Siemens MPCI1V1 Siemens Industrial Access Point/ EAP Family User Manual BAK SCALANCE W786 76

Siemens AG Siemens Industrial Access Point/ EAP Family BAK SCALANCE W786 76

users manual

   SIMATIC NET Betriebsanleitung (kompakt) Operating Instructions (Compact) Ausgabe/Release 03/2007  SCALANCE W786-1PRO SCALANCE W786-2PRO SCALANCE W786-3PRO  Deutsch/English    A5E01048819-01 A5E01048819-01 © SIEMENS AG 2007 Änderungen vorbehalten Subject to change
   ii  Betriebsanleitung (kompakt) SCALANCE W786  A5E01048819-01  Inhaltsverzeichnis / Table of Contents    Seite / Page  Deutsch.......................................................................................................................1 English ......................................................................................................................59
 Betriebsanleitung (kompakt) SCALANCE W786  iii A5E01048819-01-04-04 Bitte beachten Sie die Warnhinweise und zusätzlichen Informationen in der Be-triebsanleitung (kompakt) in Ihrer Sprache im Internet: http://www4.ad.siemens.de/view/cs/at/18690255 http://www4.ad.siemens.de/view/cs/ch/18690255 http://www4.ad.siemens.de/view/cs/de/18690255 http://www4.ad.siemens.de/view/cs/li/18690255 http://www4.ad.siemens.de/view/cs/lu/18690255 Please observe the warnings and additional information in the user manual (com-pact) in your language in the Internet: http://www4.ad.siemens.de/view/cs/au/18690255 http://www4.ad.siemens.de/view/cs/ca/18690255 http://www4.ad.siemens.de/view/cs/gb/18690255 http://www4.ad.siemens.de/view/cs/ie/18690255 http://www4.ad.siemens.de/view/cs/us/18690255 http://www4.ad.siemens.de/view/cs/za/18690255 Veuillez observer les avertissements et informations supplémentaires du manuel d’utilisation (compact) dans votre langue dans l’internet: http://www4.ad.siemens.de/view/cs/be/18690255 http://www4.ad.siemens.de/view/cs/ch/18690255 http://www4.ad.siemens.de/view/cs/fr/18690255 http://www4.ad.siemens.de/view/cs/lu/18690255 Osservare le avvertenze di sicurezza e le informazioni aggiuntive nel manuale d'istruzioni (compatto) nella propria lingua in Internet: http://www4.ad.siemens.de/view/cs/it/18690255 Por favor, observe las indicaciones de advertencia y las informaciones adicionales en las instrucciones de servicio (compactas) en su idioma disponibles en Internet: http://www4.ad.siemens.de/view/cs/cl/18690255 http://www4.ad.siemens.de/view/cs/es/18690255 Berte prosím v úvahu výstražné pokyny a dodatečné informace v provozním návodu (kompakt) na internetu ve vaší řeči: http://www4.ad.siemens.de/view/cs/cz/18690255 De bedes iagttage advarselsanvisningerne og de yderligere informationer i betjeningsvejledningen (kompakt) for Deres sprog på internettet: http://www4.ad.siemens.de/view/cs/dk/18690255
   iv  Betriebsanleitung (kompakt) SCALANCE W786  A5E01048819-01  Huomioi internetissä oman kielisessäsi käyttöohjeessa (kompakti) olevat varoitusohjeet ja lisäinformaatiot: http://www4.ad.siemens.de/view/cs/fi/18690255 Προσέξτε παρακαλώ τις προειδοποιητικές υποδείξεις και τις πρόσθετες πληροφορίες στις οδηγίες λειτουργίας (συνεπτηγµένες) στη γλώσσα σας στο διαδίκτυο. http://www4.ad.siemens.de/view/cs/gr/18690255 请遵守互联网上用您的语言编写的用户手册(简易版)中的警告信息和附加说明: http://www4.ad.siemens.de/view/cs/cn/18690255 http://www4.ad.siemens.de/view/cs/hk/18690255 http://www4.ad.siemens.de/view/cs/sg/18690255 Kérjük, vegye figyelembe az Interneten található magyar nyelvű használati utasításban (kompakt) olvasható figyelmeztető utasításokat és a kiegészítő információkat! http://www4.ad.siemens.de/view/cs/hu/18690255 Vinsamlegast athugið varúðarábendingar og viðbótarupplýsingar í notendahandbók-inni (stytt útgáfa) á Netinu: http://www4.ad.siemens.de/view/cs/is/18690255 以下のインターネットアドレスでお客様の言語による取扱説明書(コンパクト版)をご覧  http://www4.ad.siemens.de/view/cs/jp/18690255 いただけます。同取扱説明書内に記載された警告事項および補足情報にご注意ください。 인터넷 http://www4.ad.siemens.de/view/cs/kr/18690255에서 귀하의 사용 언어로 된 사용자 설명서(컴팩트)의 경고 및 추가 정보를 확인하십시오.  لﻴﻟﺩﺒ ﺔﻘﺤﻠﻤﻟﺍ ﺔﻴﻓﺎﻀﻹﺍ ﺕﺎﻤﻭﻠﻌﻤﻟﺍﻭ ﺭﻴﺫﺤﺘﻟﺍ ﺕﺍﺩﺎﺸﺭﺇ ﺓﺎﻋﺍﺭﻤ ﺀﺎﺠﺭﺒ لﻴﻐﺸﺘﻟﺍ)ﺞﻤﺩﻤﻟﺍ (ﻟﺎﺒﻭﺕﻨﺭﺘﻨﻹﺍ ﺔﻜﺒﺸ ﻕﻴﺭﻁ ﻥﻋ ﻙﻟﺫﻭ ﺎﻬﺒ ﺙﺩﺤﺘﺘ ﻲﺘﻟﺍ ﺔﻐﻠ:  http://www4.ad.siemens.de/view/cs/kw/18690255
 Betriebsanleitung (kompakt) SCALANCE W786  v A5E01048819-01-04-04  Neem de waarschuwingen en de bijkomende informatie in acht, te vinden in de handleiding (compact) in uw taal in het internet: http://www4.ad.siemens.de/view/cs/be/18690255 http://www4.ad.siemens.de/view/cs/nl/18690255 Vennligst se advarsler og ytterligere opplysninger i driftsveiledningen (kompakt) på ditt språk i Internett: http://www4.ad.siemens.de/view/cs/no/18690255 Por favor observe as advertências e as informações adicionais no manual de instruções (compacto) na sua língua na internet: http://www4.ad.siemens.de/view/cs/po/18690255 Var vänlig observera varningarna och tilläggsinformationerna i bruksanvisningen (kompakt) på ditt språk på Internet: http://www4.ad.siemens.de/view/cs/se/18690255 Lütfen internette sizin dilinizde sunulan işletme kılavuzundaki (yoğunlaştırılmış) uyarı bilgilerine ve ek bilgilere dikkat ediniz: http://www4.ad.siemens.de/view/cs/tr/18690255
   vi  Betriebsanleitung (kompakt) SCALANCE W786  A5E01048819-01
  Safety Guidelines This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. Danger  indicates that death or severe personal injury will result if proper precautions are not taken. Warning  indicates that death or severe personal injury may result if proper precautions are not taken. Caution  with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken. Caution  without a safety alert symbol, indicates that property damage can result if proper precautions are not taken. Notice  indicates that an unintended result or situation can occur if the corresponding information is not taken into account. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The device/system may only be set up and used in conjunction with this documentation. Commissioning and operation of a device/system may only be performed by qualified personnel. Within the context of the safety notes in this documentation qualified persons are defined as persons who are authorized to commission, ground and label devices, systems and circuits in accordance with established safety practices and standards. Prescribed Usage Note the following: Warning  This device may only be used for the applications described in the catalog or the technical description and only in connection with devices or components from other manufacturers which have been approved or recommended by Siemens. Correct, reliable operation of the product requires proper transport, storage, positioning and assembly as well as careful operation and maintenance. Trademarks All names identified by ® are registered trademarks of the Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions.    Siemens AG Automation and Drives Postfach 48 48 90437 NÜRNBERG GERMANY   Ⓟ 03/2007 Copyright © Siemens AG  . Technical data subject to change
 Operating Instructions (compact) SCALANCE W-786 Operating Instructions,  ,    5  Table of contents   1  Introduction ............................................................................................................................................... 7 1.1  Information on the Operating Instructions (compact) SCALANCE W786 ..................................... 7 2  Description................................................................................................................................................ 9 2.1  Scope of delivery ........................................................................................................................... 9 2.2  Product properties ....................................................................................................................... 10 2.3  LED display.................................................................................................................................. 13 2.4  C-PLUG ....................................................................................................................................... 16 2.5  Reset button................................................................................................................................. 17 2.6  Biological compatibility................................................................................................................. 18 3  Assembling ............................................................................................................................................. 19 3.1  Removing / fitting the housing cover ........................................................................................... 19 3.2  Connecting up cables .................................................................................................................. 21 3.3  Mounting without an adapter (wall mounting only)...................................................................... 24 3.4  Mounting with mounting plate...................................................................................................... 26 3.4.1  Fitting the mounting plate to a wall.............................................................................................. 26 3.4.2  Fitting the mounting plate to an S7 standard rail......................................................................... 28 3.4.3  Fitting the mounting plate to a DIN rail ........................................................................................ 29 3.4.4  Fitting the mounting plate to a mast ............................................................................................ 30 3.4.5  Fitting the SCALANCE W786 to a mounting plate ...................................................................... 31 4  Connecting.............................................................................................................................................. 33 4.1  Lightning protection, power supply, and grounding..................................................................... 33 4.2  Suitable cables for the SCALANCE W786 .................................................................................. 35 4.3  Connecting the cables ................................................................................................................. 36 4.4  Connectors for the power supply of the SCALANCE W786........................................................ 40 4.5  Connecting a power supply adapter............................................................................................ 42 4.6  Connection for Industrial Ethernet............................................................................................... 45 4.7  Connectors for external antennas ............................................................................................... 46 4.8  Inserting / removing the C-PLUG ................................................................................................ 47 5  Technical data......................................................................................................................................... 49 5.1  SCALANCE W786 technical specifications................................................................................. 49 5.2  Permitted antennas...................................................................................................................... 51 6  Certification............................................................................................................................................. 53 6.1  Approvals for SCALANCE W786................................................................................................. 53
Table of contents      Operating Instructions (compact) SCALANCE W-786 6 Operating Instructions,  ,   6.2  SCALANCE W786 national approvals......................................................................................... 57   Index....................................................................................................................................................... 61
 Operating Instructions (compact) SCALANCE W-786 Operating Instructions,  ,    7  Introduction  1 1.1  Information on the Operating Instructions (compact) SCALANCE W786 Validity of the Operating Instructions (compact) These Operating Instructions (compact) cover the following products: ●  SCALANCE W786-1PRO ●  SCALANCE W786-2PRO ●  SCALANCE W786-3PRO These Operating Instructions (compact) apply to the following software version: ●  SCALANCE W786 firmware as of Version 3.2 Purpose of the Operating Instructions (compact) Based on the Operating Instructions (compact), you will be able to install and connect up the SCALANCE W786 correctly. Configuring the SCALANCE W786 and integrating the SCALANCE W786 in a WLAN are not dealt with in this manual. Documentation on the accompanying CD You will find detailed information on configuration in the Operating Instructions SCALANCE W786 on the accompanying CD in the file  BA_SCALANCE-W786_76.pdf
Introduction   1.1 Information on the Operating Instructions (compact) SCALANCE W786  Operating Instructions (compact) SCALANCE W-786 8 Operating Instructions,  ,
 Operating Instructions (compact) SCALANCE W-786 Operating Instructions,  ,    9  Description  2 2.1  Scope of delivery The following components are supplied with the SCALANCE W786: ●  SCALANCE W786 ●  5 caps for the cover screws ●  Depending on the version, up to 8 plugs for sealing the housing. ●  Depending on the version, up to 8 strain relief clamps ●  1 connector for the 48 V DC power supply ●  2 sealing sleeves for FO cables (not for devices with RJ-45 port) ●  1 SIMATIC NET Industrial Wireless LAN CD with these Operating Instructions for the SCALANCE W78x ●  1 Operating Instructions (compact) SCALANCE W786 Please check that the consignment you have received is complete. If it is not complete, please contact your supplier or your local Siemens office.
Description   2.2 Product properties  Operating Instructions (compact) SCALANCE W-786 10 Operating Instructions,  ,   2.2  Product properties Possible applications of the SCALANCE W786 The SCALANCE W786 is equipped with an Ethernet port and up to three wireless LAN ports. This makes the device suitable for the following applications: ●  The SCALANCE W786 forwards data within its transmission range from one node to another without a connection to wired Ethernet being necessary. ●  The SCALANCE W786 can be used as a gateway from a wired to a wireless network. ●  The SCALANCE W786 can be used as a wireless bridge between two networks. ●  The SCALANCE W786 can be used as a bridge between two cells operating at different frequencies. With a SCALANCE W786 with more than one WLAN port, you can also implement a redundant wireless connection to a SCALANCE W78x with at least two WLAN ports. Properties of the SCALANCE W786 ●  The Ethernet interface supports 10 Mbps and 100 Mbps, both in full and half duplex as well as autocrossing and autopolarity. ●  Operating the wireless interface in the frequency bands 2.4 GHz and 5 GHz. ●  The wireless interface is compatible with the standards IEEE 802.11a, IEEE 802.11h, IEEE 802.11b and IEEE 802.11g. In the 802.11a, 802.11h and 802.11g mode, the gross transmission rate is up to 54 Mbps. In turbo mode, the transmission rate is up to 108 Mbps (not permitted in all countries and modes).  ●  As an expansion of the 802.11a mode, it is also possible to operated according to the IEEE 802.11h standard. In 802.11h mode, the procedures Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) are used in the range 5.25 - 5.35 and 5.47 - 5.75 GHz. In some countries, this allows the frequency subband of 5.47 - 5.725 GHz to be used outdoors even with a higher transmit power. TPC is a technique of controlling the transmit power by reducing it to the strength actually required. With dynamic frequency selection (DFS), the access point searches for primary users (for example radar) on a randomly selected channel before starting communication. If signals are found on the channel, this channel is disabled for 30 minutes and the availability check is repeated on another channel. ●  Support of the authentication standards WPA, WPA-PSK, WPA2, WPA2-PSK and IEEE 802.1x and the encryption methods WEP, AES and TKIP. ●  Suitable for inclusion of a RADIUS server for authentication. ●  Device-related and application-related monitoring of the wireless connection. ●  The interoperability of SCALANCE W786 devices with Wi-Fi devices of other vendors was tested thoroughly.    Note In client mode, you can use a SCALANCE W786-xPRO with the functionality of a SCALANCE W746-1PRO.
 Description  2.2 Product properties Operating Instructions (compact) SCALANCE W-786 Operating Instructions,  ,    11 The following table illustrates the differences between the various variants of the SCALANCE W786:  Type  Number of WLAN ports Number and type of Ethernet ports Number of internal antennas Number of R-SMA sockets for external antennas Order no. W786-1PRO  1  1 RJ-45  1 (diversity(2))  —  6GK5786-1BA60-2AA0 6GK5786-1BA60-2AB0 (1) W786-1PRO  1  1 RJ-45  —  2  6GK5786-1AA60-2AA0 6GK5786-1AA60-2AB0 (1) W786-1 PRO   1  1 ST duplex multimode FO cable 1 (diversity(2)) —  6GK5786-1BB60-2AA0 6GK5786-1BB60-2AB0 (1) W786-1 PRO   1  1 ST duplex multimode FO cable —  2  6GK5786-1AB60-2AA0 6GK5786-1AB60-2AB0 (1) W786-2PRO  2  1 RJ-45  2 (diversity(2)) —  6GK5786-2BA60-2AA0 6GK5786-2BA60-2AB0 (1) W786-2PRO  2  1 RJ-45  —  4  6GK5786-2AA60-2AA0 6GK5786-2AA60-2AB0 (1) W786-2 PRO   2  1 ST duplex multimode FO cable 2 (diversity(2)) —  6GK5786-2BB60-2AA0 6GK5786-2BB60-2AB0 (1) W786-2 PRO   2  1 ST duplex multimode FO cable —  4  6GK5786-2AB60-2AA0 6GK5786-2AB60-2AB0 (1)
Description   2.2 Product properties  Operating Instructions (compact) SCALANCE W-786 12 Operating Instructions,  ,   Type  Number of WLAN ports Number and type of Ethernet ports Number of internal antennas Number of R-SMA sockets for external antennas Order no. W786-3PRO  3  1 RJ-45  —  6  6GK5786-3AA60-2AA0 6GK5786-3AA60-2AB0 (1) W786-3 PRO   3  1 ST duplex multimode FO cable —  6  6GK5786-3AB60-2AA0 6GK5786-3AB60-2AB0 (1) (1) US variant (2) There are two internal antennas per WLAN port. The antenna used is always the one that provides the best possible data transmission (diversity). You will find more information on the configuration parameters of the particular device in the SCALANCE W786 online help of Web Based Management. Requirements for installation and operation A PG/PC with a network attachment must be available to configure the SCALANCE W786. If no DHCP server is available, a PC on which the Primary Setup Tool (PST) is installed is necessary for the initial assignment of an IP address to the SCALANCE W786. For the other configuration settings, a computer with Telnet or an Internet browser is necessary.
 Description  2.3 LED display Operating Instructions (compact) SCALANCE W-786 Operating Instructions,  ,    13 2.3  LED display Information on operating status and data transfer On the front of the housing, several LEDs provide information on the operating status of the SCALANCE W786: s/ 3 5 5 5 )3R(6&$/$1&(:/ 3 5 )3R(6&$/$1&(:[/ 3 5 5 )3R(6&$/$1&(:[/ 3 5 5 5 )3R(6&$/$1&(:[ Figure 2-1  The LED display of the SCALANCE W786   Note The "PoE" LED does not exist on devices with a port for FO cable.
Description   2.3 LED display  Operating Instructions (compact) SCALANCE W-786 14 Operating Instructions,  ,    LED  Color  Description L1  Green  Power supply over a power supply adapter or the 48 V DC energy contacts of devices with a port for FO cable. PoE  Green  Power over Ethernet or power over the 48 V DC energy contacts of devices with an RJ-45 port. Yellow  Data transfer over the Ethernet interface (traffic). Green  There is a connection over the Ethernet port. (Link). Flashing yellow  PRESET-PLUG detected. Yellow/green  PRESET function completed successfully. P1 Flashing green  "Flashing" enabled over PST. Yellow  Data transfer over the first WLAN interface. Green Access Point Mode: The WLAN interface is initialized and ready for operation. Client Mode: There is a connection over the first WLAN port. Flashing green Access Point Mode: The channels are being scanned. Client Mode: The client is searching for a connection to an access point or ad hoc network. Green flashing quickly Access Point Mode: With 802.11h, the channel is scanned for one minute for primary users before the channel can be used for data traffic. Client Mode: The client waits for the adopt MAC address due to the setting <Auto Find Adopt MAC> and is connected to no access point. Green 3x fast, 1x long flashing Client Mode: The client waits for the adopt MAC address due to the setting <Auto Find Adopt MAC> and is connected to an access point. Flashing yellow  PRESET-PLUG detected. R1 Yellow/green  PRESET function completed successfully. Yellow Access Point Mode: Data transfer over the second WLAN port. Client Mode: The LED is always off because the 2nd port is not available in client mode. Green Access Point Mode: The WLAN interface is initialized and ready for operation. Client Mode: The LED is always off because the 2nd port is not available in client mode. R2 Flashing green Access Point Mode: The channels are being scanned. Client Mode: The LED is always off because the 2nd port is not available in client mode.
 Description  2.3 LED display Operating Instructions (compact) SCALANCE W-786 Operating Instructions,  ,    15 LED  Color  Description Green flashing quickly Access Point Mode: With 802.11h, the channel is scanned for one minute for primary users before the channel can be used for data traffic. Client Mode: The LED is always off because the 2nd port is not available in client mode. Flashing yellow  PRESET-PLUG detected.  Yellow/green  PRESET function completed successfully. Yellow Access Point Mode: Data transfer over the third WLAN port. Client Mode: The LED is always off because the 3rd port is not available in client mode. Green Access Point Mode: The WLAN interface is initialized and ready for operation. Client Mode: The LED is always off because the 3rd port is not available in client mode. Flashing green Access Point Mode: The channels are being scanned. Client Mode: The LED is always off because the 3rd port is not available in client mode. Green flashing quickly Access Point Mode: With 802.11h, the channel is scanned for one minute for primary users before the channel can be used for data traffic. Client Mode: The LED is always off because the 3rd port is not available in client mode. Flashing yellow  PRESET-PLUG detected. R3 Yellow/green  PRESET function completed successfully. Red  An error occurred during operation with the SCALANCE W786. F Flashing red  Ready to load firmware. The device was either stopped with the reset button or there is incorrect firmware on the device.    Note If the LED for the WLAN port is not green when the device starts up, although it is activated, the port is not ready for operation (interface not initialized). The main reason for this is usually that during commissioning of the SCALANCE W78x products, a waiting time of up to 15 minutes can occur when the ambient temperature is below zero. The device is ready for operation at the specified ambient temperature as soon as the LED for the WLAN interface is lit green.
Description   2.4 C-PLUG  Operating Instructions (compact) SCALANCE W-786 16 Operating Instructions,  ,   2.4  C-PLUG Configuration information on the C-PLUG The C-PLUG is used to transfer the configuration of the old device to the new device when a device is replaced. When the new device starts up with the C-PLUG, it then continues automatically with exactly the same configuration as the old device. One exception to this can be the IP configuration if it is set over DHCP and the DHCP server has not been reconfigured accordingly. Reconfiguration is necessary if you use WDS or redundancy and use the MAC addresses and not the sysNames. These functions are then based on the MAC address that inevitably changes if a device is replaced.   Note As soon as the device is started with a C-PLUG inserted, the SCALANCE W-700 starts up with the configuration data on the C-PLUG.
 Description  2.5 Reset button Operating Instructions (compact) SCALANCE W-786 Operating Instructions,  ,    17 2.5  Reset button Functions of the reset button The reset button is located below the housing cover beside the sockets for external antennas.  Figure 2-2  Position of the reset button with the housing cover removed The reset button has the following functions: ●  Restart of the device To restart the device, press the reset button. ●  Loading new firmware If the normal procedure with the Load & Save menu of Web Based Management was completed successfully, the reset button can be used to load new firmware. This situation can occur if there was a power outage during the normal firmware update. ●  Restoring the default parameters (factory defaults) ●  Adopting the configuration data from the PRESET PLUG.
Description   2.6 Biological compatibility  Operating Instructions (compact) SCALANCE W-786 18 Operating Instructions,  ,   2.6  Biological compatibility Electromagnetic fields and health With regard to the question of whether electromagnetic fields (for example in association with industrial wireless LANs) can put human health at risk, we refer to a publication of BITKOM (German Association for information Technology, Telecommunication and New Media e. V.), dated December 2003: "The same health guidelines apply to WLAN devices as to all other radio applications. These regulations are based on the protection concept of ICNIRP1 or the corresponding recommendation of the European Council. The independent German radiation protection commission (SSK) was commissioned by the federal German ministry of the environment to investigate the possible dangers - thermal and non-thermal - resulting from electromagnetic fields and came to the following conclusions2: 'The German Commission on Radiological Protection concludes that according to the latest scientific literature no new scientific research is available with respect to proven health hazards which would throw doubt upon the scientific evaluation which serves as the basis for the ICNIRP safety concepts and the recommendations of the EU commission.' The SSK also concludes that below the current limit values, these is also no scientific suspicion of health risks. This assessment agrees with those of other national and international scientific commissions and of the WHO (www.who.int/emf). Accordingly and in view of the fact that WLAN devices are significantly below the scientifically established limit values, there are no health risks from the electromagnetic fields of WLAN products. 1 International Council on Non-Ionizing Radiation Protection 2 'Limit Values and Precautionary Measures to Protect the General Public from Electromagnetic Fields' Recommendation of the Radiation Protection Commission (SSK) with scientific justification, Issue 29, 2001." You will find further information on this topic under the following URL: www.bitkom.org
 Operating Instructions (compact) SCALANCE W-786 Operating Instructions,  ,    19  Assembling  3 3.1  Removing / fitting the housing cover When does the housing cover need to be removed? You can only perform the following activities when the cover is removed. ●  You want to screw the SCALANCE W786 to a wall or onto the optional mounting plate. ●  You want to connect cables to the SCALANCE W786 for the power supply, for Ethernet or for external antennas. ●  You want to insert a C-PLUG in the device or replace an existing C-PLUG. ●  You want to use the reset button.
Assembling   3.1 Removing / fitting the housing cover  Operating Instructions (compact) SCALANCE W-786 20 Operating Instructions,  ,   Removing the housing cover s6&$/$1&(:/35 55 )3R($&% Figure 3-1  Removing the cover A Sealing cap B Cover screw C Housing cover Follow the steps below to remove the housing cover: 1.  Remove the sealing caps from the housing cover (position A in the figure above) 2.  Loosen the screws in the cover (position B in the figure above).    Note These screws remain in the cover after they have been loosened (prevents them being lost). Never attempt to remove these screws from the housing cover using force, otherwise the housing cover will be damaged! 3.  Remove the housing cover with the captive screws (position C in the figure above). Fitting the housing cover Fitting the housing cover is carried out in the reverse order. Tightening torque for the cover screws 1.8 Nm.
 Assembling  3.2 Connecting up cables Operating Instructions (compact) SCALANCE W-786 Operating Instructions,  ,    21 3.2  Connecting up cables Connecting up cables prior to mounting Before you screw a SCALANCE W786 to a wall or to the optional mounting plate, the cables for the power supply, for Ethernet, and, when necessary, for the external antennas must be connected up first. The available options are as follows: $% & Figure 3-2  Side view of a SCALANCE W786 with cables entering from different directions ●  The cables are inserted from above (position A in the previous schematic). The housing of the SCALANCE W786 has an opening at the top for this purpose. ●  The cables are inserted from below (position B in the previous schematic). There is also an opening at the bottom for this purpose. ●  Cables inserted through a wall behind the SCALANCE W786 (position C in the previous schematic). In this case, you will need to mount the SCALANCE W786 so that the opening in the wall is located above the lower edge of the device.
Assembling   3.2 Connecting up cables  Operating Instructions (compact) SCALANCE W-786 22 Operating Instructions,  ,   Connecting up FO cables Fiber-optic cables have a minimum bending radius. The cable must not be bent tighter than this bending radius during installation or operation, otherwise the FO cable will be irreperably damaged. 55!PP$ Figure 3-3  Connecting up an FO cable For the FO cable, use the second opening from the left in the seal. Cable routing is illustrated in the figure above. For individual cores immediately following the connector, the minimum bending radius is 25 mm. Refer to the specification of the cable you are using for the minimum permitted bending radius of the cable within the jacket. Make sure that the FO cable is not sharply kinked after passing through the housing. A sealing sleeve must be used in the housing sealing with FO cables (position A in the figure above). For more detailed information, refer to the section "Connecting the cables".
 Assembling  3.2 Connecting up cables Operating Instructions (compact) SCALANCE W-786 Operating Instructions,  ,    23 Grounding terminal  Warning  To operate the SCALANCE W786 safely, the chassis ground connector must have a suitable cable connected. Do not use the SCALANCE W786 without a ground cable connected.  The chassis ground connector is located on the rear of the device (M4 thread). Connect the ground cable before you mount the SCALANCE W786 on a wall or on the optional mounting plate. Once the SCALANCE W786 is mounted, the connector is no longer accessible. Place the supplied toothed washer directly on the rear of the device before screwing on the ground cable. Only then can you be sure that there is ideal contact with the screwed-on cable.   Figure 3-4  Chassis ground connector on the rear of the SCALANCE W786
Assembling   3.3 Mounting without an adapter (wall mounting only)  Operating Instructions (compact) SCALANCE W-786 24 Operating Instructions,  ,   3.3  Mounting without an adapter (wall mounting only) Drilling template The location of the holes for mounting the SCALANCE W786 on a wall is shown in the following figure:      Figure 3-5  Drilling template for wall mounting of the SCALANCE W786
 Assembling   3.3 Mounting without an adapter (wall mounting only) Operating Instructions (compact) SCALANCE W-786 Operating Instructions,  ,    25 Procedure $% Figure 3-6  SCALANCE W786 wall mounting Follow the steps below to screw a SCALANCE W786 to a wall: 1.  Lead the cables into the housing of the SCALANCE W786 (position A in the figure above). Note the information in the section "Connecting up cables". 2.  Secure the SCALANCE W786 to the wall with three screws (position B in the figure above). The screws are not supplied with the device. The type and length of the screws depend on the type of wall. Option: Threaded holes on rear of housing When a wall is extremely thin, it is often not possible to use wall plugs for the screws. To allow wall mounting even in this situation, there are four M4 threaded holes on the rear of the SCALANCE W786. The drilling template is a square with sides 100 mm long. The device can therefore be mounted on a wall with bolts through the wall.
Assembling   3.4 Mounting with mounting plate  Operating Instructions (compact) SCALANCE W-786 26 Operating Instructions,  ,   3.4  Mounting with mounting plate 3.4.1  Fitting the mounting plate to a wall Drilling template The location of the holes for fitting the mounting plate to a wall is shown in the following figure:     Figure 3-7  Drilling template for fitting the mounting plate to a wall
 Assembling  3.4 Mounting with mounting plate Operating Instructions (compact) SCALANCE W-786 Operating Instructions,  ,    27 Procedure Secure the mounting plate to the wall with four screws. The screws are not supplied with the device. The type and length of the screws depend on the type of wall.  Figure 3-8  Fitting the mounting plate for the SCALANCE W786 to a wall
Assembling   3.4 Mounting with mounting plate  Operating Instructions (compact) SCALANCE W-786 28 Operating Instructions,  ,   3.4.2  Fitting the mounting plate to an S7 standard rail Procedure %$ Figure 3-9  Side view of a mounting plate on an S7 standard rail Follow the steps below to fit the mounting plate to an S7 standard rail: 1.  Place the mounting plate with the two protruding catches on the top edge of the S7 standard rail (position A in the figure above). 2.  At the bottom, the mounting plate has two lugs with holes. Screw the lugs to the S7 standard rail (position B in the figure above). The required screws are supplied with the mounting plate.
 Assembling  3.4 Mounting with mounting plate Operating Instructions (compact) SCALANCE W-786 Operating Instructions,  ,    29 3.4.3  Fitting the mounting plate to a DIN rail Procedure $$% Figure 3-10  Mounting plate with fittings for DIN rail mounting Follow the steps below to fit the mounting plate to a DIN rail: 1.  Place the mounting plate with the two catches (position A in the figure above) on the upper edge of the DIN rail. 2.  Pull down the DIN rail sliding catch (position B in the figure above) and press the mounting plate against the DIN rail until the sliding catch engages.
Assembling   3.4 Mounting with mounting plate  Operating Instructions (compact) SCALANCE W-786 30 Operating Instructions,  ,   3.4.4  Fitting the mounting plate to a mast Procedure %$ Figure 3-11  Mounting plate with fittings for mast mounting Follow the steps below to fit the mounting plate to a mast: 1.  Feed the fastening straps through the openings in the mounting plate (position A in the figure above). 2.  Place the fastening straps around the mast at the required position. 3.  Feed the free end of the strap through the quick-release fastener. You can twist the tensioning screw (position B in the figure above) to the side to adapt a fastening strap to the diameter of the mast. 4.  Press the tensioning screw against the fastening strap and tighten the tensioning screw, tightening torque 4.5 Nm.
 Assembling  3.4 Mounting with mounting plate Operating Instructions (compact) SCALANCE W-786 Operating Instructions,  ,    31 3.4.5  Fitting the SCALANCE W786 to a mounting plate Procedure &$% Figure 3-12  Fitting the SCALANCE W786 to a mounting plate Follow the steps below to fit a SCALANCE W786 to a mounting plate: 1.  Lead the cables into the housing of the SCALANCE W786 (position A in the figure above). Note the information in the section "Connecting up cables". 2.  Fit the SCALANCE W786 so that the upper edge of the rear of the housing is below the two catches of the mounting plate (position B in the figure above). 3.  Push in the SCALANCE W786 until it engages in the notches at the lower edge of the mounting plate (position C in the figure above).
Assembling   3.4 Mounting with mounting plate  Operating Instructions (compact) SCALANCE W-786 32 Operating Instructions,  ,   & Figure 3-13  Screwing a SCALANCE W786 to a mounting plate 4.  Screw the SCALANCE W786 using the three M4 screws supplied with the mounting plate (position D in the figure above), tightening torque 1.8 Nm.
 Operating Instructions (compact) SCALANCE W-786 Operating Instructions,  ,    33  Connecting  4 4.1  Lightning protection, power supply, and grounding Notes on lightning protection  Warning  Antennas installed outdoors must be within the area covered by a lightning protection system. Make sure that all conducting systems entering from outdoors can be protected by a lightning protection potential equalization system. When implementing your lightning protection concept, make sure you adhere to the VDE 0182 or IEC 62305 standard.  A suitable lightning conductor is available in the range of accessories of SIMATIC NET Industrial WLAN:  Lightning Protector LP798-1PRO (order no. 6GK5798-1LP00-0AA6)  Warning  Installing this lightning protector between an antenna and a SCALANCE W7xx is not adequate protection against a lightning strike. The LP798-1PRO lightening protector only works within the framework of a comprehensive lightning protection concept. If you have questions, ask a qualified specialist company.   Note The requirements of EN61000-4-5, surge immunity tests on power supply lines, are met only when a Blitzductor is used with 24 V DC and 48 V DC: 24 V DC: VT AD 24V type no. 918 402  48 V DC: Type no. 919 545 and 919 506 (holder) Manufacturer: DEHN+SÖHNE GmbH+Co.KG Hans Dehn Str.1 Postfach 1640 D 92306 Neumarkt, Germany
Connecting   4.1 Lightning protection, power supply, and grounding  Operating Instructions (compact) SCALANCE W-786 34 Operating Instructions,  ,   Safety extra low voltage  Warning  SCALANCE W78x devices are designed for operation with a directly connectable safety extra-low voltage or with the power supply adapters available as accessories. Therefore only safety extra-low voltage (SELV) with limited power source (LPS) complying with IEC950/EN60950/VDE0805 may be connected to the power supply terminals (exception: Power supply adapter for 110 - 230 V AC). The power supply unit to supply the SCALANCE W788 / W74x must comply with NEC Class 2 (voltage range 18 - 32 V DC, current requirement 1 A) The power supply unit to supply the SCALANCE W786 must comply with NEC Class 2 (voltage 48 V DC, current requirement 0.3 A) The device may only be supplied by a power supply unit that meets the requirements of class 2 power sources of the "National Electrical Code, table 11 (b)". If the power supply is designed redundantly (two separate power supplies), both must meet these requirements. Exceptions: •  Power supply with PELV (according to VDE 0100-410) is also possible if the generated rated voltage does not exceed the voltage limits 25 V AC or 60 V DC. •  Power supply by a SELV power source (according to IEC 60950) or PELV power source (according to VDE 0100-410) without limited power is also permitted if suitable fire protection measures are taken by: –  Installation in a cabinet or suitable enclosure –  Installation in an appropriately equipped and closed operating area  Earthing  Caution  There must be no potential difference between the following parts otherwise there is a risk that the device will be destroyed: •  Ground potential of the power supply and ground potential of the antenna ground. •  Ground potential of the power supply and a grounded housing. •  Ground potential of the power supply and the ground potential of the device connected to Industrial Ethernet (for example PC, AS-300, AS-400 etc.) Connect both grounds to the same foundation earth or use an equipotential bonding cable.
 Connecting   4.2 Suitable cables for the SCALANCE W786 Operating Instructions (compact) SCALANCE W-786 Operating Instructions,  ,    35 4.2  Suitable cables for the SCALANCE W786 Cable specification The following table lists the requirements for a cable depending on the use case.  Application  Specification Direct 48 V DC supply  •  Round cable cross-section with 6 to 8 mm diameter. •  Permitted tensile load at least 100 N. Power supply adapter 12 - 24 V DC  •  Round cable cross-section with 6 to 8 mm diameter. •  Permitted tensile load at least 100 N. Power supply adapter 110 - 230 V AC  •  Round cable cross-section with 6 to 8 mm diameter. •  Three-core cable with 0.5 - 2.5 mm2 cross section of the individual cores. •  Permitted tensile load at least 100 N. Ethernet  IE FC TP Standard Cable GP 2 x 2 (type A) Order no. 6XV1 840-2AH10 IE TP Torsion Cable 2 x 2 (type C) Order no. 6XV1 870-2F IE FC TP Trailing Cable 2 x 2 (type C) Order no. 6XV1 840 3AH10 Multimode FO cable  FO Standard Cable GP Order no. 6XV1 873-2A Minimum bending radius 65 mm. You will find detailed information on preassembled cable lengths and connectors in the catalog "IK PI". Antenna connector  IWLAN antenna extension cable FRNC Length 5 m Order no. 6XV1 875-3FH50 Length 15 m Order no. 6XV1 875-3FN15
Connecting   4.3 Connecting the cables  Operating Instructions (compact) SCALANCE W-786 36 Operating Instructions,  ,   4.3  Connecting the cables Procedure  Warning  Danger from line voltage If the housing is not perfectly sealed, there is a danger to life due to the line voltage if the SCALANCE W786 is subjected to spray water or dampness. Make sure that you keep to the following safety rules. •  Before connecting up, turn of the power supply. •  The sealing of the cable feedthroughs of the SCALANCE W786 is only assured when the cable has a suitable diameter and adequate tensile strength. Only use cables that meet the specifications in the section "Cables for the SCALANCE W786". When connecting up a FO cable, make sure that you use the sealing sleeve supplied with the SCALANCE W786. •  Never wrap insulating tape, adhesive tape or other materials around thinner cables to achieve the required diameter. In this case, neither the housing seal nor the strain relief clamps can fulfill their function. •  Close all unused openings in the housing seal with the sealing plugs supplied with the SCALANCE W786. Do not use fillers or any other material under any circumstances.
 Connecting  4.3 Connecting the cables Operating Instructions (compact) SCALANCE W-786 Operating Instructions,  ,    37 &'$% Figure 4-1  Connecting a cable and fitting the strain relief clamps Follow the steps below to connect cables to the SCALANCE W786. 1.  Connect the cables to the appropriate contacts. (Position A in the figure above) You have the following options: – Connect cables preassembled with a connector (Ethernet, antennas) by inserting the connector into the appropriate socket. Secure antenna cables by tightening the sleeve nut of the connector (key size SW8). You will find more information on this topic in the sections "Connection for Industrial Ethernet" and "Connections for external antennas". – 48 V DC power supply. Use the connector supplied with the SCALANCE W786. For details of the terminal assignment, refer to the section "Connectors for the power supply". – 12 - 24 V DC or 110 - 230 V AC power supply. With these power supplies, you require a power supply adapter (do not ship with the SCALANCE W786). You will find more information in the section "Connecting a power supply adapter". 2.  Fit a strain relief clamp to the connected cable. The toothed part of the clamp must enclose the cable completely (as shown by position B in the figure above). 3.  Press the strain relief clamp into the housing until the cable is located completely in the opening in the housing seal (position C in the figure above).
Connecting   4.3 Connecting the cables  Operating Instructions (compact) SCALANCE W-786 38 Operating Instructions,  ,   4.  Seal all openings not required for cables with sealing plugs (position D in the figure above). There are two versions of sealing plug: Short type The upper end face of a dummy plug must be located below the cover plate (position E in the figure below). ( Figure 4-2  Location of the sealing plugs below the cover plate Long design Fit these sealing plugs in a strain relief clamp. The lower surrounding notch must be enclosed by the toothing of the strain relief clamp (as shown in the figure below). Press the strain relief clamp into the housing until the dummy plug is located completely in the opening of the housing seal.  Figure 4-3  Securing a long sealing plug with a strain relief clamp    Note Keep unused sealing plugs and strain relief clamps for later use.
 Connecting  4.3 Connecting the cables Operating Instructions (compact) SCALANCE W-786 Operating Instructions,  ,    39 Points to note when connecting an FO cable The FO cable specified for use with the SCALANCE W786 does not have a circular cross section. As a result, remember the following points when connecting up such cables. Sealing sleeve Fit the sealing sleeve at the point where the cable goes through the housing seal. Only then will you achieve perfect sealing of the housing. Follow the steps outlined below: $% Figure 4-4  Fitting a sealing sleeve to an FO cable 1.  Open the sealing sleeve as shown in the figure above and place the FO cable in it. 2.  Remove the protective foil (position A in the figure above) and join the sealing sleeve together (position B in the figure above). Strain relief clamp When you fit the strain relief clamp, make sure that the FO cable is in the correct position. The shorter sides of the cable must make contact with the toothing of the strain relief clamp.   Figure 4-5  View from above with an FO cable inserted in the strain relief clamp
Connecting   4.4 Connectors for the power supply of the SCALANCE W786  Operating Instructions (compact) SCALANCE W-786 40 Operating Instructions,  ,   4.4  Connectors for the power supply of the SCALANCE W786 Possible power supplies The following power supplies are suitable for the SCALANCE W786: ●  48 V DC direct voltage Use the two-pin connector supplied with the SCALANCE W786. ●  12 - 24 V DC direct voltage Use the power supply adapter 12 - 24 V DC available as an accessory. ●  110 - 230 V DC direct voltage Use the power supply adapter 110 - 230 V DC available as an accessory. ●  Power over Ethernet (PoE) PoE is possible only when voltage is modulated on the data lines (one of the two options named in IEEE 802.3af "phantom power") because all Ethernet cables specified for the SCALANCE W786 have four cores.
 Connecting   4.4 Connectors for the power supply of the SCALANCE W786 Operating Instructions (compact) SCALANCE W-786 Operating Instructions,  ,    41 Procedure for connecting the supplied connector for 48 V DC '&9 Figure 4-6  Position of the opening in the housing for the power supply with the housing cover removed Perform the following steps to connect a 48 V DC cable to a SCALANCE W786: 1.  Connect the supplied connector to the 48 V DC cable. The figure above shows the location of the socket in the housing and the contact assignment. The connector is safe against polarity reversal and can only be inserted in the right-hand half of the housing When connecting the cores, you should therefore make sure that the connector is oriented as shown in the following figure.  Figure 4-7  Position of the connector when inserted in the socket of the housing 2.  Press the connector into the socket in the housing until it engages. 3.  Secure the power cable with a strain relief clamp. For more detailed information on this topic, refer to the section "Connecting the cables".
Connecting   4.5 Connecting a power supply adapter  Operating Instructions (compact) SCALANCE W-786 42 Operating Instructions,  ,   4.5  Connecting a power supply adapter Input voltage options The optional power supply adapter is available in two versions: ●  Power supply adapter for 24 V DC direct voltage ●  Power supply adapter for 110 - 230 V AC alternating voltage    Note If a SCALANCE W786-3PRO is operated with diversity for three antenna pairs, the power for 24 V DC cannot be supplied redundantly. In this case, there is no further opening in the housing for a second power cable. How to fit the power supply adapter  Warning  Danger from line voltage Power supply cables may only be connected when the power is turned off! Start up the SCALANCE W786 only after screwing the housing cover in place again so that protection from touching live parts is restored!
 Connecting   4.5 Connecting a power supply adapter Operating Instructions (compact) SCALANCE W-786 Operating Instructions,  ,    43 9 9/00/ /13(%$ Figure 4-8  Using a power supply adapter in a SCALANCE W786 Follow the steps below to fit and connect a power supply adapter: 1.  Fit the power supply adapter in the SCALANCE W786 as shown in the figure above. The connector on the rear of the power supply adapter must engage fully in the socket of the housing. The entire rear surface of the power supply adapter must make contact with the inner surface of the SCALANCE W786.  Caution   Only use the loop (position B in the figure above) to remove the power supply adapter from the SCALANCE W786! This prevents the connector skewing on the back of the power supply adapter and breaking off. 2.  Connect the power supply adapter and the SCALANCE W786 with the screw supplied with the power supply adapter (position A in the figure above).
Connecting   4.5 Connecting a power supply adapter  Operating Instructions (compact) SCALANCE W-786 44 Operating Instructions,  ,   3.  Connect the cable for the power supply. The assignment of the contacts is illustrated in the figure above. 4.  Secure the power supply cable with a strain relief clamp. For more detailed information on this topic, refer to the section "Connecting the cables". How to remove the power supply adapter Follow the steps below to remove a power supply adapter from a SCALANCE W786:  Warning  Danger from line voltage Disconnect power supply cables only when the power to the power supply adapter is turned off!  1.  Disconnect the power supply cable from the power supply adapter. 2.  Loosen the securing screw of the power supply adapter (position A in the figure above). 3.  Pull the loop (position B in the figure above) to remove the connector on the rear of the power supply adapter from the socket in the housing and remove the power supply adapter.
 Connecting  4.6 Connection for Industrial Ethernet Operating Instructions (compact) SCALANCE W-786 Operating Instructions,  ,    45 4.6  Connection for Industrial Ethernet Device variants With a SCALANCE W786, you have the choice of two Ethernet ports: ●  RJ-45 jack ●  ST duplex socket for multimode FO cables 1310 nm and a maximum cable length of 3000 m Procedure for connecting an Ethernet cable 5;7;67'XSOH[ Figure 4-9  Position of the Ethernet port with the housing cover removed  Perform the following steps to connect an Ethernet cable to a SCALANCE W786: 1.  Insert the connector of the Ethernet cable in the corresponding socket of the SCALANCE W786. If you use FO cables, make sure that the transmit and receive lines are correctly connected. The location of the socket for RX and TX is shown in the figure above. 2.  Secure the Ethernet cable with a strain relief clamp. For more detailed information on this topic, refer to the section "Connecting the cables".
Connecting   4.7 Connectors for external antennas  Operating Instructions (compact) SCALANCE W-786 46 Operating Instructions,  ,   4.7  Connectors for external antennas How to connect external antennas $% Figure 4-10  Position of the ports for external antennas with the housing cover removed  For each WLAN port, there are two R-SMA sockets on a SCALANCE W786 to connect external antennas. The figure above shows how the R-SMA sockets are assigned to the WLAN ports. With a SCALANCE W786-1PRO, only the socket pair labeled "1" exists; with a SCALANCE W786-2PRO the sockets labeled "1" and "2" exist. Perform the following steps to connect a cable for an external antenna to a SCALANCE W786: 1.  Insert the connector on the antenna cable into the R-SMA socket and tighten the sleeve nut on the socket (key size SW8), tightening torque 0.6 Nm. If you want to use a port for two antennas, connect the line for antenna "B" first. After connecting the cable for antenna "A", the socket for "B" is not easy to reach. 2.  Screw a terminating resistor to the unused socket if you use only one antenna on a port. 3.  Secure the antenna cable(s) with a strain relief clamp. For more detailed information on this topic, refer to the section "Connecting the cables".
 Connecting  4.8 Inserting / removing the C-PLUG Operating Instructions (compact) SCALANCE W-786 Operating Instructions,  ,    47 4.8  Inserting / removing the C-PLUG Inserting the C-PLUG  Figure 4-11  Location of the C-PLUG with the housing cover removed  The housing of the C-PLUG has a protruding ridge on the long side. The C-PLUG can only be inserted when this ridge is at the top right. The slot in the SCALANCE W786 has a corresponding groove at this position. Make sure that the C-PLUG is inserted completely into the slot. Removing the C-PLUG Insert a screwdriver between the right-hand front edge of the C-PLUG and the slot and release the C-PLUG.
Connecting   4.8 Inserting / removing the C-PLUG  Operating Instructions (compact) SCALANCE W-786 48 Operating Instructions,  ,
 Operating Instructions (compact) SCALANCE W-786 Operating Instructions,  ,    49  Technical data  5 5.1  SCALANCE W786 technical specifications Data transfer  Ethernet transfer rate  10/100 Mbps Wireless transmission rate  1 ... 54 Mbps (108 Mbps) Wireless standards supported  802.1x 802.11a 802.11b 802.11e 802.11g 802.11h 802.11i Power supply standards supported  802.3af (Power over Ethernet) interfaces  Power  • 48 V DC supply via supplied connector • RJ-45 jack Power over Ethernet (48 V DC) • 2 x 24 V DC supplies with optional power supply adapter (available as accessory) • 110 - 230 V AC with optional power supply adapter (available as accessory) Data  • RJ-45 jack for Ethernet or on devices for FO cable: 1 x 2 BFOC sockets • depending on version, up to six R-SMA antenna sockets
Technical data   5.1 SCALANCE W786 technical specifications  Operating Instructions (compact) SCALANCE W-786 50 Operating Instructions,  ,   Electrical data  PoE  12.9 W 48 V DC  12.9 W  24 V DC (adapter)  15 W Power consumption depending on power supply 110 - 230 V AC (adapter) 15 W Construction  Dimensions (W x H x D) 251 mm x 251 mm x 72 mm Without power supply adapter 2241 g With power supply adapter 24 V DC 2428 g Weight (version with three IWLAN ports) With power supply adapter  110 - 230 V AC 2433 g Permitted ambient conditions  Operating temperature  -40°C ... 70°C Devices with fiber optic cable: -25°C ... 70°C Transport/storage temperature  -40°C ... 85°C Degree of protection  Tested to IP65 MTBF information (mean time between failure)  SCALANCE W786  MTBF 61 years
 Technical data  5.2 Permitted antennas Operating Instructions (compact) SCALANCE W-786 Operating Instructions,  ,    51 5.2  Permitted antennas Accessories for SCALANCE W-700   Note When you select an antenna, keep in mind the national approvals for your SCALANCE W7xx.    Characteristics  Type  Frequency / GHz Antenna gain / dBi Impedance / Ω  Order No. 2,4  6 Omni  ANT795-6MN 5  8 50  6GK5795-6MN00-0AA6 Omni  ANT792-6MN  2,4  6  50  6GK5792-6MN00-0AA6 Omni  ANT793-6MN  5  6  50  6GK5793-6MN00-0AA6 2,4  9 Patch  ANT795-6DN 5  9 50  6GK5795-6DN00-0AA6 Directional antenna ANT792-8DN  2,4  14  50  6GK5792-8DN00-0AA6 Directional antenna ANT793-8DN  5  18  50  6GK5793-8DN00-0AA6 Helix (for RCoax) ANT792-4DN  2,4  4  50  6GK5792-4DN00-0AA6 λ5/8 (for RCoax) ANT793-4MN  5  6    6GK5793-4MN00-0AA6 RCoax  IWLAN RCoax PE 1/2" 2.4 GHz 2,4  0  50  6XV1875-2A RCoax  IWLAN RCoax PE 1/2" 5 GHz 5  0  50  6XV1875-2D
Technical data   5.2 Permitted antennas  Operating Instructions (compact) SCALANCE W-786 52 Operating Instructions,  ,
 Operating Instructions (compact) SCALANCE W-786 Operating Instructions,  ,    53  Certification  6 6.1  Approvals for SCALANCE W786 CE conformity The products SIMATIC NET SCALANCE W786-1PRO SIMATIC NET SCALANCE W786-2PRO SIMATIC NET SCALANCE W786-3PRO in the version put into circulation by Siemens A&D meets the regulations of the following European directives: ●  99/5/EC Directive of the European Parliament and of the Council on radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity. Conformity with the basic requirement of the directive is attested by adherence to the following standards: ●  EN 60950 Safety of information technology equipment ●  EN 301489-1 Electromagnetic compatibility for radio equipment and services ●  EN 301489-17 Specific requirements for broadband data transmission systems and for equipment in local high-performance wireless networks (HIPERLAN) ●  EN 300328 Electromagnetic compatibility and radio spectrum issues ●  EN 301893 Broadband radio access networks (BRAN) – 5 GHz high-performance RLAN ●  EN 50371 Compliance of low power electronic and electrical apparatus with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz) ●  1999/519/EC Council recommendation on the limitation of exposure of the general public to electromagnetic fields (0 Hz to 300 GHz) Devices connected to the system must meet the relevant safety regulations.
Certification   6.1 Approvals for SCALANCE W786  Operating Instructions (compact) SCALANCE W-786 54 Operating Instructions,  ,   The EC Declaration of Conformity is available for the responsible authorities according to the above-mentioned EC Directive at the following address: Siemens Aktiengesellschaft Automation and Drives Industrielle Kommunikation Postfach 4848 D-90327 Nürnberg This declaration certifies compliance with the directives named above, but does not guarantee any specific properties.      Note The specified approvals apply only when the corresponding mark is printed on the product.
 Certification  6.1 Approvals for SCALANCE W786 Operating Instructions (compact) SCALANCE W-786 Operating Instructions,  ,    55 FCC approval This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. IEEE802.11b or g operation of this product in the USA is firmware-limited to channels 1 through11.  _________________________________________________________________________________ Notice Changes or modifications made to this equipment not expressly approved by SIEMENS may void the FCC authorization to operate this equipment. _________________________________________________________________________________  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ●  Reorient or relocate the receiving antenna. ●  Increase the separation between the equipment and receiver. ●  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. _________________________________________________________________________________ Notice This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator and your body. _________________________________________________________________________________ This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Professional Installation Notice:  To comply with FCC part 15 rules in the United States, the system must be professionally installed to ensure compliance with the Part 15 certification. It is the responsibility of the operator and professional installer to ensure that only certified systems are deployed in the United States. The use of the system in any other combination (such as co-located antennas transmitting the same information) is expressly forbidden.
Certification   6.1 Approvals for SCALANCE W786  Operating Instructions (compact) SCALANCE W-786 56 Operating Instructions,  ,   RSS-210 of Industry Canada "Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device." "This device has been designed to operate with the antennas listed below, and having a maximum gain of 18 dBi. Antennas not included in this list or having a gain greater than 18 dBi are strictly prohibited for use with this device. The required antenna impedance is 50 ohms." "To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that permitted for successful communication."  "That the device for the band 5150-5250 MHz is only for indoor usage to reduce potential for harmful interference to co-channel mobile satellite systems." "Users should also be cautioned to take note that high power radars are allocated as primary users (meaning they have priority) of 5250-5350 MHz and 5650-5850 MHz and these radars could cause interference and/or damage to LE-LAN devices."
 Certification   6.2 SCALANCE W786 national approvals Operating Instructions (compact) SCALANCE W-786 Operating Instructions,  ,    57 6.2  SCALANCE W786 national approvals National approvals Below, you will find the channels approved by the Institute of Electrical and Electronics Engineers, Inc. (IEEE) that can be used by SCALANCE W-786 devices for 802.11h mode. The channels approved for the standards 802.11a/b/g are not listed and are enabled for operation in specific countries based on the configuration. Countries in which there is no approval according to the IEEE 802.11h standard are not listed.  Column  Description Country  Country Mode  IEEE 802.11 standard and the TPC and / or DFS functionality, where required CH  Channel MHz  Frequency PWR (EIRP)  Maximum permitted effective isotropic radiated power Use  Permitted use indoors and / or outdoors  The SCALANCE W786 products are approved in the following countries:  Country  Mode  CH  MHz  PWR  (EIRP) Use Belgium   11b 11g g-Turbo   11a TPC11h DFS+TPCDFS+TPC1-1336-4836-64100-140 2412 - 2472  5180 - 5240  5180 - 5320 5500 - 5700 100 mW60 mW200 mW1000 mW Indoor only    Indoor only    Indoor only   Indoor + outdoor
Certification   6.2 SCALANCE W786 national approvals  Operating Instructions (compact) SCALANCE W-786 58 Operating Instructions,  ,   Country  Mode  CH  MHz  PWR  (EIRP) Use Denmark Germany Finland Great Britain Italy The Netherlands Austria Sweden Switzerland Spain  11b 11g g-Turbo   11a TPC11h DFS+TPCDFS+TPC1-1336-4836-64100-140 2412 - 2472  5180 - 5240  5180 - 5320 5500 - 5700 100 mW60 mW200 mW1000 mW Indoor + outdoor    Indoor only    Indoor only   Indoor + outdoor France  11b 11g g-Turbo      11a TPC11h DFS+TPCDFS+TPC1-78-1336-4836-64100-140 2412 - 2442 2447 - 2472  5180 - 5240  5180 - 5320 5500 - 5700 100 mW100 mW60 mW200 mW1000 mW Indoor + outdoor   Indoor only    Indoor only    Indoor only   Indoor + outdoor Canada  11b 11g g-Turbo   11a TPCTPC11a-Turbo TPCTPCTPC1-1136-48149-16542152160 2412 - 2462  5180 - 5240 5745 - 5825  5210 5760 5800 1000 mW200 mW1000 mW200 mW1000 mW1000 mW Indoor + outdoor    Indoor only   Indoor + outdoor     Indoor only Indoor + outdoor Indoor + outdoor
 Certification   6.2 SCALANCE W786 national approvals Operating Instructions (compact) SCALANCE W-786 Operating Instructions,  ,    59 Country  Mode  CH  MHz  PWR  (EIRP) Use United States of America   11b 11g g-Turbo   11a TPCTPC11a-Turbo TCPTPCTPC1-1136-48149-16542152160 2412 - 2462  5180 - 5240 5745 - 5825  5210 5760 5800 1000 mW200 mW1000 mW200 mW1000 mW1000 mW Indoor + outdoor    Indoor only   Indoor + outdoor     Indoor only Indoor + outdoor Indoor + outdoor
 Operating Instructions (compact) SCALANCE W-786 Operating Instructions,  ,    61  Index   C C-PLUG, 16 E Earthing, 34 I IEEE 802.11, 10 IEEE 802.11a, 10 IEEE 802.11b, 10 IEEE 802.11g, 10 L Lightning protection, 33 S Safety extra low voltage, 34

Navigation menu