Siemens RF340R02 RFID Reader 13.56 MHz User Manual SIMATIC RF300
Siemens AG RFID Reader 13.56 MHz SIMATIC RF300
Siemens >
Contents
User Manual part 2
Antennas 6.1 Features For the RF350R and RF350M readers, you can use the following plug-in antennas: Antenna Product photo ANT 1 Limit distance Sg 1) Dimensions Up to 140 mm 75 x 75 x 20 mm (L x W x H) ANT 3 Up to 50 mm 50 x 75 x 10 mm (L x W x H) SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 193 Antennas 6.1 Features Antenna Product photo ANT 3S Limit distance Sg 1) Dimensions Up to 5 mm 50 × 28 × 10 mm (L x W x H) ANT 8 2) Up to 4 mm M8 x 1.0 x 39 mm (∅ x thread x L) ANT 12 Up to 16 mm M12 x 1.0 x 40 mm (∅ x thread x L) ANT 18 Up to 35 mm M18 x 1.0 x 55 mm (Ø x thread x L) ANT 30 Up to 55 mm M30 x 1.5 x 61 mm (Ø x thread x L) 1) Depending on the transponder used 2) only released with RF350M und RF350R - second generation SIMATIC RF300 194 System Manual, 07/2016, C79000-G8976-C345-0x Antennas 6.1 Features Note Use of the antennas in hazardous areas The antennas ANT 1, ANT 12, ANT 18 and ANT 30 are approved for use in hazardous locations. For more information, refer to the section "Use of the reader in hazardous areas (Page 149)". ANT 1 The ANT 1 is an antenna in the mid performance range and can be used to the customer's advantage in production and assembly lines due to its manageable housing shape. The antenna dimensions make it possible to read/write large quantities of data dynamically from/to the transponder during operation. The antenna cable can be connected at the reader end. ANT 3 The ANT 3 is designed for use in small assembly lines. The extremely compact design of the antenna allows extremely accurate positioning. The antenna cable can be connected at the reader end. ANT 3S The ANT 3S is designed for use in small assembly lines. The extremely compact design of the antenna allows extremely accurate positioning even with small transponders. The antenna cable can be connected at the reader end. ANT 8 The ANT 8 is primarily envisaged for tool identification applications. The extremely small design of the antenna allows extremely accurate positioning. The antenna cable can be connected at the reader end and screwed to the antenna. The antenna ANT 8 has currently only been tested and released for use in conjunction with the mobile reader RF350M and the reader RF350R - second generation. ANT 12 The ANT 12 is primarily envisaged for tool identification applications. The very small size of the antenna means that highly exact positioning is possible using the plastic nuts included in the scope of delivery. The antenna cable can be connected at the reader end. ANT 18 The ANT 18 is designed for use in small assembly lines. Due to its small, compact construction, the antenna can be easily positioned for any application using two plastic nuts (included in the package). The antenna cable can be connected at the reader end. SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 195 Antennas 6.2 Ordering data ANT 30 The ANT 30 is designed for use in small assembly lines. In comparison to ANT 18, the maximum write/read distance is approximately 60 % larger. Due to its compact construction, the antenna can be easily positioned for any application using two plastic nuts (included in the package). The antenna cable can be connected at the reader end. 6.2 Ordering data Table 6- 1 Ordering data for antennas Article number ANT 1 incl. integrated antenna cable 3 m 6GT2398-1CB00 ANT 3 without antenna connecting cable 6GT2398-1CD30-0AX0 incl. plug-in antenna cable 3 m 6GT2398-1CD40-0AX0 without antenna connecting cable 6GT2398-1CD50-0AX0 incl. plug-in antenna cable 3 m 6GT2398-1CD60-0AX0 without antenna connecting cable 6GT2398-1CF00 ANT 3S ANT 8 incl. plug-in antenna cable 3 m 6GT2398-1CF10 ANT 12 incl. plug-in antenna cable 3 m 6GT2398-1CC00 ANT 18 incl. plug-in antenna cable 3 m 6GT2398-1CA00 ANT 30 incl. plug-in antenna cable 3 m 6GT2398-1CD00 Table 6- 2 Antenna accessories ordering data Article number Antenna connecting cable 6.3 3m 6GT2398-0AH30 Ensuring reliable data exchange The "center point" of the transponder must be situated within the transmission window. SIMATIC RF300 196 System Manual, 07/2016, C79000-G8976-C345-0x Antennas 6.4 Metal-free area 6.4 Metal-free area The antennas ANT 1, ANT 8, ANT 12, ANT 18 and ANT 30 can be flush-mounted in metal. Please allow for a possible reduction in the field data values. During installation, maintain the minimum distances (a and b) on/flush with the metal. Note Reduction of range if the metal-free space is not maintained At values lower than a and b, the field data changes significantly, resulting in a reduction in the limit distance and operating distance. Therefore, during installation, maintain the minimum distances (a and b) on/flush with the metal. Metal-free space for flush-mounted installation of ANT 1 a= 40 mm Figure 6-1 ANT 1 flush-mounted in metal SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 197 Antennas 6.4 Metal-free area Metal-free space for flush-mounted installation of ANT 3 and ANT 3S ① ② ANT 3 = 10 mm Metal Figure 6-2 ANT 3 and ANT 3S flush-mounted in metal Flush-mounting of ANT 8 Figure 6-3 ANT 8 flush-mounted in metal The ANT 8 can be flush-mounted in metal. Flush-mounting of ANT 12 Figure 6-4 ANT 12 flush-mounted in metal The ANT 12 can be flush-mounted in metal. SIMATIC RF300 198 System Manual, 07/2016, C79000-G8976-C345-0x Antennas 6.4 Metal-free area Metal-free space for flush-mounted installation of ANT 18 a= 10 mm b= 10 mm Figure 6-5 ANT 18 flush-mounted in metal Metal-free space for flush-mounted installation of ANT 30 a= 20 mm b= 20 mm Figure 6-6 ANT 30 flush-mounted in metal SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 199 Antennas 6.5 Minimum distance between antennas 6.5 Table 6- 3 Minimum distance between antennas Minimum distance between antennas Diagram (example) Minimum distance [mm] Antennas next to each other ANT 1 D ≥ 100 mm ANT 3 D ≥ 80 mm ANT 3S D ≥ 20 mm ANT 8 D ≥ 50 mm ANT 12 D ≥ 70 mm ANT 18 D ≥ 100 mm ANT 30 D ≥ 100 mm Antennas face to face ANT 1 D ≥ 500 mm ANT 3 D ≥ 100 mm ANT 3S D ≥ 50 mm ANT 8 D ≥ 50 mm ANT 12 D ≥ 100 mm ANT 18 D ≥ 100 mm ANT 30 D ≥ 200 mm The reader electronics can be mounted directly alongside each other. SIMATIC RF300 200 System Manual, 07/2016, C79000-G8976-C345-0x Antennas 6.6 Technical specifications 6.6 Table 6- 4 Technical specifications Technical specifications of the antennas ANT 1, ANT 3 , ANT 3S and ANT 8 ANT 1 ANT 3 ANT 3S ANT 8 140 mm 50 mm 5 mm 4 mm 75 x 75 x 20 mm (L x W x H) 50 x 28 x 10 mm (L x W x H) 50 x 28 x 10 mm (L x W x H) M8 x 1.0 x 39 mm (Ø x thread x L) Anthracite Black Black silver-metallic Plastic PA 12 Plastic PA6-V0 Plastic PA6-V0 Stainless steel M8, 4-pin; (pins on antenna side) M8, 4-pin; socket on antenna side M8, 4-pin; socket on antenna side M8, 4-pin; (pins on antenna side) Max. write/read distance antenna ↔ transponder (Sg) Housing dimensions Color Material Plug connection Degree of protection to EN 60529 IP67 Shock-resistant acc. to EN 60721-3-7, Class 7M2 50 g 1) Vibration-resistant to EN 60721-3-7, Class 7M2 20 g (3 to 50 Hz) 1) Attachment of the antenna 2 x M5 screws IP67 (front) 2 x M4 screws 2 x M4 screws 2x stainless steel nuts M8 x 1.0 mm Ambient temperature • During operation • -25 ℃ ... +70 ℃ • During transportation and storage • -40 °C ... +85 °C Weight, approx. • without antenna cable • -- • 35 g • 35 g • 10 g • with antenna cable (3.0 m) • 225 g • 160 g • 160 g • 140 g 1) Warning: The values for shock and vibration are maximum values and must not be applied continuously. SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 201 Antennas 6.6 Technical specifications Table 6- 5 Technical specifications of the antennas ANT 12, ANT 18 and ANT 30 ANT 12 ANT 18 ANT 30 16 mm 35 mm 55 mm M12 x 1.0 x 40 mm (Ø x thread x L) M18 x 1.0 x 55 mm (Ø x thread x L) M30 x 1.5 x 61 mm (Ø x thread x L) Max. write/read distance antenna ↔ transponder (Sg) Housing dimensions Color Pale turquoise Material Plastic Crastin Plug connection M8, 4-pin; (pins on antenna side) Degree of protection to EN 60529 IP67 (front) Shock-resistant acc. to EN 60721-3-7, Class 7M2 50 g 1) Vibration-resistant to EN 60721-3-7, Class 7M2 20 g (3 to 50 Hz) 1) Attachment of the antenna 2 plastic nuts M12 x 1.0 mm 2 plastic nuts M18 x 1.0 mm 2 plastic nuts M30 x 1.5 mm Ambient temperature • During operation • -25 ℃ to +70 ℃ • During transportation and storage • -40 ℃ to +85 ℃ Approx. weight • without antenna cable • -- • -- • -- • with antenna cable (3.0 m) • 145 g • 130 g • 180 g 1) Warning: The values for shock and vibration are maximum values and must not be applied continuously. SIMATIC RF300 202 System Manual, 07/2016, C79000-G8976-C345-0x Antennas 6.7 Dimensional drawings 6.7 Dimensional drawings The cable length is 3 m. All dimensions are in mm. ANT 1 Figure 6-7 Dimension drawing for ANT 1 Figure 6-8 Dimension drawing ANT 3 7 ANT 3S ANT 3 / ANT 3S SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 203 Antennas 6.7 Dimensional drawings ANT 8 Figure 6-9 Dimension drawing for ANT 8 Figure 6-10 Dimension drawing for ANT 12 Figure 6-11 Dimension drawing for ANT 18 ANT 12 ANT 18 SIMATIC RF300 204 System Manual, 07/2016, C79000-G8976-C345-0x Antennas 6.7 Dimensional drawings ANT 30 Figure 6-12 Dimension drawing for ANT 30 SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 205 Antennas 6.7 Dimensional drawings SIMATIC RF300 206 System Manual, 07/2016, C79000-G8976-C345-0x RF300 transponder Features of the RF300 transponders The RF300 transponders (RF3xxT) stand out particularly for their extremely fast data exchange with the RF300 readers (RF3xxR). With the exception of the RF320T transponder, all of the RF300 transponders have 8 to 64 KB of FRAM memory, which has an almost unlimited capacity for reading and writing. SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 207 RF300 transponder 7.1 Memory configuration of the RF300 transponders 7.1 1) Memory configuration of the RF300 transponders Physically identical memory When the OTP area is used, the corresponding user area (FF00-FF13) can no longer be modified (read only). Figure 7-1 Memory configuration of the RF300 transponders SIMATIC RF300 208 System Manual, 07/2016, C79000-G8976-C345-0x RF300 transponder 7.1 Memory configuration of the RF300 transponders EEPROM area The memory configuration of an RF300 transponder always comprises an EEPROM that has 20 bytes for user data (read/write) and a 4-byte unique serial number (UID, read only). For reasons of standardization, the UID is transferred as an 8 byte value through a read command to address FFF0 with a length of 8. The unused 4 high bytes are filled with zeros. Note Write speed The EEPROM user memory (address FF00-FF13, or FF80-FF90) requires significantly more time for writing (approx. 11 ms/byte) than the high-speed FRAM memory. For time-critical applications with write functions, it is advisable to use FRAM transponders (e.g. RF330T, RF340T, RF350T, RF360T, RF370T, RF380T). FRAM area Depending on the tag type, high-speed FRAM memory is available. (8 KB, 32 KB, 64 KB). This area does not exist for the RF320T. In the case of RF3xxT transponders with FRAM memory, the data carrier initialization command (INIT) is only effective on this memory area but not on the EEPROM area (FF00FF13). OTP area The EEPROM memory area (address FF00-FF13) can also be used as a so-called "OTP" memory (One Time Programmable). The 5 block addresses FF80, FF84, FF88, FF8C and FF90 are used for this purpose. A write command to this block address with a valid length (4, 8, 12, 16, 20 depending on the block address) protects the written data from subsequent overwriting. Note Seamless use of the OTP area When the OTP area is used, it must be ensured that the blocks are used starting from Block 0 consecutively. Examples: • 3 blocks (with write command), Block 0, 1, 2 (FF80, length = 12): valid • 2 blocks (consecutive), Block 0 (FF80, length =4), Block 1 (FF84, length = 4): valid • 2 blocks (consecutive), Block 0 (FF80, length =4), Block 2 (FF88, length = 4): Invalid • 1 Block, Block 4 (FF90, length = 4): Invalid SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 209 RF300 transponder 7.1 Memory configuration of the RF300 transponders Note Use of the OTP area is not reversible If you use the OPT area, you cannot undo it, because the OPT area can only be written to once. SIMATIC RF300 210 System Manual, 07/2016, C79000-G8976-C345-0x RF300 transponder 7.2 SIMATIC RF320T 7.2 SIMATIC RF320T 7.2.1 Features RF320T 7.2.2 Characteristics Area of application Identification tasks on small assembly lines in harsh industrial environments Memory size 20 bytes of EEPROM user memory Write/read range See section Field data of RF300 transponders (Page 49) Mounting on metal Yes, with spacer Degree of protection IP67/IPx9K Ordering data Table 7- 1 Ordering data RF320T Article number RF320T Table 7- 2 6GT2800-1CA00 Ordering data for RF320T accessories Article number Spacer 6GT2690-0AK00 SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 211 RF300 transponder 7.2 SIMATIC RF320T 7.2.3 Mounting on metal Mounting on metal ≥ 15 mm Figure 7-2 Mounting the MDS D124/D324/D424/D524/E624 and RF320T on metal with spacer Flush-mounting ≥ 15 mm ≥ 25 mm Figure 7-3 Flush-mounting of the MDS D124/D324/D424/D524/E624 and RF320T in metal with spacer SIMATIC RF300 212 System Manual, 07/2016, C79000-G8976-C345-0x RF300 transponder 7.2 SIMATIC RF320T Note Going below the distances If the distances (a and h) are not observed, a reduction of the field data results. It is possible to mount the MDS with metal screws (M3 countersunk head screws). This has no tangible impact on the range. 7.2.4 Technical data Table 7- 3 Technical specifications for RF320T 6GT2800-1CA00 Product type designation SIMATIC RF320T Memory Memory organization Byte-oriented, write protection possible in 4-byte blocks Memory configuration • UID • 4 bytes EEPROM • User memory • 20 bytes EEPROM • OPT memory • 20 bytes EEPROM Read cycles (at < 40 ℃) > 1014 Write cycles (at < 40 ℃) > 105 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data of RF300 transponders (Page 49)" MTBF (Mean Time Between Failures) 1800 years Mechanical specifications Housing • Material • Epoxy resin • Color • Black Recommended distance to metal ≥ 20 mm Power supply Inductive, without battery SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 213 RF300 transponder 7.2 SIMATIC RF320T 6GT2800-1CA00 Permitted ambient conditions Ambient temperature • During operation • -25 to +125 ℃ • During transportation and storage • -40 to +140 ℃ • IP67 • IPx9K Degree of protection to EN 60529 Shock-resistant to EN 60721-3-7, Class 7 M3 100 g 1) Vibration-resistant to EN 60721-3-7, Class 7 M3 20 g 1) Torsion and bending load Not permitted Design, dimensions and weight 7.2.5 Dimensions (Ø x H) 27 x 4 mm Weight 5g Type of mounting • 1 x M3 screw 2) ≤ 1.0 Nm • Glued 1) The values for shock and vibration are maximum values and must not be applied continuously. ) To prevent it loosening during operation, secure the screw with screw locking varnish. Dimension drawing Figure 7-4 RF320T dimension drawing Dimensions in mm SIMATIC RF300 214 System Manual, 07/2016, C79000-G8976-C345-0x RF300 transponder 7.3 SIMATIC RF330T 7.3 SIMATIC RF330T 7.3.1 Features Table 7- 4 RF330T 7.3.2 Characteristics Area of application In production automation for identification of metallic workpiece holders, workpieces or containers. Memory size 32 KB EEPROM user memory Write/read range See section "Field data of RF300 transponders (Page 49)" Mounting on metal Yes flush mounted on/in metal Degree of protection IP68/IPx9K Ordering data Table 7- 5 Ordering data RF330T Article number RF330T Table 7- 6 6GT2800-5BA00 Ordering data for RF330T accessories Article number Fixing hood RF330T / MDS D423 6GT2690-0EA00 SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 215 RF300 transponder 7.3 SIMATIC RF330T 7.3.3 Mounting on/in metal Direct mounting of the RF330T on metal is permitted. Mounting of the RF330T on metal Figure 7-5 Mounting of the RF330T on metal Flush-mounting of RF330T in metal ≥ 10 mm Figure 7-6 Mounting of the RF330T in metal with 10 mm clearance SIMATIC RF300 216 System Manual, 07/2016, C79000-G8976-C345-0x RF300 transponder 7.3 SIMATIC RF330T Figure 7-7 Mounting of the RF330T in metal without clearance Note Reduction of the write/read range Note that when the device is flush-mounted in metal without a surrounding clearance ≥ 10 mm, the write/read range is significantly reduced. 7.3.4 Technical specifications Table 7- 7 RF330T technical specifications 6GT2800-5BA00 Product type designation SIMATIC RF330T Memory Memory organization in bytes Memory configuration • UID • 4 bytes EEPROM • User memory • 8 KB FRAM • OPT memory • 20 bytes EEPROM Read cycles (at < 40 ℃) > 1014 Write cycles (at < 40 ℃) > 1014 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data of RF300 transponders (Page 49)" MTBF (Mean Time Between Failures) 1200 years SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 217 RF300 transponder 7.3 SIMATIC RF330T 6GT2800-5BA00 Mechanical specifications Housing • Material • Plastic PPS • Color • Black Recommended distance to metal ≥ 0 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • During operation • -25 to +85 ℃ • During transportation and storage • -40 to +100 ℃ • IP68 2 hours, 2 m, 20 ℃ • IPx9K steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75 °C • Low pressure resistant vacuum dryer: up to 20 mbar • high pressure resistant (see degree of protection IPx9K) Degree of protection to EN 60529 Pressure resistance Shock-resistant to EN 60721-3-7, Class 7 M3 50 g 1) Vibration-resistant to EN 60721-3-7, Class 7 M3 20 g 1) Torsion and bending load Not permitted Design, dimensions and weight Dimensions (Ø x H) 30 x 8 mm Weight 10 g Type of mounting 1 x M4 screw 2) ≤ 1.5 Nm 1) The values for shock and vibration are maximum values and must not be applied continuously. ) To prevent it loosening during operation, secure the screw with screw locking varnish. SIMATIC RF300 218 System Manual, 07/2016, C79000-G8976-C345-0x RF300 transponder 7.3 SIMATIC RF330T 7.3.5 Dimension drawing Figure 7-8 RF330T dimension drawing Dimensions in mm SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 219 RF300 transponder 7.4 SIMATIC RF340T 7.4 SIMATIC RF340T 7.4.1 Features Table 7- 8 RF340T 7.4.2 Characteristics Area of application Identification tasks on small assembly lines in harsh industrial environments Memory size • 8 KB FRAM user memory • 32 KB FRAM user memory Write/read range See section Field data of RF300 transponders (Page 49) Mounting on metal Yes Degree of protection IP68/IPx9K Ordering data Table 7- 9 Ordering data RF340T Article number RF340T 8 KB FRAM user memory 6GT2800-4BB00 RF340T 32 KB FRAM user memory 6GT2800-5BB00 SIMATIC RF300 220 System Manual, 07/2016, C79000-G8976-C345-0x RF300 transponder 7.4 SIMATIC RF340T 7.4.3 Mounting on metal Direct mounting of the RF340T on metal is permitted. Mounting of RF340T on metal Figure 7-9 Mounting of RF340T on metal Flush-mounting of RF340T in metal: Figure 7-10 Flush-mounting of RF340T in metal The standard value for a is ≥ 20 mm. At lower values, the field data change significantly, resulting in a reduction in the range. SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 221 RF300 transponder 7.4 SIMATIC RF340T 7.4.4 Technical specifications Table 7- 10 Technical specifications for RF340T 6GT2800-4BB00 Product type designation SIMATIC RF340T Memory Memory organization in bytes Memory configuration • UID • 4 bytes EEPROM • User memory • 8 KB FRAM • OPT memory • 20 bytes EEPROM Read cycles (at < 40 ℃) > 1010 Write cycles (at < 40 ℃) > 1010 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data of RF300 transponders (Page 49)" MTBF (Mean Time Between Failures) 1200 years Mechanical specifications Housing • Material • Plastic PA 12 • Color • Anthracite Recommended distance to metal ≥ 0 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • During operation • -25 to +85 ℃ • During transportation and storage • -40 to +85 ℃ • IP68 • IPx9K Degree of protection to EN 60529 Shock-resistant to EN 60721-3-7, Class 7 M3 50 g 1) Vibration-resistant to EN 60721-3-7, Class 7 M3 20 g 1) Torsion and bending load Not permitted SIMATIC RF300 222 System Manual, 07/2016, C79000-G8976-C345-0x RF300 transponder 7.4 SIMATIC RF340T 6GT2800-4BB00 Design, dimensions and weight Dimensions (L x W x H) 48 x 25 x 15 mm Weight 25 g Type of mounting 2 x M3 screws ≤ 1.0 Nm 1) 7.4.5 The values for shock and vibration are maximum values and must not be applied continuously. Dimension drawing Figure 7-11 RF340T dimension drawing Dimensions in mm SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 223 RF300 transponder 7.5 SIMATIC RF350T 7.5 SIMATIC RF350T 7.5.1 Features RF350T 7.5.2 Characteristics Area of application Identification tasks on small assembly lines in harsh industrial environments Memory size 32 KB FRAM user memory Write/read range See section Field data of RF300 transponders (Page 49) Mounting on metal Yes Degree of protection IP68 Ordering data Table 7- 11 Ordering data RF350T Article number 7.5.3 6GT2800-5BD00 • IP68 • Memory size: 32 KB FRAM (read/write) and 4 bytes EEPROM (read only) • Operating temperature: -25 °C to +85 °C • Dimensions: 50 x 50 x 20 (L x W x H, in mm) • incl. securing frame Mounting on metal Direct mounting of the RF350T on metal is permitted. SIMATIC RF300 224 System Manual, 07/2016, C79000-G8976-C345-0x RF300 transponder 7.5 SIMATIC RF350T Mounting of RF350T on metal Figure 7-12 Mounting of RF350T on metal Flush-mounting of RF350T in metal: Figure 7-13 RF350T flush-mounted in metal The standard value for a is ≥ 20 mm. At lower values, the field data change significantly, resulting in a reduction in the range. SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 225 RF300 transponder 7.5 SIMATIC RF350T 7.5.4 Mounting options Mounting with fixing frame The RF350T transponder can be mounted as shown with the fixing frame: Figure 7-14 Installation diagram Dimensions of the fixing frame Figure 7-15 RF350T fixing frame SIMATIC RF300 226 System Manual, 07/2016, C79000-G8976-C345-0x RF300 transponder 7.5 SIMATIC RF350T 7.5.5 Technical data Table 7- 12 Technical specifications for RF350T 6GT2800-5BD00 Product type designation SIMATIC RF350T Memory Memory organization in bytes Memory configuration • UID • 4 bytes EEPROM • User memory • 32 KB FRAM • OPT memory • 20 bytes EEPROM Read cycles (at < 40 ℃) > 1010 Write cycles (at < 40 ℃) > 1010 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data of RF300 transponders (Page 49)" MTBF (Mean Time Between Failures) 1200 years Mechanical specifications Housing • Material • Plastic PA 12 • Color • Anthracite Recommended distance to metal ≥ 0 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • During operation • -25 to +85 ℃ • During transportation and storage • -40 to +85 ℃ Degree of protection to EN 60529 IP68 Shock-resistant to EN 60721-3-7, Class 7 M3 50 g 1) Vibration-resistant to EN 60721-3-7, Class 7 M3 20 g 1) Torsion and bending load Not permitted SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 227 RF300 transponder 7.5 SIMATIC RF350T 6GT2800-5BD00 Design, dimensions and weight Dimensions (L x W x H) 50 x 50 x 20 mm Weight 25 g Type of mounting 2 x M4 screws ≤ 1.5 Nm 1) 7.5.6 The values for shock and vibration are maximum values and must not be applied continuously. Dimension drawing Figure 7-16 RF350T dimension drawing Dimensions in mm SIMATIC RF300 228 System Manual, 07/2016, C79000-G8976-C345-0x RF300 transponder 7.6 SIMATIC RF360T 7.6 SIMATIC RF360T 7.6.1 Features RF360T 7.6.2 Characteristics Area of application Identification tasks on small assembly lines in harsh industrial environments Memory size • 8 KB FRAM user memory • 32 KB FRAM user memory Write/read range see section Field data of RF300 transponders (Page 49) Mounting on metal Yes, with spacer Degree of protection IP67 Ordering data Table 7- 13 Ordering data RF360T Article number RF360T 8 KB FRAM user memory 6GT2800-4AC00 RF360T 32 KB FRAM user memory 6GT2800-5AC00 Table 7- 14 Ordering data for RF360T accessories Article number 7.6.3 Spacer (in conjunction with fixing pocket 6GT2190-0AB00) 6GT2190-0AA00 Fixing pocket (in conjunction with spacer 6GT2190-0AA00) 6GT2190-0AB00 Mounting on metal Direct mounting of the RF360T on metal is not allowed. A distance ≥ 20 mm is recommended. This can be achieved using the spacer 6GT2190-0AA00 in combination with the fixing pocket 6GT2190-0AB00. SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 229 RF300 transponder 7.6 SIMATIC RF360T Mounting of RF360T on metal Figure 7-17 Mounting of RF360T with spacer The standard value for h is ≥ 20 mm. Flush-mounting of RF360T in metal: Figure 7-18 Flush-mounting of RF360T with spacer The standard value for a is ≥ 20 mm. At lower values, the field data change significantly, resulting in a reduction in the range. SIMATIC RF300 230 System Manual, 07/2016, C79000-G8976-C345-0x RF300 transponder 7.6 SIMATIC RF360T Dimensions of spacer and fixing pocket for RF360T Figure 7-19 Dimensions of spacer and fixing pocket for RF360T SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 231 RF300 transponder 7.6 SIMATIC RF360T 7.6.4 Technical data Table 7- 15 Technical specifications for RF360T 6GT2800-4AC00 6GT2800-5AC00 Product type designation SIMATIC RF360T Memory Memory organization in bytes Memory configuration • UID • 4 bytes EEPROM • User memory • 8 KB FRAM • OPT memory • 20 bytes EEPROM Read cycles (at < 40 ℃) > 1010 Write cycles (at < 40 ℃) > 1010 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data of RF300 transponders (Page 49)" MTBF (Mean Time Between Failures) 1200 years Mechanical specifications Housing • Material • Epoxy resin • Color • Anthracite Recommended distance to metal ≥ 20 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • During operation • -25 to +75 ℃ • During transportation and storage • -40 to +85 ℃ Degree of protection to EN 60529 IP67 Shock-resistant to EN 60721-3-7, Class 7 M3 50 g Vibration-resistant to EN 60721-3-7, Class 7 M3 20 g Torsion and bending load Not permitted SIMATIC RF300 232 System Manual, 07/2016, C79000-G8976-C345-0x RF300 transponder 7.6 SIMATIC RF360T 6GT2800-4AC00 6GT2800-5AC00 Design, dimensions and weight 7.6.5 Dimensions (L x W x H) 86 x 55 x 2.5 mm Weight 25 g Type of mounting • 2 x M3 screws ≤ 1.0 Nm • Fixing pocket (6GT2190-0AB00) Dimension drawing Figure 7-20 RF360T dimension drawing Dimensions in mm SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 233 RF300 transponder 7.7 SIMATIC RF370T 7.7 SIMATIC RF370T 7.7.1 Features The SIMATIC RF370T transponder is a passive (i.e. battery-free) data carrier in a square type of construction. RF370T 7.7.2 Characteristics Area of application Identification tasks on assembly lines in harsh industrial environments, due to high resistance to oils, lubricants and cleaning agents, and suitable for larger ranges, e.g. automotive industry Memory size • 32 KB FRAM user memory • 64 KB FRAM user memory Write/read range see section Field data of RF300 transponders (Page 49) Mounting on metal Yes Degree of protection IP68/IPx9K Ordering data Table 7- 16 Ordering data RF370T Article number RF370T 32 KB FRAM user memory 6GT2800-5BE00 RF370T 76 KB FRAM user memory 6GT2800-6BE00 SIMATIC RF300 234 System Manual, 07/2016, C79000-G8976-C345-0x RF300 transponder 7.7 SIMATIC RF370T 7.7.3 Mounting on metal Direct mounting of the RF370T on metal is permitted. Mounting of RF370T on metal Figure 7-21 Mounting of RF370T on metal Flush-mounting of RF370T in metal: Figure 7-22 RF370T flush-mounted in metal The standard value for a is ≥ 20 mm. At lower values, the field data change significantly, resulting in a reduction in the range. SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 235 RF300 transponder 7.7 SIMATIC RF370T 7.7.4 Mounting instructions It is essential that you observe the instructions in the Section Installation guidelines (Page 62). 7.7.5 Properties Description Type of installation Screw fixing (two M5 screws) Tightening torque < 1.2 Nm (at room temperature) Technical specifications Table 7- 17 Technical specifications RF370T 6GT2800-5BE00 6GT2800-6BE00 Product type designation SIMATIC RF370T Memory Memory organization in bytes Memory configuration • UID • 4 bytes EEPROM • User memory • 32 or 64 KB FRAM • OPT memory • 20 bytes EEPROM Read cycles (at < 40 ℃) > 1010 Write cycles (at < 40 ℃) > 1010 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data of RF300 transponders (Page 49)" MTBF (Mean Time Between Failures) 1200 years Mechanical specifications Housing • Material • Plastic PA 12 • Color • Anthracite Recommended distance to metal ≥ 0 mm Power supply Inductive, without battery SIMATIC RF300 236 System Manual, 07/2016, C79000-G8976-C345-0x RF300 transponder 7.7 SIMATIC RF370T 6GT2800-5BE00 6GT2800-6BE00 Permitted ambient conditions Ambient temperature • During operation • -25 to +85 ℃ • During transportation and storage • -40 to +85 ℃ Degree of protection to EN 60529 IPx9K Shock-resistant to EN 60721-3-7, Class 7 M3 50 g 1) Vibration-resistant to EN 60721-3-7, Class 7 M3 20 g 1) Torsion and bending load Not permitted Design, dimensions and weight Dimensions (L x W x H) 75 x 75 x 41 mm Weight 200 g Type of mounting 2 x M5 screws ≤ 1.5 Nm 1) 7.7.6 The values for shock and vibration are maximum values and must not be applied continuously. Dimensional drawing Figure 7-23 RF370T dimension drawing SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 237 RF300 transponder 7.8 SIMATIC RF380T Dimensions in mm 7.8 SIMATIC RF380T 7.8.1 Features The SIMATIC RF380T transponder is an extremely rugged and heat-resistant round data carrier suitable e.g. for applications in the automotive industry. SIMATIC RF380T transponder Characteristics Area of application Identification tasks in applications (e.g. automotive industry) with cyclic high temperature stress > 85 °C and < 220 °C Highly resistant to mineral oils, lubricants and cleaning agents Typical applications: 7.8.2 • Primer coat, electrolytic dip area, cataphoresis with the associated drying furnaces • Top coat area with drying furnaces • Washing areas at temperatures > 85°C • Other applications with higher temperatures Memory size 32 KB FRAM user memory Write/read range see section "Field data of RF300 transponders (Page 49)" Mounting on metal Yes, flush-mounted in metal Degree of protection IP68 Ordering data Table 7- 18 Ordering data RF380T Article number RF380T User memory 32 KB FRAM (read/write) and 4 bytes EEPROM Table 7- 19 6GT2800-5DA00 Ordering data for RF380T Article number Holder (short version) 6GT2090-0QA00 Holder (long version) 6GT2090-0QA00-0AX3 Shrouding cover 6GT2090-0QB00 Universal holder 6GT2590-0QA00 SIMATIC RF300 238 System Manual, 07/2016, C79000-G8976-C345-0x RF300 transponder 7.8 SIMATIC RF380T 7.8.3 Installation guidelines for RF380T It is essential that you observe the instructions in the Section Installation guidelines (Page 62). The following section only deals with features specific to the SIMATIC RF380T. 7.8.3.1 Mounting instructions Note Only use tag with original holder You are strongly recommended to only use the tag with the original holder specified. Only this holder guarantees that the data memory observes the listed values for shock, vibration and temperature. A protective cover is recommendable for applications in paint shops. Data memory holder Short version (6GT2 090-0QA00) Long version (6GT2090-0QA00-0AX3) Material: V2A sheet-steel with thickness 2.5 mm BI 2.5 DIN 59382 1.4541 SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 239 RF300 transponder 7.8 SIMATIC RF380T Assembly of data memory with holder Figure 7-24 Assembly of tag with holder Scope of supply The holder is provided with all mounting parts and a mounting diagram. Mounting screws for securing the holder are not included. The mounting screws are of diameter M 10. The minimum length is 25 mm. The optional cover can be used for the long and short versions of the holder. SIMATIC RF300 240 System Manual, 07/2016, C79000-G8976-C345-0x RF300 transponder 7.8 SIMATIC RF380T Universal holder Figure 7-25 Universal holder 6GT2590-0QA00 SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 241 RF300 transponder 7.8 SIMATIC RF380T 7.8.3.2 Metal-free area Direct mounting of the RF380T on metal is permitted. Mounting of RF380T on metal Figure 7-26 Mounting of RF380T on metal Flush-mounting of RF380T in metal: Figure 7-27 RF380T flush-mounted in metal The standard value for a is ≥ 40 mm. At lower values, the field data change significantly, resulting in a reduction in the range. SIMATIC RF300 242 System Manual, 07/2016, C79000-G8976-C345-0x RF300 transponder 7.8 SIMATIC RF380T 7.8.4 Configuring instructions 7.8.4.1 Temperature dependence of the transmission window The guidelines in the section "Planning the RF300 system" apply to configuration of heatresistant data memories, with the exception of the limit distance and field length at temperatures above 85 °C. At temperatures above 85 °C, the length of the transmission window is reduced by up to 10%. 7.8.4.2 Temperature response in cyclic operation At ambient temperatures (Tu) up to 110 °C, cyclic operation is not necessary, i.e. up to this temperature, the transponder can be in constant operation. Note Calculation of the temperature curves Calculation of the temperature curves or of a temperature profile can be carried out on request by Siemens AG. Exact knowledge of the internal temperature facilitates configuration for time-critical applications. You can also carry out the calculation with the aid of the "SIMATIC RF Temperature Calculator" on the "Ident Systems Software & Documentation" DVD (refer to the section "DVD "Ident Systems Software & Documentation" (Page 416)"). Ambient temperatures > 110 °C Note Cancellation of warranty The internal temperature of the data memory must not exceed the critical threshold of 110 °C. Each heating phase must be followed by a cooling phase. No warranty claims will otherwise be accepted. Some limit cycles are listed in the table below: Table 7- 20 Limit cycles of data memory temperature Tu (heating up) Heating up Tu (cooling down) Cooling down 220 °C 0.5 h 25 °C >2h 200 °C 1h 25 °C >2h 190 °C 1h 25 °C > 1 h 45 min 180 °C 2h 25 °C >5h 170 °C 2h 25 °C >4h SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 243 RF300 transponder 7.8 SIMATIC RF380T The internal temperature of the tag follows an exponential function with which the internal temperature and the operability of the tag can be calculated in advance. This is particularly relevant to temperature-critical applications or those with a complex temperature profile. Ambient temperatures > 220°C Note Cancellation of warranty The data memory must not be exposed to ambient temperatures > 220 °C. No warranty claims will otherwise be accepted. However, the mechanical stability is retained up to 230 °C! Example of a cyclic sequence Table 7- 21 Typical temperature profile of an application in the paint shop Start of tag at initial point Duration (min) Ambient temperature (°C) Electrolytic dip 20 30 Electrolytic dip dryer 60 200 Transport 60 25 PVC dryer 25 170 Transport 60 25 Filler dryer 60 160 Transport 60 25 Top coat dryer 60 120 Transport 60 25 Wax dryer 25 100 Transport 150 25 SIMATIC RF300 244 System Manual, 07/2016, C79000-G8976-C345-0x RF300 transponder 7.8 SIMATIC RF380T Figure 7-28 Graphic trend of temperature profile from above table The simulation results in the following: Following a simulation time of 36.5 hours, a total of 3 cycles were carried out, and an internal temperature of 90 degrees Celsius was reached. Figure 7-29 Complete temperature response due to simulation SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 245 RF300 transponder 7.8 SIMATIC RF380T 7.8.5 Use of the transponder in the Ex protection area The TÜV SÜD Automotive GmbH as approved test center as well as the TÜV SÜD Product Service GmbH as certification center, identification number 0123, as per Article 9 of the Directive of the European Council of 23 March 1994 (94/9/EC), has confirmed the compliance with the essential health and safety requirements relating to the design and construction of equipment and protective systems intended for use in hazardous areas as per Annex II of the Directive. The essential health and safety requirements are satisfied in accordance with the following standards: Table 7- 22 Approvals Document Title EN 60079-0: 2006 Electrical equipment for hazardous gas atmospheres Part 0: General requirements EN 60079-15: 2005 Electrical equipment for hazardous gas atmospheres Part 15: Design, testing and identification of electrical equipment with type of protection "n" DIN VDE 0848-5: 2001 (in parts) Safety in electrical, magnetic and electromagnetic fields Part 5: Explosion protection ZLS SK 107.1 Central office of the states for safety; test components Identification Table 7- 23 The identification of the electrical equipment as an encapsulated unit II 3G Ex nC IIB T5 -25°C to +70°C Um=30Vdc The equipment is assigned the following references: XXXYYYZZZ [= serial number, is assigned during production] TPS 09 ATEX 1 459 X [= certificate number] "No use of the equipment in the vicinity of processes generating high charges" 7.8.5.1 Use of the transponder in hazardous areas for gases Temperature class delineation for gases The temperature class of the transponder for hazardous areas depends on the ambient temperature range: Ambient temperature range Temperature class -25 °C to +70 °C T5 SIMATIC RF300 246 System Manual, 07/2016, C79000-G8976-C345-0x RF300 transponder 7.8 SIMATIC RF380T WARNING Ignitions of gas-air mixtures • When using the RF380T transponder, check that the temperature class is kept to in conjunction with the requirements of the area of application. If the temperature ranges are exceeded during use of the transponder, gas-air mixtures may be ignited. • The maximum transmit power of the transmitter used to operate the transponder must not exceed 2 W. If the transmit power id not kept to, gas-air mixtures may ignite. 7.8.5.2 Installation and operating conditions for the hazardous area a) Use of the equipment in the vicinity of processes generating high charges is not allowed. b) The equipment must be mechanically protected when installed. 7.8.6 Cleaning the mobile data memory Note Do not clean the transponder with mechanical tools, sand-blasting or pressure hose. These cleaning methods result in damage to the transponder. Clean the transponder only with the chemical cleansing agents listed in Chapter Chemical resistance of the transponders (Page 90). 7.8.7 Technical specifications Table 7- 24 RF380T technical specifications 6GT2800-5DA00 Product type designation SIMATIC RF380T Memory Memory organization in bytes Memory configuration • UID • 4 bytes EEPROM • User memory • 32 KB FRAM • OPT memory • 20 bytes EEPROM SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 247 RF300 transponder 7.8 SIMATIC RF380T 6GT2800-5DA00 Read cycles (at < 40 ℃) > 1010 Write cycles (at < 40 ℃) > 1010 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data of RF300 transponders (Page 49)" MTBF (Mean Time Between Failures) 1177 years Mechanical specifications Housing • Material • PPS • Color • Anthracite Recommended distance to metal ≥ 0 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • • During operation During transportation and storage • -25 to +110 ℃ • -25 … +220 ℃: cyclic operation possible • -40 to +110 ℃ Degree of protection to EN 60529 IP68 Shock-resistant to EN 60721-3-7, Class 7 M3 50 g 1)2) Vibration-resistant to EN 60721-3-7, Class 7 M3 5 g 2) Torsion and bending load Not permitted Design, dimensions and weight Dimensions (Ø x H) 114 x 83 mm Weight 900 g Type of mounting Holder (must be ordered separately) 1) Applies only in conjunction with the original support 2) The values for shock and vibration are maximum values and must not be applied continuously. SIMATIC RF300 248 System Manual, 07/2016, C79000-G8976-C345-0x RF300 transponder 7.8 SIMATIC RF380T 7.8.8 Dimensional drawing Figure 7-30 Dimension drawing RF380T Dimensions in mm SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 249 RF300 transponder 7.8 SIMATIC RF380T SIMATIC RF300 250 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder Features of the ISO transponders The transponders (MDS D) that are compatible with ISO 15693 represent a cost-effective alternative to RF300 transponders. The performance that can be achieved with this (transmission speed, memory size), however, is considerably less than with RF300 transponders. You will find more information on transmission speeds in the section "Communication between communications module, reader and transponder (Page 47)". SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 251 ISO transponder 8.1 Memory configuration of ISO the transponders 8.1 Memory configuration of ISO the transponders Figure 8-1 Memory configuration of ISO the transponders SIMATIC RF300 252 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.1 Memory configuration of ISO the transponders Memory areas Depending on the manufacturer of the transponder chip, the memory configuration of an ISO transponder consists of varying sizes of user memory. The typical sizes are 112 bytes, 256 bytes, 992 bytes EEPROM or 2000 bytes FRAM. Each ISO transponder chip has an 8-byte long unique serial number (UID, read only). This UID is transferred as an 8 byte value through a read command to address FFF0 with a length of 8. OTP area For the OTP area, a 16-byte address space is always reserved at the end of the memory area. The blocks are divided up depending on the chip (see technical specifications). Note that the corresponding addresses for the user data are therefore not available to the application when the OTP area is used. A total of 4 block addresses ("mapped" addresses) are provided: ● FF80 ● FF84 ● FF88 ● FF8C A write command to this block address with a valid length (4, 8, 12, 16 bytes depending on the block address) protects the written data from subsequent overwriting. Note Exception Fujitsu chip (MDS D4xx and MDS D522) The Fujitsu chip MB89R118 (MDS D4xx) has 8-byte blocks, which means that only 2 block addresses have to be addressed: FF80 and FF88 with the length 8 and 16 bytes). The Fujitsu chip MB89R112 (MDS D5xx) has 32 byte blocks and can therefore not be addressed in the OTP area. Note Restriction to the use of the OTP Observe the following restrictions when using OTP: • The OTP write/lock command can only be sent in static operation. • The OTP write/lock command can not be sent as a chained command. The Fujitsu chip MB89R112 (MDS D5xx) has 32 byte blocks and can therefore not be addressed in the OTP area. Note Use of the OTP area is not reversible If you use the OPT area, you cannot undo it, because the OPT area can only be written to once. SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 253 ISO transponder 8.2 MDS D100 8.2 MDS D100 8.2.1 Characteristics MDS D100 Characteristics Area of application 8.2.2 From simple identification such as electronic barcode replacement/supplementation, through warehouse and distribution logistics, right up to product identification. Memory size 112 bytes of EEPROM user memory Write/read range See section Field data of ISO transponders (MDS D) (Page 52). Mounting on metal Yes, with spacer ISO standard ISO 15693 Degree of protection IP68 Ordering data Table 8- 1 Ordering data for MDS D100 Article number MDS D100 Table 8- 2 6GT2600-0AD10 Ordering data for MDS D100 accessory Article number 8.2.3 Spacer (in conjunction with fixing pocket 6GT2190-0AB00) 6GT2190-0AA00 Fixing pocket (in conjunction with spacer 6GT2190-0AA00) 6GT2190-0AB00 Fixing pocket (not suitable for fixing directly onto metal) 6GT2390-0AA00 Metal-free area Direct mounting of the MDS D100 on metal is not allowed. A distance of ≥ 20 mm is recommended. This can be achieved using the spacer 6GT2190-0AA00 in combination with the fixing pocket 6GT2190-0AB00. SIMATIC RF300 254 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.2 MDS D100 Mounting on metal ① ② ③ ≥ 20 mm Data memory Metal Non-metal Figure 8-2 Mounting of the MDS D100 on metal with spacer SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 255 ISO transponder 8.2 MDS D100 Flush-mounting ≥ 20 mm ≥ 20 mm ① ② ③ Data memory Metal Non-metal Figure 8-3 Flush-mounting of MDS D100 in metal with spacer Note If the minimum guide values (h or a) are not observed, a reduction of the field data results. 8.2.4 Technical data Table 8- 3 Technical specifications for MDS D100 6GT2600-0AD10 Product type designation SIMATIC MDS D100 Memory Memory configuration • UID • 8 bytes • User memory • 112 bytes EEPROM • OPT memory • 16 bytes (EEPROM) SIMATIC RF300 256 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.2 MDS D100 6GT2600-0AD10 Read cycles (at < 40 ℃) > 1014 Write cycles (at < 40 ℃) > 106 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data of ISO transponders (MDS D) (Page 52)" MTBF (Mean Time Between Failures) 228 years Mechanical specifications Housing • Material • PC • Color • White/petrol Recommended distance to metal ≥ 20 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • During operation • -25 to +80 ℃ • During transportation and storage • -25 to +80 ℃ Degree of protection to EN 60529 • IP68 Shock-resistant to EN 60721-3-7 class 7M3 ISO 10373 / ISO 7810 1) Vibration-resistant to EN 60721-3-7, class 7M3 ISO 10373 / ISO 7810 1) Torsion and bending load ISO 10373/ISO 7816-1 Design, dimensions and weight Dimensions (L x W x H) 85.6 x 54 x 0.9 mm Weight 5g Type of mounting • Fixing pocket • Glued 1) The values for shock and vibration are maximum values and must not be applied continuously. SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 257 ISO transponder 8.2 MDS D100 8.2.5 Dimension drawing Dimensions in mm 1) Dimensions for mounting holes Figure 8-4 MDS D100 dimension drawing SIMATIC RF300 258 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.3 MDS D117 8.3 MDS D117 8.3.1 Features MDS D117 8.3.2 Characteristics Area of application Very compact data carrier that can be cemented into objects where precise positioning is necessary; e.g. tool identification, workpiece holders etc.. Memory size 112 bytes of EEPROM user memory Write/read range See section "Field data of ISO transponders (MDS D) (Page 52)." Mounting in metal Yes, flush-mounted in metal ISO standard ISO 15693 Degree of protection IP68/IPx9K Ordering data Table 8- 4 Ordering data for MDS D117 Article number MDS D117 6GT2600-0AG00 Pack of 10 SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 259 ISO transponder 8.3 MDS D117 8.3.3 Mounting in metal Flush-mounted in metal ① Transponder ② Metal 8.3.4 Technical specifications Table 8- 5 Technical specifications for MDS D117 6GT2600-0AG00 Product type designation SIMATIC MDS D117 Memory Memory configuration • UID • 8 bytes • User memory • 112 bytes EEPROM • OPT memory • 16 bytes (EEPROM) Read cycles (at < 40 ℃) > 1014 Write cycles (at < 40 ℃) > 106 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data of ISO transponders (MDS D) (Page 52)" MTBF (Mean Time Between Failures) 228 years SIMATIC RF300 260 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.3 MDS D117 6GT2600-0AG00 Mechanical specifications Housing • Material • PPS • Color • Black Recommended distance to metal ≥ 0 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • During operation • -25 to +85 ℃ • During transportation and storage • -40 to +125 ℃ Degree of protection to EN 60529 IP68 2 hours, 2 bar, +20 °C Shock-resistant to EN 60721-3-7 class 7M3 100 g 1) Vibration-resistant to EN 60721-3-7, class 7M3 20 g 1) Torsion and bending load Not permitted Design, dimensions and weight Dimensions (Ø x H) 4 x 5.2 mm Weight 1g Type of mounting 1) 8.3.5 • Fixing pocket • Glued The values for shock and vibration are maximum values and must not be applied continuously. Dimension drawing Figure 8-5 Dimensions in mm SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 261 ISO transponder 8.4 MDS D124 8.4 MDS D124 8.4.1 Characteristics MDS D124 8.4.2 Characteristics Area of application Application areas in production automation (e.g. small paintshops up to +180 °C) Memory size 112 bytes of EEPROM user memory Write/read range See section "Field data of ISO transponders (MDS D) (Page 52)". Mounting on metal Yes, with spacer ISO standard ISO 15693 Degree of protection IP68/IPx9K Ordering data Table 8- 6 Ordering data for MDS D124 Article number MDS D124 Table 8- 7 6GT2600-0AC10 Ordering data for MDS D124 accessories Article number Spacer 6GT2690-0AK00 SIMATIC RF300 262 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.4 MDS D124 8.4.3 Mounting on metal Mounting on metal ≥ 15 mm Figure 8-6 Mounting the MDS D124/D324/D424/D524/E624 and RF320T on metal with spacer Flush-mounting ≥ 15 mm ≥ 25 mm Figure 8-7 Flush-mounting of the MDS D124/D324/D424/D524/E624 and RF320T in metal with spacer SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 263 ISO transponder 8.4 MDS D124 Note Going below the distances If the distances (a and h) are not observed, a reduction of the field data results. It is possible to mount the MDS with metal screws (M3 countersunk head screws). This has no tangible impact on the range. 8.4.4 Technical specifications Table 8- 8 Technical specifications for MDS D124 6GT2600-0AC10 Product type designation SIMATIC MDS D124 Memory Memory configuration • UID • 8 bytes • User memory • 112 bytes EEPROM • OPT memory • 16 bytes (EEPROM) Read cycles (at < 40 ℃) > 1014 Write cycles (at < 40 ℃) > 106 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data of ISO transponders (MDS D) (Page 52)" MTBF (Mean Time Between Failures) 228 years Mechanical specifications Housing • Material • PPS • Color • Black Recommended distance to metal ≥ 15 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • During operation • -25 to +180 ℃ • from +125 ℃: 20% reduction in the limit distance • from +140 ℃: No processing possible SIMATIC RF300 264 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.4 MDS D124 6GT2600-0AC10 • During transportation and storage Degree of protection to EN 60529 • at +180 ℃: Tested up to 5000 hours or 3000 cycles • -40 to +125 ℃ • IP68 2 hours, 2 bar, +20 °C • IPx9K steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75 °C Shock-resistant to EN 60721-3-7 class 7M3 100 g 1) Vibration-resistant to EN 60721-3-7, class 7M3 20 g 1) Torsion and bending load Not permitted Design, dimensions and weight 8.4.5 Dimensions (Ø x H) 4 x 5.2 mm Weight 5g Type of mounting • 1 x M3 screw 2) ≤ 1 Nm • Glued • With spacer 1) The values for shock and vibration are maximum values and must not be applied continuously. ) To prevent it loosening during operation, secure the screw with screw locking varnish. Use of the MDS D124 in hazardous area The mobile data memory MDS D124, device group II, category 1G or 1D may be installed and operated in zones 0, 1 and 2 or in the zones 20, 21 and 22. The following requirements of the 94/9/EC directive are met: ● EN 60079-0:2009 ● EN 60079-11:2007 ● EN 61241-11:2006 ● EN 60079-26:2007 When used in hazardous areas, the MDS D124 must not be operated with field strengths > 5 A / m to avoid impermissible heating. This is not the case with readers from the SIMATIC RF range (MOBY D, RF200 and RF300). SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 265 ISO transponder 8.4 MDS D124 Identification II 1 G Ex ia IIC T3 to T6 Ga or II 1 D Ex ia IIIC T80 °C to T180 °C Da TÜV 12 ATEX 084413 X The temperature class or the maximum surface temperature depends on the maximum ambient temperature. The relationship between temperature class (gas) or maximum surface temperature (dust) can be found in the following table. Table 8- 9 Ambient temperature Ambient temperature range Temperature class Max. surface temperature -25 ... +150 ℃ T3 T180 -25 ... +100 ℃ T4 T130 -25 ... +65 ℃ T5 T95 -25 ... +50 ℃ T6 T80 Note Safety markings for hazardous areas Since there is not enough space on the MDS D124 for the safety mark, this is supplied as a label with the device. This must be affixed immediately next to the MDS D124 so that the label clearly relates to the device. WARNING Gefahr durch elektrostatische Entladungen Potential electrostatic charging hazard Danger potentiel de charges électrostatiques SIMATIC RF300 266 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.4 MDS D124 Note Installation and operating conditions for hazardous areas: • Use of the device in the vicinity of processes generating high charges is not allowed. • The device must be installed so that it is mechanically protected. • For applications requiring devices of category 1, the device must be mounted on a grounded, conductive base. • It must only be cleaned with a damp cloth. • The device is suitable for use in atmospheres containing dust, however not for full immersion in dust. 8.4.6 Dimension drawing Figure 8-8 Dimension drawing of MDS D124 All dimensions in mm SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 267 ISO transponder 8.5 MDS D126 8.5 MDS D126 8.5.1 Characteristics MDS D126 8.5.2 Characteristics Area of application Compact and rugged ISO transponder; suitable for identification of transport units in production-related logistics; can also be deployed in harsh conditions Memory size 112 bytes of EEPROM user memory Write/read range See section Field data of ISO transponders (MDS D) (Page 52) Mounting on metal Yes, with spacer ISO standard ISO-15693 Degree of protection IP68 Ordering data Table 8- 10 Ordering data for MDS D126 Article number MDS D126 Table 8- 11 6GT2600-0AE00 Ordering data for MDS D126 accessories Article number Spacer 6GT2690-0AL00 SIMATIC RF300 268 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.5 MDS D126 8.5.3 Mounting on metal Mounting on metal ≥ 25 mm Figure 8-9 Mounting the MDS D126 / D426 / D526 on metal with spacer Flush-mounted in metal ≥ 25 mm ≥ 50 mm Figure 8-10 Flush installation of the MDS D126 / D426 / D526 in metal with spacer SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 269 ISO transponder 8.5 MDS D126 8.5.4 Technical specifications Table 8- 12 Technical specifications for the MDS D126 6GT2600-0AE00 Product type designation SIMATIC MDS D126 Memory Memory configuration • UID • 8 bytes • User memory • 112 bytes EEPROM • OPT memory • 16 bytes (EEPROM) Read cycles (at < 40 ℃) > 1014 Write cycles (at < 40 ℃) > 106 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data of ISO transponders (MDS D) (Page 52)" MTBF (Mean Time Between Failures) 228 years Mechanical specifications Housing • Material • PA6.6 GF • Color • Black Recommended distance to metal ≥ 25 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • During operation • -25 to +85 ℃ • During transportation and storage • -40 to +100 ℃ Degree of protection to EN 60529 IP68 2 hours, 2 bar, +20 °C Shock-resistant to EN 60721-3-7 class 7M3 50 g 1) Vibration-resistant to EN 60721-3-7, class 7M3 20 g 1) Torsion and bending load Not permitted SIMATIC RF300 270 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.5 MDS D126 6GT2600-0AE00 Design, dimensions and weight 8.5.5 Dimensions (Ø x H) 50 x 3.6 mm Weight 13 g Type of mounting • 1 x M4 screw 2) ≤ 1 Nm • Glued 1) The values for shock and vibration are maximum values and must not be applied continuously. ) To prevent it loosening during operation, secure the screw with screw locking varnish. Dimension drawing Dimensions in mm Figure 8-11 Dimension drawing of MDS D126 SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 271 ISO transponder 8.6 MDS D127 8.6 MDS D127 8.6.1 Features MDS D127 8.6.2 Characteristics Area of application Very compact data carrier that can be screwed into areas where precise positioning is necessary; e.g. tool identification, workpiece holders etc. Memory size 112 bytes of EEPROM user memory Write/read range See section "Field data of ISO transponders (MDS D) (Page 52)" Mounting on metal Yes, flush-mounted in metal ISO standard ISO 15693 Degree of protection IP68/IPx9K Ordering data Table 8- 13 Ordering data for MDS D127 Article number MDS D127 6GT2600-0AF00 Pack of 10 (A screw-in aid is supplied with each pack) SIMATIC RF300 272 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.6 MDS D127 8.6.3 Mounting in metal Flush-mounted in metal ① Metal ② Transponders Note Damage to the transponder due to improper mounting To screw the MDS D127 into a suitable thread, use the supplied screw-in tool. This avoids damage to the MDS D127. Figure 8-12 Screw-in aid for mounting the MDS D127 SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 273 ISO transponder 8.6 MDS D127 8.6.4 Technical specifications Table 8- 14 Technical specifications for MDS D127 6GT2600-0AF00 Product type designation SIMATIC MDS D127 Memory Memory configuration • UID • 8 bytes • User memory • 112 bytes EEPROM • OPT memory • 16 bytes (EEPROM) Read cycles (at < 40 ℃) > 1014 Write cycles (at < 40 ℃) > 106 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data of ISO transponders (MDS D) (Page 52)" MTBF (Mean Time Between Failures) 228 years Mechanical specifications Housing • Material • PA6 • Color • Black Recommended distance to metal ≥ 0 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • During operation • -25 to +100 ℃ • During transportation and storage • -40 to +125 ℃ • IP68 2 hours, 2 bar, +20 °C • IPx9K steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75 °C Degree of protection to EN 60529 Shock-resistant to EN 60721-3-7 class 7M3 100 g 1) Vibration-resistant to EN 60721-3-7, class 7M3 20 g 1) Torsion and bending load Not permitted SIMATIC RF300 274 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.6 MDS D127 6GT2600-0AF00 Design, dimensions and weight Dimensions (Ø x H) M6 x 5.8 mm Weight 1g Type of mounting • Glued • 1 x M3 screw 1) 8.6.5 The values for shock and vibration are maximum values and must not be applied continuously. Dimension drawing Figure 8-13 Dimensions in mm SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 275 ISO transponder 8.7 MDS D139 8.7 MDS D139 8.7.1 Characteristics MDS D139 Characteristics Area of application Applications in production logistics and in assembly lines subject to high temperatures (up to +220 °C) Typical application areas: • Paintshops and their preparatory treatments) • Primer coat, electrolytic dip area, cataphoresis with the associated drying furnaces • Top coat area with drying furnaces • Washing areas at temperatures > 85 °C • Other applications with higher temperatures Memory size 112 bytes of EEPROM user memory Write/read range See section Field data of ISO transponders (MDS D) (Page 52). Mounting on metal Yes, with spacer ISO standard ISO 15693 Degree of protection IP68/IPx9K Note Compatibility with SIMATIC RF300 depending on the article number The transponder MDS D139 with article number 6GT2600-0AA10 is compatible with the SIMATIC RF300 system. The transponder MDS D139 with article number 6GT2600-0AA00 is not compatible. SIMATIC RF300 276 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.7 MDS D139 8.7.2 Ordering data Table 8- 15 Ordering data for MDS D139 Article number MDS D139 Table 8- 16 6GT2600-0AA10 Ordering data for MDS D139 accessory Article number 8.7.3 Spacer 6GT2690-0AA00 Quick change holder (Ø x H): 22 x 60 mm 6GT2690-0AH00 Quick change holder (Ø x H): 22 x 47 mm 6GT2690-0AH10 Mounting on metal Direct mounting of the MDS D139/D339 on metal is not allowed. A distance of ≥ 30 mm is recommended. This can be achieved using spacers (see "Ordering data (Page 423)"). Mounting on metal ≥ 30 mm Figure 8-14 Mounting the MDS D139/D339 on metal with spacer SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 277 ISO transponder 8.7 MDS D139 Flush-mounting It is possible to mount the MDS D139/D339 in metal. With large antennas, for example ANT D5, this leads to a reduction of ranges. ≥ 30 mm ≥ 100 mm Figure 8-15 Flush-mounting of the MDS D139/D339 in metal with spacer Note Going below the distances If the distances (a and h) are not observed, a reduction of the field data results. It is possible to mount the MDS with metal screws (M5). This has no tangible impact on the range. It is recommended that a test is performed in critical applications. 8.7.4 Cleaning the mobile data memory Note Do not clean the transponder with mechanical tools, sand-blasting or pressure hose. These cleaning methods result in damage to the transponder. Clean the transponder only with the chemical cleansing agents listed in Chapter Chemical resistance of the transponders (Page 90). SIMATIC RF300 278 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.7 MDS D139 8.7.5 Technical specifications Table 8- 17 Technical specifications for MDS D139 6GT2600-0AA10 Product type designation SIMATIC MDS D139 Memory Memory configuration • UID • 8 bytes • User memory • 112 bytes EEPROM • OPT memory • 16 bytes (EEPROM) Read cycles (at < 40 ℃) > 1014 Write cycles (at < 40 ℃) > 106 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data of ISO transponders (MDS D) (Page 52)" MTBF (Mean Time Between Failures) 228 years Mechanical specifications Housing • Material • PPS • Color • Black Recommended distance to metal ≥ 30 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • • During operation During transportation and storage • -25 to +220 ℃ • from +125 ℃: 20% reduction in the limit distance • from +140 ℃: No processing possible • at +200 ℃: Tested up to 5000 hours or 6000 cycles • at +220 ℃: Tested up to 2000 hours or 2000 cycles • -40 to +100 ℃ SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 279 ISO transponder 8.7 MDS D139 6GT2600-0AA10 Degree of protection to EN 60529 • IP68 2 hours, 2 bar, +20 °C • IPx9K steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75 °C Shock-resistant to EN 60721-3-7 class 7M3 50 g 1) Vibration-resistant to EN 60721-3-7, class 7M3 20 g 1) Torsion and bending load Not permitted Design, dimensions and weight 8.7.6 Dimensions (Ø x H) 85 x 15 mm Weight 50 g Type of mounting 1 x M5 screw 2) 1.5 Nm The values for shock and vibration are maximum values and must not be applied continuously. 2) For mounting with the spacer (6GT2690-0AA00), use a stainless steel M5 screw to avoid damaging the MDS in high temperatures (expansion coefficient). Use of the MDS D139 in hazardous areas The MDS D139 mobile data memory is classed as a piece of simple, electrical equipment and can be operated in Protection Zone 2, Device Group II, Category 3G. The following requirements of the 94/9/EC directive are met: ● EN 60079-0:2006 ● EN 60079-15:2005 ● EN 61241-0:2006 ● EN 61241-1:2004 Identification II 3 G Ex nA II T2 II 3 D Ex tD A22 IP68 T 220°C KEMA 09 ATEX 0133 X Ta: -25 ... +220°C SIMATIC RF300 280 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.7 MDS D139 WARNING Gefahr durch elektrostatische Entladungen Potential electrostatic charging hazard Danger potentiel de charges électrostatiques Note Installations- und Betriebsbedingungen für den Ex-Schutzbereich: a) Der Einsatz des Gerätes in der Nähe von stark ladungserzeugenden Prozessen ist untersagt. b) Das Gerät ist mechanisch geschützt zu montieren. c) Die Montage muss auf einem geerdeten, leitenden Untergrund erfolgen. d) Die Reinigung darf nur mit feuchtem Tuch erfolgen. Installation and operating conditions for hazardous areas: a) Use of the equipment in the vicinity of processes generating high charges is not allowed. b) The equipment must be mechanically protected when installed. c) Installation must be performed on a grounded and conductive mounting surface. d) Cleaning only with a wet cloth Conditions d'installation et de mise en oeuvre pour la zone de protection Ex : a) L'utilisation de l'appareil près de processus générant de fortes charges est interdite. b) L'appareil doit être monté de manière à être protégé mécaniquement. c) Le montage doit être effectué sur un socle conducteur mis à la terre. d) Nettoyage uniquement avec un chiffon humide SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 281 ISO transponder 8.7 MDS D139 8.7.7 Dimension drawings Dimensional drawing of MDS D139 Figure 8-16 Dimensional drawing of MDS D139 Dimensions in mm SIMATIC RF300 282 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.8 MDS D160 8.8 MDS D160 8.8.1 Characteristics MDS D160 Characteristics Area of application Thanks to its rugged packaging, the MDS D160 is a transponder that can be used under extreme environmental conditions. It is washable, heat-resistant and resistant to all chemicals generally used in the laundry process. Typical applications are, for example: 8.8.2 • Rented work clothing • Hotel laundry • Surgical textiles • Hospital clothing • Dirt collection mats • Clothing for nursing homes/hostels Memory size 112 bytes of EEPROM user memory Write/read range See section Field data of ISO transponders (MDS D) (Page 52). Mounting on metal Yes, with spacer ISO standard ISO 15693 Degree of protection IP68/IPx9K Information for RF300 compatibility Note Compatibility with SIMATIC RF300 depending on MLFB number Only the MDS D160 with MLFB 6GT2600-0AB10 is compatible with SIMATIC RF300. 8.8.3 Ordering data Table 8- 18 Ordering data for MDS D160 Article number MDS D160 6GT2600-0AB10 SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 283 ISO transponder 8.8 MDS D160 Table 8- 19 Ordering data for MDS D160 accessories Article number Spacer 8.8.4 6GT2690-0AG00 Mounting on metal Mounting on metal ① ② ③ Transponder ≥ 10 mm Metal carrier Spacer Figure 8-17 Mounting the MDS D160 on metal with spacer Note Going below the minimum distance (h) If the minimum distance (h) is not observed, a reduction of the field data results. In critical applications, it is recommended that a test is performed. Flush-mounting Flush-mounting of the MDS D160 in metal is not permitted! SIMATIC RF300 284 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.8 MDS D160 8.8.5 Technical specifications Table 8- 20 Technical specifications for the MDS D160 6GT2600-0AB10 Product type designation SIMATIC MDS D160 Memory Memory configuration • UID • 8 bytes • User memory • 112 bytes EEPROM • OPT memory • 16 bytes (EEPROM) Read cycles (at < 40 ℃) > 1014 Write cycles (at < 40 ℃) > 106 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data of ISO transponders (MDS D) (Page 52)" MTBF (Mean Time Between Failures) 228 years Mechanical specifications Housing • Material • PPS • Color • beige Recommended distance to metal ≥ 10 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • In operation, during write/read access • -25 … +85 °C • In operation, outside write/read access • -40 … +175 °C • from +125 ℃: for 1000 hours, 20% reduction of the limit distance • from +140 ℃: No processing possible • at +175 ℃: 100 washing cycles tested • at +220 ℃: Tested once for up to 30 seconds • -25 to +100 ℃ • During transportation and storage SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 285 ISO transponder 8.8 MDS D160 6GT2600-0AB10 Mechanical strength • Isostatic pressure • 300 bar for 5 min • Axial pressure • 1000 N for 10 s • Radial pressure • 1000 N for 10 s Resistance to chemicals All chemicals normally used in the washing process MDS lifespan At least 100 wash cycles Degree of protection • IP68 24 hours, 2 bar, +20 °C • IPx9K Shock-resistant to IEC 68-2-27 40 g 1) 18 ms; 6 axes; 2000 repetitions/h Vibration-resistant to IEC 68-2-6 10 g 1) 10 to 2000 Hz; 3 axes; 2.5 h Torsion and bending load Not permitted Design, dimensions and weight Dimensions (Ø x H) 16 x 3 mm Weight 1.2 g Type of mounting • Patched • Sewn in • Glued The values for shock and vibration are maximum values and must not be applied continuously. Note Regeneration time between washing cycles The regeneration time for the MDS D160 between washing cycles must be at least 24 hours. SIMATIC RF300 286 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.8 MDS D160 8.8.6 Dimension drawings Dimensional drawing of MDS D160 Dimensions in mm Figure 8-18 Dimensional drawing of MDS D160 Dimensional drawing of spacer Dimensions in mm Figure 8-19 Dimensional drawing of spacer SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 287 ISO transponder 8.9 MDS D165 8.9 MDS D165 8.9.1 Features MDS D165 (special version) Characteristics Area of application The design of the transponder (self-adhesive label) permits a variety of designs, guaranteeing optimum dimensioning for the widest variety of applications. From simple identification such as electronic barcode replacement/supplementation, through warehouse and distribution logistics, right up to product identification. 8.9.2 Memory size 112 bytes of EEPROM user memory Write/read range See section Field data of ISO transponders (MDS D) (Page 52). Mounting on metal Yes, with spacer ISO standard ISO 15693 Degree of protection IP65 Ordering data Table 8- 21 Ordering data for MDS D165 Article number MDS D165 (special version ISO-CARD) 6GT2600-1AB00-0AX0 Type of delivery Minimum order quantity: 1250 units (5 rolls with 250 units each) SIMATIC RF300 288 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.9 MDS D165 8.9.3 Technical data Table 8- 22 Technical specifications for MDS D165 6GT2600-1AB00-0AX0 Product type designation SIMATIC MDS D165 Memory Memory configuration • UID • 8 bytes • User memory • 112 bytes EEPROM • OPT memory • 16 bytes (EEPROM) Read cycles (at < 40 ℃) > 1014 Write cycles (at < 40 ℃) > 106 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Depending on the reader used, see section "Field data of ISO transponders (MDS D) (Page 52)" MTBF (Mean Time Between Failures) 228 years Mechanical specifications Housing • • Material Color • Top • PET plastic (label material) • Inlay • PET plastic (carrier material) • Antenna • Aluminum • Bottom • Double-sided transfer adhesive on silicon paper • White Recommended distance to metal ≥ 25 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • In operation, during write/read access • -5 to +85 °C • In operation, outside write/read access • -25 to +85 ℃ • During transportation and storage • +15 to +30 ℃ Can be stored for 2 years, determined by the durability of the adhesive. Degree of protection IP65 SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 289 ISO transponder 8.9 MDS D165 6GT2600-1AB00-0AX0 Design, dimensions and weight 8.9.4 Dimensions (L x W x H) 86 x 54 x 0.3 mm Weight 1g Type of mounting Glued with self-adhesive label Dimension drawing Dimensions in mm Figure 8-20 Dimension drawing of MDS D165 SIMATIC RF300 290 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.10 MDS D200 8.10 MDS D200 8.10.1 Features MDS D200 8.10.2 Characteristics Area of application From simple identification such as electronic barcode replacement/supplementation, through warehouse and distribution logistics, right up to product identification. Memory size 256 bytes of EEPROM user memory Write/read range See section Field data of ISO transponders (MDS D) (Page 52). Mounting on metal Yes, with spacer ISO standard 15693 with Tag-it HFI technology Degree of protection IP67 Ordering data Table 8- 23 Ordering data for MDS D200 Article number MDS D200 (special version ISO-CARD) Table 8- 24 6GT2600-1AD00-0AX0 Ordering data for MDS D200 accessories Article number Spacer (in conjunction with fixing pocket 6GT2190-0AB00) 6GT2190-0AA00 Fixing pocket (in conjunction with spacer 6GT2190-0AA00) 6GT2190-0AB00 Fixing pocket (not suitable for fixing directly onto metal) 6GT2390-0AA00 SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 291 ISO transponder 8.10 MDS D200 8.10.3 Mounting on metal Mounting on metal ① ② ③ ≥ 20 mm Data memory Metal Non-metal Figure 8-21 Mounting of the MDS D200 on metal with spacer SIMATIC RF300 292 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.10 MDS D200 Flush-mounting ≥ 20 mm ≥ 20 mm ① ② ③ Data memory Metal Non-metal Figure 8-22 Flush-mounting of MDS D200 in metal with spacer Note If the minimum guide values (h) are not observed, a reduction of the field data results. 8.10.4 Technical data Table 8- 25 Technical specifications for MDS D200 6GT2600-1AD00-0AX0 Product type designation SIMATIC MDS D200 Memory Memory configuration • UID • 8 bytes • User memory • 256 bytes EEPROM • OTP memory • 16 bytes (EEPROM) SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 293 ISO transponder 8.10 MDS D200 6GT2600-1AD00-0AX0 Read cycles (at < 25 ℃) > 1014 Write cycles (at < 25 ℃) > 106 Data retention time (at < 25 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data of ISO transponders (MDS D) (Page 52)" MTBF (Mean Time Between Failures) 228 years Mechanical specifications Housing • Material • PET • Color • White Recommended distance to metal ≥ 20 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • During operation • -20 to +60 ℃ • During transportation and storage • -20 to +60 ℃ Degree of protection to EN 60529 IP67 Shock-resistant to EN 60721-3-7 class 7M3 ISO 10373 / ISO 7810 1) Vibration-resistant to EN 60721-3-7, class 7M3 ISO 10373 / ISO 7810 1) Torsion and bending load ISO 10373/ISO 7816-1 Design, dimensions and weight Dimensions (L x W x H) 85 x 54 x 0.8 mm Weight 5g Type of mounting • Fixing pocket • Glued 1) The values for shock and vibration are maximum values and must not be applied continuously. SIMATIC RF300 294 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.10 MDS D200 8.10.5 Dimension drawing Dimensions in mm Figure 8-23 Dimension drawing of MDS D200 SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 295 ISO transponder 8.11 MDS D261 8.11 MDS D261 8.11.1 Features MDS D261 Characteristics Area of application The design of the transponder (self-adhesive label) permits a variety of designs, guaranteeing optimum dimensioning for the widest variety of applications. From simple identification such as electronic barcode replacement/supplementation, through warehouse and distribution logistics, right up to product identification. 8.11.2 Memory size 256 bytes of EEPROM user memory Write/read range See section Field data of ISO transponders (MDS D) (Page 52). Mounting on metal Yes, with spacer ISO standard ISO 15693 Degree of protection IP65 Ordering data Table 8- 26 Ordering data for MDS D261 Article number MDS D261 6GT2600-1AA00-0AX0 Type of delivery Minimum order quantity: 1250 units (5 rolls with 250 units each) SIMATIC RF300 296 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.11 MDS D261 8.11.3 Technical data Table 8- 27 Technical specifications of MDS D261 6GT2600-1AA01-0AX0 Product type designation SIMATIC MDS D261 Memory Memory configuration • UID • 8 bytes • User memory • 256 bytes EEPROM • OTP memory • 16 bytes (EEPROM) Read cycles (at < 40 ℃) > 1014 Write cycles (at < 40 ℃) > 106 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data of ISO transponders (MDS D) (Page 52)" MTBF (Mean Time Between Failures) 228 years Mechanical specifications Housing • • Material Color • Top • PET plastic (label material) • Inlay • PET plastic (carrier material) • Antenna • Aluminum • Bottom • Double-sided transfer adhesive on silicon paper • White Recommended distance to metal ≥ 25 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • In operation, during write/read access • -5 to +85 °C • In operation, outside write/read access • -25 to +85 ℃ • During transportation and storage • +15 to +30 ℃ Can be stored for 2 years, determined by the durability of the adhesive Degree of protection IP65 SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 297 ISO transponder 8.11 MDS D261 6GT2600-1AA01-0AX0 Design, dimensions and weight 8.11.4 Dimensions (L x W x H) 55 x 55 x 0.3 mm Weight 1g Type of mounting Glued with self-adhesive label Dimension drawing Dimensions in mm Figure 8-24 Dimension drawing of MDS D261 SIMATIC RF300 298 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.12 MDS D324 8.12 MDS D324 8.12.1 Characteristics MDS D324 Characteristics Area of application Production and distribution logistics and product identification Can also be used in harsh environments under extreme environmental conditions (e.g. with higher temperature load). 8.12.2 Memory size 992 bytes of EEPROM user memory Write/read range See section "Field data of ISO transponders (MDS D) (Page 52)." Mounting on metal Yes, with spacer ISO standard ISO 15693 Degree of protection IP67; IPx9K Ordering data Table 8- 28 Ordering data MDS D324 Article number MDS D324 Table 8- 29 6GT2600-3AC00 Ordering data MDS D324 accessories Article number Spacer 6GT2690-0AK00 SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 299 ISO transponder 8.12 MDS D324 8.12.3 Mounting on metal Mounting on metal ≥ 15 mm Figure 8-25 Mounting the MDS D124/D324/D424/D524/E624 and RF320T on metal with spacer Flush-mounting ≥ 15 mm ≥ 25 mm Figure 8-26 Flush-mounting of the MDS D124/D324/D424/D524/E624 and RF320T in metal with spacer SIMATIC RF300 300 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.12 MDS D324 Note Going below the distances If the distances (a and h) are not observed, a reduction of the field data results. It is possible to mount the MDS with metal screws (M3 countersunk head screws). This has no tangible impact on the range. 8.12.4 Technical specifications Table 8- 30 Technical specifications of MDS D324 6GT2600-3AC00 Product type designation SIMATIC MDS D324 Memory Memory configuration • UID • 8 bytes • User memory • 992 bytes EEPROM • OPT memory • 16 bytes (EEPROM) Read cycles (at < 40 ℃) > 1014 Write cycles (at < 40 ℃) > 106 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data of ISO transponders (MDS D) (Page 52)" MTBF (Mean Time Between Failures) 228 years Mechanical specifications Housing • Material • Epoxy resin • Color • Black Recommended distance to metal ≥ 15 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • During operation • -25 to +125 ℃ • During transportation and storage • -40 to +140 ℃ SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 301 ISO transponder 8.12 MDS D324 6GT2600-3AC00 Degree of protection to EN 60529 • IP67 • IPx9K Shock-resistant to EN 60721-3-7 class 7M3 100 g 1) Vibration-resistant to EN 60721-3-7, class 7M3 20 g 1) Torsion and bending load Not permitted Design, dimensions and weight 8.12.5 Dimensions (Ø x H) 27 x 4 mm Weight 5g Type of mounting • 1 x M3 screw 2) ≤ 1 Nm • Glued 1) The values for shock and vibration are maximum values and must not be applied continuously. ) To prevent it loosening during operation, secure the screw with screw locking varnish. Dimension drawing Figure 8-27 Dimension drawing of MDS D324 All dimensions in mm SIMATIC RF300 302 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.13 MDS D339 8.13 MDS D339 8.13.1 Characteristics MDS D339 Characteristics Area of application Applications in production automation with high temperature demands (up to +220 °C) Typical application areas: 8.13.2 • Paintshops and their preparatory treatments • Primer coat, electrolytic dip area, cataphoresis with the associated drying furnaces • Top coat area with drying furnaces • Washing areas at temperatures > 85 °C • Other applications with higher temperatures Memory size 992 bytes of EEPROM user memory Write/read range See section Field data of ISO transponders (MDS D) (Page 52). Mounting on metal Yes, with spacer ISO standard ISO 15693 Degree of protection IP68/IPx9K Ordering data Table 8- 31 Ordering data for MDS D339 Article number MDS D339 Table 8- 32 6GT2600-3AA10 Ordering data for MDS D339 accessories Article number Spacer 6GT2690-0AA00 Quick change holder (Ø x H): 22 x 60 mm 6GT2690-0AH00 Quick change holder (Ø x H): 22 x 47 mm 6GT2690-0AH10 SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 303 ISO transponder 8.13 MDS D339 8.13.3 Mounting on metal Direct mounting of the MDS D139/D339 on metal is not allowed. A distance of ≥ 30 mm is recommended. This can be achieved using spacers (see "Ordering data (Page 303)"). Mounting on metal ≥ 30 mm Figure 8-28 Mounting the MDS D139/D339 on metal with spacer Flush-mounting It is possible to mount the MDS D139/D339 in metal. With large antennas, for example ANT D5, this leads to a reduction of ranges. ≥ 30 mm ≥ 100 mm Figure 8-29 Flush-mounting of the MDS D139/D339 in metal with spacer SIMATIC RF300 304 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.13 MDS D339 Note Going below the distances If the distances (a and h) are not observed, a reduction of the field data results. It is possible to mount the MDS with metal screws (M5). This has no tangible impact on the range. It is recommended that a test is performed in critical applications. 8.13.4 Cleaning the mobile data memory Note Do not clean the transponder with mechanical tools, sand-blasting or pressure hose. These cleaning methods result in damage to the transponder. Clean the transponder only with the cleaning agents listed in the section "Chemical resistance of the MDS". 8.13.5 Technical specifications Table 8- 33 Technical specifications of MDS D339 6GT2600-3AA10 Product type designation SIMATIC MDS D339 Memory Memory configuration • UID • 8 bytes • User memory • 992 bytes EEPROM • OPT memory • 16 bytes (EEPROM) Read cycles (at < 40 ℃) > 1014 Write cycles (at < 40 ℃) > 106 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data of ISO transponders (MDS D) (Page 52)" MTBF (Mean Time Between Failures) 228 years SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 305 ISO transponder 8.13 MDS D339 6GT2600-3AA10 Mechanical specifications Housing • Material • PPS • Color • Black Recommended distance to metal ≥ 30 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • • During operation During transportation and storage Degree of protection to EN 60529 • -25 to +220 ℃ • from +125 ℃: 20% reduction in the limit distance • from +140 ℃: No processing possible • at +200 ℃: Tested up to 5000 hours or 6000 cycles • at +220 ℃: Tested up to 2000 hours or 2000 cycles • -40 to +100 ℃ • IP68 2 hours, 2 bar, +20 °C • IPx9K steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75 °C Shock-resistant to EN 60721-3-7 class 7M3 50 g 1) Vibration-resistant to EN 60721-3-7, class 7M3 20 g 1) Torsion and bending load Not permitted Design, dimensions and weight Dimensions (Ø x H) 85 x 15 mm Weight 50 g Type of mounting 1 x M5 screw 2) 1.5 Nm The values for shock and vibration are maximum values and must not be applied continuously. 2) For mounting with the spacer (6GT2690-0AA00), use a stainless steel M5 screw to avoid damaging the MDS in high temperatures (expansion coefficient). SIMATIC RF300 306 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.13 MDS D339 8.13.6 Use of the MDS D339 in hazardous areas The MDS D339 mobile data memory is classed as a piece of simple, electrical equipment and can be operated in Protection Zone 2, Device Group II, Category 3G. The following requirements of the 94/9/EC directive are met: ● EN 60079-0:2006 ● EN 60079-15:2005 ● EN 61241-0:2006 ● EN 61241-1:2004 Identification II 3 G Ex nA II T6 Ii 3 D Ex tD A22 IP68 T 210°C KEMA 09 ATEX 0133 X WARNING Gefahr durch elektrostatische Entladungen Potential electrostatic charging hazard Danger potentiel de charges électrostatiques SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 307 ISO transponder 8.13 MDS D339 Note Installations- und Betriebsbedingungen für den Ex-Schutzbereich: a) Der Einsatz des Gerätes in der Nähe von stark ladungserzeugenden Prozessen ist untersagt. b) Das Gerät ist mechanisch geschützt zu montieren. c) Die Montage muss auf einem geerdeten, leitenden Untergrund erfolgen. d) Die Reinigung darf nur mit feuchtem Tuch erfolgen. Installation and operating conditions for hazardous areas: a) Use of the equipment in the vicinity of processes generating high charges is not allowed. b) The equipment must be mechanically protected when installed. c) Installation must be performed on a grounded and conductive mounting surface. d) Cleaning only with a wet cloth Conditions d'installation et de mise en oeuvre pour la zone de protection Ex : a) L'utilisation de l'appareil près de processus générant de fortes charges est interdite. b) L'appareil doit être monté de manière à être protégé mécaniquement. c) Le montage doit être effectué sur un socle conducteur mis à la terre. d) Nettoyage uniquement avec un chiffon humide SIMATIC RF300 308 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.13 MDS D339 8.13.7 Dimensional drawing MDS D339 Figure 8-30 Dimension drawing of the MDS D339 Dimensions in mm SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 309 ISO transponder 8.14 MDS D400 8.14 MDS D400 8.14.1 Features MDS D400 8.14.2 Characteristics Area of application Simple identification such as electronic barcode replacement/supplements, from warehouse and distribution logistics right through to product identification. Memory size 2000 bytes of FRAM user memory Write/read range See section "Field data of ISO transponders (MDS D) (Page 52)" Mounting on metal Yes, with spacer ISO standard ISO 15693 Degree of protection IP67 Ordering data Table 8- 34 Ordering data of MDS D400 Article number MDS D400 Table 8- 35 6GT2600-4AD00 Ordering data of MDS D400 accessories Article number Spacer (in conjunction with fixing pocket 6GT2190-0AB00) 6GT2190-0AA00 Fixing pocket (in conjunction with spacer 6GT2190-0AA00) 6GT2190-0AB00 Fixing pocket (not suitable for fixing directly onto metal) 6GT2390-0AA00 SIMATIC RF300 310 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.14 MDS D400 8.14.3 Mounting on metal Mounting on metal It is possible to mount the MDS D400 on metal. ① ② ③ ≥ 20 mm Transponder Metal Non-metal Figure 8-31 Mounting of the MDS D400 on metal with spacer SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 311 ISO transponder 8.14 MDS D400 Flush-mounted in metal ≥ 20 mm ≥ 20 mm ① ② ③ Transponder Metal Non-metal Figure 8-32 Flush-mounting of MDS D400 in metal with spacer Note If the minimum guide values (h) are not observed, this will result in a reduction of the field data. 8.14.4 Technical specifications Table 8- 36 Technical specifications for MDS D400 6GT2600-1AD00-0AX0 Product type designation SIMATIC MDS D400 Memory Memory configuration • UID • 8 bytes • User memory • 256 bytes FRAM • OPT memory • 16 bytes FRAM SIMATIC RF300 312 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.14 MDS D400 6GT2600-1AD00-0AX0 Read cycles (at < 25 ℃) > 1012 Write cycles (at < 25 ℃) > 1012 Data retention time (at < 25 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data of ISO transponders (MDS D) (Page 52)" MTBF (Mean Time Between Failures) 228 years Mechanical specifications Housing • Material • PVC • Color • White Recommended distance to metal ≥ 20 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • During operation • -20 to +60 ℃ • During transportation and storage • -20 to +60 ℃ Degree of protection to EN 60529 IP67 Vibration-resistant to EN 60721-3-7, class 7M3 ISO 10373 / ISO 7810 1) Torsion and bending load ISO 10373/ISO 7816-1 Design, dimensions and weight Dimensions (L x W x H) 85 x 54 x 0.8 mm Weight 5g Type of mounting • Fixing lug • Glued 1) The values for vibration are maximum values and must not be applied continuously. SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 313 ISO transponder 8.14 MDS D400 8.14.5 Dimension drawing Figure 8-33 Dimensional drawing MDS D400 (dimensions in mm) SIMATIC RF300 314 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.15 MDS D421 8.15 MDS D421 8.15.1 Characteristics MDS D421 Characteristics Area of application The MDS D421 is designed for tool coding in accordance with DIN 69873. It can be used wherever small data carriers and exact positioning are required, e.g. tool identification, workpiece holders. The rugged housing of the MDS D421 means that it can also be used in a harsh industrial environment without problems. 8.15.2 Memory size 2000 bytes of FRAM user memory Write/read range See section "Field data of ISO transponders (MDS D) (Page 52)" Mounting on metal Yes, flush-mounted in metal ISO standard ISO 15693 Degree of protection IP67/IPx9K Ordering data Table 8- 37 Ordering data of MDS D421 Article number MDS D421 6GT2600-4AE00 SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 315 ISO transponder 8.15 MDS D421 8.15.3 Mounting on metal Mounting on metal Figure 8-34 Mounting of MDS D421/D521/E623 on metal Figure 8-35 Mounting of MDS D421/D521/E623 in metal Flush-mounting SIMATIC RF300 316 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.15 MDS D421 Flush-mounting of the MDS in metal with tools Figure 8-36 Flush-mounting of MDS D421/D521/E623 in metal with tools b1 0.5 x 45° b2 0.3 x 45° or R0.3 d1 10 (-0.04... -0.13) d2 10 (+0.09... 0) t1 4.5 (-0 ... -0.1) t2 4.6 (+0.2 ... 0) All dimensions in mm Note Installation instruction The MDS should not protrude out of the locating hole; it must be flush with the outside contour. The mounting instructions of the MDS and the conditions associated with the application (e.g. peripheral speed, temperature, and use of coolant) must be observed during the installation. Mounting information for adhesion ● Drill installation hole ● The adhesive surfaces must be dry, free from dust, oil, stripping agents and other impurities ● Apply adhesive according to the manufacturer's processing instructions ● Press in transponder using your fingers; with antenna side to the outside (see figure above) ● Remove residues of adhesive ● Allow to cure according to the manufacturer's instructions ● Flush-mounting of the transponder in metal with tools SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 317 ISO transponder 8.15 MDS D421 Installation examples 8.15.4 Figure 8-37 Installation example of MDS D421/D521/E623 in a steep cone Figure 8-38 Installation example of MDS D421/D521/E623 in a stud bolt Technical specifications Table 8- 38 Technical specifications for the MDS D421 6GT2600-4AE00 Product type designation SIMATIC MDS D421 Memory Memory configuration • UID • 8 bytes • User memory • 2000 bytes FRAM • OPT memory • 16 bytes FRAM Read cycles (at < 40 ℃) > 1012 Write cycles (at < 40 ℃) > 1012 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data of ISO transponders (MDS D) (Page 52)" MTBF (Mean Time Between Failures) 228 years SIMATIC RF300 318 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.15 MDS D421 6GT2600-4AE00 Mechanical specifications Housing • Material • Epoxy resin • Color • Black Recommended distance to metal ≥ 0 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • During operation • -25 to +85 ℃ • During transportation and storage • -40 to +100 ℃ • IP67 • IPx9K steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75 °C Degree of protection to EN 60529 Shock-resistant to EN 60721-3-7 class 7M3 100 g 1) Vibration-resistant to EN 60721-3-7, class 7M3 20 g 1) Torsion and bending load Not permitted Design, dimensions and weight Dimensions (Ø x H) 10 x 4.5 mm Weight Approx. 1 g Type of mounting Glued2) 1) The values for shock and vibration are maximum values and must not be applied continuously. 2) The manufacturer's processing instructions must be observed. SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 319 ISO transponder 8.15 MDS D421 8.15.5 Dimension drawing Figure 8-39 Dimension drawing of MDS D421 All dimensions in mm SIMATIC RF300 320 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.16 MDS D422 8.16 MDS D422 8.16.1 Characteristics MDS D422 8.16.2 Characteristics Area of application Identification of metallic workpiece holders, workpieces or containers Memory size 2000 bytes of FRAM user memory Write/read range See section "Field data of ISO transponders (MDS D) (Page 52). Mounting on metal Yes ISO standard ISO 15693 Degree of protection IP68 Ordering data Table 8- 39 Ordering data of MDS D422 Article number MDS D422 6GT2600-4AF00 A screw-in aid is included in the scope of supply per packaging unit SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 321 ISO transponder 8.16 MDS D422 8.16.3 Mounting in metal Flush-mounting Figure 8-40 Mounting of MDS D422 in metal Mounting information for screws You can screw the transponder into a pre-drilled threaded hole using the screw-in aid. Mounting information for adhesion ● Drill installation hole ● The adhesive surfaces must be dry, free from dust, oil, stripping agents and other impurities ● Apply adhesive according to the manufacturer's processing instructions ● Press in MDS D422 using your fingers; with antenna to the outside ● Remove residues of adhesive ● Allow to cure according to the manufacturer's instructions ● Flush-mounting of MDS D422 in metal with tools SIMATIC RF300 322 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.16 MDS D422 8.16.4 Technical specifications Table 8- 40 Technical specifications for the MDS D422 6GT2600-4AF00 Product type designation SIMATIC MDS D422 Memory Memory configuration • UID • 8 bytes • User memory • 2000 bytes FRAM • OPT memory • 16 bytes FRAM Read cycles (at < 40 ℃) > 1012 Write cycles (at < 40 ℃) > 1012 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data of ISO transponders (MDS D) (Page 52)" MTBF (Mean Time Between Failures) 285 years Mechanical specifications Housing • Material • Plastic PA 6.6 GF; brass nickel plated • Color • Black/silver Recommended distance to metal ≥ 0 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • During operation • -25 to +85 ℃ • During transportation and storage • -40 to +100 ℃ Degree of protection to EN 60529 • IP68 2 hours, 2 bar, +20 °C Shock-resistant to EN 60721-3-7 class 7M3 50 g 1) Vibration-resistant to EN 60721-3-7, class 7M3 20 g 1) Torsion and bending load Not permitted SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 323 ISO transponder 8.16 MDS D422 6GT2600-4AF00 Design, dimensions and weight Dimensions (Ø x H) 20 x 6 mm Weight 13 g Type of mounting • Glued • 1 x transponder thread M20 ≤ 1 Nm 1) 8.16.5 The values for shock and vibration are maximum values and must not be applied continuously. Dimension drawing Dimensions in mm Figure 8-41 Dimensional drawing of MDS D422 SIMATIC RF300 324 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.17 MDS D423 8.17 MDS D423 8.17.1 Characteristics MDS D423 8.17.2 Characteristics Area of application Identification of metallic workpiece holders, workpieces or containers, production automation Memory size 2000 bytes of FRAM user memory Write/read range See section "Field data of ISO transponders (MDS D) (Page 52)" Mounting on metal Yes, flush-mounted in metal ISO standard ISO 15693 Degree of protection IP68/IPx9K Ordering data Table 8- 41 Ordering data of MDS D423 Article number MDS D423 Table 8- 42 6GT2600-4AA00 Ordering data of MDS D423 accessories Article number Fixing hood RF330T / MDS D423 6GT2690-0EA00 SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 325 ISO transponder 8.17 MDS D423 8.17.3 Mounting on metal Mounting on metal Direct mounting of the MDS D423 on metal is possible. Figure 8-42 Mounting the MDS D423 on metal Flush-mounted in metal It is possible to mount the MDS D423 in metal. ≥ 10 mm Figure 8-43 Flush-mounting of the MDS D423 in metal with 10 mm clearance SIMATIC RF300 326 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.17 MDS D423 Figure 8-44 Flush-mounting of the MDS D423 in metal without clearance Note Reduction of the write/read range Note that when the device is flush-mounted in metal without a surrounding clearance ≥ 10 mm, the write/read range is significantly reduced. 8.17.4 Technical specifications Table 8- 43 Technical specifications of MDS D423 6GT2600-4AA00 Product type designation SIMATIC MDS D423 Memory Memory configuration • UID • 8 bytes • User memory • 2000 bytes FRAM • OPT memory • 16 bytes FRAM Read cycles (at < 40 ℃) > 1012 Write cycles (at < 40 ℃) > 1012 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data of ISO transponders (MDS D) (Page 52)" MTBF (Mean Time Between Failures) 228 years SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 327 ISO transponder 8.17 MDS D423 6GT2600-4AA00 Mechanical specifications Housing • Material • Plastic PPS • Color • Black Recommended distance to metal ≥ 0 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • During operation • -25 to +85 ℃ • During transportation and storage • -40 to +100 ℃ • IP68 2 hours, 2 bar, +20 °C • IPx9K steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75 °C Degree of protection to EN 60529 Shock-resistant to EN 60721-3-7 class 7M3 50 g 1) Vibration-resistant to EN 60721-3-7, class 7M3 20 g 1) Pressure resistance • Low pressure resistant vacuum dryer: up to 20 mbar • High pressure resistant (see degree of protection IPx9K) Torsion and bending load Not permitted Design, dimensions and weight Dimensions (Ø x H) 30 x 8 mm Weight 15 g Type of mounting 1 x M4 screw 2) ≤ 1 Nm 1) The values for shock and vibration are maximum values and must not be applied continuously. ) To prevent it loosening during operation, secure the screw with screw locking varnish. SIMATIC RF300 328 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.17 MDS D423 8.17.5 Dimensional drawing Dimensions in mm Figure 8-45 Dimension drawing for MDS D423 SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 329 ISO transponder 8.18 MDS D424 8.18 MDS D424 8.18.1 Characteristics MDS D424 Characteristics Area of application Production and distribution logistics as well as in assembly and production lines, can also be used in a harsh industrial environment without problem 8.18.2 Memory size 2000 bytes of FRAM user memory Write/read range See section "Field data of ISO transponders (MDS D) (Page 52)." Mounting on metal Yes, with spacer ISO standard ISO 15693 Degree of protection IP67; IPx9K Ordering data Table 8- 44 Ordering data of MDS D424 Article number MDS D424 Table 8- 45 6GT2600-4AC00 Ordering data of MDS D424 accessories Article number Spacer 6GT2690-0AK00 SIMATIC RF300 330 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.18 MDS D424 8.18.3 Mounting on metal Mounting on metal ≥ 15 mm Figure 8-46 Mounting the MDS D124/D324/D424/D524/E624 and RF320T on metal with spacer Flush-mounting ≥ 15 mm ≥ 25 mm Figure 8-47 Flush-mounting of the MDS D124/D324/D424/D524/E624 and RF320T in metal with spacer SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 331 ISO transponder 8.18 MDS D424 Note Going below the distances If the distances (a and h) are not observed, a reduction of the field data results. It is possible to mount the MDS with metal screws (M3 countersunk head screws). This has no tangible impact on the range. 8.18.4 Technical specifications Table 8- 46 Technical specifications for the MDS D424 6GT2600-4AC00 Product type designation SIMATIC MDS D424 Memory Memory configuration • UID • 8 bytes • User memory • 2000 bytes FRAM • OPT memory • 16 bytes FRAM Read cycles (at < 40 ℃) > 1012 Write cycles (at < 40 ℃) > 1012 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data of ISO transponders (MDS D) (Page 52)" MTBF (Mean Time Between Failures) 228 years Mechanical specifications Housing • Material • Epoxy resin • Color • Black Recommended distance to metal ≥ 15 mm Power supply Inductive, without battery SIMATIC RF300 332 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.18 MDS D424 6GT2600-4AC00 Permitted ambient conditions Ambient temperature • During operation • -25 to +85 ℃ • During transportation and storage • -40 to +100 ℃ • IP67 • IPx9K Degree of protection to EN 60529 Shock-resistant to EN 60721-3-7 class 7M3 100 g 1) Vibration-resistant to EN 60721-3-7, class 7M3 20 g 1) Torsion and bending load Not permitted Design, dimensions and weight 8.18.5 Dimensions (Ø x H) 27 x 4 mm Weight 5g Type of mounting • Glued • 1 x M3 screw 2) ≤ 1 Nm 1) The values for shock and vibration are maximum values and must not be applied continuously. ) To prevent it loosening during operation, secure the screw with screw locking varnish. Dimension drawing Figure 8-48 Dimension drawing of MDS D424 All dimensions in mm SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 333 ISO transponder 8.19 MDS D425 8.19 MDS D425 8.19.1 Characteristics MDS D425 Characteristics Area of application Compact and rugged ISO transponder; suitable for screw mounting Use in assembly and production lines in the powertrain sector; ideal for mounting on motors, gearboxes, and workpiece holders Rugged packaging of the MDS D425; can therefore also be used under extreme environmental conditions without problem 8.19.2 Memory size 2000 bytes of FRAM user memory Write/read range See section "Field data of ISO transponders (MDS D) (Page 52)". Mounting on metal Yes ISO standard ISO 15693 Degree of protection IP68/IPx9K Ordering data Table 8- 47 Ordering data of MDS D425 Article number MDS D425 6GT2600-4AG00 SIMATIC RF300 334 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.19 MDS D425 8.19.3 Application example Figure 8-49 8.19.4 Application example Technical specifications Table 8- 48 Technical specifications for the MDS D425 6GT2600-4AG00 Product type designation SIMATIC MDS D425 Memory Memory configuration • UID • 8 bytes • User memory • 2000 bytes FRAM • OPT memory • 16 bytes FRAM Read cycles (at < 40 ℃) > 1012 Write cycles (at < 40 ℃) > 1012 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data of ISO transponders (MDS D) (Page 52)" MTBF (Mean Time Between Failures) 228 years SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 335 ISO transponder 8.19 MDS D425 6GT2600-4AG00 Mechanical specifications Housing • Material • Plastic PA 6.6 GF • Color • Black Recommended distance to metal ≥ 0 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • During operation • -25 to +85 ℃ • During transportation and storage • -40 to +125 ℃ • IP68 2 hours, 2 bar, +20 °C • IPx9K steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75 °C Degree of protection to EN 60529 Shock-resistant to IEC 68-2-27 50 g 1) Vibration-resistant to IEC 68-2-6 20 g 1) Torsion and bending load Not permitted Design, dimensions and weight Dimensions (Ø x H) 24 x 10 mm (without set screw) Weight 35 g Type of mounting 1x transponder set screw M6 SW 22; ≤ 6 Nm 1) The values for shock and vibration are maximum values and must not be applied continuously. SIMATIC RF300 336 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.19 MDS D425 8.19.5 Dimension drawing Dimensions in mm Figure 8-50 Dimension drawing of MDS D425 SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 337 ISO transponder 8.20 MDS D426 8.20 MDS D426 8.20.1 Characteristics MDS D426 8.20.2 Characteristics Area of application Compact and rugged ISO transponder; suitable for identification of transport units in production-related logistics; can also be deployed in harsh conditions Memory size 2000 bytes of FRAM user memory Write/read range See section Field data of ISO transponders (MDS D) (Page 52) Mounting on metal Yes, with spacer ISO standard ISO 15693 Degree of protection IP68 Ordering data Table 8- 49 Ordering data of MDS D426 Article number MDS D426 Table 8- 50 6GT2600-4AH00 Ordering data of MDS D426 accessories Article number Spacer 6GT2690-0AL00 SIMATIC RF300 338 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.20 MDS D426 8.20.3 Mounting on metal Mounting on metal ≥ 25 mm Figure 8-51 Mounting the MDS D126 / D426 / D526 on metal with spacer Flush-mounted in metal ≥ 25 mm ≥ 50 mm Figure 8-52 Flush installation of the MDS D126 / D426 / D526 in metal with spacer SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 339 ISO transponder 8.20 MDS D426 8.20.4 Technical specifications Table 8- 51 Technical specifications for the MDS D426 6GT2600-4AH00 Product type designation SIMATIC MDS D426 Memory Memory configuration • UID • 8 bytes • User memory • 2000 bytes FRAM • OPT memory • 16 bytes FRAM Read cycles (at < 40 ℃) > 1012 Write cycles (at < 40 ℃) > 1012 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data of ISO transponders (MDS D) (Page 52)" MTBF (Mean Time Between Failures) 228 years Mechanical specifications Housing • Material • Plastic PA 6.6 GF • Color • Black Recommended distance to metal ≥ 25 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • During operation • -25 to +85 ℃ • During transportation and storage • -40 to +100 ℃ Degree of protection to EN 60529 IP68 2 hours, 2 bar, +20 °C Shock-resistant to IEC 68-2-27 50 g 1) Vibration-resistant to IEC 68-2-6 20 g 1) Torsion and bending load Not permitted SIMATIC RF300 340 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.20 MDS D426 6GT2600-4AH00 Design, dimensions and weight 8.20.5 Dimensions (Ø x H) 50 x 3.6 mm Weight 13 g Type of mounting 1 x M4 screw 2) ≤ 1 Nm 1) The values for shock and vibration are maximum values and must not be applied continuously. ) To prevent it loosening during operation, secure the screw with screw locking varnish. Dimension drawing Dimensions in mm Figure 8-53 Dimension drawing of MDS D426 SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 341 ISO transponder 8.21 MDS D428 8.21 MDS D428 8.21.1 Characteristics MDS D428 Characteristics Area of application Compact and rugged ISO transponder; suitable for screw mounting. Use in assembly and production lines in the powertrain sector. The rugged housing of the MDS D428 means that it can also be used in extreme environmental conditions without problems. 8.21.2 Memory size 2000 bytes of FRAM user memory Write/read range See section "Field data of ISO transponders (MDS D) (Page 52)" Mounting on metal Yes ISO standard ISO 15693 Degree of protection IP68/IPx9K Ordering data Table 8- 52 Ordering data of MDS D428 Article number MDS D428 6GT2600-4AK00-0AX0 SIMATIC RF300 342 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.21 MDS D428 8.21.3 Application example Figure 8-54 8.21.4 Application example Technical specifications Table 8- 53 Technical specifications for the MDS D428 6GT2600-4AK00 Product type designation SIMATIC MDS D428 Memory Memory configuration • UID • 8 bytes • User memory • 2000 bytes FRAM • OPT memory • 16 bytes FRAM Read cycles (at < 40 ℃) > 1012 Write cycles (at < 40 ℃) > 1012 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data of ISO transponders (MDS D) (Page 52)" MTBF (Mean Time Between Failures) 228 years SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 343 ISO transponder 8.21 MDS D428 6GT2600-4AK00 Mechanical specifications Housing • Material • Plastic PA 6.6 GF • Color • Black Recommended distance to metal ≥ 0 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • During operation • -25 to +85 ℃ • During transportation and storage • -40 to +125 ℃ • IP68 2 hours, 2 bar, +20 °C • IPx9K steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75 °C Degree of protection to EN 60529 Shock-resistant to IEC 68-2-27 50 g 1) Vibration-resistant to IEC 68-2-6 20 g 1) Torsion and bending load Not permitted Design, dimensions and weight Dimensions (Ø x H) 24 x 20 mm (without set screw) Weight 35 g Type of mounting 1x transponder set screw M8 SW 22; ≤ 8 Nm 1) The values for shock and vibration are maximum values and must not be applied continuously. SIMATIC RF300 344 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.21 MDS D428 8.21.5 Dimension drawing Dimensions in mm Figure 8-55 Dimension drawing of MDS D428 SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 345 ISO transponder 8.22 MDS D460 8.22 MDS D460 8.22.1 Characteristics MDS D460 8.22.2 Characteristics Area of application Identification in small assembly lines; can also be used in a harsh industrial environment Memory size 2000 bytes of FRAM user memory Write/read range See section "Field data of ISO transponders (MDS D) (Page 52). Mounting on metal Yes, with spacer ISO standard ISO 15693 Degree of protection IP67/IPx9K Ordering data Table 8- 54 Ordering data of MDS D460 Article number MDS D460 Table 8- 55 6GT2600-4AB00 Ordering data of MDS D460 accessories Article number Spacer 6GT2690-0AG00 SIMATIC RF300 346 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.22 MDS D460 8.22.3 Mounting on metal Mounting option on metal with spacer ① ② ③ Transponder ≥ 10 mm Metal Spacer Figure 8-56 Mounting the MDS D460 on metal with spacer Note If the minimum guide values (h) are not observed, a reduction of the field data results. In critical applications, it is recommended that a test is performed. Flush-mounting Flush-mounting of the MDS D460 in metal is not permitted! 8.22.4 Technical specifications Table 8- 56 Technical specifications for MDS D460 6GT2600-4AB00 Product type designation SIMATIC MDS D460 Memory Memory configuration • UID • 8 bytes • User memory • 2000 bytes FRAM • OPT memory • 16 bytes FRAM SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 347 ISO transponder 8.22 MDS D460 6GT2600-4AB00 Read cycles (at < 40 ℃) > 1012 Write cycles (at < 40 ℃) > 1012 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data of ISO transponders (MDS D) (Page 52)" MTBF (Mean Time Between Failures) 228 years Mechanical specifications Housing • Material • Epoxy resin • Color • Black Recommended distance to metal ≥ 10 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • During operation • -25 to +85 ℃ • During transportation and storage • -40 to +100 ℃ Degree of protection to EN 60529 • IP67 • IPx9K steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75 °C Shock-resistant to IEC 68-2-27 50 g 1) Vibration-resistant to IEC 68-2-6 20 g 1) Torsion and bending load Not permitted Design, dimensions and weight Dimensions (Ø x H) 16 x 3 mm Weight 3g Type of mounting • Glued • With spacer 1) The values for shock and vibration are maximum values and must not be applied continuously. SIMATIC RF300 348 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.22 MDS D460 8.22.5 Dimension drawings Dimensional drawing of MDS D460 Dimensions in mm Figure 8-57 Dimensional drawing of MDS D460 Dimensional drawing of spacer Dimensions in mm Figure 8-58 Dimensional drawing of spacer SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 349 ISO transponder 8.23 MDS D521 8.23 MDS D521 8.23.1 Characteristics MDS D521 Characteristics Area of application The MDS D521 is designed for tool coding according to DIN 69873. It can be used wherever small data carriers and exact positioning are required, e.g. tool identification, workpiece holders. The rugged housing of the MDS D521 means that it can also be used in a harsh industrial environment without problems. 8.23.2 Memory size 8192 bytes of FRAM user memory Write/read range See section "Field data of ISO transponders (MDS D) (Page 52)" Mounting on metal Yes, flush-mounted in metal ISO standard ISO 15693 Degree of protection IP67/IPx9K Ordering data Table 8- 57 Ordering data for MDS D521 Article number MDS D521 8.23.3 6GT2600-5AE00 Mounting on metal Mounting on metal Figure 8-59 Mounting of MDS D421/D521/E623 on metal SIMATIC RF300 350 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.23 MDS D521 Flush-mounting Figure 8-60 Mounting of MDS D421/D521/E623 in metal Flush-mounting of the MDS in metal with tools Figure 8-61 Flush-mounting of MDS D421/D521/E623 in metal with tools b1 0.5 x 45° b2 0.3 x 45° or R0.3 d1 10 (-0.04... -0.13) d2 10 (+0.09... 0) t1 4.5 (-0 ... -0.1) t2 4.6 (+0.2 ... 0) All dimensions in mm Note Installation instruction The MDS should not protrude out of the locating hole; it must be flush with the outside contour. The mounting instructions of the MDS and the conditions associated with the application (e.g. peripheral speed, temperature, and use of coolant) must be observed during the installation. SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 351 ISO transponder 8.23 MDS D521 Mounting information for adhesion ● Drill installation hole ● The adhesive surfaces must be dry, free from dust, oil, stripping agents and other impurities ● Apply adhesive according to the manufacturer's processing instructions ● Press in transponder using your fingers; with antenna side to the outside (see figure above) ● Remove residues of adhesive ● Allow to cure according to the manufacturer's instructions ● Flush-mounting of the transponder in metal with tools Installation examples Figure 8-62 Installation example of MDS D421/D521/E623 in a steep cone Figure 8-63 Installation example of MDS D421/D521/E623 in a stud bolt SIMATIC RF300 352 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.23 MDS D521 8.23.4 Technical specifications Table 8- 58 Technical specifications for MDS D521 6GT2600-5AE00 Product type designation SIMATIC MDS D521 Memory Memory configuration • UID • 8 bytes • User memory • 8192 bytes FRAM Read cycles (at < 40 ℃) > 1012 Write cycles (at < 40 ℃) > 1012 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data of ISO transponders (MDS D) (Page 52)" MTBF (Mean Time Between Failures) 228 years Mechanical specifications Housing • Material • Epoxy resin • Color • Black Recommended distance to metal > 25 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • During operation • -25 to +85 ℃ • During transportation and storage • -40 to +100 ℃ Degree of protection to EN 60529 • IP67 • IPx9K steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75 °C Shock-resistant to EN 60721-3-7 class 7M3 100 g 1) Vibration-resistant to EN 60721-3-7, class 7M3 20 g 1) Torsion and bending load Not permitted SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 353 ISO transponder 8.23 MDS D521 6GT2600-5AE00 Design, dimensions and weight 8.23.5 Dimensions (Ø x H) 10 x 4.5 mm Weight 4g Type of mounting Glued2) 1) The values for shock and vibration are maximum values and must not be applied continuously. 2) The manufacturer's processing instructions must be observed. Dimension drawing Figure 8-64 Dimension drawing of MDS D521 All dimensions in mm SIMATIC RF300 354 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.24 MDS D522 8.24 MDS D522 8.24.1 Characteristics MDS D522 8.24.2 Characteristics Area of application Identification of metallic workpiece holders, workpieces or containers Memory size 8192 bytes of FRAM user memory Write/read range See "Field data of ISO transponders (MDS D) (Page 52)." Mounting in metal Yes ISO standard ISO 15693 Degree of protection IP68 Ordering data Table 8- 59 Ordering data for MDS D522 Article number MDS D522 6GT2600-5AF00 Units in a package: 10 units A mounting aid is included in the scope of supply per packaging unit. 8.24.3 Mounting in metal Flush-mounting Figure 8-65 Mounting of MDS D522 in metal SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 355 ISO transponder 8.24 MDS D522 Mounting information for screws You can screw the transponder into a pre-drilled threaded hole using the screw-in aid. Mounting information for adhesion ● Drill installation hole ● The adhesive surfaces must be dry, free from dust, oil, stripping agents and other impurities ● Apply adhesive according to the manufacturer's processing instructions ● Press in MDS D522 using your fingers; with antenna to the outside ● Remove residues of adhesive ● Allow to cure according to the manufacturer's instructions ● Flush-mounting of MDS D522 in metal with tools 8.24.4 Technical specifications Table 8- 60 Technical specifications for MDS D522 6GT2600-5AF00 Product type designation SIMATIC MDS D522 Memory Memory configuration • UID • 8 bytes • User memory • 8192 bytes FRAM Read cycles (at < 40 ℃) > 1012 Write cycles (at < 40 ℃) > 1012 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data of ISO transponders (MDS D) (Page 52)" MTBF (Mean Time Between Failures) 285 years Mechanical specifications Housing • Material • Plastic PA 6.6 GF; brass nickel plated • Color • Black/silver Recommended distance to metal ≥ 0 mm Power supply Inductive, without battery SIMATIC RF300 356 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.24 MDS D522 6GT2600-5AF00 Permitted ambient conditions Ambient temperature • During operation • -25 to +85 ℃ • During transportation and storage • -40 to +100 ℃ Degree of protection to EN 60529 • IP68 2 hours, 2 bar, +20 °C Shock-resistant to EN 60721-3-7 class 7M3 50 g 1) Vibration-resistant to EN 60721-3-7, class 7M3 20 g 1) Torsion and bending load Not permitted Design, dimensions and weight Dimensions (Ø x H) 20 x 6 mm Weight 13 g Type of mounting • Glued • 1 x transponder thread M20 ≤ 1 Nm 1) 8.24.5 The values for shock and vibration are maximum values and must not be applied continuously. Dimension drawing Figure 8-66 Dimensional drawing of MDS D522 All dimensions in mm SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 357 ISO transponder 8.25 MDS D522 special variant 8.25 MDS D522 special variant 8.25.1 Characteristics MDS D522 special version 8.25.2 Characteristics Area of application Identification of metallic workpiece holders or workpieces Memory size 8192 bytes of FRAM user memory Write/read range See "Field data of ISO transponders (MDS D) (Page 52)." Mounting in metal Yes ISO standard ISO 15693 Degree of protection IP68 Ordering data Table 8- 61 MDS D522 special version Article number MDS D522 special version 6GT2600-5AF00-0AX0 Units in a package: 10 units A mounting aid is included in the scope of supply per packaging unit. SIMATIC RF300 358 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.25 MDS D522 special variant 8.25.3 Mounting in metal Flush-mounting Figure 8-67 8.25.4 Flush installation of the MDS D522 special version in metal without clearance Installation instructions The transponder MDS D522 special version is designed to be mounted once. Note the following instructions when mounting the MDS D522 in a workpiece to avoid damaging the transponder: ● Prepare the workpiece according to the following drawing. ● Using the accompanying mounting aid, press the transponder with uniform and evenly distributed pressure into the drilled hole until the transponder locks in place. Make sure that the transponder does not become tilted. SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 359 ISO transponder 8.25 MDS D522 special variant Figure 8-68 Dimension drawing: Workpiece drill hole for mounting the MDS D522 special version SIMATIC RF300 360 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.25 MDS D522 special variant 8.25.5 Technical specifications Table 8- 62 Technical data of MDS D522 special version 6GT2600-5AF00-0AX0 Product type designation SIMATIC MDS D522 special version Memory Memory configuration • UID • 8 bytes • User memory • 8192 bytes FRAM Read cycles (at < 40 ℃) > 1012 Write cycles (at < 40 ℃) > 1012 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data of ISO transponders (MDS D) (Page 52)" MTBF (Mean Time Between Failures) 228 years Mechanical specifications Housing • Material • Plastic PA 6.6 GF • Color • Black Recommended distance to metal ≥ 0 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • During operation • -25 to +85 ℃ • During transportation and storage • -40 to +100 ℃ Degree of protection to EN 60529 IP68 2 hours, 2 bar, +20 °C Shock-resistant to EN 60721-3-7 class 7M3 50 g 1) Vibration-resistant to EN 60721-3-7, class 7M3 20 g 1) Torsion and bending load Not permitted Design, dimensions and weight Dimensions (Ø x H) 18 (+0.1) × 5.2 mm Weight Approx. 1.2 g Type of mounting Clipping in once (with accompanying tool) 1) The values for shock and vibration are maximum values and must not be applied continuously. SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 361 ISO transponder 8.25 MDS D522 special variant 8.25.6 Dimensional drawing Figure 8-69 Dimension drawing MDS D522 special version All dimensions in mm SIMATIC RF300 362 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.26 MDS D524 8.26 MDS D524 8.26.1 Characteristics MDS D524 Characteristics Area of application Production and distribution logistics as well as in assembly and production lines, can also be used in a harsh industrial environment without problem 8.26.2 Memory size 8192 bytes of FRAM user memory Write/read range See section "Field data of ISO transponders (MDS D) (Page 52)." Mounting on metal Yes, with spacer ISO standard ISO 15693 Degree of protection IP67; IPx9K Ordering data Table 8- 63 Ordering data for MDS D524 Article number MDS D524 Table 8- 64 6GT2600-5AC00 Ordering data of MDS D524 accessories Article number Spacer 6GT2690-0AK00 SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 363 ISO transponder 8.26 MDS D524 8.26.3 Mounting on metal Mounting on metal ≥ 15 mm Figure 8-70 Mounting the MDS D124/D324/D424/D524/E624 and RF320T on metal with spacer Flush-mounting ≥ 15 mm ≥ 25 mm Figure 8-71 Flush-mounting of the MDS D124/D324/D424/D524/E624 and RF320T in metal with spacer SIMATIC RF300 364 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.26 MDS D524 Note Going below the distances If the distances (a and h) are not observed, a reduction of the field data results. It is possible to mount the MDS with metal screws (M3 countersunk head screws). This has no tangible impact on the range. 8.26.4 Technical specifications Table 8- 65 Technical specifications for MDS D524 6GT2600-5AC00 Product type designation SIMATIC MDS D524 Memory Memory configuration • UID • 8 bytes • User memory • 8192 bytes FRAM Read cycles (at < 40 ℃) > 1012 Write cycles (at < 40 ℃) > 1012 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data of ISO transponders (MDS D) (Page 52)" MTBF (Mean Time Between Failures) 228 years Mechanical specifications Housing • Material • Epoxy resin • Color • Black Recommended distance to metal ≥ 25 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • During operation • -25 to +85 ℃ • During transportation and storage • -40 to +100 ℃ SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 365 ISO transponder 8.26 MDS D524 6GT2600-5AC00 Degree of protection to EN 60529 • IP67 • IPx9K Shock-resistant to EN 60721-3-7 class 7M3 100 g 1) Vibration-resistant to EN 60721-3-7, class 7M3 20 g 1) Torsion and bending load Not permitted Design, dimensions and weight 8.26.5 Dimensions (Ø x H) 27 x 4 mm Weight 5g Type of mounting • Glued • 1 x M3 screw 2) ≤ 1 Nm 1) The values for shock and vibration are maximum values and must not be applied continuously. ) To prevent it loosening during operation, secure the screw with screw locking varnish. Dimension drawing Figure 8-72 Dimensional drawing of MDS D524 All dimensions in mm SIMATIC RF300 366 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.27 MDS D525 8.27 MDS D525 8.27.1 Characteristics MDS D525 Characteristics Area of application Compact and rugged ISO transponder; suitable for screw mounting Use in assembly and production lines in the powertrain sector; ideal for mounting on motors, gearboxes, and workpiece holders Rugged packaging of the MDS D525; can therefore also be used under extreme environmental conditions without problems 8.27.2 Memory size 8192 bytes of FRAM user memory Write/read range See section "Field data of ISO transponders (MDS D) (Page 52)". Mounting on metal Yes ISO standard ISO 15693 Degree of protection IP68/IPx9K Ordering data Table 8- 66 Ordering data for MDS D525 Article number MDS D525 6GT2600-5AG00 SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 367 ISO transponder 8.27 MDS D525 8.27.3 Application example Figure 8-73 8.27.4 Application example Technical specifications Table 8- 67 Technical specifications for MDS D525 6GT2600-5AG00 Product type designation SIMATIC MDS D525 Memory Memory configuration • UID • 8 bytes • User memory • 8192 bytes FRAM • OPT memory • 16 bytes FRAM Read cycles (at < 40 ℃) > 1012 Write cycles (at < 40 ℃) > 1012 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data of ISO transponders (MDS D) (Page 52)" MTBF (Mean Time Between Failures) 228 years SIMATIC RF300 368 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.27 MDS D525 6GT2600-5AG00 Mechanical specifications Housing • Material • Plastic PA 6.6 GF • Color • Black Recommended distance to metal > 0 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • During operation • -25 to +85 ℃ • During transportation and storage • -40 to +125 ℃ • IP68 2 hours, 2 bar, +20 °C • IPx9K steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75 °C Degree of protection to EN 60529 Shock-resistant to IEC 68-2-27 50 g 1) Vibration-resistant to IEC 68-2-6 20 g 1) Torsion and bending load Not permitted Design, dimensions and weight Dimensions (Ø x H) 24 x 10 mm (without set screw) Weight 35 g Type of mounting 1x transponder set screw M6 SW 22; ≤ 6 Nm 1) The values for shock and vibration are maximum values and must not be applied continuously. SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 369 ISO transponder 8.27 MDS D525 8.27.5 Dimension drawing Figure 8-74 Dimensional drawing of MDS D525 All dimensions in mm SIMATIC RF300 370 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.28 MDS D526 8.28 MDS D526 8.28.1 Characteristics MDS D526 8.28.2 Characteristics Area of application Compact and rugged ISO transponder; suitable for identification of transport units in production-related logistics; can also be deployed in harsh conditions Memory size 8192 bytes of FRAM user memory Write/read range See section "Field data of ISO transponders (MDS D) (Page 52)." Mounting on metal Yes, with spacer ISO standard ISO 15693 Degree of protection IP68 Ordering data Table 8- 68 Ordering data for MDS D526 Article number MDS D526 Table 8- 69 6GT2600-5AH00 Ordering data for MDS D526 accessories Article number Spacer 6GT2690-0AL00 SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 371 ISO transponder 8.28 MDS D526 8.28.3 Mounting on metal Mounting on metal ≥ 25 mm Figure 8-75 Mounting the MDS D126 / D426 / D526 on metal with spacer Flush-mounted in metal ≥ 25 mm ≥ 50 mm Figure 8-76 Flush installation of the MDS D126 / D426 / D526 in metal with spacer SIMATIC RF300 372 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.28 MDS D526 8.28.4 Technical specifications Table 8- 70 Technical specifications for MDS D526 6GT2600-5AH00 Product type designation SIMATIC MDS D526 Memory Memory configuration • UID • 8 bytes • User memory • 8192 bytes FRAM • OTP • ??? Read cycles (at < 40 ℃) > 1012 Write cycles (at < 40 ℃) > 1012 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data of ISO transponders (MDS D) (Page 52)" MTBF (Mean Time Between Failures) 228 years Mechanical specifications Housing • Material • Plastic PA 6.6 GF • Color • Black Recommended distance to metal ≥ 25 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • During operation • -25 to +85 ℃ • During transportation and storage • -40 to +100 ℃ Degree of protection to EN 60529 IP68 2 hours, 2 bar, +20 °C Shock-resistant to IEC 68-2-27 50 g 1) Vibration-resistant to IEC 68-2-6 20 g 1) Torsion and bending load Not permitted SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 373 ISO transponder 8.28 MDS D526 6GT2600-5AH00 Design, dimensions and weight 8.28.5 Dimensions (Ø x H) 50 x 3.6 mm Weight 13 g Type of mounting 1 x M4 screw 2) ≤ 1 Nm 1) The values for shock and vibration are maximum values and must not be applied continuously. ) To prevent it loosening during operation, secure the screw with screw locking varnish. Dimension drawing Figure 8-77 Dimensional drawing of MDS D526 All dimensions in mm SIMATIC RF300 374 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.29 MDS D528 8.29 MDS D528 8.29.1 Characteristics MDS D528 Characteristics Area of application Compact and rugged ISO transponder; suitable for screw mounting Use in assembly and production lines in the powertrain sector The rugged housing of the MDS D528 means that it can also be used in extreme environmental conditions without problems. 8.29.2 Memory size 8192 bytes of FRAM user memory Write/read range See section "Field data of ISO transponders (MDS D) (Page 52)" Mounting on metal Yes ISO standard ISO 15693 Degree of protection IP68/IPx9K Ordering data Table 8- 71 Ordering data for MDS D528 Article number MDS D528 6GT2600-5AK00 SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 375 ISO transponder 8.29 MDS D528 8.29.3 Application example Figure 8-78 8.29.4 Application example Technical specifications Table 8- 72 Technical specifications for MDS D528 6GT2600-5AK00 Product type designation SIMATIC MDS D528 Memory Memory configuration • UID • 8 bytes • User memory • 8192 bytes FRAM • OTP • ??? Read cycles (at < 40 ℃) > 1012 Write cycles (at < 40 ℃) > 1012 Data retention time (at < 40 ℃) > 10 years Write/read distance (Sg) Dependent on the reader used, see section "Field data of ISO transponders (MDS D) (Page 52)" MTBF (Mean Time Between Failures) 228 years SIMATIC RF300 376 System Manual, 07/2016, C79000-G8976-C345-0x ISO transponder 8.29 MDS D528 6GT2600-5AK00 Mechanical specifications Housing • Material • Plastic PA 6.6 GF • Color • Black Recommended distance to metal ≥ 0 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • During operation • -25 to +85 ℃ • During transportation and storage • -40 to +125 ℃ • IP68 2 hours, 2 bar, +20 °C • IPx9K steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75 °C Degree of protection to EN 60529 Shock-resistant to IEC 68-2-27 50 g 1) Vibration-resistant to IEC 68-2-6 20 g 1) Torsion and bending load Not permitted Design, dimensions and weight Dimensions (Ø x H) 24 x 20 mm (without set screw) Weight 35 g Type of mounting 1x transponder set screw M8 SW 22; ≤ 8 Nm 1) The values for shock and vibration are maximum values and must not be applied continuously. SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 377 ISO transponder 8.29 MDS D528 8.29.5 Dimension drawing Figure 8-79 Dimensional drawing of MDS D528 All dimensions in mm SIMATIC RF300 378 System Manual, 07/2016, C79000-G8976-C345-0x System integration The communication modules (interface modules) are links between the RFID components (reader and transponder) and the higher-level controllers (e.g. SIMATIC S7), or PCs or computers. 9.1 Introduction The readers are connected to the controller via the following interface or communications modules: ● ASM 456 ● ASM 475 ● SIMATIC RF120C ● SIMATIC RF160C ● SIMATIC RF170C ● SIMATIC RF180C ● SIMATIC RF182C ● RFID 181EIP Function blocks, interface modules/communication modules and readers Function blocks are used for integration into the SIMATIC. You will find information on the following blocks on the Internet in "Industry Online Support (https://support.industry.siemens.com/cs/ww/en/ps/14971)". ● Ident profile and Ident blocks, standard function for RFID systems The Ident library linked into the TIA Portal as of STEP 7 Basic / Professional V14 SP 1 ● RFID standard profile; standard functions for RFID systems ● FB 45 for MOBY U, MOBY D, RF200, RF300 ● FB 55 ● RF160C communications module with FC 44 SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 379 System integration 9.1 Introduction Interface modules/communication modules and function blocks The following table shows the most important characteristics of the interface modules/communications modules. Table 9- 1 Overview of interface modules/communication modules ASM/ Interfaces to the Interfaces to the communications application reader module (PLC) Reader connections Dimensions (W x H x D) Temperature Degree of range protection ASM 456 PROFIBUS DP- 2 x 8-pin connector V1 socket, M12 2 (parallel) 60 x 210 x 54 0 ℃ to +55 ℃ IP67 ASM 475 S7-300 (central), ET200M (PROFIBUS) Via screw terminals in front connector 40 x 125 x 120 mm 0 ℃ to +60 ℃ IP20 SIMATIC RF120C S7-1200 (central) 9-pin D-sub socket 30 x 100 x 75 mm 0 ℃ to +55 ℃ IP20 SIMATIC RF160C PROFIBUS DP / DP-V0 2 x 8-pin connector socket, M12 2 (parallel) 60 x 210 x 30 mm 0 ℃ to +55 ℃ IP67 SIMATIC RF170C PROFIBUS DP- 2 x 8-pin connector V1 socket, M12 2 (parallel) 90 x 130 x 60 mm -25 °C to +55 °C IP67 or 79 mm PROFINET IO SIMATIC RF180C PROFINET IO 2 x 8-pin connector socket, M12 2 (parallel) 60 x 210 x 54 mm 0 °C to +60° C IP67 SIMATIC RF182C TCP/IP 2 x 8-pin connector socket, M12 2 (parallel) 60 x 210 x 30 mm 0 ℃ to +60 ℃ IP67 RFID 181EIP Ethernet IP 2 x 8-pin connector socket, M12 2 (parallel) 60 x 210 x 54 mm 0 °C to +60° C IP67 The following table shows the program blocks compatible with the interface modules/communications modules. SIMATIC RF300 380 System Manual, 07/2016, C79000-G8976-C345-0x System integration 9.1 Introduction Table 9- 2 Compatible program blocks ASM/ communications module Compatible program blocks in conjunction with ... S7-300 / S7-400 and STEP 7 Classic V5.5 S7-300 / S7-400 and STEP 7 Basic/Professional S7-1200 / S7-1500 and STEP 7 Basic/Professional ASM 456 FB 45 FB 45 Ident profile FB 55 FB 55 Ident blocks Standard profile V1.19 Ident profile PIB_1200_UID_001KB Ident profile ASM 475 SIMATIC RF120C PIB_1200_UID_032KB FB 45 FB 45 FB 55 FB 55 -- -- -Ident profile Ident blocks PIB_1200_UID_001KB PIB_1200_UID_032KB SIMATIC RF160C SIMATIC RF170C SIMATIC RF180C FC 44 FC 44 Application blocks for RF160C Application blocks for RF160C FB 45 FB 45 FB 55 FB 55 FB 45 FB 45 Ident profile FB 55 FB 55 Ident blocks Standard profile V1.19 Ident profile PIB_1200_UID_001KB Ident profile Application blocks for RF160C -- PIB_1200_UID_032KB SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 381 System integration 9.2 ASM 456 9.2 ASM 456 Configured with ASM 456 Figure 9-1 Configuration of ASM 456 For more detailed information, please refer to ASM 456 Operating Instructions (https://support.industry.siemens.com/cs/ww/en/view/32629442). 9.3 ASM 475 9.3.1 Features Area of application The ASM 475 interface module acting as the link between all RF300 systems and SIMATIC S7-300 performs the functions of a communication module. It can be operated centrally in the S7-300 or decentrally in an ET200M. As many as eight ASM 475 interface modules can be plugged into one SIMATIC S7-300 rack and operated. In a configuration with several racks (max. four), the ASM 475 can be plugged into and operated on any rack. This means that as many as 32 ASMs can be operated in the maximum configuration of a SIMATIC S7-300. The ASM can also be operated in the ET 200M distributed I/O on PROFIBUS. Operation in an S7-400 environment is therefore problem-free. Up to 7 ASMs can be operated on each ET 200M. Error messages and operating statuses are indicated by LEDs. Since there is electrical isolation between the read/write device and the SIMATIC S7-300 bus, a configuration that is immune to interference is possible. SIMATIC RF300 382 System Manual, 07/2016, C79000-G8976-C345-0x System integration 9.3 ASM 475 Figure 9-2 Interface module ASM 475 The ASM 475 with the article number 6GT2002-0GA10 is a module that can be set in the parameters. The basic functions of the module are then already specified when the module is configured in HW Config (e.g. standard addressing). The data in the MDS is accessed direct by means of physical addresses using the ASM 475. Operation in a SIMATIC S7 is controlled by the function block FB 45. ASM 475 and FB 45 form a unit that is used for reading the data of the MDS simply and at optimal speed. 9.3.2 Ordering data Table 9- 3 Ordering data for ASM 475 Article number ASM 475 interface module for SIMATIC S7 2 x RF3xxR reader with RS-422 can be connected in parallel, without front connector Table 9- 4 6GT2002-0GA10 Ordering data for ASM 475 accessories Article number Front connector (1 x per ASM) 6ES7392-1AJ00-0AA0 Connecting cable ASM 475 ↔ RF3xxR Plug-in cable, pre-assembled, length: 2 m (standard length) 6GT2891-0EH20 Plug-in cable, pre-assembled, length: 5 m 6GT2891-0EH50 Terminal element (1 x per reader cable) 6ES7390-5BA00-0AA0 Shield connecting element 6ES7390-5AA00-0AA0 The plug-in cables 6GT2891-4Fxx can be used as extension cables. SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 383 System integration 9.3 ASM 475 9.3.3 Indicators Bezel and indicator elements The figure below illustrates the bezel of the ASM 475 and the inside of the front door complete with the associated connection diagram. The read/write devices must be connected to the ASM in accordance with the connection diagram. Figure 9-3 Bezel and inside of the front door of the ASM 475 SIMATIC RF300 384 System Manual, 07/2016, C79000-G8976-C345-0x System integration 9.3 ASM 475 Display elements on the ASM Table 9- 5 Function of the LEDs on the ASM 475 Light emitting diode Meaning SF System fault (hardware error on ASM) DC 5V 24 V are connected to ASM and the 5 V voltage on ASM is OK. ACT_1, ACT_2 The corresponding reader is active in processing a user command. ERR_1, ERR_2 A flashing pattern indicates the last error to occur. This display can be reset using the parameter Option 1. PRE_1, PRE_2 Indicates the presence of a transponder. RxD_1, RxD_2 Indicates live communication with the reader. In the event of a fault on the reader, this display may also be lit. On the ASM 475, further operating states are indicated with the LEDs PRE, ERR and SF: Table 9- 6 Operating status display on ASM 475 via LEDs SF PRE_1 ON OFF/ON ON (perm.) OFF/ON ON (perm.) Hardware is defective (RAM, Flash, etc.) ON OFF ON OFF OFF Charger is defective (can only be repaired in the factory). OFF 2 Hz OFF 2 Hz OFF Firmware loading is active or no firmware detected OFF 2 Hz Any value 5 Hz OFF OFF ERR_1 2 Hz 5 Hz PRE_2 2 Hz 5 Hz ERR_2 2 Hz 5 Hz Meaning • Firmware download • ASM must not be switched off Firmware loading terminated with errors • Restart required • Load firmware again • Check update files Operating system error • 1 flash every 2 s OFF 1 flash every 2 s Switch ASM off/on ASM has booted and is waiting for a RESET (init_run) from the user. SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 385 System integration 9.3 ASM 475 9.3.4 Configuration Centralized configuration with SIMATIC S7-300 Figure 9-4 Configuration of ASM 475 central Distributed configuration with ET200M Figure 9-5 Configuration of ASM 475 distributed Reader connection system You will find more information on the reader connector technology in the section "Reader RF3xxR (RS422) with ASM 475 (Page 419)". SIMATIC RF300 386 System Manual, 07/2016, C79000-G8976-C345-0x System integration 9.3 ASM 475 Cable installation Signal Pin on M12 connector Cable Labeling 24 VDC white 1 Reader 2 TX - brown 1 Reader 2 GND Green 1 Reader 2 TX + Yellow 1 Reader 2 8 -16 7-15 9-17 6-14 RX + Gray 1 Reader 2 4-12 RX - Pink 1 Reader 2 5-13 Shield 8+ Cable assignment for connection of an RF300 reader to ASM 475 SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 387 System integration 9.3 ASM 475 9.3.5 Shield connection When the reader is connected to the ASM 475, the cable shield must be connected to a shield terminal. Shield terminals and holding clips are standard components of the product spectrum of S7-300. ① ② ③ ④ Holding bracket Cable to 2nd reader Cable to 1st reader Shield terminal Figure 9-6 Shield terminal ASM 475 SIMATIC RF300 388 System Manual, 07/2016, C79000-G8976-C345-0x System integration 9.3 ASM 475 9.3.6 Technical data Table 9- 7 Technical specifications for ASM 475 6GT2002-0GA10 Product type designation ASM 475 communications module Interfaces Design of the interface point-to-point link RS-422 Number of connectable readers Electrical connector design • Backplane bus • S7-300 backplane bus • PROFIBUS interface • (according to the head module) • Industrial Ethernet interface • (according to the head module) • Supply voltage • Screw-type or spring-loaded terminals Design of the interface to the reader for communication Screw-type or spring-loaded terminals Mechanical specifications Housing • Material • Noryl • Color • Anthracite Supply voltage, current consumption, power loss Supply voltage 24 VDC Typical current consumption • Without connected devices • 0.1 A • Including connected devices • 1.0 A Power dissipation of the module, typ. 2 Watts Current consumption from I/O bus, max. 80 mA Electrical isolation between S7-300 and RF300 Yes Fuse 24 V for the reader Yes, electronic SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 389 System integration 9.3 ASM 475 6GT2002-0GA10 Permitted ambient conditions Ambient temperature • During operation (horizontal installation) 0 ... +60 ℃ • During operation (vertical installation) 0 ... +40 ℃ • During transportation and storage -40 ... +70 ℃ Degree of protection IP20 Shock-resistant to IEC 61131-2 150 m/s2 Vibration-resistant to IEC 61131-2 10 m/s2 Design, dimensions and weight Dimensions (L x W x H) 120 x 40 x 125 mm Weight 0.2 kg Type of mounting S7-300 rack Cable length for RS-422 interface, maximum 1000 m Product properties, functions, components general LED display design • 4 LEDs per reader connector • 2 LEDs for device status Product function transponder file handler addressable Yes Protocol supported S7 communication Yes Product functions management, configuration, engineering Type of parameter assignment Object manager, GSD Type of programming FB 45, FB 55, FC 56 (FC 45/55 with restricted functionality) Type of computer-based communication 2 words cyclic, 238 bytes acyclic Transponder addressing Direct access via addresses Commands Initialize transponder, read data from transponder, write data to transponder Standards, specifications, approvals Proof of suitability CE, FCC, UL/CSA SIMATIC RF300 390 System Manual, 07/2016, C79000-G8976-C345-0x System integration 9.4 RF120C 9.4 RF120C Configuration with RF120C Figure 9-7 Configuration RF120C For more detailed information, refer to the section " RF120C communications module (https://support.industry.siemens.com/cs/ww/en/view/77485950)". 9.5 RF160C Configuration with RF160C Figure 9-8 Configuration RF160C For more detailed information, refer to Operating Instructions RF160C (https://support.industry.siemens.com/cs/ww/en/view/42788808). SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 391 System integration 9.6 RF170C 9.6 RF170C Configuration with RF170C Figure 9-9 Configuration RF170C For more detailed information, please refer to SIMATIC RF170C Operating Instructions (https://support.industry.siemens.com/cs/ww/en/view/32622825). SIMATIC RF300 392 System Manual, 07/2016, C79000-G8976-C345-0x System integration 9.7 RF180C 9.7 RF180C Configured with RF180C Figure 9-10 Configuration of RF180C For more detailed information, refer to SIMATIC RF180C Operating Instructions (https://support.industry.siemens.com/cs/ww/en/view/30012157). SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 393 System integration 9.8 RF182C 9.8 RF182C Configuration with RF182C Figure 9-11 Configuration with RF182C For more detailed information, refer to SIMATIC RF182C Operating Instructions (https://support.industry.siemens.com/cs/ww/en/view/38507897). SIMATIC RF300 394 System Manual, 07/2016, C79000-G8976-C345-0x System diagnostics 10.1 10 Error codes Error codes of the RF300 readers Note Validity of the error codes The following error codes apply only to RF300 readers with an RS-422 interface (except for Scanmode). You can identify the error code in different ways: ● Directly on the reader/interface module by counting the flashing pattern of the red error LED ● In the Ident profile with the output variable "Status" ● with FB 45 / FB 55 variable "error_MOBY". SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 395 System diagnostics 10.1 Error codes Table 10- 1 Error codes of the readers Flashing of the Error code red (hexaLED operating decimal) display on the reader Description 00 00 No error 02 01 Presence error; possible causes: 05 05 • The active command was not carried out completely • The transponder left the antenna field while the command was being processed • Communication problem between reader and transponder Parameter assignment error, possible causes: • Unknown command • Incorrect parameter • Function not allowed 06 06 Air interface faulty 11 0B The MDS E transponder could not be successfully authenticated. 12 0C The transponder memory cannot be written, possible causes: • Hardware fault (memory faulty) • Memory write-protected (corresponding OTP area has already been written) 13 0D Error in the specified memory address (access attempted to nonexistent or non-accessible memory areas). 19 13 Buffer overflow: Insufficient buffer available in the reader for saving the command 20 14 Major system fault (hardware fault) 21 15 Parameter assignment error: bad parameter in RESET command 24 18 Command was sent to a reader that has not yet been initialized 25 19 Previous command is still active 28 1C Antenna is not identified Possible causes: • Antenna is not connected. • Antenna cable is defective. 30 1E Incorrect number of characters in frame 31 1F Running command cancelled by "RESET" command SIMATIC RF300 396 System Manual, 07/2016, C79000-G8976-C345-0x System diagnostics 10.2 Diagnostics functions - STEP 7 Classic 10.2 Diagnostics functions - STEP 7 Classic 10.2.1 Overview Extended diagnostic functions with SIMATIC RF300 With SIMATIC RF300, extended diagnostics functions are available which simplify commissioning and maintenance. This diagnostics data is accessed using the SIMATIC function blocks via the SLG Status and MDS Status commands. These two commands can each be called in various modes (subcommands) for which corresponding data structures (UDTs) are defined. Table 10- 2 In RF300 mode Command Mode Meaning (subcommand) SLG-STATUS 01 Hardware and firmware configuration, parameterization status 06 Communication error counter, current command status MDS-STATUS 01 Serial number of the transponder (UID), memory configuration. EEPROM write-protection status 02 Serial number of the transponder (UID), HF field strength value, communication error counter, presence counter (duration) Overview of the diagnostic functions Table 10- 3 In ISO mode Command Mode Meaning (subcommand) SLG-STATUS 01 Hardware and firmware configuration, parameterization status MDS-STATUS 03 Serial number of the transponder (UID), recognized transponder type number in the field (number = tag - type, see reset parameter "ftim"), memory configuration, write protect status (OTP), size and number of blocks in the user memory SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 397 System diagnostics 10.2 Diagnostics functions - STEP 7 Classic 10.2.2 Reader diagnostics with SLG STATUS The SLG STATUS command can be used to scan the status and diagnostics data of the reader. SLG STATUS (mode 01), corresponds to UDT 110 Name Type Possible Hex values Comment hardware char (31 … 38) Type of hardware hardware_version word loader_version HW version 0 ... FF = Version (high byte): Unused 0 ... FF = Version (low byte) word firmware char firmware_version word driver char driver_version word Version of loader 0 ... FF = Version (high byte) 0 ... FF = Version (low byte) 0 ... FF Type of firmware Firmware version 0 ... FF = Version (high byte) 0 ... FF = Version (low byte) Type of driver 31 interface baud distance_limiting_SLG Version of driver 0 ... FF = Version (high byte) 0 ... FF = Version (low byte) byte Interface type 01 = RS422 02 = RS232 (only RF380R) byte byte 3964R Transmission speed 01 = 19.2 Kbaud 03 = 57.6 Kbaud 05 = 115,2 Kbaud This variable is only provided for the RF380R. Users are therefore able to check the output power actually set. An incorrect value in the parameter "distance_limiting" of the RESET message frame results in the default setting "05". Transmit power 02 0.5 W 03 0.75 W 04 1.0 05 1.25 W (default) 06 1.5 W 07 1.75 W 08 2.0 W SIMATIC RF300 398 System Manual, 07/2016, C79000-G8976-C345-0x System diagnostics 10.2 Diagnostics functions - STEP 7 Classic Name Type multitag_SLG byte field_ON_time_SLG status_ant MDS_control byte Possible Hex values Comment Number of transponders (Multi/Pulk) that can be processed in the antenna field 01 = Single tag mode 00 = RF300 transponder 01 = ISO transponder (non-specific) 03 = ISO transponder (Infineon, MDS D300) 04 = ISO transponder (Fujitsu, MDS D400) 05 = ISO transponder (NXP, MDS D100) 06 = ISO transponder (Texas Instruments, MDS D200) 07 = ISO transponder (ST, LRI2K) 08 = ISO transponder (Fujitsu, MDS D500) 0E = ISO (setting with "scanning_time" and "fcon") 10 = RF300 transponder 20 = MDS E transponder 31 = General Mode FF = Setting with "scanning_time" and "fcon" byte Status of the antenna 01 = Antenna On 02 = Antenna Off byte Presence mode 00 = Operation without presence message 01 = Operation with presence message 04 = Operation with presence message (antenna is off. The antenna is turned on only when a Read or Write command is sent.) SLG STATUS (mode 06), corresponds to UDT 280 Name Type Possible Hex values Comment FZP byte 0 ... FF = Error counter, passive (errors during idle time) ABZ = Abort counter CFZ = Code error counter SFZ = Signature error counter CRCFZ = CRC error counter BSTAT = Current command status ASMFZ = Interface problems to host (ASM/PC) parity, BCC, frame error SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 399 System diagnostics 10.2 Diagnostics functions - STEP 7 Classic Note Counter values are deleted. All counter values are deleted after reading out (= execute "SLG STATUS" command). Explanations: ● "FZP": counts interference pulses when communication with a transponder is not taking place (e.g. electromagnetic interference caused by contactors, motors, etc.). Counter values can, however, also be generated when a transponder is located at the edge of the field even when there is no external interference. ● "ABZ", "CFZ", "SFZ" and "CRCFZ" are counters for protocol errors which may occur during reader-transponder communication. This can be caused by unsuitable reader/transponder positioning (e.g. transponder on field boundary, several transponders in the antenna field) or external EMC interference. To ensure clear diagnosis of the quality of communication, it is recommended that an SLG STATUS command (mode 06) is executed following receipt of the presence command to reset the error counter. The protocol error counters are not mutually independent. If a code error (CFZ) occurs, this will cause a signature (SFZ) or CRC- (CRCFZ) error. ● "BSTAT" is the status for the most recently executed command. A value other than 0 means that the previous command was repeated by the reader due to faults (see above). ● "ASMFZ" signals line-conducted communication interference between the communications module and the reader. Faults of this type can be caused by contact problems on the connector or the cable connection. SIMATIC RF300 400 System Manual, 07/2016, C79000-G8976-C345-0x System diagnostics 10.2 Diagnostics functions - STEP 7 Classic 10.2.3 Transponder diagnostics with MDS STATUS The MDS STATUS command can be used to scan the status and diagnostics data of the transponder that is located within the antenna field. MDS STATUS (mode 1), corresponds to UDT 260 (only for RF300 transponders) Name Type UID array[1…8] byte Possible Hex values Unique identifier 000000005555555 ... 00000000FFFFFFFF MDS_type Lock_state byte byte Comment = b0-31: 4 byte TAG ID, b32-63: 0 Transponder memory configuration 01 = Transponder without FRAM 02 = Transponder with FRAM 8 KB 03 = Transponder with FRAM 32 KB 04 = Transponder with FRAM 64 KB 0 ... FF EEPROM write protection status MDS STATUS (mode 02), corresponds to UDT 270, only for RF300 transponders Name Type UID array[1…8] byte Possible Hex values Comment Unique identifier 0000000055555555 ... 00000000FFFFFFFF = b0-31: 4 byte TAG ID, b32-63: 0 LFD byte 0 ... FF = Value for field strength determined in the transponder FZP byte 0 ... FF = Error counter (passive) ➙ errors during idle time FZA byte 0 ... FF = Error counter (active) ANWZ byte 0 ... FF = Presence counter SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 401 System diagnostics 10.2 Diagnostics functions - STEP 7 Classic Note Counter values are deleted. All counter values are deleted when the transponder exits the antenna field or when the antenna is switched off. Explanations: ● "LFD" is a measured value for the field strength that is determined in the transponder. The lower the value, the higher the field strength. ● "FZP" counts interference pulses when communication with a transponder is not taking place (e.g. electromagnetic interference caused by contactors, motors, etc.). Counter values can also be generated when a transponder is located at the edge of the field even when there is no external interference. ● "FZA" counts errors that can occur during reader-to-transponder communication. This can be caused by unsuitable reader/transponder positioning (e.g. transponder on field boundary, several data carriers in the field) or external electromagnetic interference. ● "ANWZ" is the value for the time that the transponder remains in the field before the MDS STATUS command (mode 02) is executed. A time step is 10 ms. The maximum time that can be recorded is therefore 2.5 s. MDS STATUS (mode 03), corresponds to UDT 230 Name Type UID array[1…8] byte Possible Values Comment Unique identifier 0000000000000000 ... =8 byte UID, MSB first FFFFFFFFFFFFFFFF MDS_type byte Transponder type (vendor, identification) 00 = ISO transponder (non-specific) 03 = ISO transponder (Infineon, MDS D300) 04 = ISO transponder (Fujitsu, MDS D400) 05 = ISO transponder (Philips, MDS D100) 06 = ISO transponder (Texas Instruments, MDS D200) 07 = ISO transponder (ST, LRI2K) 08 = ISO transponder (Fujitsu, MDS D500) 11 = RF300 transponder (0 kB) 12 = RF300 transponder (8 kB) 13 = RF300 transponder (32 kB) 14 = RF300 transponder (64 kB) 15 = RF300 transponder (128 kB) 16 = RF300 transponder (256 kB) 21 = ISO transponder (NXP, 1 kB, MDS E) 22 = ISO transponder (Infineon, 1 kB, MDS E) 23 = ISO transponder (NXP, 4 kB) SIMATIC RF300 402 System Manual, 07/2016, C79000-G8976-C345-0x System diagnostics 10.3 Diagnostics functions STEP 7 Basic / Professional Name Type Possible Values Comment binary 0 ... 255 Vendor-specific value IC_version byte 0 ... FF Chip version size byte 0 ... FF Memory size in bytes lock_state byte 0 ... FF Lock state, OTP information: One bit is used per block (4 x 4 bytes or 2 x 8 bytes) (bit = 1: block is locked) Depending on transponder type, e.g. my-d: 992 bytes Example: 01 = Block 1 of address FF80 ... FF83 is locked or 03 = Block 1 and 2 of address FF80 ... FF87 are locked, e.g. for the Philips SL2 ICS20 (MDS D124, D160 or D100). This chip provides a usable memory with 112 bytes EEPROM from address 0000 - 006F (total OTP area "0060 ... 006F"). In this memory, the locked area corresponds to the addresses 0060 ... 0063 or 0060 ... 0067 block_size byte 0 ... FF Block size of the transponder nr_of_blocks byte 0 ... FF Number of blocks Depending on transponder type, e.g. my-d: 4 bytes Depending on transponder type, e.g. my-d: 248 bytes 10.3 Diagnostics functions STEP 7 Basic / Professional Extensive diagnostics functions for the SIMATIC RF300 readers with STEP 7 Basic / Professional are being planned. With the aid of the Ident profile and the Ident blocks, you can make different diagnostics queries. SIMATIC RF300 System Manual, 07/2016, C79000-G8976-C345-0x 403 System diagnostics 10.3 Diagnostics functions STEP 7 Basic / Professional SIMATIC RF300 404 System Manual, 07/2016, C79000-G8976-C345-0x
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : SIEMENS AG Create Date : 2016:07:12 09:45:24+02:00 Keywords : Draft, Document!, Note:, This, document, is, a, draft, document., This, document, is, not, released, for, publication., Siemens, accepts, no, liability, for, the, completeness, and, correctness, of, the, contents. Modify Date : 2016:08:01 11:59:14+02:00 Has XFA : No Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Metadata Date : 2016:08:01 11:59:14+02:00 Creator Tool : Acrobat PDFMaker 11 für Word Document ID : uuid:b70fa864-d883-4fd1-bf2f-f4a77846d359 Instance ID : uuid:f0e17516-8492-428d-a78f-814bb6010806 Format : application/pdf Title : SIMATIC RF300 Description : SIMATIC Ident Creator : SIEMENS AG Subject : Draft Document!, Note: This document is a draft document. This document is not released for publication. Siemens accepts no liability for the completeness and correctness of the contents. Producer : Adobe PDF Library 11.0 Source Modified : D:20160712074354 Company : Siemens AG Comments : Edition : 0.00347222222222222 System : SIMATIC Ident Print-year : 2005 - 2016 Document-class : System Manual Document-class-mrl : Product-group : RFID systems Order-nr : C79000-G8976-C345-0x Ident-nr : Company-short : Siemens Company-long : Siemens AG Headline : System Manual Page Layout : OneColumn Page Mode : UseOutlines Page Count : 212EXIF Metadata provided by EXIF.tools