Siemens MSN65V1 Industrial Wireless LAN access point User Manual
Siemens AG Industrial Wireless LAN access point Users Manual
Siemens >
Contents
- 1. User Manual
- 2. Users Manual
Users Manual
W780 / W740 802.11n W788C / W786C 802.11n SIMATIC NET W770/W730 802.11n Industrial Wireless LAN Approvals SCALANCE W700 802.11n W760/W720 802.11n Reference Manual 01/2017 C79000-G8976-C392-05 Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. indicates that minor personal injury can result if proper precautions are not taken. NOTICE indicates that property damage can result if proper precautions are not taken. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: Trademarks WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Division Process Industries and Drives Postfach 48 48 90026 NÜRNBERG GERMANY C79000-G8976-C392-05 Ⓟ 01/2017 Subject to change Copyright © Siemens AG 2014 - 2017. All rights reserved Table of contents Approvals for SCALANCE W780 / W740 802.11n ................................................................................. 5 1.1 1.1.1 1.1.2 1.1.3 1.1.3.1 1.1.3.2 1.1.3.3 1.1.4 EC declaration of conformity ................................................................................................ 7 ATEX .................................................................................................................................. 8 RoHS .................................................................................................................................. 8 R&TTE / RED...................................................................................................................... 8 Protection of health and safety ............................................................................................ 8 EMC.................................................................................................................................... 9 Efficient use of the radio spectrum ....................................................................................... 9 Products............................................................................................................................ 10 1.2 General approvals ............................................................................................................. 12 1.3 National approvals............................................................................................................. 21 Approvals for SCALANCE W788C / W786C 802.11n ...........................................................................39 2.1 2.1.1 2.1.2 2.1.3 2.1.3.1 2.1.3.2 2.1.3.3 2.1.4 EC declaration of conformity .............................................................................................. 40 ATEX ................................................................................................................................ 41 RoHS ................................................................................................................................ 41 R&TTE / RED.................................................................................................................... 41 Protection of health and safety .......................................................................................... 41 Efficient use of the radio spectrum ..................................................................................... 42 EMC.................................................................................................................................. 42 Products............................................................................................................................ 43 2.2 General approvals ............................................................................................................. 44 2.3 National approvals............................................................................................................. 52 Approvals for SCALANCE W770/W730 802.11n..................................................................................69 3.1 3.1.1 3.1.2 3.1.3 3.1.3.1 3.1.3.2 3.1.3.3 3.1.4 EC declaration of conformity .............................................................................................. 70 ATEX ................................................................................................................................ 71 RoHS ................................................................................................................................ 71 R&TTE / RED.................................................................................................................... 71 Protection of health and safety .......................................................................................... 71 EMC.................................................................................................................................. 72 Efficient use of the radio spectrum ..................................................................................... 72 Products W770/W730 ....................................................................................................... 73 3.2 General approvals ............................................................................................................. 74 3.3 SCALANCE W774/734 national approvals......................................................................... 80 3.4 SCALANCE W778/738 national approvals......................................................................... 95 Approvals for SCALANCE W760/W720 802.11n............................................................................... 103 4.1 4.1.1 4.1.2 4.1.3 EC declaration of conformity ............................................................................................ 104 ATEX .............................................................................................................................. 105 RoHS .............................................................................................................................. 105 R&TTE / RED.................................................................................................................. 105 Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 Table of contents 4.1.3.1 4.1.3.2 4.1.3.3 4.1.4 Protection of health and safety ........................................................................................ 105 EMC ............................................................................................................................... 106 Efficient use of the radio spectrum ................................................................................... 106 Products...........................................................................................................................107 4.2 General approvals ............................................................................................................108 4.3 National approvals............................................................................................................114 Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 Approvals for SCALANCE W780 / W740 802.11n Note Issued approvals on the type plate of the device The specified approvals apply only when the corresponding mark is printed on the product. You can check which of the following approvals have been granted for your product by the markings on the type plate. Range of validity The approvals listed in this section apply to the following products: Article number of the RoW version: Article number of the US version: Article number of the Israel version: 6GK5 786-1FC00-0AA0 6GK5 786-1FC00-0AB0 SCALANCE W786-2 RJ-45 6GK5 786-2FC00-0AA0 6GK5 786-2FC00-0AB0 6GK5786-2FC00-0AC0 SCALANCE W786-2IA RJ-45 6GK5 786-2HC00-0AA0 6GK5 786-2HC00-0AB0 SCALANCE W786-2 SFP 6GK5 786-2FE00-0AA0 6GK5 786-2FE00-0AB0 Article number of the RoW version: Article number of the US version: Article number of the Israel version: SCALANCE W788-1 RJ-45 6GK5788-1FC00-0AA0 6GK5788-1FC00-0AB0 SCALANCE W788-1 M12 6GK5788-1GD00-0AA0 6GK5788-1GD00-0AB0 6GK5788-2FC00-0AA0 6GK5788-2FC00-0AB0 6GK5788-2FC00-0AC0 SCALANCE W788-2 M12 6GK5788-2GD00-0AA0 6GK5788-2GD00-0AB0 SCALANCE W788-2 M12 EEC 6GK5788-2GD00-0TA0 6GK5788-2GD00-0TB0 SCALANCE W748-1 RJ-45 6GK5748-1FC00-0AA0 6GK5748-1FC00-0AB0 SCALANCE W748-1 M12 6GK5748-1GD00-0AA0 6GK5748-1GD00-0AB0 Access point SCALANCE W786-1 RJ-45 Dual access points Access points Dual access points SCALANCE W788-2 RJ-45 Ethernet client modules Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 ApprovalsforSCALANCEW780/W740802.11n 1.1 EC declaration of conformity Abbreviations used Some approvals apply only to certain devices or series. In such situations, the designations of the products are shortened to avoid having to list all the type designations. The following table shows how the abbreviations relate to the product variants. Product group The designation . . . stands for . . . Product name Access points (IP30 and IP65) W788-x SCALANCE W788-1 M12 SCALANCE W788-2 M12 SCALANCE W788-2 M12 EEC SCALANCE W788-1 RJ-45 SCALANCE W788-2 RJ-45 Access points (IP65) W786-x SCALANCE W786-1 RJ-45 SCALANCE W786-2 RJ-45 SCALANCE W786-2IA RJ-45 SCALANCE W786-2 SFP SCALANCE W without W786-x W7x8 SCALANCE W788-1 RJ-45 SCALANCE W788-1 M12 SCALANCE W788-2 RJ-45 SCALANCE W788-2 M12 SCALANCE W788-2 M12 EEC SCALANCE W748-1 RJ-45 SCALANCE W748-1 M12 Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 ApprovalsforSCALANCEW780/W740802.11n 1.1 EC declaration of conformity 1.1 EC declaration of conformity The EC Declaration of Conformity is available for all responsible authorities at: Siemens Aktiengesellschaft Process Industries and Drives Division, Process Automation DE-76181 Karlsruhe Germany You will find the current EC declaration of conformity for these products on the Internet pages of Siemens Industry Online Support (hhttps://support.industry.siemens.com/cs/ww/en/ps/15853/cert). The SIMATIC NET products described in these Operating Instructions meet the requirements of the following EC directives: ● 94/9/EC Directive of the European Parliament and the Council of 23 March 1994 on the approximation of the laws of the Member States concerning equipment and protective systems intended for use in potentially explosive atmospheres (until 19.04.2016). ● 2014/34/EU Directive 2014/34/EU of the European Parliament and of the Council of 26 February 2014 on the harmonization of the laws of the Member States relating to equipment and protective systems intended for use in potentially explosive atmospheres official journal of the EU L96, 29/03/2014, pages. 309–356 (as of 20.04.2016) ● 1999/5/EC Directive of the European Parliament and of the Council of 1999 March 1999 on Radio Equipment and Telecommunications Terminal Equipment and the mutual recognition of their conformity (until 12.06.2016). ● 2014/53/EU Directive of the European Parliament and of the Council of April 16, 2014 on the harmonization of the laws of the member states relating to placing radio equipment on the market.; official journal of the EU L153, 22/05/2014, pages. 62–106 (as of 13.06.2016) ● 2011/65/EU (RoHS) RoHS directive of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment. ● 1999/519/EC Council recommendation on the limitation of exposure of the general public to electromagnetic fields (0 Hz to 300 GHz) Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 ApprovalsforSCALANCEW780/W740802.11n 1.1 EC declaration of conformity 1.1.1 ATEX ATEX directive (correct usage in potentially explosive atmospheres) The SIMATIC NET product meets the requirements of the EC directive:94/9/EC (until 19.04.2016) and 2014/34/EU (as of 20.04.2016) "Equipment and Protective Devices for Use in Potentially Explosive Atmospheres" according to the standards listed in the section Products (Page 10): Applied standard: EN 60079-0 + A11 Hazardous areas - Part 0: Equipment - General requirements EN 60079-15 Explosive atmospheres - Part 15: Equipment protection by type of protection "n" 1.1.2 RoHS RoHS directive (restriction of the use of certain hazardous substances) The SIMATIC NET products described in these operating instructions meet the requirements of the EC directive 2011/65/EC for the restriction of the use of certain hazardous substances in electrical and electronic equipment: Applied standard: EN 50581 Technical documentation for the assessment electrical and electronic products with respect to restriction of hazardous substances 1.1.3 R&TTE / RED 1.1.3.1 Protection of health and safety Article 3 (1) a) protection of health and safety EN 60950-1+A1+A2+A11+A12 Information technology equipment - Safety - Part 1: General requirements EN 62311 Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz – 300 GHz) Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 ApprovalsforSCALANCEW780/W740802.11n 1.1 EC declaration of conformity 1.1.3.2 EMC Art. 3 (1) b - EMC EN 50121-3-2+AC Railway applications - Electromagnetic compatibility - part 3-2: Railway Vehicles Devices EN 50121-4+AC Railway applications - Electromagnetic compatibility - part 4: Interference emissions and immunity of signal telecommunications equipment ETSI EN 301 489-1 Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic compatibility for radio equipment and services - Part 1 : Common technical requirements ETSI EN 301 489-17 10 11 12 13 1.1.3.3 Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic compatibility for radio equipment and services - Part 17 : EN 61000-6-1 Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments EN 61000-6-2+AC Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments EN 61000-6-3+A1+AC Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments EN 61000-6-4+A1 Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments Efficient use of the radio spectrum Art. 3 (2) Efficient use of the radio spectrum 14 ETSI EN 301 328 Electromagnetic compatibility and radio spectrum matters (ERM) - wideband transmission systems - data transmission equipment operating in the 2.4 GHz ISM band and using wideband modulation techniques. Harmonized EN containing the essential requirements according to Article 3.2 of the R&TTE directive. 15 ETSI EN 301 893 Broadband Radio Access Networks (BRAN) - 5 GHz high performance RLAN Harmonized EN covering essential requirements of article 3.2 of the R&TTE Directive Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 ApprovalsforSCALANCEW780/W740802.11n 1.1 EC declaration of conformity 1.1.4 Products Product designation and standards The standards that apply to the product are described in RoHS (Page 8), ATEX (Page 8) and R&TTE / RED (Page 8). Product name Standards W786-1 RJ45 1, 2 3, 4, 5, 8, 9, 10, 11, 12, 13, 14, 15, W786-2 RJ45 W786-2IA RJ45 W786-2 SFP W788-1 RJ45 W788-2 RJ45 W788-1 M12 W788-2 M12 W748-1 RJ45 W748-1 M12 W788-2 M12 EEC 1, 2 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15 Approvals SCALANCE W700 802.11n 10 Reference Manual, 01/2017, C79000-G8976-C392-05 ApprovalsforSCALANCEW780/W740802.11n 1.1 EC declaration of conformity Certification ID The following tables show the product names and the corresponding certification ID: Type Number and type of Number of interthe Ethernet interfaces nal antennas Number of R-SMA sockets for external antennas W786-1 RJ-45 1 x RJ-45 EAPN-W1-RJ-E3 6GK5 786-1FC00-0AA0 6GK5 786-1FC00-0AB0 W786-2 RJ-45 1 x RJ-45 EAPN-W2-RJ-E3 6GK5 786-2FC00-0AA0 6GK5 786-2FC00-0AB0 W786-2IA RJ-45 1 x RJ-45 EAPN-W2-RJ-I3 6GK5 786-2HC00-0AA0 6GK5 786-2HC00-0AB0 W786-2 SFP 2 x SFP EAPN-W2-SFP-E3 6GK5 786-2FE00-0AA0 Certification ID Article number Article number US variant 6GK5 786-2FE00-0AB0 Type Certification ID Article number: Article number US variant W788-1 RJ-45 RAPN-W1-RJ-E3 6GK 5788-1FC00-0AA0 6GK 5788-1FC00-0AB0 W788-2 RJ-45 RAPN-W2-RJ-E3 6GK5 788-2FC00-0AA0 6GK5 788-2FC00-0AB0 W788-1 M12 RAPN-W1-M12-E3 6GK5 788-1GD00-0AA0 6GK5 788-1GD00-0AB0 W788-2 M12 RAPN-W2-M12-E3 6GK5 788-2GD00-0AA0 6GK5 788-2GD00-0AB0 W788-2 M12 EEC RAPN-W2-M12-E3 6GK5 788-2GD00-0TA0 6GK5 788-2GD00-0TB0 W748-1 RJ-45 RAPN-W1-RJ-E3 6GK5 748-1FC00-0AA0 6GK5 748-1FC00-0AB0 W748-1 M12 RAPN-W1-M12-E3 6GK5 748-1GD00-0AA0 6GK5 748-1GD00-0AB0 Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 11 ApprovalsforSCALANCEW780/W740802.11n 1.2 General approvals 1.2 General approvals ATEX (explosion protection directive) WARNING When using SIMATIC NET products in hazardous area zone 2, make absolutely sure that the associated conditions in the following document are adhered to: "SIMATIC NET Product Information Use of subasseblies/modules in a Zone 2 Hazardous Area". You will find this document on the data medium that ships with some devices. on the Internet pages of Siemens Industry Online Support (http://support.automation.siemens.com/ww). Enter the document identification number C234 as the search term. The SIMATIC NET products meet the requirements of the EC directive 94/9/EC "Equipment and Protective Devices for Use in Potentially Explosive Atmospheres”. and as of 20.04.2016 the EC directive 2014/34/EU. ATEX classification: II 3 G Ex nA IIC T4 Gc KEMA 07ATEX0145 X The products meet the requirements of the following standards: ● EN 60079-15 (electrical apparatus for potentially explosive atmospheres; Type of protection "n") ● EN 60079-0 (Explosive atmospheres - Part 0: Equipment - General requirements) You will find the current versions of the standards in the currently valid ATEX certificates. IECEx The SIMATIC NET products meet the requirements of explosion protection according to IECEx. IECEx classification: Ex nA IIC T4 Gc DEK 14.0025X The products meet the requirements of the following standards: ● IEC 60079-15 (Explosive atmospheres - Part 15: Equipment protection by type of protection "n") ● IEC 60079-0 (Explosive atmospheres - Part 0: Equipment - General requirements) You will find the current versions of the standards in the currently valid IECEx certificates. Approvals SCALANCE W700 802.11n 12 Reference Manual, 01/2017, C79000-G8976-C392-05 ApprovalsforSCALANCEW780/W740802.11n 1.2 General approvals FM The product meets the requirements of the standards: ● Factory Mutual Approval Standard Class Number 3611 ● FM Hazardous (Classified) Location Electrical Equipment: Non Incendive / Class I / Division 2 / Groups A,B,C,D / T4 and Non Incendive / Class I / Zone 2 / Group IIC / T4 cULus Approval for Information Technology Equipment cULus Listed I. T. E. Underwriters Laboratories Inc. complying with ● UL 60950-1 (Information Technology Equipment) ● CSA C22.2 No. 60950-1-03 Report no. E115352 Note Only devices of the SCALANCE W786-x series have this approval. cULus Approval Hazardous Location cULus Listed I. T. E. FOR HAZ. LOC. Underwriters Laboratories Inc. complying with ● UL 60950-1 (Information Technology Equipment) ● ANSI/ISA 12.12.01-2007 ● CSA C22.2 No. 213-M1987 Approved for use in Cl. 1, Div. 2, GP A, B, C, D T4 Cl. 1, Zone 2, GP IIC T4 Report no. E240480 Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 13 ApprovalsforSCALANCEW780/W740802.11n 1.2 General approvals FCC approval This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Notice Changes or modifications made to this equipment not expressly approved by SIEMENS may void the FCC authorization to operate this equipment. IEEE 802.11b or g operation of this product in the USA is firmware-limited to channels 1 through 11. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ● Reorient or relocate the receiving antenna. ● Increase the separation between the equipment and receiver. ● Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ● Consult the dealer or an experienced radio/TV technician for help. Notice This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Professional Installation Notice: To comply with FCC part 15 rules in the United States, the system must be professionally installed to ensure compliance with the Part 15 certification. It is the responsibility of the operator and professional installer to ensure that only certified systems are deployed in the United States. The use of the system in any other combination (such as co-located antennas transmitting the same information) is expressly forbidden. Approvals SCALANCE W700 802.11n 14 Reference Manual, 01/2017, C79000-G8976-C392-05 ApprovalsforSCALANCEW780/W740802.11n 1.2 General approvals Notice For use of DFS channels ● Use of the RCoax Cable Antenna 6XV1875-2D is not permitted in channels which require dynamic frequency selection (DFS). ● Any installation of either a master or a client device within 35 km of a TDWR (Terminal Doppler Weather Radar) location shall be separated by at least 30 MHz (center-to-center) from the TDWR operating frequency. These devices shall be registered in the industry sponsored WISPA database, http://udia.spectrumbridge.com/udia/home.aspx (http://udia.spectrumbridge.com/udia/home.aspx) When you open this link, you get the following choices: – "Search" opens a window with TDWR locations and frequencies. – "User Signup" allows you to register as user of the database. – After registering you can Logon and register your WLAN location. Please fill in all required information. For more information with respect to WISPA database and TWDR locations please consult FCC publication KDB 443999 D01. NEMA TS2 The product meets the requirements of the standard NEMA TS2 (Traffic Controller Assemblies with NTCIP Requirements) SCALANCE W788-2 M12 EEC 6GK5788-2GD00-0TA0 6GK5788-2GD00-0TB0 RSS-247 of Industry Canada for SCALANCE W786-x This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. This radio transmitter (IC: 267AA-MPCIE1V1) has been approved by Industry Canada to operate with the antenna types listed in section 6.8 with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 15 ApprovalsforSCALANCEW780/W740802.11n 1.2 General approvals To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that permitted for successful communication. That the device for the band 5150-5250 MHz is only for indoor usage to reduce potential for harmful interference to co-channel mobile satellite systems. Users should also be cautioned to take note that high power radars are allocated as primary users (meaning they have priority) of 5250-5350 MHz and 5650-5850 MHz and these radars could cause interference and/or damage to LE-LAN devices. This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. RSS-247 of Industry Canada for SCALANCE W7x8 This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. This radio transmitter (IC: 267AA-MPCIE1V1) has been approved by Industry Canada to operate with the antenna types listed in section 5.4 with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that permitted for successful communication. That the device for the band 5150-5250 MHz is only for indoor usage to reduce potential for harmful interference to co-channel mobile satellite systems. Users should also be cautioned to take note that high power radars are allocated as primary users (meaning they have priority) of 5250-5350 MHz and 5650-5850 MHz and these radars could cause interference and/or damage to LE-LAN devices. This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. Approvals SCALANCE W700 802.11n 16 Reference Manual, 01/2017, C79000-G8976-C392-05 ApprovalsforSCALANCEW780/W740802.11n 1.2 General approvals Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Note for USA, Canada, Puerto Rico, Peru, Bahamas, Ecuador and Columbia When operating the SCALANCE W700 with DFS (Dynamic Frequence Selection), the IWLAN RCoax Cable 5 GHz (order number 6XV1875-2D) may not be used in the countries listed above. Approvals in Argentina Devices of the SCALANCE W786-x series are approved in Argentina under the following certification numbers: Certification ID Certification number EAPN-W1-RJ-E3 CNC: C-11549 EAPN-W2-RJ-E3 CNC: C-11536 EAPN-W2-RJ-I3 CNC: C-11564 EAPN-W2-SFP-E3 CNC: C-11547 Devices of the SCALANCE W788-x series are approved in Argentina under the following certification numbers: Certification ID Certification number RAPN-W1-RJ-E3 CNC: C-11541 RAPN-W2-RJ-E3 CNC: C-11502 RAPN-W1-M12-E3 CNC: C-11546 RAPN-W2-M12-E3 CNC: C-11548 Approval in Brazil From the SCALANCE W786-x series, the following devices are approved for Brazil: Type Order number EAPN number W786-1 RJ-45 6GK5 786-1FC00-0AA0 EAPN-W1-RJ-E3 W786-2 RJ-45 6GK5 786-2FC00-0AA0 EAPN-W2-RJ-E3 W786C-2 RJ-45 6GK5 786-2FC00-1AA0 EAPN-W2-RJ-E3 W786-2IA RJ-45 6GK5 786-2HC00-0AA0 EAPN-W2-RJ-I3 W786C-2IA RJ-45 6GK5 786-2HC00-1AA0 EAPN-W2-RJ-I3 W786-2 SFP 6GK5 786-2FE00-0AA0 EAPN-W2-SFP-E3 The listed devices are approved in Brazil under the following certification numbers: Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 17 ApprovalsforSCALANCEW780/W740802.11n 1.2 General approvals Este equipamento opera em caráter secundário, isto, ist é, não tem direito à proteção contra interferência prejudicial, mesmo de estações do mesmo tipo e não pode causar interferência a sistemas operando em caráter primário. From the SCALANCE W7x8 series, the following devices are approved for Brazil: Type Order number RAPN number W788-1 RJ-45 6GK 5788-1FC00-0AA0 RAPN-W1-RJ-E3 W788-2 RJ-45 6GK5 788-2FC00-0AA0 RAPN-W2-RJ-E3 W788-1 M12 6GK5 788-1GD00-0AA0 RAPN-W1-M12-E3 W788-2 M12 6GK5 788-2GD00-0AA0 RAPN-W2-M12-E3 W788-2 M12 EEC 6GK5 788-2GD00-0TA0 RAPN-W2-M12-E3 W748-1 RJ-45 6GK5 748-1FC00-0AA0 RAPN-W1-RJ-E3 W748-1 M12 6GK5 748-1GD00-0AA0 RAPN-W1-M12-E3 W788C-2 RJ-45 6GK 5788-2FC00-1AA0 RAPN-W2-RJ-E3 W788C-2 M12 6GK5 788-2GD00-1AA0 RAPN-W2-M12-E3 W788C-2 M12 EEC 6GK5788-2GD00-1TA0 RAPN-W2-M12-E3 The listed devices are approved in Brazil under the following certification numbers: Este equipamento opera em caráter secundário, isto, ist é, não tem direito à proteção contra interferência prejudicial, mesmo de estações do mesmo tipo e não pode causar interferência a sistemas operando em caráter primário. Approvals SCALANCE W700 802.11n 18 Reference Manual, 01/2017, C79000-G8976-C392-05 ApprovalsforSCALANCEW780/W740802.11n 1.2 General approvals KCC Statement (Republic of Korea) 사용자안내문(제5조제1항제1호관련) 기종별 A 급 기기급 기기 (업무용 방송통신기기) 사용자안내문 이 기기는 업무용(A 급)으로 전자파적합등록을 한(A 급)으로 전자파적합등록을 한 기기이오니 판매자 또는 사용자는 이 점을 주의하시기 바라며, 가정외의 지역에서 사용하는 것을 목적으로 합니다. "당해 무선설비는 전파혼신 가능성이 있으므로 인명안전과 관련된 서비스는 할 수 없음" Approval for Mexico The WLAN modules included in the devices have the following certification number: RCPSIMP12-0751 Approval for Oman Devices of the SCALANCE W786-x series are approved in Oman under the following certification numbers: OMAN-TRA R/1773/14 D090258 Devices of the SCALANCE W788-x series are approved in Oman under the following certification numbers: OMAN-TRA R/1772/14 D090258 NCC Warning Statement (Taiwan) Article 12 Without permission, any company, firm or user shall not alter the frequency, increase the power, or change the characteristics and functions of the original design of the certified lower power frequency electric machinery. Article 14 The application of low power frequency electric machineries shall not affect the navigation safety nor interfere a legal communication, if an interference is found, the service will be suspended until improvement is made and the interference no longer exists. Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 19 ApprovalsforSCALANCEW780/W740802.11n 1.2 General approvals Marking for the customs union EAC (Eurasian Conformity) Customs union of Russia, Belarus and Kazakhstan Declaration of the conformity according to the technical regulations of the customs union (TR CU) Approvals SCALANCE W700 802.11n 20 Reference Manual, 01/2017, C79000-G8976-C392-05 ApprovalsforSCALANCEW780/W740802.11n 1.3 National approvals 1.3 National approvals The following table lists the countries in which the SCALANCE W700 product is approved. The diamond symbol (♦) identifies all countries for which there was no approval at the time these operating instructions were written. The current status of the approvals can be found on the Internet at the following address: http://www.siemens.com/funkzulassungen Column Meaning Country Country Mode IEEE 802.11 standard and the TPC and / or DFS functionality, where required CH Channel MHz Frequency PWR (EIRP) Maximum permitted effective isotropic radiated power Use Permitted use indoors and / or outdoors Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 21 ApprovalsforSCALANCEW780/W740802.11n 1.3 National approvals Country Mode Andorra Belgium Bosnia and Herzegovina Bulgaria Denmark Germany Estonia Finland France Greece Great Britain Ireland Iceland Italy Croatia Latvia Liechtenstein Lithuania Luxembourg Malta Macedonia Monaco Montenegro Netherlands Norway Austria Poland Portugal Romania San Marino Sweden Switzerland Slovakia Slovenia Spain Czech Republic Turkey Hungary Vatican Cyprus 11g 11n CH MHz PWR (EIRP) Use 13 2412 2472 100 mW Indoor + outdoor 36 48 5180 5240 200 mW Indoor only TPC 52 64 5260 5320 200 mW Indoor only DFS + TPC 100 116 5500 5580 1000 mW Indoor + outdoor 132 140 5660 5700 1000 mW Indoor + outdoor 149 165 5745 5825 25 mW Indoor + outdoor 11a 11n 11a 11n 11a 11n Approvals SCALANCE W700 802.11n 22 Reference Manual, 01/2017, C79000-G8976-C392-05 ApprovalsforSCALANCEW780/W740802.11n 1.3 National approvals Country Mode Egypt 11g 11n CH 11a 11n TPC Angola 11g 11n 11a 11n TPC 11a 11n DFS + TPC MHz 2412 13 2472 36 5180 5320 2412 13 2472 36 5180 48 5240 5260 11g 11n 11a 11n 5320 100 5500 11a 11n TPC 5580 132 5660 5700 2412 13 2472 36 5180 48 5240 5260 11a 11n 5320 100 5500 5600 132 5660 1000 mW Indoor + outdoor 50 mW Indoor + outdoor 250 mW Indoor + outdoor 250 mW Indoor + outdoor 250 mW Indoor + outdoor 140 5700 149 5745 1000 mW Indoor + outdoor 120 165 1000 mW Indoor + outdoor 64 200 mW Indoor only 52 200 mW Indoor only 140 100 mW Indoor + outdoor 116 200 mW Indoor only 64 100 mW Indoor + outdoor 52 Use 64 Argentina PWR (EIRP) 1000 mW Indoor + outdoor 5825 Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 23 ApprovalsforSCALANCEW780/W740802.11n 1.3 National approvals Country Mode Australia 11g 11n CH New Zealand 11a 11n MHz 2412 13 2472 36 5180 11a 11n DFS + TPC 11a 11n 5240 52 5260 11g 11n 11a 11n 5320 149 5745 11a 11n DFS + TPC 5825 2412 11a 11n 2472 36 5180 Belarus 11g 11n 11a 11n TCP 5240 52 5260 11a 11n TCP + DFS 5320 149 5745 5825 2412 13 2472 36 5180 5240 52 5260 2000 mW Indoor + outdoor 100 mW Indoor + outdoor 100 mW Indoor + outdoor 100 mW Indoor + outdoor 64 5320 132 5660 140 200 mW Indoor only 48 200 mW Indoor only 165 100 mW Indoor + outdoor 64 400 mW Indoor + outdoor 48 200 mW Indoor only 13 200 mW Indoor only 165 100 mW Indoor + outdoor 64 Use 48 Bahrain PWR (EIRP) 100 mW Indoor + outdoor 5700 Approvals SCALANCE W700 802.11n 24 Reference Manual, 01/2017, C79000-G8976-C392-05 ApprovalsforSCALANCEW780/W740802.11n 1.3 National approvals Country Mode Brazil 11g 11n CH 11a 11n MHz 2412 13 2472 36 5180 11a 11n TPC 5240 52 5260 Chile 11g 11n 11a 11n TPC 5320 100 5500 11a 11n DFS + TPC 5700 149 5745 11a 11n DFS China 11g 11n 5825 2412 13 2472 36 5180 5240 52 5260 11a 11n TPC 5320 149 5745 11a 11n DFS + TPC 5825 2412 11a 11n 2472 36 5180 Ivory Coast 11g 11n 5240 52 5260 100 mW Indoor only 100 mW Indoor + outdoor 200 mW Indoor only 200 mW Indoor only 64 5320 149 5745 2000 mW Indoor + outdoor 165 5825 2412 13 100 mW Indoor only 48 100 mW Indoor only 13 100 mW Indoor only 165 4000 mW Indoor + outdoor 64 1000 mW Indoor + outdoor 48 200 mW Indoor only 165 200 mW Indoor only 140 4000 mW Indoor + outdoor 64 Use 48 11a 11n PWR (EIRP) 100 mW Indoor + outdoor 2472 Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 25 ApprovalsforSCALANCEW780/W740802.11n 1.3 National approvals Country Mode CH 11a 11n MHz 36 TPC 11a 11n DFS + TPC 5240 5260 11a 11n DFS + TPC 5320 100 5500 200 mW Indoor only 1000 mW Indoor + outdoor 116 5580 132 5660 1000 mW Indoor + outdoor 140 5700 2412 100 mW Indoor + outdoor 2417 200 mW Indoor + outdoor 10 2457 11 2462 100 mW Indoor + outdoor 36 5180 200 mW Indoor only 48 5240 52 5260 64 5320 5500 400 mW Indoor + outdoor 116 5580 132 5660 400 mW Indoor + outdoor 100 Hong Kong 200 mW Indoor only 64 11a 11n Use 52 11g 11n 5180 48 Guatemala PWR (EIRP) 400 mW Indoor + outdoor 140 5700 11a 11n 149 165 5745 5825 400 mW Indoor + outdoor 11g 11n 2412 100 mW Indoor + outdoor 11a 11n TPC 11a 11n DFS + TPC 13 2472 36 5180 48 5240 52 5260 64 200 mW Indoor only 200 mW Indoor only 5320 Approvals SCALANCE W700 802.11n 26 Reference Manual, 01/2017, C79000-G8976-C392-05 ApprovalsforSCALANCEW780/W740802.11n 1.3 National approvals Country Mode CH MHz 100 11g 11n 11a 11n TPC 11a 11n DFS + TPC 11a 11n 5580 5660 5700 2412 13 2472 36 5180 11g 11n 48 5240 5260 11a 11n TPC 5320 149 5745 11a 11n DFS + TPC 5825 2412 Indonesia ♦ 11g 11n 2472 36 5180 200 mW Indoor + outdoor 100 mW Indoor + outdoor 200 mW Indoor only 48 5240 52 5260 200 mW Indoor only 64 5320 2412 100 mW Indoor + outdoor 2417 200 mW Indoor + outdoor 10 2457 11 2462 11a 11n 200 mW Indoor only 13 200 mW Indoor only 165 100 mW Indoor + outdoor 64 1000 mW Indoor + outdoor 52 1000 mW Indoor + outdoor 140 Use 132 Israel 5500 116 India PWR (EIRP) 13 2472 149 5745 161 100 mW Indoor + outdoor 400 mW Indoor + outdoor 5805 Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 27 ApprovalsforSCALANCEW780/W740802.11n 1.3 National approvals Country Mode Japan 11g 11n CH MHz 2412 200 mW Indoor + outdoor 13 2472 16 5040 5080 200 mW Indoor + outdoor 11a 11n 36 5180 200 mW Indoor only 11a 11n DFS + TPC 11a 11g 11n 5240 52 5260 TPC 11a 11n DFS + TPC 5320 100 5500 11a 11n 200 mW Indoor + outdoor 140 5700 184 196 4920 4980 200 mW Indoor + outdoor 2412 100 mW Indoor + outdoor 13 2472 36 5180 5240 52 5260 100 mW Indoor only 48 100 mW Indoor only 64 5320 132 5660 11g 11n 200 mW Indoor only 64 11a 11n 48 Qatar Use 11a Kazakhstan PWR (EIRP) 100 mW Indoor + outdoor 140 5700 2412 13 2472 149 165 5745 5825 100 mW Indoor only 100 mW Indoor only Approvals SCALANCE W700 802.11n 28 Reference Manual, 01/2017, C79000-G8976-C392-05 ApprovalsforSCALANCEW780/W740802.11n 1.3 National approvals Country Mode Colombia 11g 11n CH MHz 2412 100 mW Indoor + outdoor 2417 200 mW Indoor + outdoor DFS + TPC 2457 11 2462 100 mW Indoor + outdoor 36 5180 200 mW Indoor only 48 5240 5260 5320 100 5500 11g 11n 11a 11n TPC 5580 132 5660 Kuwait 11g 11n 11a 11n TPC 5700 149 5745 11a 11n DFS + TPC 5825 2412 13 2472 149 5745 5805 2412 13 2472 36 5180 400 mW Indoor + outdoor 100 mW Indoor + outdoor 200 mW Indoor + outdoor 48 5240 52 5260 400 mW Indoor + outdoor 161 64 400 mW Indoor + outdoor 165 400 mW Indoor + outdoor 140 400 mW Indoor + outdoor 116 400 mW Indoor + outdoor 64 Korea 52 11a 11n 10 11a 11n Use 11a 11n PWR (EIRP) 200 mW Indoor + outdoor 5320 Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 29 ApprovalsforSCALANCEW780/W740802.11n 1.3 National approvals Country Mode Macau 11g 11n 13 2412 2472 100 mW Indoor + outdoor 11a 11n 149 161 5745 5805 100 mW Indoor + outdoor 11g 11n 13 2412 2472 100 mW Indoor + outdoor 11a 11n 5180 5240 200 mW Indoor only TPC 36 48 5260 5320 200 mW Indoor only DFS + TPC 52 64 100 5500 Madagascar CH 11a 11n MHz 5580 132 5660 Malaysia 11g 11n 5700 149 5745 11a 11n DFS 5825 2412 11a 11n 2472 56 5280 200 mW Indoor + outdoor 200 mW Indoor only 64 5320 149 5745 400 mW Indoor + outdoor 13 1000 mW Indoor + outdoor 165 1000 mW Indoor + outdoor 140 Use 116 11a 11n PWR (EIRP) 1000 mW Indoor + outdoor 165 5825 Morocco ♦ 11g 11n 13 2412 2472 100 mW Indoor only (only with SCALANCE W786-2IA RJ-45) 11a 11n 5180 5240 200 mW Indoor only TPC 36 48 5260 5320 200 mW Indoor only DFS + TPC 52 64 11a 11n Approvals SCALANCE W700 802.11n 30 Reference Manual, 01/2017, C79000-G8976-C392-05 ApprovalsforSCALANCEW780/W740802.11n 1.3 National approvals Country Mode Mexico 11g 11n CH 11a 11n MHz 2412 11 2462 36 5180 11g 11n 11a 11n TPC 5320 149 5745 11a 11n DFS + TPC 5825 2412 13 2472 36 5180 5240 52 5260 64 5320 5500 Oman 11g 11n 11a 11n TPC 5580 132 5660 11a 11n DFS + TPC 11a 11n 5700 2412 13 2472 36 5180 5240 52 5260 Pakistan 11g 11n 64 5320 5745 11a 11n 5825 2412 2472 149 5745 165 100 mW Indoor + outdoor 200 mW Indoor only 200 mW Indoor only 1000 mW Indoor + outdoor 100 mW Indoor + outdoor 13 1000 mW Indoor + outdoor 165 1000 mW Indoor + outdoor 149 200 mW Indoor only 48 200 mW Indoor only 140 100 mW Indoor + outdoor 116 1000 mW Indoor + outdoor 100 1000 mW Indoor + outdoor 48 500 mW Indoor + outdoor 165 Use 64 Mozambique PWR (EIRP) 100 mW Indoor + outdoor 5825 Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 31 ApprovalsforSCALANCEW780/W740802.11n 1.3 National approvals Country Mode Russia 11g 11n CH 11a 11n TPC 11a 11n DFS + TPC MHz 2412 13 2472 36 5180 5240 52 5260 Saudi Arabia 11g 11n 11a 11n TPC 5320 132 5660 11a 11n DFS + TPC 5700 149 5745 5825 2412 13 2472 36 5180 5240 52 5260 5320 100 5500 100 mW Indoor + outdoor 200 mW Indoor only 200 mW Indoor only 1000 mW Indoor + outdoor 116 5580 132 5660 100 mW Indoor + outdoor 64 140 100 mW Indoor + outdoor 48 100 mW Indoor + outdoor 165 100 mW Indoor + outdoor 140 100 mW Indoor + outdoor 64 Use 48 11a 11n PWR (EIRP) 1000 mW Indoor + outdoor 5700 Approvals SCALANCE W700 802.11n 32 Reference Manual, 01/2017, C79000-G8976-C392-05 ApprovalsforSCALANCEW780/W740802.11n 1.3 National approvals Country Mode Serbia 11g 11n CH Use 2412 2472 100 mW Indoor + outdoor 36 48 5180 5240 200 mW Indoor only TPC 52 64 5260 5320 200 mW Indoor only DFS + TPC 100 116 5500 5580 1000 mW Indoor + outdoor 132 140 5660 5700 1000 mW Indoor + outdoor 11g 11n 13 2412 2472 100 mW Indoor + outdoor 11a 11n 5180 5240 200 mW Indoor only TPC 36 48 52 64 5260 5320 200 mW Indoor only DFS + TPC 100 116 5500 5580 1000 mW Indoor + outdoor 132 140 5660 5700 1000 mW Indoor + outdoor 2412 100 mW Indoor + outdoor 11a 11n 11a 11n Singapore PWR (EIRP) 13 11a 11n South Africa MHz 11g 11n Philippines 11a 11n TPC 11a 11n DFS + TPC 13 2472 36 5180 48 5240 52 5260 200 mW Indoor + outdoor 200 mW Indoor + outdoor 64 5320 100 116 5500 5580 1000 mW Indoor + outdoor 132 140 5660 5700 1000 mW Indoor + outdoor Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 33 ApprovalsforSCALANCEW780/W740802.11n 1.3 National approvals Country Mode 11a 11n CH MHz 149 Taiwan 11g 11n 11a 11n DFS + TPC 11a 11n 11g 11n 11a 11n DFS + TPC 11a 11n 1000 mW Indoor + outdoor 5825 2412 100 mW Indoor + outdoor 2417 200 mW Indoor + outdoor 10 2457 11 2462 100 mW Indoor + outdoor 52 5260 400 mW Indoor + outdoor 64 5320 100 116 5500 5580 400 mW Indoor + outdoor 132 140 5660 5700 400 mW Indoor + outdoor 149 5745 400 mW Indoor + outdoor 165 5825 2412 11 2462 36 5180 11a 11n 5745 Use 165 Thailand PWR (EIRP) 200 mW Indoor only 48 5240 52 5260 100 mW Indoor + outdoor 400 mW Indoor + outdoor 64 5320 100 116 5500 5580 400 mW Indoor + outdoor 132 140 5660 5700 400 mW Indoor + outdoor 149 5745 400 mW Indoor + outdoor 165 5825 Approvals SCALANCE W700 802.11n 34 Reference Manual, 01/2017, C79000-G8976-C392-05 ApprovalsforSCALANCEW780/W740802.11n 1.3 National approvals Country Mode Ukraine 11g 11n CH 11a 11n TPC 11a 11n DFS + TPC MHz 2412 13 2472 36 5180 5240 52 5260 11g 11n 11a 11n 5320 100 5500 DFS + TPC 11a 11n TC 200 mW Indoor + outdoor 200 mW Indoor + outdoor 200 mW Indoor + outdoor 116 5580 132 5660 200 mW Indoor + outdoor 136 5680 2412 100 mW Indoor + outdoor 2417 200 mW Indoor + outdoor 10 2457 11 2462 100 mW Indoor + outdoor 36 5180 200 mW Indoor only 11a 11n 100 mW Indoor + outdoor 64 Use 48 Uruguay PWR (EIRP) 48 5240 52 5260 400 mW Indoor + outdoor 64 5320 100 116 5500 5580 400 mW Indoor + outdoor 132 140 5660 5700 400 mW Indoor + outdoor 149 5745 400 mW Indoor + outdoor 165 5825 Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 35 ApprovalsforSCALANCEW780/W740802.11n 1.3 National approvals Country Mode Venezuela 11g 11n CH 11a 11n MHz 2412 13 2472 36 5180 11a 11n DFS 11a 11n 5240 52 5260 11g 11n 11a 11n TPC 5320 149 5745 11a 11n DFS + TPC 5825 2412 2472 36 5180 5240 52 5260 5320 100 5500 200 mW Indoor only 200 mW Indoor only 1000 mW Indoor only 116 5580 132 5660 140 100 mW Indoor + outdoor 64 4000 mW Indoor + outdoor 48 1000 mW Indoor only 13 200 mW Indoor only 165 1000 mW Indoor + outdoor 64 Use 48 United Arab Emirates PWR (EIRP) 1000 mW Indoor only 5700 Approvals SCALANCE W700 802.11n 36 Reference Manual, 01/2017, C79000-G8976-C392-05 ApprovalsforSCALANCEW780/W740802.11n 1.3 National approvals Country Mode Bahamas 11g 11n CH Ecuador Canada MHz PWR (EIRP) Use 2412 100 mW Indoor + outdoor 2417 200 mW Indoor + outdoor Peru 10 2457 Puerto Rico 11 2462 100 mW Indoor + outdoor 36 5180 200 mW Indoor only USA 11a 11n 11a 11n DFS + TPC 11a 11n 48 5240 52 5260 11g 11n 11a 11n TPC 11a 11n DFS + TPC 5320 100 116 5500 5580 400 mW Indoor + outdoor 132 140 5660 5700 400 mW Indoor + outdoor 149 5745 400 mW Indoor + outdoor 165 5825 2412 13 2472 36 5180 5240 52 5260 5320 100 5500 5580 132 5660 1000 mW Indoor + outdoor 1000 mW Indoor + outdoor 140 5700 149 5745 165 200 mW Indoor only 116 200 mW Indoor only 64 100 mW Indoor + outdoor 48 11a 11n 400 mW Indoor + outdoor 64 Vietnam 400 mW Indoor + outdoor 5825 Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 37 ApprovalsforSCALANCEW780/W740802.11n 1.3 National approvals Approvals SCALANCE W700 802.11n 38 Reference Manual, 01/2017, C79000-G8976-C392-05 Approvals for SCALANCE W788C / W786C 802.11n Note Issued approvals on the type plate of the device The specified approvals apply only when the corresponding mark is printed on the product. You can check which of the following approvals have been granted for your product by the markings on the type plate. Range of validity The approvals listed in this section apply to the following products: Article number SCALANCE W786C-2 RJ-45 6GK5 786-2FC00-1AA0 SCALANCE W786C-2IA RJ-45 6GK5 786-2HC00-1AA0 SCALANCE W786C-2 SFP 6GK5 786-2FE00-1AA0 SCALANCE W788C-2 RJ-45 6GK5 788-2FC00-1AA0 SCALANCE W788C-2 M12 6GK5 788-2GD00-1AA0 SCALANCE W788C-2 M12 EEC 6GK5788-2GD00-1TA0 Article number Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 39 Approvals for SCALANCE W788C / W786C 802.11n 2.1 EC declaration of conformity 2.1 EC declaration of conformity The EC Declaration of Conformity is available for all responsible authorities at: Siemens Aktiengesellschaft Process Industries and Drives Division, Process Automation DE-76181 Karlsruhe Germany You will find the current EC declaration of conformity for these products on the Internet pages of Siemens Industry Online Support (hhttps://support.industry.siemens.com/cs/ww/en/ps/15853/cert). The SIMATIC NET products described in these Operating Instructions meet the requirements of the following EC directives: ● 94/9/EC Directive of the European Parliament and the Council of 23 March 1994 on the approximation of the laws of the Member States concerning equipment and protective systems intended for use in potentially explosive atmospheres (until 19.04.2016). ● 2014/34/EU Directive 2014/34/EU of the European Parliament and of the Council of 26 February 2014 on the harmonization of the laws of the Member States relating to equipment and protective systems intended for use in potentially explosive atmospheres official journal of the EU L96, 29/03/2014, pages. 309–356 (as of 20.04.2016) ● 1999/5/EC Directive of the European Parliament and of the Council of 1999 March 1999 on Radio Equipment and Telecommunications Terminal Equipment and the mutual recognition of their conformity (until 12.06.2016). ● 2014/53/EU Directive of the European Parliament and of the Council of April 16, 2014 on the harmonization of the laws of the member states relating to placing radio equipment on the market.; official journal of the EU L153, 22/05/2014, pages. 62–106 (as of 13.06.2016) ● 2011/65/EU (RoHS) RoHS directive of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment. ● 1999/519/EC Council recommendation on the limitation of exposure of the general public to electromagnetic fields (0 Hz to 300 GHz) Approvals SCALANCE W700 802.11n 40 Reference Manual, 01/2017, C79000-G8976-C392-05 Approvals for SCALANCE W788C / W786C 802.11n 2.1 EC declaration of conformity 2.1.1 ATEX ATEX directive (correct usage in potentially explosive atmospheres) The SIMATIC NET product meets the requirements of the EC directive:94/9/EC (until 19.04.2016) and 2014/34/EU (as of 20.04.2016) "Equipment and Protective Devices for Use in Potentially Explosive Atmospheres" according to the standards listed in the section Products (Page 43): Applied standard: EN 60079-0 + A11 Hazardous areas - Part 0: Equipment - General requirements EN 60079-15 Explosive atmospheres - Part 15: Equipment protection by type of protection "n" 2.1.2 RoHS RoHS directive (restriction of the use of certain hazardous substances) The SIMATIC NET products described in these operating instructions meet the requirements of the EC directive 2011/65/EC for the restriction of the use of certain hazardous substances in electrical and electronic equipment: Applied standard: EN 50581 Technical documentation for the assessment electrical and electronic products with respect to restriction of hazardous substances 2.1.3 R&TTE / RED 2.1.3.1 Protection of health and safety Article 3 (1) a) protection of health and safety EN 60950-1+A1+A2+A11+A12 Information technology equipment - Safety - Part 1: General requirements EN 62311 Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz – 300 GHz) Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 41 Approvals for SCALANCE W788C / W786C 802.11n 2.1 EC declaration of conformity 2.1.3.2 Efficient use of the radio spectrum Art. 3 (2) Efficient use of the radio spectrum 2.1.3.3 14 ETSI EN 301 328 Electromagnetic compatibility and radio spectrum matters (ERM) - wideband transmission systems - data transmission equipment operating in the 2.4 GHz ISM band and using wideband modulation techniques. Harmonized EN containing the essential requirements according to Article 3.2 of the R&TTE directive. 15 ETSI EN 301 893 Broadband Radio Access Networks (BRAN) - 5 GHz high performance RLAN Harmonized EN covering essential requirements of article 3.2 of the R&TTE Directive EMC Art. 3 (1) b - EMC EN 50121-3-2+AC Railway applications - Electromagnetic compatibility - part 3-2: Railway Vehicles Devices EN 50121-4+AC Railway applications - Electromagnetic compatibility - part 4: Interference emissions and immunity of signal telecommunications equipment ETSI EN 301 489-1 Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic compatibility for radio equipment and services - Part 1 : Common technical requirements ETSI EN 301 489-17 Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic compatibility for radio equipment and services - Part 17 : 10 EN 61000-6-1 Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments EN 61000-6-2+AC Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments EN 61000-6-3+A1+AC Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments EN 61000-6-4+A1 Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments 11 12 13 Approvals SCALANCE W700 802.11n 42 Reference Manual, 01/2017, C79000-G8976-C392-05 Approvals for SCALANCE W788C / W786C 802.11n 2.1 EC declaration of conformity 2.1.4 Products Product designation and standards The standards that apply to the product are described in RoHS (Page 41), ATEX (Page 41) and R&TTE / RED (Page 41). Product name Standards W786C-2 RJ45 1, 2 3, 4, 5, 8, 9, 10, 11, 12, 13, 14, 15, 16 W786C-2IA RJ45 W786-2 SFP W788C-2 RJ45 W788C-2 M12 W788C-2 M12 EEC 1, 2 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16 Certification ID The following tables show the product names and the corresponding certification ID: Type W786C-2 RJ-45 Number and type of Number of interthe Ethernet interfaces nal antennas Number of R-SMA sockets for external antennas Certification ID Article number Article number US variant 1 x RJ-45 EAPN-W2-RJ-E3 6GK5 786-2FC00-1AA0 W786C-2IA RJ-45 1 x RJ-45 EAPN-W2-RJ-I3 6GK5 786-2HC00-1AA0 W786-2 SFP EAPN-W2-SFP-E3 6GK5 786-2FE00-1AA0 2 x SFP Type Certification ID Article number: W788C-2 RJ-45 RAPN-W2-RJ-E3 6GK 5788-2FC00-1AA0 W788C-2 M12 RAPN-W2-M12-E3 6GK5 788-2GD00-1AA0 W788C-2 M12 EEC RAPN-W2-M12-E3 6GK5788-2GD00-1TA0 Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 43 Approvals for SCALANCE W788C / W786C 802.11n 2.2 General approvals 2.2 General approvals ATEX (explosion protection directive) WARNING When using SIMATIC NET products in hazardous area zone 2, make absolutely sure that the associated conditions in the following document are adhered to: "SIMATIC NET Product Information Use of subasseblies/modules in a Zone 2 Hazardous Area". You will find this document on the data medium that ships with some devices. on the Internet pages of Siemens Industry Online Support (http://support.automation.siemens.com/ww). Enter the document identification number C234 as the search term. The SIMATIC NET products meet the requirements of the EC directive 94/9/EC "Equipment and Protective Devices for Use in Potentially Explosive Atmospheres”. and as of 20.04.2016 the EC directive 2014/34/EU. ATEX classification: II 3 G Ex nA IIC T4 Gc KEMA 07ATEX0145 X The products meet the requirements of the following standards: ● EN 60079-15 (electrical apparatus for potentially explosive atmospheres; Type of protection "n") ● EN 60079-0 (Explosive atmospheres - Part 0: Equipment - General requirements) You will find the current versions of the standards in the currently valid ATEX certificates. Approvals SCALANCE W700 802.11n 44 Reference Manual, 01/2017, C79000-G8976-C392-05 Approvals for SCALANCE W788C / W786C 802.11n 2.2 General approvals IECEx The SIMATIC NET products meet the requirements of explosion protection according to IECEx. IECEx classification: Ex nA IIC T4 Gc DEK 14.0025X The products meet the requirements of the following standards: ● IEC 60079-15 (Explosive atmospheres - Part 15: Equipment protection by type of protection "n") ● IEC 60079-0 (Explosive atmospheres - Part 0: Equipment - General requirements) You will find the current versions of the standards in the currently valid IECEx certificates. FM The product meets the requirements of the standards: ● Factory Mutual Approval Standard Class Number 3611 ● FM Hazardous (Classified) Location Electrical Equipment: Non Incendive / Class I / Division 2 / Groups A,B,C,D / T4 and Non Incendive / Class I / Zone 2 / Group IIC / T4 cULus Approval Hazardous Location cULus Listed I. T. E. FOR HAZ. LOC. Underwriters Laboratories Inc. complying with ● UL 60950-1 (Information Technology Equipment) ● ANSI/ISA 12.12.01-2007 ● CSA C22.2 No. 213-M1987 Approved for use in Cl. 1, Div. 2, GP A, B, C, D T4 Cl. 1, Zone 2, GP IIC T4 Report no. E240480 Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 45 Approvals for SCALANCE W788C / W786C 802.11n 2.2 General approvals FCC approval This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Notice Changes or modifications made to this equipment not expressly approved by SIEMENS may void the FCC authorization to operate this equipment. IEEE 802.11b or g operation of this product in the USA is firmware-limited to channels 1 through 11. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ● Reorient or relocate the receiving antenna. ● Increase the separation between the equipment and receiver. ● Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ● Consult the dealer or an experienced radio/TV technician for help. Notice This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Professional Installation Notice: To comply with FCC part 15 rules in the United States, the system must be professionally installed to ensure compliance with the Part 15 certification. It is the responsibility of the operator and professional installer to ensure that only certified systems are deployed in the United States. The use of the system in any other combination (such as co-located antennas transmitting the same information) is expressly forbidden. Approvals SCALANCE W700 802.11n 46 Reference Manual, 01/2017, C79000-G8976-C392-05 Approvals for SCALANCE W788C / W786C 802.11n 2.2 General approvals Notice For use of DFS channels ● Use of the RCoax Cable Antenna 6XV1875-2D is not permitted in channels which require dynamic frequency selection (DFS). ● Any installation of either a master or a client device within 35 km of a TDWR (Terminal Doppler Weather Radar) location shall be separated by at least 30 MHz (center-to-center) from the TDWR operating frequency. These devices shall be registered in the industry sponsored WISPA database, http://udia.spectrumbridge.com/udia/home.aspx (http://udia.spectrumbridge.com/udia/home.aspx) When you open this link, you get the following choices: – "Search" opens a window with TDWR locations and frequencies. – "User Signup" allows you to register as user of the database. – After registering you can Logon and register your WLAN location. Please fill in all required information. For more information with respect to WISPA database and TWDR locations please consult FCC publication KDB 443999 D01. NEMA TS2 The product meets the requirements of the standard NEMA TS2 (Traffic Controller Assemblies with NTCIP Requirements) SCALANCE W788C-2 M12 EEC 6GK5788-2GD00-1TA0 RSS-247 of Industry Canada for SCALANCE W786-x This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. This radio transmitter (IC: 267AA-MPCIE1V1) has been approved by Industry Canada to operate with the antenna types listed in section 6.8 with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 47 Approvals for SCALANCE W788C / W786C 802.11n 2.2 General approvals To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that permitted for successful communication. That the device for the band 5150-5250 MHz is only for indoor usage to reduce potential for harmful interference to co-channel mobile satellite systems. Users should also be cautioned to take note that high power radars are allocated as primary users (meaning they have priority) of 5250-5350 MHz and 5650-5850 MHz and these radars could cause interference and/or damage to LE-LAN devices. This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. RSS-247 of Industry Canada for SCALANCE W7x8 This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. This radio transmitter (IC: 267AA-MPCIE1V1) has been approved by Industry Canada to operate with the antenna types listed in section 5.4 with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that permitted for successful communication. That the device for the band 5150-5250 MHz is only for indoor usage to reduce potential for harmful interference to co-channel mobile satellite systems. Users should also be cautioned to take note that high power radars are allocated as primary users (meaning they have priority) of 5250-5350 MHz and 5650-5850 MHz and these radars could cause interference and/or damage to LE-LAN devices. This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. Approvals SCALANCE W700 802.11n 48 Reference Manual, 01/2017, C79000-G8976-C392-05 Approvals for SCALANCE W788C / W786C 802.11n 2.2 General approvals Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Note for USA, Canada, Puerto Rico, Peru, Bahamas, Ecuador and Columbia When operating the SCALANCE W700 with DFS (Dynamic Frequence Selection), the IWLAN RCoax Cable 5 GHz (order number 6XV1875-2D) may not be used in the countries listed above. Approvals in Argentina Devices of the SCALANCE W786-x series are approved in Argentina under the following certification numbers: Certification ID Certification number EAPN-W1-RJ-E3 CNC: C-11549 EAPN-W2-RJ-E3 CNC: C-11536 EAPN-W2-RJ-I3 CNC: C-11564 EAPN-W2-SFP-E3 CNC: C-11547 Devices of the SCALANCE W788-x series are approved in Argentina under the following certification numbers: Certification ID Certification number RAPN-W1-RJ-E3 CNC: C-11541 RAPN-W2-RJ-E3 CNC: C-11502 RAPN-W1-M12-E3 CNC: C-11546 RAPN-W2-M12-E3 CNC: C-11548 Approval in Brazil From the SCALANCE W786-x series, the following devices are approved for Brazil: Type Order number EAPN number W786-1 RJ-45 6GK5 786-1FC00-0AA0 EAPN-W1-RJ-E3 W786-2 RJ-45 6GK5 786-2FC00-0AA0 EAPN-W2-RJ-E3 W786C-2 RJ-45 6GK5 786-2FC00-1AA0 EAPN-W2-RJ-E3 W786-2IA RJ-45 6GK5 786-2HC00-0AA0 EAPN-W2-RJ-I3 W786C-2IA RJ-45 6GK5 786-2HC00-1AA0 EAPN-W2-RJ-I3 W786-2 SFP 6GK5 786-2FE00-0AA0 EAPN-W2-SFP-E3 The listed devices are approved in Brazil under the following certification numbers: Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 49 Approvals for SCALANCE W788C / W786C 802.11n 2.2 General approvals Este equipamento opera em caráter secundário, isto, ist é, não tem direito à proteção contra interferência prejudicial, mesmo de estações do mesmo tipo e não pode causar interferência a sistemas operando em caráter primário. From the SCALANCE W7x8 series, the following devices are approved for Brazil: Type Order number RAPN number W788-1 RJ-45 6GK 5788-1FC00-0AA0 RAPN-W1-RJ-E3 W788-2 RJ-45 6GK5 788-2FC00-0AA0 RAPN-W2-RJ-E3 W788-1 M12 6GK5 788-1GD00-0AA0 RAPN-W1-M12-E3 W788-2 M12 6GK5 788-2GD00-0AA0 RAPN-W2-M12-E3 W788-2 M12 EEC 6GK5 788-2GD00-0TA0 RAPN-W2-M12-E3 W748-1 RJ-45 6GK5 748-1FC00-0AA0 RAPN-W1-RJ-E3 W748-1 M12 6GK5 748-1GD00-0AA0 RAPN-W1-M12-E3 W788C-2 RJ-45 6GK 5788-2FC00-1AA0 RAPN-W2-RJ-E3 W788C-2 M12 6GK5 788-2GD00-1AA0 RAPN-W2-M12-E3 W788C-2 M12 EEC 6GK5788-2GD00-1TA0 RAPN-W2-M12-E3 The listed devices are approved in Brazil under the following certification numbers: Este equipamento opera em caráter secundário, isto, ist é, não tem direito à proteção contra interferência prejudicial, mesmo de estações do mesmo tipo e não pode causar interferência a sistemas operando em caráter primário. Approval for Mexico The WLAN modules included in the devices have the following certification number: RCPSIMP12-0751 Approvals SCALANCE W700 802.11n 50 Reference Manual, 01/2017, C79000-G8976-C392-05 Approvals for SCALANCE W788C / W786C 802.11n 2.2 General approvals Approval for Oman Devices of the SCALANCE W786-x series are approved in Oman under the following certification numbers: OMAN-TRA R/1773/14 D090258 Devices of the SCALANCE W788-x series are approved in Oman under the following certification numbers: OMAN-TRA R/1772/14 D090258 Marking for the customs union EAC (Eurasian Conformity) Customs union of Russia, Belarus and Kazakhstan Declaration of the conformity according to the technical regulations of the customs union (TR CU) Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 51 Approvals for SCALANCE W788C / W786C 802.11n 2.3 National approvals 2.3 National approvals The national approval of the controller-based access points depends on the controller on which they are operated. The controllers are available in the following country-specific versions: ● Version for the USA and Canada (NAM) Article no. 6GK5 711-0XC00-1AB0 These countries are indicated in the table (NAM). ● Version for the Japan (JP) Article no. 6GK5 711-0XC00-1AD0 ● Version for countries outside Japan and NAM (RoW) Article no. 6GK5 711-0XC00-1AA0 The diamond symbol (♦) identifies all countries for which there was no approval at the time these operating instructions were written. The current status of the approvals can be found on the Internet at the following address: http://www.siemens.com/funkzulassungen Column Meaning Country Country Mode IEEE 802.11 standard and the TPC and / or DFS functionality, where required CH Channel MHz Frequency PWR (EIRP) Maximum permitted effective isotropic radiated power Use Permitted use indoors and / or outdoors Approvals SCALANCE W700 802.11n 52 Reference Manual, 01/2017, C79000-G8976-C392-05 Approvals for SCALANCE W788C / W786C 802.11n 2.3 National approvals Country Mode Andorra Belgium Bulgaria Denmark Germany Estonia Finland France Greece Great Britain Ireland Iceland Italy Croatia Latvia Liechtenstein Lithuania Luxembourg Malta Macedonia Monaco Montenegro Netherlands Norway Austria Poland Portugal Romania San Marino Sweden Switzerland Serbia Slovakia Slovenia Spain Czech Republic Turkey Hungary Vatican Cyprus 11g 11n Egypt 11g 11n CH MHz PWR (EIRP) Use 13 2412 2472 100 mW Indoor + outdoor 36 48 5180 5240 200 mW Indoor only TPC 52 64 5260 5320 200 mW Indoor only DFS + TPC 100 116 5500 5580 1000 mW Indoor + outdoor 132 140 5660 5700 1000 mW Indoor + outdoor 2412 100 mW Indoor + outdoor 11a 11n 11h 11n 11a 11n TPC 13 2472 36 5180 64 200 mW Indoor only 5320 Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 53 Approvals for SCALANCE W788C / W786C 802.11n 2.3 National approvals Country Mode Angola 11g 11n CH 11a 11n TPC 11h 11n DFS + TPC MHz 2412 13 2472 36 5180 5240 52 5260 11g 11n 11a 11n TPC 5320 100 5500 5580 132 5660 5700 2412 13 2472 36 5180 5240 52 5260 5320 100 5500 5600 132 5660 50 mW Indoor + outdoor 250 mW Indoor + outdoor 250 mW Indoor + outdoor 250 mW Indoor + outdoor 140 5700 149 5745 165 1000 mW Indoor + outdoor 120 1000 mW Indoor + outdoor 64 1000 mW Indoor + outdoor 48 200 mW Indoor only 140 200 mW Indoor only 116 100 mW Indoor + outdoor 64 Use 48 Argentina PWR (EIRP) 1000 mW Indoor + outdoor 5825 Approvals SCALANCE W700 802.11n 54 Reference Manual, 01/2017, C79000-G8976-C392-05 Approvals for SCALANCE W788C / W786C 802.11n 2.3 National approvals Country Mode Australia 11g 11n CH New Zealand 11a 11n TPC 11h 11n DFS + TPC 11a 11n TPC Bahrain 11g 11n MHz 2412 13 2472 36 5180 5240 52 5260 TPC 5320 149 5745 11h 11n DFS + TPC 5825 2412 11a 11n TPC Belarus 11g 11n 11a 11n TCP 11a 11n TCP + DFS 2472 36 5180 48 5240 5260 5320 149 5745 5825 2412 13 2472 36 5180 5240 52 5260 2000 mW Indoor + outdoor 100 mW Indoor + outdoor 100 mW Indoor + outdoor 100 mW Indoor + outdoor 64 5320 132 5660 140 200 mW Indoor only 48 200 mW Indoor only 165 100 mW Indoor + outdoor 64 400 mW Indoor + outdoor 52 200 mW Indoor only 13 200 mW Indoor only 165 100 mW Indoor + outdoor 64 Use 48 11a 11n PWR (EIRP) 100 mW Indoor + outdoor 5700 Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 55 Approvals for SCALANCE W788C / W786C 802.11n 2.3 National approvals Country Mode Brazil 11g 11n CH 11a 11n TPC MHz 2412 13 2472 36 5180 5320 100 5500 11g 11n 5700 149 5745 11a 11n TPC 5825 2412 11a 11n DFS + TPC 2472 36 5180 5240 52 5260 China 11g 11n 11a 11n TPC 5320 149 5745 5825 2412 13 2472 149 5745 100 mW Indoor only 100 mW Indoor only 100 mW Indoor only 165 165 100 mW Indoor only 64 4000 mW Indoor + outdoor 48 1000 mW Indoor + outdoor 13 200 mW Indoor only 165 4000 mW Indoor + outdoor 140 Use 64 Chile PWR (EIRP) 100 mW Indoor + outdoor 2000 mW Indoor + outdoor 5825 Approvals SCALANCE W700 802.11n 56 Reference Manual, 01/2017, C79000-G8976-C392-05 Approvals for SCALANCE W788C / W786C 802.11n 2.3 National approvals Country Mode Ivory Coast 11g 11n CH 11a 11n TPC 11a 11n DFS + TPC MHz 2412 13 2472 36 5180 5240 52 5260 11g 11n 11a 11n TPC 11a 11n DFS + TPC 5320 100 5500 5580 132 5660 200 mW Indoor only 1000 mW Indoor + outdoor 1000 mW Indoor + outdoor 140 5700 11 2412 2462 100 mW Indoor + outdoor 36 5180 200 mW Indoor only 48 5240 52 5260 400 mW Indoor + outdoor 64 5320 100 5500 400 mW Indoor + outdoor 116 5580 132 5660 TPC 200 mW Indoor only 116 11a 11n 100 mW Indoor + outdoor 64 Use 48 Guatemala PWR (EIRP) 400 mW Indoor + outdoor 140 5700 149 165 5745 5825 400 mW Indoor + outdoor Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 57 Approvals for SCALANCE W788C / W786C 802.11n 2.3 National approvals Country Mode Hong Kong 11g 11n CH 11a 11n TPC 11a 11n DFS + TPC MHz 2412 13 2472 36 5180 5240 52 5260 11g 11n 11a 11n TPC 5320 100 5500 11h 11n DFS + TPC 5580 132 5660 11a 11n 5700 2412 13 2472 36 5180 Indonesia ♦ 11g 11n 5240 52 5260 TPC 1000 mW Indoor + outdoor 100 mW Indoor + outdoor 200 mW Indoor only 200 mW Indoor only 64 5320 149 5745 200 mW Indoor + outdoor 165 5825 2412 100 mW Indoor + outdoor 2417 200 mW Indoor + outdoor 10 2457 11 2462 11a 11n 1000 mW Indoor + outdoor 48 200 mW Indoor only 140 200 mW Indoor only 116 100 mW Indoor + outdoor 64 Use 48 India PWR (EIRP) 13 2472 149 5745 161 100 mW Indoor + outdoor 400 mW Indoor + outdoor 5805 Approvals SCALANCE W700 802.11n 58 Reference Manual, 01/2017, C79000-G8976-C392-05 Approvals for SCALANCE W788C / W786C 802.11n 2.3 National approvals Country Mode Japan 11g 11n CH 11a TPC 11a 11n MHz 2412 13 2472 5040 12 5060 16 5080 36 5180 11h 11n DFS + TPC 5240 52 5260 TPC Qatar Kazakhstan 11g 11n 64 5320 5500 200 mW Indoor + outdoor 200 mW Indoor only 200 mW Indoor only 200 mW Indoor + outdoor 140 5799 184 4920 200 mW Indoor + outdoor 196 4980 2412 100 mW Indoor only 13 2472 11a 11n 149 165 5745 5825 100 mW Indoor only 11g 11n 2412 100 mW Indoor + outdoor 11a 11n TPC 11a 11n DFS + TPC 11g 11n 13 2472 36 5180 5240 52 5260 100 mW Indoor only 48 100 mW Indoor only 64 5320 132 5660 Colombia (NAM) 200 mW Indoor + outdoor 100 Use 48 11a PWR (EIRP) 100 mW Indoor + outdoor 140 5700 2412 100 mW Indoor + outdoor 2417 200 mW Indoor + outdoor 10 2457 11 2462 100 mW Indoor + outdoor Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 59 Approvals for SCALANCE W788C / W786C 802.11n 2.3 National approvals Country Mode CH 11a 11n MHz 36 TPC 11g 11n 11a 11n TPC Kuwait 11g 11n 5240 5745 TPC 5825 2412 13 2472 149 5745 11h 11n DFS + TPC 5805 2412 Macau 400 mW Indoor + outdoor 400 mW Indoor + outdoor 100 mW Indoor + outdoor 13 2472 36 5180 200 mW Indoor + outdoor 48 5240 52 5260 400 mW Indoor + outdoor 161 200 mW Indoor only 165 Use 48 11a 11n 5180 149 Korea PWR (EIRP) 200 mW Indoor + outdoor 64 5320 11g 11n 13 2412 2472 100 mW Indoor + outdoor 11a 11n 149 161 5745 5805 100 mW Indoor + outdoor TPC Approvals SCALANCE W700 802.11n 60 Reference Manual, 01/2017, C79000-G8976-C392-05 Approvals for SCALANCE W788C / W786C 802.11n 2.3 National approvals Country Mode Madagascar 11g 11n CH MHz 2412 2472 100 mW Indoor + outdoor 36 48 5180 5240 200 mW Indoor only TPC 52 64 5260 5320 200 mW Indoor only DFS + TPC 100 5500 11a 11n 11a 11n TPC 5580 132 5660 11g 11n 11h 11n DFS + TPC 11a 11n TPC 11g 11n 11a 11n DFS + TPC 11a 11n TPC 5700 149 5745 5825 2412 13 2472 56 5280 5320 149 5745 5825 2412 11 2462 52 5180 5320 149 5745 165 1000 mW Indoor + outdoor 500 mW Indoor + outdoor 1000 mW Indoor + outdoor 64 200 mW Indoor only 165 200 mW Indoor + outdoor 64 400 mW Indoor + outdoor 165 1000 mW Indoor + outdoor 140 1000 mW Indoor + outdoor 116 Mexico (NAM) Use 13 11a 11n Malaysia PWR (EIRP) 1000 mW Indoor + outdoor 5825 Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 61 Approvals for SCALANCE W788C / W786C 802.11n 2.3 National approvals Country Mode Mozambique 11g 11n CH 11a 11n TPC 11h 11n DFS + TPC MHz 2412 13 2472 36 5180 5240 52 5260 11g 11n 11a 11n TPC 5320 100 5500 11a 11n DFS + TPC 5580 132 5660 11a 11n TPC Pakistan 11g 11n 5700 2412 13 2472 36 5180 5240 52 5260 11a 11n TPC 5320 149 5745 5825 2412 200 mW Indoor only 200 mW Indoor only 1000 mW Indoor + outdoor 100 mW Indoor + outdoor 13 2472 149 5745 165 100 mW Indoor + outdoor 165 1000 mW Indoor + outdoor 64 1000 mW Indoor + outdoor 48 200 mW Indoor only 140 200 mW Indoor only 116 100 mW Indoor + outdoor 64 Use 48 Oman PWR (EIRP) 100 mW Indoor + outdoor 5825 Approvals SCALANCE W700 802.11n 62 Reference Manual, 01/2017, C79000-G8976-C392-05 Approvals for SCALANCE W788C / W786C 802.11n 2.3 National approvals Country Mode Russia 11g 11n CH 11a 11n TPC 11a 11n DFS + TPC MHz 2412 13 2472 36 5180 5240 52 5260 TPC Saudi Arabia 11g 11n 11a 11n TPC 5320 132 5660 11h 11n DFS + TPC 5700 149 5745 5825 2412 13 2472 36 5180 5240 52 5260 Singapore 11b 11g 11n Philippines ♦ 11a 11n TPC 5320 100 5500 11a 11n DFS + TPC 5580 132 5660 200 mW Indoor only 200 mW Indoor only 1000 mW Indoor + outdoor 1000 mW Indoor + outdoor 140 5700 2412 13 2472 36 5180 100 mW Indoor + outdoor 200 mW Indoor + outdoor 48 5240 52 5260 100 mW Indoor + outdoor 116 100 mW Indoor + outdoor 64 100 mW Indoor + outdoor 48 100 mW Indoor + outdoor 165 100 mW Indoor + outdoor 140 100 mW Indoor + outdoor 64 Use 48 11a 11n PWR (EIRP) 200 mW Indoor + outdoor 64 5320 100 116 5500 5580 1000 mW Indoor + outdoor Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 63 Approvals for SCALANCE W788C / W786C 802.11n 2.3 National approvals Country Mode CH 11a 11n TPC South Africa PWR (EIRP) Use 132 140 5660 5700 1000 mW Indoor + outdoor 149 5745 1000 mW Indoor + outdoor 165 5825 13 2412 2472 100 mW Indoor + outdoor 36 48 5180 5240 200 mW Indoor only TPC 52 64 5260 5320 200 mW Indoor only DFS + TPC 100 116 5500 5580 1000 mW Indoor + outdoor 132 140 5660 5700 1000 mW Indoor + outdoor 2412 100 mW Indoor + outdoor 2417 200 mW Indoor + outdoor 10 2457 11 2462 100 mW Indoor + outdoor 52 5260 400 mW Indoor + outdoor 11g 11n 11a 11n 11h 11n Taiwan ♦ MHz 11g 11n 11a 11n TPC 64 5320 100 5500 165 5825 Approvals SCALANCE W700 802.11n 64 Reference Manual, 01/2017, C79000-G8976-C392-05 Approvals for SCALANCE W788C / W786C 802.11n 2.3 National approvals Country Mode Thailand 11g 11n CH 11a 11n TPC 11a 11n DFS + TPC 11a 11n TPC Ukraine 11g 11n 11a 11n TPC 11h 11n DFS + TPC MHz PWR (EIRP) 2412 11 2462 36 5180 100 mW Indoor + outdoor 200 mW Indoor only 48 5240 52 5260 Use 400 mW Indoor + outdoor 64 5320 100 116 5500 5580 400 mW Indoor + outdoor 132 140 5660 5700 400 mW Indoor + outdoor 149 5745 400 mW Indoor + outdoor 165 5825 2412 13 2472 36 5180 5240 52 5260 5320 100 5500 5580 132 5660 200 mW Indoor + outdoor 116 136 200 mW Indoor + outdoor 64 200 mW Indoor + outdoor 48 100 mW Indoor + outdoor 200 mW Indoor + outdoor 5680 Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 65 Approvals for SCALANCE W788C / W786C 802.11n 2.3 National approvals Country Mode Uruguay 11g CH 11a MHz 2412 11a 11n 200 mW 5180 200 mW Indoor only 11g 11n 5240 149 5745 TPC 11a 11n DFS + TPC 11a 11n TPC 400 mW Indoor + outdoor 165 5825 2412 100 mW Indoor + outdoor 11 2462 200 mW 36 5180 200 mW Indoor only 48 5240 149 5745 5825 2412 2472 36 5180 5240 52 5260 64 5320 5745 1000 mW Indoor only 149 165 200 mW Indoor only 48 1000 mW Indoor + outdoor 13 400 mW Indoor + outdoor 165 11a 11n 48 Venezuela 2462 11a 11n 100 mW Indoor + outdoor 36 11n 11g Use 11 11a PWR (EIRP) 4000 mW Indoor + outdoor 5825 Approvals SCALANCE W700 802.11n 66 Reference Manual, 01/2017, C79000-G8976-C392-05 Approvals for SCALANCE W788C / W786C 802.11n 2.3 National approvals Country Mode United Arab Emirates 11g 11n CH 11a 11n TPC 11h 11n DFS + TPC MHz 2412 13 2472 36 5180 5240 52 5260 11g 11n Ecuador Canada (NAM) 100 mW Indoor + outdoor 200 mW Indoor only 200 mW Indoor only 64 5320 100 5500 1000 mW Indoor only 116 5580 132 5660 Use 48 Bahamas (NAM) PWR (EIRP) 1000 mW Indoor only 140 5700 2412 100 mW Indoor + outdoor 2417 200 mW Indoor + outdoor Peru 10 2457 Puerto Rico (NAM) 11 2462 100 mW Indoor + outdoor 52 5260 400 mW Indoor + outdoor USA (NAM) 11a 11n DFS + TPC 11a 11n TPC 64 5320 100 116 5500 5580 400 mW Indoor + outdoor 132 140 5660 5700 400 mW Indoor + outdoor 149 5745 400 mW Indoor + outdoor 165 5825 Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 67 Approvals for SCALANCE W788C / W786C 802.11n 2.3 National approvals Country Mode Vietnam 11g 11n CH 11a 11n TPC 11h 11n DFS + TPC MHz 2412 13 2472 36 5180 5240 52 5260 TPC 5320 100 5500 5580 132 5660 200 mW Indoor only 1000 mW Indoor + outdoor 1000 mW Indoor + outdoor 140 5700 149 5745 165 200 mW Indoor only 116 100 mW Indoor + outdoor 64 Use 48 11a 11n PWR (EIRP) 400 mW Indoor + outdoor 5825 Approvals SCALANCE W700 802.11n 68 Reference Manual, 01/2017, C79000-G8976-C392-05 Approvals for SCALANCE W770/W730 802.11n Note Issued approvals on the type plate of the device The specified approvals apply only when the corresponding mark is printed on the product. You can check which of the following approvals have been granted for your product by the markings on the type plate. Range of validity The approvals listed in this section apply to the following products: Article number Article number of the US version SCALANCE W774-1 RJ-45 6GK5774-1FX00-0AA0 6GK5774-1FX00-0AB0 SCALANCE W774-1 M12 EEC 6GK5774-1FY00-0TA0 6GK5774-1FY00-0TB0 SCALANCE W778-1 M12 6GK5778-1GY00-0AA0 6GK5778-1GY00-0AB0 SCALANCE W734-1 RJ-45 6GK5734-1FX00-0AA0 6GK5734-1FX00-0AB0 SCALANCE W738-1 M12 6GK5738-1GY00-0AA0 6GK5738-1GY00-0AB0 Access points Client module Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 69 Approvals for SCALANCE W770/W730 802.11n 3.1 EC declaration of conformity 3.1 EC declaration of conformity The EC Declaration of Conformity is available for all responsible authorities at: Siemens Aktiengesellschaft Process Industries and Drives Division, Process Automation DE-76181 Karlsruhe Germany You will find the current EC declaration of conformity for these products on the Internet pages of Siemens Industry Online Support (hhttps://support.industry.siemens.com/cs/ww/en/ps/15853/cert). The SIMATIC NET products described in these Operating Instructions meet the requirements of the following EC directives: ● 94/9/EC Directive of the European Parliament and the Council of 23 March 1994 on the approximation of the laws of the Member States concerning equipment and protective systems intended for use in potentially explosive atmospheres (until 19.04.2016). ● 2014/34/EU Directive 2014/34/EU of the European Parliament and of the Council of 26 February 2014 on the harmonization of the laws of the Member States relating to equipment and protective systems intended for use in potentially explosive atmospheres official journal of the EU L96, 29/03/2014, pages. 309–356 (as of 20.04.2016) ● 1999/5/EC Directive of the European Parliament and of the Council of 1999 March 1999 on Radio Equipment and Telecommunications Terminal Equipment and the mutual recognition of their conformity (until 12.06.2016). ● 2014/53/EU Directive of the European Parliament and of the Council of April 16, 2014 on the harmonization of the laws of the member states relating to placing radio equipment on the market.; official journal of the EU L153, 22/05/2014, pages. 62–106 (as of 13.06.2016) ● 2011/65/EU (RoHS) RoHS directive of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment. ● 1999/519/EC Council recommendation on the limitation of exposure of the general public to electromagnetic fields (0 Hz to 300 GHz) Approvals SCALANCE W700 802.11n 70 Reference Manual, 01/2017, C79000-G8976-C392-05 Approvals for SCALANCE W770/W730 802.11n 3.1 EC declaration of conformity 3.1.1 ATEX ATEX directive (correct usage in potentially explosive atmospheres) The SIMATIC NET product meets the requirements of the EC directive:94/9/EC (until 19.04.2016) and 2014/34/EU (as of 20.04.2016) "Equipment and Protective Devices for Use in Potentially Explosive Atmospheres" according to the standards listed in the section Products W770/W730 (Page 73): Applied standard: EN 60079-0 + A11 Hazardous areas - Part 0: Equipment - General requirements EN 60079-15 Explosive atmospheres - Part 15: Equipment protection by type of protection "n" 3.1.2 RoHS RoHS directive (restriction of the use of certain hazardous substances) The SIMATIC NET products described in these operating instructions meet the requirements of the EC directive 2011/65/EC for the restriction of the use of certain hazardous substances in electrical and electronic equipment: Applied standard: EN 50581 Technical documentation for the assessment electrical and electronic products with respect to restriction of hazardous substances 3.1.3 R&TTE / RED 3.1.3.1 Protection of health and safety Article 3 (1) a) protection of health and safety EN 60950-1+A1+A2+A11+A12 Information technology equipment - Safety - Part 1: General requirements EN 62311 Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz – 300 GHz) Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 71 Approvals for SCALANCE W770/W730 802.11n 3.1 EC declaration of conformity 3.1.3.2 EMC Art. 3 (1) b - EMC EN 50121-3-2+AC Railway applications - Electromagnetic compatibility - part 3-2: Railway Vehicles Devices EN 50121-4+AC Railway applications - Electromagnetic compatibility - part 4: Interference emissions and immunity of signal telecommunications equipment ETSI EN 301 489-1 Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic compatibility for radio equipment and services - Part 1 : Common technical requirements ETSI EN 301 489-17 10 11 12 13 3.1.3.3 Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic compatibility for radio equipment and services - Part 17 : EN 61000-6-1 Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments EN 61000-6-2+AC Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments EN 61000-6-3+A1+AC Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments EN 61000-6-4+A1 Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments Efficient use of the radio spectrum Art. 3 (2) Efficient use of the radio spectrum 14 ETSI EN 301 328 Electromagnetic compatibility and radio spectrum matters (ERM) - wideband transmission systems - data transmission equipment operating in the 2.4 GHz ISM band and using wideband modulation techniques. Harmonized EN containing the essential requirements according to Article 3.2 of the R&TTE directive. 15 ETSI EN 301 893 Broadband Radio Access Networks (BRAN) - 5 GHz high performance RLAN Harmonized EN covering essential requirements of article 3.2 of the R&TTE Directive Approvals SCALANCE W700 802.11n 72 Reference Manual, 01/2017, C79000-G8976-C392-05 Approvals for SCALANCE W770/W730 802.11n 3.1 EC declaration of conformity 3.1.4 Products W770/W730 CE conformity The standards that apply to the product are described in ATEX (Page 71), RoHS (Page 71) and R&TTE / RED (Page 71) Product name Standards W774-1 RJ45 1, 2 ,3, 4, 5, 8, 9, 10, 11, 12, 13, 14, 15 W734-1 RJ45 W774-1 M12 EEC 1, 2 ,3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15 W778-1 M12 3, 4, 5, 8, 9, 10, 11, 12, 13, 14, 15 W738-1 M12 Certification ID The following table shows the product names and the corresponding certification ID: Type Certification ID Article number Article number US variant W774-1 RJ-45 MSN-W1-RJ-E2 6GK5774-1FX00-0AA0 6GK5774-1FX00-0AB0 W774-1 M12 EEC MSN-W1-M12-E2 6GK5774-1FY00-0TA0 6GK5774-1FY00-0TB0 W734-1 RJ-45 MSN-W1-RJ-E2 6GK5734-1FX00-0AA0 6GK5734-1FX00-0AB0 W778-1 M12 MSN65-W1-M12-E2 6GK5778-1GY00-0AA0 6GK5778-1GY00-0AB0 W738-1 M12 MSN65-W1-M12-E2 6GK5738-1GY00-0AA0 6GK5738-1GY00-0AB0 Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 73 Approvals for SCALANCE W770/W730 802.11n 3.2 General approvals 3.2 General approvals ATEX (explosion protection directive) WARNING When using SIMATIC NET products in hazardous area zone 2, make absolutely sure that the associated conditions in the following document are adhered to: "SIMATIC NET Product Information Use of subasseblies/modules in a Zone 2 Hazardous Area". You will find this document on the data medium that ships with some devices. on the Internet pages of Siemens Industry Online Support (http://support.automation.siemens.com/ww). Enter the document identification number C234 as the search term. The SIMATIC NET products meet the requirements of the EC directive 94/9/EC "Equipment and Protective Devices for Use in Potentially Explosive Atmospheres”. and as of 20.04.2016 the EC directive 2014/34/EU. ATEX classification: II 3 G Ex nA IIC T4 Gc KEMA 07ATEX0145 X The products meet the requirements of the following standards: ● EN 60079-15 (electrical apparatus for potentially explosive atmospheres; Type of protection "n") ● EN 60079-0 (Explosive atmospheres - Part 0: Equipment - General requirements) You will find the current versions of the standards in the currently valid ATEX certificates. Approvals SCALANCE W700 802.11n 74 Reference Manual, 01/2017, C79000-G8976-C392-05 Approvals for SCALANCE W770/W730 802.11n 3.2 General approvals IECEx The SIMATIC NET products meet the requirements of explosion protection according to IECEx. IECEx classification: Ex nA IIC T4 Gc DEK 14.0025X The products meet the requirements of the following standards: ● IEC 60079-15 (Explosive atmospheres - Part 15: Equipment protection by type of protection "n") ● IEC 60079-0 (Explosive atmospheres - Part 0: Equipment - General requirements) You will find the current versions of the standards in the currently valid IECEx certificates. FM The product meets the requirements of the standards: ● Factory Mutual Approval Standard Class Number 3611 ● FM Hazardous (Classified) Location Electrical Equipment: Non Incendive / Class I / Division 2 / Groups A,B,C,D / T4 and Non Incendive / Class I / Zone 2 / Group IIC / T4 cULus Approval Hazardous Location cULus Listed I. T. E. FOR HAZ. LOC. Underwriters Laboratories Inc. complying with ● UL 60950-1 (Information Technology Equipment) ● ANSI/ISA 12.12.01-2007 ● CSA C22.2 No. 213-M1987 Approved for use in Cl. 1, Div. 2, GP A, B, C, D T4 Cl. 1, Zone 2, GP IIC T4 Report no. E240480 Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 75 Approvals for SCALANCE W770/W730 802.11n 3.2 General approvals FCC approval This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Notice Changes or modifications made to this equipment not expressly approved by SIEMENS may void the FCC authorization to operate this equipment. IEEE 802.11b or g operation of this product in the USA is firmware-limited to channels 1 through 11. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ● Reorient or relocate the receiving antenna. ● Increase the separation between the equipment and receiver. ● Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ● Consult the dealer or an experienced radio/TV technician for help. Notice This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Professional Installation Notice: To comply with FCC part 15 rules in the United States, the system must be professionally installed to ensure compliance with the Part 15 certification. It is the responsibility of the operator and professional installer to ensure that only certified systems are deployed in the United States. The use of the system in any other combination (such as co-located antennas transmitting the same information) is expressly forbidden. Approvals SCALANCE W700 802.11n 76 Reference Manual, 01/2017, C79000-G8976-C392-05 Approvals for SCALANCE W770/W730 802.11n 3.2 General approvals Notice For use of DFS channels ● Use of the RCoax Cable Antenna 6XV1875-2D is not permitted in channels which require dynamic frequency selection (DFS). ● Any installation of either a master or a client device within 35 km of a TDWR (Terminal Doppler Weather Radar) location shall be separated by at least 30 MHz (center-to-center) from the TDWR operating frequency. These devices shall be registered in the industry sponsored WISPA database, http://udia.spectrumbridge.com/udia/home.aspx (http://udia.spectrumbridge.com/udia/home.aspx) When you open this link, you get the following choices: – "Search" opens a window with TDWR locations and frequencies. – "User Signup" allows you to register as user of the database. – After registering you can Logon and register your WLAN location. Please fill in all required information. For more information with respect to WISPA database and TWDR locations please consult FCC publication KDB 443999 D01. Notice In order to comply with FCC/ISED/MIC RF Exposure requirements, this device must be installed to provide at least 20 cm separation from the human body at all times. CSA Information Technology Equipment CSA Certification Mark Canadian Standard Association CSA C22.2 No. 60950-1-03 RSS-247 of Industry Canada This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. This radio transmitter (IC: 267AA-ELN1V1 for W760/W720 802.11n and IC: 267AA-MSN1V1 for W774/W734 802.11n) has been approved by Industry Canada to operate with the antenna types listed in section 5.6 with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that permitted for successful communication. Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 77 Approvals for SCALANCE W770/W730 802.11n 3.2 General approvals That the device for the band 5150-5250 MHz is only for indoor usage to reduce potential for harmful interference to co-channel mobile satellite systems. Users should also be cautioned to take note that high power radars are allocated as primary users (meaning they have priority) of 5250-5350 MHz and 5650-5850 MHz and these radars could cause interference and/or damage to LE-LAN devices. This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled environment. In order to comply with FCC/ISED/MIC RF Exposure requirements, this device must be installed to provide at least 20 cm separation from the human body at all times. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Afin de se conformer aux exigences d'exposition RF MIC / FCC / ISED, cet appareil doit être installé pour fournir au moins 20 cm de séparation du corps humain en tout temps RCM The product meets the requirements of the AS/NZS 2064 standard (Class A). Approvals for Argentina Devices of the SCALANCE W760/W720 series are approved in Argentina under the following certification number: Certification ID Certification number ELN-W1-RJ-E1 CNC: C-13172 Devices of the SCALANCE W770/W730 series are approved in Argentina under the following certification numbers: Certification ID Certification number MSN-W1-RJ-E2 CNC: C-13164 MSN-W1-M12-E2 CNC: C-13163 Approval for Brazil Devices of the SCALANCE W760/W720 series are approved in Brazil under the following certification numbers: Este equipamento opera em caráter secundário, isto, ist é, não tem direito à proteção contra interferência prejudicial, mesmo de estações do mesmo tipo e não pode causar interferência a sistemas operando em caráter primário. Approvals SCALANCE W700 802.11n 78 Reference Manual, 01/2017, C79000-G8976-C392-05 Approvals for SCALANCE W770/W730 802.11n 3.2 General approvals Devices of the SCALANCE W770/W730 series are approved in Brazil under the following certification numbers: Este equipamento opera em caráter secundário, isto, ist é, não tem direito à proteção contra interferência prejudicial, mesmo de estações do mesmo tipo e não pode causar interferência a sistemas operando em caráter primário. KCC Statement (Republic of Korea) 사용자안내문(제5조제1항제1호관련) 기종별 A 급 기기급 기기 (업무용 방송통신기기) 사용자안내문 이 기기는 업무용(A 급)으로 전자파적합등록을 한(A 급)으로 전자파적합등록을 한 기기이오니 판매자 또는 사용자는 이 점을 주의하시기 바라며, 가정외의 지역에서 사용하는 것을 목적으로 합니다. "당해 무선설비는 전파혼신 가능성이 있으므로 인명안전과 관련된 서비스는 할 수 없음" Marking for the customs union EAC (Eurasian Conformity) Customs union of Russia, Belarus and Kazakhstan Declaration of the conformity according to the technical regulations of the customs union (TR CU) Railway approval for the SCALANCE W774-1 M12 EEC The SCALANCE W774-1 M12 EEC device meets the requirements of the railway standard EN 50155:2007 "Railway Applications - Electronic equipment used on rolling stock". Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 79 Approvals for SCALANCE W770/W730 802.11n 3.3 SCALANCE W774/734 national approvals 3.3 SCALANCE W774/734 national approvals The following table lists the countries in which the SCALANCE W700 product is approved. The diamond symbol (♦) identifies all countries for which there was no approval at the time these operating instructions were written. The current status of the approvals can be found on the Internet at the following address: http://www.siemens.com/funkzulassungen Column Meaning Country Country Mode IEEE 802.11 standard and the TPC and / or DFS functionality, where required CH Channel MHz Frequency PWR (EIRP) Maximum permitted effective isotropic radiated power Use Permitted use indoors and / or outdoors Approvals SCALANCE W700 802.11n 80 Reference Manual, 01/2017, C79000-G8976-C392-05 Approvals for SCALANCE W770/W730 802.11n 3.3 SCALANCE W774/734 national approvals Country Mode Andorra Belgium Bosnia and Herzegovina Bulgaria Denmark Germany Estonia Finland France Greece Great Britain Ireland Iceland Italy Croatia Latvia Liechtenstein Lithuania Luxembourg Malta Macedonia Monaco Montenegro Netherlands Norway Austria Poland Portugal Romania San Marino Sweden Switzerland Slovakia Slovenia Spain Czech Republic Turkey Hungary Vatican Cyprus 11g 11n Egypt CH MHz PWR (EIRP) Use 13 2412 2472 100 mW Indoor + outdoor 36 48 5180 5240 200 mW Indoor only TPC 52 64 5260 5320 200 mW Indoor only DFS + TPC 100 116 5500 5580 1000 mW Indoor + outdoor 132 140 5660 5700 1000 mW Indoor + outdoor 11a 11n 149 165 5745 5825 25 mW Indoor + outdoor 11g 11n 2412 100 mW Indoor + outdoor 11a 11n 11a 11n 11a 11n TPC 13 2472 36 5180 64 200 mW Indoor only 5320 Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 81 Approvals for SCALANCE W770/W730 802.11n 3.3 SCALANCE W774/734 national approvals Country Mode Angola 11g 11n CH 11a 11n TPC 11a 11n DFS + TPC MHz 2412 13 2472 36 5180 5240 52 5260 11g 11n 11a 11n 5320 100 5500 11a 11n TPC 5580 132 5660 5700 2412 13 2472 36 5180 5240 52 5260 11a 11n 5320 100 5500 5600 132 5660 50 mW Indoor + outdoor 250 mW Indoor + outdoor 250 mW Indoor + outdoor 250 mW Indoor + outdoor 140 5700 149 5745 165 1000 mW Indoor + outdoor 120 1000 mW Indoor + outdoor 64 1000 mW Indoor + outdoor 48 200 mW Indoor only 140 200 mW Indoor only 116 100 mW Indoor + outdoor 64 Use 48 Argentina PWR (EIRP) 1000 mW Indoor + outdoor 5825 Approvals SCALANCE W700 802.11n 82 Reference Manual, 01/2017, C79000-G8976-C392-05 Approvals for SCALANCE W770/W730 802.11n 3.3 SCALANCE W774/734 national approvals Country Mode Australia 11g 11n CH New Zealand 11a 11n MHz 2412 13 2472 36 5180 11a 11n DFS + TPC 11a 11n 5240 52 5260 11g 11n 11a 11n 5320 149 5745 11a 11n DFS + TPC 5825 2412 11a 11n 2472 36 5180 Belarus 11g 11n 11a 11n TCP 48 5240 5260 11a 11n TCP + DFS 5320 149 5745 5825 2412 13 2472 36 5180 5240 52 5260 2000 mW Indoor + outdoor 100 mW Indoor + outdoor 100 mW Indoor + outdoor 100 mW Indoor + outdoor 64 5320 132 5660 140 200 mW Indoor only 48 200 mW Indoor only 165 100 mW Indoor + outdoor 64 400 mW Indoor + outdoor 52 200 mW Indoor only 13 200 mW Indoor only 165 100 mW Indoor + outdoor 64 Use 48 Bahrain PWR (EIRP) 100 mW Indoor + outdoor 5700 Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 83 Approvals for SCALANCE W770/W730 802.11n 3.3 SCALANCE W774/734 national approvals Country Mode Brazil 11g 11n CH 11a 11n MHz 2412 13 2472 36 5180 11a 11n TPC 5240 52 5260 Chile 11g 11n 11a 11n TPC 5320 100 5500 11a 11n DFS + TPC 5700 149 5745 11a 11n DFS China 11g 11n 5825 2412 13 2472 36 5180 5240 52 5260 11a 11n TPC 5320 149 5745 11a 11n DFS + TPC 5825 2412 11a 11n 2472 36 5180 5240 52 5260 100 mW Indoor only 100 mW Indoor + outdoor 200 mW Indoor only 200 mW Indoor only 64 5320 149 5745 100 mW Indoor only 48 165 100 mW Indoor only 13 100 mW Indoor only 165 4000 mW Indoor + outdoor 64 1000 mW Indoor + outdoor 48 200 mW Indoor only 165 200 mW Indoor only 140 4000 mW Indoor + outdoor 64 Use 48 11a 11n PWR (EIRP) 2000 mW Indoor + outdoor 5825 Approvals SCALANCE W700 802.11n 84 Reference Manual, 01/2017, C79000-G8976-C392-05 Approvals for SCALANCE W770/W730 802.11n 3.3 SCALANCE W774/734 national approvals Country Mode Ivory Coast 11g 11n CH 11a 11n TPC 11a 11n DFS + TPC MHz 2412 13 2472 36 5180 5240 52 5260 11g 11n 11a 11n 5320 100 5500 DFS + TPC 5580 132 5660 200 mW Indoor only 1000 mW Indoor + outdoor 1000 mW Indoor + outdoor 140 5700 2412 100 mW Indoor + outdoor 2417 200 mW Indoor + outdoor 10 2457 11 2462 100 mW Indoor + outdoor 36 5180 200 mW Indoor only 48 5240 52 5260 5320 100 5500 400 mW Indoor + outdoor 116 5580 132 5660 400 mW Indoor + outdoor 64 Hong Kong 200 mW Indoor only 116 11a 11n 100 mW Indoor + outdoor 64 Use 48 Guatemala PWR (EIRP) 400 mW Indoor + outdoor 140 5700 11a 11n 149 165 5745 5825 400 mW Indoor + outdoor 11g 11n 2412 100 mW Indoor + outdoor 11a 11n TPC 13 2472 36 5180 48 200 mW Indoor only 5240 Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 85 Approvals for SCALANCE W770/W730 802.11n 3.3 SCALANCE W774/734 national approvals Country Mode CH 11a 11n MHz 52 DFS + TPC 11a 11n TPC 5320 5500 11a 11n DFS + TPC 5580 132 5660 11a 11n 5700 2412 13 2472 36 5180 Indonesia 11g 11n 11a 11n 5240 52 5260 64 5320 5745 200 mW Indoor only 200 mW Indoor only 200 mW Indoor + outdoor 165 5825 2412 13 2472 149 5745 161 100 mW Indoor + outdoor 149 1000 mW Indoor + outdoor 48 1000 mW Indoor + outdoor 140 200 mW Indoor only 116 Use 64 11g 11n 5260 100 India PWR (EIRP) 100 mW Indoor + outdoor 400 mW Indoor + outdoor 5805 Approvals SCALANCE W700 802.11n 86 Reference Manual, 01/2017, C79000-G8976-C392-05 Approvals for SCALANCE W770/W730 802.11n 3.3 SCALANCE W774/734 national approvals Country Mode Japan 11g 11n CH MHz 2412 2472 16 5040 5080 200 mW Indoor + outdoor 11a 11n 36 5180 200 mW Indoor only DFS + TPC 11a 11g 11n 5240 52 5260 TPC 11a 11n DFS + TPC 5320 100 5500 200 mW Indoor + outdoor 140 5700 184 196 4920 4980 200 mW Indoor + outdoor 2412 100 mW Indoor + outdoor 13 2472 36 5180 5240 52 5260 100 mW Indoor only 48 100 mW Indoor only 64 5320 132 5660 11g 11n 200 mW Indoor only 64 11a 11n 48 Colombia 200 mW Indoor + outdoor 13 11a 11n Qatar Use 11a Kazakhstan PWR (EIRP) 100 mW Indoor + outdoor 140 5700 2412 100 mW Indoor only 13 2472 11a 11n 149 165 5745 5825 100 mW Indoor only 11g 11n 2412 100 mW Indoor + outdoor 11a 11n 11 2462 36 5180 48 200 mW Indoor only 5240 Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 87 Approvals for SCALANCE W770/W730 802.11n 3.3 SCALANCE W774/734 national approvals Country Mode CH 11a 11n MHz 52 DFS + TPC 5320 5500 11g 11n 5580 132 5660 11a 11n TPC 5700 149 5745 Kuwait 11g 11n 5825 2412 11a 11n TPC 2472 149 5745 11a 11n DFS + TPC 5805 2412 Macau Madagascar 400 mW Indoor + outdoor 100 mW Indoor + outdoor 13 2472 36 5180 200 mW Indoor + outdoor 48 5240 52 5260 400 mW Indoor + outdoor 161 400 mW Indoor + outdoor 13 400 mW Indoor + outdoor 165 400 mW Indoor + outdoor 140 400 mW Indoor + outdoor 116 Use 64 Korea 5260 100 11a 11n PWR (EIRP) 200 mW Indoor + outdoor 64 5320 11g 11n 13 2412 2472 100 mW Indoor + outdoor 11a 11n 149 161 5745 5805 100 mW Indoor + outdoor 11g 11n 13 2412 2472 100 mW Indoor + outdoor 36 48 5180 5240 200 mW Indoor only TPC 52 64 5260 5320 200 mW Indoor only DFS + TPC 11a 11n 11a 11n Approvals SCALANCE W700 802.11n 88 Reference Manual, 01/2017, C79000-G8976-C392-05 Approvals for SCALANCE W770/W730 802.11n 3.3 SCALANCE W774/734 national approvals Country Mode CH MHz 100 11g 11n 11a 11n DFS 5580 5660 11a 11n 5700 149 5745 Mexico 11g 11n 5825 2412 13 2472 56 5280 11a 11n 5320 149 5745 5825 2412 Pakistan 11g 11n 2462 36 5180 11a 11n 5320 149 5745 5825 2412 1000 mW Indoor + outdoor 1000 mW Indoor + outdoor 100 mW Indoor + outdoor 13 2472 149 5745 165 500 mW Indoor + outdoor 165 1000 mW Indoor + outdoor 64 200 mW Indoor only 11 200 mW Indoor + outdoor 165 400 mW Indoor + outdoor 64 1000 mW Indoor + outdoor 165 1000 mW Indoor + outdoor 140 Use 132 Malaysia 5500 116 11a 11n PWR (EIRP) 100 mW Indoor + outdoor 5825 Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 89 Approvals for SCALANCE W770/W730 802.11n 3.3 SCALANCE W774/734 national approvals Country Mode Russia 11g 11n CH 11a 11n TPC 11a 11n DFS + TPC MHz 2412 13 2472 36 5180 5240 52 5260 11g 11n 11a 11n TPC 5320 132 5660 11a 11n DFS + TPC 5700 2412 2472 36 5180 5240 52 5260 Serbia 100 mW Indoor + outdoor 200 mW Indoor only 200 mW Indoor only 64 5320 100 5500 1000 mW Indoor + outdoor 116 5580 132 5660 100 mW Indoor + outdoor 48 100 mW Indoor + outdoor 13 100 mW Indoor + outdoor 140 100 mW Indoor + outdoor 64 Use 48 Saudi Arabia PWR (EIRP) 1000 mW Indoor + outdoor 140 5700 11g 11n 13 2412 2472 100 mW Indoor + outdoor 11a 11n 5180 5240 200 mW Indoor only TPC 36 48 52 64 5260 5320 200 mW Indoor only DFS + TPC 100 116 5500 5580 1000 mW Indoor + outdoor 132 140 5660 5700 1000 mW Indoor + outdoor 11a 11n Approvals SCALANCE W700 802.11n 90 Reference Manual, 01/2017, C79000-G8976-C392-05 Approvals for SCALANCE W770/W730 802.11n 3.3 SCALANCE W774/734 national approvals Country Mode South Africa 11g 11n CH PWR (EIRP) Use 13 2412 2472 100 mW Indoor + outdoor 36 48 5180 5240 200 mW Indoor only TPC 52 64 5260 5320 200 mW Indoor only DFS + TPC 100 116 5500 5580 1000 mW Indoor + outdoor 132 140 5660 5700 1000 mW Indoor + outdoor 2412 100 mW Indoor + outdoor 11a 11n 11a 11n Singapore MHz 11g 11n Philippines 11a 11n TPC 11a 11n DFS + TPC 11a 11n 13 2472 36 5180 48 5240 52 5260 200 mW Indoor + outdoor 200 mW Indoor + outdoor 64 5320 100 116 5500 5580 1000 mW Indoor + outdoor 132 140 5660 5700 1000 mW Indoor + outdoor 149 5745 1000 mW Indoor + outdoor 165 5825 Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 91 Approvals for SCALANCE W770/W730 802.11n 3.3 SCALANCE W774/734 national approvals Country Mode Taiwan 11g 11n CH 11a 11n DFS + TPC 11a 11n MHz 11g 11n 2412 100 mW Indoor + outdoor 2417 200 mW Indoor + outdoor 10 2457 11 2462 100 mW Indoor + outdoor 52 5260 400 mW Indoor + outdoor 64 5320 5500 5580 400 mW Indoor + outdoor 132 140 5660 5700 400 mW Indoor + outdoor 149 5745 400 mW Indoor + outdoor DFS 11a 11n 165 5825 2412 2472 36 5180 5240 52 5260 5320 149 5745 1000 mW Indoor only 64 165 200 mW Indoor only 48 1000 mW Indoor + outdoor 13 11a 11n 100 116 11a 11n Use Venezuela PWR (EIRP) 4000 mW Indoor + outdoor 5825 Approvals SCALANCE W700 802.11n 92 Reference Manual, 01/2017, C79000-G8976-C392-05 Approvals for SCALANCE W770/W730 802.11n 3.3 SCALANCE W774/734 national approvals Country Mode United Arab Emirates 11g 11n CH 11a 11n TPC 11a 11n DFS + TPC MHz 2412 13 2472 36 5180 5240 52 5260 11g 11n Canada Colombia Peru 11a 11n Puerto Rico 5320 100 5500 USA Uruguay 11a 11n DFS + TPC 5580 132 5660 11a 11n 200 mW Indoor only 1000 mW Indoor only 1000 mW Indoor only 140 5700 2412 11 2462 36 5180 100 mW Indoor + outdoor 200 mW Indoor only 48 5240 52 5260 200 mW Indoor only 116 Thailand 100 mW Indoor + outdoor 64 Use 48 Bahamas PWR (EIRP) 400 mW Indoor + outdoor 64 5320 100 116 5500 5580 400 mW Indoor + outdoor 132 140 5660 5700 400 mW Indoor + outdoor 149 5745 400 mW Indoor + outdoor 165 5825 Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 93 Approvals for SCALANCE W770/W730 802.11n 3.3 SCALANCE W774/734 national approvals Country Mode Vietnam 11g 11n CH 11a 11n TPC 11a 11n DFS + TPC MHz 2412 13 2472 36 5180 5240 52 5260 5320 100 5500 5580 132 5660 200 mW Indoor only 1000 mW Indoor + outdoor 1000 mW Indoor + outdoor 140 5700 149 5745 165 200 mW Indoor only 116 100 mW Indoor + outdoor 64 Use 48 11a 11n PWR (EIRP) 400 mW Indoor + outdoor 5825 Approvals SCALANCE W700 802.11n 94 Reference Manual, 01/2017, C79000-G8976-C392-05 Approvals for SCALANCE W770/W730 802.11n 3.4 SCALANCE W778/738 national approvals 3.4 SCALANCE W778/738 national approvals The following table lists the countries in which the SCALANCE W700 product is approved. The diamond symbol (♦) identifies all countries for which there was no approval at the time these operating instructions were written. The current status of the approvals can be found on the Internet at the following address: http://www.siemens.com/funkzulassungen Column Meaning Country Country Mode IEEE 802.11 standard and the TPC and / or DFS functionality, where required CH Channel MHz Frequency PWR (EIRP) Maximum permitted effective isotropic radiated power Use Permitted use indoors and / or outdoors Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 95 Approvals for SCALANCE W770/W730 802.11n 3.4 SCALANCE W778/738 national approvals Country Mode Andorra Belgium Bosnia and Herzegovina Bulgaria Denmark Germany Estonia Finland France Greece Great Britain Ireland Iceland Italy Croatia Latvia Liechtenstein Lithuania Luxembourg Malta Macedonia Monaco Montenegro Netherlands Norway Austria Poland Portugal Romania San Marino Sweden Switzerland Serbia ♦ Slovakia Slovenia Spain Czech Republic Turkey Hungary Vatican Cyprus 11g 11n CH MHz PWR (EIRP) Use 13 2412 2472 100 mW Indoor + outdoor 36 48 5180 5240 200 mW Indoor only TPC 52 64 5260 5320 200 mW Indoor only DFS + TPC 100 116 5500 5580 1000 mW Indoor + outdoor 132 140 5660 5700 1000 mW Indoor + outdoor 149 165 5745 5825 25 mW Indoor + outdoor 11a 11n 11a 11n 11a 11n Approvals SCALANCE W700 802.11n 96 Reference Manual, 01/2017, C79000-G8976-C392-05 Approvals for SCALANCE W770/W730 802.11n 3.4 SCALANCE W778/738 national approvals Country Mode Egypt ♦ 11g 11n CH 11a 11n TPC Australia ♦ 11g 11n New Zealand ♦ 11a 11n MHz 2412 13 2472 36 5180 DFS + TPC 5320 2412 13 2472 36 5180 11a 11n 48 5240 5260 Bahrain ♦ 11g 11n 5320 149 5745 11a 11n 5825 2412 11a 11n DFS + TPC 2472 36 5180 11a 11n 5240 52 5260 64 5320 5745 400 mW Indoor + outdoor 100 mW Indoor + outdoor 200 mW Indoor only 200 mW Indoor only 149 165 200 mW Indoor only 48 200 mW Indoor only 13 100 mW Indoor + outdoor 165 200 mW Indoor only 64 100 mW Indoor + outdoor 52 Use 64 11a 11n PWR (EIRP) 2000 mW Indoor + outdoor 5825 Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 97 Approvals for SCALANCE W770/W730 802.11n 3.4 SCALANCE W778/738 national approvals Country Mode Brazil ♦ 11g 11n CH 11a 11n MHz 2412 13 2472 36 5180 11a 11n TPC 5240 52 5260 Chile ♦ 11g 11n 11a 11n TPC 5320 100 5500 11a 11n DFS + TPC 5700 149 5745 11a 11n DFS China ♦ 11g 11n 5825 2412 13 2472 36 5180 5240 52 5260 11a 11n TPC 5320 149 5745 11a 11n DFS + TPC 5825 2412 11a 11n 2472 36 5180 5240 52 5260 100 mW Indoor only 100 mW Indoor + outdoor 200 mW Indoor only 200 mW Indoor only 64 5320 149 5745 100 mW Indoor only 48 165 100 mW Indoor only 13 100 mW Indoor only 165 4000 mW Indoor + outdoor 64 1000 mW Indoor + outdoor 48 200 mW Indoor only 165 200 mW Indoor only 140 4000 mW Indoor + outdoor 64 Use 48 11a 11n PWR (EIRP) 2000 mW Indoor + outdoor 5825 Approvals SCALANCE W700 802.11n 98 Reference Manual, 01/2017, C79000-G8976-C392-05 Approvals for SCALANCE W770/W730 802.11n 3.4 SCALANCE W778/738 national approvals Country Mode India ♦ 11g 11n CH 11a 11n TPC 11a 11n DFS + TPC 11a 11n MHz 2412 13 2472 36 5180 5240 52 5260 11g 11n 11a 11n 5320 149 5745 Japan ♦ 11g 11n 5825 2412 2472 149 5745 200 mW Indoor + outdoor 100 mW Indoor + outdoor 400 mW Indoor + outdoor 161 5805 2412 200 mW Indoor + outdoor 13 2472 11a 16 5040 5080 200 mW Indoor + outdoor 11a 11n 36 5180 200 mW Indoor only 11a 11n DFS + TPC 11a 11g 11n 5240 52 5260 TPC 200 mW Indoor only 64 5320 100 5500 200 mW Indoor + outdoor 140 5700 184 196 4920 4980 200 mW Indoor + outdoor 2412 400 mW Indoor + outdoor 11a 11n 48 Korea ♦ 200 mW Indoor only 13 200 mW Indoor only 165 100 mW Indoor + outdoor 64 Use 48 Indonesia ♦ PWR (EIRP) 13 2472 149 5745 161 400 mW Indoor + outdoor 5805 Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 99 Approvals for SCALANCE W770/W730 802.11n 3.4 SCALANCE W778/738 national approvals Country Mode Kuwait ♦ 11g 11n CH 11a 11n TPC 11a 11n DFS + TPC Mexico ♦ 11g 11n 11a 11n MHz 2412 13 2472 36 5180 5240 52 5260 100 mW Indoor + outdoor 200 mW Indoor + outdoor 200 mW Indoor + outdoor 64 5320 2412 11 2462 36 5180 500 mW Indoor + outdoor 1000 mW Indoor + outdoor 64 5320 149 5745 Use 48 South Africa ♦ PWR (EIRP) 1000 mW Indoor + outdoor 165 5825 13 2412 2472 100 mW Indoor + outdoor 36 48 5180 5240 200 mW Indoor only TPC 52 64 5260 5320 200 mW Indoor only DFS + TPC 100 116 5500 5580 1000 mW Indoor + outdoor 132 140 5660 5700 1000 mW Indoor + outdoor 11g 11n 11a 11n 11a 11n Approvals SCALANCE W700 802.11n 100 Reference Manual, 01/2017, C79000-G8976-C392-05 Approvals for SCALANCE W770/W730 802.11n 3.4 SCALANCE W778/738 national approvals Country Mode Singapore ♦ 11g 11n CH 11a 11n TPC 11a 11n DFS + TPC 11a 11n MHz 2412 13 2472 36 5180 5240 52 5260 11g 11n 11a 11n DFS + TPC 11a 11n 11g 11n Peru ♦ Thailand ♦ USA ♦ 11a 11n DFS + TPC 200 mW Indoor + outdoor 200 mW Indoor + outdoor 5320 100 116 5500 5580 1000 mW Indoor + outdoor 132 140 5660 5700 1000 mW Indoor + outdoor 149 5745 1000 mW Indoor + outdoor 165 5825 2412 100 mW Indoor + outdoor 2417 200 mW Indoor + outdoor 10 2457 11 2462 100 mW Indoor + outdoor 52 5260 400 mW Indoor + outdoor 64 5320 100 116 5500 5580 400 mW Indoor + outdoor 132 140 5660 5700 400 mW Indoor + outdoor 149 5745 400 mW Indoor + outdoor 165 5825 2412 11 2462 36 5180 11a 11n 100 mW Indoor + outdoor 64 Canada ♦ Use 48 Taiwan ♦ PWR (EIRP) 48 5240 5260 200 mW Indoor only 52 64 100 mW Indoor + outdoor 400 mW Indoor + outdoor 5320 Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 101 Approvals for SCALANCE W770/W730 802.11n 3.4 SCALANCE W778/738 national approvals Country Mode 11a 11n CH MHz PWR (EIRP) Use 100 116 5500 5580 400 mW Indoor + outdoor 132 140 5660 5700 400 mW Indoor + outdoor 149 5745 400 mW Indoor + outdoor 165 5825 Approvals SCALANCE W700 802.11n 102 Reference Manual, 01/2017, C79000-G8976-C392-05 4 Approvals for SCALANCE W760/W720 802.11n Note Issued approvals on the type plate of the device The specified approvals apply only when the corresponding mark is printed on the product. You can check which of the following approvals have been granted for your product by the markings on the type plate. Range of validity The approvals listed in this section apply to the following products: Article number Article number of the US version Article number of the Israel version 6GK5761-1FC000AA0 6GK5761-1FC000AB0 SCALANCE W722-1 RJ45 (iFeatures) 6GK5722-1FC000AA0 6GK5722-1FC000AB0 6GK5722-1FC00-0AC0 SCALANCE W721-1 RJ45 6GK5721-1FC000AA0 6GK5721-1FC000AB0 Access point SCALANCE W761-1 RJ45 Ethernet client modules Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 103 Approvals for SCALANCE W760/W720 802.11n 4.1 EC declaration of conformity 4.1 EC declaration of conformity The EC Declaration of Conformity is available for all responsible authorities at: Siemens Aktiengesellschaft Process Industries and Drives Division, Process Automation DE-76181 Karlsruhe Germany You will find the current EC declaration of conformity for these products on the Internet pages of Siemens Industry Online Support (hhttps://support.industry.siemens.com/cs/ww/en/ps/15853/cert). The SIMATIC NET products described in these Operating Instructions meet the requirements of the following EC directives: ● 94/9/EC Directive of the European Parliament and the Council of 23 March 1994 on the approximation of the laws of the Member States concerning equipment and protective systems intended for use in potentially explosive atmospheres (until 19.04.2016). ● 2014/34/EU Directive 2014/34/EU of the European Parliament and of the Council of 26 February 2014 on the harmonization of the laws of the Member States relating to equipment and protective systems intended for use in potentially explosive atmospheres official journal of the EU L96, 29/03/2014, pages. 309–356 (as of 20.04.2016) ● 1999/5/EC Directive of the European Parliament and of the Council of 1999 March 1999 on Radio Equipment and Telecommunications Terminal Equipment and the mutual recognition of their conformity (until 12.06.2016). ● 2014/53/EU Directive of the European Parliament and of the Council of April 16, 2014 on the harmonization of the laws of the member states relating to placing radio equipment on the market.; official journal of the EU L153, 22/05/2014, pages. 62–106 (as of 13.06.2016) ● 2011/65/EU (RoHS) RoHS directive of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment. ● 1999/519/EC Council recommendation on the limitation of exposure of the general public to electromagnetic fields (0 Hz to 300 GHz) Approvals SCALANCE W700 802.11n 104 Reference Manual, 01/2017, C79000-G8976-C392-05 Approvals for SCALANCE W760/W720 802.11n 4.1 EC declaration of conformity 4.1.1 ATEX ATEX directive (correct usage in potentially explosive atmospheres) The SIMATIC NET product meets the requirements of the EC directive:94/9/EC (until 19.04.2016) and 2014/34/EU (as of 20.04.2016) "Equipment and Protective Devices for Use in Potentially Explosive Atmospheres" according to the standards listed in the section AUTOHOTSPOT: Applied standard: EN 60079-0 + A11 Hazardous areas - Part 0: Equipment - General requirements EN 60079-15 Explosive atmospheres - Part 15: Equipment protection by type of protection "n" 4.1.2 RoHS RoHS directive (restriction of the use of certain hazardous substances) The SIMATIC NET products described in these operating instructions meet the requirements of the EC directive 2011/65/EC for the restriction of the use of certain hazardous substances in electrical and electronic equipment: Applied standard: EN 50581 Technical documentation for the assessment electrical and electronic products with respect to restriction of hazardous substances 4.1.3 R&TTE / RED 4.1.3.1 Protection of health and safety Article 3 (1) a) protection of health and safety EN 60950-1+A1+A2+A11+A12 Information technology equipment - Safety - Part 1: General requirements EN 62311 Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz – 300 GHz) Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 105 Approvals for SCALANCE W760/W720 802.11n 4.1 EC declaration of conformity 4.1.3.2 EMC Art. 3 (1) b - EMC EN 50121-3-2+AC Railway applications - Electromagnetic compatibility - part 3-2: Railway Vehicles Devices EN 50121-4+AC Railway applications - Electromagnetic compatibility - part 4: Interference emissions and immunity of signal telecommunications equipment ETSI EN 301 489-1 Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic compatibility for radio equipment and services - Part 1 : Common technical requirements ETSI EN 301 489-17 10 11 12 13 4.1.3.3 Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic compatibility for radio equipment and services - Part 17 : EN 61000-6-1 Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments EN 61000-6-2+AC Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments EN 61000-6-3+A1+AC Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments EN 61000-6-4+A1 Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments Efficient use of the radio spectrum Art. 3 (2) Efficient use of the radio spectrum 14 ETSI EN 301 328 Electromagnetic compatibility and radio spectrum matters (ERM) - wideband transmission systems - data transmission equipment operating in the 2.4 GHz ISM band and using wideband modulation techniques. Harmonized EN containing the essential requirements according to Article 3.2 of the R&TTE directive. 15 ETSI EN 301 893 Broadband Radio Access Networks (BRAN) - 5 GHz high performance RLAN Harmonized EN covering essential requirements of article 3.2 of the R&TTE Directive Approvals SCALANCE W700 802.11n 106 Reference Manual, 01/2017, C79000-G8976-C392-05 Approvals for SCALANCE W760/W720 802.11n 4.1 EC declaration of conformity 4.1.4 Products CE conformity The standards that apply to the product are described in RoHS (Page 105), ATEX (Page 105) and R&TTE / RED (Page 105). Product name Standards W761-1 RJ45 W722-1 RJ45 W721-1 RJ45 1, 2 3, 4, 5, 8, 9, 10, 11, 12, 13, 14, 15 W774-1 RJ45 W734-1 RJ45 W774-1 M12 EEC 1, 2 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15 Certification ID The following table shows the product names and the corresponding certification ID: Type Certification ID Order number Order number US variant W761-1 RJ-45 ELN-W1-RJ-E1 6GK5761-1FC00-0AA0 6GK5761-1FC00-0AB0 W722-1 RJ-45 ELN-W1-RJ-E1 6GK5722-1FC00-0AA0 6GK5722-1FC00-0AB0 W721-1 RJ-45 ELN-W1-RJ-E1 6GK5721-1FC00-0AA0 6GK5721-1FC00-0AB0 Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 107 Approvals for SCALANCE W760/W720 802.11n 4.2 General approvals 4.2 General approvals ATEX (explosion protection directive) WARNING When using SIMATIC NET products in hazardous area zone 2, make absolutely sure that the associated conditions in the following document are adhered to: "SIMATIC NET Product Information Use of subasseblies/modules in a Zone 2 Hazardous Area". You will find this document on the data medium that ships with some devices. on the Internet pages of Siemens Industry Online Support (http://support.automation.siemens.com/ww). Enter the document identification number C234 as the search term. The SIMATIC NET products meet the requirements of the EC directive 94/9/EC "Equipment and Protective Devices for Use in Potentially Explosive Atmospheres”. and as of 20.04.2016 the EC directive 2014/34/EU. ATEX classification: II 3 G Ex nA IIC T4 Gc KEMA 07ATEX0145 X The products meet the requirements of the following standards: ● EN 60079-15 (electrical apparatus for potentially explosive atmospheres; Type of protection "n") ● EN 60079-0 (Explosive atmospheres - Part 0: Equipment - General requirements) You will find the current versions of the standards in the currently valid ATEX certificates. IECEx The SIMATIC NET products meet the requirements of explosion protection according to IECEx. IECEx classification: Ex nA IIC T4 Gc DEK 14.0025X The products meet the requirements of the following standards: ● IEC 60079-15 (Explosive atmospheres - Part 15: Equipment protection by type of protection "n") ● IEC 60079-0 (Explosive atmospheres - Part 0: Equipment - General requirements) You will find the current versions of the standards in the currently valid IECEx certificates. Approvals SCALANCE W700 802.11n 108 Reference Manual, 01/2017, C79000-G8976-C392-05 Approvals for SCALANCE W760/W720 802.11n 4.2 General approvals FM The product meets the requirements of the standards: ● Factory Mutual Approval Standard Class Number 3611 ● FM Hazardous (Classified) Location Electrical Equipment: Non Incendive / Class I / Division 2 / Groups A,B,C,D / T4 and Non Incendive / Class I / Zone 2 / Group IIC / T4 cULus Approval Hazardous Location cULus Listed I. T. E. FOR HAZ. LOC. Underwriters Laboratories Inc. complying with ● UL 60950-1 (Information Technology Equipment) ● ANSI/ISA 12.12.01-2007 ● CSA C22.2 No. 213-M1987 Approved for use in Cl. 1, Div. 2, GP A, B, C, D T4 Cl. 1, Zone 2, GP IIC T4 Report no. E240480 Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 109 Approvals for SCALANCE W760/W720 802.11n 4.2 General approvals FCC approval This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Notice Changes or modifications made to this equipment not expressly approved by SIEMENS may void the FCC authorization to operate this equipment. IEEE 802.11b or g operation of this product in the USA is firmware-limited to channels 1 through 11. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ● Reorient or relocate the receiving antenna. ● Increase the separation between the equipment and receiver. ● Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ● Consult the dealer or an experienced radio/TV technician for help. Notice This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Professional Installation Notice: To comply with FCC part 15 rules in the United States, the system must be professionally installed to ensure compliance with the Part 15 certification. It is the responsibility of the operator and professional installer to ensure that only certified systems are deployed in the United States. The use of the system in any other combination (such as co-located antennas transmitting the same information) is expressly forbidden. Approvals SCALANCE W700 802.11n 110 Reference Manual, 01/2017, C79000-G8976-C392-05 Approvals for SCALANCE W760/W720 802.11n 4.2 General approvals Notice For use of DFS channels ● Use of the RCoax Cable Antenna 6XV1875-2D is not permitted in channels which require dynamic frequency selection (DFS). ● Any installation of either a master or a client device within 35 km of a TDWR (Terminal Doppler Weather Radar) location shall be separated by at least 30 MHz (center-to-center) from the TDWR operating frequency. These devices shall be registered in the industry sponsored WISPA database, http://udia.spectrumbridge.com/udia/home.aspx (http://udia.spectrumbridge.com/udia/home.aspx) When you open this link, you get the following choices: – "Search" opens a window with TDWR locations and frequencies. – "User Signup" allows you to register as user of the database. – After registering you can Logon and register your WLAN location. Please fill in all required information. For more information with respect to WISPA database and TWDR locations please consult FCC publication KDB 443999 D01. CSA Information Technology Equipment CSA Certification Mark Canadian Standard Association CSA C22.2 No. 60950-1-03 RSS-247 of Industry Canada This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. This radio transmitter (IC: 267AA-ELN1V1 for W760/W720 802.11n and IC: 267AA-MSN1V1 for W774/W734 802.11n) has been approved by Industry Canada to operate with the antenna types listed in section 5.6 with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that permitted for successful communication. Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 111 Approvals for SCALANCE W760/W720 802.11n 4.2 General approvals That the device for the band 5150-5250 MHz is only for indoor usage to reduce potential for harmful interference to co-channel mobile satellite systems. Users should also be cautioned to take note that high power radars are allocated as primary users (meaning they have priority) of 5250-5350 MHz and 5650-5850 MHz and these radars could cause interference and/or damage to LE-LAN devices. This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. RCM The product meets the requirements of the AS/NZS 2064 standard (Class A). Approvals for Argentina Devices of the SCALANCE W760/W720 series are approved in Argentina under the following certification number: Certification ID Certification number ELN-W1-RJ-E1 CNC: C-13172 Devices of the SCALANCE W770/W730 series are approved in Argentina under the following certification numbers: Certification ID Certification number MSN-W1-RJ-E2 CNC: C-13164 MSN-W1-M12-E2 CNC: C-13163 Approval for Brazil Devices of the SCALANCE W760/W720 series are approved in Brazil under the following certification numbers: Este equipamento opera em caráter secundário, isto, ist é, não tem direito à proteção contra interferência prejudicial, mesmo de estações do mesmo tipo e não pode causar interferência a sistemas operando em caráter primário. Approvals SCALANCE W700 802.11n 112 Reference Manual, 01/2017, C79000-G8976-C392-05 Approvals for SCALANCE W760/W720 802.11n 4.2 General approvals Devices of the SCALANCE W770/W730 series are approved in Brazil under the following certification numbers: Este equipamento opera em caráter secundário, isto, ist é, não tem direito à proteção contra interferência prejudicial, mesmo de estações do mesmo tipo e não pode causar interferência a sistemas operando em caráter primário. KCC Statement (Republic of Korea) 사용자안내문(제5조제1항제1호관련) 기종별 A 급 기기급 기기 (업무용 방송통신기기) 사용자안내문 이 기기는 업무용(A 급)으로 전자파적합등록을 한(A 급)으로 전자파적합등록을 한 기기이오니 판매자 또는 사용자는 이 점을 주의하시기 바라며, 가정외의 지역에서 사용하는 것을 목적으로 합니다. "당해 무선설비는 전파혼신 가능성이 있으므로 인명안전과 관련된 서비스는 할 수 없음" Marking for the customs union EAC (Eurasian Conformity) Customs union of Russia, Belarus and Kazakhstan Declaration of the conformity according to the technical regulations of the customs union (TR CU) Railway approval for the SCALANCE W774-1 M12 EEC The SCALANCE W774-1 M12 EEC device meets the requirements of the railway standard EN 50155:2007 "Railway Applications - Electronic equipment used on rolling stock". Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 113 Approvals for SCALANCE W760/W720 802.11n 4.3 National approvals 4.3 National approvals The following table lists the countries in which the SCALANCE W700 product is approved. The diamond symbol (♦) identifies all countries for which there was no approval at the time these operating instructions were written. The current status of the approvals can be found on the Internet at the following address: http://www.siemens.com/funkzulassungen Column Meaning Country Country Mode IEEE 802.11 standard and the TPC and / or DFS functionality, where required CH Channel MHz Frequency PWR (EIRP) Maximum permitted effective isotropic radiated power Use Permitted use indoors and / or outdoors Approvals SCALANCE W700 802.11n 114 Reference Manual, 01/2017, C79000-G8976-C392-05 Approvals for SCALANCE W760/W720 802.11n 4.3 National approvals Country Mode Andorra Belgium Bosnia and Herzegovina Bulgaria Denmark Germany Estonia Finland France Greece Great Britain Ireland Iceland Italy Croatia Latvia Liechtenstein Lithuania Luxembourg Malta Macedonia Monaco Montenegro Netherlands Norway Austria Poland Portugal Romania San Marino Sweden Switzerland Serbia Slovakia Slovenia Spain Czech Republic Turkey Hungary Vatican Cyprus 11g 11n CH MHz PWR (EIRP) Use 13 2412 2472 100 mW Indoor + outdoor 36 48 5180 5240 200 mW Indoor only TPC 52 64 5260 5320 200 mW Indoor only DFS + TPC 100 116 5500 5580 1000 mW Indoor + outdoor 132 140 5660 5700 1000 mW Indoor + outdoor 11a 11n 11a 11n Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 115 Approvals for SCALANCE W760/W720 802.11n 4.3 National approvals Country Mode Egypt 11g 11n CH 11a 11n TPC Angola 11g 11n 11a 11n TPC 11a 11n DFS + TPC MHz 2412 13 2472 36 5180 5320 2412 13 2472 36 5180 5240 52 5260 200 mW Indoor only 100 mW Indoor + outdoor 200 mW Indoor only 200 mW Indoor only 64 5320 100 5500 1000 mW Indoor + outdoor 116 5580 132 5660 100 mW Indoor + outdoor 48 Use 64 Argentina PWR (EIRP) 1000 mW Indoor + outdoor 140 5700 11g 11n 13 2412 2472 1000 mW Indoor + outdoor 11a 11n 36 48 5180 5240 50 mW Indoor + outdoor 11a 11n 52 64 5260 5320 250 mW Indoor + outdoor 100 120 5500 5600 250 mW Indoor + outdoor 132 140 5660 5700 250 mW Indoor + outdoor 149 165 5745 5825 1000 mW Indoor + outdoor TPC 11a 11n Approvals SCALANCE W700 802.11n 116 Reference Manual, 01/2017, C79000-G8976-C392-05 Approvals for SCALANCE W760/W720 802.11n 4.3 National approvals Country Mode CH Australia 11g 11n 13 2412 2472 100 mW Indoor + outdoor 11a 11n 36 48 5180 5240 200 mW Indoor only 11a 11n 52 64 5260 5320 200 mW Indoor only 11a 11n 149 165 5745 5825 400 mW Indoor + outdoor 11g 11n 13 2412 2472 100 mW Indoor + outdoor 11a 11n 36 48 5180 5240 200 mW Indoor only 11a 11n 52 64 5260 5320 200 mW Indoor only 11a 11n 149 165 5745 5825 2000 mW Indoor + outdoor 11g 11n 2412 100 mW Indoor + outdoor New Zealand DFS + TPC Bahrain DFS + TPC Belarus 11a 11n TCP 11a 11n TCP + DFS MHz 13 2472 36 5180 5240 52 5260 Use 100 mW Indoor + outdoor 48 100 mW Indoor + outdoor 64 5320 132 5660 Brazil PWR (EIRP) 100 mW Indoor + outdoor 140 5700 11g 11n 13 2412 2472 11a 11n 36 48 5180 5240 200 mW Indoor only 11a 11n 52 64 5260 5320 200 mW Indoor only TPC 4000 mW Indoor + outdoor Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 117 Approvals for SCALANCE W760/W720 802.11n 4.3 National approvals Country Chile Mode CH PWR (EIRP) Use 100 140 5500 5700 1000 mW Indoor + outdoor 11a 11n 149 165 5745 5825 4000 mW Indoor + outdoor 11g 11n 13 2412 2472 100 mW Indoor only 11a 11n 36 5180 100 mW Indoor only TPC 11a 11n DFS+TPC 11a 11n DFS China MHz 11g 11n 11a 11n TPC 11a 11n DFS+TPC 11a 11n 48 5240 52 5260 100 mW Indoor only 64 5320 149 165 5745 5825 100 mW Indoor only 13 2412 100 mW Indoor + outdoor 2472 36 5180 48 5240 52 5260 200 mW Indoor only 200 mW Indoor only 64 5320 149 165 5745 5825 2000 mW Indoor + outdoor Approvals SCALANCE W700 802.11n 118 Reference Manual, 01/2017, C79000-G8976-C392-05 Approvals for SCALANCE W760/W720 802.11n 4.3 National approvals Country Mode Ivory Coast 11g 11n CH 11a 11n TPC 11a 11n DFS + TPC MHz 2412 13 2472 36 5180 5240 52 5260 100 mW Indoor + outdoor 200 mW Indoor only 200 mW Indoor only 64 5320 100 5500 1000 mW Indoor + outdoor 116 5580 132 5660 Use 48 Guatemala PWR (EIRP) 1000 mW Indoor + outdoor 140 5700 11g 11n 11 2412 2462 100 mW Indoor + outdoor 11a 11n 36 5180 200 mW Indoor only 11a 11n DFS + TPC 48 5240 52 5260 5320 100 5500 400 mW Indoor + outdoor 116 5580 132 5660 400 mW Indoor + outdoor 64 11a 11n 400 mW Indoor + outdoor 140 5700 149 165 5745 5825 400 mW Indoor + outdoor Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 119 Approvals for SCALANCE W760/W720 802.11n 4.3 National approvals Country Mode Hong Kong 11g 11n CH 11a 11n TPC 11a 11n DFS + TPC MHz 2412 13 2472 36 5180 5240 52 5260 11g 11n 11a 11n TPC 5320 100 5500 11a 11n DFS + TPC 5580 132 5660 11a 11n 5700 2412 13 2472 36 5180 Indonesia ♦ Israel 1000 mW Indoor + outdoor 1000 mW Indoor + outdoor 100 mW Indoor + outdoor 200 mW Indoor only 48 5240 52 5260 200 mW Indoor only 64 5320 149 5745 200 mW Indoor only 140 200 mW Indoor only 116 100 mW Indoor + outdoor 64 Use 48 India PWR (EIRP) 200 mW Indoor + outdoor 165 5825 11g 11n 13 2412 2472 100 mW Indoor + outdoor 11a 11n 149 161 5745 5805 400 mW Indoor + outdoor 11g 11n 13 2412 2472 100 mW Indoor + outdoor 36 5180 200 mW Indoor only 11a 11n TPC 11a 11n DFS + TPC 48 5240 52 64 5260 5320 200 mW Indoor only Approvals SCALANCE W700 802.11n 120 Reference Manual, 01/2017, C79000-G8976-C392-05 Approvals for SCALANCE W760/W720 802.11n 4.3 National approvals Country Mode CH Japan 11g 11n 13 2412 2472 100 mW Indoor + outdoor 11a 16 5040 5080 200 mW Indoor + outdoor 11a 11n 36 48 5180 5240 200 mW Indoor only 11a 11n 52 64 5260 5320 200 mW Indoor only 100 140 5500 5700 200 mW Indoor + outdoor 184 196 4920 4980 200 mW Indoor + outdoor 2412 100 mW Indoor + outdoor DFS + TPC 11a Kazakhstan 11g 11n MHz 11a 11n TPC 11a 11n DFS + TPC 2472 36 5180 Korea 11g 11n 100 mW Indoor + outdoor 48 5240 52 5260 Use 13 100 mW Indoor + outdoor 64 5320 132 5660 Qatar PWR (EIRP) 100 mW Indoor + outdoor 140 5700 2412 100 mW Indoor only 13 2472 11a 11n 149 165 5745 5825 100 mW Indoor only 11g 11n 13 2412 2472 400 mW Indoor + outdoor 149 161 5745 5805 400 mW Indoor + outdoor 11a 11n TPC Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 121 Approvals for SCALANCE W760/W720 802.11n 4.3 National approvals Country Mode Kuwait 11g 11n CH 100 mW Indoor + outdoor 36 48 5180 5240 100 mW Indoor + outdoor TPC 52 64 5260 5320 100 mW Indoor + outdoor DFS + TPC 11g 11n 13 2412 2472 100 mW Indoor + outdoor 11a 11n 149 161 5745 5805 100 mW Indoor + outdoor 11g 11n 13 2412 2472 100 mW Indoor + outdoor 11a 11n 5180 5240 200 mW Indoor only TPC 36 48 52 64 5260 5320 200 mW Indoor only DFS + TPC 100 5500 11a 11n 11a 11n 5580 132 5660 11g 11n 5700 149 5745 11a 11n DFS 5825 2412 11a 11n 2472 56 5280 5320 149 5745 165 200 mW Indoor only 64 200 mW Indoor + outdoor 13 400 mW Indoor + outdoor 165 1000 mW Indoor + outdoor 140 1000 mW Indoor + outdoor 116 Malaysia Use 2412 2472 11a 11n Madagascar PWR (EIRP) 13 11a 11n Macau MHz 1000 mW Indoor + outdoor 5825 Approvals SCALANCE W700 802.11n 122 Reference Manual, 01/2017, C79000-G8976-C392-05 Approvals for SCALANCE W760/W720 802.11n 4.3 National approvals Country Mode Mexico 11g 11n 11 2412 2462 11a 11n 36 64 5180 5320 1000 mW Indoor only 149 165 5745 5825 1000 mW Indoor + outdoor 2412 100 mW Indoor + outdoor Pakistan CH 11g 11n 11a 11n MHz 13 2472 149 5745 Russia Use 100 mW Indoor + outdoor 100 mW Indoor + outdoor 165 5825 11g 11n 13 2412 2472 100 mW Indoor + outdoor 11a 11n 5180 5240 100 mW Indoor + outdoor TPC 36 48 5260 5320 100 mW Indoor + outdoor DFS + TPC 52 64 132 140 5660 5700 100 mW Indoor + outdoor 13 2412 2472 100 mW Indoor + outdoor 36 48 5180 5240 200 mW Indoor only TPC 52 64 5260 5320 200 mW Indoor only DFS + TPC 100 112 5500 5560 200 mW Indoor + outdoor 116 140 5580 5700 200 mW Indoor + outdoor 11a 11n Saudi Arabia PWR (EIRP) 11g 11n 11a 11n 11a 11n Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 123 Approvals for SCALANCE W760/W720 802.11n 4.3 National approvals Country Mode CH Singapore 11b 11g 11n Philippines 11a 11n TPC 11a 11n DFS + TPC 11a 11n MHz 2412 13 2472 36 5180 5240 52 5260 Use 100 mW Indoor + outdoor 200 mW Indoor + outdoor 48 200 mW Indoor + outdoor 64 5320 100 116 5500 5580 1000 mW Indoor + outdoor 132 140 5660 5700 1000 mW Indoor + outdoor 149 5745 1000 mW Indoor + outdoor South Africa PWR (EIRP) 165 5825 13 2412 2472 100 mW Indoor + outdoor 36 48 5180 5240 200 mW Indoor only TPC 52 64 5260 5320 200 mW Indoor only DFS+TPC 100 116 5500 5580 1000 mW Indoor + outdoor 132 140 5660 5700 1000 mW Indoor + outdoor 11g 11n 11a 11n 11a 11n Approvals SCALANCE W700 802.11n 124 Reference Manual, 01/2017, C79000-G8976-C392-05 Approvals for SCALANCE W760/W720 802.11n 4.3 National approvals Country Mode Taiwan ♦ 11g 11n CH 2412 100 mW Indoor + outdoor 200 mW Indoor + outdoor 10 2417 2457 11 2462 100 mW Indoor + outdoor 52 64 5260 5320 400 mW Indoor only 100 116 5500 5580 400 mW Indoor + outdoor 132 140 5660 5700 400 mW Indoor + outdoor 11a 11n 149 165 5745 5825 400 mW Indoor + outdoor 11g 11n 13 2412 2472 1000 mW Indoor + outdoor 11a 11n 36 48 5180 5240 200 mW Indoor only 52 64 5260 5320 1000 mW Indoor only 11a 11n 149 165 5745 5825 4000 mW Indoor + outdoor 11g 11n 13 2412 2472 100 mW Indoor + outdoor 36 48 5180 5240 200 mW Indoor only TPC 52 64 5260 5320 200 mW Indoor only DFS+TPC 100 116 5500 5580 1000 mW Indoor only 132 140 5660 5700 1000 mW Indoor only 11 2412 2462 11a 11n DFS 11a 11n 11a 11n Bahamas Use DFS+TPC United Arab Emirates PWR (EIRP) 11a 11n Venezuela MHz 11g 11n Canada 100 mW Indoor + outdoor Approvals SCALANCE W700 802.11n Reference Manual, 01/2017, C79000-G8976-C392-05 125 Approvals for SCALANCE W760/W720 802.11n 4.3 National approvals Country Mode Colombia 11a 11n CH 36 Peru Puerto Rico Thailand USA MHz 11a 11n DFS + TPC Uruguay 11a 11n 5180 48 5240 5260 Use 200 mW Indoor only 52 400 mW Indoor + outdoor 64 5320 100 116 5500 5580 400 mW Indoor + outdoor 132 140 5660 5700 400 mW Indoor + outdoor 149 5745 400 mW Indoor + outdoor Vietnam PWR (EIRP) 165 5825 13 2412 2472 100 mW Indoor + outdoor 36 48 5180 5240 200 mW Indoor only TPC 52 64 5260 5320 200 mW Indoor only DFS+TPC 100 116 5500 5580 1000 mW Indoor + outdoor 132 140 5660 5700 1000 mW Indoor + outdoor 149 165 5745 5825 400 mW Indoor + outdoor 11g 11n 11a 11n 11a 11n 11a 11n Approvals SCALANCE W700 802.11n 126 Reference Manual, 01/2017, C79000-G8976-C392-05
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Create Date : 2017:09:06 16:36:00+02:00 Page Count : 126 XMP Toolkit : XMP Core 4.1.1 Part : 1 Conformance : B Producer : PDF-XChange Printer 2012 (5.5 build 315) [Windows 7 Enterprise x64 (Build 7601: Service Pack 1)] Modify Date : 2017:09:06 16:36+02:00 Format : application/pdfEXIF Metadata provided by EXIF.tools