Siemens 110 Users Manual RDG100 140 160 Operating Instructions
140 1801_a6v10355400[1]
160 to the manual a8674e13-cd7d-4c73-b0d8-e5a2505c497a
2015-02-05
: Siemens Siemens-110-Users-Manual-410622 siemens-110-users-manual-410622 siemens pdf
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
s Operating Instructions RDG100/110/140/160 RDG – the electronic room thermostat that allows you to set the ideal room temperature you want. The thermostat satisfies your individual needs in all operating modes: Comfort, Economy and Protection. The fan operates either in Automatic mode or at the selected speed when using Manual mode. You can either rely on the factory settings or make adjustments that suit your individual needs. Main display Operating mode Room temperature Room temperature in degrees Celsius Room temperature in degrees Fahrenheit Button lock active Heating mode Electric heater on Cooling mode Comfort Alert indicator Economy Protection mode: Protection against frost Indicator for selecting mode Condensation in the room Temporary timer function active Additional user information Operating mode button Fan mode Fan mode button Automatic Rotary knob Manual: Low / medium / high Changing the room temperature The room temperature setpoint can be adjusted with the rotary knob when is active Comfort mode Turn the rotary knob clockwise (+) to increase, or counterclockwise (-) to decrease the current room temperature setpoint for Comfort mode The setting range is from 5...40 °C, unless limited by parameters P09 and P10 (for parameter settings, see reverse side). Adjusting the fan speed Press the fan mode button until the desired fan mode is reached In Automatic mode , the fan speed is automatically selected by the thermostat depending on the setpoint and the actual room temperature. When the room temperature reaches the setpoint, the fan stops (factory setting) or runs at low speed (P15). In Manual mode, the fan operates independently and always runs at the same speed: Low / medium / high Note: If desired, you can change the fan mode selector option via P03: Manually only, or manually including Protection mode. Use P15 to set the fan speed in dead zone. Selecting Comfort mode Press the operating mode button until symbol Comfort mode is selected In Comfort mode, the thermostat maintains the setpoint which can be readjusted with the rotary knob appears, indicating that Selecting Protection mode Press the operating mode button until symbol Protection mode is selected In Protection mode, the plant stops operating. If the room temperature falls below 8 °C, heating is switched on however to protect the room against frost appears, indicating that The setpoints for Protection mode can be changed by your HVAC installer if desired: Changes made by installer: Frost protection: ____________ ˚C Heat protection: ______________˚C Selecting Economy mode In Economy mode, the room temperature is maintained at a lower or higher setpoint, thus saving energy and money. When selecting Economy, make sure that parameter P02 is set to 2 Press the operating mode button until symbol You can change the preselected setpoint by adjusting parameters P11 and P12 (for parameter settings, see reverse side) appears Important: The setpoint for Economy can be set to OFF. This means that the thermostat is deactivated! Risk of frost, i.e. no protective heating or cooling function is provided! Energy saving tips without sacrificing comfort: • Air out rooms for short periods of time only, but properly, with the windows wide open • Never allow the room temperature to exceed 21 °C through heating, and to fall below 25.5 °C through cooling Button lock To lock or unlock the buttons manually, press and hold the fan mode button for 3 seconds. The buttons are locked or unlocked in this manner if P14 is set to 2 If P14 is set to 1, the thermostat automatically locks the buttons 10 seconds after the last adjustment Temporary timer for extended presence or absence The Comfort and Economy modes can be temporarily extended by 0.5 to 9.5 hours using the temporary timer. 1. To set the temporary timer, press and hold the operating mode button for maximum 3 seconds. While holding the button, turn the rotary knob clockwise or counterclockwise as required. a) Turn the rotary knob clockwise to extend Comfort mode. 0....+9:30 Display: b) Turn the rotary knob counterclockwise to extend Economy mode. Display: 0....-9:30 2. Release the operating mode button and the mode is temporarily changed, indicated by . After the temporary timer has elapsed, the thermostat will resume operation in the operating mode that was active before: Extended Comfort mode New operating mode = Economy Extended Economy mode New operating mode = Comfort If Economy cannot be selected via the operating mode button (P02≠2), Protection mode will be used for extended absence instead! The temporary timer function is aborted whenever a new setting is made Note: Extended Comfort mode is also possible when an external contact such as a keycard switch or central time clock is active To enable this function, the time for the extended period must be set via parameter P68. Changing from heating to cooling mode Depending on the type of plant, the changeover from heating to cooling (or vice versa) is made either automatically by a changeover sensor or a remote changeover switch, or manually by pressing the operating mode button (see parameter P01) To select cooling or heating manually (P01=2), press the operating mode button until the desired mode appears With automatic changeover or continuous heating / cooling, symbols indicate that the system currently operates in heating or cooling mode With manual changeover, symbol appears, indicating that the system currently operates in heating or cooling mode / Control parameters If you want to change control parameters, proceed as follows: 1. Press both buttons simultaneously for at least 3 seconds. 2. Release them and, within 2 seconds, press the right button again for 3 seconds. The display shows P01. 3. Select the required parameter by turning the rotary knob. (OK). The current value of the selected parameter starts blinking and can be 4. Press button changed by turning the rotary knob. (OK) to confirm the adjusted value, or (Esc) to cancel the change. 5. Press button (Esc) to leave the If you wish to adjust additional parameters, repeat steps 3 through 5, or press parameter setting mode. Parameter list No. P01 Parameter name Control sequence Default value 2-pipe / 2stage: 1 = cooling only 4-pipe: 4 = H and C 1 Setting range 0 = heating only 1 = cooling only 2 = H/C changeover, manually 3 = H/C changeover, auto 4 = heating and cooling P02 Mode selection via operating mode button P03 Mode selection via fan mode button 0 P04 Selection of °C or °F 0 P05 P06 Sensor calibration Standard temperature display 0.0 K 0 P07 Additional display information 0 P08 P09 21 °C 5 °C 35 °C 5…40 °C 15 °C OFF, 5 °C…WcoolEco 30 °C OFF, WheatEco…40°C P13 Comfort basic setpoint Minimum setpoint limitation in Comfort mode Maximum setpoint limitation in Comfort mode Setpoint for heating in Economy mode (WheatEco) Setpoint for cooling in Economy mode (WcoolEco) Electric heater in cooling mode 1 = Comfort / Protection mode 2 = Comfort / Economy / Protection mode 0 = Auto / Manual 1 = Manual 2 = Auto / Manual / Protection mode 0 = °C 1 = °F – 3…3 K 0 = Room temperature 1 = Setpoint 0 = --- (no display) 1 = ˚C and ˚F 5…40 °C 5…40 °C ON P14 Button lock 0 P15 Fan speed in dead zone (Comfort mode) 0 OFF = Disabled ON = Enabled 0 = Disabled 1 = Automatic 2 = Manual 0 = Disabled 1 = Stage 1 (H or C) 2 = Stage 1 (Cooling only) P10 P11 P12 The control parameters displayed depend on the DIP switch settings made Adj. Siemens Switzerland Ltd Subject to change B3181.1en 21 Oct 2011
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : Karl Wellinger Comments : Company : Siemens Switzerland Ltd, Building Technologies Create Date : 2011:11:06 18:03:41+01:00 Modify Date : 2011:11:06 18:04:54+01:00 Subject : XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Creator Tool : Acrobat PDFMaker 9.1 for Word Metadata Date : 2011:11:06 18:04:54+01:00 Producer : Acrobat Distiller 9.4.2 (Windows) Keywords : Format : application/pdf Creator : Karl Wellinger Title : RDG100-110-140-160 Operating Instructions Description : Document ID : uuid:688825b7-05b9-44fb-8a34-7e2f22766573 Instance ID : uuid:583e44de-e105-40e3-ac16-fdb93c1a548c Page Count : 2EXIF Metadata provided by EXIF.tools