Siemens RF340R02 RFID Reader 13.56 MHz User Manual SIMATIC RF300

Siemens AG RFID Reader 13.56 MHz SIMATIC RF300

User Manual part 3

Download: Siemens RF340R02 RFID Reader 13.56 MHz User Manual SIMATIC RF300
Mirror Download [FCC.gov]Siemens RF340R02 RFID Reader 13.56 MHz User Manual SIMATIC RF300
Document ID3093597
Application IDXROHsdVJjXSnUkfJOrWqEA==
Document DescriptionUser Manual part 3
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize105.67kB (1320847 bits)
Date Submitted2016-08-10 00:00:00
Date Available2016-08-17 00:00:00
Creation Date2016-07-12 09:45:24
Producing SoftwareAdobe PDF Library 11.0
Document Lastmod2016-08-01 12:00:28
Document TitleSIMATIC RF300
Document CreatorAcrobat PDFMaker 11 für Word
Document Author: SIEMENS AG

Appendix
A.1
Certificates and approvals
All the latest RFID radio approvals are available on the Internet
(http://www.siemens.com/rfid-approvals).
Labeling
Description
Conformity acc. to the RED EU directive
Notes on CE marking
The following applies to the system described in this documentation:
The CE marking on a device indicates the corresponding approval.
DIN ISO 9001 certificate
The quality assurance system for the entire product process (development, production, and
marketing) at Siemens fulfills the requirements of ISO 9001 (corresponds to EN29001:
1987).
This has been certified by DQS (the German society for the certification of quality
management systems).
EQ-Net certificate no.: 1323-01
Country-specific approvals
Safety
If the device has one of the following markings the corresponding approval has been
obtained:
Labeling
Description
Underwriters Laboratories (UL) to UL 60950 Standard (I.T.E), UL508
or UL61010-1/UL61010-2-201 (IND.CONT.EQ)
Underwriters Laboratories (UL) according to Canadian standard C22.2
No. 60950 (I.T.E), C22.2 No. 142 or C22.2 NO. 61010-1-12
(IND.CONT.EQ)
Underwriters Laboratories (UL) according to Standard UL 60950,
Report E11 5352 and Canadian standard C22.2 No. 60950 (I.T.E),
UL508 or UL61010-1/UL61010-2-201 (IND.CONT.EQ) and C22.2 No.
142 or C22.2 NO. 61010-1-12 (IND.CONT.EQ)
SIMATIC RF300
System Manual, 07/2016, C79000-G8976-C345-0x
405
Appendix
A.1 Certificates and approvals
Labeling
Description
UL recognition mark
Canadian Standard Association (CSA) acc. to standard C22.2. No.
60950 (LR 81690), C22.2 No. 142 or C22.2 NO. 61010-1-12 (LR
63533)
Canadian Standard Association (CSA) acc. to American Standard UL
60950 (LR 81690), UL508 or UL61010-1/UL61010-2-201 (LR 63533)
This product meets the requirements of the AS/NZS 3548 Norm.
USA (FCC)
This device complies with Part 15 of the FCC Rules.
FCC ID: NXW-RF...
Canada (IC)
Canada (IC)
This device complies with Industry Canada licence-exempt RSS
standard(s).
IC: 267X-RF...
Russia, Belarus and Kazakhstan
Brazil (ANATEL)
ANATEL-ID: XXXX-YY-ZZZZ
Mexico (COFETEL)
Mexico (COFETEL)
South Africa (ICASA)
China (CMIIT)
China (CMIIT)
CMIIT ID: XXXXYYZZZZ
South Korea (KCC)
Japan (VCCI)
SIMATIC RF300
406
System Manual, 07/2016, C79000-G8976-C345-0x
Appendix
A.2 Accessories
A.2
Accessories
A.2.1
Transponder holders
Table A- 1
Overview of the transponder holders and spacers
Product photo
Insertable transponders
•
MDS D100
•
MDS D200
•
MDS D400
•
MDS E600
•
MDS E611
•
RF360T
6GT2190-0AA00
6GT2190-0AB00
•
MDS D100
•
MDS D200
•
MDS D400
•
MDS E600
•
MDS E611
•
RF360T
•
MDS D100
•
MDS D200
•
MDS D400
•
MDS E600
•
MDS E611
Characteristics
•
Spacer for mounting on metal, in conjunction with the
fixing pocket 6GT2190-0AB00
•
Distance from transponder to metal: 25 mm
•
Mounting: 4 x M4 screws
•
Material: PA6
•
Weight: 31 g
•
Dimensions (L x W x H): 110 x 62 x 24 mm
•
Fixing pocket in conjunction with spacer 6GT21900AA00
•
Mounting:
–
Locks into spacer
–
2 x screws/nails
–
Tacked
•
Material: PA6
•
Weight: 12 g
•
Dimensions (L x W x H): 121 x 57 x 5 mm
•
Fixing pocket not suitable for mounting directly on
metal
•
Mounting: 2 x M4 countersunk screws
•
Material: PA6
•
Weight: 21 g
•
Dimensions (L x W x H): 110 x 65 x 5 mm
6GT2390-0AA00
SIMATIC RF300
System Manual, 07/2016, C79000-G8976-C345-0x
407
Appendix
A.2 Accessories
Product photo
Insertable transponders
Characteristics
•
MDS D139
•
Spacer for mounting on metal
•
MDS D339
•
Distance from transponder to metal: 30 mm
•
Mounting: 1 x M5 stainless steel screw
•
Tightening torque: 1.5 Nm
•
Material: PPS
•
Weight: 50 g
•
Dimensions (Ø x H): 85 x 30 mm
6GT2690-0AA00
•
MDS D139
•
Quick change holder for mounting on metal
•
MDS D339
•
Distance from transponder to metal: 30 mm
•
Mounting: Screw-in
6GT2690-0AH00
•
Material: Stainless steel VA
•
Weight: 80 g
•
Dimensions (Ø x H): 22 x 60 mm
•
MDS D139
•
Quick change holder for mounting on metal
•
MDS D339
•
Distance from transponder to metal: 30 mm
•
Mounting: Screw-in
•
Material: Stainless steel VA
•
Weight: 60 g
•
Dimensions (Ø x H): 22 x 47 mm
6GT2690-0AH10
•
MDS D124
•
Spacer for mounting on metal
•
MDS D324
•
Distance from transponder to metal: 15 mm
•
MDS D424
•
Mounting: 1 x M4 countersunk screw
•
MDS D524
•
Tightening torque: ≤ 1 Nm
•
Material: PPS
•
Weight: Approx. 4 g
•
Remounting cycles: min. 10
•
Dimensions (Ø x H): 36 x 22 mm
6GT2690-0AK00
SIMATIC RF300
408
System Manual, 07/2016, C79000-G8976-C345-0x
Appendix
A.2 Accessories
Product photo
Insertable transponders
Characteristics
•
MDS D126
•
Spacer for mounting on metal
•
MDS D426
•
Distance from transponder to metal: 25 mm
•
MDS D526
•
Mounting: 1 x M4 countersunk screw
•
MDS E624
•
Tightening torque: ≤ 1 Nm
•
Material: PA6
•
Weight: Approx. 12 g
•
Remounting cycles: min. 10
•
Dimensions (Ø x H): 59 x 30 mm
6GT2690-0AL00
•
MDS D160
•
Spacer for mounting on metal
•
MDS D460
•
Distance from transponder to metal: 10 mm
•
Mounting: 1 x M3 countersunk screw
•
Material: PA6
•
Weight: 2 g
•
Dimensions (Ø x H): 20 x 14 mm
6GT2690-0AG00
•
MDS D423
•
Fixing hood
•
RF330T
•
Mounting: 2 x M4 or 2 x M5 screws with max. head
diameter of 9.5 mm
•
Tightening torque ≤ 0.8 Nm (M4 only with flat washer)
•
Material: PPS
•
Weight: 3 g
•
Dimensions (L x W x H): 49.4 x 20 x 9.8 mm
6GT2690-0EA00
SIMATIC RF300
System Manual, 07/2016, C79000-G8976-C345-0x
409
Appendix
A.2 Accessories
Dimensional drawings
Figure A-1
Dimension drawing of spacer 6GT2190-0AA00 with fixing pocket 6GT2190-0AB00
Figure A-2
Dimension drawing of fixing pocket 6GT2390-0AA00
SIMATIC RF300
410
System Manual, 07/2016, C79000-G8976-C345-0x
Appendix
A.2 Accessories
Figure A-3
Dimension drawing of spacer 6GT2690-0AA00
Figure A-4
Dimension drawing of quick change holder 6GT2690-0AH00
SIMATIC RF300
System Manual, 07/2016, C79000-G8976-C345-0x
411
Appendix
A.2 Accessories
Figure A-5
Dimension drawing of quick change holder 6GT2690-0AH10
Figure A-6
Dimension drawing of spacer 6GT2690-0AK00
Figure A-7
Dimension drawing of spacer 6GT2690-0AL00
SIMATIC RF300
412
System Manual, 07/2016, C79000-G8976-C345-0x
Appendix
A.2 Accessories
Figure A-8
Dimension drawing of spacer 6GT2690-0AG00
Figure A-9
Dimension drawing of fixing hood 6GT2690-0EA00
SIMATIC RF300
System Manual, 07/2016, C79000-G8976-C345-0x
413
Appendix
A.2 Accessories
A.2.2
MOBY I migration
The RF300 readers of the new generation provide the option of simple migration of existing
MOBY I systems to SIMATIC RF300. The so-called MOBY I emulation processes frames of
the MOBY I protocol on its serial interface and communicates with the established RF300
transponders.
If the RF300 reader is connected to a communications module with MOBY I capability, the
reader automatically recognizes the serial protocol and sets the MOBY I protocol. As a
communications module with MOBY I capability, all the communications modules sold for
MOBY I count regardless of the mode in which the MOBY I communications modules are
operated. This property allows even projects with the ECC mode turned on or with file
handlers to be migrated.
Communication modules with MOBY I capability:
RF180C, RFID 181EIP, RF170C, ASM 456, ASM 475, ASM 470, ASM450, ASM 451, ASM
452, ASM 472, ASM 473, ASM 424, ASM 454, ASM 400, CM 422, CM 423, ASM 410, ASM
420, ASM 421, ASM 440, ES030
With the aid of the adapter cable (0.3 m; article number 6GT2091-4VE30) you can migrate
existing MOBY I projects without needing to re-cable the connected RFID devices.
The transfer is as usual with MOBY I with a transmission speed of 19.2 kBd. The
transmission speed in the application is identical (or slightly slower) than with the original
MOBY I hardware.
NOTICE
Changed field geometry
When replacing MOBY I components with RF300 components note that the field geometry
changes.
SIMATIC RF300
414
System Manual, 07/2016, C79000-G8976-C345-0x
Appendix
A.2 Accessories
Design of the Y adapter
With the aid of the Y adapter (article number 6GT2090-4VE00) a slow migration of a MOBY I
application to RF300 is possible. The Y adapter is mounted in the vicinity of a MOBY I SLG.
It forwards signals of a communications module both to the MOBY I SLG and to the RF300
readers to be newly installed. The transponder commands are handled either with a MOBY I
transponder or with an RF300 transponder. To do this, no change to the MOBY I application
is necessary.
①
②
Power
Optional 24 VDC supply voltage, M12 plug, 4-pin
Connector for the communications module; SLG plug, 6-pin acc. to EN 175201-804
③
④
ASM
TxD
RF300
Connector for RF 300 reader; M12 socket, 8-pin
MOBY l
Connector for the MOBY I reader; SLG socket (angled), plug, 6-pin acc. to EN
175201-804
Figure A-10
= 0.5 m
Connection graphic of the MOBY Y adapter for MOBY I
Command set
The command set of the MOBY I readers is supported by the RF300 readers. You will find a
list of the commands and a description of the commands in the manuals "FB 45" and "FC
56". These manuals can be found in the archive of the DVD "Ident Systems Software &
Documentation" (6GT2080-2AA20).
SIMATIC RF300
System Manual, 07/2016, C79000-G8976-C345-0x
415
Appendix
A.2 Accessories
A.2.3
DVD "Ident Systems Software & Documentation"
The DVD contains:
● FB/FC for SIMATIC, 3964R
● Drivers for DOS/Windows XP/Win 7
● C libraries
● PC demonstration program
● RFID documentation in PDF format, especially RFID system manuals, programming
instructions and operating instructions
Table A- 2
Ordering data DVD
Article number
DVD "Ident Systems Software & Documentation"
6GT2080-2AA20
Note
Notes on "Ident Systems Software" and licensing
When purchasing a communication module or an interface module, no software or
documentation is supplied. The "Ident Systems Software & Documentation" DVD contains all
available FBs/FCs for the SIMATIC, C libraries, demo programs, etc. and needs to be
ordered separately. In addition, the DVD contains the complete Ident documentation
(German and English) in PDF format.
The purchase of a communications module or an interface module includes a payment for
the use of the software, including documentation, on the "Ident Systems Software &
Documentation" DVD and the purchaser acquires the right to make copies (copy license)
insofar as they are required as part of the customer-specific application or development for
the plant.
The contract accompanying the DVD pertaining to the use of software products against a
one-off payment also applies.
SIMATIC RF300
416
System Manual, 07/2016, C79000-G8976-C345-0x
Appendix
A.3 Connecting cable
A.3
Connecting cable
In the following chapter, you will find an overview of the connecting cables between the
readers and communication modules or PCs.
A.3.1
RF3xxR reader (RS-422) with ASM 456 / RF160C / RF170C / RF180C /
RF182C
Connecting cable with straight connector
Figure A-11
Connecting cable between ASM 456, RF160C, RF170C, RF180C, RF182C and RF3xxR
reader (RS-422)
Table A- 3
Ordering data
Length L
Article number
2m
6GT2891-4FH20
5m
6GT2891-4FH50
10 m
6GT2891-4FN10
20 m
6GT2891-4FN20
50 m
6GT2891-4FN50
SIMATIC RF300
System Manual, 07/2016, C79000-G8976-C345-0x
417
Appendix
A.3 Connecting cable
Connecting cable with angled connector
Figure A-12
Connecting cable between ASM 456, RF160C, RF170C, RF180C and RF3xxR reader
(RS-422) with angled connector
Table A- 4
Ordering data
Length L
Article number
2m
6GT2891-4JH20
5m
6GT2891-4JH50
10 m
6GT2891-4JN10
The angled connector has a height of h = 29 mm and a length of l = 38 mm. Remember that
due to the construction, the distance between the edge of the connector and the edge of the
reader housing (H) is higher.
Figure A-13
Distance between connector edge and housing edge
The distance between the connector edge and the housing edge of the reader (H) depends
on the reader being used and can be up to 38 mm. If you look at the front of the reader, the
angled connector always points to the right and runs parallel to the housing.
SIMATIC RF300
418
System Manual, 07/2016, C79000-G8976-C345-0x
Appendix
A.3 Connecting cable
A.3.2
Reader RF3xxR (RS422) with ASM 475
Reader connection system
The connecting cable has a length of 2 m (standard) and 5 m. Extensions up to 1000 m are
possible with the 6GT2891-4E… plug-in cables.
Figure A-14
Structure of the connecting cable between ASM 475 and RF3xx reader with RS-422
Table A- 5
Ordering data
Length L
Article number
2m
6GT2891-4EH20
5m
6GT2891-4EH50
SIMATIC RF300
System Manual, 07/2016, C79000-G8976-C345-0x
419
Appendix
A.3 Connecting cable
A.3.3
Reader RF3xxR (RS-422) with RF120C
Figure A-15
Connecting cable between RF120C and RF3xxR reader (RS-422)
Table A- 6
Ordering data
Length L
Article number
2m
6GT2091-4LH20
5m
6GT2091-4LH50
10 m
6GT2091-4LN10
SIMATIC RF300
420
System Manual, 07/2016, C79000-G8976-C345-0x
Appendix
A.3 Connecting cable
A.3.4
Reader RF380R (RS232) - PC
The connecting cables have a length of 5 m. The outgoing cable for the power supply has a
length of 0.5 m.
With 4-pin power supply connector
Figure A-16
Connecting cable between PC and RF380R (RS-232) with 4-pin power supply connector
Suitable power supply unit: e.g. wide-range power supply unit
With open ends for the power supply
Figure A-17
Connecting cable between PC and RF380R (RS-232) with open ends for the power supply
SIMATIC RF300
System Manual, 07/2016, C79000-G8976-C345-0x
421
Appendix
A.3 Connecting cable
Table A- 7
Ordering data connecting cable
Article number
Connecting cable with 4-pin power supply connector (5 m)
6GT2891-4KH50
Connecting cable with open ends (5 m)
6GT2891-4KH50-0AX0
Table A- 8
Ordering data for wide-range power supply unit
Article number
Wide-range power supply unit for SIMATIC RF-systems
(100 - 240 VAC / 24 VDC / 3 A)
with 2 m connecting cable with country-specific plug
EU: 6GT2898-0AA00
UK: 6GT2898-0AA10
US: 6GT2898-0AA20
SIMATIC RF300
422
System Manual, 07/2016, C79000-G8976-C345-0x
Appendix
A.4 Ordering data
A.4
Ordering data
RF300 components
Note
Product update
Note that readers with the article numbers "6GT2801-xABxx" are being replaced by readers
with the article numbers "6GT2801-xBAxx".
Table A- 9
RF300 reader
Reader
RF310R
(RS-422)
RF310R
(Scanmode)
RF310R
second generation
RF340R
Description
•
With RS422 interface (3964R)
•
IP67
•
Operating temperature: -25 °C ... +70 °C
•
Dimensions (L x W x H): 55 x 75 x 30 mm
•
with integrated antenna
•
ISO 15693 compatible
•
with RS-422 interface (Scanmode)
•
IP67
•
Operating temperature: -25 °C ... +70 °C
•
Dimensions (L x W x H): 55 x 75 x 30 mm
•
with integrated antenna
•
ISO 15693 compatible
•
With RS-422 interface (3964R)
•
IP67
•
Operating temperature: -25 °C ... +70 °C
•
Dimensions (L x W x H): 55 x 75 x 30 mm
•
with integrated antenna
•
ISO 15693 compatible
•
With RS422 interface (3964R)
•
IP67
•
Operating temperature -25 °C ... +70 °C
•
Dimensions (L x W x H): 75 x 75 x 41 mm
•
with integrated antenna
•
ISO 15693 compatible
Article number
horizontal base
plate
6GT2801-1AB10
base plate turned
through 90°
6GT2801-1AB10-0AX1
6GT2801-1AB20-0AX1
6GT2801-1BA10
6GT2801-2AB10
SIMATIC RF300
System Manual, 07/2016, C79000-G8976-C345-0x
423
Appendix
A.4 Ordering data
Reader
Description
RF340R
second generation
•
With RS-422 interface (3964R)
•
IP67
•
Operating temperature -25 °C ... +70 °C
RF350R
•
Dimensions (L x W x H): 75 x 75 x 41 mm
•
with integrated antenna
•
ISO 15693 compatible
•
With RS-422 interface (3964R)
Article number
6GT2801-2BA10
6GT2801-4AB10
•
IP65
•
Operating temperature: -25 °C ... +70 °C
•
Dimensions (L x W x H): 75 x 75 x 41 mm
•
Reader for external antennas, with the option of connecting
ANT 1, ANT 3, ANT 12, ANT 18, ANT 30
RF350R
second generation
•
ISO 15693 compatible
•
With RS422 interface (3964R)
•
IP65
•
Operating temperature: -25 °C ... +70 °C
•
Dimensions (L x W x H): 75 x 75 x 41 mm
•
Reader for external antennas, with the option of connecting
6GT2801-4BA10
ANT 1, ANT 3, ANT 12, ANT 18, ANT 30
RF380R
RF380R
Scanmode
•
ISO 15693 compatible
•
with RS-422 interface (3964R) and RS-232 interface (3964R)
•
IP67
•
Operating temperature: -25 °C ... +70 °C
•
Dimensions (L x W x H): 160 x 80 x 41 mm
•
with integrated antenna
•
ISO 15693 compatible
•
with RS-422 interface (Scanmode) and RS-232 interface
(Scanmode)
•
IP67
•
Operating temperature: -25 °C ... +70 °C
•
Dimensions (L x W x H): 160 x 80 x 41 mm
•
with integrated antenna
•
ISO 15693 compatible
6GT2801-3AB10
6GT2801-3AB20-0AX1
SIMATIC RF300
424
System Manual, 07/2016, C79000-G8976-C345-0x
Appendix
A.4 Ordering data
Reader
Description
RF382R
(Scanmode)
•
with RS-422 interface (Scanmode) and RS-232 interface
(Scanmode)
•
IP67
•
Operating temperature: -25 °C ... +70 °C
RF350M
RF350M
•
Dimensions (L x W x H): 160 x 80 x 41 mm
•
with integrated antenna
•
ISO 15693 compatible
•
IP54
•
Operating temperature: -20 °C ... +55 °C
•
Dimensions (L x W x H): 250 x 90 x 47 mm
•
Mobile reader with integrated antenna
•
IP54
•
Operating temperature: -20 °C ... +55 °C
•
Dimensions (L x W x H): 250 x 90 x 47 mm
•
Mobile reader for external antennas, with the option of connecting
Article number
6GT2801-3AB20-0AX0
6GT2803-1BA00
6GT2803-1BA10
ANT 8, ANT 12, ANT 18, ANT 30
Table A- 10
RF300 transponder
RF300 transponder
Description
RF320T
•
IP67
•
Memory size: 20 bytes of EEPROM user memory
•
Operating temperature: -25 °C ... +85 °C
•
Dimensions (Ø x H): 27 x 4 mm
•
IP68
•
Memory size: 32 KB FRAM user memory
•
Operating temperature: -25 °C ... +85 °C
•
Dimensions (Ø x H): 30 x 8 mm
•
IP68
•
Memory size: 8 KB FRAM user memory
•
Operating temperature: -25 °C ... +85 °C
•
Dimensions (L x W x H): 48 x 25 x 15 mm
•
IP68
RF330T
RF340T
(8 KB FRAM)
RF340T
(32 KB FRAM)
•
Memory size: 32 KB FRAM user memory
•
Operating temperature: -25 °C ... +85 °C
•
Dimensions (L x W x H): 48 x 25 x 15 mm
Article number
6GT2800-1CA00
6GT2800-5BA00
6GT2800-4BB00
6GT2800-5BB00
SIMATIC RF300
System Manual, 07/2016, C79000-G8976-C345-0x
425
Appendix
A.4 Ordering data
RF300 transponder
Description
RF350T
•
IP68
•
Memory size: 32 KB FRAM user memory
•
Operating temperature: -25 °C ... +85 °C
•
Dimensions (L x W x H): 50 x 50 x 20 mm
•
IP67
•
Memory size: 8 KB FRAM user memory
•
Operating temperature: -25 °C ... +75 °C
•
Dimensions (L x W x H): 85.8 x 54.8 x 2.5 mm
•
IP67
•
Memory size: 32 KB FRAM user memory
•
Operating temperature: -25 °C ... +75 °C
•
Dimensions (L x W x H): 85.8 x 54.8 x 2.5 mm
•
IP68
•
Memory size: 32 KB FRAM user memory
•
Operating temperature: -25 °C ... +85 °C
•
Dimensions (L x W x H): 75 x 75 x 41 mm
•
IP68
RF360T
(8 KB FRAM)
RF360T
(32 KB FRAM)
RF370T
(32 KB FRAM)
RF370T
(64 KB FRAM)
RF380T
Table A- 11
MDS D117
6GT2800-4AC00
6GT2800-5AC00
6GT2800-5BE00
6GT2800-6BE00
•
Memory size: 64 KB FRAM user memory
•
Operating temperature: -25 °C ... +85 °C
•
Dimensions (L x W x H): 75 x 75 x 41 mm
•
IP68
•
Memory size 32 KB FRAM user memory
•
Operating temperature: -25 °C ... +200 °C (cyclic)
•
Dimensions (Ø x H): 114 x 83 mm
6GT2800-5DA00
ISO transponder
ISO transponder
MDS D100
Article number
6GT2800-5BD00
Description
Article number
6GT2600-0AD10
•
IP68
•
Memory size: 112 bytes of EEPROM user memory
•
Operating temperature: -25 °C ... +80 °C
•
Dimensions (L x W x H): 85.6 x 54 x 0.9 mm
•
Credit card format
•
IP68
•
Memory size: 112 bytes of EEPROM user memory
•
Operating temperature: -25 °C ... +85 °C
•
Dimensions (Ø x H): 4 x 5 mm
6GT2600-0AG00
SIMATIC RF300
426
System Manual, 07/2016, C79000-G8976-C345-0x
Appendix
A.4 Ordering data
ISO transponder
Description
MDS D124
•
IP67; IPx9K
•
Memory size: 112 bytes of EEPROM user memory
•
Operating temperature: -25 °C ... +180 °C
•
Dimensions (Ø x H): 27 (±0.2) x 4 (±0.2) mm
•
IP68
•
Memory size: 112 bytes of EEPROM user memory
•
Operating temperature: -25 °C ... +85 °C
•
Dimensions (Ø x H): 50 x 3.6 mm
•
Round design with mounting hole
•
IP68; IPx9K
•
Memory size: 112 bytes of EEPROM user memory
•
Operating temperature: -25 °C ... +125 °C
•
Dimensions (Ø x H): M6 x 5.8 (±0.2) mm
•
IP68; IPx9K
•
Memory size: 112 bytes of EEPROM user memory
•
Operating temperature: up to +200 °C/+220 °C
•
Dimensions (Ø x H): 85 (±0.5) x 15 (-1.0) mm
•
IP68; IPx9K
•
Memory size: 112 bytes of EEPROM user memory
•
Operating temperature: -25 °C...+70 °C
•
Dimensions (Ø x H): 16 (±0.2) x 3.0 (±0.2) mm
•
Laundry transponder for cyclic applications
•
IP65
•
Memory size: 112 bytes of EEPROM user memory
•
Operating temperature: -25 °C ... +85 °C
•
Dimensions (L x W): 86 x 54 mm
•
Smartlabel (PET) in credit card format
•
IP67
•
Memory size: 256 bytes of EEPROM user memory
•
Operating temperature: -20 °C ... +60 °C
•
Dimensions (L x W x H): 86 x 54 x 0.8 mm
•
Credit card format
•
IP65
•
Memory size: 256 bytes of EEPROM user memory
•
Operating temperature: -25 °C ... +85 °C
•
Dimensions (L x W): 55 x 55 mm
•
Smartlabel (PET), small design
MDS D126
MDS D127
MDS D139
MDS D160
MDS D165
MDS D200
MDS D261
Article number
6GT2600-0AC10
6GT2600-0AE00
6GT2600-0AF00
6GT2600-0AA10
6GT2600-0AB10
6GT2600-1AB00-0AX0
6GT2600-1AD00-0AX0
6GT2600-1AA00-0AX0
SIMATIC RF300
System Manual, 07/2016, C79000-G8976-C345-0x
427
Appendix
A.4 Ordering data
ISO transponder
Description
MDS D324
•
IP67; IPx9K
•
Memory size: 992 bytes of EEPROM user memory
•
Operating temperature: -25 °C...+125 °C
•
Dimensions (Ø x H): 27 (±0.2) x 4 (±0.2) mm
•
IP68; IPx9K
•
Memory size: 992 bytes of EEPROM user memory
•
Operating temperature: -25 °C ... +220 °C
•
Dimensions (Ø x H): 85 (±0.5) x 15 (-1.0) mm
•
IP67
•
Memory size: 2000 bytes of FRAM user memory
•
Operating temperature: -25 °C ... +60 °C
•
Dimensions (L x W x H) 85.6 (±0.3) × 54 (±0.2) × 0.8 (±0.05) mm
•
IP67; IPx9K
•
Memory size: 2000 bytes of FRAM user memory
•
Operating temperature –25 °C ... +85 °C
•
Dimensions (Ø x H): 10 x 4.5 mm
•
IP68
MDS D339
MDS D400
MDS D421
MDS D422
MDS D423
MDS D424
MDS D425
•
Memory size: 2000 bytes of FRAM user memory
•
Operating temperature: -25 °C ... +85 °C
•
Dimensions (Ø x H): M20 x 6 (±0.2) mm
•
Can be screwed into metal (flush-mounted)
•
IP68; IPx9K
•
Memory size: 2000 bytes of FRAM user memory
•
Operating temperature: -25 °C ... +85 °C
•
Dimensions (Ø x H): 30 (+0.2/-0.5) x 8 (-0.5) mm
•
IP67; IPx9K
•
Memory size: 2000 bytes of FRAM user memory
•
Operating temperature: -25 °C ... +125 °C
•
Dimensions (Ø x H): 27 (±0.2) x 4 (±0.2) mm
•
IP68; IPx9K
•
Memory size: 2000 bytes of FRAM user memory
•
Operating temperature: -25 °C ... +85 °C
•
Dimensions (Ø x H): 24 X 10 mm; M6 thread
•
Screw transponder
Article number
6GT2600-3AC00
6GT2600-3AA10
6GT2600-4AD00
6GT2600-4AE00
6GT2600-4AF00
6GT2600-4AA00
6GT2600-4AC00
6GT2600-4AG00
SIMATIC RF300
428
System Manual, 07/2016, C79000-G8976-C345-0x
Appendix
A.4 Ordering data
ISO transponder
Description
MDS D426
•
IP68
•
Memory size: 2000 bytes of FRAM user memory
•
Operating temperature: -25 °C ... +85 °C
•
Dimensions (Ø x H): 50 x 3.6 mm
•
Round design with mounting hole
•
IP68; IPx9K
•
Memory size: 2000 bytes of FRAM user memory
•
Operating temperature: -25 °C...+85 °C
•
Dimensions (Ø x H): 18(±1) x 20(±1) mm (without thread); thread
M8
•
IP68; IPx9K
MDS D428
MDS D460
MDS D521
MDS D522
MDS D522
Special variant
MDS D524
MDS D525
•
Memory size: 2000 bytes of FRAM user memory
•
Operating temperature: -25 °C...+85 °C
•
Dimensions (Ø x H): 16 (±0.2) x 3.0 (±0.2) mm
•
IP67; IPx9K
•
Memory size: 8192 bytes of FRAM user memory
•
Operating temperature –25 °C ... +85 °C
•
Dimensions (Ø x H): 10 x 4.5 mm
•
IP68
•
Memory size: 8192 bytes of FRAM user memory
•
Operating temperature: -25 °C ... +85 °C
•
Dimensions (Ø x H): M20 x 6 (±0.2) mm
•
Can be screwed into metal (flush-mounted)
•
IP68
•
Memory size: 8192 bytes of FRAM user memory
•
Operating temperature: -25 °C ... +85 °C
•
Dimensions (Ø x H): 18 (+0.1) x 5.2 mm
•
Can be clipped into metal (flush-mounted)
•
IP67
•
Memory size: 8192 bytes of FRAM user memory
•
Operating temperature: -25 °C ... +85 °C
•
Dimensions (Ø x H): 27 (±0.2) x 4 (±0.2) mm
•
IP67; IPx9K
•
Memory size: 8192 bytes of FRAM user memory
•
Operating temperature: -25 °C ... +85 °C
•
Dimensions (Ø x H): 24 x 10 (+1.0) mm
Article number
6GT2600-4AH00
6GT2600-4AK00-0AX0
6GT2600-4AB00
6GT2600-5AE00
6GT2600-5AF00
6GT2600-5AF00-0AX0
6GT2600-5AC00
6GT2600-5AG00
SIMATIC RF300
System Manual, 07/2016, C79000-G8976-C345-0x
429
Appendix
A.4 Ordering data
ISO transponder
Description
MDS D526
•
IP67; IPx9K
•
Memory size: 8192 bytes of FRAM user memory
•
Operating temperature: -25 °C ... +85 °C
•
Dimensions (Ø x H): 50 x 3.6 mm
•
Round design with mounting hole
•
IP68; IPx9K
•
Memory size: 8192 bytes of FRAM user memory
•
Operating temperature: -25 °C ... +85 °C
•
Dimensions (Ø x H): 18(±1) x 20(±1) mm (without thread); thread
M8
MDS D528
Table A- 12
Article number
6GT2600-5AH00
6GT2600-5AK00
Communication modules/interface modules
Communications module
Description
Article number
ASM 456
ASM 456 for PROFIBUS DP-V1
max. 2 readers connectable
6GT2002-0ED00
ASM 475
ASM 475 for SIMATIC S7
max. 2 RF3xxR readers with RS-422 can be connected in parallel without a front connector
6GT2002-0GA10
RF120C
Communications module RF120C for SIMATIC S7-1200
6GT2002-0LA00
RF160C
Communications module RF160C for PROFIBUS DP V0
max. 2 readers connectable
6GT2002-0EF00
RF170C
RF170C communications module
6GT2002-0HD00
RF170C connecting block
6GT2002-1HD00
RF180C communications module
max. 2 SLGs or readers can be connected
6GT2002-0JD00
Connecting block M12, 7/8'' (5-pin)
6GT2002-1JD00
Connecting block M12, 7/8'' (4-pin)
6GT2002-4JD00
Push-pull connecting block, RJ-45
6GT2002-2JD00
RF182C communications module
6GT2002-0JD10
RF180C
RF182C
max. 2 SLGs or readers can be connected
RFID 181EIP
Connecting block M12, 7/8'' (5-pin)
6GT2002-1JD00
Connecting block M12, 7/8'' (4-pin)
6GT2002-4JD00
Push-pull connecting block, RJ-45
6GT2002-2JD00
RF182C communications module
max. 2 SLGs or readers can be connected
6GT2002-0JD20
Connecting block M12, 7/8'' (5-pin)
6GT2002-1JD00
Connecting block M12, 7/8'' (4-pin)
6GT2002-4JD00
Push-pull connecting block, RJ-45
6GT2002-2JD00
SIMATIC RF300
430
System Manual, 07/2016, C79000-G8976-C345-0x
Appendix
A.4 Ordering data
Table A- 13
Antennas
Antenna
Description
ANT 1
•
IP67
ANT 3
ANT 3S
ANT 8
ANT 12
ANT 18
ANT 30
•
Operating temperature: -25 °C ... +70 °C
•
Dimensions (L x W x H): 75 x 75 x 20 mm
•
incl. an integrated antenna cable 3 m
•
IP67
Article number
6GT2398-1CB00
6GT2398-1CD30-0AX0
•
Operating temperature: -25 °C ... +70 °C
•
Dimensions (L x W x H): 50 x 28 x 10 mm
•
without antenna connecting cable
•
incl. one plug-in antenna connecting cable 3 m
6GT2398-1CD40-0AX0
•
IP67
6GT2398-1CD50-0AX0
•
Operating temperature: -25 °C ... +70 °C
•
Dimensions (L x W x H): 50 x 28 x 10 mm
•
without antenna connecting cable
•
incl. one plug-in antenna connecting cable 3 m
6GT2398-1CD60-0AX0
•
IP67
6GT2398-1CF00
•
Operating temperature: -25 °C ... +70 °C
•
Dimensions (Ø x L): M8 x 40 mm
•
without antenna connecting cable
•
incl. one plug-in antenna connecting cable 3 m
6GT2398-1CF10
•
IP67
6GT2398-1CC00
•
Operating temperature: -25 °C ... +70 °C
•
Dimensions (Ø x L): M12 x 40 mm
•
incl. one plug-in antenna connecting cable 3 m
•
IP67 (front)
•
Operating temperature: -25 °C ... +70 °C
•
Dimensions (Ø x L): M18 x 55 mm
•
incl. one plug-in antenna connecting cable 3 m
•
IP67
•
Operating temperature: -25 °C ... +70 °C
•
Dimensions (Ø x L): M30 x 58 mm
•
incl. one plug-in antenna connecting cable 3 m
6GT2398-1CA00
6GT2398-1CD00
SIMATIC RF300
System Manual, 07/2016, C79000-G8976-C345-0x
431
Appendix
A.4 Ordering data
Accessories
Table A- 14
Accessories for RF300 reader
Reader
Accessories
Article number
RF380R
RS-232 plug-in cable with 4-pin connector
6GT2891-4KH50
Plug-in cable RS-232 with open ends (5 m)
6GT2891-4KH50-0AX0
Plug-in cable with D-SUB ↔ M12, 8-pin
and with M8, 3-pin power unit connector
6GT2891-4KH50-0AX1
Table A- 15
RF300 transponder accessories
Transponder
Accessories
Article number
RF320T
Spacer (Ø x H): 36 x 22 mm
6GT2690-0AK00
RF330T
Fixing hood (L x W x H): 49.4 x 20 x 9.8 mm
6GT2690-0EA00
RF360T
Spacer (L x W x H): 110 x 62 x 24 mm
(in conjunction with fixing pocket 6GT2190-0AB00)
6GT2190-0AA00
Fixing pocket (L x W x H): 121 x 57 x 5 mm
(in conjunction with spacer 6GT2190-0AA00)
6GT2190-0AB00
Holder (short version)
6GT2090-0QA00
Holder (long version)
6GT2090-0QA00-0AX3
Shrouding cover
6GT2090-0QB00
Universal holder
6GT2590-0QA00
RF380T
Table A- 16
Transponder accessories
Transponder
Accessories
Article number
MDS D100 / D200 /
D400 / D600 / D611
Spacer
6GT2190-0AA00
Fixing pocket
6GT2190-0AB00
Securing pocket
(cannot be mounted directly on metal)
6GT2390-0AA00
Spacer (Ø x H): 85 x 30 mm
6GT2690-0AA00
Quick change holder (Ø x H): 22 x 60 mm
6GT2690-0AH00
Quick change holder (Ø x H): 22 x 47 mm
6GT2690-0AH10
MDS D124 / D324 /
D424 / D524
Spacer (Ø x H): 36 x 22 mm
6GT2690-0AK00
MDS D126 / D426 /
D526 / E624
Spacer (Ø x H): 59 x 30 mm
6GT2690-0AL00
MDS D160 / D460
Spacer (Ø x H): 20 x 14 mm
6GT2690-0AG00
MDS D423 / RF330T
Spacer (L x W x H): 49.4 x 20 x 9.8 mm
6GT2690-0EA00
MDS D139 / D339
SIMATIC RF300
432
System Manual, 07/2016, C79000-G8976-C345-0x
Appendix
A.4 Ordering data
Table A- 17
Accessory connecting RF300 reader ↔ PC
Connecting cable
Accessories
Article number
RF240R / RF260R /
RF290R (RS232)
Connecting cable RS-232
with M12 male connector (4-pin), 5 m
6GT2891-4KH50
and PC
Connecting cable RS-232
with open ends, 5 m
6GT2891-4KH50-0AX0
Table A- 18
Accessories - connecting cable communications module/ASM ↔ reader
Connecting cables
Description
Article number
Length
ASM 456 / RF160C /
RF170C / RF180C
2m
6GT2891-4FH20
and reader RF3xxR
(RS422)
5m
6GT2891-4FH50
10 m
6GT2891-4FN10
20 m
6GT2891-4FN20
50 m
6GT2891-4FN50
ASM 456 / RF160C /
RF170C / RF180C
2m
6GT2891-4JH20
and RF3xxR reader
(RS-422) with angled
connector
5m
6GT2891-4JH50
10 m
6GT2891-4JN10
ASM 475
2m
6GT2891-4EH20
and reader RF3xxR
(RS422)
5m
6GT2891-4EH50
RF120C
2m
6GT2091-4LH20
and reader RF3xxR
(RS422)
5m
6GT2091-4LH50
10 m
6GT2091-4LN10
Table A- 19
RFID accessories, general
RFID general
Article number
DVD "Ident Systems Software & Documentation"
6GT2080-2AA20
Wide-range power supply unit for SIMATIC RF systems
(100 - 240 VAC / 24 VDC / 3 A)
with country-specific power cable/plug, 2 m
EU: 6GT2898-0AC00
UK: 6GT2898-0AC10
US: 6GT2898-0AC20
24 V connecting cable, 5 m
6GT2491-1HH50
M12 connector, 4-pin for wide range power supply unit, pack of 3
6GK1907-0DB106AA3
SIMATIC RF300
System Manual, 07/2016, C79000-G8976-C345-0x
433
Appendix
A.5 Service & Support
A.5
Service & Support
Technical Support
You can reach technical support for all PD projects as follows:
● Phone: + 49 (0) 911 895 7222
● Fax: + 49 (0) 911 895 7223
● E-mail (mailto:support.automation@siemens.com)
● Internet: Web form for Support Request
(https://support.industry.siemens.com/My/ww/en/requests)
Contacts
If you have any further questions on the use of our products, please contact one of our
representatives at your local Siemens office.
The addresses are found on the following pages:
● On the Internet (http://w3.siemens.com/aspa_app)
● In Catalog CA 01
● In the catalog ID 10 specially for Industrial Identification Systems
Service & Support for Process Industries and Drives
On the Internet, on the Support home page (https://support.industry.siemens.com/cs/de/en/)
of Process Industries and Drives (PD), you will find various services.
There you will find the following information, for example:
● Our newsletter containing up-to-date information on your products.
● Relevant documentation for your application, which you can access via the search
function in "Product Support".
● A forum for global information exchange by users and specialists.
● Your local contact for PD.
● Information about on-site service, repairs, and spare parts. Much more can be found
under "Our service offer".
RFID homepage
For general information about our identification systems, visit RFID homepage
(http://w3.siemens.com/mcms/identification-systems/).
Online catalog and ordering system
The online catalog and the online ordering system can also be found on the Industry Mall
Homepage (https://mall.industry.siemens.com).
SIMATIC RF300
434
System Manual, 07/2016, C79000-G8976-C345-0x
Appendix
A.5 Service & Support
Training center
We offer appropriate courses to get you started. Please contact your local training center or
the central training center in
D-90327 Nuremberg.
Phone: +49 (0) 180 523 56 11
(€ 0.14 /min. from the German landline network, deviating mobile communications prices are
possible)
For information about courses, see the SITRAIN homepage
(http://sitrain.automation.siemens.com/sitrainworld/).
SIMATIC RF300
System Manual, 07/2016, C79000-G8976-C345-0x
435
Appendix
A.5 Service & Support
SIMATIC RF300
436
System Manual, 07/2016, C79000-G8976-C345-0x
Index
Antennas
Minimum clearances, 200
Application Planning
SIMATIC RF300, 37
Approvals, 405
ASM 475
Assignment for connecting cable, 386, 419
Cable installation, 387
Design and function, 382
Function of the LEDs, 385
Indicators, 385
Ordering data, 383
Pin assignment, 386, 419
Status display with LEDs, 385
Dwell time
Transponder, 46
Dynamic mode, 45
Dwell time of the transponder, 46
Electromagnetic compatibility
Coupling paths, 104
Electromagnetic interference, 102
EMC directives
Definition, 100
Equipotential bonding, 110
EMC Directives
Propagation of electromagnetic interference, 102
EMC Guidelines
Avoiding interference, 109
Basic Rules, 101
Cabinet configuration, 106
Cable shielding, 111
Overview, 99
Equipotential bonding, 110
Error codes
Reader, 395
Cabinet configuration, 106
Cable, 417
Reader - ASM, 417
Shielding, 111
Certificates, 405
Communication modules, 379
Communication time
Calculation, 47
Connecting cable
Reader-communication module/ASM/PC, 417
Contacts, 434
Coupling paths, 104
Courses, 435
Customer benefits, 31
FC 45, 397
Field data
ISO transponder, 52, 57
RF300 transponder, 49
Fields of application, 31
Flush-mounting
of transponders and readers, 63
Detection area, 44
Diagnostic functions
Transponder, 401
Direction of motion
Transponder, 44
Display elements
RF310R reader with RS-422 interface, 116
RF340R reader, 137
RF350R reader, 144, 167
High-performance, 22
Inductive alternating field, 37
Input parameter, 379
Installation
Several readers, 64
Installation guidelines, 62
SIMATIC RF300
System Manual, 07/2016, C79000-G8976-C345-0x
437
Index
Interface modules, 379
Interference sources
Electromagnetic, 103
ISO 14443 functionality, 114
ISO 15693 functionality, 113
ISO transponder
Resistance to chemicals, 90
Main applications, 31
MDS D100 transponder
Technical specifications, 256
MDS D117 transponder
Technical specifications, 260
MDS D124 Transponder
Technical specifications, 264
MDS D127 transponder
Technical specifications, 274
MDS D160 transponder
Technical specifications, 285
MDS D200 transponder
Technical specifications, 293
MDS D339 transponder
Technical specifications, 305
MDS D424 Transponder
Technical specifications, 332
MDS D425 Transponder
Technical specifications, 335
MDS D428 transponder
Technical specifications, 343
MDS D460 Transponder
Technical specifications, 347
MDS D521 transponder
Technical specifications, 353
MDS D522 transponder
Technical specifications, 356
MDS D524 transponder
Technical specifications, 365
MDS D525 transponder
Technical specifications, 368
MDS D526 transponder
Technical specifications, 373
MDS D528 transponder
Technical specifications, 376
MDS STATUS, 397
Medium-performance, 22
Memory configuration of the RF300 transponders, 208
Metal
Influence on the transmission window, 65
Metal-free area
Reader RF310R, 117, 124
Reader RF340R, 138
RF380R reader, 168, 177
Transponder RF330T, 216
Transponder RF340T, 221
Transponder RF350T, 224
Transponder RF360T, 229
Transponder RF370T, 235
Transponder RF380T, 242
Metal-free space
RF310R reader, 131
RF340R reader, 154
Minimum clearances
Antenna to antenna, 200
Minimum distance
Antenna to antenna, 61
Reader to reader, 60
Transponder to transponder, 59
Ordering data, 423
Antennas, 196, 431
Communications modules, 430
ISO transponder, 426
Overview, 423
Reader, 423
RF300 transponder, 425
RF310R Scanmode, 122
RF310R with RS-422 interface, 115, 129
RF340R with RS-422 interface, 136, 152
RF350R with RS-422 interface, 143, 159
RF380R Scanmode, 175
RF380R with RS-422 interface, 166
RF382R Scanmode, 182
Parameterization
Function blocks, 379
Possible combinations
Reader - transponder, 24, 27, 30
Read/write distance, 37
Reader
Installing, 64
Reader RF310R
Metal-free area, 117, 124
Reader RF340R
Metal-free area, 138
SIMATIC RF300
438
System Manual, 07/2016, C79000-G8976-C345-0x
Index
Reducing interference due to metal, 62
Reduction of field data by metal
RF310R, 65
RF340R, 69
RF350R with ANT 1, 73
RF350R with ANT 18, 80
RF350R with ANT 3, 76
RF350R with ANT 30, 83
RF380R, 85
RF382R, 89
Resistance to chemicals
Transponder, 90
RF300 system diagnostics
SLG STATUS, 398
RF300 transponder
Resistance to chemicals, 90
RF310R reader, 115, 122, 129
Characteristics, 115, 122, 129
Metal-free space, 131
RF330T
Characteristics, 215
RF340R reader, 136, 152
Characteristics, 136, 152
Metal-free space, 154
RF350R reader, 143, 159
Characteristics, 143, 159
RF380R reader, 166
Characteristics, 166
Metal-free area, 168, 177
RF380R Scanmode reader, 175
Characteristics, 175
RFID systems
Overview, 21
Scanmode, 22
Selection criteria
SIMATIC RF300 components, 37
Shielding, 111
SLG STATUS, 397
Static mode, 45
Dwell time of the transponder, 46
Structure
System manual, 13
System diagnostics
MDS status, 401
System overview
RFID systems, 21
Technical specifications
MDS D100 transponder, 256
MDS D117 transponder, 260
MDS D124 Transponder, 264
MDS D127 transponder, 274
MDS D160 transponder, 285
MDS D200 transponder, 293
MDS D339 transponder, 305
MDS D424 Transponder, 332
MDS D425 Transponder, 335
MDS D428 transponder, 343
MDS D460 Transponder, 347
MDS D521 transponder, 353
MDS D522 transponder, 356
MDS D524 transponder, 365
MDS D525 transponder, 368
MDS D526 transponder, 373
MDS D528 transponder, 376
Transponder MDS D126, 270
Transponder MDS D139, 279
Transponder MDS D165, 289
Transponder MDS D261, 297
Transponder MDS D324, 301
Transponder MDS D400, 312
Transponder MDS D421, 318
Transponder MDS D422, 323
Transponder MDS D423, 327
Transponder MDS D426, 340
Transponder RF320T, 213
Transponder RF330T, 217
Transponder RF340T, 222
Transponder RF350T, 227
Transponder RF360T, 232
Transponder RF370T, 236
Transponder RF380T, 247
Technical Support, 434
Tracking
Tolerance, 40
Tracking tolerances, 40
Training, 435
Transmission gaps, 48
Transmission window
Antennas, 39
Impact of metal, 65
Reader, 38
Width, 40
Transponder
Detection area, 44
Directions of motion, 44
Dwell time, 46
Mounting on metal, 64
SIMATIC RF300
System Manual, 07/2016, C79000-G8976-C345-0x
439
Index
Transponder MDS D126
Technical specifications, 270
Transponder MDS D139
Technical specifications, 279
Transponder MDS D165
Technical specifications, 289
Transponder MDS D261
Technical specifications, 297
Transponder MDS D324
Technical specifications, 301
Transponder MDS D400
Technical specifications, 312
Transponder MDS D421
Technical specifications, 318
Transponder MDS D422
Technical specifications, 323
Transponder MDS D423
Technical specifications, 327
Transponder MDS D426
Technical specifications, 340
Transponder RF320T
Characteristics, 211
Technical specifications, 213
Transponder RF330T
Characteristics, 215
Metal-free area, 216
Technical specifications, 217
Transponder RF340T
Characteristics, 220
Metal-free area, 221
Technical specifications, 222
Transponder RF350T
Characteristics, 224
Metal-free area, 224
Technical specifications, 227
Transponder RF360T
Characteristics, 229
Metal-free area, 229
Technical specifications, 232
Transponder RF370T
Characteristics, 234
Metal-free area, 235
Technical specifications, 236
Transponder RF380T
Metal-free area, 242
Technical specifications, 247
User data
Calculation, 47
SIMATIC RF300
440
System Manual, 07/2016, C79000-G8976-C345-0x

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : SIEMENS AG
Create Date                     : 2016:07:12 09:45:24+02:00
Keywords                        : Draft, Document!, Note:, This, document, is, a, draft, document., This, document, is, not, released, for, publication., Siemens, accepts, no, liability, for, the, completeness, and, correctness, of, the, contents.
Modify Date                     : 2016:08:01 12:00:28+02:00
Has XFA                         : No
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Metadata Date                   : 2016:08:01 12:00:28+02:00
Creator Tool                    : Acrobat PDFMaker 11 für Word
Document ID                     : uuid:b70fa864-d883-4fd1-bf2f-f4a77846d359
Instance ID                     : uuid:2c2c93d2-fe0d-4e38-97e7-2b479d040162
Format                          : application/pdf
Title                           : SIMATIC RF300
Description                     : SIMATIC Ident
Creator                         : SIEMENS AG
Subject                         : Draft Document!, Note: This document is a draft document. This document is not released for publication. Siemens accepts no liability for the completeness and correctness of the contents.
Producer                        : Adobe PDF Library 11.0
Source Modified                 : D:20160712074354
Company                         : Siemens AG
Comments                        : 
Edition                         : 0.00347222222222222
System                          : SIMATIC Ident
Print-year                      : 2005 - 2016
Document-class                  : System Manual
Document-class-mrl              : 
Product-group                   : RFID systems
Order-nr                        : C79000-G8976-C345-0x
Ident-nr                        : 
Company-short                   : Siemens
Company-long                    : Siemens AG
Headline                        : System Manual
Page Layout                     : OneColumn
Page Mode                       : UseOutlines
Page Count                      : 36
EXIF Metadata provided by EXIF.tools
FCC ID Filing: NXW-RF340R02

Navigation menu