Siemens MSN1V1 Industrial WLAN Access Point User Manual SCALANCE W774 1 W734 1

Siemens AG Industrial WLAN Access Point SCALANCE W774 1 W734 1

User Manual

Download: Siemens MSN1V1 Industrial WLAN Access Point User Manual SCALANCE W774 1 W734 1
Mirror Download [FCC.gov]Siemens MSN1V1 Industrial WLAN Access Point User Manual SCALANCE W774 1 W734 1
Document ID2241125
Application IDtVvMFeU6735ahvFnfDXoPA==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize224.15kB (2801839 bits)
Date Submitted2014-04-14 00:00:00
Date Available2014-04-15 00:00:00
Creation Date2013-07-05 13:41:49
Producing SoftwareAdobe PDF Library 10.0
Document Lastmod2014-04-02 16:42:50
Document TitleSCALANCE W774-1/W734-1
Document CreatorAcrobat PDFMaker 10.1 für Word
Document Author: Siemens AG

SCALANCE W774-1/W734-1
___________________
Information on the Internet
___________________
Introduction
SIMATIC NET
Industrial Wireless LAN
SCALANCE W774-1/W734-1
___________________
Description
___________________
Mounting
___________________
Connection
___________________
Technical data
Operating Instructions
Approvals
07/2013
C79000-G8976-C325-01
Legal information
Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent
damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert
symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are
graded according to the degree of danger.
DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
indicates that minor personal injury can result if proper precautions are not taken.
NOTICE
indicates that property damage can result if proper precautions are not taken.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will
be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to
property damage.
Qualified Personnel
The product/system described in this documentation may be operated only by personnel qualified for the specific
task in accordance with the relevant documentation, in particular its warning notices and safety instructions.
Qualified personnel are those who, based on their training and experience, are capable of identifying risks and
avoiding potential hazards when working with these products/systems.
Proper use of Siemens products
Note the following:
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical
documentation. If products and components from other manufacturers are used, these must be recommended
or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and
maintenance are required to ensure that the products operate safely and without any problems. The permissible
ambient conditions must be complied with. The information in the relevant documentation must be observed.
Trademarks
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication
may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software
described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the
information in this publication is reviewed regularly and any necessary corrections are included in subsequent
editions.
Siemens AG
Industry Sector
Postfach 48 48
90026 NÜRNBERG
GERMANY
Order number: C79000-G8976-C325-01
Ⓟ 07/2013 Technical data subject to change
Copyright © Siemens AG 2013.
All rights reserved
Contents
Information on the Internet ...................................................................................................................... 5
Introduction ............................................................................................................................................. 7
2.1
Information on the Operating Instructions SCALANCE W774/W734 ............................................7
2.2
Structure of the type designation ................................................................................................... 8
2.3
Security information ....................................................................................................................... 8
Description .............................................................................................................................................. 9
3.1
Components of the product............................................................................................................ 9
3.2
LED display ..................................................................................................................................10
3.3
Reset button .................................................................................................................................12
Mounting ............................................................................................................................................... 13
4.1
Access restriction due to high housing temperature ....................................................................13
4.2
Wall mounting ..............................................................................................................................14
4.3
Installing on an S7-300 standard rail ...........................................................................................16
4.4
Installing on an S7-1500 standard rail .........................................................................................17
4.5
Installing on a DIN rail / removing ................................................................................................18
Connection ........................................................................................................................................... 21
5.1
Lightning protection, power supply and grounding ......................................................................21
5.2
Power supply................................................................................................................................25
5.3
Ethernet ........................................................................................................................................26
5.4
Suitable cables for power supply and Ethernet ...........................................................................27
5.5
Antenna connectors .....................................................................................................................28
5.6
Suitable antenna cables and antennas ........................................................................................29
5.7
C-PLUG/KEY-PLUG ....................................................................................................................31
Technical data ...................................................................................................................................... 33
6.1
Dimensional drawing ....................................................................................................................35
Approvals.............................................................................................................................................. 37
7.1
SCALANCE W774/W734 national approvals ..............................................................................42
SCALANCE W774-1/W734-1
Operating Instructions, 07/2013, C79000-G8976-C325-01
Information on the Internet
Bitte beachten Sie die Warnhinweise und zusätzlichen Informationen in der
Kompaktbetriebsanleitung in Ihrer Sprache im Internet:
http://support.automation.siemens.com/ww/view/at/10806097
http://support.automation.siemens.com/ww/view/ch/10806097
http://support.automation.siemens.com/ww/view/de/10806097
http://support.automation.siemens.com/ww/view/li/10806097
http://support.automation.siemens.com/ww/view/lu/10806097
Please observe the warnings and additional information in the compact operating
instructions in your language in the Internet:
http://support.automation.siemens.com/ww/view/au/10806097
http://support.automation.siemens.com/ww/view/ca/10806097
http://support.automation.siemens.com/ww/view/gb/10806097
http://support.automation.siemens.com/ww/view/ie/10806097
http://support.automation.siemens.com/ww/view/us/10806097
http://support.automation.siemens.com/ww/view/za/10806097
Veuillez tenir compte des avertissements et informations supplémentaires de la notice de
service dans votre langue sur Internet:
http://support.automation.siemens.com/ww/view/be/10806097
http://support.automation.siemens.com/ww/view/ch/10806097
http://support.automation.siemens.com/ww/view/fr/10806097
http://support.automation.siemens.com/ww/view/lu/10806097
Si prega di tenere conto delle avvertenze e ulteriori informazioni nell’istruzione operativa
compatta nella relativa lingua in Internet:
http://support.automation.siemens.com/ww/view/it/10806097
Se ruega tener en cuenta las advertencias y las informaciones complementarias contenidas
en las instrucciones de servicio (resumen) en español en Internet:
http://support.automation.siemens.com/ww/view/cl/10806097
http://support.automation.siemens.com/ww/view/es/10806097
Dbejte prosím na výstražné pokyny a doplňkové informace v kompaktním návodu k obsluze
ve vašem jazyce na internetu:
http://support.automation.siemens.com/ww/view/cz/10806097
Vær venligst opmærksom på de advarselsanvisninger og ekstra informationer der findes på
dit sprog i kompaktdriftsvejledningen på internettet:
http://support.automation.siemens.com/ww/view/dk/10806097
Noudata lyhyen käyttöoppaan sisältämiä varoituksia ja huomio sen muutkin tiedot. Oman
kielisesi käyttöoppaan löydät internetistä osoitteesta:
http://support.automation.siemens.com/ww/view/fi/10806097
Λάβετε υπόψη τις υποδείξεις προειδοποίησης και τις πρόσθετες πληροφορίες των
συνοπτικών οδηγιών χρήσης που παρέχονται στη γλώσσα σας στο Διαδίκτυο:
http://support.automation.siemens.com/ww/view/gr/10806097
SCALANCE W774-1/W734-1
Operating Instructions, 07/2013, C79000-G8976-C325-01
Information on the Internet
请注意互联网上精编版操作说明相应语言版本中的警告提示和附加信息:
http://support.automation.siemens.com/ww/view/cn/10806097
http://support.automation.siemens.com/ww/view/hk/10806097
http://support.automation.siemens.com/ww/view/sg/10806097
Kérjük, vegye figyelembe az interneten található, az Ön anyanyelvén íródott kompakt
használati útmutatóban található figyelmeztetéseket és további információkat:
http://support.automation.siemens.com/ww/view/hu/10806097
Skoðið vel viðvaranir og aðrar upplýsingar í notkunarleiðbeiningunum á ykkar tungumáli á
internetinu:
http://support.automation.siemens.com/ww/view/is/10806097
インターネットサイトにある各言語の注意事項および追加情報を参照してください:
http://support.automation.siemens.com/ww/view/jp/10806097
사이트에 있는 귀하의 언어로 된 콤팩트 사용 설명서에 명시된 경고 지침 및 추가 정보를
준수하십시오:
http://support.automation.siemens.com/ww/view/kr/10806097
http://support.automation.siemens.com/ww/view/kw/10806097
Neem goed nota van de waarschuwingen en extra informatie in de compacte
gebruiksaanwijzing in uw taal op internet:
http://support.automation.siemens.com/ww/view/be/10806097
http://support.automation.siemens.com/ww/view/nl/10806097
Vennligst følg advarslene og annen informasjon i den kompakte bruksanvisningen, som du
finner på ditt språk på internett:
http://support.automation.siemens.com/ww/view/no/10806097
Proszę zwrócić uwagę na ostrzeżenia oraz dodatkowe informacje w kompaktowej instrukcji
obsługi, dostępnej w odpowiednim języku w internecie:
http://support.automation.siemens.com/ww/view/po/10806097
Observera varningshänvisningarna och extrainformationerna i kompaktbruksanvisningen
som finns på ditt språk på internet:
http://support.automation.siemens.com/ww/view/se/10806097
İnternette kendi dilinizdeki kompakt işletim kılavuzunda yer alan uyarı notlarına ve ek
bilgilere lütfen dikkat edin:
http://support.automation.siemens.com/ww/view/tr/10806097
SCALANCE W774-1/W734-1
Operating Instructions, 07/2013, C79000-G8976-C325-01
2
Introduction
2.1
Information on the Operating Instructions SCALANCE W774/W734
Validity of the Operating Instructions
These operating instructions cover the following products:
Order no.
Order no. of the US version:
6GK5774-1FX00-0AA0
6GK5774-1FX00-0AB0
6GK5734-1FX00-0AA0
6GK5734-1FX00-0AB0
Access point
SCALANCE W774-1 RJ-45
Ethernet client modules
SCALANCE W734-1 RJ-45
These operating instructions apply to the following software version:
● SCALANCE W774/W734 firmware as of Version 3.0
Purpose of the Operating Instructions
Based on the operating instructions, you will be able to install and connect up the
SCALANCE W774/W734 correctly. The configuration and the integration of the device in a
WLAN are not described in these instructions.
Documentation on the accompanying CD
You will find detailed information about configuration in the SCALANCE W700 configuration
manuals on the accompanying SIMATIC NET IWLAN CD under the file name:
PH_SCALANCE-W77x-W73x-WBM_76.pdf and PH_SCALANCE-W77x-W73x-CLI_76.pdf
Note
Make sure that you read the explanations and instructions in the README.txt file
SCALANCE W774-1/W734-1
Operating Instructions, 07/2013, C79000-G8976-C325-01
Introduction
2.2 Structure of the type designation
2.2
Structure of the type designation
The type designation of the device is made up of several parts that have the following
meaning:
2.3
Security information
Siemens provides automation and drive products with industrial security functions that
support the secure operation of plants or machines. They are an important component in a
holistic industrial security concept. With this in mind, our products undergo continuous
development. We therefore recommend that you keep yourself informed with respect to our
product updates. Please find further information and newsletters on this subject at:
http://support.automation.siemens.com.
To ensure the secure operation of a plant or machine it is also necessary to take suitable
preventive action (e.g. cell protection concept) and to integrate the automation and drive
components into a state-of-the-art holistic industrial security concept for the entire plant or
machine. Any third-party products that may be in use must also be taken into account.
Please find further information at: http://www.siemens.com/industrialsecurity
SCALANCE W774-1/W734-1
Operating Instructions, 07/2013, C79000-G8976-C325-01
Description
3.1
Components of the product
The following components are supplied with the product:
● SCALANCE W774 or SCALANCE W734
● 2 protective caps for the antenna sockets
● 1 connector for the power supply
● 1 screw for mounting on an S7-300 standard rail or S7-1500 standard rail
● SCALANCE W774/W734 safety notices in printed form
● SIMATIC NET Industrial Wireless LAN CD
Please check that the consignment you have received is complete. If the consignment is
incomplete, contact your supplier or your local Siemens office.
SCALANCE W774-1/W734-1
Operating Instructions, 07/2013, C79000-G8976-C325-01
Description
3.2 LED display
3.2
LED display
Information on operating status and data transfer
On the front of the housing, several LEDs provide information on the operating status of the
device:
LED
Color
Meaning
L1
Green
Power supply L1.
L2
Green
Power supply L2.
PoE
Green
Power supply using Power over Ethernet.
P1
Flashing yellow
Data transfer via the first Ethernet interface.
Green
There is a connection via the first Ethernet interface (Link).
Flashing yellow
Data transfer via the second Ethernet interface.
Green
There is a connection via the second Ethernet interface (Link).
P2
SCALANCE W774-1/W734-1
10
Operating Instructions, 07/2013, C79000-G8976-C325-01
Description
3.2 LED display
R1
Flashing yellow
Green
Data transfer over the WLAN interface.
SCALANCE W774 in access point mode:
The WLAN interface is initialized and ready for operation.
SCALANCE W774 in client mode or SCALANCE W734:
There is a connection via the WLAN interface.
Flashing green
Green
flashing briefly
SCALANCE W774 in client mode or SCALANCE W734:
The client is searching for a connection to an access point.
SCALANCE W774 in access point mode:
With 802.11h, the channel is scanned for one minute for primary users
before the channel can be used for data traffic.
SCALANCE W774 in client mode or SCALANCE W734:
The client waits for the MAC address due to the setting "Automatic" for
the "MAC mode" parameter and is connected to no access point.
P1
R1
Green
flashing 3 x
short, 1 x long
SCALANCE W774 in client mode or SCALANCE W734:
Red
An error occurred during operation with the device.
Red
R1 flashing
green at the
same time
A primary user was found on all enabled channels.
Flashing yellow
and green
simultaneously.
"Flashing" enabled using SIMATIC NET Primary Setup Tool (PST).
The client waits for the MAC address due to the setting "Automatic" for
the "MAC mode" parameter and is connected to an access point.
Note
Primary user (radar) on all enabled channels
If the device detects a primary user (for example radar signals) on all enabled channels of
the WLAN interface, the LED F is lit and R1 flashes. No data traffic is then possible for the
next 30 minutes. After this time, the device runs the scan again and checks whether a
primary user still exists. If no primary user is detected, data traffic is possible again.
The wait time of 30 minutes is necessary due to legal requirements and cannot be shortened
even by restarting the device.
SCALANCE W774-1/W734-1
Operating Instructions, 07/2013, C79000-G8976-C325-01
11
Description
3.3 Reset button
3.3
Reset button
The reset button (position ①) is on the top of the housing:
Functions of the reset button
The reset button has the following functions:
● Restart of the device
To restart the device, press the Reset button briefly.
● Loading new firmware
If the normal procedure with the "Load & Save" menu of Web Based Management is
unsuccessful, the reset button can be used to load new firmware. This situation can occur
if there is a power outage during the normal firmware update. You will find more detailed
information in the configuration manual SCALANCE W77x/W73x WBM.
● Restoring the default parameters (factory defaults)
You will find more detailed information in the configuration manual SCALANCE
W77x/W73x WBM.
SCALANCE W774-1/W734-1
12
Operating Instructions, 07/2013, C79000-G8976-C325-01
4
Mounting
4.1
Access restriction due to high housing temperature
WARNING
If a device is operated in an ambient temperature of more than 50 °C, the temperature of
the device housing may be higher than 70 °C. The device must therefore be installed so
that it is only accessible to service personnel or users that are aware of the reason for
restricted access and the required safety measures at an ambient temperature higher than
50 °C.
WARNING
When used in hazardous environments corresponding to Class I, Division 2 or Class I,
Zone 2, the device must be installed in a cabinet or a suitable enclosure.
General notes on use according to ATEX
WARNING
To comply with EU Directive 94/9 (ATEX95), this enclosure must meet the requirements of
at least IP54 in compliance with EN 60529.
SCALANCE W774-1/W734-1
Operating Instructions, 07/2013, C79000-G8976-C325-01
13
Mounting
4.2 Wall mounting
4.2
Wall mounting
Drilling template
The location of the holes for mounting the SCALANCE W774/W734 on a wall is shown in the
following figure:
SCALANCE W774-1/W734-1
14
Operating Instructions, 07/2013, C79000-G8976-C325-01
Mounting
4.2 Wall mounting
Procedure
Secure the device to the wall with two screws. The screws are not supplied with the device.
The type and length of the screws depend on the type of wall.
SCALANCE W774-1/W734-1
Operating Instructions, 07/2013, C79000-G8976-C325-01
15
Mounting
4.3 Installing on an S7-300 standard rail
4.3
Installing on an S7-300 standard rail
Procedure
Follow the steps below to fit the SCALANCE W744/W734 to an S7-300 standard rail:
1. Place the device on the upper edge of the S7-300 standard rail as shown in the figure.
2. Screw the housing to the S7-300 standard rail. The required screw ships with the
SCALANCE W744/W734.
SCALANCE W774-1/W734-1
16
Operating Instructions, 07/2013, C79000-G8976-C325-01
Mounting
4.4 Installing on an S7-1500 standard rail
4.4
Installing on an S7-1500 standard rail
Procedure
Follow the steps below to fit the SCALANCE W744/W734 to an S7-1500 standard rail:
1. Place the device on the upper edge of the S7-1500 standard rail as shown in the figure.
2. Screw the housing to the S7-1500 standard rail. The required screw ships with the
device.
SCALANCE W774-1/W734-1
Operating Instructions, 07/2013, C79000-G8976-C325-01
17
Mounting
4.5 Installing on a DIN rail / removing
4.5
Installing on a DIN rail / removing
Procedure for installation
Follow the steps below to fit the SCALANCE W744/W734 to a DIN rail:
1. Place the device on the upper edge of the DIN rail as shown in the figure.
2. Press the device against the DIN rail until the DIN rail slider catch locks in place.
SCALANCE W774-1/W734-1
18
Operating Instructions, 07/2013, C79000-G8976-C325-01
Mounting
4.5 Installing on a DIN rail / removing
Procedure when removing
Follow the steps below to remove the SCALANCE W744/W734 from a DIN rail:
1. Pull the DIN rail slider down with a screwdriver.
2. Tilt the SCALANCE W774/W734 forward and remove the device from the DIN rail.
SCALANCE W774-1/W734-1
Operating Instructions, 07/2013, C79000-G8976-C325-01
19
Mounting
4.5 Installing on a DIN rail / removing
SCALANCE W774-1/W734-1
20
Operating Instructions, 07/2013, C79000-G8976-C325-01
5
Connection
5.1
Lightning protection, power supply and grounding
Notes on lightning protection
WARNING
Danger due to lightning strikes
Antennas installed outdoors must be within the area covered by a lightning protection
system. Make sure that all conducting systems entering from outdoors can be protected by
a lightning protection potential equalization system.
When implementing your lightning protection concept, make sure you adhere to the VDE
0182 or IEC 62305 standard.
Suitable lightning protectors are available in the range of accessories of SIMATIC NET
Industrial WLAN:
● Lightning protector LP798-1N (order no. 6GK5798-2LP00-2AA6)
● Lightning protector LP798-2N (order no. 6GK5798-2LP10-2AA6)
Note
We recommend that you use the maintenance-free lightning protector LP798-2N.
Exception: When there is also DC power is supplied via the antenna cable. In this case, only
the lightning protector LP798-1N can be used.
WARNING
Danger due to lightning strikes
Installing this lightning protector between an antenna and a SCALANCE W700 is not
adequate protection against a lightning strike. The LP798-1N lightening protector only
works within the framework of a comprehensive lightning protection concept. If you have
questions, ask a qualified specialist company.
SCALANCE W774-1/W734-1
Operating Instructions, 07/2013, C79000-G8976-C325-01
21
Connection
5.1 Lightning protection, power supply and grounding
Note
The requirements of EN61000-4-5, surge immunity tests on power supply lines, are met only
when a Blitzductor is used with 12 to 24 VDC:
12 to 24 VDC: VT AD 24V type no. 918 402
Vendor: DEHN+SÖHNE GmbH+Co.KG, Hans Dehn Str. 1, Postfach 1640, D 92306 Neumarkt, Germany
Safety extra low voltage
WARNING
Danger to life from overvoltage, fire hazard
SCALANCE W700 devices are designed for operation with a directly connectable safety
extra-low voltage or with the power supply adapters available as accessories (available
only for the SCALANCE W786 device). Therefore only safety extra-low voltage (SELV) with
limited power source (LPS) complying with IEC950/EN60950/VDE0805 may be connected
to the power supply terminals (exception: Power supply adapter for 100 - 240 VAC for the
SCALANCE W786).
Take measures to prevent transient overvoltage of more than 40% of the rated voltage.
This criterion is fulfilled, if devices are operated solely with SELV (Safety Extra-Low
Voltage).
The power supply unit to supply the SCALANCE W700 must comply with NEC Class 2
(requirements of class 2 for power supply units of the "National Electrical Code, table 11
(b)") or SELV with LPS (Limited Power Source) EN 60950-1. If the power supply is
designed redundantly (two separate power supplies), both power supplies must meet these
requirements.
Exception:
Power supply with PELV (according to VDE 0100-410 or IEC 60364-4-41) is also possible if
the generated rated voltage does not exceed the voltage limits 25 VAC or 60 VDC.
SCALANCE W774-1/W734-1
22
Operating Instructions, 07/2013, C79000-G8976-C325-01
Connection
5.1 Lightning protection, power supply and grounding
Grounding
NOTICE
Damage to the device due to potential differences
To fully eliminate the influence of electromagnetic interference, the device must be
grounded. There must be no potential difference between the following parts, otherwise the
device or other connected device could be severely damaged:
• Housing of the SCALANCE W700 and the ground potential of the antenna.
• Housing of the SCALANCE W700 and the ground potential of a device connected over
Ethernet.
• Housing of the SCALANCE W700 and the shield contact of the connected Ethernet
cable.
Connect both grounds to the same foundation earth or use an equipotential bonding cable.
If it is used outdoors, the device must always be connected to protective earth.
WARNING
EXPLOSION HAZARD
SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION
2 OR ZONE 2.
WARNING
EXPLOSION HAZARD
DO NOT OPEN WHEN ENERGIZED.
General notes on use according to ATEX
WARNING
EXPLOSION HAZARD
DO NOT CONNECT OR DISCONNECT EQUIPMENT WHEN A FLAMMABLE OR
COMBUSTIBLE ATMOSPHERE IS PRESENT.
SCALANCE W774-1/W734-1
Operating Instructions, 07/2013, C79000-G8976-C325-01
23
Connection
5.1 Lightning protection, power supply and grounding
General notes on use in hazardous areas according to UL-HazLoc
WARNING
EXPLOSION HAZARD
DO NOT DISCONNECT WHILE CIRCUIT IS LIVE UNLESS AREA IS KNOWN TO BE
NON-HAZARDOUS.
This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D or nonhazardous locations only.
This equipment is suitable for use in Class I, Zone 2, Group IIC or non-hazardous locations
only.
SCALANCE W774-1/W734-1
24
Operating Instructions, 07/2013, C79000-G8976-C325-01
Connection
5.2 Power supply
5.2
Power supply
For the power supply, there are two options with the SCALANCE W774/W734:
● Direct feed in via the four-pin socket (position ①)
● Power over Ethernet via the Ethernet interface P2 (position ②). The other Ethernet
interface P1 is not capable of PoE.
Socket
The four-pin connecting socket has the following pin assignment:
Pin
Assignment
L1+
24 VDC
M1
Ground
M2
Ground
L2+
24 VDC
Power over Ethernet
The SCALANCE W774/W734 supports the standards 802.3at type 1 (IEEE 802.3af ) and
IEEE 803.at type 2.
● Gigabit Ethernet
When you connect to gigabit Ethernet, the power supply is a phantom power supply over
data wires 1, 2, 3 and 6. This corresponds to alternative A according to IEEE 802.3af.
● Fast Ethernet
On an 8-wire Fast Ethernet cable, the power is supplied via the free data wires 4, 5, 7
and 8. This corresponds to alternative B according to IEEE 802.3af.
SCALANCE W774-1/W734-1
Operating Instructions, 07/2013, C79000-G8976-C325-01
25
Connection
5.3 Ethernet
Note
No power sourcing equipment (PSE)
The SCALANCE W774/W734 cannot be used as a PoE power supply for other devices.
5.3
Ethernet
The SCALANCE W774/W734 has two Ethernet interfaces located on the underside of the
device.
①
②
Ethernet interface P1
Ethernet interface P2
The power can also be supplied via this interface (Power over Ethernet).
SCALANCE W774-1/W734-1
26
Operating Instructions, 07/2013, C79000-G8976-C325-01
Connection
5.4 Suitable cables for power supply and Ethernet
5.4
Suitable cables for power supply and Ethernet
Cable specification
The following table lists the requirements for a cable depending on the application.
Application
Specification
Direct 24 VDC supply
•
Round cable cross-section with
6 to 8 mm diameter.
Two-wire cable with 0.5 to 1.5 mm2 cross-section
per wire.
•
Permitted tensile load at least
100 N.
•
UL listing: Type PLTC or ITC
Ethernet
1. IE FC TP standard cable GP 2 x 2 (type A)
Order no.: 6XV1 840-2AH10
2. IE TP torsion cable 2 x 2 (type C)
Order no.: 6XV1 870-2F
3. IE FC TP trailing cable 2 x 2 (type C)
Order no.: 6XV1 840 3AH10
UL listing: Type PLTC or ITC (the three named types
have this approval)
WARNING
Only use cables suitable for high temperatures!
If temperatures in excess of 70 °C occur on the cable or at the housing socket, or the
temperature at the branching points of the cables exceeds 80 °C, special measures need to
be taken.
If the equipment is operated in an air ambient at 45 - 60 °C, only use cables with admitted
maximum operating temperature of at least 90 °C.
SCALANCE W774-1/W734-1
Operating Instructions, 07/2013, C79000-G8976-C325-01
27
Connection
5.5 Antenna connectors
5.5
Antenna connectors
The SCALANCE W774/W734 has two antenna connectors of the type R-SMA located on the
top of the device.
①
②
Antenna connector R1 A1
Antenna connector R1 A2
Procedure
Follow the steps below to connect a cable for an external antenna to a SCALANCE
W774/W734:
1. Insert the connector on the antenna cable into the R-SMA socket and tighten the sleeve
nut on the socket (key size SW8, tightening torque 0.6 Nm). If you only use one antenna,
you need to connect this to the device via antenna connector R1 A1 (position ①).
2. Screw a terminating resistor to the unused antenna socket R1 R2 (position ②) if you are
only using one antenna.
Note
Cabinet installation
When installing the SCALANCE W774/734 in a cabinet, you need to use detached antennas.
Suitable connecting cable for a connection between SCALANCE W774/w734 and a
detached antenna are available from SIMATIC NET. You will find detailed information in the
following section.
SCALANCE W774-1/W734-1
28
Operating Instructions, 07/2013, C79000-G8976-C325-01
Connection
5.6 Suitable antenna cables and antennas
5.6
Suitable antenna cables and antennas
N-Connect/R-SMA connecting cable
To connect an antenna with an N-Connector to a SCALANCE W774/734, the following
cables are suitable:
Length
Order number
0.3 m
6XV1875-5CE30
1m
6XV1875-5CH10
2m
6XV1875-5CH20
5m
6XV1875-5CH50
10 m
6XV1875-5CN10
Suitable antennas
Note
When you select an antenna, keep in mind the national approvals for your SCALANCE
W774/W734.
Type
Properties
Order number
ANT792-6MN
Omni antenna, mast/wall mounting, 6 dBi
2.4 GHz, N-Connect female
6GK5 792-6MN00-0AA6
ANT793-6MN
Omni antenna, mast/wall mounting, 5 dBi
5 GHz, N-Connect female
6GK5 793-6MN00-0AA6
ANT792-8DN
Directional antenna, mast/wall mounting,
14 dBi
2.4 GHz, N-Connect female
6GK5 792-8DN00-0AA6
ANT793-8DJ
Directional antenna, mast/wall mounting,
18 dBi
5 GHz, 2 x N-Connect female
6GK5 793-8DJ00-0AA0
ANT793-8DK
Directional antenna, mast/wall mounting,
23 dBi
5 GHz, 2 x N-Connect female
6GK5 793-8DK00-0AA0
ANT793-8DP
Directional antenna, mast/wall mounting,
13 dBi
5 GHz, N-Connect female
6GK5793-8DP00-0AA0
ANT795-6DC
Wide angle antenna, mast/
wall mounting, 9 dBi
2.4 GHz and 5 GHz, N-Connect female
6GK5 795-6DC00-0AA0
ANT793-6DG
Wide angle antenna, mast/
wall mounting, 9 dBi
5 GHz, 2 x N-Connect female
6GK5 793-6DG00-0AA0
SCALANCE W774-1/W734-1
Operating Instructions, 07/2013, C79000-G8976-C325-01
29
Connection
5.6 Suitable antenna cables and antennas
Type
Properties
Order number
ANT795-6MN
Omni antenna, mounted on roof/vehicle,
6/8 dBi
2.4 GHz and 5 GHz, N-Connect female
6GK5 795-6MN10-0AA6
ANT795-4MA
Omni antenna, 3/5 dBi
2.4 GHz and 5 GHz, IP30, R-SMA
connector male for direct mounting on the
device, connector angle adjustable 0° to
180°.
6GK5 795-4MA00-0AA3
ANT792-4DN
RCoax helical antenna, circular
polarization, 4 dBi, 2.4 GHz, N-connect
female.
6GK5 792-4DN00-0AA6
ANT793-4MN
RCoax λ5/8 antenna with vertical
polarization, 6 dBi, 5 GHz, N-connect
female.
6GK5 793-4MN00-0AA6
IWLAN RCoax cable 2.4 Omni antenna, 0 dBi
GHz PE 1/2"
2.400 - 2.485 GHz, N-Connect female.
6XV1875-2A
IWLAN RCoax cable 5
GHz PE 1/2"
6XV1875-2D
Omni antenna, 0 dBi
5.150 - 5.875 GHz, N-Connect female.
SCALANCE W774-1/W734-1
30
Operating Instructions, 07/2013, C79000-G8976-C325-01
Connection
5.7 C-PLUG/KEY-PLUG
5.7
C-PLUG/KEY-PLUG
The C-PLUG/KEY-PLUG slot is on the top of the SCALANCE W774/734 housing.
NOTICE
Do not replace the PLUG during operation
A PLUG may only be removed or inserted when the device is turned off.
Removing the PLUG
Follow the steps below to remove a PLUG from a SCALANCE W774/734:
1. Turn off the power to the device.
2. Release the screw slot cover (position ①) and swing the slot cover to the side (position
②).
3. Insert a screwdriver between the front edge of the PLUG (Position ③) and the slot and
release the PLUG.
Inserting the PLUG
Follow the steps below to insert a PLUG in a SCALANCE W774/734:
1. Turn off the power to the device.
2. The housing of the PLUG has a protruding ridge on the long side (position ④). The slot
has a groove at this position. Insert the PLUG correctly oriented into the slot. The PLUG
is correctly inserted when it is completely inside the device and does not jut out of the
slot.
SCALANCE W774-1/W734-1
Operating Instructions, 07/2013, C79000-G8976-C325-01
31
Connection
5.7 C-PLUG/KEY-PLUG
3. Close the slot cover (position ②).
4. Tighten the screw at position ① to secure the slot cover.
SCALANCE W774-1/W734-1
32
Operating Instructions, 07/2013, C79000-G8976-C325-01
6
Technical data
SCALANCE W774/W734
Attachment to Industrial Ethernet
Quantity
Design
RJ-45 jack
Properties
10/100BASE-T, IEEE 802, half duplex/full duplex, autocrossover, autonegotiation,
autosensing, PoE, floating
Transmission speed
10 / 100 Mbps
Permitted cable lengths (Ethernet)
(Alternative combinations per length
range) *
0 ... 55 m
•
Max. 55 m IE TP Torsion Cable
with IE FC RJ45 Plug 180
•
Max. 45 m IE TP Torsion Cable
with IE FC RJ45 + 10 m TP Cord
via IE FC RJ45 Outlet
•
Max. 85 m IE FC TP
Marine/Trailing/Flexible/FRNC/Fe
stoon/Food Cable with
IE FC RJ45 Plug 180
•
Max. 75 m IE FC TP
Marine/Trailing/Flexible/FRNC/Fe
stoon/Food Cable + 10 m
TP Cord via IE FC RJ45 Outlet
•
Max. 100 m IE FC TP Standard
Cable with IE FC RJ45 Plug 180
•
Max. 90 m IE FC TP Standard
Cable + 10 m TP Cord via
IE FC RJ45 Outlet
0 ... 85 m
0 ... 100 m
Wireless interface
Antenna connector
Quantity
Design
R-SMA female
Impedance
Frequency range
50 Ω nominal
2412 ... 2500 MHz
4920 ... 5875 MHz
Electrical data
Power supply
Supply voltage
24 VDC Safe Extra Low Voltage (SELV)
Permitted range
19.2 to 28.8 VDC
Design
Terminal block, 4 terminals
SCALANCE W774-1/W734-1
Operating Instructions, 07/2013, C79000-G8976-C325-01
33
Technical data
Properties
Electrically isolated, redundant design
PoE to 24 VDC non-redundant design
From PoE
Fusing
Current consumption
36 to 57 VDC
2 A / 24 VDC
Typical
xxx mA
Maximum
xxx mA
Typical
xxx W
Maximum
xxx W
During operation with the rack
installed horizontally
-20 ℃ to +60 ℃
During operation with the rack
installed vertically
-20 ℃ to +60 ℃
During operation
-40 ℃ to +70 ℃
During storage
-40 ℃ to +70 ℃
During transportation
-40 ℃ to +70 ℃
Relative humidity
During operation
≤ 95% at 25 °C, no condensation
Operating altitude
During operation
≤ 2,000 m above sea level at max. 60 °C
ambient temperature
Contaminant concentration
According to IEC 60721
Power loss at 24 VDC
Permitted ambient conditions
Ambient temperature
Design, dimensions and weight
Degree of protection
IP30
Weight
xxx g
Dimensions (W x H x D)
26 x 147 (without antenna sockets) x 127 mm
Installation options
•
Wall mounting
•
Installation on a DIN rail
•
Installation on an S7-300 standard rail
•
Installation on an S7-1500 standard rail
Other properties
MTBF
SCALANCE W774-1/W734-1
34
Operating Instructions, 07/2013, C79000-G8976-C325-01
Technical data
6.1 Dimensional drawing
6.1
Dimensional drawing
SCALANCE W774-1/W734-1
Operating Instructions, 07/2013, C79000-G8976-C325-01
35
Technical data
6.1 Dimensional drawing
SCALANCE W774-1/W734-1
36
Operating Instructions, 07/2013, C79000-G8976-C325-01
7
Approvals
CE conformity
The products
SIMATIC NET SCALANCE W774-1 RJ45
SIMATIC NET SCALANCE W734-1 RJ45
in the version put into circulation by Siemens AG conforms to the regulations of the following
European directive:
● 99/5/EC
Directive of the European Parliament and of the Council on radio equipment and
telecommunications terminal equipment and the mutual recognition of their conformity.
Conformity with the basic requirement of the directive is attested by adherence to the
following standards:
● EN 60950-1
Information technology equipment - Safety - Part 1: General requirements
● EN 301489-1 V1.9.2
Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic
compatibility for radio equipment and services - Part 1 : Common technical requirements
(V1.8.1).
● EN 301489-17 V2.2.1
Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic
compatibility for radio equipment and services - Part 17: Specific conditions for 2.4 GHz
broadband transmission systems and 5 GHz high performance RLAN equipment
● EN 300328 V1.7.1
Electromagnetic Compatibility and Radio Spectrum Matters (ERM); — Broadband
transmission systems — Data transmission equipment operating in the 2.4 GHz ISM
band and using spread spectrum modulation techniques — Harmonized EN covering
essential requirements under article 3.2 of the R&TTE Directive
● EN 301893 V1.7.1
Broadband Radio Access Networks (BRAN) - 5 GHz high performance RLAN Harmonized EN covering essential requirements of article 3.2 of the R&TTE Directive
● EN 62311
Assessment of electronic and electrical equipment related to human exposure restrictions
for electro-magnetic fields (0 Hz – 300 GHz)
● 1999/519/EC
Council recommendation on the limitation of exposure of the general public to
electromagnetic fields (0 Hz to 300 GHz)
Devices connected to the system must meet the relevant safety regulations.
The EC Declaration of Conformity is available for the responsible authorities according to the
above-mentioned EC Directive at the following address:
SCALANCE W774-1/W734-1
Operating Instructions, 07/2013, C79000-G8976-C325-01
37
Approvals
Siemens Aktiengesellschaft
Industry Sector
Postfach 4848
D-90026 Nürnberg
This declaration certifies compliance with the directives named above, but does not
guarantee any specific properties.
Note
The specified approvals apply only when the corresponding mark is printed on the product.
Certification ID
The following table shows the product names and the corresponding certification ID:
Type
Certification ID
Order number
Order number US variant
W774-1 RJ-45
MSN-W1-RJ-E2
6GK5774-1FX00-0AA0
6GK5774-1FX00-0AB0
W734-1 RJ-45
MSN-W1-RJ-E2
6GK5734-1FX00-0AA0
6GK5734-1FX00-0AB0
ATEX (explosion protection directive)
WARNING
When using SIMATIC NET products in hazardous area zone 2, make absolutely sure that
the associated conditions in the following document are adhered to:
"Use of subassemblies/modules in a Zone 2 Hazardous Area".
This document can be found on the CD that ships with the device or on the Internet at the
following URL:
http://support.automation.siemens.com/WW/
> Product Support > Industrial Communication
Enter the document identification number A5E00352937 as the search term.
SIMATIC NET products meet the requirements of the EC directive:94/9/EC "Equipment and
Protective Devices for Use in Potentially Explosive Atmospheres".
ATEX classification:
II 3 G Ex nA IIC T4 Gc
SCALANCE W774-1/W734-1
38
Operating Instructions, 07/2013, C79000-G8976-C325-01
Approvals
KEMA 07ATEX0145 X
The products meet the requirements of the following standards:
● EN 60079-15: 2010 (electrical apparatus for potentially explosive atmospheres; Type of
protection "n")
● EN 60079-0: 2009 (Explosive atmospheres - Part 0: Equipment - General requirements)
FM
The product meets the requirements of the standards:
● Factory Mutual Approval Standard Class Number 3611
● FM Hazardous (Classified) Location Electrical Equipment:
Non Incendive / Class I / Division 2 / Groups A,B,C,D / T4 and
Non Incendive / Class I / Zone 2 / Group IIC / T4
cULus Approval Hazardous Location
cULus Listed I. T. E. FOR HAZ. LOC.
Underwriters Laboratories Inc. complying with
● UL 60950-1 (Information Technology Equipment)
● ANSI/ISA 12.12.01-2007
● CSA C22.2 No. 213-M1987
Approved for use in
Cl. 1, Div. 2, GP A, B, C, D T4
Cl. 1, Zone 2, GP IIC T4
Report no. E240480
FCC approval
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause
undesired operation.
___________________________________________________________________________
Notice
Changes or modifications made to this equipment not expressly approved by SIEMENS may
void the FCC authorization to operate this equipment.
___________________________________________________________________________
IEEE 802.11b or g operation of this product in the USA is firmware-limited to channels 1
through 11.
SCALANCE W774-1/W734-1
Operating Instructions, 07/2013, C79000-G8976-C325-01
39
Approvals
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
● Reorient or relocate the receiving antenna.
● Increase the separation between the equipment and receiver.
● Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
● Consult the dealer or an experienced radio/TV technician for help.
___________________________________________________________________________
Notice
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance 20 cm
between the radiator and your body.
___________________________________________________________________________
This transmitter must not be co-located or operating in conjunction with any other antenna or
transmitter. Professional Installation Notice:
To comply with FCC part 15 rules in the United States, the system must be professionally
installed to ensure compliance with the Part 15 certification. It is the responsibility of the
operator and professional installer to ensure that only certified systems are deployed in the
United States. The use of the system in any other combination (such as co-located antennas
transmitting the same information) is expressly forbidden.
CSA Information Technology Equipment
CSA Certification Mark
Canadian Standard Association CSA C22.2 No. 60950-1-03
RSS-210 of Industry Canada
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject
to the following two conditions: (1) this device may not cause interference, and (2) this device must
accept any interference, including interference that may cause undesired operation of the device.
This radio transmitter (IC: 267AA-MSN1V1) has been approved by Industry Canada to
operate with the antenna types listed in section 5.6 with the maximum permissible gain and required
antenna impedance for each antenna type indicated. Antenna types not included in this list,
having a gain greater than the maximum gain indicated for that type, are strictly prohibited
for use with this device.
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may
not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
SCALANCE W774-1/W734-1
40
Operating Instructions, 07/2013, C79000-G8976-C325-01
Approvals
Under Industry Canada regulations, this radio transmitter may only operate using an antenna
of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To
reduce potential radio interference to other users, the antenna type and its gain should be so
chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that
necessary for successful communication.
To reduce potential radio interference to other users, the antenna type and its gain should be
so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that
permitted for successful communication.
That the device for the band 5150-5250 MHz is only for indoor usage to reduce potential for
harmful interference to co-channel mobile satellite systems.
Users should also be cautioned to take note that high power radars are allocated as primary
users (meaning they have priority) of 5250-5350 MHz and 5650-5850 MHz and these radars
could cause interference and/or damage to LE-LAN devices.
This equipment complies with IC RSS-102 radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with minimum
distance 20cm between the radiator & your body.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio
exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil
ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est susceptible d'en compromettre le
fonctionnement.
C-TICK
The product meets the requirements of the AS/NZS 2064 standard (Class A).
Railway approval
The device meets the requirements of the Railway standard EN 50155:2007 "Railway
Applications - Electronic equipment used on rolling stock".
SCALANCE W774-1/W734-1
Operating Instructions, 07/2013, C79000-G8976-C325-01
41
Approvals
7.1 SCALANCE W774/W734 national approvals
7.1
SCALANCE W774/W734 national approvals
National approvals
The following table lists the countries in which the SCALANCE W700 product is approved.
The diamond symbol (♦) identifies all countries for which there was no approval at the time
these operating instructions were written.
The current status of the approvals can be found on the Internet at the following address:
http://www.siemens.com/funkzulassungen
Column
Meaning
Country
Country
Mode
IEEE 802.11 standard and the TPC and / or DFS functionality, where required
CH
Channel
MHz
Frequency
PWR (EIRP)
Maximum permitted effective isotropic radiated power
Use
Permitted use indoors and / or outdoors
SCALANCE W774-1/W734-1
42
Operating Instructions, 07/2013, C79000-G8976-C325-01
Approvals
7.1 SCALANCE W774/W734 national approvals
Country
Mode
CH
Belgium
Bulgaria
Denmark
Germany
Estonia
Finland
France
Greece
Great Britain
Ireland
Iceland
Italy
Croatia
Latvia
Liechtenstein
Lithuania
Luxembourg
Malta
Macedonia
Netherlands
Norway
Austria
Poland
Portugal
Romania
Sweden
Switzerland
Serbia
Slovakia
Slovenia
Spain
Czech Republic
Turkey
Hungary
Cyprus
11g 11n
13
2412
2472
100 mW Indoor + outdoor
11a 11n
5180
5240
200 mW Indoor only
TPC
36
48
52
64
5260
5320
200 mW Indoor only
DFS + TPC
100
116
5500
5580
1000 mW Indoor + outdoor
132
140
5660
5700
1000 mW Indoor + outdoor
11h 11n
MHz
PWR
(EIRP)
Use
SCALANCE W774-1/W734-1
Operating Instructions, 07/2013, C79000-G8976-C325-01
43
Approvals
7.1 SCALANCE W774/W734 national approvals
Country
Mode
Australia
11g 11n
CH
MHz
11a 11n
TPC
11h 11n
DFS + TPC
11a 11n
TPC
Brazil
11g 11n
11a 11n
TPC
11a 11n
TPC
11g 11n
36
5180
5240
52
5260
64
5320
5745
5825
2412
13
2472
36
5180
TPC
5320
100
5500
5700
149
5745
200 mW Indoor only
1000 mW Indoor + outdoor
4000 mW Indoor + outdoor
165
5825
2412
100 mW Indoor + outdoor
13
2472
149
5745
165
4000 mW Indoor + outdoor
140
400 mW Indoor + outdoor
64
200 mW Indoor only
165
200 mW Indoor only
149
100 mW Indoor + outdoor
48
Use
2472
11a 11n
2412
13
China
PWR
(EIRP)
2000 mW Indoor + outdoor
5825
SCALANCE W774-1/W734-1
44
Operating Instructions, 07/2013, C79000-G8976-C325-01
Approvals
7.1 SCALANCE W774/W734 national approvals
Country
Mode
Japan
11g 11n
CH
MHz
11a
TPC
11a 11n
DFS + TPC
5040
12
5060
16
5080
36
5180
TPC
5240
52
5260
200 mW Indoor + outdoor
200 mW Indoor only
200 mW Indoor only
64
5320
100
5500
200 mW Indoor + outdoor
140
5700
184
4920
200 mW Indoor + outdoor
48
Use
2472
11a
2412
13
11h 11n
PWR
(EIRP)
200 mW Indoor + outdoor
196
4980
2412
100 mW Indoor + outdoor
Peru
2417
200 mW Indoor + outdoor
Puerto Rico
Canada
11g 11n
USA
11a 11n
TPC
10
2457
11
2462
100 mW Indoor + outdoor
36
5180
200 mW Indoor only
48
5240
149
5745
165
400 mW Indoor + outdoor
5825
SCALANCE W774-1/W734-1
Operating Instructions, 07/2013, C79000-G8976-C325-01
45
Approvals
7.1 SCALANCE W774/W734 national approvals
SCALANCE W774-1/W734-1
46
Operating Instructions, 07/2013, C79000-G8976-C325-01

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : Siemens AG
Create Date                     : 2013:07:05 13:41:49+02:00
Keywords                        : C79000-G8976-C325-01;, 07/2013
Modify Date                     : 2014:04:02 16:42:50+02:00
Subject                         : Operating Instructions
Has XFA                         : No
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Metadata Date                   : 2014:04:02 16:42:50+02:00
Creator Tool                    : Acrobat PDFMaker 10.1 für Word
Document ID                     : uuid:80d45d8e-aad6-46fb-a753-f6035cf23f70
Instance ID                     : uuid:b93ddac8-2b9c-4fea-8ed4-3f7868a69fcf
Format                          : application/pdf
Title                           : SCALANCE W774-1/W734-1
Description                     : Operating Instructions
Creator                         : Siemens AG
Producer                        : Adobe PDF Library 10.0
Source Modified                 : D:20130705114103
Company                         : Siemens AG
Comments                        : 
Edition                         : 0.00347739692001987
System                          : SIMATIC NET
Print-year                      : 2013
Document-class                  : Operating Instructions
Document-class-mrl              : 
Product-group                   : Industrial Wireless LAN
Order-nr                        : C79000-G8976-C325-01
Ident-nr                        : 
Company-short                   : Siemens
Company-long                    : Siemens AG
Headline                        : Operating Instructions
Page Layout                     : OneColumn
Page Count                      : 46
EXIF Metadata provided by EXIF.tools
FCC ID Filing: LYHMSN1V1

Navigation menu