Siemens MSN65V1 Industrial Wireless LAN access point User Manual

Siemens AG Industrial Wireless LAN access point Users Manual

Contents

Users Manual

Download: Siemens MSN65V1 Industrial Wireless LAN access point User Manual
Mirror Download [FCC.gov]Siemens MSN65V1 Industrial Wireless LAN access point User Manual
Document ID3567759
Application IDyVsj/XTp91BRQdzKTi1ZJg==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize59.78kB (747220 bits)
Date Submitted2017-09-19 00:00:00
Date Available2017-09-27 00:00:00
Creation Date2017-09-06 16:36:00
Producing SoftwarePDF-XChange Printer 2012 (5.5 build 315) [Windows 7 Enterprise x64 (Build 7601: Service Pack 1)]
Document Lastmod0000-00-00 00:00:00
Document TitleUsers Manual

W780 / W740 802.11n
W788C / W786C 802.11n
SIMATIC NET
W770/W730 802.11n
Industrial Wireless LAN
Approvals SCALANCE W700
802.11n
W760/W720 802.11n
Reference Manual
01/2017
C79000-G8976-C392-05
Legal information
Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent
damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert
symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are
graded according to the degree of danger.
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
indicates that minor personal injury can result if proper precautions are not taken.
NOTICE
indicates that property damage can result if proper precautions are not taken.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will
be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to
property damage.
Qualified Personnel
The product/system described in this documentation may be operated only by personnel qualified for the specific
task in accordance with the relevant documentation, in particular its warning notices and safety instructions.
Qualified personnel are those who, based on their training and experience, are capable of identifying risks and
avoiding potential hazards when working with these products/systems.
Proper use of Siemens products
Note the following:
Trademarks
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical
documentation. If products and components from other manufacturers are used, these must be recommended
or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and
maintenance are required to ensure that the products operate safely and without any problems. The permissible
ambient conditions must be complied with. The information in the relevant documentation must be observed.
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication
may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software
described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the
information in this publication is reviewed regularly and any necessary corrections are included in subsequent
editions.
Siemens AG
Division Process Industries and Drives
Postfach 48 48
90026 NÜRNBERG
GERMANY
C79000-G8976-C392-05
Ⓟ 01/2017 Subject to change
Copyright © Siemens AG 2014 - 2017.
All rights reserved
Table of contents
Approvals for SCALANCE W780 / W740 802.11n ................................................................................. 5
1.1
1.1.1
1.1.2
1.1.3
1.1.3.1
1.1.3.2
1.1.3.3
1.1.4
EC declaration of conformity ................................................................................................ 7
ATEX .................................................................................................................................. 8
RoHS .................................................................................................................................. 8
R&TTE / RED...................................................................................................................... 8
Protection of health and safety ............................................................................................ 8
EMC.................................................................................................................................... 9
Efficient use of the radio spectrum ....................................................................................... 9
Products............................................................................................................................ 10
1.2
General approvals ............................................................................................................. 12
1.3
National approvals............................................................................................................. 21
Approvals for SCALANCE W788C / W786C 802.11n ...........................................................................39
2.1
2.1.1
2.1.2
2.1.3
2.1.3.1
2.1.3.2
2.1.3.3
2.1.4
EC declaration of conformity .............................................................................................. 40
ATEX ................................................................................................................................ 41
RoHS ................................................................................................................................ 41
R&TTE / RED.................................................................................................................... 41
Protection of health and safety .......................................................................................... 41
Efficient use of the radio spectrum ..................................................................................... 42
EMC.................................................................................................................................. 42
Products............................................................................................................................ 43
2.2
General approvals ............................................................................................................. 44
2.3
National approvals............................................................................................................. 52
Approvals for SCALANCE W770/W730 802.11n..................................................................................69
3.1
3.1.1
3.1.2
3.1.3
3.1.3.1
3.1.3.2
3.1.3.3
3.1.4
EC declaration of conformity .............................................................................................. 70
ATEX ................................................................................................................................ 71
RoHS ................................................................................................................................ 71
R&TTE / RED.................................................................................................................... 71
Protection of health and safety .......................................................................................... 71
EMC.................................................................................................................................. 72
Efficient use of the radio spectrum ..................................................................................... 72
Products W770/W730 ....................................................................................................... 73
3.2
General approvals ............................................................................................................. 74
3.3
SCALANCE W774/734 national approvals......................................................................... 80
3.4
SCALANCE W778/738 national approvals......................................................................... 95
Approvals for SCALANCE W760/W720 802.11n............................................................................... 103
4.1
4.1.1
4.1.2
4.1.3
EC declaration of conformity ............................................................................................ 104
ATEX .............................................................................................................................. 105
RoHS .............................................................................................................................. 105
R&TTE / RED.................................................................................................................. 105
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
Table of contents
4.1.3.1
4.1.3.2
4.1.3.3
4.1.4
Protection of health and safety ........................................................................................ 105
EMC ............................................................................................................................... 106
Efficient use of the radio spectrum ................................................................................... 106
Products...........................................................................................................................107
4.2
General approvals ............................................................................................................108
4.3
National approvals............................................................................................................114
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
Approvals for SCALANCE W780 / W740 802.11n
Note
Issued approvals on the type plate of the device
The specified approvals apply only when the corresponding mark is printed on the product.
You can check which of the following approvals have been granted for your product by the
markings on the type plate.
Range of validity
The approvals listed in this section apply to the following products:
Article number of the
RoW version:
Article number of the
US version:
Article number of the
Israel version:
6GK5 786-1FC00-0AA0
6GK5 786-1FC00-0AB0
SCALANCE W786-2 RJ-45
6GK5 786-2FC00-0AA0
6GK5 786-2FC00-0AB0
6GK5786-2FC00-0AC0
SCALANCE W786-2IA RJ-45
6GK5 786-2HC00-0AA0
6GK5 786-2HC00-0AB0
SCALANCE W786-2 SFP
6GK5 786-2FE00-0AA0
6GK5 786-2FE00-0AB0
Article number of the
RoW version:
Article number of the
US version:
Article number of the
Israel version:
SCALANCE W788-1 RJ-45
6GK5788-1FC00-0AA0
6GK5788-1FC00-0AB0
SCALANCE W788-1 M12
6GK5788-1GD00-0AA0
6GK5788-1GD00-0AB0
6GK5788-2FC00-0AA0
6GK5788-2FC00-0AB0
6GK5788-2FC00-0AC0
SCALANCE W788-2 M12
6GK5788-2GD00-0AA0
6GK5788-2GD00-0AB0
SCALANCE W788-2 M12 EEC
6GK5788-2GD00-0TA0
6GK5788-2GD00-0TB0
SCALANCE W748-1 RJ-45
6GK5748-1FC00-0AA0
6GK5748-1FC00-0AB0
SCALANCE W748-1 M12
6GK5748-1GD00-0AA0
6GK5748-1GD00-0AB0
Access point
SCALANCE W786-1 RJ-45
Dual access points
Access points
Dual access points
SCALANCE W788-2 RJ-45
Ethernet client modules
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
ApprovalsforSCALANCEW780/W740802.11n
1.1 EC declaration of conformity
Abbreviations used
Some approvals apply only to certain devices or series. In such situations, the designations
of the products are shortened to avoid having to list all the type designations. The following
table shows how the abbreviations relate to the product variants.
Product group
The designation . . .
stands for . . .
Product name
Access points (IP30 and IP65)
W788-x
SCALANCE W788-1 M12
SCALANCE W788-2 M12
SCALANCE W788-2 M12 EEC
SCALANCE W788-1 RJ-45
SCALANCE W788-2 RJ-45
Access points (IP65)
W786-x
SCALANCE W786-1 RJ-45
SCALANCE W786-2 RJ-45
SCALANCE W786-2IA RJ-45
SCALANCE W786-2 SFP
SCALANCE W without W786-x
W7x8
SCALANCE W788-1 RJ-45
SCALANCE W788-1 M12
SCALANCE W788-2 RJ-45
SCALANCE W788-2 M12
SCALANCE W788-2 M12 EEC
SCALANCE W748-1 RJ-45
SCALANCE W748-1 M12
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
ApprovalsforSCALANCEW780/W740802.11n
1.1 EC declaration of conformity
1.1
EC declaration of conformity
The EC Declaration of Conformity is available for all responsible authorities at:
Siemens Aktiengesellschaft
Process Industries and Drives Division,
Process Automation
DE-76181 Karlsruhe
Germany
You will find the current EC declaration of conformity for these products on the Internet
pages of Siemens Industry Online Support
(hhttps://support.industry.siemens.com/cs/ww/en/ps/15853/cert).
The SIMATIC NET products described in these Operating Instructions meet the
requirements of the following EC directives:
● 94/9/EC
Directive of the European Parliament and the Council of 23 March 1994 on the
approximation of the laws of the Member States concerning equipment and protective
systems intended for use in potentially explosive atmospheres (until 19.04.2016).
● 2014/34/EU
Directive 2014/34/EU of the European Parliament and of the Council of 26 February 2014
on the harmonization of the laws of the Member States relating to equipment and
protective systems intended for use in potentially explosive atmospheres official journal of
the EU L96, 29/03/2014, pages. 309–356 (as of 20.04.2016)
● 1999/5/EC
Directive of the European Parliament and of the Council of 1999 March 1999 on Radio
Equipment and Telecommunications Terminal Equipment and the mutual recognition of
their conformity (until 12.06.2016).
● 2014/53/EU
Directive of the European Parliament and of the Council of April 16, 2014 on the
harmonization of the laws of the member states relating to placing radio equipment on the
market.; official journal of the EU L153, 22/05/2014, pages. 62–106 (as of 13.06.2016)
● 2011/65/EU (RoHS)
RoHS directive of the European Parliament and of the Council of 8 June 2011 on the
restriction of the use of certain hazardous substances in electrical and electronic
equipment.
● 1999/519/EC
Council recommendation on the limitation of exposure of the general public to
electromagnetic fields (0 Hz to 300 GHz)
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
ApprovalsforSCALANCEW780/W740802.11n
1.1 EC declaration of conformity
1.1.1
ATEX
ATEX directive (correct usage in potentially explosive atmospheres)
The SIMATIC NET product meets the requirements of the EC directive:94/9/EC (until
19.04.2016) and 2014/34/EU (as of 20.04.2016) "Equipment and Protective Devices for Use
in Potentially Explosive Atmospheres" according to the standards listed in the section
Products (Page 10):
Applied standard:
EN 60079-0 + A11
Hazardous areas - Part 0: Equipment - General requirements
EN 60079-15
Explosive atmospheres - Part 15: Equipment protection by type of protection "n"
1.1.2
RoHS
RoHS directive (restriction of the use of certain hazardous substances)
The SIMATIC NET products described in these operating instructions meet the requirements
of the EC directive 2011/65/EC for the restriction of the use of certain hazardous substances
in electrical and electronic equipment:
Applied standard:
EN 50581
Technical documentation for the assessment electrical and electronic products with
respect to restriction of hazardous substances
1.1.3
R&TTE / RED
1.1.3.1
Protection of health and safety
Article 3 (1) a) protection of health and safety
EN 60950-1+A1+A2+A11+A12
Information technology equipment - Safety - Part 1: General requirements
EN 62311
Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz – 300 GHz)
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
ApprovalsforSCALANCEW780/W740802.11n
1.1 EC declaration of conformity
1.1.3.2
EMC
Art. 3 (1) b - EMC
EN 50121-3-2+AC
Railway applications - Electromagnetic compatibility - part 3-2: Railway Vehicles Devices
EN 50121-4+AC
Railway applications - Electromagnetic compatibility - part 4: Interference emissions
and immunity of signal telecommunications equipment
ETSI EN 301 489-1
Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic
compatibility for radio equipment and services - Part 1 : Common technical requirements
ETSI EN 301 489-17
10
11
12
13
1.1.3.3
Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic
compatibility for radio equipment and services - Part 17 :
EN 61000-6-1
Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for
residential, commercial and light-industrial environments
EN 61000-6-2+AC
Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for
industrial environments
EN 61000-6-3+A1+AC
Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission
standard for residential, commercial and light-industrial environments
EN 61000-6-4+A1
Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission
standard for industrial environments
Efficient use of the radio spectrum
Art. 3 (2) Efficient use of the radio spectrum
14
ETSI EN 301 328
Electromagnetic compatibility and radio spectrum matters (ERM) - wideband
transmission systems - data transmission equipment operating in the 2.4 GHz ISM
band and using wideband modulation techniques. Harmonized EN containing the
essential requirements according to Article 3.2 of the R&TTE directive.
15
ETSI EN 301 893
Broadband Radio Access Networks (BRAN) - 5 GHz high performance RLAN Harmonized EN covering essential requirements of article 3.2 of the R&TTE Directive
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
ApprovalsforSCALANCEW780/W740802.11n
1.1 EC declaration of conformity
1.1.4
Products
Product designation and standards
The standards that apply to the product are described in RoHS (Page 8), ATEX (Page 8) and
R&TTE / RED (Page 8).
Product name
Standards
W786-1 RJ45
1, 2 3, 4, 5, 8, 9, 10, 11, 12, 13, 14, 15,
W786-2 RJ45
W786-2IA RJ45
W786-2 SFP
W788-1 RJ45
W788-2 RJ45
W788-1 M12
W788-2 M12
W748-1 RJ45
W748-1 M12
W788-2 M12 EEC
1, 2 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15
Approvals SCALANCE W700 802.11n
10
Reference Manual, 01/2017, C79000-G8976-C392-05
ApprovalsforSCALANCEW780/W740802.11n
1.1 EC declaration of conformity
Certification ID
The following tables show the product names and the corresponding certification ID:
Type
Number and type of
Number of interthe Ethernet interfaces nal antennas
Number of R-SMA
sockets for external
antennas
W786-1 RJ-45
1 x RJ-45
EAPN-W1-RJ-E3
6GK5 786-1FC00-0AA0
6GK5 786-1FC00-0AB0
W786-2 RJ-45
1 x RJ-45
EAPN-W2-RJ-E3
6GK5 786-2FC00-0AA0
6GK5 786-2FC00-0AB0
W786-2IA RJ-45
1 x RJ-45
EAPN-W2-RJ-I3
6GK5 786-2HC00-0AA0
6GK5 786-2HC00-0AB0
W786-2 SFP
2 x SFP
EAPN-W2-SFP-E3
6GK5 786-2FE00-0AA0
Certification ID
Article number
Article number US variant
6GK5 786-2FE00-0AB0
Type
Certification ID
Article number:
Article number US variant
W788-1 RJ-45
RAPN-W1-RJ-E3
6GK 5788-1FC00-0AA0
6GK 5788-1FC00-0AB0
W788-2 RJ-45
RAPN-W2-RJ-E3
6GK5 788-2FC00-0AA0
6GK5 788-2FC00-0AB0
W788-1 M12
RAPN-W1-M12-E3
6GK5 788-1GD00-0AA0
6GK5 788-1GD00-0AB0
W788-2 M12
RAPN-W2-M12-E3
6GK5 788-2GD00-0AA0
6GK5 788-2GD00-0AB0
W788-2 M12 EEC
RAPN-W2-M12-E3
6GK5 788-2GD00-0TA0
6GK5 788-2GD00-0TB0
W748-1 RJ-45
RAPN-W1-RJ-E3
6GK5 748-1FC00-0AA0
6GK5 748-1FC00-0AB0
W748-1 M12
RAPN-W1-M12-E3
6GK5 748-1GD00-0AA0
6GK5 748-1GD00-0AB0
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
11
ApprovalsforSCALANCEW780/W740802.11n
1.2 General approvals
1.2
General approvals
ATEX (explosion protection directive)
WARNING
When using SIMATIC NET products in hazardous area zone 2, make absolutely sure that
the associated conditions in the following document are adhered to:
"SIMATIC NET Product Information Use of subasseblies/modules in a Zone 2 Hazardous
Area".
You will find this document
on the data medium that ships with some devices.
on the Internet pages of Siemens Industry Online Support
(http://support.automation.siemens.com/ww).
Enter the document identification number C234 as the search term.
The SIMATIC NET products meet the requirements of the EC directive 94/9/EC "Equipment
and Protective Devices for Use in Potentially Explosive Atmospheres”. and as of 20.04.2016
the EC directive 2014/34/EU.
ATEX classification:
II 3 G Ex nA IIC T4 Gc
KEMA 07ATEX0145 X
The products meet the requirements of the following standards:
● EN 60079-15 (electrical apparatus for potentially explosive atmospheres; Type of
protection "n")
● EN 60079-0 (Explosive atmospheres - Part 0: Equipment - General requirements)
You will find the current versions of the standards in the currently valid ATEX certificates.
IECEx
The SIMATIC NET products meet the requirements of explosion protection according to
IECEx.
IECEx classification:
Ex nA IIC T4 Gc
DEK 14.0025X
The products meet the requirements of the following standards:
● IEC 60079-15 (Explosive atmospheres - Part 15: Equipment protection by type of
protection "n")
● IEC 60079-0 (Explosive atmospheres - Part 0: Equipment - General requirements)
You will find the current versions of the standards in the currently valid IECEx certificates.
Approvals SCALANCE W700 802.11n
12
Reference Manual, 01/2017, C79000-G8976-C392-05
ApprovalsforSCALANCEW780/W740802.11n
1.2 General approvals
FM
The product meets the requirements of the standards:
● Factory Mutual Approval Standard Class Number 3611
● FM Hazardous (Classified) Location Electrical Equipment:
Non Incendive / Class I / Division 2 / Groups A,B,C,D / T4 and
Non Incendive / Class I / Zone 2 / Group IIC / T4
cULus Approval for Information Technology Equipment
cULus Listed I. T. E.
Underwriters Laboratories Inc. complying with
● UL 60950-1 (Information Technology Equipment)
● CSA C22.2 No. 60950-1-03
Report no. E115352
Note
Only devices of the SCALANCE W786-x series have this approval.
cULus Approval Hazardous Location
cULus Listed I. T. E. FOR HAZ. LOC.
Underwriters Laboratories Inc. complying with
● UL 60950-1 (Information Technology Equipment)
● ANSI/ISA 12.12.01-2007
● CSA C22.2 No. 213-M1987
Approved for use in
Cl. 1, Div. 2, GP A, B, C, D T4
Cl. 1, Zone 2, GP IIC T4
Report no. E240480
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
13
ApprovalsforSCALANCEW780/W740802.11n
1.2 General approvals
FCC approval
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause
undesired operation.
Notice
Changes or modifications made to this equipment not expressly approved by SIEMENS may
void the FCC authorization to operate this equipment.
IEEE 802.11b or g operation of this product in the USA is firmware-limited to channels 1
through 11.
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
● Reorient or relocate the receiving antenna.
● Increase the separation between the equipment and receiver.
● Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
● Consult the dealer or an experienced radio/TV technician for help.
Notice
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance 20 cm
between the radiator and your body.
This transmitter must not be co-located or operating in conjunction with any other antenna or
transmitter. Professional Installation Notice:
To comply with FCC part 15 rules in the United States, the system must be professionally
installed to ensure compliance with the Part 15 certification. It is the responsibility of the
operator and professional installer to ensure that only certified systems are deployed in the
United States. The use of the system in any other combination (such as co-located antennas
transmitting the same information) is expressly forbidden.
Approvals SCALANCE W700 802.11n
14
Reference Manual, 01/2017, C79000-G8976-C392-05
ApprovalsforSCALANCEW780/W740802.11n
1.2 General approvals
Notice
For use of DFS channels
● Use of the RCoax Cable Antenna 6XV1875-2D is not permitted in channels which
require dynamic frequency selection (DFS).
● Any installation of either a master or a client device within 35 km of a TDWR (Terminal
Doppler Weather Radar) location shall be separated by at least 30 MHz (center-to-center)
from the TDWR operating frequency.
These devices shall be registered in the industry sponsored WISPA database,
http://udia.spectrumbridge.com/udia/home.aspx
(http://udia.spectrumbridge.com/udia/home.aspx)
When you open this link, you get the following choices:
– "Search" opens a window with TDWR locations and frequencies.
– "User Signup" allows you to register as user of the database.
– After registering you can Logon and register your WLAN location. Please fill in all
required information.
For more information with respect to WISPA database and TWDR locations please consult
FCC publication KDB 443999 D01.
NEMA TS2
The product meets the requirements of the standard
NEMA TS2 (Traffic Controller Assemblies with NTCIP Requirements)
SCALANCE W788-2 M12 EEC
6GK5788-2GD00-0TA0
6GK5788-2GD00-0TB0
RSS-247 of Industry Canada for SCALANCE W786-x
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) this device may not cause
interference, and (2) this device must accept any interference, including interference that
may cause undesired operation of the device.
This radio transmitter (IC: 267AA-MPCIE1V1) has been approved by Industry Canada to
operate with the antenna types listed in section 6.8 with the maximum permissible gain and
required antenna impedance for each antenna type indicated. Antenna types not included in
this list, having a gain greater than the maximum gain indicated for that type, are strictly
prohibited for use with this device.
Under Industry Canada regulations, this radio transmitter may only operate using an antenna
of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To
reduce potential radio interference to other users, the antenna type and its gain should be so
chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that
necessary for successful communication.
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
15
ApprovalsforSCALANCEW780/W740802.11n
1.2 General approvals
To reduce potential radio interference to other users, the antenna type and its gain should be
so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that
permitted for successful communication.
That the device for the band 5150-5250 MHz is only for indoor usage to reduce potential for
harmful interference to co-channel mobile satellite systems.
Users should also be cautioned to take note that high power radars are allocated as primary
users (meaning they have priority) of 5250-5350 MHz and 5650-5850 MHz and these radars
could cause interference and/or damage to LE-LAN devices.
This equipment complies with IC RSS-102 radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with minimum
distance 20cm between the radiator & your body.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils
radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1)
l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout
brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le
fonctionnement.
RSS-247 of Industry Canada for SCALANCE W7x8
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) this device may not cause
interference, and (2) this device must accept any interference, including interference that
may cause undesired operation of the device.
This radio transmitter (IC: 267AA-MPCIE1V1) has been approved by Industry Canada to
operate with the antenna types listed in section 5.4 with the maximum permissible gain and
required antenna impedance for each antenna type indicated. Antenna types not included in
this list, having a gain greater than the maximum gain indicated for that type, are strictly
prohibited for use with this device.
Under Industry Canada regulations, this radio transmitter may only operate using an antenna
of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To
reduce potential radio interference to other users, the antenna type and its gain should be so
chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that
necessary for successful communication.
To reduce potential radio interference to other users, the antenna type and its gain should be
so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that
permitted for successful communication.
That the device for the band 5150-5250 MHz is only for indoor usage to reduce potential for
harmful interference to co-channel mobile satellite systems.
Users should also be cautioned to take note that high power radars are allocated as primary
users (meaning they have priority) of 5250-5350 MHz and 5650-5850 MHz and these radars
could cause interference and/or damage to LE-LAN devices.
This equipment complies with IC RSS-102 radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with minimum
distance 20cm between the radiator & your body.
Approvals SCALANCE W700 802.11n
16
Reference Manual, 01/2017, C79000-G8976-C392-05
ApprovalsforSCALANCEW780/W740802.11n
1.2 General approvals
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils
radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1)
l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout
brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le
fonctionnement.
Note for USA, Canada, Puerto Rico, Peru, Bahamas, Ecuador and Columbia
When operating the SCALANCE W700 with DFS (Dynamic Frequence Selection), the
IWLAN RCoax Cable 5 GHz (order number 6XV1875-2D) may not be used in the countries
listed above.
Approvals in Argentina
Devices of the SCALANCE W786-x series are approved in Argentina under the following
certification numbers:
Certification ID
Certification number
EAPN-W1-RJ-E3
CNC: C-11549
EAPN-W2-RJ-E3
CNC: C-11536
EAPN-W2-RJ-I3
CNC: C-11564
EAPN-W2-SFP-E3
CNC: C-11547
Devices of the SCALANCE W788-x series are approved in Argentina under the following
certification numbers:
Certification ID
Certification number
RAPN-W1-RJ-E3
CNC: C-11541
RAPN-W2-RJ-E3
CNC: C-11502
RAPN-W1-M12-E3
CNC: C-11546
RAPN-W2-M12-E3
CNC: C-11548
Approval in Brazil
From the SCALANCE W786-x series, the following devices are approved for Brazil:
Type
Order number
EAPN number
W786-1 RJ-45
6GK5 786-1FC00-0AA0
EAPN-W1-RJ-E3
W786-2 RJ-45
6GK5 786-2FC00-0AA0
EAPN-W2-RJ-E3
W786C-2 RJ-45
6GK5 786-2FC00-1AA0
EAPN-W2-RJ-E3
W786-2IA RJ-45
6GK5 786-2HC00-0AA0
EAPN-W2-RJ-I3
W786C-2IA RJ-45
6GK5 786-2HC00-1AA0
EAPN-W2-RJ-I3
W786-2 SFP
6GK5 786-2FE00-0AA0
EAPN-W2-SFP-E3
The listed devices are approved in Brazil under the following certification numbers:
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
17
ApprovalsforSCALANCEW780/W740802.11n
1.2 General approvals
Este equipamento opera em caráter secundário, isto, ist é, não tem direito à proteção contra
interferência prejudicial, mesmo de estações do mesmo tipo e não pode causar interferência
a sistemas operando em caráter primário.
From the SCALANCE W7x8 series, the following devices are approved for Brazil:
Type
Order number
RAPN number
W788-1 RJ-45
6GK 5788-1FC00-0AA0
RAPN-W1-RJ-E3
W788-2 RJ-45
6GK5 788-2FC00-0AA0
RAPN-W2-RJ-E3
W788-1 M12
6GK5 788-1GD00-0AA0
RAPN-W1-M12-E3
W788-2 M12
6GK5 788-2GD00-0AA0
RAPN-W2-M12-E3
W788-2 M12 EEC
6GK5 788-2GD00-0TA0
RAPN-W2-M12-E3
W748-1 RJ-45
6GK5 748-1FC00-0AA0
RAPN-W1-RJ-E3
W748-1 M12
6GK5 748-1GD00-0AA0
RAPN-W1-M12-E3
W788C-2 RJ-45
6GK 5788-2FC00-1AA0
RAPN-W2-RJ-E3
W788C-2 M12
6GK5 788-2GD00-1AA0
RAPN-W2-M12-E3
W788C-2 M12 EEC
6GK5788-2GD00-1TA0
RAPN-W2-M12-E3
The listed devices are approved in Brazil under the following certification numbers:
Este equipamento opera em caráter secundário, isto, ist é, não tem direito à proteção contra
interferência prejudicial, mesmo de estações do mesmo tipo e não pode causar interferência
a sistemas operando em caráter primário.
Approvals SCALANCE W700 802.11n
18
Reference Manual, 01/2017, C79000-G8976-C392-05
ApprovalsforSCALANCEW780/W740802.11n
1.2 General approvals
KCC Statement (Republic of Korea)
사용자안내문(제5조제1항제1호관련)
기종별
A 급 기기급 기기
(업무용 방송통신기기)
사용자안내문
이 기기는 업무용(A 급)으로 전자파적합등록을 한(A 급)으로
전자파적합등록을 한
기기이오니 판매자 또는 사용자는 이 점을
주의하시기 바라며, 가정외의 지역에서 사용하는
것을 목적으로 합니다.
"당해 무선설비는 전파혼신 가능성이 있으므로 인명안전과 관련된 서비스는 할 수 없음"
Approval for Mexico
The WLAN modules included in the devices have the following certification number:
RCPSIMP12-0751
Approval for Oman
Devices of the SCALANCE W786-x series are approved in Oman under the following
certification numbers:
OMAN-TRA
R/1773/14
D090258
Devices of the SCALANCE W788-x series are approved in Oman under the following
certification numbers:
OMAN-TRA
R/1772/14
D090258
NCC Warning Statement (Taiwan)
Article 12
Without permission, any company, firm or user shall not alter the frequency, increase the
power, or change the characteristics and functions of the original design of the certified lower
power frequency electric machinery.
Article 14
The application of low power frequency electric machineries shall not affect the navigation
safety nor interfere a legal communication, if an interference is found, the service will be
suspended until improvement is made and the interference no longer exists.
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
19
ApprovalsforSCALANCEW780/W740802.11n
1.2 General approvals
Marking for the customs union
EAC (Eurasian Conformity)
Customs union of Russia, Belarus and Kazakhstan
Declaration of the conformity according to the technical regulations of the customs union
(TR CU)
Approvals SCALANCE W700 802.11n
20
Reference Manual, 01/2017, C79000-G8976-C392-05
ApprovalsforSCALANCEW780/W740802.11n
1.3 National approvals
1.3
National approvals
The following table lists the countries in which the SCALANCE W700 product is approved.
The diamond symbol (♦) identifies all countries for which there was no approval at the time
these operating instructions were written.
The current status of the approvals can be found on the Internet at the following address:
http://www.siemens.com/funkzulassungen
Column
Meaning
Country
Country
Mode
IEEE 802.11 standard and the TPC and / or DFS functionality, where required
CH
Channel
MHz
Frequency
PWR (EIRP)
Maximum permitted effective isotropic radiated power
Use
Permitted use indoors and / or outdoors
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
21
ApprovalsforSCALANCEW780/W740802.11n
1.3 National approvals
Country
Mode
Andorra
Belgium
Bosnia and Herzegovina
Bulgaria
Denmark
Germany
Estonia
Finland
France
Greece
Great Britain
Ireland
Iceland
Italy
Croatia
Latvia
Liechtenstein
Lithuania
Luxembourg
Malta
Macedonia
Monaco
Montenegro
Netherlands
Norway
Austria
Poland
Portugal
Romania
San Marino
Sweden
Switzerland
Slovakia
Slovenia
Spain
Czech Republic
Turkey
Hungary
Vatican
Cyprus
11g 11n
CH
MHz
PWR
(EIRP)
Use
13
2412
2472
100 mW Indoor + outdoor
36
48
5180
5240
200 mW Indoor only
TPC
52
64
5260
5320
200 mW Indoor only
DFS + TPC
100
116
5500
5580
1000 mW Indoor + outdoor
132
140
5660
5700
1000 mW Indoor + outdoor
149
165
5745
5825
25 mW Indoor + outdoor
11a 11n
11a 11n
11a 11n
Approvals SCALANCE W700 802.11n
22
Reference Manual, 01/2017, C79000-G8976-C392-05
ApprovalsforSCALANCEW780/W740802.11n
1.3 National approvals
Country
Mode
Egypt
11g 11n
CH
11a 11n
TPC
Angola
11g 11n
11a 11n
TPC
11a 11n
DFS + TPC
MHz
2412
13
2472
36
5180
5320
2412
13
2472
36
5180
48
5240
5260
11g 11n
11a 11n
5320
100
5500
11a 11n
TPC
5580
132
5660
5700
2412
13
2472
36
5180
48
5240
5260
11a 11n
5320
100
5500
5600
132
5660
1000 mW Indoor + outdoor
50 mW Indoor + outdoor
250 mW Indoor + outdoor
250 mW Indoor + outdoor
250 mW Indoor + outdoor
140
5700
149
5745
1000 mW Indoor + outdoor
120
165
1000 mW Indoor + outdoor
64
200 mW Indoor only
52
200 mW Indoor only
140
100 mW Indoor + outdoor
116
200 mW Indoor only
64
100 mW Indoor + outdoor
52
Use
64
Argentina
PWR
(EIRP)
1000 mW Indoor + outdoor
5825
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
23
ApprovalsforSCALANCEW780/W740802.11n
1.3 National approvals
Country
Mode
Australia
11g 11n
CH
New Zealand
11a 11n
MHz
2412
13
2472
36
5180
11a 11n
DFS + TPC
11a 11n
5240
52
5260
11g 11n
11a 11n
5320
149
5745
11a 11n
DFS + TPC
5825
2412
11a 11n
2472
36
5180
Belarus
11g 11n
11a 11n
TCP
5240
52
5260
11a 11n
TCP + DFS
5320
149
5745
5825
2412
13
2472
36
5180
5240
52
5260
2000 mW Indoor + outdoor
100 mW Indoor + outdoor
100 mW Indoor + outdoor
100 mW Indoor + outdoor
64
5320
132
5660
140
200 mW Indoor only
48
200 mW Indoor only
165
100 mW Indoor + outdoor
64
400 mW Indoor + outdoor
48
200 mW Indoor only
13
200 mW Indoor only
165
100 mW Indoor + outdoor
64
Use
48
Bahrain
PWR
(EIRP)
100 mW Indoor + outdoor
5700
Approvals SCALANCE W700 802.11n
24
Reference Manual, 01/2017, C79000-G8976-C392-05
ApprovalsforSCALANCEW780/W740802.11n
1.3 National approvals
Country
Mode
Brazil
11g 11n
CH
11a 11n
MHz
2412
13
2472
36
5180
11a 11n
TPC
5240
52
5260
Chile
11g 11n
11a 11n
TPC
5320
100
5500
11a 11n
DFS + TPC
5700
149
5745
11a 11n
DFS
China
11g 11n
5825
2412
13
2472
36
5180
5240
52
5260
11a 11n
TPC
5320
149
5745
11a 11n
DFS + TPC
5825
2412
11a 11n
2472
36
5180
Ivory Coast
11g 11n
5240
52
5260
100 mW Indoor only
100 mW Indoor + outdoor
200 mW Indoor only
200 mW Indoor only
64
5320
149
5745
2000 mW Indoor + outdoor
165
5825
2412
13
100 mW Indoor only
48
100 mW Indoor only
13
100 mW Indoor only
165
4000 mW Indoor + outdoor
64
1000 mW Indoor + outdoor
48
200 mW Indoor only
165
200 mW Indoor only
140
4000 mW Indoor + outdoor
64
Use
48
11a 11n
PWR
(EIRP)
100 mW Indoor + outdoor
2472
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
25
ApprovalsforSCALANCEW780/W740802.11n
1.3 National approvals
Country
Mode
CH
11a 11n
MHz
36
TPC
11a 11n
DFS + TPC
5240
5260
11a 11n
DFS + TPC
5320
100
5500
200 mW Indoor only
1000 mW Indoor + outdoor
116
5580
132
5660
1000 mW Indoor + outdoor
140
5700
2412
100 mW Indoor + outdoor
2417
200 mW Indoor + outdoor
10
2457
11
2462
100 mW Indoor + outdoor
36
5180
200 mW Indoor only
48
5240
52
5260
64
5320
5500
400 mW Indoor + outdoor
116
5580
132
5660
400 mW Indoor + outdoor
100
Hong Kong
200 mW Indoor only
64
11a 11n
Use
52
11g 11n
5180
48
Guatemala
PWR
(EIRP)
400 mW Indoor + outdoor
140
5700
11a 11n
149
165
5745
5825
400 mW Indoor + outdoor
11g 11n
2412
100 mW Indoor + outdoor
11a 11n
TPC
11a 11n
DFS + TPC
13
2472
36
5180
48
5240
52
5260
64
200 mW Indoor only
200 mW Indoor only
5320
Approvals SCALANCE W700 802.11n
26
Reference Manual, 01/2017, C79000-G8976-C392-05
ApprovalsforSCALANCEW780/W740802.11n
1.3 National approvals
Country
Mode
CH
MHz
100
11g 11n
11a 11n
TPC
11a 11n
DFS + TPC
11a 11n
5580
5660
5700
2412
13
2472
36
5180
11g 11n
48
5240
5260
11a 11n
TPC
5320
149
5745
11a 11n
DFS + TPC
5825
2412
Indonesia ♦
11g 11n
2472
36
5180
200 mW Indoor + outdoor
100 mW Indoor + outdoor
200 mW Indoor only
48
5240
52
5260
200 mW Indoor only
64
5320
2412
100 mW Indoor + outdoor
2417
200 mW Indoor + outdoor
10
2457
11
2462
11a 11n
200 mW Indoor only
13
200 mW Indoor only
165
100 mW Indoor + outdoor
64
1000 mW Indoor + outdoor
52
1000 mW Indoor + outdoor
140
Use
132
Israel
5500
116
India
PWR
(EIRP)
13
2472
149
5745
161
100 mW Indoor + outdoor
400 mW Indoor + outdoor
5805
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
27
ApprovalsforSCALANCEW780/W740802.11n
1.3 National approvals
Country
Mode
Japan
11g 11n
CH
MHz
2412
200 mW Indoor + outdoor
13
2472
16
5040
5080
200 mW Indoor + outdoor
11a 11n
36
5180
200 mW Indoor only
11a 11n
DFS + TPC
11a
11g 11n
5240
52
5260
TPC
11a 11n
DFS + TPC
5320
100
5500
11a 11n
200 mW Indoor + outdoor
140
5700
184
196
4920
4980
200 mW Indoor + outdoor
2412
100 mW Indoor + outdoor
13
2472
36
5180
5240
52
5260
100 mW Indoor only
48
100 mW Indoor only
64
5320
132
5660
11g 11n
200 mW Indoor only
64
11a 11n
48
Qatar
Use
11a
Kazakhstan
PWR
(EIRP)
100 mW Indoor + outdoor
140
5700
2412
13
2472
149
165
5745
5825
100 mW Indoor only
100 mW Indoor only
Approvals SCALANCE W700 802.11n
28
Reference Manual, 01/2017, C79000-G8976-C392-05
ApprovalsforSCALANCEW780/W740802.11n
1.3 National approvals
Country
Mode
Colombia
11g 11n
CH
MHz
2412
100 mW Indoor + outdoor
2417
200 mW Indoor + outdoor
DFS + TPC
2457
11
2462
100 mW Indoor + outdoor
36
5180
200 mW Indoor only
48
5240
5260
5320
100
5500
11g 11n
11a 11n
TPC
5580
132
5660
Kuwait
11g 11n
11a 11n
TPC
5700
149
5745
11a 11n
DFS + TPC
5825
2412
13
2472
149
5745
5805
2412
13
2472
36
5180
400 mW Indoor + outdoor
100 mW Indoor + outdoor
200 mW Indoor + outdoor
48
5240
52
5260
400 mW Indoor + outdoor
161
64
400 mW Indoor + outdoor
165
400 mW Indoor + outdoor
140
400 mW Indoor + outdoor
116
400 mW Indoor + outdoor
64
Korea
52
11a 11n
10
11a 11n
Use
11a 11n
PWR
(EIRP)
200 mW Indoor + outdoor
5320
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
29
ApprovalsforSCALANCEW780/W740802.11n
1.3 National approvals
Country
Mode
Macau
11g 11n
13
2412
2472
100 mW Indoor + outdoor
11a 11n
149
161
5745
5805
100 mW Indoor + outdoor
11g 11n
13
2412
2472
100 mW Indoor + outdoor
11a 11n
5180
5240
200 mW Indoor only
TPC
36
48
5260
5320
200 mW Indoor only
DFS + TPC
52
64
100
5500
Madagascar
CH
11a 11n
MHz
5580
132
5660
Malaysia
11g 11n
5700
149
5745
11a 11n
DFS
5825
2412
11a 11n
2472
56
5280
200 mW Indoor + outdoor
200 mW Indoor only
64
5320
149
5745
400 mW Indoor + outdoor
13
1000 mW Indoor + outdoor
165
1000 mW Indoor + outdoor
140
Use
116
11a 11n
PWR
(EIRP)
1000 mW Indoor + outdoor
165
5825
Morocco ♦
11g 11n
13
2412
2472
100 mW Indoor only
(only with
SCALANCE
W786-2IA RJ-45)
11a 11n
5180
5240
200 mW Indoor only
TPC
36
48
5260
5320
200 mW Indoor only
DFS + TPC
52
64
11a 11n
Approvals SCALANCE W700 802.11n
30
Reference Manual, 01/2017, C79000-G8976-C392-05
ApprovalsforSCALANCEW780/W740802.11n
1.3 National approvals
Country
Mode
Mexico
11g 11n
CH
11a 11n
MHz
2412
11
2462
36
5180
11g 11n
11a 11n
TPC
5320
149
5745
11a 11n
DFS + TPC
5825
2412
13
2472
36
5180
5240
52
5260
64
5320
5500
Oman
11g 11n
11a 11n
TPC
5580
132
5660
11a 11n
DFS + TPC
11a 11n
5700
2412
13
2472
36
5180
5240
52
5260
Pakistan
11g 11n
64
5320
5745
11a 11n
5825
2412
2472
149
5745
165
100 mW Indoor + outdoor
200 mW Indoor only
200 mW Indoor only
1000 mW Indoor + outdoor
100 mW Indoor + outdoor
13
1000 mW Indoor + outdoor
165
1000 mW Indoor + outdoor
149
200 mW Indoor only
48
200 mW Indoor only
140
100 mW Indoor + outdoor
116
1000 mW Indoor + outdoor
100
1000 mW Indoor + outdoor
48
500 mW Indoor + outdoor
165
Use
64
Mozambique
PWR
(EIRP)
100 mW Indoor + outdoor
5825
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
31
ApprovalsforSCALANCEW780/W740802.11n
1.3 National approvals
Country
Mode
Russia
11g 11n
CH
11a 11n
TPC
11a 11n
DFS + TPC
MHz
2412
13
2472
36
5180
5240
52
5260
Saudi Arabia
11g 11n
11a 11n
TPC
5320
132
5660
11a 11n
DFS + TPC
5700
149
5745
5825
2412
13
2472
36
5180
5240
52
5260
5320
100
5500
100 mW Indoor + outdoor
200 mW Indoor only
200 mW Indoor only
1000 mW Indoor + outdoor
116
5580
132
5660
100 mW Indoor + outdoor
64
140
100 mW Indoor + outdoor
48
100 mW Indoor + outdoor
165
100 mW Indoor + outdoor
140
100 mW Indoor + outdoor
64
Use
48
11a 11n
PWR
(EIRP)
1000 mW Indoor + outdoor
5700
Approvals SCALANCE W700 802.11n
32
Reference Manual, 01/2017, C79000-G8976-C392-05
ApprovalsforSCALANCEW780/W740802.11n
1.3 National approvals
Country
Mode
Serbia
11g 11n
CH
Use
2412
2472
100 mW Indoor + outdoor
36
48
5180
5240
200 mW Indoor only
TPC
52
64
5260
5320
200 mW Indoor only
DFS + TPC
100
116
5500
5580
1000 mW Indoor + outdoor
132
140
5660
5700
1000 mW Indoor + outdoor
11g 11n
13
2412
2472
100 mW Indoor + outdoor
11a 11n
5180
5240
200 mW Indoor only
TPC
36
48
52
64
5260
5320
200 mW Indoor only
DFS + TPC
100
116
5500
5580
1000 mW Indoor + outdoor
132
140
5660
5700
1000 mW Indoor + outdoor
2412
100 mW Indoor + outdoor
11a 11n
11a 11n
Singapore
PWR
(EIRP)
13
11a 11n
South Africa
MHz
11g 11n
Philippines
11a 11n
TPC
11a 11n
DFS + TPC
13
2472
36
5180
48
5240
52
5260
200 mW Indoor + outdoor
200 mW Indoor + outdoor
64
5320
100
116
5500
5580
1000 mW Indoor + outdoor
132
140
5660
5700
1000 mW Indoor + outdoor
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
33
ApprovalsforSCALANCEW780/W740802.11n
1.3 National approvals
Country
Mode
11a 11n
CH
MHz
149
Taiwan
11g 11n
11a 11n
DFS + TPC
11a 11n
11g 11n
11a 11n
DFS + TPC
11a 11n
1000 mW Indoor + outdoor
5825
2412
100 mW Indoor + outdoor
2417
200 mW Indoor + outdoor
10
2457
11
2462
100 mW Indoor + outdoor
52
5260
400 mW Indoor + outdoor
64
5320
100
116
5500
5580
400 mW Indoor + outdoor
132
140
5660
5700
400 mW Indoor + outdoor
149
5745
400 mW Indoor + outdoor
165
5825
2412
11
2462
36
5180
11a 11n
5745
Use
165
Thailand
PWR
(EIRP)
200 mW Indoor only
48
5240
52
5260
100 mW Indoor + outdoor
400 mW Indoor + outdoor
64
5320
100
116
5500
5580
400 mW Indoor + outdoor
132
140
5660
5700
400 mW Indoor + outdoor
149
5745
400 mW Indoor + outdoor
165
5825
Approvals SCALANCE W700 802.11n
34
Reference Manual, 01/2017, C79000-G8976-C392-05
ApprovalsforSCALANCEW780/W740802.11n
1.3 National approvals
Country
Mode
Ukraine
11g 11n
CH
11a 11n
TPC
11a 11n
DFS + TPC
MHz
2412
13
2472
36
5180
5240
52
5260
11g 11n
11a 11n
5320
100
5500
DFS + TPC
11a 11n
TC
200 mW Indoor + outdoor
200 mW Indoor + outdoor
200 mW Indoor + outdoor
116
5580
132
5660
200 mW Indoor + outdoor
136
5680
2412
100 mW Indoor + outdoor
2417
200 mW Indoor + outdoor
10
2457
11
2462
100 mW Indoor + outdoor
36
5180
200 mW Indoor only
11a 11n
100 mW Indoor + outdoor
64
Use
48
Uruguay
PWR
(EIRP)
48
5240
52
5260
400 mW Indoor + outdoor
64
5320
100
116
5500
5580
400 mW Indoor + outdoor
132
140
5660
5700
400 mW Indoor + outdoor
149
5745
400 mW Indoor + outdoor
165
5825
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
35
ApprovalsforSCALANCEW780/W740802.11n
1.3 National approvals
Country
Mode
Venezuela
11g 11n
CH
11a 11n
MHz
2412
13
2472
36
5180
11a 11n
DFS
11a 11n
5240
52
5260
11g 11n
11a 11n
TPC
5320
149
5745
11a 11n
DFS + TPC
5825
2412
2472
36
5180
5240
52
5260
5320
100
5500
200 mW Indoor only
200 mW Indoor only
1000 mW Indoor only
116
5580
132
5660
140
100 mW Indoor + outdoor
64
4000 mW Indoor + outdoor
48
1000 mW Indoor only
13
200 mW Indoor only
165
1000 mW Indoor + outdoor
64
Use
48
United Arab Emirates
PWR
(EIRP)
1000 mW Indoor only
5700
Approvals SCALANCE W700 802.11n
36
Reference Manual, 01/2017, C79000-G8976-C392-05
ApprovalsforSCALANCEW780/W740802.11n
1.3 National approvals
Country
Mode
Bahamas
11g 11n
CH
Ecuador
Canada
MHz
PWR
(EIRP)
Use
2412
100 mW Indoor + outdoor
2417
200 mW Indoor + outdoor
Peru
10
2457
Puerto Rico
11
2462
100 mW Indoor + outdoor
36
5180
200 mW Indoor only
USA
11a 11n
11a 11n
DFS + TPC
11a 11n
48
5240
52
5260
11g 11n
11a 11n
TPC
11a 11n
DFS + TPC
5320
100
116
5500
5580
400 mW Indoor + outdoor
132
140
5660
5700
400 mW Indoor + outdoor
149
5745
400 mW Indoor + outdoor
165
5825
2412
13
2472
36
5180
5240
52
5260
5320
100
5500
5580
132
5660
1000 mW Indoor + outdoor
1000 mW Indoor + outdoor
140
5700
149
5745
165
200 mW Indoor only
116
200 mW Indoor only
64
100 mW Indoor + outdoor
48
11a 11n
400 mW Indoor + outdoor
64
Vietnam
400 mW Indoor + outdoor
5825
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
37
ApprovalsforSCALANCEW780/W740802.11n
1.3 National approvals
Approvals SCALANCE W700 802.11n
38
Reference Manual, 01/2017, C79000-G8976-C392-05
Approvals for SCALANCE W788C / W786C 802.11n
Note
Issued approvals on the type plate of the device
The specified approvals apply only when the corresponding mark is printed on the product.
You can check which of the following approvals have been granted for your product by the
markings on the type plate.
Range of validity
The approvals listed in this section apply to the following products:
Article number
SCALANCE W786C-2 RJ-45
6GK5 786-2FC00-1AA0
SCALANCE W786C-2IA RJ-45
6GK5 786-2HC00-1AA0
SCALANCE W786C-2 SFP
6GK5 786-2FE00-1AA0
SCALANCE W788C-2 RJ-45
6GK5 788-2FC00-1AA0
SCALANCE W788C-2 M12
6GK5 788-2GD00-1AA0
SCALANCE W788C-2 M12 EEC
6GK5788-2GD00-1TA0
Article number
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
39
Approvals for SCALANCE W788C / W786C 802.11n
2.1 EC declaration of conformity
2.1
EC declaration of conformity
The EC Declaration of Conformity is available for all responsible authorities at:
Siemens Aktiengesellschaft
Process Industries and Drives Division,
Process Automation
DE-76181 Karlsruhe
Germany
You will find the current EC declaration of conformity for these products on the Internet
pages of Siemens Industry Online Support
(hhttps://support.industry.siemens.com/cs/ww/en/ps/15853/cert).
The SIMATIC NET products described in these Operating Instructions meet the
requirements of the following EC directives:
● 94/9/EC
Directive of the European Parliament and the Council of 23 March 1994 on the
approximation of the laws of the Member States concerning equipment and protective
systems intended for use in potentially explosive atmospheres (until 19.04.2016).
● 2014/34/EU
Directive 2014/34/EU of the European Parliament and of the Council of 26 February 2014
on the harmonization of the laws of the Member States relating to equipment and
protective systems intended for use in potentially explosive atmospheres official journal of
the EU L96, 29/03/2014, pages. 309–356 (as of 20.04.2016)
● 1999/5/EC
Directive of the European Parliament and of the Council of 1999 March 1999 on Radio
Equipment and Telecommunications Terminal Equipment and the mutual recognition of
their conformity (until 12.06.2016).
● 2014/53/EU
Directive of the European Parliament and of the Council of April 16, 2014 on the
harmonization of the laws of the member states relating to placing radio equipment on the
market.; official journal of the EU L153, 22/05/2014, pages. 62–106 (as of 13.06.2016)
● 2011/65/EU (RoHS)
RoHS directive of the European Parliament and of the Council of 8 June 2011 on the
restriction of the use of certain hazardous substances in electrical and electronic
equipment.
● 1999/519/EC
Council recommendation on the limitation of exposure of the general public to
electromagnetic fields (0 Hz to 300 GHz)
Approvals SCALANCE W700 802.11n
40
Reference Manual, 01/2017, C79000-G8976-C392-05
Approvals for SCALANCE W788C / W786C 802.11n
2.1 EC declaration of conformity
2.1.1
ATEX
ATEX directive (correct usage in potentially explosive atmospheres)
The SIMATIC NET product meets the requirements of the EC directive:94/9/EC (until
19.04.2016) and 2014/34/EU (as of 20.04.2016) "Equipment and Protective Devices for Use
in Potentially Explosive Atmospheres" according to the standards listed in the section
Products (Page 43):
Applied standard:
EN 60079-0 + A11
Hazardous areas - Part 0: Equipment - General requirements
EN 60079-15
Explosive atmospheres - Part 15: Equipment protection by type of protection "n"
2.1.2
RoHS
RoHS directive (restriction of the use of certain hazardous substances)
The SIMATIC NET products described in these operating instructions meet the requirements
of the EC directive 2011/65/EC for the restriction of the use of certain hazardous substances
in electrical and electronic equipment:
Applied standard:
EN 50581
Technical documentation for the assessment electrical and electronic products with
respect to restriction of hazardous substances
2.1.3
R&TTE / RED
2.1.3.1
Protection of health and safety
Article 3 (1) a) protection of health and safety
EN 60950-1+A1+A2+A11+A12
Information technology equipment - Safety - Part 1: General requirements
EN 62311
Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz – 300 GHz)
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
41
Approvals for SCALANCE W788C / W786C 802.11n
2.1 EC declaration of conformity
2.1.3.2
Efficient use of the radio spectrum
Art. 3 (2) Efficient use of the radio spectrum
2.1.3.3
14
ETSI EN 301 328
Electromagnetic compatibility and radio spectrum matters (ERM) - wideband
transmission systems - data transmission equipment operating in the 2.4 GHz ISM
band and using wideband modulation techniques. Harmonized EN containing the
essential requirements according to Article 3.2 of the R&TTE directive.
15
ETSI EN 301 893
Broadband Radio Access Networks (BRAN) - 5 GHz high performance RLAN Harmonized EN covering essential requirements of article 3.2 of the R&TTE Directive
EMC
Art. 3 (1) b - EMC
EN 50121-3-2+AC
Railway applications - Electromagnetic compatibility - part 3-2: Railway Vehicles Devices
EN 50121-4+AC
Railway applications - Electromagnetic compatibility - part 4: Interference emissions
and immunity of signal telecommunications equipment
ETSI EN 301 489-1
Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic
compatibility for radio equipment and services - Part 1 : Common technical requirements
ETSI EN 301 489-17
Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic
compatibility for radio equipment and services - Part 17 :
10
EN 61000-6-1
Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for
residential, commercial and light-industrial environments
EN 61000-6-2+AC
Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for
industrial environments
EN 61000-6-3+A1+AC
Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission
standard for residential, commercial and light-industrial environments
EN 61000-6-4+A1
Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission
standard for industrial environments
11
12
13
Approvals SCALANCE W700 802.11n
42
Reference Manual, 01/2017, C79000-G8976-C392-05
Approvals for SCALANCE W788C / W786C 802.11n
2.1 EC declaration of conformity
2.1.4
Products
Product designation and standards
The standards that apply to the product are described in RoHS (Page 41), ATEX (Page 41)
and R&TTE / RED (Page 41).
Product name
Standards
W786C-2 RJ45
1, 2 3, 4, 5, 8, 9, 10, 11, 12, 13, 14, 15, 16
W786C-2IA RJ45
W786-2 SFP
W788C-2 RJ45
W788C-2 M12
W788C-2 M12 EEC
1, 2 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16
Certification ID
The following tables show the product names and the corresponding certification ID:
Type
W786C-2 RJ-45
Number and type of
Number of interthe Ethernet interfaces nal antennas
Number of R-SMA
sockets for external
antennas
Certification ID
Article number
Article number US variant
1 x RJ-45
EAPN-W2-RJ-E3
6GK5 786-2FC00-1AA0
W786C-2IA RJ-45 1 x RJ-45
EAPN-W2-RJ-I3
6GK5 786-2HC00-1AA0
W786-2 SFP
EAPN-W2-SFP-E3
6GK5 786-2FE00-1AA0
2 x SFP
Type
Certification ID
Article number:
W788C-2 RJ-45
RAPN-W2-RJ-E3
6GK 5788-2FC00-1AA0
W788C-2 M12
RAPN-W2-M12-E3
6GK5 788-2GD00-1AA0
W788C-2 M12 EEC
RAPN-W2-M12-E3
6GK5788-2GD00-1TA0
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
43
Approvals for SCALANCE W788C / W786C 802.11n
2.2 General approvals
2.2
General approvals
ATEX (explosion protection directive)
WARNING
When using SIMATIC NET products in hazardous area zone 2, make absolutely sure that
the associated conditions in the following document are adhered to:
"SIMATIC NET Product Information Use of subasseblies/modules in a Zone 2 Hazardous
Area".
You will find this document
on the data medium that ships with some devices.
on the Internet pages of Siemens Industry Online Support
(http://support.automation.siemens.com/ww).
Enter the document identification number C234 as the search term.
The SIMATIC NET products meet the requirements of the EC directive 94/9/EC "Equipment
and Protective Devices for Use in Potentially Explosive Atmospheres”. and as of 20.04.2016
the EC directive 2014/34/EU.
ATEX classification:
II 3 G Ex nA IIC T4 Gc
KEMA 07ATEX0145 X
The products meet the requirements of the following standards:
● EN 60079-15 (electrical apparatus for potentially explosive atmospheres; Type of
protection "n")
● EN 60079-0 (Explosive atmospheres - Part 0: Equipment - General requirements)
You will find the current versions of the standards in the currently valid ATEX certificates.
Approvals SCALANCE W700 802.11n
44
Reference Manual, 01/2017, C79000-G8976-C392-05
Approvals for SCALANCE W788C / W786C 802.11n
2.2 General approvals
IECEx
The SIMATIC NET products meet the requirements of explosion protection according to
IECEx.
IECEx classification:
Ex nA IIC T4 Gc
DEK 14.0025X
The products meet the requirements of the following standards:
● IEC 60079-15 (Explosive atmospheres - Part 15: Equipment protection by type of
protection "n")
● IEC 60079-0 (Explosive atmospheres - Part 0: Equipment - General requirements)
You will find the current versions of the standards in the currently valid IECEx certificates.
FM
The product meets the requirements of the standards:
● Factory Mutual Approval Standard Class Number 3611
● FM Hazardous (Classified) Location Electrical Equipment:
Non Incendive / Class I / Division 2 / Groups A,B,C,D / T4 and
Non Incendive / Class I / Zone 2 / Group IIC / T4
cULus Approval Hazardous Location
cULus Listed I. T. E. FOR HAZ. LOC.
Underwriters Laboratories Inc. complying with
● UL 60950-1 (Information Technology Equipment)
● ANSI/ISA 12.12.01-2007
● CSA C22.2 No. 213-M1987
Approved for use in
Cl. 1, Div. 2, GP A, B, C, D T4
Cl. 1, Zone 2, GP IIC T4
Report no. E240480
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
45
Approvals for SCALANCE W788C / W786C 802.11n
2.2 General approvals
FCC approval
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause
undesired operation.
Notice
Changes or modifications made to this equipment not expressly approved by SIEMENS may
void the FCC authorization to operate this equipment.
IEEE 802.11b or g operation of this product in the USA is firmware-limited to channels 1
through 11.
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
● Reorient or relocate the receiving antenna.
● Increase the separation between the equipment and receiver.
● Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
● Consult the dealer or an experienced radio/TV technician for help.
Notice
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance 20 cm
between the radiator and your body.
This transmitter must not be co-located or operating in conjunction with any other antenna or
transmitter. Professional Installation Notice:
To comply with FCC part 15 rules in the United States, the system must be professionally
installed to ensure compliance with the Part 15 certification. It is the responsibility of the
operator and professional installer to ensure that only certified systems are deployed in the
United States. The use of the system in any other combination (such as co-located antennas
transmitting the same information) is expressly forbidden.
Approvals SCALANCE W700 802.11n
46
Reference Manual, 01/2017, C79000-G8976-C392-05
Approvals for SCALANCE W788C / W786C 802.11n
2.2 General approvals
Notice
For use of DFS channels
● Use of the RCoax Cable Antenna 6XV1875-2D is not permitted in channels which
require dynamic frequency selection (DFS).
● Any installation of either a master or a client device within 35 km of a TDWR (Terminal
Doppler Weather Radar) location shall be separated by at least 30 MHz (center-to-center)
from the TDWR operating frequency.
These devices shall be registered in the industry sponsored WISPA database,
http://udia.spectrumbridge.com/udia/home.aspx
(http://udia.spectrumbridge.com/udia/home.aspx)
When you open this link, you get the following choices:
– "Search" opens a window with TDWR locations and frequencies.
– "User Signup" allows you to register as user of the database.
– After registering you can Logon and register your WLAN location. Please fill in all
required information.
For more information with respect to WISPA database and TWDR locations please consult
FCC publication KDB 443999 D01.
NEMA TS2
The product meets the requirements of the standard
NEMA TS2 (Traffic Controller Assemblies with NTCIP Requirements)
SCALANCE W788C-2 M12 EEC
6GK5788-2GD00-1TA0
RSS-247 of Industry Canada for SCALANCE W786-x
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) this device may not cause
interference, and (2) this device must accept any interference, including interference that
may cause undesired operation of the device.
This radio transmitter (IC: 267AA-MPCIE1V1) has been approved by Industry Canada to
operate with the antenna types listed in section 6.8 with the maximum permissible gain and
required antenna impedance for each antenna type indicated. Antenna types not included in
this list, having a gain greater than the maximum gain indicated for that type, are strictly
prohibited for use with this device.
Under Industry Canada regulations, this radio transmitter may only operate using an antenna
of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To
reduce potential radio interference to other users, the antenna type and its gain should be so
chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that
necessary for successful communication.
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
47
Approvals for SCALANCE W788C / W786C 802.11n
2.2 General approvals
To reduce potential radio interference to other users, the antenna type and its gain should be
so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that
permitted for successful communication.
That the device for the band 5150-5250 MHz is only for indoor usage to reduce potential for
harmful interference to co-channel mobile satellite systems.
Users should also be cautioned to take note that high power radars are allocated as primary
users (meaning they have priority) of 5250-5350 MHz and 5650-5850 MHz and these radars
could cause interference and/or damage to LE-LAN devices.
This equipment complies with IC RSS-102 radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with minimum
distance 20cm between the radiator & your body.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils
radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1)
l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout
brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le
fonctionnement.
RSS-247 of Industry Canada for SCALANCE W7x8
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) this device may not cause
interference, and (2) this device must accept any interference, including interference that
may cause undesired operation of the device.
This radio transmitter (IC: 267AA-MPCIE1V1) has been approved by Industry Canada to
operate with the antenna types listed in section 5.4 with the maximum permissible gain and
required antenna impedance for each antenna type indicated. Antenna types not included in
this list, having a gain greater than the maximum gain indicated for that type, are strictly
prohibited for use with this device.
Under Industry Canada regulations, this radio transmitter may only operate using an antenna
of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To
reduce potential radio interference to other users, the antenna type and its gain should be so
chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that
necessary for successful communication.
To reduce potential radio interference to other users, the antenna type and its gain should be
so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that
permitted for successful communication.
That the device for the band 5150-5250 MHz is only for indoor usage to reduce potential for
harmful interference to co-channel mobile satellite systems.
Users should also be cautioned to take note that high power radars are allocated as primary
users (meaning they have priority) of 5250-5350 MHz and 5650-5850 MHz and these radars
could cause interference and/or damage to LE-LAN devices.
This equipment complies with IC RSS-102 radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with minimum
distance 20cm between the radiator & your body.
Approvals SCALANCE W700 802.11n
48
Reference Manual, 01/2017, C79000-G8976-C392-05
Approvals for SCALANCE W788C / W786C 802.11n
2.2 General approvals
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils
radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1)
l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout
brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le
fonctionnement.
Note for USA, Canada, Puerto Rico, Peru, Bahamas, Ecuador and Columbia
When operating the SCALANCE W700 with DFS (Dynamic Frequence Selection), the
IWLAN RCoax Cable 5 GHz (order number 6XV1875-2D) may not be used in the countries
listed above.
Approvals in Argentina
Devices of the SCALANCE W786-x series are approved in Argentina under the following
certification numbers:
Certification ID
Certification number
EAPN-W1-RJ-E3
CNC: C-11549
EAPN-W2-RJ-E3
CNC: C-11536
EAPN-W2-RJ-I3
CNC: C-11564
EAPN-W2-SFP-E3
CNC: C-11547
Devices of the SCALANCE W788-x series are approved in Argentina under the following
certification numbers:
Certification ID
Certification number
RAPN-W1-RJ-E3
CNC: C-11541
RAPN-W2-RJ-E3
CNC: C-11502
RAPN-W1-M12-E3
CNC: C-11546
RAPN-W2-M12-E3
CNC: C-11548
Approval in Brazil
From the SCALANCE W786-x series, the following devices are approved for Brazil:
Type
Order number
EAPN number
W786-1 RJ-45
6GK5 786-1FC00-0AA0
EAPN-W1-RJ-E3
W786-2 RJ-45
6GK5 786-2FC00-0AA0
EAPN-W2-RJ-E3
W786C-2 RJ-45
6GK5 786-2FC00-1AA0
EAPN-W2-RJ-E3
W786-2IA RJ-45
6GK5 786-2HC00-0AA0
EAPN-W2-RJ-I3
W786C-2IA RJ-45
6GK5 786-2HC00-1AA0
EAPN-W2-RJ-I3
W786-2 SFP
6GK5 786-2FE00-0AA0
EAPN-W2-SFP-E3
The listed devices are approved in Brazil under the following certification numbers:
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
49
Approvals for SCALANCE W788C / W786C 802.11n
2.2 General approvals
Este equipamento opera em caráter secundário, isto, ist é, não tem direito à proteção contra
interferência prejudicial, mesmo de estações do mesmo tipo e não pode causar interferência
a sistemas operando em caráter primário.
From the SCALANCE W7x8 series, the following devices are approved for Brazil:
Type
Order number
RAPN number
W788-1 RJ-45
6GK 5788-1FC00-0AA0
RAPN-W1-RJ-E3
W788-2 RJ-45
6GK5 788-2FC00-0AA0
RAPN-W2-RJ-E3
W788-1 M12
6GK5 788-1GD00-0AA0
RAPN-W1-M12-E3
W788-2 M12
6GK5 788-2GD00-0AA0
RAPN-W2-M12-E3
W788-2 M12 EEC
6GK5 788-2GD00-0TA0
RAPN-W2-M12-E3
W748-1 RJ-45
6GK5 748-1FC00-0AA0
RAPN-W1-RJ-E3
W748-1 M12
6GK5 748-1GD00-0AA0
RAPN-W1-M12-E3
W788C-2 RJ-45
6GK 5788-2FC00-1AA0
RAPN-W2-RJ-E3
W788C-2 M12
6GK5 788-2GD00-1AA0
RAPN-W2-M12-E3
W788C-2 M12 EEC
6GK5788-2GD00-1TA0
RAPN-W2-M12-E3
The listed devices are approved in Brazil under the following certification numbers:
Este equipamento opera em caráter secundário, isto, ist é, não tem direito à proteção contra
interferência prejudicial, mesmo de estações do mesmo tipo e não pode causar interferência
a sistemas operando em caráter primário.
Approval for Mexico
The WLAN modules included in the devices have the following certification number:
RCPSIMP12-0751
Approvals SCALANCE W700 802.11n
50
Reference Manual, 01/2017, C79000-G8976-C392-05
Approvals for SCALANCE W788C / W786C 802.11n
2.2 General approvals
Approval for Oman
Devices of the SCALANCE W786-x series are approved in Oman under the following
certification numbers:
OMAN-TRA
R/1773/14
D090258
Devices of the SCALANCE W788-x series are approved in Oman under the following
certification numbers:
OMAN-TRA
R/1772/14
D090258
Marking for the customs union
EAC (Eurasian Conformity)
Customs union of Russia, Belarus and Kazakhstan
Declaration of the conformity according to the technical regulations of the customs union
(TR CU)
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
51
Approvals for SCALANCE W788C / W786C 802.11n
2.3 National approvals
2.3
National approvals
The national approval of the controller-based access points depends on the controller on
which they are operated. The controllers are available in the following country-specific
versions:
● Version for the USA and Canada (NAM)
Article no. 6GK5 711-0XC00-1AB0
These countries are indicated in the table (NAM).
● Version for the Japan (JP)
Article no. 6GK5 711-0XC00-1AD0
● Version for countries outside Japan and NAM (RoW)
Article no. 6GK5 711-0XC00-1AA0
The diamond symbol (♦) identifies all countries for which there was no approval at the time
these operating instructions were written.
The current status of the approvals can be found on the Internet at the following address:
http://www.siemens.com/funkzulassungen
Column
Meaning
Country
Country
Mode
IEEE 802.11 standard and the TPC and / or DFS functionality, where required
CH
Channel
MHz
Frequency
PWR (EIRP)
Maximum permitted effective isotropic radiated power
Use
Permitted use indoors and / or outdoors
Approvals SCALANCE W700 802.11n
52
Reference Manual, 01/2017, C79000-G8976-C392-05
Approvals for SCALANCE W788C / W786C 802.11n
2.3 National approvals
Country
Mode
Andorra
Belgium
Bulgaria
Denmark
Germany
Estonia
Finland
France
Greece
Great Britain
Ireland
Iceland
Italy
Croatia
Latvia
Liechtenstein
Lithuania
Luxembourg
Malta
Macedonia
Monaco
Montenegro
Netherlands
Norway
Austria
Poland
Portugal
Romania
San Marino
Sweden
Switzerland
Serbia
Slovakia
Slovenia
Spain
Czech Republic
Turkey
Hungary
Vatican
Cyprus
11g 11n
Egypt
11g 11n
CH
MHz
PWR
(EIRP)
Use
13
2412
2472
100 mW Indoor + outdoor
36
48
5180
5240
200 mW Indoor only
TPC
52
64
5260
5320
200 mW Indoor only
DFS + TPC
100
116
5500
5580
1000 mW Indoor + outdoor
132
140
5660
5700
1000 mW Indoor + outdoor
2412
100 mW Indoor + outdoor
11a 11n
11h 11n
11a 11n
TPC
13
2472
36
5180
64
200 mW Indoor only
5320
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
53
Approvals for SCALANCE W788C / W786C 802.11n
2.3 National approvals
Country
Mode
Angola
11g 11n
CH
11a 11n
TPC
11h 11n
DFS + TPC
MHz
2412
13
2472
36
5180
5240
52
5260
11g 11n
11a 11n
TPC
5320
100
5500
5580
132
5660
5700
2412
13
2472
36
5180
5240
52
5260
5320
100
5500
5600
132
5660
50 mW Indoor + outdoor
250 mW Indoor + outdoor
250 mW Indoor + outdoor
250 mW Indoor + outdoor
140
5700
149
5745
165
1000 mW Indoor + outdoor
120
1000 mW Indoor + outdoor
64
1000 mW Indoor + outdoor
48
200 mW Indoor only
140
200 mW Indoor only
116
100 mW Indoor + outdoor
64
Use
48
Argentina
PWR
(EIRP)
1000 mW Indoor + outdoor
5825
Approvals SCALANCE W700 802.11n
54
Reference Manual, 01/2017, C79000-G8976-C392-05
Approvals for SCALANCE W788C / W786C 802.11n
2.3 National approvals
Country
Mode
Australia
11g 11n
CH
New Zealand
11a 11n
TPC
11h 11n
DFS + TPC
11a 11n
TPC
Bahrain
11g 11n
MHz
2412
13
2472
36
5180
5240
52
5260
TPC
5320
149
5745
11h 11n
DFS + TPC
5825
2412
11a 11n
TPC
Belarus
11g 11n
11a 11n
TCP
11a 11n
TCP + DFS
2472
36
5180
48
5240
5260
5320
149
5745
5825
2412
13
2472
36
5180
5240
52
5260
2000 mW Indoor + outdoor
100 mW Indoor + outdoor
100 mW Indoor + outdoor
100 mW Indoor + outdoor
64
5320
132
5660
140
200 mW Indoor only
48
200 mW Indoor only
165
100 mW Indoor + outdoor
64
400 mW Indoor + outdoor
52
200 mW Indoor only
13
200 mW Indoor only
165
100 mW Indoor + outdoor
64
Use
48
11a 11n
PWR
(EIRP)
100 mW Indoor + outdoor
5700
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
55
Approvals for SCALANCE W788C / W786C 802.11n
2.3 National approvals
Country
Mode
Brazil
11g 11n
CH
11a 11n
TPC
MHz
2412
13
2472
36
5180
5320
100
5500
11g 11n
5700
149
5745
11a 11n
TPC
5825
2412
11a 11n
DFS + TPC
2472
36
5180
5240
52
5260
China
11g 11n
11a 11n
TPC
5320
149
5745
5825
2412
13
2472
149
5745
100 mW Indoor only
100 mW Indoor only
100 mW Indoor only
165
165
100 mW Indoor only
64
4000 mW Indoor + outdoor
48
1000 mW Indoor + outdoor
13
200 mW Indoor only
165
4000 mW Indoor + outdoor
140
Use
64
Chile
PWR
(EIRP)
100 mW Indoor + outdoor
2000 mW Indoor + outdoor
5825
Approvals SCALANCE W700 802.11n
56
Reference Manual, 01/2017, C79000-G8976-C392-05
Approvals for SCALANCE W788C / W786C 802.11n
2.3 National approvals
Country
Mode
Ivory Coast
11g 11n
CH
11a 11n
TPC
11a 11n
DFS + TPC
MHz
2412
13
2472
36
5180
5240
52
5260
11g 11n
11a 11n
TPC
11a 11n
DFS + TPC
5320
100
5500
5580
132
5660
200 mW Indoor only
1000 mW Indoor + outdoor
1000 mW Indoor + outdoor
140
5700
11
2412
2462
100 mW Indoor + outdoor
36
5180
200 mW Indoor only
48
5240
52
5260
400 mW Indoor + outdoor
64
5320
100
5500
400 mW Indoor + outdoor
116
5580
132
5660
TPC
200 mW Indoor only
116
11a 11n
100 mW Indoor + outdoor
64
Use
48
Guatemala
PWR
(EIRP)
400 mW Indoor + outdoor
140
5700
149
165
5745
5825
400 mW Indoor + outdoor
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
57
Approvals for SCALANCE W788C / W786C 802.11n
2.3 National approvals
Country
Mode
Hong Kong
11g 11n
CH
11a 11n
TPC
11a 11n
DFS + TPC
MHz
2412
13
2472
36
5180
5240
52
5260
11g 11n
11a 11n
TPC
5320
100
5500
11h 11n
DFS + TPC
5580
132
5660
11a 11n
5700
2412
13
2472
36
5180
Indonesia ♦
11g 11n
5240
52
5260
TPC
1000 mW Indoor + outdoor
100 mW Indoor + outdoor
200 mW Indoor only
200 mW Indoor only
64
5320
149
5745
200 mW Indoor + outdoor
165
5825
2412
100 mW Indoor + outdoor
2417
200 mW Indoor + outdoor
10
2457
11
2462
11a 11n
1000 mW Indoor + outdoor
48
200 mW Indoor only
140
200 mW Indoor only
116
100 mW Indoor + outdoor
64
Use
48
India
PWR
(EIRP)
13
2472
149
5745
161
100 mW Indoor + outdoor
400 mW Indoor + outdoor
5805
Approvals SCALANCE W700 802.11n
58
Reference Manual, 01/2017, C79000-G8976-C392-05
Approvals for SCALANCE W788C / W786C 802.11n
2.3 National approvals
Country
Mode
Japan
11g 11n
CH
11a
TPC
11a 11n
MHz
2412
13
2472
5040
12
5060
16
5080
36
5180
11h 11n
DFS + TPC
5240
52
5260
TPC
Qatar
Kazakhstan
11g 11n
64
5320
5500
200 mW Indoor + outdoor
200 mW Indoor only
200 mW Indoor only
200 mW Indoor + outdoor
140
5799
184
4920
200 mW Indoor + outdoor
196
4980
2412
100 mW Indoor only
13
2472
11a 11n
149
165
5745
5825
100 mW Indoor only
11g 11n
2412
100 mW Indoor + outdoor
11a 11n
TPC
11a 11n
DFS + TPC
11g 11n
13
2472
36
5180
5240
52
5260
100 mW Indoor only
48
100 mW Indoor only
64
5320
132
5660
Colombia (NAM)
200 mW Indoor + outdoor
100
Use
48
11a
PWR
(EIRP)
100 mW Indoor + outdoor
140
5700
2412
100 mW Indoor + outdoor
2417
200 mW Indoor + outdoor
10
2457
11
2462
100 mW Indoor + outdoor
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
59
Approvals for SCALANCE W788C / W786C 802.11n
2.3 National approvals
Country
Mode
CH
11a 11n
MHz
36
TPC
11g 11n
11a 11n
TPC
Kuwait
11g 11n
5240
5745
TPC
5825
2412
13
2472
149
5745
11h 11n
DFS + TPC
5805
2412
Macau
400 mW Indoor + outdoor
400 mW Indoor + outdoor
100 mW Indoor + outdoor
13
2472
36
5180
200 mW Indoor + outdoor
48
5240
52
5260
400 mW Indoor + outdoor
161
200 mW Indoor only
165
Use
48
11a 11n
5180
149
Korea
PWR
(EIRP)
200 mW Indoor + outdoor
64
5320
11g 11n
13
2412
2472
100 mW Indoor + outdoor
11a 11n
149
161
5745
5805
100 mW Indoor + outdoor
TPC
Approvals SCALANCE W700 802.11n
60
Reference Manual, 01/2017, C79000-G8976-C392-05
Approvals for SCALANCE W788C / W786C 802.11n
2.3 National approvals
Country
Mode
Madagascar
11g 11n
CH
MHz
2412
2472
100 mW Indoor + outdoor
36
48
5180
5240
200 mW Indoor only
TPC
52
64
5260
5320
200 mW Indoor only
DFS + TPC
100
5500
11a 11n
11a 11n
TPC
5580
132
5660
11g 11n
11h 11n
DFS + TPC
11a 11n
TPC
11g 11n
11a 11n
DFS + TPC
11a 11n
TPC
5700
149
5745
5825
2412
13
2472
56
5280
5320
149
5745
5825
2412
11
2462
52
5180
5320
149
5745
165
1000 mW Indoor + outdoor
500 mW Indoor + outdoor
1000 mW Indoor + outdoor
64
200 mW Indoor only
165
200 mW Indoor + outdoor
64
400 mW Indoor + outdoor
165
1000 mW Indoor + outdoor
140
1000 mW Indoor + outdoor
116
Mexico (NAM)
Use
13
11a 11n
Malaysia
PWR
(EIRP)
1000 mW Indoor + outdoor
5825
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
61
Approvals for SCALANCE W788C / W786C 802.11n
2.3 National approvals
Country
Mode
Mozambique
11g 11n
CH
11a 11n
TPC
11h 11n
DFS + TPC
MHz
2412
13
2472
36
5180
5240
52
5260
11g 11n
11a 11n
TPC
5320
100
5500
11a 11n
DFS + TPC
5580
132
5660
11a 11n
TPC
Pakistan
11g 11n
5700
2412
13
2472
36
5180
5240
52
5260
11a 11n
TPC
5320
149
5745
5825
2412
200 mW Indoor only
200 mW Indoor only
1000 mW Indoor + outdoor
100 mW Indoor + outdoor
13
2472
149
5745
165
100 mW Indoor + outdoor
165
1000 mW Indoor + outdoor
64
1000 mW Indoor + outdoor
48
200 mW Indoor only
140
200 mW Indoor only
116
100 mW Indoor + outdoor
64
Use
48
Oman
PWR
(EIRP)
100 mW Indoor + outdoor
5825
Approvals SCALANCE W700 802.11n
62
Reference Manual, 01/2017, C79000-G8976-C392-05
Approvals for SCALANCE W788C / W786C 802.11n
2.3 National approvals
Country
Mode
Russia
11g 11n
CH
11a 11n
TPC
11a 11n
DFS + TPC
MHz
2412
13
2472
36
5180
5240
52
5260
TPC
Saudi Arabia
11g 11n
11a 11n
TPC
5320
132
5660
11h 11n
DFS + TPC
5700
149
5745
5825
2412
13
2472
36
5180
5240
52
5260
Singapore
11b 11g 11n
Philippines ♦
11a 11n
TPC
5320
100
5500
11a 11n
DFS + TPC
5580
132
5660
200 mW Indoor only
200 mW Indoor only
1000 mW Indoor + outdoor
1000 mW Indoor + outdoor
140
5700
2412
13
2472
36
5180
100 mW Indoor + outdoor
200 mW Indoor + outdoor
48
5240
52
5260
100 mW Indoor + outdoor
116
100 mW Indoor + outdoor
64
100 mW Indoor + outdoor
48
100 mW Indoor + outdoor
165
100 mW Indoor + outdoor
140
100 mW Indoor + outdoor
64
Use
48
11a 11n
PWR
(EIRP)
200 mW Indoor + outdoor
64
5320
100
116
5500
5580
1000 mW Indoor + outdoor
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
63
Approvals for SCALANCE W788C / W786C 802.11n
2.3 National approvals
Country
Mode
CH
11a 11n
TPC
South Africa
PWR
(EIRP)
Use
132
140
5660
5700
1000 mW Indoor + outdoor
149
5745
1000 mW Indoor + outdoor
165
5825
13
2412
2472
100 mW Indoor + outdoor
36
48
5180
5240
200 mW Indoor only
TPC
52
64
5260
5320
200 mW Indoor only
DFS + TPC
100
116
5500
5580
1000 mW Indoor + outdoor
132
140
5660
5700
1000 mW Indoor + outdoor
2412
100 mW Indoor + outdoor
2417
200 mW Indoor + outdoor
10
2457
11
2462
100 mW Indoor + outdoor
52
5260
400 mW Indoor + outdoor
11g 11n
11a 11n
11h 11n
Taiwan ♦
MHz
11g 11n
11a 11n
TPC
64
5320
100
5500
165
5825
Approvals SCALANCE W700 802.11n
64
Reference Manual, 01/2017, C79000-G8976-C392-05
Approvals for SCALANCE W788C / W786C 802.11n
2.3 National approvals
Country
Mode
Thailand
11g 11n
CH
11a 11n
TPC
11a 11n
DFS + TPC
11a 11n
TPC
Ukraine
11g 11n
11a 11n
TPC
11h 11n
DFS + TPC
MHz
PWR
(EIRP)
2412
11
2462
36
5180
100 mW Indoor + outdoor
200 mW Indoor only
48
5240
52
5260
Use
400 mW Indoor + outdoor
64
5320
100
116
5500
5580
400 mW Indoor + outdoor
132
140
5660
5700
400 mW Indoor + outdoor
149
5745
400 mW Indoor + outdoor
165
5825
2412
13
2472
36
5180
5240
52
5260
5320
100
5500
5580
132
5660
200 mW Indoor + outdoor
116
136
200 mW Indoor + outdoor
64
200 mW Indoor + outdoor
48
100 mW Indoor + outdoor
200 mW Indoor + outdoor
5680
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
65
Approvals for SCALANCE W788C / W786C 802.11n
2.3 National approvals
Country
Mode
Uruguay
11g
CH
11a
MHz
2412
11a 11n
200 mW
5180
200 mW Indoor only
11g 11n
5240
149
5745
TPC
11a 11n
DFS + TPC
11a 11n
TPC
400 mW Indoor + outdoor
165
5825
2412
100 mW Indoor + outdoor
11
2462
200 mW
36
5180
200 mW Indoor only
48
5240
149
5745
5825
2412
2472
36
5180
5240
52
5260
64
5320
5745
1000 mW Indoor only
149
165
200 mW Indoor only
48
1000 mW Indoor + outdoor
13
400 mW Indoor + outdoor
165
11a 11n
48
Venezuela
2462
11a 11n
100 mW Indoor + outdoor
36
11n 11g
Use
11
11a
PWR
(EIRP)
4000 mW Indoor + outdoor
5825
Approvals SCALANCE W700 802.11n
66
Reference Manual, 01/2017, C79000-G8976-C392-05
Approvals for SCALANCE W788C / W786C 802.11n
2.3 National approvals
Country
Mode
United Arab Emirates
11g 11n
CH
11a 11n
TPC
11h 11n
DFS + TPC
MHz
2412
13
2472
36
5180
5240
52
5260
11g 11n
Ecuador
Canada (NAM)
100 mW Indoor + outdoor
200 mW Indoor only
200 mW Indoor only
64
5320
100
5500
1000 mW Indoor only
116
5580
132
5660
Use
48
Bahamas (NAM)
PWR
(EIRP)
1000 mW Indoor only
140
5700
2412
100 mW Indoor + outdoor
2417
200 mW Indoor + outdoor
Peru
10
2457
Puerto Rico (NAM)
11
2462
100 mW Indoor + outdoor
52
5260
400 mW Indoor + outdoor
USA (NAM)
11a 11n
DFS + TPC
11a 11n
TPC
64
5320
100
116
5500
5580
400 mW Indoor + outdoor
132
140
5660
5700
400 mW Indoor + outdoor
149
5745
400 mW Indoor + outdoor
165
5825
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
67
Approvals for SCALANCE W788C / W786C 802.11n
2.3 National approvals
Country
Mode
Vietnam
11g 11n
CH
11a 11n
TPC
11h 11n
DFS + TPC
MHz
2412
13
2472
36
5180
5240
52
5260
TPC
5320
100
5500
5580
132
5660
200 mW Indoor only
1000 mW Indoor + outdoor
1000 mW Indoor + outdoor
140
5700
149
5745
165
200 mW Indoor only
116
100 mW Indoor + outdoor
64
Use
48
11a 11n
PWR
(EIRP)
400 mW Indoor + outdoor
5825
Approvals SCALANCE W700 802.11n
68
Reference Manual, 01/2017, C79000-G8976-C392-05
Approvals for SCALANCE W770/W730 802.11n
Note
Issued approvals on the type plate of the device
The specified approvals apply only when the corresponding mark is printed on the product.
You can check which of the following approvals have been granted for your product by the
markings on the type plate.
Range of validity
The approvals listed in this section apply to the following products:
Article number
Article number of the US
version
SCALANCE W774-1 RJ-45
6GK5774-1FX00-0AA0
6GK5774-1FX00-0AB0
SCALANCE W774-1 M12 EEC
6GK5774-1FY00-0TA0
6GK5774-1FY00-0TB0
SCALANCE W778-1 M12
6GK5778-1GY00-0AA0
6GK5778-1GY00-0AB0
SCALANCE W734-1 RJ-45
6GK5734-1FX00-0AA0
6GK5734-1FX00-0AB0
SCALANCE W738-1 M12
6GK5738-1GY00-0AA0
6GK5738-1GY00-0AB0
Access points
Client module
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
69
Approvals for SCALANCE W770/W730 802.11n
3.1 EC declaration of conformity
3.1
EC declaration of conformity
The EC Declaration of Conformity is available for all responsible authorities at:
Siemens Aktiengesellschaft
Process Industries and Drives Division,
Process Automation
DE-76181 Karlsruhe
Germany
You will find the current EC declaration of conformity for these products on the Internet
pages of Siemens Industry Online Support
(hhttps://support.industry.siemens.com/cs/ww/en/ps/15853/cert).
The SIMATIC NET products described in these Operating Instructions meet the
requirements of the following EC directives:
● 94/9/EC
Directive of the European Parliament and the Council of 23 March 1994 on the
approximation of the laws of the Member States concerning equipment and protective
systems intended for use in potentially explosive atmospheres (until 19.04.2016).
● 2014/34/EU
Directive 2014/34/EU of the European Parliament and of the Council of 26 February 2014
on the harmonization of the laws of the Member States relating to equipment and
protective systems intended for use in potentially explosive atmospheres official journal of
the EU L96, 29/03/2014, pages. 309–356 (as of 20.04.2016)
● 1999/5/EC
Directive of the European Parliament and of the Council of 1999 March 1999 on Radio
Equipment and Telecommunications Terminal Equipment and the mutual recognition of
their conformity (until 12.06.2016).
● 2014/53/EU
Directive of the European Parliament and of the Council of April 16, 2014 on the
harmonization of the laws of the member states relating to placing radio equipment on the
market.; official journal of the EU L153, 22/05/2014, pages. 62–106 (as of 13.06.2016)
● 2011/65/EU (RoHS)
RoHS directive of the European Parliament and of the Council of 8 June 2011 on the
restriction of the use of certain hazardous substances in electrical and electronic
equipment.
● 1999/519/EC
Council recommendation on the limitation of exposure of the general public to
electromagnetic fields (0 Hz to 300 GHz)
Approvals SCALANCE W700 802.11n
70
Reference Manual, 01/2017, C79000-G8976-C392-05
Approvals for SCALANCE W770/W730 802.11n
3.1 EC declaration of conformity
3.1.1
ATEX
ATEX directive (correct usage in potentially explosive atmospheres)
The SIMATIC NET product meets the requirements of the EC directive:94/9/EC (until
19.04.2016) and 2014/34/EU (as of 20.04.2016) "Equipment and Protective Devices for Use
in Potentially Explosive Atmospheres" according to the standards listed in the section
Products W770/W730 (Page 73):
Applied standard:
EN 60079-0 + A11
Hazardous areas - Part 0: Equipment - General requirements
EN 60079-15
Explosive atmospheres - Part 15: Equipment protection by type of protection "n"
3.1.2
RoHS
RoHS directive (restriction of the use of certain hazardous substances)
The SIMATIC NET products described in these operating instructions meet the requirements
of the EC directive 2011/65/EC for the restriction of the use of certain hazardous substances
in electrical and electronic equipment:
Applied standard:
EN 50581
Technical documentation for the assessment electrical and electronic products with
respect to restriction of hazardous substances
3.1.3
R&TTE / RED
3.1.3.1
Protection of health and safety
Article 3 (1) a) protection of health and safety
EN 60950-1+A1+A2+A11+A12
Information technology equipment - Safety - Part 1: General requirements
EN 62311
Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz – 300 GHz)
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
71
Approvals for SCALANCE W770/W730 802.11n
3.1 EC declaration of conformity
3.1.3.2
EMC
Art. 3 (1) b - EMC
EN 50121-3-2+AC
Railway applications - Electromagnetic compatibility - part 3-2: Railway Vehicles Devices
EN 50121-4+AC
Railway applications - Electromagnetic compatibility - part 4: Interference emissions
and immunity of signal telecommunications equipment
ETSI EN 301 489-1
Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic
compatibility for radio equipment and services - Part 1 : Common technical requirements
ETSI EN 301 489-17
10
11
12
13
3.1.3.3
Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic
compatibility for radio equipment and services - Part 17 :
EN 61000-6-1
Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for
residential, commercial and light-industrial environments
EN 61000-6-2+AC
Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for
industrial environments
EN 61000-6-3+A1+AC
Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission
standard for residential, commercial and light-industrial environments
EN 61000-6-4+A1
Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission
standard for industrial environments
Efficient use of the radio spectrum
Art. 3 (2) Efficient use of the radio spectrum
14
ETSI EN 301 328
Electromagnetic compatibility and radio spectrum matters (ERM) - wideband
transmission systems - data transmission equipment operating in the 2.4 GHz ISM
band and using wideband modulation techniques. Harmonized EN containing the
essential requirements according to Article 3.2 of the R&TTE directive.
15
ETSI EN 301 893
Broadband Radio Access Networks (BRAN) - 5 GHz high performance RLAN Harmonized EN covering essential requirements of article 3.2 of the R&TTE Directive
Approvals SCALANCE W700 802.11n
72
Reference Manual, 01/2017, C79000-G8976-C392-05
Approvals for SCALANCE W770/W730 802.11n
3.1 EC declaration of conformity
3.1.4
Products W770/W730
CE conformity
The standards that apply to the product are described in ATEX (Page 71), RoHS (Page 71)
and R&TTE / RED (Page 71)
Product name
Standards
W774-1 RJ45
1, 2 ,3, 4, 5, 8, 9, 10, 11, 12, 13, 14, 15
W734-1 RJ45
W774-1 M12 EEC
1, 2 ,3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15
W778-1 M12
3, 4, 5, 8, 9, 10, 11, 12, 13, 14, 15
W738-1 M12
Certification ID
The following table shows the product names and the corresponding certification ID:
Type
Certification ID
Article number
Article number US variant
W774-1 RJ-45
MSN-W1-RJ-E2
6GK5774-1FX00-0AA0
6GK5774-1FX00-0AB0
W774-1 M12 EEC
MSN-W1-M12-E2
6GK5774-1FY00-0TA0
6GK5774-1FY00-0TB0
W734-1 RJ-45
MSN-W1-RJ-E2
6GK5734-1FX00-0AA0
6GK5734-1FX00-0AB0
W778-1 M12
MSN65-W1-M12-E2
6GK5778-1GY00-0AA0
6GK5778-1GY00-0AB0
W738-1 M12
MSN65-W1-M12-E2
6GK5738-1GY00-0AA0
6GK5738-1GY00-0AB0
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
73
Approvals for SCALANCE W770/W730 802.11n
3.2 General approvals
3.2
General approvals
ATEX (explosion protection directive)
WARNING
When using SIMATIC NET products in hazardous area zone 2, make absolutely sure that
the associated conditions in the following document are adhered to:
"SIMATIC NET Product Information Use of subasseblies/modules in a Zone 2 Hazardous
Area".
You will find this document
on the data medium that ships with some devices.
on the Internet pages of Siemens Industry Online Support
(http://support.automation.siemens.com/ww).
Enter the document identification number C234 as the search term.
The SIMATIC NET products meet the requirements of the EC directive 94/9/EC "Equipment
and Protective Devices for Use in Potentially Explosive Atmospheres”. and as of 20.04.2016
the EC directive 2014/34/EU.
ATEX classification:
II 3 G Ex nA IIC T4 Gc
KEMA 07ATEX0145 X
The products meet the requirements of the following standards:
● EN 60079-15 (electrical apparatus for potentially explosive atmospheres; Type of
protection "n")
● EN 60079-0 (Explosive atmospheres - Part 0: Equipment - General requirements)
You will find the current versions of the standards in the currently valid ATEX certificates.
Approvals SCALANCE W700 802.11n
74
Reference Manual, 01/2017, C79000-G8976-C392-05
Approvals for SCALANCE W770/W730 802.11n
3.2 General approvals
IECEx
The SIMATIC NET products meet the requirements of explosion protection according to
IECEx.
IECEx classification:
Ex nA IIC T4 Gc
DEK 14.0025X
The products meet the requirements of the following standards:
● IEC 60079-15 (Explosive atmospheres - Part 15: Equipment protection by type of
protection "n")
● IEC 60079-0 (Explosive atmospheres - Part 0: Equipment - General requirements)
You will find the current versions of the standards in the currently valid IECEx certificates.
FM
The product meets the requirements of the standards:
● Factory Mutual Approval Standard Class Number 3611
● FM Hazardous (Classified) Location Electrical Equipment:
Non Incendive / Class I / Division 2 / Groups A,B,C,D / T4 and
Non Incendive / Class I / Zone 2 / Group IIC / T4
cULus Approval Hazardous Location
cULus Listed I. T. E. FOR HAZ. LOC.
Underwriters Laboratories Inc. complying with
● UL 60950-1 (Information Technology Equipment)
● ANSI/ISA 12.12.01-2007
● CSA C22.2 No. 213-M1987
Approved for use in
Cl. 1, Div. 2, GP A, B, C, D T4
Cl. 1, Zone 2, GP IIC T4
Report no. E240480
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
75
Approvals for SCALANCE W770/W730 802.11n
3.2 General approvals
FCC approval
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause
undesired operation.
Notice
Changes or modifications made to this equipment not expressly approved by SIEMENS may
void the FCC authorization to operate this equipment.
IEEE 802.11b or g operation of this product in the USA is firmware-limited to channels 1
through 11.
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
● Reorient or relocate the receiving antenna.
● Increase the separation between the equipment and receiver.
● Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
● Consult the dealer or an experienced radio/TV technician for help.
Notice
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance 20 cm
between the radiator and your body.
This transmitter must not be co-located or operating in conjunction with any other antenna or
transmitter. Professional Installation Notice:
To comply with FCC part 15 rules in the United States, the system must be professionally
installed to ensure compliance with the Part 15 certification. It is the responsibility of the
operator and professional installer to ensure that only certified systems are deployed in the
United States. The use of the system in any other combination (such as co-located antennas
transmitting the same information) is expressly forbidden.
Approvals SCALANCE W700 802.11n
76
Reference Manual, 01/2017, C79000-G8976-C392-05
Approvals for SCALANCE W770/W730 802.11n
3.2 General approvals
Notice
For use of DFS channels
● Use of the RCoax Cable Antenna 6XV1875-2D is not permitted in channels which
require dynamic frequency selection (DFS).
● Any installation of either a master or a client device within 35 km of a TDWR (Terminal
Doppler Weather Radar) location shall be separated by at least 30 MHz (center-to-center)
from the TDWR operating frequency.
These devices shall be registered in the industry sponsored WISPA database,
http://udia.spectrumbridge.com/udia/home.aspx
(http://udia.spectrumbridge.com/udia/home.aspx)
When you open this link, you get the following choices:
– "Search" opens a window with TDWR locations and frequencies.
– "User Signup" allows you to register as user of the database.
– After registering you can Logon and register your WLAN location. Please fill in all
required information.
For more information with respect to WISPA database and TWDR locations please consult
FCC publication KDB 443999 D01.
Notice
In order to comply with FCC/ISED/MIC RF Exposure requirements, this device must be
installed to provide at least 20 cm separation from the human body at all times.
CSA Information Technology Equipment
CSA Certification Mark
Canadian Standard Association CSA C22.2 No. 60950-1-03
RSS-247 of Industry Canada
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) this device may not cause
interference, and (2) this device must accept any interference, including interference that
may cause undesired operation of the device.
This radio transmitter (IC: 267AA-ELN1V1 for W760/W720 802.11n and IC: 267AA-MSN1V1
for W774/W734 802.11n) has been approved by Industry Canada to operate with the
antenna types listed in section 5.6 with the maximum permissible gain and required antenna
impedance for each antenna type indicated. Antenna types not included in this list, having a
gain greater than the maximum gain indicated for that type, are strictly prohibited for use with
this device.
Under Industry Canada regulations, this radio transmitter may only operate using an antenna
of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To
reduce potential radio interference to other users, the antenna type and its gain should be so
chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that
necessary for successful communication.
To reduce potential radio interference to other users, the antenna type and its gain should be
so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that
permitted for successful communication.
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
77
Approvals for SCALANCE W770/W730 802.11n
3.2 General approvals
That the device for the band 5150-5250 MHz is only for indoor usage to reduce potential for
harmful interference to co-channel mobile satellite systems.
Users should also be cautioned to take note that high power radars are allocated as primary
users (meaning they have priority) of 5250-5350 MHz and 5650-5850 MHz and these radars
could cause interference and/or damage to LE-LAN devices.
This equipment complies with IC RSS-102 radiation exposure limits set forth for an
uncontrolled environment.
In order to comply with FCC/ISED/MIC RF Exposure requirements, this device must be
installed to provide at least 20 cm separation from the human body at all times.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils
radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1)
l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout
brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le
fonctionnement.
Afin de se conformer aux exigences d'exposition RF MIC / FCC / ISED, cet appareil doit
être installé pour fournir au moins 20 cm de séparation du corps humain en tout temps
RCM
The product meets the requirements of the AS/NZS 2064 standard (Class A).
Approvals for Argentina
Devices of the SCALANCE W760/W720 series are approved in Argentina under the
following certification number:
Certification ID
Certification number
ELN-W1-RJ-E1
CNC: C-13172
Devices of the SCALANCE W770/W730 series are approved in Argentina under the
following certification numbers:
Certification ID
Certification number
MSN-W1-RJ-E2
CNC: C-13164
MSN-W1-M12-E2
CNC: C-13163
Approval for Brazil
Devices of the SCALANCE W760/W720 series are approved in Brazil under the following
certification numbers:
Este equipamento opera em caráter secundário, isto, ist é, não tem direito à proteção contra
interferência prejudicial, mesmo de estações do mesmo tipo e não pode causar interferência
a sistemas operando em caráter primário.
Approvals SCALANCE W700 802.11n
78
Reference Manual, 01/2017, C79000-G8976-C392-05
Approvals for SCALANCE W770/W730 802.11n
3.2 General approvals
Devices of the SCALANCE W770/W730 series are approved in Brazil under the following
certification numbers:
Este equipamento opera em caráter secundário, isto, ist é, não tem direito à proteção contra
interferência prejudicial, mesmo de estações do mesmo tipo e não pode causar interferência
a sistemas operando em caráter primário.
KCC Statement (Republic of Korea)
사용자안내문(제5조제1항제1호관련)
기종별
A 급 기기급 기기
(업무용 방송통신기기)
사용자안내문
이 기기는 업무용(A 급)으로 전자파적합등록을 한(A 급)으로
전자파적합등록을 한
기기이오니 판매자 또는 사용자는 이 점을
주의하시기 바라며, 가정외의 지역에서 사용하는
것을 목적으로 합니다.
"당해 무선설비는 전파혼신 가능성이 있으므로 인명안전과 관련된 서비스는 할 수 없음"
Marking for the customs union
EAC (Eurasian Conformity)
Customs union of Russia, Belarus and Kazakhstan
Declaration of the conformity according to the technical regulations of the customs union
(TR CU)
Railway approval for the SCALANCE W774-1 M12 EEC
The SCALANCE W774-1 M12 EEC device meets the requirements of the railway standard
EN 50155:2007 "Railway Applications - Electronic equipment used on rolling stock".
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
79
Approvals for SCALANCE W770/W730 802.11n
3.3 SCALANCE W774/734 national approvals
3.3
SCALANCE W774/734 national approvals
The following table lists the countries in which the SCALANCE W700 product is approved.
The diamond symbol (♦) identifies all countries for which there was no approval at the time
these operating instructions were written.
The current status of the approvals can be found on the Internet at the following address:
http://www.siemens.com/funkzulassungen
Column
Meaning
Country
Country
Mode
IEEE 802.11 standard and the TPC and / or DFS functionality, where required
CH
Channel
MHz
Frequency
PWR (EIRP)
Maximum permitted effective isotropic radiated power
Use
Permitted use indoors and / or outdoors
Approvals SCALANCE W700 802.11n
80
Reference Manual, 01/2017, C79000-G8976-C392-05
Approvals for SCALANCE W770/W730 802.11n
3.3 SCALANCE W774/734 national approvals
Country
Mode
Andorra
Belgium
Bosnia and Herzegovina
Bulgaria
Denmark
Germany
Estonia
Finland
France
Greece
Great Britain
Ireland
Iceland
Italy
Croatia
Latvia
Liechtenstein
Lithuania
Luxembourg
Malta
Macedonia
Monaco
Montenegro
Netherlands
Norway
Austria
Poland
Portugal
Romania
San Marino
Sweden
Switzerland
Slovakia
Slovenia
Spain
Czech Republic
Turkey
Hungary
Vatican
Cyprus
11g 11n
Egypt
CH
MHz
PWR
(EIRP)
Use
13
2412
2472
100 mW Indoor + outdoor
36
48
5180
5240
200 mW Indoor only
TPC
52
64
5260
5320
200 mW Indoor only
DFS + TPC
100
116
5500
5580
1000 mW Indoor + outdoor
132
140
5660
5700
1000 mW Indoor + outdoor
11a 11n
149
165
5745
5825
25 mW Indoor + outdoor
11g 11n
2412
100 mW Indoor + outdoor
11a 11n
11a 11n
11a 11n
TPC
13
2472
36
5180
64
200 mW Indoor only
5320
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
81
Approvals for SCALANCE W770/W730 802.11n
3.3 SCALANCE W774/734 national approvals
Country
Mode
Angola
11g 11n
CH
11a 11n
TPC
11a 11n
DFS + TPC
MHz
2412
13
2472
36
5180
5240
52
5260
11g 11n
11a 11n
5320
100
5500
11a 11n
TPC
5580
132
5660
5700
2412
13
2472
36
5180
5240
52
5260
11a 11n
5320
100
5500
5600
132
5660
50 mW Indoor + outdoor
250 mW Indoor + outdoor
250 mW Indoor + outdoor
250 mW Indoor + outdoor
140
5700
149
5745
165
1000 mW Indoor + outdoor
120
1000 mW Indoor + outdoor
64
1000 mW Indoor + outdoor
48
200 mW Indoor only
140
200 mW Indoor only
116
100 mW Indoor + outdoor
64
Use
48
Argentina
PWR
(EIRP)
1000 mW Indoor + outdoor
5825
Approvals SCALANCE W700 802.11n
82
Reference Manual, 01/2017, C79000-G8976-C392-05
Approvals for SCALANCE W770/W730 802.11n
3.3 SCALANCE W774/734 national approvals
Country
Mode
Australia
11g 11n
CH
New Zealand
11a 11n
MHz
2412
13
2472
36
5180
11a 11n
DFS + TPC
11a 11n
5240
52
5260
11g 11n
11a 11n
5320
149
5745
11a 11n
DFS + TPC
5825
2412
11a 11n
2472
36
5180
Belarus
11g 11n
11a 11n
TCP
48
5240
5260
11a 11n
TCP + DFS
5320
149
5745
5825
2412
13
2472
36
5180
5240
52
5260
2000 mW Indoor + outdoor
100 mW Indoor + outdoor
100 mW Indoor + outdoor
100 mW Indoor + outdoor
64
5320
132
5660
140
200 mW Indoor only
48
200 mW Indoor only
165
100 mW Indoor + outdoor
64
400 mW Indoor + outdoor
52
200 mW Indoor only
13
200 mW Indoor only
165
100 mW Indoor + outdoor
64
Use
48
Bahrain
PWR
(EIRP)
100 mW Indoor + outdoor
5700
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
83
Approvals for SCALANCE W770/W730 802.11n
3.3 SCALANCE W774/734 national approvals
Country
Mode
Brazil
11g 11n
CH
11a 11n
MHz
2412
13
2472
36
5180
11a 11n
TPC
5240
52
5260
Chile
11g 11n
11a 11n
TPC
5320
100
5500
11a 11n
DFS + TPC
5700
149
5745
11a 11n
DFS
China
11g 11n
5825
2412
13
2472
36
5180
5240
52
5260
11a 11n
TPC
5320
149
5745
11a 11n
DFS + TPC
5825
2412
11a 11n
2472
36
5180
5240
52
5260
100 mW Indoor only
100 mW Indoor + outdoor
200 mW Indoor only
200 mW Indoor only
64
5320
149
5745
100 mW Indoor only
48
165
100 mW Indoor only
13
100 mW Indoor only
165
4000 mW Indoor + outdoor
64
1000 mW Indoor + outdoor
48
200 mW Indoor only
165
200 mW Indoor only
140
4000 mW Indoor + outdoor
64
Use
48
11a 11n
PWR
(EIRP)
2000 mW Indoor + outdoor
5825
Approvals SCALANCE W700 802.11n
84
Reference Manual, 01/2017, C79000-G8976-C392-05
Approvals for SCALANCE W770/W730 802.11n
3.3 SCALANCE W774/734 national approvals
Country
Mode
Ivory Coast
11g 11n
CH
11a 11n
TPC
11a 11n
DFS + TPC
MHz
2412
13
2472
36
5180
5240
52
5260
11g 11n
11a 11n
5320
100
5500
DFS + TPC
5580
132
5660
200 mW Indoor only
1000 mW Indoor + outdoor
1000 mW Indoor + outdoor
140
5700
2412
100 mW Indoor + outdoor
2417
200 mW Indoor + outdoor
10
2457
11
2462
100 mW Indoor + outdoor
36
5180
200 mW Indoor only
48
5240
52
5260
5320
100
5500
400 mW Indoor + outdoor
116
5580
132
5660
400 mW Indoor + outdoor
64
Hong Kong
200 mW Indoor only
116
11a 11n
100 mW Indoor + outdoor
64
Use
48
Guatemala
PWR
(EIRP)
400 mW Indoor + outdoor
140
5700
11a 11n
149
165
5745
5825
400 mW Indoor + outdoor
11g 11n
2412
100 mW Indoor + outdoor
11a 11n
TPC
13
2472
36
5180
48
200 mW Indoor only
5240
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
85
Approvals for SCALANCE W770/W730 802.11n
3.3 SCALANCE W774/734 national approvals
Country
Mode
CH
11a 11n
MHz
52
DFS + TPC
11a 11n
TPC
5320
5500
11a 11n
DFS + TPC
5580
132
5660
11a 11n
5700
2412
13
2472
36
5180
Indonesia
11g 11n
11a 11n
5240
52
5260
64
5320
5745
200 mW Indoor only
200 mW Indoor only
200 mW Indoor + outdoor
165
5825
2412
13
2472
149
5745
161
100 mW Indoor + outdoor
149
1000 mW Indoor + outdoor
48
1000 mW Indoor + outdoor
140
200 mW Indoor only
116
Use
64
11g 11n
5260
100
India
PWR
(EIRP)
100 mW Indoor + outdoor
400 mW Indoor + outdoor
5805
Approvals SCALANCE W700 802.11n
86
Reference Manual, 01/2017, C79000-G8976-C392-05
Approvals for SCALANCE W770/W730 802.11n
3.3 SCALANCE W774/734 national approvals
Country
Mode
Japan
11g 11n
CH
MHz
2412
2472
16
5040
5080
200 mW Indoor + outdoor
11a 11n
36
5180
200 mW Indoor only
DFS + TPC
11a
11g 11n
5240
52
5260
TPC
11a 11n
DFS + TPC
5320
100
5500
200 mW Indoor + outdoor
140
5700
184
196
4920
4980
200 mW Indoor + outdoor
2412
100 mW Indoor + outdoor
13
2472
36
5180
5240
52
5260
100 mW Indoor only
48
100 mW Indoor only
64
5320
132
5660
11g 11n
200 mW Indoor only
64
11a 11n
48
Colombia
200 mW Indoor + outdoor
13
11a 11n
Qatar
Use
11a
Kazakhstan
PWR
(EIRP)
100 mW Indoor + outdoor
140
5700
2412
100 mW Indoor only
13
2472
11a 11n
149
165
5745
5825
100 mW Indoor only
11g 11n
2412
100 mW Indoor + outdoor
11a 11n
11
2462
36
5180
48
200 mW Indoor only
5240
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
87
Approvals for SCALANCE W770/W730 802.11n
3.3 SCALANCE W774/734 national approvals
Country
Mode
CH
11a 11n
MHz
52
DFS + TPC
5320
5500
11g 11n
5580
132
5660
11a 11n
TPC
5700
149
5745
Kuwait
11g 11n
5825
2412
11a 11n
TPC
2472
149
5745
11a 11n
DFS + TPC
5805
2412
Macau
Madagascar
400 mW Indoor + outdoor
100 mW Indoor + outdoor
13
2472
36
5180
200 mW Indoor + outdoor
48
5240
52
5260
400 mW Indoor + outdoor
161
400 mW Indoor + outdoor
13
400 mW Indoor + outdoor
165
400 mW Indoor + outdoor
140
400 mW Indoor + outdoor
116
Use
64
Korea
5260
100
11a 11n
PWR
(EIRP)
200 mW Indoor + outdoor
64
5320
11g 11n
13
2412
2472
100 mW Indoor + outdoor
11a 11n
149
161
5745
5805
100 mW Indoor + outdoor
11g 11n
13
2412
2472
100 mW Indoor + outdoor
36
48
5180
5240
200 mW Indoor only
TPC
52
64
5260
5320
200 mW Indoor only
DFS + TPC
11a 11n
11a 11n
Approvals SCALANCE W700 802.11n
88
Reference Manual, 01/2017, C79000-G8976-C392-05
Approvals for SCALANCE W770/W730 802.11n
3.3 SCALANCE W774/734 national approvals
Country
Mode
CH
MHz
100
11g 11n
11a 11n
DFS
5580
5660
11a 11n
5700
149
5745
Mexico
11g 11n
5825
2412
13
2472
56
5280
11a 11n
5320
149
5745
5825
2412
Pakistan
11g 11n
2462
36
5180
11a 11n
5320
149
5745
5825
2412
1000 mW Indoor + outdoor
1000 mW Indoor + outdoor
100 mW Indoor + outdoor
13
2472
149
5745
165
500 mW Indoor + outdoor
165
1000 mW Indoor + outdoor
64
200 mW Indoor only
11
200 mW Indoor + outdoor
165
400 mW Indoor + outdoor
64
1000 mW Indoor + outdoor
165
1000 mW Indoor + outdoor
140
Use
132
Malaysia
5500
116
11a 11n
PWR
(EIRP)
100 mW Indoor + outdoor
5825
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
89
Approvals for SCALANCE W770/W730 802.11n
3.3 SCALANCE W774/734 national approvals
Country
Mode
Russia
11g 11n
CH
11a 11n
TPC
11a 11n
DFS + TPC
MHz
2412
13
2472
36
5180
5240
52
5260
11g 11n
11a 11n
TPC
5320
132
5660
11a 11n
DFS + TPC
5700
2412
2472
36
5180
5240
52
5260
Serbia
100 mW Indoor + outdoor
200 mW Indoor only
200 mW Indoor only
64
5320
100
5500
1000 mW Indoor + outdoor
116
5580
132
5660
100 mW Indoor + outdoor
48
100 mW Indoor + outdoor
13
100 mW Indoor + outdoor
140
100 mW Indoor + outdoor
64
Use
48
Saudi Arabia
PWR
(EIRP)
1000 mW Indoor + outdoor
140
5700
11g 11n
13
2412
2472
100 mW Indoor + outdoor
11a 11n
5180
5240
200 mW Indoor only
TPC
36
48
52
64
5260
5320
200 mW Indoor only
DFS + TPC
100
116
5500
5580
1000 mW Indoor + outdoor
132
140
5660
5700
1000 mW Indoor + outdoor
11a 11n
Approvals SCALANCE W700 802.11n
90
Reference Manual, 01/2017, C79000-G8976-C392-05
Approvals for SCALANCE W770/W730 802.11n
3.3 SCALANCE W774/734 national approvals
Country
Mode
South Africa
11g 11n
CH
PWR
(EIRP)
Use
13
2412
2472
100 mW Indoor + outdoor
36
48
5180
5240
200 mW Indoor only
TPC
52
64
5260
5320
200 mW Indoor only
DFS + TPC
100
116
5500
5580
1000 mW Indoor + outdoor
132
140
5660
5700
1000 mW Indoor + outdoor
2412
100 mW Indoor + outdoor
11a 11n
11a 11n
Singapore
MHz
11g 11n
Philippines
11a 11n
TPC
11a 11n
DFS + TPC
11a 11n
13
2472
36
5180
48
5240
52
5260
200 mW Indoor + outdoor
200 mW Indoor + outdoor
64
5320
100
116
5500
5580
1000 mW Indoor + outdoor
132
140
5660
5700
1000 mW Indoor + outdoor
149
5745
1000 mW Indoor + outdoor
165
5825
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
91
Approvals for SCALANCE W770/W730 802.11n
3.3 SCALANCE W774/734 national approvals
Country
Mode
Taiwan
11g 11n
CH
11a 11n
DFS + TPC
11a 11n
MHz
11g 11n
2412
100 mW Indoor + outdoor
2417
200 mW Indoor + outdoor
10
2457
11
2462
100 mW Indoor + outdoor
52
5260
400 mW Indoor + outdoor
64
5320
5500
5580
400 mW Indoor + outdoor
132
140
5660
5700
400 mW Indoor + outdoor
149
5745
400 mW Indoor + outdoor
DFS
11a 11n
165
5825
2412
2472
36
5180
5240
52
5260
5320
149
5745
1000 mW Indoor only
64
165
200 mW Indoor only
48
1000 mW Indoor + outdoor
13
11a 11n
100
116
11a 11n
Use
Venezuela
PWR
(EIRP)
4000 mW Indoor + outdoor
5825
Approvals SCALANCE W700 802.11n
92
Reference Manual, 01/2017, C79000-G8976-C392-05
Approvals for SCALANCE W770/W730 802.11n
3.3 SCALANCE W774/734 national approvals
Country
Mode
United Arab Emirates
11g 11n
CH
11a 11n
TPC
11a 11n
DFS + TPC
MHz
2412
13
2472
36
5180
5240
52
5260
11g 11n
Canada
Colombia
Peru
11a 11n
Puerto Rico
5320
100
5500
USA
Uruguay
11a 11n
DFS + TPC
5580
132
5660
11a 11n
200 mW Indoor only
1000 mW Indoor only
1000 mW Indoor only
140
5700
2412
11
2462
36
5180
100 mW Indoor + outdoor
200 mW Indoor only
48
5240
52
5260
200 mW Indoor only
116
Thailand
100 mW Indoor + outdoor
64
Use
48
Bahamas
PWR
(EIRP)
400 mW Indoor + outdoor
64
5320
100
116
5500
5580
400 mW Indoor + outdoor
132
140
5660
5700
400 mW Indoor + outdoor
149
5745
400 mW Indoor + outdoor
165
5825
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
93
Approvals for SCALANCE W770/W730 802.11n
3.3 SCALANCE W774/734 national approvals
Country
Mode
Vietnam
11g 11n
CH
11a 11n
TPC
11a 11n
DFS + TPC
MHz
2412
13
2472
36
5180
5240
52
5260
5320
100
5500
5580
132
5660
200 mW Indoor only
1000 mW Indoor + outdoor
1000 mW Indoor + outdoor
140
5700
149
5745
165
200 mW Indoor only
116
100 mW Indoor + outdoor
64
Use
48
11a 11n
PWR
(EIRP)
400 mW Indoor + outdoor
5825
Approvals SCALANCE W700 802.11n
94
Reference Manual, 01/2017, C79000-G8976-C392-05
Approvals for SCALANCE W770/W730 802.11n
3.4 SCALANCE W778/738 national approvals
3.4
SCALANCE W778/738 national approvals
The following table lists the countries in which the SCALANCE W700 product is approved.
The diamond symbol (♦) identifies all countries for which there was no approval at the time
these operating instructions were written.
The current status of the approvals can be found on the Internet at the following address:
http://www.siemens.com/funkzulassungen
Column
Meaning
Country
Country
Mode
IEEE 802.11 standard and the TPC and / or DFS functionality, where required
CH
Channel
MHz
Frequency
PWR (EIRP)
Maximum permitted effective isotropic radiated power
Use
Permitted use indoors and / or outdoors
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
95
Approvals for SCALANCE W770/W730 802.11n
3.4 SCALANCE W778/738 national approvals
Country
Mode
Andorra
Belgium
Bosnia and Herzegovina
Bulgaria
Denmark
Germany
Estonia
Finland
France
Greece
Great Britain
Ireland
Iceland
Italy
Croatia
Latvia
Liechtenstein
Lithuania
Luxembourg
Malta
Macedonia
Monaco
Montenegro
Netherlands
Norway
Austria
Poland
Portugal
Romania
San Marino
Sweden
Switzerland
Serbia ♦
Slovakia
Slovenia
Spain
Czech Republic
Turkey
Hungary
Vatican
Cyprus
11g 11n
CH
MHz
PWR
(EIRP)
Use
13
2412
2472
100 mW Indoor + outdoor
36
48
5180
5240
200 mW Indoor only
TPC
52
64
5260
5320
200 mW Indoor only
DFS + TPC
100
116
5500
5580
1000 mW Indoor + outdoor
132
140
5660
5700
1000 mW Indoor + outdoor
149
165
5745
5825
25 mW Indoor + outdoor
11a 11n
11a 11n
11a 11n
Approvals SCALANCE W700 802.11n
96
Reference Manual, 01/2017, C79000-G8976-C392-05
Approvals for SCALANCE W770/W730 802.11n
3.4 SCALANCE W778/738 national approvals
Country
Mode
Egypt ♦
11g 11n
CH
11a 11n
TPC
Australia ♦
11g 11n
New Zealand ♦
11a 11n
MHz
2412
13
2472
36
5180
DFS + TPC
5320
2412
13
2472
36
5180
11a 11n
48
5240
5260
Bahrain ♦
11g 11n
5320
149
5745
11a 11n
5825
2412
11a 11n
DFS + TPC
2472
36
5180
11a 11n
5240
52
5260
64
5320
5745
400 mW Indoor + outdoor
100 mW Indoor + outdoor
200 mW Indoor only
200 mW Indoor only
149
165
200 mW Indoor only
48
200 mW Indoor only
13
100 mW Indoor + outdoor
165
200 mW Indoor only
64
100 mW Indoor + outdoor
52
Use
64
11a 11n
PWR
(EIRP)
2000 mW Indoor + outdoor
5825
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
97
Approvals for SCALANCE W770/W730 802.11n
3.4 SCALANCE W778/738 national approvals
Country
Mode
Brazil ♦
11g 11n
CH
11a 11n
MHz
2412
13
2472
36
5180
11a 11n
TPC
5240
52
5260
Chile ♦
11g 11n
11a 11n
TPC
5320
100
5500
11a 11n
DFS + TPC
5700
149
5745
11a 11n
DFS
China ♦
11g 11n
5825
2412
13
2472
36
5180
5240
52
5260
11a 11n
TPC
5320
149
5745
11a 11n
DFS + TPC
5825
2412
11a 11n
2472
36
5180
5240
52
5260
100 mW Indoor only
100 mW Indoor + outdoor
200 mW Indoor only
200 mW Indoor only
64
5320
149
5745
100 mW Indoor only
48
165
100 mW Indoor only
13
100 mW Indoor only
165
4000 mW Indoor + outdoor
64
1000 mW Indoor + outdoor
48
200 mW Indoor only
165
200 mW Indoor only
140
4000 mW Indoor + outdoor
64
Use
48
11a 11n
PWR
(EIRP)
2000 mW Indoor + outdoor
5825
Approvals SCALANCE W700 802.11n
98
Reference Manual, 01/2017, C79000-G8976-C392-05
Approvals for SCALANCE W770/W730 802.11n
3.4 SCALANCE W778/738 national approvals
Country
Mode
India ♦
11g 11n
CH
11a 11n
TPC
11a 11n
DFS + TPC
11a 11n
MHz
2412
13
2472
36
5180
5240
52
5260
11g 11n
11a 11n
5320
149
5745
Japan ♦
11g 11n
5825
2412
2472
149
5745
200 mW Indoor + outdoor
100 mW Indoor + outdoor
400 mW Indoor + outdoor
161
5805
2412
200 mW Indoor + outdoor
13
2472
11a
16
5040
5080
200 mW Indoor + outdoor
11a 11n
36
5180
200 mW Indoor only
11a 11n
DFS + TPC
11a
11g 11n
5240
52
5260
TPC
200 mW Indoor only
64
5320
100
5500
200 mW Indoor + outdoor
140
5700
184
196
4920
4980
200 mW Indoor + outdoor
2412
400 mW Indoor + outdoor
11a 11n
48
Korea ♦
200 mW Indoor only
13
200 mW Indoor only
165
100 mW Indoor + outdoor
64
Use
48
Indonesia ♦
PWR
(EIRP)
13
2472
149
5745
161
400 mW Indoor + outdoor
5805
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
99
Approvals for SCALANCE W770/W730 802.11n
3.4 SCALANCE W778/738 national approvals
Country
Mode
Kuwait ♦
11g 11n
CH
11a 11n
TPC
11a 11n
DFS + TPC
Mexico ♦
11g 11n
11a 11n
MHz
2412
13
2472
36
5180
5240
52
5260
100 mW Indoor + outdoor
200 mW Indoor + outdoor
200 mW Indoor + outdoor
64
5320
2412
11
2462
36
5180
500 mW Indoor + outdoor
1000 mW Indoor + outdoor
64
5320
149
5745
Use
48
South Africa ♦
PWR
(EIRP)
1000 mW Indoor + outdoor
165
5825
13
2412
2472
100 mW Indoor + outdoor
36
48
5180
5240
200 mW Indoor only
TPC
52
64
5260
5320
200 mW Indoor only
DFS + TPC
100
116
5500
5580
1000 mW Indoor + outdoor
132
140
5660
5700
1000 mW Indoor + outdoor
11g 11n
11a 11n
11a 11n
Approvals SCALANCE W700 802.11n
100
Reference Manual, 01/2017, C79000-G8976-C392-05
Approvals for SCALANCE W770/W730 802.11n
3.4 SCALANCE W778/738 national approvals
Country
Mode
Singapore ♦
11g 11n
CH
11a 11n
TPC
11a 11n
DFS + TPC
11a 11n
MHz
2412
13
2472
36
5180
5240
52
5260
11g 11n
11a 11n
DFS + TPC
11a 11n
11g 11n
Peru ♦
Thailand ♦
USA ♦
11a 11n
DFS + TPC
200 mW Indoor + outdoor
200 mW Indoor + outdoor
5320
100
116
5500
5580
1000 mW Indoor + outdoor
132
140
5660
5700
1000 mW Indoor + outdoor
149
5745
1000 mW Indoor + outdoor
165
5825
2412
100 mW Indoor + outdoor
2417
200 mW Indoor + outdoor
10
2457
11
2462
100 mW Indoor + outdoor
52
5260
400 mW Indoor + outdoor
64
5320
100
116
5500
5580
400 mW Indoor + outdoor
132
140
5660
5700
400 mW Indoor + outdoor
149
5745
400 mW Indoor + outdoor
165
5825
2412
11
2462
36
5180
11a 11n
100 mW Indoor + outdoor
64
Canada ♦
Use
48
Taiwan ♦
PWR
(EIRP)
48
5240
5260
200 mW Indoor only
52
64
100 mW Indoor + outdoor
400 mW Indoor + outdoor
5320
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
101
Approvals for SCALANCE W770/W730 802.11n
3.4 SCALANCE W778/738 national approvals
Country
Mode
11a 11n
CH
MHz
PWR
(EIRP)
Use
100
116
5500
5580
400 mW Indoor + outdoor
132
140
5660
5700
400 mW Indoor + outdoor
149
5745
400 mW Indoor + outdoor
165
5825
Approvals SCALANCE W700 802.11n
102
Reference Manual, 01/2017, C79000-G8976-C392-05
4
Approvals for SCALANCE W760/W720 802.11n
Note
Issued approvals on the type plate of the device
The specified approvals apply only when the corresponding mark is printed on the product.
You can check which of the following approvals have been granted for your product by the
markings on the type plate.
Range of validity
The approvals listed in this section apply to the following products:
Article number
Article number of the
US version
Article number of
the Israel version
6GK5761-1FC000AA0
6GK5761-1FC000AB0
SCALANCE W722-1 RJ45
(iFeatures)
6GK5722-1FC000AA0
6GK5722-1FC000AB0
6GK5722-1FC00-0AC0
SCALANCE W721-1 RJ45
6GK5721-1FC000AA0
6GK5721-1FC000AB0
Access point
SCALANCE W761-1 RJ45
Ethernet client modules
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
103
Approvals for SCALANCE W760/W720 802.11n
4.1 EC declaration of conformity
4.1
EC declaration of conformity
The EC Declaration of Conformity is available for all responsible authorities at:
Siemens Aktiengesellschaft
Process Industries and Drives Division,
Process Automation
DE-76181 Karlsruhe
Germany
You will find the current EC declaration of conformity for these products on the Internet
pages of Siemens Industry Online Support
(hhttps://support.industry.siemens.com/cs/ww/en/ps/15853/cert).
The SIMATIC NET products described in these Operating Instructions meet the
requirements of the following EC directives:
● 94/9/EC
Directive of the European Parliament and the Council of 23 March 1994 on the
approximation of the laws of the Member States concerning equipment and protective
systems intended for use in potentially explosive atmospheres (until 19.04.2016).
● 2014/34/EU
Directive 2014/34/EU of the European Parliament and of the Council of 26 February 2014
on the harmonization of the laws of the Member States relating to equipment and
protective systems intended for use in potentially explosive atmospheres official journal of
the EU L96, 29/03/2014, pages. 309–356 (as of 20.04.2016)
● 1999/5/EC
Directive of the European Parliament and of the Council of 1999 March 1999 on Radio
Equipment and Telecommunications Terminal Equipment and the mutual recognition of
their conformity (until 12.06.2016).
● 2014/53/EU
Directive of the European Parliament and of the Council of April 16, 2014 on the
harmonization of the laws of the member states relating to placing radio equipment on the
market.; official journal of the EU L153, 22/05/2014, pages. 62–106 (as of 13.06.2016)
● 2011/65/EU (RoHS)
RoHS directive of the European Parliament and of the Council of 8 June 2011 on the
restriction of the use of certain hazardous substances in electrical and electronic
equipment.
● 1999/519/EC
Council recommendation on the limitation of exposure of the general public to
electromagnetic fields (0 Hz to 300 GHz)
Approvals SCALANCE W700 802.11n
104
Reference Manual, 01/2017, C79000-G8976-C392-05
Approvals for SCALANCE W760/W720 802.11n
4.1 EC declaration of conformity
4.1.1
ATEX
ATEX directive (correct usage in potentially explosive atmospheres)
The SIMATIC NET product meets the requirements of the EC directive:94/9/EC (until
19.04.2016) and 2014/34/EU (as of 20.04.2016) "Equipment and Protective Devices for Use
in Potentially Explosive Atmospheres" according to the standards listed in the section
AUTOHOTSPOT:
Applied standard:
EN 60079-0 + A11
Hazardous areas - Part 0: Equipment - General requirements
EN 60079-15
Explosive atmospheres - Part 15: Equipment protection by type of protection "n"
4.1.2
RoHS
RoHS directive (restriction of the use of certain hazardous substances)
The SIMATIC NET products described in these operating instructions meet the requirements
of the EC directive 2011/65/EC for the restriction of the use of certain hazardous substances
in electrical and electronic equipment:
Applied standard:
EN 50581
Technical documentation for the assessment electrical and electronic products with
respect to restriction of hazardous substances
4.1.3
R&TTE / RED
4.1.3.1
Protection of health and safety
Article 3 (1) a) protection of health and safety
EN 60950-1+A1+A2+A11+A12
Information technology equipment - Safety - Part 1: General requirements
EN 62311
Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz – 300 GHz)
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
105
Approvals for SCALANCE W760/W720 802.11n
4.1 EC declaration of conformity
4.1.3.2
EMC
Art. 3 (1) b - EMC
EN 50121-3-2+AC
Railway applications - Electromagnetic compatibility - part 3-2: Railway Vehicles Devices
EN 50121-4+AC
Railway applications - Electromagnetic compatibility - part 4: Interference emissions
and immunity of signal telecommunications equipment
ETSI EN 301 489-1
Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic
compatibility for radio equipment and services - Part 1 : Common technical requirements
ETSI EN 301 489-17
10
11
12
13
4.1.3.3
Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic
compatibility for radio equipment and services - Part 17 :
EN 61000-6-1
Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for
residential, commercial and light-industrial environments
EN 61000-6-2+AC
Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for
industrial environments
EN 61000-6-3+A1+AC
Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission
standard for residential, commercial and light-industrial environments
EN 61000-6-4+A1
Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission
standard for industrial environments
Efficient use of the radio spectrum
Art. 3 (2) Efficient use of the radio spectrum
14
ETSI EN 301 328
Electromagnetic compatibility and radio spectrum matters (ERM) - wideband
transmission systems - data transmission equipment operating in the 2.4 GHz ISM
band and using wideband modulation techniques. Harmonized EN containing the
essential requirements according to Article 3.2 of the R&TTE directive.
15
ETSI EN 301 893
Broadband Radio Access Networks (BRAN) - 5 GHz high performance RLAN Harmonized EN covering essential requirements of article 3.2 of the R&TTE Directive
Approvals SCALANCE W700 802.11n
106
Reference Manual, 01/2017, C79000-G8976-C392-05
Approvals for SCALANCE W760/W720 802.11n
4.1 EC declaration of conformity
4.1.4
Products
CE conformity
The standards that apply to the product are described in RoHS (Page 105), ATEX
(Page 105) and R&TTE / RED (Page 105).
Product name
Standards
W761-1 RJ45
W722-1 RJ45
W721-1 RJ45
1, 2 3, 4, 5, 8, 9, 10, 11, 12, 13, 14, 15
W774-1 RJ45
W734-1 RJ45
W774-1 M12 EEC
1, 2 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15
Certification ID
The following table shows the product names and the corresponding certification ID:
Type
Certification ID
Order number
Order number US variant
W761-1 RJ-45
ELN-W1-RJ-E1
6GK5761-1FC00-0AA0
6GK5761-1FC00-0AB0
W722-1 RJ-45
ELN-W1-RJ-E1
6GK5722-1FC00-0AA0
6GK5722-1FC00-0AB0
W721-1 RJ-45
ELN-W1-RJ-E1
6GK5721-1FC00-0AA0
6GK5721-1FC00-0AB0
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
107
Approvals for SCALANCE W760/W720 802.11n
4.2 General approvals
4.2
General approvals
ATEX (explosion protection directive)
WARNING
When using SIMATIC NET products in hazardous area zone 2, make absolutely sure that
the associated conditions in the following document are adhered to:
"SIMATIC NET Product Information Use of subasseblies/modules in a Zone 2 Hazardous
Area".
You will find this document
on the data medium that ships with some devices.
on the Internet pages of Siemens Industry Online Support
(http://support.automation.siemens.com/ww).
Enter the document identification number C234 as the search term.
The SIMATIC NET products meet the requirements of the EC directive 94/9/EC "Equipment
and Protective Devices for Use in Potentially Explosive Atmospheres”. and as of 20.04.2016
the EC directive 2014/34/EU.
ATEX classification:
II 3 G Ex nA IIC T4 Gc
KEMA 07ATEX0145 X
The products meet the requirements of the following standards:
● EN 60079-15 (electrical apparatus for potentially explosive atmospheres; Type of
protection "n")
● EN 60079-0 (Explosive atmospheres - Part 0: Equipment - General requirements)
You will find the current versions of the standards in the currently valid ATEX certificates.
IECEx
The SIMATIC NET products meet the requirements of explosion protection according to
IECEx.
IECEx classification:
Ex nA IIC T4 Gc
DEK 14.0025X
The products meet the requirements of the following standards:
● IEC 60079-15 (Explosive atmospheres - Part 15: Equipment protection by type of
protection "n")
● IEC 60079-0 (Explosive atmospheres - Part 0: Equipment - General requirements)
You will find the current versions of the standards in the currently valid IECEx certificates.
Approvals SCALANCE W700 802.11n
108
Reference Manual, 01/2017, C79000-G8976-C392-05
Approvals for SCALANCE W760/W720 802.11n
4.2 General approvals
FM
The product meets the requirements of the standards:
● Factory Mutual Approval Standard Class Number 3611
● FM Hazardous (Classified) Location Electrical Equipment:
Non Incendive / Class I / Division 2 / Groups A,B,C,D / T4 and
Non Incendive / Class I / Zone 2 / Group IIC / T4
cULus Approval Hazardous Location
cULus Listed I. T. E. FOR HAZ. LOC.
Underwriters Laboratories Inc. complying with
● UL 60950-1 (Information Technology Equipment)
● ANSI/ISA 12.12.01-2007
● CSA C22.2 No. 213-M1987
Approved for use in
Cl. 1, Div. 2, GP A, B, C, D T4
Cl. 1, Zone 2, GP IIC T4
Report no. E240480
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
109
Approvals for SCALANCE W760/W720 802.11n
4.2 General approvals
FCC approval
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause
undesired operation.
Notice
Changes or modifications made to this equipment not expressly approved by SIEMENS may
void the FCC authorization to operate this equipment.
IEEE 802.11b or g operation of this product in the USA is firmware-limited to channels 1
through 11.
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
● Reorient or relocate the receiving antenna.
● Increase the separation between the equipment and receiver.
● Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
● Consult the dealer or an experienced radio/TV technician for help.
Notice
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance 20 cm
between the radiator and your body.
This transmitter must not be co-located or operating in conjunction with any other antenna or
transmitter. Professional Installation Notice:
To comply with FCC part 15 rules in the United States, the system must be professionally
installed to ensure compliance with the Part 15 certification. It is the responsibility of the
operator and professional installer to ensure that only certified systems are deployed in the
United States. The use of the system in any other combination (such as co-located antennas
transmitting the same information) is expressly forbidden.
Approvals SCALANCE W700 802.11n
110
Reference Manual, 01/2017, C79000-G8976-C392-05
Approvals for SCALANCE W760/W720 802.11n
4.2 General approvals
Notice
For use of DFS channels
● Use of the RCoax Cable Antenna 6XV1875-2D is not permitted in channels which
require dynamic frequency selection (DFS).
● Any installation of either a master or a client device within 35 km of a TDWR (Terminal
Doppler Weather Radar) location shall be separated by at least 30 MHz (center-to-center)
from the TDWR operating frequency.
These devices shall be registered in the industry sponsored WISPA database,
http://udia.spectrumbridge.com/udia/home.aspx
(http://udia.spectrumbridge.com/udia/home.aspx)
When you open this link, you get the following choices:
– "Search" opens a window with TDWR locations and frequencies.
– "User Signup" allows you to register as user of the database.
– After registering you can Logon and register your WLAN location. Please fill in all
required information.
For more information with respect to WISPA database and TWDR locations please consult
FCC publication KDB 443999 D01.
CSA Information Technology Equipment
CSA Certification Mark
Canadian Standard Association CSA C22.2 No. 60950-1-03
RSS-247 of Industry Canada
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) this device may not cause
interference, and (2) this device must accept any interference, including interference that
may cause undesired operation of the device.
This radio transmitter (IC: 267AA-ELN1V1 for W760/W720 802.11n and IC: 267AA-MSN1V1
for W774/W734 802.11n) has been approved by Industry Canada to operate with the
antenna types listed in section 5.6 with the maximum permissible gain and required antenna
impedance for each antenna type indicated. Antenna types not included in this list, having a
gain greater than the maximum gain indicated for that type, are strictly prohibited for use with
this device.
Under Industry Canada regulations, this radio transmitter may only operate using an antenna
of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To
reduce potential radio interference to other users, the antenna type and its gain should be so
chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that
necessary for successful communication.
To reduce potential radio interference to other users, the antenna type and its gain should be
so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that
permitted for successful communication.
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
111
Approvals for SCALANCE W760/W720 802.11n
4.2 General approvals
That the device for the band 5150-5250 MHz is only for indoor usage to reduce potential for
harmful interference to co-channel mobile satellite systems.
Users should also be cautioned to take note that high power radars are allocated as primary
users (meaning they have priority) of 5250-5350 MHz and 5650-5850 MHz and these radars
could cause interference and/or damage to LE-LAN devices.
This equipment complies with IC RSS-102 radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with minimum
distance 20cm between the radiator & your body.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils
radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1)
l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout
brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le
fonctionnement.
RCM
The product meets the requirements of the AS/NZS 2064 standard (Class A).
Approvals for Argentina
Devices of the SCALANCE W760/W720 series are approved in Argentina under the
following certification number:
Certification ID
Certification number
ELN-W1-RJ-E1
CNC: C-13172
Devices of the SCALANCE W770/W730 series are approved in Argentina under the
following certification numbers:
Certification ID
Certification number
MSN-W1-RJ-E2
CNC: C-13164
MSN-W1-M12-E2
CNC: C-13163
Approval for Brazil
Devices of the SCALANCE W760/W720 series are approved in Brazil under the following
certification numbers:
Este equipamento opera em caráter secundário, isto, ist é, não tem direito à proteção contra
interferência prejudicial, mesmo de estações do mesmo tipo e não pode causar interferência
a sistemas operando em caráter primário.
Approvals SCALANCE W700 802.11n
112
Reference Manual, 01/2017, C79000-G8976-C392-05
Approvals for SCALANCE W760/W720 802.11n
4.2 General approvals
Devices of the SCALANCE W770/W730 series are approved in Brazil under the following
certification numbers:
Este equipamento opera em caráter secundário, isto, ist é, não tem direito à proteção contra
interferência prejudicial, mesmo de estações do mesmo tipo e não pode causar interferência
a sistemas operando em caráter primário.
KCC Statement (Republic of Korea)
사용자안내문(제5조제1항제1호관련)
기종별
A 급 기기급 기기
(업무용 방송통신기기)
사용자안내문
이 기기는 업무용(A 급)으로 전자파적합등록을 한(A 급)으로
전자파적합등록을 한
기기이오니 판매자 또는 사용자는 이 점을
주의하시기 바라며, 가정외의 지역에서 사용하는
것을 목적으로 합니다.
"당해 무선설비는 전파혼신 가능성이 있으므로 인명안전과 관련된 서비스는 할 수 없음"
Marking for the customs union
EAC (Eurasian Conformity)
Customs union of Russia, Belarus and Kazakhstan
Declaration of the conformity according to the technical regulations of the customs union
(TR CU)
Railway approval for the SCALANCE W774-1 M12 EEC
The SCALANCE W774-1 M12 EEC device meets the requirements of the railway standard
EN 50155:2007 "Railway Applications - Electronic equipment used on rolling stock".
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
113
Approvals for SCALANCE W760/W720 802.11n
4.3 National approvals
4.3
National approvals
The following table lists the countries in which the SCALANCE W700 product is approved.
The diamond symbol (♦) identifies all countries for which there was no approval at the time
these operating instructions were written.
The current status of the approvals can be found on the Internet at the following address:
http://www.siemens.com/funkzulassungen
Column
Meaning
Country
Country
Mode
IEEE 802.11 standard and the TPC and / or DFS functionality, where required
CH
Channel
MHz
Frequency
PWR (EIRP)
Maximum permitted effective isotropic radiated power
Use
Permitted use indoors and / or outdoors
Approvals SCALANCE W700 802.11n
114
Reference Manual, 01/2017, C79000-G8976-C392-05
Approvals for SCALANCE W760/W720 802.11n
4.3 National approvals
Country
Mode
Andorra
Belgium
Bosnia and Herzegovina
Bulgaria
Denmark
Germany
Estonia
Finland
France
Greece
Great Britain
Ireland
Iceland
Italy
Croatia
Latvia
Liechtenstein
Lithuania
Luxembourg
Malta
Macedonia
Monaco
Montenegro
Netherlands
Norway
Austria
Poland
Portugal
Romania
San Marino
Sweden
Switzerland
Serbia
Slovakia
Slovenia
Spain
Czech Republic
Turkey
Hungary
Vatican
Cyprus
11g 11n
CH
MHz
PWR
(EIRP)
Use
13
2412
2472
100 mW Indoor + outdoor
36
48
5180
5240
200 mW Indoor only
TPC
52
64
5260
5320
200 mW Indoor only
DFS + TPC
100
116
5500
5580
1000 mW Indoor + outdoor
132
140
5660
5700
1000 mW Indoor + outdoor
11a 11n
11a 11n
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
115
Approvals for SCALANCE W760/W720 802.11n
4.3 National approvals
Country
Mode
Egypt
11g 11n
CH
11a 11n
TPC
Angola
11g 11n
11a 11n
TPC
11a 11n
DFS + TPC
MHz
2412
13
2472
36
5180
5320
2412
13
2472
36
5180
5240
52
5260
200 mW Indoor only
100 mW Indoor + outdoor
200 mW Indoor only
200 mW Indoor only
64
5320
100
5500
1000 mW Indoor + outdoor
116
5580
132
5660
100 mW Indoor + outdoor
48
Use
64
Argentina
PWR
(EIRP)
1000 mW Indoor + outdoor
140
5700
11g 11n
13
2412
2472
1000 mW Indoor + outdoor
11a 11n
36
48
5180
5240
50 mW Indoor + outdoor
11a 11n
52
64
5260
5320
250 mW Indoor + outdoor
100
120
5500
5600
250 mW Indoor + outdoor
132
140
5660
5700
250 mW Indoor + outdoor
149
165
5745
5825
1000 mW Indoor + outdoor
TPC
11a 11n
Approvals SCALANCE W700 802.11n
116
Reference Manual, 01/2017, C79000-G8976-C392-05
Approvals for SCALANCE W760/W720 802.11n
4.3 National approvals
Country
Mode
CH
Australia
11g 11n
13
2412
2472
100 mW Indoor + outdoor
11a 11n
36
48
5180
5240
200 mW Indoor only
11a 11n
52
64
5260
5320
200 mW Indoor only
11a 11n
149
165
5745
5825
400 mW Indoor + outdoor
11g 11n
13
2412
2472
100 mW Indoor + outdoor
11a 11n
36
48
5180
5240
200 mW Indoor only
11a 11n
52
64
5260
5320
200 mW Indoor only
11a 11n
149
165
5745
5825
2000 mW Indoor + outdoor
11g 11n
2412
100 mW Indoor + outdoor
New Zealand
DFS + TPC
Bahrain
DFS + TPC
Belarus
11a 11n
TCP
11a 11n
TCP + DFS
MHz
13
2472
36
5180
5240
52
5260
Use
100 mW Indoor + outdoor
48
100 mW Indoor + outdoor
64
5320
132
5660
Brazil
PWR
(EIRP)
100 mW Indoor + outdoor
140
5700
11g 11n
13
2412
2472
11a 11n
36
48
5180
5240
200 mW Indoor only
11a 11n
52
64
5260
5320
200 mW Indoor only
TPC
4000 mW Indoor + outdoor
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
117
Approvals for SCALANCE W760/W720 802.11n
4.3 National approvals
Country
Chile
Mode
CH
PWR
(EIRP)
Use
100
140
5500
5700
1000 mW Indoor + outdoor
11a 11n
149
165
5745
5825
4000 mW Indoor + outdoor
11g 11n
13
2412
2472
100 mW Indoor only
11a 11n
36
5180
100 mW Indoor only
TPC
11a 11n
DFS+TPC
11a 11n
DFS
China
MHz
11g 11n
11a 11n
TPC
11a 11n
DFS+TPC
11a 11n
48
5240
52
5260
100 mW Indoor only
64
5320
149
165
5745
5825
100 mW Indoor only
13
2412
100 mW Indoor + outdoor
2472
36
5180
48
5240
52
5260
200 mW Indoor only
200 mW Indoor only
64
5320
149
165
5745
5825
2000 mW Indoor + outdoor
Approvals SCALANCE W700 802.11n
118
Reference Manual, 01/2017, C79000-G8976-C392-05
Approvals for SCALANCE W760/W720 802.11n
4.3 National approvals
Country
Mode
Ivory Coast
11g 11n
CH
11a 11n
TPC
11a 11n
DFS + TPC
MHz
2412
13
2472
36
5180
5240
52
5260
100 mW Indoor + outdoor
200 mW Indoor only
200 mW Indoor only
64
5320
100
5500
1000 mW Indoor + outdoor
116
5580
132
5660
Use
48
Guatemala
PWR
(EIRP)
1000 mW Indoor + outdoor
140
5700
11g 11n
11
2412
2462
100 mW Indoor + outdoor
11a 11n
36
5180
200 mW Indoor only
11a 11n
DFS + TPC
48
5240
52
5260
5320
100
5500
400 mW Indoor + outdoor
116
5580
132
5660
400 mW Indoor + outdoor
64
11a 11n
400 mW Indoor + outdoor
140
5700
149
165
5745
5825
400 mW Indoor + outdoor
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
119
Approvals for SCALANCE W760/W720 802.11n
4.3 National approvals
Country
Mode
Hong Kong
11g 11n
CH
11a 11n
TPC
11a 11n
DFS + TPC
MHz
2412
13
2472
36
5180
5240
52
5260
11g 11n
11a 11n
TPC
5320
100
5500
11a 11n
DFS + TPC
5580
132
5660
11a 11n
5700
2412
13
2472
36
5180
Indonesia ♦
Israel
1000 mW Indoor + outdoor
1000 mW Indoor + outdoor
100 mW Indoor + outdoor
200 mW Indoor only
48
5240
52
5260
200 mW Indoor only
64
5320
149
5745
200 mW Indoor only
140
200 mW Indoor only
116
100 mW Indoor + outdoor
64
Use
48
India
PWR
(EIRP)
200 mW Indoor + outdoor
165
5825
11g 11n
13
2412
2472
100 mW Indoor + outdoor
11a 11n
149
161
5745
5805
400 mW Indoor + outdoor
11g 11n
13
2412
2472
100 mW Indoor + outdoor
36
5180
200 mW Indoor only
11a 11n
TPC
11a 11n
DFS + TPC
48
5240
52
64
5260
5320
200 mW Indoor only
Approvals SCALANCE W700 802.11n
120
Reference Manual, 01/2017, C79000-G8976-C392-05
Approvals for SCALANCE W760/W720 802.11n
4.3 National approvals
Country
Mode
CH
Japan
11g 11n
13
2412
2472
100 mW Indoor + outdoor
11a
16
5040
5080
200 mW Indoor + outdoor
11a 11n
36
48
5180
5240
200 mW Indoor only
11a 11n
52
64
5260
5320
200 mW Indoor only
100
140
5500
5700
200 mW Indoor + outdoor
184
196
4920
4980
200 mW Indoor + outdoor
2412
100 mW Indoor + outdoor
DFS + TPC
11a
Kazakhstan
11g 11n
MHz
11a 11n
TPC
11a 11n
DFS + TPC
2472
36
5180
Korea
11g 11n
100 mW Indoor + outdoor
48
5240
52
5260
Use
13
100 mW Indoor + outdoor
64
5320
132
5660
Qatar
PWR
(EIRP)
100 mW Indoor + outdoor
140
5700
2412
100 mW Indoor only
13
2472
11a 11n
149
165
5745
5825
100 mW Indoor only
11g 11n
13
2412
2472
400 mW Indoor + outdoor
149
161
5745
5805
400 mW Indoor + outdoor
11a 11n
TPC
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
121
Approvals for SCALANCE W760/W720 802.11n
4.3 National approvals
Country
Mode
Kuwait
11g 11n
CH
100 mW Indoor + outdoor
36
48
5180
5240
100 mW Indoor + outdoor
TPC
52
64
5260
5320
100 mW Indoor + outdoor
DFS + TPC
11g 11n
13
2412
2472
100 mW Indoor + outdoor
11a 11n
149
161
5745
5805
100 mW Indoor + outdoor
11g 11n
13
2412
2472
100 mW Indoor + outdoor
11a 11n
5180
5240
200 mW Indoor only
TPC
36
48
52
64
5260
5320
200 mW Indoor only
DFS + TPC
100
5500
11a 11n
11a 11n
5580
132
5660
11g 11n
5700
149
5745
11a 11n
DFS
5825
2412
11a 11n
2472
56
5280
5320
149
5745
165
200 mW Indoor only
64
200 mW Indoor + outdoor
13
400 mW Indoor + outdoor
165
1000 mW Indoor + outdoor
140
1000 mW Indoor + outdoor
116
Malaysia
Use
2412
2472
11a 11n
Madagascar
PWR
(EIRP)
13
11a 11n
Macau
MHz
1000 mW Indoor + outdoor
5825
Approvals SCALANCE W700 802.11n
122
Reference Manual, 01/2017, C79000-G8976-C392-05
Approvals for SCALANCE W760/W720 802.11n
4.3 National approvals
Country
Mode
Mexico
11g 11n
11
2412
2462
11a 11n
36
64
5180
5320
1000 mW Indoor only
149
165
5745
5825
1000 mW Indoor + outdoor
2412
100 mW Indoor + outdoor
Pakistan
CH
11g 11n
11a 11n
MHz
13
2472
149
5745
Russia
Use
100 mW Indoor + outdoor
100 mW Indoor + outdoor
165
5825
11g 11n
13
2412
2472
100 mW Indoor + outdoor
11a 11n
5180
5240
100 mW Indoor + outdoor
TPC
36
48
5260
5320
100 mW Indoor + outdoor
DFS + TPC
52
64
132
140
5660
5700
100 mW Indoor + outdoor
13
2412
2472
100 mW Indoor + outdoor
36
48
5180
5240
200 mW Indoor only
TPC
52
64
5260
5320
200 mW Indoor only
DFS + TPC
100
112
5500
5560
200 mW Indoor + outdoor
116
140
5580
5700
200 mW Indoor + outdoor
11a 11n
Saudi Arabia
PWR
(EIRP)
11g 11n
11a 11n
11a 11n
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
123
Approvals for SCALANCE W760/W720 802.11n
4.3 National approvals
Country
Mode
CH
Singapore
11b 11g 11n
Philippines
11a 11n
TPC
11a 11n
DFS + TPC
11a 11n
MHz
2412
13
2472
36
5180
5240
52
5260
Use
100 mW Indoor + outdoor
200 mW Indoor + outdoor
48
200 mW Indoor + outdoor
64
5320
100
116
5500
5580
1000 mW Indoor + outdoor
132
140
5660
5700
1000 mW Indoor + outdoor
149
5745
1000 mW Indoor + outdoor
South Africa
PWR
(EIRP)
165
5825
13
2412
2472
100 mW Indoor + outdoor
36
48
5180
5240
200 mW Indoor only
TPC
52
64
5260
5320
200 mW Indoor only
DFS+TPC
100
116
5500
5580
1000 mW Indoor + outdoor
132
140
5660
5700
1000 mW Indoor + outdoor
11g 11n
11a 11n
11a 11n
Approvals SCALANCE W700 802.11n
124
Reference Manual, 01/2017, C79000-G8976-C392-05
Approvals for SCALANCE W760/W720 802.11n
4.3 National approvals
Country
Mode
Taiwan ♦
11g 11n
CH
2412
100 mW Indoor + outdoor
200 mW Indoor + outdoor
10
2417
2457
11
2462
100 mW Indoor + outdoor
52
64
5260
5320
400 mW Indoor only
100
116
5500
5580
400 mW Indoor + outdoor
132
140
5660
5700
400 mW Indoor + outdoor
11a 11n
149
165
5745
5825
400 mW Indoor + outdoor
11g 11n
13
2412
2472
1000 mW Indoor + outdoor
11a 11n
36
48
5180
5240
200 mW Indoor only
52
64
5260
5320
1000 mW Indoor only
11a 11n
149
165
5745
5825
4000 mW Indoor + outdoor
11g 11n
13
2412
2472
100 mW Indoor + outdoor
36
48
5180
5240
200 mW Indoor only
TPC
52
64
5260
5320
200 mW Indoor only
DFS+TPC
100
116
5500
5580
1000 mW Indoor only
132
140
5660
5700
1000 mW Indoor only
11
2412
2462
11a 11n
DFS
11a 11n
11a 11n
Bahamas
Use
DFS+TPC
United Arab Emirates
PWR
(EIRP)
11a 11n
Venezuela
MHz
11g 11n
Canada
100 mW Indoor + outdoor
Approvals SCALANCE W700 802.11n
Reference Manual, 01/2017, C79000-G8976-C392-05
125
Approvals for SCALANCE W760/W720 802.11n
4.3 National approvals
Country
Mode
Colombia
11a 11n
CH
36
Peru
Puerto Rico
Thailand
USA
MHz
11a 11n
DFS + TPC
Uruguay
11a 11n
5180
48
5240
5260
Use
200 mW Indoor only
52
400 mW Indoor + outdoor
64
5320
100
116
5500
5580
400 mW Indoor + outdoor
132
140
5660
5700
400 mW Indoor + outdoor
149
5745
400 mW Indoor + outdoor
Vietnam
PWR
(EIRP)
165
5825
13
2412
2472
100 mW Indoor + outdoor
36
48
5180
5240
200 mW Indoor only
TPC
52
64
5260
5320
200 mW Indoor only
DFS+TPC
100
116
5500
5580
1000 mW Indoor + outdoor
132
140
5660
5700
1000 mW Indoor + outdoor
149
165
5745
5825
400 mW Indoor + outdoor
11g 11n
11a 11n
11a 11n
11a 11n
Approvals SCALANCE W700 802.11n
126
Reference Manual, 01/2017, C79000-G8976-C392-05

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Create Date                     : 2017:09:06 16:36:00+02:00
Page Count                      : 126
XMP Toolkit                     : XMP Core 4.1.1
Part                            : 1
Conformance                     : B
Producer                        : PDF-XChange Printer 2012 (5.5 build 315) [Windows 7 Enterprise x64 (Build 7601: Service Pack 1)]
Modify Date                     : 2017:09:06 16:36+02:00
Format                          : application/pdf
EXIF Metadata provided by EXIF.tools
FCC ID Filing: LYHMSN65V1

Navigation menu