ShenZhen Jumper Medical Equipment JPDTH100 Wireless Intelligent Thermoment User Manual

ShenZhen Jumper Medical Equipment Co.,Ltd Wireless Intelligent Thermoment Users Manual

Users Manual

Download: ShenZhen Jumper Medical Equipment JPDTH100 Wireless Intelligent Thermoment User Manual
Mirror Download [FCC.gov]ShenZhen Jumper Medical Equipment JPDTH100 Wireless Intelligent Thermoment User Manual
Document ID3642703
Application IDRlayJoskvRUmrpsvNssfPQ==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize39.72kB (496448 bits)
Date Submitted2017-11-17 00:00:00
Date Available2017-11-20 00:00:00
Creation Date2017-11-16 17:59:59
Producing SoftwareCorel PDF Engine Version 17.1.0.572
Document Lastmod2017-11-17 13:52:59
Document TitleJPD-TH100_英文说明书_80g铜版纸_单黑印_四折页_292x84mm_折后73X84mm_071917_曼联(法规检测版本).cdr
Document CreatorCorelDRAW X7
Document Author: 罗金秀

RF Exposure Informa on and Statement :
Cleaning & Disinfec ng
This equipment complies with FCC RF radia on exposure limits set forth for an
uncontrolled environment.
This device complies with part 15 of the FCC rules Opera on is subject to the
following two condi ons: (1) this device may not cause harmful interference,
and (2) this device must accept any interference received, including interference
that may cause undesired opera on.
Cleaning:
NOTE: The manufacturer is not responsible for any radio or TV interference
caused by unauthorized modifica ons to this equipment. Such modifica ons
could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for
a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protec on against harmful interference in a
residen al installa on. This equipment generates uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instruc ons, may cause harmful interference to radio communica ons.
However, there is no guarantee that interference will not occur in a par cular
installa on. If this equipment does cause harmful interference to radio or
television recep on, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more
of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separa on between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help
- This device and its antenna(s) must not be co-located or opera ng in conjunc on
with any other antenna or transmi er.
Technical Specifica ons
Wet the clean so cloth with a small amount of water or mild detergent, wring
it out and wipe the dirty parts or the sensing parts.
Acid detergent or alkaline detergent is prohibited to use.
Power supply mode
Classifica on
Type B applied parts
Disinfec ng:
Ba ery specifica on
CR 2032 bu on ba ery
Wet the clean so cloth with a small amount of medicinal alcohol (concentra on:
75%), wipe the intelligent thermometer and the sensing parts before and a er use.
(Notes: Do not soak intelligent thermometer in liquid for cleaning or disinfec ng.
Do not allow liquid to penetrate the intelligent thermometer.)
Working voltage
DC3.0V
Dimensions
Diameter:33mm; Height: 8.5mm
Weight
8.5g
Service life
2 years, produc on dateonthelabel.
Temperature range
32.0°C ~42.0°C/89.6℉ ~107.6℉
Measurement accuracy
±0.1°C/±0.2°F
Transmission distance
10m
Care & Maintenance
Put the intelligent thermometer in clean storage box and store the box in
well-ven lated and dry place a er use.
Take out the bu on ba eries of intelligent thermometer if it want be used for
a long me.
In order to avoid the damages on parts, prevent the intelligent thermometer from
falling off and violently crashing during use. Do not clean the intelligent
thermometer with acetone, gasoline and other strong solvents.
Internal power source
Frequency Range
2402-2480MHz
Troubleshoo ng
Max.RF power
Problem
Possible reason
Fail to connect
to
smartphone
A. The bu on ba ery is run
out of power;
B. The ba ery is inserted in
wrong poles.
Solu on
-1.9dBm
Opera ng environment
5°C~40°C; ≤80% RH; 70kpa ~ 106kpa
Transporta on &
storage environment
-20°C~55°C; 10% RH~93% RH; 50kpa ~ 106kpa
Store in well-ven lated room without aggressive gas.
A. Replace the ba ery.
B. Insert the ba ery based on
the right poles.
WirelessIntelligentThermometer
Model: JPD-TH100
EC REP
Wellkang Ltd
Suite B, 29 Harley Street, London W1G 9QR,UK
Shenzhen Jumper Medical Equipment Co.,Ltd.
D Building, No. 71, Xintian Road, Fuyong Street, Baoan,
Shenzhen, Guangdong, China.
Tel: +86-755-26696279
Fax: +86-755-26852025
Website: h p://www.jumper-medical.com
UserManual
Date of Issue: Mar. 10, 2017, Version: A/0
Regulatory Conformance (RED)
Hereby, Shenzhen Jumper Medical Equipment Co.,Ltd declares that the radio
equipment type JPD- TH100 is in compliance with Direc ve 2014/53/EU.
Symbol & Descrip on
Package contents
Wireless Intelligent thermometer x 1
Medical proof fabric x 1
Bu on ba ery x 1
User manual x 1
Descrip on
Symbol
Cau on, consult the instruc ons for use.
Type CF applied parts
The full text of the EU declara on of conformity is available at the following website:
h p://www.jumper-medical.com
Replace Ba ery
1. Flip the cover upwards with thumb fingernail to open the cover.
2. Take the old bu on ba ery out and insert a new one with posi ve pole upwards.
3. Align the notches of cover and ba ery box, and close the cover.
Produc on Introduc on
Wireless Intelligent Thermometer is a wearable and intelligent device that
measures body temperature, which can quickly and accurately measure the
body temperature via its medical temperature sensing parts on the bo om.
The user s cks the Intelligent Thermometer on chest with medical proof
fabric and starts app on smart phone to view the measurement results at any
me. Featuring small size, skin-friendly bo om and safe material without
toxicant and anaphylac c reac on, the Intelligent Thermometer can be worn
for 24 hours.
Intended Use
Warning: Please installing the ba ery correctly, or the instrument will be damaged.
The Intelligent Thermometer is used for measuring people’s body temperature
at home or in medical ins tu ons.
Advantages
Safe & accurate: Medical materials with high measurement accuracy;
Skin-friendly: Small size and skin-friendly design;
Economic & convenient: Replaceable bu on ba ery and reusable Intelligent
Thermometer;
Low power consump on: Switch-free design and low power consump on Bluetooth;
Convenient measurement: 24-hour monitoring and data viewing in app.
Waste electrical materials should be sent to a dedicated collec on
point for recycling.
IP20
The degree of protec on against harmful ingress of water and
par culate ma er
Components
The Intelligent Thermometer composes of the main circuit, temperature
sensing parts, bu on ba ery, shell and app in smart phone.
Wipe the Intelligent Thermometer and its temperature sensing parts with medical
alcohol for disinfec ng before and a er the measurement.
Put the Intelligent Thermometer in clean storage box and store the box in wellven lated and dry place a er use.
Please do not wash the Intelligent Thermometer with water or other liquids.
For avoiding environmental pollu on, please properly treat the old ba ery
a er replacement. In order to avoid the risk of choking, please keep the Intelligent
Thermometer and bu on ba ery out of the reach of children, immediately send the
children that swallow either of them to hospital.
It is dangerous to diagnose the illness state by yourself based on the measurement
results. Please consult the doctor if you have any concern.
Only measure the temperature of children under adult supervision.
Please do not use the Intelligent Thermometer for other purposes.
Only use the Intelligent Thermometer to measure the temperature of chest instead
of other posi ons (e.g. forehead, mouth, ears).
Wearing & Using
The Intelligent Thermometer can measure the temperature on the surface of
people’s chest, and display the results on app of smart phone through Bluetooth.
1. Open the package.
2. Take bu on ba ery out, open the cover of Intelligent Thermometer, and install
the ba ery.
3. Scan QR code with asmartphone to download an App.
4. Take a piece of medical adhesive tape and s ck the Intelligent Thermometer on
chest.
5. Turn on the Bluetooth for your smartphone, start app, scan the QR code on
Intelligent Thermometer and enter into temperature measurement interface.
6. Measure temperature, and update the result every 2 seconds.
Please do not disassemble the Intelligent Thermometer except for replacing
the ba ery.
Do not use the Intelligent Thermometer in places with strong electromagne c
field; otherwise, the Bluetooth signal may be interfered.
Keep the body s ll during measurement.
1. Download an APP
(scan the QR code on the right.)
Warning
Applica on
Precau ons
Connect to Mobile Phone
Android
ios
2. Start so ware and connect to Intelligent Thermometer Open Bluetooth in smart
phone, start app, scan the QR code on Intelligent Thermometer and connect to a
smartphone.
(Notes: The Intelligent Thermometer has no switch, so it is started up a er the
bu on ba ery is installed. The Bluetooth is in sleeping mode a er being
disconnected from smart phone.)

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : Yes
Author                          : 罗金秀
Create Date                     : 2017:11:16 17:59:59+08:00
Modify Date                     : 2017:11:17 13:52:59+08:00
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Format                          : application/pdf
Creator                         : 罗金秀
Title                           : JPD-TH100_英文说明书_80g铜版纸_单黑印_四折页_292x84mm_折后73X84mm_071917_曼联(法规检测版本).cdr
Creator Tool                    : CorelDRAW X7
Metadata Date                   : 2017:11:17 13:52:59+08:00
Producer                        : Corel PDF Engine Version 17.1.0.572
Document ID                     : uuid:62580575-2db0-41a1-a92e-15005c7f6d6a
Instance ID                     : uuid:7f13044d-012a-4b63-8371-4eb898c6af30
Page Count                      : 2
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2ADYL-JPDTH100

Navigation menu