Siemens Medical Solutions Department MED EH and S WRCII Wireless Remote Control II User Manual Ysio full

Siemens Medical Solutions, Department MED EH&S; Wireless Remote Control II Ysio full

Contents

User Manual Footswitch

Download: Siemens Medical Solutions Department MED EH and S WRCII Wireless Remote Control II User Manual Ysio full
Mirror Download [FCC.gov]Siemens Medical Solutions Department MED EH and S WRCII Wireless Remote Control II User Manual Ysio full
Document ID1140435
Application IDGCsuo0TUhkudr+kM9p7n4A==
Document DescriptionUser Manual Footswitch
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize47.01kB (587665 bits)
Date Submitted2009-07-17 00:00:00
Date Available2009-07-17 00:00:00
Creation Date2008-09-11 12:15:05
Producing SoftwareAcrobat Distiller 6.0.1 (Windows)
Document Lastmod2009-07-09 16:26:11
Document TitleYsio_full_.book
Document CreatorFrameMaker 7.0

Safety
System Overview
System Components
System Operation
Accessories and Auxiliary Devices
Technical Data
Ysio
with fully automatic overhead support
Operator Manual
www.siemens.com/medical
Usability
BEFORE USING THIS SYSTEM
This system should be used only by employees adequately trained in the use of this equipment.
Before using this system, the operator should be thoroughly acquainted with the instructions for use and safety
recommendations provided in this manual.
Failure to follow the instructions for use and safety recommendations provided in this manual can cause serious
injury to the patient, to the operator or to other persons.
Important Information from the Manufacturer
This product is provided with a CE marking in accordance with the regulations stated in Appendix II of
the Directive 93/42/EEC of June 14th, 1993 concerning medical devices. In accordance with Appendix
IX of the Directive 93/42/EEC, this device is assigned to class II b.
The CE marking applies only to medical devices which have been put on the market according to the
above-mentioned EC Directive.
Unauthorized changes to this product invalidate this declaration.
Siemens AG
Wittelsbacherplatz 2
D-80333 Muenchen
Germany
© Siemens AG
All rights reserved
Order No.: AXB7-020.620.01.03.02
09.2008
Original Language: English
Contact Information
Siemens AG, Medical Solutions
Angiography, Fluoroscopic and Radiographic Systems
Siemensstrasse 1
D-91301 Forchheim
Germany
Telephone: +49 9191 18-0
www.siemens.com/medical
Accessories and Auxiliary Devices
Storing the BABIX cradle
— Remove the child from the BABIX cradle and attend to its needs.
— Hang the BABIX cradle on the wooden hook with the opening in the BABIX
cradle facing the retainer.
— Press the 2 longitudinal sides of the BABIX cradle into the grooves of the
retainer.
— Check to make sure that the BABIX cradle is securely seated in the retainer.
Wireless Remote Control
Important information
The functions of the Wireless Remote Control are activated via an RF transmitter.
Note
The Wireless Remote Control may be interfered by other equipment, including
portable and fixed RF communication equipment, even if such equipment meets
the applicable emission requirements.
The operator must assure that other wireless devices in the 2.4-GHz ISM band are
not operated in the vicinity of appr. 5 m around the Ysio wi-D system. System
movements can interrupt sporadically.
Please observe and verify normal operation of the Wireless Remote Control prior
to using it.
— Operate the Wireless Remote Control only in close vicinity to the patient table
and with full visibility to the patient on the table.
— Take care that the batteries are always sufficiently charged.
Caution
Wireless Remote control or portable detector generate an electromagnetic field
too high that disturbs life supporting device.
Interference with life supporting device resulting in possible malfunction
— Make sure to keep a safety separation distance of larger than 90 cm between
the Wireless Remote Control or portable detector or docking station and the life
supporting device.
— In case of interference with other equipment increase the distance between
the interfering devices.
154 / 168
AXB7-020.620.01.03.02
Operator Manual
Accessories and Auxiliary Devices
Caution
Collision with operator or patient
Mechanical or personal damage
— Take care that the used remote control and the system have the same colored
label.
— Use the remote control only when there is visual and acoustic contact with the
patient.
— If unintended movement occurs, press the next emergency STOP button.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user´s authority to operate the equipment.
The Wireless Remote Control may be interfered with by other equipment, including portable and mobile RF communication equipment, even if this equipment
meets the applicable emissions requirements.
In order to perform its intended function, the Wireless Remote Control must emit
electromagnetic energy. Maybe, nearby electronic equipment is affected.
Note
Use the remote control only inside the examination room.
Operation
The remote control is active in a range of appr. 5 m around the table/stand, where
the receiver is mounted. If the remote control is in a wider range of the table, it
may lose contact with the receiver. It then turns into an inactive mode.
Display area
Operation area
Selection area
Wireless Remote Control (example)
Ysio
AXB7-020.620.01.03.02
155 / 168
Accessories and Auxiliary Devices
Display area
There are 3 LEDs showing the status of the remote control.
‰ Green LED on: Remote control is on and is in active mode.
‰ Green LED off: Remote control is inactive.
– It is too far away from the table
– The Ysio wi-D is switched off
– The batteries are discharged
– The remote control is in “sleep mode”. Press a button swiftly to activate it
again.
Orange LED on: An operation button is being pressed.
‰ LED off: battery sufficiently charged, remote control not connected to the
Charging Station
‰ LED flashing red: battery needs charging, remaining capacity < 4 h
‰ LED on red: remote control connected to Charging Station and batteries are being charged
‰ LED on green: remote control connected to Charging Station and batteries are
fully charged
This symbol marks an RF transmitting component.
Selection area
In the selection area, you can select which part of the system you want to operate.
The green LED on the selected button is on.
Selection of tube unit
Selection of detector
Selection of patient table
Selection of collimator
156 / 168
AXB7-020.620.01.03.02
Operator Manual
Accessories and Auxiliary Devices
Operation area
Dead-man Note
switch
On the backside of the remote control, there is a dead-man switch. To execute an
operation with a button of the operation area you have to press the dead-man
switch simultaneously.
As soon as you release the dead-man switch, the current operation is stopped.
Note
All following operation directions only apply if you are standing in front of the
tube unit.
Angular movement of tube unit and detector
Angular movement of tube unit and detector clockwise about the α-axis
Angular movement of tube unit and detector counter-clockwise about the α-axis
Angular movement of tube unit and detector clockwise about the β-axis
Angular movement of tube unit and detector counter-clockwise about the β-axis
Opening/closing the collimator; moving tube unit and detector in x and y direction (orange and green)
Opening the collimator in transverse direction
Moving tube unit and detector in x direction (orange)
Closing the collimator in transverse direction
Moving tube unit and detector in x direction (orange)
Ysio
AXB7-020.620.01.03.02
157 / 168
Accessories and Auxiliary Devices
Opening the collimator in longitudinal direction
Moving tube unit and detector in y direction (green)
Closing the collimator in longitudinal direction
Moving tube unit and detector in y direction (green)
OGP position of patient table or parking position
Moving the patient table to OGP position;
Moving the system in parking position
Moving detector, tube unit, and patient table
Moving up and down detector, tube unit, and patient table.
’Center lock’ tracking
Disable/enable ’center lock’ tracking
– Press the ’center lock’ tracking button just for a short time (< 3 s) to activate
or deactivate center-lock tracking at the current position.
When an OGP with centered tracking is selected press the tracking button
longer than 3 s and keep it pressed (dead-man switch). Detector and tube
unit are then centered as programmed.
– LED at tube support control panel lights up when tracking is active
– LED at tube support control panel flashes when tracking is not possible or
being in progress
SID tracking
Disable/enable SID tracking control
– Press: The tracking control is switched off(on).
– LED at tube support control panel lights up when tracking is active
– LED at tube support control panel flashes when tracking is not possible or
being in progress
Parking position
Switching over the function of the OGP button to parking position
– Green LED is on.
After the parking position is reached, immediately switch off this function again.
– Green LED is off.
158 / 168
AXB7-020.620.01.03.02
Operator Manual
Accessories and Auxiliary Devices
Marking signs
The Wireless Remote Control is marked with a colored sign of different shape. So
you can avoid a mix up for installations with a multitude of Wireless Remote Controls. The same marks are attached to the respective table and room during installation.
These signs are 2 examples of colored signs of different shape to mark the remote
control to a Ysio wi-D system.
Charging Station
The Wireless Remote Control is plugged in the Charging Station for charging the
batteries. We recommend charging the batteries every day after deployment.
Charging Station
If the Wireless Remote Control needs charging during a patient procedure, simply
plug it in the Charging Station.
Never use another charging device than the Charging Station delivered with the
Wireless Remote Control.
Note
For safety reasons, never touch the charging contacts and the patient simultaneously when the charging station is connected to a socket (charging contacts are
permanently energized).
Installation
You can install the Charging Station either at the wall or on the table.
Exchange of batteries
Let authorized and trained staff exchange the batteries of the Wireless Remote
Control once a year. Please call Siemens Service. Unauthorized exchange may
cause severe damage.
Ysio
AXB7-020.620.01.03.02
159 / 168
Accessories and Auxiliary Devices
Technical Data
Active range
Approximately 5 m around the receiver mounted to the stand.
Charging time
Approx. 2 h
Operating time with
full batteries
Approx. 12 h
Frequency range
2402 MHz - 2480 MHz
Modulation
GFSK
RF Power
0 dBm
RF emissions CISPR 11
Compliance: Group 2
The deployment of Wireless Remote Control in combination with Ysio wi-D changes the classification of Ysio wi-D from compliance group 1 to compliance
group 2.
Footswitch
‰ Left foot switch for table down movement.
‰ Middle foot switch for table up movement.
‰ Right foot switch to release the brakes for table top floating.
Caution
Operator or patient does not recognize the cable of the foot switch or the foot
switch itself.
Injuries by stumbling
— Take special care to the location of the foot switch and the associated cable on
the floor.
160 / 168
AXB7-020.620.01.03.02
Operator Manual

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Mode                       : UseOutlines
XMP Toolkit                     : 3.1-702
About                           : uuid:18504375-1c34-46c9-9cf7-c1249530c47e
Producer                        : Acrobat Distiller 6.0.1 (Windows)
Creator Tool                    : FrameMaker 7.0
Modify Date                     : 2009:07:09 16:26:11+02:00
Create Date                     : 2008:09:11 12:15:05Z
Metadata Date                   : 2009:07:09 16:26:11+02:00
Document ID                     : uuid:b1e6f32d-d1c6-4412-9bb5-72004db00887
Instance ID                     : uuid:7f502653-ce39-411b-94aa-90bb840de331
Format                          : application/pdf
Title                           : Ysio_full_.book
Has XFA                         : No
Page Count                      : 9
Creator                         : FrameMaker 7.0
EXIF Metadata provided by EXIF.tools
FCC ID Filing: S5H-WRCII

Navigation menu