Siemens ELN1V1 Industrial WLAN Access Point User Manual SCALANCE W760 W720
Siemens AG Industrial WLAN Access Point SCALANCE W760 W720
Siemens >
Contents
- 1. User Manual
- 2. Operating Instructions
- 3. Reference Manual
Operating Instructions
SCALANCE W760/W720 ___________________ Information on the Internet ___________________ Introduction SIMATIC NET Industrial Wireless LAN SCALANCE W760/W720 Operating Instructions ___________________ Description ___________________ Mounting ___________________ Connection ___________________ Technical data ___________________ Dimension drawings ___________________ Approvals 03/2015 C79000-G8976-C322-05 Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION indicates that minor personal injury can result if proper precautions are not taken. NOTICE indicates that property damage can result if proper precautions are not taken. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. Trademarks All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Division Process Industries and Drives Postfach 48 48 90026 NÜRNBERG GERMANY C79000-G8976-C322-05 Ⓟ 05/2016 Subject to change Copyright © Siemens AG 2014 - 2015. All rights reserved Contents Information on the Internet ...................................................................................................................... 5 Introduction ............................................................................................................................................. 7 2.1 Information on the Operating Instructions ................................................................................ 7 2.2 Structure of the type designation .............................................................................................. 8 2.3 Security information .................................................................................................................. 8 Description .............................................................................................................................................. 9 3.1 Components of the product ...................................................................................................... 9 3.2 LED display ............................................................................................................................... 9 3.3 Reset button ............................................................................................................................11 Mounting ............................................................................................................................................... 13 4.1 Installing on a DIN rail / removing ...........................................................................................14 Connection ........................................................................................................................................... 15 5.1 Lightning protection, power supply and grounding .................................................................15 5.2 Power supply ..........................................................................................................................19 5.3 Ethernet ..................................................................................................................................20 5.4 Suitable cables for power supply and Ethernet ......................................................................20 5.5 Antenna connector ..................................................................................................................21 5.6 Suitable antenna cables and antennas...................................................................................22 Technical data ...................................................................................................................................... 25 6.1 Technical specifications W761/W722/W721 RJ-45 ................................................................25 Dimension drawings .............................................................................................................................. 27 Approvals.............................................................................................................................................. 29 Index..................................................................................................................................................... 31 SCALANCE W760/W720 Operating Instructions, 03/2015, C79000-G8976-C322-05 Information on the Internet Bitte beachten Sie die Warnhinweise und zusätzlichen Informationen in der Kompaktbetriebsanleitung in Ihrer Sprache im Internet: http://support.automation.siemens.com/ww/view/at/10806097 http://support.automation.siemens.com/ww/view/ch/10806097 http://support.automation.siemens.com/ww/view/de/10806097 http://support.automation.siemens.com/ww/view/li/10806097 http://support.automation.siemens.com/ww/view/lu/10806097 Please observe the warnings and additional information in the compact operating instructions in your language in the Internet: http://support.automation.siemens.com/ww/view/au/10806097 http://support.automation.siemens.com/ww/view/ca/10806097 http://support.automation.siemens.com/ww/view/gb/10806097 http://support.automation.siemens.com/ww/view/ie/10806097 http://support.automation.siemens.com/ww/view/us/10806097 http://support.automation.siemens.com/ww/view/za/10806097 Veuillez tenir compte des avertissements et informations supplémentaires de la notice de service dans votre langue sur Internet: http://support.automation.siemens.com/ww/view/be/10806097 http://support.automation.siemens.com/ww/view/ch/10806097 http://support.automation.siemens.com/ww/view/fr/10806097 http://support.automation.siemens.com/ww/view/lu/10806097 Si prega di tenere conto delle avvertenze e ulteriori informazioni nell’istruzione operativa compatta nella relativa lingua in Internet: http://support.automation.siemens.com/ww/view/it/10806097 Se ruega tener en cuenta las advertencias y las informaciones complementarias contenidas en las instrucciones de servicio (resumen) en español en Internet: http://support.automation.siemens.com/ww/view/cl/10806097 http://support.automation.siemens.com/ww/view/es/10806097 Dbejte prosím na výstražné pokyny a doplňkové informace v kompaktním návodu k obsluze ve vašem jazyce na internetu: http://support.automation.siemens.com/ww/view/cz/10806097 Vær venligst opmærksom på de advarselsanvisninger og ekstra informationer der findes på dit sprog i kompaktdriftsvejledningen på internettet: http://support.automation.siemens.com/ww/view/dk/10806097 Noudata lyhyen käyttöoppaan sisältämiä varoituksia ja huomio sen muutkin tiedot. Oman kielisesi käyttöoppaan löydät internetistä osoitteesta: http://support.automation.siemens.com/ww/view/fi/10806097 Λάβετε υπόψη τις υποδείξεις προειδοποίησης και τις πρόσθετες πληροφορίες των συνοπτικών οδηγιών χρήσης που παρέχονται στη γλώσσα σας στο Διαδίκτυο: http://support.automation.siemens.com/ww/view/gr/10806097 请注意互联网上精编版操作说明相应语言版本中的警告提示和附加信息: http://support.automation.siemens.com/ww/view/cn/10806097 SCALANCE W760/W720 Operating Instructions, 03/2015, C79000-G8976-C322-05 Information on the Internet http://support.automation.siemens.com/ww/view/hk/10806097 http://support.automation.siemens.com/ww/view/sg/10806097 Kérjük, vegye figyelembe az interneten található, az Ön anyanyelvén íródott kompakt használati útmutatóban található figyelmeztetéseket és további információkat: http://support.automation.siemens.com/ww/view/hu/10806097 Skoðið vel viðvaranir og aðrar upplýsingar í notkunarleiðbeiningunum á ykkar tungumáli á internetinu: http://support.automation.siemens.com/ww/view/is/10806097 インターネットサイトにある各言語の注意事項および追加情報を参照してください: http://support.automation.siemens.com/ww/view/jp/10806097 사이트에 있는 귀하의 언어로 된 콤팩트 사용 설명서에 명시된 경고 지침 및 추가 정보를 준수하십시오: http://support.automation.siemens.com/ww/view/kr/10806097 http://support.automation.siemens.com/ww/view/kw/10806097 Neem goed nota van de waarschuwingen en extra informatie in de compacte gebruiksaanwijzing in uw taal op internet: http://support.automation.siemens.com/ww/view/be/10806097 http://support.automation.siemens.com/ww/view/nl/10806097 Vennligst følg advarslene og annen informasjon i den kompakte bruksanvisningen, som du finner på ditt språk på internett: http://support.automation.siemens.com/ww/view/no/10806097 Proszę zwrócić uwagę na ostrzeżenia oraz dodatkowe informacje w kompaktowej instrukcji obsługi, dostępnej w odpowiednim języku w internecie: http://support.automation.siemens.com/ww/view/po/10806097 Observera varningshänvisningarna och extrainformationerna i kompaktbruksanvisningen som finns på ditt språk på internet: http://support.automation.siemens.com/ww/view/se/10806097 İnternette kendi dilinizdeki kompakt işletim kılavuzunda yer alan uyarı notlarına ve ek bilgilere lütfen dikkat edin: http://support.automation.siemens.com/ww/view/tr/10806097 SCALANCE W760/W720 Operating Instructions, 03/2015, C79000-G8976-C322-05 2 Introduction 2.1 Information on the Operating Instructions Validity of the Operating Instructions These operating instructions cover the following products: Article no. of the RoW version Article no. of the US version 6GK5761-1FC00-0AA0 6GK5761-1FC00-0AB0 SCALANCE W722-1 RJ-45 (iFeatures) 6GK5722-1FC00-0AA0 6GK5722-1FC00-0AB0 SCALANCE W721-1 RJ-45 6GK5721-1FC00-0AA0 6GK5721-1FC00-0AB0 Access point SCALANCE W761-1 RJ-45 Ethernet client modules These operating instructions apply to the following software version: ● SCALANCE W760/W720 with firmware as of Version 5.2 Purpose of the Operating Instructions Using the Operating Instructions, you will be able to install and connect the SCALANCE W760/W720 correctly. The configuration and the integration of the device in a WLAN are not described in these instructions. Documentation on the accompanying CD You will find detailed information about configuration in the SCALANCE W700 configuration manuals on the accompanying SIMATIC NET IWLAN CD under the file name: PH_SCALANCE-W760-W720-WBM_76.pdf and PH_SCALANCE-W760-W720-CLI_76.pdf Note Make sure that you read the explanations and instructions in the README.txt file License conditions Note Open source software Read the license conditions for open source software carefully before using the product. You will find license conditions in the following documents on the supplied data medium: ● DOC_License_74.pdf ● DOC_LicenseScalanceW_76.htm SCALANCE W760/W720 Operating Instructions, 03/2015, C79000-G8976-C322-05 Introduction 2.2 Structure of the type designation 2.2 Structure of the type designation The type designation of the device is made up of several parts that have the following meaning: 2.3 Security information Siemens provides automation and drive products with industrial security functions that support the secure operation of plants or machines. They are an important component in a holistic industrial security concept. With this in mind, our products undergo continuous development. We therefore recommend that you keep yourself informed with respect to our product updates. Please find further information and newsletters on this subject at: http://support.automation.siemens.com. To ensure the secure operation of a plant or machine it is also necessary to take suitable preventive action (e.g. cell protection concept) and to integrate the automation and drive components into a state-of-the-art holistic industrial security concept for the entire plant or machine. Any third-party products that may be in use must also be taken into account. Please find further information at: http://www.siemens.com/industrialsecurity SCALANCE W760/W720 Operating Instructions, 03/2015, C79000-G8976-C322-05 Description 3.1 Components of the product Description 3.1 Components of the product The following components are supplied with the product: ● SCALANCE W761 or SCALANCE W722 or SCALANCE W721 ● 1 protective cap for the antenna socket ● 1 connector for the power supply ● SIMATIC NET Industrial Wireless LAN CD Please check that the consignment you have received is complete. If the consignment is incomplete, contact your supplier or your local Siemens office. 3.2 LED display Information on operating status and data transfer On the front of the housing, several LEDs provide information on the operating status of the device: SCALANCE W760/W720 Operating Instructions, 03/2015, C79000-G8976-C322-05 Description 3.2 LED display LED Color Meaning L1 Green Power supply L1. Green There is a connection via the Ethernet interface (Link). Green and yellow flashing alternately Data transfer via the Ethernet interface. P1 R1 Green SCALANCE W760 in access point mode: The WLAN interface is initialized and ready for operation. SCALANCE W760 in client mode or SCALANCE W720: There is a connection via the WLAN interface. Green and yellow flashing alternately Green flashing briefly Data transfer over the WLAN interface. SCALANCE W760 in access point mode: With 802.11h, the channel is scanned for one minute for primary users before the channel can be used for data traffic. SCALANCE W760 in client mode or SCALANCE W720: The client waits for the MAC address due to the setting "Automatic" for the "MAC mode" parameter and is connected to no access point. P1 R1 Green flashing 3 x short, 1 x long SCALANCE W760 in client mode or SCALANCE W720: Red An error occurred during operation with the device. Red R1 flashing yellow at the same time A primary user was detected on all enabled channels. (only when DFS is enabled or according to IEEE 802.11h) Flashing yellow "Flashing" enabled using SIMATIC NET Primary Setup Tool (PST). The client waits for the MAC address due to the setting "Automatic" for the "MAC mode" parameter and is connected to an access point. Note Primary user (radar) on all enabled channels (only when DFS is enabled) If the device detects a primary user (for example radar signals) on all enabled channels of the WLAN interface, the LED F is lit and R1 flashes. No data traffic is then possible for the next 30 minutes. After this time, the device runs the scan again and checks whether a primary user still exists. If no primary user is detected, data traffic is possible again. The wait time of 30 minutes is necessary due to legal requirements and cannot be shortened even by restarting the device. SCALANCE W760/W720 10 Operating Instructions, 03/2015, C79000-G8976-C322-05 Description 3.3 Reset button 3.3 Reset button The reset button (position ①) is on the front of the housing: Functions of the reset button The reset button has the following functions: ● Restart of the device Note If you make changes to the configuration and restart immediately afterwards with the reset button, the changes may be lost. If you restart the device using the WBM (menu command "System > Restart") or using the CLI (command "restart" in the Privileged EXEC Modus), the configuration changes are always retained. ● Loading new firmware ● Restoring the default parameters (factory defaults) You will find more detailed information in the configuration manual SCALANCE W760/W720 WBM. SCALANCE W760/W720 Operating Instructions, 03/2015, C79000-G8976-C322-05 11 4 Mounting CAUTION Minimum distance to antennas Fit the device so that there is a minimum clearance of 20 cm between antennas and persons. WARNING If a device is operated in an ambient temperature of more than 50 °C, the temperature of the device housing may be higher than 70 °C. The device must therefore be installed so that it is only accessible to service personnel or users that are aware of the reason for restricted access and the required safety measures at an ambient temperature higher than 50 °C. WARNING When used in hazardous environments corresponding to Class I, Division 2 or Class I, Zone 2, the device must be installed in a cabinet or a suitable enclosure. General notes on use according to ATEX and IECEx WARNING To comply with EC Directive 94/9 (ATEX95) or the conditions of IECEx, this enclosure or cabinet must meet the requirements of at least IP54 in compliance with EN 60529. SCALANCE W760/W720 Operating Instructions, 03/2015, C79000-G8976-C322-05 13 Mounting 4.1 Installing on a DIN rail / removing 4.1 Installing on a DIN rail / removing Procedure for installation Follow the steps below to fit the SCALANCE W760/W720 to a DIN rail: 1. Place the device on the upper edge of the DIN rail as shown in the figure. 2. Press the device against the DIN rail until the DIN rail slider catch locks in place. Procedure when removing Follow the steps below to remove the SCALANCE W760/W720 from a DIN rail: 1. Press the release button on the top of the device to release the DIN rail catch. 2. Tilt the SCALANCE W760/W720 forward and remove the device from the DIN rail. SCALANCE W760/W720 14 Operating Instructions, 03/2015, C79000-G8976-C322-05 5 Connection 5.1 Lightning protection, power supply and grounding Lightning protection WARNING Danger due to lightning strikes Antennas installed outdoors must be within the area covered by a lightning protection system. Make sure that all conducting systems entering from outdoors can be protected by a lightning protection potential equalization system. When implementing your lightning protection concept, make sure you adhere to the VDE 0182 or IEC 62305 standard. Suitable lightning protectors are available in the range of accessories of SIMATIC NET Industrial WLAN: ● Lightning protector LP798-1N (order no. 6GK5798-2LP00-2AA6) ● Lightning protector LP798-2N (order no. 6GK5798-2LP10-2AA6) SCALANCE W760/W720 Operating Instructions, 03/2015, C79000-G8976-C322-05 15 Connection 5.1 Lightning protection, power supply and grounding Note We recommend that you use the maintenance-free lightning protector LP798-2N. Exception: When there is also DC power supplied via the antenna cable. In this case, only the lightning protector LP798-1N can be used. WARNING Danger due to lightning strikes Installing this lightning protector between an antenna and a SCALANCE W700 is not adequate protection against a lightning strike. The LP798-1N lightening protector only works within the framework of a comprehensive lightning protection concept. If you have questions, ask a qualified specialist company. Note The requirements of EN61000-4-5, surge immunity tests on power supply lines, are met only when a Blitzductor is used with 24 VDC: BVT AVD 24 type no. 918 422 Manufacturer: DEHN+SÖHNE GmbH+Co.KG, Hans Dehn Str. 1, Postfach 1640, D 92306 Neumarkt, Germany Supply voltage WARNING Safety extra low voltage The equipment is designed for operation with Safety Extra-Low Voltage (SELV) by a Limited Power Source (LPS). This means that only SELV / LPS (Limited Power Source) complying with IEC 60950-1 / EN 60950-1 / VDE 0805-1 must be connected to the power supply terminals or the power supply unit for the equipment power supply must comply with NEC Class 2, as described by the National Electrical Code (r) (ANSI / NFPA 70). If the equipment is connected to a redundant power supply (two separate power supplies), both must meet these requirements. WARNING Transient overvoltages Take measures to prevent transient voltage surges of more than 40% of the rated voltage. This is the case if you only operate devices with SELV (safety extra-low voltage). SCALANCE W760/W720 16 Operating Instructions, 03/2015, C79000-G8976-C322-05 Connection 5.1 Lightning protection, power supply and grounding Grounding WARNING Danger to life from overvoltage, fire hazard When using outdoor antennas, the shared or even grounded pin of the circuit must be connected to the shield of the coaxial cable and with all touchable conductive parts and circuits. Otherwise, in the event of a fault there may be illegally high voltages on touchable parts. NOTICE Damage to the device due to potential differences To fully eliminate the influence of electromagnetic interference, the device must be grounded. There must be no potential difference between the following parts, otherwise the device or other connected device could be severely damaged: • Grounding pin of the SCALANCE W700 and the ground potential of the antenna. • Grounding pin of the SCALANCE W700 and the ground potential of a device connected over Ethernet. • Grounding pin of the SCALANCE W700 and the shield contact of the connected Ethernet cable. Connect both grounds to the same foundation earth or use an equipotential bonding cable. WARNING EXPLOSION HAZARD SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2 OR ZONE 2. WARNING EXPLOSION HAZARD DO NOT OPEN WHEN ENERGIZED. General notes on use according to ATEX and IECEx WARNING EXPLOSION HAZARD DO NOT CONNECT OR DISCONNECT EQUIPMENT WHEN A FLAMMABLE OR COMBUSTIBLE ATMOSPHERE IS PRESENT. SCALANCE W760/W720 Operating Instructions, 03/2015, C79000-G8976-C322-05 17 Connection 5.1 Lightning protection, power supply and grounding General notes on use in hazardous areas according to UL-HazLoc WARNING EXPLOSION HAZARD DO NOT DISCONNECT WHILE CIRCUIT IS LIVE UNLESS AREA IS KNOWN TO BE NON-HAZARDOUS. This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D or nonhazardous locations only. This equipment is suitable for use in Class I, Zone 2, Group IIC or non-hazardous locations only. SCALANCE W760/W720 18 Operating Instructions, 03/2015, C79000-G8976-C322-05 Connection 5.2 Power supply 5.2 Power supply The power is supplied to the SCALANCE W760/W720 via the three-pin socket. Socket The three-pin socket has the following pin assignment: Pin Assignment L+ +24 VDC Ground Grounding SCALANCE W760/W720 Operating Instructions, 03/2015, C79000-G8976-C322-05 19 Connection 5.3 Ethernet 5.3 Ethernet The SCALANCE W760/W720 has two Ethernet interfaces located on the underside of the device (position ①). 5.4 Suitable cables for power supply and Ethernet Cable specification The following table lists the requirements for a cable depending on the application. Application Specification Direct 24 VDC supply • Round cable cross-section with 6 to 8 mm diameter. Two-wire cable with 0.5 to 1.5 mm2 cross-section per wire. • Permitted tensile load at least 100 N. • UL listing: Type PLTC or ITC Ethernet 1. IE FC TP standard cable GP 2 x 2 (type A) Order no.: 6XV1 840-2AH10 2. IE TP torsion cable 2 x 2 (type C) Order no.: 6XV1 870-2F 3. IE FC TP trailing cable 2 x 2 (type C) Order no.: 6XV1 840 3AH10 UL listing: Type PLTC or ITC (the three named types have this approval) SCALANCE W760/W720 20 Operating Instructions, 03/2015, C79000-G8976-C322-05 Connection 5.5 Antenna connector 5.5 Antenna connector The SCALANCE W760/W720 has an antenna connector R1 A1 of the type R-SMA located on the front of the device (position ①). Procedure Follow the steps below to connect a cable for an external antenna to a SCALANCE W760/720: 1. Insert the connector on the antenna cable into the R-SMA socket R1 A1 (position ①) and tighten the retainer nut on the socket (key size SW8, tightening torque 0.6 Nm). Note Cabinet installation When installing the SCALANCE W760/720 in a cabinet, you need to use a detached antenna. Suitable connecting cables for a connection between SCALANCE W760/720 and a detached antenna are available from SIMATIC NET. You will find detailed information in the following section. SCALANCE W760/W720 Operating Instructions, 03/2015, C79000-G8976-C322-05 21 Connection 5.6 Suitable antenna cables and antennas 5.6 Suitable antenna cables and antennas N-Connect/R-SMA connecting cable To connect an antenna with an N-Connector, the following cables are suitable: Length Order number 0.3 m 6XV1875-5CE30 1m 6XV1875-5CH10 2m 6XV1875-5CH20 5m 6XV1875-5CH50 10 m 6XV1875-5CN10 Suitable antennas Note When you select an antenna, keep in mind the national approvals for your device. Type Properties Order number ANT792-6MN Omni antenna, mast/wall mounting, 6 dBi 2.4 GHz, N-Connect female 6GK5 792-6MN00-0AA6 ANT793-6MN Omni antenna, mast/wall mounting, 5 dBi 5 GHz, N-Connect female 6GK5 793-6MN00-0AA6 ANT793-8DJ Directional antenna, mast/wall mounting, 18 dBi 5 GHz, 2 x N-Connect female 6GK5 793-8DJ00-0AA0 ANT793-8DK Directional antenna, mast/wall mounting, 23 dBi 5 GHz, 2 x N-Connect female 6GK5 793-8DK00-0AA0 ANT793-8DP Directional antenna, mast/wall mounting, 13 / 13.5 dBi 4.9 GHz and 5 GHz, N-Connect female 6GK5793-8DP00-0AA0 ANT795-6DC Wide angle antenna, mast/ wall mounting, 9 dBi 2.4 GHz and 5 GHz, N-Connect female 6GK5 795-6DC00-0AA0 ANT793-6DG Wide angle antenna, mast/ wall mounting, 9 dBi 5 GHz, 2 x N-Connect female 6GK5 793-6DG00-0AA0 ANT795-6MN Omni antenna, mounted on roof/vehicle, 6/8 dBi 2.4 GHz and 5 GHz, N-Connect female 6GK5 795-6MN10-0AA6 ANT795-4MC Omnidirectional antenna, 3/5 dBi, 2.4 GHz and 5 GHz, IP65, N-Connect male for direct installation on the device, straight connector. 6GK5 795-4MC00-0AA3 SCALANCE W760/W720 22 Operating Instructions, 03/2015, C79000-G8976-C322-05 Connection 5.6 Suitable antenna cables and antennas ANT795-4MD Omnidirectional antenna, 3/5 dBi, 2.4 GHz and 5 GHz, IP65, N-Connect male for direct installation on the device, 90° connector. 6GK5 795-4MD00-0AA3 ANT795-4MA Omni antenna, directly on the device, 3/5 dBi 2.4 GHz and 5 GHz, IP30, R-SMA connector male for direct mounting on the device, connector angle adjustable 0° to 180°. 6GK5 795-4MA00-0AA3 ANT792-4DN RCoax helical antenna, circular polarization, 4 dBi, 2.4 GHz, N-connect female. 6GK5 792-4DN00-0AA6 ANT793-4MN RCoax λ5/8 antenna with vertical polarization, 6 dBi, 5 GHz, N-connect female. 6GK5 793-4MN00-0AA6 ANT795-4MX Omni Antenna, 2/2,5 dBi, 2,4 GHz and 6GK5795-4MX00-0AA0 5GHz, IP69K, N-Connect male ANT795-6MP Omni Antenna 5/7 dBi, 2,4 GHz and 5GHz, 6GK5795-6MP00-0AA0 IP67, N-Connect female ANT896-6MM Omni Antenna for Mobile Wireless, WLAN 6GK5896-6MM00-0AA0 and GPS, WLAN: 6/7 dBi, 2,4 GHz and 5GHz, IP68, IP69 K, QMA-Connect female, Port 2 ANT793-8DL Directional Antenna, 5 GHz, 14dBi, IP66, 6GK5793-8DL00-0AA0 2xN-Connect female IWLAN RCoax cable 2.4 Omni antenna, 0 dBi GHz PE 1/2" 2.400 - 2.485 GHz, N-Connect female. 6XV1875-2A IWLAN RCoax cable 5 GHz PE 1/2" 6XV1875-2D Omni antenna, 0 dBi 5.150 - 5.875 GHz, N-Connect female. NOTICE ANT795-4MA The ANT795-4MA antenna has degree of protection IP30 and is therefore suitable for dry environments. Note ANT793-8DJ The antenna ANT793-8DJ may only be used with the antenna cable 6XV1875-5CH50 (5 m length) or 6XV1875-5CN10 (10 m length). Other antenna cables are not permitted. Notice for USA/Canada Only one antenna per device can be used (connected to R1A1, R1A2 or R2A1, R2A2). SCALANCE W760/W720 Operating Instructions, 03/2015, C79000-G8976-C322-05 23 Connection 5.6 Suitable antenna cables and antennas Note ANT793-8DK The antenna ANT793-8DK may only be used with the antenna cable 6XV1875-5CN10 (10 m length). Other antenna cables are not permitted. Notice for USA/Canada Only one antenna per device can be used (connected to R1A1, R1A2 or R2A1, R2A2). SCALANCE W760/W720 24 Operating Instructions, 03/2015, C79000-G8976-C322-05 6 Technical data 6.1 Technical specifications W761/W722/W721 RJ-45 The following technical specifications apply to the following devices: ● SCALANCE W761-1 RJ-45 ● SCALANCE W722-1 RJ-45 ● SCALANCE W721-1 RJ-45 Note You will find detailed information on the transmit power and receiver sensitivity in the document "Performance data 802.11 abgn SCALANCE W760/W720" on the supplied data medium (REF_W760-RadioInterface.pdf). SCALANCE W761/W722/W721 Data transfer Ethernet transfer rate 10 / 100 Mbps Wireless transmission rate 1 ... 150 Mbps Wireless standards supported IEEE 802.11a IEEE 802.11b IEEE 802.11g IEEE 802.11n Attachment to Industrial Ethernet Quantity Design RJ-45 jack Properties Half duplex/full duplex, autocrossover, autonegotiation, autosensing, floating Permitted cable lengths (Ethernet) (Alternative combinations per length range) 0 ... 55 m • Max. 55 m IE TP Torsion Cable with IE FC RJ45 Plug 180 • Max. 45 m IE TP Torsion Cable with IE FC RJ45 + 10 m TP Cord via IE FC RJ45 Outlet • Max. 85 m IE FC TP Marine/Trailing/Flexible/FRNC/Festoon/Food Cable with IE FC RJ45 Plug 180 • Max. 75 m IE FC TP Marine/Trailing/Flexible/FRNC/Festoon/Food Cable + 10 m TP Cord via IE FC RJ45 Outlet • Max. 100 m IE FC TP Standard Cable with IE FC RJ45 Plug 180 • Max. 90 m IE FC TP Standard Cable + 10 m TP Cord via IE FC RJ45 Outlet 0 ... 85 m 0 ... 100 m SCALANCE W760/W720 Operating Instructions, 03/2015, C79000-G8976-C322-05 25 Technical data 6.1 Technical specifications W761/W722/W721 RJ-45 SCALANCE W761/W722/W721 Wireless interface Antenna connector Quantity Design R-SMA female Impedance 50 Ω nominal Frequency range 2412 ... 2480 MHz 4920 ... 5875 MHz Electrical data Power supply Supply voltage 24 VDC Safe Extra Low Voltage (SELV) Permitted range 19.2 to 28.8 VDC Design Terminal block, 3 terminals Fusing 2.5 A / 24 VDC Current consumption Typical 150 mA Power loss at 24 VDC Typical 3.6 W During operation with the rack installed horizontally 0 ℃ to +55 ℃ During operation with the rack installed vertically 0 ℃ to +55 ℃ During storage -40 ℃ to +85 ℃ During transportation -40 ℃ to +85 ℃ Relative humidity During operation ≤ 95% at 25 °C, no condensation Operating altitude During operation ≤ 2,000 m above sea level at max. 55 °C ambient temperature Contaminant concentration According to IEC 60721 Permitted ambient conditions Ambient temperature Design, dimensions and weight Degree of protection IP20 Weight 130 g Dimensions (W x H x D) 50 x 114 x 74 mm Installation options Installation on a DIN rail Mean time between failure (MTBF) at 40 °C ambient temperature 106.51 years SCALANCE W760/W720 26 Operating Instructions, 03/2015, C79000-G8976-C322-05 Dimension drawings SCALANCE W760/W720 Operating Instructions, 03/2015, C79000-G8976-C322-05 27 8 Approvals You will find the approvals of the products in the reference work "Approvals SCALANCE W700 802.11n" on the Internet pages of Siemens Industry Online Support: ● Using the search function: support.automation.siemens.com (http://support.automation.siemens.com/WW/view/en) Enter the entry ID of the relevant manual as the search item. ● In the navigation panel on the left-hand side in the area "Industrial Communication": Industrial communication (http://support.automation.siemens.com/WW/view/en/10805878/133300) Go to the required product group and make the following settings: "Entry list" tab, Entry type "Manuals / Operating Instructions" You will find the documentation for the SIMATIC NET products relevant here on the data storage medium that ships with some products: ● Product CD / product DVD ● SIMATIC NET Manual Collection ● SIMATIC NET IWLAN CD SCALANCE W760/W720 Operating Instructions, 03/2015, C79000-G8976-C322-05 29 Index Antenna Connector, 21 Antennas Specification, 22 Article numbers, 7 Reset button, 11 Resetting the device, 11 Restart of the device, 11 Safety extra low voltage, 16 Scope of delivery, 9 Supply voltage, 16 Cables Specification, 20, 22 Connectors, 9 Dimension drawing, 27 Documentation on the CD, 7 Technical specifications, 25 Type designation, 8 Ethernet interface, 20 Grounding, 15 Installation DIN rail, 14 Interfaces, 25 LED display, 9 Lightning protection, 15 Loading firmware, 11 Primary user (radar), 9 Protective cap, 9 SCALANCE W760/W720 Operating Instructions, 03/2015, C79000-G8976-C322-05 31 Index SCALANCE W760/W720 32 Operating Instructions, 03/2015, C79000-G8976-C322-05
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : Siemens AG Create Date : 2016:05:13 06:35:02+02:00 Keywords : "C79000-G8976-C322-05;, 03/2015" Modify Date : 2016:05:13 09:19:20+02:00 XMP Toolkit : XMP Core 5.1.2 Metadata Date : 2016:05:13 06:36:15+02:00 Creator Tool : Acrobat PDFMaker 11 für Word Document ID : uuid:7b347621-a62c-4466-b514-0b7399e3ef48 Instance ID : uuid:9ffadb89-51b1-4d93-aba2-fe0bf970517d Format : application/pdf Title : SCALANCE W760/W720 Description : SIMATIC NET Creator : Siemens AG Subject : C79000-G8976-C322-05; 03/2015 Producer : Adobe PDF Library 11.0 Source Modified : D:20160513043414 Company : Siemens AG Edition : 0.00148883374689826 System : SIMATIC NET Print-year : 2014 - 2015 Document-class : Operating Instructions Document-class-mrl : Product-group : Industrial Wireless LAN Order-nr : C79000-G8976-C322-05 Ident-nr : Company-short : Siemens Company-long : Siemens AG Headline : Operating Instructions Page Layout : OneColumn Page Mode : UseOutlines Page Count : 32EXIF Metadata provided by EXIF.tools