Siemens MOBYI-SLG41CN Inductive TAG System User Manual MOBY I en A71
Siemens AG Inductive TAG System MOBY I en A71
Siemens >
Users Manual
Table of Contents MOBY I Configuration, Installation and Service Manual 6GT2 097-4BA00-0EA2 Published in January, 2002 General Introduction to MOBY I Configuration and Mounting Guidelines Mobile Data Memories Read/Write Devices Interfaces Accessories Documentation Error Messages ASCII Table Compatibility Safety Guidelines This manual contains notices which you should observe to ensure your own personal safety, as well as to protect the product and connected equipment. These notices are highlighted in the manual by a warning triangle and are marked as follows according to the level of danger. Danger indicates that death, severe personal injury or substantial property damage will result if proper precautions are not taken. Warning indicates that death, severe personal injury or substantial property damage can result if proper precautions are not taken. Caution indicates that minor personal injury or property damage can result if proper precautions are not taken. Note draws your attention to particularly important information on the product, handling the product, or to a particular part of the documentation. Qualified Personnel Only qualified personnel should be allowed to install and work on this equipment. For the purposes of the safety notes contained in this manual; qualified persons are defined as persons who are authorized to commission, to ground, and to tag circuits, equipment, and systems in accordance with established safety practices and standards. Correct Usage Note the following. Warning This device and its components may only be used for the applications described in the catalog or the technical description, and only in connection with devices or components from other manufacturers which have been approved or recommended by Siemens. This product can only function correctly and safely if it is transported, stored, set up, and installed correctly, and operated and maintained as recommended. Trademarks MOBY, SIMATIC and SINEC are registered trademarks of SIEMENS AG. Some of the other designations used in this documentation are also registered trademarks; the owner’s rights may be violated if they are used by third parties for their own purposes. Copyright Siemens AG 1997 All rights reserved Disclaimer of Liability The reproduction, transmission or use of this document or its contents is not permitted without express written authority. Offenders will be liable for damages. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. We have checked the contents of this manual for agreement with the hardware and software described. Since deviations cannot be precluded entirely, we cannot guarantee full agreement. However, the data in this manual are reviewed regularly and any necessary corrections included in subsequent editions. Suggestions for improvement are welcomed. Siemens AG Automation and Drives Systems Engineering Postfach 23 55, D-90713 Fuerth Siemens Aktiengesellschaft Siemens AG 1997, 1998, 1999, 2000, 2001, 2002 Technical data subject to change Order No. 6GT2 097-4BA00-0EA2 Configuration and Mounting Guidelines MOBY I Configuration, Installation and Service Manual (4) J31069-D0033-U001-A7.1-7618 3-1 Configuration and Mounting Guidelines 3.1 Basic Requirements Warning Do not make changes to the devices. Violation will invalidate interference emission certification (BZT, FCC), CE and the manufacturer’s warranty. FCC Compliance Statement Note Any unauthorized modifications to this device could void the user’s authority to operate the equipment. To choose the correct MOBY I components, apply the following criteria to your particular application. Transmission distance (i.e., read/write distance) The amount of data to be transferred Metal-free spaces for MDS and SLG Static or dynamic transmission of the data Speed for dynamic transmission Tolerances of the tracking Environmental conditions (e.g., moisture, temperature, chemical influences and so on) 3-2 MOBY I Configuration, Installation and Service Manual (4) J31069-D0033-U001-A7.1-7618 Read/Write Devices 5.4 SLG 41/SLG 41-S Application area The SLG 41 is a low-end read/write device. It is particularly suitable for use when the MDS conveyor system (e.g., pallets) can be physically positioned relatively precisely. The swivel head of the SLG 41 makes it very adaptable to the transportation system. In dynamic operation, only a small amount of data can be read or written between SLG 41 and MDS. In contrast to the SLG 41, the antenna of the SLG 41-S is rotated by 90° in the swivel head so that all positions of the transmission window can be implemented. Figure 5-12 Ordering data Technical data SLG 41 Table 5-8 Ordering data for SLG 41/SLG 41-S Read/write device up to 25 mm SLG 41 SLG 41-S (antenna turned 90°) 6GT2 001-0AA00 6GT2 001-0AA00-ZA23 SLG plug connector and stub lines See chapter 3.10 Table 5-9 Technical data of SLG 41/SLG 41-S Inductive interface to MDS Data transmission speed 19200 baud Read/write distance SLG to MDS (max.) 30 mm (see field data table) Transmission frequency Power Data 134 kHz Serial interface to ASM 6-pin SLG plug connector in acc. w. DIN 43651 Transmission speed 19200 baud, RS 422 Line length, ASM to SLG (max.) at 24 V DC 360 m 1.81 MHz Supply voltage (via serial interface) 5-12 Nominal value 24 V DC Permissible range 20 to 30 V DC MOBY I Configuration, Installation and Service Manual (4) J31069-D0033-U001-A7.1-7618 Read/Write Devices Table 5-9 Technical data of SLG 41/SLG 41-S Current consumption Idle/operation 20 mA / 90 mA MTBF 2 x 106 Housing Dimensions in mm (W x H x D) 120 x 40 x 40 Color Anthracite/ergo-gray Material Polyamide 12 Plug connection DIN 43651 Protection rating IP65 Shock 50 g Vibration 20 g Mounting of SLG 4 M5 screws Turning moment (at room temperature) 3 Nm Ambient temperature Field data During operation –25° to +70° C During transportation and storage –40° to +85° C Weight (approx.) 210 g The exact field data are dependent on the type of MDS used. Table 5-10 Field data of SLG 41/SLG 41-S Operating distance (Sa) 0 to 15 mm Limit distance (Sg) 30 mm Median deviation (L) Depends on MDS Minimum distance from SLG to SLG (D) > 200 mm FCC information Made in Germany SIEMENS MOBY I SLG 41 THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES: OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. Note The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment: Such modifications could void the user’s authority to operate the equipment. MOBY I Configuration, Installation and Service Manual (4) J31069-D0033-U001-A7.1-7618 5-13 Read/Write Devices Transmission window Transmission window at operating distance SLG 41-S Transmission window at operating distance Figure 5-13 SIEMENS Length of transmission window (L) Metal-free space ÏÏÏ ÏÏÏ ÏÏÏ ÏÏÏ ÏÏÏÏÏÏ ÏÏÏ ÏÏÏ ÏÏÏ ÏÏÏ ÏÏÏ ÏÏÏ SIEMENS Length of transmission window (L) Transmission window of SLG 41/SLG 41-S ÏÏÏÏÏÏÏÏÏÏÏ ÏÏÏÏÏÏÏÏÏÏÏ ÏÏÏÏÏÏÏÏÏÏÏ ÏÏÏÏÏÏÏÏÏÏÏ ÏÏÏÏÏÏÏÏÏÏÏ ÏÏÏÏÏÏÏÏÏÏÏ ÏÏÏÏÏÏÏÏÏÏÏ ÏÏÏÏÏÏÏÏÏÏÏ ÏÏÏÏÏÏÏÏÏÏÏ ÏÏÏÏÏÏÏÏÏÏÏ ÏÏÏÏÏÏÏÏÏÏÏ ÏÏÏÏÏÏÏÏÏÏÏ SIEMENS SIEMENS SIEMENS SIEMENS Figure 5-14 a = 25 mm Metal-free space with flush installation a = 25 mm Metal-free space with flush installation Metal-free space for SLG 41/SLG 41-S Definition of distance D SLG 41 / SLG 41-S SLG 41 SLG 41 Figure 5-15 5-14 Distance D for SLG 41/SLG 41-S MOBY I Configuration, Installation and Service Manual (4) J31069-D0033-U001-A7.1-7618 Read/Write Devices Dimensions (in mm) SLG 41: 40 28 80 SIEMENS 40 40 49 25 Position of swivel head on delivery 30 60 .3 5,3 40 14.5 SLG 41-S: 40 28 40 40 80 SIEMENS Possible read head changes with the swivel head 49 60 40 Position of swivel head on delivery 30 5.3 Figure 5-16 25 14.5 Dimensional diagram of SLG 41/SLG 41-S SIEMENS SLG 41 SIEMENS SLG 41-S SIEMENS SIEMENS Figure 5-17 Read head changes of SLG 41/SLG 41-S MOBY I Configuration, Installation and Service Manual (4) J31069-D0033-U001-A7.1-7618 5-15 Read/Write Devices 5.5 SLG 41C/SLG 41CC Application area The SLG 41C is a low-end read/write device. It is small and compact and is excellent for use in small assembly lines. The high protection rating and use of high-quality materials ensure that the SLG 41C can easily handle even most rugged industrial conditions. It is connected with a 3-m cable which is equipped with core sleeves at the end. This connection line can be extended with terminals or a user-provided connection plug. This connection plug of the ASM is used for the connection to the ASM. The cable length of the SLG 41CC is 2 m. The end of the cable is equipped with a twin M-12 plug. This can be used to connect the SLG 41CC directly to an ASM 450/452/473. Figure 5-18 Ordering data Table 5-11 SLG 41C/41CC read/write device Ordering data of SLG 41C/41CC Read/write device SLG 41C 6GT2 001-0AC00 SLG 41CC read/write device with twin M-12 plug 6GT2 001-0AC00-0AX0 Accessories: Extension cable (not fabricated) Connection plug for ASM 450/473 Technical data Table 5-12 6GT2 090-0A... 6GT2 090-0BC00 Technical data of SLG 41C/41CC Inductive interface to MDS Read/write distance, SLG-MDS, max. 30 mm (see field data) Transmission frequency 5-16 Power 134 kHz Data 1.81MHz MOBY I Configuration, Installation and Service Manual (4) J31069-D0033-U001-A7.1-7618 Read/Write Devices Table 5-12 Technical data of SLG 41C/41CC Serial interface to evaluation unit RS 422 Data transmission rate 19 200 Baud Line length, ASM-SLG max. (for 24V DC) 360 m Serial interface to user SLG 41C 3 m connection line; open end SLG 41CC 2 m connection line; twin M-12 plug for ASM 450/452/473 Voltage Nominal value 24 V DC Permissible range 20 V to 30 V DC Current consumption at room temerature Standby 30 mA Operation 70 mA (typical) Housing Dimensions (L x W x H) in mm 55 x 75 x 30 Color Gray Material Plastic (polyamide 12) Connection 3 m connection line, cable ends with core sleeves and labels Protection rating an acc. w. EN 60 529 IP67 Shock 50 g Vibration 20 g Mounting of SLG 4 M 5 screws Tightening moment (at room temperature) < 2 Nm Ambient temperature During operation –25° C to +70° C During transpostation and storage –40° C to +85° C Weight approx. MOBY I Configuration, Installation and Service Manual (4) J31069-D0033-U001-A7.1-7618 210 g 5-17 Read/Write Devices Field data (in mm) Table 5-13 Field data of SLG 41C/41CC MDS 401/402 MDS 403 MDS 404/514 Working distance (Sa) 0 to 6 4 to 15 0 to 12 Limit distance (Sg) 10 30 25 L: Vertical 2L: Horizontal 20 65 30 40 – 60 Width of transmission window (W) 25 12 Transmission window Minimum distance from SLG to SLG 200 200 200 FCC information Made in Germany SIEMENS MOBY I SLG 41C THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES: OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. Note The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment: Such modifications could void the user’s authority to operate the equipment. 5-18 MOBY I Configuration, Installation and Service Manual (4) J31069-D0033-U001-A7.1-7618 Read/Write Devices Transmission window 12 Transmission window at working distance 12 20 Length of the transmission window (L) for MDS 401/402 30 Length of the transmission window for (L) MDS 404/514 L = 65 Length of the transmission window SIEMENS Transmission window at working distance B = 25 Width of the transmission window Lenght of the transmisison window for MDS 403 Figure 5-19 The transmission window is marked on the housing The MDS moves along the “SIEMENS” label on the housing. Transmission window of SLG 41C/41CC MOBY I Configuration, Installation and Service Manual (4) J31069-D0033-U001-A7.1-7618 5-19 Read/Write Devices Metal-free space SIEMENS MOBY I SLG 41C a = 15 mm Metal-free area with flush installation Figure 5-20 Metal-free area of SLG 41C/41CC Definition of distance D SIEMENS MOBY I SLG 41C Minimum distance from SLG to SLG D = ≥ 200 mm SIEMENS MOBY I SLG 41C Figure 5-21 5-20 SIEMENS MOBY I SLG 41C Distance D: SLG 41C/41CC MOBY I Configuration, Installation and Service Manual (4) J31069-D0033-U001-A7.1-7618 Read/Write Devices Dimensions (in mm) 30 55 75 ∅ 5.5 65 SIEMENS MOBY I SLG 41C 55 45 Core color Designation Brown – Receiving Pink + 24 V Gray Ground (0V) Green + Sending Yellow – Sending White + Receiving Black Cable shield 30 Core and sleeves Flexible cable anti-kink guard 0.1 m 3m 75 ∅ 5.5 65 SIEMENS MOBY I SLG 41CC 55 45 30 2m Figure 5-22 Dimensions of SLG 41C/41CC MOBY I Configuration, Installation and Service Manual (4) J31069-D0033-U001-A7.1-7618 5-21
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Encryption : Standard V1.2 (40-bit) User Access : Print, Fill forms, Extract, Assemble, Print high-res Create Date : 2002:01:28 14:53:59 Producer : Acrobat Distiller 3.01 for Windows Author : GHirschmann Creator : Interleaf, Inc. Title : MOBY_I_en_A71 Modify Date : 2002:04:10 12:22:44+02:00 Page Count : 14EXIF Metadata provided by EXIF.tools