Sharp Er A520 Owners Manual
Er-A520-Er-A530-Operation-Manual er-a520-er-a530-operation-manual
2015-03-09
: Sharp Sharp-Er-A520-Owners-Manual-644152 sharp-er-a520-owners-manual-644152 sharp pdf
Open the PDF directly: View PDF .
Page Count: 229
Download | |
Open PDF In Browser | View PDF |
ER-A520/A530 ELECTRONIC CASH REGISTER MODEL ER-A520 ER-A530 INSTRUCTION MANUAL SHARP ELECTRONICS CORPORATION Sharp Plaza, Mahwah, New Jersey 07430-2135 1-800-BE-SHARP http://www.sharp-usa.com SHARP CORPORATION The above illustration shows the model ER-A520. Printed in China KS(TINSE????RCZZ)➀ WARNING FCC Regulations state that any unauthorized changes or modifications to this equipment not expressly approved by the manufacturer could void the user's authority to operate this equipment. Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. CAUTION The AC outlet shall be installed near the equipment and shall be easily accessible. FOR YOUR RECORDS Please record below the model number and serial number, for easy reference, in case of loss or theft. These numbers are located on the right side of the unit. Space is provided for further pertinent data. Model Number Serial Number Date of Purchase Place of Purchase INTRODUCTION Thank you very much for your purchase of the SHARP Electronic Cash Register, Model ER-A520/A530. Please read this manual carefully before operating your machine to gain a thorough understanding of the functions and features offered by this model ECR. Please keep this manual for future reference, it may help you if you encounter operational problems. IMPORTANT • Install your register in a location that is not subject to direct radiation, unusual temperature changes, high humidity or exposed to water sources. Installation in such locations could cause damage to the cabinet and the electrical components. • The register should not be operated by an individual with wet hands. The water could seep into the interior of the register and cause component failure. • When cleaning your register, use a dry, soft cloth. Never use solvents, such as benzine and/or thinner. The use of such chemicals will lead to discoloration or deterioration of the cabinet. • The register plugs into any standard wall outlet (120V ±10% AC) which utilizes a dedicated ground circuit. Please note that other electrical devices on the same electrical circuit could cause the register to malfunction. • If the register malfunctions, call your local dealer for service - do not try to repair the register yourself. • For a complete electrical disconnection, the AC power cord must be removed from the wall outlet. • Never disconnect the peripheral while the register remains plugged into the AC outlet. PRECAUTION This Electronic Cash Register has a built-in memory protection circuit which is supported by rechargeable batteries. It is important to know that all batteries will, in time, dissipate their charge even if not used. Therefore to insure an adequate charge in the protection circuit, and to prevent any possible loss of memory during or after installation, it is recommended that each unit be allowed to recharge for a period of 24 to 48 hours prior to and during use by the customer. In order to charge the batteries, the machine must be plugged in. This recharging precaution can prevent unnecessary equipment malfunctions or service calls. 1 CONTENTS INTRODUCTION ····················································································································································1 IMPORTANT ··························································································································································1 PRECAUTION························································································································································1 CONTENTS····························································································································································2 EXTERNAL VIEW OF THE ER-A520 ····················································································································8 Front view ···············································································································································8 Rear view················································································································································8 EXTERNAL VIEW OF THE ER-A530 ····················································································································9 Front view ···············································································································································9 Rear view················································································································································9 PRINTER······························································································································································10 KEYBOARD ·························································································································································11 1 ER-A520 standard keyboard layout·········································································································11 2 ER-A530 standard keyboard layout·········································································································13 3 Standard key number layout····················································································································15 4 Installing the keyboard sheet (ER-A530) ·································································································16 KEYS AND SWITCHES ·······································································································································17 1 Mode switch and mode keys ···················································································································17 2 Drawer lock key ·······································································································································17 3 Printer cover lock key ······························································································································18 4 Cashier/Server code entry key ················································································································18 5 Receipt ON/OFF function ························································································································18 DISPLAYS ···························································································································································19 1 Operator display ······································································································································19 2 Customer display (Pop-up type) ··············································································································19 FOR THE OPERATOR PRIOR TO ENTRIES ···········································································································································20 1 Preparations for entries ···························································································································20 2 Power save mode ····································································································································21 3 Error warning ···········································································································································21 ENTRIES ······························································································································································22 1 Item entries ··············································································································································22 Single item entries ································································································································22 Repeat entries ······································································································································23 Multiplication entries ·····························································································································24 Successive multiplication entries··········································································································25 Split-pricing entries ·······························································································································26 Single item cash sale (SICS)/single item finalize (SIF) entries·····························································27 Scale entries·········································································································································28 PLU level shift (for direct PLU) ·············································································································30 PLU/UPC price level shift ·····················································································································32 Set PLU entries ····································································································································33 Link PLU/UPC entries···························································································································34 Age verification (Birthday entry) ···········································································································34 Mix-and-match entries ··························································································································35 Condiment entries (for PLUs) ···············································································································35 Price inquiry (view) function (for PLU/UPCs)························································································36 UPC learning function···························································································································37 Price change function (for PLU/UPCs) ·································································································38 2 Displaying and printing subtotals ·············································································································40 Merchandise subtotal ···························································································································40 2 Taxable subtotal ···································································································································40 Including-tax subtotal (full subtotal) ······································································································40 Food stamp-eligible subtotal·················································································································40 Tray subtotal·········································································································································40 Eat-in subtotal·······································································································································40 Gasoline discount subtotal ···················································································································40 3 Finalization of transaction ························································································································41 Cash or Check tendering······················································································································41 Mixed tendering (check + cash)············································································································41 Cash or Check sale that does not need any tender entry ····································································42 Charge (credit) sale ······························································································································42 Mixed-tender sale (cash or check tendering + charge tendering) ························································42 4 Food stamp calculations ··························································································································43 Food stamp tendering···························································································································43 Food stamp status shift ························································································································44 5 Tax calculations ·······································································································································45 Automatic tax········································································································································45 Manual tax ············································································································································45 Automatic-tax delete·····························································································································46 Tax status shift ·····································································································································47 6 Guest check (GLU/PBLU) ·······················································································································48 GLU/PBLU system ·······························································································································48 Deposit entries······································································································································51 Transferring guest checks out or in (Transfer-out/in) ···········································································52 Bill totalizing/bill transfer ·······················································································································53 Bill separating ·······································································································································54 Manual Previous Balance(PB) and Charge Balance(CB) entry ···························································55 7 Auxiliary entries ·······································································································································57 Percent calculations (premium or discount) ·························································································57 Discount entries····································································································································58 Refund entries ······································································································································59 Return entries ·······································································································································59 Refund sales mode·······························································································································60 Printing of non-add code numbers ·······································································································60 Gratuity ·················································································································································61 8 Payment treatment ··································································································································62 Tip-in entries·········································································································································62 Tip editing ·············································································································································63 Tip paid entries ·····································································································································63 Currency conversion·····························································································································64 Received on account entries ················································································································65 Paid out entries·····································································································································65 No sale (exchange) ······························································································································65 Cashing a check ···································································································································66 Bottle return ··········································································································································66 9 Automatic sequencing key entries ···········································································································66 10 WASTE mode ··········································································································································67 CORRECTION ·····················································································································································68 1 Correction of the last entry (direct void)···································································································68 2 Correction of the next-to-last or earlier entries (indirect void)··································································68 3 Subtotal void ············································································································································69 4 Correction of incorrect entries not handled by the direct or indirect void function ···································69 CORRECTION AFTER FINALIZING A TRANSACTION (AFTER GENERATING A RECEIPT)························70 OVERRIDE ENTRIES ··········································································································································71 OVERLAPPED CASHIER/SERVER ENTRY ······································································································72 SPECIAL PRINTING FUNCTIONS······················································································································73 1 Copy receipt printing································································································································73 3 2 Validation printing function (Slip printer) ··································································································74 3 Bill printing ···············································································································································74 4 Printing of the employee’s arrival and departure times (Slip printer) ·······················································74 5 Printing of header and footer graphic logos·····························································································75 6 Remote printer send function ··················································································································75 TIME DISPLAY AND AUTOMATIC UPDATING OF THE DATE ········································································76 1 Time display ············································································································································76 2 Automatic updating of the date ················································································································76 FOR THE MANAGER PRIOR TO PROGRAMMING ·······························································································································77 1 Programming keyboard layout·················································································································77 2 How to program alphanumeric characters·······························································································78 Using character keys on the keyboard ·································································································78 Entering character codes······················································································································78 PROGRAMMING ·················································································································································80 Basic instructions··································································································································80 Preparations for programming··············································································································80 Direct Programming ···········································································································································80 1 Setting the date and time·························································································································80 Date ······················································································································································80 Time······················································································································································81 2 Programming for departments ·················································································································81 Unit price ··············································································································································81 Functional selection······························································································································82 3 PLU/UPC programming ···························································································································84 Unit price ··············································································································································84 Functional selection······························································································································85 Associated department·························································································································86 4 Programming for discount keys (-) ······································································································87 Discount amount ··································································································································87 Functional programming·······················································································································87 5 Programming for percent keys (%)········································································································88 Percent rate ··········································································································································88 Functional programming·······················································································································89 6 Programming for conversion keys (ç) ··································································································90 Currency conversion rate ·····················································································································90 7 Programming for the r, p, and † keys ···························································································90 High amount lockout (HALO)················································································································90 8 Programming for the a, CA , ', and k keys···················································································91 High amount lockout (HALO) and function selection············································································91 9 Programming for the automatic tax calculation function ··········································································93 The tax table (applicable to the add-on tax) ·························································································93 Job-Code-Based Programming ························································································································96 1 Setting the date and time·························································································································96 Setting the date (#2610) ·······················································································································96 Setting the time (#2611) ·······················································································································96 2 Setting the register and consecutive numbers ························································································97 Setting the register number (#2612)·····································································································97 Setting the consecutive number (#2613)······························································································97 3 Programming for the automatic tax calculation function ··········································································98 The tax table (#2710) ···························································································································98 The tax rate (#2711) ···························································································································100 Doughnut tax exempt (for the Canadian tax system) (#2715)····························································101 4 Programming for departments ···············································································································102 Functional programming 1 (#2110) ····································································································102 4 Functional programming 2 (#2111) ····································································································104 A limit amount (HALO) of entry (#2112) ·····························································································105 Item label (#2114)·······························································································································105 Unit price (#1110) ·······························································································································106 Commission group assignment (#2115)·····························································································106 Group number (#2116) ·······················································································································107 Group text (#2350) ·····························································································································107 Age limitation (#2180)·························································································································108 Print station assignment (#2118)········································································································108 Department key positioning (#2119)···································································································109 Color Video Monitor (CVM) control character (#2158) ·······································································109 5 PLU/UPC programming ·························································································································110 Associated department (#1200, 2230, 1050) ·····················································································111 Unit prices (#1210, 1060) ···················································································································113 Base quantity (#1211, 1061) ··············································································································114 Functional programming 1 (#2210, 2231, 2060) ················································································114 Functional programming 2 (#2211, 2232, 2061) ················································································116 Item label (#2214, 2064)·····················································································································118 Commission groups (#2215, 2235, 2065) ··························································································119 Group number (#2216, 2066) ·············································································································120 Group text (#2351) ·····························································································································120 Age limitation (#2280, 2236, 2081)·····································································································121 Stock quantity (#1222, 1220, 1221)····································································································122 Set PLU (#2221)·································································································································123 Mix-and-match table (#2217, 2225, 2067)··························································································124 PLU condiment table (#2222, #2223)·································································································125 Print station to PLU/UPC assignment (#2218, 2068) ·········································································127 Delete period for non-accessed UPC codes (#2029) ·········································································128 Programming Non-PLU code format (#2025)·····················································································129 Link PLU/UPC link (#2220)·················································································································130 Programming of PLU levels and direct PLU keys (#2219) ·································································130 Item label for remote printer (#2244, 2094) ························································································131 Color Video Monitor (CVM) control character (#2258, 2234, 2059) ···················································132 6 Programming for miscellaneous keys····································································································133 CA CH , TIP ) and discount (-) (#1310) ····································133 Rate (%, ç, commission, gratuity, TIP Gas discount unit price (#1311)··········································································································134 Currency description text (ç) (#2334)······························································································134 CA CH , TIP , r, p) (#2312) ····················135 A limit amount (HALO) of entry (-, † (for manual tax), TIP +/– sign, food stamp status and tax status (%, -, gratuity) (#2311)··············································136 Percent entry type (%) (#2310) ········································································································137 Item % or subtotal % selection (%) (#2315) ·····················································································138 Percent rate limitation (%) (#2313)···································································································138 Vendor or store coupon selection (-) (#2316)·················································································139 7 Programming for the media keys···········································································································140 Functional programming 1 (#2320) ····································································································140 Functional programming 2 (#2326) ····································································································142 High amount lockout (HALO) for check cashing, check change, and cash in drawer (#2321)···········143 High amount lockout (HALO) of entry for media keys (#2322)···························································143 Print station assignment (#2328)········································································································144 CAT programming (#2330)·················································································································145 8 Programming of function text·················································································································146 Programming (#2314)·························································································································146 List of function texts····························································································································146 9 Server/Cashier programming ················································································································150 Server/Cashier code (#1400) ·············································································································150 Server/Cashier name (#1414) ············································································································150 5 Functional programming (#2410) ·······································································································151 GLU/PBLU code range assignment (#2411) ······················································································151 Net sales % rate (#2413)····················································································································152 10 Programming various functions ·············································································································152 Programming for optional feature selection (#2616) ··········································································152 Programming the parameter of the slip printer (#2615)······································································157 Setting the time limit for THE TILL TIMERTM (#2617) ·········································································158 Scale tare table (#2618) ·····················································································································158 Programming of logo messages (#2614) ···························································································159 Selection of X1/Z1 and X2/Z2 reports to be printed in the stacked report sequence (#2620)············160 Setting the time range for hourly reports (#2619)···············································································161 Programming of power save mode (#2689) ·······················································································161 Available GLU/PBLU codes (#2810) ··································································································162 Bill number (#2636) ····························································································································162 Functional programming for the printer (#2990) ·················································································163 Editing guidance/error messages (#2641)··························································································163 Validation message (#2642)···············································································································165 Slip printer’s logo message (#2643) ···································································································165 RS-232C channel assignment (#2690) ······························································································166 Barcode reader programming (#2691) ·······························································································167 Remote printer assignment (#2692) ···································································································168 Second remote printer assignment (#3653) ·······················································································168 Remote printer name (#3654) ············································································································169 Print format for remote printer (#3655) ·······························································································169 Chit receipt format (#3656)·················································································································170 RS-232C interface (#6110, 6111, 6112, 6113, 6115, 6212, 6213, 6220)···········································171 Programming the CAT interface (#7110, 7111, 7112, 7113, 7114, 7115, 7116)································173 Secret codes to control access to the PGM1 mode, X1/Z1 mode and X2/Z2 mode (#2630, 2631, 2632) ···························································································································175 Loading dynamic UPCs to the main UPC file (#2099)········································································175 Setting the AUTO key (#2900) ···········································································································176 11 TRAINING mode ···································································································································177 12 Reading stored programs ······················································································································178 Program details and procedures for their reading ··············································································178 Sample printouts·································································································································180 13 Universal Product Code (UPC) or European Article Number (EAN) ·····················································188 UPC or EAN code·······························································································································188 Add-on code ·······································································································································189 READING (X) AND RESETTING (Z) OF SALES TOTALS···············································································190 1 Summary of reading (X) and resetting (Z) reports and the key operations to obtain the reports ··········190 2 Daily sales totals····································································································································195 General report ····································································································································195 Cashier/Server report ·························································································································199 Hourly report·······································································································································200 Full department report ·······················································································································201 Individual group total report on department························································································201 Full group total report on department ·································································································201 PLU/UPC report (by designated range or pick up list)········································································202 PLU/UPC report by associated department ·······················································································204 Individual group total report on PLU/UPC ··························································································204 Full group total report on PLU/UPC····································································································204 PLU/UPC zero sales report by department ························································································205 PLU/UPC price category report ··········································································································205 PLU/UPC stock report (by designated range or pick up list) ······························································205 Commission sales report ····················································································································205 GLU/PBLU report ·······························································································································206 GLU/PBLU report by cashier/server ···································································································206 6 Closed GLU/PBLU report ···················································································································207 Closed GLU/PBLU report by cashier/server·······················································································208 Transaction report ······························································································································209 Tax report ···········································································································································209 Cash in drawer report ·························································································································209 Dynamic UPC report (by designated range or pick up list)·································································210 Dynamic UPC report by associated department ················································································210 Dynamic UPC clear (by designated range or pick up list) ··································································210 Dynamic UPC clear by associated department ··················································································210 X1/Z1 stacked report ··························································································································210 Deleting of non-accessed UPCs·········································································································211 3 Periodic consolidation····························································································································212 General Overview·······························································································································212 Daily net report ···································································································································212 X2/Z2 stacked report ··························································································································212 COMPULSORY CASH/CHECK DECLARATION······························································································213 OPERATOR MAINTENANCE ···························································································································215 1 In case of power failure ·························································································································215 2 In case of printer error ···························································································································215 3 Thermal printing·····································································································································215 Cautions in handling the printer··········································································································215 Cautions in handling the recording paper (thermal paper) ·································································216 4 Installing and removing the paper roll····································································································217 Recording paper specifications ··········································································································217 Installing the paper roll ·······················································································································217 Removing the paper roll ·····················································································································218 Removing a paper jam ·······················································································································220 5 Cleaning the print head ·························································································································221 6 Removing the till and the drawer ···········································································································222 7 Opening the drawer by hand ·················································································································222 8 Before calling for service ·······················································································································223 Error message table ···························································································································223 LIST OF OPTIONS ············································································································································224 SPECIFICATIONS ·············································································································································225 7 EXTERNAL VIEW OF THE ER-A520 Front view Customer display (Pop-up type) Printer cover Receipt paper Operator display Journal window Keyboard Mode switch Drawer Drawer lock Rear view Printer cover lock (left side) Rear cover 8 EXTERNAL VIEW OF THE ER-A530 Front view Customer display (Pop-up type) Printer cover Operator display Receipt paper Journal window Keyboard Mode switch Drawer Drawer lock Rear view Printer cover lock (left side) Rear cover 9 PRINTER The printer is a receipt/journal dual station type thermal printer which delivers fast, quiet and high quality printing. The average life of the printer is approximately 5 million lines. When opening the printer cover, unlock the printer cover using the printer cover lock key, and lift up the cover as shown in the diagram to the right. Printer cover Printer lock key Your register is shipped with the print head release lever held in the up position by a white shipping retainer. Be sure to remove this retainer (see the figure at the right) and push down the print head release lever before you use the register. Retainer Print head release lever The print head can be lifted by the green lever on the right side of the printer. Pulling the lever forward, lifts the print head up. If the paper becomes jammed and you need to move the print head farther forward, you can pull the lever even further toward you and proceed with the removal of the jammed paper. Take-up spool Paper roll location Paper chute Print head release lever Note 10 Do not attempt to remove the paper roll with the head in the down position. This may result in damage to the printer and print head. KEYBOARD 1 ER-A520 standard keyboard layout NC SLIP RCPT PBLU CASH # @ FOR INQ FS AUTO SHIFT 1 .L 5 10 15 20 FS AUTO TEND 2 7 8 9 4 9 14 19 NS CH1 %1 TAX 4 5 6 3 8 13 18 CHK CH2 TAX SHIFT 1 2 3 2 7 12 17 MDSE SBTL SBTL 00 1 6 11 16 PO RFND VOID #/TM 0 CA/AT All keys except the receipt paper feed and journal paper feed keys can be re-positioned. If you want to change the layout, please consult your authorized SHARP dealer. RECEIPT Receipt paper feed key JOURNAL Journal paper feed key 0 AMT CONV RA FINAL %2 Note PRICE CHANGE PLU/UPC 9 Discount 1 key %1 Percent 1 and 2 keys %2 New check key NC Numeric keys 00 • Decimal point key CL Clear key @ Multiplication key RFND Refund key VOID Void key AMT Amount entry key FOR PBLU Previous balance key FINAL Final key No-sale key NS TAX SHIFT TAX 1 shift key TAX Manual tax key MDSE SBTL 1 AUTO 1 Merchandise subtotal key 20 AUTO 2 Department keys Automatic sequencing 1 and 2 keys CASH # Cashier code entry key PLU/UPC PLU/UPC key RA Received-on-account 1 key PLU/UPC inquiry key PO Paid-out 1 key INQ PRICE CHANGE UPC price change key FS SHIFT Food stamp shift key 11 FS TEND Food stamp tender key CA/AT Cash/amount tendered key Charge 1and 2 keys RCPT Receipt print key Currency conversion key SLIP Slip printer key CHK Check 1 key #/TM Non-add code/Date & time display key SBTL Subtotal key CH 1 CH 2 CONV Note The following function keys can optionally be mounted in place of those shown in the figure of the standard keyboard layout. For details, please consult your authorized SHARP dealer. Optional keys DEPT # Dept. number key Tip paid key %3 %5 Percent 3 thru 5 keys EAT IN 1 EAT IN 3 Eat in 1 thru 3 keys -2 -5 Discount 2 thru 5 keys TAX2 SHIFT TAX4 SHIFT Tax 2 thru 4 shift keys CH3 CH9 Charge 3 thru 9 keys DEPO Deposit key CA2 CA5 Cash 2 thru 5 keys DEPO RFND Deposit refund key CONV2 CONV4 Currency conversion 2 thru 4 keys LEVEL # PLU level shift number key RA2 Received-on-account 2 key RP SEND Remote printer send key PO2 Paid-out 2 key GRT EXEMPT Gratuity exempt key Automatic sequencing 3 thru 10 keys OPEN TARE Tare entry key SRVC Service key REPEAT Repeat entry key TRAY SBTL Tray subtotal key AUTO 3 AUTO 10 RETURN CHK2 12 TIP PAID CHK5 GAS SBTL Gasoline sales subtotal key Return key P-SHIFT # Price shift number key Check 2 through 5 keys SCALE Scale entry key TRANS OUT Transfer out key L1 L5 PLU level shift 1 thru 5 keys TRANS IN Transfer in key P1 P6 Price level shift 1 thru 6 keys CA TIP Cash tip key CH TIP Charge tip key PRINT CV CNT Validation print key Cover count entry key No delete key C NEXT Condiment next key BS Bill separation key C CANCEL Condiment cancel key BT Bill totalize/Bill transfer key (CHECK-ADD) NO DEL EDIT TIP BIRTH Birthday entry key GLU RECALL RFND SALES Refund sales key 000 WASTE Waste mode key Edit tip key Table# recall key Numeric key The department and direct PLU keys may be expanded. If you require expansion of the department or direct PLU keys, please contact your dealer. Note 2 ER-A530 standard keyboard layout L2 RCPT % VOID INQ RP SEND AUTO 3 RFND PLU/ SUB NC CONV PBAL CH1 8 CL 9 SRVC CH2 4 5 6 FINAL CH3 22 1 2 3 MDSE SBTL CHK 11 0 00 000 SBTL CA/AT JOURNAL 91 92 93 94 95 96 97 98 99 100 79 80 81 82 83 84 85 86 87 88 89 90 67 68 69 70 71 72 73 74 75 76 77 78 56 57 58 59 60 61 62 63 64 65 66 SERV # 45 46 47 48 49 50 51 52 53 54 55 FOR 34 35 36 37 38 39 40 41 42 43 44 7 23 24 25 26 27 28 29 30 31 32 33 12 13 14 15 16 17 18 19 20 21 1 2 3 4 5 6 7 8 9 10 @ Note L3 AUTO 2 • All keys except the receipt paper feed and journal paper feed keys may be re-positioned. If you want to change the keyboard layout, please consult your dealer. • Please note that the price lookup/subdepartment/UPC key (P) and the previous balance key ( PBAL ) are shown as PLU/ and u respectively in this manual. UPC RECEIPT Receipt paper feed key @ FOR Multiplication key JOURNAL Journal paper feed key RCPT Receipt print key RFND Refund key VOID Void key PLU/ SUB Price lookup/subdepartment/ UPC key 0 AUTO 1 L1 RECEIPT 9 Numeric keys 00 • CL 000 Decimal point key Clear key 1 100 Direct price lookup keys 13 L1 L3 NC PLU level shift 1 thru 3 keys AUTO 1 New check key CONV CH 1 AUTO 3 Automatic sequencing 1 thru 3 keys Currency conversion key CH 3 Charge 1 thru 3 keys SRVC Service key FINAL Final key CHK Check 1 key PBAL Previous balance key MDSE SBTL Merchandise subtotal key Discount 1 key SBTL Subtotal key Percent 1 key CA/AT Cash/amount tendered key INQ PLU/UPC inquiry key RP SEND Remote printer send key SERV # Server code entry key % The following function keys can optionally be added in place of those shown in the figure of the standard keyboard layout. For details, please consult your authorized SHARP dealer. Note Optional keys DEPT # CH TIP Charge tip key %2 %5 Percent 2 thru 5 keys TIP PAID -2 -5 Discount 2 thru 5 keys EAT IN 1 EAT IN 3 Eat in 1 thru 3 keys CH4 CH9 Charge 4 thru 9 keys TAX1 SHIFT TAX4 SHIFT Tax 1 thru 4 shift keys CA2 CA5 Cash 2 thru 5 keys DEPO Deposit key CONV2 CONV4 Currency conversion 2 thru 4 keys DEPO RFND Deposit refund key TAX RA1 RA2 Received-on-account 1 and 2 keys PO1 PO2 Paid-out 1 and 2 keys TRAY SBTL RETURN Tip paid key Manual tax key Tray subtotal key AUTO 4 AUTO 10 Automatic sequencing 4 thru 10 keys CHK2 CHK5 Check 2 through 5 keys GAS SBTL Gasoline sales subtotal key TRANS OUT Transfer out key #/TM Non-add code/Date & time display key TRANS IN Transfer in key CA TIP 14 Dept. number key Cash tip key NS SCALE Return key No-sale key Scale entry key LEVEL # PLU level shift number key L4 PLU level shift 4 and 5 keys L5 P-SHIFT # REPEAT Repeat entry key AMT Amount entry key Price shift number key PRICE CHANGE UPC price change key Price level shift 1 thru 6 keys BIRTH Birthday entry key Validation print key RFND SALES Refund sales key CV CNT Cover count entry key WASTE Waste mode key SLIP Slip printer key C NEXT Condiment next key BS Bill separation key C CANCEL Condiment cancel key BT Bill totalize/Bill transfer key (CHECK-ADD) P1 P6 PRINT EDIT TIP Edit tip key NO DEL No delete key GLU RECALL Table# recall key GRT EXEMPT Gratuity exempt key FS SHIFT Food stamp shift key OPEN TARE Tare entry key FS TEND Food stamp tender key Note Department and direct PLU keys can be expanded. If you require expansion of the department or direct PLU keys, please contact your authorized SHARP dealer. 3 Standard key number layout These key numbers are used for positioning of department keys and direct PLU keys. For further details with positioning departments and PLU keys, please refer to pages 109 and 130. This layout can be changed by your dealer. For ER-A520 005 010 015 020 004 009 014 019 003 008 013 018 002 007 012 017 001 006 011 016 15 For ER-A530 111 112 113 114 115 116 117 118 119 120 104 105 106 107 108 109 110 098 099 100 101 102 103 087 088 089 090 091 092 093 094 095 096 097 076 077 078 079 080 081 082 083 084 085 086 065 066 067 068 069 070 071 072 073 074 075 054 055 056 057 058 059 060 061 062 063 064 043 044 045 046 047 048 049 050 051 052 053 032 033 034 035 036 037 038 039 040 041 042 021 022 023 024 025 026 027 028 029 030 031 4 Installing the keyboard sheet (ER-A530) Insert the keyboard sheet between the keyboard cover and the cabinet as illustrated below. Then press the claws at the top of the keyboard cover into the slots in the cabinet. Keyboard sheet Keyboard cover Cabinet Note 16 • Do not spread the keyboard cover too far to avoid tearing the tabs. • Replace the keyboard sheet with a new one if by chance it gets wet. Use of a wet keyboard sheet may cause problems. • Be sure to use only SHARP-supplied keyboard sheets. Thick or hard sheets can make key operations difficult. • Place the keyboard sheet evenly under the keyboard cover. • If you require a new keyboard sheet, please contact your dealer. • The keyboard cover will eventually wear out. If your keyboard cover is dirty or broken, replace the cover with a new one. For details, please contact your authorized SHARP dealer. KEYS AND SWITCHES 1 Mode switch and mode keys The mode switch can be operated by inserting one of the three supplied mode keys – manager (MA), submanager (SM), and operator (OP) keys. These keys can be inserted or removed only when the switch is in the “REG” or “OFF” position. • Manager key (MA) Operative range • Submanager key (SM) SM MA • Operator key (OP) OP The mode switch has these settings: OFF: This mode locks all register operation. No change occurs to register data. OP X/Z: This setting allows cashiers to take X or Z reports for their sales information. It can also be used for displaying the date/time and printing the employee’s arrival/departure times. And it can be used to toggle receipt state “ON” and “OFF” by pressing the q key. (This setting may be used only when your register has been programmed for “OP X/Z mode available” in the PGM2 mode.) REG: For entering sales PGM1: To program those items that need to be changed often: e.g., unit prices of departments, PLUs or UPCs, and percentages. PGM2: To program all PGM1 programs and those items that do not require frequent changes: e.g., date, time, or a variety of register functions. MGR: For manager’s and submanager’s entries The manager can use this mode to make entries that are not permitted to be made by cashiers – for example, after-transaction voiding and override entries. X1/Z1: To take the X/Z report for various daily totals. X2/Z2: To take the X/Z report for various periodic (weekly or monthly) consolidation of totals. 2 Drawer lock key SK1-1 This key locks and unlocks the drawer. To lock it, turn 90 degrees counterclockwise. To unlock it, turn 90 degrees clockwise. 17 3 Printer cover lock key This key locks and unlocks the printer cover. To lock it, turn 90 degrees counterclockwise. To unlock, turn 90 degrees clockwise. 4 Cashier/Server code entry key ✱ ✱ ✱ ✱ The ER-A520 provides a cashier system and the ER-A530 provides a server system. The cashier/server codes are available in two variants: Variant 1, the codes are displayed (“0000” to “9999”), and Variant 2, the codes are not displayed (always “ ”). When the cashier/server code is assigned by Variant 2 (codes not displayed), the register prints as the cashier/server code and the cashier/server name are printed both on the receipt and journal for every transaction. ✱ ✱ ✱ ✱ Procedure ■ Sign-on ■ Sign-off Variant 1 / Variant 2 : To display the current cashier/server code ‹/‹ ‹/‹ SERV Variant 1 : (Code is displayed.) Variant 2 : (Code is not displayed.) Note Cashier/server code ‹/‹ SERV ‹/‹ ‹/‹ Cashier/server code SERV SERV SERV All settings depend on how the register has been programmed. For the available selection of these settings, please consult your authorized SHARP dealer. 5 Receipt ON/OFF function You can disable receipt printing in the REG mode to save paper using the receipt function. To disable receipt printing, press the q key in the OP X/Z position. This key toggles the receipt printing status ON and OFF. To check the receipt printing status, turn the mode switch to the OP X/Z position or press the c key in the REG mode. When the function is in the OFF status, the receipt off indicator “_” illuminates. Note 18 Your register will print reports regardless of the receipt status. This means that the receipt roll must be installed even when the receipt state is “OFF” when taking reports. DISPLAYS 1 Operator display The operator display consists of a two-line dot-matrix display (16 characters/line). Price level / PLU level (e.g. P2L3) Dept. name / PLU or UPC name / function text Cashier/server code or mode name Function message display area Numeric entry display area Receipt OFF indicator (“_”) / Stock alarm indicator (“•”) Repeat / Sentinel mark / Power save mark • Cashier/server code or mode name The mode you are in is displayed. When a cashier/server is assigned, the cashier/server code is displayed in the REG or OP X/Z mode. For example, “0001” is displayed when cashier/server 0001 is assigned. • Repeat The number of repeats is displayed, starting at “2” and increments with each repeat. When you have registered an item ten times, the display will show “0”. (2 ➞ 3 ......9 ➞ 0 ➞ 1 ➞ 2...) • Sentinel mark When amounts in the drawer reaches the amount you preprogrammed, the sentinel mark “X” is displayed to advice you to remove the money to a safe place. • Power save mark When the cash register goes into the power save mode, the power save mark (decimal point) is displayed. • Stock alarm indicator When the stock counter of the PLU or UPC which you entered is zero or negative, the alarm indicator (decimal point) is displayed. • Function message display area Item labels of departments and PLU/subdepartments/UPC and function text you use, such as %1, (–) and CASH are displayed here. For the details of function texts, please refer to pages 146 to 149. When an amount is to be entered or entered, “AMOUNT” is displayed: When an amount is to be entered, – – – – – – – is displayed in the numeric entry display area with “AMOUNT”. When a preset price has been set, the price is displayed in the numeric entry display area with “AMOUNT”. • Numeric entry display area Numbers entered using numeric keys are displayed here. Date and time display Date and time appear on the display in the OP X/Z, REG, or MGR mode. In the REG or MGR mode, press #/ the TM key to display the date and time. Error messages When an error occurs, the corresponding error message is displayed in the function message display area. For the details of error messages, please refer to the “Error message table” on page 223. 2 Customer display (Pop-up type) 19 FOR THE OPERATOR PRIOR TO ENTRIES 1 Preparations for entries Before registrations, insert the operator key into the mode switch and turn it to the REG position and check the following items: Receipt and journal paper rolls If the receipt and journal paper rolls are not set in the machine or there are low rolls, install new ones according to section “4. Installing and removing the paper rolls” under “OPERATOR MAINTENANCE.” Receipt ON/OFF function You can disable receipt printing in the REG mode to save paper using the receipt function. To disable receipt printing, press the q key in the OP X/Z position. This key toggles the receipt printing status ON and OFF. To check the receipt printing status, turn the mode switch to the OP X/Z position or press the c key in the REG mode. When the function is in the OFF status, the receipt off indicator “_” illuminates. Note Your register will print reports regardless of the receipt state. This means that the receipt roll must be installed even when the receipt state is “OFF” when taking reports. Cashier/Server assignment The ER-A520 requires a cashier to be assigned prior to operational item entries. The ER-A530 enforces that a server must enter their code into the register. Depending on register settings, it is possible to keep the same cashier/server code assigned when the same cashier/server is to be used for all transactions within a set period. As previously mentioned, there are two variants to consider for the display and print of the cashier/server codes. Logo message or graphic logo (varies depending on programming.) ✱ ✱ ✱ ✱ Cashier/Server code (“ ” is printed in Variant 2.) Cashier/Server name Note 20 The operation entries depend on how the register has been programmed. To determine which selections should be considered, please consult your local dealer. Procedure ■ Sign-on ■ Sign-off Variant 1 / Variant 2 : To display the current cashier/server code ‹/‹ ‹/‹ SERV Variant 1 : (Code is displayed.) Variant 2 : (Code is not displayed.) Note Cashier/server code ‹/‹ SERV ‹/‹ ‹/‹ Cashier/server code SERV SERV SERV • If you want to enter a cashier/server code before every transaction, please consult your authorized SHARP dealer. • For the display type selection of the cashier/server code, “Variant 1” has been preset. For the selection of the “Variant 2”, consult your authorized SHARP dealer. • The cashier/server can be changed during a transaction. Please consult your authorized SHARP dealer. 2 Power save mode The register will enter into the power save mode when no entries are performed based on the pre-programmed time limit (by default, 30 minutes). When the register goes to the power save mode, the operator and customer displays will turn off. This is indicated by a decimal point at the left most position of the lower line. The register will return to normal operation mode when any key is pressed or a mode is changed with the mode key. Please note when the register is recovered by any key entry the initial key entry is ignored. After the recovery, you may start the key entries from the beginning. 3 Error warning In the following examples, your register will go into an error state accompanied with a warning beep and a corresponding error message. Clear the error state by pressing the c key and take proper action. Please refer to the error message table on page 223. • When you enter an over 32-digit number (entry limit overflow): Cancel the entry and re-enter a valid number. • When you make an error in key operation: Clear the error and continue entries. • When you make an entry beyond a programmed amount entry limit: Check to see if the entered amount is correct. If it is correct, it be possible to make the entry in the MGR mode. Contact your manager. • When an including-tax subtotal exceeds eight digits: Clear the subtotal by pressing the c key and press the a, Å thru É, k, CHK2 thru CHK5 , or h thru CH9 key to finalize the transaction. 21 ENTRIES Note The example entries provided within this manual describe the function key labeled PLU/ which is UPC used for the model ER-A520. For the model ER-A530, please substitute the PLU/ key with the P UPC function key. 1 Item entries Single item entries Procedure Department entries (direct department entries) Enter a unit price and press a department key. If you use a programmed unit price, press a department key only. When using a programmed unit price *Less than the programmed upper limit amounts Unit price * (max. 7 digits) Note Department key When those departments for which the unit price has been programmed as zero (0) are entered, only the sales quantity is added. Department entries (indirect department entries) When using a programmed unit price Dept. code (1–99) à Unit price * (max. 7 digits) à å or *Less than the programmed upper limit amounts When [preset only dept.] is entered. PLU entries (indirect PLU entries) Enter a PLU code and press the PLU/ key. UPC PLU/ UPC PLU code Note When those PLU’s for which the unit price has been programmed as zero (0) are entered, only the sales quantity is added. Subdepartment (open PLU, open and preset PLU) entries When using a programmed unit price PLU code PLU/ UPC Unit price * (max. 7 digits) PLU entries (direct PLU entries) When using a programmed unit price Unit price * (for subdept.) 22 Direct PLU key PLU/ UPC or å *Less than the programmed upper limit amounts UPC entries Scan UPC code Ä PLU/ UPC UPC code (max.13 digits) (Registration) To cancel the learing function entry To set “auto-delete” Unit price (max. 6 digits) c When the dept. key is depressed directly NON DELETE ( å Example Key operation 1~ 99 Dept. no. (1 - 99) ) DEPT # Print 1200 3 5 8à 5 à 680 à PLU/ 2P UPC PLU/ PLU/ 11 P 1200 UPC UPC P ô PLU/ 5012345678900 P UPC a Repeat entries You can use this function for entering a sale of two or more same items. You can use the è key to repeat entry instead of department, å, direct PLU or Example Key operation Repeated department entry (direct) Repeated department entry (indirect) Repeated PLU entry (indirect) Repeated PLU entry (direct) Repeated subdepartment entry Repeated UPC entry Repeated department entry (direct) using the repeat key PLU/ UPC key. Print 200 8 8 8 5 à 680 à à 10 P P P ó ó 60 P 500 P P 5012345678900 P P 600 2 è è a PLU/ UPC PLU/ UPC PLU/ UPC PLU/ UPC PLU/ UPC PLU/ UPC PLU/ UPC PLU/ UPC 23 Multiplication entries Use this feature when you need to enter two or more same items. This feature helps when you sell a large quantity of items or need to enter quantities that contain decimals. Procedure When using a programmed unit price Q’ty @ Unit price Department key Dept. code à Unit price Dept. entry (direct) à å or Dept. entry (indirect) When [preset only dept.] is entered. PLU code PLU/ UPC PLU code PLU/ UPC Unit price PLU entry (indirect) Unit price Direct PLU key Ä PLU/ UPC or å PLU/subdept. entry (indirect) PLU/subdept. entry (direct) Scan UPC code UPC entry UPC code PLU/ UPC • After scanning a UPC code or pressing the PLU/ UPC key, when the item does not exist in the file, the display will show “NO RECORD”. Enter the unit price using the å key and department no. with the à key. • Q’ty: Up to four digits integer + three digits decimal • Unit price: Less than a programmed upper limit • Q’ty × unit price: Up to seven digits Example Key operation Department entry (direct) Department entry (indirect) PLU entry (indirect) PLU entry (direct) Subdepartment entry UPC entry Print 7 . 500 @ 165 8 2@ 5à 250 à 15 @ PLU/ 13 P UPC 8 . 250 @ ò 3@ PLU/ 60 P UPC PLU/ 100 P UPC 5@ PLU/ 5012345678900 P UPC a Note 24 You must use a decimal point (.) key when entering quantities that are fractional. Successive multiplication entries This function may be desired when you enter a sale of items sold by area (square feet). Procedure When using a programmed unit price @ Length Width Dept. code @ à Unit price Unit price Department key à å or Dept. entry (direct) Dept. entry (indirect) When [preset only dept.] is entered. PLU code PLU/ UPC PLU code PLU/ UPC Unit price PLU entry (indirect) Unit price PLU/ UPC or å Direct PLU key Ä PLU/subdept. entry (indirect) PLU/subdept. entry (direct) Scan UPC code UPC entry UPC code PLU/ UPC • After scanning a UPC code or pressing the PLU/ UPC key, when the item does not exist in the file, the display will show “NO RECORD”. Enter the unit price using the å key and department no. with the à key. • Length or width: Up to seven digits (4-digit integer + 3-digit decimal) • Unit price: Less than a programmed upper limit • Length × Width × Unit price: Up to seven digits Note • For actual use of this function, please consult your dealer. • You must use a decimal point (.) key when entering quantities that are fractional. Example Key operation Department entry PLU entry Subdepartment entry UPC entry Print 3@ 4@ 400 5 1 . 500 @ 2 . 500 @ PLU/ 8P UPC 1 . 750 @ 1 . 750 @ PLU/ UPC 6P PLU/ UPC 600 P 4@ 5@ PLU/ UPC 5099887654302 P a 25 Split-pricing entries You may use this function when your customer wants to purchase items normally sold in bulk. Procedure When using a programmed unit price @ Selling q’ty Base q’ty @ Unit price per base q’ty Dept. code Department key à Unit price à å or When [preset only dept.] is entered. PLU code PLU/ UPC PLU code PLU/ UPC Unit price per base q’ty Direct PLU key Unit price per base q’ty PLU/ UPC or å PLU/ UPC or å Ä UPC code Only when you use a base q’ty programmed for PLU code PLU/ UPC PLU code PLU/ UPC PLU code PLU/ UPC Unit price per base q’ty Direct PLU key Unit price per base q’ty Ä UPC code PLU/ UPC • After scanning a UPC code or pressing the PLU/ UPC key, when the item does not exist in the file, the display will show “NO RECORD”. Enter the unit price using the å key and department no. with the à key. • Selling quantity: Up to four digits integer + three digits decimal • Base quantity: Up to two digits (integer) Example Key operation Department entry PLU entry UPC entry Print 7@ 10 @ 600 7 8@ 5@ PLU/ 35 P UPC 5@ 6@ PLU/ UPC 5045678912304 P a Note 26 You must use the decimal point (.) key when entering selling quantities that are fractional. Single item cash sale (SICS)/single item finalize (SIF) entries SICS entries • This function is useful when a sale is for only one item and is for cash; such as a pack of cigarettes. This function is applicable only to those departments that have been set for SICS or to their associated PLUs, subdepartments or UPCs. • The transaction is finalized and the drawer opens as soon as you press the department key, å key, PLU/ UPC key, the direct PLU key or scanning a UPC code. Example Key operation Print 250 For finishing the transaction Note 9 If an entry to a department, PLU/subdepartment or UPC set for SICS follows entries to departments, PLUs/subdepartments or UPC not set for SICS, it does not finalize and results in a normal sale. SIF entries • If an entry to a department, PLU/subdepartment or UPC set for SIF follows entries to departments, PLUs/subdepartments or UPC not set for SIF, the transaction is finalized immediately as a cash sale. • Like the SICS function, this function is available for single-item cash settlement. Example Key operation Print 1745 8 1500 For finishing the transaction 9 27 Scale entries For making entries for weighed items, a scale may be connected where by the weight is automatically read from the scale. To make refund or return entries, the weight is entered manually while the scale platter is empty and reads zero. i) Auto scale entries Procedure When using a programmed unit price When base wt. is 1 LB (or 1 KG) Unit price per base wt. Dept. code Department à When you use a programmed tare no. Tare number (1-9) OPEN TARE Unit price à å or When [preset only dept.] is entered. SCALE Base wt. ` Unit price per base wt. Dept. code Open tare weight Department à Unit price à å or When [preset only dept.] is entered. PLU code PLU/ UPC PLU code PLU/ UPC Unit price per base wt. Direct PLU key Unit price per base wt. PLU/ UPC or å PLU/ UPC or å Ä UPC code Only when you use a base wt. programmed for PLU code PLU/ UPC PLU code PLU/ UPC PLU code PLU/ UPC Unit price per base wt. Direct PLU key Unit price per base wt. Ä UPC code PLU/ UPC • Open tare weight: Up to 5 digits (integer + decimal) • Net weight: Up to 5 digits (integer + decimal) • Base weight: Up to 2 digits (integer) Note • The register can be programmed with up to nine tare tables and allows different tares to be assigned to them. • When the S key is pressed, the weight is automatically read from the connected scale (option) and the net weight appears in the register display. • When the item is programmed for “Scale compulsory”, it is not necessary to press the S key. Example Key operation S 200 1 S1P c PLU/ UPC 28 Print ii) Manual scale entries of refunded items Procedure When using a programmed unit price When base wt. is 1 LB (or 1 KG) Unit price per base wt. Dept. code Department à Unit price à å or When [preset only dept.] is entered. Net weight Ï RETERN Ï SCALE Base wt. ` Unit price per base wt. Dept. code Department à Unit price à å or When [preset only dept.] is entered. PLU code PLU/ UPC PLU code PLU/ UPC Unit price per base wt. Direct PLU key Unit price per base wt. PLU/ UPC or å PLU/ UPC or å Ä UPC code Only when you use a base wt. programmed for PLU code PLU/ UPC PLU code PLU/ UPC PLU code PLU/ UPC Unit price per base wt. Direct PLU key Unit price per base wt. Ä UPC code PLU/ UPC • Net weight: Up to 5 digits (integer + decimal) which is from the customer’s receipt. • Base weight: Up to 2 digits (integer) Example Key operation Print 32 . 85 Ï S 200 1 PLU/ 37 . 25 Ï S 1 P UPC c 29 PLU level shift (for direct PLU) This shift function can allow access to PLUs on your register without adding additional direct PLU keys. You can use direct PLUs in five levels by utilizing PLU level shift keys l thru L5 . The level shift key shifts the PLU level from the other four to the required level. (The normal level is level 1.) You can also shift PLU level by entering a level number and pressing the PLU level shift number key, ä. You must program your machine in the PGM2 mode to select one of the two PLU level shift modes — automatic return mode* and lock shift mode** — and decide whether to allow PLU level shift in both the REG and MGR modes or in the MGR mode alone. * The automatic return mode automatically shifts the PLU level back to level 1 after a direct PLU key is pressed. You can select whether the PLU level should return each time you enter one item or each time you finalize one transaction. ** The lock shift mode holds the current PLU level until a PLU level shift key is pressed. Automatic return mode (for PLU levels) If you shift the PLU level while in the automatic return mode, press the desired PLU level shift key before numeric entries. Procedure • each item ¬ thru L5 Numeric entry Level no. (1 to 5) ä @ (Q’ty, Direct PLU (Returning to level 1) Direct PLU Payment ) • each transaction ¬ thru L5 Numeric entry Level no. (1 to 5) ä (Q’ty, @ (Returning to level 1) ) Lock shift mode (for PLU levels) If you shift the PLU level while in the lock shift mode, press the desired PLU level shift key before numeric entries. Procedure To shift the level of another PLU l thru Level no. (1 to 5) Note 30 L5 Numeric entry ä (Q’ty, @ Direct PLU (Staying in the current level) ) If you select the automatic return mode, it is not necessary to use the l key on the keyboard, but if you select the lock shift mode, it is necessary to use the key. Example Direct PLU1: PLU code 1 (PLU level 1), PLU code 65 (PLU level 2) Direct PLU2: PLU code 2 (PLU level 1), PLU code 66 (PLU level 2) • When your machine has been programmed for the automatic return mode: Key operation Print 1 ¬1 2 1 a • When your machine has been programmed for the lock shift mode: Key operation Print l1 ¬1 2 1 a 31 PLU/UPC price level shift Six different price level shifts can be programmed for each PLU or UPC. The price levels can be changed for PLU or UPC registrations. You can change a PLU/UPC price among six prices by utilizing the price level shift keys P1 thru P6 , the level shift key shifts the price level from the other five to the required level. (The normal level is level 1.) You can also a shift price level by entering level number and pressing the price level shift number key, ¥. You must program the price level shift mode (i.e. automatic return mode* or lock shift mode**) and the operating mode to be used for the price level shift (i.e. both REG/MGR modes or MGR mode alone). * The automatic return mode automatically shifts the PLU/UPC price level back to level 1 after a PLU/UPC shift entry. You can select whether the price level should return each time you enter one item or each time you finalize one transaction. ** The lock shift mode holds the current PLU/UPC price level until pressing the price level shift key. Automatic return mode (for price levels) If your register has been programmed for the price level shift in the automatic return mode, press a desired price level shift key before a numeric type entry. Procedure (each item) Ä P2 thru P6 Numeric entry Level no. (1 to 6) ¥ (Q ty, @ PLU/UPC code PLU/ UPC etc.) (Returning to price level 1) Direct PLU (each transaction) Ä P2 thru P6 Numeric entry Level no. (1 to 6) ¥ (Q ty, @ PLU/UPC code PLU/ UPC Payment etc.) Direct PLU (Returning to price level 1) Lock shift mode (for price levels) If your register has been programmed for the price level shift in the lock shift mode, press a desired price level shift key before a numeric type entry. Procedure To shift the price level of another PLU/UPC Ä P1 thru P6 Numeric entry Level no. (1 to 6) Note 32 ¥ (Q ty, @ PLU/UPC code etc.) PLU/ UPC Direct PLU • If you select the automatic return mode, it is not necessary to use the P1 key on the keyboard, but if you select the lock shift mode, it is necessary to use the key. • You can program “printing of the price level text. Please refer to “Programming for optional feature selection” described in the “PROGRAMMING” section of this manual. Example PLU price level 1: PLU 1 ($1.91), PLU 2 ($0.79) PLU price level 2: PLU 1 ($2.00), PLU 2 ($0.99) • When your register has been programmed for the automatic return mode (by one item): Key operation P2 Print PLU/ 1P UPC PLU/ 1P UPC PLU/ 2P UPC a • When your register has been programmed for the lock shift mode: Key operation Print UPC 1P PLU/ UPC 1P PLU/ UPC 2P PLU/ P2 a Set PLU entries Operations are the same as normal PLU’s. When a set PLU is entered, an entered or preset amount is printed as the unit price and then those PLUs linked to the set PLU are printed automatically. Example Key operation Print p a Note The unit price of the set PLU (ex. PLU 20) is the registered amount of the set PLU. The tied PLU’s memory is updated only by the entered quantity. 33 Link PLU/UPC entries The operation is the same as normal PLU’s/UPC’s. When this PLU/UPC is entered, the linked PLU’s amount is included and the linked PLU’s label is printed automatically. Only the 1st PLU is affected by the status shift keys TAX ( SHIFT , |, «, » or ˛ key). The percent calculation is in effect for the amount of the 1st ranking PLU. Example When PLU 21 is linking PLU 25,26,27 as follows Key operation Print PLU/ UPC 21 P a Age verification (Birthday entry) The age verification function is used for prohibiting the sale of goods (departments, PLUs or UPCs) for certain aged persons based on a registered birthday. When a department/PLU/UPC for which a figure other than zero (01 to 99) has been programmed as the age limitation is entered, a birthday entry must be completed. Procedure XXXXXX BIRTH Birthday (five or six digits) Note • A birthday entry can be performed two or more times at any point during a transaction, however the last entered birthday remains in effect. • You can enter the date as far back as 98 years. [Ex.] When the current year is 2005 : you can enter the year 1907-2005. Example Oct. 2, 1985 (When dept. 7 is programmed as the age limitation “17”.) Key operation Print 100285 BIRTH 7 300 7 a When birthday printing is allowed, through programming (Job no. 2616), the birthday date is printed. 34 Mix-and-match entries This function is convenient for matching several PLU/UPC items and selling them in a lump (e.g. bundle sale, multi-packed sale, etc.). The matching q’ty and adjusted amount are assigned to a mix-and-match table. All items that are programmed into the same table are treated as if they belong to one group. Example Selling on a mix-and-match basis the following items in table no. 1 to which the matching q’ty “3” and the adjusted amount “$10.00” are assigned: • PLU 40 (Unit price: $5.00) • PLU 41 (Unit price: $3.00) • PLU 42 (Unit price: $2.50) Key operation Print Treated as $5.00 item ➝ / Treated as $3.00 item ➝ ! Treated as $2.00 item ➝ @ a Condiment entries (for PLUs) Your register may be programmed for prompting condiment and preparatory instructions for a menu-item PLU. Example: When you enter a menu-item PLU, a prompting message such as “HOWCOOK?” will appear. You must specify a PLU such as “RARE” to meet a special order of the guest. In an example of the condiment table show below, it is assumed the condiment table #1 and #4 is assigned to PLU 210 (item label: STEAK/unit price: $13:00). When you enter PLU 210, the message “HOWCOOK?” will appear. You are allowed to enter one of the PLU code, 221, 222 and 223. When you enter PLU 221, “RARE” is registered and the next message “POTATO?” will appear. When you enter PLU 226, “P.CHIPS” is registered. Then press the a key to end this entry. Table number PLU codes for condiment entry (programmed text, price) 1 220 (HOWCOOK?) 221 (RARE 0.00) 222 (MED.RARE 0.00) 223 (WELLDONE 0.00) 4 225 (POTATO?) 226 (P. CHIPS 0.60) 227 (MASHED.P 0.60) 228 (BAKED.P 0.50) Menu-item PLUs (PLU210 is linked to table #1) Example Message text Next table no. 4 Condiment PLUs (preset price entry is allowed.) Key operation Print 210 P 221 P 226 P c PLU/ UPC “HOWCOOK?” appears. PLU/ UPC “POTATO?” appears. PLU/ UPC 35 • Your register will continue to prompt for the condiment entry until you finish the entire condiment entry programmed for the PLU. During the condiment entry, if you enter a normal PLU, which is not in the condiment table, an error message will appear in case the condiment entry is compulsory. C • When the NEXT key is pressed, the entry skips to the next table which is programmed. C • When the CANCEL key is pressed, its condiment entry is canceled in the programmed mode (REG/MGR or MGR). • When you enter a PLU priced at “0.00,” only the text will be printed on the receipt. • No refund entry is possible for any condiment entries. When you perform a refund entry with a menu-item PLU and the condiment PLUs assigned to the menu-item PLU are automatically registered as a refund entry. C • You may omit the compulsory condiment entry by pressing the NEXT key. Note Price inquiry (view) function (for PLU/UPCs) You can use this function when you want to know the unit price of the PLU/UPC item during sales transactions while in the REG/MGR mode. Procedure "VIEW" is displayed. Numeric entry Ù (Q'ty ` ) The total sales amount of the PLU/UPC is displayed. Scan UPC code Ä UPC code *1 PLU/ UPC c å *2 PLU code PLU/ UPC PLU/ or UPC Unit price å *3 (MGR mode) Unit price Unit price Direct PLU å *1: Press the c key to cancel the inquiring (view) mode. *2: Press the å key when you want to register the unit price of the PLU/UPC displayed. *3: You can change the unit price temporarily in the MGR mode. The unit price which is programmed in PGM mode is not changed (Price override entry). For the repeat entry, use the è key. Note Example Key operation Print P Ù 5089123456708 P å c 5 Price is displayed. 36 PLU/ UPC PLU/ UPC UPC learning function When you enter or scan an undefined code, you are required to enter the unit price “amount” and the associated department. The UPC code, unit price and the department entered are stored in the dynamic UPC file (if opened, and if not opened, in the PLU/UPC file) and is used for future sales entries. Note • When there is no capacity remaining in the file, the data is not stored in the file. • The text of the entered department is applied to the entered UPC code. • You can use the UPC learning function in the training mode. This may be convenient to practice when installing the scanning system. Procedure "NO RECORD" is displayed and the beep sound occurs three times. Then, "PRICE -> DEPT" is displayed to guide you to enter unit price and associated department code. Scan an undefined UPC code Ä Undifined UPC code When the unit price is zero, or in case of non-PLU type UPC code having price info. or press code. * PLU/ UPC Ì Unit price Department key å c Dept. no. à To cancel the operation "ENTER DEPT#" is displayed * Press the Ì key when you want to exempt the UPC code entered from the non-accessed UPC delete function (deletion occurs by executing #105 in Z1 mode). Note For the repeat entry, use the è key. Example “NO RECORD”, “PRICE -> DEPT” are displayed. Key operation Print PLU/ 5056789123404 Û UPC 750 5 c 37 Price change function (for PLU/UPCs) You can use this function when you need to change the unit price or associated department of a PLU/UPC item in REG/MGR mode. There are two methods for price changes: 1. Price change mode You can change the preset price and/or the associated department of a PLU/UPC item without entering PGM mode. 2. Changing a price during a transaction When a wrong PLU/UPC price and/or associated department is found during transaction, you can correct them at the time of the transaction. With the entry of a new price and/or associated department, the preset price and/or associated department is automatically changed to the new price and/or associated department. Note For the Non-PLU type price embedded UPC-A codes, the prices in the codes have the priority over the preset prices. So, for these codes, a changed price is valid only when the price change is executed. Procedure Price change mode "PRICE CHANGE" is displayed. Scan UPC code Ä Ê UPC code PLU/ UPC PLU code PLU/ UPC Direct PLU Changing a price during a transaction Scan UPC code Ä UPC code PLU code Ê PLU/ UPC PLU/ UPC Unit price PLU/ or UPC Unit price "PRICE & DEPT" is displayed. å Direct PLU Ê To change the unit price only To enter 0 Unit price c To cancel To change the associated dept. directly by depressing the corresponding key Department key å Dept no. à "ENTER DEPT#" is displayed. 38 To change the associated dept. using the dept. no. entry key Example • Price change mode Key operation Print Ê PLU/ 5087654321106 Û UPC 600 Ê • Changing a price during a transaction Key operation Print UPC 5087654321106 Û PLU/ Ê 600 Ê c The journal printer prints the following format in this position. Associated dept. no. Note • When an undefined code is entered in the price change mode, the register results in an error. • When you press the Ê key during a transaction, the UPC entry is voided upon the 1st depression of the Ê key, then you are allowed to enter a correct price and/or associated department. • In case the item label of the UPC is the same as the associated department, the item label is changed to the item label of the new associated department when the associated department is changed. • For the repeat entry, use the è key. 39 2 Displaying and printing subtotals Your register provides these five types of subtotals: Merchandise subtotal Press the  key at any point during a transaction. The net sale subtotal - not including tax - will appear in the display. Taxable subtotal Taxable 1 subtotal TAX Press the SHIFT (') and ı keys in this order at any point during a transaction. The sale subtotal of taxable 1 items will appear in the display. Taxable 2 subtotal Press the | and ı keys in this order at any point during a transaction. The sale subtotal of taxable 2 items will appear in the display. Taxable 3 subtotal Press the « and ı keys in this order at any point during a transaction. The sale subtotal of taxable 3 items will appear in the display. Taxable 4 subtotal Press the » and ı keys in this order at any point during a transaction. The sale subtotal of taxable 4 items will appear in the display. Including-tax subtotal (full subtotal) Press the ı key at any point during a transaction. The sale subtotal including tax will appear in the display. Food stamp-eligible subtotal Press the f key at any point during a transaction. The sale subtotal of items eligible for food stamp payment will appear in the display. Tray subtotal Press the y key during a transaction in the REG or MGR mode. The contents of the tray total itemizer which include tax are printed and displayed. Eat-in subtotal You may press an eat-in key prior to entering a payment. Your register will calculate a subtotal according to the programmed tax exemption status and display the subtotal, the symbol “EAT IN,” and a corresponding caption (“EAT IN 1,” “EAT IN 2,” or “EAT IN 3”). For the transaction with the eat-in subtotal, you must finalize the transaction by making a payment entry. Just after pressing the eat-in key, however, you can cancel the entry of that key by pressing the c key or another eat-in function key. Gasoline discount subtotal Use the following procedure to get a gasoline discount subtotal; amount after gas discount amount is deducted. The gasoline discount subtotal will appear in the display. Number of media to be used for finalization* (1-19) 40 GAS SBTL *: a:1 Å:2 Å3 : 3 Å4 : 4 É:5 k:6 CHK2 : 7 k CHK3 : 8 k CHK4 : 9 k CHK5 : 10 k ( : 11 ) : 12 * : 13 + : 14 , : 15 ,6 : 16 ,7 : 17 ,8 : 18 ,9 : 19 3 Finalization of transaction Cash or Check tendering Press the ı key to get an including-tax subtotal, enter the amount tendered by your customer, then press the a or one of the Å thru É keys if it is a cash tender or press the k or one of the CHK2 thru CHK5 key if it is a check tender. When the amount tendered is greater than the amount of the sale, your register will show the change due amount and the text “CHANGE”. Otherwise your register will show the text “DUE” and a deficit. Make a correct tender entry. Example Your customer pays $10.00 for an including-tax subtotal of $7.35. Cash tendering Key operation Print ı 1000 a Check tendering Key operation Print ı 1000 k Mixed tendering (check + cash) Example Your customer pays $10.00 by check and $5.00 in cash for an including-tax subtotal of $14.56. Key operation Print ı 1000 k 500 a 41 Cash or Check sale that does not need any tender entry Enter items and press the a or one of the Å thru É keys if it is a cash sale or press the k or one of the CHK2 thru CHK5 keys if it is a check sale. Your register will display the total sale amount. Example Selling a $3.00 item (dept. 6) and another $7.15 item (PLU 10) for cash Key operation Print 300 6 PLU/ 10 P UPC a In the case of check 1 sale Charge (credit) sale Enter items and press the corresponding charge keys (h thru Example CH9 ). Selling a $25.00 item (dept. 5) and a $32.50 item (dept. 6) and accepting the payment by charge 1 account Key operation Print 2500 5 3250 6 h Amount tendering operations (i.e., change calculations) can be achieved by the h thru been preset in PGM2 job #2320. CH9 key when it has Mixed-tender sale (cash or check tendering + charge tendering) Example Your customer pays $9.50 in cash and $40.00 by charge 1 for an including-tax subtotal of $49.50. Key operation ı 950 a h 42 Print 4 Food stamp calculations Food stamp tendering If your customer makes payment (or tendering) in food stamps, obtain the food stamp-eligible subtotal* by pressing the f key and make a food stamp tender entry before entering a cash or check tender. Note The food stamp-eligible subtotal* depends upon how your register is programmed based on the food stamp-eligibility of the automatic tax on a sale of items eligible for food stamp payment, or whether your register is programmed to allow the automatic tax to be paid with food stamps or not or to exempt taxation. The example below presupposes that your register has been programmed to exempt taxation. When the amount tendered in food stamps is greater than the food stamp-eligible subtotal: Your register shows two change due amounts in its display. The food stamp change due appears at the left of the display in dollars and the cash change at the right in cents. • When you enter only items eligible for food stamp payment. Example Your customer purchases a $4.25 item (dept.4, taxable 1, eligible for food stamp payment) and another $4.00 item (PLU 34, taxable 2, eligible for food stamp payment) and tenders $10.00 food stamps for them. Key operation Print 425 4 34 P UPC To display the food stamp-eligible subtotal f 1000 f Food stamp change due Cash change due Display shows: Food stamp change Cash change • Mixed sale of an item eligible for food stamps and another item not eligible for food stamps Example Your customer purchases a $2.48 item (dept. 5, taxable 1, eligible for food stamps) and another $5.42 item (dept. 8, nontaxable, ineligible for food stamps) and pays $5.00 in food stamps and $5.00 in cash. Key operation Print 248 5 542 8 f 500 f 500 a Food stamp change due Display shows: Cash change due Food stamp change Cash change 43 When the food stamp tender is smaller than the food stamp-eligible subtotal: • Accept the remainder in food stamps or in cash or check. If your register is programmed to exempt taxation, additional food stamp tender is not allowed. Example Your customer buys a $3.18 item (dept. 5, taxable 1, eligible for food stamps) and another $1.24 item (dept.7, taxable 2, eligible for food stamps) and pays $4.00 in food stamps and the remainder - $1.00 in cash. Key operation Print 318 5 124 7 f To enter the cash tendering of the remainder 400 f 100 a Food stamp status shift Your machine allows you to shift the programmed food-stamp status of each department, PLU/UPC or - thru ±, percent key by pressing the ˛ key prior to those keys. After each entry is completed, the programmed food stamp status is resumed. Example You sell a $2.32 item of dept. 2 (food-stamp eligible) as a food-stamp ineligible item and another $3.18 item of PLU 86 (food-stamp ineligible) as a food-stamp eligible item and accept $4.00 in food stamps and $2.00 in cash. Key operation 232 ˛ 2 PLU/ 86 ˛ P UPC f 400 f 200 a 44 Print 5 Tax calculations Automatic tax When your register is programmed with a tax table (or tax rate) and the tax status of an individual department and PLU/UPC is set for taxable, it computes the automatic tax on any item that is entered directly into the department or indirectly via a related PLU/UPC. Example Selling five $6.70 items (dept. 1, taxable 1) and one $7.15 item (PLU 85, taxable 2) for cash Key operation Print 5@ 670 1 PLU/ 85 P UPC a Manual tax Your machine allows you to enter tax manually after item entries. Example Selling an $8.00 item (dept. 7) for cash with 50 cents as tax Key operation Print 800 7 50 † a 45 Automatic-tax delete You can delete the automatic tax on the taxable 1, taxable 2, taxable 3 and taxable 4 subtotal of each transaction by pressing the † key after the subtotal is displayed. Example Selling a $7.25 item (dept. 1, taxable 1) and another $5.15 item (dept. 3, taxable 2) for cash and entering the sale as a non-taxable one Key operation Print 725 1 515 3 *\ı TAX SHIFT TAX1 * SHIFT for ER-A530 † |ı † a If any of the media keys (i.e. cash, check or charge 1 thru charge 5) are programmed as tax delete in PGM2 mode, the tax can be deleted without using the procedures above. In this case, depressing a corresponding media key alone will always cause the programmed tax to be deleted. Example When the Å key is programmed as tax delete for the same case with the above example Key operation 725 1 515 3 Å 46 Print Tax status shift Your machine allows you to shift the programmed tax status of each department, - thru ≠, percent key or TAX TAX1 the PLU/UPC key by pressing the SHIFT ( SHIFT ), |, « and/or » keys before those keys. After each entry is completed, the programmed tax status of each key is resumed. Example Selling the following items for cash with their programmed tax status reversed • One $13.45 item of dept. 7 (non-taxable) as a taxable 1 item • One $7.00 item of dept. 2 (non-taxable) as a taxable 1 and 2 item • One $4.00 item of dept. 3 (taxable 2) as a non-taxable item • Two $10.50 items of dept. 1 (taxable 1) as taxable 2 items Key operation Print 1345 \ 7 700 \ | 2 400 | 3 1050 \ | 1 TAX SHIFT TAX SHIFT TAX SHIFT 1 a Note The entry of a multi-taxable item for PST or GST will be prohibited as follows (for Canada). In case of; Tax 1: PST, Tax 2: PST, Tax 3: PST, Tax 4: GST Taxable 1 and 2 item ········· prohibited Taxable 1 and 3 item ········· prohibited Taxable 2 and 3 item ········· prohibited Taxable 1 and 4 item ············· allowed Taxable 2 and 4 item ············· allowed Taxable 3 and 4 item ············· allowed In case of; Tax 1: PST, Tax 2: PST, Tax 3: GST, Tax 4: GST Taxable 1 and 2 item ········· prohibited Taxable 1 and 3 item ············· allowed Taxable 2 and 3 item ············· allowed Taxable 1 and 4 item ············· allowed Taxable 2 and 4 item ············· allowed Taxable 3 and 4 item ········· prohibited 47 6 Guest Check (GLU/PBLU) Note Please note that the previous balance key (ufor ER-A520 and PBAL for ER-A530) is shown as u. Two different guest check entry systems are available: the GLU system and previous balance lookup (PBLU) system. It depends on how your register has been programmed which of these is used. Please contact your authorized SHARP dealer for more information about this selection. GLU system: If this system is selected, the balance due and the details of the order are placed in the guest GLU check file. The information can be automatically recalled by pressing the RECALL key, or enteringa GLU code when additional ordering or finalization is required. PBLU system: If this system is selected, the previous balance is stored in the previous balance lookup file (PB lookup file). The information can be automatically recalled by entering a previous balance lookup code (a PBLU code) when additional ordering occurs. GLU/PBLU system New guest For a new guest; Procedure For automatic GLU/PBLU code generation GLU/PBLU code (1-9999) n Cover count entry [Item entries] Partial tendering Amount Note 48 r or A S f [Payment operations] Ω ∏ • The GLU/PBLU code refers to a number/code that will be used whenever the guest check must be accessed for re-ordering or final payment. • The available range of GLU or PBLU codes can be programmed for each chashier/server. • Your register can be programmed to generate GLU/PBLU codes in a sequential fashion. If your register has not been programmed to do so, each GLU/PBLU code can be entered manually. • The cover count refers to the number of people in the party. When the cover count entry is compulsory, you must enter the cover count (max. 2 digits). When cover count is not compulsory, CV enter the cover count and press the CNT key. • When the S key is pressed, the tax is not calculated. • You can temporarily finalize a guest check by pressing the f key. In the GLU system the check will show the current balance including tax while the tax amount is not added to the GLU/PBLU file, and when an additional order is made, the tax amount is recalculated. In the PBLU system, the check will show the current balance including tax and the tax amount is added to the GLU/PBLU file (charge posting), while the guest check is still open. Example Key operation Print 111 n CV 22 CNT 3500 2 2700 3 f Not printed when the S key is f key. pressed instead of the GLU recall GLU Each cashier/server can recall their GLU/PBLUs for reorder or settlement by pressing the RECALL key. The register display GLU/PBLUs from the smallest GLU/PBLU number. Follow the procedure to recall GLUs and select a desired GLU/PBLU code. Procedure GLU RECALL A GLU/PBLU code and the total amount are displayed. #/ TM :To go to the following GLU/PBLU* u :To select L :To cancel GLU recall GLU/PBLU code * When the largest opened GLU/PBLU number is displayed, the smallest GLU/PBLU number is displayed when #/ the TM key is pressed. Example Opened GLU: #111/#112/#113 Selecting GLU#113 and making sales entry of two dept. 7 items ($3.00 and #5.00) Key operation Print GLU RECALL #/ TM Get ready for sales entry #/ TM u 300 7 500 7 f 49 Reorder entries For making additional guest check entries, use the following procedure: Procedure GLU/PBLU code (1-9999) u [Item entries] Partial tendering Amount r or A S f [Payment operations] Ω ∏ Example Key operation Print 111 u 1400 5 1600 6 3000 r c Settlement Use the following procedure: Procedure GLU/PBLU code (1-9999) u [Item entries] Ω ∏ [Payment operations] Example Key operation Print 111 u 5000 k 2000 c Note 50 • You can make a tip-in entry before a tender entry. If a tip-in entry is made, the tip amount must be tendered by using the associated media key e.g. CH1 thru CH9 for the charge tip and CASH 1 or CASH 5 for the cash tip. • Partial tendering is prohibited after tip-in entry operation. Deposit entries Deposit refers to a payment on a charge account. It can be received in cash, check or by charge. You can make the deposit entry only while in a guest check transaction. It cannot be done during handling of a tendered amount. A received deposit can be refunded by pressing the DEPO RFND key. You cannot attempt to refund an amount larger than the deposit balance. Procedure DEPO Deposit amount DEPO RFND Example k c h thru CHK5 thru É thru CH9 To record a $50.00 deposit in cash made by a customer with PBLU code 111 Key operation Print 111 u DEPO 5000 5 Å S Example To refund a $50.00 deposit made by a customer with PBLU code 111 Key operation Print 111 u DEPO 5000 5 RFND Å S 51 Transferring guest checks out or in (Transfer-out/in) Transferring guest checks out At the end of a cashier/server shift or whenever a cashier/server is relieved, one or more open guest checks can be transferred from the cashier/server to the open check file until the responsibility for the check(s) is assigned to another cashier/server. Procedure (cashier/server sign-on) ’ GLU/PBLU code (1-9999) u ’ For the next guest check Example GLU#111 is transferred out. Key operation Print ’ 111 u ’ Transferring guest checks in When the second cashier/server is assigned to be responsible for guest checks that have been transferred out: Procedure Only when cover count entry is non-compulsory (new cashier/server sign-on) ” GLU/PBLU code (1-9999) u Cover count entry (2 digits) For the next guest check Example GLU#111 is transferred in. Key operation ” 111 u ” 52 Print CV CNT ” Bill totalizing/bill transfer Bill totalizing The bill totalizing function is used to totalize multiple bills when, for example, a particular guest pays not only his or her bill, but also the bills of other guests. Procedure j GLU/PBLU code u GLU/PBLU code #1 bill s #2 bill [Sales entries] S f [Payment operations] Example Totalizing GLU#112 and GLU#113 to GLU#111 Key operation Print j 112 u 113 u 111 s S Note • All #1 bills are added to a #2 bill. A maximum of 5 bills may be added to a #2 bill. • The GLU/PBLU code of #1 must be in use. If the guest check(s) of #1 or #2 has already been handled by another server, the guest check(s) must have been made “Transferring out.” 53 Bill transfer This function is used to change the GLU/PBLU code of a particular bill. Procedure j GLU/PBLU code u GLU/PBLU code #1 bill s #2 bill S f [Sales entries] [Payment operations] Example GLU#111 is transferred to GLU #120. Key operation Print j 111 u 120 s S Note • This function requires that the current GLU/PBLU code be entered for #1 and a new GLU/PBLU code be entered for #2. • A #1 bill is transferred to a #2 bill. The #1 bill is then cleared and set free. Bill separating The function is used when each guest of a group pays his or her own order. With this function, you can select some items from a guest check and make an entry for the payment. Also, you can transfer the items you have selected to other guest checks. This function is available only in the GLU system. Procedure To terminate b An item of the original GLU and its quantity are displayed. To go to the following item b GLU code (Original GLU code) u GLU code (For receiving) u #/ TM To enter total q'ty Q'ty @ To terminate S f [Payment operations] 54 b Example One of the dept. 9 items is separated from GLU111 (three dept. 7 items and three dept. 9 items are entered.) Key operation Print b 111 u 117 u Dept. 7 item label and the q’ty are displayed. #/ TM To skip dept. 7 items Dept. 9 item label and the q’ty are displayed. 1@ To select one of dept. 9 items S b Manual Previous Balance (PB) and Credit Balance (CB) entry The register allows you to make manual PB/CB entries. If you use this function, the previous balance amount is entered manually when making new entries that will adjust the original total. This function is not available when you use GLU or PBLU system. To use this function, please contact your authorized SHARP dealer. Note New customers For a new customer, use the following procedure: Procedure n [Item entries] Note Example S f or When the S or f key is pressed, the tax is automatically calculated and printed. The tax is then added to the balance and the new balance is printed. Making a service entry for a dept. 5 item ($87.50) and a dept. 6 item ($62.50) item for a new customer. (A non-add code is used to identify the customer.) Key operation Print n #/ 13579 u TM 8750 5 6250 6 S 55 Customer with previous or credit balance To enter a charge to a customer with a previous or credit balance, use the following procedure: Procedure Check digit*1 (Optional) u n Previous balance*2 Charge balance*3 [Item entries ] S f or *1 Check digit: The number which is printed at the right of the word “SERVICE” on the receipt of the previous entry. (See the previous page. Check with your authorized SHARP dealer for activation of the check digit feature.) *2 Previous balance: In case of the balance is plus or zero *3 Charge balance: In case of the balance is negative Example To make a service entry of 5 dept 7 items (unit price $25.00) for the customer account from the previous example. (non add code number 13579), which has the previous balance $150.00. Key operation Print 3 15000 u #/ 13579 5 TM 5@ 2500 7 Check digit S Settlement Use the following procedure: Procedure Check digit (Optional) Previous balance Charge balance Example u n [Payment operation] The customer (the non add code number 13579) whose previous balance is $275.00 is $27500 pays $200.00 in check and $75.00 in cash. Key operation Check digit 56 [Item entries ] 3 27500 u #/ 13579 5 TM 20000 k 7500 a Print 7 Auxiliary entries Percent calculations (premium or discount) • Your register provides the percent calculation for the merchandise subtotal and item entries. You need to specify in advance whether the register should perform the percent calculation based on the merchandise subtotal or each item entered. • Percentage: 0.01 to 99.99% Percent calculation for the merchandise subtotal Example Selling four $1.40 items of dept. 5 and two $2.25 items of dept. 6; all these items are sold for cash at a premium of 10% (This example presumes that a premium of 10% has been programmed for the % key.) Key operation Print 4@ 140 5 225 6 6  % a Percent calculation for item entries Example Selling for cash an $8.00 item of dept. 6 at a discount of 15% and another $5.00 item of PLU 90 at a discount of 7.5% (This example presumes that a discount of 15% has been programmed for the § key.) Key operation Print 800 6 § PLU/ 90 P UPC 7.5§ a 57 Discount entries For discount or coupon tenderings, you may use the - thru ± key. If the discount or tendered coupon is the one applicable to sales, use the vendor coupon or if it is applicable to each department key, use the store coupon. Discount for the merchandise subtotal Example Selling a $5.75 item of dept. 6 and another $7.50 item of PLU 80 for cash after subtracting the discount amount $1.00 from the total sale amount (This example presumes that the vendor coupon has been programmed for the – key.) Key operation Print 575 6 PLU/ UPC 80 P 100 – a Discount for item entries Procedure Amount Dept. code PLU code UPC code Example Dept. - ± thru - thru thru thru thru Direct PLU ± ± ± ± à Amount PLU/ UPC Amount à å å or PLU/ UPC or PLU/ UPC Ä Selling a $6.75 item of dept. 5 for cash after subtracting the coupon amount 75¢ (This example presumes that the store coupon has been programmed for the - key.) Key operation Print 675 5 75 - * Note 58 * 5 a The - is entered as a modifier for the department which will be netted by the coupon amount. Such item netting coupon entries may generally be entered at any point within a transaction. Two lines are printed for each entry: The first is the label programmed for the - function and the second is related department and - amount. Refund entries If a refund item is the one entered into a department, enter the amount of the refund, then press the Ï key and the corresponding department key in this order; and if an item entered into a PLU (or UPC) is returned, enter the UPC corresponding PLU (or UPC) code, then press the Ï and PLU/ keys, or press the Ï and direct PLU keys without entry of PLU code, in this order. Example Receiving the following items returned: One $2.50 item of dept.5 and seven $2.10 items of PLU 13 Key operation Print 250 Ï 5 7@ PLU/ 13 Ï P UPC a Return entries If a return item is the one entered into a department, enter the amount of the return, then press the RETURN key and the corresponding department key in this order; and if an item entered into a PLU (or UPC) is returned, enter the UPC corresponding PLU (or UPC) code, then press the RETURN and PLU/ keys, or press the RETURN and direct PLU keys without entry of PLU code, in this order. Example Receiving the following items returned: One $3.00 item of dept 1 and one $3.25 item of PLU15 Key operation Print RETURN 1 300 Ï RETURN t 15 Ï PLU/ UPC a Note The returned items are not subjected to the calculation for dept./PLU/UPC items (quantity and amount) on the sales reports. 59 Refund sales mode This function is used for those item return entries relating to departments, PLUs/subdepartments and UPCs. Pressing the ˜ key at the beginning of a transaction causes the register to enter the REFUND SALES mode. All of the REFUND SALES mode entries are automatically handled as refund entries. This mode cannot be finalized by check payment entry. Example Receiving the following items returned: One $2.50 item of dept.5 and seven $2.10 items of PLU 13 Key operation Print ˜ 250 5 7@ PLU/ 13 P UPC a Printing of non-add code numbers Enter a non-add code number such as a customer’s reference number within a maximum of 16 digits and press #/ the TM key at any point during the entry of a sale. Your register will print it at the time of entry. Example Selling a $15.00 item of dept. 5 by charge account to a customer whose code number is 1230 Key operation 1230 = 1500 5 #/ TM h 60 Print Gratuity Calculation When the payment operation is made for sales registrations, the gratuity amount is calculated and printed. You can program a percent rate for calculating the gratuity. If the percent rate is programmed as 0%, the register does not print any gratuity. You can program a tax status (taxable 1/taxable 2/taxable 3/taxable 4/non-taxable) for gratuity. Example When a percent rate of the gratuity is programmed as 10%: Key operation Print 500 5 a Exemption Your register allows you to exempt a customer from the gratuity by pressing the operation. Example GRT EXEMPT key prior to a payment When a percent rate of the gratuity is programmed as 10%: Key operation Print 1250 5 1000 6 GRT EXEMPT a 61 8 Payment treatment Tip-in entries Your register allows the entry of tips that your guests give to cashiers/servers in cash or by credit card. A tip entry must be done before a payment entry. You must use the corresponding media key e.g. CH1 thru CH9 for the charge tip and CASH 1 or CASH 5 for the cash tip. Two different tip-in entry systems are available: the tip amount entry system and the tip percent rate entry system. It depends on how your register has been programmed which of these systems is used. Procedure Tip amount entry system: CA TIP Tip amount CH TIP When you use a programmed percent rate Tip percent rate entry system: Example Tip percent rate (0.01 - 99.99) CH TIP Receiving $3.00 by cash as a tip Key operation 300 Print CA TIP a 62 CA TIP Tip editing This function is used for entering tip amounts after finalizing a guest check with a charge tender. This is only available when the guest check transaction is finalized through CAT authorization and the tip is to be paid in charge tender. The bill number which is issued when the S or f key is pressed in guest check entry must be ED used in order to identify the guest to edit or add tip amount. For the operation, press the TIP key. When the ED display prompt appears, enter the bill number and press the u key, then enter tip amount and press the TIP key again. To use the tip editing function, please consult your authorized SHARP dealer. Tip paid entries This operation is used when tips that guests have paid by using credit card are paid to respective cashiers/servers in cash. To perform a tip paid entry, enter the cashier/server code, then press the † key. You can prohibit the tip paid operation in the REG mode by the PGM2 programming. Note When the tip amount remains unchanged in Individual Server Resetting, the tip paid function is automatically executed and tip receipt is issued to the report printer prior to report printing. 63 Currency conversion Your register allows payment entries of foreign currency. Pressing the ç thru $ key creates a subtotal in foreign currency. Cash payment is the only media that can be handled after currency conversion. Procedure For an additional payment in foreign currency After an entry is completed or After the amount tendered is found smaller than the sales amount in a sales entry. For direct finalization Preset rate *Rate ç " # $ Reentry Amount tendered (max. 8 digits) c a Å thru É Next registration or payment in domestic currency *Rate: 0.000000 to 999.999999 Note When the amount tendered is short, the deficit is shown in domestic currency. Example To convert the amount owed ($69.50) into the designated foreign currency Preset rate (1.325) - CONV 1 Key operation Print 2300 6 4650 7 Currency conversion Amount tendered in foreign currency ç 10000 a Domestic currency Conversion rate Foreign currency Domestic currency Manual rate - CONV 4 (The $ key can be used only for the manual entry.) Key operation 2300 6 4650 7 1 . 275 $ 10000 a 64 Print Conversion rate Received on account entries Procedure Amount (max. 8 digits) Example a Å É k CHK2 CHK5 r ® , thru , thru or CH1 thru CH9 f A customer whose reference number is 12345 tenders $48.00 by check for received on account. Key operation Print 12345 = 4800 r #/ TM k Paid out entries Procedure Amount (max. 8 digits) Example a Å É k CHK2 CHK5 p π , thru , thru or CH1 thru CH9 f You pay $30.00 by check to a vendor whose code number is 6789. Key operation Print 6789 = 3000 p #/ TM k No sale (exchange) Simply press the n key without any entry. The drawer will open and the printer will print “NO SALE” on both the journal and the receipt. If your machine is preset to print a non-add code number before pressing the n key, a no sale entry is achieved with a non-add code number printed. 65 Cashing a check Enter the check amount, then press a check key (k, CHK1 thru CHK5 ). Procedure Non-add code number Example #/ TM Check amount k , CHK2 thru CHK5 Cashing a check of a $30.00 amount Key operation Print 6789 = 3000 k #/ TM Bottle return This function is used to handle the payment (paid out) for returned empty bottles or cans. Example You pay for ten 15¢ returned empty bottles. (This example presupposes that dept. 10 has been programmed as bottle return department.) Key operation Print 10 @ 15 10 a 9 Automatic sequencing key entries You can achieve many different key sequences automatically with a single key depression by using an automatic sequencing key (~ thru 10 ). Example Performing the transaction “Selling a $5.00 item (dept. 7) for cash” programmed for the ¡ (¡ = 500 7 a) Key operation ¡ 66 Print 10 WASTE mode This mode is used to throw away an article which has already been prepared and is no longer serviceable. Procedure WASTE [Item entries ] WASTE WASTE mode Example Wasting 10 PLU 35 items Key operation Print WASTE 10 @ 35 PLU/ UPC WASTE Note • PLU/UPC entries are only allowed in the WASTE mode, and direct and indirect void operations are also allowed in this mode. • When a WASTE mode transaction is finalized, the drawer does not open. • The consecutive number is incremented every WASTE mode transaction. • When the WASTE mode is activated by pressing the WASTE key, the mode caption “WAST” is displayed. 67 CORRECTION 1 Correction of the last entry (direct void) If you make an incorrect entry relating to a department, PLU/subdepartment, UPC, percentage (% through •), deduction (- through ≠) or refund, you can correct this entry by pressing the v key immediately after the incorrect entry. Example Key operation Print 1250 6 v PLU/ 2P UPC v PLU/ 5012345678900 P UPC v 600 8 § v 328 9 28 - 9 v 250 Ï 8 v a 2 Correction of the next-to-last or earlier entries (indirect void) With the v key, you can void any incorrect department, PLU/subdepartment, UPC or item refund entry made during a transaction if you find it before finalizing the transaction (e.g. pressing the a key). This function is applicable to department, PLU/subdepartment, UPC and item refund entries only. For the operation, press the v key just before you press a department key, à key, direct PLU key, just before you scan a UPC code. For the refund indirect void, press the v key after you press the Ï key. Example Key operation Print 1310 6 1755 7 PLU/ 10 P UPC ô PLU/ 58 P UPC 825 7 PLU/ 5012345678900 P UPC 1310 v 6 vô PLU/ 58 v P UPC PLU/ 5012345678900 v P UPC a 68 PLU/ UPC key or 3 Subtotal void You can void an entire transaction. Once the subtotal void is executed, the transaction is aborted and the register issues a receipt. Example Key operation Print 1310 1 1755 6 PLU/ 10 P UPC PLU/ 35 P UPC Subtotal void ı v ı Correction of incorrect entries not handled by the direct or indirect void 4 function Any errors found after the entry of a transaction has been completed or during an amount tendered entry, cannot be voided. These errors must be handled by the manager. The following steps should be observed: 1. 2. 3. If you are in the middle of making an amount tendered entry, you must first finalize the transaction before making corrections. Try to make correct entries from the beginning. Hand the incorrect receipt to your manager for its cancellation. 69 CORRECTION AFTER FINALIZING A TRANSACTION (AFTER GENERATING A RECEIPT) When you need to void incorrect entries that are found after finalizing a transaction or cannot be corrected by direct or indirect void, follow this procedure in the MGR mode. 1. 2. 3. Turn the mode switch to the MGR position. Press the v key to put your register in the VOID mode. Repeat the entries that are recorded on an incorrect receipt. (All data for the incorrect receipt are removed from register memory; the voided amounts are added to the void register totalizer.) Incorrect receipt Note 70 Cancellation receipt Your machine leaves the VOID mode whenever a transaction is canceled (i.e. finalized in the VOID mode.) To void additional transactions repeat steps 2. and 3. above. OVERRIDE ENTRIES Programmed limits (such as maximum amounts) for functions can be overridden by making the entry in the MGR mode. Procedure 1. 2. Turn the mode switch to the MGR position. Make the override entry. Example Selling a $15.00 item (dept. 2) for cash and subtracting the coupon amount $2.50 from the sale amount (This example presumes that the register has been programmed not to allow coupon entries over $2.00.) Key operation Print 1500 2 REG-mode250 –2 ...Error entries c Turn the mode switch to the MGR position. 250 – Return the mode switch to the REG position. a 71 OVERLAPPED CASHIER/SERVER ENTRY This function allows you to switch from one cashier/server to another interrupting the first cashier/server’s entry. The second cashier/server can make a sales entry, then the first cashier/server may continue. Example Cashier 1: Entry started Cashier 2: Cashier/server change (1 to 2), interruption initiated Cashier 2: Transaction finished (2) Cashier 1: Cashier/server change (2 to 1), entry restart Note • The overlapped cashier/server entry is not available while the tendering sale. • If any cashier/server is still making an entry (or has not finalized the transaction yet), the machine does not run in any mode other than REG and MGR and X/Z reports can not be performed. The error message “SERVER ERR.” and the corresponding cashier/server code(s) are displayed at this time. Key operation Comments 1. Cashier/server 1 is assigned. The entry by cashier/server 1 is started. (1‹) 100 1 360 3 3 2. Cashier/server 2 is assigned. 2‹ 3@ 150 2 a The entry by cashier/server 2 is started. (The entry by cashier/server 1 is interrupted.) The transaction by cashier/server 2 is finalized. 3. Cashier/server 1 is assigned. 1‹ 100 1 360 3 a 72 The entry by cashier/server 1 is restarted. The transaction by cashier/server 1 is finalized. SPECIAL PRINTING FUNCTIONS 1 Copy receipt printing If your customer wants a receipt after you have finalized a transaction with the receipt ON-OFF function in the “OFF” status (no receipting), press the q key. This will make a copy receipt. Your register can also print a copy receipt when the receipt ON-OFF function is in the “ON” status. Note Pressing the q key in the OP X/Z mode before registration toggles the status “ON” and “OFF”. Example Printing a copy receipt after making the entries shown below with the receipt ON-OFF function in the “OFF” status Key operation 850 2 3@ 150 1 a For receipting→ Print Print on the journal q Print on the receipt When the receipt ON-OFF function is in the “ON” status and you press the q key to make a second copy When the receipt ON-OFF function is in the ON status, the COPY symbol will be printed on the receipt. 73 2 Validation printing function (Slip printer) Your register can perform validation printing when it is connected with the slip printer. For the details about the slip printer, contact your authorized SHARP dealer. 1. Set a validation slip to the slip printer. 2. Press the ∏ key. The validation printing will start. Note When you make an entry for which compulsory validation printing can be overridden by performing the following operation. If you need this function, Contact your authorized SHARP dealer. 1. 2. Move the mode key to the MGR position. . ∏ 3 Bill printing This function is used for issuing bills to customers/guests. Your register can print bills on a slip printer or receipts on the register depending on the programming. You can issue bills when GLU/PBLU/Manual PB/CB entries are done only, for every entry or when a media key is pressed. For this selection, please consult your authorized SHARP dealer. When bill printing is compulsory, the register will print a bill automatically in case it is to be printed on receipts and when a slip is inserted in case it is to be on a slip printer. When bill printing is non-compulsory, use the following procedure to print a bill. Bill on receipts Bill on the slip (auto feed) Ω XX No. of lines of slip feed Note This function is available immediately after the finalization of transaction (including after pressing the S or the f key). 4 Printing of the employee’s arrival and departure times (Slip printer) Your register can print the employee’s arrival and departure time when it is connected with the slip printer. For the details for connecting a slip printer, please contact your authorized SHARP dealer. For printing of the arrival and departure times, you must be in the OP X/Z mode. Printing of arrival time 1 ∏ Printing of departure time 2 74 ∏ 5 Printing of header and footer graphic logos As an optional setting, your register can print a graphic logo on the top of each receipt (header graphic logo). If preset to do so, a graphic logo can be printed on the bottom of each receipt (footer graphic logo) with the job code #2616. You can also print the graphic logos with the combination of 3-line header logo message or 3-line footer logo message. Printing only logo messages without the graphic logo is possible. Please consult your dealer when you want to change the setting. • Sample receipt with a header graphic logo and a footer graphic logo Header graphic logo Footer graphic logo 6 Remote printer send function This function enables a partial order to be sent to the kitchen for preparation while the remaining order is still being placed. Example Item entry RP SEND Data transfer to the remote printer Remaining items will be sent to the remote printer when the transaction is finalized. When this function is used, the subtotal void operation is not allowed. 75 TIME DISPLAY AND AUTOMATIC UPDATING OF THE DATE 1 Time display When you need the time displayed, turn the mode switch to the OP X/Z position after the preceding transaction or operation is finalized. #/ You can also display the time by pressing the TM key in the REG or MGR mode. The time display disappears as soon as you press the c key in the REG or MGR mode or begin the subsequent entry. Sample display of 10:25 AM Date Time 2 Automatic updating of the date Once the internal clock unit is started at the correct time, it continues to run as long as the built-in battery is charged, and updates the date (month, day, year) automatically. 76 FOR THE MANAGER PRIOR TO PROGRAMMING 1 Programming keyboard layout When you are in the PGM1 or PGM2 mode, the keyboard layout will be set to one of the programming layouts as shown below. For ER-A520 (NUM) RECEIPT JOURNAL ( ) ( ) ( ) ( ) @ ( ) FOR ( ) PO 7 8 4 (%) ( ) 5 2 1 0 (SHIFT) (SHIFT-2) (SPACE) æ BACK Æ SPACE cl (DC) CL ” 9 ’ 6 : 3 + A ” # G B < > ? Z W Ç N I D Y V R = ) ! . M H - ( Q L , ; X U / SBTL S Pt £ E J O T } [ ] ) & % P K @ C 00 $ F ( CA/AT/NS For ER-A530 ? < > 6 ( 13 ) =27 ➞ ▲ ’ ” ! @ # $ % ^ L2 DEPT & # 1 œ 2 3 4 5 6 7 CR2 85 912 019 -26 Q AUTO W E R T Y CR1 U I 4 O11 P18 –25 A S D F G H J K3 L10 ; 17 : 7 8 9 Z” X C V B N M2 , . – 4 5 6 1 2 3 0 00 +33 @ (SHIFT) (DC) (SPACE) (SPACE) (SPACE) (SPACE) (SPACE) Note Î: Ó: é: BACK (SPACE ) ➞ ? { ▲ Ñ ➞ ➞ ” RECEIPT JOURNAL CL FOR SBTL CA/AT • The programming keyboard sheet is transparent, allowing placement over the standard keyboard sheet. • The shaded area contains the character keys which are used for programming characters. Used to enter the double-size character. Used to change a lower-case letter/upper-case letter. Used to select a symbol. (ER-A520 only) cl æ Æ To enter the letter “ cl cl ”, press é cl æ Æ é To enter the upper-case letter “Æ Æ”, press To enter the lower-case letter “æ æ”, press / : Used to back up the cursor for deleting. (NUM) : Used to enter a numeric character. (ER-A520 only) cl æ Æ Ó æ Æ cl cl cl æ Æ æ Æ cl æ Æ Ó : Used to enter a space. 77 2 How to program alphanumeric characters You can program alphanumeric characters for departments, PLUs, UPCs, functions, etc. while in the character entry mode. There are two ways for programming characters: using character keys on the keyboard and entering character codes with the numeric keys on the keyboard. Using character keys on the keyboard (keys on the shaded area) Enter a character according to the position in the programming keyboard layout. Entering alphanumeric characters To enter a character, simply press a corresponding character key. ˆ In case of ER-A520, “( )”, “( )”, “( )”, “ ( )”, “( )”, “( )”, “( ° )”, and “( )” keys can be used in combination ˆ ¨ ` ´ ´´ ˜ with a character key. If the combination is unavailable, only a character key is entered. [Ex.] “Å” : ➞ (°) ➞ A To enter a numeric character: (ER-A520) Press (NUM) key and enter a number by ten keys (0 – 9). (NUM) ➞ 135 ➞ (NUM) [Ex.] Entering the character “135” : (ER-A530) Simply press a corresponding numeric key in the shaded area. To enter a space, press the / key. Entering double-size characters Î : This key toggles the double-size character mode and normal-size character mode. The default is the normal-size character mode. The double-size character is displayed with the letter “=” (ex. =S). [Ex.] To program the name “SHARP” in double size : Î ➞ SHARP ➞ Î Entering lower-case letters Ó : You can enter a lower-case letter by using this key. Press Ó key just before you enter the lower-case letter. This key also allows you to enter the characters/symbols shown at the upper right of keys. [Ex.] To program the name “Sharp” : ➞ S ➞ Ó ➞ harp ➞ Ó Entering symbols shown at the upper left of keys (ER-A520 only) é: You can enter symbols by using this key. Press é key just before you enter the symbol. [Ex.] To program the symbol “ cl cl ” : ➞ é ➞ cl ➞ é ➞ cl Editing text You can edit the text you have entered by deleting characters. : Backs up the cursor for deleting the character or figure at the left of the cursor. Entering character codes Numerals, letters and symbols are programmable by entering the º key and character codes. See the “Alphanumeric character code table” on the next page. In this way, you can program characters other than the characters shown in the programming keyboard layout. XXX ➞ º Note XXX: Character code (3 digits) • Double-size characters can be made by entering the character code 253. [Ex.] To program the name “SHARP” in double size 253 º (DC) 78 083 S º 072 H º 065 A º 082 º R 080 º P Alphanumeric character code table Code Character 091 Ä 092 Ö 093 Ü 094 ^ 095 _ 096 ’ 097 a 098 b 099 c 100 d 101 e 102 f 103 g 104 h 105 i 106 j 107 k 108 l 109 m 110 n 111 o 112 p 113 q 114 r 115 s 116 t 117 u 118 v 119 w 120 x 121 y 122 z 123 { 124 | 125 } 126 ß 127 ¢ 128 !! 129 1 130 2 131 3 132 4 1/2 133 F/T 134 ← 135 Code Character 136 → 137 138 139 140 141 F 142 T ↓ 143 ç 144 ° 145 ¿ 146 Ù 147 à 148 Æ 149 ø 150 Å 151 152 ¤ é 153 è 154 Pt 155 i 156 Ñ 157 ò 158 £ 159 ¥ 160 161 ° 162 163 164 . 165 Á 177 Í 178 A 180 a 181 E 182 e 183 I 184 i 185 186 U u 187 N 188 . n. 189 190 C 191 S C 192 . ▲ Code Character 046 . 047 / 048 0 049 1 050 2 051 3 052 4 053 5 054 6 055 7 056 8 057 9 058 : 059 ; 060 < 061 = 062 > 063 ? 064 @ 065 A 066 B 067 C 068 D 069 E 070 F 071 G 072 H 073 I 074 J 075 K 076 L 077 M 078 N 079 O 080 P 081 Q 082 R 083 S 084 T 085 U 086 V 087 W 088 X 089 Y 090 Z ▲ Code Character 001 á 002 â 003 ê 004 î 005 ì 006 í 007 ô 008 ó 009 û 010 ú 011 œ 012 u ´´ 013 ú 014 o ´´ 015 ó 016 017 018 019 ¨ 020 021 022 023 024 025 026 027 ´´ 028 U 029 Ú ´´ 030 O 031 Ó 032 (space) 033 ! 034 ” 035 # 036 $ 037 % 038 & 039 ’ 040 ( 041 ) 042 043 + 044 , 045 - Code Character . 193 .I 194 G 195 S. 196 G .. 197 g 198 K. 199 k. L 200 l 201 202 Z 203 D 204 d 205 C 206 c 207 P 208 209 e 210 s 211 c 212 z 213 y 214 . u 215 n 216 217 218 r 219 224 § 225 Ø 226 227 ↑ 228 ] 229 [ 230 231 ” ä 232 ö 233 ü 234 æ 235 å 236 É 237 ñ 238 *(DC) 253 ✱ ✱ (DC) : Double-size character code : The shaded character cannot be displayed (will be displayed as space). Note The character “ !! ” (code: 128) is displayed as “ ! ”. 79 PROGRAMMING This chapter illustrates how to program your cash register. Basic instructions All the programming items can be programmed by the Job-Code-Based Programming described later. Also your machine allows you to program some items using the Direct Programming, which does not require you to enter the job code. However, object keys (shown below) must be allocated on the keyboard. For the keys not allocated on the keyboard, you cannot use the direct programming. Job-Code-Based Programming Simplified procedure : XXX (Job code) @ . Data entry Ç Direct Programming Sample procedure : Data entry – Ç (Object key) Preparations for programming 1. 2. 3. 4. Plug your machine into a standard grounded AC outlet. Turn the mode switch to the PGM1 or PGM2 position. To set the mode switch to the PGM1 position, use the manager or submanager key; and to set it to the PGM2 position, use the manager key. Check to see whether both journal and receipt rolls are present in the machine. If they are missing, install journal and receipt paper rolls correctly referring to the procedure in “4. Installing and removing the paper roll” under “OPERATOR MAINTENANCE”. Program the necessary items into your machine. Direct Programming 1 Setting the date and time Date PGM 1 PGM 2 Enter the month (one or two digits), day (two digits), and year (four digits : 2000 – 2099) in this sequence. Procedure XXXXXXXX Date (seven or eight digits) #/ TM Example Key operation Print 08262004 = #/ TM Date 80 Time PGM 1 PGM 2 Set the time using the military time (24-hour) system. For example, when the time is set to 2:30 AM, enter 230; and when it is set to 2:30 PM, enter 1430. The time will be printed and displayed using a real-time system. Once you set the time, the internal clock unit will continue to run as long as the built-in battery is alive and update the date (day, month, year) properly. Procedure #/ TM XXXX Time (max. four digits) Example Key operation Print 1430 = #/ TM Time 2 Programming for departments Your machine is equipped with 20 (ER-A520)/10 (ER-A530) standard departments and a maximum of 99 departments. Your machine allows you to perform the following programming for each department. Unit price PGM 1 PGM 2 Procedure To program any dept. To program zero 1 Unit price (max. 6 digits) Dept. code (1 — 99) à 99 · Unit price (max. 6 digits) Ç ı To program zero To program the next sequential dept. Example Key operation Print 1000 1 Ç Unit price 81 Functional selection PGM 2 Procedure To program any dept. To set all zeros @ *1 ABCDEFGHIJKLMNOP Dept. code (1 — 99) à 1 99 · *1 ABCDEFGHIJKLMNOP Ç @ To set all zeros To program the next sequential dept. *1 Item: A Group number B Commission group number C Sign (plus/minus) D E F G H I J K L M N O P 82 Selection: Entry: 0 thru 9 (0: Non group) 0 thru 9 (0: Non commission) Plus 0 Minus 1 Food stamp status Ineligible 0 Eligible 1 Tax 4 status Non-taxable 0 Taxable 1 Tax 3 status Non-taxable 0 Taxable 1 Tax 2 status Non-taxable 0 Taxable 1 Tax 1 status Non-taxable 0 Taxable 1 Item validation printing Non-compulsory 0 Compulsory 1 Tare table number 0 thru 9 (0: not used) Scale entry Inhibit 0 Enable 1 Compulsory 2 Registration type Normal 0 SICS (Single Item Cash Sale) 1 SIF (Single Item Finalization) 2 Department type Normal department 0 Hash department 1 Bottle return department 2 Gas department 3 Type of unit price entry Inhibit department key 0 Open only 1 Preset only 2 Open and preset 3 Significant digit for HALO 1 thru 9 Number of zeros to follow the significant digit for HALO 0 thru 7 Note Group number You can assign a department to a maximum of nine groups. This programming enables you to take group sales reports. Commission group number A commission group number (0–9, 0: non commission) can be assigned to each department. Sign (plus/minus) • Assign a plus sign to departments for normal sales transactions. • Assign a minus sign to departments for minus transactions. Food stamp status • Assign a food stamp status (food stamp eligible or food stamp ineligible) to each department. Tax status (taxable 1 thru 4/non-taxable) • When an entry of a taxable department is made in a transaction, tax is automatically computed according to the associated tax table or rate. • Tax 4 is prohibited if you use the food stamp function. Item validation printing If item entries must be validated, program corresponding departments for compulsory validation printing. Tare table number Tare table number associated with scale entry (1 thru 9). Scale entry Program a department for scale entry when your store requires items to be sold by weight and are placed on a scale connected to the register. Registration type • If an entry of a department programmed for SICS is made first, the sale will be finalized as soon as the department key is pressed. If the entry is made after entering a department not programmed for SICS, the sale will not be finalized until the Ç key is pressed. • Whenever a sale is made to a department programmed for SIF, the sale is finalized as soon as the department key is pressed. Department type You may program each department as one of the following three types. • Normal department • Hash department A hash department is used to enter the amount of a special “sale”, such as a gift certificate sale or for the receipt of payment for utility bills, theatre tickets, etc., i.e. “non-sales” registrations. Any amounts entered in this department are not added to the grand total except tax amounts. • Bottle Return (BR) • Gas department The gas department enables you calculate the quantity of gas sold in gallon by using a preset unit price when the sale amount of gas is entered. (quantity of gas = sales amount entered / preset unit price) Also gas discount can be automatically applied to the sales. (discount amount = total amount of gas x reduced unit price for each media; cash/check/charge) Type of unit price entry You may select one of the following four types of unit price entry for each department. • Open and preset • Preset only • Open only • Inhibit department key HALO (High Amount Lockout) You can set an upper limit amount (HALO) for each department. The limit is affective for the REG mode operations and can be overridden in the MGR mode. • “OP” is the same as O × 10P For example, presetting 14 ($100.00) here means that amount entries of up to $100.00 are allowed in the REG mode. When you preset 17, the upper limit amount is 99999.99. 83 Example Key operation Print 1000000100000317 @ 1 Ç Taxable1 Commission group no. HALO Group no. IJKLMN Food stampstatus F:Eligible (None):Ineligible 3 PLU/UPC programming Your machine is equipped with 2000 standard PLU/UPC codes. Your machine allows you to perform the following programming for each PLU/UPC. Note • Please note that the price lookup/subdepartment/UPC key (P for ER-A520) is shown as PLU/ UPC . • To review the UPC codes available to this register, please refer to the chapter 13 in “Universal Product Code(UPC) or European Article Number(EAN)”. • Ä in Procedures indicates that you scan a barcode. Unit price PGM 1 PGM 2 Procedure To program any PLU/UPC l Level no. (1 to 5) 5 Ä To keep current setting Direct PLU key Unit price 1 (max. 6 digits) ı Ç ä PLU code (max. 5 digits) PLU/ UPC * To program unit price 2 thru 6 (only when price shift function is allowed.) To program for the following PLU/UPC UPC code (6 to 13 digits) * In case that price shift function is allowed, the register prompts to enter a unit price for the following level by displaying “P2” thru “P6” on the display, and when a unit price of level 6 is entered, the register goes to the status for programming the following PLU/UPC. When you press the Ç on the way of programming multiple prices for a PLU/UPC code, prices for the remained levels are kept unchanged. In case that single price entry is allowed for a PLU/UPC code, the register goes to the status for programming the following PLU/UPC. Example Key operation Print PLU/ UPC 1000 ı 1P Ç Unit price 84 (In case of single price entry) Functional selection PGM 2 Procedure To program any PLU/UPC Ä l Level no. (1 to 5) Direct PLU key 5 ä To program zero *1 ABCDEFGHIJ Ç @ To program for the following PLU/UPC PLU/ UPC PLU code (max. 5 digits) UPC code (6 to 13 digits) *1 Item: A Commission group number B Sign (plus/minus) C Food stamp status D Tax 4 status E Tax 3 status F Tax 2 status G Tax 1 status H I Tare table number Scale entry J Type of unit price entry Note Selection: Plus Minus Ineligible Eligible Non-taxable Taxable Non-taxable Taxable Non-taxable Taxable Non-taxable Taxable Inhibit Enable Compulsory Prohibit mode Open price only Preset price only Open price and preset price Delete mode Entry: 0 thru 9 (0: Non commission) 0 1 0 1 0 1 0 1 0 1 0 1 0 thru 9 (0: Not used) 0 1 2 0 1 2 3 4 Commission group number A commission group number (0–9, 0: non commission) can be assigned to each department. Sign (plus/minus) The function of every PLU/UPC varies according to the combination of its sign and the sign of its associated department as follows: Sign Department + – + – PLU/UPC + – – + Function of PLU/UPC Serves as a normal plus PLU/UPC Serves as a normal minus PLU/UPC Accepts store coupon entries, but not split-pricing entries Not valid; not accepted Food stamp status • Assign a food stamp status (food stamp eligible or food stamp ineligible) to each PLU/UPC. 85 Tax status (taxable 1 thru 4/non-taxable) • When an entry of a taxable PLU/UPC is made in a transaction, tax is automatically computed according to the associated tax table or rate. • Tax 4 is prohibited if you use the food stamp function. Tare table number Tare table number associated with scale entry (1 thru 9). Scale entry Program a PLU/UPC for scale entry when your store requires items to be sold by weight and are placed on a scale connected to the register. Type of unit price entry You may select one of the following four types of unit price entry for each PLU/UPC. • Open price and preset price (for only PLU) • Preset price only • Open price only (for only PLU) • Prohibit mode: Prohibits the entry of any assigned PLU/UPC code. • Delete mode: Deletes data programmed for each PLU/UPC. Example Key operation Print PLU/ UPC 0000001003 @ 1P Ç Taxable1 Commission group no. (HIJ) Associated department PGM 1 PGM 2 Procedure To program any PLU/UPC To delete the entered PLU/UPC v Ä l Level no. (1 to 5) Direct PLU key 5 Associated department code (1 – 99) ä 1 PLU code (max. 5 digits) PLU/ UPC à Ç 99 · To program for the following PLU/UPC UPC code (6 to 13 digits) Example Key operation Print PLU/ 1P UPC 1 Ç 86 Associated dept. code 4 Programming for discount keys (-) Discount amount PGM 1 PGM 2 Procedure To program zero - ± Discount amount (max. 6 digits) Ç Example Key operation Print 1000 - Ç Discount amount Functional programming PGM 2 Procedure To program zero *ABCDEFGHI @ - ± Ç To program any coupon function * Item: Selection: A Food stamp status Ineligible Eligible Non-taxable Taxable Non-taxable Taxable Non-taxable Taxable Non-taxable Taxable Plus Minus B Tax 4 status C Tax 3 status D Tax 2 status E Tax 1 status F Sign (+/-) G Vendor/store coupon selection H I Significant digit for HALO Number of zeros to follow the significant digit for HALO Vendor coupon (subtotal _) Store coupon (item _) Entry: 0 1 0 1 0 1 0 1 0 1 0 1 0 1 1 thru 9 0 thru 7 87 Note Tax status (taxable 1 thru 4/non-taxable) Tax 4 is prohibited if you use the food stamp function. HALO (High amount lockout) “HI” is the same as H x 10 I. For example, presetting 14 ($100.00) here means that amount entries of up to $100.00 are allowed in the REG mode. When you preset 17, however, the upper limit amount is 99999.99. When you preset 00, the open amount entry is prohibited. Example Key operation Print 000011013 @ - Ç HALO Taxable 1 Food stamp status F:Eligible (None):Ineligible Subtotal _ 5 Programming for percent keys (%) Percent rate PGM 1 PGM 2 Procedure To program zero *Rate ) (¡) ∞ Ç * Rate: Percent rate: 0.00 – 100.00 Note You must use a decimal point key when setting percentage rates that are fractional. Example Key operation Print 10 . 25 % Ç Percent rate 88 Functional programming PGM 2 Procedure To program zero @ *ABCDEFGHIJ ) (¡) ∞ * Item: A Type of amount entry B Food stamp status C Tax 4 status D Tax 3 status E Tax 2 status F Tax 1 status G Sign (+/-) H item%/subtotal% selection I J Always enter 0. Always enter 0. Note Ç Selection: Inhibit percent key Open only Preset only Open and preset Ineligible Eligible Non-taxable Taxable Non-taxable Taxable Non-taxable Taxable Non-taxable Taxable Plus Minus Entry: 0 1 2 3 0 1 0 1 0 1 0 1 0 1 0 1 Subtotal % Item % 0 1 0 0 Tax status (taxable 1 thru 4/non-taxable) Tax 4 is prohibited if you use the food stamp function. Example Key operation Print 3000011000 @ % Ç Taxable 1 Subtotal % 89 6 Programming for conversion keys (ç) Currency conversion rate PGM 1 PGM 2 Procedure To program zero *Conversion rate ç # Ç * Conversion rate: 0.0000 – 9999.9999 Note You must use a decimal point key when setting conversion rates that are fractional. Example Key operation Print 0 . 8063 ç Ç 7 Programming for the r, p, and † keys High amount lockout (HALO) PGM 2 The HALO limit effects REG mode operations but can be overridden in the MGR mode. The HALO limit is represented by two figures as follows: Procedure AB r A p π † or To program zero @ or Ç (Only for manual entry) “AB” is the same as A × 10B. A: Significant digit (0 through 9) B: Number of zeros to follow significant digit: (for RA or PO: 0 thru 9), (for manual tax: 0 thru 7) Example Key operation Print 13 @ r Ç 90 CA , ', and k keys 8 Programming for the Ç, Å High amount lockout (HALO) and functional selection PGM 2 Procedure h CH9 k CHK5 Å É s To program zero *ABCDEFGHIJKL @ (For Ç * Item: A key) Selection: GLU/PBLU/Manual PB/CB entry Enable Inhibit Compulsory Enable Disable No Yes Non-compulsory Compulsory No Yes Non-compulsory Compulsory Enable Disable Non-compulsory Compulsory Yes No Optional amount tendered for cash or check Inhibit amount tendered for charge Compulsory amount tendered B Short amount tender entry C Retention of closed GLU/PBLU file D Bill (slip) printing E Footer printing on receipt F Non-add code entry G Change enable (over tender enable) H Validation printing I Drawer opening J Amount tendered operation K L Significant digit for HALO Number of zeros to follow the significant digit for HALO Note Ç Entry: 0 1 2 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 0 1 0 thru 9 0 thru 8 HALO (High amount lockout) “KL” is the same as K × 10 L. For example, presetting 13 ($10.00) here means that amount entries of up to $10.00 are allowed in the REG mode. When you preset 18, however, the upper limit amount is 999999.99. 91 Example Key operation Print 000000000015 @ ) Ç HALO A thru J 92 9 Programming for the automatic tax calculation function Your machine has an automatic tax calculation feature which allows you to program four tax tables to avoid calculating incorrect tax amounts. Automatic tax calculations require you to program, in addition to the tax table, the tax status of each pertinent department, PLU/UPC, and function key. The tax table (applicable to the add-on tax) PGM 2 Sample tax table New Jersey tax table: 6% Range of sales amount Taxes .00 .01 Minimum breakpoint .01 T .11 Q Maximum breakpoint A: Difference between the minimum breakpoint and the next one (¢) to .10 – to .22 10 (0.11 - 0.01) .02 .23 to .38 12 (0.23 - 0.11) .03 .39 to .56 16 (0.39 - 0.23) .04 .57 to .72 18 (0.57 - 0.39) .05 .73 to .88 16 (0.73 - 0.57) to 1.10 16 (0.89 - 0.73) to 1.22 22 (1.11 - 0.89) .06 .89 .07 1.11 .08 1.23 to 1.38 12 (1.23 - 1.11) .09 1.39 to 1.56 16 (1.39 - 1.23) .10 1.57 to 1.72 18 (1.57 - 1.39) .11 1.73 to 1.88 16 (1.73 - 1.57) .12 1.89 to 2.10 16 (1.89 - 1.73) .13 2.11 to 2.22 22 (2.11 - 1.89) M1 M2 B: Non-cyclic C: Cyclic-1 D: Cyclic-2 To program a tax table, first make a table like the right table shown above. From the tax table, calculate the differences between a minimum break point and the next one (A). Then, from the differences, find irregular cycles (B) and regular cycles (C and D). These cycles will show you the following items necessary to program the tax table: T: Q: M1: M2: M: The tax amount collected on the minimum taxable amount (Q) The minimum taxable amount The maximum value of the minimum breakpoint on a regular cycle (C). We call this point “MAX point.” The maximum value of the minimum breakpoint on a regular cycle (D). We call this point “MAX point.” Range of the minimum breakpoint on a regular cycle: difference between Q and M1 or between M1 and M2 93 Procedure One- or two-*1 digit number † T max. three digits @ @ @ *2 Rate max. six digits (0.0001 - 99.9999%) @ Q max. five digits M max. four digits Minimum breakpoint max. five digits @ @ Ç Repeat until the MAX point is entered. To delete a tax table, use the following sequence: One- or two-*1 digit number † @ @ *2 Rate max. six digits (0.0001 - 99.9999%) M max. four digits @ t *1 First figure: The first figure to be entered depends upon whether the difference between a minimum breakpoint to be entered and the preceding minimum breakpoint is not less than $1.00 or more than 99¢. When the difference is not less than $1.00, enter “1,” and when it is not more than 99¢, enter “0” or nothing. Second figure: The second figure depends upon whether your tax table is to be programmed as tax table 1, 2, 3 or 4. When your tax table is to be programmed as tax table 1, enter “1”; when it is to be programmed as tax table 2, enter “2”; when it is to be programmed as tax table 3, enter “3”; and when it is to be programmed as tax table 4, enter “4”. *2 If the rate is fractional (e.g. 4-3/8%), then the fractional portion (3/8) would be converted to its decimal equivalent (i.e. .375) and the resulting rate of 4.375 would be entered. Note that the nominal rate (R) is generally indicated on the tax table. Note If you make an incorrect entry before entering the M in programming a tax table, cancel it with the c key; and if you make an error after entering the M, cancel it with the ı key. Then program again from the beginning correctly. • Limitations to the entry of minimum breakpoints Your register can support a tax table consisting of no more than 72 breakpoints. (The number of breakpoints is 36 maximum when the breakpoint difference is $1.00 or more.) If the number of breakpoints exceeds the register’s table capacity, then the manual entry approach should be used. Example Programming the sample tax table shown on the previous page as tax table 1 Key operation Print † Tax rate M T Q → → → → The first cyclic portion M1 (MAX point)→ 1@ 6@ 100 @ 1@ 11 @ 23 @ 39 @ 57 @ 73 @ 89 @ 111 @ a Note 94 You do not need to enter the trailing zeros of the tax rate (after the decimal point) but you do need to enter the decimal point for fractions. • If the tax is not provided for every cent, modify the tax table by setting the tax for every cent in the following way. When setting the tax, consider the minimum breakpoint corresponding to unprovided tax to be the same as the one corresponding to the tax provided on a large amount. Sample tax table Example 8% Tax .00 .01 .02 .03 .04 .06 .09 .10 .11 .12 .14 .17 Minimum breakpoint .01 .11 .26 .47 .68 .89 1.11 1.26 1.47 1.68 1.89 2.11 Modification of the left tax table Minimum breakpoint Tax .00 .01 .02 .03 .04 .05 .06 .07 .08 .09 .10 .11 .12 .13 .14 .15 .16 .17 T .01 .11 .26 .47 .68 .89 .89 1.11 1.11 1.11 1.26 1.47 1.68 1.89 1.89 2.11 2.11 2.11 Q M1 M2 Breakpoint difference (¢) 1 10 (0.11-0.01) 15 (0.26-0.11) 21 (0.47-0.26) 21 (0.68-0.47) 21 (0.89-0.68) 0 (0.89-0.89) 22 (1.11-0.89) 0 (1.11-1.11) 0 (1.11-1.11) 15 (1.26-1.11) 21 (1.47-1.26) 21 (1.68-1.47) 21 (1.89-1.68) 0 (1.89-1.89) 22 (2.11-1.89) 0 (2.11-2.11) 0 (2.11-2.11) B: Non-cyclic C: Cyclic-1 D: Cyclic-2 From the modified tax table above; Rate = 8(%), T = $0.01 = 1¢, Q = $0.11 = 11¢, M1 = 1.11, M2 = 2.11, M = 100 95 Job-Code-Based Programming This section illustrates how to program items using job codes. Using job codes allows you to program a wide variety of items in comparison with direct programming. Start this programming by entering a corresponding job code as shown below. 2110 . @ All the items which can be programmed by the job-code-based programming are listed on this page and the following, and those which can also be programmed by the direct programming are marked with the symbol “ Direct ” that follows job codes. 1 Setting the date and time Setting the date PGM 2 2610 Direct Enter the month (one or two digits), day (two digits), and year (four digits: 2000 – 2099) in this sequence. Procedure 2610 . @ Example Date (seven or eight digits) Ç Key operation Print 2610 . @ 08262004 Ç Date Setting the time PGM 2 2611 Direct Set the time using the military time (24-hour) system. For example, when the time is set to 2:30 AM, enter 230; and when it is set to 2:30 PM, enter 1430. The time is printed and displayed on the real time system. Procedure 2611 . Example @ Time (max. four digits) Key operation Ç Print 2611 . @ 1430 Ç Time 96 2 Setting the register and consecutive numbers Setting the register number PGM 2 2612 When your store has two or more registers, it is practical to set separate register numbers for their identification. You may set them with a maximum of six digits. Procedure To set the register number “0” 2612 . Example @ Register number (one to six digits) Ç To set the register number as “123456” Key operation Print 2612 . @ 123456 Ç Register number Setting the consecutive number PGM 2 2613 The consecutive number is increased by one each time a receipt is issued. Enter a number (one to four digits) that is one less than the desired starting number. Procedure To begin the count from 0001 2613 . Example @ A number (one to four digits) that is one less than the desired starting number Ç Setting the count start number as “1001” Key operation Print 2613 . @ 1000 Ç Consecutive number 97 3 Programming for the automatic tax calculation function Your machine has an automatic tax calculation feature which allows you to program four tax tables or rates to avoid calculating incorrect tax amounts. Automatic tax calculations require you to program, in addition to the tax table and rate, the tax status of each pertinent department, PLU/UPC, and function key. The tax table (applicable to the add-on tax) PGM 2 2710 Direct Sample tax table New Jersey tax table: 6% Range of sales amount Taxes .00 .01 Minimum breakpoint .01 T .11 Q Maximum breakpoint A: Difference between the minimum breakpoint and the next one (¢) to .10 – to .22 10 (0.11 - 0.01) .02 .23 to .38 12 (0.23 - 0.11) .03 .39 to .56 16 (0.39 - 0.23) .04 .57 to .72 18 (0.57 - 0.39) .05 .73 to .88 16 (0.73 - 0.57) to 1.10 16 (0.89 - 0.73) to 1.22 22 (1.11 - 0.89) .06 .89 .07 1.11 .08 1.23 to 1.38 12 (1.23 - 1.11) .09 1.39 to 1.56 16 (1.39 - 1.23) .10 1.57 to 1.72 18 (1.57 - 1.39) .11 1.73 to 1.88 16 (1.73 - 1.57) .12 1.89 to 2.10 16 (1.89 - 1.73) .13 2.11 to 2.22 22 (2.11 - 1.89) M1 M2 B: Non-cyclic C: Cyclic-1 D: Cyclic-2 To program a tax table, first make a table like the right table shown above. From the tax table, calculate the differences between a minimum break point and the next one (A). Then, from the differences, find irregular cycles (B) and regular cycles (C and D). These cycles will show you the following items necessary to program the tax table: T: Q: M1: M2: M: 98 The tax amount collected on the minimum taxable amount (Q) The minimum taxable amount The maximum value of the minimum breakpoint on a regular cycle (C). We call this point “MAX point.” The maximum value of the minimum breakpoint on a regular cycle (D). We call this point “MAX point.” Range of the minimum breakpoint on a regular cycle: difference between Q and M1 or between M1 and M2 Procedure T max. three digits One- or two-*1 digit number @ . 2710 @ Q max. five digits @ @ @ *2 Rate max. six digits (0.0001 - 99.9999%) M max. four digits @ Minimum breakpoint max. five digits @ Ç Repeat until the MAX point is entered. To delete a tax table, use the following sequence: 2710 . @ One- or two-*1 digit number @ @ *2 Rate max. six digits (0.0001 - 99.9999%) M max. four digits @ t *1 First figure: The first figure to be entered depends upon whether the difference between a minimum breakpoint to be entered and the preceding minimum breakpoint is not less than $1.00 or more than 99¢. When the difference is not less than $1.00, enter “1,” and when it is not more than 99¢, enter “0” or nothing. Second figure: The second figure depends upon whether your tax table is to be programmed as tax table 1, 2, 3 or 4. When your tax table is to be programmed as tax table 1, enter “1”; when it is to be programmed as tax table 2, enter “2”; when it is to be programmed as tax table 3, enter “3”; and when it is to be programmed as tax table 4, enter “4”. *2 If the rate is fractional (e.g. 4-3/8%), then the fractional portion (3/8) would be converted to its decimal equivalent (i.e. .375) and the resulting rate of 4.375 would be entered. Note that the nominal rate (R) is generally indicated on the tax table. Note If you make an incorrect entry before entering the M in programming a tax table, cancel it with the Then program again from the beginning correctly. c key; and if you make an error after entering the M, cancel it with the ı key. • Limitations to the entry of minimum breakpoints Your register can support a tax table consisting of no more than 72 breakpoints. (The number of breakpoints is 36 maximum when the breakpoint difference is $1.00 or more.) If the number of breakpoints exceeds the register's table capacity, then the manual entry approach should be used. Example Programming the sample tax table shown on the previous page as tax table 1 Key operation Print 2710 . @ 1@ Tax rate → 6@ M → 100 @ T → 1@ Q → 11 @ 23 @ The first 39 @ cyclic 57 @ portion 73 @ 89 @ M1 (MAX point)→ 111 @ a Note You do not need to enter the trailing zeros of the tax rate (after the decimal point) but you do need to enter the decimal point for fractions. 99 • If the tax is not provided for every cent, modify the tax table by setting the tax for every cent in the following way. When setting the tax, consider the minimum breakpoint corresponding to unprovided tax to be the same as the one corresponding to the tax provided on a large amount. Sample tax table Example 8% Tax .00 .01 .02 .03 .04 .06 .09 .10 .11 .12 .14 .17 Modification of the left tax table Minimum breakpoint .01 .11 .26 .47 .68 .89 1.11 1.26 1.47 1.68 1.89 2.11 .00 .01 .02 .03 .04 .05 .06 .07 .08 .09 .10 .11 .12 .13 .14 .15 .16 .17 Breakpoint difference (¢) Minimum breakpoint Tax .01 .11 .26 .47 .68 .89 .89 1.11 1.11 1.11 1.26 1.47 1.68 1.89 1.89 2.11 2.11 2.11 T 1 10 (0.11-0.01) 15 (0.26-0.11) 21 (0.47-0.26) 21 (0.68-0.47) 21 (0.89-0.68) 0 (0.89-0.89) 22 (1.11-0.89) 0 (1.11-1.11) 0 (1.11-1.11) 15 (1.26-1.11) 21 (1.47-1.26) 21 (1.68-1.47) 21 (1.89-1.68) 0 (1.89-1.89) 22 (2.11-1.89) 0 (2.11-2.11) 0 (2.11-2.11) Q M1 M2 B: Non-cyclic C: Cyclic-1 D: Cyclic-2 From the modified tax table above; Rate = 8(%), T = $0.01 = 1¢, Q = $0.11 = 11¢, M1 = 1.11, M2 = 2.11, M = 100 The tax rate PGM 2 2711 Procedure 2711 . @ A* 1 to 4 @ When the lowest taxable amount is zero Tax rate @ max. six digits: 0.0001 to 99.9999% Lowest taxable amount a max. five digits: 1¢ to $999.99 (Note: A minimum value of 1 must be entered.) To delete a tax rate, use the following sequence: 2711 . @ A* 1 to 4 @ Tax rate @ t max. six digits: 0.0001 to 99.9999% *A: When you program a tax rate as tax rate 1, enter “1”; when you program it as tax rate 2, enter “2”; when you program it as tax rate 3, enter “3”; and when you program it as tax rate 4, enter “4”. 100 Example Programming the tax rate 4% as tax rate 2 with tax exempt as 12¢ Key operation Print 2711 . @ 2@ 4@ 12 a Note • If you make an incorrect entry before pressing the third @ key in programming a tax rate, cancel it with the c key; and if you make an error after pressing the third @ key, cancel it with the ı key. Then program again from the beginning correctly. • You do not need to enter the trailing zeros of the tax rate (after the decimal point), but you do need to enter the decimal for fractions. Doughnut tax exempt (for the Canadian tax system) PGM 2 2715 Procedure To program zero 2715 Note . @ Quantity for doughnut tax exempt (max. 2 digits: 1 to 99) a This option is available only when your register has been set up with the Canadian tax system. Example To program the quantity “6” Key operation Print 2715 . @ 6a 101 4 Programming for departments Your machine is equipped with 20 (ER-A520)/10 (ER-A530) standard departments and a maximum of 99 departments. Your machine allows you to perform the following programming for each department. Functional programming 1 PGM 2 2110 Direct You can set each department for: Item validation printing If item entries must be validated, program corresponding departments for compulsory validation printing. Tare table number Tare table number associated with scale entry (0 thru 9, 0: not used) Scale entry Program a department for scale entry allowed when your store needs automatic scale entries. Registration type • If an entry of a department programmed for SICS is made first, the scale will be finalized as soon as the department key is pressed. If the entry is made after entering a department not programmed for SICS, the sale will not be finalized until the Ç key is pressed. • Whenever a sale is made to a department programmed for SIF, the sale is finalized as soon as the department key is pressed. Department type You may program each department as one of the following three types. • Normal department • Hash department A hash department is used to enter the amount of a special “sale”, such as a gift certificate sale or for the receipt of payment for utility bills, theatre tickets, etc., i.e. “non-sales” registrations. Any amounts entered in this department are not added to the grand total except tax amounts. • Bottle Return (BR) • Gas department The gas department enables you calculate the quantity of gas sold in gallon by using a preset unit price when the sale amount of gas is entered. (quantity of gas = sales amount entered / preset unit price) Also gas discount can be automatically applied to the sales. (discount amount = total amount of gas x reduced unit price for each media; cash/check/charge) Note If your register has not been set for “Bottle return, Hash and gas dept.” by your dealer, you cannot program the department for those operations. So contact your dealer if you need them. Type of unit price entry You may select one of the following four types of unit price entry for each department. • Open and preset • Preset only • Open only • Inhibit department key 102 Procedure To program any dept. To program zero 2110 . @ @ Dept. code (1 - 99) t *ABCDEF Ç To program the next sequential dept. *1 Item: A Selection: Non-compulsory Compulsory Item validation printing B C Tare table number Scale entry D Registration type E Department type F Type of unit price entry Example Inhibit Enable Compulsory Normal SICS (Single Item Cash Sale) SIF (Single Item Finalization) Normal department Hash department Bottle return department Gas department Inhibit department key Open only Preset only Open and preset Entry: 0 1 0 thru 9 (0: not used) 0 1 2 0 1 2 0 1 2 3 0 1 2 3 Programming for department 3 Enter ABCDEF=000003 for department 3. Key operation Print 2110 . @ 3 @ 000003 t Ç A thru F 103 Functional programming 2 PGM 2 2111 Direct Sign (plus/minus) • Assign a plus sign to departments for normal sales transactions. • Assign a minus sign to departments for minus transactions. Food stamp status • Assign a food stamp status (food stamp eligible or food stamp ineligible) to each department. Tax status (taxable 1 thru 4/non-taxable) • When an entry of a taxable department is made in a transaction, tax is automatically computed according to the associated tax table or rate. Note Tax 4 is prohibited if you use the food stamp function. Procedure To program any dept. To program zero 2111 @ . Dept. code (1 - 99) @ t *ABCDEF Ç To program the next sequential dept. * Item: A Sign (+/-) B Food stamp status C Tax 4 status D Tax 3 status E Tax 2 status F Tax 1 status Example Selection: Plus Minus Ineligible Eligible Non-taxable Taxable Non-taxable Taxable Non-taxable Taxable Non-taxable Taxable Entry: 0 1 0 1 0 1 0 1 0 1 0 1 Programming for department 4 and 10 Enter ABCDEF=010001 for department 4. Enter ABCDEF=100000 for department 10. Key operation Print 2111 . @ 4 @ 010001 t 10 @ 100000 t Food stamp eligible and taxable 1 Ç Minus dept. Note 104 When you program the last dept. code you are allowed to program, the programming sequence will be complete with a press of the t key. A limit amount (HALO) of entry PGM 2 2112 Direct You can set limit amounts (HALO: High Amount Lockout) for each department. The limit is effective for the REG mode operations and can be overridden in the MGR mode. The HALO limit is represented by two figures as follows: Procedure To program any dept. To program zero 2112 . @ @ Dept. code (1 - 99) t *AB Ç To program the next sequential dept. “AB” is the same as A × 10B. A: Significant digit (0 through 9) B: Number of zeros to follow significant digit (0 through 7) For example, presetting 13 ($10.00) here means that amount entries of up to $10.00 are allowed in the REG mode. When you preset 17, however, the upper limit amount is 99999.99. Example Programming HALO limit of 9000.00 (95) for dept. 1 Key operation Print 2112 . @ 1 @ 95 t Ç HALO Item label PGM 2 2114 You can program a maximum of 16 characters (item label) for each department. Select the characters you want to program, referring to section “2 How to program alphanumeric characters” in chapter “PRIOR TO PROGRAMMING”. Procedure To program any dept. To keep the current setting 2114 . @ @ Dept. code (1 - 99) Character keys (max. 16 digits) t Ç To program the next sequential dept. Example Programming STEAK (steak) for dept. 1 Key operation Print 2114 . @ 1 @ STEAK t Ç 105 Unit price PGM 1 PGM 2 1110 Direct You can program unit prices up to a maximum of six digits ($9999.99). Even if a department is not programmed to allow the entry of preset unit prices in functional programming 1 (job #2110), the department is automatically changed to allow the entry of preset unit prices by this programming entry. Procedure To program any dept. To program zero 1110 . @ @ Dept. code (1 - 99) t Unit price (max. 6 digits) Ç To program the next sequential dept. Example Programming $10.00 for dept. 1 Key operation Print 1110 . @ 1 @ 1000 t Unit price Ç Commission group assignment PGM 2 2115 Direct Your machine allows you to assign a commission group (1 – 9, 0: non commission) to each department. Procedure To program any dept. To program zero (for non commission) 2115 . @ @ Dept. code (1 - 99) Commission group (1 - 9) Ç t To program the next sequential dept. Example Programming commission group 1 for dept. 1 and commission group 2 for dept. 5 Key operation Print 2115 . @ 1@1t 5@2t Ç 106 Commission group no. Group number 2116 PGM 2 Direct You can assign departments to a maximum of 9 groups (1 thru 9). This programming enables you to take the group department sales reports. Procedure To program any dept. To program zero (For non group) 2116 @ . @ Dept. code (1 - 99) Group number (0 - 9, 0: non group) t Ç To program the next sequential dept. Example Programming the group number 1 for dept. 1 and the group number 2 for dept. 2 Key operation Print 2116 . @ 1@1t 2t Ç Group no. Group text PGM 2 2350 You can program a maximum of 8 characters (group name) for each department group. Select the characters you want to program, referring to section “2 How to program alphanumeric characters” in chapter “PRIOR TO PROGRAMMIN”. Procedure To program any group number To keep the current setting 2350 . Example @ Group number (1-9) @ Character keys (max. 8 digits) t Ç Programming DINNER for group number 1 Key operation Print 2350 . @ 1 @ DINNER t Ç 107 Age limitation 2180 PGM 2 If an item sold is not allowed to be sold to certain aged persons by law, program the age limitation for the corresponding department. Procedure To program any dept. To program zero (for no limitation) 2180 . @ @ Dept. code (1 - 99) Ç t Age limitation (1 - 99) To program the next sequential dept. Note When a department for which a setting other than zero (1 to 99) has been programmed as the age limitation is entered, the birthday entry will be enforced. Example Programming the age limitation “18” for dept. 2 Key operation Print 2180 . @ 2 @ 18 t Ç Age limitation Print station assignment 2118 PGM 2 When you use a remote printer, please consult your dealer. Procedure 2118 . To program zero @ @ Dept. code *A B C t Ç To program for the following dept. * Item: A Remote printer 1 output B Remote printer 2 output C Printing on the chit receipt Example Selection: Output Not output Output Not output Yes No Key operation Entry: 1 0 1 0 1 0 Print 2118 . @ 9 @ 101 t Ç Print station 108 Department key positioning PGM 2 2119 You can assign a department code to each key position. Each key position has a corresponding key number. Departments may be freely selected for the number of department keys and their positions. To assign the department to a key position, select the key number of the position. For key number positions, refer to section “3 Standard key number layout” in chapter “KEYBOARD”. Procedure To program any key number Cancellation 2119 . @ @ Key number (max. 3 digits) Ç t Dept. code (1 - 99) To program the next sequential key number Note The key number placement is determined by your local authorized SHARP dealer. Example Key operation Print 2119 . @ 1@1t 2t Ç Key no. Color Video Monitor (CVM) control character PGM 2 2158 This programming enables you to assign each department with a number that can be used as a CVM control character. This number is converted to a two-digit character code that is transmitted for use with a CVM device. Procedure To program any dept. To program zero 2158 . @ @ Dept. code (1 - 99) CVM control character (0 - 255) t Ç To program for the following dept. Example Programming 16 as CVM control character for department 1 Key operation Print 2158 . @ 1 @ 16 t Ç Character code converted 109 5 PLU/UPC programming The cash register can deal PLU codes and UPC codes. A PLU code consist of 5-digits number and leading zeros can be applied to the PLU code. Your machine has two kinds of PLU registration methods: Direct PLU registration: Accomplished by pressing item key (direct PLU key) directly. Indirect PLU registration: Accomplished by making an entry of PLU code and pressing the PLU/ UPC key. UPC codes are basically codes for barcode reading. With regard to the UPC codes available for this register, please refer to "Universal Product Code(UPC) or European Article Number(EAN)" in this chapter. For UPC codes, the cash register has a UPC master file as a standard and a dynamic UPC file as an option. Normally you use the UPC master file for saving the data programmed for UPC codes by using job numbers. For the data entered in the UPC learning function mode, which is details in "UPC learning function", is stored in the dynamic UPC file if your register has (if not, the register stores the data in the UPC master file). With regard to data stored in the dynamic UPC file, you can edit the data or if necessary you can create programming data in the dynamic file. The data in the dynamic UPC file can download into the UPC master file. The phrase of “Dynamic UPC file” is indicated at the right side of job codes for the programming jobs whose data is stored in the dynamic UPC file. Your machine provides 2000 PLU/UPC codes as a standard, and a maximum of 15000 PLU/UPC codes. Each PLU/UPC allows you to program the following: PLU/UPC code (PLU: max. 5 digits, UPC: 6 to 13 digits) Associated department When a PLU/UPC is associated with a department, the following functions of the PLU/UPC depend on the programming for the corresponding department. • Type (Bottle return/Hash/Normal) • Single item cash sale/Single item finalization • HALO (for “Open” type) • Item validation print compulsory/non-compulsory Unit price (max. six digits) You will usually have unit prices programmed for individual PLUs/UPCs as PLU/UPC unit prices. If you program unit price “0.00” for a PLU/UPC, you can enter only the selling quantity into the PLU/UPC, i.e. the PLU/UPC can be used only as a counter. When your register is allowed to enter multiple prices (up to 6), you can program 6 different prices for one PLU/UPC code. Base quantity for split-pricing entries – two digits Program a base quantity for each PLU/UPC dedicated to split-pricing entries. Type of unit price entry • If “Preset only” is selected, individual PLU/UPC entries can be made by entering the assigned code and pressing the PLU/ UPC key (or by pressing a direct PLU key without any PLU code entry, or by scanning the UPC code). • If “Open only” is selected, the PLU/ UPC key must be pressed after the price entry followed by the PLU code and the PLU/ entry (, or the unit price must be entered before pressing a direct PLU key). UPC • If “Open and preset” is selected, the entries in both “Preset” and “Open” types are available. • If the delete mode is selected, the corresponding program data for each PLU/UPC is deleted. • If the prohibit mode is selected, the PLU/UPC code cannot be entered. This mode does not clear the PLU/UPC program data. 110 Sign (+/-) The function of every PLU/UPC varies according to the combination of its sign and its associate department’s sign as follows: Sign Function of PLU/UPC Dept. PLU/UPC + + Serves as a normal plus PLU/UPC – – Serves as a normal minus PLU/UPC + – Accepts store coupon entries, but not split-pricing entries. – + Not valid; not accepted. Food stamp status and tax status (taxable 1, 2, 3 and/or 4, non-taxable) Item label (max. 16 characters) Tare table number and scale entry Age limitation Commission group (1 to 9) PLU/UPC group (1 to 99) and group text (max. 8 characters) Mix-and-match table (max. 10 tables) Condiment table (max. 99 tables) Set PLU (for only PLU) You can link a maximum of 10 PLUs to a particular PLU. Link PLU/UPC link A PLU/UPC is able to link to any other PLU (e.g. bottle deposit). However, the number of links is a maximum of 5. Even if more than 5 PLUs are linked, the sixth or higher link is not actualized (ignored). Print station Delete period for non-accessed UPC codes Non-PLU code format PLU level assignment and direct PLU key positioning Stock quantity Item label for remote printer (max. 12 characters) Control character for color video monitor Note For some items, you can program in two ways: programming an individual PLU code and for a range of sequential PLU codes. The procedure marked “For each PLU” shows individual PLU programming. The procedure marked “For a range of PLUs” shows sequential range PLU programming. Associated department PGM 1 PGM 2 1200 2230 Direct 1050 (Dynamic UPC file) Procedure For each PLU/UPC To program any PLU/UPC Ä 1200 1050 . @ PLU code (max. 5 digits) UPC code (6 to 13 digits) Note @ Associated dept. code (max. 2 digits) t Ç To program for the following PLU/UPC As soon as the programming is completed for one PLU/UPC, the next code appears in the display. 111 For a range of PLUs @ . 2230 Start PLU code (max. 5 digits) Note To apply the current setting of start PLU code to PLUs within the range @ End PLU code (max. 5 digits) @ t Associated dept. code (1 - 99) PLU codes must have already been defined. If not, an error message "NO RECORD" will appear on the display. Example Programming for PLU 1 for “Associate department 2” For each PLU/UPC Key operation Print 1200 . @ 1@2t Dept. code Ç Example For a range of PLUs Programming the PLU 11 thru 20 for “Associate department 3” Key operation Print 2230 . @ 11 @ 20 @ 3t Ç 112 Ç Unit prices PGM 1 PGM 2 1210 Direct 1060 (Dynamic UPC file) Procedure To program for the following PLU/UPC To keep current setting Ä 1210 1060 . @ @ PLU code (max. 5 digits) UPC code (6 to 13 digits) Unit price (max. 6 digits) ı Ç * To program unit price 2 thru 6 (only when price shift function is allowed) To program for the following PLU/UPC To program any PLU/UPC * In case that price shift function is allowed, the register prompts to enter a unit price for the following level by displaying “P2” thru “P6” on the display, and when a unit price of level 6 is entered, the register goes to the status for programming the following PLU/UPC. When you press the Ç on the way of programming multiple prices for a PLU/UPC code, prices for the remained levels are kept unchanged. In case that single price entry is allowed for a PLU/UPC code, the register goes to the status for programming the following PLU/UPC. Note The preset amount will work as the unit price for the “Preset” type and as the HALO amount for the “Open” type. In the case of the “Open” type, zero preset prevents amount entry and a 9999.99 preset is the maximum limitation. In the case of the “Preset” type zero and 9999.99 preset have no special meaning. (i.e. 0 amount preset is available.) Example Programming “$1.25, $1.50, $2.00, $2.50, $3.00, $4.00” for price level 1 thru 6 of PLU1 Key operation Print 1210 . @ 1 @ 125 t 150 t 200 t 250 t 300 t 400 t Unit price Ç 113 Base quantity PGM 1 PGM 2 1211 Direct 1061 (Dynamic UPC file) Procedure To program any PLU/UPC Ä @ . 1211 1061 Example To program zero @ PLU code (max. 5 digits) UPC code (6 to 13 digits) Ç t Base q’ty (max. 2 digits) To program for the following PLU/UPC Programming “12” for PLU 2 Key operation Print 1211 . @ 2 @ 12 t Base q'ty Ç Functional programming 1 PGM 2 2210 2231 Direct 2060 (Dynamic UPC file) Procedure For each PLU/UPC To program any PLU/UPC Ä . 2210 @ 2060 PLU code (max. 5 digits) @ UPC code (6 to 13 digits) To program zero *ABCDEFG t Ç To program for the following PLU/UPC For a range of PLUs . 2231 Start PLU code (max. 5 digits) Note 114 @ @ To apply the current setting of start PLU code to PLUs within the range End PLU code (max. 5 digits) @ *ABCDEFG t Ç When new PLU codes are created in the range specified, the default values are applied to the programming items other than the items set in this programming. * Item: A Delete method (for only UPC) For PLU, always enter 1. B D Condiment type PLU (for only PLU) For UPC, always enter 0. Condiment entry (for only PLU) For UPC, always enter 0. Price shift entry E F Tare table number Scale entry G Type of unit price entry C Example Selection: Delete in non-accessed UPC deleting job (#105 in Z1 mode) Inhibit to delete in non-accessed UPC deleting job (#105 in Z1 mode) Disable Enable Allowed Compulsory Enable Inhibit Compulsory Entry: 0 1 0 1 0 1 0 1 2 0 thru 9 (0: Not used) Inhibit 0 Enable 1 Compulsory 2 Prohibit mode 0 Open price only (for only PLU) 1 Preset price only 2 Open price and preset price (for only PLU) 3 Delete mode 4 To program ABCDEFG=1000003 for PLU1 For each PLU/UPC Key operation Print 2210 . @ 1 @ 1000003 t Ç A thru G To program ABCDEFG=1000003 for PLU11 thru 20 For a range of PLUs Key operation Print 2231 . @ 11 @ 20 @ 1000003 t Ç 115 Functional programming 2 2211 PGM 2 2232 Direct 2061 (Dynamic UPC file) Procedure To program any PLU/UPC For each PLU/UPC Ä . 2211 @ 2061 To program zero @ PLU code (max. 5 digits) UPC code (6 to 13 digits) *ABCDEF t Ç To program for the following PLU/UPC For a range of PLUs . 2232 Start PLU code (max. 5 digits) Note @ @ 116 End PLU code (max. 5 digits) @ *ABCDEF t Ç For a range of PLUs: PLU codes must have already been defined. If not, an error message "NO RECORD" will appear on the display. * Item: A Sign (+/-) B Food stamp status C Tax 4 status D Tax 3 status E Tax 2 status F Tax 1 status Note To apply the current setting of start PLU code to PLUs within the range Selection: Plus Minus Ineligible Eligible Non-taxable Taxable Non-taxable Taxable Non-taxable Taxable Non-taxable Taxable Entry: 0 1 0 1 0 1 0 1 0 1 0 1 Tax status (taxable 1 thru 4/non-taxable) Tax 4 is prohibited if you use the food stamp function. A PLU/UPC not programmed for Tax 1 thru Tax 4 statuses is registered depending on the tax status of the department which the PLU/UPC belongs to. Example Programming ABCDEF=010001 for PLU 1 For each PLU/UPC Key operation Print 2211 . @ 1 @ 010001 t Ç Taxable 1 Food stamp eligible Programming the range PLU 11 thru 20 for ABCDEF=000001 For a range of PLUs Key operation Print 2232 . @ 11 @ 20 @ 000001 t Ç 117 Item label PGM 2 2214 2064 (Dynamic UPC file) You can program a maximum of 16 characters (item label) for each PLU/UPC. Select the characters you want to program, referring to section “2 How to program alphanumeric characters” in chapter “PRIOR TO PROGRAMMING”. Procedure To program any PLU/UPC Ä 2214 2064 . @ PLU code (max. 5 digits) @ UPC code (6 to 13 digits) To keep the current setting Character keys (max. 16 digits) t Ç *To program for price levels 2 thru 6 (only when price shift function is allowed) To program for the following PLU/UPC * In case that price shift function is allowed, the register prompts to enter an item level for the following level by displaying "P2" thru "P6" on the display, and when an item level of level 6 is entered, the register goes to the status for programming the following PLU/UPC. You must enter texts for all price levels. In case that single price entry is allowed for a PLU/UPC code, the register goes to the status for programming the following PLU/UPC. Example Programming “MILK_1, MILK_2, MILK_3, MILK_4, MILK_5, MILK_6” for price levels 1 thru 6 of PLU1 Key operation Print 2214 . @ 1 @ MILK_1 t MILK_2 t MILK_3 t MILK_4 t MILK_5 t MILK_6 t Ç 118 Commission groups PGM 2 2215 2235 Direct 2065 (Dynamic UPC file) You can assign PLUs/UPCs to commission groups (1 to 9). Procedure For each PLU/UPC To program any PLU/UPC Ä @ . 2215 2065 @ PLU code (max. 5 digits) UPC code (6 to 13 digits) To program zero Commission group (0 - 9, 0: non commision) t Ç To program for the following PLU/UPC For a range of PLUs @ . 2235 Start PLU code (max. 5 digits) Note @ To apply the current setting of start PLU code to PLUs within the range @ End PLU code (max. 5 digits) Commission group (0 - 9, 0:non commision) t Ç For a range of PLUs: PLU codes must have already been defined. If not, an error message "NO RECORD" will appear on the display. Example Programming the commission group 1 for PLU 1 For each PLU/UPC Key operation Print 2215 . @ 1@1t Ç Commission group no. Programming all of PLU 11 thru 20 for the commission group 1 For a range of PLUs Key operation Print 2235 . @ 11 @ 20 @ 1t Ç 119 Group number 2216 PGM 2 2066 (Dynamic UPC file) You can assign PLU/UPCs to a maximum of 99 groups. Each PLU/UPC can belong to a maximum of three groups. Procedure 2216 2066 To program any PLU/UPC @ . PLU code (max. 5 digits) UPC code (6 to 13 digits) Ä To program zero @ *ABCDEF t Ç To program for the following PLU/UPC * AB: Group number (0 to 99) for group 1 CD: Group number (0 to 99) for group 2 EF: Group number (0 to 99) for group 3 Example Programming 01/10/50 (Group 1/2/3) for PLU1 Key operation Print 2216 . @ 1 @ 011050 t Ç Group nos. Group text PGM 2 2351 You can program a maximum of 8 characters (group name) for each PLU/UPC group. Select the characters you want to program, referring to section “2 How to program alphanumeric characters” in chapter “PRIOR TO PROGRAMMING”. Procedure To program any group number To keep the current setting 2351 . Example @ Group number (1-99) Character keys (max. 8 digits) Programming DRINK for group number 1 Key operation Print 2351 . @ 1 @ DRINK t Ç 120 @ t Ç Age limitation PGM 2 2280 2236 2081 (Dynamic UPC file) If an item sold is not allowed to be sold to certain aged persons by law, program the age limitation for the corresponding PLU/UPC. Procedure For each PLU/UPC To program any PLU/UPC Ä @ . 2280 2081 To program zero (for no limitation) @ PLU code (max. 5 digits) UPC code (6 to 13 digits) t Age limitation (1 - 99) Ç To program for the following PLU/UPC For a range of PLUs @ . 2236 Start PLU code (max. 5 digits) Note To apply the current setting of start PLU code to PLUs within the range @ End PLU code (max. 5 digits) @ Age limitation (0 - 99, 0: no limitation) t Ç • PLU codes must have already been defined. If not, an error message "NO RECORD" will appear on the display. • When a PLU/UPC for which a setting other than zero (1 to 99) has been programmed as the age limitation is entered, the birthday entry will be enforced. Example Programming the age limitation “18” for PLU 2 For each PLU/UPC Key operation Print 2280 . @ 2 @ 18 t Ç Age limitation 121 Programming the PLU 11 thru 20 for the age limitation “18” For a range of PLUs Key operation Print 2236 . @ 11 @ 20 @ 18 t Ç Stock quantity PGM 1 1222 PGM 2 1220 1221 You can assign a stock quantity to each PLU/UPC code. (If you want to control a stock quantity, please consult your dealer.) When you assign it for the first time, follow the below procedure: Procedure To program any PLU/UPC Ä 1222 . @ @ PLU code (max. 5 digits) UPC code (6 to 13 digits) Example To clear the stock quantity Ç t Stock q’ty (max. 7 digits) To program for the following PLU/UPC To program the stock quantity “10” for PLU 2 Key operation Print 1222 . @ 2 @ 10 t Ç Stock q ty Note • If you assign another stock quantity to the PLU/UPC code which you have assigned a stock quantity to, it will be overridden. • You must use a decimal point (.) key when setting quantities that are fractional. If you need to add or subtract a stock quantity, follow the below procedure: Procedure To program any PLU/UPC Ä Addition: 1220 Subtraction: 1221 122 . @ PLU code (max. 5 digits) UPC code (6 to 13 digits) @ Stock q ty to be added or subtracted (max. 7 digits) t To program for the following PLU/UPC Ç Adding the stock quantity Example To add the stock quantity “4” to the current stock quantity “10” of PLU2 Key operation Print 1220 . @ 2@4t Ç Added stock q’ty Subtracting the stock quantity Example To subtract the stock quantity “1.5” from the current stock quantity “14” of PLU 2 Key operation Print 1221 . @ 2@1.5t Ç Set PLU PGM 2 Subtracted stock q’ty 2221 Procedure To program any PLU Cancellation t To repeat up to 10 times 2221 . @ PLU code (max. 5 digits) @ Tied PLU code (max. 5 digits) t t Ç To program the next sequential PLU Note PLU codes must have already been defined. You can program a maximum of 15 set PLUs. A set PLU can be tied to a maximum of 10 PLUs. Example Programming the set PLU 20 (tied PLUs: PLU 201 and PLU 202) Key operation Print 2221 . @ 20 @ 201 t 202 t Ç Tied PLUs 123 Mix-and-match table PGM 2 2217 2225 2067 (Dynamic UPC file) The mix-and-match table consists of the adjustment amount and the matching count for discount (satisfying the count of entered items). You can program a maximum of 99 mix-and-match tables. One table can be assigned maximum of 5 kind of items. [Ex.] Mix-and-match table no. 1: matching count=3, adjustment amount $7.00 Mix-and-match items of table no. 1: Item-A ($2.30), Item-B ($3.10), Item-C ($2.50)Item-A $2.30 Item-A $2.30 Item-B $3.10 Subtotal (Discount Total $7.70 $0.70) $7.00 Item-C $2.50 Item-C $2.50 Item-C $2.50 Subtotal (Discount Total Item-A $2.30 Item-B $3.10 Item-C $2.50 $7.50 $0.50) Subtotal (Discount $7.00 Total $7.90 $0.90) $7.00 Programming of matching count and adjustment amount Procedure To program any other table Cancellation 2225 . @ Table no. (1 - 99) @ t *ABCDEFGH Ç * AB: Matching count (1 - 99) CDEFGH: Adjustment amount (max. 6 digits) Example Programming mix-and-match table no.1 (matching count=3, adjustment amount $5.00) Key operation Print 2225 . @ 1 @ 03000500 t Adjustment amount Ç Matching count Assigning items to the mix-and-match tables Procedure To program any PLU/UPC Ä 2217 2067 124 . @ PLU code (max. 5 digits) UPC code (6 to 13 digits) @ To program zero Table no. (1 - 99) t To program for the following PLU/UPC Ç Example Programming mix-and-match table no.1 for PLU 1 Key operation Print 2217 . @ 1@1t Ç Mix-andmatch table no. PLU condiment table PGM 2 2222 2223 The “condiment entry” is intended to guide the operator in making menu entries which require special cooking instructions. For example, a cashier/server can make such entries as “garnishing potato,” “with salad,” and “grilling steak rate.” When a cashier/server enters a menu-item PLU to which PLUs for the condiment entry have been assigned, these orders (such as “garnishing potato”) will be printed on the receipt and conveyed to the kitchen. Before you program for the condiment entry, prepare a condiment table. The following shows an example of a condiment table: Condiment table Table number 01 02 04 99 PLU codes for condiment entry (programmed text) Message text (HOWCOOK?) Message text (WITH?) 23 (RARE) 44 (SALAD) Message text (POTATO?) Message text (DRINK?) 33 (P.CHIPS) 63 (TEA) 27 25 (MED.RARE) (WELLDONE) 45 (FRUITS) 37 (MASHED.P) 65 (MILK) 38 (BAKED.P) 67 (A.JUICE) PLUs (Up to 15 for a table) 02 Condiment tables (Up to 99) 99 Next condiment table number 125 The condiment table should contain the following: Condiment table: The condiment table is a group of condiment PLUs, which is assigned to each menuitem PLU. A table consists of a message text and up to 15 PLUs. Also, you can assign the next condiment table number to a condiment table to link them. The message text is used for displaying a prompting message. The PLU is used for the special order setting. For example, when a server enters a menu-item PLU, a display message programmed for the message text such as “HOWCOOK?.” will appear. Then specify one of the PLU programmed for text such as “RARE.” Table number: The table number is intended to identify each condiment table. Assigning PLU condiment table number Procedure To program zero 2222 . @ @ PLU code (max. 5 digits) Condiment table# (0 - 99, 0: not used ) t Ç To program for the following PLU code To program any PLU Example Programming condiment table #1 for PLU 15 Key operation Print 2222 . @ 15 @ 1 t Ç Condiment table # 126 Assigning PLUs for condiment entry Procedure @ . 2223 To delete @ Condiment table# (1 - 99) @ *ABC After repeating 15 times t PLU code (max. 5 digits) t Ç To repeat up to 15 times To program any other table *A: Repeat times (1 to 9) BC: Next table# (00 to 99: 00: not applied) Example Programming repeat time 1 and next condiment table #2 and PLU 23/24/25 for PLUs for condiment entry for condiment table #1. Key operation Print 2223 . @ 1@ 102 @ 23 t 24 t 25 t Matching count Repeat times t Ç Note Next table # PLU codes must have been already defined. Print station to PLU/UPC assignment PGM 2 2218 2068 (Dynamic UPC file) When you use a remote printer, consult your dealer. Procedure Scan UPC code Ä 2218 . @ 2068 PLU code (max. 5 digits) UPC code (6 to 13 digits) To program zero @ *ABC t Ç To program for the following PLU/UPC To program any PLU/UPC * Item: A Remote printer 1 output B Remote printer 2 output C Printing on the chit receipt Selection: Output Not output Output Not output Yes No Entry: 1 0 1 0 1 0 127 Example Key operation Print 2218 . @ 9@ 101 t Ç Print station Delete period for non-accessed UPC codes PGM 2 2029 You can delete the UPC codes which have not been accessed during the period you set in this program when you execute the job #105 in Z1 mode when you set “Delete in non-accessed UPC deleting job” in the UPC delete method (#2210). Procedure To program “00” 2029 . @ Delete period * (1 to 99 days) Ç * When you select “00” for the period, no UPC code is deleted by the non-accessed UPC deleting job. Example Key operation 2029 . @ 60 Ç 128 Print Programming Non-PLU code format 2025 PGM 2 The register allows you to specify the Non-PLU code format (flag code: 2, 02, 20 -29). The format data is as follows: C Flag (02 or 20-29) C 2 D Free format D Free format Flag Price check digit Field 1 Field 2 Free format area Procedure To delete 2025 . ` *1 ` Flag code (max. 2 digits) *1 Flag code: 2, 02, 20 - 29 *2 Item: *2 ABCDEF Selection: A B C D Length of field 1 (number of digits) Length of field 2 (number of digits) Always enter 0. Meaning of field 2*3 E Price check digit used F TAB or decimal point of field 2 (0, 1, 2, 3) ı c Entry: 0-9 0-9 0 2 0 1 0 0-3 (Fixed position) Quantity Price Yes No *3: When you preset a quantity, the sales amount is calculated as follows: quantity x unit price programmed in #1210. Example P 2 0 Flag code C D PLU no. D Price Price check digit (TAB2) Key operation Print 2025 . ` 20 ` 540012 ı ABCDEF c Flag code 129 Link PLU/UPC link 2220 PGM 2 Procedure To program any PLU/UPC Cancellation Ä 2220 . @ @ PLU code (max. 5 digits) t To repeat up to 5 times Ç t t Linked PLU code (max. 5 digits) UPC code (6 to 13 digits) To program for the following PLU/UPC Note PLU/UPC codes must have already been defined. You can program a maximum of 15 link PLUs/UPCs. A link PLU/UPC can be linked to a maximum of 5 PLUs. Example Programming so that PLU 25, 26 and 27 are linked to PLU 21 Key operation Print 2220 . @ 21 @ 25 t 26 t 27 t Linked PLUs Ç Programming of PLU levels and direct PLU keys PGM 2 2219 You can assign PLU codes to fixed keys in each PLU level and use those keys as direct PLU key. For assigning a PLU level, press the l, ¬, Ò, L4 or L5 key or enter level number and press the ä key. For example, if you want to assign PLU level 1 and key no. 1 to a PLU code, press the l key and enter 1 before entering the PLU code. For key no. position, refer to section “3 Standard key number layout” in chapter “KEYBOARD”. Procedure To program any key no. Level no. (1-5) 2219 . @ ä l ¬ Ò Cancellation Key no. (max. 3 digits) @ PLU code (max. 5 digits) t Ç To program the next sequential key no. L4 L5 To keep the current level Note 130 • PLU codes must have already been defined. • The key number placement is determined by your local Authorized SHARP Dealer. Example Programming of PLU 1 (level 1) and PLU 65 (level 2) are assigned to key no. 21 Key operation Print 2219 . @ 21 l @ 1t ¬ 21 @ 65 t Ç Key no. Item label for remote printer PGM 2 2244 2094 (Dynamic UPC file) You can program a maximum 12 characters (item label) for each PLU/UPC which are printed by remote printers. Select the characters you want to program, referring to section “2 How to program alphanumeric characters” in chapter “PRIOR TO PROGRAMMING”. Procedure To program any PLU/UPC Ä 2244 2094 . @ @ PLU code (max. 5 digits) UPC code (6 to 13 digits) To keep the current setting t Character keys (max. 12 digits) Ç *To program for price levels 2 thru 6 (only when price shift function is allowed) To program for the following PLU/UPC * In case that price shift function is allowed, the register prompts to enter a remote printer item level for the following level by displaying “P2” thru “P6” on the display, and when an item level of level 6 is entered, the register goes to the status for programming the following PLU/UPC. You must enter texts for all price levels. In case that single price entry is allowed for a PLU/UPC code, the register goes to the status for programming the following PLU/UPC. Example Programming “MILK_K1, MILK_K2, MILK_K3, MILK_K4, MILK_K5, MILK_K6” for price levels 1 thru 6 of PLU1 Key operation Print 2244 . @ 1 @ MILK_K1 t MILK_K2 t MILK_K3 t MILK_K4 t MILK_K5 t MILK_K6 t Ç 131 Color Video Monitor (CVM) control character PGM 2 2258 2234 2059 (Dynamic UPC file) This programming enables you to assign each PLU/UPC with a number that can be used as a CVM control character. This number is converted to a two-digit character code that is transmitted for use with a CVM device. Procedure To program any PLU/UPC For each PLU/UPC Ä @ . 2258 2059 @ PLU code (max. 5 digits) UPC code (6 to 13 digits) To program zero CVM control character (0 - 255) Ç t To program for the following PLU/UPC For a range of PLUs @ . 2234 Start PLU code (max. 5 digits) @ To apply the current setting of start PLU code to PLUs within the range @ End PLU code (max. 5 digits) CVM control character (0 - 255) t Ç For a range of PLUs: PLU codes must have already been defined. If not, an error message "NO RECORD" will appear on the display. Note Example Programming 16 as CVM control character for PLU1 For each PLU/UPC Key operation Print 2258 . @ 1 @ 16 t Ç Character code converted Programming the range PLU11 through 20 for CVM control character 16 For a range of PLUs 132 Key operation Print 2234 . @ 11 @ 20 @ 16 t Ç 6 Programming for miscellaneous keys Only function keys which you have allocated on the keyboard will allow this programming. Rate (%, ç, commission, gratuity, 1310 CA TIP , CH TIP ) and discount (-) PGM 1 PGM 2 Direct You can program percent rates, currency conversion rates, commission rate, gratuity rate, tip-in rate and discount amount. Procedure 1310 @ . *1 Function no. @ To program zero *2 Rate or amount s a To program any function *1: Function no. 1: For the - key 2: For the – key 3: For the — key 4: For the ≠ key 5: For the ± key 6: For the % key (∞) 7: For the § key 8: For the ¶ key 9: For the • key 10: For the ∞ key 106: For the ç key 107: For the " key 108: For the # key 173: For the commission sale 1 174: For the commission sale 2 175: For the commission sale 3 176: For the commission sale 4 177: For the commission sale 5 178: For the commission sale 6 179: For the commission sale 7 180: For the commission sale 8 181: For the commission sale 9 87: For the gratuity CA CH 141: For the TIP and TIP keys (tip-in) *2: Rate or amount 0 — 999999 (Discount amount) 0.00 — 100.00 (% rate) 0.0000 — 9999.9999 (Currency conversion rate) 0.00 — 999.99 (Commission rate) 0.00 — 100.00 (Gratuity rate) 0.00 — 100.00 (Tip-in rate) Example Assigning $10.00 to the - key, 10.25% to the % key, and 1.325 to the ç key. Key operation Print 1310 . @ 1 @ 1000 ı 6 @ 10 . 25 ı 106 @ 0 . 8063 ı Discount amount Percent rate a Conversion rate Note • You must use a decimal point when setting percentage rates that are fractional. • When amount entry is selected for tip-in entry on the programming job #2616, you cannot program for function number 141. 133 Gas discount unit price PGM 1 PGM 2 1311 Procedure To program any function To program zero 1311 . @ Price * (0.0 - 99.9 cent) @ *Function no. t Ç *Decimal point is not necessary. *: Function no. 11:Gas discount when finalized by a 12:Gas discount when finalized by Å 13:Gas discount when finalized by 3 14:Gas discount when finalized by 4 15:Gas discount when finalized by É 16:Gas discount when finalized by k 17:Gas discount when finalized by CHK2 18:Gas discount when finalized by CHK3 19:Gas discount when finalized by CHK4 20:Gas discount when finalized by CHK5 Example 21:Gas discount when finalized by ( 22:Gas discount when finalized by ) 23:Gas discount when finalized by * 24:Gas discount when finalized by + 25:Gas discount when finalized by , 26:Gas discount when finalized by 6 27:Gas discount when finalized by 7 28:Gas discount when finalized by 8 29:Gas discount when finalized by 9 Programming 50.5 cents for gas discount unit price when finalized by a Key operation Print 1311 . @ 11 @ 505 t Ç Currency description text (ç) PGM 2 2334 You can program a maximum of 4 characters for each of the ç thru $ keys. Procedure To program any conv. function To keep the current setting 2334 . @ *: Function no. 106: For the ç key 107: For the " key 134 *Function no. 108: For the # key 109: For the $ key @ Character keys (max. 4 digits) t Ç Programming “Ÿ” for the " key Example Key operation Print 2334 . @ 106 @ / / / 207 º Entry using character code t Ç Currency description text A limit amount (HALO) of entry (-, † (for manual tax), 2312 CA TIP , CH TIP , r, p) PGM 2 Direct The HALO limit is in effect for the REG-mode operations but can be overridden in the MGR mode. The HALO limit is represented by two figures as follows: Procedure To program zero 2312 @ . *1 Function no. @ *2 AB s a To program any function *1: Function no. 1: For the - key 2: For the – key 3: For the — key 4: For the ≠ key 5: For the ± key 53: For the † key 95: For the r key 96: For the ® key 97: For the p key 98: For the π key 141:For the CA TIP and CH TIP key *2: AB is the same as A x 10B. A: Significant digit (0 through 9) B: Number of zeros to follow significant digit 0 through 7 (for the - thru ±, †, CA TIP and CH TIP keys) 0 through 8 (for the r, ®, p, and π keys) For example, presetting 13 ($10.00) here means that amount entries of up to $10.00 are allowed in the REG mode. CA CH You can set up AB = 17 for no limitation (for the - thru ±, †, TIP and TIP keys). You can set up AB = 18 for no limitation (for the r, ®, p, and π keys). Example Programming 13 for the - key. Key operation Print 2312 . @ 1 @ 13 ı a HALO limit 135 +/- sign, food stamp status, and tax status (%, -, gratuity) PGM 2 2311 Direct +/- sign: Programming of the +/- sign assigns the premium or discount function for each key. Food stamp status: Programming of the food stamp status decides whether a premium or discount should be dealt with as a food stamp-eligible amount or not. Tax status: Programming of the tax status decides whether a premium or discount should be dealt with as a taxable (taxable 1/2/3/4) or non-taxable amount. Note Tax 4 is prohibited if you use the food stamp function. Procedure To program any function To program zero 2311 @ . *1: Function no. 1: For the - key 2: For the – key 3: For the — key 4: For the ≠ key 5: For the ± key *1 6: For the %(∞) key 7: For the § key 8: For the ¶ key 9: For the • key 10: For the ∞ key *2: Item: A (+/-) sign B Food stamp status C Tax 4 status D Tax 3 status E Tax 2 status F Tax 1 status Example @ Function no. *2 s ABCDEF 87: For the gratuity Selection: Plus Minus Ineligible Eligible Non-taxable Taxable Non-taxable Taxable Non-taxable Taxable Non-taxable Taxable Entry: 0 1 0 1 0 1 0 1 0 1 0 1 Programming ABCDEF=100001 for the % key and ABCDEF=000000 for the § key Key operation Print 2311 . @ 6 @ 100001 ı 7 @ 000000 ı a Taxable 1 136 a Percent entry type (%) 2310 PGM 2 You can program the entry type of rates for percent entries. Procedure To program any percent function To program zero 2310 . @ *1: Function no. 6: For the %(∞) key 7: For the § key 8: For the ¶ key 9: For the • key 10: For the ∞ key Example *1 Function no. @ *2 Entry type s a *2: Entry type 0: Inhibited entry 1: Open rate only 2: Preset rate only 3: Open rate and preset rate Programming “Preset rate only” for the § key Key operation Print 2310 . @ 7@2ı a Preset rate only 137 Item% or subtotal% selection (%) PGM 2 2315 Direct Item%: Select this when a percent calculation is desired for the individual department and PLU/UPC. Subtotal%: Select this when a percent calculation is desired for merchandise subtotals. Procedure To program any percent function To program zero 2315 . @ *1: Function no. 6: For the %(∞) key 7: For the § key 8: For the ¶ key 9: For the • key 10: For the ∞ key Example *1 Function no. *2 @ A s a *2: A 0: Subtotal% 1: Item% Programming “Item%” for the § key Key operation Print 2315 . @ 7@1ı a Item% Percent rate limitation (%) PGM 2 2313 You can program the upper limit of percent rates for percent entries. Percent entries that use the upper limit may be overridden in the MGR mode. Procedure To program any percent function To program zero 2313 . @ *1: Function no. 6: For the %(∞) key 7: For the § key Note *1 Function no. 8: For the ¶ key 9: For the • key 10: For the ∞ key @ *2 Rate limitation s a *2: Rate limitation 0.00 – 100.00 (Entering 0.00 inhibits the open percent rate entry) The . key is needed only for fractional entry. Example Programming the limit to 15.5% for the § key Key operation Print 2313 . @ 7 @ 15 . 5 ı a 138 Limitation Vendor or store coupon selection (-) 2316 PGM 2 Direct Vendor coupon: Select this when the coupon is to be applied to the total sales amount. Store coupon: Select this when the coupon is to be applied to an individual department or PLU. Procedure To program any coupon function To program zero 2316 @ . *1: Function no. 1: For the - key 2: For the – key 3: For the — key Example *1 Function no. 4: For the ≠ key 5: For the ± key @ *2 A s a *2: A 0: Vendor coupon (subtotal â) 1: Store coupon (item â) Programming the “Store coupon” for the – key. Key operation Print 2316 . @ 2@1ı a Item â 139 7 Programming for the media keys Functional programming 1 PGM 2 2320 Direct You can set each media for: GLU/PBLU/Manual PB/CB entry compulsory Short amount tender entry Retention of closed GLU/PBLU file Bill (slip) print compulsory Footer printing on receipt This programming decides whether or not your machine should print a message at the foot of a receipt when a specified media key is used. Non-add code compulsory You can enforce the non-add code entry when a media entry is accepted. Change enable (over tender enable) Either change enable or disable can be selected for a corresponding media key. Validation printing compulsory If media entries must be validated, set the corresponding media for compulsory validation print. Drawer opening You can program each media key to or not to open the drawer. Amount tendered compulsory You may select amount tendered compulsory or optional for the a, Å thru É, k, and CHK2 thru CHK5 keys. You may select amount tendered compulsory or inhibited for the ( thru CH9 keys. Procedure To program any media function To program zero 2320 . @ *1 Function no. @ *2 ABCDEFGHIJ *1: Function no. 89: For the a key 90: For the Å key 91: For the Å 3 key 92: For the Å 4 key 93: For the É key 114: For the ( key 116: For the ) key 118: For the * key 140 120: For the + key 122: For the , key 124: For the ,6 key 126: For the ,7 key 128: For the ,8 key 130: For the ,9 key 132: For the k key CHK2 key 133: For the , CHK3 key 134: For the , CHK4 key 135: For the , CHK5 key 136: For the , 82: For the S key 94: For the f key 238: For the ≥ key s a *2: Item: A GLU/PBLU/Manual PB/CB entry B Short amount tender entry C Retention of closed GLU/PBLU file D Bill (slip) printing E Footer printing on receipt F Non-add code entry G Change enable (over tender enable) H Validation printing I Drawer opening J Amount tendered operation Note Selection: Enable Inhibit Compulsory Enable Disable No Yes Non-compulsory Compulsory No Yes Non-compulsory Compulsory Enable Disable Non-compulsory Compulsory Yes No Optional amount tendered for cash or check Inhibit amount tendered for charge Compulsory amount tendered Entry: 0 1 2 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 0 1 • For the S or ≥ key, always enter 0 as A thru C and E thru J. • For the f key, always enter 0 as B, G, and J. Example Programming of the * key for ABCDEFGHIJ=0000000001 Key operation Print 2320 . @ 118 @ 0000000001 ı a A thru J 141 Functional programming 2 PGM 2 2326 You can program each media key for gas discount availability and tax status (tax 1 thru 4). Procedure To program any media function To program zero 2326 *1 @ . @ Function no. *2 ABCDE s a *1: Function no. 89: For the a key 90: For the Å key 91: For the Å 3 key 92: For the Å 4 key 93: For the É key 114: For the ( key 116: For the ) key 118: For the * key 120: For the + key 122: For the , key 124: For the ,6 key 126: For the ,7 key 128: For the ,8 key 130: For the ,9 key 132: For the k key CHK2 key 133: For the , *2: Item: A Gas discount B Tax 4 calculation status C Tax 3 calculation status D Tax 2 calculation status E Tax 1 calculation status Note For the /, ? and Example CHK3 key 134: For the , CHK4 key 135: For the , CHK5 key 136: For the , 110: For the / key 111: For the ? key 112: For the ≥ key 3 Selection: Disable Enable calculate tax 4 delete tax 4 calculate tax 3 delete tax 3 calculate tax 2 delete tax 2 calculate tax 1 delete tax 1 EAT IN 3 Entry: 0 1 0 1 0 1 0 1 0 1 keys, always enter 0 as A. Programming the */ key to enable gas discount Key operation Print 2326 . @ 118 @ 10000 ı a A thru E 142 High amount lockout (HALO) for check cashing, check change, and cash in drawer PGM 2 2321 You can program the upper limit amounts for check cashing, check change, and cash in drawer. Procedure To program any function To program zero 2321 @ . *1 Function no. *1: Function no. 99: For check 1 cashing 100: For check 2 cashing 101: For check 3 cashing 102: For check 4 cashing 103: For check 5 cashing 104: For check change 138: For cash in drawer (sentinel) Example @ *2 s Limit amount a *2: Limit amount 0 thru 999999.99 (check cashing and check change) 0 thru 9999999.99 (cash in drawer) Setting the limit to $99.99 for check 1 cashing. Key operation Print 2321 . @ 99 @ 9999 ı a High amount lockout (HALO) of entry for media keys PGM 2 2322 Direct The HALO limit is in effect for REG mode operations but can be overridden in the MGR mode. The HALO limit is represented by two figures as follows: Procedure To program any media function To program zero 2322 . @ *1 Function no. @ *2 AB s a *1: Function no. 89: For the a key 90: For the Å key 91: For the Å 3 key 92: For the Å 4 key 93: For the É key 114: For the ( key 116: For the ) key 118: For the * key 120: For the + key 122: For the , key 124: For the ,6 key 126: For the ,7 key 128: For the ,8 key 130: For the ,9 key 132: For the k key CHK2 key 133: For the , CHK3 key 134: For the , CHK4 key 135: For the , CHK5 key 136: For the , *2: AB A: Significant digit (1 thru 9) B: Number of zeros to follow significant digit (0 thru 8) You can set up AB = 18 for no limitation. 143 Example Setting the HALO limit to $1000.00 (15) for the * key Key operation Print 2322 . @ 118 @ 15 ı HALO a Print station assignment 2328 PGM 2 When you use a remote printer, consult your dealer. Procedure To program any media function To program zero 2328 *1 @ . @ Function no. *2 ABC s a *1: Function no. 89: For the a key 90: For the Å key 91: For the Å 3 key 92: For the Å 4 key 93: For the É key 114: For the ( key 116: For the ) key 118: For the * key 120: For the + key 122: For the , key 124: For the ,6 key 126: For the ,7 key 128: For the ,8 key 130: For the ,9 key 132: For the k key CHK2 key 133: For the , *2: Item: A Remote printer 1 output B Remote printer 2 output C Printing on the chit receipt Example CHK3 key 134: For the , CHK4 key 135: For the , CHK5 key 136: For the , 82: For the S key 94: For the f key 238: For the ≥ key Selection: Output Not output Output Not output Yes No Programming of the * key for selecting “remote printer 1 output/remote printer 2 not output/printing on chit receipt” Key operation Print 2328 . @ 118 @ 101 ı a 144 Entry: 1 0 1 0 1 0 Print station CAT programming PGM 2 2330 When you use a credit card authorization terminal, please consult your authorized SHARP dealer. Procedure To program any media function To program zero 2330 *1 @ . @ Function no. *2 ABCDEFGHIJK a s *1: Function no. 89: For the a key 90: For the Å key 91: For the Å 3 key 92: For the Å 4 key 93: For the É key 114: For the ( key 116: For the ) key 118: For the * key 120: For the + key 122: For the , key 124: For the ,6 key 126: For the ,7 key 128: For the ,8 key 130: For the ,9 key 132: For the k key CHK2 key 133: For the , *2: Item: A CAT transaction B CAT action C CAT type D Card number printing E Card number print format F CAT signature line print G CAT expiration printing H I Always enter 0. Tip and total amount printing on authorization receipt Receipt and authorization receipt printing when the CAT entry is made at receipt OFF status Number of CAT authorization receipt J K CHK3 key 134: For the , CHK4 key 135: For the , CHK5 key 136: For the , 82: For the S key 238: For the ≥ key Selection: Entry: Non-compulsory Compulsory POST-AUTH DIAL Authorization only CREDIT DEBIT CHECK Yes No Partial (printing only part of the card number) Full (printing the entire card number) Yes No Yes No Yes No Yes No 0 1 0 1 2 0 1 2 0 1 0 1 0 1 0 1 0 0 1 0 1 0 to 9 Number of CAT authorization receipt Even when 0 is set, 1 receipt is issued. Example Programming of the * key for ABCDEFGHIJK = 00000000000. Key operation Print 2330 . @ 118 @ 00000000000 ı a A thru K 145 8 Programming of function text Programming PGM 2 2314 You can program a maximum of 8 characters for each function key and other functions using the table on the following pages. Select the characters you want to program referring to section “2 How to program alphanumeric characters” in chapter “PRIOR TO PROGRAMMING”. Procedure To program any function To keep the current setting . 2314 @ * Function no. (max. 3 digits) Character keys (max. 8 digits) @ s a * Function no.: See “List of function texts” shown below (until function no. 289). Example Programming CARD for * key Key operation Print 2314 . @ 118 @ CARD / / / ı a List of function texts Function no. 146 Key or function In default of proramming Function no. Key or function In default of proramming 9 %4 10 %5 (–) 1 (–) 2 (–) 3 (–) 4 (–) 5 %1 %2 %3 %4 %5 11 Gas discount for cash 1 GAS (–)1 27 Gas discount for charge 7 GAS (–)17 12 Gas discount for cash 2 GAS (–)2 28 Gas discount for charge 8 GAS (–)18 13 Gas discount for cash 3 GAS (–)3 29 Gas discount for charge 9 GAS (–)19 14 Gas discount for cash 4 GAS (–)4 30 Net sales tota NET1 15 Gas discount for cash 5 GAS (–)5 31 Net taxable 1 subtotal TAX1 ST 16 Gas discount for check 1 GAS (–)6 32 Gross tax 1 total GRS TAX1 1 1 2 2 3 3 4 4 5 5 6 %1 7 %2 8 %3 17 Gas discount for check 2 GAS (–)7 18 Gas discount for check 3 GAS (–)8 19 Gas discount for check 4 GAS (–)9 20 Gas discount for check 5 GAS (–)10 21 Gas discount for charge 1 GAS (–)11 22 Gas discount for charge 2 GAS (–)12 23 Gas discount for charge 3 GAS (–)13 24 Gas discount for charge 4 GAS (–)14 25 Gas discount for charge 5 GAS (–)15 26 Gas discount for charge 6 GAS (–)16 Function no. Key or function In default of proramming Function no. Key or function In default of proramming 33 Tax 1 total of refund entries RFD TAX1 80 Transfer in 34 Net tax 1 total TAX1 81 PBAL 35 Exempt tax 1 TX1 EXPT 82 Service 36 Net taxable 2 subtotal TAX2 ST 83 Deposit DEPOSIT 37 Gross tax 2 total GRS TAX2 84 Deposit refund DPST RF 38 Tax 2 total of refund entries RFD TAX2 85 Cover count COVER CT 39 Net tax 2 tota TAX2 86 Customer counter TRANS CT 40 Exempt tax 2 TX2 EXPT 87 Gratuity GRATUITY 41 Net taxable 3 subtotal TAX3 ST 88 Sales total 42 Gross tax 3 total GRS TAX3 89 Cash 43 Tax 3 total of refund entries RFD TAX3 90 Cash 2 44 Net tax 3 total TAX3 91 Cash 3 45 Exempt tax 3 TX3 EXPT 92 Cash 4 46 Net taxable 4 subtotal TAX4 ST 93 Cash 5 NET3 C ASH C ASH2 C ASH3 C ASH4 C ASH5 47 Gross tax 4 total GRS TAX4 94 Food stamp sales FSSALE 48 Tax 4 total of refund entries RFD TAX4 95 RA RA 49 Net tax 4 total TAX4 96 RA2 RA2 50 Exempt tax 4 TX4 EXPT 97 PO PO 51 Gross manual tax total GRS MTAX 98 PO2 52 Refund manual tax total RFD MTAX 99 Check cashing 1 CA/CHK1 53 TRAN.IN PBAL SERVICE PO2 Net manual tax total M–TAX 100 Check cashing 2 CA/CHK2 *54 Exempt total from GST GST EXPT 101 Check cashing 3 CA/CHK3 *55 PST total PST TTL 102 Check cashing 4 CA/CHK4 *56 GST total GST TTL 103 Check cashing 5 CA/CHK5 57 FS1 forgive FS TX1 104 Check change CHK/CG 58 FS2 forgive FS TX2 105 Food stamp change FS/CG 59 FS3 forgive FS TX3 106 Currency conversion 1 CONV 1 60 Tax total TTL TAX 107 Currency conversion 2 CONV 2 61 108 Currency conversion 3 CONV 3 62 NET Sales total including tax total N E T 2 109 Currency conversion 4 CONV 4 63 Coupon-like PLU CP PLU 110 Eat-in 1 EAT IN 1 64 Vender coupon UPC V. CP UPC 111 Eat-in 2 EAT IN 2 65 Item void VOID 112 Eat-in 3 EAT IN 3 66 Subtotal void SBTL VD 113 Food stamp in drawer FS/ID 67 Manager void MGR VD 114 Gross charge 1 CHARGE1 68 Void mode VOID 115 Refund charge 1 CHARGE1– 69 Refund REFUND 116 Gross charge 2 CHARGE2 70 Return RETURN 117 Refund charge 2 CHARGE2– 71 Hash item void HASH VD 118 Gross charge 3 CHARGE3 72 Hash item refund HASH RF 119 Refund charge 3 CHARGE3– 73 Hash item return HASH RT 120 Gross charge 4 CHARGE4 74 No sale NO SALE 121 Refund charge 4 CHARGE4– 75 Validation print counter VP CNT 122 Gross charge 5 CHARGE5 76 Bill (slip) counter BILL CNT 123 Refund charge 5 CHARGE5– 77 Drawer counter DRW CNT 124 Gross charge 6 CHARGE6 78 Dray total counter TRAY CNT 125 Refund charge 6 CHARGE6– 79 Transfer out TRAN.OUT 126 Gross charge 7 CHARGE7 Net 147 Function no. In default of proramming Function no. Key or function In default of proramming 127 Refund charge 7 CHARGE7– 174 Commission sale 2 COM.SAL2 128 Gross charge 8 CHARGE8 175 Commission sale 3 COM.SAL3 129 Refund charge 8 CHARGE8– 176 Commission sale 4 COM.SAL4 130 Gross charge 9 CHARGE9 177 Commission sale 5 COM.SAL5 131 Refund charge 9 CHARGE9– 178 Commission sale 6 COM.SAL6 132 Check 1 CHECK1 179 Commission sale 7 COM.SAL7 133 Check 2 CHECK2 180 Commission sale 8 COM.SAL8 134 Check 3 CHECK3 181 Commission sale 9 COM.SAL9 135 Check 4 CHECK4 182 Non commission sale NON COM. 136 Check 5 CHECK5 183 Commission amount 1 COM.AMT1 137 Cash + check in drawer CA/CH ID 184 Commission amount 2 COM.AMT2 138 Cash in drawer 185 Commission amount 3 COM.AMT3 139 Cash tip CA TIP 186 Commission amount 4 COM.AMT4 CH TIP CID 140 Charge tip 187 Commission amount 5 COM.AMT5 141 Tip-in (used only for PGM mode) TIP IN 188 Commission amount 6 COM.AMT6 142 Tip paid TIP PAID 189 Commission amount 7 COM.AMT7 Exempt VAT VAT EXPT 190 Commission amount 8 COM.AMT8 144 Sales average AVE. 191 Commission amount 9 COM.AMT9 145 Price level 1 for PLU/UPC LEVEL 1 192 Commission amount total COM.TTL 146 Price level 2 for PLU/UPC LEVEL 2 193 Waste (for PLU/UPC report) WASTE 147 Price level 3 for PLU/UPC LEVEL 3 194 Net sales (for PLU/UPC report) NET SLS 148 Price level 4 for PLU/UPC LEVEL 4 195 Net sales total (for PLU/UPC report) NET TL 149 Price level 5 for PLU/UPC LEVEL 5 196 Free GLU/PBLU (for GLU/PBLU report) FREE GLU 150 Price level 6 for PLU/UPC LEVEL 6 197 Closed check (for server report) CLOSE CK 151 (+) Dept. total OPEN CK 152 (–) Dept. total 153 Hash (+) dept. total 154 Hash (–) dept. total 155 (+) Bottle return total 156 (–) Bottle return total 157 Gas (+) dept. total *143 148 Key or function DEPT TL DEPT(–) HASH TL HASH(–) BTTL TL BTTL(–) GAS TL 198 Open check (for server report) 199 Percent of net sales (for server report) (%)SALES 200 Cash/check is CA/CH IS 201 Conversion1 is CONV1 IS 202 Conversion2 is CONV2 IS 203 Conversion3 is CONV3 IS 204 CCD differ CCD DIF. 158 Gas (–) dept. total 205 CCD differ total DIF. TL 159 Hash net total (for trans. report) HASH TTL 206 Subtotal SUBTOTAL 160 Waste total (for PLU/trans. report) WASTE TL 207 Merchandise subtotal MDSE ST 161 Subtotal (–) total (for trans. report) ST(–) TL 208 Tray subtotal TRAY TL 162 Subtotal % tota (for trans. report) ST% TL 209 Total 163 Item (–) total (for trans. report) (–) TL 210 Change 164 Item % total (for trans. report) % TL 211 Food stamp subtotal FS ST 165 Gas discount total (for trans. report) GASDISTL 212 Food stamp tender FS TEND GAS(–) TOTAL CHANGE 166 RA total (for trans. report) RA TL 213 Food stamp change FS CG 167 PO total (for trans. report) PO TL 214 Items ITEMS 168 Check cashing total (for trans. report) CA/CK TL 215 Copy receipt title DEPT 169 Cash total (for trans. report) CASH TL 216 Group report title GROUP 170 Check total (for trans. report) CHECK TL 217 PLU/UPC report title PLU/UPC 171 Charge total (for trans. report) CHR TL 218 Stock report title STOCK 172 Currency conversion total (for trans. report) CONV TL 219 Zero sales report title ZERO SAL 173 Commission sale 1 220 Category report title CATEGORY COM.SAL1 Function no. Key or function In default of proramming Function no. Key or function In default of proramming 221 Transaction report title TRANS. 222 Cash in drawer report title CID 223 Commission sales report title SALES 224 CCD report title CCD 259 Gas sales subtotal (for charge 3) GAS13 ST 225 Server/cashier report title SERVER 260 Gas sales subtotal (for charge 4) GAS14 ST 226 Hourly report title HOURLY 261 Gas sales subtotal (for charge 5) GAS15 ST 227 Daily net report title DAILY 262 Gas sales subtotal (for charge 6) GAS16 ST 228 GLU/PBLU report title GLU 263 Gas sales subtotal (for charge 7) GAS17 ST 229 Non-accessed UPC report title NO ACCES 264 Gas sales subtotal (for charge 8) GAS18 ST 230 Dynamic UPC report title DYN.UPC 265 Gas sales subtotal (for charge 9) GAS19 ST 231 Tax report title TAX 266 AMOUNT (text on display) AMOUNT 232 Non-add code text 267 WEIGHT (text on display) WEIGHT RF SALE # 256 Gas sales subtotal (for check 5) GAS10 ST 257 Gas sales subtotal (for charge 1) GAS11 ST 258 Gas sales subtotal (for charge 2) GAS12 ST 233 GLU/PBLU code text Refund type of sales (text on display) Copy receipt title TBL# COPY 268 234 269 Price change title PR. CHNG 235 Waste receipt title WASTE 270 Tip amount for tip edit TIP AMT 236 Bill transfer receipt title Final balance (for closed GLU report) FIN. BAL Bill separate receipt title B. T. B. S. 271 237 272 Edit tip EDIT TIP BILL 238 Final (used only for PGM mode) FINAL 273 Bill on receipt title 239 Balance BALANCE 274 RA cash total (for trans. report) RA CASH 240 Slip print message on journal SLIP PR. 275 RA2 cash total (for trans. report) RA2 CASH 241 Slip next page NEXT P. 276 RA check total (for trans. report) RA CHK 242 Balance forward BAL FWD 277 RA2 check total (for trans. report) RA2 CHK 243 Tare weight TARE WT. 278 RA charge total (for trans. report) RA CHR 244 DUE (text on display) DUE 279 RA2 charge total (for trans. report) RA2 CHR 245 Tip due (text on display) TIP DUE 280 RA food stamp total (for trans. report) 246 TAX ST (text on display) TAX ST 281 RA2 food stamp total (for trans. report) RA2 FS 247 Gas sales subtotal (for cash 1) GAS1 ST 282 PO cash total (for trans. report) PO CASH RA FS 248 Gas sales subtotal (for cash 2) GAS2 ST 283 PO2 cash total (for trans. report) PO2 CASH 249 Gas sales subtotal (for cash 3) GAS3 ST 284 PO check total (for trans. report) PO CHK 250 Gas sales subtotal (for cash 4) GAS4 ST 285 PO2 check total (for trans. report) PO2 CHK 251 Gas sales subtotal (for cash 5) GAS5 ST 286 PO charge total (for trans. report) PO CHR 252 Gas sales subtotal (for check 1) GAS6 ST 287 PO2 charge total (for trans. report) PO2 CHR 253 Gas sales subtotal (for check 2) GAS7 ST 288 PO food stamp total (for trans. report) PO FS 254 Gas sales subtotal (for check 3) GAS8 ST 289 PO2 food stamp total (for trans. report) PO2 FS 255 Gas sales subtotal (for check 4) GAS9 ST Note • The items marked with “ * ” are for Canada only. • The function no. 143 “Exempt VAT” is only effective for the Canadian tax system (2 GST, VAT type). 149 9 Server/Cashier programming The ER-A520 provides a cashier system and the ER-A530 provides a server system. Please note that texts for cashiers/servers are printed as servers (SRV/SERV) on the receipts. Server/Cashier code PGM 1 PGM 2 1400 You can assign a server/cashier code to each server/cashier. For more details, please contact your authorized SHARP dealer. Procedure To program any cashier no. To program zero 1400 . Server/Cashier no. (1 - 20) @ * Code (1 - 9999) @ a s * Programming code “0” inhibits entries of the selected server/cashier no. Example To program 1111 for server/cashier no.1 and 1014 for server/cashier no. 4 Key operation Print 1400 . @ 1 @ 1111 ı 4 @ 1014 ı Server/ Cashier code a Server/Cashier name PGM 1 PGM 2 1414 You can program a maximum of 8 characters (server/cashier name) for each server/cashier. Select the characters you want to program referring to section “2 How to program alphanumeric characters” in chapter “PRIOR TO PROGRAMMING”. Procedure To program any server/cashier code To keep the current setting 1414 Note . @ Server/Cashier code (1 - 9999) @ Character keys (max. 8 digits) s The server/cashier code must be programmed for the server/cashier by job #1400 prior to assigning text. Example To program “DICK” for server/cashier code 1111 and “PETER” for server/cashier code 1014 Key operation Print 1414 . @ 1111 @ DICK ı 1014 @ PETER ı a Server/Cashier name 150 a Functional programming 2410 PGM 2 Procedure To program any server/cashier code To program zero 2410 Note Server/cashier code (1 - 9999) @ . * AB s a The server/cashier code must be programmed for the server/cashier by job #1400 prior to the programming. * Item: A GLU/PBLU/Manual PB/CB entry B @ Drawer no. Example Selection: Non-compulsory Compulsory Use no drawer Set the drawer no. 1 or 2 Entry: 0 1 0 1 or 2 Programming AB=01 for server/cashier code 1111 Key operation Print 2410 . @ 1111 @ 01 ı a GLU/PBLU code range assignment PGM 2 2411 Procedure 2411 . @ To program zero (no assignment) To assign start code only Server/cashier code (1 - 9999) Note @ GLU/PBLU start code (1 - 9999) @ GLU/PBLU end code (1 - 9999) s a The server/cashier code must be programmed for the server/cashier by job #1400 prior to the programming. Example Assigning GLU/PBLU code 1 to 100 for server/cashier code 1111 Key operation Print 2411 . @ 1111 @ 1 @ 100 ı a GLU/PBLU range 151 Net sales % rate PGM 2 2413 Procedure To program any server/cashier code To program zero 2413 Note . @ Server/cashier code (1 - 9999) @ Net sale % rate (0.00 to 100.00) s a • You must enter the decimal for fractional rates. • The server/cashier code must be programmed for the server/cashier by job #1400 prior to the programming. Example Programming 20% for server/cashier code 1111 Key operation Print 2413 . @ 1111 @ 20 ı a 10 Programming various functions Programming for optional feature selection PGM 2 2616 Your register enables you to select the following options: OP X/Z mode availability When a cashier needs to take the cashier X/Z report, he or she will use the OP X/Z mode. This programming determines whether he or she will be allowed to use this mode. Note You can take the cashier X and Z reports in the X1/Z1 mode regardless of the above programming. Paid-out in the REG mode Refund type of sale in the REG mode Refund in the REG mode Direct void in the REG mode Indirect void in the REG mode Subtotal void in the REG mode Validation printing in a refund/return entry First item direct void PLU level shift mode • Automatic return mode: This mode automatically shift the PLU level back to level 1 (ordinary level) after a direct PLU entry. • Lock shift mode: This mode holds the current PLU level until making a level shift operation (pressing a level shift key). 152 Available mode for PLU level shift Printing of the number of purchased items Time printing on the receipt/journal Journal print form You may choose either of the following forms. • Detailed journal print that shows the details of all entries – the same information as printed on the receipt. • Summary journal print that shows information about all entries other than normal department entries (entries into “+” departments and their associated “+” PLUs). Availability of the item validation printing Validation printing in a discount (â) entry Zero skip for various reports Share % printing in dept. report Tip entry method Cover count entry Automatic return mode for PLU level • By one receipt: Returns the PLU level to level 1 after each receipt. • By one item: Returns the PLU level to level 1 after each item entry. Available mode for PLU/UPC price shift PLU/UPC price shift mode • Automatic return mode: This mode automatically shifts the price level back to price 1 (ordinary level) after the entry. • Lock shift mode: This mode holds the current price level until making a price shift selection (pressing the price shift key). Automatic return mode for PLU/UPC price level • By one receipt: Returns the price level to price 1 after each receipt. • By one item: Returns the price level to price 1 after each item entry. No sale in REG mode Void mode in REG mode Finalization when the subtotal amount is zero in the REG mode Item printing in PBLU transactions on the slip Tip-paid operation in REG mode Transfer-in/out operation in REG mode Usability of the RA entry Validation printing in a check cashing entry Validation printing in a RA entry Validation printing in a PO entry Birthday date printing for the age limitation Footer graphic logo printing Learning function of UPC entry Price change function in REG mode Printing of the price shift text on the receipt/journal Treating the EAN8 code (200XXXXC/D) Price entry after ISBN/ISSN code entry 153 Procedure To program any function no. (**P: 1-13) To program zero 2616 . @ ** P (1 - 13) @ **P: 1 * Item: A OP X/Z mode B Paid-out in REG mode C Refund type of sale in the REG mode D Refund and return in the REG mode E Direct void in REG mode F Indirect void in the REG mode G Subtotal void in REG mode H Validation printing in a refund and return entry **P: 2 * Item: A The first item direct void B PLU level shift mode C Available mode for PLU level shift D Printing of the number of purchased items E Time printing on the receipt/journal F Journal print form G Availability of the item validation printing H 154 Validation printing in a discount (â) entry *ABCDEFGH s a Selection: Enable Disable Enable Disable Enable Disable Enable Disable Enable Disable Enable Disable Enable Disable Non-compulsory Compulsory Entry: 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 Selection: Enable Disable Automatic return mode Lock shift mode REG and MGR modes MGR mode only No Yes Yes No Detailed Limited Enable Disable Non-compulsory Compulsory Entry: 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 **P: 3 * Item: A Always enter 0. B Always enter 0. C Zero skip in server/cashier report D Zero skip in transaction report E Zero skip in department report F Zero skip in PLU/UPC report G Zero skip in hourly report H Zero skip in daily net report **P: 4 * Item: A Share % printing in dept. report B Tip entry method C D E F Always enter 0. Always enter 0. Always enter 0. Cover count entry G Always enter 0. H Automatic return mode for PLU level shift Note G PLU/UPC price shift mode Automatic return mode for PLU/UPC price level Note Yes No Yes No Yes No Yes No Yes No Yes No Selection: Yes No Amount entry Fixed rate entry Non-compulsory Compulsory After each item After each receipt Entry: 0 0 0 1 0 1 0 1 0 1 0 1 0 1 Entry: 0 1 0 1 0 0 0 0 1 0 0 1 Automatic return mode for PLU level shift: This setting is available only when available mode for PLU level shift is set to automatic return mode. (See P:2/parameter B shown above.) **P: 5 * Item: A Always enter 0. B Always enter 0. C Always enter 0. D Always enter 0. E Always enter 0. F Available mode for PLU/UPC price shift H Selection: Selection: REG and MGR modes MGR mode only Automatic return mode Lock shift mode After each item After each receipt Entry: 0 0 0 0 0 0 1 0 1 0 1 Automatic return mode for PLU/UPC price level: This setting is available only when PLU/UPC price shift mode is set to automatic return mode (parameter G). **P: 6 (ABCDEFGH: Always enter 0.) 155 **P: 7 * Item: A Void mode in REG mode B C Always enter 0. No sale in REG mode D Finalization when the subtotal amount is zero in the REG mode Item printing in GLU/PBLU transaction on the slip Tip-paid operation in REG mode E F G Transfer-in/out operation in REG mode H Enable Disable Enable Disable Yes No Enable Disable Enable Disable Always enter 0. **P: 8 * Item: A Always enter 0. B Always enter 0. C Always enter 0. D Usability of the received-account entry E Validation printing in a check cashing F Validation printing in a received-account entry G Validation printing in a paid-out entry H Selection: Enable Disable Validation printing in tip-in/tip-paid operation Entry: 0 1 0 0 1 0 1 0 1 0 1 0 1 0 Selection: Entry: 0 0 0 Without limitation 0 Only for GLU/PBLU transaction 1 Non-compulsorly 0 Compulsory 1 Non-compulsorly 0 Compulsory 1 Non-compulsorly 0 Compulsory 1 Non-compulsorly 0 Compulsory 1 **P: 9 * Item: A Always enter 0. B Always enter 0. C Birthday date printing for the age limitation D E F G H Always enter 0. Always enter 0. Always enter 0. Always enter 0. Footer graphic logo printing Selection: Yes No No Yes Entry: 0 0 0 1 0 0 0 0 0 1 **P: 10 * Item: A and B Always enter 0. C Learning function of UPC entry D to H 156 Always enter 0. Selection: Yes No (Fixed position) Entry: 0 0 1 0 **P: 11 (ABCDEFGH: Always enter 0.) **P: 12 * Item: A to G H Selection: Always enter 0. Price change function in REG mode Entry: 0 0 1 Enable Disable **P: 13 * Item: A to C D Selection: E F Always enter 0. Printing of the price shift text on the receipt/journal Always enter 0. Treating the EAN8 code (200XXXXC/D) G H Always enter 0. Price entry after ISBN/ISSN code entry Example Entry: 0 0 1 0 0 1 0 0 1 Yes No Yes No Compulsory Inhibited Programming to select zero suppression for the server/cashier report, transaction report, dept. report, PLU/UPC report and daily net report, and to select non-skip printing for an hourly report. Key operation Print 2616 . @ 3 @ 00000010 ı P: 1 thru 13 a A thru H Programming the parameter of the slip printer PGM 2 2615 Procedure When A thru F are zeroes 2615 . @ *ABCDEF a * AB: Initial slip feed line (0 to 64) CD: Slip print max. line no. (0 to 99) E: Validation printing counter (1 thru 9 times) To inhibit validation printing, enter 0. F: Feed lines after printing of a tray subtotal (0 thru 9 lines) Example Entering 009910 to ABCDEF Key operation Print 2615 . @ 009910 a 157 Setting the time limit for THE TILL TIMERTM PGM 2 2617 The machine counts the number of times the drawer is left open for longer than a programmed time limit. The counter will be incremented by one each time a programmed time limit is reached. The time limit for THE TILL TIMERTM can be preset for 0 to 255 seconds. The count is printed on the general report and cashier report. Procedure To program 0 2617 . Example a Time limit 1 to 255 seconds @ Setting the time limit as 30 (seconds). Key operation Print 2617 . @ 30 a Scale tare table PGM 2 2618 The register can be programmed with up to nine tare tables and allows different tares to be assigned to them (for auto scale entries). Procedure To program 0 2618 . @ @ Table no. (1 to 9) Tare weight (0.01 to 99.99) s a To program any tare table no. Example To assign the tare weight 0.20 lbs to tare table no. 1 Key operation Print 2618 . @ 1 @ 20 ı a 158 Table no. Tare weight Programming of logo messages 2614 PGM 2 Your register can print programmed messages for customers on every receipt. On the standard model, the ER-A520 prints a graphic logo/the ER-A530 is set to print a header 3-line message on the receipt. (If you want a graphic logo customerized for your store, please consult your dealer.) If you want to print logo message, please consult your dealer too. You have five options described below. Select the characters you want to program, referring to section “2 How to program alphanumeric characters” in chapter “PRIOR TO PROGRAMMING.” Procedure To program any line no. To keep the current setting 2614 . @ *Line number (1 to 6) @ Character keys (max. 30 digits) s a * “Header 3-line message” type: 1 to 3 “Footer 3-line message” type : 4 to 6 “Header 6-line message” type: 1 to 6 “Header 3-line and footer 3-line message” type: 1 to 6 (1 to 3 as header, 4 to 6 as footer) Text 1st line Graphic logo Graphic logo Text 2nd line Graphic logo Text 3rd line Text 1st line Text 1st line Text 2nd line Text 2nd line Text 3rd line Text 3rd line Text 1st line Text 4th line Text 2nd line Text 5th line Text 3rd line Text 6th line Text 4th line Text 4th line Text 5th line Text 5th line Text 6th line Graphic logo only Example Header 3-line message Footer 3-line message Text 6th line Header 6-line message Header 3-line message and footer 3-line messages To program the following logo message by using 3 lines: YOUR STORE MESSAGE Key operation Print 2614 . @ 1@////////// ÎYOURÎ ///////t 2@///////// ÎSTOREÎ //////t 3@/////// ÎMESSAGEÎ ///t Ç (/:Space key) 159 Selection of X1/Z1 and X2/Z2 reports to be printed in the stacked report sequence PGM 2 2620 Your register is equipped with the stacked report printing function that enables multiple X/Z reports to be printed in sequence with only a single request. Procedure To cancel the stacked report sequence @ . 2620 For full reporting (non-range report) *2 @ *1 Job no. @ Start range parameter For individual reporting * 2 End range parameter s a To program any Job no. Note • A maximum of 70 steps are programmable. “1 step” means the memory size used for one norange type job no. The range type reports needs 6, 8 or 16 steps to execute the printing. Find how many steps are required at the column of Note to calculate total number of steps for the reports you want to print in sequence. • When the Z of stacked report is initiated, X only reports will be skipped. Job code numbers to be used are as follows. *1: Job no. Report name Note *2: Start/End range parameter 00 General 10 Full department 13 Full department group 20 PLU/UPC *3 Start code/End code (max. 5/13 digits) 16 steps 24 PLU/UPC stock *3 Start code/End code (max. 5/13 digits) 16 steps 27 PLU/UPC zero sales 29 PLU/UPC price category *3 Start price amount/End price amount 8 steps 30 Transaction 31 Cash in drawer 32 Commission sale 33 Tax 40 Full server/cashier 60 Hourly sales information *3 Start time/End time (0 thru 2330) Range report is available only in the X1 mode. 6 steps for a range report. 69 Dynamic UPC *3 Start code/End code (max. 13 digits) 16 steps 70 Daily net report 80 GLU/PBLU report *3 Start GLU/PBLU code/End GLU/PBLU code (1 thru 9999) 6 steps *3: Both range setting and full setting are allowed. Example To print reports 10 and 13 as a stacked report. Key operation Print 2620 . @ 10 ı 13 ı 160 a Setting the time range for hourly reports PGM 2 2619 You can set the time range for the hourly report. Procedure 2619 . When A thru C are all zeros. @ *ABC a *A: Time range To set the time range to 30 minutes (in the 24-hour system), enter 0. To set the time range to 60 minutes (in the 24-hour system), enter 1. BC: Starting time (hour = 00 to 23) Example Setting the time range to 60 minutes with the starting time being set at 7:00 Key operation Print 2619 . @ 107 a Note To change this setting, an hourly Z report (#160) must be taken prior to the changes. Programming of power save mode PGM 2 2689 Procedure 2689 * . @ *A B C D a Item: A Entering power save mode when time is displayed. BCD Time (min.) to entering power save mode since no operation is made. Example Key operation Selection: Enable Disable Entry: 0 1 1 through 254 (min.) (999: The power save mode is inhibited.) Print 2689 . @ 0030 a 161 Available GLU/PBLU codes PGM 2 2810 You can specify the range of GLU/PBLU codes available for the register. Procedure To program only one code 2810 @ . Example Start code (1 - 9999) @ End code (1 - 9999) a Programming 1 for start code and 1000 for end code Key operation Print 2810 . @ 1@ 1000 a Bill number PGM 2 2636 A consecutive bill number is automatically increased by one each time a GLU/PBLU entry is finalized. Specify a number that one less than a desired starting number. Procedure To program zero 2636 . Example @ Bill number (0-9999) Starting bill number from 1 Key operation 2636 . @ 0Ç 162 Ç Print Functional programming for the printer PGM 2 2990 You can program the printing density of the receipt/journal printer. Procedure To program zero 2990 . @ *AB Ç *AB: Printing density (00 – 99) 00 = 89% for standard density 50 = 100% for standard density 99 = 111% for standard density Example Programming “100% for standard density” Key operation Print 2990 . @ 50 Ç Editing guidance/error messages PGM 2 2641 Your register has standard guidance/error messages as indicated in the following list. For more information about the alphanumeric characters programming, see section “2 How to program alphanumeric characters” under the chapter “PRIOR TO PROGRAMMING”. Procedure To program any text no. (1 - 94) To keep the current setting 2641 . @ @ * Text no. (1 - 94) Character keys (max. 12 digits) t Ç * Text no.: See “LIST OF GUIDANCE/ERROR MESSAGES” shown on the following page. Example Programming “ENTRY ERROR” for text no. 1 Key operation Print 2641 . @ 1@ ENTRY / ERROR t Ç 163 LIST OF GUIDANCE/ERROR MESSAGES Text no. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17-19 20 21 22 23-26 27 28-29 30 31 32 33 34 35 36 37 38 164 Description Registration error Misoperation error Desired code is not programmed yet. (Reserved) Secret code error Code is not free Memory is full. Insert slip paper. The entered server/cashier’s code is not authorized. Stock is empty. Compulsory pushing the subtotal key Compulsory tendering Compulsory GLU/PBLU entry (Reserved) Compulsory cover count entry Check edit error (for manual PB entry) (Reserved) Remote printer off line (Reserved) Overlapped server/cashier error (Reserved) Power off (Reserved) Compulsory tender entry for tip Compulsory non-add code The server/cashier is not assigned. (Reserved) Overflow limitation The open price entry is inhibited. The unit price entry is inhibited. The direct non-tendering finalization after previous tender entry is inhibited. Read error of scale data In default of programming ENTRY ERROR MISOPERATION SECRET CODE NOT FREE MEMORY FULL INSERT SLIP Text no. 39-47 48 49 50 51 52 53 54 55-60 NO AUTHORITY 61 OUT OF STOCK 62 63 64 65-66 67 68-69 70 71 72-73 74 75 NO RECORD SBTL COMPUL. TEND COMPUL. PB COMPUL. COV CNT COMP C/D ERROR OFF LINE SERVER ERR. 76 POWER OFF 77 78 TIP ERROR # COMPULSORY NOT ASSIGNED 79 80 81 INH. OPEN PR 82-83 84 85 INH. UNIT PR 86 OVER LIMIT. NOT NON-TEND SCALE ERROR 87 88 89-93 94 Description (Reserved) Enter check number Enter cover count (Reserved) Weight on scale Closed check file is full. (Reserved) Entry of tare weight (Reserved) Desired code is not programmed yet. (learning function) Enter price and dept. no. Enter price and dept. no. Enter dept. no. (Reserved) REG buffer is full. (Reserved) Price entry at UPC refund PLU/UPC file is full. (Reserved) Non-accessed UPC delete job (Reserved) Closing the drawer is compulsory. Price level shift error (Reserved) Reading of undefined vender coupon UPC (Reserved) Message for prompting entry of secret code (Reserved) Data backup send success Data backup receive success Data backup communication error Backup data format error Data backup time out error (Reserved) Age limitation error In default of programming ENTER CHECK# COVER COUNT WEIGHT C.FILE FULL ENTR TARE WT NO RECORD PRICE → DEPT PRICE & DEPT ENTER DEPT# BUFFER FULL ENTER PRICE UPC FULL DELETE CLOSE DRAWER ENTER P.SFT OP ENTER ENTR SECRET# SEND OK RECEIVE OK COM. ERROR DATA ERROR TIME OUT AGE ERROR Validation message PGM 2 2642 You can program the text (3 lines) to be printed on validation slip. Up to 30 characters can be programmed per line. Procedure To program any line no. To keep the current setting 2642 . Example @ @ Line no. (1 - 3) Character keys (max. 30 digits) t Ç Programming “FOR DEPOSIT ONLY” for the check validation message Key operation Print 2642 . @ 3@ FOR / DEPOSIT / ONLY t Ç Note The ∏ key must be placed on the keyboard. Slip printer’s logo message PGM 2 2643 You can program the text (3 lines) to be printed on slip. Up to 30 characters can be programmed per line. Procedure To program any line no. To keep the current setting 2643 . Example @ @ Line no. (1 - 3) Character keys (max. 30 digits) t Ç Programming “TEXT1” for the slip printer’s logo message Key operation Print 2643 . @ 1@ TEXT1 t Ç Note The Ω key must be placed on the keyboard. 165 RS-232C channel assignment PGM 2 2690 Your register is equipped with two RS-232C interfaces. If you use the communication functions, the channel number of each RS-232C interface must be programmed by using the following procedure. To activate the communication functions, please consult your dealer. Procedure To program any function no. (**P: 1 - 3) To program zero 2690 . @ ** P (1 - 3) @ *ABCD t Ç ** P: 1 * Item: A Channel no. for the ON-LINE communication B Channel no. for print data sending (CVM) C Channel no. for the scale D Channel no. for the coin dispenser Selection: Not connected Standard channel 1 Standard channel 2 Not connected Standard channel 1 Standard channel 2 Not connected Standard channel 1 Standard channel 2 Not connected Standard channel 1 Standard channel 2 Entry: 0 1 2 0 1 2 0 1 2 0 1 2 Selection: Not connected Standard channel 1 Standard channel 2 Not connected Standard channel 1 Standard channel 2 Not connected Standard channel 1 Standard channel 2 Entry: 0 1 2 0 1 2 0 1 2 0 ** P: 2 * Item: A Channel no. for the barcode reader B Channel no. for the remote printer 1 C Channel no. for the remote printer 2 D Always enter 0. Note For the barcode reader, when you use the model ER-A6HS1, always select the standard channel 1. ** P: 3 * Item: A Always enter 0. B Channel no. for the slip printer TM-295 (see below for the selection) C D Always enter 0. Channel no. for CAT Selection: Not connected Standard channel 1 Standard channel 2 Not connected Standard channel 1 Standard channel 2 Channel no. for the slip printer TM-295 Select “Not connected” for internal printer (printing bills on receipt) Set “standard channel 1” or “standard channel 2” for TM-295 printer. 166 Note • Never enter any number other than 0, 1 and 2. • The data backup function always uses standard channel 1. Entry: 0 0 1 2 0 0 1 2 Example Assigning channel 1 to the slip printer TM-295 Key operation 3 Print 2690 . @ @ 0100 t Ç Barcode reader programming PGM 2 2691 Procedure To program zero 2691 . @ *ABCD * Item: A Data bit B Parity bit C Stop bit D Transmission speed Ç Selection: 7 bits 8 bits Non parity Odd parity Even parity 1 bit 2 bits 19200 bps 9600 bps 4800 bps Entry: 1 0 2 1 0 1 0 2 1 0 Example Key operation Print 2691 . @ 1110 Ç ABCD 167 Remote printer assignment PGM 2 2692 Procedure To program zero 2692 . @ Remote printer no. (1 or 2) * Item: A Logo text printing B Auto cutter function C Type of the printer @ Ç t *ABC Selection: Not print Print Disable Enable TM-U200 or TM-U230 TM-U220 (type B only) TM-T88(3) TM-T88(3)+Logo Entry: 0 1 0 1 0 1 2 3 Example Key operation Print 2692 . @ 1 @ 100 t Ç Second remote printer assignment PGM 2 3653 Procedure To program zero 3653 . @ Remote printer no. (1 or 2) * Item: A Second remote printer @ *A Ç t Selection: Nothing Remote printer 1 Remote printer 2 Entry: 0 1 2 Example Key operation Print 3653 . @ 1@2t Ç Remote printer 2 168 Remote printer name PGM 2 3654 Procedure To keep current setting 3654 . @ Remote printer no. (1 or 2) @ Printer name (max. 12 characters) Ç t Example Key operation Print 3654 . @ 1 @ KP1 t Ç Printer name Print format for remote printer 3655 PGM 2 Procedure To program zero 3655 . @ Remote printer no. (1 or 2) * Item: A Taxable status print B Q’ty print when q’ty is “1”. C Dept./PLU/UPC code print D Unit price print E Amount print @ t *ABCDE Selection: Not print Print Not print Print Not print Print Not print Print Not print Print Ç Entry: 0 1 0 1 0 1 0 1 0 1 Taxable status print Taxable status printing is allowed only when “amount print” (parameter E) is set to “Print”. Example Key operation Print 3655 . @ 1 @ 00000 t Ç Print format 169 Chit receipt format PGM 2 3656 Procedure To program zeros 3656 . @ *ABCDE * Item: A Taxable status print B Q’ty print when q’ty is “1”. C Dept./PLU/UPC code print D Unit price print E Amount print Ç Selection: Not print Print Not print Print Not print Print Not print Print Not print Print Entry: 0 1 0 1 0 1 0 1 0 1 Taxable status print Taxable status printing is allowed only when “amount print” (parameter E) is set to “Print”. Example Key operation 3656 . @ 00000 Ç 170 Print RS-232C interface 6110 PGM 2 6111 6112 6113 6115 6212 6213 6220 Online terminal number Procedure To program zero . 6110 @ Ç Terminal no. (max. 6 digits) Transmission line form system Procedure To program zero . 6111 @ Ç *AB * Item: A Sending of the CI signal B Line form Selection: No Sending Full duplex system Half duplex system Entry: 0 1 0 1 Selection: 4800 bps 9600 bps 19200 bps 38400 bps Entry: 4 5 6 7 Functional programming Procedure . 6112 @ *A Ç * Item: A Baud rate (38400/19200/9600/4800 bps) The selected baud rate is used for on-line communications. It is not used for the data backup function. Start code and end code Procedure To program zero 6113 . @ *ABCDEF Ç * ABC: Start code (000 – 127) DEF: End code (000 – 127) Time out setting Procedure 6115 . @ Time out time (1 – 255 sec) Ç 171 Baud rate specification for print data sending Procedure . 6212 * Baud rate 4: 4800 bps @ 5: 9600 bps Ç * Baud rate 6: 19200 bps 7: 38400 bps Start/end code specification for print data sending Procedure To program zero . 6213 @ Ç *ABCDEF * ABC: Start code - 000 to 127 DEF: End code - 000 to 127 Functional selection for print data sending Procedure To program zero 6220 . @ * Item: A Sensing of DR signal 172 B Sensing of CS signal C Sending of all print data *ABC Ç Selection: Yes No Yes No Disable Enable Entry: 0 1 0 1 0 1 Programming the CAT interface 7110 PGM 2 7111 7112 7113 7114 7115 7116 Phone number for dial out Procedure To keep the current setting . 7110 @ Ç * Character keys (max. 25 digits) * The valid characters for dialing are “0 – 9”, “W” and “,”. Password for dial out Procedure To program zero . 7111 @ * Password (max. 8 digits) Ç * The password can be programmed with zero suppression, however it is used without zero suppression (00000000 - 99999999) for dialing. Functional selection Procedure To program zero . 7112 @ *ABCD Ç * Item: A Food stamp mode B PIN PAD on CAT for DEBIT CARD C Key type for PIN PAD D Dial mode for dial out Selection: Disable Enable Yes No STATIC DUKPT INDEX Tone Pulse Entry: 0 1 0 1 0 1 2 0 1 Time out setting for time 1 (reading a credit/debit card) Procedure 7113 . @ Time out time (1 – 255 sec) Ç 173 Time out setting for time 2 (for the response of authorization) Procedure 7114 . @ Time out time (1 – 255 sec) Ç Time out setting for time 3 (for the reading of dial in/out) Procedure 7115 . @ Time out time (1 – 3000 sec) Ç Allowed cash tip rate for authorization Procedure To program zero 7116 . @ *Rate (0.00 - 100.00) Ç * You need a decimal point for fractional rate entry. 174 Secret codes to control access to the PGM1 mode, X1/Z1 mode and X2/Z2 2631 2632 mode PGM 2 2630 When a secret code has been set for that specific mode operation, before performing any PGM1 mode, X1/Z1 mode or X2/Z2 mode operation, you must enter a secret code according to the following procedure. Operating Procedure Ç Note Ç Secret code (max. 4 digits) • Once a secret code is entered, it does not need to be entered again unless the mode switch setting is changed or an operation is performed. • In case a secret code is forgotten, enter zero to cancel a secret code entry. Programming Procedure * 2630 2631 2632 To program zero (no code) . @ Secret code (max. 4 digits) Ç * 2630 for the PGM1 mode 2631 for the X1/Z1 mode 2632 for the X2/Z2 mode Example Programming secret code 1234 for X1/Z1 mode Key operation Print 2631 . @ 1234 Ç Loading dynamic UPCs to the main UPC file PGM 2 2099 The UPC master file can be updated by loading the data recorded in the dynamic UPC file to the UPC master file. Execute the following job. Procedure 2099 . @ Ç 175 Setting the AUTO key — Automatic sequencing key — X2/Z2 2900 If you program frequently performed transactions or report sequences for the AUTO keys, you can enter those transactions simply by pressing the corresponding AUTO keys during key operations. This programming can be done when your machine is in the X2/Z2 mode. Procedure . 2900 @ Delete ` (ˇ) ˇ thru 10 Transaction ` (ˇ) ˇ thru 10 Ç max. 50 times Example Programming for the ` key and ¡ key as follows: `; entering a $1.50 item (PLU2) and a $1.00 item (dept. 3) ¡; selling a $5.00 -programmed- item (dept. 2) for cash Key operation Print 2900 . @ AUTO1 setting AUTO2 setting Note 176 ` ˘ 100 3 ` ¡ 2Ç ¡ Ç • When the AUTO key has been programmed to execute a report job function etc., the mode switch must be in the corresponding position. • The AUTO sequence key can not be preset to another AUTO sequence key. 11 TRAINING mode The training mode is used when the operator or the manager practices register operations. When a training cashier has been selected, the machine automatically enters the training mode. When a training cashier has not been selected, the register automatically enters the ordinary REG mode. (For programming of a training cashier, please consult your local dealer.) The training operations are valid only in REG, MGR, and VOID mode. The training cashier memory is updated in the training mode. Other memories are not updated. Example Key operation Print 1000 2 3@3 Ç 177 12 Reading stored programs Your machine allows you to read program stored in the PGM1 and PGM2 modes. Program details and procedures for their reading Program for: Mode switch position Job code no. @ 1100 1 Departments PGM2 or PGM1 Related job code nos. Procedure For reading all codes 1100 For individual reading Start dept. code @ End dept. code Ç @ 1200 For reading all codes For individual reading Start PLU/ UPC code 2 PLUs/UPCs PGM2 or PGM1 1200 1110, 2110, 2111, 2112, 2114, 2115, 2116, 2180, 2118, 2158 @ End PLU/ UPC code For the last picking list Scan UPC code Ç MDSE SBTL Ä MDSE SBTL PLU/UPC code 1200, 1210, 1211, 2210, 2211, 2217, 2214, 2215, 2222, 2230, 2231, 2232, 2235, 2236, 2280, 2218, 2216, 2234, 2244, 2258 To pick up PLU/UPC codes 3 4 Key nos. for departments and PLUs Link PLUs/UPC link PGM2 PGM2 2119 2119 @ 2220 @ PGM2 End PLU/ UPC code Ç For reading all codes 2221 2221 For individual reading Start PLU code 178 @ 2220 @ 2221 Set PLUs 2119, 2219 For reading all codes For individual reading 2220 Start PLU/ UPC code 5 Ç @ End PLU code Ç 6 Mix-and-match table PGM2 2225 2225 @ Ç 2225 7 Condiment table PGM2 2223 2223 @ Ç 2223 8 UPC’s function PGM2 2025 2025 @ Ç 2025, 2029 Program for: Mode switch position Job code no. Related job code nos. Procedure @ 1050 For reading all codes For individual reading Start UPC code 9 Dynamic UPCs PGM2 or PGM1 1050 @ End UPC code For the last picking list Scan UPC code MDSE SBTL Ä Ç 1050, 1060, 1061, 2059, 2060, 2061, 2064, 2065, 2066, 2067, 2068, 2081, 2094 MDSE SBTL UPC code To pick up UPC codes 10 Dept. /PLU/UPC group text PGM2 or PGM1 2350 2350 @ Ç 2350, 2351 11 Servers/cashiers PGM2 or PGM1 1400 1400 @ Ç 1400, 1414, 2410, 2411 2413 12 GLU/PBLU code PGM2 2800 2800 @ Ç 2810 1310, 1311, 2310, 2311, 2312, 2313, 2314, 2315, 2316, 2320, 2321, 2322, 2326, 2334, 2328, 2330 2614, 2615, 2616, 2617, 2618, 2619, 2620, 2630, 2631, 2632, 2636, 2689, 2690, 2691, 2692 13 Function preset 1 PGM2 or PGM1 1300 1300 @ Ç 14 Function preset 2 PGM2 2600 2600 @ Ç 15 Messages PGM2 2640 2640 @ Ç 2641, 2642, 2643 16 Tax tables and rates PGM2 or PGM1 2700 2700 @ Ç 2710, 2711 17 Auto keys PGM2 2900 2900 @ Ç 2900 18 Thermal printer PGM2 2990 2990 @ Ç 2990 19 Remote printer PGM2 3650 3650 @ Ç 3653, 3654, 3655, 3656 20 On-line preset PGM2 or PGM1 6110 6110 @ Ç 21 CAT preset PGM2 7110 7110 @ Ç 6110, 6111, 6112, 6113, 6115, 6212, 6213, 6220 7110, 7111, 7112, 7113, 7114, 7115, 7116 179 Sample printouts 1 Reading of programmed items for departments (Reading in the PGM1 and PGM2 modes) Job code no. Range Dept. code Item label Mode switch position* Range Mode switch position* PLU code Commission group Group no. HALO limit. Food stamp status 2 Reading of programmed items for PLUs/UPCs (Reading in the PGM1 and PGM2 modes) Item label for price level 1 thru 6 Associated dept. code Unit price for price level 1 thru 6 Tax status Tax status Function Function programming programming Print station CVM control character Remote printer item label for price level 1 thru 6 Age limitation Commission group Group Base q’ty Minus department CVM control character Age limitation * When you take this report in the PGM1 mode, the PGM2 indication is replaced by “PGM1”. 180 Condiment table no. Stock Mix and match table no. Set PLU L: Link PLU 3 Reading of programmed key nos. for departments and PLUs (Reading in the PGM2 mode) 5 Reading of programmed set PLUs (Reading in the PGM2 mode) Key no. Dept. code Tied PLU code 6 Reading of mix-and-match table (Reading in the PGM2 mode) PLU code Mix-and-match table no. Adjustment amount Matching count 7 Reading of condiment table (Reading in the PGM2 mode) Table no. Assigned PLU code Next condiment table no. Number of repeats 4 Reading of programmed items for link PLUs (Reading in the PGM2 mode) 8 Reading of programmed UPC’s function (Reading in the PGM2 mode) Range Leading PLU code Linked PLU code Non-PLU code format Delete period for non-accessed UPC 181 9 Reading of programmed Dynamic UPC (Reading in the PGM1 and PGM2 mode) Mode switch position* The subsequent printout occurs in the same format as in the sample reading of programmed items for PLUs/UPCs. 11 Reading of programmed items for servers/cashiers (Reading in the PGM1 and PGM2 modes) Server/cashier name Server/cashier no. Mode switch position* Server/cashier code Drawer no. GLU/PBLU/ manual PC/CB entry Net sale % * When you take this report in the PGM1 mode, the PGM2 indication is replaced by “PGM1”. * When you take this report in the PGM1 mode, the PGM2 indication is replaced by “PGM1”. 10 Reading of programmed department and PLU/UPC group text (Reading in the PGM2 mode) Department group no. Text PLU group no. 182 12 Reading of programmed GLU/PBLU code (Reading in the PGM2 modes) 13 Reading of programmed items for functions - 1 (Reading in the PGM1 and PGM2 modes) To be continued on the next page * When you take this report in the PGM1 mode, the PGM2 indication is replaced by “PGM1”. 183 184 14 Reading of programmed items for functions - 2 (Reading in the PGM2 mode) Logo message Line feed for tray subtotal Optional feature selection Drawer open alarm time Scale tare tables Hourly report format/start hour Stacked report Secret code Bill number Power saving mode RS-232C channel data Barcode reader data Remote printer data 185 15 Reading of programmed messages (Reading in the PGM2 mode) Guidance/error messages Check validation message Slip printer’s logo message To be continued 186 16 Reading of programmed tax tables and rates (Reading in the PGM2 mode) 19 Reading of remote printer preset (Reading in the PGM2 mode) Tax rate Tax table Tax rate Lowest taxable amount 20 Reading of ON-LINE preset (Reading in the PGM2 mode) 17 Reading of programmed items for auto keys (Reading in the PGM2 mode) 21 Reading of CAT preset (Reading in the PGM2 mode) 18 Reading of programmed items for the thermal printer (Reading in the PGM2 mode) Printing density Entered Value Printing density example 187 13 Universal Product Code (UPC) or European Article Number (EAN) UPC or EAN code Your machine can support the following codes: • UPC-A (Number system character: 0, 2, 3, 4, 5) • UPC-E • EAN-8 • EAN-13 • Internal code EAN-8/EAN-13 For the codes used in-store marking, there are two types of PLU type (treated as a code like PLU no.) and NonPLU type (price/quantity information is included in the code). When a code is non-PLU type, the price/quantity in the code is read for sales entry (in case of quantity, “quantity multiplys preset unit price” is processed to obtain price.) UPC-A • Number system character: 0 • Number system character: 3 • Number system character: 5 For entry, a full 12 digit number or 11 digit number (omitting the check digits) must be entered. C 0 Maker code Check digit Number system character C 3 C Maker code 2 Family code * Item code * * * C D Price check digit • UPC-E is a zero-suppressed version of UPC-A that conforms to the UPC-E Standards. This code is used for marking small packages. For entry, a 6 digit number or a leading zero plus 6 digits number must be entered. EAN 8 • Ordinary EAN-8 code (flag: neither 0 nor 2) For entry, a full 8 digit number must be entered. C D Maker code Nation code Item code C 2 188 * Price UPC-E For entry, a full 8 digit number must be entered. On the receipt/journal, non-PLU type code is printed like 208**** (****: price/quantity information) D Coupon price table 4 For entry, a full 12 digit number, 11 digit number (omitting the (Free code) check digit), or a leading zero plus 12 digit number must be entered.(Any numbers are allowed for the digits marked with *, and on the receipt/journal, non-PLU type code is printed like 2020008**** (****: price information).) • Internal code (flag 2) Program the format by the job #2025. • Internal code (flag 0) D NCD (or HRI) format 5 • Number system character: 2 You can program the format by the job #2025. • Number system character: 4 D Item code D (Free format) Program the format by the job#2025. C 0 (Free code) D C D EAN-13 • Ordinary EAN-13 code (used in the source marking) • Specific EAN-13 code (flag 977, 978, 979) (used in the source marking: ISBM, ISSN) C Maker code D Item code Nation code For entry, you must enter a full of 13 digits number. • Internal code (used in the in-store marking, the flag character number: 20 through 29 and 02) Program the format by the job# 2025. C Flag 02, 20-29 D (Free format) Program the format by the job #2025. Add-on code UPC-A and EAN-13 may be followed by a two digits number or a five digits number as add-on code, excepting UPC-A without a check digit plus two or five digits add-on code. Therefore, the total number of digits enterable for sales entries are as shown below: Note Code entry No add-on code 2-digit add-on code 5-digit add-on code UPC-A 12 14 17 UPC-A w/leading zero 13 15 18 UPC-A w/o check digit 11 – – UPC-E 6 – – EAN-8 8 – – EAN-13 13 15 18 Your register automatically judges the add-on code in an UPC/EAN code entered from the total number of digits and the flag. 189 READING (X) AND RESETTING (Z) OF SALES TOTALS • Use the reading function (X) when you need to take a reading of sales information entered since the last resetting. You can take this reading any number of times. It does not affect the register’s memory. • Use the resetting function (Z) when you need to clear the register’s memory. Resetting prints all sales information and clears the entire memory except for the GT1 thru GT3 and training GT, reset count, and consecutive number. • If you want to stop the printing report, turn the mode switch to the MGR position. The symbol (“ ”) is printed. Summary of reading (X) and resetting (Z) reports and the key operations 1 to obtain the reports X1 and Z1 reports: Daily sales reports X2 and Z2 reports: Periodic (monthly) consolidation reports Item Flash report: (Only display) To clear the display, press the key or turn the mode switch to another position. c Mode switch position X1/Z1 X2/Z2 Job code Key operation 99 ) 1 to ÿ : Department total amount Dept. code à @ key: Amount of cash in drawer t key: Paid total Dept. key ( X1 — — X1, Z1 X1, Z1 100 General report X1, Z1 X2, Z2 200 X1, Z1 141 X2, Z2 Individual cashier/ server report 241 Reading 100 200 . @ Reading 141 241 Ç Resetting . For assigned cashier/server @ Cashier/server code @ Ç @ Ç Ç Resetting Reading X, Z 41 41 . Resetting Full cashier/server report X1, Z1 Reading X1, Z1 140 X2, Z2 240 140 240 Full department report X1 X1 X2 110 210 110 210 Individual group total report on department X1 X1 112 X2 212 Full group total report on department X1 X1 113 X2 213 . Resetting Ç 112 212 @ @ 113 213 @ Ç Group number Ç Reading X1, Z1 X1, Z1 120 PLU/UPC report by designated range . @ Resetting All PLUs/UPCs X2, Z2 190 120 220 220 Start PLU/ UPC code Scan UPC code @ Ä End PLU/ UPC code Scan UPC code Ä Ç Item Mode switch position X1/Z1 X2/Z2 Job code Key operation Reading X1, Z1 X1, Z1 109 109 209 . For full reading and resetting Resetting For the last picking list PLU/UPC report by pick up list @ X2, Z2 Scan UPC code Ä PLU/UPC code 209 Ç MDSE SBTL MDSE SBTL To pick up PLU/UPC codes PLU/UPC report by associated department X1, Z1 Individual group total report on PLU/UPC X1 Full group total report on PLU/UPC X1 PLU/UPC zero sales report by department X1 X1 Reading X1, Z1 121 X2, Z2 221 X1 122 X2 222 X1 123 X2 223 X1 127 X2 227 127 227 X1 129 129 229 121 221 . @ 122 222 @ Group number 123 223 @ Ç Ç Full reading @ @ PLU/UPC price category report Ç Dept. code All prices X2 229 Start price amount 124 PLU/UPC stock report Ç Dept. code Resetting End price amount @ Ç @ All PLUs/UPCs X1 X1 124 Start PLU/ UPC code Scan UPC code @ Ä End PLU/ UPC code Ç Scan UPC code Ä For full reading For the last picking list PLU/UPC stock report by pick up list 104 X1 X1 104 @ Scan UPC code PLU/UPC code MDSE SBTL Ç Ä MDSE SBTL To pick up PLU/UPC codes 191 Item Mode switch position X1/Z1 X2/Z2 Job code Key operation Reading 180 GLU/PBLU report X1, Z1 X1, Z1 . @ Resetting 180 All GLU/PBLUs @ Start GLU/ PBLU code Reading GLU/PBLU report by cashier/server X1, Z1 X1, Z1 181 181 . Ç End GLU/ PBLU code For assigned cashier/server @ Cashier/server code Ç Resetting Reading 182 Closed GLU/PBLU report X1, Z1 X1, Z1 . @ Resetting 182 All bills @ Start bill # Closed GLU/PBLU report by cashier/ server Commission sales report Tax report Reading X1, Z1 X1, Z1 183 . For assigned cashier/server @ Cashier/server code Ç Resetting X1 X1 X1 X1 132 X2 232 X1 133 X2 233 X1 130 X2 230 X1 131 X2 231 Transaction report Cash in drawer report 183 Ç End bill # X1 132 232 @ Ç 133 233 @ Ç 130 230 @ Ç 131 231 @ Ç Reading 169 . @ Resetting Dynamic UPC report by designated range X1, Z1 X1, Z1 All UPCs 169 Start UPC code Scan UPC code @ Ä Ç End UPC code Scan UPC code Ä Reading 165 . For full reading and resetting Resetting For the last picking list Dynamic UPC report by pick up list X1, Z1 X1, Z1 165 @ Scan UPC code UPC code MDSE SBTL Ä MDSE SBTL To pick up UPC codes 192 Ç Item Dynamic UPC report by associated department Mode switch position X1/Z1 X2/Z2 Job code Key operation Reading X1, Z1 X1, Z1 166 166 . @ Ç Dept. code Resetting Reading 168 . @ Resetting Dynamic UPC clear report by designated range X1, Z1 X1, Z1 All UPCs 168 Start UPC code Scan UPC code @ Ä Ç End UPC code Scan UPC code Ä Reading 164 . For full reading and resetting Resetting For the last picking list Dynamic UPC clear report by pick up list X1, Z1 X1, Z1 @ 164 Scan UPC code Ç MDSE SBTL Ä MDSE SBTL UPC code To pick up UPC codes Dynamic UPC clear report by associated department Reading X1, Z1 X1, Z1 167 167 . @ Dept. code Ç Resetting X1 Reading: 160 (For individual time range) X1 @ End* time 160 Hourly report X1, Z1 @ Ç * Enter the time in the 24-hour system. Reading and Resetting: X1, Z1 Start* time Reading . 160 @ Ç Resetting X1, Z1 X1, Z1 Reading 190 Stacked report X2, Z2 290 X2, Z2 270 190 290 . @ Ç @ Ç Resetting When Z of stacked report is initiated, X only reports will be skipped. Reading Daily net report 270 . Resetting 193 Non-accessed UPC deleting Mode switch position X1/Z1 X2/Z2 Item Reading of non-accessed UPCs X1 X1 Job code 105 Key operation 105 @ Ç For full deleting For the last UPC picking list Deleting of non-accessed UPCs Z1 Z1 105 105 . @ Scan UPC code UPC code MDSE SBTL Ç Ä MDSE SBTL To pick up UPC codes Note 194 When you execute the job #105 in Z1 mode, not only the sales data, but also the UPC code(s) (the related data files) themselves will be deleted. 2 Daily sales totals General report You can take X and Z reports in the X1/Z1 mode. The use of the decimal (.) key determines when the report will actually reset the totals. • Sample X report • Sample Z report Report no. Read symbol Dept. code Reset symbol Reset counter Net grand total (GT2 - GT3) Grand total of plus registration Grand total of minus registration Ratio of dept. 1 sales amount to “+” real dept. total Sales q'ty Grand total of training mode registration Sales amount “+” real dept. counter and total The subsequent printout occurs in the same format as in the X report. “-” real dept. counter and total “+” hash dept. counter and total “-” hash dept. counter and total “+” bottle return dept. counter and total “-” bottle return dept. counter and total gas q'ty “+” gas dept. counter, quantity sold and amount total “-” gas dept. counter, quantity sold and amount total To be continued on the next page Note Not all reports provide the resetting capability. Please refer to the chart on pages 190-194. 195 Subtotal 4 counter and total Subtotal total Subtotal % 3 counter and total Subtotal % total Gas discount counter and total (cash 1 - 5) Gas discount counter and total (check 1 - 5) Gas discount counter and total (charge 1 - 9) Gas discount total Net sales total Net taxable 1 total Gross tax 1 total Refund tax 1 total Net tax 1 total Exempt total from tax 1 *1 Gross manual tax total Refund manual tax total Net manual tax total FS tax 1 forgiveness total FS tax 2 forgiveness total FS tax 3 forgiveness total (When the Canadian tax system is selected) Tax total Sale total excluding tax Sales total including tax To be continued on the next page *1 When food stamp function is allowed, tax 4 items are not printed. 196 Exempt total from GST PST total GST total Item 1 counter and total Item 1 total Item % 1 counter and total Item % total Coupon-like PLU counter and total Vender coupon UPC counter and total Eat-in 1 counter and total Item void counter and total Subtotal void counter and total Manager item void counter and total Void-mode transaction Refund counter and total Return counter and total Hash item void counter and total Hash item refund counter and total Hash item return counter and total * No-sale (exchange) counter Validation print counter Bill counter Drawer counter Tray subtotal counter GLU/PBAL counter Service counter Cover counter Trans-out counter and total Trans-in counter and total Customer counter Average of sales amount Gratuity total Sales total (including hash dept. total) Hash net sales total Waste total Cash counter and total Cash total Sales for food stamp counter and total RA1 by cash counter and total RA1 by check counter and total RA1 by charge counter ant total RA1 by food stamp counter and total RA1 total RA total * When manual PB/CB function is enabled, amount is also printed for each print item. 197 PO1 by cash counter and total PO total Check cashing 1 counter and total Check cashing total Cash change total for check and charge tendering Cash change total for food stamp tendering Currency conversion 1 total (by programmed rate) Currency conversion 4 total (by manual rate) Currency conversion total Food stamp in drawer total Charge 1 counter and total Charge 1 refund/return counter and total Charge total Check 1 counter and total Check total Cash + check in drawer Cash in drawer Deposit counter and total Deposit refund counter and total Tip-paid counter and total Cash tip counter and total Charge tip counter and total 198 Cashier/Server report Using this function, you can take X and Z reports for individual cashiers/servers or all cashiers/servers. Individual cashier/server reading and resetting The OP X/Z-mode reading and resetting is allowed only when your machine has been programmed Note for "OP X/Z mode available" in the PGM2 mode. • Sample X report Cashier no. • Sample Z report Cashier/server code Cashier/server name Sales total Vender coupon UPC counter and total Gratuity total Cash tip total Charge tip total Tip-paid total Customer counter Cover counter The subsequent printout occurs in the same format as in the sample X report. Commission 1 sales total Commission 1 amount (commission 1 sales total x commission 1 rate) * When you take these reports in the OP X/Z mode, the X report shows an “OP X” and the Z report shows an “OP Z”. Commission amount total Non-commission sales total Full cashier/server reading and resetting The printout occurs in the same format as in the sample report of individual cashier/server, but all cashiers/servers' sales data are printed in the order of cashier/server code number (from #1 to #20), and then the total of all cashiers/servers is printed. 199 Hourly report You can take X and Z reports for sales totals and transaction (customer) counters for 48 half hours, or 24 hours. If both quantity and amount are zero, their print is skipped. • Sample X report • Sample Z report The subsequent printout occurs in the same format as in the sample X report. Customer counter Sales total Cover counter Average sales amount per customer (sales total ÷ customer counter) 200 Full department report Individual group total report on department Sales q’ty Amount Ratio of dept. 1 sales amount to + real dept. total Group 1 total Full group total report on department Group 1 total 201 PLU/UPC report (by designated range or pick up list) This function provides you with X and Z reports for sales information of PLUs/UPCs. You can select either of the designated range operation or pick up list operation. The range may represent all or part of the PLUs/UPCs in your register. • Sample X report • Sample Z report Range*1 PLU code Item label for price level 1 Item label for price level 2 Sales q'ty and total (for price level 1) Waste mode q'ty and total*2 The subsequent printout occurs in the same Net sales q'ty and total*2 format as in the sample X report. Net sales % Note *1: The PLU/UPC range is not printed in pick up report (#109). *2: Not printed when waste mode is disabled PLU total for price level 1 PLU total for price level 2 202 UPC code UPC total for price level 1 UPC total for price level 6 203 PLU/UPC report by associated department • Sample X report • Sample Z report The subsequent printout occurs in the same format as in the sample X report. The subsequent printout occurs in the same format as th ePLU/UPC report by designated range. Individual group total report on PLU/UPC PLU code Item label for price level 1 Full group total report on PLU/UPC Group text Sales q'ty and amount for price level 1 Sales q’ty and amount for PLU group 11 Group 1 sales q'ty and amount 204 PLU/UPC zero sales report by department PLU/UPC stock report (by designated range or pick up list) Associated dept. code* Item label PLU code Range Current stock * When printing full zero sale report, no associated dept. code is printed. PLU/UPC price category report Note The PLU/UPC range is not printed in pick up report (#104). Price amount range Sales q’ty and total (for price level 1) Commission sales report Commission 1 (sales total) Commission 1 (amount) Commission amount total Non-commission sales Net sales total 205 GLU/PBLU report • Sample Z report • Sample X report GLU/PBLU code Cover counter Range Cashier/server code The subsequent printout occurs in the same format as in the sample X report. GLU/PBLU report by cashier/server • Sample X report • Sample Z report The subsequent printout occurs in the same format as in the sample X report. 206 Closed GLU/PBLU report • Sample X report • Sample Z report The subsequent printout occurs in the same format as in the sample X report. 207 Closed GLU/PBLU report by cashier/server • Sample X report • Sample Z report The subsequent printout occurs in the same format as in the sample X report. 208 Transaction report Cash in drawer report You can take full cashier X reports for cash in drawer. Cashier no. Cashier name Customer counter Sales total Cash in drawer In this report the same transaction data as those printed when general reading is taken are printed except department sales totals. Tax report *1 *2 *3 *1 Not printed when food stamp function is allowed. *2 Printed only when Canadian tax is selected. *3 Not printed when Canadian tax is selected. 209 Dynamic UPC report (by designated range or pick up list) The printout occurs in the same format as in the sample report of PLU/UPC report (by designated range or pick up list) . Dynamic UPC report by associated department The printout occurs in the same format as in the sample report of PLU/UPC report by associated department. Dynamic UPC clear (by designated range or pick up list) Please note that the UPCs specified for this report are deleted from the dynamic UPC file when Z report is issued. The printout occurs in the same format as in the sample report of PLU/UPC report (by designated range or pick up list) . Dynamic UPC clear by associated department Please note that the UPCs specified for this report are deleted from the dynamic UPC file when Z report is issued. The printout occurs in the same format as in the sample report of PLU/UPC report by associated department. X1/Z1 stacked report You can print multiple X1/Z1 reports in sequence at a single time. In this case, you need to program in advance what X1/Z1 reports should be printed in the stacked report sequence. Note 210 The following job code numbers (only) can be used for stacked report printing. Job code number: 100, 110, 113, 120, 124, 127, 129, 130, 131, 132, 140, 160, 180 Refer to “Selection of X1/Z1 and X2/Z2 reports to be printed in the stacked report sequence” for further details. Deleting of non-accessed UPCs • Sample X report (Reading) • Sample Z report (Deleting) UPC code Item label Periodic sales* The subsequent printout occurs in the same format as in the sample X report. *: When there is any sales data of the UPC for #209 report, the data in printed here. When you delete the UPC in Z1 mode under the this situation, the data for #209 is also deleted. 211 3 Periodic consolidation Your register allows you to take consolidation X and Z reports of a chosen period (normally one week or a month). General Overview The periodic reading or resetting reports are the same in format as those in the X1/Z1 report for daily total except job code no. (#2xx) and mode indication (“X2” or “Z2”.) • Sample X report • Sample Z report Reset symbol Reset counter of daily total Reset counter of periodic consolidation Read symbol Grand total The subsequent printouts are the same in format as those in the X/Z report for daily total. Daily net report • Sample X report • Sample Z report The subsequent printout occurs in the same format as in the sample X report. * *: Overflowed data will be printed with the indication of at the date column. / X2/Z2 stacked report You can print multiple X2/Z2 reports in sequence at a single time. In this case, you need to program in advance what X2/Z2 reports should be printed in the stacked report sequence. Note 212 The following job code numbers (only) can be used for stacked report printing. Job code number: 200, 210, 213, 220, 227, 229, 230, 231, 232, 240, 270 Refer to “Selection of X1/Z1 and X2/Z2 reports to be printed in the stacked report sequence” for further details. COMPULSORY CASH/CHECK DECLARATION If you want to make the declaration of the cash and check amount in the drawer mandatory before performing cashier Z reports, please consult your dealer and have your register programmed for compulsory cash/check declaration. If your register is programmed for compulsory cash/check declaration (CCD), a cashier must first count and declare the cash and check amounts (of domestic and foreign currency) in the drawer, before he or she can performing a cashier report. The procedure for outputting a CCD report is shown below. Types of compulsory cash/check declarations • Compulsory declaration prior to individual cashier resetting • Compulsory declaration prior to full cashier resetting • Compulsory cash/check declaration is available in the above two types. You can choose either of these. Please consult your dealer for further details. • When the cash/check declaration is compulsory, flash reports are not available. Note Key operation After the Ç key is pressed, the register prompts the cashier to input the cash and check accounts for both domestic and foreign currency. The cashier can simply input the total amounts of each currency unit, or the number of bills or coins of each denomination of each currency unit. • Individual cashier report OP X/Z mode 41 . @ The drawer opens and the cashier is prompted to enter the cash and check amounts. (“CCD” is displayed.) Input the check or currency denomination = ç # X1/Z1 mode 141 . @ Ç Q’ty @ X v Ç to Amount = ç # to • Full cashier report X1/Z1 mode 140 . @ Input the total amount of cash or check To cancel previous entry To repeat t To display cash/check subtotal = : When inputting the cash or check amount (domestic currency) in the drawer ç to # : When inputting the amount of a foreign currency in the drawer 213 CCD entry amount Currency conversion 1 in drawer to be obtained Total of entered (declared) conversion 1 in drawer Difference Check 1 (in domestic currency) in drawer to be obtained Cash/check in drawer to be obtained Total of entered (declared) cash/check in drawer Difference Total of difference Cash in drawer to be obtained 214 OPERATOR MAINTENANCE 1 In case of power failure When power is lost, the machine retains its memory contents and all information on sales entries. • When a power failure is encountered in register idle state or during an entry, the machine returns to the normal state of operation after power recovery. • When a power failure is encountered during a printing cycle, the register prints “========” and then carries out the correct printing procedure after power recovery. (See the sample print.) 2 In case of printer error If the printer runs out of paper, the printer will hault, “PAPER EMPTY” error will appear on the display. Key entries will not be accepted. Referring to “4. Installing and removing the paper roll” in this chapter, install a new roll paper in the proper position, then press the c key. The printer will print the power failure symbol and resume printing. If the print head is up, the printer haults, “HEAD UP” error will appear on the display. Key entries will not be accepted. Bring the print head to the correct position, then press the c key. The printer will print the power failure symbol and resume printing. 3 Thermal printing Your register prints by means of thermal printing. The print head applies heat to thermal paper which is chemically treated to change color when heated to a certain level. This creates the printed text. Cautions in handling the printer Printing position • If you are not going to use the register for an extended period of time, pull the print head release lever toward you so that the print head is set apart from the plate. Head-up position 215 • Avoid the following environments: Dusty and humid places Direct sunlight Iron powder (A permanent magnet and electromagnet are used in this machine.) • Use the print head release lever only when necessary. • Never pull the paper when it is in contact with the print head. First release the head with the print head release lever, and then remove the paper. • Never touch the surface of the print head. • Never touch around the print head and the motor during printing or before they have had sufficient time to cool. Cautions in handling the recording paper (thermal paper) • Use only the paper specified by SHARP. • Do not unpack the thermal paper until you are ready to use it. • Avoid heat. The paper will color at around 70°C. • Avoid dusty and humid places for storage. Avoid direct sunlight. • The printed text on the paper can discolor under the following conditions: Exposure to high humidity and temperature Exposure to the direct sunlight Contact with glue, thinner or a freshly copied blueprint Heat caused by friction from scratching or other such means Contact with a rubber eraser or adhesive tape • Be very careful when handling the thermal paper. If you want to keep a permanent record, copy the printed text with a photocopier. • Be very careful when handling the thermal paper. If you want to keep a permanent record, copy the printed text with a photocopier. • For the storage of thermal paper, it is recommended to store the paper in a box with a dark and dry atmosphere of the room temperature 5 to 25°C having no rapid temperature change. 216 4 Installing and removing the paper roll Recording paper specifications Be sure to use paper rolls specified by SHARP. The use of any other paper rolls than specified could cause paper jamming, resulting in register malfunction. Paper specification Paper width: 2.26 ± 0.02 in. (57.5 ± 0.5 mm) Max. outside diameter: 3.15 in. (80 mm) Quality: Thermal paper Paper tube: 0.71 in. (18 mm) • Be sure to set paper roll(s) prior to using your machine, otherwise it may cause a malfunction. Install the paper roll in the printer. Be careful then to set the roll and cut the paper end correctly. Note If the top end of the paper roll is fixed with paste or tape, the paper may lose its color development ability in the pasted or taped area due to the deterioration of the heat-sensitive color development component of the paper surface. This may result in nothing appearing at this location when printing is performed. Therefore, when setting a new paper roll in the machine, be sure to cut off approximately one revolution (approx. 25 cm long). (How to set the paper roll) (How to cut the paper end) To the printer To the printer Incorrect Correct Correct Incorrect Installing the paper roll Installing the receipt paper roll 1. Turn the mode switch to the “REG” position with the AC cord connected. 2. Remove the printer cover. 3. Check that the print head release lever is in its printing position. Printing position 4. Set the paper correctly as illustrated above in the receipt side of the printer. 5. Insert the end of the paper into the paper chute as shown on the left. It will automatically be fed through the printer. 6. Cut off the excess paper that comes out of the printer with the manual cutter. 7. Replace the printer cover. 217 Installing the journal paper roll 1. Turn the mode switch to the “REG” position with the AC cord connected. 2. Remove the printer cover. 3. Check that the print head release lever is in its printing position. 4. Set the paper correctly as illustrated on the previous page in Printing position the journal side of the printer. 5. Insert the end of the paper into the paper chute as shown on the left. It will automatically be fed through the printer. 6. Insert the end of the paper into the slit in the paper take-up spool. (Press the Ô key to feed more paper through if required.) 7. Wind the paper two or three turns around the spool shaft. 8. Set the spool on the bearing. 9. Replace the printer cover. • When you want to manually install a new roll of paper while your machine is turned off, follow the steps shown below: 1. Pull the print head release lever toward you to lift up the print head. 2. Correctly place the new paper roll into the receipt/journal paper roll location. 3. Insert the paper end into the paper chute until it comes out of the printer. 4. Cut or roll the paper onto the take-up spool as described for automatic installation. 5. Return the print head release lever to its original position. Note If nothing is printed when printing is performed, check the printing face of the paper is at the outer side. Also in case nothing is printed on the receipt side, please check if the receipt on/off function is set to on. Removing the paper roll When a colored dye appears on the paper roll, it is time to replace the existing paper roll. Replace the paper roll with a new one. If you plan not to use your register for an extended period of time, remove the paper roll, and store it in the appropriate place. Removing the receipt paper roll 1. Remove the printer cover. 2. Cut the paper behind the printer and near the paper roll. 3. Press the ‰ key until the paper remaining in the printer comes out completely. 4. Remove the paper roll from the back of the printer. Note 218 Do not pull the paper through the printer. Removing the journal paper roll Area to cut 1. Remove the printer cover. 2. Press the Ô key to advance the journal paper until its printed part is out of the way. 3. Cut the paper and remove the take-up spool. 4. Cut the paper behind the printer and near the paper roll. 5. Press the Ô key until the paper remaining in the printer comes out completely. 6. Remove the paper roll from the back of the printer. Note Do not pull the paper through the printer. 7. Remove the outer side of the take-up spool as shown on the left. 8. Remove the printed journal roll from the take-up spool. 219 Removing a paper jam Precaution: Be very careful with the manual paper cutter, so as not to cut yourself. Never touch the print head immediately after printing, because the head may still be hot. 1. Remove the printer cover. 2. Pull the print head release lever all the way forward (after it Pull all the way forward 220 stops at one position, continue pulling forward until it stops again and cannot be pulled forward any further). 3. Remove the paper jam. Check for and remove any shreds of paper that may remain in the printer. 4. Return the print head release lever to its original position. 5. Reset the paper roll(s) correctly by following the steps in “Installing the paper roll”. 6. Replace the printer cover. 5 Cleaning the print head When the printed text is getting dark or faint, paper dust may be stuck to the print head. Clean the print head as follows: 1. Turn the mode switch to the “OFF” position. 2. Remove the printer cover. 3. Pull the print head release lever all the way forward (after it Pull all the way forward stops at one position, continue pulling forward until it stops again and cannot be pulled forward any further). 4. Clean the print head with a soft rag moist with ethyl alcohol or isopropyl alcohol. Print head 5. Return the print head release lever to its original position immediately after cleaning. 6. Reset the paper roll correctly by following the steps in “Installing the paper roll”. 7. Replace the printer cover. Caution: • Never touch the print head with a tool or anything hard as it may damage the head. • The paper cutter is mounted on the printer (receipt side). Be careful not to cut yourself. 221 6 Removing the till and the drawer The till in the register is detachable. After closing your business for the day, remove the till from the drawer and keep the drawer open. To detach the drawer, pull it forward fully with the till removed, and remove it by lifting it up. Coin case Till Drawer 7 Opening the drawer by hand The drawer automatically opens normally. However, when power failure is encountered or the machine becomes out of order, slide the lever located on the machine bottom toward the rear. (See the figure below.) The drawer will not open if it is locked with a drawer lock key. Lever 222 8 Before calling for service The malfunctions shown in the left-hand column below, labelled “Fault,” do not necessarily indicate functional faults of the machine. It is therefore advisable to refer to the “Checking” shown in the right-hand column before calling for service. Fault Checking (1) The display won’t be illuminated even when the mode switch is turned to any other position than “OFF”. (2) The display is illuminated, but the whole machine refuses registrations. (3) No receipt is issued. (4) No journal paper is taken up. (5) Printing is unusual. • Is power supplied to the electrical outlet? • Is the power cord plug out or loosely connected to the electrical outlet? • Is a cashier code assigned to the register? • Is the mode switch set properly at the “REG” position? • Is the receipt paper roll properly installed? • Is there a paper jam? • Is the receipt function in the “OFF” status? • Is the print head release lever at the printing position? • Is the take-up spool installed on the bearing properly? • Is there a paper jam? • Is the print head release lever at the printing position? • Is the paper roll properly installed? Error message table Text no. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17-19 20 21 22 23-26 27 28-29 30 31 32 33 34 35 36 37 38 Description Registration error Misoperation error Desired code is not programmed yet. (Reserved) Secret code error Code is not free Memory is full. Insert slip paper. The entered server/cashier’s code is not authorized. Stock is empty. Compulsory pushing the subtotal key Compulsory tendering Compulsory GLU/PBLU entry (Reserved) Compulsory cover count entry Check edit error (for manual PB entry) (Reserved) Remote printer off line (Reserved) Overlapped server/cashier error (Reserved) Power off (Reserved) Compulsory tender entry for tip Compulsory non-add code The server/cashier is not assigned. (Reserved) Overflow limitation The open price entry is inhibited. The unit price entry is inhibited. The direct non-tendering finalization after previous tender entry is inhibited. Read error of scale data In default of programming ENTRY ERROR MISOPERATION SECRET CODE NOT FREE MEMORY FULL INSERT SLIP Text no. 39-47 48 49 50 51 52 53 54 55-60 NO AUTHORITY 61 OUT OF STOCK 62 63 64 65-66 67 68-69 70 71 72-73 74 75 NO RECORD SBTL COMPUL. TEND COMPUL. PB COMPUL. COV CNT COMP C/D ERROR OFF LINE SERVER ERR. 76 POWER OFF 77 78 TIP ERROR # COMPULSORY NOT ASSIGNED 79 80 81 INH. OPEN PR 82-83 84 85 INH. UNIT PR 86 OVER LIMIT. NOT NON-TEND SCALE ERROR 87 88 89-93 94 Description (Reserved) Enter check number Enter cover count (Reserved) Weight on scale Closed check file is full. (Reserved) Entry of tare weight (Reserved) Desired code is not programmed yet. (learning function) Enter price and dept. no. Enter price and dept. no. Enter dept. no. (Reserved) REG buffer is full. (Reserved) Price entry at UPC refund PLU/UPC file is full. (Reserved) Non-accessed UPC delete job (Reserved) Closing the drawer is compulsory. Price level shift error (Reserved) Reading of undefined vender coupon UPC (Reserved) Message for prompting entry of secret code (Reserved) Data backup send success Data backup receive success Data backup communication error Backup data format error Data backup time out error (Reserved) Age limitation error In default of programming ENTER CHECK# COVER COUNT WEIGHT C.FILE FULL ENTR TARE WT NO RECORD PRICE → DEPT PRICE & DEPT ENTER DEPT# BUFFER FULL ENTER PRICE UPC FULL DELETE CLOSE DRAWER ENTER P.SFT OP ENTER ENTR SECRET# SEND OK RECEIVE OK COM. ERROR DATA ERROR TIME OUT AGE ERROR 223 LIST OF OPTIONS For your register, the following Sharp options are available. For further details on additional options that may be considered, please contact your dealer. •Remote drawer models ER-03DW and ER-04DW •Till model ER-55CC2 for the standard cash drawer •Key kit models By using the following key kits, the keyboard layout can be changed on your register including the expansion of the number of departments. ER-11KT7: 30 regular size key kits ER-12KT7: 30 1 x 2 size key kits for ER-A520 only ER-22KT7: 10 2 x 2 size key kits ER-11DK7G: 30 regular size dummy key kits ER-51DK7G: 10 5 x 1 size dummy key kits •Display model UP-P16DP •RAM board model UP-S02MB 224 SPECIFICATIONS Model: Dimensions: Weight: Power source: Power consumption: Working temperature: Electronics: Built-in battery: Display: Operator display: Customer display: Printer: Type: Printing speed: Printing capacity: Other functions: Paper roll: Cash drawer: Accessories: ER-A520/A530 16.6 (W) x 16.8 (D) x 11.7 (H) in. (421 (W) x 427 (D) x 297 (H) mm) 31.7 lbs (14.4 kg) 120V ± 10% AC, 60Hz Stand-by 11 W Operating 47 W (max.) 32 to 104°F (0 to 40°C) LSI (CPU) etc. Rechargeable battery, memory holding time about 1 month (with fully charged built-in battery, at room temperature) LCD dot-matrix display (16 positions x 2 lines) 7-segment display (7 positions) 2-station thermal printer Approx. 17 lines/second 30 digits each for receipt and journal paper • Graphic logo printing function • Logo text printing function • Receipt (ON-OFF) function, journal selective function • Receipt and journal independent paper feed function Width: 2.26 ± 0.02 in. (57.5 ± 0.5 mm) Max. diam.: 3.15 in. (80 mm) Quality: High quality (0.06 to 0.08 mm thickness) 5 slots for bill and 5 for coin denominations Manager key 2 Submanager key 2 Operator key 2 Drawer lock key 2 Printer cover lock key 2 Paper roll 2 Take-up spool 1 Standard key sheet 1 (provided with the keyboard) for ER-A530 only Programming key sheet 1 (provided with the keyboard) Ferrite cores 2 (used for connection cabling installation) Leaflet 1 copy * Specifications and appearance subject to change without notice for improvement. 225 NOTICE BE SURE TO ASK YOUR AUTHORIZED SHARP DEALER ABOUT THE WARRANTY THAT YOUR SELLING DEALER EXTENDS TO YOU. In order to assure you, the end-user, of warranty protection, Sharp extends a limited warranty to each of its authorized dealers, and in turn requires each of its authorized dealers to extend its own warranty to you on terms that are no less favorable than those given to the dealer by Sharp. You should be aware, however, that Sharp does not itself extend any warranties, either express or implied, directly to you, the end-user, and no one is authorized to make any representations or warranties on behalf of Sharp. Specifically, SHARP DOES NOT EXTEND TO YOU, THE END-USER, ANY EXPRESS WARRANTY OR ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR USE OR FITNESS FOR ANY PARTICULAR PURPOSE IN CONNECTION WITH THE HARDWARE, SOFTWARE, OR FIRMWARE EMBODIED IN OR USED IN CONJUNCTION WITH THIS PRODUCT. Sharp is not responsible for any damages or loss, either direct, incidental or consequential, which you, the end-user, may experience as a result of your purchase or use of the hardware, software or firmware embodied in or used in conjunction with this product. Your sole remedy in the event that you encounter any difficulties with the product is against the authorized dealer from which you purchased the product. In the event that this authorized dealer does not honor its warranty commitments, please contact the General Manager of Sales, Retail and Financial System Division, ISG, Sharp Electronics Corporation, Sharp Plaza, P.O. Box 650, Mahwah, NJ 07430-2135 so that Sharp can try to help you to assure complete satisfaction of all the warranty rights to which you are entitled from the authorized dealer. ER-A520/A530 ELECTRONIC CASH REGISTER MODEL ER-A520 ER-A530 INSTRUCTION MANUAL SHARP ELECTRONICS CORPORATION Sharp Plaza, Mahwah, New Jersey 07430-2135 1-800-BE-SHARP http://www.sharp-usa.com SHARP CORPORATION The above illustration shows the model ER-A520. Printed in Japan ERA520/A530_MIE10
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Page Mode : UseNone XMP Toolkit : 3.1-702 About : uuid:05b1f5c6-e100-4732-90c4-894008a8b158 Producer : Acrobat Distiller 5.0.5 for Macintosh Create Date : 2004:03:08 07:39:14Z Modify Date : 2010:05:19 11:57-04:00 Metadata Date : 2010:05:19 11:57-04:00 Document ID : uuid:8482a929-7405-44a9-b6ac-8159c25e4dec Instance ID : uuid:da3b6c4e-c92b-486c-8df5-8e3979d0a6d8 Format : application/pdf Page Count : 229EXIF Metadata provided by EXIF.tools