print

2611 . @
1430 Ç

Time

96

2 Setting the register and consecutive numbers
Setting the register number

PGM 2

2612

When your store has two or more registers, it is practical to set separate register numbers for their identification.
You may set them with a maximum of six digits.

Procedure
To set the register number “0”

2612

.

Example

@

Register number
(one to six digits)

Ç

To set the register number as “123456”
Key operation

Print

2612 . @
123456 Ç

Register
number

Setting the consecutive number

PGM 2

2613

The consecutive number is increased by one each time a receipt is issued.
Enter a number (one to four digits) that is one less than the desired starting number.

Procedure
To begin the count from 0001
2613

.

Example

@

A number (one to four digits) that is one
less than the desired starting number

Ç

Setting the count start number as “1001”
Key operation

Print

2613 . @
1000 Ç

Consecutive
number

97

3 Programming for the automatic tax calculation function
Your machine has an automatic tax calculation feature which allows you to program four tax tables or rates to
avoid calculating incorrect tax amounts.
Automatic tax calculations require you to program, in addition to the tax table and rate, the tax status of each
pertinent department, PLU/UPC, and function key.

The tax table (applicable to the add-on tax)

PGM 2

2710

Direct

Sample tax table
New Jersey tax table: 6%
Range of sales amount
Taxes
.00
.01

Minimum breakpoint
.01

T

.11

Q

Maximum breakpoint

A: Difference between the
minimum breakpoint and
the next one (¢)

to

.10

–

to

.22

10 (0.11 - 0.01)

.02

.23

to

.38

12 (0.23 - 0.11)

.03

.39

to

.56

16 (0.39 - 0.23)

.04

.57

to

.72

18 (0.57 - 0.39)

.05

.73

to

.88

16 (0.73 - 0.57)

to

1.10

16 (0.89 - 0.73)

to

1.22

22 (1.11 - 0.89)

.06

.89

.07

1.11

.08

1.23

to

1.38

12 (1.23 - 1.11)

.09

1.39

to

1.56

16 (1.39 - 1.23)

.10

1.57

to

1.72

18 (1.57 - 1.39)

.11

1.73

to

1.88

16 (1.73 - 1.57)

.12

1.89

to

2.10

16 (1.89 - 1.73)

.13

2.11

to

2.22

22 (2.11 - 1.89)

M1

M2

B: Non-cyclic

C: Cyclic-1

D: Cyclic-2

To program a tax table, first make a table like the right table shown above.
From the tax table, calculate the differences between a minimum break point and the next one (A). Then, from
the differences, find irregular cycles (B) and regular cycles (C and D). These cycles will show you the following
items necessary to program the tax table:
T:
Q:
M1:
M2:
M:

98

The tax amount collected on the minimum taxable amount (Q)
The minimum taxable amount
The maximum value of the minimum breakpoint on a regular cycle (C).
We call this point “MAX point.”
The maximum value of the minimum breakpoint on a regular cycle (D).
We call this point “MAX point.”
Range of the minimum breakpoint on a regular cycle: difference between Q and M1 or between M1 and
M2

Procedure

T
max. three
digits

One- or two-*1
digit number

@

.

2710

@

Q
max. five
digits

@

@

@

*2
Rate
max. six digits
(0.0001 - 99.9999%)

M
max. four
digits

@

Minimum breakpoint
max. five digits

@

Ç

Repeat until the MAX point is entered.

To delete a tax table, use the following sequence:
2710

.

@

One- or two-*1
digit number

@

@

*2
Rate
max. six digits
(0.0001 - 99.9999%)

M
max. four
digits

@ t

*1 First figure:

The first figure to be entered depends upon whether the difference between a minimum
breakpoint to be entered and the preceding minimum breakpoint is not less than $1.00 or
more than 99¢. When the difference is not less than $1.00, enter “1,” and when it is not more
than 99¢, enter “0” or nothing.
Second figure: The second figure depends upon whether your tax table is to be programmed as tax table 1,
2, 3 or 4. When your tax table is to be programmed as tax table 1, enter “1”; when it is to be
programmed as tax table 2, enter “2”; when it is to be programmed as tax table 3, enter “3”;
and when it is to be programmed as tax table 4, enter “4”.
*2 If the rate is fractional (e.g. 4-3/8%), then the fractional portion (3/8) would be converted to its decimal
equivalent (i.e. .375) and the resulting rate of 4.375 would be entered. Note that the nominal rate (R) is
generally indicated on the tax table.

Note

If you make an incorrect entry before entering the M in programming a tax table, cancel it with the
Then program
again from the beginning correctly.

c key; and if you make an error after entering the M, cancel it with the ı key.

• Limitations to the entry of minimum breakpoints
Your register can support a tax table consisting of no more than 72 breakpoints. (The number of breakpoints is
36 maximum when the breakpoint difference is $1.00 or more.) If the number of breakpoints exceeds the
register's table capacity, then the manual entry approach should be used.

Example

Programming the sample tax table shown on the previous page as tax table 1
Key operation

Print

2710 . @
1@
Tax rate →
6@
M
→
100 @
T
→
1@
Q
→
11 @
23 @
The first
39 @
cyclic
57 @
portion
73 @
89 @
M1
(MAX point)→ 111 @

a
Note

You do not need to enter the trailing zeros of the tax rate (after the decimal point) but you do need
to enter the decimal point for fractions.
99

• If the tax is not provided for every cent, modify the tax table by setting the tax for every cent in the
following way.
When setting the tax, consider the minimum breakpoint corresponding to unprovided tax to be the same as the
one corresponding to the tax provided on a large amount.
Sample tax table
Example 8%
Tax
.00
.01
.02
.03
.04
.06
.09
.10
.11
.12
.14
.17

Modification of the left tax table

Minimum
breakpoint
.01
.11
.26
.47
.68
.89
1.11
1.26
1.47
1.68
1.89
2.11

.00
.01
.02
.03
.04
.05
.06
.07
.08
.09
.10
.11
.12
.13
.14
.15
.16
.17

Breakpoint
difference (¢)

Minimum
breakpoint

Tax

.01
.11
.26
.47
.68
.89
.89
1.11
1.11
1.11
1.26
1.47
1.68
1.89
1.89
2.11
2.11
2.11

T

1
10 (0.11-0.01)
15 (0.26-0.11)
21 (0.47-0.26)
21 (0.68-0.47)
21 (0.89-0.68)
0 (0.89-0.89)
22 (1.11-0.89)
0 (1.11-1.11)
0 (1.11-1.11)
15 (1.26-1.11)
21 (1.47-1.26)
21 (1.68-1.47)
21 (1.89-1.68)
0 (1.89-1.89)
22 (2.11-1.89)
0 (2.11-2.11)
0 (2.11-2.11)

Q

M1

M2

B: Non-cyclic

C: Cyclic-1

D: Cyclic-2

From the modified tax table above;
Rate = 8(%), T = $0.01 = 1¢, Q = $0.11 = 11¢, M1 = 1.11, M2 = 2.11, M = 100

The tax rate

PGM 2

2711

Procedure
2711

.

@

A*
1 to 4

@

When the lowest taxable amount is zero
Tax rate

@

max. six digits:
0.0001 to
99.9999%

Lowest taxable amount

a

max. five digits:
1¢ to $999.99 (Note: A minimum value of 1 must be entered.)

To delete a tax rate, use the following sequence:
2711

.

@

A*
1 to 4

@

Tax rate

@

t

max. six digits:
0.0001 to
99.9999%

*A: When you program a tax rate as tax rate 1, enter “1”; when you program it as tax rate 2, enter “2”; when you
program it as tax rate 3, enter “3”; and when you program it as tax rate 4, enter “4”.

100

Example

Programming the tax rate 4% as tax rate 2 with tax exempt as 12¢
Key operation

Print

2711 . @
2@
4@
12 a

Note

• If you make an incorrect entry before pressing the third @ key in programming a tax rate, cancel
it with the c key; and if you make an error after pressing the third @ key, cancel it with the ı
key. Then program again from the beginning correctly.
• You do not need to enter the trailing zeros of the tax rate (after the decimal point), but you do
need to enter the decimal for fractions.

Doughnut tax exempt (for the Canadian tax system)

PGM 2

2715

Procedure
To program zero

2715

Note

.

@

Quantity for doughnut
tax exempt
(max. 2 digits: 1 to 99)

a

This option is available only when your register has been set up with the Canadian tax system.

Example

To program the quantity “6”
Key operation

Print

2715 . @
6a

101

4 Programming for departments
Your machine is equipped with 20 (ER-A520)/10 (ER-A530) standard departments and a maximum of 99
departments. Your machine allows you to perform the following programming for each department.

Functional programming 1

PGM 2

2110

Direct

You can set each department for:
Item validation printing
If item entries must be validated, program corresponding departments for compulsory validation printing.
Tare table number
Tare table number associated with scale entry (0 thru 9, 0: not used)
Scale entry
Program a department for scale entry allowed when your store needs automatic scale entries.
Registration type
• If an entry of a department programmed for SICS is made first, the scale will be finalized as soon as the
department key is pressed. If the entry is made after entering a department not programmed for SICS, the
sale will not be finalized until the Ç key is pressed.
• Whenever a sale is made to a department programmed for SIF, the sale is finalized as soon as the
department key is pressed.
Department type
You may program each department as one of the following three types.
• Normal department
• Hash department
A hash department is used to enter the amount of a special “sale”, such as a gift certificate sale or for the
receipt of payment for utility bills, theatre tickets, etc., i.e. “non-sales” registrations. Any amounts entered in
this department are not added to the grand total except tax amounts.
• Bottle Return (BR)
• Gas department
The gas department enables you calculate the quantity of gas sold in gallon by using a preset unit price when
the sale amount of gas is entered. (quantity of gas = sales amount entered / preset unit price)
Also gas discount can be automatically applied to the sales. (discount amount = total amount of gas x reduced
unit price for each media; cash/check/charge)

Note

If your register has not been set for “Bottle return, Hash and gas dept.” by your dealer, you cannot
program the department for those operations. So contact your dealer if you need them.

Type of unit price entry
You may select one of the following four types of unit price entry for each department.
• Open and preset
• Preset only
• Open only
• Inhibit department key

102

Procedure
To program any dept.
To program zero
2110

.

@

@

Dept. code
(1 - 99)

t

*ABCDEF

Ç

To program the next sequential dept.

*1 Item:
A

Selection:
Non-compulsory
Compulsory

Item validation printing

B
C

Tare table number
Scale entry

D

Registration type

E

Department type

F

Type of unit price entry

Example

Inhibit
Enable
Compulsory
Normal
SICS (Single Item Cash Sale)
SIF (Single Item Finalization)
Normal department
Hash department
Bottle return department
Gas department
Inhibit department key
Open only
Preset only
Open and preset

Entry:
0
1
0 thru 9 (0: not used)
0
1
2
0
1
2
0
1
2
3
0
1
2
3

Programming for department 3
Enter ABCDEF=000003 for department 3.
Key operation

Print

2110 . @
3 @ 000003 t

Ç
A thru F

103

Functional programming 2

PGM 2

2111

Direct

Sign (plus/minus)
• Assign a plus sign to departments for normal sales transactions.
• Assign a minus sign to departments for minus transactions.
Food stamp status
• Assign a food stamp status (food stamp eligible or food stamp ineligible) to each department.
Tax status (taxable 1 thru 4/non-taxable)
• When an entry of a taxable department is made in a transaction, tax is automatically computed according to
the associated tax table or rate.

Note

Tax 4 is prohibited if you use the food stamp function.

Procedure
To program any dept.
To program zero
2111

@

.

Dept. code
(1 - 99)

@

t

*ABCDEF

Ç

To program the next sequential dept.

* Item:
A
Sign (+/-)
B

Food stamp status

C

Tax 4 status

D

Tax 3 status

E

Tax 2 status

F

Tax 1 status

Example

Selection:
Plus
Minus
Ineligible
Eligible
Non-taxable
Taxable
Non-taxable
Taxable
Non-taxable
Taxable
Non-taxable
Taxable

Entry:
0
1
0
1
0
1
0
1
0
1
0
1

Programming for department 4 and 10
Enter ABCDEF=010001 for department 4.
Enter ABCDEF=100000 for department 10.
Key operation

Print

2111 . @
4 @ 010001 t
10 @ 100000 t

Food stamp
eligible and
taxable 1

Ç
Minus dept.

Note
104

When you program the last dept. code you are allowed to program, the programming sequence will
be complete with a press of the t key.

A limit amount (HALO) of entry

PGM 2

2112

Direct

You can set limit amounts (HALO: High Amount Lockout) for each department. The limit is effective for the REG
mode operations and can be overridden in the MGR mode. The HALO limit is represented by two figures as
follows:

Procedure
To program any dept.
To program zero
2112

.

@

@

Dept. code
(1 - 99)

t

*AB

Ç

To program the next sequential dept.

“AB” is the same as A × 10B.
A: Significant digit (0 through 9)
B: Number of zeros to follow significant digit (0 through 7)
For example, presetting 13 ($10.00) here means that amount entries of up to $10.00 are allowed in the REG
mode. When you preset 17, however, the upper limit amount is 99999.99.

Example

Programming HALO limit of 9000.00 (95) for dept. 1
Key operation

Print

2112 . @
1 @ 95 t

Ç
HALO

Item label PGM 2 2114
You can program a maximum of 16 characters (item label) for each department.
Select the characters you want to program, referring to section “2 How to program alphanumeric characters” in
chapter “PRIOR TO PROGRAMMING”.
Procedure
To program any dept.
To keep the current setting
2114

.

@

@

Dept. code
(1 - 99)

Character keys
(max. 16 digits)

t

Ç

To program the next sequential dept.

Example

Programming STEAK (steak) for dept. 1
Key operation

Print

2114 . @
1 @ STEAK t

Ç
105

Unit price

PGM 1

PGM 2

1110

Direct

You can program unit prices up to a maximum of six digits ($9999.99). Even if a department is not programmed
to allow the entry of preset unit prices in functional programming 1 (job #2110), the department is automatically
changed to allow the entry of preset unit prices by this programming entry.

Procedure
To program any dept.
To program zero
1110

.

@

@

Dept. code
(1 - 99)

t

Unit price
(max. 6 digits)

Ç

To program the next sequential dept.

Example

Programming $10.00 for dept. 1
Key operation

Print

1110 . @
1 @ 1000 t

Unit price

Ç

Commission group assignment

PGM 2

2115

Direct

Your machine allows you to assign a commission group (1 – 9, 0: non commission) to each department.

Procedure
To program any dept.
To program zero (for non commission)
2115

.

@

@

Dept. code
(1 - 99)

Commission group
(1 - 9)

Ç

t

To program the next sequential dept.

Example

Programming commission group 1 for dept. 1 and commission group 2 for dept. 5
Key operation

Print

2115 . @
1@1t
5@2t

Ç

106

Commission
group no.

Group number

2116

PGM 2

Direct

You can assign departments to a maximum of 9 groups (1 thru 9).
This programming enables you to take the group department sales reports.

Procedure
To program any dept.
To program zero (For non group)
2116

@

.

@

Dept. code
(1 - 99)

Group number
(0 - 9, 0: non group)

t

Ç

To program the next sequential dept.

Example

Programming the group number 1 for dept. 1 and the group number 2 for dept. 2
Key operation

Print

2116 . @
1@1t
2t

Ç

Group no.

Group text

PGM 2

2350

You can program a maximum of 8 characters (group name) for each department group.
Select the characters you want to program, referring to section “2 How to program alphanumeric characters” in
chapter “PRIOR TO PROGRAMMIN”.

Procedure
To program any group number
To keep the current setting
2350

.

Example

@

Group number
(1-9)

@

Character keys
(max. 8 digits)

t

Ç

Programming DINNER for group number 1
Key operation

Print

2350 . @
1 @ DINNER t

Ç

107

Age limitation

2180

PGM 2

If an item sold is not allowed to be sold to certain aged persons by law, program the age limitation for the
corresponding department.

Procedure
To program any dept.
To program zero (for no limitation)
2180

.

@

@

Dept. code
(1 - 99)

Ç

t

Age limitation
(1 - 99)

To program the next sequential dept.

Note

When a department for which a setting other than zero (1 to 99) has been programmed as the age
limitation is entered, the birthday entry will be enforced.

Example

Programming the age limitation “18” for dept. 2
Key operation

Print

2180 . @
2 @ 18 t

Ç
Age limitation

Print station assignment

2118

PGM 2

When you use a remote printer, please consult your dealer.

Procedure
2118

.

To program zero

@

@

Dept. code

*A B C

t

Ç

To program for the
following dept.

* Item:
A
Remote printer 1 output
B

Remote printer 2 output

C

Printing on the chit receipt

Example

Selection:
Output
Not output
Output
Not output
Yes
No

Key operation

Entry:
1
0
1
0
1
0
Print

2118 . @
9 @ 101 t

Ç
Print station

108

Department key positioning

PGM 2

2119

You can assign a department code to each key position. Each key position has a corresponding key number.
Departments may be freely selected for the number of department keys and their positions.
To assign the department to a key position, select the key number of the position.
For key number positions, refer to section “3 Standard key number layout” in chapter “KEYBOARD”.

Procedure
To program any key number
Cancellation
2119

.

@

@

Key number
(max. 3 digits)

Ç

t

Dept. code
(1 - 99)

To program the next sequential key number

Note

The key number placement is determined by your local authorized SHARP dealer.

Example

Key operation

Print

2119 . @
1@1t
2t

Ç
Key no.

Color Video Monitor (CVM) control character

PGM 2

2158

This programming enables you to assign each department with a number that can be used as a CVM control
character. This number is converted to a two-digit character code that is transmitted for use with a CVM device.

Procedure
To program any dept.
To program zero
2158

.

@

@

Dept. code
(1 - 99)

CVM control character
(0 - 255)

t

Ç

To program for the following dept.

Example

Programming 16 as CVM control character for department 1
Key operation

Print

2158 . @
1 @ 16 t

Ç
Character code converted

109

5 PLU/UPC programming
The cash register can deal PLU codes and UPC codes.
A PLU code consist of 5-digits number and leading zeros can be applied to the PLU code.
Your machine has two kinds of PLU registration methods:
Direct PLU registration: Accomplished by pressing item key (direct PLU key) directly.
Indirect PLU registration: Accomplished by making an entry of PLU code and pressing the

PLU/
UPC

key.

UPC codes are basically codes for barcode reading. With regard to the UPC codes available for this register,
please refer to "Universal Product Code(UPC) or European Article Number(EAN)" in this chapter.
For UPC codes, the cash register has a UPC master file as a standard and a dynamic UPC file as an option.
Normally you use the UPC master file for saving the data programmed for UPC codes by using job numbers.
For the data entered in the UPC learning function mode, which is details in "UPC learning function", is stored in
the dynamic UPC file if your register has (if not, the register stores the data in the UPC master file). With regard
to data stored in the dynamic UPC file, you can edit the data or if necessary you can create programming data in
the dynamic file. The data in the dynamic UPC file can download into the UPC master file.
The phrase of “Dynamic UPC file” is indicated at the right side of job codes for the programming jobs whose
data is stored in the dynamic UPC file.
Your machine provides 2000 PLU/UPC codes as a standard, and a maximum of 15000 PLU/UPC codes.
Each PLU/UPC allows you to program the following:
PLU/UPC code (PLU: max. 5 digits, UPC: 6 to 13 digits)
Associated department
When a PLU/UPC is associated with a department, the following functions of the PLU/UPC depend on the
programming for the corresponding department.
• Type (Bottle return/Hash/Normal)
• Single item cash sale/Single item finalization
• HALO (for “Open” type)
• Item validation print compulsory/non-compulsory
Unit price (max. six digits)
You will usually have unit prices programmed for individual PLUs/UPCs as PLU/UPC unit prices.
If you program unit price “0.00” for a PLU/UPC, you can enter only the selling quantity into the PLU/UPC, i.e.
the PLU/UPC can be used only as a counter.
When your register is allowed to enter multiple prices (up to 6), you can program 6 different prices for one
PLU/UPC code.
Base quantity for split-pricing entries – two digits
Program a base quantity for each PLU/UPC dedicated to split-pricing entries.
Type of unit price entry
• If “Preset only” is selected, individual PLU/UPC entries can be made by entering the assigned code and
pressing the PLU/
UPC key (or by pressing a direct PLU key without any PLU code entry, or by scanning the UPC
code).
• If “Open only” is selected, the PLU/
UPC key must be pressed after the price entry followed by the PLU code and
the PLU/
entry
(,
or
the
unit
price
must be entered before pressing a direct PLU key).
UPC
• If “Open and preset” is selected, the entries in both “Preset” and “Open” types are available.
• If the delete mode is selected, the corresponding program data for each PLU/UPC is deleted.
• If the prohibit mode is selected, the PLU/UPC code cannot be entered. This mode does not clear the
PLU/UPC program data.

110

Sign (+/-)
The function of every PLU/UPC varies according to the combination of its sign and its associate
department’s sign as follows:
Sign

Function of PLU/UPC

Dept.

PLU/UPC

+

+

Serves as a normal plus PLU/UPC

–

–

Serves as a normal minus PLU/UPC

+

–

Accepts store coupon entries, but not split-pricing entries.

–

+

Not valid; not accepted.

Food stamp status and tax status (taxable 1, 2, 3 and/or 4, non-taxable)
Item label (max. 16 characters)
Tare table number and scale entry
Age limitation
Commission group (1 to 9)
PLU/UPC group (1 to 99) and group text (max. 8 characters)
Mix-and-match table (max. 10 tables)
Condiment table (max. 99 tables)
Set PLU (for only PLU)
You can link a maximum of 10 PLUs to a particular PLU.
Link PLU/UPC link
A PLU/UPC is able to link to any other PLU (e.g. bottle deposit). However, the number of links is a
maximum of 5. Even if more than 5 PLUs are linked, the sixth or higher link is not actualized (ignored).
Print station
Delete period for non-accessed UPC codes
Non-PLU code format
PLU level assignment and direct PLU key positioning
Stock quantity
Item label for remote printer (max. 12 characters)
Control character for color video monitor

Note

For some items, you can program in two ways: programming an individual PLU code and for a
range of sequential PLU codes. The procedure marked “For each PLU” shows individual PLU
programming. The procedure marked “For a range of PLUs” shows sequential range PLU
programming.

Associated department

PGM 1

PGM 2

1200

2230

Direct
1050

(Dynamic UPC file)

Procedure
For each PLU/UPC
To program any PLU/UPC

Ä
1200
1050

.

@

PLU code
(max. 5 digits)
UPC code
(6 to 13 digits)

Note

@

Associated
dept. code
(max. 2 digits)

t

Ç

To program for the following PLU/UPC

As soon as the programming is completed for one PLU/UPC, the next code appears in the display.

111

For a range of PLUs

@

.

2230

Start PLU code
(max. 5 digits)

Note

To apply the current
setting of start PLU code
to PLUs within the range

@

End PLU code
(max. 5 digits)

@

t

Associated
dept. code
(1 - 99)

PLU codes must have already been defined. If not, an error message "NO RECORD" will appear
on the display.

Example

Programming for PLU 1 for “Associate department 2”

For each PLU/UPC

Key operation

Print

1200 . @
1@2t

Dept. code

Ç

Example
For a range
of PLUs

Programming the PLU 11 thru 20 for “Associate department 3”
Key operation

Print

2230 . @
11 @ 20 @
3t

Ç

112

Ç

Unit prices

PGM 1

PGM 2

1210

Direct

1060

(Dynamic UPC file)

Procedure
To program for the following PLU/UPC
To keep current setting

Ä
1210
1060

.

@

@

PLU code
(max. 5 digits)
UPC code
(6 to 13 digits)

Unit price
(max. 6 digits)

ı

Ç

* To program unit price 2 thru 6
(only when price shift function is allowed)
To program for the following PLU/UPC
To program any PLU/UPC

* In case that price shift function is allowed, the register prompts to enter a unit price for the following level by
displaying “P2” thru “P6” on the display, and when a unit price of level 6 is entered, the register goes to the
status for programming the following PLU/UPC. When you press the Ç on the way of programming multiple
prices for a PLU/UPC code, prices for the remained levels are kept unchanged.
In case that single price entry is allowed for a PLU/UPC code, the register goes to the status for programming
the following PLU/UPC.

Note

The preset amount will work as the unit price for the “Preset” type and as the HALO amount for the
“Open” type. In the case of the “Open” type, zero preset prevents amount entry and a 9999.99
preset is the maximum limitation. In the case of the “Preset” type zero and 9999.99 preset have no
special meaning. (i.e. 0 amount preset is available.)

Example

Programming “$1.25, $1.50, $2.00, $2.50, $3.00, $4.00” for price level 1 thru 6 of PLU1
Key operation

Print

1210 . @
1 @ 125 t
150 t
200 t
250 t
300 t
400 t

Unit price

Ç

113

Base quantity

PGM 1

PGM 2

1211

Direct

1061

(Dynamic UPC file)

Procedure
To program any PLU/UPC

Ä

@

.

1211
1061

Example

To program zero

@

PLU code
(max. 5 digits)
UPC code
(6 to 13 digits)

Ç

t

Base q’ty
(max. 2 digits)

To program for the following PLU/UPC

Programming “12” for PLU 2
Key operation

Print

1211 . @
2 @ 12 t
Base q'ty

Ç

Functional programming 1

PGM 2

2210

2231

Direct

2060

(Dynamic UPC file)

Procedure
For each PLU/UPC
To program any PLU/UPC

Ä

.

2210

@

2060

PLU code
(max. 5 digits)

@

UPC code
(6 to 13 digits)

To program zero
*ABCDEFG

t

Ç

To program for the following PLU/UPC

For a range of PLUs

.

2231

Start PLU code
(max. 5 digits)

Note

114

@
@

To apply the current
setting of start PLU code
to PLUs within the range
End PLU code
(max. 5 digits)

@

*ABCDEFG

t

Ç

When new PLU codes are created in the range specified, the default values are applied to the
programming items other than the items set in this programming.

* Item:
A
Delete method (for only UPC)
For PLU, always enter 1.

B

D

Condiment type PLU (for only PLU)
For UPC, always enter 0.
Condiment entry (for only PLU)
For UPC, always enter 0.
Price shift entry

E
F

Tare table number
Scale entry

G

Type of unit price entry

C

Example

Selection:
Delete in non-accessed UPC
deleting job (#105 in Z1 mode)
Inhibit to delete in non-accessed
UPC deleting job (#105 in Z1 mode)
Disable
Enable
Allowed
Compulsory
Enable
Inhibit
Compulsory

Entry:
0
1

0
1
0
1
0
1
2
0 thru 9 (0: Not used)
Inhibit
0
Enable
1
Compulsory
2
Prohibit mode
0
Open price only (for only PLU)
1
Preset price only
2
Open price and preset price (for only PLU)
3
Delete mode
4

To program ABCDEFG=1000003 for PLU1

For each PLU/UPC

Key operation

Print

2210 . @
1 @ 1000003 t

Ç

A thru G

To program ABCDEFG=1000003 for PLU11 thru 20
For a range
of PLUs

Key operation

Print

2231 . @
11 @ 20 @
1000003 t

Ç

115

Functional programming 2

2211

PGM 2

2232

Direct

2061

(Dynamic UPC file)

Procedure
To program any PLU/UPC

For each PLU/UPC

Ä

.

2211

@

2061

To program zero

@

PLU code
(max. 5 digits)
UPC code
(6 to 13 digits)

*ABCDEF

t

Ç

To program for the following PLU/UPC

For a range of PLUs

.

2232

Start PLU code
(max. 5 digits)

Note

@
@

116

End PLU code
(max. 5 digits)

@

*ABCDEF

t

Ç

For a range of PLUs: PLU codes must have already been defined. If not, an error message "NO
RECORD" will appear on the display.

* Item:
A
Sign (+/-)
B

Food stamp status

C

Tax 4 status

D

Tax 3 status

E

Tax 2 status

F

Tax 1 status

Note

To apply the current
setting of start PLU code
to PLUs within the range

Selection:
Plus
Minus
Ineligible
Eligible
Non-taxable
Taxable
Non-taxable
Taxable
Non-taxable
Taxable
Non-taxable
Taxable

Entry:
0
1
0
1
0
1
0
1
0
1
0
1

Tax status (taxable 1 thru 4/non-taxable)
Tax 4 is prohibited if you use the food stamp function.
A PLU/UPC not programmed for Tax 1 thru Tax 4 statuses is registered depending on the tax
status of the department which the PLU/UPC belongs to.

Example

Programming ABCDEF=010001 for PLU 1

For each PLU/UPC

Key operation

Print

2211 . @
1 @ 010001 t

Ç

Taxable 1
Food stamp
eligible

Programming the range PLU 11 thru 20 for ABCDEF=000001
For a range
of PLUs

Key operation

Print

2232 . @
11 @ 20 @
000001 t

Ç

117

Item label

PGM 2

2214

2064

(Dynamic UPC file)

You can program a maximum of 16 characters (item label) for each PLU/UPC.
Select the characters you want to program, referring to section “2 How to program alphanumeric characters” in
chapter “PRIOR TO PROGRAMMING”.

Procedure
To program any PLU/UPC

Ä
2214
2064

.

@

PLU code
(max. 5 digits)

@

UPC code
(6 to 13 digits)

To keep the current setting
Character keys
(max. 16 digits)

t

Ç

*To program for price levels 2 thru 6
(only when price shift function is allowed)
To program for the following PLU/UPC

* In case that price shift function is allowed, the register prompts to enter an item level for the following level by
displaying "P2" thru "P6" on the display, and when an item level of level 6 is entered, the register goes to the
status for programming the following PLU/UPC. You must enter texts for all price levels.
In case that single price entry is allowed for a PLU/UPC code, the register goes to the status for programming
the following PLU/UPC.

Example

Programming “MILK_1, MILK_2, MILK_3, MILK_4, MILK_5, MILK_6” for price levels 1 thru 6
of PLU1
Key operation

Print

2214 . @
1 @ MILK_1 t
MILK_2 t
MILK_3 t
MILK_4 t
MILK_5 t
MILK_6 t

Ç

118

Commission groups

PGM 2

2215

2235

Direct

2065

(Dynamic UPC file)

You can assign PLUs/UPCs to commission groups (1 to 9).

Procedure
For each PLU/UPC

To program any PLU/UPC

Ä

@

.

2215
2065

@

PLU code
(max. 5 digits)
UPC code
(6 to 13 digits)

To program zero
Commission group
(0 - 9, 0: non commision)

t

Ç

To program for the following PLU/UPC

For a range of PLUs

@

.

2235

Start PLU code
(max. 5 digits)

Note

@

To apply the current setting of
start PLU code to PLUs within the range

@

End PLU code
(max. 5 digits)

Commission group
(0 - 9, 0:non commision)

t

Ç

For a range of PLUs: PLU codes must have already been defined. If not, an error message "NO
RECORD" will appear on the display.

Example

Programming the commission group 1 for PLU 1

For each PLU/UPC

Key operation

Print

2215 . @
1@1t

Ç

Commission
group no.

Programming all of PLU 11 thru 20 for the commission group 1
For a range
of PLUs

Key operation

Print

2235 . @
11 @ 20 @
1t

Ç

119

Group number

2216

PGM 2

2066

(Dynamic UPC file)

You can assign PLU/UPCs to a maximum of 99 groups. Each PLU/UPC can belong to a maximum of three
groups.

Procedure

2216
2066

To program any PLU/UPC

@

.

PLU code
(max. 5 digits)
UPC code
(6 to 13 digits)

Ä

To program zero

@

*ABCDEF

t

Ç

To program for the following PLU/UPC

* AB: Group number (0 to 99) for group 1
CD: Group number (0 to 99) for group 2
EF: Group number (0 to 99) for group 3

Example

Programming 01/10/50 (Group 1/2/3) for PLU1
Key operation

Print

2216 . @
1 @ 011050 t

Ç

Group nos.

Group text

PGM 2

2351

You can program a maximum of 8 characters (group name) for each PLU/UPC group.
Select the characters you want to program, referring to section “2 How to program alphanumeric characters” in
chapter “PRIOR TO PROGRAMMING”.

Procedure

To program any group number
To keep the current setting

2351

.

Example

@

Group number
(1-99)

Character keys
(max. 8 digits)

Programming DRINK for group number 1
Key operation

Print

2351 . @
1 @ DRINK t

Ç
120

@

t

Ç

Age limitation

PGM 2

2280

2236

2081

(Dynamic UPC file)

If an item sold is not allowed to be sold to certain aged persons by law, program the age limitation for the
corresponding PLU/UPC.

Procedure
For each PLU/UPC
To program any PLU/UPC

Ä

@

.

2280
2081

To program zero (for no limitation)

@

PLU code
(max. 5 digits)
UPC code
(6 to 13 digits)

t

Age limitation
(1 - 99)

Ç

To program for the following PLU/UPC

For a range of PLUs

@

.

2236

Start PLU code
(max. 5 digits)

Note

To apply the current
setting of start PLU code
to PLUs within the range

@

End PLU code
(max. 5 digits)

@

Age limitation
(0 - 99, 0: no limitation)

t

Ç

• PLU codes must have already been defined. If not, an error message "NO RECORD" will appear
on the display.
• When a PLU/UPC for which a setting other than zero (1 to 99) has been programmed as the age
limitation is entered, the birthday entry will be enforced.

Example

Programming the age limitation “18” for PLU 2

For each PLU/UPC

Key operation

Print

2280 . @
2 @ 18 t

Ç

Age limitation

121

Programming the PLU 11 thru 20 for the age limitation “18”
For a range
of PLUs

Key operation

Print

2236 . @
11 @ 20 @
18 t

Ç

Stock quantity

PGM 1

1222

PGM 2

1220

1221

You can assign a stock quantity to each PLU/UPC code. (If you want to control a stock quantity, please consult
your dealer.) When you assign it for the first time, follow the below procedure:

Procedure
To program any PLU/UPC

Ä
1222

.

@

@

PLU code
(max. 5 digits)
UPC code
(6 to 13 digits)

Example

To clear the stock quantity

Ç

t

Stock q’ty
(max. 7 digits)

To program for the following PLU/UPC

To program the stock quantity “10” for PLU 2
Key operation

Print

1222 . @
2 @ 10 t

Ç
Stock q ty

Note

• If you assign another stock quantity to the PLU/UPC code which you have assigned a stock
quantity to, it will be overridden.
• You must use a decimal point (.) key when setting quantities that are fractional.

If you need to add or subtract a stock quantity, follow the below procedure:

Procedure
To program any PLU/UPC

Ä
Addition:

1220

Subtraction: 1221

122

.

@

PLU code
(max. 5 digits)
UPC code
(6 to 13 digits)

@

Stock q ty to be
added or subtracted
(max. 7 digits)

t

To program for the following PLU/UPC

Ç

Adding the stock quantity

Example

To add the stock quantity “4” to the current stock quantity “10” of PLU2
Key operation

Print

1220 . @
2@4t

Ç

Added stock
q’ty

Subtracting the stock quantity

Example

To subtract the stock quantity “1.5” from the current stock quantity “14” of PLU 2
Key operation

Print

1221 . @
2@1.5t

Ç

Set PLU

PGM 2

Subtracted
stock q’ty

2221

Procedure
To program any PLU
Cancellation

t

To repeat up to 10 times
2221

.

@

PLU code
(max. 5 digits)

@

Tied PLU code
(max. 5 digits)

t
t

Ç

To program the next sequential PLU

Note

PLU codes must have already been defined.
You can program a maximum of 15 set PLUs. A set PLU can be tied to a maximum of 10 PLUs.

Example

Programming the set PLU 20 (tied PLUs: PLU 201 and PLU 202)
Key operation

Print

2221 . @
20 @ 201 t
202 t

Ç

Tied PLUs

123

Mix-and-match table

PGM 2

2217

2225

2067

(Dynamic UPC file)

The mix-and-match table consists of the adjustment amount and the matching count for discount (satisfying the
count of entered items). You can program a maximum of 99 mix-and-match tables. One table can be assigned
maximum of 5 kind of items.
[Ex.]

Mix-and-match table no. 1: matching count=3, adjustment amount $7.00
Mix-and-match items of table no. 1: Item-A ($2.30), Item-B ($3.10), Item-C ($2.50)

Item-A $2.30
Item-A $2.30
Item-B $3.10
Subtotal
(Discount
Total

$7.70
$0.70)
$7.00


Item-C $2.50
Item-C $2.50
Item-C $2.50
Subtotal
(Discount
Total


Item-A $2.30
Item-B $3.10
Item-C $2.50

$7.50
$0.50)

Subtotal
(Discount

$7.00

Total

$7.90
$0.90)
$7.00

Programming of matching count and adjustment amount

Procedure
To program any other table
Cancellation
2225

.

@

Table no.
(1 - 99)

@

t

*ABCDEFGH

Ç

* AB:
Matching count (1 - 99)
CDEFGH: Adjustment amount (max. 6 digits)

Example

Programming mix-and-match table no.1 (matching count=3, adjustment amount $5.00)
Key operation

Print

2225 . @
1 @ 03000500 t
Adjustment
amount

Ç
Matching count

Assigning items to the mix-and-match tables

Procedure
To program any PLU/UPC

Ä
2217
2067

124

.

@

PLU code
(max. 5 digits)
UPC code
(6 to 13 digits)

@

To program zero
Table no.
(1 - 99)

t

To program for the following PLU/UPC

Ç

Example

Programming mix-and-match table no.1 for PLU 1
Key operation

Print

2217 . @
1@1t

Ç

Mix-andmatch
table no.

PLU condiment table

PGM 2

2222

2223

The “condiment entry” is intended to guide the operator in making menu entries which require special cooking
instructions. For example, a cashier/server can make such entries as “garnishing potato,” “with salad,” and
“grilling steak rate.” When a cashier/server enters a menu-item PLU to which PLUs for the condiment entry have
been assigned, these orders (such as “garnishing potato”) will be printed on the receipt and conveyed to the
kitchen.
Before you program for the condiment entry, prepare a condiment table. The following shows an example of
a condiment table:
Condiment table
Table
number
01
02

04
99

PLU codes for condiment entry (programmed text)
Message text
(HOWCOOK?)
Message text
(WITH?)

23
(RARE)
44
(SALAD)

Message text
(POTATO?)
Message text
(DRINK?)

33
(P.CHIPS)
63
(TEA)

27
25
(MED.RARE) (WELLDONE)
45
(FRUITS)

37
(MASHED.P)
65
(MILK)

38
(BAKED.P)
67
(A.JUICE)

PLUs (Up to 15 for a table)

02

Condiment
tables
(Up to 99)
99

Next condiment
table number

125

The condiment table should contain the following:
Condiment table: The condiment table is a group of condiment PLUs, which is assigned to each menuitem PLU.
A table consists of a message text and up to 15 PLUs. Also, you can assign the next
condiment table number to a condiment table to link them.
The message text is used for displaying a prompting message. The PLU is used for the
special order setting. For example, when a server enters a menu-item PLU, a display
message programmed for the message text such as “HOWCOOK?.” will appear. Then specify
one of the PLU programmed for text such as “RARE.”
Table number:
The table number is intended to identify each condiment table.
Assigning PLU condiment table number

Procedure
To program zero
2222

.

@

@

PLU code
(max. 5 digits)

Condiment table#
(0 - 99, 0: not used )

t

Ç

To program for the following PLU code
To program any PLU

Example

Programming condiment table #1 for PLU 15
Key operation

Print

2222 . @
15 @ 1 t

Ç

Condiment
table #

126

Assigning PLUs for condiment entry

Procedure

@

.

2223

To delete

@

Condiment table#
(1 - 99)

@

*ABC

After repeating 15 times

t

PLU code
(max. 5 digits)

t

Ç

To repeat up to 15 times
To program any other table

*A: Repeat times (1 to 9)
BC: Next table# (00 to 99: 00: not applied)

Example

Programming repeat time 1 and next condiment table #2 and PLU 23/24/25 for PLUs for
condiment entry for condiment table #1.
Key operation

Print

2223 . @
1@
102 @
23 t
24 t
25 t

Matching count
Repeat times

t
Ç
Note

Next table #

PLU codes must have been already defined.

Print station to PLU/UPC assignment

PGM 2

2218

2068

(Dynamic UPC file)

When you use a remote printer, consult your dealer.

Procedure
Scan UPC code

Ä
2218

.

@

2068

PLU code
(max. 5 digits)
UPC code
(6 to 13 digits)

To program zero

@

*ABC

t

Ç

To program for the following PLU/UPC
To program any PLU/UPC

* Item:
A
Remote printer 1 output
B

Remote printer 2 output

C

Printing on the chit receipt

Selection:
Output
Not output
Output
Not output
Yes
No

Entry:
1
0
1
0
1
0

127

Example

Key operation

Print

2218 . @
9@
101 t

Ç

Print
station

Delete period for non-accessed UPC codes

PGM 2

2029

You can delete the UPC codes which have not been accessed during the period you set in this program when
you execute the job #105 in Z1 mode when you set “Delete in non-accessed UPC deleting job” in the UPC
delete method (#2210).

Procedure
To program “00”
2029

.

@

Delete period *
(1 to 99 days)

Ç

* When you select “00” for the period, no UPC code is deleted by the non-accessed UPC deleting job.

Example
Key operation

2029 . @
60 Ç

128

Print

Programming Non-PLU code format

2025

PGM 2

The register allows you to specify the Non-PLU code format (flag code: 2, 02, 20 -29).
The format data is as follows:
C

Flag
(02 or 20-29)

C

2

D

Free format

D

Free format
Flag
Price check digit

Field 1
Field 2
Free format area

Procedure
To delete

2025

.

`

*1

`

Flag code
(max. 2 digits)

*1 Flag code: 2, 02, 20 - 29
*2 Item:

*2
ABCDEF

Selection:

A
B
C
D

Length of field 1 (number of digits)
Length of field 2 (number of digits)
Always enter 0.
Meaning of field 2*3

E

Price check digit used

F

TAB or decimal point of field 2 (0, 1, 2, 3)

ı

c

Entry:
0-9
0-9
0
2
0
1
0
0-3

(Fixed position)
Quantity
Price
Yes
No

*3: When you preset a quantity, the sales amount is calculated as follows: quantity x unit price programmed in
#1210.

Example

P

2 0
Flag
code

C

D

PLU no.

D

Price

Price check digit

(TAB2)

Key operation

Print

2025 . `
20 `
540012 ı

ABCDEF

c

Flag code

129

Link PLU/UPC link

2220

PGM 2

Procedure
To program any PLU/UPC
Cancellation

Ä
2220

.

@

@

PLU code
(max. 5 digits)

t

To repeat up to 5 times

Ç

t
t

Linked PLU code
(max. 5 digits)

UPC code
(6 to 13 digits)

To program for the following PLU/UPC

Note

PLU/UPC codes must have already been defined.
You can program a maximum of 15 link PLUs/UPCs. A link PLU/UPC can be linked to a maximum
of 5 PLUs.

Example

Programming so that PLU 25, 26 and 27 are linked to PLU 21
Key operation

Print

2220 . @
21 @ 25 t
26 t
27 t

Linked
PLUs

Ç
Programming of PLU levels and direct PLU keys

PGM 2

2219

You can assign PLU codes to fixed keys in each PLU level and use those keys as direct PLU key.
For assigning a PLU level, press the l, ¬, Ò,

L4

or

L5

key or enter level number and press the ä key.

For example, if you want to assign PLU level 1 and key no. 1 to a PLU code, press the l key and enter 1
before entering the PLU code.
For key no. position, refer to section “3 Standard key number layout” in chapter “KEYBOARD”.

Procedure
To program any key no.
Level no.
(1-5)

2219

. @

ä

l
¬
Ò

Cancellation
Key no.
(max. 3 digits)

@

PLU code
(max. 5 digits)

t Ç

To program the next sequential key no.

L4
L5
To keep the current level

Note
130

• PLU codes must have already been defined.
• The key number placement is determined by your local Authorized SHARP Dealer.

Example

Programming of PLU 1 (level 1) and PLU 65 (level 2) are assigned to key no. 21
Key operation

Print

2219 . @
21
l @ 1t
¬ 21 @ 65 t

Ç
Key no.

Item label for remote printer

PGM 2

2244

2094

(Dynamic UPC file)

You can program a maximum 12 characters (item label) for each PLU/UPC which are printed by remote printers.
Select the characters you want to program, referring to section “2 How to program alphanumeric characters” in
chapter “PRIOR TO PROGRAMMING”.

Procedure
To program any PLU/UPC

Ä
2244
2094

.

@

@

PLU code
(max. 5 digits)
UPC code
(6 to 13 digits)

To keep the current setting

t

Character keys
(max. 12 digits)

Ç

*To program for price levels 2 thru 6
(only when price shift function is allowed)
To program for the following PLU/UPC

* In case that price shift function is allowed, the register prompts to enter a remote printer item level for the
following level by displaying “P2” thru “P6” on the display, and when an item level of level 6 is entered, the
register goes to the status for programming the following PLU/UPC. You must enter texts for all price levels.
In case that single price entry is allowed for a PLU/UPC code, the register goes to the status for programming
the following PLU/UPC.

Example

Programming “MILK_K1, MILK_K2, MILK_K3, MILK_K4, MILK_K5, MILK_K6” for price levels
1 thru 6 of PLU1
Key operation

Print

2244 . @
1 @ MILK_K1 t
MILK_K2 t
MILK_K3 t
MILK_K4 t
MILK_K5 t
MILK_K6 t

Ç

131

Color Video Monitor (CVM) control character

PGM 2

2258

2234
2059

(Dynamic UPC file)

This programming enables you to assign each PLU/UPC with a number that can be used as a CVM control
character. This number is converted to a two-digit character code that is transmitted for use with a CVM device.

Procedure
To program any PLU/UPC

For each PLU/UPC

Ä

@

.

2258
2059

@

PLU code
(max. 5 digits)
UPC code
(6 to 13 digits)

To program zero
CVM control character
(0 - 255)

Ç

t

To program for the following PLU/UPC

For a range of PLUs

@

.

2234

Start PLU code
(max. 5 digits)

@

To apply the current setting of
start PLU code to PLUs within the range

@

End PLU code
(max. 5 digits)

CVM control character
(0 - 255)

t

Ç

For a range of PLUs: PLU codes must have already been defined. If not, an error message "NO
RECORD" will appear on the display.

Note

Example

Programming 16 as CVM control character for PLU1

For each PLU/UPC

Key operation

Print

2258 . @
1 @ 16 t

Ç

Character code
converted

Programming the range PLU11 through 20 for CVM control character 16
For a range
of PLUs

132

Key operation

Print

2234 . @
11 @ 20 @
16 t

Ç

6 Programming for miscellaneous keys
Only function keys which you have allocated on the keyboard will allow this programming.

Rate (%, ç, commission, gratuity,
1310

CA
TIP

,

CH
TIP

) and discount (-)

PGM 1

PGM 2

Direct

You can program percent rates, currency conversion rates, commission rate, gratuity rate, tip-in rate and
discount amount.

Procedure

1310

@

.

*1
Function no.

@

To program zero
*2
Rate or amount

s

a

To program any function

*1: Function no.
1: For the - key
2: For the – key
3: For the — key
4: For the ≠ key
5: For the ± key
6: For the % key
(∞)

7: For the § key
8: For the ¶ key
9: For the • key
10: For the ∞ key
106: For the ç key
107: For the " key
108: For the # key

173: For the commission sale 1
174: For the commission sale 2
175: For the commission sale 3
176: For the commission sale 4
177: For the commission sale 5
178: For the commission sale 6
179: For the commission sale 7

180: For the commission sale 8
181: For the commission sale 9
87: For the gratuity
CA
CH
141: For the TIP
and TIP
keys
(tip-in)

*2: Rate or amount
0 — 999999 (Discount amount)
0.00 — 100.00 (% rate)
0.0000 — 9999.9999 (Currency conversion rate)
0.00 — 999.99 (Commission rate)
0.00 — 100.00 (Gratuity rate)
0.00 — 100.00 (Tip-in rate)

Example

Assigning $10.00 to the - key, 10.25% to the % key, and 1.325 to the ç key.
Key operation

Print

1310 . @
1 @ 1000 ı
6 @ 10 . 25 ı
106 @ 0 . 8063 ı

Discount amount
Percent rate

a
Conversion rate

Note

• You must use a decimal point when setting percentage rates that are fractional.
• When amount entry is selected for tip-in entry on the programming job #2616, you cannot
program for function number 141.

133

Gas discount unit price

PGM 1

PGM 2

1311

Procedure
To program any function
To program zero
1311

.

@

Price *
(0.0 - 99.9 cent)

@

*Function no.

t

Ç

*Decimal point is not necessary.

*: Function no.
11:Gas discount when finalized by a
12:Gas discount when finalized by Å
13:Gas discount when finalized by 3
14:Gas discount when finalized by 4
15:Gas discount when finalized by É
16:Gas discount when finalized by k
17:Gas discount when finalized by CHK2
18:Gas discount when finalized by CHK3
19:Gas discount when finalized by CHK4
20:Gas discount when finalized by CHK5

Example

21:Gas discount when finalized by (
22:Gas discount when finalized by )
23:Gas discount when finalized by *
24:Gas discount when finalized by +
25:Gas discount when finalized by ,
26:Gas discount when finalized by 6
27:Gas discount when finalized by 7
28:Gas discount when finalized by 8
29:Gas discount when finalized by 9

Programming 50.5 cents for gas discount unit price when finalized by a

Key operation

Print

1311 . @
11 @ 505 t

Ç

Currency description text (ç)

PGM 2

2334

You can program a maximum of 4 characters for each of the ç thru $ keys.

Procedure
To program any conv. function
To keep the current setting
2334

.

@

*: Function no.
106: For the ç key
107: For the " key

134

*Function no.

108: For the # key
109: For the $ key

@

Character keys
(max. 4 digits)

t

Ç

Programming “Ÿ” for the " key

Example

Key operation

Print

2334 . @
106 @ / / /
207 º


Entry using
character code 

t
Ç

Currency description text




A limit amount (HALO) of entry (-, † (for manual tax),
2312

CA
TIP

,

CH
TIP

, r, p)

PGM 2

Direct

The HALO limit is in effect for the REG-mode operations but can be overridden in the MGR mode. The HALO
limit is represented by two figures as follows:

Procedure
To program zero
2312

@

.

*1
Function no.

@

*2
AB

s

a

To program any function

*1: Function no.
1: For the - key
2: For the – key
3: For the — key
4: For the ≠ key
5: For the ± key

53: For the † key
95: For the r key
96: For the ® key
97: For the p key
98: For the π key

141:For the

CA
TIP

and

CH
TIP

key

*2: AB is the same as A x 10B.
A: Significant digit (0 through 9)
B: Number of zeros to follow significant digit
0 through 7 (for the - thru ±, †,

CA
TIP

and

CH
TIP

keys)

0 through 8 (for the r, ®, p, and π keys)
For example, presetting 13 ($10.00) here means that amount entries of up to $10.00 are allowed in the REG
mode.
CA
CH
You can set up AB = 17 for no limitation (for the - thru ±, †, TIP
and TIP
keys).
You can set up AB = 18 for no limitation (for the r, ®, p, and π keys).

Example

Programming 13 for the - key.
Key operation

Print

2312 . @
1 @ 13 ı

a

HALO limit

135

+/- sign, food stamp status, and tax status (%, -, gratuity)

PGM 2

2311

Direct
+/- sign:
Programming of the +/- sign assigns the premium or discount function for each key.
Food stamp status: Programming of the food stamp status decides whether a premium or discount should be
dealt with as a food stamp-eligible amount or not.
Tax status:
Programming of the tax status decides whether a premium or discount should be dealt with
as a taxable (taxable 1/2/3/4) or non-taxable amount.

Note

Tax 4 is prohibited if you use the food stamp function.

Procedure
To program any function
To program zero
2311

@

.

*1: Function no.
1: For the - key
2: For the – key
3: For the — key
4: For the ≠ key
5: For the ± key

*1

6: For the %(∞) key
7: For the § key
8: For the ¶ key
9: For the • key
10: For the ∞ key

*2: Item:
A

(+/-) sign

B

Food stamp status

C

Tax 4 status

D

Tax 3 status

E

Tax 2 status

F

Tax 1 status

Example

@

Function no.

*2

s

ABCDEF

87: For the gratuity

Selection:
Plus
Minus
Ineligible
Eligible
Non-taxable
Taxable
Non-taxable
Taxable
Non-taxable
Taxable
Non-taxable
Taxable

Entry:
0
1
0
1
0
1
0
1
0
1
0
1

Programming ABCDEF=100001 for the % key and ABCDEF=000000 for the § key
Key operation

Print

2311 . @
6 @ 100001 ı
7 @ 000000 ı

a
Taxable 1

136

a

Percent entry type (%)

2310

PGM 2

You can program the entry type of rates for percent entries.

Procedure
To program any percent function
To program zero
2310

.

@

*1: Function no.
6: For the %(∞) key
7: For the § key
8: For the ¶ key
9: For the • key
10: For the ∞ key

Example

*1

Function no.

@

*2

Entry type

s

a

*2: Entry type
0: Inhibited entry
1: Open rate only
2: Preset rate only
3: Open rate and preset rate

Programming “Preset rate only” for the § key
Key operation

Print

2310 . @
7@2ı

a
Preset rate only

137

Item% or subtotal% selection (%)

PGM 2

2315

Direct

Item%: Select this when a percent calculation is desired for the individual department and PLU/UPC.
Subtotal%: Select this when a percent calculation is desired for merchandise subtotals.

Procedure
To program any percent function
To program zero
2315

.

@

*1: Function no.
6: For the %(∞) key
7: For the § key
8: For the ¶ key
9: For the • key
10: For the ∞ key

Example

*1
Function no.

*2

@

A

s

a

*2: A
0: Subtotal%
1: Item%

Programming “Item%” for the § key
Key operation

Print

2315 . @
7@1ı

a
Item%

Percent rate limitation (%)

PGM 2

2313

You can program the upper limit of percent rates for percent entries.
Percent entries that use the upper limit may be overridden in the MGR mode.

Procedure
To program any percent function
To program zero
2313

.

@

*1: Function no.
6: For the %(∞) key
7: For the § key

Note

*1
Function no.

8: For the ¶ key
9: For the • key
10: For the ∞ key

@

*2
Rate limitation

s

a

*2: Rate limitation
0.00 – 100.00 (Entering 0.00 inhibits the
open percent rate entry)

The . key is needed only for fractional entry.

Example

Programming the limit to 15.5% for the § key
Key operation

Print

2313 . @
7 @ 15 . 5 ı

a
138

Limitation

Vendor or store coupon selection (-)

2316

PGM 2

Direct

Vendor coupon: Select this when the coupon is to be applied to the total sales amount.
Store coupon: Select this when the coupon is to be applied to an individual department or PLU.

Procedure
To program any coupon function
To program zero
2316

@

.

*1: Function no.
1: For the - key
2: For the – key
3: For the — key

Example

*1
Function no.

4: For the ≠ key
5: For the ± key

@

*2

A

s

a

*2: A
0: Vendor coupon (subtotal â)
1: Store coupon (item â)

Programming the “Store coupon” for the – key.
Key operation

Print

2316 . @
2@1ı

a
Item â

139

7 Programming for the media keys
Functional programming 1

PGM 2

2320

Direct

You can set each media for:
GLU/PBLU/Manual PB/CB entry compulsory
Short amount tender entry
Retention of closed GLU/PBLU file
Bill (slip) print compulsory
Footer printing on receipt
This programming decides whether or not your machine should print a message at the foot of a receipt when a
specified media key is used.
Non-add code compulsory
You can enforce the non-add code entry when a media entry is accepted.
Change enable (over tender enable)
Either change enable or disable can be selected for a corresponding media key.
Validation printing compulsory
If media entries must be validated, set the corresponding media for compulsory validation print.
Drawer opening
You can program each media key to or not to open the drawer.
Amount tendered compulsory
You may select amount tendered compulsory or optional for the a, Å thru É, k, and CHK2 thru CHK5 keys.
You may select amount tendered compulsory or inhibited for the ( thru CH9 keys.

Procedure
To program any media function
To program zero
2320

.

@

*1

Function no.

@

*2

ABCDEFGHIJ

*1: Function no.
89: For the a key
90: For the Å key
91: For the Å
3 key
92: For the Å
4 key
93: For the É key
114: For the ( key
116: For the ) key
118: For the * key

140

120: For the + key
122: For the , key
124: For the ,6 key
126: For the ,7 key
128: For the ,8 key
130: For the ,9 key
132: For the k key
CHK2 key
133: For the ,

CHK3 key
134: For the ,
CHK4 key
135: For the ,
CHK5 key
136: For the ,
82: For the S key
94: For the f key
238: For the ≥ key

s

a

*2: Item:
A
GLU/PBLU/Manual PB/CB entry

B

Short amount tender entry

C

Retention of closed GLU/PBLU file

D

Bill (slip) printing

E

Footer printing on receipt

F

Non-add code entry

G

Change enable (over tender enable)

H

Validation printing

I

Drawer opening

J

Amount tendered operation

Note

Selection:
Enable
Inhibit
Compulsory
Enable
Disable
No
Yes
Non-compulsory
Compulsory
No
Yes
Non-compulsory
Compulsory
Enable
Disable
Non-compulsory
Compulsory
Yes
No
Optional amount tendered for cash or check
Inhibit amount tendered for charge
Compulsory amount tendered

Entry:
0
1
2
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
0
1

• For the S or ≥ key, always enter 0 as A thru C and E thru J.
• For the f key, always enter 0 as B, G, and J.

Example

Programming of the * key for ABCDEFGHIJ=0000000001
Key operation

Print

2320 . @
118 @
0000000001 ı

a
A thru J

141

Functional programming 2

PGM 2

2326

You can program each media key for gas discount availability and tax status (tax 1 thru 4).

Procedure
To program any media function
To program zero
2326

*1

@

.

@

Function no.

*2

ABCDE

s

a

*1: Function no.
89: For the a key
90: For the Å key
91: For the Å
3 key
92: For the Å
4 key
93: For the É key
114: For the ( key
116: For the ) key
118: For the * key

120: For the + key
122: For the , key
124: For the ,6 key
126: For the ,7 key
128: For the ,8 key
130: For the ,9 key
132: For the k key
CHK2 key
133: For the ,

*2: Item:
A
Gas discount
B

Tax 4 calculation status

C

Tax 3 calculation status

D

Tax 2 calculation status

E

Tax 1 calculation status

Note

For the /, ? and

Example

CHK3 key
134: For the ,
CHK4 key
135: For the ,
CHK5 key
136: For the ,
110: For the / key
111: For the ? key
112: For the ≥
key
3

Selection:
Disable
Enable
calculate tax 4
delete tax 4
calculate tax 3
delete tax 3
calculate tax 2
delete tax 2
calculate tax 1
delete tax 1
EAT IN
3

Entry:
0
1
0
1
0
1
0
1
0
1

keys, always enter 0 as A.

Programming the */ key to enable gas discount
Key operation

Print

2326 . @
118 @ 10000 ı

a
A thru E

142

High amount lockout (HALO) for check cashing, check change,
and cash in drawer PGM 2 2321
You can program the upper limit amounts for check cashing, check change, and cash in drawer.

Procedure
To program any function
To program zero
2321

@

.

*1

Function no.

*1: Function no.
99: For check 1 cashing
100: For check 2 cashing
101: For check 3 cashing
102: For check 4 cashing
103: For check 5 cashing
104: For check change
138: For cash in drawer (sentinel)

Example

@

*2

s

Limit amount

a

*2: Limit amount
0 thru 999999.99 (check cashing and check change)
0 thru 9999999.99 (cash in drawer)

Setting the limit to $99.99 for check 1 cashing.
Key operation

Print

2321 . @
99 @ 9999 ı

a

High amount lockout (HALO) of entry for media keys

PGM 2

2322

Direct

The HALO limit is in effect for REG mode operations but can be overridden in the MGR mode. The HALO limit
is represented by two figures as follows:

Procedure
To program any media function
To program zero
2322

.

@

*1

Function no.

@

*2

AB

s

a

*1: Function no.
89: For the a key
90: For the Å key
91: For the Å
3 key
92: For the Å
4 key
93: For the É key
114: For the ( key
116: For the ) key

118: For the * key
120: For the + key
122: For the , key
124: For the ,6 key
126: For the ,7 key
128: For the ,8 key
130: For the ,9 key

132: For the k key
CHK2 key
133: For the ,
CHK3 key
134: For the ,
CHK4 key
135: For the ,
CHK5 key
136: For the ,

*2: AB
A: Significant digit (1 thru 9)
B: Number of zeros to follow significant digit (0 thru 8)
You can set up AB = 18 for no limitation.

143

Example

Setting the HALO limit to $1000.00 (15) for the * key
Key operation

Print

2322 . @
118 @ 15 ı
HALO

a

Print station assignment

2328

PGM 2

When you use a remote printer, consult your dealer.

Procedure
To program any media function
To program zero
2328

*1

@

.

@

Function no.

*2

ABC

s

a

*1: Function no.
89: For the a key
90: For the Å key
91: For the Å
3 key
92: For the Å
4 key
93: For the É key
114: For the ( key
116: For the ) key
118: For the * key

120: For the + key
122: For the , key
124: For the ,6 key
126: For the ,7 key
128: For the ,8 key
130: For the ,9 key
132: For the k key
CHK2 key
133: For the ,

*2: Item:
A
Remote printer 1 output
B

Remote printer 2 output

C

Printing on the chit receipt

Example

CHK3 key
134: For the ,
CHK4 key
135: For the ,
CHK5 key
136: For the ,
82: For the S key
94: For the f key
238: For the ≥ key

Selection:
Output
Not output
Output
Not output
Yes
No

Programming of the * key for selecting “remote printer 1 output/remote printer 2 not
output/printing on chit receipt”
Key operation

Print

2328 . @
118 @
101 ı

a

144

Entry:
1
0
1
0
1
0

Print station

CAT programming

PGM 2

2330

When you use a credit card authorization terminal, please consult your authorized SHARP dealer.

Procedure

To program any media function
To program zero

2330

*1

@

.

@

Function no.

*2

ABCDEFGHIJK

a

s

*1: Function no.
89: For the a key
90: For the Å key
91: For the Å
3 key
92: For the Å
4 key
93: For the É key
114: For the ( key
116: For the ) key
118: For the * key

120: For the + key
122: For the , key
124: For the ,6 key
126: For the ,7 key
128: For the ,8 key
130: For the ,9 key
132: For the k key
CHK2 key
133: For the ,

*2: Item:
A
CAT transaction
B

CAT action

C

CAT type

D

Card number printing

E

Card number print format

F

CAT signature line print

G

CAT expiration printing

H
I

Always enter 0.
Tip and total amount printing on
authorization receipt
Receipt and authorization receipt
printing when the CAT entry is made
at receipt OFF status
Number of CAT authorization receipt

J

K

CHK3 key
134: For the ,
CHK4 key
135: For the ,
CHK5 key
136: For the ,
82: For the S key
238: For the ≥ key

Selection:
Entry:
Non-compulsory
Compulsory
POST-AUTH
DIAL
Authorization only
CREDIT
DEBIT
CHECK
Yes
No
Partial (printing only part of the card number)
Full (printing the entire card number)
Yes
No
Yes
No
Yes
No
Yes
No

0
1
0
1
2
0
1
2
0
1
0
1
0
1
0
1
0
0
1
0
1
0 to 9

Number of CAT authorization receipt
Even when 0 is set, 1 receipt is issued.

Example

Programming of the * key for ABCDEFGHIJK = 00000000000.
Key operation

Print

2330 . @
118 @
00000000000 ı

a

A thru K

145

8 Programming of function text
Programming

PGM 2

2314

You can program a maximum of 8 characters for each function key and other functions using the table on the
following pages. Select the characters you want to program referring to section “2 How to program alphanumeric
characters” in chapter “PRIOR TO PROGRAMMING”.

Procedure
To program any function
To keep the current setting

.

2314

@

* Function no.
(max. 3 digits)

Character keys
(max. 8 digits)

@

s

a

* Function no.: See “List of function texts” shown below (until function no. 289).

Example

Programming CARD for * key
Key operation

Print

2314 . @
118 @ CARD / / /

ı
a

List of function texts
Function
no.

146

Key or function

In default of
proramming

Function
no.

Key or function

In default of
proramming

9

%4

10

%5

(–) 1
(–) 2
(–) 3
(–) 4
(–) 5
%1
%2
%3
%4
%5

11

Gas discount for cash 1

GAS (–)1

27

Gas discount for charge 7

GAS (–)17

12

Gas discount for cash 2

GAS (–)2

28

Gas discount for charge 8

GAS (–)18

13

Gas discount for cash 3

GAS (–)3

29

Gas discount for charge 9

GAS (–)19

14

Gas discount for cash 4

GAS (–)4

30

Net sales tota

NET1

15

Gas discount for cash 5

GAS (–)5

31

Net taxable 1 subtotal

TAX1 ST

16

Gas discount for check 1

GAS (–)6

32

Gross tax 1 total

GRS TAX1

1

1

2

2

3

3

4

4

5

5

6

%1

7

%2

8

%3

17

Gas discount for check 2

GAS (–)7

18

Gas discount for check 3

GAS (–)8

19

Gas discount for check 4

GAS (–)9

20

Gas discount for check 5

GAS (–)10

21

Gas discount for charge 1

GAS (–)11

22

Gas discount for charge 2

GAS (–)12

23

Gas discount for charge 3

GAS (–)13

24

Gas discount for charge 4

GAS (–)14

25

Gas discount for charge 5

GAS (–)15

26

Gas discount for charge 6

GAS (–)16

Function
no.

Key or function

In default of
proramming

Function
no.

Key or function

In default of
proramming

33

Tax 1 total of refund entries

RFD TAX1

80

Transfer in

34

Net tax 1 total

TAX1

81

PBAL

35

Exempt tax 1

TX1 EXPT

82

Service

36

Net taxable 2 subtotal

TAX2 ST

83

Deposit

DEPOSIT

37

Gross tax 2 total

GRS TAX2

84

Deposit refund

DPST RF

38

Tax 2 total of refund entries

RFD TAX2

85

Cover count

COVER CT

39

Net tax 2 tota

TAX2

86

Customer counter

TRANS CT

40

Exempt tax 2

TX2 EXPT

87

Gratuity

GRATUITY

41

Net taxable 3 subtotal

TAX3 ST

88

Sales total

42

Gross tax 3 total

GRS TAX3

89

Cash

43

Tax 3 total of refund entries

RFD TAX3

90

Cash 2

44

Net tax 3 total

TAX3

91

Cash 3

45

Exempt tax 3

TX3 EXPT

92

Cash 4

46

Net taxable 4 subtotal

TAX4 ST

93

Cash 5

NET3
C ASH
C ASH2
C ASH3
C ASH4
C ASH5

47

Gross tax 4 total

GRS TAX4

94

Food stamp sales

FSSALE

48

Tax 4 total of refund entries

RFD TAX4

95

RA

RA

49

Net tax 4 total

TAX4

96

RA2

RA2

50

Exempt tax 4

TX4 EXPT

97

PO

PO

51

Gross manual tax total

GRS MTAX

98

PO2

52

Refund manual tax total

RFD MTAX

99

Check cashing 1

CA/CHK1

53

TRAN.IN
PBAL
SERVICE

PO2

Net manual tax total

M–TAX

100

Check cashing 2

CA/CHK2

*54

Exempt total from GST

GST EXPT

101

Check cashing 3

CA/CHK3

*55

PST total

PST TTL

102

Check cashing 4

CA/CHK4

*56

GST total

GST TTL

103

Check cashing 5

CA/CHK5

57

FS1 forgive

FS TX1

104

Check change

CHK/CG

58

FS2 forgive

FS TX2

105

Food stamp change

FS/CG

59

FS3 forgive

FS TX3

106

Currency conversion 1

CONV 1

60

Tax total

TTL TAX

107

Currency conversion 2

CONV 2

61

108

Currency conversion 3

CONV 3

62

NET
Sales total including tax total N E T 2

109

Currency conversion 4

CONV 4

63

Coupon-like PLU

CP PLU

110

Eat-in 1

EAT IN 1

64

Vender coupon UPC

V. CP UPC

111

Eat-in 2

EAT IN 2

65

Item void

VOID

112

Eat-in 3

EAT IN 3

66

Subtotal void

SBTL VD

113

Food stamp in drawer

FS/ID

67

Manager void

MGR VD

114

Gross charge 1

CHARGE1

68

Void mode

VOID

115

Refund charge 1

CHARGE1–

69

Refund

REFUND

116

Gross charge 2

CHARGE2

70

Return

RETURN

117

Refund charge 2

CHARGE2–

71

Hash item void

HASH VD

118

Gross charge 3

CHARGE3

72

Hash item refund

HASH RF

119

Refund charge 3

CHARGE3–

73

Hash item return

HASH RT

120

Gross charge 4

CHARGE4

74

No sale

NO SALE

121

Refund charge 4

CHARGE4–

75

Validation print counter

VP CNT

122

Gross charge 5

CHARGE5

76

Bill (slip) counter

BILL CNT

123

Refund charge 5

CHARGE5–

77

Drawer counter

DRW CNT

124

Gross charge 6

CHARGE6

78

Dray total counter

TRAY CNT

125

Refund charge 6

CHARGE6–

79

Transfer out

TRAN.OUT

126

Gross charge 7

CHARGE7

Net

147

Function
no.

In default of
proramming

Function
no.

Key or function

In default of
proramming

127

Refund charge 7

CHARGE7–

174

Commission sale 2

COM.SAL2

128

Gross charge 8

CHARGE8

175

Commission sale 3

COM.SAL3

129

Refund charge 8

CHARGE8–

176

Commission sale 4

COM.SAL4

130

Gross charge 9

CHARGE9

177

Commission sale 5

COM.SAL5

131

Refund charge 9

CHARGE9–

178

Commission sale 6

COM.SAL6

132

Check 1

CHECK1

179

Commission sale 7

COM.SAL7

133

Check 2

CHECK2

180

Commission sale 8

COM.SAL8

134

Check 3

CHECK3

181

Commission sale 9

COM.SAL9

135

Check 4

CHECK4

182

Non commission sale

NON COM.

136

Check 5

CHECK5

183

Commission amount 1

COM.AMT1

137

Cash + check in drawer

CA/CH ID

184

Commission amount 2

COM.AMT2

138

Cash in drawer

185

Commission amount 3

COM.AMT3

139

Cash tip

CA TIP

186

Commission amount 4

COM.AMT4

CH TIP

CID

140

Charge tip

187

Commission amount 5

COM.AMT5

141

Tip-in (used only for PGM mode) TIP IN

188

Commission amount 6

COM.AMT6

142

Tip paid

TIP PAID

189

Commission amount 7

COM.AMT7

Exempt VAT

VAT EXPT

190

Commission amount 8

COM.AMT8

144

Sales average

AVE.

191

Commission amount 9

COM.AMT9

145

Price level 1 for PLU/UPC

LEVEL 1

192

Commission amount total

COM.TTL

146

Price level 2 for PLU/UPC

LEVEL 2

193

Waste (for PLU/UPC report)

WASTE

147

Price level 3 for PLU/UPC

LEVEL 3

194

Net sales (for PLU/UPC report)

NET SLS

148

Price level 4 for PLU/UPC

LEVEL 4

195

Net sales total (for PLU/UPC report) NET TL

149

Price level 5 for PLU/UPC

LEVEL 5

196

Free GLU/PBLU (for GLU/PBLU report) FREE GLU

150

Price level 6 for PLU/UPC

LEVEL 6

197

Closed check (for server report)

CLOSE CK

151

(+) Dept. total

OPEN CK

152

(–) Dept. total

153

Hash (+) dept. total

154

Hash (–) dept. total

155

(+) Bottle return total

156

(–) Bottle return total

157

Gas (+) dept. total

*143

148

Key or function

DEPT TL
DEPT(–)
HASH TL
HASH(–)
BTTL TL
BTTL(–)
GAS TL

198

Open check (for server report)

199

Percent of net sales (for server report) (%)SALES

200

Cash/check is

CA/CH IS

201

Conversion1 is

CONV1 IS

202

Conversion2 is

CONV2 IS

203

Conversion3 is

CONV3 IS

204

CCD differ

CCD DIF.

158

Gas (–) dept. total

205

CCD differ total

DIF. TL

159

Hash net total (for trans. report) HASH TTL

206

Subtotal

SUBTOTAL

160

Waste total (for PLU/trans. report) WASTE TL

207

Merchandise subtotal

MDSE ST

161

Subtotal (–) total (for trans. report) ST(–) TL

208

Tray subtotal

TRAY TL

162

Subtotal % tota (for trans. report) ST% TL

209

Total

163

Item (–) total (for trans. report)

(–) TL

210

Change

164

Item % total (for trans. report)

% TL

211

Food stamp subtotal

FS ST

165

Gas discount total (for trans. report) GASDISTL

212

Food stamp tender

FS TEND

GAS(–)

TOTAL
CHANGE

166

RA total (for trans. report)

RA TL

213

Food stamp change

FS CG

167

PO total (for trans. report)

PO TL

214

Items

ITEMS

168

Check cashing total (for trans. report) CA/CK TL

215

Copy receipt title

DEPT

169

Cash total (for trans. report)

CASH TL

216

Group report title

GROUP

170

Check total (for trans. report)

CHECK TL

217

PLU/UPC report title

PLU/UPC

171

Charge total (for trans. report)

CHR TL

218

Stock report title

STOCK

172

Currency conversion total (for trans. report) CONV TL

219

Zero sales report title

ZERO SAL

173

Commission sale 1

220

Category report title

CATEGORY

COM.SAL1

Function
no.

Key or function

In default of
proramming

Function
no.

Key or function

In default of
proramming

221

Transaction report title

TRANS.

222

Cash in drawer report title

CID

223

Commission sales report title SALES

224

CCD report title

CCD

259

Gas sales subtotal (for charge 3) GAS13 ST

225

Server/cashier report title

SERVER

260

Gas sales subtotal (for charge 4) GAS14 ST

226

Hourly report title

HOURLY

261

Gas sales subtotal (for charge 5) GAS15 ST

227

Daily net report title

DAILY

262

Gas sales subtotal (for charge 6) GAS16 ST

228

GLU/PBLU report title

GLU

263

Gas sales subtotal (for charge 7) GAS17 ST

229

Non-accessed UPC report title NO ACCES

264

Gas sales subtotal (for charge 8) GAS18 ST

230

Dynamic UPC report title

DYN.UPC

265

Gas sales subtotal (for charge 9) GAS19 ST

231

Tax report title

TAX

266

AMOUNT (text on display)

AMOUNT

232

Non-add code text

267

WEIGHT (text on display)

WEIGHT
RF SALE

#

256

Gas sales subtotal (for check 5)

GAS10 ST

257

Gas sales subtotal (for charge 1) GAS11 ST

258

Gas sales subtotal (for charge 2) GAS12 ST

233

GLU/PBLU code text

Refund type of sales (text on display)

Copy receipt title

TBL#
COPY

268

234

269

Price change title

PR. CHNG

235

Waste receipt title

WASTE

270

Tip amount for tip edit

TIP AMT

236

Bill transfer receipt title

Final balance (for closed GLU report)

FIN. BAL

Bill separate receipt title

B. T.
B. S.

271

237

272

Edit tip

EDIT TIP

BILL

238

Final (used only for PGM mode)

FINAL

273

Bill on receipt title

239

Balance

BALANCE

274

RA cash total (for trans. report) RA CASH

240

Slip print message on journal SLIP PR.

275

RA2 cash total (for trans. report) RA2 CASH

241

Slip next page

NEXT P.

276

RA check total (for trans. report) RA CHK

242

Balance forward

BAL FWD

277

RA2 check total (for trans. report) RA2 CHK

243

Tare weight

TARE WT.

278

RA charge total (for trans. report) RA CHR

244

DUE (text on display)

DUE

279

RA2 charge total (for trans. report) RA2 CHR

245

Tip due (text on display)

TIP DUE

280

RA food stamp total (for trans. report)

246

TAX ST (text on display)

TAX ST

281

RA2 food stamp total (for trans. report) RA2 FS

247

Gas sales subtotal (for cash 1)

GAS1 ST

282

PO cash total (for trans. report) PO CASH

RA FS

248

Gas sales subtotal (for cash 2)

GAS2 ST

283

PO2 cash total (for trans. report)

PO2 CASH

249

Gas sales subtotal (for cash 3)

GAS3 ST

284

PO check total (for trans. report)

PO CHK

250

Gas sales subtotal (for cash 4)

GAS4 ST

285

PO2 check total (for trans. report) PO2 CHK

251

Gas sales subtotal (for cash 5)

GAS5 ST

286

PO charge total (for trans. report) PO CHR

252

Gas sales subtotal (for check 1)

GAS6 ST

287

PO2 charge total (for trans. report) PO2 CHR

253

Gas sales subtotal (for check 2)

GAS7 ST

288

PO food stamp total (for trans. report) PO FS

254

Gas sales subtotal (for check 3)

GAS8 ST

289

PO2 food stamp total (for trans. report) PO2 FS

255

Gas sales subtotal (for check 4)

GAS9 ST

Note

• The items marked with “ * ” are for Canada only.
• The function no. 143 “Exempt VAT” is only effective for the Canadian tax system (2 GST, VAT
type).

149

9 Server/Cashier programming
The ER-A520 provides a cashier system and the ER-A530 provides a server system.
Please note that texts for cashiers/servers are printed as servers (SRV/SERV) on the receipts.

Server/Cashier code

PGM 1

PGM 2

1400

You can assign a server/cashier code to each server/cashier. For more details, please contact your authorized
SHARP dealer.

Procedure
To program any cashier no.
To program zero
1400

.

Server/Cashier no.
(1 - 20)

@

* Code
(1 - 9999)

@

a

s

* Programming code “0” inhibits entries of the selected server/cashier no.

Example

To program 1111 for server/cashier no.1 and 1014 for server/cashier no. 4
Key operation

Print

1400 . @
1 @ 1111 ı
4 @ 1014 ı

Server/
Cashier
code

a

Server/Cashier name

PGM 1

PGM 2

1414

You can program a maximum of 8 characters (server/cashier name) for each server/cashier. Select the
characters you want to program referring to section “2 How to program alphanumeric characters” in chapter
“PRIOR TO PROGRAMMING”.

Procedure
To program any server/cashier code
To keep the current setting
1414

Note

.

@

Server/Cashier code
(1 - 9999)

@

Character keys
(max. 8 digits)

s

The server/cashier code must be programmed for the server/cashier by job #1400 prior to assigning
text.

Example

To program “DICK” for server/cashier code 1111 and “PETER” for server/cashier code 1014
Key operation

Print

1414 . @
1111 @ DICK ı
1014 @ PETER ı

a
Server/Cashier name

150

a

Functional programming

2410

PGM 2

Procedure
To program any server/cashier code
To program zero
2410

Note

Server/cashier code
(1 - 9999)

@

.

* AB

s

a

The server/cashier code must be programmed for the server/cashier by job #1400 prior to the
programming.

* Item:
A
GLU/PBLU/Manual PB/CB entry
B

@

Drawer no.

Example

Selection:
Non-compulsory
Compulsory
Use no drawer
Set the drawer no. 1 or 2

Entry:
0
1
0
1 or 2

Programming AB=01 for server/cashier code 1111
Key operation

Print

2410 . @
1111 @ 01 ı

a

GLU/PBLU code range assignment

PGM 2

2411

Procedure
2411

.

@
To program zero (no assignment)
To assign start code only

Server/cashier
code (1 - 9999)

Note

@

GLU/PBLU start
code (1 - 9999)

@

GLU/PBLU end
code (1 - 9999)

s

a

The server/cashier code must be programmed for the server/cashier by job #1400 prior to the
programming.

Example

Assigning GLU/PBLU code 1 to 100 for server/cashier code 1111
Key operation

Print

2411 . @
1111 @ 1 @ 100 ı

a
GLU/PBLU range

151

Net sales % rate

PGM 2

2413

Procedure
To program any server/cashier code
To program zero
2413

Note

.

@

Server/cashier code
(1 - 9999)

@

Net sale % rate
(0.00 to 100.00)

s

a

• You must enter the decimal for fractional rates.
• The server/cashier code must be programmed for the server/cashier by job #1400 prior to the
programming.

Example

Programming 20% for server/cashier code 1111
Key operation

Print

2413 . @
1111 @ 20 ı

a

10 Programming various functions
Programming for optional feature selection

PGM 2

2616

Your register enables you to select the following options:
OP X/Z mode availability
When a cashier needs to take the cashier X/Z report, he or she will use the OP X/Z mode.
This programming determines whether he or she will be allowed to use this mode.

Note

You can take the cashier X and Z reports in the X1/Z1 mode regardless of the above programming.

Paid-out in the REG mode
Refund type of sale in the REG mode
Refund in the REG mode
Direct void in the REG mode
Indirect void in the REG mode
Subtotal void in the REG mode
Validation printing in a refund/return entry
First item direct void
PLU level shift mode
• Automatic return mode: This mode automatically shift the PLU level back to level 1 (ordinary level) after a
direct PLU entry.
• Lock shift mode:
This mode holds the current PLU level until making a level shift operation
(pressing a level shift key).

152

Available mode for PLU level shift
Printing of the number of purchased items
Time printing on the receipt/journal
Journal print form
You may choose either of the following forms.
• Detailed journal print that shows the details of all entries – the same information as printed on the receipt.
• Summary journal print that shows information about all entries other than normal department entries
(entries into “+” departments and their associated “+” PLUs).
Availability of the item validation printing
Validation printing in a discount (â) entry
Zero skip for various reports
Share % printing in dept. report
Tip entry method
Cover count entry
Automatic return mode for PLU level
• By one receipt: Returns the PLU level to level 1 after each receipt.
• By one item:
Returns the PLU level to level 1 after each item entry.
Available mode for PLU/UPC price shift
PLU/UPC price shift mode
• Automatic return mode: This mode automatically shifts the price level back to price 1 (ordinary level) after
the entry.
• Lock shift mode:
This mode holds the current price level until making a price shift selection
(pressing the price shift key).
Automatic return mode for PLU/UPC price level
• By one receipt: Returns the price level to price 1 after each receipt.
• By one item:
Returns the price level to price 1 after each item entry.
No sale in REG mode
Void mode in REG mode
Finalization when the subtotal amount is zero in the REG mode
Item printing in PBLU transactions on the slip
Tip-paid operation in REG mode
Transfer-in/out operation in REG mode
Usability of the RA entry
Validation printing in a check cashing entry
Validation printing in a RA entry
Validation printing in a PO entry
Birthday date printing for the age limitation
Footer graphic logo printing
Learning function of UPC entry
Price change function in REG mode
Printing of the price shift text on the receipt/journal
Treating the EAN8 code (200XXXXC/D)
Price entry after ISBN/ISSN code entry

153

Procedure
To program any function no. (**P: 1-13)
To program zero
2616

.

@

** P
(1 - 13)

@

**P: 1
* Item:
A OP X/Z mode
B

Paid-out in REG mode

C

Refund type of sale in the REG mode

D

Refund and return in the REG mode

E

Direct void in REG mode

F

Indirect void in the REG mode

G Subtotal void in REG mode
H

Validation printing in a refund and return entry

**P: 2
* Item:
A The first item direct void
B

PLU level shift mode

C

Available mode for PLU level shift

D

Printing of the number of purchased items

E

Time printing on the receipt/journal

F

Journal print form

G Availability of the item validation printing
H

154

Validation printing in a discount (â) entry

*ABCDEFGH

s

a

Selection:
Enable
Disable
Enable
Disable
Enable
Disable
Enable
Disable
Enable
Disable
Enable
Disable
Enable
Disable
Non-compulsory
Compulsory

Entry:
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1

Selection:
Enable
Disable
Automatic return mode
Lock shift mode
REG and MGR modes
MGR mode only
No
Yes
Yes
No
Detailed
Limited
Enable
Disable
Non-compulsory
Compulsory

Entry:
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1

**P: 3
* Item:
A Always enter 0.
B Always enter 0.
C Zero skip in server/cashier report
D

Zero skip in transaction report

E

Zero skip in department report

F

Zero skip in PLU/UPC report

G Zero skip in hourly report
H

Zero skip in daily net report

**P: 4
* Item:
A Share % printing in dept. report
B

Tip entry method

C
D
E
F

Always enter 0.
Always enter 0.
Always enter 0.
Cover count entry

G Always enter 0.
H Automatic return mode for PLU level shift

Note

G PLU/UPC price shift mode
Automatic return mode for PLU/UPC price level

Note

Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No

Selection:
Yes
No
Amount entry
Fixed rate entry

Non-compulsory
Compulsory
After each item
After each receipt

Entry:
0
0
0
1
0
1
0
1
0
1
0
1
0
1

Entry:
0
1
0
1
0
0
0
0
1
0
0
1

Automatic return mode for PLU level shift: This setting is available only when available mode for
PLU level shift is set to automatic return mode. (See P:2/parameter B shown above.)

**P: 5
* Item:
A Always enter 0.
B Always enter 0.
C Always enter 0.
D Always enter 0.
E Always enter 0.
F Available mode for PLU/UPC price shift

H

Selection:

Selection:

REG and MGR modes
MGR mode only
Automatic return mode
Lock shift mode
After each item
After each receipt

Entry:
0
0
0
0
0
0
1
0
1
0
1

Automatic return mode for PLU/UPC price level: This setting is available only when PLU/UPC price
shift mode is set to automatic return mode (parameter G).

**P: 6 (ABCDEFGH: Always enter 0.)

155

**P: 7
* Item:
A Void mode in REG mode
B
C

Always enter 0.
No sale in REG mode

D

Finalization when the subtotal amount is zero
in the REG mode
Item printing in GLU/PBLU transaction
on the slip
Tip-paid operation in REG mode

E
F

G Transfer-in/out operation in REG mode
H

Enable
Disable
Enable
Disable
Yes
No
Enable
Disable
Enable
Disable

Always enter 0.

**P: 8
* Item:
A Always enter 0.
B Always enter 0.
C Always enter 0.
D Usability of the received-account entry
E

Validation printing in a check cashing

F

Validation printing in a received-account entry

G Validation printing in a paid-out entry
H

Selection:
Enable
Disable

Validation printing in tip-in/tip-paid operation

Entry:
0
1
0
0
1
0
1
0
1
0
1
0
1
0

Selection:

Entry:
0
0
0
Without limitation
0
Only for GLU/PBLU transaction
1
Non-compulsorly
0
Compulsory
1
Non-compulsorly
0
Compulsory
1
Non-compulsorly
0
Compulsory
1
Non-compulsorly
0
Compulsory
1

**P: 9

*

Item:
A Always enter 0.
B Always enter 0.
C Birthday date printing for the age limitation
D
E
F
G
H

Always enter 0.
Always enter 0.
Always enter 0.
Always enter 0.
Footer graphic logo printing

Selection:

Yes
No

No
Yes

Entry:
0
0
0
1
0
0
0
0
0
1

**P: 10
*

Item:
A and B Always enter 0.
C
Learning function of UPC entry
D to H

156

Always enter 0.

Selection:
Yes
No
(Fixed position)

Entry:
0
0
1
0

**P: 11 (ABCDEFGH: Always enter 0.)
**P: 12
*

Item:
A to G
H

Selection:
Always enter 0.
Price change function in REG mode

Entry:
0
0
1

Enable
Disable

**P: 13
*

Item:
A to C
D

Selection:

E
F

Always enter 0.
Printing of the price shift text on the
receipt/journal
Always enter 0.
Treating the EAN8 code (200XXXXC/D)

G
H

Always enter 0.
Price entry after ISBN/ISSN code entry

Example

Entry:
0
0
1
0
0
1
0
0
1

Yes
No
Yes
No
Compulsory
Inhibited

Programming to select zero suppression for the server/cashier report, transaction report,
dept. report, PLU/UPC report and daily net report, and to select non-skip printing for an hourly
report.
Key operation

Print

2616 . @
3 @ 00000010 ı

P: 1 thru 13

a
A thru H

Programming the parameter of the slip printer

PGM 2

2615

Procedure
When A thru F are zeroes
2615

.

@

*ABCDEF

a

* AB: Initial slip feed line (0 to 64)
CD: Slip print max. line no. (0 to 99)
E: Validation printing counter (1 thru 9 times)
To inhibit validation printing, enter 0.
F: Feed lines after printing of a tray subtotal (0 thru 9 lines)

Example

Entering 009910 to ABCDEF
Key operation

Print

2615 . @
009910 a
157

Setting the time limit for THE TILL TIMERTM

PGM 2

2617

The machine counts the number of times the drawer is left open for longer than a programmed time limit. The
counter will be incremented by one each time a programmed time limit is reached. The time limit for THE TILL
TIMERTM can be preset for 0 to 255 seconds. The count is printed on the general report and cashier report.

Procedure
To program 0
2617

.

Example

a

Time limit
1 to 255 seconds

@

Setting the time limit as 30 (seconds).
Key operation

Print

2617 . @
30 a

Scale tare table

PGM 2

2618

The register can be programmed with up to nine tare tables and allows different tares to be assigned to them
(for auto scale entries).

Procedure
To program 0
2618

.

@

@

Table no.
(1 to 9)

Tare weight
(0.01 to 99.99)

s

a

To program any tare table no.

Example

To assign the tare weight 0.20 lbs to tare table no. 1
Key operation

Print

2618 . @
1 @ 20 ı

a

158

Table no.
Tare weight

Programming of logo messages

2614

PGM 2

Your register can print programmed messages for customers on every receipt. On the standard model, the
ER-A520 prints a graphic logo/the ER-A530 is set to print a header 3-line message on the receipt. (If you want a
graphic logo customerized for your store, please consult your dealer.)
If you want to print logo message, please consult your dealer too. You have five options described below.
Select the characters you want to program, referring to section “2 How to program alphanumeric characters” in
chapter “PRIOR TO PROGRAMMING.”

Procedure
To program any line no.
To keep the current setting
2614

.

@

*Line number
(1 to 6)

@

Character keys
(max. 30 digits)

s

a

* “Header 3-line message” type: 1 to 3
“Footer 3-line message” type : 4 to 6
“Header 6-line message” type: 1 to 6
“Header 3-line and footer 3-line message” type: 1 to 6 (1 to 3 as header, 4 to 6 as footer)
Text 1st line
Graphic logo

Graphic logo

Text 2nd line

Graphic logo

Text 3rd line

Text 1st line

Text 1st line

Text 2nd line

Text 2nd line

Text 3rd line

Text 3rd line

Text 1st line

Text 4th line

Text 2nd line

Text 5th line

Text 3rd line

Text 6th line

Text 4th line

Text 4th line

Text 5th line

Text 5th line

Text 6th line

Graphic logo only

Example

Header 3-line message

Footer 3-line
message

Text 6th line

Header 6-line
message

Header 3-line
message and
footer 3-line
messages

To program the following logo message by using 3 lines:
YOUR
STORE
MESSAGE
Key operation

Print

2614 . @
1@//////////
ÎYOURÎ

///////t
2@/////////
ÎSTOREÎ

//////t
3@///////
ÎMESSAGEÎ

///t
Ç
(/:Space key)
159

Selection of X1/Z1 and X2/Z2 reports to be printed in the stacked report
sequence PGM 2 2620
Your register is equipped with the stacked report printing function that enables multiple X/Z reports to be printed
in sequence with only a single request.

Procedure
To cancel the stacked report sequence

@

.

2620

For full reporting (non-range report)
*2

@

*1
Job no.

@

Start range
parameter

For individual reporting
* 2 End range
parameter

s

a

To program any Job no.

Note

• A maximum of 70 steps are programmable. “1 step” means the memory size used for one norange type job no. The range type reports needs 6, 8 or 16 steps to execute the printing. Find
how many steps are required at the column of Note to calculate total number of steps for the
reports you want to print in sequence.
• When the Z of stacked report is initiated, X only reports will be skipped.

Job code numbers to be used are as follows.
*1: Job no.

Report name

Note

*2: Start/End range parameter

00

General

10

Full department

13

Full department group

20

PLU/UPC

*3 Start code/End code (max. 5/13 digits)

16 steps

24

PLU/UPC stock

*3 Start code/End code (max. 5/13 digits)

16 steps

27

PLU/UPC zero sales

29

PLU/UPC price category

*3 Start price amount/End price amount

8 steps

30

Transaction

31

Cash in drawer

32

Commission sale

33

Tax

40

Full server/cashier

60

Hourly sales information

*3 Start time/End time (0 thru 2330)

Range report is available
only in the X1 mode.
6 steps for a range report.

69

Dynamic UPC

*3 Start code/End code (max. 13 digits)

16 steps

70

Daily net report

80

GLU/PBLU report

*3 Start GLU/PBLU code/End GLU/PBLU code
(1 thru 9999)

6 steps

*3: Both range setting and full setting are allowed.

Example

To print reports 10 and 13 as a stacked report.
Key operation

Print

2620 . @
10 ı
13 ı
160

a

Setting the time range for hourly reports

PGM 2

2619

You can set the time range for the hourly report.

Procedure
2619

.

When A thru C are all zeros.

@

*ABC

a

*A: Time range
To set the time range to 30 minutes (in the 24-hour system), enter 0.
To set the time range to 60 minutes (in the 24-hour system), enter 1.
BC: Starting time (hour = 00 to 23)

Example

Setting the time range to 60 minutes with the starting time being set at 7:00
Key operation

Print

2619 . @
107 a

Note

To change this setting, an hourly Z report (#160) must be taken prior to the changes.

Programming of power save mode

PGM 2

2689

Procedure
2689

*

.

@

*A B C D

a

Item:
A
Entering power save mode when time is
displayed.
BCD Time (min.) to entering power save mode
since no operation is made.

Example

Key operation

Selection:
Enable
Disable

Entry:
0
1
1 through 254 (min.)
(999: The power save mode is inhibited.)

Print

2689 . @
0030 a

161

Available GLU/PBLU codes

PGM 2

2810

You can specify the range of GLU/PBLU codes available for the register.

Procedure
To program only one code
2810

@

.

Example

Start code
(1 - 9999)

@

End code
(1 - 9999)

a

Programming 1 for start code and 1000 for end code
Key operation

Print

2810 . @
1@
1000 a

Bill number

PGM 2

2636

A consecutive bill number is automatically increased by one each time a GLU/PBLU entry is finalized.
Specify a number that one less than a desired starting number.

Procedure
To program zero
2636

.

Example

@

Bill number
(0-9999)

Starting bill number from 1
Key operation

2636 . @
0Ç

162

Ç
Print

Functional programming for the printer

PGM 2

2990

You can program the printing density of the receipt/journal printer.

Procedure
To program zero
2990

.

@

*AB

Ç

*AB: Printing density (00 – 99)
00 = 89% for standard density
50 = 100% for standard density
99 = 111% for standard density

Example

Programming “100% for standard density”
Key operation

Print

2990 . @
50 Ç

Editing guidance/error messages

PGM 2

2641

Your register has standard guidance/error messages as indicated in the following list. For more information
about the alphanumeric characters programming, see section “2 How to program alphanumeric characters”
under the chapter “PRIOR TO PROGRAMMING”.

Procedure
To program any text no. (1 - 94)
To keep the current setting
2641

.

@

@

* Text no.
(1 - 94)

Character keys
(max. 12 digits)

t

Ç

* Text no.: See “LIST OF GUIDANCE/ERROR MESSAGES” shown on the following page.

Example

Programming “ENTRY ERROR” for text no. 1
Key operation

Print

2641 . @
1@
ENTRY / ERROR t

Ç

163

LIST OF GUIDANCE/ERROR MESSAGES
Text
no.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17-19
20
21
22
23-26
27
28-29
30
31
32
33
34
35
36
37
38

164

Description
Registration error
Misoperation error
Desired code is not
programmed yet.
(Reserved)
Secret code error
Code is not free
Memory is full.
Insert slip paper.
The entered server/cashier’s code
is not authorized.
Stock is empty.
Compulsory pushing
the subtotal key
Compulsory tendering
Compulsory GLU/PBLU entry
(Reserved)
Compulsory cover count entry
Check edit error
(for manual PB entry)
(Reserved)
Remote printer off line
(Reserved)
Overlapped server/cashier error
(Reserved)
Power off
(Reserved)
Compulsory tender entry for tip
Compulsory non-add code
The server/cashier is not assigned.
(Reserved)
Overflow limitation
The open price entry is
inhibited.
The unit price entry is
inhibited.
The direct non-tendering
finalization after previous
tender entry is inhibited.
Read error of scale data

In default of
programming
ENTRY ERROR
MISOPERATION

SECRET CODE
NOT FREE
MEMORY FULL
INSERT SLIP

Text
no.
39-47
48
49
50
51
52
53
54
55-60

NO AUTHORITY

61

OUT OF STOCK

62
63
64
65-66
67
68-69
70
71
72-73
74
75

NO RECORD

SBTL COMPUL.
TEND COMPUL.
PB COMPUL.
COV CNT COMP
C/D ERROR
OFF LINE
SERVER ERR.

76

POWER OFF

77
78

TIP ERROR
# COMPULSORY
NOT ASSIGNED

79
80
81

INH. OPEN PR

82-83
84
85

INH. UNIT PR

86

OVER LIMIT.

NOT NON-TEND
SCALE ERROR

87
88
89-93
94

Description
(Reserved)
Enter check number
Enter cover count
(Reserved)
Weight on scale
Closed check file is full.
(Reserved)
Entry of tare weight
(Reserved)
Desired code is not programmed
yet. (learning function)
Enter price and dept. no.
Enter price and dept. no.
Enter dept. no.
(Reserved)
REG buffer is full.
(Reserved)
Price entry at UPC refund
PLU/UPC file is full.
(Reserved)
Non-accessed UPC delete job
(Reserved)
Closing the drawer is
compulsory.
Price level shift error
(Reserved)
Reading of undefined vender
coupon UPC
(Reserved)
Message for prompting entry
of secret code
(Reserved)
Data backup send success
Data backup receive success
Data backup communication
error
Backup data format error
Data backup time out error
(Reserved)
Age limitation error

In default of
programming
ENTER CHECK#
COVER COUNT
WEIGHT
C.FILE FULL
ENTR TARE WT
NO RECORD
PRICE → DEPT
PRICE & DEPT
ENTER DEPT#
BUFFER FULL
ENTER PRICE
UPC FULL
DELETE
CLOSE DRAWER
ENTER P.SFT
OP ENTER

ENTR SECRET#
SEND OK
RECEIVE OK
COM. ERROR
DATA ERROR
TIME OUT
AGE ERROR

Validation message

PGM 2

2642

You can program the text (3 lines) to be printed on validation slip. Up to 30 characters can be programmed per
line.

Procedure
To program any line no.
To keep the current setting
2642

.

Example

@

@

Line no.
(1 - 3)

Character keys
(max. 30 digits)

t

Ç

Programming “FOR DEPOSIT ONLY” for the check validation message
Key operation

Print

2642 . @
3@
FOR / DEPOSIT / ONLY t

Ç
Note

The ∏ key must be placed on the keyboard.

Slip printer’s logo message

PGM 2

2643

You can program the text (3 lines) to be printed on slip. Up to 30 characters can be programmed per line.

Procedure
To program any line no.
To keep the current setting
2643

.

Example

@

@

Line no.
(1 - 3)

Character keys
(max. 30 digits)

t

Ç

Programming “TEXT1” for the slip printer’s logo message
Key operation

Print

2643 . @
1@
TEXT1 t

Ç
Note

The Ω key must be placed on the keyboard.

165

RS-232C channel assignment

PGM 2

2690

Your register is equipped with two RS-232C interfaces. If you use the communication functions, the channel
number of each RS-232C interface must be programmed by using the following procedure.
To activate the communication functions, please consult your dealer.

Procedure

To program any function no. (**P: 1 - 3)
To program zero

2690

.

@

** P
(1 - 3)

@

*ABCD

t

Ç

** P: 1
* Item:
A
Channel no. for the ON-LINE communication

B

Channel no. for print data sending (CVM)

C

Channel no. for the scale

D

Channel no. for the coin dispenser

Selection:
Not connected
Standard channel 1
Standard channel 2
Not connected
Standard channel 1
Standard channel 2
Not connected
Standard channel 1
Standard channel 2
Not connected
Standard channel 1
Standard channel 2

Entry:
0
1
2
0
1
2
0
1
2
0
1
2

Selection:
Not connected
Standard channel 1
Standard channel 2
Not connected
Standard channel 1
Standard channel 2
Not connected
Standard channel 1
Standard channel 2

Entry:
0
1
2
0
1
2
0
1
2
0

** P: 2
* Item:
A
Channel no. for the barcode reader

B

Channel no. for the remote printer 1

C

Channel no. for the remote printer 2

D

Always enter 0.

Note

For the barcode reader, when you use the model ER-A6HS1, always select the standard channel 1.

** P: 3
* Item:
A
Always enter 0.
B
Channel no. for the slip printer TM-295
(see below for the selection)
C
D

Always enter 0.
Channel no. for CAT

Selection:
Not connected
Standard channel 1
Standard channel 2
Not connected
Standard channel 1
Standard channel 2

Channel no. for the slip printer TM-295
Select “Not connected” for internal printer (printing bills on receipt)
Set “standard channel 1” or “standard channel 2” for TM-295 printer.

166

Note

• Never enter any number other than 0, 1 and 2.
• The data backup function always uses standard channel 1.

Entry:
0
0
1
2
0
0
1
2

Example

Assigning channel 1 to the slip printer TM-295
Key operation

3

Print

2690 . @
@ 0100 t

Ç

Barcode reader programming

PGM 2

2691

Procedure
To program zero
2691

.

@

*ABCD

* Item:
A
Data bit
B

Parity bit

C

Stop bit

D

Transmission speed

Ç
Selection:
7 bits
8 bits
Non parity
Odd parity
Even parity
1 bit
2 bits
19200 bps
9600 bps
4800 bps

Entry:
1
0
2
1
0
1
0
2
1
0

Example
Key operation

Print

2691 . @
1110 Ç
ABCD

167

Remote printer assignment

PGM 2

2692

Procedure
To program zero
2692

.

@

Remote printer no.
(1 or 2)

* Item:
A
Logo text printing
B

Auto cutter function

C

Type of the printer

@

Ç

t

*ABC

Selection:
Not print
Print
Disable
Enable
TM-U200 or TM-U230
TM-U220 (type B only)
TM-T88(3)
TM-T88(3)+Logo

Entry:
0
1
0
1
0
1
2
3

Example
Key operation

Print

2692 . @
1 @ 100 t

Ç

Second remote printer assignment

PGM 2

3653

Procedure
To program zero
3653

.

@

Remote printer no.
(1 or 2)

* Item:
A
Second remote printer

@

*A

Ç

t

Selection:
Nothing
Remote printer 1
Remote printer 2

Entry:
0
1
2

Example
Key operation

Print

3653 . @
1@2t

Ç
Remote printer 2

168

Remote printer name

PGM 2

3654

Procedure
To keep current setting
3654

.

@

Remote printer no.
(1 or 2)

@

Printer name
(max. 12 characters)

Ç

t

Example
Key operation

Print

3654 . @
1 @ KP1 t

Ç
Printer name

Print format for remote printer

3655

PGM 2

Procedure
To program zero
3655

.

@

Remote printer no.
(1 or 2)

* Item:
A
Taxable status print
B

Q’ty print when q’ty is “1”.

C

Dept./PLU/UPC code print

D

Unit price print

E

Amount print

@

t

*ABCDE

Selection:
Not print
Print
Not print
Print
Not print
Print
Not print
Print
Not print
Print

Ç
Entry:
0
1
0
1
0
1
0
1
0
1

Taxable status print
Taxable status printing is allowed only when “amount print” (parameter E) is set to “Print”.

Example
Key operation

Print

3655 . @
1 @ 00000 t

Ç

Print format

169

Chit receipt format

PGM 2

3656

Procedure
To program zeros
3656

.

@

*ABCDE

* Item:
A
Taxable status print
B

Q’ty print when q’ty is “1”.

C

Dept./PLU/UPC code print

D

Unit price print

E

Amount print

Ç
Selection:
Not print
Print
Not print
Print
Not print
Print
Not print
Print
Not print
Print

Entry:
0
1
0
1
0
1
0
1
0
1

Taxable status print
Taxable status printing is allowed only when “amount print” (parameter E) is set to “Print”.

Example
Key operation

3656 . @
00000 Ç

170

Print

RS-232C interface

6110

PGM 2

6111

6112

6113

6115

6212

6213

6220

Online terminal number
Procedure
To program zero

.

6110

@

Ç

Terminal no.
(max. 6 digits)

Transmission line form system
Procedure
To program zero

.

6111

@

Ç

*AB

* Item:
A
Sending of the CI signal
B

Line form

Selection:
No
Sending
Full duplex system
Half duplex system

Entry:
0
1
0
1

Selection:
4800 bps
9600 bps
19200 bps
38400 bps

Entry:
4
5
6
7

Functional programming
Procedure

.

6112

@

*A

Ç

* Item:
A
Baud rate (38400/19200/9600/4800 bps)
The selected baud rate is used for on-line
communications.
It is not used for the data backup function.

Start code and end code
Procedure
To program zero
6113

.

@

*ABCDEF

Ç

* ABC: Start code (000 – 127)
DEF: End code (000 – 127)

Time out setting
Procedure
6115

.

@

Time out time
(1 – 255 sec)

Ç

171

Baud rate specification for print data sending
Procedure

.

6212

* Baud rate
4: 4800 bps

@

5: 9600 bps

Ç

* Baud rate

6: 19200 bps

7: 38400 bps

Start/end code specification for print data sending
Procedure
To program zero

.

6213

@

Ç

*ABCDEF

* ABC: Start code - 000 to 127
DEF: End code - 000 to 127

Functional selection for print data sending
Procedure
To program zero
6220

.

@

* Item:
A
Sensing of DR signal

172

B

Sensing of CS signal

C

Sending of all print data

*ABC

Ç
Selection:
Yes
No
Yes
No
Disable
Enable

Entry:
0
1
0
1
0
1

Programming the CAT interface

7110

PGM 2

7111

7112

7113

7114

7115

7116

Phone number for dial out
Procedure
To keep the current setting

.

7110

@

Ç

* Character keys
(max. 25 digits)

* The valid characters for dialing are “0 – 9”, “W” and “,”.

Password for dial out
Procedure
To program zero

.

7111

@

* Password
(max. 8 digits)

Ç

* The password can be programmed with zero suppression, however it is
used without zero suppression (00000000 - 99999999) for dialing.

Functional selection
Procedure
To program zero

.

7112

@

*ABCD

Ç

* Item:
A
Food stamp mode
B

PIN PAD on CAT for DEBIT CARD

C

Key type for PIN PAD

D

Dial mode for dial out

Selection:
Disable
Enable
Yes
No
STATIC
DUKPT
INDEX
Tone
Pulse

Entry:
0
1
0
1
0
1
2
0
1

Time out setting for time 1 (reading a credit/debit card)
Procedure
7113

.

@

Time out time
(1 – 255 sec)

Ç

173

Time out setting for time 2 (for the response of authorization)
Procedure
7114

.

@

Time out time
(1 – 255 sec)

Ç

Time out setting for time 3 (for the reading of dial in/out)
Procedure
7115

.

@

Time out time
(1 – 3000 sec)

Ç

Allowed cash tip rate for authorization
Procedure
To program zero
7116

.

@

*Rate
(0.00 - 100.00)

Ç

* You need a decimal point for fractional rate entry.

174

Secret codes to control access to the PGM1 mode, X1/Z1 mode and X2/Z2
2631
2632
mode PGM 2 2630
When a secret code has been set for that specific mode operation, before performing any PGM1 mode, X1/Z1
mode or X2/Z2 mode operation, you must enter a secret code according to the following procedure.
Operating

Procedure

Ç
Note

Ç

Secret code
(max. 4 digits)

• Once a secret code is entered, it does not need to be entered again unless the mode switch
setting is changed or an operation is performed.
• In case a secret code is forgotten, enter zero to cancel a secret code entry.

Programming

Procedure
*
2630
2631
2632

To program zero (no code)

.

@

Secret code
(max. 4 digits)

Ç

* 2630 for the PGM1 mode
2631 for the X1/Z1 mode
2632 for the X2/Z2 mode

Example

Programming secret code 1234 for X1/Z1 mode
Key operation

Print

2631 . @
1234 Ç

Loading dynamic UPCs to the main UPC file

PGM 2

2099

The UPC master file can be updated by loading the data recorded in the dynamic UPC file to the UPC master
file. Execute the following job.

Procedure
2099

.

@

Ç

175

Setting the AUTO key — Automatic sequencing key —

X2/Z2

2900

If you program frequently performed transactions or report sequences for the AUTO keys, you can enter those
transactions simply by pressing the corresponding AUTO keys during key operations. This programming can be
done when your machine is in the X2/Z2 mode.

Procedure

.

2900

@
Delete

` (ˇ) ˇ
thru

10

Transaction

` (ˇ) ˇ
thru

10

Ç

max. 50 times

Example

Programming for the ` key and ¡ key as follows:
`; entering a $1.50 item (PLU2) and a $1.00 item (dept. 3)
¡; selling a $5.00 -programmed- item (dept. 2) for cash
Key operation

Print

2900 . @
AUTO1
setting

AUTO2
setting

Note

176

`
˘ 100 3
`
¡
2Ç
¡
Ç

• When the AUTO key has been programmed to execute a report job function etc., the mode switch
must be in the corresponding position.
• The AUTO sequence key can not be preset to another AUTO sequence key.

11 TRAINING mode
The training mode is used when the operator or the manager practices register operations.
When a training cashier has been selected, the machine automatically enters the training mode. When a
training cashier has not been selected, the register automatically enters the ordinary REG mode. (For
programming of a training cashier, please consult your local dealer.)
The training operations are valid only in REG, MGR, and VOID mode.
The training cashier memory is updated in the training mode. Other memories are not updated.

Example

Key operation

Print

1000 2
3@3

Ç

177

12 Reading stored programs
Your machine allows you to read program stored in the PGM1 and PGM2 modes.

Program details and procedures for their reading
Program for:

Mode
switch
position

Job
code no.

@

1100
1

Departments

PGM2 or
PGM1

Related job
code nos.

Procedure

For reading all codes

1100

For individual reading
Start
dept. code

@

End
dept. code

Ç

@

1200

For reading all codes
For individual reading
Start PLU/
UPC code
2

PLUs/UPCs

PGM2 or
PGM1

1200

1110, 2110,
2111, 2112,
2114, 2115,
2116, 2180,
2118, 2158

@

End PLU/
UPC code

For the last picking list
Scan UPC code

Ç

MDSE
SBTL

Ä
MDSE
SBTL

PLU/UPC code

1200, 1210,
1211, 2210,
2211, 2217,
2214, 2215,
2222, 2230,
2231, 2232,
2235, 2236,
2280, 2218,
2216, 2234,
2244, 2258

To pick up PLU/UPC codes
3

4

Key nos. for
departments and
PLUs

Link PLUs/UPC
link

PGM2

PGM2

2119

2119

@

2220

@

PGM2

End PLU/
UPC code

Ç

For reading all codes

2221

2221

For individual reading
Start
PLU code

178

@

2220

@

2221
Set PLUs

2119, 2219

For reading all codes
For individual reading

2220

Start PLU/
UPC code

5

Ç

@

End
PLU code

Ç

6

Mix-and-match
table

PGM2

2225

2225

@

Ç

2225

7

Condiment
table

PGM2

2223

2223

@

Ç

2223

8

UPC’s function

PGM2

2025

2025

@

Ç

2025, 2029

Program for:

Mode
switch
position

Job
code no.

Related job
code nos.

Procedure

@

1050

For reading all codes
For individual reading
Start
UPC code
9

Dynamic UPCs

PGM2 or
PGM1

1050

@

End
UPC code

For the last picking list
Scan UPC code

MDSE
SBTL

Ä

Ç

1050, 1060,
1061, 2059,
2060, 2061,
2064, 2065,
2066, 2067,
2068, 2081,
2094

MDSE
SBTL

UPC code

To pick up UPC codes
10

Dept. /PLU/UPC
group text

PGM2 or
PGM1

2350

2350

@

Ç

2350, 2351

11

Servers/cashiers

PGM2 or
PGM1

1400

1400

@

Ç

1400, 1414,
2410, 2411
2413

12

GLU/PBLU code

PGM2

2800

2800

@

Ç

2810
1310, 1311,
2310, 2311,
2312, 2313,
2314, 2315,
2316, 2320,
2321, 2322,
2326, 2334,
2328, 2330
2614, 2615,
2616, 2617,
2618, 2619,
2620, 2630,
2631, 2632,
2636, 2689,
2690, 2691,
2692

13

Function
preset 1

PGM2 or
PGM1

1300

1300

@

Ç

14

Function
preset 2

PGM2

2600

2600

@

Ç

15

Messages

PGM2

2640

2640

@

Ç

2641, 2642,
2643

16

Tax tables and
rates

PGM2 or
PGM1

2700

2700

@

Ç

2710, 2711

17

Auto keys

PGM2

2900

2900

@

Ç

2900

18

Thermal printer

PGM2

2990

2990

@

Ç

2990

19

Remote printer

PGM2

3650

3650

@

Ç

3653, 3654,
3655, 3656

20

On-line preset

PGM2 or
PGM1

6110

6110

@

Ç

21

CAT preset

PGM2

7110

7110

@

Ç

6110, 6111,
6112, 6113,
6115, 6212,
6213, 6220
7110, 7111,
7112, 7113,
7114, 7115,
7116

179

Sample printouts
1 Reading of programmed items for departments
(Reading in the PGM1 and PGM2 modes)

Job code no.
Range
Dept. code
Item label

Mode switch
position*
Range

Mode switch
position*
PLU code
Commission group

Group no.
HALO limit.
Food stamp
status

2 Reading of programmed items for PLUs/UPCs
(Reading in the PGM1 and PGM2 modes)

Item label
for price
level 1 thru 6

Associated
dept. code

Unit price for
price level
1 thru 6

Tax status
Tax status
Function
Function
programming
programming

Print station

CVM control
character
Remote printer
item label
for price level
1 thru 6
Age limitation

Commission
group
Group

Base q’ty

Minus department

CVM control character
Age limitation

* When you take this report in the PGM1 mode, the PGM2
indication is replaced by “PGM1”.

180

Condiment
table no.
Stock
Mix and match
table no.

Set PLU
L: Link PLU

3 Reading of programmed key nos. for
departments and PLUs
(Reading in the PGM2 mode)

5 Reading of programmed set PLUs
(Reading in the PGM2 mode)

Key no.
Dept. code

Tied
PLU code

6 Reading of mix-and-match table
(Reading in the PGM2 mode)
PLU code
Mix-and-match
table no.
Adjustment amount
Matching count

7 Reading of condiment table
(Reading in the PGM2 mode)

Table no.
Assigned
PLU code
Next condiment table no.

Number of repeats

4 Reading of programmed items for link PLUs
(Reading in the PGM2 mode)

8 Reading of programmed UPC’s function
(Reading in the PGM2 mode)

Range
Leading
PLU code

Linked
PLU code

Non-PLU code
format
Delete period for
non-accessed UPC

181

9 Reading of programmed Dynamic UPC
(Reading in the PGM1 and PGM2 mode)

Mode switch
position*

The subsequent printout occurs in the same
format as in the sample reading of
programmed items for PLUs/UPCs.

11 Reading of programmed items for servers/cashiers
(Reading in the PGM1 and PGM2 modes)

Server/cashier
name
Server/cashier
no.

Mode switch
position*
Server/cashier
code
Drawer no.
GLU/PBLU/
manual PC/CB
entry
Net sale %

* When you take this report in the PGM1 mode,
the PGM2 indication is replaced by “PGM1”.

* When you take this report in the PGM1 mode, the
PGM2 indication is replaced by “PGM1”.

10 Reading of programmed department and
PLU/UPC group text
(Reading in the PGM2 mode)

Department
group no.
Text

PLU group no.

182

12 Reading of programmed GLU/PBLU code
(Reading in the PGM2 modes)

13 Reading of programmed items for functions - 1
(Reading in the PGM1 and PGM2 modes)

To be continued on the next page

* When you take this report in the PGM1 mode,
the PGM2 indication is replaced by “PGM1”.

183

184

14 Reading of programmed items for functions - 2
(Reading in the PGM2 mode)

Logo message

Line feed for tray subtotal

Optional feature selection

Drawer open alarm time

Scale tare tables

Hourly report format/start
hour
Stacked report
Secret code
Bill number
Power saving mode

RS-232C channel data
Barcode reader data
Remote printer data

185

15 Reading of programmed messages
(Reading in the PGM2 mode)

Guidance/error
messages

Check validation
message

Slip printer’s logo
message

To be continued

186

16 Reading of programmed tax tables and rates
(Reading in the PGM2 mode)

19 Reading of remote printer preset
(Reading in the PGM2 mode)

Tax rate

Tax table

Tax rate
Lowest taxable
amount

20 Reading of ON-LINE preset
(Reading in the PGM2 mode)

17 Reading of programmed items
for auto keys
(Reading in the PGM2 mode)

21 Reading of CAT preset
(Reading in the PGM2 mode)
18 Reading of programmed items for the thermal
printer (Reading in the PGM2 mode)

Printing density
Entered Value

Printing density
example

187

13 Universal Product Code (UPC) or European Article Number (EAN)
UPC or EAN code
Your machine can support the following codes:
• UPC-A (Number system character: 0, 2, 3, 4, 5)
• UPC-E
• EAN-8
• EAN-13
• Internal code EAN-8/EAN-13
For the codes used in-store marking, there are two types of PLU type (treated as a code like PLU no.) and NonPLU type (price/quantity information is included in the code).
When a code is non-PLU type, the price/quantity in the code is read for sales entry (in case of quantity, “quantity
multiplys preset unit price” is processed to obtain price.)

UPC-A
• Number system character: 0 
• Number system character: 3 
• Number system character: 5 
For entry, a full 12 digit number or 11 digit number (omitting the
check digits) must be entered.

C

0
Maker code

Check digit

Number system character

C

3

C

Maker code

2

Family
code

*
Item code

*

*

*

C

D

Price check digit

• UPC-E is a zero-suppressed version of UPC-A that conforms to
the UPC-E Standards. This code is used for marking small
packages.
For entry, a 6 digit number or a leading zero plus 6 digits number
must be entered.

EAN 8
• Ordinary EAN-8 code (flag: neither 0 nor 2) 
For entry, a full 8 digit number must be entered.

C

D

Maker code
Nation code

Item code

C

2

188

*

Price

UPC-E

For entry, a full 8 digit number must be entered. On the
receipt/journal, non-PLU type code is printed like 208**** (****:
price/quantity information)

D

Coupon
price table

4
For entry, a full 12 digit number, 11 digit number (omitting the
(Free code)
check digit), or a leading zero plus 12 digit number must be
entered.(Any numbers are allowed for the digits marked with *,
and on the receipt/journal, non-PLU type code is printed like 2020008**** (****: price information).)

• Internal code (flag 2) 
Program the format by the job #2025.
• Internal code (flag 0) 

D

NCD (or HRI) format

5

• Number system character: 2 
You can program the format by the job #2025.
• Number system character: 4 

D

Item code

D

(Free format)
Program the format by the job#2025.
C

0
(Free code)

D

C

D

EAN-13
• Ordinary EAN-13 code (used in the source marking)
• Specific EAN-13 code (flag 977, 978, 979) (used in the source
marking: ISBM, ISSN)

C

Maker code

D

Item code

Nation code

For entry, you must enter a full of 13 digits number.
• Internal code (used in the in-store marking, the flag character
number: 20 through 29 and 02)
Program the format by the job# 2025.

C

Flag
02, 20-29

D

(Free format)
Program the format by the job #2025.

Add-on code
UPC-A and EAN-13 may be followed by a two digits number or a five digits number as add-on code, excepting
UPC-A without a check digit plus two or five digits add-on code.
Therefore, the total number of digits enterable for sales entries are as shown below:

Note

Code entry

No add-on code

2-digit add-on code

5-digit add-on code

UPC-A

12

14

17

UPC-A w/leading zero

13

15

18

UPC-A w/o check digit

11

–

–

UPC-E

6

–

–

EAN-8

8

–

–

EAN-13

13

15

18

Your register automatically judges the add-on code in an UPC/EAN code entered from the total
number of digits and the flag.

189

READING (X) AND RESETTING (Z)
OF SALES TOTALS
• Use the reading function (X) when you need to take a reading of sales information entered since the last
resetting. You can take this reading any number of times. It does not affect the register’s memory.
• Use the resetting function (Z) when you need to clear the register’s memory. Resetting prints all sales
information and clears the entire memory except for the GT1 thru GT3 and training GT, reset count, and
consecutive number.
• If you want to stop the printing report, turn the mode switch to the MGR position. The symbol (“
”) is
printed.

Summary of reading (X) and resetting (Z) reports and the key operations

1 to obtain the reports

X1 and Z1 reports: Daily sales reports
X2 and Z2 reports: Periodic (monthly) consolidation reports
Item

Flash report:
(Only display)
To clear the display,
press the
key
or turn the mode
switch to another
position.

c

Mode switch
position
X1/Z1
X2/Z2

Job
code

Key operation

99 )
1 to ÿ
: Department total amount
Dept. code
à
@ key: Amount of cash in drawer
t key: Paid total
Dept. key (

X1

—

—

X1, Z1

X1, Z1

100

General report

X1, Z1

X2, Z2

200

X1, Z1

141

X2, Z2

Individual cashier/
server report

241

Reading

100
200

.

@

Reading

141
241

Ç

Resetting

.

For assigned cashier/server

@

Cashier/server code

@

Ç

@

Ç

Ç

Resetting
Reading

 X, Z

41

41

.
Resetting

Full cashier/server
report

X1, Z1

Reading

X1, Z1

140

X2, Z2

240

140
240

Full department
report

X1

X1
X2

110
210

110
210

Individual group
total report on
department

X1

X1

112

X2

212

Full group total
report on
department

X1

X1

113

X2

213

.
Resetting

Ç

112
212

@
@

113
213

@

Ç

Group number

Ç

Reading

X1, Z1

X1, Z1

120

PLU/UPC
report by
designated range

.

@

Resetting

All PLUs/UPCs

X2, Z2

190

120
220

220

Start PLU/
UPC code
Scan UPC code

@
Ä

End PLU/
UPC code
Scan UPC code

Ä

Ç

Item

Mode switch
position
X1/Z1
X2/Z2

Job
code

Key operation
Reading

X1, Z1

X1, Z1

109

109
209

.

For full reading and resetting

Resetting

For the last picking list
PLU/UPC report
by pick up list

@
X2, Z2

Scan UPC code

Ä

PLU/UPC
code

209

Ç

MDSE
SBTL

MDSE
SBTL

To pick up PLU/UPC codes
PLU/UPC report
by associated
department

X1, Z1

Individual group
total report on
PLU/UPC

X1

Full group total
report on PLU/UPC

X1

PLU/UPC zero
sales report by
department

X1

X1

Reading

X1, Z1

121

X2, Z2

221

X1

122

X2

222

X1

123

X2

223

X1

127

X2

227

127
227

X1

129

129
229

121
221

.

@

122
222

@

Group number

123
223

@

Ç

Ç

Full reading

@
@

PLU/UPC price
category report

Ç

Dept. code

All prices
X2

229

Start price
amount
124

PLU/UPC stock
report

Ç

Dept. code

Resetting

End price
amount

@

Ç

@
All PLUs/UPCs

X1

X1

124
Start PLU/
UPC code
Scan UPC code

@
Ä

End PLU/
UPC code

Ç

Scan UPC code

Ä

For full reading
For the last picking list
PLU/UPC stock
report by pick up list

104
X1

X1

104

@

Scan UPC code
PLU/UPC
code

MDSE
SBTL

Ç

Ä
MDSE
SBTL

To pick up PLU/UPC codes

191

Item

Mode switch
position
X1/Z1
X2/Z2

Job
code

Key operation
Reading

180
GLU/PBLU report

X1, Z1

X1, Z1

.

@

Resetting

180

All GLU/PBLUs

@

Start GLU/
PBLU code
Reading

GLU/PBLU report by
cashier/server

X1, Z1

X1, Z1

181

181

.

Ç

End GLU/
PBLU code

For assigned cashier/server

@

Cashier/server code

Ç

Resetting
Reading

182
Closed GLU/PBLU
report

X1, Z1

X1, Z1

.

@

Resetting

182

All bills

@

Start bill #
Closed GLU/PBLU
report by cashier/
server
Commission sales
report
Tax report

Reading

X1, Z1

X1, Z1

183

.

For assigned cashier/server

@

Cashier/server code

Ç

Resetting

X1

X1

X1

X1

132

X2

232

X1

133

X2

233

X1

130

X2

230

X1

131

X2

231

Transaction report

Cash in drawer
report

183

Ç

End bill #

X1

132
232

@

Ç

133
233

@

Ç

130
230

@

Ç

131
231

@

Ç

Reading

169

.

@

Resetting

Dynamic UPC report
by designated range

X1, Z1

X1, Z1

All UPCs

169
Start UPC
code
Scan UPC code

@
Ä

Ç

End UPC
code
Scan UPC code

Ä

Reading

165

.

For full reading and resetting

Resetting

For the last picking list
Dynamic UPC report
by pick up list

X1, Z1

X1, Z1

165

@

Scan UPC code
UPC code

MDSE
SBTL

Ä
MDSE
SBTL

To pick up UPC codes

192

Ç

Item
Dynamic UPC report
by associated
department

Mode switch
position
X1/Z1
X2/Z2

Job
code

Key operation
Reading

X1, Z1

X1, Z1

166

166

.

@

Ç

Dept. code

Resetting
Reading

168

.

@

Resetting

Dynamic UPC clear
report by
designated range

X1, Z1

X1, Z1

All UPCs

168
Start UPC
code
Scan UPC code

@
Ä

Ç

End UPC
code
Scan UPC code

Ä

Reading

164

.

For full reading and resetting

Resetting

For the last picking list
Dynamic UPC clear
report by pick up list

X1, Z1

X1, Z1

@

164

Scan UPC code

Ç

MDSE
SBTL

Ä
MDSE
SBTL

UPC code

To pick up UPC codes
Dynamic UPC clear
report by associated
department

Reading

X1, Z1

X1, Z1

167

167

.

@

Dept. code

Ç

Resetting

X1

Reading:
160
(For individual
time range)

X1

@

End*
time

160

Hourly report

X1, Z1

@
Ç

* Enter the time in the 24-hour system.

Reading
and
Resetting:

X1, Z1

Start*
time

Reading

.

160

@

Ç

Resetting

X1, Z1

X1, Z1

Reading

190

Stacked report
X2, Z2

290

X2, Z2

270

190
290

.

@

Ç

@

Ç

Resetting

When Z of stacked report
is initiated, X only reports
will be skipped.

Reading

Daily net report

270

.
Resetting

193

Non-accessed UPC deleting
Mode switch
position
X1/Z1
X2/Z2

Item

Reading of
non-accessed UPCs

X1

X1

Job
code

105

Key operation

105

@

Ç
For full deleting
For the last UPC picking list

Deleting of
non-accessed UPCs

Z1

Z1

105

105

. @

Scan UPC code
UPC code

MDSE
SBTL

Ç

Ä
MDSE
SBTL

To pick up UPC codes

Note

194

When you execute the job #105 in Z1 mode, not only the sales data, but also the UPC code(s) (the
related data files) themselves will be deleted.

2 Daily sales totals
General report
You can take X and Z reports in the X1/Z1 mode. The use of the decimal (.) key determines when the report
will actually reset the totals.
• Sample X report

• Sample Z report
Report no.
Read symbol

Dept. code

Reset symbol
Reset counter
Net grand total
(GT2 - GT3)
Grand total of
plus registration
Grand total of
minus registration

Ratio of dept. 1
sales amount to
“+” real dept. total

Sales q'ty

Grand total of training
mode registration

Sales amount

“+” real dept.
counter and total

The subsequent printout occurs in the
same format as in the X report.

“-” real dept.
counter and total

“+” hash dept.
counter and total

“-” hash dept.
counter and total

“+” bottle return dept.
counter and total

“-” bottle return dept.
counter and total
gas q'ty
“+” gas dept. counter, quantity sold
and amount total

“-” gas dept. counter, quantity sold
and amount total
To be continued on the next page

Note

Not all reports provide the resetting capability. Please refer to the chart on pages 190-194.

195

Subtotal

4 counter and total

Subtotal
total
Subtotal % 3 counter and total

Subtotal % total

Gas discount counter and total (cash 1 - 5)

Gas discount counter and total (check 1 - 5)

Gas discount counter and total (charge 1 - 9)

Gas discount total
Net sales total
Net taxable 1 total
Gross tax 1 total
Refund tax 1 total
Net tax 1 total
Exempt total from tax 1

*1

Gross manual tax total
Refund manual tax total
Net manual tax total
FS tax 1 forgiveness total
FS tax 2 forgiveness total
FS tax 3 forgiveness total

(When the Canadian tax system is selected)

Tax total
Sale total excluding tax
Sales total
including tax
To be continued on the next page

*1 When food stamp function is allowed, tax 4 items are not printed.

196

Exempt
total from
GST
PST total
GST total

Item

1 counter and total

Item 1 total
Item % 1 counter and total
Item % total
Coupon-like PLU counter
and total
Vender coupon UPC counter and total
Eat-in 1 counter and total

Item void counter and total
Subtotal void counter and total
Manager item void counter and total
Void-mode transaction
Refund counter and total
Return counter and total
Hash item void counter and total
Hash item refund counter and total
Hash item return counter and total

*

No-sale (exchange) counter
Validation print counter
Bill counter
Drawer counter
Tray subtotal counter
GLU/PBAL counter
Service counter
Cover counter
Trans-out counter and total
Trans-in counter and total
Customer counter
Average of sales amount
Gratuity total
Sales total (including hash dept. total)
Hash net sales total
Waste total
Cash counter and total

Cash total
Sales for food stamp counter and total
RA1 by cash counter and total
RA1 by check counter and total
RA1 by charge counter ant total
RA1 by food stamp counter and total
RA1 total

RA total

* When manual PB/CB function is enabled, amount is also printed for each print item.

197

PO1 by cash counter and total

PO total
Check cashing 1 counter and total

Check cashing total
Cash change total for check and charge tendering
Cash change total for food stamp tendering
Currency conversion 1 total (by programmed rate)

Currency conversion 4 total (by manual rate)
Currency conversion total
Food stamp in drawer total
Charge 1 counter and total
Charge 1 refund/return counter and total

Charge total
Check 1 counter and total

Check total
Cash + check in drawer
Cash in drawer
Deposit counter and total
Deposit refund counter and total
Tip-paid counter and total
Cash tip counter and total
Charge tip counter and total

198

Cashier/Server report
Using this function, you can take X and Z reports for individual cashiers/servers or all cashiers/servers.
Individual cashier/server reading and resetting
The OP X/Z-mode reading and resetting is allowed only when your machine has been programmed
Note
for "OP X/Z mode available" in the PGM2 mode.
• Sample X report

Cashier
no.

• Sample Z report

Cashier/server code
Cashier/server name
Sales total
Vender coupon UPC
counter and total
Gratuity total
Cash tip total
Charge tip total
Tip-paid total
Customer counter
Cover counter

The subsequent printout occurs in the
same format as in the sample X report.

Commission 1 sales total
Commission 1 amount
(commission 1 sales
total x commission 1 rate)

* When you take these reports in the OP X/Z mode,
the X report shows an “OP X” and the Z report
shows an “OP Z”.

Commission amount total
Non-commission sales
total

Full cashier/server reading and resetting
The printout occurs in the same format as in the sample report of individual cashier/server, but all
cashiers/servers' sales data are printed in the order of cashier/server code number (from #1 to #20), and then
the total of all cashiers/servers is printed.

199

Hourly report
You can take X and Z reports for sales totals and transaction (customer) counters for 48 half hours, or 24 hours.
If both quantity and amount are zero, their print is skipped.
• Sample X report

• Sample Z report

The subsequent printout occurs in the
same format as in the sample X report.
Customer counter
Sales total
Cover counter
Average sales amount per customer
(sales total ÷ customer counter)

200

Full department report

Individual group total report on
department

Sales q’ty

Amount
Ratio of dept. 1 sales
amount to + real
dept. total

Group 1 total

Full group total report on
department

Group 1 total

201

PLU/UPC report (by designated range or pick up list)
This function provides you with X and Z reports for sales information of PLUs/UPCs.
You can select either of the designated range operation or pick up list operation. The range may represent all or
part of the PLUs/UPCs in your register.
• Sample X report

• Sample Z report

Range*1
PLU code
Item label for
price level 1

Item label for
price level 2

Sales q'ty and total
(for price level 1)
Waste mode q'ty and total*2
The subsequent printout occurs in the same
Net sales q'ty and total*2
format as in the sample X report.
Net sales %

Note

*1: The PLU/UPC range is not printed in pick
up report (#109).
*2: Not printed when waste mode is disabled

PLU total for price level 1

PLU total for price level 2

202

UPC code

UPC total for price level 1

UPC total for price level 6

203

PLU/UPC report by associated department
• Sample X report

• Sample Z report

The subsequent printout occurs in the same
format as in the sample X report.

The subsequent printout occurs in the
same format as th ePLU/UPC report by
designated range.

Individual group total report on
PLU/UPC

PLU code
Item label
for price
level 1

Full group total report on
PLU/UPC

Group text
Sales q'ty and
amount for
price level 1

Sales q’ty and
amount for
PLU group 11

Group 1 sales q'ty
and amount

204

PLU/UPC zero sales report by
department

PLU/UPC stock report (by
designated range or pick up list)

Associated
dept. code*
Item label

PLU code

Range

Current stock

* When printing full zero sale report,
no associated dept. code is printed.

PLU/UPC price category report
Note

The PLU/UPC range is not printed in pick
up report (#104).

Price amount
range
Sales q’ty
and total
(for price
level 1)

Commission sales report

Commission 1
(sales total)
Commission 1
(amount)

Commission amount
total
Non-commission sales
Net sales total

205

GLU/PBLU report
• Sample Z report

• Sample X report

GLU/PBLU
code
Cover
counter

Range
Cashier/server
code

The subsequent printout occurs in the same
format as in the sample X report.

GLU/PBLU report by cashier/server
• Sample X report

• Sample Z report

The subsequent printout occurs in the same
format as in the sample X report.

206

Closed GLU/PBLU report
• Sample X report

• Sample Z report

The subsequent printout occurs in the same
format as in the sample X report.

207

Closed GLU/PBLU report by cashier/server
• Sample X report

• Sample Z report

The subsequent printout occurs in the same
format as in the sample X report.

208

Transaction report

Cash in drawer report
You can take full cashier X reports for cash in
drawer.

Cashier no.
Cashier name
Customer counter
Sales total
Cash in drawer
In this report the same transaction data as those
printed when general reading is taken are printed
except department sales totals.

Tax report

*1

*2
*3

*1 Not printed when food stamp function is allowed.
*2 Printed only when Canadian tax is selected.
*3 Not printed when Canadian tax is selected.

209

Dynamic UPC report (by designated range or pick up list)
The printout occurs in the same format as in the sample report of PLU/UPC report (by designated range or pick
up list) .

Dynamic UPC report by associated department
The printout occurs in the same format as in the sample report of PLU/UPC report by associated department.

Dynamic UPC clear (by designated range or pick up list)
Please note that the UPCs specified for this report are deleted from the dynamic UPC file when Z report is
issued.
The printout occurs in the same format as in the sample report of PLU/UPC report (by designated range or pick
up list) .

Dynamic UPC clear by associated department
Please note that the UPCs specified for this report are deleted from the dynamic UPC file when Z report is
issued.
The printout occurs in the same format as in the sample report of PLU/UPC report by associated department.

X1/Z1 stacked report
You can print multiple X1/Z1 reports in sequence at a single time. In this case, you need to program in advance
what X1/Z1 reports should be printed in the stacked report sequence.

Note

210

The following job code numbers (only) can be used for stacked report printing.
Job code number: 100, 110, 113, 120, 124, 127, 129, 130, 131, 132, 140, 160, 180
Refer to “Selection of X1/Z1 and X2/Z2 reports to be printed in the stacked report sequence” for
further details.

Deleting of non-accessed UPCs
• Sample X report (Reading)

• Sample Z report (Deleting)

UPC code
Item label
Periodic sales*

The subsequent printout occurs in the same
format as in the sample X report.

*: When there is any sales data of the UPC for #209 report, the data in printed here.
When you delete the UPC in Z1 mode under the this situation, the data for #209 is also deleted.

211

3 Periodic consolidation
Your register allows you to take consolidation X and Z reports of a chosen period (normally one week or a
month).

General Overview
The periodic reading or resetting reports are the same in format as those in the X1/Z1 report for daily total
except job code no. (#2xx) and mode indication (“X2” or “Z2”.)
• Sample X report

• Sample Z report
Reset symbol
Reset counter of daily total
Reset counter of periodic
consolidation

Read symbol

Grand total

The subsequent printouts are the same in format as
those in the X/Z report for daily total.

Daily net report
• Sample X report

• Sample Z report

The subsequent printout occurs in the
same format as in the sample X report.
*

*: Overflowed data will be printed with the
indication of
at the date column.
/

X2/Z2 stacked report
You can print multiple X2/Z2 reports in sequence at a single time. In this case, you need to program in advance
what X2/Z2 reports should be printed in the stacked report sequence.

Note

212

The following job code numbers (only) can be used for stacked report printing.
Job code number: 200, 210, 213, 220, 227, 229, 230, 231, 232, 240, 270
Refer to “Selection of X1/Z1 and X2/Z2 reports to be printed in the stacked report sequence” for
further details.

COMPULSORY CASH/CHECK
DECLARATION
If you want to make the declaration of the cash and check amount in the drawer mandatory before
performing cashier Z reports, please consult your dealer and have your register programmed for
compulsory cash/check declaration.
If your register is programmed for compulsory cash/check declaration (CCD), a cashier must first count and
declare the cash and check amounts (of domestic and foreign currency) in the drawer, before he or she can
performing a cashier report. The procedure for outputting a CCD report is shown below.
Types of compulsory cash/check declarations
• Compulsory declaration prior to individual cashier resetting
• Compulsory declaration prior to full cashier resetting
• Compulsory cash/check declaration is available in the above two types. You can choose either of
these. Please consult your dealer for further details.
• When the cash/check declaration is compulsory, flash reports are not available.

Note

Key operation
After the Ç key is pressed, the register prompts the cashier to input the cash and check accounts for both
domestic and foreign currency. The cashier can simply input the total amounts of each currency unit, or the
number of bills or coins of each denomination of each currency unit.
• Individual cashier report
OP X/Z mode
41

. @

The drawer opens and the cashier is prompted to
enter the cash and check amounts. (“CCD” is displayed.)

Input the check or
currency denomination

=
ç #

X1/Z1 mode
141

. @

Ç

Q’ty

@

X

v

Ç

to

Amount

=
ç #
to

• Full cashier report
X1/Z1 mode
140

. @

Input the total
amount of cash
or check

To cancel
previous
entry

To repeat

t
To display cash/check subtotal

= : When inputting the cash or check amount (domestic currency) in the drawer
ç to # : When inputting the amount of a foreign currency in the drawer

213

CCD entry amount

Currency conversion 1 in drawer to be obtained
Total of entered (declared) conversion 1 in drawer
Difference

Check 1 (in domestic currency) in drawer to be obtained
Cash/check in drawer to be obtained
Total of entered (declared) cash/check in drawer
Difference
Total of difference
Cash in drawer to be obtained

214

OPERATOR MAINTENANCE
1 In case of power failure
When power is lost, the machine retains its memory contents and all information on sales entries.
• When a power failure is encountered in register idle state or during an entry, the machine returns to the normal
state of operation after power recovery.
• When a power failure is encountered during a printing cycle, the register
prints “========” and then carries out the correct printing procedure
after power recovery. (See the sample print.)

2 In case of printer error
If the printer runs out of paper, the printer will hault, “PAPER EMPTY” error will appear on the display. Key
entries will not be accepted. Referring to “4. Installing and removing the paper roll” in this chapter, install a new
roll paper in the proper position, then press the c key. The printer will print the power failure symbol and
resume printing.
If the print head is up, the printer haults, “HEAD UP” error will appear on the display. Key entries will not be
accepted. Bring the print head to the correct position, then press the c key. The printer will print the power
failure symbol and resume printing.

3 Thermal printing
Your register prints by means of thermal printing. The print head applies heat to thermal paper which is
chemically treated to change color when heated to a certain level. This creates the printed text.

Cautions in handling the printer
Printing position

• If you are not going to use the register for an extended
period of time, pull the print head release lever toward you
so that the print head is set apart from the plate.

Head-up
position

215

• Avoid the following environments:
Dusty and humid places
Direct sunlight
Iron powder (A permanent magnet and electromagnet are used in this machine.)
• Use the print head release lever only when necessary.
• Never pull the paper when it is in contact with the print head. First release the head with the print head release
lever, and then remove the paper.
• Never touch the surface of the print head.
• Never touch around the print head and the motor during printing or before they have had sufficient time to cool.

Cautions in handling the recording paper (thermal paper)
• Use only the paper specified by SHARP.
• Do not unpack the thermal paper until you are ready to use it.
• Avoid heat. The paper will color at around 70°C.
• Avoid dusty and humid places for storage. Avoid direct sunlight.
• The printed text on the paper can discolor under the following conditions:
Exposure to high humidity and temperature
Exposure to the direct sunlight
Contact with glue, thinner or a freshly copied blueprint
Heat caused by friction from scratching or other such means
Contact with a rubber eraser or adhesive tape
• Be very careful when handling the thermal paper. If you want to keep a permanent record, copy the printed text
with a photocopier.
• Be very careful when handling the thermal paper. If you want to keep a permanent record, copy the printed text
with a photocopier.
• For the storage of thermal paper, it is recommended to store the paper in a box with a dark and dry
atmosphere of the room temperature 5 to 25°C having no rapid temperature change.

216

4 Installing and removing the paper roll
Recording paper specifications
Be sure to use paper rolls specified by SHARP.
The use of any other paper rolls than specified could cause paper jamming, resulting in register malfunction.
Paper specification
Paper width:
2.26 ± 0.02 in. (57.5 ± 0.5 mm)
Max. outside diameter: 3.15 in. (80 mm)
Quality:
Thermal paper
Paper tube:
0.71 in. (18 mm)
• Be sure to set paper roll(s) prior to using your machine, otherwise it may cause a malfunction.
Install the paper roll in the printer. Be careful then to set the roll and cut the paper end correctly.

Note

If the top end of the paper roll is fixed with paste or tape, the paper may lose its color development
ability in the pasted or taped area due to the deterioration of the heat-sensitive color development
component of the paper surface. This may result in nothing appearing at this location when printing
is performed. Therefore, when setting a new paper roll in the machine, be sure to cut off
approximately one revolution (approx. 25 cm long).

(How to set the paper roll)

(How to cut the paper end)

To the printer

To the printer

Incorrect

Correct
Correct

Incorrect

Installing the paper roll
Installing the receipt paper roll

1. Turn the mode switch to the “REG” position with the AC cord
connected.

2. Remove the printer cover.
3. Check that the print head release lever is in its printing
position.
Printing
position

4. Set the paper correctly as illustrated above in the receipt
side of the printer.

5. Insert the end of the paper into the paper chute as shown on
the left. It will automatically be fed through the printer.

6. Cut off the excess paper that comes out of the printer with
the manual cutter.

7. Replace the printer cover.

217

Installing the journal paper roll

1. Turn the mode switch to the “REG” position with the AC
cord connected.

2. Remove the printer cover.
3. Check that the print head release lever is in its printing
position.

4. Set the paper correctly as illustrated on the previous page in
Printing
position

the journal side of the printer.

5. Insert the end of the paper into the paper chute as shown
on the left. It will automatically be fed through the printer.

6. Insert the end of the paper into the slit in the paper take-up
spool. (Press the Ô key to feed more paper through if
required.)
7. Wind the paper two or three turns around the spool shaft.
8. Set the spool on the bearing.
9. Replace the printer cover.

• When you want to manually install a new roll of paper while your machine is turned off, follow the steps shown
below:
1. Pull the print head release lever toward you to lift up the print head.
2. Correctly place the new paper roll into the receipt/journal paper roll location.
3. Insert the paper end into the paper chute until it comes out of the printer.
4. Cut or roll the paper onto the take-up spool as described for automatic installation.
5. Return the print head release lever to its original position.

Note

If nothing is printed when printing is performed, check the printing face of the paper is at the outer
side. Also in case nothing is printed on the receipt side, please check if the receipt on/off function is
set to on.

Removing the paper roll
When a colored dye appears on the paper roll, it is time to replace the existing paper roll. Replace the paper roll
with a new one. If you plan not to use your register for an extended period of time, remove the paper roll, and
store it in the appropriate place.
Removing the receipt paper roll

1. Remove the printer cover.
2. Cut the paper behind the printer and near the paper roll.
3. Press the ‰ key until the paper remaining in the printer
comes out completely.

4. Remove the paper roll from the back of the printer.
Note

218

Do not pull the paper through the printer.

Removing the journal paper roll

Area to cut

1. Remove the printer cover.
2. Press the Ô key to advance the journal paper until its
printed part is out of the way.

3. Cut the paper and remove the take-up spool.

4. Cut the paper behind the printer and near the paper roll.
5. Press the Ô key until the paper remaining in the printer
comes out completely.

6. Remove the paper roll from the back of the printer.
Note

Do not pull the paper through the printer.

7. Remove the outer side of the take-up spool as shown on the
left.

8. Remove the printed journal roll from the take-up spool.

219

Removing a paper jam
Precaution: Be very careful with the manual paper cutter, so as not to cut yourself. Never touch the
print head immediately after printing, because the head may still be hot.

1. Remove the printer cover.
2. Pull the print head release lever all the way forward (after it
Pull all the
way forward

220

stops at one position, continue pulling forward until it stops
again and cannot be pulled forward any further).
3. Remove the paper jam. Check for and remove any shreds
of paper that may remain in the printer.
4. Return the print head release lever to its original position.
5. Reset the paper roll(s) correctly by following the steps in
“Installing the paper roll”.
6. Replace the printer cover.

5 Cleaning the print head
When the printed text is getting dark or faint, paper dust may be stuck to the print head. Clean the print head as
follows:

1. Turn the mode switch to the “OFF” position.
2. Remove the printer cover.
3. Pull the print head release lever all the way forward (after it
Pull all the
way forward

stops at one position, continue pulling forward until it stops
again and cannot be pulled forward any further).

4. Clean the print head with a soft rag moist with ethyl alcohol
or isopropyl alcohol.
Print head

5. Return the print head release lever to its original position
immediately after cleaning.

6. Reset the paper roll correctly by following the steps in
“Installing the paper roll”.

7. Replace the printer cover.
Caution:
• Never touch the print head with a tool or anything hard as
it may damage the head.
• The paper cutter is mounted on the printer (receipt side).
Be careful not to cut yourself.

221

6 Removing the till and the drawer
The till in the register is detachable. After closing your business for the day, remove the till from the drawer and
keep the drawer open. To detach the drawer, pull it forward fully with the till removed, and remove it by lifting it
up.

Coin case

Till

Drawer

7 Opening the drawer by hand
The drawer automatically opens normally. However, when power failure is encountered or the machine
becomes out of order, slide the lever located on the machine bottom toward the rear. (See the figure below.)
The drawer will not open if it is locked with a drawer lock key.

Lever

222

8 Before calling for service
The malfunctions shown in the left-hand column below, labelled “Fault,” do not necessarily indicate functional
faults of the machine. It is therefore advisable to refer to the “Checking” shown in the right-hand column before
calling for service.
Fault

Checking

(1) The display won’t be illuminated even when
the mode switch is turned to any other
position than “OFF”.
(2) The display is illuminated, but the whole machine
refuses registrations.
(3) No receipt is issued.

(4) No journal paper is taken up.
(5) Printing is unusual.

• Is power supplied to the electrical outlet?
• Is the power cord plug out or loosely connected to the
electrical outlet?
• Is a cashier code assigned to the register?
• Is the mode switch set properly at the “REG” position?
• Is the receipt paper roll properly installed?
• Is there a paper jam?
• Is the receipt function in the “OFF” status?
• Is the print head release lever at the printing position?
• Is the take-up spool installed on the bearing properly?
• Is there a paper jam?
• Is the print head release lever at the printing position?
• Is the paper roll properly installed?

Error message table
Text
no.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17-19
20
21
22
23-26
27
28-29
30
31
32
33
34
35
36
37
38

Description
Registration error
Misoperation error
Desired code is not
programmed yet.
(Reserved)
Secret code error
Code is not free
Memory is full.
Insert slip paper.
The entered server/cashier’s code
is not authorized.
Stock is empty.
Compulsory pushing
the subtotal key
Compulsory tendering
Compulsory GLU/PBLU entry
(Reserved)
Compulsory cover count entry
Check edit error
(for manual PB entry)
(Reserved)
Remote printer off line
(Reserved)
Overlapped server/cashier error
(Reserved)
Power off
(Reserved)
Compulsory tender entry for tip
Compulsory non-add code
The server/cashier is not assigned.
(Reserved)
Overflow limitation
The open price entry is
inhibited.
The unit price entry is
inhibited.
The direct non-tendering
finalization after previous
tender entry is inhibited.
Read error of scale data

In default of
programming
ENTRY ERROR
MISOPERATION

SECRET CODE
NOT FREE
MEMORY FULL
INSERT SLIP

Text
no.
39-47
48
49
50
51
52
53
54
55-60

NO AUTHORITY

61

OUT OF STOCK

62
63
64
65-66
67
68-69
70
71
72-73
74
75

NO RECORD

SBTL COMPUL.
TEND COMPUL.
PB COMPUL.
COV CNT COMP
C/D ERROR
OFF LINE
SERVER ERR.

76

POWER OFF

77
78

TIP ERROR
# COMPULSORY
NOT ASSIGNED

79
80
81

INH. OPEN PR

82-83
84
85

INH. UNIT PR

86

OVER LIMIT.

NOT NON-TEND
SCALE ERROR

87
88
89-93
94

Description
(Reserved)
Enter check number
Enter cover count
(Reserved)
Weight on scale
Closed check file is full.
(Reserved)
Entry of tare weight
(Reserved)
Desired code is not programmed
yet. (learning function)
Enter price and dept. no.
Enter price and dept. no.
Enter dept. no.
(Reserved)
REG buffer is full.
(Reserved)
Price entry at UPC refund
PLU/UPC file is full.
(Reserved)
Non-accessed UPC delete job
(Reserved)
Closing the drawer is
compulsory.
Price level shift error
(Reserved)
Reading of undefined vender
coupon UPC
(Reserved)
Message for prompting entry
of secret code
(Reserved)
Data backup send success
Data backup receive success
Data backup communication
error
Backup data format error
Data backup time out error
(Reserved)
Age limitation error

In default of
programming
ENTER CHECK#
COVER COUNT
WEIGHT
C.FILE FULL
ENTR TARE WT
NO RECORD
PRICE → DEPT
PRICE & DEPT
ENTER DEPT#
BUFFER FULL
ENTER PRICE
UPC FULL
DELETE
CLOSE DRAWER
ENTER P.SFT
OP ENTER

ENTR SECRET#
SEND OK
RECEIVE OK
COM. ERROR
DATA ERROR
TIME OUT
AGE ERROR

223

LIST OF OPTIONS
For your register, the following Sharp options are available.
For further details on additional options that may be considered, please contact your dealer.
•Remote drawer models ER-03DW and ER-04DW
•Till model ER-55CC2 for the standard cash drawer
•Key kit models
By using the following key kits, the keyboard layout can be changed on your register including the
expansion of the number of departments.
ER-11KT7: 30 regular size key kits
ER-12KT7: 30 1 x 2 size key kits
for ER-A520 only
ER-22KT7: 10 2 x 2 size key kits
ER-11DK7G: 30 regular size dummy key kits
ER-51DK7G: 10 5 x 1 size dummy key kits
•Display model UP-P16DP
•RAM board model UP-S02MB

224

SPECIFICATIONS
Model:
Dimensions:
Weight:
Power source:
Power consumption:
Working temperature:
Electronics:
Built-in battery:
Display:
Operator display:
Customer display:
Printer:
Type:
Printing speed:
Printing capacity:
Other functions:

Paper roll:

Cash drawer:
Accessories:

ER-A520/A530
16.6 (W) x 16.8 (D) x 11.7 (H) in. (421 (W) x 427 (D) x 297 (H) mm)
31.7 lbs (14.4 kg)
120V ± 10% AC, 60Hz
Stand-by 11 W
Operating 47 W (max.)
32 to 104°F (0 to 40°C)
LSI (CPU) etc.
Rechargeable battery, memory holding time about 1 month
(with fully charged built-in battery, at room temperature)
LCD dot-matrix display (16 positions x 2 lines)
7-segment display (7 positions)
2-station thermal printer
Approx. 17 lines/second
30 digits each for receipt and journal paper
• Graphic logo printing function
• Logo text printing function
• Receipt (ON-OFF) function, journal selective function
• Receipt and journal independent paper feed function
Width: 2.26 ± 0.02 in. (57.5 ± 0.5 mm)
Max. diam.: 3.15 in. (80 mm)
Quality: High quality (0.06 to 0.08 mm thickness)
5 slots for bill and 5 for coin denominations
Manager key
2
Submanager key
2
Operator key
2
Drawer lock key
2
Printer cover lock key
2
Paper roll
2
Take-up spool
1
Standard key sheet
1 (provided with the keyboard)
for ER-A530 only
Programming key sheet
1 (provided with the keyboard)
Ferrite cores
2 (used for connection cabling installation)
Leaflet
1 copy

* Specifications and appearance subject to change without notice for improvement.

225

NOTICE
BE SURE TO ASK YOUR AUTHORIZED SHARP DEALER ABOUT THE WARRANTY THAT
YOUR SELLING DEALER EXTENDS TO YOU. In order to assure you, the end-user, of warranty
protection, Sharp extends a limited warranty to each of its authorized dealers, and in turn requires
each of its authorized dealers to extend its own warranty to you on terms that are no less favorable
than those given to the dealer by Sharp. You should be aware, however, that Sharp does not itself
extend any warranties, either express or implied, directly to you, the end-user, and no one is authorized to make any representations or warranties on behalf of Sharp. Specifically, SHARP DOES
NOT EXTEND TO YOU, THE END-USER, ANY EXPRESS WARRANTY OR ANY IMPLIED
WARRANTY OF MERCHANTABILITY, FITNESS FOR USE OR FITNESS FOR ANY PARTICULAR PURPOSE IN CONNECTION WITH THE HARDWARE, SOFTWARE, OR FIRMWARE
EMBODIED IN OR USED IN CONJUNCTION WITH THIS PRODUCT. Sharp is not responsible
for any damages or loss, either direct, incidental or consequential, which you, the end-user, may
experience as a result of your purchase or use of the hardware, software or firmware embodied in
or used in conjunction with this product. Your sole remedy in the event that you encounter any
difficulties with the product is against the authorized dealer from which you purchased the product.
In the event that this authorized dealer does not honor its warranty commitments, please contact
the General Manager of Sales, Retail and Financial System Division, ISG, Sharp Electronics Corporation, Sharp Plaza, P.O. Box 650, Mahwah, NJ 07430-2135 so that Sharp can try to help you to
assure complete satisfaction of all the warranty rights to which you are entitled from the authorized
dealer.

ER-A520/A530

ELECTRONIC CASH REGISTER
MODEL

ER-A520
ER-A530
INSTRUCTION MANUAL

SHARP ELECTRONICS CORPORATION
Sharp Plaza, Mahwah, New Jersey 07430-2135
1-800-BE-SHARP
http://www.sharp-usa.com

SHARP CORPORATION

The above illustration shows the model ER-A520.
Printed in Japan
ERA520/A530_MIE10



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Page Mode                       : UseNone
XMP Toolkit                     : 3.1-702
About                           : uuid:05b1f5c6-e100-4732-90c4-894008a8b158
Producer                        : Acrobat Distiller 5.0.5 for Macintosh
Create Date                     : 2004:03:08 07:39:14Z
Modify Date                     : 2010:05:19 11:57-04:00
Metadata Date                   : 2010:05:19 11:57-04:00
Document ID                     : uuid:8482a929-7405-44a9-b6ac-8159c25e4dec
Instance ID                     : uuid:da3b6c4e-c92b-486c-8df5-8e3979d0a6d8
Format                          : application/pdf
Page Count                      : 229
EXIF Metadata provided by EXIF.tools

Navigation menu