Siemens Network Card 200 Users Manual MultiRanger 100/200
200 to the manual e879afde-8df8-4938-81e8-aafd74db20fd
2015-02-05
: Siemens Siemens-Network-Card-200-Users-Manual-410341 siemens-network-card-200-users-manual-410341 siemens pdf
Open the PDF directly: View PDF
Page Count: 282 [warning: Documents this large are best viewed by clicking the View PDF Link!]
- The MultiRanger 100 and 200
- Specifications
- Installation
- Wiring
- Operating the MultiRanger
- RUN Mode
- Readings in RUN Mode
- Status Parameters
- Controlling the Display
- PROGRAM Mode
- Starting PROGRAM Mode
- Dolphin Plus
- SIMATIC Process Device Manager (PDM)
- Activating the MultiRanger
- Security
- Using Units or Percent (%)
- Parameters Types
- Parameter Reset
- Display Readout
- Primary and Secondary Indexes
- Starting Measurement
- Relays
- Backup Level Override
- Discrete Inputs
- mA I/O
- Volume [MR 200]
- Alarms
- Pump Control
- Setting a Pump Down Group
- Setting a Pump Up (Reservoir) Group
- Other Pump Control Algorithms
- Optional Pump Controls
- Starting Pumps by Rate of Level Change [MR 200]
- Rotating Pumps by Service Ratio [MR 200]
- Totalizing Pumped Volume [MR 200]
- Setting Independent Failsafe Controls
- Setting a Pump to Run On [MR 200]
- Setting the Pump Start Delays [MR 200]
- Reducing Wall Cling [MR 200]
- Grouping Pumps [MR 200]
- Setting a Flush Valve [MR 200]
- Relay Controlled by Communications
- Tracking Pump Usage
- Rake (Screen) Control [MR 200]
- External Totalizers and Flow Samplers [MR 200]
- Open Channel Monitoring (OCM) [MR 200]
- Testing the Configuration
- MultiRanger Communications
- Communications Installation
- Modbus Register Map
- Word Order (R40,062)
- Map ID (R40,063)
- Product ID (R40,064)
- Point Data (R41,010 – R41,031)
- Totalizer (R41,040 – R41,043)
- Input/Output (R41,070 – R41,143)
- Discrete Inputs (R41,070)
- Relay Outputs (R41,080)
- mA Input (R41,090) [MR 200]
- mA Output (R41,110-41,111)
- Pump Control (R41,400 – R41,474)
- Pump ON Setpoint (R41,420 – R41,425)
- Pump OFF Setpoint (R41,430 – R41,435)
- Pumped Volume (R41,440 – R41,443) [MR 200]
- Pump Hours (R41,450 – R41,461)
- Pump Starts (R41,470 – R41,475)
- Parameter Access (R43,998 – R46,999)
- Parameter Indexing
- Reading Parameters
- Writing Parameters
- Format Words (R46,000 to R46,999)
- Data Types
- Error Handling
- Communication Troubleshooting
- Communication Appendix A: Single Parameter Access (SPA)
- Parameter Reference
- MultiRanger 100 and MultiRanger 200
- Helpful Hints
- Index types
- Quick Start (P001 to P007)
- Volume (P050 to P055) [MR 200]
- Display and Reading (P060 to P062)
- Backup Level Override
- Failsafe (P070 to P072)
- Relays (P100 to P119)
- Pump Setpoint Modifiers (P121 and P122) [MR 200]
- Independent Relay Failsafe (P129)
- Advanced Pump Control Modifiers (P130 to P137) [MR 200]
- Flush Systems (P170 to P173) [MR 200]
- mA Output (P200 to P219)
- Independent mA Setpoints (P210 and P211)
- mA Output Limits (P212 and P213)
- mA Output Trim (P214 to P215)
- mA Output Failsafe (P219) [MR 200]
- mA Input (P250 to P260) [MR 200]
- Discrete Input Functions (P270 to P275)
- Standard Data Logging (P300 to P321)
- Record Temperatures (P300 to P303)
- Record Readings (P304 and P305)
- Pump Records (P309 to P312)
- Flow Records (P320 and P321) [MR 200]
- LCD Totalizer (P322 and P323) [MR 200]
- Profile Records (P330 to P337)
- Auto Record ON and OFF Setpoints (P334 to P337)
- Installation Records (P340 to P342)
- Open Channel Monitoring (P600 to P621) [MR 200]
- Pumped Volume Totalizer (P622) [MR 200]
- Totalizer (P630 to P645) [MR 200]
- Range Calibration (P650 to P654)
- Temperature Compensation (P660 to P664)
- Rate (P700 to P708)
- Measurement Verification (P710 to P713)
- Transducer Scanning (P726 to P729)
- Display (P730 to P739)
- SmartLinx Reserved (P750 to P769)
- Communications (P770 to P782)
- SmartLinx Hardware Testing (P790 to P795)
- Echo Processing (P800 to P807)
- Advanced Echo Processing (P815 to P825)
- Advanced TVT Adjustment (P830 to P835)
- Advanced Shot Adjustment (P840 to P852)
- Test (P900 to P913)
- Measurement (P920 to P927)
- Master Reset (P999)
- Appendix A: Index Types
- Appendix B: Technical Reference
- Appendix C: Troubleshooting
- Appendix D: Pump Control Reference
- Pump Control Options
- Pump Control Algorithms
- Fixed Duty Assist (P111 = 50)
- Fixed Duty Backup (P111 = 51) [MR 200]
- Alternate Duty Assist (P111 = 52)
- Alternate Duty Backup (P111 = 53) [MR 200]
- Service Ratio Duty Assist (P111 = 54) [MR 200]
- Service Ratio Duty Backup (P111 = 55) [MR 200]
- First In First Out (FIFO) (P111 = 56) [MR 200]
- Pump by Rate (P121) [MR 200]
- Other Pump Controls [MR 200]
- Appendix E: Updating Software
- Appendix F: Upgrading
- Appendix G: Conduit Entry for Class 1, Div 2 Applications
- Appendix H: Software Revision History
- Programming Charts
- Index