ShenZhen Megastek Electronics S921 Home base unit User Manual S921
ShenZhen Megastek Electronics Co. Ltd. Home base unit S921
User Manual
The home base unit Model: S921 _______________________________________ ___ user manual 1 1、Product overview The home base unit S921 is an auxiliary device of the MT200 tracker,If the MT 200 tracker is within 20 meters of the home base unit S921, you can detect the normal work of MT200. beyond this range, the home base unit s921 can not detect MT200 tracker. The home base unit S921 has no waterproof function. 2、Product appearance and parameters Items input voltage Internal Battery Working current size weight Operating Temperature GSM module internal memory LED button Antenna interface Specification AC 100-240V 50/60HZ Rechargeable lithium battery 100 mAh (3.7V) 450mA 83mm X 59mm X 35mm 142g -20 ~ +55 °C Quad Band GSM 850/900/1800/1900 MHz 32M-BIT Flash memory Power LED light、GSM LED light 、wifi&BT LED light SOS button External antenna interface,for connect with 2.4GH external antenna accessories GMT921Terminal(Internal Battery) Special USB cable (optional) 2 button SOS button Bluetooth &WiFi GSM indication Power indication antenna power cord red – Power indication always on Connect external power source always off disconnect external power source Blue – GSM indication 0.3s on and 0.3s off GSM module is initializing Always on GSM network is not registered 1s on and 3s off GSM network is registered 0.1s on and 3s off GSM network is registered and connected to the server by GPRS yellow – GPS indication 1s on and 3s off module is initializing 0.1s on and 3s off module is working normally SOS button Press sos button for 3S to sent” sos “alert to platform 3 function ◆power off alarm 1、When the home base unit is connected with power , the base unit will send alarm information to the platform. 2、When the home base unit is disconnected with power , the base unit will send alarm information to the platform. ***If the device has an power off alarm function, the device must be connected to an internal battery*** ◆SOS emergency alarm When Parole pressed the SOS key, the base unit sends an alarm message to the platform. 3 ◆disassembly alarm When the Home Base unit is disassembled, the base unit sends an alarm message to the platform ◆ Heartbeat package For keeping the base unit and the platform normal connection, the base unit transmits the data to the platform according to the fixed time interval. If the base unit does not send information to the platform according to the fixed time interval, the base station and the platform are disconnected. 4the home base unit installation and use Install the SIM card and spare battery for the home base unit Install the card requirements Ensure that your tracker has a working SIM card. Please make sure SIM card has enough credit. Please make sure that the SIM is not locked and do not require a password to operate. If you need to make a phone call back to your location, Please make sure the SIM card is supporting caller ID display ❶ ❷ Battery fixed position SIM card connector Spare battery connector 1、Unscrew the back cover of the device. 2、Install the SIM card, insert the battery cable, fixed the battery. ❸ power cord Mini USB interface antenna 4 3、 screwdriver screw on the back cover, and then install the antenna Fix the home Base unit ❶ ❷ fixed magnet Connect with power 1、 the foundation of the home base unit with screws fixed to the wall and put the magnet into the specified location 2. The home base unit is screwed to the foundation and Connect with power. Schematic diagram of the home base unit operation (always in wireless transmit mode) Platform The Home Base Unit When the location fails, the tracker(1、2、3) uses the WIFI function to search the home base unit. 5 5 Parameters set up Tracker supports APP setup software by smart phone or by sending command via SMS or by pc. 5.1 Change password Description: change user’s password SMS Command:$SMS,******;W001,######;! SMS Command explain:$SMS,default password;W001,new password;! Explain: ******: user password, the range of 6 digits, default password is 000000 ######: new password, the range of 6 digits. Note: please switch to the English input method when you input a command by smart phone; tracker will only accept commands from a user with the correct password. Command will be ignored if with wrong password. Example: $SMS,000000;W001,123456;! Read password:$SMS,000000;R001;! Clear password:$SMS,000000;C001;! 5.2、Set the GPRS server Description: Enable this function SMS Command:$SMS,000000;W002,APN,Username,Password;W003,IP,Port;W005,X;W009,Y;! Explain: APN: Access point name network of range of: 0~29 characters Username: accesses port’ user name range of: 0~29 characters Password: Accesses port’s password range of: 0~29 characters IP: server’ IP address range of: 0~29 characters Port: server’s port range of: 0~65535 range of: 0~2 0:means disable GPRS function, 1:means upload by TCP, Y: GPRS upload mode 2:means upload by UDP default is 0 6 Example:$SMS,000000;W002, cmnet,;W003,192.168.1.1,8088;W005,1;W009,1;! Read tracking regulary by GPRS: $SMS,000000;R002;R003;R005;R009;! Clear tracking regulary by GPRS: $SMS,000000;C002;C003;C005;C009;! FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. To assure continued compliance, any changes or modifications not expressly approved by the party. Responsible for compliance could void the user’s authority to operate this equipment. (Example- use only shielded interface cables when connecting to computer or peripheral devices). This device complies with part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference. FCC Radiation Exposure Statement: The equipment complies with FCC Radiation exposure limits set forth for uncontrolled enviroment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Author : toby81818 Create Date : 2017:03:10 17:45:23+08:00 Modify Date : 2017:03:31 10:50:30+08:00 XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2017:03:31 10:50:30+08:00 Format : application/pdf Title : Microsoft Word - S921.doc Creator : toby81818 Producer : Acrobat Distiller 11.0 (Windows) Document ID : uuid:f5dc524e-08aa-47cb-acdd-b68c3597ead0 Instance ID : uuid:abfe1965-05c4-4143-8d1f-cecb0a785670 Page Count : 7EXIF Metadata provided by EXIF.tools