OWNER’S AND
OPERATOR’S MANUAL
SOUND PROOF DIESEL ENGINE
GENERATOR / WELDER

DGW311DM
DGW311L
Water-cooled 4 Cycle Diesel Engine

Table of Contents
1. Safety Guidelines
2. Specifications
3. Use
4. Parts
5. Equipment
5-1. ECO Welding (DGW311DM only)
5-2. Monitor Lamp
5-3. Earth Leakage Breaker
5-4. Slow-Down
6. Initialization and Pre-check
6-1. Checking Engine Oil
6-2. Checking Coolant/Water
6-3. Checking Fuel
6-4. Checking Fuel, Engine Oil, and
water Leakage
6-5. Checking Battery
7. Operation
7-1. Initializing/Preparation
7-2. Stopping Generator/Welder
8. Welding Operation
8-1. Selection – Welding Cable
8-2. Polarity
8-3. Connection – Welding Cable
8-4. Duty Cycle
8-5. Welding
9. Generator Operation
9-1. Output Range
9-2. Output Limitation
9-3. Operation
10. Simultaneous Use of Welding and
Generating
11. Checking and Maintenance
12. Long-term Storage
13. Troubleshooting
14. Engine Wiring Diagram
15. Generator Wiring Diagram

Page
2
5
6
6
7
7
8
9
11
11
11
12
13
14
14
14
14
16
16
16
17
17
18
18
19
19
21
22
23
24
27
28
30
31

CAUTION : Do not operate the Generator/Welder, or any other appliance,
before you have read and understood the instructions for use.

Introduction
Thank you for purchasing Shindaiwa Sound Proof Diesel Engine Generator/Welder.
z This user manual was created to ensure the safe operation of this equipment. Therefore, the
manufacturer of this equipment strongly recommends that the user follow the instructions herein, to
avoid unnecessary accidents and repairs.
z Please operate this equipment after thoroughly reviewing and understanding the contents of this
manual.
z Please attach this manual, if the equipment will be sub-leased.
z Please store this manual near the equipment for easy reference.
■Following convention will be used throughout the manual to indicate the degree of
cautions.
Danger
Can cause severe injuries or death.
Caution



Can cause minor injuries or damage to the equipment or other properties.
Other types of caution

z Even some of the items noted in 『

Caution 』 may lead to severe injuries. Please read all

items and follow all the safety guidelines.

1

1. Safety Guidelines

Danger : Suffocation from exhaust fume
z Exhaust fume from the engine contains many elements harmful to human. Do not operate this
equipment in poorly ventilated area, such as inside a room or in a tunnel.

Danger : Electric Shock
z Do not touch the output terminals during operation.
z Do not insert metal objects (such as pin or wire) into plug-in receptacles.
z Do not touch wiring or electric parts inside the equipment during operation.
z Before connecting or disconnecting a load cable from output terminals, always turn the circuit
breaker to OFF position.
z Before connecting or disconnecting a welding cable from output terminals, stop the engine, and
remove the engine key.
z Before performing any equipment check or maintenance, stop the engine, and remove the engine
key. A person performing the check or maintenance should always keep the key.

Danger : Burns
z Do not open the radiator cap while operating this equipment or immediately after stopping the
equipment, to avoid sustaining burns from hot vapor.

Danger : Injuries
z Close all doors and place locks during operating this equipment, to avoid injuries by unintentionally
touching cooling fan and fan belt.

Caution : Suffocation from exhaust fume
z Do not point the exhaust fume toward pedestrians or building.

Caution : Suffocation from welding fume
z Be sure to wear a fume proof mask in operation, because welding fume contains poisonous gas
and dust. Pay attention to the airflow direction and sufficient ventilation also in order to prevent
from inhaling the fume.

Caution : Injuries to eyes and skin
z Be sure to wear spark protection glass(es), long-sleeve shirts, gloves, etc. in order to protect eyes
and skin from harmful spark in welding.
z Battery fluid contains diluted sulfuric acid. Avoid contact with eyes, skin or on clothing. If the acid
comes in contact, especially with eyes, flush with a lot of water, and contact to your physician
immediately.

2

Caution : Electric shock
z Do not flush water onto the equipment nor operate it in the rain.

Caution : Explosion
z When the liquid level is below the LOWER level, never use the equipment nor recharge the battery.
z Battery may emit some combustible gas, so keep it away from fire and sparks.

Caution : Fire
z The equipment uses Diesel fuel as a fuel. When refueling, always stop the engine and keep away
from fire. Moreover, always wait until the engine cools down before refueling.
z Always wipe any drip of Diesel fuel or lubrication oil. Do not use this equipment when a leak is
found. Repair the equipment before use.
z Temperature around muffler and exhaust can get extremely high. Keep any inflammable items
(such as fuel, gas, paint, etc.) away from the equipment.
z Keep any inflammable items and easily burning items away from the place in welding, because
welding splashes spatters.
z Always operate this equipment on flat surface and, at least 1 meter away from any objects (wall,
box, etc.).
z Do not connect AC output to any indoor wiring.
z Always wait until the equipment cools down, before placing any covering materials for storage.

Caution : Burns
z Do not touch the engine and muffler during operation and immediately after stopping the equipment, for the temperature can reach extremely high.
z When checking engine oil or changing oil, always stop the engine, and wait until the engine cools
down. If you open either the oil gauge or the oil filter cap during operation, hot oil may cause some
injury.
z Be sure to wear leather gloves, apron, shoe covers, eye protection glass(es) (mask), safety shoes,
safety cap, and long sleeve shirts, because welding splashes spatters.

Caution : Injuries
z When lifting the equipment, always use a lift hook. Do not lift a handle, for it may cause equipment
to drop due to handle breaking off.
z Always place the equipment on a flat and stable surface, to keep the equipment from sliding. Be
sure to lock the wheels for the wheeled models.
z When starting the engine, turn off the connected equipment and set the circuit breaker to OFF position.
z Do not move the equipment during operation.
z When performing equipment check and maintenance, always stop the engine.
z Do not operate the equipment, if the equipment is being modified or if the parts are removed.

3

„ Location of Warning labels
When the warning labels become unreadable or damaged, place new labels on the appropriate
locations, as specified in the following figure.
When ordering the label, use the following part numbers.
① Suffocation from exhaust fume

(No. 19402-00194 )

② Suffocation from welding fume

(No. 19402-00195 )

③ Electric shock

(No. 19402-00192 )

④ Electric shock

(No. 19402-00193 )

⑤ Injuries

(No. 19402-00199 )

⑥ Burns

(No. 19402-00201 )

⑦ Burns

(No. 19402-00200 )

⑧ Fire

(No. 19402-00166 )

DGW311DM

DGW311L 〔-(W)220B〕

DGW311L

4

〔-(W)380A, -(W)400A, -(W)415A〕

2. Specifications
Model

DGW311DM

DGW311L

-(W)220B
Generating Method

-(W)220B

Rated Current

(A)

280

260

Rated Voltage

(V)

31.2

30.4

(min )

3600

3000
MAX 85

Current Adj. Range (A)
Welding Rod

Current Adj. Range (A)
Welding Rod

Welding Rod

30-160

ECO

2.0-4.0

(Ф )
Single

(Ф )

Current Adj. Range (A)

Dual

85-310

45-310

35-280

2.6-6.0

2.0-6.0

2.0-6.0

45-160
2.0-4.0

(Ф )

Phase

3-Phase/1-Phase

AC Generator

Rated Voltage

(V)

220/110

Frequency (Hz)

380/220

400/230

60

Rated Output

(kVA)

Rated Speed

-1

50

3-Phase

10

1-Phase
(min )

Power Factor

6

8

3600

3000
3-Phase: 0.8 / 1-Phase: 1.0

Rating

Continuous

Model

Yanmar: 3TNE68-USW2

Type

Vertical, Water-cooled 4-Cycle Diesel Engine

Displacement (L)
Rated Output

(kW(PS)/min-1 )

0.784
15.1(20.5)/3600

Fuel

12.9(17.5)/3000

Diesel Fuel(ASTM No.2-D) or Equivalent

Lubricant Oil

API Class CD or Higher

Lubrication Oil Volume (L)

3.5

Cooling Water Volume (L)

3.1

Starting Method

Starter Motor

Battery

46B24L

Fuel Tank Capacity (L)

37

Length (mm)
Width

1428 (Bonnet Length 1293)

(mm)

700

Height (mm)

Dry Weight

-(W)415A

50
-1

No Load Voltage (V)

Output Change

Welding Generator

Rated Speed

Engine

-(W)400A

Brushless, Rotating Field, Synchronous AC Generator

Duty Cycle (%)

Dimension

-(W)380A

760 (870 with wheels)

(kg)

370 (380 with wheels)

5

415/240

3. Use
z Arc Welding
z Power Source for Electric Tools and Home Appliances
z Power Source for Lighting
Caution : Damage to the equipment or other properties
z The equipment is designed for the above purposes only. Do not use it for the other purpose. When
it will be used for the equipment with the microcomputer control or for the ultra-precision devices,
the load may be malfunctioned.

4. Parts

DGW311DM
CURRENT
ADJUSTMENT
DIAL A

CURRENT
ADJUSTMENT
DIAL B
SLOW-DOWN SWITCH

CIRCUIT BREAKER

STARTER SWITCH
MONITOR LAMP

3-PHASE VOLT METER
OUTPUT SELECTOR SWITCH

FUEL GAUGE

1-PHASE OUTPUT RECEPTACLE
HOUR METER
WELDING OUTPUT TERMINAL A

WELDING OUTPUT TERMINAL B
1-PHASE OUTPUT TERMINAL

EARTH GROUNDING TERMINAL

3-PHASE/1-PHASE
OUTPUT TERMINAL

BONNET GROUNDING TERMINAL

DGW311L 〔-(W)220B〕
CURRENT ADJUSTMENT DIAL
CIRCUIT BREAKER
SLOW-DOWN SWITCH
STARTER SWITCH
3-PHASE VOLT METER
MONITOR LAMP
1-PHASE OUTPUT RECEPTACLE

FUEL GAUGE

EARTH GROUNDING TERMINAL

HOUR METER

3-PHASE/1-PHASE OUTPUT TERMINAL
WELDING OUTPUT TERMINAL
1-PHASE OUTPUT TERMINAL
BONNE GROUNDING TERMINAL

6

DGW311L 〔-(W)380A, -(W)400A, -(W)415A〕

CURRENT ADJUSTMENT DIAL
CIRCUIT BREAKER

SLOW-DOWN SWITCH

3-PHASE VOLT METER

STARTER SWITCH
MONITOR LAMP
FUEL GAUGE

EARTH GROUNDING TERMINAL

HOUR METER

3-PHASE/1-PHASE OUTPUT
TERMINAL (U,V, W,O)

WELDING OUTPUT TERMINAL

BONNET GROUNDING TERMINAL

DGW311DM

DGW311L

SIDE DOOR

AIR CLEANER

FUSE

RADIATOR
OIL PLUG,
ENGINE OIL FILLER
OIL GAUGE

BATTERY

RESERVOIR TANK
FUEL LEVER/STRAINER
OIL FILTER
OIL DRAIN PLUG

FUEL INLET

WATER/COOLANT DRAIN PLUG
FUEL DRAIN PLUG

MUFFLER

LIFTING LUG

HANDLE

HANDLE

EXHAUST OUTLET

TOP PLATE

5. Equipment
5-1 ECO Welding (DGW311DM only)
The equipment is incorporated in ECO welding features that are aimed at performing the lower
noise, the lower fuel consumption and the lower gas emission than conventional models.
When you turn the selector switch to ECO, you will be able to weld with Max. 4.0mmφwelding
rod at the Slow-Down speed.
7


z When welding is performed, do not turn the output selector switch, which causes the burnout
of the switch.
z ECO is designed for welding only. The circuit breaker trips when ECO is used for AC power
supply.

5-2 Monitor Lamp
The equipment is equipped with monitoring function of oil
pressure, battery charge and water/coolant Temperature.
When it is started by the starter switch from STOP to RUN

OIL PRESSURE MONITOR LAMP

under normal condition, Oil Pressure and Battery lamps will

BATTERY CHARGE MONITOR LAMP

flash, and then the lamps will go off, immediately after the

COOLANT/WATER TEMPERATURE
MONITOR LAMP

engine starts.
When abnormality is detected either in water temperature or in oil pressure, the corresponding
monitor lamp will flash, and the automatic shutoff shall be engaged to the engine.
When the automatic shutoff is engaged, turn the starter switch to STOP position, and then restart
the engine. In the event the automatic shutoff is engaged next time, check all parts of the
corresponding alarm.

5-2.1 Oil Pressure Monitor Lamp
Danger : Injuries
z Close all doors and place locks during operating this equipment, to avoid injuries by unintentionally touching cooling fan and fan belt.
Caution : Burns
z Do not touch the engine and muffler during operation and immediately after stopping the
equipment, for the temperature can reach extremely high.
z When checking engine oil, always stop the engine, and wait until the engine cools down. If
you open either the oil gauge or the oil filter cap during operation, hot oil may cause some
injury.
When the engine oil pressure drops during operation, the oil pressure monitor lamp will flash,
and the automatic shutoff will be engaged.
When this occurs, check the engine oil level, and replenish to the maximum level if needed.

z The engine oil pressure monitor cannot detect the degradation of engine oil itself. Please
check the engine oil periodically, and change if needed. (Refer to No. 11. Maintenance.)

5-2.2 Battery Charge Monitor Lamp
When the battery is unable to be charged during operation, the battery charge monitor lamp will
flash and the automatic shutoff will be engaged. In the event it will happen, consult with the authorized distributor or our engineering section.

z The battery charge monitor cannot detect the degradation of battery life nor the battery fluid
8

level. Check the battery fluid level periodically. (Refer to No. 6-5 Checking Battery)

5-2.3 Coolant/Water Temperature Monitor Lamp
Danger : Injuries
z Close all doors and place locks during operating this equipment, to avoid injuries by unintentionally touching cooling fan and fan belt.
Danger : Burns
z Do not open the radiator cap while operating this equipment or immediately after stopping the
equipment, to avoid sustaining burns from hot vapor.
Caution : Burns
z Do not touch the engine and muffler during operation and immediately after stopping the
equipment, for the temperature can reach extremely high.
When the water temperature rises abnormally, the coolant/water temperature monitor lamp will
flash, and the automatic shutoff will be engaged.
When this occurs, check the coolant/water reservoir tank, and replenish if needed. (Refer to No.
6-2 Checking coolant/water temperature.) If the water level is normal there may be a possibility
of overloading and always use equipment within the rated amperage.

z Check the fuse next, after oil pressure, battery charge and water temperature will be found
normal when you have checked them in the first place. If the fuse is burned out, consult with
our authorized distributor or our engineering section, because there may be an abnormality
of electric/electronic parts or wiring and repairing may be required.

5-3. Earth Leakage Breaker
Danger : Electric Shock
z All the grounding terminals must be grounded. If one of them is not grounded, human body
may get a serious electric shock by leaked current.
z Even though all the terminals of the loads have been grounded to the earth, the earth
grounding terminal and the outer bonnet (canopy) grounding terminal should be grounded to
the earth.
z Grounding should be made after the engine is stopped.
z Whenever the earth leakage breaker has activated, you should always repair the leaking
place first of all.

z The earth leakage breaker activates only for AC power supply.
z The circuit breaker trips to protect the loads, whenever AC power is used if the selector
switch is in the ECO position. (DGW311DM only)

The equipment is provided with the earth leakage breaker to detect any leakage arisen due to
such the troubles as insulation failure of the load while the generator is running and to cut off the
circuit for protection against any accident such as electrical shock resulting from the trouble.
9

The specifications of the earth leakage breaker :
z

Rated Sensitive Current: 30mA (or below) (Grounding resistance: 500Ω or below)

z

Sensitive time: Within 0.1second

5-3.1 Grounding Work
The qualified electrician should perform the grounding work of the following 3 points (500Ω or
below).
z

The earth grounding terminal in the output terminals

z

The Outer Bonnet (Canopy) of the generator

z

The Outer Bonnet of the load


z In the event you cannot ground the generator to the earth, consult with the authorized distributor or our engineering section.

DGW311DM

DGW311L

EARTH GROUNDING TERMINAL

EARTH GROUNDING TERMINAL

BONNET GROUNDING
TERMINAL

BONNET GROUNDING
TERMINAL

GROUNDING ROD

GROUNDING ROD

5-3.2 Operation Check
Before operating the generator, check always if the device can work.

RESET BUTTON

EARTH LEAKAGE
INDICATION LAMP

① Turn the starter switch from STOP to Run.
② Turn (Push-up) the circuit breaker (lever) to ON position.
③ Push the test button. (When the button is pushed, the earth
leakage indication lamp turns ON and the circuit breaker is positioned in the middle of ON and OFF positions, the device can
TEST BUTTON

work normal.)
④ Push the reset button. (The earth leakage indication lamp (red)
turns OFF subsequently.)
⑤ Turn (push down) the circuit breaker (lever) to OFF position.
⑥ Restore the switch to STOP.


z In the event you cannot complete every step of the above procedure to the end, the device is
out of order. Consult with our authorized distributor or our engineering section to repair.
10

z When the engine is to start, there may be a case that the engine will not start unless the
starter switch is restored to STOP once.

5-3.3 The Earth Leakage Breaker has activated
When the earth leakage breaker has activated, the earth leakage indication lamp turns ON and
the breaker (lever) trips to the middle of ON and OFF positions. In the case, stop the engine
promptly and find the leakage point to repair. After repairing leakage point(s), proceed with the
following restoration steps.
① Push the reset button or stop the engine.
② Restore (push down) the breaker (lever) to OFF position.
By the above procedures, you can reset the breaker to ON position.

z When the breaker trips to the middle but the lamp does not turn RED simultaneously, the
cause is Over-loaded or the output selector switch is positioned to ECO. Restore as per the
procedures No. 9-3 Operation.

5-4 The Slow-Down Feature
The Slow-Down feature is to set the engine speed low automatically (in about 8 seconds)for the
purpose of reducing noise and fuel consumption, whenever welding operation or electric supply
is not performed.
In the case of using the Slow-Down feature, turn the Slow-Down switch to ON. The engine
automatically moves to high speed, when welding operation or electric supply starts.
Caution : Damage to the equipment or other properties
z Turn always the Slow-Down switch to OFF, when the load is incorporated with a electromagnetic switch.

z When the load of less than 0.5A is connected to use, the Slow-Down feature does not function sometimes. Therefore, turn the switch to OFF.
z When welding operation or electric supply is used intermittently, turn the switch to OFF.
z When the output selector switch is positioned to ECO, the engine does not turn to high speed.
(DGW311DM only)

6.

Initialization and Pre-check
Caution : Fire・Burns・Injuries
z When checking engine, always stop the engine, and keep away from fire. Wait until the engine cools down, before performing any checks.
OIL GAUGE (YELLOW)

6-1 Checking Engine Oil

OIL FILLER

When checking for engine oil, be sure to keep the equipment
leveled, and insert the oil gauge all the way in.
Prior to starting the equipment, make sure to fill the engine oil
to the HIGH level through the oil inlet.
SIDE DOOR

11

OIL PLUG (YELLOW)


z If the equipment is not leveled, you cannot obtain accurate oil level.
z Do not overfill (over H line) the engine oil. The excessive volume of engine oil may damage
the engine (inside the cylinders)
■

Selecting proper engine oil
Use the engine oil for Diesel engine in proper viscosity, in
compliance with the ambient temperature.

UPPER LIMIT (H)

REQUIRE LEVEL
LOWER LIMIT (L)


z Use the API class CD grade or higher.

Viscosity and Temperature
Temperature

Over +20℃

+10 - +20℃

-10 - +40℃

Viscosity

SAE30

SAE20

SAE10W/30

6-2 Checking Coolant/Water
Danger : Injuries
z Close all doors and place locks during operating this equipment, to avoid injuries by unintentionally touching cooling fan and fan belt.
Danger : Burns
z Do not open the radiator cap while operating this equipment or immediately after stopping the
equipment, to avoid sustaining burns from hot vapor.
Caution : Burns
z Do not touch the engine and muffler during operation and immediately after stopping the
equipment, for the temperature can reach extremely high.
Check to see if the coolant/water level is between FULL and LOW levels in the reservoir tank. If
the coolant/water is below the LOW level, fill the tank and the radiator accordingly.

6-2.1

Filling to the Reservoir Tank

① Take out the reservoir tank to remove the cap.
② Fill up the reservoir tank to the FULL level.

SIDE DOOR

CAP

③ Install the cap back and tighten, and reinstall the tank to
the equipment.
6-2.2

Filling to the Radiator

RESERVOIR TANK

① Remove the top plate.
② Remove the radiator cap.
12

③ Fill up the radiator up to the top.
TOP PLATE

④ Install the cap back and tighten.
⑤ Reinstall the top plate.

z Use soft water, such as tap water.

RADIATOR CAP

z If the ambient temperature is near freezing, use Long

WATER FILLER

Life Coolant (LLC) (30% mixture LLC is filled when
shipped from factory).
z Mixture ratio of the coolant should be between 30 to
45%, depending on the outside temperature.
z Use the same LLC in identical mixture ratio to the resRESERVOIR
TANK

ervoir tank.
z Replace LLC at every year or 1000 hours.

Mixture Ratio (for reference only): ℃
Lowest Ambient
-15℃
-20℃
Temperature
Mixture Ratio
30%
35%

-30℃
45%

6-3 Checking Fuel
Caution : Fire
z Always wipe any drip of fuel. Do not use this equipment when a leak is found. Repair the
equipment before use.
Check for the fuel level in the tank. Add if necessary.

z Use Diesel fuel, ASTM D975 No.2-D in the event ambient
temperature reaches down to -5℃.

TANK CAP

z The engine is designed to use either No.1-D or No.2-D
Diesel fuel. However, for better economy, use No. 2-D Diesel Fuel whenever possible. At the temperature less than
-7℃(20F), No.2-D fuel may pose operating problems (see
“Cold Weather Operation” which follows). At colder tem-

FUEL INTAKE
FUEL STRAIN NET

peratures, use No.1-D fuel (if available) or use a “winterized” No.2-D (a blend of No.1-D and No.2-D).
This blended fuel is usually called No.2-D also, but can be used in colder temperatures than
No.2-D fuel, which has not, been “winterized”. Check with the services stations operator to
be sure you can get the properly blended fuel.
z Always use the Diesel fuel strainer.
z Fill the fuel tank slightly less than the FULL tank.

13

6-4 Checking Fuel, Engine Oil and Water Leakage
Caution : Fire
z Always wipe any drip of Diesel fuel or oil. Do not use this equipment when a leak is found.
Repair the equipment before use.
Be sure to check for any fuel leak at the hose connection, and oil and coolant/water by opening
side doors. When checking for any fuel leak, open a fuel lever and be sure to close the fuel lever
after checking.

6-5 Checking Battery
Caution : Injuries to eyes and skin
z Battery fluid contains diluted sulfuric acid. Avoid contact with eyes, skin or clothing. If the acid
comes in contact, especially with eyes, flush with a lot of water, and contact your physician
immediately.
Caution : Explosion
z When the liquid level is below the LOWER level, never use the equipment nor recharge the
battery.
z Battery may emit some combustible gas, so keep it away from fire and sparks.
① Check the fluid level. If the level is near or lower than the

TERMINAL

LOWER level, add distilled water until the fluid level reaches
the UPPER level.
UPPER
LEVEL

② Make sure that the battery cables are firmly secured to the
posts. Tighten the clamps if necessary.

LOWER
LEVEL


z Check the hydrometer of the battery fluid. If it falls below 1.23, the battery requires recharging. Please consult with our authorized distributor or our engineering section.
INS-CAP

„ Replacing battery

- TERMINAL
+ TERMINAL

① Remove the clamp and cable from negative (-) post in
the battery. (Remove always negative side first)
② Remove the hold-down clamp from the battery.
③ Remove the clamp and cable from positive (+) post in

HOLD-DOWN
CLAMP

the battery.
④ Remove the battery from the seat.

BATTERY

※ Reinstall a new battery in the reverse order. (Install always the cable to the positive (+) post
in the new battery first.)

z Use the following battery.
46B24L

7. Operation
7-1 Initializing/Preparation
14

Danger : Suffocation from exhaust fume
z Exhaust fume from the engine contains many elements harmful to human. Do not operate
this equipment in poorly ventilated area, such as inside a room or in a tunnel.
Caution : Suffocation from exhaust fume
z Do not point the exhaust fume toward pedestrians or building.
Caution : Fire
z Temperature around muffler and exhaust can get extremely high. Keep any inflammable
items (such as fuel, gas, paint, etc.) away from the equipment.
z Always operate this equipment on flat surface and, at least 1 meter away from any objects
(wall, box, etc.)
Caution : Injuries
z Always place the equipment on flat and stable surface, to keep the equipment from sliding.
Be sure to lock the wheels for the wheeled models.
z When starting the engine, turn off the connected equipment and set the circuit breaker to
OFF position.
① Turn the circuit breaker to OFF position.
② Turn the fuel lever to OPEN.
③ Turn the Slow-Down switch to ON.
FUEL LEVER

④ When the temperature is below 5℃,turn the starter
switch to PREHEAT. The preheating lamp flashes 15

CLOSE

seconds. The lamp comes off when the PREHEAT finOPEN

ishes.
⑤ Turn the starter switch to START to start the engine by the
starter motor.

z Do not drive the starter motor for more than 15 seconds successively.
z If you need to restart, wait for 30 seconds or more before retry.
⑥ Release the starter switch, as soon as the engine is started.

z Once the engine is started, do not turn the starter switch to START.
⑦ Make sure the frequency to the monitor on the control panel.
⑧ Keep the engine idle for about 5 minutes.

DGW311DM

DGW311L
CIRCUIT BREAKER

CIRCUIT BREAKER

STARTER SWITCH

SLOW-DOWN SWITCH

STARTER SWITCH

SLOW-DOWN SWITCH
PREHEAT LAMP

15

PREHEAT LAMP

„ Restart after stopping due to fuel shortage
This equipment is equipped with automatic air vacuuming feature. Therefore, even though the
engine stops due to running out of fuel, you can restart the engine easily by the following steps.
① Turn the starter switch to STOP.
② Fill the fuel.
③ Turn the Slow-Down switch to ON.
④ Turn the starter switch to RUN.
⑤ Turn the starter switch to START and drive the starter motor.

z Do not drive the starter motor for more than 15 seconds successively.
z If you need restart, wait for 30 seconds or more before retry.
⑥ Release the starter switch, as soon as the engine started.

z Once the engine is started, do not turn the starter switch to START.
⑦ Wait for about 1 minute to vacuum the air out.
(The engine speed becomes stable when the air is extracted.)

z

Keep the Slow-Down switch ON unit the air is completely extracted out (unit the engine
speed becomes stable), otherwise the engine may disorder.

7-2 Stopping Generator/Welder
① Turn (Push down) the breaker to OFF.
② Turn the Slow-Down switch to ON.
③ Keep the engine idle (cooling down) for about 5 minutes.
④ Turn the starter switch to STOP.
⑤ After the engine stops, turn the fuel lever to CLOSE.

z When the engine does not stop in spite of turning the starter switch to STOP, turn the fuel
lever to CLOSE, then the engine will stop in a few minutes.
In this case, consult with our authorized distributor or our engineering section and ask to repair.

8. Welding Operation
8-1 Selection – Welding Cable
Select the cable with proper gauge, based on the allowable amperage and distance per the table
shown below.
The welding capacity is reduced if the small gauge cable is used.

z Welding cables should be used unstrained.
z When the welding cables are used in swirl, the welding capacity is reduced.
16

Welding Current

Size of Cable (Unit: mm2)
Return Length 20m 30m

40m

60m

80m

100m

300A

30

38

50

80

100

125

250A

22

30

38

60

80

100

200A

22

30

30

50

60

80

150A

22

22

22

38

50

60

100A

22

22

22

30

30

38

8-2 Polarity
There are two kinds of welding output terminals, 『+』and 『-』.
Select the polarity according to the operation, referring to the table below.

z Follow the instruction of the welding rods, the polarity of which is specified.
Application

Connection

Normal Polarity

General Welding,
such as construction

Plus to the Earth (Material)
Minus to holder (Rod)

Reverse Polarity

Thin Plate, Build up
Welding, Stainless
Steel

Plus to holder (Rod)
Minus to the Earth (Material)

8-3 Connection – Welding Cable
Danger : Electric Shock
z Before connecting or disconnecting a welding cable from welding output terminals, stop the
engine, and remove the engine key. A person performing should always keep the key.
① Stop the engine.
WELDING CABLE

② Connect a welding cable to a crimping terminal and a welding
rod holder, and connect the other cable to a crimping terminal

WELDING ROD

CRIMPING

HOLDER

TERMINAL

and a material holder.
③ Connect the welding cables to the output terminals.
In terms of DGW311DM, connect cables to the welding output
terminals, referring to the table below.
MATERIAL HOLDER

ECO (Single)

Single

Dual

Welding Rod
φ2.0 – φ4.0

Welding Rod
φ2.6 – φ6.0

Welding Rod
φ2.0 – φ4.0

Welding Output Terminal A

Welding Output Terminal A

Welding Output Terminal A and
Welding Output Terminal B

④ Close the output terminal cover, after finishing connections, and fix the cover with bolts.

z Be sure to crimp a crimping terminal to a cable and connect the cable to welding output ter17

minal. Otherwise, welding output terminals may burn out by the heat caused by insufficient
connections.
z Do not use a cable without a crimping terminal. If you use the cable, the insulation is peeled
off partly, to bind to an output terminal, the output terminal may burn out by the heat caused
by insufficient connections and also a bare part of the cable may touch the bonnet to shortcircuit.

8-4 Duty Cycle
Duty cycle means the welding time ratio for 10 minutes. This equipment is the rated duty cycle is
50%, namely, the welding time is 5 minutes or less. Be sure to take 5 minutes recess after 5
minutes welding.

z The equipment may be damaged due to overheat, if welding more than 5 minutes successively or short time recess after the welding.

8-5 Welding
Caution : Suffocation from welding fume
z Be sure to wear a fume proof mask in operation, because welding fume contains poisonous
gas and dust. Pay attention to the airflow direction and sufficient ventilation also in order to
prevent from inhaling the fume.
Caution : Injuries to eyes and skin
z Be sure to wear spark protection glass(es)(Refer to the table below), long-sleeve shirts,
gloves, etc. in order to protect eyes and skin from harmful spark in welding.

Standard for Spark Protection Glass (Japan Industrial Standard)
Light Shielding Degree No.

Welding Current (A)

7

8

9

30-75

10

11

12

76-200

13
201-400

Caution : Fire
z Keep any inflammable items and easily burning items away from the place in welding, because welding splashes spatters.
Caution : Burns
z Be sure to wear leather gloves, apron, shoe covers, eye protection glass(es)(mask), safety
shoes, safety cap and long sleeve shirts, because welding splashes spatters.

z Never turn the output selector switch during welding, because it causes burnout of the switch.
(DGW311DM only)

8-5.1 DGW311DM
The equipment can be welding by 2 persons simultaneously.
Each person can adjust the welding current individually.
The current adjustable range by the current adjustable dial depends on the position each of the
18

welding output selector switch (『ECO』,『Single』and『Dual』).
Welding Current Adjustable Range
Selector Position Current Adjustable Range
ECO

30-160A

φ2.0-4.0

Single Use

85-310A

φ2.6-6.0

Dual Use

45-160A

φ2.0-4.0

Single
Dual

Welding Rod

After the engine is started (Refer to No. 7.1 Initializing/Preparation), operate as per the procedures in the following table.

CURRENT ADJUSTMENT
DIAL A

CURRENT ADJUSTMENT
DIAL B

OUTPUT SELECTOR
SWITCH
WELDING OUTPUT
WELDING OUTPUT
TERMINAL B
TERMINAL A

Procedure

Welding Operation Procedure
Operation
ECO (Single)
Welding Rod
φ2.0-φ4.0

Single Welding
Welding Rod
φ2.6-φ6.0

Dual Welding
Welding Rod
φ2.0-φ4.0

『ECO』

『SINGLE』

『DUAL』

①

Selector

②

Current
Adjustment

Current Adjust.
Dial A

Current Adjust.
Dial A

Current Adjust.
Dial A + B

8-5.2 DGW311L
① Start the engine. (Refer to No. 7.1 Initializing/Preparation)
② Adjust the current by the current adjustment dial.
Welding Current Adjustable Range
Current Adjustable Range
Welding Rod
50Hz
60Hz
-(W)380A,-(W)400A,-(W)415A

35-280A

-(W)220B

45-310A

φ2.0-φ6.0

9. Generator Operation
9-1 Output Range
9-1.1 DGW311DM-(W)220B, DGW311L-(W)220B
9-1.1.1

3-Phase 220V Output – Terminals

Maximum output from the terminals (U, V, W) is 10kVA.

19

CURRENT ADJUSTMENT DIAL
BREAKER

CURRENT ADJUSTMENT

9-1.1.2

1-Phase 220V Output – Terminals (using the terminals only)

1-Phase 220V Output is available, using the 3-phase output terminals. Maximum output available
for the one set of the terminals is 6kVA but the total output for the 3 sets is 8kVA, which please
note.

9-1.1.3

1-Phase 110V Output – Receptacles & Terminals

1-Phase 110V Output is available through 2 receptacle sets and one terminal set.
Maximum output per one receptacle is 1.5kVA and one terminal set is 3kVA. The total output for
the receptacles and the terminal set is 6kVA.

9-1.2 DGW311L-(W)380A, DGW311L-(W)400A, DGW311L-(W)415A
9-1.2.1

3-Phase Output – Terminals

Maximum output from the terminals (U, V, W) is 10kVA.
DGW311L
Output
voltage

-(W)380A

-(W)400A

-(W)415A

380V

400V

415V

9-1.2.2 1-Phase Output – Terminals
1-Phase Output is available, using the 3-Phase output terminals. Maximum output available for
the one set of the terminals is 6kVA but the total output for the 3 sets is 8kVA, which please note.

DGW311L
Output
voltage

20

-(W)380A

-(W)400A

-(W)415A

380V

400V

415V

9-1.2.3

1-Phase Output – Terminals

1-Phase Output is available, using the 3-Phase output terminals and the other terminal (O).
Maximum output available for the one set of terminals is 3kVA but the total output for 3 sets is
8kVA, which please note.

DGW311L
Output
voltage

-(W)380A

-(W)400A

-(W)415A

220V

230V

240V


z When using 1-Phase output, connect the loads evenly to each terminal set as much as possible.

9-2 Output Limitation
Please refer to the following table, because electric tools and home appliances cannot be judged
only by the rated output or the power consumption due to the efficiency and characteristic of the
components.

DGW311DM-(W)220B, DGW311L-(W)220B :
Applicable Load (For reference purpose only)
Capacity (kW)
1-Phase 110V

Loads

Receptacle
1 unit

Terminal
1 set

(60Hz)

1-Phase 220V
Receptacle
& Terminal
Total

Terminal
1 set

Terminal
3 sets
Total

3-Phase
220V
Terminal

Electric Bulb, Heater, etc.

1.5

3.0

6.0

6.0

8.0

-

Electric Tools (Series Motor),
etc.

0.7

1.5

3.0

3.0

4.0

-

Mercury Bulb (High Power
Factor Type)

0.6

1.2

2.4

2.4

3.2

-

Submersible Pump, Compressor, etc. (Induction Motor)

0.6

1.2

2.4

2.4

3.2

4.0

21

DGW311L-(W)380A, DGW311L-(W)400A, DGW311L-(W)415A :
Applicable Load (For reference purpose only)
Capacity (kW)
Loads

Electric Bulb, Heater, etc.

1-Phase
(O & U, V, W)
Terminal
Terminal
1 set
3 sets
Total
3.0
6.0

(50Hz)

1-Phase
(U, V, W)
Terminal
Terminal
1 set
3 sets
Total
6.0
8.0

3-Phase
(U, V, W)
Terminal

-

Electric Tools (Series Motor),
etc.

1.5

3.0

3.0

4.0

-

Mercury Bulb (High Power
Factor Type)

1.2

2.4

2.4

3.2

-

Submersible Pump, Compressor, etc. (Induction Motor)

1.2

2.4

2.4

3.2

4.0

※ Series Motor: Motor with brush
※ Induction Motor: Brushless Motor
※ The value described is 『OUTPUT』 for Induction Motor loads and 『POWER CONSUMPTION』 for the other equipment.

z Be sure to use the frequency designated in the equipment incorporated in mercury lamp or
induction motor.
z The load incorporated in motor may require bigger power than the rated power consumption.
Therefore, consult with our authorized distributor or our engineering section to clarify.
z When connecting 2 or more sets to use, start the load one by one, not to start them simultaneously.
z When switching a Mercury bulb ON again, wait for 15 minutes (about) until it cools down.
z A Mercury bulb may flicker sometimes.

9-3 Operation
Danger : Electric Shock
z Before connecting or disconnecting a load cable from output terminals, always turn a circuit
breaker to 『OFF』 position.
z All the grounding terminals must be grounded. If one of them is not grounded, human body
may get a serious electric shock by leaked current. (Refer to『5-3 Earth Leakage Breaker』)
z Grounding should be made after the engine is stopped.
z Whenever the earth leakage breaker activates, you should repair the leaking place first of all.
Caution : Injuries
z Be sure to connect to output terminals or insert a plug to a receptacle, after confirming that all
the switches in the loads are positioned to 『OFF』.

22

Caution : Damage to the equipment or other properties
z In the event using the equipment to computers, microcomputers incorporated loads and precision equipment, there is a possibility for them to be mal-functioned or broken down.

z Be sure to use the power cord with crimping terminal to connect to output terminals.
z Volt meter reads the 3-Phase figures, even if the circuit breaker is positioned to『OFF』, when
the engine is driving.
After the engine starts (Refer to 『7-1 Initializing/Preparation』), operate the equipment as per the
following procedures.
① Turn off the power switch in the load, and then turn the circuit breaker to 『OFF』.
② Connect the load to the output terminals or receptacles.
③ Close the output terminal cover, after finishing connections and fix the cover with bolts.
④ Turn the circuit breaker to 『ON』.
⑤ When finishing the load operation, always turn the circuit breaker to『OFF』.
„ The Circuit Breaker
Caution : Injuries
z Be sure to turn off the power switch in the load when turning the circuit breaker to 『ON』,
when the circuit breaker has activated.
When the electric supply exceeds the rated output (overload), the circuit breaker activates to trip
off in order to shut off the circuit. When the load in operation stops, check the breaker. When the
circuit breaker is positioned intermediary『ON』and『OFF』, check if the earth leakage indication
lamp turns ON or not. In the case the lamp turning ON, refer to 『5-3 Earth Leakage Breaker』. In
the case the lamp NOT turning ON, follow the next procedures to restore the circuit breaker.
① Turn off all the power switches in the loads.
② Turn (Push) down the circuit breaker to『OFF』once and then turn (push) up the circuit
breaker to『ON』.

z Take care for overload, referring to 『9-2 Output Limitation』.
z When the output selector switch is positioned to ECO and AC power is used, the circuit
breaker trips off to shut down the circuit. Stop using AC power and follow the above procedures to restore the circuit breaker. (DGW311DM only)

10. Simultaneous Use of Welding and Generating
The circuit breaker reacts on the AC power supply circuit only. In the simultaneous use of welding
and generating, there sometimes happens overload to the engine.
Refer to the following table and limit the AC power use.

DGW311DM-(W)220B, DGW311L-(W)220B :
Limitation of AC Power Supply in the simultaneous use of welding and generating (60Hz)
23

Welding Output
Welding Rod/Current

AC Power Output
3-Pase Power use only

1-Phase Power Use only

φ2.0mm/50A or below

9.5kVA or below

7.6kVA or below

φ2.6mm/80A

8.6kVA or below

6.8kVA or below

φ3.2mm/120A

7.2kVA or below

5.7kVA or below

φ4.0mm (φ2.0mmx2)/170A

5.2kVA or below

4.1kVA or below

φ5.0mm (φ2.6mmx2)/220A
φ6.0mm (φ3.2mmx2)/280A

3.0kVA or below
0kVA or below

2.4kVA or below
0kVA or below

※ (

) indicates 2-Persons Dual Use. (DGW311DM only)


z The simultaneous use of ECO welding and AC power is not available. (DGW311DM only)

DGW311L-(W)380A, DGW311L-(W)400A, DGW311L-(W)415A :
Limitation of AC Power Supply in the simultaneous use of welding and generating (50Hz)
Welding Output
AC Power Output
Welding Rod/Current

3-Pase Power use only

1-Phase Power Use only

φ2.0mm/50A or below

8.5kVA or below

6.8kVA or below

φ2.6mm/80A

7.6kVA or below

6.0kVA or below

φ3.2mm/120A

6.2kVA or below

4.9kVA or below

φ4.0mm/170A

4.2kVA or below

3.3kVA or below

φ5.0mm/220A
φ6.0mm/260A

2.0kVA or below
0kVA or below

1.6kVA or below
0kVA or below

11. Checking and Maintenance
Danger : Electric Shock・Injuries
z Before performing any equipment check or maintenance, stop the engine, and remove engine key. A person performing the maintenance should always keep the key.
Caution : Fire・Burns
z When checking the engine, always stop the engine, and keep away from fire. Wait until the
engine cools down, before performing any checks.
To optimize the use of this equipment, we recommend the periodical equipment checks and
maintenance based on the following matrix.

z The authorized technicians should perform all checking and maintenance work, except for
the pre-startup checks.
z Request for the maintenance item with ● mark to the authorized distributor or our engineering section.
z This table only covers the simple checks and maintenance for the engine. For more detailed
guide, please refer to the User’s Manual for the engine.
z Always use our genuine replacement parts.

24

1

Use the hour meter as a guide for the operating time.
Checking Time
Checking Items
Startup
Check
Every
Every
Every
At
1000 hrs
200hrs
400hrs
50hrs
Check and Supply Fuel
○

2

Check and Supply Engine Oil

3

Engine Oil Change

1st ○

4

Oil Filter Change

1st ○

5

Check/Add Water/Coolant

6

Water/Coolant Change

7

Clean/Change Fuel Filter

○
nd

2 or
after ○
nd
2 or
after

8

○

○
○ or
one year
○

○

(Clean)

(change)

Drain Water from Fuel Tank

9
10

Check Leakage Fuel・Oil・Water
Check/Add Water Battery

11

Clean/Change Air Cleaner Element
Adjust Tension V-Belt

13

Clean Radiator Fin

14

Change Hose Fuel・Radiator
Change Vibration-Absorbing Rubber
Adjust Engine Valve Clearance
Check/Adjust Injection Nozzle

17

Check/Adjust Injection Pump

2nd or after

○

○

(Clean)
nd
2 or

(change)

after●

●

16

11.1 Oil Change
First Time

○
○

1st ●

12

15

Every
2000 hrs

●

or 2
years

●

●

(Adjust)

(Adjust)

●
●

50 hour mark
Every 200 hours
SIDE
DOOR

① Remove the oil plug.
② Loosen the oil drain plug and allow the oil to drain fully.

OIL
FILLER

③ Reinstall the oil drain plug.
④ Checking the oil level by the oil level gauge, add oil

OIL PLUG (YELLOW)

into the oil filler to fill up to the max level. (3.5 liter Max)
OIL DRAIN PLUG

⑤ Reinstall the oil plug hand tight.

z Refer to 『6-1 Checking Engine Oil』to select engine oil.

11.2 Oil Filter Change
First Time
nd

2

or after

50 hour mark
Every 200 hours

① Drain the engine oil fully, as describe in 『11-1 Oil Change』.
25

② Loosen and remove the oil filter, using an oil filter
wrench.
OIL GAUGE (YELLOW)

③ Smear a little engine oil on the rubber gasket of a new
filter.
④ Screw the new filter into place and tighten it by hand
until the gasket contact the seat. Then, give it additional

OIL FILTER

『1.1/4 Turn』to seat the filter, using an filter wrench.

GASKET

⑤ Supply oil and install the filler cap.

z If an oil filter wrench is not available, contact our authorized distributor or our engineering section.
z Oil Filter Part No.: 119305-35151 (Yanmar)

11.3 Cleaning/Changing Air Filter Element
Clean
Every 200 hours
Replace

Every 400 hours

① Unfasten clips in the cleaner cap and remove the air

AIR CLEANER

cleaner cap.
② Unscrew the wing bolt and remove the air filter element.

SIDE DOOR

③ Clean or replace the air filter element, and reinstall it
in reverse order.

z Clean more frequently, if used in dusty environment.

CLIP

ELEMENT

z Air Filter Element Part No. 121465-12510 (Yanmar)

WING BOLT

„ How to clean air filter element
CLEANER


It may be cleaned by blowing compressed air from the inside.

It should be replaced to a new one.

11.4 Cleaning/Changing Fuel Filter
Clean
Every 200 hours
Replace

FUEL LEVER

Every 400 hours
CLOSE

① Turn the fuel line valve lever to 『CLOSE』.
② Unscrew the retaining ring by turning counterclockwise, and

RETAINING
RING
OPEN

CUP

remove the cup and fuel filter element.
③ Discard any dust or water inside the cup, and clean the filter element by blowing compressed
air. (or replace, if necessary) (When you replace the filter element, be sure to replace a o-ring
26

as well)
④ Reassemble it back.

z Be sure to check for any contaminants on the packing, whenever reinstalling the cup.
z Turn the fuel line valve lever 『OPEN』after assembling, and check for any leak. Confirming
no leak, turn the fuel line valve 『CLOSE』.
z Fuel Element Part No.: 124550-55700 (Yanmar)

11.5 Draining Water from Fuel Tank
Drain Water
Every 200 hours
SIDE DOOR

① Unscrew the fuel drain plug.
② Reinstall the drain plug, after draining the water entirdy.

FUEL DRAIN
PLUG
WATER DRAIN
PLUG

11.6 Changing Coolant/Water
Replace

Every 1 year or 1000 hours

TOP PLATE

① Remove the top plate.
② Remove the radiator cap.
③ Loosen the water drain plug.
④ After draining all the water, reinstall the water drain plug.

RADIATOR CAP

⑤ Remove the reservoir tank and replace all the water.

WATER FILLER

⑥ Install the reservoir tank back, and fill the radiator with
coolant/water up to radiator filler neck. (Total coolSIDE DOOR

ant/water Capacity is 3.1 liter.)
⑦ Reinstall the radiator cap.

CAP

⑧ Install the top plate back.
RESERVOIR TANK

12. Long - Term Storage
Danger : Electric Shock
z Before performing any equipment check or maintenance, stop the engine, and remove the
engine key. A person performing the maintenance should always keep the key.

Caution: Injuries
z Before performing any equipment check or maintenance, stop the engine, and remove the
engine key. A person performing the maintenance should always keep the key.
Caution : Fire・Burns
z When checking engine, always stop the engine, and keep away from fire.
z Temperature around muffler and exhaust can get extremely high. Wait until the engine cools
down, before performing any checks.
27

If the generator/welder will not be used for more than two months, perform the following
maintenance and storage procedures.
① Remove battery.
② Change engine oil.
③ Drain fuel from fuel tank and fuel filter.
④ Clean all parts, cover the generator/welder, and keep it in the storage, away from dust and
humidity.

z Recharge the removed battery once a month.

13. Troubleshooting
Danger : Electric Shock
z Do not operate the equipment, if the equipment or you are wet.
z Before performing any equipment check or maintenance, stop the engine.
Caution : Injuries
z When performing equipment check and maintenance, always stop the engine.
Caution : Fire・Burns
z When checking engine, always stop the engine, and keep away from fire.
z Temperature around engine, muffler and exhaust can get extremely high. Wait until the engine cools down, before performing any checks.
Follow the guideline below, when performing any troubleshooting. If you cannot resolve the
problems by this troubleshooting guide, contact the authorized distributor or our engineering section to request the repair.
Symptoms

Possible Cause

Corrective Actions

Starter motor does not start

1. Weak Battery
2. Dead Battery

1. Recharge Battery
2. Replace Battery

Engine does not start

1. Fuel lever to CLOSE
2. Insufficient Fuel
3. Water or contaminants in fuel

1. Fuel lever to OPEN
2. Replenish fuel
3. Drain water or clean fuel tank,
fuel filter, and water sediments

Engine starts, but stalls imme- 1. Insufficient oil
diately
2. Insufficient coolant/water
Welding Arc is weak

1. Output selector switch is to 『ECO』
or 『DUAL』
2. Wrong current adjustment dial setting
3. Poor contacts of cables
4. Improper Cable Diameter
5. Insufficient connection to material
6. Dual Use
7. Engine output is down

Excessive Welding Arc

1. Output selector switch is to
『SINGLE』or 『RATED OUTPUT』
2. Wrong current adjustment dial position

28

1. Replenish oil
2. Replenish coolant/water
1. Turn to 『SINGLE』 or 『RATED
SPEED』
2. Turn the dial clockwise
3. Connect securely
4. Change cables according to
『 Selection – Welding Cable』
5. Connect securely
6. Stop using AC Power
7. Keep 50% duty cycle
1. Turn to 『ECO』 or 『DUAL』
2. Turn the dial counterclockwise

No AC output

1. Circuit breaker is to 『OFF』
1. Turn to 『ON』
2. Output selector switch is to『ECO』 2. Turn to 『SINGLE』 or 『DUAL』

AC Output is Weak

1. The power consumption of the load
exceeds the rated output
2. Dual Use

1. Adjust according to 『OUTPUT
LIMITATION』
2. Stop welding

Slow-Down does not activate

1. Short circuit of welding cable
2. The power consumption of the load
is 0.5A or below

1. Repair the short circuit
2. Turn the Slow-Down switch to
『OFF』

Engine does not stop

1. Stop Solenoid disorder

1.Turn the fuel lever to 『CLOSE』
to stop and repair

Black and white smoke exhaust
from muffler successively

1. Overloaded use

1. Keep the duty cycle
2. Adjust according to 『OUTPUT
LIMITATION』

29

DGW311DM

DGW311L

14. Engine Wiring Diagram

30

(220V

60Hz)

15. Generator Wiring Diagram

31

32

DGW311L - (W)220B
(220V

60Hz)

33

DGW311L - (W)380A

(380V

50Hz)

34

DGW311L - (W)400A
(400V

50Hz)

35

DGW311L - (W)415A
(415V

50Hz)

Head Office : 6−2−11,Ozuka−Nishi,
Asaminami−Ku,Hiroshima,
731−3167,Japan
Telephone : 81-82-849-2220

FAX : 81-82-849-2481

71902-94012



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Create Date                     : 2004:02:19 02:39:03Z
Modify Date                     : 2004:02:19 11:49:07+09:00
Page Count                      : 37
Creation Date                   : 2004:02:19 02:39:03Z
Mod Date                        : 2004:02:19 11:49:07+09:00
Producer                        : Acrobat Distiller 5.0.5 (Windows)
Metadata Date                   : 2004:02:19 11:49:07+09:00
Has XFA                         : No
EXIF Metadata provided by EXIF.tools

Navigation menu