Siemens RF310R02 RFID Reader 13.56 MHz User Manual SIMATIC RF300
Siemens AG RFID Reader 13.56 MHz SIMATIC RF300
Siemens >
Contents
User Manual part 3
Appendix A.1 Certificates and approvals All the latest RFID radio approvals are available on the Internet (http://www.siemens.com/rfid-approvals). Labeling Description Conformity acc. to the RED EU directive Notes on CE marking The following applies to the system described in this documentation: The CE marking on a device indicates the corresponding approval. DIN ISO 9001 certificate The quality assurance system for the entire product process (development, production, and marketing) at Siemens fulfills the requirements of ISO 9001 (corresponds to EN29001: 1987). This has been certified by DQS (the German society for the certification of quality management systems). EQ-Net certificate no.: 1323-01 Country-specific approvals Safety If the device has one of the following markings the corresponding approval has been obtained: Labeling Description Underwriters Laboratories (UL) to UL 60950 Standard (I.T.E), UL508 or UL61010-1/UL61010-2-201 (IND.CONT.EQ) Underwriters Laboratories (UL) according to Canadian standard C22.2 No. 60950 (I.T.E), C22.2 No. 142 or C22.2 NO. 61010-1-12 (IND.CONT.EQ) Underwriters Laboratories (UL) according to Standard UL 60950, Report E11 5352 and Canadian standard C22.2 No. 60950 (I.T.E), UL508 or UL61010-1/UL61010-2-201 (IND.CONT.EQ) and C22.2 No. 142 or C22.2 NO. 61010-1-12 (IND.CONT.EQ) SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 405 Appendix A.1 Certificates and approvals Labeling Description UL recognition mark Canadian Standard Association (CSA) acc. to standard C22.2. No. 60950 (LR 81690), C22.2 No. 142 or C22.2 NO. 61010-1-12 (LR 63533) Canadian Standard Association (CSA) acc. to American Standard UL 60950 (LR 81690), UL508 or UL61010-1/UL61010-2-201 (LR 63533) This product meets the requirements of the AS/NZS 3548 Norm. USA (FCC) This device complies with Part 15 of the FCC Rules. FCC ID: NXW-RF... Canada (IC) Canada (IC) This device complies with Industry Canada licence-exempt RSS standard(s). IC: 267X-RF... Russia, Belarus and Kazakhstan Brazil (ANATEL) ANATEL-ID: XXXX-YY-ZZZZ Mexico (COFETEL) Mexico (COFETEL) South Africa (ICASA) China (CMIIT) China (CMIIT) CMIIT ID: XXXXYYZZZZ South Korea (KCC) Japan (VCCI) SIMATIC RF300 406 System Manual, 07/2016, C79000-G8976-C345-0x Appendix A.2 Accessories A.2 Accessories A.2.1 Transponder holders Table A- 1 Overview of the transponder holders and spacers Product photo Insertable transponders • MDS D100 • MDS D200 • MDS D400 • MDS E600 • MDS E611 • RF360T 6GT2190-0AA00 6GT2190-0AB00 • MDS D100 • MDS D200 • MDS D400 • MDS E600 • MDS E611 • RF360T • MDS D100 • MDS D200 • MDS D400 • MDS E600 • MDS E611 Characteristics • Spacer for mounting on metal, in conjunction with the fixing pocket 6GT2190-0AB00 • Distance from transponder to metal: 25 mm • Mounting: 4 x M4 screws • Material: PA6 • Weight: 31 g • Dimensions (L x W x H): 110 x 62 x 24 mm • Fixing pocket in conjunction with spacer 6GT21900AA00 • Mounting: – Locks into spacer – 2 x screws/nails – Tacked • Material: PA6 • Weight: 12 g • Dimensions (L x W x H): 121 x 57 x 5 mm • Fixing pocket not suitable for mounting directly on metal • Mounting: 2 x M4 countersunk screws • Material: PA6 • Weight: 21 g • Dimensions (L x W x H): 110 x 65 x 5 mm 6GT2390-0AA00 SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 407 Appendix A.2 Accessories Product photo Insertable transponders Characteristics • MDS D139 • Spacer for mounting on metal • MDS D339 • Distance from transponder to metal: 30 mm • Mounting: 1 x M5 stainless steel screw • Tightening torque: 1.5 Nm • Material: PPS • Weight: 50 g • Dimensions (Ø x H): 85 x 30 mm 6GT2690-0AA00 • MDS D139 • Quick change holder for mounting on metal • MDS D339 • Distance from transponder to metal: 30 mm • Mounting: Screw-in 6GT2690-0AH00 • Material: Stainless steel VA • Weight: 80 g • Dimensions (Ø x H): 22 x 60 mm • MDS D139 • Quick change holder for mounting on metal • MDS D339 • Distance from transponder to metal: 30 mm • Mounting: Screw-in • Material: Stainless steel VA • Weight: 60 g • Dimensions (Ø x H): 22 x 47 mm 6GT2690-0AH10 • MDS D124 • Spacer for mounting on metal • MDS D324 • Distance from transponder to metal: 15 mm • MDS D424 • Mounting: 1 x M4 countersunk screw • MDS D524 • Tightening torque: ≤ 1 Nm • Material: PPS • Weight: Approx. 4 g • Remounting cycles: min. 10 • Dimensions (Ø x H): 36 x 22 mm 6GT2690-0AK00 SIMATIC RF300 408 System Manual, 07/2016, C79000-G8976-C345-0x Appendix A.2 Accessories Product photo Insertable transponders Characteristics • MDS D126 • Spacer for mounting on metal • MDS D426 • Distance from transponder to metal: 25 mm • MDS D526 • Mounting: 1 x M4 countersunk screw • MDS E624 • Tightening torque: ≤ 1 Nm • Material: PA6 • Weight: Approx. 12 g • Remounting cycles: min. 10 • Dimensions (Ø x H): 59 x 30 mm 6GT2690-0AL00 • MDS D160 • Spacer for mounting on metal • MDS D460 • Distance from transponder to metal: 10 mm • Mounting: 1 x M3 countersunk screw • Material: PA6 • Weight: 2 g • Dimensions (Ø x H): 20 x 14 mm 6GT2690-0AG00 • MDS D423 • Fixing hood • RF330T • Mounting: 2 x M4 or 2 x M5 screws with max. head diameter of 9.5 mm • Tightening torque ≤ 0.8 Nm (M4 only with flat washer) • Material: PPS • Weight: 3 g • Dimensions (L x W x H): 49.4 x 20 x 9.8 mm 6GT2690-0EA00 SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 409 Appendix A.2 Accessories Dimensional drawings Figure A-1 Dimension drawing of spacer 6GT2190-0AA00 with fixing pocket 6GT2190-0AB00 Figure A-2 Dimension drawing of fixing pocket 6GT2390-0AA00 SIMATIC RF300 410 System Manual, 07/2016, C79000-G8976-C345-0x Appendix A.2 Accessories Figure A-3 Dimension drawing of spacer 6GT2690-0AA00 Figure A-4 Dimension drawing of quick change holder 6GT2690-0AH00 SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 411 Appendix A.2 Accessories Figure A-5 Dimension drawing of quick change holder 6GT2690-0AH10 Figure A-6 Dimension drawing of spacer 6GT2690-0AK00 Figure A-7 Dimension drawing of spacer 6GT2690-0AL00 SIMATIC RF300 412 System Manual, 07/2016, C79000-G8976-C345-0x Appendix A.2 Accessories Figure A-8 Dimension drawing of spacer 6GT2690-0AG00 Figure A-9 Dimension drawing of fixing hood 6GT2690-0EA00 SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 413 Appendix A.2 Accessories A.2.2 MOBY I migration The RF300 readers of the new generation provide the option of simple migration of existing MOBY I systems to SIMATIC RF300. The so-called MOBY I emulation processes frames of the MOBY I protocol on its serial interface and communicates with the established RF300 transponders. If the RF300 reader is connected to a communications module with MOBY I capability, the reader automatically recognizes the serial protocol and sets the MOBY I protocol. As a communications module with MOBY I capability, all the communications modules sold for MOBY I count regardless of the mode in which the MOBY I communications modules are operated. This property allows even projects with the ECC mode turned on or with file handlers to be migrated. Communication modules with MOBY I capability: RF180C, RFID 181EIP, RF170C, ASM 456, ASM 475, ASM 470, ASM450, ASM 451, ASM 452, ASM 472, ASM 473, ASM 424, ASM 454, ASM 400, CM 422, CM 423, ASM 410, ASM 420, ASM 421, ASM 440, ES030 With the aid of the adapter cable (0.3 m; article number 6GT2091-4VE30) you can migrate existing MOBY I projects without needing to re-cable the connected RFID devices. The transfer is as usual with MOBY I with a transmission speed of 19.2 kBd. The transmission speed in the application is identical (or slightly slower) than with the original MOBY I hardware. NOTICE Changed field geometry When replacing MOBY I components with RF300 components note that the field geometry changes. SIMATIC RF300 414 System Manual, 07/2016, C79000-G8976-C345-0x Appendix A.2 Accessories Design of the Y adapter With the aid of the Y adapter (article number 6GT2090-4VE00) a slow migration of a MOBY I application to RF300 is possible. The Y adapter is mounted in the vicinity of a MOBY I SLG. It forwards signals of a communications module both to the MOBY I SLG and to the RF300 readers to be newly installed. The transponder commands are handled either with a MOBY I transponder or with an RF300 transponder. To do this, no change to the MOBY I application is necessary. ① ② Power Optional 24 VDC supply voltage, M12 plug, 4-pin Connector for the communications module; SLG plug, 6-pin acc. to EN 175201-804 ③ ④ ASM TxD RF300 Connector for RF 300 reader; M12 socket, 8-pin MOBY l Connector for the MOBY I reader; SLG socket (angled), plug, 6-pin acc. to EN 175201-804 Figure A-10 = 0.5 m Connection graphic of the MOBY Y adapter for MOBY I Command set The command set of the MOBY I readers is supported by the RF300 readers. You will find a list of the commands and a description of the commands in the manuals "FB 45" and "FC 56". These manuals can be found in the archive of the DVD "Ident Systems Software & Documentation" (6GT2080-2AA20). SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 415 Appendix A.2 Accessories A.2.3 DVD "Ident Systems Software & Documentation" The DVD contains: ● FB/FC for SIMATIC, 3964R ● Drivers for DOS/Windows XP/Win 7 ● C libraries ● PC demonstration program ● RFID documentation in PDF format, especially RFID system manuals, programming instructions and operating instructions Table A- 2 Ordering data DVD Article number DVD "Ident Systems Software & Documentation" 6GT2080-2AA20 Note Notes on "Ident Systems Software" and licensing When purchasing a communication module or an interface module, no software or documentation is supplied. The "Ident Systems Software & Documentation" DVD contains all available FBs/FCs for the SIMATIC, C libraries, demo programs, etc. and needs to be ordered separately. In addition, the DVD contains the complete Ident documentation (German and English) in PDF format. The purchase of a communications module or an interface module includes a payment for the use of the software, including documentation, on the "Ident Systems Software & Documentation" DVD and the purchaser acquires the right to make copies (copy license) insofar as they are required as part of the customer-specific application or development for the plant. The contract accompanying the DVD pertaining to the use of software products against a one-off payment also applies. SIMATIC RF300 416 System Manual, 07/2016, C79000-G8976-C345-0x Appendix A.3 Connecting cable A.3 Connecting cable In the following chapter, you will find an overview of the connecting cables between the readers and communication modules or PCs. A.3.1 RF3xxR reader (RS-422) with ASM 456 / RF160C / RF170C / RF180C / RF182C Connecting cable with straight connector Figure A-11 Connecting cable between ASM 456, RF160C, RF170C, RF180C, RF182C and RF3xxR reader (RS-422) Table A- 3 Ordering data Length L Article number 2m 6GT2891-4FH20 5m 6GT2891-4FH50 10 m 6GT2891-4FN10 20 m 6GT2891-4FN20 50 m 6GT2891-4FN50 SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 417 Appendix A.3 Connecting cable Connecting cable with angled connector Figure A-12 Connecting cable between ASM 456, RF160C, RF170C, RF180C and RF3xxR reader (RS-422) with angled connector Table A- 4 Ordering data Length L Article number 2m 6GT2891-4JH20 5m 6GT2891-4JH50 10 m 6GT2891-4JN10 The angled connector has a height of h = 29 mm and a length of l = 38 mm. Remember that due to the construction, the distance between the edge of the connector and the edge of the reader housing (H) is higher. Figure A-13 Distance between connector edge and housing edge The distance between the connector edge and the housing edge of the reader (H) depends on the reader being used and can be up to 38 mm. If you look at the front of the reader, the angled connector always points to the right and runs parallel to the housing. SIMATIC RF300 418 System Manual, 07/2016, C79000-G8976-C345-0x Appendix A.3 Connecting cable A.3.2 Reader RF3xxR (RS422) with ASM 475 Reader connection system The connecting cable has a length of 2 m (standard) and 5 m. Extensions up to 1000 m are possible with the 6GT2891-4E… plug-in cables. Figure A-14 Structure of the connecting cable between ASM 475 and RF3xx reader with RS-422 Table A- 5 Ordering data Length L Article number 2m 6GT2891-4EH20 5m 6GT2891-4EH50 SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 419 Appendix A.3 Connecting cable A.3.3 Reader RF3xxR (RS-422) with RF120C Figure A-15 Connecting cable between RF120C and RF3xxR reader (RS-422) Table A- 6 Ordering data Length L Article number 2m 6GT2091-4LH20 5m 6GT2091-4LH50 10 m 6GT2091-4LN10 SIMATIC RF300 420 System Manual, 07/2016, C79000-G8976-C345-0x Appendix A.3 Connecting cable A.3.4 Reader RF380R (RS232) - PC The connecting cables have a length of 5 m. The outgoing cable for the power supply has a length of 0.5 m. With 4-pin power supply connector Figure A-16 Connecting cable between PC and RF380R (RS-232) with 4-pin power supply connector Suitable power supply unit: e.g. wide-range power supply unit With open ends for the power supply Figure A-17 Connecting cable between PC and RF380R (RS-232) with open ends for the power supply SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 421 Appendix A.3 Connecting cable Table A- 7 Ordering data connecting cable Article number Connecting cable with 4-pin power supply connector (5 m) 6GT2891-4KH50 Connecting cable with open ends (5 m) 6GT2891-4KH50-0AX0 Table A- 8 Ordering data for wide-range power supply unit Article number Wide-range power supply unit for SIMATIC RF-systems (100 - 240 VAC / 24 VDC / 3 A) with 2 m connecting cable with country-specific plug EU: 6GT2898-0AA00 UK: 6GT2898-0AA10 US: 6GT2898-0AA20 SIMATIC RF300 422 System Manual, 07/2016, C79000-G8976-C345-0x Appendix A.4 Ordering data A.4 Ordering data RF300 components Note Product update Note that readers with the article numbers "6GT2801-xABxx" are being replaced by readers with the article numbers "6GT2801-xBAxx". Table A- 9 RF300 reader Reader RF310R (RS-422) RF310R (Scanmode) RF310R second generation RF340R Description • With RS422 interface (3964R) • IP67 • Operating temperature: -25 °C ... +70 °C • Dimensions (L x W x H): 55 x 75 x 30 mm • with integrated antenna • ISO 15693 compatible • with RS-422 interface (Scanmode) • IP67 • Operating temperature: -25 °C ... +70 °C • Dimensions (L x W x H): 55 x 75 x 30 mm • with integrated antenna • ISO 15693 compatible • With RS-422 interface (3964R) • IP67 • Operating temperature: -25 °C ... +70 °C • Dimensions (L x W x H): 55 x 75 x 30 mm • with integrated antenna • ISO 15693 compatible • With RS422 interface (3964R) • IP67 • Operating temperature -25 °C ... +70 °C • Dimensions (L x W x H): 75 x 75 x 41 mm • with integrated antenna • ISO 15693 compatible Article number horizontal base plate 6GT2801-1AB10 base plate turned through 90° 6GT2801-1AB10-0AX1 6GT2801-1AB20-0AX1 6GT2801-1BA10 6GT2801-2AB10 SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 423 Appendix A.4 Ordering data Reader Description RF340R second generation • With RS-422 interface (3964R) • IP67 • Operating temperature -25 °C ... +70 °C RF350R • Dimensions (L x W x H): 75 x 75 x 41 mm • with integrated antenna • ISO 15693 compatible • With RS-422 interface (3964R) Article number 6GT2801-2BA10 6GT2801-4AB10 • IP65 • Operating temperature: -25 °C ... +70 °C • Dimensions (L x W x H): 75 x 75 x 41 mm • Reader for external antennas, with the option of connecting ANT 1, ANT 3, ANT 12, ANT 18, ANT 30 RF350R second generation • ISO 15693 compatible • With RS422 interface (3964R) • IP65 • Operating temperature: -25 °C ... +70 °C • Dimensions (L x W x H): 75 x 75 x 41 mm • Reader for external antennas, with the option of connecting 6GT2801-4BA10 ANT 1, ANT 3, ANT 12, ANT 18, ANT 30 RF380R RF380R Scanmode • ISO 15693 compatible • with RS-422 interface (3964R) and RS-232 interface (3964R) • IP67 • Operating temperature: -25 °C ... +70 °C • Dimensions (L x W x H): 160 x 80 x 41 mm • with integrated antenna • ISO 15693 compatible • with RS-422 interface (Scanmode) and RS-232 interface (Scanmode) • IP67 • Operating temperature: -25 °C ... +70 °C • Dimensions (L x W x H): 160 x 80 x 41 mm • with integrated antenna • ISO 15693 compatible 6GT2801-3AB10 6GT2801-3AB20-0AX1 SIMATIC RF300 424 System Manual, 07/2016, C79000-G8976-C345-0x Appendix A.4 Ordering data Reader Description RF382R (Scanmode) • with RS-422 interface (Scanmode) and RS-232 interface (Scanmode) • IP67 • Operating temperature: -25 °C ... +70 °C RF350M RF350M • Dimensions (L x W x H): 160 x 80 x 41 mm • with integrated antenna • ISO 15693 compatible • IP54 • Operating temperature: -20 °C ... +55 °C • Dimensions (L x W x H): 250 x 90 x 47 mm • Mobile reader with integrated antenna • IP54 • Operating temperature: -20 °C ... +55 °C • Dimensions (L x W x H): 250 x 90 x 47 mm • Mobile reader for external antennas, with the option of connecting Article number 6GT2801-3AB20-0AX0 6GT2803-1BA00 6GT2803-1BA10 ANT 8, ANT 12, ANT 18, ANT 30 Table A- 10 RF300 transponder RF300 transponder Description RF320T • IP67 • Memory size: 20 bytes of EEPROM user memory • Operating temperature: -25 °C ... +85 °C • Dimensions (Ø x H): 27 x 4 mm • IP68 • Memory size: 32 KB FRAM user memory • Operating temperature: -25 °C ... +85 °C • Dimensions (Ø x H): 30 x 8 mm • IP68 • Memory size: 8 KB FRAM user memory • Operating temperature: -25 °C ... +85 °C • Dimensions (L x W x H): 48 x 25 x 15 mm • IP68 RF330T RF340T (8 KB FRAM) RF340T (32 KB FRAM) • Memory size: 32 KB FRAM user memory • Operating temperature: -25 °C ... +85 °C • Dimensions (L x W x H): 48 x 25 x 15 mm Article number 6GT2800-1CA00 6GT2800-5BA00 6GT2800-4BB00 6GT2800-5BB00 SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 425 Appendix A.4 Ordering data RF300 transponder Description RF350T • IP68 • Memory size: 32 KB FRAM user memory • Operating temperature: -25 °C ... +85 °C • Dimensions (L x W x H): 50 x 50 x 20 mm • IP67 • Memory size: 8 KB FRAM user memory • Operating temperature: -25 °C ... +75 °C • Dimensions (L x W x H): 85.8 x 54.8 x 2.5 mm • IP67 • Memory size: 32 KB FRAM user memory • Operating temperature: -25 °C ... +75 °C • Dimensions (L x W x H): 85.8 x 54.8 x 2.5 mm • IP68 • Memory size: 32 KB FRAM user memory • Operating temperature: -25 °C ... +85 °C • Dimensions (L x W x H): 75 x 75 x 41 mm • IP68 RF360T (8 KB FRAM) RF360T (32 KB FRAM) RF370T (32 KB FRAM) RF370T (64 KB FRAM) RF380T Table A- 11 MDS D117 6GT2800-4AC00 6GT2800-5AC00 6GT2800-5BE00 6GT2800-6BE00 • Memory size: 64 KB FRAM user memory • Operating temperature: -25 °C ... +85 °C • Dimensions (L x W x H): 75 x 75 x 41 mm • IP68 • Memory size 32 KB FRAM user memory • Operating temperature: -25 °C ... +200 °C (cyclic) • Dimensions (Ø x H): 114 x 83 mm 6GT2800-5DA00 ISO transponder ISO transponder MDS D100 Article number 6GT2800-5BD00 Description Article number 6GT2600-0AD10 • IP68 • Memory size: 112 bytes of EEPROM user memory • Operating temperature: -25 °C ... +80 °C • Dimensions (L x W x H): 85.6 x 54 x 0.9 mm • Credit card format • IP68 • Memory size: 112 bytes of EEPROM user memory • Operating temperature: -25 °C ... +85 °C • Dimensions (Ø x H): 4 x 5 mm 6GT2600-0AG00 SIMATIC RF300 426 System Manual, 07/2016, C79000-G8976-C345-0x Appendix A.4 Ordering data ISO transponder Description MDS D124 • IP67; IPx9K • Memory size: 112 bytes of EEPROM user memory • Operating temperature: -25 °C ... +180 °C • Dimensions (Ø x H): 27 (±0.2) x 4 (±0.2) mm • IP68 • Memory size: 112 bytes of EEPROM user memory • Operating temperature: -25 °C ... +85 °C • Dimensions (Ø x H): 50 x 3.6 mm • Round design with mounting hole • IP68; IPx9K • Memory size: 112 bytes of EEPROM user memory • Operating temperature: -25 °C ... +125 °C • Dimensions (Ø x H): M6 x 5.8 (±0.2) mm • IP68; IPx9K • Memory size: 112 bytes of EEPROM user memory • Operating temperature: up to +200 °C/+220 °C • Dimensions (Ø x H): 85 (±0.5) x 15 (-1.0) mm • IP68; IPx9K • Memory size: 112 bytes of EEPROM user memory • Operating temperature: -25 °C...+70 °C • Dimensions (Ø x H): 16 (±0.2) x 3.0 (±0.2) mm • Laundry transponder for cyclic applications • IP65 • Memory size: 112 bytes of EEPROM user memory • Operating temperature: -25 °C ... +85 °C • Dimensions (L x W): 86 x 54 mm • Smartlabel (PET) in credit card format • IP67 • Memory size: 256 bytes of EEPROM user memory • Operating temperature: -20 °C ... +60 °C • Dimensions (L x W x H): 86 x 54 x 0.8 mm • Credit card format • IP65 • Memory size: 256 bytes of EEPROM user memory • Operating temperature: -25 °C ... +85 °C • Dimensions (L x W): 55 x 55 mm • Smartlabel (PET), small design MDS D126 MDS D127 MDS D139 MDS D160 MDS D165 MDS D200 MDS D261 Article number 6GT2600-0AC10 6GT2600-0AE00 6GT2600-0AF00 6GT2600-0AA10 6GT2600-0AB10 6GT2600-1AB00-0AX0 6GT2600-1AD00-0AX0 6GT2600-1AA00-0AX0 SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 427 Appendix A.4 Ordering data ISO transponder Description MDS D324 • IP67; IPx9K • Memory size: 992 bytes of EEPROM user memory • Operating temperature: -25 °C...+125 °C • Dimensions (Ø x H): 27 (±0.2) x 4 (±0.2) mm • IP68; IPx9K • Memory size: 992 bytes of EEPROM user memory • Operating temperature: -25 °C ... +220 °C • Dimensions (Ø x H): 85 (±0.5) x 15 (-1.0) mm • IP67 • Memory size: 2000 bytes of FRAM user memory • Operating temperature: -25 °C ... +60 °C • Dimensions (L x W x H) 85.6 (±0.3) × 54 (±0.2) × 0.8 (±0.05) mm • IP67; IPx9K • Memory size: 2000 bytes of FRAM user memory • Operating temperature –25 °C ... +85 °C • Dimensions (Ø x H): 10 x 4.5 mm • IP68 MDS D339 MDS D400 MDS D421 MDS D422 MDS D423 MDS D424 MDS D425 • Memory size: 2000 bytes of FRAM user memory • Operating temperature: -25 °C ... +85 °C • Dimensions (Ø x H): M20 x 6 (±0.2) mm • Can be screwed into metal (flush-mounted) • IP68; IPx9K • Memory size: 2000 bytes of FRAM user memory • Operating temperature: -25 °C ... +85 °C • Dimensions (Ø x H): 30 (+0.2/-0.5) x 8 (-0.5) mm • IP67; IPx9K • Memory size: 2000 bytes of FRAM user memory • Operating temperature: -25 °C ... +125 °C • Dimensions (Ø x H): 27 (±0.2) x 4 (±0.2) mm • IP68; IPx9K • Memory size: 2000 bytes of FRAM user memory • Operating temperature: -25 °C ... +85 °C • Dimensions (Ø x H): 24 X 10 mm; M6 thread • Screw transponder Article number 6GT2600-3AC00 6GT2600-3AA10 6GT2600-4AD00 6GT2600-4AE00 6GT2600-4AF00 6GT2600-4AA00 6GT2600-4AC00 6GT2600-4AG00 SIMATIC RF300 428 System Manual, 07/2016, C79000-G8976-C345-0x Appendix A.4 Ordering data ISO transponder Description MDS D426 • IP68 • Memory size: 2000 bytes of FRAM user memory • Operating temperature: -25 °C ... +85 °C • Dimensions (Ø x H): 50 x 3.6 mm • Round design with mounting hole • IP68; IPx9K • Memory size: 2000 bytes of FRAM user memory • Operating temperature: -25 °C...+85 °C • Dimensions (Ø x H): 18(±1) x 20(±1) mm (without thread); thread M8 • IP68; IPx9K MDS D428 MDS D460 MDS D521 MDS D522 MDS D522 Special variant MDS D524 MDS D525 • Memory size: 2000 bytes of FRAM user memory • Operating temperature: -25 °C...+85 °C • Dimensions (Ø x H): 16 (±0.2) x 3.0 (±0.2) mm • IP67; IPx9K • Memory size: 8192 bytes of FRAM user memory • Operating temperature –25 °C ... +85 °C • Dimensions (Ø x H): 10 x 4.5 mm • IP68 • Memory size: 8192 bytes of FRAM user memory • Operating temperature: -25 °C ... +85 °C • Dimensions (Ø x H): M20 x 6 (±0.2) mm • Can be screwed into metal (flush-mounted) • IP68 • Memory size: 8192 bytes of FRAM user memory • Operating temperature: -25 °C ... +85 °C • Dimensions (Ø x H): 18 (+0.1) x 5.2 mm • Can be clipped into metal (flush-mounted) • IP67 • Memory size: 8192 bytes of FRAM user memory • Operating temperature: -25 °C ... +85 °C • Dimensions (Ø x H): 27 (±0.2) x 4 (±0.2) mm • IP67; IPx9K • Memory size: 8192 bytes of FRAM user memory • Operating temperature: -25 °C ... +85 °C • Dimensions (Ø x H): 24 x 10 (+1.0) mm Article number 6GT2600-4AH00 6GT2600-4AK00-0AX0 6GT2600-4AB00 6GT2600-5AE00 6GT2600-5AF00 6GT2600-5AF00-0AX0 6GT2600-5AC00 6GT2600-5AG00 SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 429 Appendix A.4 Ordering data ISO transponder Description MDS D526 • IP67; IPx9K • Memory size: 8192 bytes of FRAM user memory • Operating temperature: -25 °C ... +85 °C • Dimensions (Ø x H): 50 x 3.6 mm • Round design with mounting hole • IP68; IPx9K • Memory size: 8192 bytes of FRAM user memory • Operating temperature: -25 °C ... +85 °C • Dimensions (Ø x H): 18(±1) x 20(±1) mm (without thread); thread M8 MDS D528 Table A- 12 Article number 6GT2600-5AH00 6GT2600-5AK00 Communication modules/interface modules Communications module Description Article number ASM 456 ASM 456 for PROFIBUS DP-V1 max. 2 readers connectable 6GT2002-0ED00 ASM 475 ASM 475 for SIMATIC S7 max. 2 RF3xxR readers with RS-422 can be connected in parallel without a front connector 6GT2002-0GA10 RF120C Communications module RF120C for SIMATIC S7-1200 6GT2002-0LA00 RF160C Communications module RF160C for PROFIBUS DP V0 max. 2 readers connectable 6GT2002-0EF00 RF170C RF170C communications module 6GT2002-0HD00 RF170C connecting block 6GT2002-1HD00 RF180C communications module max. 2 SLGs or readers can be connected 6GT2002-0JD00 Connecting block M12, 7/8'' (5-pin) 6GT2002-1JD00 Connecting block M12, 7/8'' (4-pin) 6GT2002-4JD00 Push-pull connecting block, RJ-45 6GT2002-2JD00 RF182C communications module 6GT2002-0JD10 RF180C RF182C max. 2 SLGs or readers can be connected RFID 181EIP Connecting block M12, 7/8'' (5-pin) 6GT2002-1JD00 Connecting block M12, 7/8'' (4-pin) 6GT2002-4JD00 Push-pull connecting block, RJ-45 6GT2002-2JD00 RF182C communications module max. 2 SLGs or readers can be connected 6GT2002-0JD20 Connecting block M12, 7/8'' (5-pin) 6GT2002-1JD00 Connecting block M12, 7/8'' (4-pin) 6GT2002-4JD00 Push-pull connecting block, RJ-45 6GT2002-2JD00 SIMATIC RF300 430 System Manual, 07/2016, C79000-G8976-C345-0x Appendix A.4 Ordering data Table A- 13 Antennas Antenna Description ANT 1 • IP67 ANT 3 ANT 3S ANT 8 ANT 12 ANT 18 ANT 30 • Operating temperature: -25 °C ... +70 °C • Dimensions (L x W x H): 75 x 75 x 20 mm • incl. an integrated antenna cable 3 m • IP67 Article number 6GT2398-1CB00 6GT2398-1CD30-0AX0 • Operating temperature: -25 °C ... +70 °C • Dimensions (L x W x H): 50 x 28 x 10 mm • without antenna connecting cable • incl. one plug-in antenna connecting cable 3 m 6GT2398-1CD40-0AX0 • IP67 6GT2398-1CD50-0AX0 • Operating temperature: -25 °C ... +70 °C • Dimensions (L x W x H): 50 x 28 x 10 mm • without antenna connecting cable • incl. one plug-in antenna connecting cable 3 m 6GT2398-1CD60-0AX0 • IP67 6GT2398-1CF00 • Operating temperature: -25 °C ... +70 °C • Dimensions (Ø x L): M8 x 40 mm • without antenna connecting cable • incl. one plug-in antenna connecting cable 3 m 6GT2398-1CF10 • IP67 6GT2398-1CC00 • Operating temperature: -25 °C ... +70 °C • Dimensions (Ø x L): M12 x 40 mm • incl. one plug-in antenna connecting cable 3 m • IP67 (front) • Operating temperature: -25 °C ... +70 °C • Dimensions (Ø x L): M18 x 55 mm • incl. one plug-in antenna connecting cable 3 m • IP67 • Operating temperature: -25 °C ... +70 °C • Dimensions (Ø x L): M30 x 58 mm • incl. one plug-in antenna connecting cable 3 m 6GT2398-1CA00 6GT2398-1CD00 SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 431 Appendix A.4 Ordering data Accessories Table A- 14 Accessories for RF300 reader Reader Accessories Article number RF380R RS-232 plug-in cable with 4-pin connector 6GT2891-4KH50 Plug-in cable RS-232 with open ends (5 m) 6GT2891-4KH50-0AX0 Plug-in cable with D-SUB ↔ M12, 8-pin and with M8, 3-pin power unit connector 6GT2891-4KH50-0AX1 Table A- 15 RF300 transponder accessories Transponder Accessories Article number RF320T Spacer (Ø x H): 36 x 22 mm 6GT2690-0AK00 RF330T Fixing hood (L x W x H): 49.4 x 20 x 9.8 mm 6GT2690-0EA00 RF360T Spacer (L x W x H): 110 x 62 x 24 mm (in conjunction with fixing pocket 6GT2190-0AB00) 6GT2190-0AA00 Fixing pocket (L x W x H): 121 x 57 x 5 mm (in conjunction with spacer 6GT2190-0AA00) 6GT2190-0AB00 Holder (short version) 6GT2090-0QA00 Holder (long version) 6GT2090-0QA00-0AX3 Shrouding cover 6GT2090-0QB00 Universal holder 6GT2590-0QA00 RF380T Table A- 16 Transponder accessories Transponder Accessories Article number MDS D100 / D200 / D400 / D600 / D611 Spacer 6GT2190-0AA00 Fixing pocket 6GT2190-0AB00 Securing pocket (cannot be mounted directly on metal) 6GT2390-0AA00 Spacer (Ø x H): 85 x 30 mm 6GT2690-0AA00 Quick change holder (Ø x H): 22 x 60 mm 6GT2690-0AH00 Quick change holder (Ø x H): 22 x 47 mm 6GT2690-0AH10 MDS D124 / D324 / D424 / D524 Spacer (Ø x H): 36 x 22 mm 6GT2690-0AK00 MDS D126 / D426 / D526 / E624 Spacer (Ø x H): 59 x 30 mm 6GT2690-0AL00 MDS D160 / D460 Spacer (Ø x H): 20 x 14 mm 6GT2690-0AG00 MDS D423 / RF330T Spacer (L x W x H): 49.4 x 20 x 9.8 mm 6GT2690-0EA00 MDS D139 / D339 SIMATIC RF300 432 System Manual, 07/2016, C79000-G8976-C345-0x Appendix A.4 Ordering data Table A- 17 Accessory connecting RF300 reader ↔ PC Connecting cable Accessories Article number RF240R / RF260R / RF290R (RS232) Connecting cable RS-232 with M12 male connector (4-pin), 5 m 6GT2891-4KH50 and PC Connecting cable RS-232 with open ends, 5 m 6GT2891-4KH50-0AX0 Table A- 18 Accessories - connecting cable communications module/ASM ↔ reader Connecting cables Description Article number Length ASM 456 / RF160C / RF170C / RF180C 2m 6GT2891-4FH20 and reader RF3xxR (RS422) 5m 6GT2891-4FH50 10 m 6GT2891-4FN10 20 m 6GT2891-4FN20 50 m 6GT2891-4FN50 ASM 456 / RF160C / RF170C / RF180C 2m 6GT2891-4JH20 and RF3xxR reader (RS-422) with angled connector 5m 6GT2891-4JH50 10 m 6GT2891-4JN10 ASM 475 2m 6GT2891-4EH20 and reader RF3xxR (RS422) 5m 6GT2891-4EH50 RF120C 2m 6GT2091-4LH20 and reader RF3xxR (RS422) 5m 6GT2091-4LH50 10 m 6GT2091-4LN10 Table A- 19 RFID accessories, general RFID general Article number DVD "Ident Systems Software & Documentation" 6GT2080-2AA20 Wide-range power supply unit for SIMATIC RF systems (100 - 240 VAC / 24 VDC / 3 A) with country-specific power cable/plug, 2 m EU: 6GT2898-0AC00 UK: 6GT2898-0AC10 US: 6GT2898-0AC20 24 V connecting cable, 5 m 6GT2491-1HH50 M12 connector, 4-pin for wide range power supply unit, pack of 3 6GK1907-0DB106AA3 SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 433 Appendix A.5 Service & Support A.5 Service & Support Technical Support You can reach technical support for all PD projects as follows: ● Phone: + 49 (0) 911 895 7222 ● Fax: + 49 (0) 911 895 7223 ● E-mail (mailto:support.automation@siemens.com) ● Internet: Web form for Support Request (https://support.industry.siemens.com/My/ww/en/requests) Contacts If you have any further questions on the use of our products, please contact one of our representatives at your local Siemens office. The addresses are found on the following pages: ● On the Internet (http://w3.siemens.com/aspa_app) ● In Catalog CA 01 ● In the catalog ID 10 specially for Industrial Identification Systems Service & Support for Process Industries and Drives On the Internet, on the Support home page (https://support.industry.siemens.com/cs/de/en/) of Process Industries and Drives (PD), you will find various services. There you will find the following information, for example: ● Our newsletter containing up-to-date information on your products. ● Relevant documentation for your application, which you can access via the search function in "Product Support". ● A forum for global information exchange by users and specialists. ● Your local contact for PD. ● Information about on-site service, repairs, and spare parts. Much more can be found under "Our service offer". RFID homepage For general information about our identification systems, visit RFID homepage (http://w3.siemens.com/mcms/identification-systems/). Online catalog and ordering system The online catalog and the online ordering system can also be found on the Industry Mall Homepage (https://mall.industry.siemens.com). SIMATIC RF300 434 System Manual, 07/2016, C79000-G8976-C345-0x Appendix A.5 Service & Support Training center We offer appropriate courses to get you started. Please contact your local training center or the central training center in D-90327 Nuremberg. Phone: +49 (0) 180 523 56 11 (€ 0.14 /min. from the German landline network, deviating mobile communications prices are possible) For information about courses, see the SITRAIN homepage (http://sitrain.automation.siemens.com/sitrainworld/). SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 435 Appendix A.5 Service & Support SIMATIC RF300 436 System Manual, 07/2016, C79000-G8976-C345-0x Index Antennas Minimum clearances, 200 Application Planning SIMATIC RF300, 37 Approvals, 405 ASM 475 Assignment for connecting cable, 386, 419 Cable installation, 387 Design and function, 382 Function of the LEDs, 385 Indicators, 385 Ordering data, 383 Pin assignment, 386, 419 Status display with LEDs, 385 Dwell time Transponder, 46 Dynamic mode, 45 Dwell time of the transponder, 46 Electromagnetic compatibility Coupling paths, 104 Electromagnetic interference, 102 EMC directives Definition, 100 Equipotential bonding, 110 EMC Directives Propagation of electromagnetic interference, 102 EMC Guidelines Avoiding interference, 109 Basic Rules, 101 Cabinet configuration, 106 Cable shielding, 111 Overview, 99 Equipotential bonding, 110 Error codes Reader, 395 Cabinet configuration, 106 Cable, 417 Reader - ASM, 417 Shielding, 111 Certificates, 405 Communication modules, 379 Communication time Calculation, 47 Connecting cable Reader-communication module/ASM/PC, 417 Contacts, 434 Coupling paths, 104 Courses, 435 Customer benefits, 31 FC 45, 397 Field data ISO transponder, 52, 57 RF300 transponder, 49 Fields of application, 31 Flush-mounting of transponders and readers, 63 Detection area, 44 Diagnostic functions Transponder, 401 Direction of motion Transponder, 44 Display elements RF310R reader with RS-422 interface, 116 RF340R reader, 137 RF350R reader, 144, 167 High-performance, 22 Inductive alternating field, 37 Input parameter, 379 Installation Several readers, 64 Installation guidelines, 62 SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 437 Index Interface modules, 379 Interference sources Electromagnetic, 103 ISO 14443 functionality, 114 ISO 15693 functionality, 113 ISO transponder Resistance to chemicals, 90 Main applications, 31 MDS D100 transponder Technical specifications, 256 MDS D117 transponder Technical specifications, 260 MDS D124 Transponder Technical specifications, 264 MDS D127 transponder Technical specifications, 274 MDS D160 transponder Technical specifications, 285 MDS D200 transponder Technical specifications, 293 MDS D339 transponder Technical specifications, 305 MDS D424 Transponder Technical specifications, 332 MDS D425 Transponder Technical specifications, 335 MDS D428 transponder Technical specifications, 343 MDS D460 Transponder Technical specifications, 347 MDS D521 transponder Technical specifications, 353 MDS D522 transponder Technical specifications, 356 MDS D524 transponder Technical specifications, 365 MDS D525 transponder Technical specifications, 368 MDS D526 transponder Technical specifications, 373 MDS D528 transponder Technical specifications, 376 MDS STATUS, 397 Medium-performance, 22 Memory configuration of the RF300 transponders, 208 Metal Influence on the transmission window, 65 Metal-free area Reader RF310R, 117, 124 Reader RF340R, 138 RF380R reader, 168, 177 Transponder RF330T, 216 Transponder RF340T, 221 Transponder RF350T, 224 Transponder RF360T, 229 Transponder RF370T, 235 Transponder RF380T, 242 Metal-free space RF310R reader, 131 RF340R reader, 154 Minimum clearances Antenna to antenna, 200 Minimum distance Antenna to antenna, 61 Reader to reader, 60 Transponder to transponder, 59 Ordering data, 423 Antennas, 196, 431 Communications modules, 430 ISO transponder, 426 Overview, 423 Reader, 423 RF300 transponder, 425 RF310R Scanmode, 122 RF310R with RS-422 interface, 115, 129 RF340R with RS-422 interface, 136, 152 RF350R with RS-422 interface, 143, 159 RF380R Scanmode, 175 RF380R with RS-422 interface, 166 RF382R Scanmode, 182 Parameterization Function blocks, 379 Possible combinations Reader - transponder, 24, 27, 30 Read/write distance, 37 Reader Installing, 64 Reader RF310R Metal-free area, 117, 124 Reader RF340R Metal-free area, 138 SIMATIC RF300 438 System Manual, 07/2016, C79000-G8976-C345-0x Index Reducing interference due to metal, 62 Reduction of field data by metal RF310R, 65 RF340R, 69 RF350R with ANT 1, 73 RF350R with ANT 18, 80 RF350R with ANT 3, 76 RF350R with ANT 30, 83 RF380R, 85 RF382R, 89 Resistance to chemicals Transponder, 90 RF300 system diagnostics SLG STATUS, 398 RF300 transponder Resistance to chemicals, 90 RF310R reader, 115, 122, 129 Characteristics, 115, 122, 129 Metal-free space, 131 RF330T Characteristics, 215 RF340R reader, 136, 152 Characteristics, 136, 152 Metal-free space, 154 RF350R reader, 143, 159 Characteristics, 143, 159 RF380R reader, 166 Characteristics, 166 Metal-free area, 168, 177 RF380R Scanmode reader, 175 Characteristics, 175 RFID systems Overview, 21 Scanmode, 22 Selection criteria SIMATIC RF300 components, 37 Shielding, 111 SLG STATUS, 397 Static mode, 45 Dwell time of the transponder, 46 Structure System manual, 13 System diagnostics MDS status, 401 System overview RFID systems, 21 Technical specifications MDS D100 transponder, 256 MDS D117 transponder, 260 MDS D124 Transponder, 264 MDS D127 transponder, 274 MDS D160 transponder, 285 MDS D200 transponder, 293 MDS D339 transponder, 305 MDS D424 Transponder, 332 MDS D425 Transponder, 335 MDS D428 transponder, 343 MDS D460 Transponder, 347 MDS D521 transponder, 353 MDS D522 transponder, 356 MDS D524 transponder, 365 MDS D525 transponder, 368 MDS D526 transponder, 373 MDS D528 transponder, 376 Transponder MDS D126, 270 Transponder MDS D139, 279 Transponder MDS D165, 289 Transponder MDS D261, 297 Transponder MDS D324, 301 Transponder MDS D400, 312 Transponder MDS D421, 318 Transponder MDS D422, 323 Transponder MDS D423, 327 Transponder MDS D426, 340 Transponder RF320T, 213 Transponder RF330T, 217 Transponder RF340T, 222 Transponder RF350T, 227 Transponder RF360T, 232 Transponder RF370T, 236 Transponder RF380T, 247 Technical Support, 434 Tracking Tolerance, 40 Tracking tolerances, 40 Training, 435 Transmission gaps, 48 Transmission window Antennas, 39 Impact of metal, 65 Reader, 38 Width, 40 Transponder Detection area, 44 Directions of motion, 44 Dwell time, 46 Mounting on metal, 64 SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 439 Index Transponder MDS D126 Technical specifications, 270 Transponder MDS D139 Technical specifications, 279 Transponder MDS D165 Technical specifications, 289 Transponder MDS D261 Technical specifications, 297 Transponder MDS D324 Technical specifications, 301 Transponder MDS D400 Technical specifications, 312 Transponder MDS D421 Technical specifications, 318 Transponder MDS D422 Technical specifications, 323 Transponder MDS D423 Technical specifications, 327 Transponder MDS D426 Technical specifications, 340 Transponder RF320T Characteristics, 211 Technical specifications, 213 Transponder RF330T Characteristics, 215 Metal-free area, 216 Technical specifications, 217 Transponder RF340T Characteristics, 220 Metal-free area, 221 Technical specifications, 222 Transponder RF350T Characteristics, 224 Metal-free area, 224 Technical specifications, 227 Transponder RF360T Characteristics, 229 Metal-free area, 229 Technical specifications, 232 Transponder RF370T Characteristics, 234 Metal-free area, 235 Technical specifications, 236 Transponder RF380T Metal-free area, 242 Technical specifications, 247 User data Calculation, 47 SIMATIC RF300 440 System Manual, 07/2016, C79000-G8976-C345-0x
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : SIEMENS AG Create Date : 2016:07:12 09:45:24+02:00 Keywords : Draft, Document!, Note:, This, document, is, a, draft, document., This, document, is, not, released, for, publication., Siemens, accepts, no, liability, for, the, completeness, and, correctness, of, the, contents. Modify Date : 2016:08:01 12:00:28+02:00 Has XFA : No Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Metadata Date : 2016:08:01 12:00:28+02:00 Creator Tool : Acrobat PDFMaker 11 für Word Document ID : uuid:b70fa864-d883-4fd1-bf2f-f4a77846d359 Instance ID : uuid:2c2c93d2-fe0d-4e38-97e7-2b479d040162 Format : application/pdf Title : SIMATIC RF300 Description : SIMATIC Ident Creator : SIEMENS AG Subject : Draft Document!, Note: This document is a draft document. This document is not released for publication. Siemens accepts no liability for the completeness and correctness of the contents. Producer : Adobe PDF Library 11.0 Source Modified : D:20160712074354 Company : Siemens AG Comments : Edition : 0.00347222222222222 System : SIMATIC Ident Print-year : 2005 - 2016 Document-class : System Manual Document-class-mrl : Product-group : RFID systems Order-nr : C79000-G8976-C345-0x Ident-nr : Company-short : Siemens Company-long : Siemens AG Headline : System Manual Page Layout : OneColumn Page Mode : UseOutlines Page Count : 36EXIF Metadata provided by EXIF.tools