Siemens Medical Solutions Department MED EH and S WRC Hand RC for medical x-ray-systems User Manual WirelessRemControl ADD

Siemens Medical Solutions, Department MED EH&S; Hand RC for medical x-ray-systems WirelessRemControl ADD

User Manual

AXIOM Aristos FX AXB4-310.621.01.01.02 - Draft - 1 / 8AddendumAXIOM Aristos FXWireless Remote Control  - Draft -Important informationThe functions of the Wireless Remote Control are activated via an RF transmitter. The Wireless Remote Control shall be operated in close vicinity to the patient table only and with full visibility to the patient on the table.The batteries shall always be sufficiently charged.The Wireless Remote Control can interfere with life supporting devices.Changes or modifications not expressly approved by the party responsible for compliance could void the user´s authority to operate the equipment.The Wireless Remote Control may be interfered with by other equipment, includ-ing portable and mobile RF communication equipment, even if such equipment meets the applicable emissions requirements.The Wireless Remote Control must emit electromagnetic energy in order to per-form its intended function. Nearby electronic equipment may be affected.hm_fdrad_sysmark_MovementInterruptbyStop_u06CautionMechanical or personal damageEmergency stop interrupts movements immediately◆Use remote control only when there is visual and accoustic contact with patient.◆In case of unintended movement press next emergency STOP button.
Wireless Remote Control  - Draft -2 / 8 AXB4-310.621.01.01.02 - Draft - AddendumOperationWireless Remote Control (example)The remote control is active in a range of appr. 5 m around the table/stand, where the receiver is mounted. If the remote control is in a wider range of the table, it may lose contact with the receiver and will then turn into an inactive mode.Display areaOperation areaSelection area
Wireless Remote Control  - Draft -AXIOM Aristos FX AXB4-310.621.01.01.02 - Draft - 3 / 8Display areaThere are 3 LEDs showing the status of the remote control.Green LED on: Remote control is on and is in active mode.Green LED off: Remote control is inactive.– It is too far away from the table – The Aristos FX is switched off – The batteries are completely discharged– The remote control is in “sleep mode”. Press a button swiftly to activate it again.Orange LED on: An operation button is being pressed.LED off: battery sufficiently charged, remote control not connected to the Charging Station, LED flashing red: battery needs charging, remaining capacity < 4h.LED on red: remote control connected to Charging Station and batteries are being charged.LED on green: remote control connected to Charging Station and batteries arefully charged.This symbol marks an RF transmitting component.Selection areaIn the selection area you can select which part of the system you want to operate.The green LED on the selected button is on.Selection of tube unitSelection of detectorSelection of patient tableSelection of collimator
Wireless Remote Control  - Draft -4 / 8 AXB4-310.621.01.01.02 - Draft - AddendumOperation areaAngular movement of tube unit and detectorAngular movement of tube unit and detector counter-clockwise about the α-axisAngular movement the tube unit and detector clockwise about the α-axisAngular movement the tube unit and detector counter-clockwise about the β-axisAngular movement the tube unit and detector clockwise about the β-axisDead-man switchOn the backside of the remote control there is a dead-man switch. To execute an operation with a button of the operation area you have to press the dead-man switch simultaneously.As soon as you release the dead-man switch, the current operation is stopped.
Wireless Remote Control  - Draft -AXIOM Aristos FX AXB4-310.621.01.01.02 - Draft - 5 / 8Opening/closing the collimator; moving tube unit and detector in x and y direction (orange and green)Closing the collimator in transverse directionMoving tube unit and detector in x direction (orange)Opening the collimator in transverse directionMoving tube unit and detector in x direction (orange)Closing the collimator in longitudinal directionMoving tube unit and detector in y direction (green)Opening the collimator in longitudinal directionMoving tube unit and detector in y direction (green)OGP position of patient table or parking positionMoving the patient table to OGP position;Moving the system in parking positionMoving detector, tube unit and patient tableMoving up and down detector, tube unit and patient table.
Wireless Remote Control  - Draft -6 / 8 AXB4-310.621.01.01.02 - Draft - Addendum’Center lock’ trackingDisable/enable ’center lock’ tracking– Press the ’center lock’ tracking button just for a short time (< 3 s) to acti-vate or deactivate center-lock tracking at the current position.When an OGP with centered tracking is selected press the tracking button longer than 3 s and keep it pressed (dead man switch). Detector and tube unit are then centered as programmed.– LED at tube support control panel lights up when tracking is active– LED at tube support control panel flashes when tracking is not possible or being in progressSID trackingDisable/enable SID tracking control– Press: The tracking control is switched off(on).– LED at tube support control panel lights up when tracking is active– LED at tube support control panel flashes when tracking is not possible or being in progressParking positionSwitching over the function of the OGP button to parking positionMarking signsThe Wireless Remote Control is marked with a colored sign of different shape to avoid a mix up for installations with a multitude of Wireless Remote Control. The same marks are attached to the respective table and room during installation.These are two examples of colored signs of different shape to mark the remote control to an Aristos FX system.
Wireless Remote Control  - Draft -AXIOM Aristos FX AXB4-310.621.01.01.02 - Draft - 7 / 8Charging StationThe Wireless Remote Control is plugged in the Charging Station for charging the batteries. It is recommended to charge the batteries every day after deployment.Charging StationIf the Wireless Remote Control needs charging during a patient procedure, sim-ply plug it in the Charging Station.Never use another charging device than the Charging Station delivered with the Wireless Remote Control. Usage of another charging station may cause severe damage to the Wireless Remote Control or may lead to hazards for the patients when the Wireless Remote Control is recharged during operation.Exchange of batteriesThe batteries of the Wireless Remote Control must be exchanged once a year by authorized and trained staff. Please call Siemens Service. Unauthorized exchange may cause severe damage.
Wireless Remote Control  - Draft -8 / 8 AXB4-310.621.01.01.02 - Draft - AddendumTechnical DataActive range Approximately 5 m around the receiver mounted to the stand.Charging time Approx. 2 hOperating time with full batteriesApprox. 12 hFrequency range 2402 MHz - 2480 MHzModulation GFSKRF Power 0 dBmRF emissions CISPR 11 Compliance: Group 2The deployment of Wireless Remote Control in combination with Aristos FX changes the classification of Artis from compliance group 1 to compliance group 2.