Siemens Sitrans P Users Manual FI01_2009_en_kap02
P to the manual 820c338e-ed89-4382-be5d-db93e3a08f2e
2015-02-05
: Siemens Siemens-Sitrans-P-Users-Manual-410289 siemens-sitrans-p-users-manual-410289 siemens pdf
Open the PDF directly: View PDF .
Page Count: 234
Download | |
Open PDF In Browser | View PDF |
© Siemens AG 2008 SITRANS P measuring instruments for pressure 2/2 Product overview 2/150 2/4 Transmitters for gage, absolute and differential pressure Z series for gage pressure Z series for gage and absolute pressure SITRANS P250 for differential pressure ZD series for gage and absolute pressure 2/150 2/158 2/161 2/170 2/173 2/174 2/176 2/179 2/182 2/187 2/4 2/6 2/12 2/17 2/21 2/21 2/28 2/47 2/47 2/52 2/58 Transmitters for food, pharmaceuticals and biotechnology SITRANS P Compact for gage and absolute pressure SITRANS P300 for gage and absolute pressure Transmitters for gage pressure for paper industry SITRANS P300 and DS III series with PMC connection Technical description Technical specifications, ordering data, dimensional drawings - DS III series with PMC connection - SITRANS P300 with PMC connection 2/190 2/190 2/191 2/193 2/195 2/196 2/197 2/198 2/63 2/63 2/70 2/79 2/89 2/98 2/107 2/124 2/134 2/134 2/136 2/142 2/146 2/146 Transmitters for gage, absolute and differential pressure, flow and level DS III, DS III PA and DS III FF series Technical description Technical specifications, ordering data, dimensional drawings - for gage pressure - for gage and absolute pressure with front-flush diaphragm - for absolute pressure (from gage pressure series) - for absolute pressure (from differential pressure series) - for differential pressure and flow - for level SITRANS P Accessories Supplementary electronics for 4-wire connection Accessories/spare parts for SITRANS P, P300 and DS III series Factory-mounting of valve manifolds on SITRANS P transmitters 2/201 2/204 2/206 2/209 2/212 2/214 2/216 2/220 2/223 2/225 2/226 2/227 2/228 2/229 2/230 2/232 2/233 Remote seals for transmitters and pressure gages Technical description Diaphragm seals of sandwich design Diaphragm seals of flange design Quick-release diaphragm seals Miniature diaphragm seal Flushing rings Clamp-on seals of flange design Quick-release clamp-on seals Remote seals - Measuring setups Questionnaire Fittings Technical description Selection aid Shut-off valves for gage and absolute pressure transmitters Shut-off valves to DIN 16270, DIN 16271 and DIN 16272 Angle adapter Double shut-off valves Accessories for shut-off valves/double shut-off valves 2-way valve manifolds DN 5 Shut-off valves for differential pressure transmitters 2-, 3- and 5-spindle valve manifolds DN 5 Multiway cocks PN 100 3-way and 5-way valve manifolds DN 5 3-way valve manifold DN 8 Valve manifold combination DN 5/DN 8 Valve manifold combination DN 8 2-, 3- and 5-spindle valve manifolds for installing in protective boxes 3- and 5-spindle valve manifolds for vertical angular diff. pressure lines Low-pressure multiway cock Accessories Oval flange Adapters, connection glands Connection parts G½ Water traps, Sealing rings to EN 837-1 Pressure surge reducers Primary shut-off valves Compensation vessels Connection parts Transmitters for hydrostatic level MPS series (submersible sensor) You can download all instructions, catalogs and certificates for SITRANS P free of charge at the following Internet address: www.siemens.com/sitransp Siemens FI 01 · 2009 © Siemens AG 2008 SITRANS P measuring instruments for pressure Product overview ■ Overview Application 2 Description Page Software for Parameterization SITRANS P – measuring instruments for pressure, absolute pressure, differential pressure, flow and level Two- or three-wire transmitters for measuring gage and absolute pressure SITRANS P, Z series Compact single-range transmitters Analog electronics Available ex stock 2/4 – Two- or three-wire transmitters for measuring differential pressure SITRANS P250 Compact single-range transmitters Analog electronics Available ex stock 2/12 – Two- or three-wire transmitters for measuring gage and absolute pressure SITRANS P, ZD series Range adjustment: 5 : 1 Digital display Available ex stock 2/17 – Transmitters for gage and abso- SITRANS P Compact 2/21 lute pressure for food, pharma- Single-range transmitters in 2-wire system ceuticals and biotechnology Hygiene-based design with various aseptic connections according to EHEDG, FDA and GMP recommendations. – Two-wire transmitters for mea- SITRANS P300 2/28 suring gage and absolute pres- • Hygiene-based design according to EHEDG, FDA sure and GMP • Parameterization over 3 buttons or communication over HART, PROFIBUS PA or FOUNDATION Fieldbus • Standard process connection G½, ½-NPT and flush-mounted process connections available • Measuring range adjustment 100 : 1 SIMATIC PDM Two-wire transmitters for measuring gage pressure SITRANS P300 and DS III series with PMC connection for the paper industry • Measuring range adjustment 100 : 1 • Process connections for the paper industry • Parameter assignment over 3 buttons and HART, PROFIBUS PA or FOUNDATION Fieldbus 2/47 SIMATIC PDM Two-wire transmitters for measuring: • Gage pressure, • Absolute pressure • Differential pressure and • Flow or • Level SITRANS P, DS III series 2/63 SITRANS P, DS III PA series SITRANS P, DS III FF series Range adjustment: 100 : 1 Parameterization using: • 3 keys and HART for DS III series • 3 keys and PROFIBUS-PA for DS III PA series • 3 buttons and FOUNDATION Fieldbus for DS III FF series • Available ex stock SIMATIC PDM SIMATIC PDM Supplementary electronics for Output: 0 or 4 to 20 mA adaptation of two-wire transmit- Power supply: 24 V AC/DC, 230 V AC ters for four-wire connections 2/2 Siemens FI 01 · 2009 2/134 – © Siemens AG 2008 SITRANS P measuring instruments for pressure Product overview Application Description Page Software for Parameterization 2-wire transmitter for measuing SITRANS P, MPS series (submersible sensor) 2/146 hydrostatic levels For measuring liquid levels in wells, tanks, channels, dams etc. – Remote seals for measuring viscous, corrosive or fibrous media (as well as media at extreme temperatures) Remote seals in sandwich and flange designs Quick-release remote seals for the food industry Wide range of diaphragm materials and filling liquids available 2/150 – Shutting off the lines for the medium and differential pressure Mounting of transmitter on valve manifold or shut-off fitting Shut-off fittings and valve manifolds available in steel, brass or stainless steel Valve manifolds available for the various process connections of the SITRANS P transmitters 2/190 – 2 Siemens FI 01 · 2009 2/3 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure Z series for gage pressure ■ Overview ■ Design The main components of the pressure transmitter are: • Brass housing with silicon measuring cell and electronics plate • Process connection • Electrical connection 2 The silicon measuring cell has a thin-film strain gage which is mounted on a ceramic diaphragm. The ceramic diaphragm can also be used for aggressive media. The process connection to DIN EN 837-1 is made of brass and has a male thread G½B or a female thread G1/8B. The electrical connection is made using a plug to DIN 43650 with a M16x1.5 cable inlet. ■ Function SITRANS P pressure transmitters, Z series for gage pressure (7MF1562-...) The SITRANS P pressure transmitter, Z series (7MF1562-...), measures the gage pressure of aggressive and non-aggressive gases, liquids and vapors. The pressure transmitters of the Z series for gage pressure measure the pressure of aggressive and non-aggressive gases, liquids and vapors. The measuring cell is temperature-compensated. Mode of operation ■ Benefits • • • • • • High measuring accuracy Sturdy brass housing For aggressive and non-aggressive media For measuring the pressure of liquids, gases and vapor Temperature-compensated measuring cell Compact design ■ Application The pressure transmitter of the Z series for gage pressure (7MF1562-...) is used above all in the following industrial areas: • Power engineering • Mechanical engineering • Shipbuilding • Water supply etc. A concrete application example is the measurement of compressed air containing oil in compressors or compressor stations. 2/4 Siemens FI 01 · 2009 U const. p U I I0, UB SITRANS P pressure transmitters, Z series (7MF1562-...), functional diagram The thin-film measuring cell has a thin-film resistance bridge at which the operating pressure p is transmitted through a ceramic diaphragm. The measuring cell output voltage is fed to an amplifier and converted into an output current of 4 to 20 mA. The output current is linearly proportional to the input pressure. © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure Z series for gage pressure ■ Technical specifications Design SITRANS P pressure transmitter, Z series for gage pressure Wetted parts materials Mode of operation Measuring principle ≈ 0.2 kg (≈ 0.44 lb) Weight Thin-film strain gage Input Measured variable Realtive pressure Measured range 0 to 16 bar g (0 to 232 psi g) or 0 to 25 bar g (0 to 363 psi g) Output • Measuring cell Al2O3 - 96% • Process connection Brass, mat. No. 2.0402 • Gasket Viton Process connection Male thread G½B female thread G1/8B Power supply Current output signal 4 ... 20 mA Terminal voltage on pressure transmitter Measuring accuracy To EN 60770-1 • For current output Error in measurement (at 25 °C (77 °F), including conformity error, hysteresis and repeatability) 0.5% of full-scale value-typical Certificate and approvals Response time T99 < 0.1 s Classification according to pressure equipment directive (DRGL 97/23/EC) 10 to 36 V DC Long-term drift • Start of scale 0.3% of full-scale value/year - typical • Measured span 0.3% of full-scale value/year - typical 2 For gases of fluid group 1 and liquids of fluid 1; complies with requirements of article 3, paragraph 3 (sound engineering practice) ■ Dimensional drawings Influence of ambient temperature • Measured span 0.3%/10 K (0.3%/10 K) of fullscale value - typical -30 ... +120 °C (-22 ... +248 °F) Degree of protection to EN 60529 IP65 Ambient conditions • Ambient temperature -25 ... 85 °C (-13 ... +185 °F) • Storage temperature -50 ... 100 °C (-58 ... +212 °F) G / 8 B Medium conditions *% Rated conditions • Process temperature 0.3%/10 K (0.3%/10 K) of fullscale value - typical ෘ GLDP • Start of scale 6: 0[ SITRANS P pressure transmitters, Z series (7MF1562-...), dimensions in mm (inch) ■ Schematics 1+ Signal 2- + I0 RL UB I0 Output current UB Power supply RL Load Connections: 1 (+UB) 2 (-UB) SITRANS P pressure transmitters, Z series (7MF1562-...), connection diagram ■ Selection and Ordering data Order No. SITRANS P pressure transmitters, Z series for pressure 2-wire system, characteristic rising Measured range 0 ... 16 bar g (0 ... 232 psi g) 0 ... 25 bar g (0 ... 363 psi g) Max. working pressure 32 bar g (464 psi g) 64 bar g (928 psi g) Other version for measuring range ≥ 1 bar g (≥ 14.5 psi g), add Order code and plain text: Measuring range: ... to ... bar g (psi g) Order code D) 7 M F 1 5 6 2 - 7 7 7 0 0 777 3 CB 3 CD 9 AA H1Y D) Subject to export regulations AL: N, ECCN: EAR99H. Siemens FI 01 · 2009 2/5 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure Z series for gage and absolute pressure Measuring range ≥1 bar (≥14.5 psi) ■ Overview Main components: • Stainless steel housing with ceramic measuring cell and electronics module. The temperature-compensated ceramic measuring cell has a thin-film strain gage which is mounted on a ceramic diaphragm. The ceramic diaphragm can also be used for aggressive media. • Process connection made of stainless steel in diverse designs (see Selection and Ordering data) • Electrical connection made using a plug to DIN 43650 with the cable inlet M16 x 1.5, ½-14 NPT or round plug connector M12. 2 The pressure transmitters with a nominal range ≥ 1 bar g (≥ 14.5 psi g) are optionally available with or without explosion protection. ■ Function The pressure transmitter measures the gage and absolute pressure as well as the level of liquids and gases. SITRANS P pressure transmitters, Z series for pressure and absolute pressure (7MF1564-...) Mode of operation SITRANS P pressure transmitters, Z series (7MF1564-...), measure the gage and absolute pressure as well as the level of liquids and gases. ■ Benefits • • • • • • p High measuring accuracy Sturdy stainless steel housing For aggressive and non-aggressive media For measuring the pressure of liquids, gases and vapor Temperature-compensated measuring cell Compact design ■ Application The pressure transmitter of the Z series for gage pressure and absolute pressure (7MF1564-...) is used above all in the following industrial areas: • Chemical industry • Pharmaceutical industry • Food industry • Mechanical engineering • Shipbuilding • Water supply ■ Design The design of the pressure transmitter is dependent on the measuring range. Measuring range <1 bar (<14.5 psi) Main components: • Stainless steel housing with piezo-resistive silicon measuring cell (with stainless steel diaphragm, temperature-compensated) and electronics module • Process connection made of stainless steel in diverse designs (see Selection and Ordering data) • Electrical connection made using a plug to DIN 43650 with the cable inlet M16 x 1.5, ½-14 NPT or round plug connector M12. The pressure transmitters with a nominal range < 1 bar g (< 14.5 psi g) are optionally available with or without explosion protection. 2/6 U const. Siemens FI 01 · 2009 U I I0, UB SITRANS P pressure transmitters, Z series (7MF1564-...), functional diagram The mode of operation of the pressure transmitter is dependent on the measuring range. Measuring range <1 bar (<14.5 psi) The silicon measuring cell of the pressure transmitter has a piezo-resistive bridge to which the operating pressure is transmitted through silicone oil and a stainless steel diaphragm. The measuring cell output voltage is fed to an amplifier and converted into an output current 4 ... 20 mA. The output current is linearly proportional to the input pressure Measuring range ≥1 bar (≥14.5 psi) The thin-film measuring cell has a thin-film resistance bridge to which the operating pressure p is transmitted through a ceramic diaphragm. The voltage output from the measuring cell is converted by an amplifier into an output current 4 ... 20 mA or an output voltage of 0 ... 10 V DC. The output current and voltage are linearly proportional to the input pressure © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure Z series for gage and absolute pressure ■ Technical specifications Power supply UH SITRANS P pressure transmitters, Z series for gage pressure, absolute pressure and level Mode of operation Terminal voltage on pressure transmitter • For current output 10 ... 36 V DC 15 ... 36 V DC • Measuring range <1 bar (<14.5 psi) Piezo-resistive • For voltage output signal (only measuring range ≥ 1 bar (14.5 psi)) • Measuring range ≥1 bar (≥14.5 psi) Thin-film strain gage Certificate and approvals Gage and absolute pressure Classification according to pressure equipment directive (DRGL 97/23/EC) Input Measured variable Measured range • Pressure 2 For gases of fluid group 1 and liquids of fluid 1; complies with requirements of article 3, paragraph 3 (sound engineering practice) Explosion protection - Metric 0 ... 400 bar g (0 ... 5802 psi g) - US measuring range 0 ... 6000 psi g • Intrinsic safety "i" (only with current output) - Identification • Absolute pressure - Metric 0 ... 16 bar a (0 ... 232 psi a) - US measuring range 0 ... 300 psi a TÜV 02 ATEX 1953X Ex II 1/2G EEx ia IIC T4 • Intrinsic safety "T.I.I.S." (only with current output) applied Lloyds Register of Shipping Certificate No. 03/30003 Output Output signal Accuracy To EN 60770-1 Error in measurement (at 25 °C (77 °F), including conformity error, hysteresis and repeatability) 0.25% of full-scale value – typical Response time T99 < 0.1 s Long-term drift • Start of scale 0.25% of full scale value/year • Full-scale value 0.25% of full scale value/year ■ Dimensional drawings 132 (5.2) without Ex protection1) 5 (0.2) 20 (0.8) SW27 Influence of ambient temperature 0.25%/10 K (0.25%/10 K) of fullscale value Rated operating conditions Process temperature -30 ... +120 °C (-22 … +248 °F) Ambient temperature -25 ... +85 °C (-13 … +185 °F) Storage temperature -50 ... +100 °C (-58 … +212 °F) Degree of protection to EN 60529 IP65 Design ≈ 0.25 kg (≈ 0.55 lb) M16x1,5 or ½-14 NPT Pressure transmitter 7MF1564-... with process connection G½" male, dimensions in mm (inch) 122 (4.8) without Ex protection1) 16 131 (5.15) with Ex protection (0.63) 50 (1.97) • Full-scale value 1) Length on version for voltage output 0 ... 10 V: 106 (4.2) 2) Inner diameter 3 (0.12) Ø 27 (diam. 1.1) 0.25%/10 K (0.25%/10 K) of fullscale value G¼B2) • Start of scale Weight 141 (5.6) with Ex protection 50 (1.97) 0 ... 10 V DC Ø 27 (diam. 1.1) 4 ... 20 mA • Voltage output signal (only measuring range ≥ 1 bar (14.5 psi)) G½B2) • Current output signal Wetted parts materials SW27 • Measuring cell - Measuring range <1 bar (<14.5 psi) Stainless steel, 1.4571/316Ti - Measuring range ≥1 bar (≥14.5 psi) Al2O3 – 96% • Process connection Stainless steel, mat. No. 1.4571/316Ti • Gasket Viton Process connection See Selection and Ordering data 1) Length on version for voltage output 0 ... 10 V: 96 (3.8) 2) Inner diameter 3 (0.12) M16x1,5 or ½-14 NPT Pressure transmitter 7MF1564-... with process connection G¼" male, dimensions in mm (inch) Siemens FI 01 · 2009 2/7 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure ZLWKRXW([SURWHFWLRQ ZLWK([SURWHFWLRQ ZLWKRXW([SURWHFWLRQ ZLWK([SURWHFWLRQ /HQJWKRQYHUVLRQIRUYROWDJH RXWSXW9 6: 0[ RU 137 Pressure transmitter 7MF1564-... with process connection ½"-14 NPT male, dimensions in mm (inch) ZLWKRXW([SURWHFWLRQ ZLWK([SURWHFWLRQ 6: GLDP 137 GLDP 137 ZLWKRXW([SURWHFWLRQ ZLWK([SURWHFWLRQ /HQJWKRQYHUVLRQIRUYROWDJH RXWSXW9 0[ RU 137 /HQJWKRQYHUVLRQIRUYROWDJH RXWSXW9 Pressure transmitter 7MF1564-... with process connection 7/16-20 UNF male, dimensions in mm (inch) GLDP 137 6: 0[ RU 137 /HQJWKRQYHUVLRQIRUYROWDJH RXWSXW9 Pressure transmitter 7MF1564-... with process connection ¼"-18 NPT male, dimensions in mm (inch) 6: GLDP 0[ RU 137 Pressure transmitter 7MF1564-... with process connection ½"-14 NPT female, dimensions in mm (inch) ■ Schematics 124 (4.88) without Ex protection1) 133 (5.23) with Ex protection 28 (1.1) SW27 1) Length on version for voltage output 0 ... 10 V: 98 (3.9) Signal M16x1.5 or ½-14 NPT Signal 129 (5.2) without Ex protection1) 138 (5.6) with Ex protection 50 (1.97) Ø 27 (diam. 1.1) SW39 M16x1,5 or ½-14 NPT Pressure transmitter 7MF1564-... with process connection G1“ male, dimensions in mm (inch) Siemens FI 01 · 2009 RL UB 3+ 2- + U0 RL UB I0 Output current UB Power supply RL Load Connections: 1 (+UB) 2 (-UB) U0 Output voltage UB Power supply RL Load Connections: 1 (+UB) 2 (-UB) 3 (U0) SITRANS P pressure transmitters, Z series (7MF1564-...), connection diagram, with current output (top) and voltage output (bottom) 21 (0.8) 2/8 I0 2- 1+ Pressure transmitter 7MF1564-... with process connection ¼"-18 NPT female, dimensions in mm (inch) 1) Length on version for voltage output 0 ... 10 V: 103 (4.1) + 50 (1.97) ¼-18 NPT Ø27 (diam. 1.1) 1+ G1 2 81) Z series for gage and absolute pressure © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure Z series for gage and absolute pressure ■ Selection and Ordering data Order No. Measuring range perm. working pressure Min. Order code D) 7 MF 1 5 6 4 - 7 7 7 7 7 - 7 7 7 1 SITRANS P pressure transmitters for pressure, series Z for gage and absolute pressure 2 or 3-wire system, rising characteristic curve 777 Burst pressure 2 Max. For gage pressure with metal measuring cell 0 ... 100 mbar g 0 ... 160 mbar g 0 ... 250 mbar g 0 ... 400 mbar g 0 ... 600 mbar g (0 ... 1.45 psi g) (0 ... 2.32 psi g) (0 ... 3.63 psi g) (0 ... 5.80 psi g) (0 ... 8.70 psi g) -0,6 bar g -0,6 bar g -1 bar g -1 bar g -1 bar g (-8.7 psi g) (-8.7 psi g) (-14.5 psi g) (-14.5 psi g) (-14.5 psi g) 0,6 bar g 0,6 bar g 1 bar g 1 bar g 3 bar g (8.7 psi g) (8.7 psi g) (14.5 psi g) (14.5 psi g) (43.5 psi g) 1 bar g 1 bar g 1.7 bar g 1.7 bar g 5 bar g (14.5 psi g) (14.5 psi g) (25 psi g) (25 psi g) (72 psi g) } } } } } 3 AA 0 3 AB 0 3 AC 0 3 AD 0 3 AG 0 9 AC 0 Other version for measuring range < 1 bar (< 14.5 psi g), add Order code and plain text: measuring range: ... up to ... mbar g (psi g)1) H1Y with ceramic measuring cell 0 ... 1 bar g 0 ... 1.6 bar g 0 ... 2.5 bar g 0 ... 4 bar g 0 ... 6 bar g (0 ... 14.5 psi g) (0 ... 23.2 psi g) (0 ... 36.3 psi g) (0 ... 58.0 psi g) (0 ... 87.0 psi g) -0,4 bar g -0,4 bar g -0,8 bar g -0,8 bar g -1 bar g (-5.8 psi g) (-5.8 psi g) (-11.6 psi g) (-11.6 psi g) (-14.5 psi g) 2 bar g 3,2 bar g 5 bar g 8 bar g 12 bar g (30 psi g) (45 psi g) (72 psi g) (115 psi g) (175 psi g) 5 bar g 5 bar g 12 bar g 12 bar g 25 bar g (72 psi g) (72 psi g) (175 psi g) (175 psi g) (360 psi g) } } } } } 3 BA 3 BB 3 BD 3BE 3 BG 0 ... 10 bar g 0 ... 16 bar g 0 ... 25 bar g 0 ... 40 bar g 0 ... 60 bar g (0 ... 145 psi g) (0 ... 232 psi g) (0 ... 363 psi g) (0 ... 580 psi g) (0 ... 870 psi g) -1 bar g -1 bar g -1 bar g -1 bar g -1 bar g (-14.5 psi g) (-14.5 psi g) (-14.5 psi g) (-14.5 psi g) (-14.5 psi g) 20 bar g 32 bar g 50 bar g 80 bar g 120 bar g (290 psi g) (460 psi g) (725 psi g) (1150 psi g) (1750 psi g) 50 bar g 50 bar g 120 bar g 120 bar g 250 bar g (725 psi g) (725 psi g) (1750 psi g) (1750 psi g) (3600 psi g) } } } } } 3 CA 3 CB 3 CD 3CE 3 CG 0 ... 100 bar g 0 ... 160 bar g 0 ... 250 bar g 0 ... 400 bar g (0 ... 1450 psi g) (0 ... 2320 psi g) (0 ... 3626 psi g) (0 ... 5802 psi g) -1 bar g -1 bar g -1 bar g -1 bar g (-14.5 psi g) (-14.5 psi g) (-14.5 psi g) (-14.5 psi g) 200 bar g 320 bar g 500 bar g 600 bar g (2900 psi g) (4640 psi g) (7250 psi g) (8700 psi g) 450 bar g 450 bar g 650 bar g 650 bar g (6525 psi g) (6525 psi g) (9425 psi g) (9425 psi g) } } } } 3 DA 3 DB 3 DD 3DE Other version for measuring range ≥ 1 bar g (≥ 14.5 psi g), add Order code and plain text: measuring range: ... up to... bar (psi g)1) 9 AA H1Y For absolute pressure 0 ... 600 mbar a 0 ... 1 bar a 0 ... 1.6 bar a 0 ... 2.5 bar a (0 ... 8.7 psi a) (0 ... 14.5 psi a) (0 ... 23.2 psi a) (0 ... 36.3 psi a) 0 bar a 0 bar a 0 bar a 0 bar a (0 psi a) (0 psi a) (0 psi a) (0 psi a) 3 bar a 2 bar a 3,2 bar a 5 bar a (43.5 psi a) (30 psi a) (45 psi a) (72 psi a) 5 bar a 5 bar a 5 bar a 12 bar a (72 psi a) (72 psi a) (72 psi a) (175 psi a) } } } } J) J) J) J) 5 AG 0 5 BA 5 BB 5 BD 0 ... 4 bar a 0 ... 6 bar a 0 ... 10 bar a 0 ... 16 bar a (0 ... 58.0 psi a) (0 ... 87.0 psi a) (0 ... 145 psi) (0 ... 232 psi) 0 bar a 0 bar a 0 bar a 0 bar a (0 psi a) (0 psi a) (0 psi a) (0 psi a) 8 bar a 12 bar a 20 bar a 32 bar a (115 psi a) (175 psi a) (290 psi a) (460 psi a) 12 bar a 25 bar a 50 bar a 50 bar a (175 psi a) (360 psi a) (725 psi a) (725 psi a) } } } } J) J) J) J) 5BE 5 BG 5 CA 5 CB J) 9 AB 0 Other version for measuring range < 1 bar (< 14.5 psi a), add Order code and plain text: measuring range: ... up to ... mbar a (psi a) } Available ex stock 1) H1Y D) Subject to export regulations AL: N, ECCN: EAR99H. J) Subject to export regulations AL: 9I999, ECCN: EAR99. The transmitters can also be ordered with special measuring ranges, e.g. the transmitter with the 1 bar measuring cell (14.5 psi measuring cell): -0.2 ... +0.8 bar g (-2.9 ... +11.6 psi g) or -0.4 ... +0.6 bar g (-5.8 ... +8.7 psi g) or ..., however start-of-scale value not under -0.4 bar g (-5.8 psi g), also see column "min. perm. operating pressure" Please note: • It is not possible to have a smaller span than the smallest span of the device of the entire device range. • The value must not fall below the minimum permissible operating pressure of the special measuring range of the selected measuring cell. • The required span of the device must lie between the smallest and the largest possible span of the entire device range. Siemens FI 01 · 2009 2/9 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure Z series for gage and absolute pressure ■ Selection and Ordering data Order No. SITRANS P pressure transmitters for pressure, series Z for pressure and absolute pressure 2 or 3-wire system, rising characteristic curve Measuring range 2 Perm. working pressure min. Order code D) 7 MF 1 5 6 4 - 7 7 7 7 7 - 7 7 7 1 777 Burst pressure max. Measuring ranges for gage pressure (only for US market) (0 ... 10 psi g) (0 ... 15 psi g) (3 ... 15 psi g) (0 ... 20 psi g) (0 ... 30 psi g) (-3 psi g) (-6 psi g) (-6 psi g) (-6 psi g) (-6 psi g) (20 psi g) (30 psi g) (30 psi g) (40 psi g) (60 psi g) (60 psi g) (72 psi g) (72 psi g) (72 psi g) (72 psi g) 4 BA 4 BB 4 BC 4 BD 4BE (0 ... 60 psi g) (0 ... 100 psi g) (0 ... 150 psi g) (0 ... 200 psi g) (0 ... 300 psi g) (-11.5 psi g) (-14.5 psi g) (-14.5 psi g) (-14.5 psi g) (-14.5 psi g) (120 psi g) (200 psi g) (300 psi g) (400 psi g) (600 psi g) (175 psi g) (360 psi g) (725 psi g) (725 psi g) (1750 psi g) 4BF 4 BG 4 CA 4 CB 4 CD (0 ... 500 psi g) (0 ... 750 psi g) (0 ... 1000 psi g) (0 ... 1500 psi g) (0 ... 2000 psi g) (-14.5 psi g) (-14.5 psi g) (-14.5 psi g) (-14.5 psi g) (-14.5 psi g) (1000 psi g) (1500 psi g) (2000 psi g) (3000 psi g) (4000 psi g) (1750 psi g) (3600 psi g) (3600 psi g) (6525 psi g) (6525 psi g) 4CE 4CF 4 CG 4 DA 4 DB (0 ... 3000 psi g) (0 ... 5000 psi g) (0 ... 6000 psi g) (-14.5 psi g) (-14.5 psi g) (-14.5 psi g) (6000 psi g) (8700 psi g) (8700 psi g) (9425 psi g) (9425 psi g) (9425 psi g) 4 DD 4DE 4DF 9 BA Other version, add Order code and plain text: Measuring range: ... up to ... psi g H1Y Measuring ranges for absolute pressure (only for US market) (0 ... 10 psi a) (0 ... 15 psi a) (0 ... 20 psi a) (0 ... 30 psi a) (0 ... 60 psi a) (0 psi a) (0 psi a) (0 psi a) (0 psi a) (0 psi a) (20 psi a) (30 psi a) (40 psi a) (60 psi a) (120 psi a) (60 psi a) (72 psi a) (72 psi a) (72 psi a) (175 psi a) J) J) J) J) J) 6 AG 6 BA 6 BB 6 BD 6BE (0 ... 100 psi a) (0 ... 150 psi a) (0 ... 200 psi a) (0 ... 300 psi a) (0 psi a) (0 psi a) (0 psi a) (0 psi a) (200 psi a) (300 psi a) (400 psi a) (600 psi a) (360 psi a) (725 psi a) (725 psi a) (1725 psi a) J) J) J) J) 6 BG 6 CA 6 CB 6 CC J) 9 BB Other version, add Order code and plain text: Measuring range: ... up to ... psi a H1Y Output signal 4 ... 20 mA;C 2-wire system; power supply 10 ... 36 V DC 0 ... 10 V; 3-wire system; power supply 15 ... 36 V DC } 0 10 } 0 1 Explosion protection Without With explosion protection Ex II 1/2 G EEx ia IIC T4 (only for version 4 ... 20 mA; 2-wire system; power supply 10 ... 30 V DC) With explosion protection "Intrinsic safety T.I.I.S." (available soon) 2 Electrical connection Plug to DIN 43650, Form A, cable inlet M16 x 1.5 Round connector M12, IP67 Plug to DIN 43650, cable inlet ½-14 NPT Plug to DIN 43650, cable inlet Pg11 Cable gland Pg11 with 2 m PE cable, IP68 Special version (specify Order code and plain text) } Available ex stock 2/10 D) Subject to export regulations AL: N, ECCN: EAR99H. J) Subject to export regulations AL: 9I999, ECCN: EAR99. Siemens FI 01 · 2009 } 1 2 3 4 6 9 N1Y © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure Z series for gage and absolute pressure ■ Selection and Ordering data Order No. SITRANS P pressure transmitters for pressure, series Z for pressure and absolute pressure 2 or 3-wire system, rising characteristic curve Order code D) 7 MF 1 5 6 4 - 7 7 7 7 7 - 7 7 7 1 777 Process connection G½" male to EN 837-1 (½" BSP male) (standard for metric pressure ranges mbar, bar) G½" male thread and G1/8" female thread G¼“ male to EN837-1 (¼“ BSP male) 7/16"-20 UNF male ¼"-18 NPT male (standard for pressure ranges psi) } 2 A B C D E F G H K M ¼"-18 NPT female ½"-14 NPT male ½"-14 NPT female RC ½" male to JIS B 7505 G1" male (only for measuring ranges ≥ 1 bar g (14.5 psi g)) and max. permissible working pressure 100 bar g (1450 psi g) Special version (specify Order code and plain text) Z P1Y Sealing material between sensor and housing Viton (standard) Neoprene Perbunan Special version (specify Order code and plain text) } A B C Z Quality inspection certificate (Factory calibration) to IEC 60770-2, add "-Z" to Order No. and Order code. C11 Oxygen version, oil and grease-free cleaning (only if the sealing material between sensor and housing is Viton and only for measuring ranges ≥ 1 bar g (≥ 14.5 psi g) and ≥ 1 bar a (≥ 14.5 psi a) E10 Order No. Accessories Quality inspection certificate (Factory calibration) to IEC 60770-2 supplied later, specify factory no. of transmitter. } Available ex stock Q1Y Order code / Order No. Further designs D) 7MF1564-8CC11 D) Subject to export regulations AL: N, ECCN: EAR99H. Siemens FI 01 · 2009 2/11 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure SITRANS P250 for differential pressure ■ Overview Mode of operation p1 p2 U const. 2 U I I0, UB SITRANS P250 pressure transmitter, function diagram The piezo-resistive ceramic measuring cell (membrane) has a Wheatstone bridge circuit, on which the operating pressure P1 and P2 of the media acts at both ends. The voltage output from the measuring cell is converted by an amplifier into an output current of 4 to 20 mA or an output voltage of 0 to 5 or 10 V DC. SITRANS P250 transmitter for differential pressure The SITRANS P250 transmitter measures the differential pressure of liquids and gases. ■ Benefits ■ Technische Daten SITRANS P250 differential pressure transmitter • • • • High measuring accuracy Sturdy stainless steel enclosure For aggressive and non-aggressive media For the measurement of the differential pressure of liquids and gases • Temperature-compensated measuring cell • Compact design ■ Application The SITRANS P250 transmitter for differential pressure is primarily used in the following industries: • Chemical industry • Pharmaceutical industry • Food industry • Mechanical engineering • Shipbuilding • Water supply ■ Design Application Differential pressure transmitter Liquids and neutral gases Mode of operation Measuring principle Piezo-resistive measuring cell (ceramic diaphragm) Input Measured variable Differential pressure Measuring range 0 ... 0.1 to 0 ... 25 bar (0 ... 1.45 to 0 ... 363 psi) Operating pressure ≤ 25 bar (363 psi) at a differential pressure range < 6 bar (87 psi) ≤ 50 bar (725 psi) at a differential pressure range > 10 bar (145 psi) Burst pressure 1.5 x operating pressure Output Output signal • Current output signal 4 ... 20 mA • Voltage output signal 0 ... 5 V and 0 ... 10 V DC Load Main components: • Stainless steel enclosure with piezo-resistive ceramic measuring cell and (temperature-compensated) electronics module. • Process connection made of stainless steel in diverse designs (see Selection and ordering data) • Electrical connection through connectors acc. to EN 175301803-A and round connectors M12, as well as with permanently fixed cable ■ Function The pressure transmitter measures the differential pressure of liquids and gases. 2/12 The output current and voltage are linearly proportional to the input pressure. Siemens FI 01 · 2009 3-wire > 10 kΩ 2-wire ≤ (UH - 11 V) / 0.02 A Measuring accuracy Dynamic behavior (at 25°C (77°F), including conformity error, hysteresis and repeatability) ≤ 1 % of typical full-scale value, see "Measuring range" table Long-term drift acc. to IEC 60770 ≤ 0.5 % of full-scale value/year Influence of ambient temperature • Start of scale ≤ 0.6 %/10 K of full-scale value (≤ 1.2 %/10 K for measuring cell 0 ... 0.1 bar (1.45 psi)) • Full-scale value ≤ 0.22 %/10 K of full-scale value (≤ 0.37 %/10 K for measuring cell 0 ... 0.1 bar (1.45 psi)) Dynamic behavior Suitable for static and dynamic measurements Response time T99 < 5 ms Load variation < 50 Hz © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure SITRANS P250 for differential pressure Measuring range Conditions of use Ambient conditions • Temperature of medium -15 ... +85 °C (5 ... 185 °F) Max. per- Burst missible pressure operating pressure (on either side) Max. per- Accuracy missible operating pressure (on one side) • Ambient temperature -15 ... +85 °C (5 ... 185 °F) • Storage temperature -40 ... +85 °C (-40 ... +185 °F) [bar] [psi] Degree of protection acc. to EN 60529 IP65 0 ... 0.1 0 ... 1.45 25 bar (363 psi) 37,5 bar (544 psi) 0.6 bar (8.7 psi) ≤ 1,0 % Mounting position Any 0 ... 0.2 0 ... 2.9 Mounting bracket, included in delivery 25 bar (363 psi) 37,5 bar (544 psi) 0.6 bar (8.7 psi) ≤ 1,0 % Mounting 0 ... 0.25 0 ... 3.63 25 bar (363 psi) 37,5 bar (544 psi) 0.6 bar (8.7 psi) ≤ 0,5 % Weight Approx. 430 g (approx. 0.95 lb) 0 ... 0.3 0 ... 4.35 25 bar (363 psi) 37,5 bar (544 psi) 0.6 bar (8.7 psi) ≤ 0,5 % Enclosure material Stainless steel 1.4305/AISI 303 0 ... 0.4 0 ... 5.8 Electrical connection • Plug EN 175301-803-A • Circular plug EN 60130-9 • Cable 1.5 m 25 bar (363 psi) 37,5 bar (544 psi) 1.2 bar (17.4 psi) ≤ 0,8 % 0 ... 0.5 0 ... 7.25 25 bar (363 psi) 37,5 bar (544 psi) 1.2 bar (17.4 psi) ≤ 0,5 % 0 ... 0.6 0 ... 8.7 25 bar (363 psi) 37,5 bar (544 psi) 1.2 bar (17.4 psi) ≤ 0,5 % Design Process connection • Hose sleeve Ø 4 mm/6 mm • Pipe union Ø 6 mm/8 mm • Male thread 7/16-20 UNF, G1/8 • Female thread 1/8-27 NPT • (Standard), G1/8 0 ... 1.0 0 ... 14.5 25 bar (363 psi) 37,5 bar (544 psi) 2 bar (29 psi) ≤ 0,5 % 0 ... 1.6 0 ... 23.2 25 bar (363 psi) 37,5 bar (544 psi) 3.2 bar (46.4 psi) ≤ 0,5 % Wetted parts materials Stainless steel 1.4305/AISI 303, CuZn nickel-plated 0 ... 2.5 0 ... 36.3 25 bar (363 psi) 37,5 bar (544 psi) 5 bar (72.5 psi) ≤ 0,5 % • Process connection Approx. 430 g (approx. 0.95 lb) 0 ... 4 0 ... 58 • Diaphragm Ceramic Al2O3 (96 %) 25 bar (363 psi) 37,5 bar (544 psi) 8 bar (116 psi) ≤ 0,5 % • Sealing material FPM (standard), EPDM, NBR, MVQ, CR 0 ... 6 0 ... 87 25 bar (363 psi) 37,5 bar (544 psi) 12 bar (174 psi) ≤ 0,5 % 0 ... 10 0 ... 145 50 bar (725 psi) 75 bar 20 bar (1088 psi) (290 psi) ≤ 0,5 % 0 ... 16 0 ... 232 50 bar (725 psi) 75 bar 32 bar (1088 psi) (464 psi) ≤ 0,5 % 0 ... 25 0 ... 363 50 bar (725 psi) 75 bar 50 bar (1088 psi) (725 psi) ≤ 0,5 % Power supply UH Terminal voltage on pressure transmitter • 2-wire, 4 ... 20 mA 11 ... 33 V DC • 3-wire, 0 ... 5 V DC 11 ... 33 V DC/ 24 V AC ±15 % • 3-wire, 0 ... 10 V DC 18 ... 33 V DC/ 24 V AC ±15 % ■ Schematics Current consumption at nominal pressure • 2-wire < 20 mA • 3-wire < 5 mA Protection against polarity reversal Protected against short-circuit and polarity reversal. Each connection against the other with max. supply voltage. 1+ 1 2 IO Connection: 1 (+), 2 (-) + 2- UB RL IO Output current RL Load UB Power supply Connection with current output 4 ... 20 mA and plug to EN 175301-803-A Certificates and approvals Approval CE conformity 1+ 3 IO 2 1 Connection: 1 (+), 3 (-) + UB RL 3- IO Output current RL Load UB Power supply Connection with current output 4 ... 20 mA and round connector 1+ 2- IO Connection: 1 (+, brown), 2 (-, green) + RL UB IO Output current UB Power supply RL Load Connection with current output 4 ... 20 mA and permanently fixed cable Siemens FI 01 · 2009 2/13 2 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure SITRANS P250 for differential pressure 1+ 1 3 2 2+ U + UB RL O 3- 2 Round connector EN 60130-9 Connection: 1 (+UB), 2 (-), 3 (+U0) UO Output voltage RL Load UB Power supply 2 + UB RL 2 1 Connection: 1 (+UB, brown), 2 (+U0, green), 3 (-, white) UO Output voltage UB Power supply RL Load Connection with voltage output 0 ... 5 V DC (0 ... 10 V DC) and round connector 1+ UO 3+ + UB RL 2- Connection: 1 (+UB), 2 (-), 3 (+U0) Uo Output voltage UB Power supply RL Load (mounted) 3 UO 3 ~108(4.3) 1 ~158 (6.2) Connection with voltage output 0 ... 5 V DC (0 ... 10 V DC) and plug to EN 175301-803-A SITRANS P250 differential pressure transmitter with round connector to EN 60130-9, dimensions in mm (inch) Connection with voltage output 0 ... 5 V DC (0 ... 10 V DC) and permanently fixed cable Cable ■ Dimensional drawings (mounted) 102 (4.02) ~ 136 (5.4) Stainless P1 M4 44 (1.7) 5 (0.2) 15 ± 0,5 21 ± 0,8 P2 20 (0.79) X SITRANS P250 differential pressure transmitter with socket outlet to EN 175301-803-A, dimensions in mm (inch) 2/14 Siemens FI 01 · 2009 ~138 (5.4) ~95 (3.7) Ø 25 (0.98) Socket outlet EN 175301-803-A SITRANS P250 differential pressure transmitter with cable, dimensions in mm (inch) © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure SITRANS P250 for differential pressure Process connections Ø Width across flats [mm] [inch] Pipe union with screw-in nipple for outer pipe (stainless steel 1.4305/AISI 303) a X [mm] [inch] [mm] [inch] 6 a = 10 b = 12 24 65 8 a = 12 b = 14 26 67 Female thread G1/8 (stainless steel 1.4305/AISI 303) - a = 14 12 53 Pipe union with screw-in nipple for outer pipe (CuZn nickel-plated) 6 a = 10 b = 12 24 65 8 a = 12 b = 14 25 66 Hose connection for hose (CuZn nickel-plated, stainless steel 1.4571/AISI 316TI) 4 a = 10 20 61 6 a = 10 25 66 Male thread G1/8 (CuZn nickel-plated) - a = 10 b = 12 20 61 Male thread G1/8 7/16-20 UNF (CuZn nickel-plated) - a = 14 18 59 1/8-27 NPT L L 2 b 1/8-27 NPT L G1/8 a 1/8-27 NPT L b a 1/8-27 NPT L a 1/8-27 NPT L b L 1/8-27 NPT 7/16-20 UNF a a Siemens FI 01 · 2009 2/15 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure SITRANS P250 for differential pressure ■ Selection and ordering data Order No. Order code 7 M F 1 6 4 1 - 7777 0 - 777 0 777 SITRANS P 250 pressure transmitter for differential pressure Accuracy ≤ 1 %, wetted parts ceramic/stainless steel 1.4301, scope of delivery: transmitter, mounting bracket and instruction manual, without explosion protection 2 Measuring range 0 ... 0.1 bar 0 ... 0.2 bar 0 ... 0.25 bar 0 ... 0.3 bar 0 ... 0.4 bar 0 ... 0.5 bar 0 ... 0.6 bar 0 ... 1.0 bar 0 ... 1.6 bar 0 ... 2.5 bar 0 ... 4.0 bar 0 ... 6.0 bar 0 ... 10.0 bar 0 ... 16.0 bar 0 ... 25.0 bar (0 ... 1.45 psi) (0 ... 2.90 psi) (0 ... 3.63 psi) (0 ... 5.35 ps) (0 ... 5.80 psi) (0 ... 7.25 psi) (0 ... 8.70 psi) (0 ... 14.5 psi) (0 ... 23.2 psi) (0 ... 36.3 psi) (0 ... 58.0psi) (0 ... 87.0 psi) (0 ... 145 psi) (0 ... 232 psi) (0 ... 363 psi) } } } } } } } } } } } } } } } 3 AA 3 AC 3 AD 3AE 3AF 3 AG 3 AH 3 BA 3 BB 3 BD 3BE 3 BG 3 CA 3 CB 3 CD Output signal } 4 ... 20 mA 0 ... 5 V DC 0 ... 10 V DC Electrical connection • Plug acc. to EN 175 301-803-A (suitable coupling included in scope of delivery) • Round connector acc. to EN 60139-9 • Cable 1.5 m with cable gland Process connection • Without connections, female thread 1/8-27 NPT • Hose connection - CuZn nickel-plated, for hose ∅ 4 mm - CuZn nickel-plated, for hose ∅ 6 mm - PVDF, for hose ∅ 6 mm • Pipe union - CuZn nickel-plated, for pipe ∅ 6 mm - Stainless steel 1.4304, for pipe ∅ 6 mm - CuZn nickel-plated, for pipe ∅ 8 mm - Stainless steel 1.4304, for pipe ∅ 8 mm • Male thread, 7/16-20 UNF (CuZn nickel-plated) • Adapter - Inner, G1/8 (stainless steel), for pipe ∅ 6 mm - Outer, with union nut, for pipe ∅ 6 mm sealing material • Fluoro rubber (Viton/FPM) • Ethylene propylene diene monomer rubber (EPDM) • Nitrile butadiene rubber (NBR) • Silicone rubber (MVQ) • Neoprene (CR) Weitere Ausführungen 0 1 2 } 1 2 3 } A B C D E F G H L M N } A B C D E Kurzangabe Please add "-Z" to Order No. and specify Order code(s). Quality inspection certificate (Factory calibration) to IEC 60770-2 supplied } Available ex stock 2/16 Siemens FI 01 · 2009 C11 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure ZD series for gage and absolute pressure ■ Overview At the rear of the housing is the electrical connection for the voltage supply using a current loop 4 ... 20 mA. The connection is made with a plug connector. At the front of the housing is the 5-digit display behind a glass cover. Underneath the display are the 3 keys for parameterizing the pressure transmitter. Above the display are a green and a red LED for indicating the operating status. The ZD pressure transmitter is available in two versions (see "Dimension drawing"): In the radial version (type A) the display is fitted in parallel with the process connection. The display can be rotated by up to ±120° relative to the process connection. In the axial version (type B) the display is at right angles to the process connection. The display can be rotated by 360° relative to the process connection. ■ Function Green LED U ref Red LED LCD 600.00 P SITRANS P pressure transmitters, ZD series, are for measuring the gage pressure, absolute pressure and level of liquids and gases. ■ Benefits • • • • • • • Robust stainless steel housing with 2 connection versions Integrated display with status messages Thin-film measuring cell with ceramic diaphragm 2-wire system, 4 ... 20 mA Parameterizable using keys underneath the housing cover Range adjustment 1:5 (max. 1:10) Measuring accuracy < 0.25% (typical) ■ Application The ZD is a configurable pressure transmitter for measuring the gage and absolute pressure of gases, liquids and vapor. It is equipped with a display for indicating the pressure value at the point of installation. SITRANS P pressure transmitters, ZD series, are used in the following industrial areas for example: • Chemical industry • Mechanical engineering • Food industry • Pharmaceutical industry • Shipbuilding • Water supply ■ Design The pressure transmitter is comprised of a thin-film measuring cell with a ceramic diaphragm, an electronics board and a digital indicator. All parts are accommodated in a stainless steel field housing (∅ 80 mm) with a glass cover and stainless steel process connection. A/D 3 keys EEP RO M They are used to indicate and monitor the pressure measured at the point of installation. ZD pressure transmitters are available in an axial and a radial version. UK D/A 3 keys A/D D/A EEPROM EMC IA Uref LCD Green LED Red LED P UH µC mbar µC UA EMC U I + 4 ... 20 mA UH, IA - Configuring of parameters Analog-to-digital converter Digital-to-analog converter Memory for all parameters Output stage with protective components Output current Reference voltage Display of measured values with dimensions Display of normal mode Display of error messages or limit violation Ceramic measuring cell Power supply Microcontroller for computing functions and monitoring SITRANS P pressure transmitters, ZD series, mode of operation Mode of operation The ZD pressure transmitter has a thin-film strain gage which is mounted on a ceramic diaphragm. The measuring cell is temperature-compensated. Functions The ZD pressure transmitter has a 5-digit display behind a glass cover. The following data are shown on the display: • Measured pressure • Technical pressure dimension (default setting: bar) • Limit violation in upward or downward direction, indicated by LED and arrow symbols in the display The pressure transmitter is set using the 3 input keys behind the glass cover underneath the display. The key "M" is used to select the operating mode. Following modes of operation are available: • Measured value • Password • Dimension • Start and end of scale • Upper and lower limit value • Zero adjustment Siemens FI 01 · 2009 2/17 2 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure ZD series for gage and absolute pressure 2 • Upper and lower current saturation limit • Electrical damping Rated conditions The other two keys are used to set the values in the individual operating modes. • Ambient temperature -25 ... +85 °C (-13 ... +185 °F) • Storage temperature -40 ... +85 °C (-40 ... +185 °F) Two LED indicators are fitted above the display to monitor the set range and the status. Medium conditions The green LED signals that the measured pressure lies within the set limits. The red LED lights up when the measured pressure lies outside the set limits and when there is an error. Ambient conditions • Process temperature -30 ... +100 °C (-22 ... +212 °F) Degree of protection IP65 to EN 60529 Electromagnetic compatibility • Emitted interference and interference immunity ■ Technical specifications To EN 61326/A1 appendix A (1998) SITRANS P pressure transmitters, ZD series Displays and controls Mode of operation Display LCD, max. 5 digits, digit height 9 mm Decimal point Freely parameterizable Limit values Freely parameterizable Limit violation display Red LED and message on LCD (↑ symbol /↓ symbol in case of limit violation in upward / downward direction) Parameterization With 3 keys Units mA or % or physical variable (default setting: bar) Other dimensions: mbar, kPa, MPa, mmH20, mH20, psi, inH20, mmHg, kg/cm², torr, atm Between 0.1 and 100 s (increment: 0.1 s) freely parameterizable Measuring principle Thin-film strain gage Input Measured variable Gage and absolute pressure Measured range Resolution 0 ... 2 bar (0 ... 29 psi) 0.6 mbar (0.008 psi) 0 ... 10 bar (0 ... 145 psi) 3 mbar (0.044 psi) 0 ... 50 bar (0 ... 725 psi) 15 mbar (0.218 psi) 0 ... 200 bar (0 ... 2900 psi) 60 mbar (0.9 psi) 0 ... 400 bar (0 ... 5800 psi) 120 mbar (1.8 psi) Measured range Overload limit 0 ... 2 bar (0 ... 29 psi) 5 bar (72.5 psi) 0 ... 10 bar (0 ... 145 psi) 25 bar (363 psi) 0 ... 50 bar (0 ... 725 psi) 120 bar (1740 psi) 0 ... 200 bar (0 ... 2900 psi) 500 bar (7250 psi) Weight ≈0.6 kg (≈1.32 lb) 0 ... 400 bar (0 ... 5800 psi) 600 bar (8700 psi) Electrical connection Range adjustment (turndown) 5:1 Using 2-pole plug connector with M16x1.5-Cable inlet to EN 175301-803A, plastic Process connection • Male thread G½B and female thread G1/8B • G½B to EN 837-1 • Female thread: ½-14 NPT Output Damping Design Output signal 4 ... 20 mA Lower current limit min. 3.6 mA Upper current limit max. 23 mA Output protected against Reversed polarity, overvoltage and short-circuiting Max. load R B = (UH - 12 V) / 0.023 A Voltage measurement Linear rising Measuring accuracy To EN 60770-1 Error in measurement (including non-linearity, hysteresis and repeatability, at 25 °C (77 °F)) < 0.25% of full-scale value (typical), max. 0.5% • Field housing Ø 80 mm (3.15 inch), stainless steel mat. No. 1.4016 Adjustment time < 100 ms • Cover Stainless steel, mat. No. 1.4016 with glass Long-term drift 0.25% of full scale value/year Influence of ambient temperature < ±0.25%/10 K (< ±0.25%/10 K) of full-scale value Vibration influence Power supply effect 0.05%/g to 500 Hz in all directions (to IEC 68-2-64) Version of housing/process connec- • Radial (type A), can be swiveled tion by max. ±120° (α) • Axial (type B), can be swiveled by max. ±360° Material Non-wetted parts materials Wetted parts materials • Measuring cell Al2O3 • Gasket Viton • Process connection Stainless steel, mat. No. 1.4571/316Ti < ±0.01%/V of full-scale value Power supply Terminal voltage on pressure transmitter (UH) 12 ... 30 V DC Certificate and approvals Classification according to pressure equipment directive 97/23/EC 2/18 Siemens FI 01 · 2009 For gases of fluid group 1 and liquids of fluid 1; complies with requirements of article 3, paragraph 3 (sound engineering practice) © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure ZD series for gage and absolute pressure ■ Dimensional drawings Ø 82 (3.23) Ø 82 (3.23) M16x1,5 or ½-NPT M16x1,5 or ½-NPT SW 27 a G½B EN 837-1 ½-14 NPT G½B Type A 152 (5.98) Ø 82 (3.23) s M 2 48,5 (1.91) 48,5 (1.91) 45 (1.77) 45 (1.77) G1/8B Type B SITRANS P pressure transmitters, ZD series, dimensional drawing, dimensions in mm (inch) ■ Schematics 1 (+) 1 I0 2 (-) 2 UB RL I0 + RL UB Power supply Load Output current SITRANS P pressure transmitters, ZD series, connection diagram Siemens FI 01 · 2009 2/19 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure ZD series for gage and absolute pressure 2 Selection and Ordering data Order No. Ord. Code Selection and Ordering data SITRANS P pressure transmitters, ZD series for gage and absolute pressure 7M F 1 5 8 0 - Further designs Conformity error 0.25%, range adjustment 1 : 5 (max. 1 : 10), housing and process connection made of stainless steel, membrane made of ceramic, 2-wire system, output 4 ... 20 mA 7777 0 Input variable Gage pressure } 1 Absolute pressure } 2 777 F) Measured range 0 ... 2 bar (0 ... 29 psi) Span 0 ... 0.4 / 2 bar (0 ... 5.8 / 29 psi) 0 ... 10 bar (0 ... 145 psi) } D 0 ... 2 / 10 bar (0 ... 5.8 / 145 psi) } E 0 ... 50 bar (0 ... 725 psi) 0 ... 10 / 50 bar (0 ... 145 / 725 psi) } F 0 ... 200 bar (0 ... 2900 psi) 0 ... 40 / 200 bar (0 ... 580 / 2900 psi) } G 0 ... 400 bar (0 ... 5800 psi) 0 ... 80 / 400 bar } (0 ... 1160 / 5800 psi) H Design Process connection vertically downwards, thread in connector M16x1.5 Process connection horizontally to rear, thread in connector M16x1.5 Process connection vertically downwards, thread in connector ½"-14 NPT Process connection horizontally to rear, thread in connector ½"-14 NPT 2/20 Siemens FI 01 · 2009 Please add "Z" to Order No. and specify Order code(s) and plain text. Quality inspection certificate (Factory calibration) to IEC 60770-2 supplied C1 1 Factory certificate to EN 10204-2.2 supplied C1 4 Oxygen application, oil and grease-free cleaned (only in conjunction with the sealing material Viton between sensor and enclosure and only in conjunction with measuring ranges >= 1 bar g and 1 bar abs) E1 0 Sealing material FEP between sensor and housing, instead of Viton max. operating pressure 15 bar (218 psi), max. measuring temperature -10 ... +50 °C E2 0 Additional data Please add "Z" to Order No. and specify Order code(s) and plain text. Z Other version (on request) add Order Code and plain text: Process connection: ............ Process connection G½B male thread and G1/8B female thread G½B to EN 837-1 Female thread ½-14 NPT G 1“ male thread Order Code } F) F) F) } J1Y A B C M Y0 1 TAG number made of stainless steel Y1 5 Accessories Order No. Quality inspection certificate (Factory calibration) to IEC 60770-2 supplied later, specify factory of transmitter. 7MF1564-8CC11 } Available ex stock 1 2 } Measuring range to be set, specify in plain text: Y01: ... up to ... mbar, bar, kPa, MPa, psi 3 4 F) Subject to export regulations AL: 9I999, ECCN: N. © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for food, pharmaceuticals and biotechnology SITRANS P Compact for gage and absolute pressure ■ Overview ■ Application The SITRANS P Compact pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials guarantees compliance with hygiene regulations. The SITRANS P Compact pressure transmitter is available in many versions. Exact adaptation of the pressure transmitter to conditions at the place of use is thus possible ■ Design The electronics is potted to protect it against moisture, corrosive atmospheres and vibration. Notes on operating the pressure transmitter Compensation of internal atmospheric pressure The SITRANS P Compact pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials guarantees compliance with hygiene regulations. Compensation of the internal atmospheric pressure of the SITRANS P Compact pressure transmitters is performed as follows: • in the plug versions by means of the screwed gland (IP65) • in the field housings by means of an integral sintered filter (IP65) or a vented cable (IP67) • in versions with cable outlet by means of a vented cable (IP67) In the absolute pressure range there is no need for compensation with respect to atmospheric pressure. Particular value has been placed on a high surface quality. It is therefore possible, for example, to guarantee roughness values down to Ra = 0.4 μm (1.57 ⋅ 10-5 inch) in the wetted area (welded seam area Ra < 0.8 μm (3.15 ⋅ 10-5 inch)). The system can be electropolished in addition. Note: These degrees of protection are only achieved under the following conditions: • if the pressure transmitter is installed correctly • if the screwed glands are securely tightened • if the cable diameters agree with the nominal diameters of the gaskets in the housing A further important feature is the hygiene-based design of the process connection by means of various aseptic connections. Note: The integral EMC measures are only effective if the earth connection is made correctly. The completely welded stainless steel housing can be designed up to degree of protection IP67. CE marking Using appropriate thermal decouplers, the SITRANS P Compact pressure transmitter can be used for process temperatures up to 200 °C (392 °F). ■ Benefits • Measuring ranges from 0 to 160 mbar (0 to 2.32 psi) to 0 to 40 bar (0 to 580 psi) • Linearity error including hysteresis < +0.2% of full-scale value • Piezo-resistive measurement system, vacuum-proof and overload-proof • Hygiene-based design according to EHEDG, FDA and GMP recommendations • Material and surface quality according to hygiene requirements • Wetted parts made of stainless steel; completely welded • Signal output 4 to 20 mA (0 to 20 mA as option) • Stainless steel housing with degree of protection IP65 (IP67 as option) • Process temperature up to 200 °C (392 °F) • Explosion protection II 2G EEx [ib] IIC T6 to ATEX • Easy and safe to clean The CE marking of the pressure transmitter certifies compliance with the guidelines of the European Council (9/336/EC), the EMC law (13.11.1992), as well as the applicable generic standards. Interference-free operation in systems and plants is achieved only if the specifications for shielding, earthing, cable routing and electrical isolation are observed during installation and assembly. Hazardous areas Note: Electrical equipment in hazardous areas must only be installed and operated by trained personnel. Modifications to units and connections result in cancellation of the explosion protection and guarantee. With intrinsically-safe circuits, make sure that equipotential bonding exists throughout the complete cabling inside and outside of the hazardous area. The limits specified in the ATEX approval must be observed. Siemens FI 01 · 2009 2/21 2 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for food, pharmaceuticals and biotechnology SITRANS P Compact for gage and absolute pressure ■ Function 2 Rated conditions The process pressure acts on a piezo-resistive semiconductor measuring bridge through a remote seal and a transmission liquid. The pressure transmitter converts the pressure values into a load-independent current. A compensation network makes the output signal largely independent of the ambient temperature. As a result of a specially adapted remote seal connection with minimized volume, the influence of the process temperature on the output signal is greatly reduced compared to a conventional screw connection. The pressure transmitters can be powered with a non-regulated DC voltage of 10 to 30 V. Output signals common to measuring technology are available. ■ Technical specifications Installation conditions • Mounting position • Ambient temperature -10 ... +70 °C (14 ... 158 °F) • Storage temperature -10 ... +90 °C (14 ... 194 °F) • Process temperature Max. 200 °C (392 °F), depends on design • Degree of protection (to EN 60529) IP65, optional IP67 • Electromagnetic compatibility - Emitted interference To EN 50081 Part 1, issue 1993 (residential and industrial areas). The unit has no own emissions. - Interference immunity to EN 50082 Part 2, issue March 1995 (industrial areas) Pressure transmitters for food, pharmaceuticals and biotechnology Design Mode of operation Measuring principle Piezo-resistive Input Measured variable Measured range Any, vertical as standard Ambient conditions Gage or absolute pressure 0 ... 160 mbar (0 ... 2.32 psi) ... 0 ... 40 bar (0 ... 580 psi) Weight (without remote seal) • Field housing ≈ 460 g (≈ 1.01 lb) • Housing with plug ≈ 200 g (≈ 0.44 lb) Housing • Designs • Field housing IP65 or IP67, with screwed gland • Angled plug DIN 43650, IP65 • Cable connection, IP67 • Round plug connector M12, IP65 • Material Stainless steel, mat. No. 1.4404/1.4305 Material of union nut Polyamide (with electrical connection using plug or cable) Electronics unit potted with silicone Internal ventilation for measuring ranges < 16 bar (< 232 psi), through housing thread or connection cable depending on design Output Output signal • Two-wire system 4 ... 20 mA • Three-wire system 0 ... 20 mA Measuring accuracy To EN 60770-1 Linearity error including hysteresis (reference point adjustment) ≤ 0.2% of full-scale value Adjustment accuracy ≤ ± 0.2% of full-scale value Adjustment time < 20 ms Influence of ambient temperature On th enclosure • Zero < 0.2%/10 K of full-scale value • Measured span < 0.2%/10 K of full-scale value Process connection On the process connection (remote seal) Zero error (depends on design) • Versions See Ordering data • Material of coupling Stainless steel, mat. No. 1.4404/316L • Flange remote seal - DN 25 / 1" 4.8 mbar/10 K (0.070 psi/10 K) Power supply - DN 32 / 1¼” 2.3 mbar/10 K (0.033 psi/10 K) Terminal voltage on transmitter 10 ... 30 V DC - DN 40 / 1½” 1.6 mbar/10 K (0.023 psi/10 K) Rated voltage 24 V DC - DN 50 / 2" 0.6 mbar/10 K (0.009 psi/10 K) Certificate and approvals - DN 25 / 1" 9.5 mbar/10 K (0.138 psi/10 K) Classification according to pressure equipment directive (DRGL 97/23/EC) - DN 32 / 1¼” 4.1 mbar/10 K (0.060 psi/10 K) • Clamp-on seal - DN 40 / 1½” 3.9 mbar/10 K (0.057 psi/10 K) - DN 50 / 2" 3.9 mbar/10 K (0.057 psi/10 K) The zero error specified for the process connection should be considered as a guideline for a standard design. We will produce a detailed system calculation on request. Systems with reduced remote seal errors are available on request. 2/22 Siemens FI 01 · 2009 For gases of fluid group 1 and liquids of fluid group 1; complies with the requirements of article 3, paragraph 1 (appendix 1); assigned to category III, conformity evaluation module H by the TÜV Nord Explosion protection • Intrinsic safety "i" TÜV 03 ATEX 2099 X - Identification Ex II 2G EEx ib IIC T6 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for food, pharmaceuticals and biotechnology SITRANS P Compact for gage and absolute pressure Selection and Ordering data Order No. Selection and Ordering data Order No. SITRANS P Compact pressure transmitters for pressure and absolute pressure with diaphragm flush at front 7MF 8 0 1 0 - SITRANS P Compact pressure transmitters for pressure and absolute pressure with diaphragm flush at front 7MF 8 0 1 0 - 2-wire system Process temperature up to 140 °C (284 °F) Accuracy: 0.2% of full-scale value Output 4 ... 20 mA 1 7777 - 7777 777 2-wire system Process temperature up to 140 °C (284 °F) Accuracy: 0.2% of full-scale value Output 4 ... 20 mA 1 7777 - 7777 777 Diaphragm seal with quick-release clamp Milk pipe union to DIN 11851 with slotted union nut • DN 25 • DN 32 • DN 40 • DN 50 • DN 65 Milk pipe union to DIN 11851 with threaded socket • DN 25 • DN 32 • DN 40 • DN 50 • DN 65 Clamp connection to DIN 32676 • DN 25 • DN 40 • DN 50 Clamp connection to ISO 2852 • 1 inch • 1½ inch • 2 inch • 2½ inch IDF standard with slotted union nut • 1 inch • 1½ inch • 2 inch IDF standard with threaded socket • 1 inch • 1½ inch • 2 inch SMS standard with slotted union nut • 1 inch • 1½ inch • 2 inch SMS standard with threaded socket • 1 inch • 1½ inch • 2 inch DRD flange, without welding-type flange • DN 50, PN 40 Varivent connection (Tuchenhagen) • D = 50, for Varivent housing DN 25 and 1 inch • D = 68, for Varivent housing DN 40 ... DN 125 and 1½ ... 6 inch Special version (add Order code and plain text) HM HN HP Diaphragm seal with aseptic connection Aseptic screwed gland to DIN 11864-1, form A, with slotted union nut • 1 inch • 1½ inch • 2 inch • 2½ inch Aseptic screwed gland to DIN 11864-1, form A with threaded socket • 1 inch • 1½ inch • 2 inch • 2½ inch Aseptic screwed NEUMO with slotted union nut1) • DN 25 • DN 32 • DN 40 • DN 50 Aseptic screwed NEUMO with threaded socket1) • DN 25 • DN 32 • DN 40 • DN 50 Aseptic screwed NEUMO with clamp connection, form R1) • DN 25 • DN 32 • DN 40 • DN 50 Aseptic screwed NEUMO with clamp connection, form V1) • DN 25 • DN 32 • DN 40 • DN 50 Special version (add Order code and plain text) JH Filling liquid Vegetable oil 1 medicinal white oil 2 Food oil, FDA-listed 3 Special version (add Order code and plain text) 9 AD AE AF AG AH BD BE BF BG BH CD CF CG DM DN DP DQ EM EN EP FM FN FP GM GN GP KF KL ZA J1Y Filling liquid Vegetable oil 1 medicinal white oil 2 Food oil, FDA-listed 3 Special version (add Order code and plain text) 9 Output signal 4 ... 20 mA Special version (add Order code and plain text) Ord. code Output signal 4 ... 20 mA L1Y PM PN PP PQ QM QN QP QQ RD RE RF RG SD SE SF SG TD TE TF TG UD UE UF UG ZA J1Y L1Y 1 9 Special version (add Order code and plain text) 1) Ord. code M1 Y Please specify as well: Connections for pipes: R01, R02 or R03, see table "Further designs" on next page 1 9 M1 Y Siemens FI 01 · 2009 2/23 2 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for food, pharmaceuticals and biotechnology SITRANS P Compact for gage and absolute pressure 2 Selection and Ordering data Order No. Selection and Ordering data Order No. SITRANS P Compact pressure transmitters for pressure and absolute pressure with diaphragm flush at front 7MF 8 0 1 0 - SITRANS P Compact pressure transmitters for pressure and absolute pressure with diaphragm flush at front 7MF 8 0 1 0 - 2-wire system Process temperature up to 140 °C (284 °F) Accuracy: 0.2% of full-scale value Output 4 ... 20 mA 1 7777 - 7777 777 2-wire system Process temperature up to 140 °C (284 °F) Accuracy: 0.2% of full-scale value Output 4 ... 20 mA 1 7777 - 7777 777 Housing design (stainless steel mat. No. 1.4404/316L) / electr. connection Housing with angled plug to DIN 43650, IP65 Ord. code Measured range 1 Housing with round plug M12, IP65, union nut made of polyamide 2 Housing with round plug M12, IP65, union nut made of stainless steel 3 Stainless steel field housing (small) with cable gland, IP65 4 Stainless steel field housing (small) with cable gland, IP67 Internal ventilation for measuring ranges < 10 bar (< 145 psi) 5 GA -1 ... 9 bar g 30 bar g (-14.5 ... 130.5 psi g) (435 psi g) -1 ... 15 bar g 50 bar g (-14.5 ... 217.6 psi g) (725 psi g) GB 0 ... 1 bar a (0 ... 14.5 psi a) 0 ... 1.6 bar a (0 ... 23.2 psi a) 0 ... 2.5 bar a (0 ... 36.3 psi a) 0 ... 4 bar a (0 ... 58 psi a) 0 ... 6 bar a (0 ... 87 psi a) 10 bar a (145 psi a) 10 bar a (145 psi a) 16 bar a (232 psi a) 16 bar a (232 psi a) 30 bar a (435 psi a) F) HA F) HB F) HC F) HD F) HE BC 0 ... 10 bar a (0 ... 145 psi a) 30 bar a (435 psi a) F) JA BD Special version (add Order code and plain text) F) ZA BE Explosion protection without with, to ATEX 100a, II 2 G, EEx ib IIC T6 Overload pressure 2 bar g (29 psi g) 2 bar g (29 psi g) 6 bar g (87 psi g) 6 bar g (87 psi g) 0 ... 1 bar g (0 ... 14.5 psi g) 0 ... 1.6 bar g (0 ... 23.2 psi g) 0 ... 2.5 bar g (0 ... 36.3 psi g) 0 ... 4 bar g (0 ... 58 psi g) 0 ... 6 bar g (0 ... 87 psi g) 10 bar g (145 psi g) 10 bar g (145 psi g) 16 bar g (232 psi g) 16 bar g (232 psi g) 30 bar g (435 psi g) CA 0 ... 10 bar g (0 ... 145 psi g) 0 ... 16 bar g (0 ... 232 psi g) 0 ... 25 bar g (0 ... 363 psi g) 0 ... 40 bar g (0 ... 580 psi g) 30 bar g (435 psi g) 50 bar g (725 psi g) 50 bar g (725 psi g) 70 bar g (1015 psi g) DA -160 ... 0 mbar g (-2.32 ... 0 psi g) -250 ... 0 bar g (-3.73 ... 0 psi g) -400 ... 0 bar g (-5.8 ... 0 psi g) -600 ... 0 bar g (-8.7 ... 0 psi g) -1 ... 0 bar g (-14.5 ... 0 psi g) -1 ... 0.6 bar g (-14.5 ... 8.7 psi g) -1 ... 1.5 bar g (-14.5 ... 21.8 psi g) -1 ... 3 bar g (-14.5 ... 43.5 psi g) -1 ... 5 bar g (-14.5 ... 72.5 psi g) 2 bar g (29 psi g) 2 bar g (29 psi g) 6 bar g (87 psi g) 6 bar g (87 psi g) 10 bar g (145 psi g) 10 bar g (145 psi g) 16 bar g (232 psi g) 16 bar g (232 psi g) 30 bar g (435 psi g) EB Siemens FI 01 · 2009 Overload pressure (continued) Measured range 0 ... 160 mbar g (0 ... 2.32 psi g) 0 ... 250 mbar g (0 ... 3.63 psi g) 0 ... 400 mbar g (0 ... 5.8 psi g) 0 ... 600 mbar g (0 ... 8.7 psi g) 2/24 Ord. code BB CB CC CD CE DB DC DD EC ED EE FA FB FC FD FE Further designs 1 2 Order code Please add "-Z" to Order No. and specify Order code Hygiene version Roughness of process connection: Foil Ra < 0.8 μm (3.15·10-8 inch); Welded seams Ra < 1.5 μm (5.9·10-8 inch) P01 Integral cooling element Process temperature max. 200 °C (392 °F) instead of 140 °C (284 °F) K01 Connections for pipe Pipes to DIN 11850 ISO pipes to DIN 2463 Pipes to O. D. Tubing "BS 4825 Part 1" Certificates Quality inspection certificate (Factory calibration) to IEC 60770-2 P1Y R01 R02 R03 C11 Acceptance test certificate to EN 10204-3.1 Use of FDA-listed remote seal filling liquids certified by factory certificate to EN 10204-2.2 C12 Roughness depth measurement Ra certified by factory certificate to EN 10204-3.1 C18 Certification to EHEDG for clamp-on seals with aseptic screwed gland to DIN 11864 C19 C17 F) Subject to export regulations AL: 9I999, ECCN: N. © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for food, pharmaceuticals and biotechnology SITRANS P Compact for gage and absolute pressure Selection and Ordering data Order No. Selection and Ordering data Order No. SITRANS P Compact pressure transmitters for pressure and absolute pressure with clamp-on remote seal 7MF 8 0 1 0 - SITRANS P Compact pressure transmitters for pressure and absolute pressure with clamp-on remote seal 7MF 8 0 1 0 - 2-wire system Process temperature up to 140 °C (284 °F) Accuracy: 0.2% of full-scale value Output 4 ... 20 mA 2 7777 - 7777 777 2-wire system Process temperature up to 140 °C (284 °F) Accuracy: 0.2% of full-scale value Output 4 ... 20 mA 2 7777 - 7777 777 Clamp-on remote seal (screwed gland at both ends) with quick-release clamps Milk pipe union to DIN 11851 with threaded socket • DN 25 • DN 32 • DN 40 • DN 50 • DN 65 Clamp connection to DIN 32676 • DN 25 • DN 32 • DN 40 • DN 50 • DN 65 Clamp connection to ISO 28521) • 1 inch • 1½ inch • 2 inch • 2½ inch Special version (add Order code and plain text) AD AE AF AG AH CD CE CF CG CH DM DN DP DQ ZA J1Y Filling liquid Vegetable oil 1 Medicinal white oil 2 Food oil, FDA-listed 3 Special version (add Order code and plain text) 9 Output signal 4 ... 20 mA Special version (add Order code and plain text) 1) Ord. code L1Y 1 9 M1 Y Please note the internal diameter of the pipe. Please specify pipe classes (see "Further designs") Clamp-on seal with aseptic connection Aseptic screwed gland to DIN 11864-1, form A with threaded socket • 1 inch • 1½ inch • 2 inch Aseptic screwed NEUMO with threaded socket1) • DN 25 • DN 32 • DN 40 • DN 50 • DN 65 Aseptic screwed NEUMO with clamp connection, form R1) • DN 25 • DN 32 • DN 40 • DN 50 Aseptic screwed gland SÜDMO with threaded socket W 501 • 1 inch • 1½ inch • 2 inch Aseptic screwed gland SÜDMO with clamp connection W 601 • 1 inch • 1½ inch • 2 inch Special version (add Order code and plain text) QM QN QP SD SE SF SG SH TD TE TF TG VM VN VP WM WN WP ZA J1Y Filling liquid Vegetable oil 1 medicinal white oil 2 Food oil, FDA-listed 3 Special version (add Order code and plain text) 9 Output signal 4 ... 20 mA L1Y 1 9 Special version (add Order code and plain text) 1) Ord. code M1 Y Please specify as well: Connections for pipes: R01, R02 or R03, see table "Further designs" on next page Siemens FI 01 · 2009 2/25 2 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for food, pharmaceuticals and biotechnology SITRANS P Compact for gage and absolute pressure 2 Selection and Ordering data Order No. Selection and Ordering data Order No. SITRANS P Compact pressure transmitters for pressure and absolute pressure with clamp-on remote seal 7MF 8 0 1 0 - SITRANS P Compact pressure transmitters for pressure and absolute pressure with clamp-on remote seal 7MF 8 0 1 0 - 2-wire system Process temperature up to 140 °C (284 °F) Accuracy: 0.2% of full-scale value Output 4 ... 20 mA 2 7777 - 7777 777 2-wire system Process temperature up to 140 °C (284 °F) Accuracy: 0.2% of full-scale value Output 4 ... 20 mA 2 7777 - 7777 777 Housing design (stainless steel mat. No. 1.4404/316L) / electr. connection Housing with angled plug to DIN 43650, IP65, union nut made of polyamide Housing with round plug M12, IP65, union nut made of polyamide Housing with round plug M12, IP65, union nut made of stainless steel Ord. code Measured range (continued) 1 3 Stainless steel field housing (small) with cable gland, IP65 4 Stainless steel field housing (small) with cable gland, IP67 Internal ventilation for measuring ranges < 10 bar (< 145 psi) 5 GB F) HA F) HB F) HC F) HD F) HE BB 10 bar a (145 psi a) 10 bar a (145 psi a) 16 bar a (232 psi a) 16 bar a (232 psi a) 30 bar a (435 psi a) BC 0 ... 10 bar a (0 ... 145 psi a) 30 bar a (435 psi a) F) JA BD Special version (add Order code and plain text) F) ZA BE Explosion protection without with, to ATEX 100a, II 2 G, EEx ib IIC T6 Overload pressure 2 bar g (29 psi g) 2 bar g (29 psi g) 6 bar g (87 psi g) 6 bar g (87 psi g) 0 ... 1 bar g (0 ... 14.5 psi g) 0 ... 1.6 bar g (0 ... 23.2 psi g) 0 ... 2.5 bar g (0 ... 36.3 psi g) 0 ... 4 bar g (0 ... 58 psi g) 0 ... 6 bar g (0 ... 87 psi g) 10 bar g (145 psi g) 10 bar g (145 psi g) 16 bar g (232 psi g) 16 bar g (232 psi g) 30 bar g (435 psi g) CA 0 ... 10 bar g (0 ... 145 psi g) 0 ... 16 bar g (0 ... 232 psi g) 0 ... 25 bar g (0 ... 363 psi g) 0 ... 40 bar g (0 ... 580 psi g) 30 bar g (435 psi g) 50 bar g (725 psi g) 50 bar g (725 psi g) 70 bar g (1015 psi g) DA -160 ... 0 mbar g (-2.32 ... 0 psi g) -250 ... 0 bar g (-3.73 ... 0 psi g) -400 ... 0 bar g (-5.8 ... 0 psi g) -600 ... 0 bar g (-8.7 ... 0 psi g) -1 ... 0 bar g (-14.5 ... 0 psi g) -1 ... 0.6 bar g (-14.5 ... 8.7 psi g) -1 ... 1.5 bar g (-14.5 ... 21.8 psi g) -1 ... 3 bar g (-14.5 ... 43.5 psi g) -1 ... 5 bar g (-14.5 ... 72.5 psi g) 2 bar g (29 psi g) 2 bar g (29 psi g) 6 bar g (87 psi g) 6 bar g (87 psi g) 10 bar g (145 psi g) 10 bar g (145 psi g) 16 bar g (232 psi g) 16 bar g (232 psi g) 30 bar g (435 psi g) EB Siemens FI 01 · 2009 GA 0 ... 1 bar a (0 ... 14.5 psi a) 0 ... 1.6 bar a (0 ... 23.2 psi a) 0 ... 2.5 bar a (0 ... 36.3 psi a) 0 ... 4 bar a (0 ... 58 psi a) 0 ... 6 bar a (0 ... 87 psi a) Measured range 0 ... 160 mbar g (0 ... 2.32 psi g) 0 ... 250 mbar g (0 ... 3.63 psi g) 0 ... 400 mbar g (0 ... 5.8 psi g) 0 ... 600 mbar g (0 ... 8.7 psi g) 2/26 Overload pressure -1 ... 9 bar g 30 bar g (-14.5 ... 130.5 psi g)(435 psi g) -1 ... 15 bar g 50 bar g (-14.5 ... 217.6 psi g)(725 psi g) 2 Ord. code CB CC CD CE DB DC DD EC ED EE FA FB FC FD Further designs 1 2 Order code Please add "-Z" to Order No. and specify Order code Hygiene version Roughness of process connection: Foil Ra < 0.8 μm (3.15·10-8 inch); Welded seams Ra < 1.5 μm (5.9·10-8 inch) P01 Integral cooling element Process temperature max. 200 °C (392 °F) instead of 140 °C (284 °F) K01 Connections for pipe Pipes to DIN 11850 ISO pipes to ISO 2463 Pipes to O. D. Tubing "BS 4825 Part 1" Certificates Quality inspection certificate (Factory calibration) to IEC 60770-2 R01 R02 R03 C11 Acceptance test certificate to EN 10204-3.1 Use of FDA-listed remote seal filling liquids certified by factory certificate to EN 10204-2.2 C12 Roughness depth measurement Ra certified by factory certificate to EN 10204-3.1 C18 Certification to EHEDG for clamp-on seals with aseptic screwed gland to DIN 11864 C19 C17 F) Subject to export regulations AL: 9I999, ECCN: N. FE P1Y © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for food, pharmaceuticals and biotechnology SITRANS P Compact for gage and absolute pressure ■ Dimensional drawings Housing Round plug with screw connection M12 Degree of protection IP65 2 For cable diam. 4 ... 10 (0.18 ... 0.39) 94 (3.7) 74,5 (2.93) 107,5 (4.23) 30 (1.18) 9 (0.35) 22,5 (0.9) » 132 (5.2) 38,5 (1.52) 74,5 (2.93) 124,5 (4.9) 74,5 (2.93) » 50 (1.97) 39 (1.53) » 8 (0.3) For cable diam. 4.5 ... 10 (0.18 ... 0.39) ø 50 (diam. 1.97) Cable connection Degree of protection IP67 (cable ventilation) Angled plug to DIN 43 650 Degree of protection IP65 74,5 (2.93) Fieldhousing stainless steel Degree of protection IP65 IP67 as alternative Thermal decoupler for process temperature up to 200 °C (392 °F) Process connections Standard Food screwed gland Union nut to DIN 11 851 DN 25 ... 65 Clamp connection to DIN 32 676 ISO 2852 DN 25 ... 65 1 ... 2½ Pipe-screwed gland (food) Round thread to DIN 11 851 DN 25 ... 65 Pipe clamp connection to DIN 32 676 DN 25 ... 100 to ISO 2853 1 ... 2½ Clamp connection Neumo, Südmo, Guth DN 25 ... 50 1 ... 2 Pipe screwed gland (aseptic) Round thread DIN 11 864-1 Neumo, Südmo, Guth DN 25 ... 65 1 ... 2 Pipe clamp connection Neumo, Südmo, Guth DN 25 ... 65 1 ... 2 Aseptic Aseptic screwed gland Round thread Neumo, Südmo, Guth DIN 11 864-1 DN 25 ... 65 1 ... 2 SITRANS P, dimensions in mm (inch) ■ Schematics Field housing Angled plug Cable connection 0V 0V brown yellow green Two-wire system 24 V 24 V Round plug 4 black 1 brown 2 white SITRANS P Compact, connection diagram Siemens FI 01 · 2009 2/27 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for food, pharmaceuticals and biotechnology SITRANS P300 for gage and absolute pressure ■ Overview 2 The SITRANS P300 is a digital pressure transmitter for gage and absolute pressure. All conventional thread versions are available as process connections. In addition, various hygiene-based connections and flange connections with front-flush diaphragms meet the requirements of a dead space free process connection. The output signal is a load-independent direct current from 4 to 20 mA or a PROFIBUS PA signal, which is linearly proportional to the input pressure. Communication is over HART protocol or over PROFIBUS PA interface. Convenient buttons for easy local operation of the basic settings of the pressure transmitter. The SITRANS P300 has a single-chamber stainless steel casing. The pressure transmitter is approved with "intrinsically safe" type of protection It can be used in zone 1 or zone 0. With appropriate parameter settings, it can also be used for the following additional measurement types: • Level • Volume • Mass The "intrinsically-safe" EEx version of the transmitter can be installed in hazardous areas (zone 1). The transmitters are provided with an EC type examination certificate and comply with the respective harmonized European standards of ATEX. Gage pressure ■ Benefits • High quality and long life • High reliability even under extreme chemical and mechanical loads • Extensive diagnosis and simulation functions • Minimum conformity error • Small long-term drift • Wetted parts made of high-grade materials (such as stainless steel, Hastelloy) • Measuring range 8 mbar to 400 bar • High measuring accuracy • Parameterization over control keys and HART communication or PROFIBUS PA communication ■ Application The pressure transmitter is available in versions for gage pressure and for absolute pressure. The output signal is always a load-independent direct current from 4 to 20 mA or a PROFIBUS PA signal, which is linearly proportional to the input pressure. The pressure transmitter measures aggressive, nonaggressive and hazardous gases, as well as vapors and liquids. 2/28 It can be used for the following measurement types: • Gage pressure • Absolute pressure Siemens FI 01 · 2009 This variant measures aggressive, non-aggressive and hazardous gases, vapors and liquids. The smallest measuring span is 10 mbar g, the largest 400 bar g. Level With appropriate parameter settings, the gage pressure variant measures the level of aggressive, non-aggressive and hazardous liquids. For measuring the level in an open container you require one device; for measuring the level in a closed container, you require two devices and a process control system. Absolute pressure This variant measures the absolute pressure of aggressive, nonaggressive and hazardous gases, vapors and liquids. The smallest measuring span is 8 mbar a, the largest 30 bar a. © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for food, pharmaceuticals and biotechnology SITRANS P300 for gage and absolute pressure ■ Design The device comprises: • Electronics • Housing • Measuring cell ■ Function Operation of the electronics with HART communication 9 8 2 2 0 0 00 0 00 M 10 5 4 3 mC IA, UH 7 HART interface EEPROM 6 Electronics 1 Sensor Pe Perspective view of the SITRANS P300 The housing has a screw-on cover (3), with or without an inspection window depending on the version. The electrical terminal housing, the buttons for operation of the device and, depending on the version, the digital display are located under this cover. The connections for the auxiliary power UH and the shield are in the terminal housing. The cable gland is mounted on the side of the housing. The measuring cell with the process connection (5) is located on the underside of the housing. Depending on the version of the device, the measuring cell with the process connection may differ from the one shown in the diagram. 1 2 3 4 5 6 7 8 9 10 IA UH Pe EEPROM 6 Measuring cell Measuring cell sensor Instrument amplifier Analog-to-digital converter Microcontroller Digital-to-analog converter One non-volatile memory each in the measuring cell and electronics HART interface Three input keys (local operation) Digital display Diode circuit and connection for external ammeter Output current Power supply Input variable Function diagram of electronics The input pressure is converted into an electrical signal by the sensor (1). This signal is amplified by the measuring amplifier (2) and digitalized in an analog to digital converter (3). The digital signal is analyzed in a microcontroller (4) and corrected with regard to linearity and thermal characteristics. In a digital to analog converter (5) it is then converted into the output current of 4 to 20 mA. A diode circuit provides reverse voltage protection. You can make an uninterrupted current measurement with a lowohm ammeter at the connection (10). The data specific to the measuring cell, the electronic data and parameter settings are stored in two non-volatile memories (6). The first memory is linked with the measuring cell, the second with the electronics. The buttons (8) can be used to call up individual functions, socalled modes. If you have a device with a digital display (9), you can use this to track mode settings and other messages. The basic mode settings can be changed with a computer via the HART modem (7). Siemens FI 01 · 2009 2/29 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for food, pharmaceuticals and biotechnology SITRANS P300 for gage and absolute pressure Operation of the electronics with PROFIBUS PA communication 9 3 4 5 mC EEPROM 6 Electronics 1 6 pe 7 Power supply unit Coupler 11 12 5 EEPROM 1 pe Input variable Power supply unit 6 6 pe 9 10 11 12 Power supply 10 Electronics BusMaster Three input keys (local operation) Digital display Power supply DP/PA coupler or link Bus master 7 FF interface Coupler Sensor 8 4 Power supply 10 Measuring cell Measuring cell sensor Instrument amplifier Analog-to-digital converter Microcontroller Electrical isolation One non-volatile memory each in the measuring cell and electronics PROFIBUS-PA interface 3 mC EEPROM Sensor 1 2 3 4 5 6 2 7 PA interface PROFIBUS-DP 2 0 0 00 0 00 M PROFIBUS-PA M 9 8 0 0 00 0 00 1 2 3 4 5 6 7 EEPROM 8 2 Mode of operation of the FOUNDATION Fieldbus electronics Measuring cell Measuring cell sensor Instrument amplifier Analog-to-digital converter Microcontroller Electrical isolation One non-volatile memory each in the measuring cell and electronics FF interface 8 9 10 Three input keys (local operation) Digital display Power supply pe Input variable Function diagram of electronics Function diagram of electronics The input pressure is converted into an electrical signal by the sensor (1). This signal is amplified by the measuring amplifier (2) and digitalized in an analog to digital converter (3). The digital signal is analyzed in a microcontroller (4) and corrected with regard to linearity and thermal characteristics. It is then made available at the PROFIBUS PA over an electrically isolated PROFIBUS PA interface (7). The data specific to the measuring cell, the electronic data and parameter settings are stored in two non-volatile memories (6). The first memory is linked with the measuring cell, the second with the electronics. The bridge output voltage created by the sensor (1, Figure "Function diagram of electronics") is amplified by the instrument amplifier (2) and digitized in the analog-to-digital converter (3). The digital information is evaluated in the microcontroller, its linearity and temperature response corrected, and provided on the FOUNDATION Fieldbus through an electrically isolated FOUNDATION Fieldbus Interface (7). The buttons (8) can be used to call up individual functions, socalled modes. If you have a device with a digital display (9), you can use this to track mode settings and other messages. The basic mode settings can be changed with a computer over the bus master (12). The data specific to the measuring cell, the electronics data, and the parameter data are stored in the two non-volatile memories (6). The one memory is coupled to the measuring cell, the other to the electronics. As the result of this modular design, the electronics and the measuring cell can be replaced separately from each other. Using the three input keys (8) you can parameterize the pressure transmitter directly at the point of measurement. The input keys can also be used to control the view of the results, the error messages and the operating modes on the digital display (9). The results with status values and diagnostic values are transferred by cyclic data transmission on the FOUNDATION Fieldbus. Parameterization data and error messages are transferred by acyclic data transmission. Special software such as National Instruments Configurator is required for this. Mode of operation of the measuring cells The process connections available include the following: • G½ • ½-14 NPT • Front-flush diaphragm: - Flanges to EN - Flanges to ASME - NuG and pharmaceutical connections 2/30 Siemens FI 01 · 2009 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for food, pharmaceuticals and biotechnology SITRANS P300 for gage and absolute pressure Measuring cell for gage pressure Measuring cell for gage pressure, front-flush diaphragm 1 1 6 5 5 2 4 2 4 3 pe 1 2 3 4 5 6 pe Reference pressure Measuring cell Process connection Seal diaphragm Filling liquid Relative pressure sensor Pressure as input variable Measuring cell for gage pressure, function chart The input pressure (pe) is transferred to the gage pressure sensor (6) via the seal diaphragm (4) and the filling liquid (5), displacing its measuring diaphragm. The displacement changes the resistance value of the four piezo resistors in the measuring diaphragm in a bridge circuit. The change in the resistance causes a bridge output voltage proportional to the input pressure. The transmitters with spans ≤ 63 bar measure the input pressure against atmosphere, those with spans ≥ 160 bar against vacuum. Measuring cell for absolute pressure 1 2 3 4 5 pe Reference pressure Measuring cell Seal diaphragm Filling liquid Relative pressure sensor Pressure as input variable 3 SH Measuring cell for gage pressure, front-flush diaphragm, function chart The input pressure (pe) is transferred to the gage pressure sensor (6) via the seal diaphragm (4) and the filling liquid (5), displacing its measuring diaphragm. The displacement changes the resistance value of the four piezo resistors in the measuring diaphragm in a bridge circuit. The change in the resistance causes a bridge output voltage proportional to the input pressure. The transmitters with spans ≤ 63 bar measure the input pressure against atmosphere, those with spans ≥ 160 bar against vacuum. Measuring cell for absolute pressure, front-flush diaphragm 1 5 4 4 3 1 2 pe 1 2 3 4 5 pe 3 Measuring cell Process connection Seal diaphragm Filling liquid Absolute pressure sensor Pressure as input variable Measuring cell for absolute pressure, function chart The input pressure (pe) is transferred to the absolute pressure sensor (5) via the seal diaphragm (3) and the filling liquid (4), displacing its measuring diaphragm. The displacement changes the resistance value of the four piezo resistors in the measuring diaphragm in a bridge circuit. The change in the resistance causes a bridge output voltage proportional to the input pressure. 1 2 3 4 pe Measuring cell Seal diaphragm Filling liquid Absolute pressure sensor Pressure as input variable 2 SH Measuring cell for absolute pressure, front-flush diaphragm, function chart Siemens FI 01 · 2009 2/31 2 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for food, pharmaceuticals and biotechnology SITRANS P300 for gage and absolute pressure 2 The input pressure (pe) is transferred to the absolute pressure sensor (5) via the seal diaphragm (3) and the filling liquid (4), displacing its measuring diaphragm. The displacement changes the resistance value of the four piezo resistors in the measuring diaphragm in a bridge circuit. The change in the resistance causes a bridge output voltage proportional to the input pressure. Adjustable parameters on SITRANS P300 with HART communication Parameters Input keys HART communication Start of scale x x Full-scale value x x Parameterization of SITRANS P300 Electrical damping x x Depending on the version, there are a range of options for parameterizing the pressure transmitter and for setting or scanning the parameters. Start-of-scale value without application of a pressure ("Blind setting") x x Full-scale value without application of a x pressure ("Blind setting") x Parameterization using the input keys (local operation) With the input keys you can easily set the most important parameters without any additional equipment. Parameterization using HART communication Parameterization using HART communication is performed with a HART communicator or a PC. + 230 ... 1100 W SITRANS P transmitter Power supply HART communicator Communication between a HART communicator and a pressure transmitter When parameterizing with the HART communicator, the connection is made directly to the 2-wire system. 230 ... 500 W SITRANS P transmitter Power supply PC or laptop HART modem RS 232 Zero adjustment x x Current transmitter x x Fault current x x Disabling of keys, write protection x x1) Type of dimension and actual dimension x x Input of characteristic x Freely-programmable LCD x Diagnostics functions x 1) Cancel apart from write protection Diagnostic functions for SITRANS P300 with HART communication • Zero correction display • Event counter • Limit transmitter • Saturation alarm • Slave pointer • Simulation functions • Maintenance timer Available physical units of display for SITRANS P300 with HART communication Physical variable Physical dimensions Pressure (setting can also be made in the factory) Pa, MPa, kPa, bar, mbar, torr, atm, psi, g/cm2, kg/cm2, inH2O, inH2O (4 °C), mmH2O, ftH2O (20 °C), inHg, mmHg Level (height data) m, cm, mm, ft, in Volume m3, dm3, hl, yd3, ft3, in3, US gallon, lmp. gallon, bushel, barrel, barrel liquid Mass g, kg, t, lb, Ston, Lton, oz HART communication between a PC communicator and a pressure transmitter When parameterizing with a PC, the connection is made through a HART modem. The signals needed for communication in conformity with the HART 5.x or 6.x protocols are superimposed on the output current using the Frequency Shift Keying (FSK) method. 2/32 Siemens FI 01 · 2009 Temperature K, °C, °F, °R Miscellaneous %, mA © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for food, pharmaceuticals and biotechnology SITRANS P300 for gage and absolute pressure Parameterization through PROFIBUS PA interface Hygiene version Fully digital communication through PROFIBUS PA, profile 3.0, is particularly user-friendly. The PROFIBUS puts the DS III PA is in connection with a process control system, e.g. SIMATIC PSC 7. Communication is possible even in a potentially explosive environment. In the case of the SITRANS P300 with 7MF812.-... front-flush diaphragm, selected connections comply with the requirements of the EHEDG or 3A. You will find further details in the order form. Please note in particular that the seal materials used must comply with the requirements of 3A. Similarly, the filling liquids used must be FDA-compliant. For parameterization through PROFIBUS you need suitable software, e.g. SIMATIC PDM (Process Device Manager). Parameterization through FOUNDATION Fieldbus Interface Fully digital communication through FOUNDATION Fieldbus is particularly user-friendly. Through the FOUNDATION Fieldbus the P300 FF is connected to a process control system. Communication is possible even in a potentially explosive environment. For parameterization through the FOUNDATION Fieldbus you need suitable software, e.g. National Instruments Configurator. Adjustable parameters for P300 PA and FF Parameters Input keys PROFIBUS PA and (DS III HART) FOUNDATION Fieldbus interface Electrical damping x x Zero adjustment (correction of x position) x Key and/or function disabling x x Source of measured-value dis- x play x Physical dimension of display x x Position of decimal point x x Bus address x x Adjustment of characteristic x x Input of characteristic x Freely-programmable LCD x Diagnostics functions x Diagnostic functions for P300 PA and FF • Event counter • Slave pointer • Maintenance timer • Simulation functions • Display of zero correction • Limit transmitter • Saturation alarm Physical dimensions available for the display Physical variable Physical dimensions Pressure (setting can also be made in the factory) MPa, kPa, Pa, bar, mbar, torr, atm, psi, g/cm2, kg/cm2, mmH2O, mmH2O (4 °C), inH2O, inH20 (4 °C), ftH2O (20 °C), mmHg, inHg Level (height data) m, cm, mm, ft, in, yd Volume m3, dm3, hl, yd3, ft3, in3, US gallon, lmp. gallon, bushel, barrel, barrel liquid Volume flow m3/s, m3/min, m3/h, m3/d, l/s, l/min, l/h, l/ d, Ml/d, ft3/s, ft3/min, ft3/h, ft3/d, US gallon/s, US gallon/min, US gallon/h, US gallon/d, bbl/s, bbl/min, bbl/h, bbl/d Mass flow g/s, g/min, g/h, g/d, kg/s, kg/min, kg/h, kg/d, t/s, t/min, t/h, /t/d, lb/s, lb/min, lb/h, lb/d, STon/s, STon/min, STon/h, STon/d, LTon/s, LTon/min, LTon/h, LTon/d Total mass flow t, kg, g, lb, oz, LTon, STon Temperature K, °C, °F, °R Miscellaneous % Siemens FI 01 · 2009 2/33 2 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for food, pharmaceuticals and biotechnology SITRANS P300 for gage and absolute pressure ■ Technical specifications F SITRANS P300 for gage pressure and absolute pressure HART 2 PROFIBUS PA and FOUNDATION Fieldbus Gage pressure input Measured variable Gage pressure Spans (infinitely adjustable) or nominal measuring range and max. pemissible test pressure Span Max. perm. test pressure Nominal measuring range Max. perm. test pressure 0.01 ... 1 bar g (0.15 ... 14.5 psi g) 6 bar g (87 psi g) 1 bar g (14.5 psi g) 6 bar g (87 psi g) 0.04 ... 4 bar g (0.58 ... 58 psi g) 10 bar g (145 psi g) 4 bar g (58 psi g) 10 bar g (145 psi g) 0.16 ... 16 bar g (2.3 ... 232 psi g) 32 bar g (464 psi g) 16 bar g (232 psi g) 32 bar g (464 psi g) 0.6 ... 63 bar g (9.1 ... 914 psi g) 100 bar g (1450 psi g) 63 bar g (914 psi g) 100 bar g (1450 psi g) 1.6 ... 160 bar g (23.2 ... 2321 psi g) 250 bar g (3626 psi g) 160 bar g (2321 psi g) 250 bar g (3626 psi g) 4.0 ... 400 bar g (58 ... 5802 psi g) 600 bar g (8700 psi g) 400 bar g (5802 psi g) 600 bar g (8700 psi g) Depending on the process connection, the span may differ from these values Depending on the process connection, the nominal measuring range may differ from these values Lower measuring limit • Measuring cell with silicone oil 30 mbar a (0.44 psi a) Upper measuring limit • Measuring cell with silicone oil 100% of max. span 100% of the max. nominal measuring range Absolute pressure input Measured variable Absolute pressure Spans (infinitely adjustable) or nominal measuring range and max. pemissible test pressure Span Max. perm. test pressure Nominal measuring range Max. perm. test pressure 8 ... 250 mbar a (0.12 ... 3.6 psi a) 6 bar a (87 psi a) 250 mbar a (3.6 psi a) 6 bar a (87 psi a) 0.043 ... 1.30 bar a (0.62 ... 19 psi a) 10 bar a (145 psi a) 1.30 bar a (19 psi a) 10 bar a (145 psi a) 0.16 ... 5 bar a (2.3 ... 73 psi a) 30 bar a (435 psi a) 5 bar a (73 psi a) 30 bar a (435 psi a) 1 ... 30 bar a (14.5 ... 435 psi a) 100 bar a (1450 psi a) 30 bar a (435 psi a) 100 bar a (1450 psi a) Lower measuring limit • Measuring cell with silicone oil 0 mbar a (0 psi a) Upper measuring limit • Measuring cell with silicone oil 100% of max. span 100% of the max. nominal measuring range Input of gage pressure, with front-flush diaphragm Measured variable Gage pressure, front-flush Spans (infinitely adjustable) or nominal measuring range and max. pemissible test pressure Span Max. perm. test pressure Nominal measuring range Max. perm. test pressure 0.01 ... 1 bar g (0.145 ... 14.5 psi g) 6 bar g (87 psi g) 1 bar g (14.5 psi g) 6 bar g (87 psi g) 0.04 ... 4 bar g (0.58 ... 58 psi g) 10 bar g (145 psi g) 4 bar g (58 psi g) 10 bar g (145 psi g) 0.16 ... 16 bar g (2.32 ... 232 psi g) 32 bar g (464 psi g) 16 bar g (232 psi g) 32 bar g (464 psi g) 0.6 ... 63 bar g (9.14 ... 914 psi g) 100 bar g (1450 psi g) 63 bar g (914 psi g) 100 bar g (1450 psi g) Lower measuring limit -100 mbar g (-1.45 psi g) Upper measuring limit • Measuring cell with silicone oil 2/34 Siemens FI 01 · 2009 100% of max. span 100% of the max. nominal measuring range © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for food, pharmaceuticals and biotechnology SITRANS P300 for gage and absolute pressure SITRANS P300 for gage pressure and absolute pressure HART PROFIBUS PA and FOUNDATION Fieldbus Input of absolute pressure, with front-flush diaphragm Measured variable Absolute pressure (front-flush) Spans (infinitely adjustable) or nominal measuring range and max. pemissible test pressure Span Max. perm. test pressure Nominal measuring range Max. perm. test pressure 43 ... 1300 mbar a (0.62 ... 18.9 psi a) 10 bar a (145 psi a) 1300 mbar a (18.9 psi a) 10 bar a (145 psi a) 0.16 ... 5 bar a (2.32 ... 72.5 psi a) 30 bar a (435 psi a) 5 bar a (72,5 psi a) 30 bar a (435 psi a) 1 ... 30 bar a (14.5 ... 435 psi a) 100 bar a (1450 psi a) 30 bar a (435 psi a) 100 bar a (1450 psi a) Depending on the process connection, the span may differ from these values Lower measuring limit Depending on the process connection, the nominal measuring range may differ from these values 0 bar a (0 psi a) Upper measuring limit • Measuring cell with silicone oil 100% der max. Messspanne 100% des max. Nennmessbereichs Output signal 4 ... 20 mA Digital PROFIBUS PA signal Physical bus - IEC 61158-2 With polarity reversal protection No Yes Electrical damping T63 (step width 0.1 s) Set to 0.1 s (0 ... 100 s) Accuracy To EN 60770-1 Reference conditions (All error data refer always refer to the set span) Increasing characteristic, start-of-scale value 0 bar, stainless steel seal diaphragm, measuring cell with silicone oil, room temperature 25 °C (77 °F), span ratio (r = max. span / set span) Output Measurement deviation with cut-off point setting, including hysteresis and repeatability. Gage pressure Absolute pressure (Absolute pressure, frontflushed) Linear characteristic curve • r ≤ 10 ≤ (0.0029 ⋅ r + 0.071)% ≤ 0,1% ≤ 0,2% • 10 < r ≤ 30 ≤ (0.0045 ⋅ r + 0.071)% ≤ 0,2% ≤ 0,4% - - • 30 < r ≤ 100 ≤ (0.005 ⋅ r + 0.05)% Settling time T63 without electrical damping Approx. 0.2 s Long-term drift at ± 30 °C (± 54 °F) ≤ (0.25 ⋅ r)%/5 years ≤ (0.1 ⋅ r)%/year Gage pressure Absolute pressure (Absolute pressure, frontflushed) ≤ 0,075% ≤ 0,1% ≤ 0,2% ≤ 0.25%/5 years ≤ 0.1%/year Influence of ambient temperature • at -10 ... +60 °C (14 ... 140 °F) ≤ (0.1 ⋅ r +0.2)% ≤ (0.2 ⋅ r +0.3)% ≤ 0,3% • at -40 ... -10 °C and +60 ... +85 °C (-40 ... 14 °F and 140 ... 185 °F) ≤ (0.1 ⋅ r + 0.15)% / 10 K ≤ (0.2 ⋅ r + ≤ 0.25%/10 K 0.3)%/10 K ≤ 0,5% ≤ 0.5%/ 10 K Influence of the medium temperature (only with front-flush diaphragm) • Temperature difference between medium temperature and ambient temperature 3 mbar/10 K (0.04 psi/10 K) Siemens FI 01 · 2009 2/35 2 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for food, pharmaceuticals and biotechnology SITRANS P300 for gage and absolute pressure SITRANS P300 for gage pressure and absolute pressure HART PROFIBUS PA and FOUNDATION Fieldbus Rated operating conditions 2 Installation conditions Ambient temperature Observe the temperature class in areas subject to explosion hazard. • Measuring cell with silicone oil -40 ... +85 °C (-40 ... +185 °F) • Measuring cell with Neobee oil (with frontflush diaphragm) -10 ... +85 °C (14 ... +185 °F) • Measuring cell with inert liquid (not with front-flush diaphragm) -20 ... +85 °C (-4 ... +185 °F) • Digital display -30 ... +85 °C (-22 ... +185 °F) • Storage temperature -50 ... +85 °C (-58 ... +185 °F) (with Neobee: -20 ... +85 °C (-4 ... +185 °F) Climatic class Condensation Permissible Degree of protection to EN 60529 IP65, IP68, NEMA X, enclosure cleaning, resistant to lyes, steam to 150° C (302 °F) Electromagnetic compatibility • Emitted interference and interference immunity To EN 61326 and NAMUR NE 21 Medium conditions Process temperature • Measuring cell with silicone oil -40 ... +100 °C (-40 ... +212 °F) • Measuring cell with silicone oil (with frontflush diaphragm) -40 ... +150 °C (-40 ... +302 °F) • Measuring cell with Neobee oil (with frontflush diaphragm) -40 ... +150 °C (-40 ... +302 °F) • Measuring cell with silicone oil, with temper- -40 ... +200 °C (-40 ... +392 °F) ature isolator (only with front-flush diaphragm) • Measuring cell with inert liquid -20 ... +100 °C (-4 ... +212 °F) • Measuring cell with high temperature oil -10 ... +250 °C (14 ... +482 °F) Design (standard version) Weight (without options) Approx. 800 g (1.8 lb) Housing material Stainless steel, mat. No. 1.4301/304 Material of parts in contact with the medium • Connection shank Stainless steel, mat. No. 1.4404/316L or Hastelloy C276, mat. No. 2.4819 • Oval flange Stainless steel, mat. No. 1.4404/316L • Seal diaphragm Stainless steel, mat. No. 1.4404/316L or Hastelloy C276, mat. No. 2.4819 • Measuring cell filling • Silicone oil • Inert filling liquid Process connection • G½B to DIN EN 837-1 • Female thread ½-14 NPT • Oval flange PN 160 (MWP 2320 psi) with fastening thread: - 7/16-20 UNF to IEC 61518 - M10 as per DIN 19213 Design (version with front-flush diaphragm) Weight (without options) Approx. 1 ... 13 kg (2.2 ... 29 lb) Housing material Stainless steel, mat. No. 1.4301/304 Material of parts in contact with the medium • Process connection Stainless steel, mat. No. 1.4404/316L • Seal diaphragm Stainless steel, mat. No. 1.4404/316L • Measuring cell filling • Silicone oil • Inert filling liquid • FDA compliant fill fluid (Neobee oil) Process connection • Flanges as per EN and ASME • F&B and pharmaceutical flanges 2/36 Siemens FI 01 · 2009 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for food, pharmaceuticals and biotechnology SITRANS P300 for gage and absolute pressure SITRANS P300 for gage pressure and absolute pressure HART PROFIBUS PA and FOUNDATION Fieldbus Terminal voltage on transmitter 10.5 ... 42 V DC for intrinsically safe operation: 10.5 ... 30 V DC Supplied through bus Separate power supply - Not necessary Power supply UH 2 Bus voltage • Without EEx - 9 ... 32 V • For intrinsically-safe operation - 9 ... 24 V Current consumption • Max. basic current - 12.5 mA • Startup current ≤ basic current - Yes • Max. fault current in the event of a fault - 15.5 mA Fault disconnection electronics (FDE) - Available Certificate and approvals Classification according to pressure equipment directive (DRGL 97/23/EC) For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of Article 3, paragraph 3 (sound engineering practice) Water, waste water Available soon Explosion protection Intrinsic safety "i" PTB 05 ATEX 2048 Identification Ex II 1/2 G EEx ia/ib IIB/IIC T4, T5, T6 Permissible ambient temperature • Temperature class T4 -40 ... +85 °C (-40 ... +185 °F) • Temperature class T5 -40 ... +70 °C (-40 ... +158 °F) • Temperature class T6 -40 ... +60 °C (-40 ... +140 °F) Connection To certified intrinsically-safe circuits with maximum values: Ui = 30 V, Ii = 100 mA, Pi = 750 mW, Ri = 300 Ω To certified intrinsically-safe circuits with maximum values: FISCO supply unit: Ui = 17.5 V, Ii = 380 mA, Pi = 5.32 W Linear barrier: Ui = 24 V, Ii = 250 mA, Pi = 1.2 W Effective inner capacitance: Ci = 6 nF Ci = 1.1 nF Effective inner inductance: Li = 0.4 mH Li ≤ 7 μH Explosion protection to FM for USA and Canada (cFMUS) • Identification (DIP) or (IS); (NI) Certificate of Compliance 3025099 CL I, DIV 1, GP ABCD T4 ... T6; CL II, DIV 1, GP EFG; CL III; CL I, ZN 0/1 AEx ia IIC T4 ... T6; CL I, DIV 2, GP ABCD T4 ... T6; CL II, DIV 2, GP FG; CL III • Identification (DIP) or (IS) Certificate of Compliance 3025099C CL I, DIV 1, GP ABCD T4 ... T6; CL II, DIV 1, GP EFG; CL III; Ex ia IIC 4 ... T6; CL I, DIV 2, GP ABCD T4 ... T6; CL II, DIV 2, GP FG; CL III Siemens FI 01 · 2009 2/37 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for food, pharmaceuticals and biotechnology SITRANS P300 for gage and absolute pressure HART communication HART communication 2 Communication FOUNDATION Fieldbus 230 ... 1100 Ω Protocol HART Version 5.x Software for computer SIMATIC PDM Function blocks 3 function blocks analog input, 1 function block PID • Analog input PROFIBUS PA communication - Adaptation to customer-specif- Yes, linearly rising or falling charic process variables acteristic Simultaneous communication with 4 master class 2 (max.) - Electrical damping T63 , adjust- 0 ... 100 s able The address can be set using - Simulation function Output/input (can be locked within the device with a bridge) - Failure mode Can be parameterized (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively - Square-rooted characteristic for flow measurement Yes Configuration tool or local operation (standard setting address 126) Cyclic data usage • Output byte 5 (one measuring value) or 10 (two measuring values) • Input byte 0, 1, or 2 (register operating mode and reset function for metering) Internal preprocessing Device profile Function blocks PROFIBUS PA Profile for Process Control Devices Version 3.0, Class B • PID • Physical block 1 Resource block 2 Transducer blocks 1 transducer block Pressure with calibration, 1 transducer block LCD • Analog input - Adaptation to customer-specif- Yes, linearly rising or falling charic process variables acteristic - Electrical damping T63 , adjust- 0 ... 100 s able - Simulation function Input /Output - Failure mode Can be parameterized (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively • Register (totalizer) Can be reset, preset, optional direction of counting, simulation function of register output - Failure mode Can be parameterized (summation with last good value, continuous summation, summation with incorrect value) - Limit monitoring One upper and lower warning limit and one alarm limit respectively • Physical block 1 Transducer blocks 2 • Pressure transducer block - Can be calibrated by applying Yes two pressures - Monitoring of sensor limits Yes - Specification of a container characteristic with Max. 30 nodes - Square-rooted characteristic for flow measurement Yes - Gradual volume suppression and implementation point of square-root extraction Parameterizable - Simulation function for meaConstant value or over parametersured pressure value and sen- izable ramp function sor temperature 2/38 Siemens FI 01 · 2009 Standard FF function block • Pressure transducer block - Can be calibrated by applying Yes two pressures - Monitoring of sensor limits Yes - Simulation function: Measured Constant value or over parameterpressure value, sensor temper- izable ramp function ature and electronics temperature © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for food, pharmaceuticals and biotechnology SITRANS P300 for gage and absolute pressure Order No. Selection and Ordering data Order No. Selection and Ordering data SITRANS P300 pressure transmitters for gage and absolute pressure, single-chamber measuring housing, rating plate inscription in English SITRANS P300 pressure transmitters for gage and absolute pressure, single-chamber measuring housing, rating plate inscription in English 4 ... 20 mA/HART 7MF 8 0 2 3 - 4 ... 20 mA/HART 7MF 8 0 2 3 - PROFIBUS PA 7MF 8 0 2 4 - PROFIBUS PA 7MF 8 0 2 4 - FOUNDATION Fieldbus (FF) 7MF 8 0 2 5 - FOUNDATION Fieldbus (FF) 7MF 8 0 2 5 - 77777 - 7777 Measuring cell filling Silicone oil Inert liquid max. span 0.01 ... 1 bar g 0.04 ... 4 bar g 0.16 ...16 bar g 0.63 ... 63 bar g 1.6 ... 160 bar g 4 ... 400 bar g 2.5 ... 25 mbar a 13 ... 1300 mbar a 0.05 ... 5 bar a 0.3 ... 30 bar a Measuring cell cleaning Standard Cleanliness level 2 to DIN 25410 (0.145 ... 14.5 psi g) (0.58 ... 58 psi g) (2.32 ... 232 psi g) (9.14 ... 914 psi g) (23.2 ... 2320 psi g) (58 ... 5800 psi g) (0.036 ... 3.63 psi a) (0.19 ... 18.9 psi a) (0.7 ... 72.5 psi a) (4.35 ... 435 psi a) F) F) F) F) B C D E F G Q S T U Stainless steel Stainless steel Hastelloy 1 2 4 5 6 7 • With display (setting acc. to specifications, Order code "Y21" or "Y22" required), lid with glass pane Power supply units see "SITRANS I power supply units and isol. amplifiers". Wetted parts materials Seal diaphragm Measuring cell Stainless steel Hastelloy Hastelloy 77777 - 7777 Display • Without display, with keys, closed lid5) • With display and keys, closed lid • With display and keys, lid with macrolon washer (setting on HART devices: mA, on PROFIBUS PA and FOUNDATION Fieldbus devices: pressure units) • With display (setting acc. to specifications, Order code "Y21" or "Y22" required), lid with macrolon washer • With display and keys, lid with glass pane (setting on HART devices: mA, on PROFIBUS and FOUNDATION Fieldbus devices: pressure units) 1 3 2 Factory-mounting of shut-off valves and valve manifolds see page 2/142. F) F) Version for diaphragm seal 1) 2) Process connection • G½B to EN 837-1 • ½-14 NPT • Oval flange made of stainless steel - Mounting thread 7/16-20 UNF to EN 61518 - Mounting thread M10 to DIN 19213 - Mounting thread M12 to DIN 19213 • Male thread M20 x 1,5 • Male thread ½ -14 NPT Non-wetted parts materials • St. steel, deep-drawn and electrolytically polished Version • Standard version Explosion protection • Without • With ATEX, Type of protection: - "Intrinsic safety (EEx ia)" • Zone 20/21/223) • Ex nA/nL (zone 2)4) • With FM „Intrinsic safe“ (cFMUS) Electrical connection / cable entry • Screwed gland M20x1.5 (Polyamide) 5) • Screwed gland M20x1.5 (metal) • Screwed gland M20x1.5 (stainless steel) • M12 connector (metal, without cable socket) • M12 connector (stainless steel, without cable socket) • ½-14 NPT thread, metal 6) • ½-14 NPT thread, stainless steel6) A B C Included in delivery of the device: • Brief instructions (Leporello) • CD-ROM with detailed documentation Y 1) 0 1 2) 2 3 4 5 6 3) 4) 5) 6) When the manufacture’s certificate M (calibration certificate) has to be ordered for transmitters with diaphragm seals, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. Whe the acceptance test certificate 3.1 for transmitters with direct-connected diaphragm seals is ordered, this certificate must also be ordered with the corresponding seals. Can only be ordered in conjunction with electrical connection Option A. Can only be ordered in conjunction with electrical connection Option B, C, F or G. Only together with HART electronics. Without cable gland. F) Subject to export regulations AL: 9I999, ECCN: N. 4 1 A B C E M A B C F G H J Siemens FI 01 · 2009 2/39 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for food, pharmaceuticals and biotechnology SITRANS P300 for gage and absolute pressure Order No. Selection and Ordering data 2 Order No. Selection and Ordering data SITRANS P300 pressure transmitters for gage and absolute pressure with front-flush membrane, single-chamber measuring housing, rating plate inscription in English SITRANS P300 pressure transmitters for gage and absolute pressure with front-flush membrane, single-chamber measuring housing, rating plate inscription in English 4 ... 20 mA/HART F) 7 M F 8 1 2 3 - 4 ... 20 mA/HART F) 7 M F 8 1 2 3 - PROFIBUS PA F) 7 M F 8 1 2 4 - PROFIBUS PA F) 7 M F 8 1 2 4 - FOUNDATION Fieldbus (FF) F) 7 M F 8 1 2 5 - FOUNDATION Fieldbus (FF) F) 7 M F 8 1 2 5 - 77777 - 7777 Measuring cell filling Silicone oil Inert liquid Measuring cell cleaning Standard Cleanliness level 2 to DIN 25410 1 3 FDA compliant fill fluid • Neobee oil Standard 4 max. span 0.01 ... 1 bar g 0.04 ... 4 bar g 0.16 ... 16 bar g 0.63 ... 63 bar g (0.15 ... 14.5 psi g) (0.58 ... 58 psi g) (2.32 ... 232 psi g) (9.14 ... 914 psi g) B C D E 13 ... 1300 mbar a1) 0.05 ... 5 bar a1) 0.03 ... 30 bar a1) (0.19 ... 18.9 psi a) (0.7 ... 72.5 psi a) (4.35 ... 435 psi a) S T U Wetted parts materials Seal diaphragm Measuring cell Stainless steel Stainless steel Process connection • Flange version with Order code M.., N.., R.. or Q.. (see "Further designs") Non-wetted parts materials • Stainless steel, deep-drawn and electrolytically polished Version • Standard version Explosion protection • Without • With ATEX, Type of protection: - "Intrinsic safety (EEx ia)" • Zone 20/21/222) • Ex nA/nL (zone 2)3) • With FM „Intrinsic safe“ (cFMUS) Electrical connection / cable entry • Screwed gland M20x1.5 (Polyamide)4) • Screwed gland M20x1.5 (metal) • Screwed gland M20x1.5 (stainless steel) • M12 connector (without cable socket) • M12 connector (stainless steel, without cable socket) • ½-14 NPT thread, metal5) • ½-14 NPT thread, stainless steel5) 2/40 Siemens FI 01 · 2009 77777 - 7777 Display • Without display, with keys, closed lid4) • With display and keys, closed lid • With display and keys, lid with macrolon washer (setting on HART devices: mA, on PROFIBUS PA and FOUNDATION Fieldbus devices: pressure units) • With display (setting acc. to specifications, Order code "Y21" or "Y22" required), lid with macrolon washer • With display and keys, lid with glass pane (setting on HART devices: mA, on PROFIBUS PA and FOUNDATION Fieldbus devices: pressure units) • With display (setting acc. to specifications, Order code "Y21" or "Y22" required), lid with glass pane 1 2 4 5 6 7 Power supply units see "SITRANS I power supply units and isol. amplifiers". Included in delivery of the device: • Brief instructions (Leporello) • CD-ROM with detailed documentation A 1) 7 2) 4 3) 4) 5) 1 Not with temperature decoupler P00 and P10, not for process connections R02, R04, R10 and R11, and can only be ordered in conjunction with silicone oil. Can only be ordered in conjunction with electrical connection Option A. Can only be ordered in conjunction with electrical connection Option B, C, F or G. Only together with HART electronics. Without cable gland. F) Subject to export regulations AL: 9I999, ECCN: N. A B C E M A B C F G H J © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for food, pharmaceuticals and biotechnology SITRANS P300 for gage and absolute pressure Selection and Ordering data Order code A02 Mounting bracket made completely of stainless steel, for wall or pipe mounting Cable socket for M12 plug • Metal • Stainless steel Rating plate inscription (instead of English) • German • French • Spanish • Italian 9 9 9 9 A50 A51 FF Further designs Add "-Z" to Order No. and specify Order code. 9 Varivent connection certified to 3A and EHEDG3) • Type N = 68 for Varivent housing DN 40 ... 125 and 1½" ... 6", PN 40 9 9 B10 B12 B13 B14 9 9 9 9 9 9 9 9 9 9 9 9 B21 9 9 Quality inspection certificate (Factory cali- C11 bration) to IEC 60770-21) to IEC 60770-2 9 9 Acceptance test certificate2) to EN 10204-3.1 C12 9 Factory certificate to EN 10204-2.2 C14 Type of protection IP68 D12 English rating plate Pressure units in inH20 or psi Order code Selection and Ordering data HART PA Further designs Add "-Z" to Order No. and specify Order code. HART PA FF N28 9 9 9 P00 9 9 9 P10 Temperature decoupler up to 250 °C Measuring cell filling: High-temperature oil, only in conjunction with measuring cell filling silicone oil 9 9 9 Temperature decoupler up to 200 °C7) for version with front-flush diaphragm 9 Bio-Control (Neumo) sanitary connection certified to 3A and EHEDG3) • DN 50, PN 16 • DN 65, PN 16 Q53 Q54 9 9 9 9 9 9 9 Sanitary process connection to DRD • 65 mm, PN 40 M32 9 9 9 9 9 SMS socket with union nut • 2“ • 2½“ • 3“ M67 M68 M69 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 SMS threaded socket • 2“ • 2½“ • 3“ M73 M74 M75 9 9 9 9 9 9 9 9 9 IDF socket with union nut ISO 2853 • 2“ • 2½“ • 3“ M82 M83 M84 9 9 9 9 9 9 9 9 9 IDF threaded socket ISO 2853 • 2“ • 2½“ • 3“ M92 M93 M94 9 9 9 9 9 9 9 9 9 Sanitary process connection to NEUMO Bio-Connect screw connection certified to 3A and EHEDG3) • DN 50, PN 16 • DN 65, PN 16 • DN 80, PN 16 • DN 100, PN 16 • DN 2“, PN 16 • DN 2½“, PN 16 • DN 3“, PN 16 • DN 4“, PN 16 Q05 Q06 Q07 Q08 Q13 Q14 Q15 Q16 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 Sanitary process connection to NEUMO Bio-Connect flange connection certified to 3A and EHEDG3) • DN 50, PN 16 • DN 65, PN 16 • DN 80, PN 16 • DN 100, PN 16 • DN 2“, PN 16 • DN 2½“, PN 16 • DN 3“, PN 16 • DN 4“, PN 16 Q23 Q24 Q25 Q26 Q31 Q32 Q33 Q34 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 Sanitary process connection to NEUMO Bio-Connect clamp connection certified to 3A and EHEDG3) • DN 50, PN 16 • DN 65, PN 10 • DN 80, PN 10 • DN 100, PN 10 • DN 2½“, PN 16 • DN 3“, PN 10 • DN 4“, PN 10 Q39 Q40 Q41 Q42 Q48 Q49 Q50 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 Only for SITRANS P300 with front-flush diaphragm (7MF81..-...) Flange to EN 1092-1, form B1 • DN 25, PN 403) • DN 25, PN 1003) • DN 40, PN 40 • DN 40, PN 100 • DN 50, PN 16 • DN 50, PN 40 • DN 80, PN 25 • DN 80, PN 40 M11 M21 M13 M23 M04 M14 M06 M16 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 Flanges to ASME B16.5 • 1", class 1503) • 1½", class 150 • 2", class 150 • 3", class 150 • 4", class 150 • 1", class 3003) • 1½", class 300 • 2", class 300 • 3", class 300 M40 M41 M42 M43 M44 M45 M46 M47 M48 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 Threaded connection acc. to DIN 3852-2, Form A • G ¾“-A, flush-mounted4) • G 1“-A, flush-mounted4) • G 2“-A, flush-mounted4) R01 R02 R04 9 9 9 9 9 9 9 9 9 Tank connection5) Sealing is included in delivery • TG 52/50, PN 40 • TG 52/150, PN 40 R10 R11 9 9 9 9 9 9 Sanitary process connection according DIN 11851 (Dairy connection) certified to 3A6) • DN 50, PN 25 • DN 80, PN 25 N04 N06 9 9 9 9 9 9 Tri-Clamp connection according DIN 32676/ISO 2852 certified to 3A6) • DN 50/2“, PN 16 • DN 65/3“, PN 10 N14 N15 9 9 9 9 9 9 Siemens FI 01 · 2009 2/41 2 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for food, pharmaceuticals and biotechnology SITRANS P300 for gage and absolute pressure Selection and Ordering data Order code 2 Selection and Ordering data HART PA Further designs Add "-Z" to Order No. and specify Order code. FF Sanitary process connection to NEUMO Connect S flange connection certified to 3A and EHEDG • DN 50, PN 16 • DN 65, PN 10 • DN 80, PN 10 • DN 100, PN 10 • DN 2“, PN 16 • DN 2½“, PN 10 • DN 3“, PN 10 • DN 4“, PN 10 Q63 Q64 Q65 Q66 Q72 Q73 Q74 Q75 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 Aseptic threaded socket to DIN 11864-1 Form A • DN 50, PN 25 • DN 65, PN 25 • DN 80, PN 25 • DN 100, PN 25 N33 N34 N35 N36 9 9 9 9 9 9 9 9 9 9 9 9 Aseptic flange with notch to DIN 11864-2 Form A • DN 50, PN 16 • DN 65, PN 16 • DN 80, PN 16 • DN 100, PN 16 N43 N44 N45 N46 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 Aseptic flange with groove to DIN 11864-2 Form A • DN 50, PN 16 N43 + P11 • DN 65, PN 16 N44 + P11 • DN 80, PN 16 N45 + P11 • DN 100, PN 16 N46 + P11 Aseptic clamp with groove to DIN 11864-3 Form A • DN 50, PN 25 • DN 65, PN 25 • DN 80, PN 16 • DN 100, PN 16 1) 2) 3) 4) 5) 6) 7) Siemens FI 01 · 2009 HART PA N53 N54 N55 N56 9 9 9 9 9 9 9 9 9 9 9 9 FF Measuring range to be set Specify in plain text V (max. 5 digits): Y01: ... up to ... mbar, bar, kPa, MPa, psi Y01 9 Measuring point number (TAG No.) Max. 16 characters, specify in plain text: Y15: ........................................... Y15 9 9 9 Measuring point text Max. 27 characters, specify in plain text: Y16: ........................................... Y16 9 9 9 Entry of HART TAG Max. 8 characters, specify in plain text: Y17: ........................................... Y17 9 Setting of pressure indication in pressure Y21 units Specify in plain text (standard setting: mA): Y21: mbar, bar, kPa, MPa, psi, ... Note: The following pressure units can be selected: bar, mbar, mm H2O*), inH2O*), ftH2O*), mmHG, inHG, psi, Pa, kPa, MPa, g/cm2, kg/cm2, Torr, ATM or % *) ref. temperature 20 °C 9 9 9 Setting of pressure indicator in Y22 + non-pressure units Y01 Specify in plain text: Y22: ..... up to ..... l, m3, m, USg, ... (specification of measuring range in pressure units "Y01" is essential, unit with max. 5 characters) 9 9 9 Preset bus address possible between 1 ... 126) Specify in plain text: Y25: ..................... Y25 Only "Y01" and "Y21" can be factory preset When the manufacture’s certificate M (calibration certificate) has to be ordered for transmitters with diaphragm seals, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. Whe the acceptance test certificate 3.1 for transmitters with direct-connected diaphragm seals is ordered, this certificate must also be ordered with the corresponding seals. Special Viton seal included in delivery. Lower measuring limit -100 mbar g (1.45 psi g). The weldable socket can be ordered under accessories Certified to 3A. The maximum temperatures of the medium depend on the respective cell fillings. 3A certification only if used in conjunction with 3A-compliant sealing rings. 2/42 Order code Additional data Add "-Z" to Order No. and specify Order code. 9 = available Ordering example Item line: 7MF8023-1DB24-1AB7-Z B line: A02 + Y01 + Y21 C line: Y01: 1 ... 10 bar (14.5 ... 145 psi) C line: Y21: bar (psi) © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for food, pharmaceuticals and biotechnology SITRANS P300 for gage and absolute pressure ■ Dimensional drawings ෘ 2 DSSUR[ DSSUR[ + DSSUR[ + DSSUR[ DSSUR[ SITRANS P300, with oval flange, dimensions in mm (inch) ෘ DSSUR[ DSSUR[ DSSUR[ r DSSUR[ DSSUR[ DSSUR[ DSSUR[ DSSUR[ SITRANS P300, process connection M20 x 1,5, with mounted mounting bracket, dimensions in mm (inch) Siemens FI 01 · 2009 2/43 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for food, pharmaceuticals and biotechnology SITRANS P300 for gage and absolute pressure ෘ + DSSUR[ 2 SITRANS P300, front-flush, dimensions in mm (inch) The diagram shows a SITRANS P300 with an example of a flange. In this drawing the height is subdivided into H1 and H2. H1 = Height of the SITRANS P300 up to a defined cross-section H2 = Height of the flange up to this defined cross-section Only the height H2 is indicated in the dimensions of the flanges. 2/44 Siemens FI 01 · 2009 + DSSUR[ 7HPSHUDWXUHGHFRXSOHU r © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for food, pharmaceuticals and biotechnology SITRANS P300 for gage and absolute pressure Flanges to EN and ASME Sanitary process connection to DRD Flanges to EN ' + DN PN ∅D H2 25 25 40 40 50 50 80 80 40 100 40 100 16 40 16 40 115 mm (4.5“) 140 mm (5.5“) 150 mm (5.9“) 170 mm (6.7“) 165 mm (6.5“) 165 mm (6.5“) 200 mm (7.9“) 200 mm (7.9“) Approx. 52 mm (2“) ' DN class ∅D 1“ 1“ 1½“ 1½“ 2“ 2“ 3“ 3“ 4“ 4“ 150 300 150 300 150 300 150 300 150 300 110 mm (4.3“) Approx. 125 mm (4.9“) 52 mm (2“) 130 mm (5.1“) 155 mm (6.1“) 150 mm (5.9“) 165 mm (6.5“) 190 mm (7.5“) 210 mm (8.1“) 230 mm (9.1“) 255 mm (10.0“) H2 NuG and pharmaceutical connections Connections to DIN ' DIN 11851 (Dairy connection) + ∅D H2 50 40 105 mm (4.1“) Approx. 52 mm (2“) 2 DN PN ∅D H2 50 16 82 mm (3.2“) 65 16 105 mm (4.1“) Approx. 52 mm (2“) 80 16 115 mm (4.5“) 100 16 145 mm (5.7“) 2“ 16 82 mm (3.2“) 2½“ 16 105 mm (4.1“) 3“ 16 105 mm (4.1“) 4“ 16 145 mm (5.7“) Sanitary connection to NEUMO Bio-Connect flange connection + + ASME B16.5 DN PN ∅D H2 50 16 110 mm (4.3“) 65 16 140 mm (5.5“) Approx. 52 mm (2“) 80 16 150 mm (5.9“) 100 16 175 mm (6.9“) 16 100 mm (3.9“) PN ∅D 2“ DN H2 2½“ 16 110 mm (4.3“) 50 25 92 mm (3.6“) 16 140 mm (5.5“) 25 127 mm (5.0“) Approx. 52 mm (2“) 3“ 80 4“ 16 175 mm (6.9“) ' Sanitary connection to NEUMO Bio-Connect clamp connection Tri-Clamp according DIN 32676 PN PN ∅D DN DN H2 ∅D 50 16 50 16 64 mm (2.5“) 65 10 77,4 mm (3.0“) Approx. 52 mm (2“) 90,9 mm (3.6“) 65 16 91 mm (3.6“) Approx. 52 mm (2“) 80 10 106 mm (4.2“) 100 10 119 mm (4.7“) 2“ 16 64 mm (2.5“) 2½“ 16 77,4 mm (3.0“) 3“ 10 90,9 mm (3.6“) 4“ 10 119 mm (4.7“) + + PN Sanitary process screw connection to NEUMO Bio-Connect Flanges to ASME ' DN ' + + EN 1092-1 ' ' Other connections Varivent connection PN ∅D H2 40 ... 125 40 84 mm (3.3“) Approx. 52 mm (2“) + DN H2 Sanitary connection to NEUMO Bio-Connect S flange connection + ' + Bio-Control connection ' DN PN ∅D H2 50 16 90 mm (3.5“) 65 16 120 mm (4.7“) Approx. 52 mm (2“) ' DN PN ∅D H2 50 16 125 mm (4.9“) 65 10 145 mm (5.7“) Approx. 52 mm (2“) 80 10 155 mm (6.1“) 100 10 180 mm (7.1“) 2“ 16 125 mm (4.9“) 2½“ 10 135 mm (5.3“) 3“ 10 145 mm (5.7“) 4“ 10 180 mm (7.1“) Siemens FI 01 · 2009 2/45 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for food, pharmaceuticals and biotechnology SITRANS P300 for gage and absolute pressure Thread connection G¾“, G1“ and G2“ to DIN 3852 H2 DN ¾“ 63 37 mm (1.5“) Approx. 45 mm (1.8“) 50 65 80 25 110 x ¼“ 100 25 130 x ¼“ 2“ 63 48 mm (1.9“) 63 78 mm (3.1“) Approx. 47 mm (1.9“) + ∅D + PN 1“ ' Approx. 52 mm (2“) ∅D H2 25 78 x 1/6“ 25 95 x 1/6“ Approx. 52 mm (2.1“) PN ' DN PN ∅D H2 25 40 63 mm (2.5“) Approx. 63 mm (2.5“) 25 40 63 mm (2.5“) Approx.170 mm (6.7“) Aseptic flange with notch to DIN 11864-2 Form A DN + + Tank connection TG52/50 und TG52/150 ' ' DN PN ∅D H2 2“ 25 84 mm (3.3“) 2½“ 25 100 mm (3.9“) Approx. 52 mm (2.1“) 3“ 25 114 mm (4.5“) ' ' PN ∅D H2 H2 Approx. 52 mm (2.1“) 50 16 94 65 16 113 80 16 133 100 16 159 DN PN ∅D H2 50 16 94 65 16 113 Approx. 52 mm (2.1“) 80 16 133 100 16 159 2“ 25 70 x 1/6 mm Approx. 52 mm (2.1“) 2½“ 25 85 x 1/6 mm 3“ 25 98 x 1/6 mm DN + + DN ' ' IDF socket with union nut + ∅D Aseptic clamp with groove to DIN 11864-3 Form A SMS threaded socket DN PN ∅D H2 2“ 25 77 mm (3“) 2½“ 25 91 mm (3.6“) Approx. 52 mm (2.1“) 3“ 25 106 mm (4.2“) DN PN ∅D H2 2“ 25 64 mm (2.5“) 2½“ 25 77,5 mm (3.1“) Approx. 52 mm (2.1“) 3“ 25 91 mm (3.6“) ' IDF threaded socket ' 2/46 PN Aseptic flange with groove to DIN 11864-2 Form A + + SMS socket with union nut + 2 Aseptic threaded socket to DIN 11864-1 Form A DN Siemens FI 01 · 2009 PN ∅D H2 Approx. 52 mm (2.1“) 50 25 77,5 65 25 91 80 16 106 100 16 130 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage pressure for the paper industry SITRANS P300 and DS III series with PMC connection – Technical description ■ Overview • Small long-term drift • Wetted parts made of Hastelloy • Infinitely adjustable spans from 30 mbar g to 16 bar g for DS III with HART interface • Nominal measuring range from 1 mbar g to 16 bar g for DS III with PROFIBUS PA and FOUNDATION Fieldbus interface • Infinitely adjustable spans from 30 mbar g to 16 bar g for SITRANS P300 with HART interface • Nominal measuring range from 1 bar g to 16 bar g for SITRANS P300 with PROFIBUS PA interface • High measuring accuracy • Parameterization over control keys and HART communication, or over PROFIBUS PA or FOUNDATION Fieldbus interface (DS III only). ■ Application The pressure transmitters of the DS III series, can be used in industrial areas with extreme chemical and mechanical loads. Electromagnetic compatibility in the range 10 kHz ... 1 GHz makes the DS III pressure transmitters suitable for locations with high electromagnetic emissions. Pressure transmitters with type of protection "Intrinsic safety" and "Explosion-proof" may be installed within potentially explosive atmospheres (zone 1) or in zone 0. The pressure transmitters are provided with an EC type examination certificate and comply with the corresponding harmonized European standards (ATEX). Pressure transmitters with the type of protection "Intrinsic safety" for use in zone 0 may be operated with power supply units of category "ia" and "ib". The SITRANS P300 and DS III pressure transmitters have been fitted with special process connections for the paper industry. With the two process connection threads 1½" and 1" flush at the front, the SITRANS P300 and DS III transmitters can be used for all processes in the paper industry. The transmitters can be equipped with various designs of remote seals for special applications such as the measurement of highly viscous substances. The pressure transmitter can be operated locally over 3 control keys or programmed externally over HART communication or over PROFIBUS PA or FOUNDATION Fieldbus interface (only DS III). SITRANS P300 and DS III series pressure transmitters are digital pressure transmitters featuring extensive user-friendliness and high accuracy. The parameterization is performed using control keys, over HART communication, PROFIBUS PA or FOUNDATION Fieldbus interface (DS III only). SITRANS P, DS III series Extensive functionality enables the pressure transmitter to be precisely adapted to the plant’s requirements. Operation is very simple in spite of the numerous setting options. For DS III HART: 0.03 ... 16 bar g (0.433 ... 232 psi g) Transmitters with type of protection "Intrinsic safety" and "Explosion-proof" may be installed within potentially explosive atmospheres (zone 1) or in zone 0. The transmitters are provided with an EC type examination certificate and comply with the corresponding harmonized European standards (ATEX). For DS III PA and FF: 1 ... 16 bar g (14.5 ... 232 psi g) Various versions of the pressure transmitters are available for measuring: • Gage pressure • Filling level • Volume level • Mass level Nominal measuring range Measured variable: Gage pressure of aggressive and nonaggressive gases, vapors and liquids. Span (infinitely adjustable) Nominal measuring range SITRANS P300 Span (infinitely adjustable) For DS III HART: 0.03 ... 16 bar g (0.433 ... 232 psi g) For DS III PA: 1 ... 16 bar g (14.5 ... 232 psi g) ■ Benefits • High quality and long life • High reliability even under extreme chemical and mechanical loads, e.g. abrasion. • For aggressive and non-aggressive gases, vapors and liquids • Extensive diagnosis and simulation functions • Minimum conformity error Siemens FI 01 · 2009 2/47 2 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage pressure for the paper industry SITRANS P300 and DS III series with PMC connection – Technical description ■ Design SITRANS P300 SITRANS P, DS III series 2 The device comprises: • Electronics • Housing • Measuring cell Device front view, SITRANS P DS III The transmitter comprises a range of different components, depending on the order specifications. The various options are listed in the ordering information. The components described below are the same for all transmitters. The rating plate (3, Figure "Front view") with the Order No. is located on the side of the housing. The specified number together with the ordering information provide details on the optional design details and on the possible measuring range (physical properties of built-in sensor element). The approval label is located on the opposite side. The housing is made of die-cast aluminium or stainless steel precision casting. A round cover is screwed on at the front and rear of the housing. The front cover (6) can be fitted with a viewing pane so that the measured values can be read directly on the digital display. The inlet (4) for the electrical connection is located either on the left or right side. The unused opening on the opposite side is sealed by a blanking plug. The protective earth connection is located on the rear of the housing. The electrical connections for the power supply and screen are accessible by unscrewing the rear cover. The bottom part of the housing contains the measuring cell with process connection (1). The measuring cell is prevented from rotating by a locking screw (8). As the result of this modular design, the measuring cell and the electronics can be replaced separately from each other. The set parameter data are retained. At the top of the housing is a plastic cover (5), which hides the input keys. 2/48 Siemens FI 01 · 2009 Perspective view of the SITRANS P300 The housing has a screwable cover (3), with or without an inspection window depending on the version. The electrical terminal housing, the buttons for operation of the device and, depending on the version, the digital display are located under this cover. The connections for the auxiliary power UH and the shield are in the terminal housing. The cable gland is on the side of the housing. The measuring cell with the process connection (5) is located on the underside of the housing. Depending on the version of the device, the measuring cell with the process connection may differ from the one shown in the diagram. © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage pressure for the paper industry SITRANS P300 and DS III series with PMC connection – Technical description ■ Function Operation of the electronics with PROFIBUS PA communication Operation of the electronics with PROFIBUS PA communication 9 8 M 2 3 4 mC 5 mC 10 5 4 3 2 2 7 PA interface IA, UH EEPROM 7 6 HART interface Electronics 6 1 Electronics 1 Pe 1 2 3 4 5 6 7 8 9 10 IA UH Pe Sensor EEPROM 6 Sensor Measuring cell Measuring cell sensor Instrument amplifier Analog-to-digital converter Microcontroller Digital-to-analog converter One non-volatile memory each in the measuring cell and electronics HART interface Three input keys (local operation) Digital display Diode circuit and connection for external ammeter Output current Power supply Input variable Function diagram of electronics The bridge output voltage created by the sensor (1, Figure "Function diagram of electronics") is amplified by the instrument amplifier (2) and digitized in the analog-to-digital converter (3). The digital information is evaluated in a microcontroller, its linearity and temperature response corrected, and converted in a digital-to-analog converter (5) into an output current of 4 to 20 mA. The diode circuit (10) protects against incorrect polarity. The data specific to the measuring cell, the electronics data, and the parameter data are stored in the two non-volatile memories (6). The one memory is coupled to the measuring cell, the other to the electronics. As the result of this modular design, the electronics and the measuring cell can be replaced separately from each other. Using the 3 input keys (8) you can parameterize the pressure transmitter directly at the point of measurement. The input keys can also be used to control the view of the results, the error messages and the operating modes on the digital display (9). 6 pe 1 2 3 4 5 6 7 Power supply unit Coupler 11 12 BusMaster EEPROM EEPROM Power supply 10 PROFIBUS-DP 0 0 00 0 00 PROFIBUS-PA 8 0 0 00 0 00 M 9 Measuring cell Measuring cell sensor Instrument amplifier Analog-to-digital converter Microcontroller Electrical isolation One non-volatile memory each in the measuring cell and electronics PROFIBUS-PA interface 8 9 10 11 12 Three input keys (local operation) Digital display Power supply DP/PA coupler or link Bus master pe Input variable Function diagram of electronics The bridge output voltage created by the sensor (1, Figure "Function diagram of electronics") is amplified by the instrument amplifier (2) and digitized in the analog-to-digital converter (3). The digital information is evaluated in the microcontroller, its linearity and temperature response corrected, and provided on the PROFIBUS PA through an electrically isolated PA interface (7). The data specific to the measuring cell, the electronics data, and the parameter data are stored in the two non-volatile memories (6). The first memory is linked with the measuring cell, the second with the electronics. This modular design means that the electronics and the measuring cell can be replaced separately from one another. Using the three input keys (8) you can parameterize the pressure transmitter directly at the point of measurement. The input keys can also be used to control the view of the results, the error messages and the operating modes on the digital display (9). The results with status values and diagnostic values are transferred by cyclic data transmission on the PROFIBUS PA. Parameterization data and error messages are transferred by acyclic data transmission. Special software such as SIMATIC PDM is required for this. The HART modem (7) permits parameterization using a protocol according to the HART specification. The pressure transmitters with spans ≤ 63 bar g measure the input pressure compared to atmosphere, transmitters with spans ≥ 160 bar g compared to vacuum. Siemens FI 01 · 2009 2/49 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage pressure for the paper industry SITRANS P300 and DS III series with PMC connection – Technical description Mode of operation of the FOUNDATION Fieldbus electronics 0 0 00 0 00 M 2 2 Measuring cell for gage pressure with front-flush diaphragm 9 8 Mode of operation of the measuring cell 3 4 5 mC EEPROM 7 FF interface Power supply 10 5 4 1 Power supply unit 6 Coupler Electronics 1 pe 1 2 3 4 5 6 7 EEPROM 3 p e Measuring cell for gage pressure, with front-flush diaphragm, function diagram Measuring cell Measuring cell sensor Instrument amplifier Analog-to-digital converter Microcontroller Electrical isolation One non-volatile memory each in the measuring cell and electronics FF interface Measuring cell Process connection Seal diaphragm Filling liquid Silicon pressure sensor Pressure as input variable 2 6 Sensor 1 2 3 4 5 pe 8 9 10 Three input keys (local operation) Digital display Power supply pe Input variable Function diagram of electronics The bridge output voltage created by the sensor (1, Figure "Function diagram of electronics") is amplified by the instrument amplifier (2) and digitized in the analog-to-digital converter (3). The digital information is evaluated in the microcontroller, its linearity and temperature response corrected, and provided on the FOUNDATION Fieldbus through an electrically isolated FOUNDATION Fieldbus Interface (7). The data specific to the measuring cell, the electronics data, and the parameter data are stored in the two non-volatile memories (6). The one memory is coupled to the measuring cell, the other to the electronics. As the result of this modular design, the electronics and the measuring cell can be replaced separately from each other. Using the three input keys (8) you can parameterize the pressure transmitter directly at the point of measurement. The input keys can also be used to control the view of the results, the error messages and the operating modes on the digital display (9). The results with status values and diagnostic values are transferred by cyclic data transmission on the FOUNDATION Fieldbus. Parameterization data and error messages are transferred by acyclic data transmission. Special software such as National Instruments Configurator is required for this. The pressure pe is applied through the process connection (2, Figure "Measuring cell for gage pressure, with front-flush diaphragm for paper industry, function diagram") to the measuring cell (1). This pressure is subsequently transmitted further through the seal diaphragm (3) and the filling liquid (4) to the silicon pressure sensor (5) whose measuring diaphragm is then flexed. This changes the resistance of the four piezo-resistors fitted in the diaphragm in a bridge circuit. This change in resistance results in a bridge output voltage proportional to the input pressure. Parameterization Depending on the version, there are a range of options for parameterizing the pressure transmitter and for setting or scanning the parameters. Parameterization using the input keys (local operation) With the input keys you can easily set the most important parameters without any additional equipment. Parameterization using HART communication Parameterization using HART communication is performed with a HART communicator or a PC. + 230 ... 1100 W SITRANS P transmitter Power supply HART communicator Communication between a HART communicator and a pressure transmitter When parameterizing with the HART communicator, the connection is made directly to the 2-wire system. 2/50 Siemens FI 01 · 2009 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage pressure for the paper industry SITRANS P300 and DS III series with PMC connection – Technical description Parameterization through PROFIBUS PA interface 230 ... 500 W SITRANS P transmitter Power supply PC or laptop HART modem Fully digital communication through PROFIBUS PA, profile 3.0, is particularly user-friendly. The PROFIBUS puts the DS III PA is in connection with a process control system, e.g. SIMATIC PSC 7. Communication is possible even in a potentially explosive environment. For parameterization through PROFIBUS you need suitable software, e.g. SIMATIC PDM (Process Device Manager). RS 232 Parameterization through FOUNDATION Fieldbus Interface HART communication between a PC communicator and a pressure transmitter When parameterizing with a PC, the connection is made through a HART modem. The signals needed for communication in conformity with the HART 5.x or 6.x protocols are superimposed on the output current using the Frequency Shift Keying (FSK) method. Fully digital communication through FOUNDATION Fieldbus is particularly user-friendly. Through the FOUNDATION Fieldbus the DS III FF is connected to a process control system. Communication is possible even in a potentially explosive environment. For parameterization through the FOUNDATION Fieldbus you need suitable software, e.g. National Instruments Configurator. Adjustable parameters for DS III PA and FF and P300 PA and FF Adjustable parameters Input keys PROFIBUS PA and FOUNDATION Fieldbus interface HART communication Electrical damping x x x x Adjustable parameter DS III HART and P300 HART Parameters Input keys Start of scale x x Zero adjustment (correction of position) Full-scale value x x Key and/or function disabling x x Electrical damping x x x x Start-of-scale value without application of a pressure ("Blind setting") x x Source of measured-value display Physical dimension of display x x Full-scale value without application of a x pressure ("Blind setting") x Position of decimal point x x Bus address x x Adjustment of characteristic x Zero adjustment x Current transmitter x x x Fault current x x Disabling of keys, write protection x x1) Type of dimension and actual dimension x x Characteristic (linear) x x Input of characteristic x Freely-programmable LCD x Diagnostics functions x 1) Cancel apart from write protection Diagnostic functions for DS III HART and P300 HART • Zero correction display • Event counter • Limit transmitter • Saturation alarm • Slave pointer • Simulation functions • Maintenance timer Available physical units of display for DS III HART and P300 HART x Input of characteristic x Freely-programmable LCD x Diagnostic functions x Diagnostic functions for DS III PA and FF and P300 PA and FF • Event counter • Slave pointer • Maintenance timer • Simulation functions • Display of zero correction • Limit transmitter • Saturation alarm Physical dimensions available for the display Physical variable Physical dimensions Pressure (setting can also be made in the factory) MPa, kPa, Pa, bar, mbar, torr, atm, psi, g/cm2, kg/cm2, mmH2O, mmH2O (4 °C), inH2O, inH20 (4 °C), ftH2O (20 °C), mmHg, inHg Level (height data) m, cm, mm, ft, in, yd Physical variable Physical dimensions Mass g, kg, t, lb, Ston, Lton, oz Pressure (setting can also be made in the factory) Pa, MPa, kPa, bar, mbar, torr, atm, psi, g/cm2, kg/cm2, inH2O, inH2O (4 °C), mmH2O, ftH2O (20 °C), inHg, mmHg Volume m3, dm3, hl, yd3, ft3, in3, US gallon, lmp, gallon, bushel, barrel, barrel liquid Level (height data) m, cm, mm, ft, in Volume m3, dm3, hl, yd3, ft3, in3, US gallon, Temperature K, °C, °F, °R Miscellaneous % lmp, gallon, bushel, barrel, barrel liquid Mass g, kg, t, lb, Ston, Lton, oz Temperature K, °C, °F, °R Miscellaneous %, mA Siemens FI 01 · 2009 2/51 2 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage pressure for the paper industry DS III series with PMC connection ■ Technical specifications SITRANS P, DS III series for gage pressure with PMC connection for the paper industry HART 2 PROFIBUS PA or FOUNDATION Fieldbus Input Measured variable Gage pressure Spans (infinitely adjustable) or nominal measuring range and max. permissible test pressure Span Max. perm. test pressure Nominal measuring range Max. perm. test pressure 0.01 ... 1 bar g (0.145 ... 14.5 psi g) 6 bar g (87 psi g) 1 bar g (14.5 psi g) 6 bar g (87 psi g) 0.04 ... 4 bar g (0.58 ... 58 psi g) 10 bar g (145 psi g) 4 bar g (58 psi g) 10 bar g (145 psi g) 0.16 ... 16 bar g (2.32 ... 232 psi g) 32 bar g (464 psi g) 16 bar g (232 psi g) 32 bar g (464 psi g) Lower measuring limit • Measuring cell with silicone oil filling 100 mbar a (1.45 psi a) Upper measuring limit 100% of max. span Output Output signal 4 ... 20 mA Digital PROFIBUS PA or FOUNDATION Fieldbus signal • Lower limit (infinitely adjustable) 3.55 mA, factory preset to 3.84 mA - • Upper limit (infinitely adjustable) 23 mA, factory preset to 20.5 mA or optionally set to 22.0 mA Load • Without HART communication RB ≤ (UH - 10.5 V)/0.023 A in Ω, UH : Power supply in V - • With HART communication RB = 230 ... 500 Ω (SIMATIC PDM) or RB = 230 ... 1100 Ω (HART Communicator) - Physical bus - IEC 61158-2 With polarity reversal protection - Yes Accuracy To EN 60770-1 Reference conditions (All error data refer always refer to the set span) Increasing characteristic, start-of-scale value 0 bar, stainless steel seal diaphragm, silicone oil filling, room temperature 25 °C (77 °F) r: Span ratio (r = max. span/set span) Error in measurement and fixed-point setting (including hysteresis and repeatability) ≤ 0,075% • Linear characteristic - r ≤ 10 ≤ (0.0029 ⋅ r + 0.071)% - 10 < r ≤ 30 ≤ (0.0045 ⋅ r + 0.071)% - 30 < r ≤ 100 ≤ (0.005 ⋅ r + 0.05)% Long-term drift (temperature change ± 30 °C ≤ (0.25 ⋅ r)% every 5 years (± 54 °F)) ≤ 0.25% every 5 years Influence of ambient temperature • at -10 ... +60 °C (14 ... 140 °F) ≤ (0.08 ⋅ r + 0.1)% ≤ 0,3% • at -40 ... -10 °C and +60 ... +85 °C (-40 ... +14 °F and 140 ... 185 °F) ≤ (0.1 ⋅ r + 0.15)%/10 K ≤ 0.25%/10 K Influence of medium temperature • Temperature difference between medium temperature and ambient temperature 3 mbar/10 K (0.04 psi/10 K) Influence of mounting position ≤ 0.1 mbar g (0.00145 psi g) per 10° inclination Measured Value Resolution - 2/52 Siemens FI 01 · 2009 3 ⋅ 10-5 of nominal measuring range © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage pressure for the paper industry DS III series with PMC connection SITRANS P, DS III series for gage pressure with PMC connection for the paper industry HART PROFIBUS PA or FOUNDATION Fieldbus Rated operating conditions Degree of protection (to EN 60529) IP65, IP68, NEMA X, enclosure cleaning, resistant to lyes, steam to 150° C (302 °F) Process temperature -20 ... +100 °C (-4 ... +212 °F) 2 Ambient conditions • Ambient temperature -20 ... +85 °C (-4 ... +185 °F) • Storage temperature -50 ... +85 °C (-58 ... +185 °F) • Climatic class - Condensation Permissible • Electromagnetic compatibility - Emitted interference and interference immunity To EN 61326 and NAMUR NE 21 Design Weight (without options) ≈ 1.5 kg (≈ 3.3 lb) Housing material Poor in copper die-cast aluminium, GD-AlSi12 or stainless steel precision casting, mat. No. 1.4408 Wetted parts materials Stainless steel • Gasket (standard) PTFE flat gasket • O-ring (minibolt) FPM (Viton) or optionally: FFPM or NBR Measuring cell filling Silicone oil or inert filling liquid Process connection (standard) Front-flush, 1½", PMC Standard design Process connection (minibolt) Front-flush, 1", minibolt design Supplied through bus Power supply UH Terminal voltage on transmitter 10.5 ... 45 V DC 10.5 ... 30 V DC in intrinsically-safe mode - Separate 24 V power supply necessary - No Bus voltage • Not Ex - 9 ... 32 V • With intrinsically-safe operation - 9 ... 24 V • Basic current (max.) - 12.5 mA Yes Current consumption • Startup current ≤ basic current - • Max. current in event of fault - 15.5 mA Fault disconnection electronics (FDE) available - Yes Certificate and approvals Classification according to pressure equipment directive (DRGL 97/23/EC) For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of Article 3, paragraph 3 (sound engineering practice) Siemens FI 01 · 2009 2/53 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage pressure for the paper industry DS III series with PMC connection SITRANS P, DS III series for gage pressure with PMC connection for the paper industry Communication FOUNDATION Fieldbus Function blocks HART communication 2 HART communication 230 ... 1100 Ω Protocol HART Version 5.x Software for computer SIMATIC PDM 3 function blocks analog input, 1 function block PID • Analog input - Adaptation to customer-specif- Yes, linearly rising or falling charic process variables acteristic PROFIBUS PA communication - Electrical damping T63 , adjust- 0 ... 100 s able Simultaneous communication with 4 master class 2 (max.) - Simulation function Output/input (can be locked within the device with a bridge) The address can be set using - Failure mode Can be parameterized (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively - Square-rooted characteristic for flow measurement Yes Configuration tool or local operation (standard setting address 126) Cyclic data usage • Output byte 5 (one measuring value) or 10 (two measuring values) • Input byte 0, 1, or 2 (register operating mode and reset function for metering) Internal preprocessing Device profile Function blocks PROFIBUS PA Profile for Process Control Devices Version 3.0, Class B - Electrical damping T63 , adjust- 0 ... 100 s able - Simulation function Input /Output - Failure mode Can be parameterized (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively Can be reset, preset, optional direction of counting, simulation function of register output - Failure mode Can be parameterized (summation with last good value, continuous summation, summation with incorrect value) - Limit monitoring One upper and lower warning limit and one alarm limit respectively • Physical block 1 Transducer blocks 2 • Pressure transducer block - Can be calibrated by applying Yes two pressures - Monitoring of sensor limits Yes - Specification of a container characteristic with Max. 30 nodes - Square-rooted characteristic for flow measurement Yes - Gradual volume suppression and implementation point of square-root extraction Parameterizable - Simulation function for meaConstant value or over parametersured pressure value and sen- izable ramp function sor temperature Siemens FI 01 · 2009 1 Resource block Transducer blocks 1 transducer block Pressure with calibration, 1 transducer block LCD • Pressure transducer block - Adaptation to customer-specif- Yes, linearly rising or falling charic process variables acteristic 2/54 Standard FF function block • Physical block 2 • Analog input • Register (totalizer) • PID - Can be calibrated by applying Yes two pressures - Monitoring of sensor limits Yes - Simulation function: Measured Constant value or over parameterpressure value, sensor temper- izable ramp function ature and electronics temperature © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage pressure for the paper industry DS III series with PMC connection Selection and Ordering data Order No. Selection and Ordering data SITRANS P pressure transmitters for gage pressure, with PMC connection series DS III HART 7MF 4 1 3 3 - SITRANS P pressure transmitter for gage pressure, with PMC connection Measuring cell filling Silicone oil Inert liquid Measuring cell cleaning Standard Grease-free Span 0.01 ... 1 bar g1) 0.04 ... 4 bar g 0.16 ... 16 bar g (0.15 ... 14.5 psi g)1) (0.58 ... 58 psi g) (2.32 ... 232 psi g) 77777 - 7777 Stainless steel Process connection • PMC Style Standard: Thread 1½" • PMC Style Mini bolt: 1" front-flush (min. span: 500 mbar (7.25 psi), can not be ordered with mit 1-bar (14.5 psi) measuring cell (Option B)) Non-wetted parts materials • Housing made of die-cast aluminum • Housing stainless steel precision casting Version • Standard version • International version, English label inscriptions, documentation in 5 languages on CD Explosion protection • None Electrical connection / cable entry • Female thread M20x1.5 • Female thread ½-14 NPT • M12 connectors (metal) Only with "PMC Style Standard" process connection 7MF 4 1 3 5 - Silicone oil Inert liquid B C D Measuring cell cleaning Standard Grease-free Nominal measuring range 1 bar g1) (14.5 psi g)1) 4 bar g (58 psi g) 16 bar g (232 psi g) B 1 3 B C D Wetted parts materials Seal diaphragm Connection shank 2 3 Hastelloy Stainless steel Process connection • PMC Style Standard: front-flush 1½" • PMC Style Mini bolt: front-flush 1" (min. span: 500 mbar (7.25 psi), can not be ordered with mit 1-bar (14.5 psi) measuring cell (Option B)) 0 3 B 2 3 Non-wetted parts materials • Housing made of die-cast aluminum • Housing stainless steel precision casting 1 2 Version • Standard version • International version, English label inscriptions, documentation in 5 languages on CD A B C F Power supply units see "SITRANS I power supply units and isolation amplifiers". 1) 7MF 4 1 3 4 - DS III FF series (FOUNDATION Fieldbus) Measuring cell filling Display • Without indicator • Without visible digital indicator (digital indicator } hidden, setting: mA) • With visible digital indication, setting: mA • With customer-specific digital indication (setting as specified, Order code "Y21" or "Y22" required) Included in delivery of the device: • Brief instructions (Leporello) • CD-ROM with detailed documentation • Sealing ring DS III PA (PROFIBUS PA) series 77777 - 7777 1 3 Wetted parts materials Seal diaphragm Connection shank Hastelloy Order No. Explosion protection • None 0 1 6 7 0 3 1 2 A Electrical connection / cable inlet • Screwed gland M20x1.5 • Screwed gland ½-14 NPT • M12 connectors (metal) B C F Display • Without indicator • Without visible digital indicator (digital indicator } hidden, setting: mA) • With visible digital display • With customer-specific digital display (setting as specified, Order code "Y21" or required) 0 1 6 7 Included in delivery of the device: • Brief instructions (Leporello) • CD-ROM with detailed documentation • Sealing ring 1) Only with "PMC Style Standard" process connection Siemens FI 01 · 2009 2/55 2 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage pressure for the paper industry DS III series with PMC connection Selection and Ordering data Order code Selection and Ordering data HART PA Further designs FF Add "-Z" to Order No. and specify Order code. 2 Order code HART PA Additional data FF Add "-Z" to Order No. and specify Order code. A50 9 9 9 Measuring range to be set Specify in plain text (max. 5 digits): Y01: ... up to ... mbar, bar, kPa, MPa, psi Y01 9 • English • French • Spanish • Italian B11 B12 B13 B14 9 9 9 9 9 9 9 9 9 9 9 9 Measuring point number (TAG No.) Max. 16 characters, specify in plain text: Y15: ........................................... Y15 9 9 9 Y16 9 9 9 English rating plate Pressure units in inH20 or psi B21 9 9 9 Measuring point text Max. 27 characters, specify in plain text: Y16: ........................................... 9 9 9 9 Entry of HART address (TAG) Max. 8 characters, specify in plain text: Y17: ........................................... Y17 Quality inspection certificate (Factory cali- C11 bration) to IEC 60770-2 Acceptance test certificate To EN 10204-3.1 C12 9 9 9 9 9 9 Factory certificate To EN 10204-2.2 C14 9 9 9 Output signal can be set to upper limit of 22.0 mA D05 9 9 9 9 9 9 Setting of pressure indication in pressure Y21 units Specify in plain text (standard setting: mA): Y21: mbar, bar, kPa, MPa, psi, ... Note: The following pressure units can be selected: bar, mbar, mm H2O*), inH2O*), ftH2O*), mmHG, inHG, psi, Pa, kPa, MPa, g/cm2, kg/cm2, Torr, ATM or % *) ref. temperature 20 °C 9 9 Setting of pressure indication in Y22 + non-pressure units Y01 Specify in plain text: Y22: ..... up to ..... l, m3, m, USg, ... (specification of measuring range in pressure units "Y01" is essential, unit with max. 5 characters) 9 9 9 9 M12 cable sockets (metal) Rating plate inscription (instead of German) Mounting • Weldable sockets for standard 1½" threaded P01 connection • Weldable socket for mini bolt connection 1" P02 (incl. screw 5/16-18 UNC-2B and washer) Preset bus address Max. 8 characters, specify in plain text: Y25: ........... Y25 Only "Y01" and "Y21" can be factory preset 9 = available Ordering example Item line: 7MF4133-1DB20-1AB7-Z B line: A22 + Y01 + Y21 C line: Y01: 1 ... 10 bar (14.5 ... 145 psi) C line: Y21: bar (psi) 2/56 Siemens FI 01 · 2009 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage pressure for the paper industry DS III series with PMC connection ■ Dimensional drawings 144 (567) Ø 80 (3.15) 20 (0.8) 74 (2.9) 1 2 3 4 5 6 7 1) 2) 7 H2 1 2 2 Space for rotation of housing 90 (3.6)2) 6 3 4 1) 5 1) 100 (3.94) 50 (1.97) approx. 30 (1.18) 51 (2.0) H1 = approx. 130 (5.12) 15 (0.6) Process connection: PMC standard Blanking plug Electrical connection: - screwed gland M20x1,5 - screwed gland ½-14 NPT Terminal side Electronics side, digital display (longer overall length for cover with window) Protective cover over keys Screw cover safety bracket (only for explosion-proof enclosure, not shown in the drawing) Allow approx. 20 mm (0.79 inch) thread length in addition 92 mm (3.6 inch) for minimum distance to permit rotation with indicator SITRANS P DS III pressure transmitters for gage pressure, with PMC connection, dimensions in mm (inch) The diagram shows a SITRANS P DS III with an example of a flange. In this drawing the height is subdivided into H1 and H2. PMC Style standard DN PN ∅D H2 40.9 mm (1.6") Approx. 36.8 mm (1.4’’) ∅D H2 26.3 mm (1.0") Approx. 33.1 mm (1.3’’) + H1 = Height of the SITRANS P DS III up to a defined cross-section H2 = Height of the flange up to this defined cross-section Only the height H2 is indicated in the dimensions of the flanges. ' PMC Style minibolt DN PN + 0[ ' 2ULQJVXUIDFH ERUHKROHPPಯZLWKRXWEXUU PMC Style standard (left) and PMC Style minibolt (right) weldable sockets, dimensions in mm (inch) Material: Stainless steel, mat. No. 1.4404 / 316L Siemens FI 01 · 2009 2/57 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage pressure for the paper industry SITRANS P300 with PMC connection ■ Technical specifications SITRANS P300 for gage pressure with PMC connection for the paper industry HART 2 PROFIBUS PA Input Measured variable Gage pressure (flush-mounted) Spans (infinitely adjustable) or nominal measuring range and max. permissible test pressure Span Max. perm. test pressure Nominal measuring range Max. perm. test pressure 0.01 ... 1 bar g (0.15 ... 14.5 psi g) 6 bar g (87 psi g) 1 bar g (14.5 psi g) 6 bar g (87 psi g) 0.04 ... 4 bar g (0.58 ... 58 psi g) 10 bar g (145 psi g) 4 bar g (58 psi g) 10 bar g (145 psi g) 0.16 ... 16 bar g (2.3 ... 232 psi g) 32 bar g (464 psi g) 16 bar g (232 psi g) 32 bar g (464 psi g) Depending on the process connection, the span may differ from these values Depending on the process connection, the nominal measuring range may differ from these values Lower measuring limit • Measuring cell with silicone oil 100 mbar a (1.45 psi a) Upper measuring limit • Measuring cell with silicone oil 100% of max. span 100% of the max. nominal measuring range Output signal 4 ... 20 mA Digital PROFIBUS PA signal Physical bus - IEC 61158-2 With polarity reversal protection No Yes Output Electrical damping T63 (step width 0.1 s) Set to 0.1 s (0 ... 100 s) Accuracy To EN 60770-1 Reference conditions (All error data refer always refer to the set span) Increasing characteristic, start-of-scale value 0 bar, stainless steel seal diaphragm, measuring cell with silicone oil, room temperature 25 °C (77 °F), span ratio (r = max. span/set span) Measurement deviation with cut-off point setting, including hysteresis and repeatability. ≤ 0,075% Linear characteristic curve • r ≤ 10 ≤ (0.0029 ⋅ r + 0.071)% • 10 < r ≤ 30 ≤ (0.0045 ⋅ r + 0.071)% • 30 < r ≤ 100 ≤ (0.005 ⋅ r + 0.05)% Settling time T63 without electrical damping Approx. 0.2 s Long-term drift at ±30 °C (±54 °F) ≤ (0.25 ⋅ r)%/5 years ≤ 0.25%/5 years • at -10 ... +60 °C (14 ... 140 °F) ≤ (0.1 ⋅ r + 0.2)% ≤ 0,3% • at -40 ... -10 °C and +60 ... +85 °C (-40 ... 14 °F and 140 ... 185 °F) ≤ (0.1 ⋅ r + 0.15)%/10 K ≤ 0.25%/10 K Influence of ambient temperature Influence of the medium temperature (only with front-flush diaphragm) • Temperature difference between medium temperature and ambient temperature 3 mbar/10 K (0.04 psi/10 K) Rated operating conditions Installation conditions Ambient temperature Observe the temperature class in areas subject to explosion hazard. • Measuring cell with silicone oil -40 ... +85 °C (-40 ... +185 °F) • Digital display -30 ... +85 °C (-22 ... +185 °F) • Storage temperature -50 ... +85 °C (-58 ... +185 °F) Climatic class Condensation Permissible Degree of protection to EN 60529 IP65, IP68, NEMA X, enclosure cleaning, resistant to lyes, steam to 150° C (302 °F) Electromagnetic compatibility • Emitted interference and interfer. immunity 2/58 Siemens FI 01 · 2009 To EN 61326 and NAMUR NE 21 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage pressure for the paper industry SITRANS P300 with PMC connection SITRANS P300 for gage pressure with PMC connection for the paper industry HART PROFIBUS PA Medium conditions Process temperature • Measuring cell with silicone oil 2 -40 ... +100 °C (-40 ... +212 °F) Design Weight (without options) Approx. 1 kg (2.2 lb) Housing material Stainless steel, mat. No. 1.4301/304 Material of parts in contact with the medium • Seal diaphragm Hastelloy C276, mat. No. 2.4819 • Measuring cell filling Silicone oil Power supply UH Terminal voltage on transmitter 10.5 ... 42 V DC for intrinsically safe operation: 10.5 ... 30 V DC Supplied through bus Separate power supply - Not necessary Bus voltage • Without EEx - 9 ... 32 V • For intrinsically-safe operation - 9 ... 24 V Current consumption • Max. basic current - 12.5 mA • Startup current ≤ basic current - Yes • Max. fault current in the event of a fault - 15.5 mA Fault disconnection electronics (FDE) - Available Certificate and approvals Classification according to pressure equipment directive (DRGL 97/23/EC) For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of Article 3, paragraph 3 (sound engineering practice) Explosion protection Intrinsic safety "i" PTB 05 ATEX 2048 Identification Ex II 1/2 G EEx ia/ib IIB/IIC T4, T5, T6 Permissible ambient temperature • Temperature class T4 -40 ... +85 °C (-40 ... +185 °F) • Temperature class T5 -40 ... +70 °C (-40 ... +158 °F) • Temperature class T6 -40 ... +60 °C (-40 ... +140 °F) Connection To certified intrinsically-safe circuits with maximum values: Ui = 30 V, Ii = 100 mA, Pi = 750 mW, Ri = 300 Ω To certified intrinsically-safe circuits with maximum values: FISCO supply unit: Ui = 17.5 V, Ii = 380 mA, Pi = 5.32 W Linear barrier: Ui = 24 V, Ii = 250 mA, Pi = 1.2 W Effective inner capacitance: Ci = 6 nF Ci = 1.1 nF Effective inner inductance: Li = 0.4 mH Li ≤ 7 μH Explosion protection to FM for USA and Canada (cFMUS) • Identification (DIP) or (IS); (NI) Certificate of Compliance 3025099 CL I, DIV 1, GP ABCD T4 ... T6; CL II, DIV 1, GP EFG; CL III; CL I, ZN 0/1 AEx ia IIC T4 ... T6; CL I, DIV 2, GP ABCD T4 ... T6; CL II, DIV 2, GP FG; CL III • Identification (DIP) or (IS) Certificate of Compliance 3025099C CL I, DIV 1, GP ABCD T4 ... T6; CL II, DIV 1, GP EFG; CL III; Ex ia IIC 4 ... T6; CL I, DIV 2, GP ABCD T4 ... T6; CL II, DIV 2, GP FG; CL III Siemens FI 01 · 2009 2/59 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage pressure for the paper industry SITRANS P300 with PMC connection SITRANS P300 for gage pressure with PMC connection for the paper industry Communication FOUNDATION Fieldbus Function blocks HART communication 2 HART communication 230 ... 1100 Ω Protocol HART Version 5.x Software for computer SIMATIC PDM 3 function blocks analog input, 1 function block PID • Analog input - Adaptation to customer-specif- Yes, linearly rising or falling charic process variables acteristic - Electrical damping T63 , adjust- 0 ... 100 s able PROFIBUS PA communication Simultaneous communication with 4 master class 2 (max.) - Simulation function Output/input (can be locked within the device with a bridge) The address can be set using - Failure mode Can be parameterized (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively - Square-rooted characteristic for flow measurement Yes configuration tool Local operation (standard setting Address 126) Cyclic data usage • Output byte One measuring value: 5 bytes Two measuring values: 10 bytes • Input byte Register operating mode: 1 bytes Reset function due to metering. 1 bytes • PID • Physical block 1 Resource block Device profile PROFIBUS PA Profile for Process Control Devices Version 3.0, Class B Transducer blocks 1 transducer block Pressure with calibration, 1 transducer block LCD Function blocks 2 • Pressure transducer block - Can be calibrated by applying Yes two pressures • Analog input - Adaptation to customer-specific Linearly rising or falling characterprocess variables istic - Electrical damping T63 0 ... 100 s adjustable - Simulation function Input /Output - Limit monitoring One upper and lower warning limit and one alarm limit respectively • Register (totalizer) Can be reset and preset Optional direction of counting Simulation function of the register output - Limit monitoring One upper and lower warning limit and one alarm limit respectively • Physical block 1 Transducer blocks 2 • Pressure transducer block - Monitoring of sensor limits Yes - Specification of a container characteristic with Max. 31 nodes - Characteristic Linear - Simulation function Available • Transducer block "Electronic temperature" - Simulation function 2/60 Siemens FI 01 · 2009 Standard FF function block Available - Monitoring of sensor limits Yes - Simulation function: Measured Constant value or over parameterpressure value, sensor temper- izable ramp function ature and electronics temperature © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage pressure for the paper industry SITRANS P300 with PMC connection Order No. Selection and Ordering data Further designs 4 ... 20 mA/HART F) 7 M F 8 1 2 3 - PROFIBUS PA F) 7 M F 8 1 2 4 - FOUNDATION Fieldbus (FF) F) 7 M F 8 1 2 5 - Measuring cell filling Silicone oil Inert liquid Span 1 bar g 4 bar g 16 bar g Measuring cell cleaning Standard Cleanliness level 2 to DIN 25410 (14.5 psi g) (58 psi g) (232 psi g) Stainless steel Process connection • PMC Style Standard: Thread 1½" • PMC Style Mini bolt: 1" front-flush (min. span: 500 mbar (7.25 psi), can not be ordered with mit 1-bar (14.5 psi) measuring cell (Option B)) Non-wetted parts materials • Stainless steel, deep-drawn and electrolytically polished Version • Standard version Explosion protection • None • With ATEX, Type of protection: - "Intrinsic safety (EEx ia)" • Zone 20/21/221) • Ex nA/nL (zone 2)2) • With FM + CSA, Type of protection: - "Intrinsic Safe (is)" (planned) Cable socket for M12 plug • Metal • Stainless steel • German • French • Spanish • Italian B10 B12 B13 B14 9 9 9 9 9 9 9 9 9 9 9 9 English rating plate Pressure units in inH2O or psi B21 9 9 9 Quality inspection certificate (Factory cali- C11 bration) to IEC 60770-2 9 9 9 Acceptance test certificate To EN 10204-3.1 C12 9 9 9 Factory certificate To EN 10204-2.2 C14 9 9 9 Set output signal to upper limit of 22.0 mA D05 9 9 9 Type of protection IP68 9 9 9 9 9 9 9 9 9 B C D B 2 3 D12 Mounting • Weldable sockets for standard 1½" threaded P01 connection • Weldable socket for mini bolt connection 1" P02 (incl. screw 5/16-18 UNC-2B and washer) 4 1 Additional data Add "-Z" to Order No. and specify Order code. A M • With display (setting acc. to specifications, Order code "Y21" or "Y22" required), lid with glass pane Y01 9 Measuring point number (TAG No.) Y15 Max. 16 characters, specify in plain text: Y15: ...... 9 9 9 Measuring point text Y16 Max. 27 characters, specify in plain text: Y16: ...... 9 9 9 Entry of HART address (TAG) Max. 8 characters, specify in plain text: Y17: ........................................... Y17 9 Setting of pressure indication in pressure units Specify in plain text (standard setting: mA): Y21: mbar, bar, kPa, MPa, psi, ... Note: The following pressure units can be selected: bar, mbar, mm H2O*), inH2O*), ftH2O*), mmHG, inHG, psi, Pa, kPa, MPa, g/cm2, kg/cm2, Torr, ATM or % *) ref. temperature 20 °C Y21 9 9 9 9 9 Measuring range to be set Specify in plain text (max. 5 digits): Y01: ... up to ... mbar, bar, kPa, MPa, psi B C E • With display and keys, lid with glass pane (setting on HART devices: mA, on PROFIBUS PA and FOUNDATION Fieldbus devices: pressure unit) A B C F G H J 1 2 6 7 Power supply units see "SITRANS I power supply units and isolation amplifiers". Included in delivery of the device: • Brief instructions (Leporello) • CD-ROM with detailed documentation • Sealing ring 4) 9 9 1 3 • With display and keys, closed lid 3) 9 9 A50 A51 Rating plate inscription (instead of English) Display • Without display, with keys, closed lid3) 2) FF 77777 - 7777 Electrical connection / cable entry • Screwed gland M20x1.5 (Polyamide)3) • Screwed gland M20x1.5 (metal) • Screwed gland M20x1.5 (stainless steel) • M12 connector (without cable socket) • M12 connector (stainless steel, without cable socket) • ½-14 NPT thread, metal4) • ½-14 NPT thread, stainless steel4) 1) HART PA Add "-Z" to Order No. and specify Order code. Wetted parts materials Seal diaphragm Measuring cell Hastelloy Order code Selection and Ordering data SITRANS P300 pressure transmitters with PMC connection, single-chamber measuring housing, rating plate inscription in English Can only be ordered in conjunction with electrical connection Option A. Can only be ordered in conjunction with electrical connection Option B, C, F or G. Only together with HART electronics. Without cable gland. Setting of pressure indication in non-pres- Y22 + sure units Y01 Specify in plain text: 3 Y22: ..... up to ..... l, m , m, USg, ... (specification of measuring range in pressure units "Y01" is essential, unit with max. 5 characters) Preset bus address Specify in plain text: Y25: ..................... 9 Y25 Only "Y01" and "Y21" can be factory preset 9 = available F) Subject to export regulations AL: 9I999, ECCN: N. Siemens FI 01 · 2009 2/61 2 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage pressure for the paper industry SITRANS P300 with PMC connection ■ Dimensional drawings ෘ + $SSUR[ + $SSUR[ 2 r SITRANS P300 pressure transmitters for gage pressure, with PMC connection, dimensions in mm (inch) The diagram shows a SITRANS P300 with an example of a flange. In this drawing the height is subdivided into H1 and H2. PMC Style Standard DN H2 = Height of the flange up to this defined cross-section Only the height H2 is indicated in the dimensions of the flanges. DN ' 2ULQJVXUIDFH ERUHKROHPPಯZLWKRXWEXUU PMC Style Standard (left) and PMC Style Minibolt (right) weldable sockets, dimensions in mm (inch) Material: Stainless steel, mat. No. 1.4404 / 316L 2/62 Siemens FI 01 · 2009 H2 40.4 mm (1.6") Approx. 36.8 mm (1.4’’) ∅D H2 26.3 mm (1.0") Approx. 33.1 mm (1.3’’) PMC Style Minibolt + ∅D ' 0[ PN + H1 = Height of the SITRANS P300 up to a defined cross-section PN © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III, DS III PA and DS III FF series Technical description ■ Overview 2 SITRANS P pressure transmitters, DS III series, are digital pressure transmitters featuring extensive user-friendliness and high accuracy. The parameterization is performed using control keys, over HART communication, PROFIBUS-PA or FOUNDATION Fieldbus interface. Extensive functionality enables the pressure transmitter to be precisely adapted to the plant’s requirements. Operation is very simple in spite of the numerous setting options. Transmitters with type of protection "Intrinsic safety" and "Explosion-proof" may be installed within potentially explosive atmospheres (zone 1) or in zone 0. The transmitters are provided with an EC type examination certificate and comply with the corresponding harmonized European standards (ATEX). The transmitters can be equipped with various designs of remote seals for special applications such as the measurement of highly viscous substances. Various versions of the DS III pressure transmitters are available for measuring: • Gage pressure • Absolute pressure • For differential pressure transmitters • Filling level • Mass level • Volume level • Volume flow • Mass flow ■ Benefits • High quality and long life • High reliability even under extreme chemical and mechanical loads • For aggressive and non-aggressive gases, vapors and liquids • Extensive diagnosis and simulation functions • Separate replacement of measuring cell and electronics without recalibration • Minimum conformity error • Small long-term drift • Wetted parts made of high-grade materials (e.g. stainless steel, Hastelloy, gold, Monel, tantalum) • Infinitely adjustable span from 0.01 mbar to 400 mbar for DS III with HART communication • Nominal measuring range from 1 to 400 bar for DS III PA (PROFIBUS PA) and FF (FOUNDATION Fieldbus) • High measuring accuracy • Parameterization over control keys and HART communication, PROFIBUS PA communication or FOUNDATION Fieldbus interface. ■ Application The pressure transmitters of the DS III series, can be used in industrial areas with extreme chemical and mechanical loads. Electromagnetic compatibility in the range 10 kHz to 1 GHz makes the DS III pressure transmitters suitable for locations with high electromagnetic emissions. Pressure transmitters with type of protection "Intrinsic safety" and "Explosion-proof" may be installed within potentially explosive atmospheres (zone 1) or in zone 0. The pressure transmitters are provided with an EC type examination certificate and comply with the corresponding harmonized European standards (ATEX). Pressure transmitters with the type of protection "Intrinsic safety" for use in zone 0 may be operated with power supply units of category "ia" and "ib". The transmitters can be equipped with various designs of remote seals for special applications such as the measurement of highly viscous substances. The pressure transmitter can be operated locally over 3 control keys or programmed externally over HART communication or over PROFIBUS PA or FOUNDATION Fieldbus interface. Siemens FI 01 · 2009 2/63 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III, DS III PA and DS III FF series Technical description 2 Pressure transmitter for gage pressure • Measured variable: Gage pressure of aggressive and non-aggressive gases, vapors and liquids. • Span (infinitely adjustable) for DS III HART: 0.01 ... 400 bar g (0.145 ... 5802 psi g) • Nominal measuring range for DS III PA and FF: 1 ... 400 bar g (14.5 ... 5802 psi g) ■ Design Pressure transmitters for absolute pressure • Measured variable: Absolute pressure of aggressive and nonaggressive gases, vapors and liquids. • Span (infinitely adjustable) for DS III HART: 8.3 mbar a ... 100 bar a (0.12 ... 1450 psi a) • Nominal measuring range for DS III PA and FF: 250 mbar a ... 100 bar a (3.63 ... 1450 psi a) • There are two series: - Gage pressure series - Differential pressure series Pressure transmitters for differential pressure and flow • Measured variables: - Differential pressure - Small positive or negative pressure - Flow q ~ √Δp (together with a primary differential pressure device (see Chapter "Flow Meters")) • Span (infinitely adjustable) for DS III HART: 1 mbar ... 30 bar (0.0145 ... 435 psi) • Nominal measuring range for DS III PA and FF: 20 mbar ... 30 bar (0.29 ... 435 psi) Pressure transmitters for level • Measured variable: Level of aggressive and non-aggressive liquids in open and closed vessels. • Span (infinitely adjustable) for DS III HART: 25 mbar ... 5 bar (0.363 ... 72.5 psi) • Nominal measuring range for DS III PA and FF: 250 mbar ... 5 bar (3.63 ... 72.5 psi) • Nominal diameter of the mounting flange - DN 80 or DN 100 - 3 inch or 4 inch In the case of level measurements in open containers, the lowpressure connection of the measuring cell remains open (measurement "compared to atmospheric"). In the case of measurements in closed containers, the lowerpressure connection has to be connected to the container in order to compensate the static pressure. The wetted parts are made from a variety of materials, depending on the degree of corrosion resistance required. Front view The transmitter consists of various components depending on the order. The possible versions are listed in the ordering information. The components described below are the same for all transmitters. The rating plate (3, Figure "Front view") with the Order No. is located on the side of the housing. The specified number together with the ordering information provide details on the optional design details and on the possible measuring range (physical properties of built-in sensor element). The approval label is located on the opposite side. The housing is made of die-cast aluminium or stainless steel precision casting. A round cover is screwed on at the front and rear of the housing. The front cover (6) can be fitted with a viewing pane so that the measured values can be read directly on the digital display. The inlet (4) for the electrical connection is located either on the left or right side. The unused opening on the opposite side is sealed by a blanking plug. The protective earth connection is located on the rear of the housing. The electrical connections for the power supply and screen are accessible by unscrewing the rear cover. The bottom part of the housing contains the measuring cell with process connection (1). The measuring cell is prevented from rotating by a locking screw (8). As the result of this modular design, the measuring cell and the electronics can be replaced separately from each other. The set parameter data are retained. At the top of the housing is a plastic cover (5), which hides the input keys. 2/64 Siemens FI 01 · 2009 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III, DS III PA and DS III FF series Technical description ■ Function Operation of the electronics with PROFIBUS PA communication Operation of the electronics with PROFIBUS PA communication 9 8 M 2 3 4 mC 5 mC 10 5 4 3 2 2 7 PA interface IA, UH EEPROM 7 6 HART interface Electronics 6 1 Electronics 1 Pe 1 2 3 4 5 6 7 8 9 10 IA UH Pe Sensor EEPROM 6 Sensor Measuring cell Measuring cell sensor Instrument amplifier Analog-to-digital converter Microcontroller Digital-to-analog converter One non-volatile memory each in the measuring cell and electronics HART interface Three input keys (local operation) Digital display Diode circuit and connection for external ammeter Output current Power supply Input variable Function diagram of the electronics The bridge output voltage created by the sensor (1, Figure "Function diagram of the electronics") is amplified by the instrument amplifier (2) and digitized in the analog-to-digital converter (3). The digital information is evaluated in a microcontroller, its linearity and temperature response corrected, and converted in a digital-to-analog converter (5) into an output current of 4 to 20 mA. The diode circuit (10) protects against incorrect polarity. The data specific to the measuring cell, the electronics data, and the parameter data are stored in the two non-volatile memories (6). The one memory is coupled to the measuring cell, the other to the electronics. As the result of this modular design, the electronics and the measuring cell can be replaced separately from each other. Using the 3 input keys (8) you can parameterize the pressure transmitter directly at the point of measurement. The input keys can also be used to control the view of the results, the error messages and the operating modes on the digital display (9). 6 pe 1 2 3 4 5 6 7 Power supply unit Coupler 11 12 BusMaster EEPROM EEPROM Power supply 10 PROFIBUS-DP 0 0 00 0 00 PROFIBUS-PA 8 0 0 00 0 00 M 9 Measuring cell Measuring cell sensor Instrument amplifier Analog-to-digital converter Microcontroller Electrical isolation One non-volatile memory each in the measuring cell and electronics PROFIBUS-PA interface 8 9 10 11 12 Three input keys (local operation) Digital display Power supply DP/PA coupler or link Bus master pe Input variable Function diagram of the electronics The bridge output voltage created by the sensor (1, Figure "Function diagram of the electronics") is amplified by the instrument amplifier (2) and digitized in the analog-to-digital converter (3). The digital information is evaluated in the microcontroller, its linearity and temperature response corrected, and provided on the PROFIBUS PA through an electrically isolated PA interface (7). The data specific to the measuring cell, the electronics data, and the parameter data are stored in the two non-volatile memories (6). The first memory is linked with the measuring cell, the second with the electronics. This modular design means that the electronics and the measuring cell can be replaced separately from one another. Using the three input keys (8) you can parameterize the pressure transmitter directly at the point of measurement. The input keys can also be used to control the view of the results, the error messages and the operating modes on the digital display (9). The results with status values and diagnostic values are transferred by cyclic data transmission on the PROFIBUS PA. Parameterization data and error messages are transferred by acyclic data transmission. Special software such as SIMATIC PDM is required for this. The HART modem (7) permits parameterization using a protocol according to the HART specification. The pressure transmitters with spans ≤ 63 bar measure the input pressure compared to atmosphere, transmitters with spans ≥ 160 bar compared to vacuum. Siemens FI 01 · 2009 2/65 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III, DS III PA and DS III FF series Technical description Mode of operation of the FOUNDATION Fieldbus electronics 0 0 00 0 00 M 2 2 Measuring cell for gage pressure 9 8 Mode of operation of the measuring cells 3 4 5 mC EEPROM 7 FF interface Power supply 10 5 4 3 1 Power supply unit 6 Coupler Electronics 1 pe 1 2 3 4 5 6 7 EEPROM p e Measuring cell for gage pressure, function diagram Measuring cell Measuring cell sensor Instrument amplifier Analog-to-digital converter Microcontroller Electrical isolation One non-volatile memory each in the measuring cell and electronics FF interface 8 9 10 Three input keys (local operation) Digital display Power supply pe Input variable Function diagram of the electronics The bridge output voltage created by the sensor (1, Figure "Function diagram of the electronics") is amplified by the instrument amplifier (2) and digitized in the analog-to-digital converter (3). The digital information is evaluated in the microcontroller, its linearity and temperature response corrected, and provided on the FOUNDATION Fieldbus through an electrically isolated FOUNDATION Fieldbus Interface (7). The data specific to the measuring cell, the electronics data, and the parameter data are stored in the two non-volatile memories (6). The one memory is coupled to the measuring cell, the other to the electronics. As the result of this modular design, the electronics and the measuring cell can be replaced separately from each other. Using the three input keys (8) you can parameterize the pressure transmitter directly at the point of measurement. The input keys can also be used to control the view of the results, the error messages and the operating modes on the digital display (9). The results with status values and diagnostic values are transferred by cyclic data transmission on the FOUNDATION Fieldbus. Parameterization data and error messages are transferred by acyclic data transmission. Special software such as National Instruments Configurator is required for this. 2/66 Measuring cell Process connection Seal diaphragm Filling liquid Silicon pressure sensor Pressure as input variable 2 6 Sensor 1 2 3 4 5 pe Siemens FI 01 · 2009 The pressure pe is applied through the process connection (2, Figure "Measuring cell for gage pressure, function diagram) to the measuring cell (1). This pressure is subsequently transmitted further through the seal diaphragm (3) and the filling liquid (4) to the silicon pressure sensor (5) whose measuring diaphragm is then flexed. This changes the resistance of the four piezo-resistors fitted in the diaphragm in a bridge circuit. This change in resistance results in a bridge output voltage proportional to the input pressure. Measuring cell for gage pressure, with front-flush diaphragm for paper industry 5 4 1 1 2 3 4 5 pe Measuring cell Process connection Seal diaphragm Filling liquid Silicon pressure sensor Pressure as input variable 2 3 p e Measuring cell for gage pressure, with front-flush diaphragm for paper industry, function diagram The pressure pe is applied through the process connection (2, Figure "Measuring cell for gage pressure, with front-flush diaphragm for paper industry, function diagram") to the measuring cell (1). This pressure is subsequently transmitted further through the seal diaphragm (3) and the filling liquid (4) to the silicon pressure sensor (5) whose measuring diaphragm is then flexed. This changes the resistance of the four piezo-resistors fitted in the diaphragm in a bridge circuit. This change in resistance results in a bridge output voltage proportional to the input pressure. © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III, DS III PA and DS III FF series Technical description Measuring cell for absolute pressure from gage pressure series Measuring cell for differential pressure and flow 2 3 4 1 2 3 4 5 6 7 5 4 1 3 1 1 2 3 4 5 pe 1 5 + Measuring cell Process connection Seal diaphragm Filling liquid Silicon absolute pressure sensor Absolute pressure as input variable 7 6 Measuring cell for differential pressure and flow, function diagram 2 pe - Seal diaphragm O-ring Overload diaphragm Silicon pressure sensor Process flange Body of measuring cell Filling liquid Measuring cell for absolute pressure from the pressure series, function diagram The absolute pressure pe is transmitted through the seal diaphragm (3, Figure "Measuring cell for absolute pressure from the gage pressure series, function diagram") and the filling liquid (4) to the silicon absolute pressure sensor (5) whose measuring diaphragm is then flexed. This changes the resistance of the four piezo-resistors fitted in the diaphragm in a bridge circuit. This change in resistance results in a bridge output voltage proportional to the input pressure. The differential pressure is transmitted through the seal diaphragms (1, Figure "Measuring cell for differential pressure and flow, function diagram") and the filling liquid (7) to the silicon pressure sensor (4). The measuring diaphragm is flexed by the applied differential pressure. This changes the resistance of the four piezo-resistors fitted in the diaphragm in a bridge circuit. This change in resistance results in a bridge output voltage proportional to the absolute pressure. An overload diaphragm is installed to provide protection from overloads. If the measuring limits are exceeded, the overload diaphragm (2) is flexed until the seal diaphragm rests on the body of the measuring cell (7), thus protecting the silicon pressure sensor from overloads. Measuring cell for level Measuring cell for absolute pressure from differential pressure series 3 2 3 4 5 pe 1 6 8 1 2 3 4 5 6 7 8 pe Reference vacuum Overload diaphragm Silicon pressure sensor O-ring Process flange Seal diaphragm Body of measuring cell Filling liquid Absolute pressure as input variable 7 4 5 6 7 2 8 + 1 1 2 3 4 5 10 9 6 7 8 9 10 Flange with tube Seal diaphragm on mounting flange Seal diaphragm Body of measuring cell Overload diaphragm Silicon pressure sensor O-ring Process flange Filling liquid Capillary with filling liquid of mounting flange Measuring cell for absolute pressure from differential pressure series, function diagram The input pressure pe is transmitted through the seal diaphragm (6, Figure "Measuring cell for absolute pressure from differential pressure series, function diagram") and the filling liquid (8) to the silicon pressure sensor (3). The difference in pressure between the input pressure pe and the reference vacuum (1) on the low-pressure side of the measuring cell flexes the measuring diaphragm. The resistance of the four piezo-resistors fitted in the diaphragm in a bridge circuit thus changes. This change in resistance results in a bridge output voltage proportional to the absolute pressure. An overload diaphragm is installed to provide protection from overloads. If the measuring limits are exceeded, the overload diaphragm (2) is flexed until the seal diaphragm rests on the body of the measuring cell (7), thus protecting the silicon pressure sensor from overloads. Measuring cell for level, function diagram The input pressure (hydrostatic pressure) acts hydraulically on the measuring cell through the seal diaphragm on the mounting flange (2, Figure "Measuring cell for level, function diagram"). This differential pressure is subsequently transmitted further through the measuring cell (3) and the filling liquid (9) to the silicon pressure sensor (6) whose measuring diaphragm is then flexed. This changes the resistance of the four piezo-resistors fitted in the diaphragm in a bridge circuit. This change in resistance results in a bridge output voltage proportional to the differential pressure. An overload diaphragm is installed to provide protection from overloads. If the measuring limits are exceeded, the overload diaphragm (2) is flexed until the seal diaphragm rests on the body Siemens FI 01 · 2009 2/67 2 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III, DS III PA and DS III FF series Technical description of the measuring cell (7), thus protecting the silicon pressure sensor from overloads. Parameterization DS III 2 Depending on the version, there are a range of options for parameterizing the pressure transmitter and for setting or scanning the parameters. Parameterization using the input keys (local operation) With the input keys you can easily set the most important parameters without any additional equipment. Parameterization using HART communication Parameterization using HART communication is performed with a HART communicator or a PC. 1) 2) Cancel apart from write protection Only differential pressure Diagnostic functions for DS III HART • Zero correction display • Event counter • Limit transmitter • Saturation alarm • Slave pointer • Simulation functions • Maintenance timer Available physical units of display for DS III HART Table style: Technical specifications 2 + 230 ... 1100 W SITRANS P transmitter Power supply HART communicator Physical variable Physical dimensions Pressure (setting can also be made in the factory) Pa, MPa, kPa, bar, mbar, torr, atm, psi, g/cm2, kg/cm2, inH2O, inH2O (4 °C), mmH2O, ftH2O (20 °C), inHg, mmHg Level (height data) m, cm, mm, ft, in Volume m3, dm3, hl, yd3, ft3, in3, US gallon, lmp. gallon, bushel, barrel, barrel liquid Mass g, kg, t, lb, Ston, Lton, oz Communication between a HART communicator and a pressure transm. Volume flow When parameterizing with the HART communicator, the connection is made directly to the 2-wire system. m3/d, m3/h, m3/s, l/min, l/s, ft3/d, ft3/min, ft3/s, US gallon/min, US gallon/s Mass flow t/d, t/h, t/min, kg/d, kg/h, kg/min, kg/s, g/d, g/h, g/min, g/s, lb/d, lb/h, lb/min, lb/s, LTon/d, LTon/h, STon/d, STon/h, STon/min 230 ... 500 W SITRANS P transmitter Power supply PC or laptop HART modem Temperature K, °C, °F, °R Miscellaneous %, mA Parameterization through PROFIBUS PA interface Fully digital communication through PROFIBUS PA, profile 3.0, is particularly user-friendly. The PROFIBUS puts the DS III PA is in connection with a process control system, e.g. SIMATIC PSC 7. Communication is possible even in a potentially explosive environment. RS 232 HART communication between a PC communicator and a pressure transmitter When parameterizing with a PC, the connection is made through a HART modem. The signals needed for communication in conformity with the HART 5.x or 6.x protocols are superimposed on the output current using the Frequency Shift Keying (FSK) method. Adjustable parameters, DS III HART Parameters Input keys HART com(DS III HART) munication Start of scale x x Full-scale value x x Electrical damping x Start-of-scale value without application of a pressure ("Blind setting") x For parameterization through PROFIBUS you need suitable software, e.g. SIMATIC PDM (Process Device Manager). Parameterization through FOUNDATION Fieldbus Interface Fully digital communication through FOUNDATION Fieldbus is particularly user-friendly. Through the FOUNDATION Fieldbus the DS III FF is connected to a process control system. Communication is possible even in a potentially explosive environment. For parameterization through the FOUNDATION Fieldbus you need suitable software, e.g. National Instruments Configurator. Adjustable parameters for DS III PA and FF Parameters Input keys PROFIBUS PA and (DS III HART) FOUNDATION Fieldbus interface x Electrical damping x x x Zero adjustment (correction of x position) x Full-scale value without application of a x pressure ("Blind setting") x Key and/or function disabling x x Zero adjustment x Source of measured-value dis- x play x Physical dimension of display x x Position of decimal point x x Bus address x x x2) Adjustment of characteristic x x Input of characteristic Freely-programmable LCD x Freely-programmable LCD x Diagnostics functions x Diagnostics functions x x Current transmitter x x Fault current x x Disabling of keys, write protection x x1) Type of dimension and actual dimension x Characteristic (linear / square-rooted) Input of characteristic 2/68 Siemens FI 01 · 2009 x2) x x x © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III, DS III PA and DS III FF series Technical description Diagnostic functions for DS III PA and FF • Event counter • Slave pointer • Maintenance timer • Simulation functions • Display of zero correction • Limit transmitter • Saturation alarm 2 Physical dimensions available for the display Physical variable Physical dimensions Pressure (setting can also be made in the factory) MPa, kPa, Pa, bar, mbar, torr, atm, psi, g/cm2, kg/cm2, mmH2O, mmH2O (4 °C), inH2O, inH20 (4 °C), ftH2O (20 °C), mmHg, inHg Level (height data) m, cm, mm, ft, in, yd Volume m3, dm3, hl, yd3, ft3, in3, US gallon, lmp. gallon, bushel, barrel, barrel liquid Volume flow m3/s, m3/min, m3/h, m3/d, l/s, l/min, l/h, l/ d, Ml/d, ft3/s, ft3/min, ft3/h, ft3/d, US gallon/s, US gallon/min, US gallon/h, US gallon/d, bbl/s, bbl/min, bbl/h, bbl/d Mass flow g/s, g/min, g/h, g/d, kg/s, kg/min, kg/h, kg/d, t/s, t/min, t/h, /t/d, lb/s, lb/min, lb/h, lb/d, STon/s, STon/min, STon/h, STon/d, LTon/s, LTon/min, LTon/h, LTon/d Total mass flow t, kg, g, lb, oz, LTon, STon Temperature K, °C, °F, °R Miscellaneous % Siemens FI 01 · 2009 2/69 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for gage pressure ■ Technical specifications SITRANS P, DS III series for gage pressure HART 2 PROFIBUS PA or FOUNDATION Fieldbus Input Measured variable Gage pressure Spans (infinitely adjustable) or nominal measuring range and max. permissible test pressure Span Max. perm. test pressure Nominal measuring range Max. perm. test pressure 0.01 ... 1 bar g (0.145 ... 14.5 psi g) 6 bar g (87 psi g) 1 bar g (14.5 psi g) 6 bar g (87 psi g) 0.04 ... 4 bar g (0.58 ... 58 psi g) 10 bar g (145 psi g) 4 bar g (58 psi g) 10 bar g (145 psi g) 0.16 ... 16 bar g (2.23 ... 232 psi g) 32 bar g (464 psi g) 16 bar g (232 psi g) 32 bar g (464 psi g) 0.6 ... 63 bar g (9.14 ... 914 psi g) 100 bar g (1450 psi g) 63 bar g (914 psi g) 100 bar g (1450 psi g) 1.6 ... 160 bar g (23.2 ... 2320 psi g) 250 bar g (3626 psi g) 160 bar g (2320 psi g) 250 bar g (3626 psi g) 4.0 ... 400 bar g (58 ... 5802 psi g) 600 bar g (8700 psi g) 400 bar g (5802 psi g) 600 bar g (8700 psi g) 7.0 ... 700 bar g (102 ... 10153 psi g) 800 bar g (11603 psi g) 700 bar g (10153 psi g) 800 bar g (11603 psi g) Lower measuring limit • Measuring cell with silicone oil filling 30 mbar a (0.435 psi a) • Measuring cell with inert filling liquid 30 mbar a (0.435 psi a) Upper measuring limit 100% of max. span (max. 160 bar g (2320 psi g) with oxygen measurement and inert liquid) Output Output signal 4 ... 20 mA Digital PROFIBUS PA or FOUNDATION Fieldbus signal • Lower limit (infinitely adjustable) 3.55 mA, factory preset to 3.84 mA - • Upper limit (infinitely adjustable) 23 mA, factory preset to 20.5 mA or optionally set to 22.0 mA Load • Without HART communication RB ≤ (UH - 10.5 V)/0.023 A in Ω, UH : Power supply in V - • With HART communication RB = 230 ... 500 Ω (SIMATIC PDM) or RB = 230 ... 1100 Ω (HART Communicator) - Physical bus - IEC 61158-2 With polarity reversal protection - Yes Accuracy To EN 60770-1 Reference conditions (All error data refer always refer to the set span) Increasing characteristic, start-of-scale value 0 bar, stainless steel seal diaphragm, silicone oil filling, room temperature 25 °C (77 °F)) r: Span ratio (r = max. span/set span) Error in measurement and fixed-point setting (including hysteresis and repeatability) ≤ 0,075% • Linear characteristic - r ≤ 10 ≤ (0.0029 ⋅ r + 0.071)% - 10 < r ≤ 30 ≤ (0.0045 ⋅ r + 0.071)% - 30 < r ≤ 100 ≤ (0.005 ⋅ r + 0.05)% Long-term drift (temperature change ±30 °C (±54 °F)) ≤ (0.25 ⋅ r)% every 5 years ≤ 0.25% every 5 years • at -10 ... +60 °C (14 ... 140 °F) ≤ (0.08 ⋅ r + 0.1)% (at 700 bar: ≤ (0.1 ⋅ r + 0.2)%) ≤ 0,3% • at -40 ... -10 °C and +60 ... +85 °C (-40 ... +14 °F and 140 ... 185 °F) ≤ (0.1 ⋅ r + 0.15)%/10 K ≤ 0.25%/10 K Measured Value Resolution - 3 ⋅ 10-5 of nominal measuring range Influence of ambient temperature 2/70 Siemens FI 01 · 2009 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for gage pressure SITRANS P, DS III series for gage pressure HART PROFIBUS PA or FOUNDATION Fieldbus Rated operating conditions Degree of protection (to EN 60529) IP65 2 Process temperature • Measuring cell with silicone oil filling -40 ... +100 °C (-40 ... +212 °F) • Measuring cell with inert filling liquid -20 ... +100 °C (-4 ... +212 °F) • In conjunction with dust explosion protection -20 ... +60 °C (-4 ... +140 °F) Ambient conditions • Ambient temperature - Digital indicators -30 ... +85 °C (-22 ... +185 °F) • Storage temperature -50 ... +85 °C (-58 ... +185 °F) • Climatic class - Condensation Permissible • Electromagnetic compatibility - Emitted interference and interference immunity To EN 61326 and NAMUR NE 21 Design Weight (without options) ≈ 1.5 kg (≈ 3.3 lb) Housing material Poor in copper die-cast aluminium, GD-AlSi12 or stainless steel precision casting, mat. No. 1.4408 Wetted parts materials • Connection shank Stainless steel, mat. No. 1.4404/316L or Hastelloy C4, mat. No. 2.4610 • Oval flange Stainless steel, mat. No. 1.4404/316L • Seal diaphragm Stainless steel, mat. No. 1.4404/316L or Hastelloy C276, mat. No. 2.4819 Measuring cell filling Silicone oil or inert filling liquid (max. 160 bar (2320 psi g) with oxygen measurement) Process connection Connection shank G½A to DIN EN 837-1, female thread ½ -14 NPT or oval flange (PN 160 (MWP 2320 psi g)) to DIN 19213 with mounting thread M10 or 7/16-20 UNF to EN 61518 Material of the mounting bracket • Steel Sheet steel, Mat. No. 1.0330, chrome-plated • Stainless steel Stainless steel, Mat. No. 1.4301 (SS304) Supplied through bus Power supply UH Terminal voltage on transmitter 10.5 ... 45 V DC 10.5 ... 30 V DC in intrinsically-safe mode - Separate 24 V power supply necessary - No Bus voltage • Not Ex - 9 ...32 V • With intrinsically-safe operation - 9 ...24 V Current consumption • Basic current (max.) - 12.5 mA • Startup current ≤ basic current - Yes • Max. current in event of fault - 15.5 mA Fault disconnection electronics (FDE) available - Yes Siemens FI 01 · 2009 2/71 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for gage pressure SITRANS P, DS III series for gage pressure HART PROFIBUS PA or FOUNDATION Fieldbus Certificate and approvals 2 Classification according to pressure equipment directive (DRGL 97/23/EC) For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of Article 3, paragraph 3 (sound engineering practice) Explosion protection • Intrinsic safety "i" PTB 99 ATEX 2122 - Identification Ex II 1/2 G EEx ia/ib IIB/IIC T6 - Permissible ambient temperature -40 ... +85 °C (-40 ... +185 °F) temperature class T4; -40 ... +70 °C (-40 ... +158 °F) temperature class T5; -40 ... +60 °C (-40 ... +140 °F) temperature class T6 - Connection To certified intrinsically-safe circuits with maximum values: Ui = 30 V, Ii = 100 mA, Pi = 750 mW; Ri = 300 Ω - Effective internal inductance/capacitance L i = 0.4 mH, Ci = 6 nF • Explosion-proof "d" FISCO supply unit: Uo = 17.5 V, Io = 380 mA, Po = 5.32 W Linear barrier: Uo = 24 V, Io = 250 mA, Po = 1.2 W L i = 7 μH, Ci = 1.1 nF PTB 99 ATEX 1160 - Identification Ex II 1/2 G EEx d IIC T4/T6 - Permissible ambient temperature -40 ... +85 °C (-40 ... +185 °F) temperature class T4; -40 ... +60 °C (-40 ... +140 °F) temperature class T6 - Connection • Dust explosion protection for zone 20 - Identification To circuits with values: UH = 10.5 ... 45 V DC Ex II 1 D IP65 T 120 °C Ex II 1/2 D IP65 T 120 °C - Permissible ambient temperature -40 ... +85 °C (-40 ... +185 °F) - Max.surface temperature 120 °C (248 °F) - Connection To certified intrinsically-safe circuits with maximum values: Ui = 30 V, Ii = 100 mA, Pi = 750 mW, Ri = 300 Ω - Effective internal inductance/capacitance L i = 0.4 mH, Ci = 6 nF • Dust explosion protection for zone 21/22 To circuits with values: UH = 9 ... 32 V DC PTB 01 ATEX 2055 FISCO supply unit: Uo = 17.5 V, Io = 380 mA, Po = 5.32 W Linear barrier: Uo = 24 V, Io = 250 mA, Po = 1.2 W L i = 7 μH, Ci = 1.1 nF PTB 01 ATEX 2055 - Identification Ex II 2 D IP65 T 120 °C - Connection To circuits with values: UH = 10.5 ... 45 V DC; Pmax = 1.2 W To circuits with values: UH = 9 ... 32 V DC; Pmax = 1.2 W TÜV 01 ATEX 1696 X Planned Ex II 3 G EEx nA L IIC T4/T5/T6 - • Type of protection "n" (zone 2) - Identification • Explosion protection to FM - Identification (XP/DIP) or (IS); (NI) • Explosion protection to CSA - Identification (XP/DIP) or (IS) 2/72 Siemens FI 01 · 2009 Certificate of Compliance 3008490 CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; CL I, ZN 0/1 AEx ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III Certificate of Compliance 1153651 CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; Ex ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for gage pressure HART communication HART communication Communication FOUNDATION Fieldbus 230 ... 1100 Ω Protocol HART Version 5.x Software for computer SIMATIC PDM Function blocks 3 function blocks analog input, 1 function block PID • Analog input PROFIBUS PA communication - Adaptation to customer-specif- Yes, linearly rising or falling charic process variables acteristic Simultaneous communication with 4 master class 2 (max.) - Electrical damping T63 , adjust- 0 ... 100 s able The address can be set using - Simulation function Output/input (can be locked within the device with a bridge) - Failure mode Can be parameterized (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively - Square-rooted characteristic for flow measurement Yes Configuration tool or local operation (standard setting address 126) Cyclic data usage • Output byte 5 (one measuring value) or 10 (two measuring values) • Input byte 0, 1, or 2 (register operating mode and reset function for metering) Internal preprocessing Device profile Function blocks PROFIBUS PA Profile for Process Control Devices Version 3.0, Class B • PID • Physical block 1 Resource block 2 Transducer blocks 1 transducer block Pressure with calibration, 1 transducer block LCD • Analog input - Adaptation to customer-specif- Yes, linearly rising or falling charic process variables acteristic - Electrical damping T63 , adjust- 0 ... 100 s able - Simulation function Input /Output - Failure mode Can be parameterized (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively • Register (totalizer) Standard FF function block • Pressure transducer block - Can be calibrated by applying Yes two pressures - Monitoring of sensor limits Yes - Simulation function: Measured Constant value or over parameterpressure value, sensor temper- izable ramp function ature and electronics temperature Can be reset, preset, optional direction of counting, simulation function of register output - Failure mode Can be parameterized (summation with last good value, continuous summation, summation with incorrect value) - Limit monitoring One upper and lower warning limit and one alarm limit respectively • Physical block 1 Transducer blocks 2 • Pressure transducer block - Can be calibrated by applying Yes two pressures - Monitoring of sensor limits Yes - Specification of a container characteristic with Max. 30 nodes - Square-rooted characteristic for flow measurement Yes - Gradual volume suppression and implementation point of square-root extraction Parameterizable - Simulation function for meaConstant value or over parametersured pressure value and sen- izable ramp function sor temperature Siemens FI 01 · 2009 2/73 2 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for gage pressure Selection and Ordering data Order No. Selection and Ordering data SITRANS P pressure transmitters for gage pressure, series DS III HART 7MF 4 0 3 3 - SITRANS P pressure transmitters for gage pressure, series DS III HART Measuring cell filling 2 77777 - 7777 Silicone oil Inert liquid1) Measuring cell cleaning Standard Grease-free } 1 3 Span 0.01 ... 1 bar g 0.04 ... 4 bar g 0.16 ... 16 bar g 0.63 ... 63 bar g 1.6 ... 160 bar g 4.0 ... 400 bar g 7,0 ... 700 bar g (0.15 ... 14.5 psi g) (0.58 ... 58 psi g) (2.32 ... 232 psi g) (9.14 ... 914 psi g) (23.2 ... 2320 psi g) (58.0 ... 5802 psi g) (102.0 ...10153 psi g) } } } } } } } 7MF 4 0 3 3 77777 - 7777 Display • Without indicator • Without visible digital indicator (digital indicator } hidden, setting: mA) • With visible digital indicator, setting: mA B C D E F G J • with customer-specific digital indicator (setting as specified, Order code "Y21" or "Y22" required) Stainless steel Stainless steel Hastelloy Stainless steel Hastelloy Hastelloy Version as diaphragm seal 2) 3) Process connection • Connection shank G½B to EN 837-1 • Female thread ½-14 NPT • Oval flange made of stainless steel - Mounting thread 7/16-20 UNF to EN 61518 - Mounting thread M10 to DIN 19213 - Mounting thread M12 to DIN 19213 • Male thread M20 x 1,5 • Male thread ½-14 NPT Non-wetted parts materials • Housing made of die-cast aluminium • Housing stainless steel precision casting4) } } Version • Standard version • International version, English label inscriptions, } documentation in 5 languages on CD Explosion protection • Without • With ATEX, Type of protection: - "Intrinsic safety (EEx ia)" - "Explosion-proof (EEx d)"5) - "Intrinsic safety and explosion-proof enclosure (EEx ia + EEx d)"6) - "Ex nA/nL (zone 2)" - "Intrinsic safety, explosion-proof enclosure and } dust explosion protection (EEx ia + EEx d + Zone 1D/2D)"6) • With FM + CSA, Type of protection: - "Intrinsic safety and explosion-proof (is + xp)"5) Electrical connection / cable entry • Screwed gland Pg 13.5 (adapter)7) • Screwed gland M20x1.5 • Screwed gland ½-14 NPT • Han 7D plug (plastic housing) incl. mating connector7) • M12 connector (metal)8) Siemens FI 01 · 2009 } 6 7 Power supply units see "SITRANS I power supply units and isolation amplifiers". Factory-mounting of shut-off valves and valve manifolds see page 2/142. Included in delivery of the device: • Brief instructions (Leporello) • CD-ROM with detailed documentation A B C Y 1) 2) 0 1 3) 2 3 4 5 6 } 0 1 }Available ex stock Wetted parts materials Seal diaphragm Process connection 2/74 Order No. 4) 5) 6) 7) 8) 0 3 1 2 A B D P E R NC A B C D F For oxygen application, add Order code E10. When the manufacture’s certificate M (calibration certificate) has to be ordered for transmitters with diaphragm seals, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. Whe the acceptance test certificate 3.1 for transmitters with direct-connected diaphragm seals is ordered, this certificate must also be ordered with the corresponding seals. Not together with Electrical connection „Screwed gland Pg 13.5“ and „Han7D plug“. Without cable gland, with blanking plug With enclosed cable gland EEx ia and blanking plug Not together with type of protection "Explosion-proof" and type of protection "Ex nA". Cannot be used together with the following types of protection: "Explosion-proof" and "Intrinsic safety and explosion-proof" © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for gage pressure Selection and Ordering data Order No. Order No. Selection and Ordering data SITRANS P pressure transmitters for gage pressure SITRANS P pressure transmitters for gage pressure DS III PA (PROFIBUS PA) series 7MF 4 0 3 4 - DS III PA (PROFIBUS PA) series DS III FF series (FOUNDATION Fieldbus) 7MF 4 0 3 5 - DS III FF series (FOUNDATION Fieldbus) 7MF 4 0 3 4 - 77777 - 7777 Measuring cell filling Silicone oil Inert liquid1) Measuring cell cleaning Standard Grease-free Nominal measuring range 1 bar g (14.5 psi g) 4 bar g (58 psi g) 16 bar g (232 psi g) 63 bar g (914 psi g) 160 bar g (2320 psi g) 400 bar g (5802 psi g) 700 bar g (10153 psi g) Display • Without indicator • Without visible digital indicator (digital indicator } hidden, setting: mA) • With visible digital indicator • With customer-specific digital indicator (setting as specified, Order code "Y21" or required) 1 3 B C D E F G J Process connection • Connection shank G½A to EN 837-1 • Female thread ½-14 NPT • Oval flange made of stainless steel - Mounting thread 7/16-20 UNF to EN 61518 - Mounting thread M10 to DIN 19213 - Mounting thread M12 nach DIN 19213 • Male thread M20 x 1,5 • Male thread ½-14 NPT Non-wetted parts materials • Housing made of die-cast aluminium • Housing stainless steel precision casting Version • Standard version • International version, English label inscriptions, documentation in 5 languages on CD Explosion protection • Without • With ATEX, Type of protection: - "Intrinsic safety (EEx ia)" - "Explosion-proof (EEx d)"4) - "Intrinsic safety and explosion-proof enclosure (EEx ia + EEx d)"5) - "Ex nA/nL (zone 2)" - "Intrinsic safety, explosion-proof enclosure and dust explosion protection (EEx ia + EEx d + Zone 1D/2D)"6) (not for DS III FF) • With FM + CSA, Type of protection: - "Intrinsic safety and explosion-proof (is + xp)"5) Electrical connection / cable entry • Screwed gland M20x1.5 • Screwed gland ½-14 NPT • Plug M12 (metal)6) 0 1 6 7 Factory-mounting of shut-off valves and valve manifolds see page 2/142. The device is delivered together with brief instructions (Leporello) and a CD-ROM containing detailed documentation. 1) 2) Wetted parts materials Seal diaphragm Process connection Stainless steel Stainless steel Hastelloy Stainless steel Hastelloy Hastelloy Version as diaphragm seal2) 3) 7MF 4 0 3 5 77777 - 7777 A B C Y 3) 4) 5) 6) 0 1 For oxygen application, add Order code E10. When the manufacture’s certificate M (calibration certificate) has to be ordered for transmitters with diaphragm seals, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. Whe the acceptance test certificate 3.1 for transmitters with direct-connected diaphragm seals is ordered, this certificate must also be ordered with the corresponding seals. Without cable gland, with blanking plug. With enclosed cable gland EEx ia and blanking plug. Cannot be used together with the following types of protection: "Explosion-proof" and "Intrinsic safety and explosion-proof" 2 3 4 5 6 0 3 1 2 A B D P E R NC B C F Siemens FI 01 · 2009 2/75 2 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for gage pressure Selection and Ordering data Order code 2 Selection and Ordering data HART PA Further designs Add "-Z" to Order No. and specify Order code. Pressure transmitter with mounting bracket made of: • Steel • Stainless steel A01 A02 9 9 Plug • Han 7D (metal, gray) • Han 8U (instead of Han 7D) A30 A31 9 9 Cable sockets for M12 connectors (metal) A50 9 9 Rating plate inscription (instead of German) • English • French • Spanish • Italian B11 B12 B13 B14 9 9 9 9 B21 FF Order code HART PA Additional data Add "-Z" to Order No. and specify Order code. FF Measuring range to be set Specify in plain text (max. 5 digits): Y01: ... up to ... mbar, bar, kPa, MPa, psi Y01 9 Measuring point number (TAG No.) Max. 16 characters, specify in plain text: Y15: ........................................... Y15 9 9 9 9 Measuring point text Max. 27 characters, specify in plain text: Y16: ........................................... Y16 9 9 9 9 9 9 9 9 9 9 9 Entry of HART address (TAG) Max. 8 characters, specify in plain text: Y17: ........................................... Y17 9 9 9 9 9 Quality inspection certificate (Factory cali- C11 bration) to IEC 60770-21) 9 9 9 Acceptance test certificate2) To EN 10204-3.1 C12 9 9 9 Factory certificate To EN 10204-2.2 C14 9 9 9 Setting of pressure indication in pressure Y21 units Specify in plain text (standard setting: mA): Y21: mbar, bar, kPa, MPa, psi, ... Note: The following pressure units can be selected: bar, mbar, mm H2O*), inH2O*), ftH2O*), mmHG, inHG, psi, Pa, kPa, MPa, g/cm2, kg/cm2, Torr, ATM oder % *) ref. temperature 20 °C 9 9 C20 9 Y22 + Y01 "PROFIsafe“ certificate and protocol C21 Setting of upper limit of output signal to 22.0 mA D05 9 Manufacturer's declaration acc. to NACE D07 9 9 9 Setting of pressure indication in non-pressure units Specify in plain text: Y22: ..... up to ..... l/min, m3/h, m, USgpm, ... (specification of measuring range in pressure units "Y01" is essential, unit with max. 5 characters) 9 "Functional Safety (SIL)" certificate Type of protection IP68 (not together with 7D/ Han 8U plug, cable gland Pg 13.5) 9 9 9 Preset bus address (possible between 1 and 126) Specify in plain text: Y25: ..................... Y25 D12 Digital indicator alongside the input keys (only together with the devices 7MF4033....0-.A.6 or -.A.7-Z, Y21 or Y22 + Y01) D27 9 9 9 Supplied with oval flange (1 item), PTFE packing and screws in thread of oval flange D37 9 9 9 Use in or on zone 1D/2D (only together with type of protection "Intrinsic safety (EEx ia)") E01 9 9 9 Use on zone 0 (only together with type of protection "Intrinsic safety (EEx ia)") E02 9 9 9 Oxygen application (max. 120 bar g (1740 psi g) at 60°C (140 °F) for oxygen measurement and inert liquid) E10 9 9 9 Explosion-proof "Intrinsic safety" to INMETRO (Brazil) (only for transmitter 7MF4...-.....-.B..) E25 9 9 9 Explosion-proof "Intrinsic safety" to NEPSI (China) (only for transmitter 7MF4...-.....-.B..) E55 9 9 9 Explosion protection "Explosion-proof" to E56 NEPSI (China) (only for transmitter 7MF4...-.....-.D..) 9 9 9 Explosion-proof "Zone 2" to NEPSI (China) E57 (only for transmitter 7MF4...-.....-.E..) 9 9 9 English rating plate Pressure units in inH2O or psi 1) 2) 9 9 9 9 9 9 = available When the manufacture’s certificate M (calibration certificate) has to be ordered for transmitters with diaphragm seals, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. Whe the acceptance test certificate 3.1 for transmitters with direct-connected diaphragm seals is ordered, this certificate must also be ordered with the corresponding seals. 2/76 Siemens FI 01 · 2009 Only "Y01", "Y21", "Y22", "Y25" and "D05" can be factory preset Ordering example Item line: 7MF4033-1EA00-1AA7-Z B line: A01 + Y01 + Y21 C line: Y01: 10 ... 20 bar (145 ... 290 psi) C line: Y21: bar (psi) 9 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for gage pressure ■ Dimensional drawings 55 (2.2) approx 30 (1.2) 4) 100 (3.94) 28 (1.1) 6 20 (0.8) 117 (4.6) ø 80 (3.15) 74 (2.9) 51 (2.0) 3 1) 8 4 120 (4.7) 68 (2.7) 72 (2.8) 1 36,5 (1,44) 1) 5 2 2 171 (6.7) 237 (9.3) 144 (5.67) 50 (1.97) 15 (0.6) 123 (4.8) 7 5) min. 90 (3.6) 1 2 3 4 5 6 7 8 105 (4.1) ø 50 ... 60 (1.97 ... 2.36) Process connection: - ½-14 NPT, - connection shank G½B or - oval flange Blanking plug Electrical connection: - screwed gland M20x1,5 4), - screwed gland ½-14 NPT or - PROFIBUS-Stecker M12 3) 4) Terminal side Electronic side, digital display (longer overall length for cover with window) Protective cover over keys Mounting bracket (option) Screw cover - safety bracket (only for type of protection "Explosion-proof enclosure", not shown in the drawing) 1) 2) 3) 4) Allow approx. 20 mm (0.79 inch) thread length in addition Minimum distance for rotating Not with type of protection "Explosion-proof enclosure" Not with type of protection "FM + CSA" SITRANS P pressure transmitters, DS III HART series for gage pressure, dimensions in mm (inch) Siemens FI 01 · 2009 2/77 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for gage pressure 4) ca. 30 (1.2) 20 (0.8) 117 (4.6) ø 80 (3.15) 100 (3.94) ca. 96 (3.78) 28 (1.1) 6 3 3 1) 8 4 120 (4.7) 68 (2.7) 72 (2.8) 1 36,5 (1,44) 1) 5 2 171 (6.7) 237 (9.3) 51 (2.0) 74 (2.9) 2 55 (2.2) 144 (5.67) 50 (1.97) 15 (0.6) 123 (4.8) 7 5) min. 90 (3.6) 1 2 3 4 5 6 7 8 105 (4.1) ø 50 ... 60 (1.97 ... 2.36) Process connection: - ½-14 NPT, - onnection shankG½B or - oval flange Blanking plug Electrical connection: - screwed gland Pg 13,5 (adapter)2) 3), - screwed gland M20x1,5 3), - screwed gland ½-14 NPT or - Han 7D/ Han 8U 2) 3) plug Terminal side Electronic side, digital display (longer overall length for cover with window) Protective cover over keys Mounting bracket (option) Screw cover - safety bracket (only for type of protection "Explosion-proof enclosure", not shown in the drawing) 1) 2) 3) 4) 5) Allow approx. 20 mm (0.79 inch) thread length to permit unscrewing Not with type of protection "Explosion-proof enclosure" Not with type of protection "FM + CSA" [is + xp]" For Pg 13,5 with adapter approx. 45 mm (1.77 inch) Minimum distance for rotating SITRANS P pressure transmitters, DS III PA and FF series for gage pressure, dimensions in mm (inch) 2/78 Siemens FI 01 · 2009 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for gage and absolute pressure, with front-flush diaphragm ■ Technical specifications SITRANS P, DS III series for gage and absolute pressure, with front-flush diaphragm HART PROFIBUS PA or FOUNDATION Fieldbus Input gage pressure, with front-flush diaphragm 2 Measured variable Gage pressure, flush-mounted Spans (infinitely adjustable) or nominal measuring range and max. permissible test pressure Span Max. perm. test pressure Nominal measuring range Max. perm. test pressure 0.01 ... 1 bar g (0.145 ... 14.5 psi g) 6 bar g (87 psi g) 1 bar g (14.5 psi g) 6 bar g (87 psi g) 0.04 ... 4 bar g (0.58 ... 58 psi g) 10 bar g (145 psi g) 4 bar g (58 psi g) 10 bar g (145 psi g) 0.16 ... 16 bar g (2.23 ... 232 psi g) 32 bar g (464 psi g) 16 bar g (232 psi g) 32 bar g (464 psi g) 0.6 ... 63 bar g (9.14 ... 914 psi g) 100 bar g (1450 psi g) 63 bar g (914 psi g) 100 bar g (1450 psi g) Lower measuring limit -100 mbar a (-1.45 psi a) Upper measuring limit 100% of max. span 100% of nominal measuring range Input absolute pressure, with front-flush diaphragm Measured variable Absolute pressure, flush-mounted Spans (infinitely adjustable) or nominal measuring range and max. permissible test pressure Span Max. perm. test pressure Nominal measuring range Max. perm. test pressure 43 ... 1300 mbar a (0.62 ... 18.9 psi a) 10 bar a (145 psi a) 1300 mbar a (18.9 psi a) 10 bar a (145 psi a) 0,16 ... 5 bar a (2.32 ... 72,5 psi a) 30 bar a (435 psi a) 5 bar a (72,5 psi a) 30 bar a (435 psi a) 1 ... 30 bar a (14.5 ... 435 psi a) 100 bar a (1450 psi a) 30 bar a (435 psi a) 100 bar a (1450 psi a) Depending on the process connection, the span Depending on the process connection, the nomimay differ from these values nal measuring range may differ from these values Lower measuring limit 0 bar a (0 psi a) Upper measuring limit 100% of max. span 100% of nominal measuring range Output signal 4 ... 20 mA Digital PROFIBUS PA or FOUNDATION Fieldbus signal • Lower limit (infinitely adjustable) 3.55 mA, factory preset to 3.84 mA - • Upper limit (infinitely adjustable) 23 mA, factory preset to 20.5 mA or optionally set to 22.0 mA - • Without HART communication RB ≤ (UH - 10.5 V)/0.023 A in Ω, UH : Power supply in V - • With HART communication RB = 230 ... 500 Ω (SIMATIC PDM) or RB = 230 ... 1100 Ω (HART Communicator) - Output Load Physical bus - IEC 61158-2 With polarity reversal protection - Yes Accuracy To EN 60770-1 Reference conditions Increasing characteristic, start-of-scale value 0 bar, stainless steel seal diaphragm, silicone oil fill(All error data refer always refer to the set span) ing, room temperature 25 °C (77 °F)) r: Span ratio (r = max. span/set span) Error in measurement and fixed-point setting (including hysteresis and repeatability) Gage pressure, front-flushed Absolute pressure, front-flushed • Linear characteristic - r ≤ 10 Absolute pressure, front-flushed ≤ 0,075% ≤ 0,2% ≤ (0.0029 ⋅ r + 0.071)% ≤ 0,2% - 10 < r ≤ 30 ≤ (0.0045 ⋅ r + 0.071)% ≤ 0,4% - 30 < r ≤ 100 ≤ (0.005 ⋅ r + 0.05)% Long-term drift (temperature change ±30 °C (±54 °F)) Gage pressure, front-flushed ≤ (0.25 ⋅ r)% every 5 years ≤ 0.25% every 5 years Siemens FI 01 · 2009 2/79 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for gage and absolute pressure, with front-flush diaphragm SITRANS P, DS III series for gage and absolute pressure, with front-flush diaphragm HART PROFIBUS PA or FOUNDATION Fieldbus Influence of ambient temperature 2 • at -10 ... +60 °C (14 ... 140 °F) ≤ (0.1 ⋅ r + 0.2)% • at -40 ... -10 °C and +60 ... +85 °C (-40 ... +14 °F and 140 ... 185 °F) ≤ (0.1 ⋅ r + 0.15)%/10 K ≤ (0,2 ⋅ r + 0,3)%/10 K ≤ (0,2 ⋅ r + 0,3)% Influence of mounting position 0.1 mbar g (0.00145 psi g) per 10° inclination Measured Value Resolution - ≤ 0,3% ≤ 0,5% ≤ 0.25%/10 K ≤ 0,5%/10 K 3 ⋅ 10-5 of nominal measuring range Influence of the medium temperature (only with front-flush diaphragm) • Temperature difference between medium tem- 3 mbar/10 K (0.04 psi/10 K) perature and ambient temperature Rated operating conditions Installation conditions Ambient temperature Observe the temperature class in areas subject to explosion hazard. • Measuring cell with silicone oil -40 ... +85 °C (-40 ... +185 °F) • Measuring cell with Neobee oil (with front-flush -10 ... +85 °C (14 ... +185 °F) diaphragm) • Measuring cell with inert liquid (not with frontflush diaphragm) -20 ... +85 °C (-4 ... +185 °F) • Digital display -30 ... +85 °C (-22 ... +185 °F) • Storage temperature -50 ... +85 °C (-58 ... +185 °F) (with Neobee: -20 ... +85 °C (-4 ... +185 °F) Climatic class Condensation Permissible Degree of protection to EN 60529 IP65, IP68, NEMA X, enclosure cleaning, resistant to lyes, steam to 150° C (302 °F) Electromagnetic compatibility • Emitted interference and interference immunity To EN 61326 and NAMUR NE 21 Medium conditions Process temperature • Measuring cell with silicone oil -40 ... +100 °C (-40 ... +212 °F) • Measuring cell with silicone oil (with front-flush -40 ... +150 °C (-40 ... +302 °F) diaphragm) • Measuring cell with Neobee oil (with front-flush -40 ... +150 °C (-40 ... +302 °F) diaphragm) • Measuring cell with silicone oil, with temperature isolator (only with front-flush diaphragm) -40 ... +200 °C (-40 ... +392 °F) • Measuring cell with inert liquid -20 ... +100 °C (-4 ... +212 °F) • Measuring cell with high temperature oil -10 ... +250 °C (14 ... +482 °F) Design Weight (without options) ≈ 1.5 kg (≈ 3.3 lb) Housing material Poor in copper die-cast aluminium, GD-AlSi12 or stainless steel precision casting, mat. No. 1.4408 Wetted parts materials Stainless steel, mat. No. 1.4404/316L Measuring cell filling Silicone oil or inert filling liquid 2/80 Siemens FI 01 · 2009 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for gage and absolute pressure, with front-flush diaphragm SITRANS P, DS III series for gage and absolute pressure, with front-flush diaphragm HART PROFIBUS PA or FOUNDATION Fieldbus Supplied through bus Power supply UH Terminal voltage on transmitter 10.5 ... 45 V DC 10.5 ... 30 V DC in intrinsically-safe mode - Separate 24 V power supply necessary - No 2 Bus voltage • Not Ex - 9 ...32 V • With intrinsically-safe operation - 9 ...24 V Current consumption • Basic current (max.) - 12.5 mA • Startup current ≤ basic current - Yes • Max. current in event of fault - 15.5 mA Fault disconnection electronics (FDE) available - Yes Certificate and approvals Classification according to pressure equipment For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of Article 3, directive (DRGL 97/23/EC) paragraph 3 (sound engineering practice) Explosion protection • Intrinsic safety "i" PTB 99 ATEX 2122 - Identification Ex II 1/2 G EEx ia/ib IIB/IIC T6 - Permissible ambient temperature -40 ... +85 °C (-40 ... +185 °F) temperature class T4; -40 ... +70 °C (-40 ... +158 °F) temperature class T5; -40 ... +60 °C (-40 ... +140 °F) temperature class T6 - Connection To certified intrinsically-safe circuits with maximum values: Ui = 30 V, Ii = 100 mA, Pi = 750 mW; Ri = 300 Ω FISCO supply unit: Uo = 17.5 V, Io = 380 mA, Po = 5.32 W Linear barrier: Uo = 24 V, Io = 250 mA, Po = 1.2 W L i = 0.4 mH, Ci = 6 nF L i = 7 μH, Ci = 1.1 nF - Effective internal inductance/capacitance • Explosion-proof "d" PTB 99 ATEX 1160 - Identification Ex II 1/2 G EEx d IIC T4/T6 - Permissible ambient temperature -40 ... +85 °C (-40 ... +185 °F) temperature class T4; -40 ... +60 °C (-40 ... +140 °F) temperature class T6 - Connection To circuits with values: UH = 10.5 ... 45 V DC • Dust explosion protection for zone 20 To circuits with values: UH = 9 ... 32 V DC PTB 01 ATEX 2055 - Identification Ex II 1 D IP65 T 120 °C Ex II 1/2 D IP65 T 120 °C - Permissible ambient temperature -40 ... +85 °C (-40 ... +185 °F) - Max.surface temperature 120 °C (248 °F) - Connection To certified intrinsically-safe circuits with maximum values: Ui = 30 V, Ii = 100 mA, Pi = 750 mW, Ri = 300 Ω FISCO supply unit: Uo = 17.5 V, Io = 380 mA, Po = 5.32 W Linear barrier: Uo = 24 V, Io = 250 mA, Po = 1.2 W L i = 0.4 mH, Ci = 6 nF L i = 7 μH, Ci = 1.1 nF - Effective internal inductance/capacitance • Dust explosion protection for zone 21/22 PTB 01 ATEX 2055 - Identification Ex II 2 D IP65 T 120 °C - Connection To circuits with values: UH = 10.5 ... 45 V DC; Pmax = 1.2 W • Type of protection "n" (zone 2) - Identification • Explosion protection to FM - Identification (XP/DIP) or (IS); (NI) • Explosion protection to CSA - Identification (XP/DIP) or (IS) To circuits with values: UH = 9 ... 32 V DC; Pmax = 1.2 W TÜV 01 ATEX 1696 X Planned Ex II 3 G EEx nA L IIC T4/T5/T6 - Certificate of Compliance 3008490 CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; CL I, ZN 0/1 AEx ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III Certificate of Compliance 1153651 CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; Ex ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III Hygiene version In the case of SITRANS P DSIII with 7MF413x front-flush diaphragm, selected connections comply with the requirements of EHEDG. Siemens FI 01 · 2009 2/81 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for gage and absolute pressure, with front-flush diaphragm HART communication HART communication 2 Communication FOUNDATION Fieldbus 230 ... 1100 Ω Protocol HART Version 5.x Software for computer SIMATIC PDM Function blocks 3 function blocks analog input, 1 function block PID • Analog input PROFIBUS PA communication - Adaptation to customer-specif- Yes, linearly rising or falling charic process variables acteristic Simultaneous communication with 4 master class 2 (max.) - Electrical damping T63 , adjust- 0 ... 100 s able The address can be set using - Simulation function Output/input (can be locked within the device with a bridge) - Failure mode Can be parameterized (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively - Square-rooted characteristic for flow measurement Yes Configuration tool or local operation (standard setting address 126) Cyclic data usage • Output byte 5 (one measuring value) or 10 (two measuring values) • Input byte 0, 1, or 2 (register operating mode and reset function for metering) Internal preprocessing Device profile Function blocks PROFIBUS PA Profile for Process Control Devices Version 3.0, Class B • PID • Physical block 1 Resource block 2 Transducer blocks 1 transducer block Pressure with calibration, 1 transducer block LCD • Analog input - Adaptation to customer-specif- Yes, linearly rising or falling charic process variables acteristic - Electrical damping T63 , adjust- 0 ... 100 s able - Simulation function Input /Output - Failure mode Can be parameterized (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively • Register (totalizer) Can be reset, preset, optional direction of counting, simulation function of register output - Failure mode Can be parameterized (summation with last good value, continuous summation, summation with incorrect value) - Limit monitoring One upper and lower warning limit and one alarm limit respectively • Physical block 1 Transducer blocks 2 • Pressure transducer block - Can be calibrated by applying Yes two pressures - Monitoring of sensor limits Yes - Specification of a container characteristic with Max. 30 nodes - Square-rooted characteristic for flow measurement Yes - Gradual volume suppression and implementation point of square-root extraction Parameterizable - Simulation function for meaConstant value or over parametersured pressure value and sen- izable ramp function sor temperature 2/82 Siemens FI 01 · 2009 Standard FF function block • Pressure transducer block - Can be calibrated by applying Yes two pressures - Monitoring of sensor limits Yes - Simulation function: Measured Constant value or over parameterpressure value, sensor temper- izable ramp function ature and electronics temperature © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for gage and absolute pressure, with front-flush diaphragm Selection and Ordering data Order No. Measuring cell filling Silicone oil Inert liquid FDA compliant fill fluid • Neobee oil Measuring cell cleaning Standard Grease-free 1 3 Standard 4 B C D E 13 ... 1300 mbar a2) 0.05 ... 5 bar a2) 3 ... 30 bar a2) (0.19 ... 18.9 psi a)2) (0.7 ... 72.5 psi a)2) (43.5 ... 435 psi a)2) S T U Non-wetted parts materials • Housing made of die-cast aluminium • Housing stainless steel precision casting Version • Standard version • International version, English label inscriptions, documentation in 5 languages on CD Explosion protection • Without • With ATEX, Type of protection: - "Intrinsic safety (EEx ia)" - "Explosion-proof (EEx d)"3) - "Intrinsic safety, explosion-proof enclosure and dust explosion protection (EEx ia + EEx d + Zone 1D/2D)"4) • With FM + CSA, Type of protection: - "Intrinsic safety and explosion-proof (is + xp)"3) (available soon) Electrical connection / cable entry • Inner thread M20x1.5 • Female thread ½-14 NPT • M12 connectors (metal)5) F) 7 M F 4 1 3 4 - DS III FF series (FOUNDATION Fieldbus) F) 7 M F 4 1 3 5 - Silicone oil Inert liquid FDA compliant fill fluid • Neobee oil Wetted parts materials Seal diaphragm Connection shank Stainless steel DS III PA series (PROFIBUS PA) Measuring cell filling (0.15 ... 14.5 psi g)1) (0.58 ... 58 psi g) (2.32 ... 232 psi g) (9.14 ... 914 psi g) Process connection • Flange version with Order code M.., N.., R.. or Q.. SITRANS P pressure transmitters for gage pressure, front-flush membrane 77777 - 7777 Span 0.01 ... 1 bar g1) 0.04 ... 4 bar g 0.16 ... 16 bar g 0.63 ... 63 bar g Stainless steel Order No. Selection and Ordering data SITRANS P pressure transmitters for gage and F) 7 M F 4 1 3 3 absolute pressure, front-flush membrane, 77777 - 7777 series DS III HART A Measuring cell cleaning Standard Grease-free 1 3 Standard 4 Nominal measuring range 1 bar g1) (14.5 psi g)1) 4 bar g (58 psi g) 16 bar g (232 psi g) 63 bar g (914 psi g) B C D E 1300 mbar a2) 5 bar a2) 30 bar a2) S T U (18.9 psi a)2) (72.5 psi a)2) (435 psi a)2) Wetted parts materials Seal diaphragm Connection shank 7 Stainless steel Stainless steel Process connection • Flange version with Order code M.., N.., R.. or Q.. 0 3 Version • Standard version • International version, English label inscriptions, documentation in 5 languages on CD A B D R Explosion protection • Without • With ATEX, Type of protection: - "Intrinsic safety (EEx ia)" - "Explosion-proof (EEx d)"3) - "Intrinsic safety, explosion-proof enclosure and dust explosion protection (EEx ia + EEx d + Zone 1D/2D)"4) • With FM + CSA, Type of protection: - "Intrinsic safety and explosion-proof (is + xp)"3) (available soon) NC B C F 0 1 Electrical connection / cable entry • Screwed gland M20x1.5 • Screwed gland ½-14 NPT • M12 connectors (metal) 5) Power supply units see "SITRANS I power supply units and isolation amplifiers". Included in delivery of the device: • Brief instructions (Leporello) • CD-ROM with detailed documentation Included in delivery of the device: • Brief instructions (Leporello) • CD-ROM with detailed documentation 1) 1) 4) 5) 6 7 Only with "Standard" process connection Not with temperature decoupler P00 and P10, not for process connections R02, R04, R10 and R11, and can only be ordered in conjunction with silicone oil. Without cable gland, with blanking plug. With enclosed cable gland EEx ia and blanking plug. Cannot be used together with the following types of protection: "Explosion-proof" and "Intrinsic safety and explosion-proof" F) Subject to export regulations AL: 9I999, ECCN: N. 2) 3) 4) 5) 0 3 1 2 A B D R NC B C F Display • Without indicator • Without visible digital indicator (digital indicator } hidden, setting: mA) • With visible digital display • With customer-specific digital display (setting as specified, Order code "Y21" or required) 3) 7 Non-wetted parts materials • Housing made of die-cast aluminium • Housing stainless steel precision casting 1 2 Display • Without indicator • Without visible digital indicator (digital indicator } hidden, setting: mA) • With visible digital indication, setting: mA • With customer-specific digital indication (setting as specified, Order code "Y21" or "Y22" required) 2) A 0 1 6 7 Only with "Standard" process connection Not with temperature decoupler P00 and P10, not for process connections R02, R04, R10 and R11, and can only be ordered in conjunction with silicone oil. Without cable gland, with blanking plug. With enclosed cable gland EEx ia and blanking plug. Cannot be used together with the following types of protection: "Explosion-proof" and "Intrinsic safety and explosion-proof" F) Subject to export regulations AL: 9I999, ECCN: N. Siemens FI 01 · 2009 2/83 2 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for gage and absolute pressure, with front-flush diaphragm Selection and Ordering data Order code Selection and Ordering data HART PA Further designs FF Add "-Z" to Order No. and specify Order code. 2 Cable sockets for M12 connectors (metal) A50 9 9 9 • English • French • Spanish • Italian B11 B12 B13 B14 9 9 9 9 9 9 9 9 9 9 9 9 English rating plate Pressure units in inH2O or psi B21 9 9 9 Quality inspection certificate (Factory cali- C11 bration) to IEC 60770-2 9 9 Temperature decoupler up to 200 °C4) for version with front-flush diaphragm P00 9 9 9 P10 Temperature decoupler up to 250 °C Measuring cell filling: High-temperature oil, only in conjunction with measuring cell filling silicone oil 9 9 9 Q53 Q54 9 9 9 9 9 9 9 Sanitary process connection to DRD • 65 mm, PN 40 M32 9 9 9 SMS socket with union nut • 2“ • 2½“ • 3“ M67 M68 M69 9 9 9 9 9 9 9 9 9 SMS threaded socket • 2“ • 2½“ • 3“ M73 M74 M75 9 9 9 9 9 9 9 9 9 IDF socket with union nut ISO 2853 • 2“ • 2½“ • 3“ M82 M83 M84 9 9 9 9 9 9 9 9 9 IDF threaded socket ISO 2853 • 2“ • 2½“ • 3“ M92 M93 M94 9 9 9 9 9 9 9 9 9 Q05 Q06 Q07 Q08 Q13 Q14 Q15 Q16 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 Q23 Q24 Q25 Q26 Q31 Q32 Q33 Q34 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 Q39 Q40 Q41 Q42 Q48 Q49 Q50 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 C12 9 9 9 Factory certificate To EN 10204-2.2 C14 9 9 9 "PROFIsafe" certificate and protocol C21 Flanges to EN 1092-1 • DN 25, PN 401) • DN 25, PN 1001) • DN 40, PN 40 • DN 40, PN 100 • DN 50, PN 16 • DN 50, PN 40 • DN 80, PN 16 • DN 80, PN 40 M11 M21 M13 M23 M04 M14 M06 M16 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 Flanges to ASME B16.5 • Stainless steel flange 1" class 1501) • Stainless steel flange 1½" class 150 • Stainless steel flange 2" class 150 • Stainless steel flange 3" class 150 • Stainless steel flange 4" class 150 • Stainless steel flange 1" class 3001) • Stainless steel flange 1½" class 300 • Stainless steel flange 2" class 300 • Stainless steel flange 3" class 300 • Stainless steel flange 4" class 300 M40 M41 M42 M43 M44 M45 M46 M47 M48 M49 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 Threaded connection acc. to DIN 3852-2, Form A • G ¾“, flush-mounted2) • G 1“, flush-mounted2) • G 2“, flush-mounted2) R01 R02 R04 9 9 9 9 9 9 9 9 9 Tank connection3) Sealing is included in delivery • TG 52/50, PN 40 • TG 52/150, PN 40 R10 R11 9 9 9 9 9 9 Sanitary process connection according DIN 11851 (Dairy connection) • DN 50, PN 25 • DN 80, PN 25 N04 N06 9 9 9 9 9 9 Tri-Clamp connection according DIN 32676/ISO 2852 • DN 50/2“, PN 16 • DN 65/3“, PN 10 N14 N15 9 9 9 9 9 9 N28 9 9 9 Siemens FI 01 · 2009 FF Bio-Control (Neumo) sanitary connection certified to EHEDG • DN 50, PN 16 • DN 65, PN 16 Acceptance test certificate To EN 10204-3.1 2/84 HART PA Add "-Z" to Order No. and specify Order code. Rating plate inscription (instead of German) Varivent connection certified to EHEDG • Type N = 68 for Varivent housing DN 40 ... 125 and 1½" ... 6", PN 40 Order code Further designs 9 Sanitary process connection to NEUMO Bio-Connect screw connection certified to EHEDG • DN 50, PN 16 • DN 65, PN 16 • DN 80, PN 16 • DN 100, PN 16 • DN 2“, PN 16 • DN 2½“, PN 16 • DN 3“, PN 16 • DN 4“, PN 16 Sanitary process connection to NEUMO Bio-Connect flange connection certified to EHEDG • DN 50, PN 16 • DN 65, PN 16 • DN 80, PN 16 • DN 100, PN 16 • DN 2“, PN 16 • DN 2½“, PN 16 • DN 3“, PN 16 • DN 4“, PN 16 Sanitary process connection to NEUMO Bio-Connect clamp connection certified to EHEDG • DN 50, PN 16 • DN 65, PN 10 • DN 80, PN 10 • DN 100, PN 10 • DN 2½“, PN 16 • DN 3“, PN 10 • DN 4“, PN 10 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for gage and absolute pressure, with front-flush diaphragm Selection and Ordering data Order code Order code Selection and Ordering data HART PA Further designs FF HART PA Additional data FF Add "-Z" to Order No. and specify Order code. Add "-Z" to Order No. and specify Order code. Sanitary process connection to NEUMO Connect S flange connection certified to EHEDG • DN 50, PN 16 • DN 65, PN 10 • DN 80, PN 10 • DN 100, PN 10 • DN 2“, PN 16 • DN 2½“, PN 10 • DN 3“, PN 10 • DN 4“, PN 10 Y01 9 Q63 Q64 Q65 Q66 Q72 Q73 Q74 Q75 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 Measuring range to be set Specify in plain text (max. 5 digits): Y01: ... up to ... mbar, bar, kPa, MPa, psi Measuring point number (TAG No.) Max. 16 characters, specify in plain text: Y15: ........................................... Y15 9 9 9 Measuring point text Max. 27 characters, specify in plain text: Y16: ........................................... Y16 9 9 9 9 9 N33 N34 N35 N36 9 9 9 9 9 9 9 9 9 9 9 9 Aseptic flange with notch to DIN 11864-2 Form A • DN 50, PN 16 • DN 65, PN 16 • DN 80, PN 16 • DN 100, PN 16 Setting of pressure indicator in pressure Y21 units Specify in plain text (standard setting: mA): Y21: mbar, bar, kPa, MPa, psi, ... Note: The following pressure units can be selected: bar, mbar, mm H2O*), inH2O*), ftH2O*), mmHG, inHG, psi, Pa, kPa, MPa, g/cm2, kg/cm2, Torr, ATM oder % *) ref. temperature 20 °C 9 Aseptic threaded socket to DIN 11864-1 Form A • DN 50, PN 25 • DN 65, PN 25 • DN 80, PN 25 • DN 100, PN 25 N43 N44 N45 N46 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 Aseptic flange with groove to DIN 11864-2 Form A • DN 50, PN 16 N43 + P11 • DN 65, PN 16 N44 + P11 • DN 80, PN 16 N45 + P11 • DN 100, PN 16 N46 + P11 Aseptic clamp with groove to DIN 11864-3 Form A • DN 50, PN 25 • DN 65, PN 25 • DN 80, PN 16 • DN 100, PN 16 1) 2) 3) 4) N53 N54 N55 N56 Preset bus address (possible between 1 and 126) Specify in plain text: Y25: ..................... Y25 2 9 Only "Y01" and "Y21" can be factory preset 9 = available Ordering example Item line: 7MF4133-1DB20-1AB7-Z B line: A22 + Y01 + Y21 C line: Y01: 1 ... 10 bar (14.5 ... 145 psi) C line: Y21: bar (psi) Special Viton seal included in delivery. Lower measuring limit -100 mbar g (1.45 psi g). The weldable socket can be ordered under accessories The maximum temperatures of the medium depend on the respective cell fillings. Siemens FI 01 · 2009 2/85 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for gage and absolute pressure, with front-flush diaphragm ■ Dimensional drawings DSSUR[ 6SDFHIRUURWDWLRQ RIKRXVLQJ 90 (3.6) + DSSUR[ 2 3URFHVV FRQQHFWLRQ VHH IODQJH WDEOHV %ODQNLQJ SOXJ (OHFWULFDO FRQQHFWLRQ VFUHZHGJODQG0[ VFUHZHGJODQG137 7HUPLQDO VLGH (OHFWURQLFV VLGH GLJLWDO GLVSOD\ ORQJHU RYHUDOO OHQJWK IRU FRYHU WKZLQGRZ ZL 3URWHFWLYH FRYHU RYHU NH\V 6FUHZ FRYHU VDIHW\ EUDFNHW RQO\ IRU H[SORVLRQSURRI HQFORVXUH QRWVKRZQLQWKHGUDZLQJ $OORZ DSSUR[ PP LQFK WKUHDGOHQJWKLQDGGLWLRQ PP LQFK IRU PLQLPXP GLVWDQFH WRSHUPLWURWDWLRQZLWKLQGLFDWRU SITRANS P pressure transmitters, DS III series for gage pressure, with front-flush diaphragm, dimensions in mm (inch) The diagram shows a SITRANS P DS III with an example of a flange. In this drawing the height is subdivided into H1 and H2. NuG and pharmaceutical connections Connections to DIN H1 = Height of the SITRANS DS III up to a defined cross-section DIN 11851 (Dairy connection) DN PN ∅D H2 Only the height H2 is indicated in the dimensions of the flanges. 50 25 92 mm (3.6“) 80 25 127 mm (5.0“) Approx. 52 mm (2“) + H2 = Height of the flange up to this defined cross-section Flanges to EN and ASME ' Flanges to EN Tri-Clamp according DIN 32676 EN 1092-1 + 25 25 40 40 50 50 80 80 ' PN 40 100 40 100 16 40 16 40 ∅D 115 mm (4.5“) 140 mm (5.5“) 150 mm (5.9“) 170 mm (6.7“) 165 mm (6.5“) 165 mm (6.5“) 200 mm (7.9“) 200 mm (7.9“) H2 DN PN ∅D H2 Approx. 52 mm (2“) 50 16 64 mm (2.5“) 65 16 91 mm (3.6“) Approx. 52 mm (2“) + DN ' Other connections Varivent connection PN ∅D H2 40 ... 125 40 84 mm (3.3“) Approx. 52 mm (2“) + Flanges to ASME DN ' 2/86 DN class ∅D 1“ 1“ 1½“ 1½“ 2“ 2“ 3“ 3“ 4“ 4“ 150 300 150 300 150 300 150 300 150 300 110 mm (4.3“) Approx. 125 mm (4.9“) 52 mm (2“) 130 mm (5.1“) 155 mm (6.1“) 150 mm (5.9“) 165 mm (6.5“) 190 mm (7.5“) 210 mm (8.1“) 230 mm (9.1“) 255 mm (10.0“) Siemens FI 01 · 2009 H2 ' Bio-Control connection + + ASME B16.5 ' DN PN ∅D H2 50 16 90 mm (3.5“) 65 16 120 mm (4.7“) Approx. 52 mm (2“) © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for gage and absolute pressure, with front-flush diaphragm Thread connection G¾“, G1“ and G2“ to DIN 3852 DN PN ∅D H2 DN PN ∅D H2 50 40 105 mm (4.1“) Approx. 52 mm (2“) ¾“ 63 37 mm (1.5“) Approx. 45 mm (1.8“) 1“ 63 48 mm (1.9“) Approx. 47 mm (1.9“) 2“ 63 78 mm (3.1“) Approx. 52 mm (2“) + + Sanitary process connection to DRD ' ' PN ∅D H2 50 16 82 mm (3.2“) 65 16 105 mm (4.1“) Approx. 52 mm (2“) 80 16 115 mm (4.5“) 100 16 145 mm (5.7“) 2“ 16 82 mm (3.2“) 2½“ 16 105 mm (4.1“) 3“ 16 105 mm (4.1“) 4“ 16 145 mm (5.7“) + DN PN ∅D H2 50 16 110 mm (4.3“) 65 16 140 mm (5.5“) Approx. 52 mm (2“) 80 16 150 mm (5.9“) 100 16 175 mm (6.9“) ∅D H2 40 63 mm (2.5“) Approx. 63 mm (2.5“) 25 40 63 mm (2.5“) Approx. 170 mm (6.7“) DN PN ∅D H2 2“ 25 84 mm (3.3“) 2½“ 25 100 mm (3.9“) Approx. 52 mm (2.1“) 3“ 25 114 mm (4.5“) 2“ 16 100 mm (3.9“) 2½“ 16 110 mm (4.3“) 3“ 16 140 mm (5.5“) DN PN ∅D H2 4“ 16 175 mm (6.9“) Approx. 52 mm (2.1“) ' + SMS threaded socket 2“ 25 70 x 1/6 mm 2½“ 25 85 x 1/6 mm 3“ 25 98 x 1/6 mm DN PN ∅D H2 2“ 25 77 mm (3“) 2½“ 25 91 mm (3.6“) Approx. 52 mm (2.1“) 3“ 25 106 mm (4.2“) DN PN ∅D 2“ 25 64 mm (2.5“) 2½“ 25 3“ 25 ' DN PN ∅D 50 16 65 10 77,4 mm (3.0“) Approx. 52 mm (2“) 90,9 mm (3.6“) 80 10 106 mm (4.2“) 100 10 119 mm (4.7“) 2“ 16 64 mm (2.5“) 2½“ 16 77,4 mm (3.0“) 3“ 10 90,9 mm (3.6“) 4“ 10 119 mm (4.7“) H2 IDF socket with union nut + + PN 25 SMS socket with union nut Sanitary connection to NEUMO Bio-Connect clamp connection ' DN ' Sanitary connection to NEUMO Bio-Connect flange connection ' Tank connection TG52/50 and TG52/150 + ' DN + + Sanitary process screw connection to NEUMO Bio-Connect ' IDF threaded socket + DN ' PN ∅D H2 Approx. 52 mm (2“) 50 16 125 mm (4.9“) 65 10 145 mm (5.7“) 80 10 155 mm (6.1“) 100 10 180 mm (7.1“) 2“ 16 125 mm (4.9“) 2½“ 10 135 mm (5.3“) 3“ 10 145 mm (5.7“) 4“ 10 180 mm (7.1“) + Sanitary connection to NEUMO Bio-Connect S flange connection H2 Approx. 52 mm 77.5 mm (3.1“) (2.1“) 91 mm (3.6“) ' Siemens FI 01 · 2009 2/87 2 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for gage and absolute pressure, with front-flush diaphragm DN PN ∅D H2 50 25 78 x 1/6“ 65 25 95 x 1/6“ Approx. 52 mm (2.1“) 80 25 110 x ¼“ 100 25 130 x ¼“ ' Aseptic flange with notch to DIN 11864-2 Form A + DN ' PN ∅D H2 Approx. 52 mm (2.1“) 50 16 94 65 16 113 80 16 133 100 16 159 + Aseptic flange with groove to DIN 11864-2 Form A ' DN PN ∅D H2 50 16 94 65 16 113 Approx. 52 mm (2.1“) 80 16 133 100 16 159 Aseptic clamp with groove to DIN 11864-3 Form A DN + 2 + Aseptic threaded socket to DIN 11864-1 Form A PN H2 Approx. 52 mm (2.1“) 50 25 77,5 65 25 91 80 16 106 100 16 130 ' 2/88 ∅D Siemens FI 01 · 2009 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for absolute pressure (from gage pressure series) ■ Technical specifications SITRANS P, DS III series for absolute pressure (from the gage pressure series) HART PROFIBUS PA or FOUNDATION Fieldbus Input 2 Measured variable Absolute pressure Spans (infinitely adjustable) or nominal measuring range and max. permissible test pressure Span Max. perm. test pressure Nominal measuring range Max. perm. test pressure 8.3 ... 250 mbar a (0.12 ... 3.6 psi a) 6 bar a (87 psi a) 250 mbar a (3.6 psi a) 6 bar a (87 psi a) 43 ... 1300 mbar a (0.62 ... 18.9 psi a) 10 bar a (145 psi a) 1300 mbar a (18.9 psi a) 10 bar a (145 psi a) 160 ... 5000 mbar a (2.32 ... 72.5 psi a) 30 bar a (435 psi a) 5 bar a (72.5 psi a) 30 bar a (435 psi a) 1 ... 30 bar a (14.5 ... 435 psi a) 100 bar a (1450 psi a) 30 bar a (435 psi a) 100 bar a (1450 psi a) Lower measuring limit • Measuring cell with silicone oil filling 0 mbar a (0 psi a) Upper measuring limit 100% of max. span Output Output signal 4 ... 20 mA Digital PROFIBUS PA or FOUNDATION Fieldbus signal • Lower limit (infinitely adjustable) 3.55 mA, factory preset to 3.84 mA - • Upper limit (infinitely adjustable) 23 mA, factory preset to 20.5 mA or optionally set to 22.0 mA Load • Without HART communication RB ≤ (UH - 10.5 V)/0.023 A in Ω, UH : Power supply in V - • With HART communication RB = 230 ... 500 Ω (SIMATIC PDM) or RB = 230 ... 1100 Ω (HART Communicator) - Physical bus - IEC 61158-2 With polarity reversal protection - Yes Accuracy To EN 60770-1 Reference conditions (All error data refer always refer to the set span) Increasing characteristic, start-of-scale value 0 bar, stainless steel seal diaphragm, silicone oil filling, room temperature 25 °C (77 °F)) r: Span ratio (r = max. span / set span) Error in measurement and fixed-point setting (including hysteresis and repeatability) ≤ 0.1% • Linear characteristic - r ≤ 10 ≤ 0.1% - 10 < r ≤ 30 ≤ 0.2% Long-term drift (temperature change ±30 °C (±54 °F)) ≤ (0.1 ⋅ r)%/year ≤ 0.1%/year • at -10 ... +60 °C (14 ... 140 °F) ≤ (0.1 ⋅ r +0.2)% ≤ 0,3% • at -40 ... -10 °C and +60 ... +85 °C (-40 ... +14 °F and 140 ... 185 °F) ≤ (0.1 ⋅ r + 0.15)%/10 K ≤ 0.25%/10 K Measured Value Resolution - 3 ⋅ 10-5 of nominal measuring range Influence of ambient temperature Siemens FI 01 · 2009 2/89 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for absolute pressure (from gage pressure series) SITRANS P, DS III series for absolute pressure (from the gage pressure series) HART PROFIBUS PA or FOUNDATION Fieldbus Rated operating conditions 2 Degree of protection (to EN 60529) IP65 Process temperature • Measuring cell with silicone oil filling -40 ... +100 °C (-40 ... +212 °F) • Measuring cell with inert filling liquid -20 ... +100 °C (-4 ... +212 °F) • In conjunction with dust explosion protection -20 ... +60 °C (-4 ... +140 °F) Ambient conditions • Ambient temperature - Digital indicators -30 ... +85 °C (-22 ... +185 °F) • Storage temperature -50 ... +85 °C (-58 ... +185 °F) • Climatic class - Condensation Permissible • Electromagnetic compatibility - Emitted interference and interference immunity To EN 61326 and NAMUR NE 21 Design Weight (without options) ≈ 1.5 kg (≈ 3.3 lb) Housing material Poor in copper die-cast aluminium, GD-AlSi12 or stainless steel precision casting, mat. No. 1.4408 Wetted parts materials • Connection shank Stainless steel, mat. No. 1.4404/316L or Hastelloy C4, mat. No. 2.4610 • Oval flange Stainless steel, mat. No. 1.4404/316L • Seal diaphragm Stainless steel, mat. No. 1.4404/316L or Hastelloy C276, mat. No. 2.4819 Measuring cell filling Silicone oil or inert filling liquid (max. 160 bar a (2320 psi a) with oxygen measurement) Process connection Connection shank G½A to DIN EN 837-1, female thread ½ -14 NPT or oval flange (PN 160 (MWP 2320 psi a)) to DIN 19213 with mounting thread M10 or 7/16-20 UNF to EN 61518 Material of the mounting bracket • Steel Sheet steel, Mat. No. 1.0330, chrome-plated • Stainless steel Stainless steel, Mat. No. 1.4301 (SS304) Supplied through bus Power supply UH Terminal voltage on transmitter 10.5 ... 45 V DC 10.5 ... 30 V DC in intrinsically-safe mode - Separate 24 V power supply necessary - No Bus voltage • Not Ex - 9 ... 32 V • With intrinsically-safe operation - 9 ... 24 V Current consumption • Basic current (max.) - 12.5 mA • Startup current ≤ basic current - Yes • Max. current in event of fault - 15.5 mA Fault disconnection electronics (FDE) available - Yes 2/90 Siemens FI 01 · 2009 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for absolute pressure (from gage pressure series) SITRANS P, DS III series for absolute pressure (from the gage pressure series) HART PROFIBUS PA or FOUNDATION Fieldbus Certificate and approvals Classification according to pressure equipment directive (DRGL 97/23/EC) For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of Article 3, paragraph 3 (sound engineering practice) Explosion protection • Intrinsic safety "i" PTB 99 ATEX 2122 - Identification Ex II 1/2 G EEx ia/ib IIB/IIC T6 - Permissible ambient temperature -40 ... +85 °C (-40 ... +185 °F) temperature class T4; -40 ... +70 °C (-40 ... +158 °F) temperature class T5; -40 ... +60 °C (-40 ... +140 °F) temperature class T6 - Connection To certified intrinsically-safe circuits with maximum values: Ui = 30 V, Ii = 100 mA, Pi = 750 mW; Ri = 300 Ω - Effective internal inductance/capacitance L i = 0.4 mH, Ci = 6 nF • Explosion-proof "d" FISCO supply unit: Uo = 17.5 V, Io = 380 mA, Po = 5.32 W Linear barrier: Uo = 24 V, Io = 250 mA, Po = 1.2 W L i = 7 μH, Ci = 1.1 nF PTB 99 ATEX 1160 - Identification Ex II 1/2 G EEx d IIC T4/T6 - Permissible ambient temperature -40 ... +85 °C (-40 ... +185 °F) temperature class T4; -40 ... +60 °C (-40 ... +140 °F) temperature class T6 - Connection • Dust explosion protection for zone 20 - Identification To circuits with values: UH = 10.5 ... 45 V DC Ex II 1 D IP65 T 120 °C Ex II 1/2 D IP65 T 120 °C - Permissible ambient temperature -40 ... +85 °C (-40 ... +185 °F) - Max.surface temperature 120 °C (248 °F) - Connection To certified intrinsically-safe circuits with maximum values: Ui = 30 V, Ii = 100 mA, Pi = 750 mW, Ri = 300 Ω - Effective internal inductance/capacitance L i = 0.4 mH, Ci = 6 nF • Dust explosion protection for zone 21/22 To circuits with values: UH = 9 ... 32 V DC PTB 01 ATEX 2055 FISCO supply unit: Uo = 17.5 V, Io = 380 mA, Po = 5.32 W Linear barrier: Uo = 24 V, Io = 250 mA, Po = 1.2 W L i = 7 μH, Ci = 1.1 nF PTB 01 ATEX 2055 - Identification Ex II 2 D IP65 T 120 °C - Connection To circuits with values: UH = 10.5 ... 45 V DC; Pmax = 1.2 W To circuits with values: UH = 9 ... 32 V DC; Pmax = 1.2 W TÜV 01 ATEX 1696 X Planned Ex II 3 G EEx nA L IIC T4/T5/T6 - • Type of protection "n" (zone 2) - Identification • Explosion protection to FM - Identification (XP/DIP) or (IS); (NI) • Explosion protection to CSA - Identification (XP/DIP) or (IS) Certificate of Compliance 3008490 CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; CL I, ZN 0/1 AEx ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III Certificate of Compliance 1153651 CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; Ex ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III Siemens FI 01 · 2009 2/91 2 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for absolute pressure (from gage pressure series) HART communication HART communication 2 Communication FOUNDATION Fieldbus 230 ... 1100 Ω Protocol HART Version 5.x Software for computer SIMATIC PDM Function blocks 3 function blocks analog input, 1 function block PID • Analog input PROFIBUS PA communication - Adaptation to customer-specif- Yes, linearly rising or falling charic process variables acteristic Simultaneous communication with 4 master class 2 (max.) - Electrical damping T63 , adjust- 0 ... 100 s able The address can be set using - Simulation function Output/input (can be locked within the device with a bridge) - Failure mode Can be parameterized (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively - Square-rooted characteristic for flow measurement Yes Configuration tool or local operation (standard setting address 126) Cyclic data usage • Output byte 5 (one measuring value) or 10 (two measuring values) • Input byte 0, 1, or 2 (register operating mode and reset function for metering) Internal preprocessing Device profile Function blocks PROFIBUS PA Profile for Process Control Devices Version 3.0, Class B • PID • Physical block 1 Resource block 2 Transducer blocks 1 transducer block Pressure with calibration, 1 transducer block LCD • Analog input - Adaptation to customer-specif- Yes, linearly rising or falling charic process variables acteristic - Electrical damping T63 , adjust- 0 ... 100 s able - Simulation function Input /Output - Failure mode Can be parameterized (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively • Register (totalizer) Can be reset, preset, optional direction of counting, simulation function of register output - Failure mode Can be parameterized (summation with last good value, continuous summation, summation with incorrect value) - Limit monitoring One upper and lower warning limit and one alarm limit respectively • Physical block 1 Transducer blocks 2 • Pressure transducer block - Can be calibrated by applying Yes two pressures - Monitoring of sensor limits Yes - Specification of a container characteristic with Max. 30 nodes - Square-rooted characteristic for flow measurement Yes - Gradual volume suppression and implementation point of square-root extraction Parameterizable - Simulation function for meaConstant value or over parametersured pressure value and sen- izable ramp function sor temperature 2/92 Siemens FI 01 · 2009 Standard FF function block • Pressure transducer block - Can be calibrated by applying Yes two pressures - Monitoring of sensor limits Yes - Simulation function: Measured Constant value or over parameterpressure value, sensor temper- izable ramp function ature and electronics temperature © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for absolute pressure (from gage pressure series) Selection and Ordering data Order No. Order No. Selection and Ordering data SITRANS P pressure transmitters for absolute F) 7 M F 4 2 3 3 pressure, from the pressure series DS III HART 77777 - 7777 SITRANS P pressure transmitters for absolute F) 7 M F 4 2 3 3 pressure, from the pressure series DS III HART 77777 - 7777 Measuring cell filling Display • Without indicator • Without visible digital indicator (digital indicator } hidden, setting: mA) • With visible digital indicator • With customer-specific digital indicator (setting as specified, Order code "Y21" or required) Silicone oil Inert liquid1) Measuring cell cleaning Standard Grease-free Span 8.3 ... 250 mbar a 43 ... 1300 mbar a 0.16 ... 5 bar a 1 ... 30 bar a (0.12 ... 3.63 psi a) (0.62 ... 18.9 psi a) (2.32 ... 72.5 psi a) (14.5 ... 435 psi a) 1 3 D F G H Process connection • Connection shank G½B to EN 837-1 • Female thread ½-14 NPT • Oval flange made of stainless steel - Mounting thread 7/16-20 UNF to EN 61518 - Mounting thread M10 to DIN 19213 • Male thread M20 x 1,5 • Male thread ½-14 NPT Non-wetted parts materials • Housing made of die-cast aluminium • Housing stainless steel precision casting5) Version • Standard version • International version, English label inscriptions, documentation in 5 languages on CD Explosion protection • Without • With ATEX, Type of protection: - "Intrinsic safety (EEx ia)" - "Explosion-proof (EEx d)"6) - "Intrinsic safety and explosion-proof enclosure (EEx ia + EEx d)"7) - "Ex nA/nL (zone 2)" - "Intrinsic safety, explosion-proof enclosure and dust explosion protection (EEx ia + EEx d + Zone 1D/2D)"7) • With FM + CSA, Type of protection: - "Intrinsic safety and explosion-proof (is + xp)"6) Electrical connection / cable entry • Screwed gland Pg 13.58) • Screwed gland M20x1.5 • Screwed gland ½-14 NPT • Han 7D plug (plastic housing) incl. mating connector8) • Plug M12 (metal)9) 6 7 Power supply units see "SITRANS I power supply units and isolation amplifiers". Factory-mounting of shut-off valves and valve manifolds see page 2/142. Included in delivery of the device: • Brief instructions (Leporello) • CD-ROM with detailed documentation Wetted parts materials Seal diaphragm Process connection Stainless steel Stainless steel Hastelloy Stainless steel Hastelloy Hastelloy Version for diaphragm seal2)3)4) 0 1 A B C Y 1) 2) 3) 0 1 4) 2 3 5 6 5) 6) 7) 8) 0 3 9) 1 2 For oxygen application, add Order code E10. Version 7MF4233-1DY... only up to max. span 200 mbar a (2.9 psi a) When the manufacture’s certificate M (calibration certificate) has to be ordered for transmitters with diaphragm seals, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. Whe the acceptance test certificate 3.1 for transmitters with direct-connected diaphragm seals is ordered, this certificate must also be ordered with the corresponding seals. Not together with Electrical connection „Screwed gland Pg 13.5“ and „Han7D plug“. Without cable gland, with blanking plug. With enclosed cable gland EEx ia and blanking plug. Not together with type of protection "Explosion-proof" and type of protection "Ex nA". Not together with types of protection "Explosion-proof" or "Intrinsic safety and explosion-proof" F) Subject to export regulations AL: 9I999, ECCN: N. A B D P E R NC A B C D F Siemens FI 01 · 2009 2/93 2 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for absolute pressure (from gage pressure series) Selection and Ordering data Order No. 2 Order No. Selection and Ordering data SITRANS P pressure transmitters for absolute pressure (from the gage pressure series) SITRANS P pressure transmitters for absolute pressure (from the gage pressure series) DS III PA series (PROFIBUS PA) F) 7 M F 4 2 3 4 - DS III PA series (PROFIBUS PA) F) 7 M F 4 2 3 4 - DS III FF series (FOUNDATION Fieldbus) F) 7 M F 4 2 3 5 - DS III FF series (FOUNDATION Fieldbus) F) 7 M F 4 2 3 5 - 77777 - 7777 Measuring cell filling Silicone oil Inert liquid1) Measuring cell cleaning Standard Grease-free Nominal measuring range 250 mbar a (3.63 psi a) 1300 mbar a (18.9 psi a) 5 bar a (72.5 psi a) 30 bar a (435 psi a) 1 3 D F G H Process connection • Connection shank G½B to EN 837-1 • Female thread ½-14 NPT • Oval flange made of stainless steel - Mounting thread 7/16-20 UNF to EN 61518 - Mounting thread M10 to DIN 19213 • Male thread M20 x 1,5 • Male thread ½-14 NPT Non-wetted parts materials • Housing made of die-cast aluminium • Housing stainless steel precision casting Version • Standard version • International version, English label inscriptions, documentation in 5 languages on CD Explosion protection • Without • With ATEX, Type of protection: - "Intrinsic safety (EEx ia)" - "Explosion-proof (EEx d)"5) - "Intrinsic safety and explosion-proof enclosure (EEx ia + EEx d)"6) - "Ex nA/nL (zone 2)" - "Intrinsic safety, explosion-proof enclosure and dust explosion protection (EEx ia + EEx d + Zone 1D/2D)"6) (not for DS III FF) • With FM + CSA, Type of protection: - "Intrinsic safety and explosion-proof (is + xp)"5) Electrical connection / cable entry • Screwed gland M20x1.5 • Screwed gland ½-14 NPT • Plug M12 incl. mating connector7) 2/94 Siemens FI 01 · 2009 0 1 6 7 Factory-mounting of shut-off valves and valve manifolds see page 2/142. Included in delivery of the device: • Brief instructions (Leporello) • CD-ROM with detailed documentation Wetted parts materials Seal diaphragm Process connection Stainless steel Stainless steel Hastelloy Stainless steel Hastelloy Hastelloy Version as diaphragm seal2)3)4) 77777 - 7777 Display • Without indicator • Without visible digital indicator (digital indicator } hidden, setting: mA) • With visible digital indicator • With customer-specific digital indicator (setting as specified, Order code "Y21" or required) A B C Y 1) 2) 3) 0 1 4) 5) 2 3 5 6 6) 7) For oxygen application, add Order code E10. Version 7MF4233-1DY... only up to max. span 200 mbar a (2.9 psi a). When the manufacture’s certificate M (calibration certificate) has to be ordered for transmitters with diaphragm seals, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. Whe the acceptance test certificate 3.1 for transmitters with direct-connected diaphragm seals is ordered, this certificate must also be ordered with the corresponding seals. Without cable gland, with blanking plug. With enclosed cable gland EEx ia and blanking plug. Not together with types of protection "Explosion-proof" or "Intrinsic safety and explosion-proof" F) Subject to export regulations AL: 9I999, ECCN: N. 0 3 1 2 A B D P E R NC B C F © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for absolute pressure (from gage pressure series) Selection and Ordering data Order code Order code Selection and Ordering data HART PA Further designs FF Additional data HART PA FF Add "-Z" to Order No. and specify Order code. Add "-Z" to Order No. and specify Order code. Pressure transmitter with mounting bracket made of: • Steel • Stainless steel Y01 9 A01 A02 9 9 Measuring range to be set Specify in plain text (max. 5 digits): Y01: ... up to ... mbar, bar, kPa, MPa, psi 9 9 9 A30 A31 9 9 Measuring point number (TAG No.) Max. 16 characters, specify in plain text: Y15: ........................................... Y15 Plug • Han 7D (metal, gray) • Han 8U (instead of Han 7D) 9 9 9 A50 Rating plate inscription (instead of German) • English • French • Spanish • Italian Measuring point text Max. 27 characters, specify in plain text: Y16: ........................................... Y16 Cable sockets for M12 connectors (metal) Entry of HART address (TAG) Max. 8 characters, specify in plain text: Y17: ........................................... Y17 9 Setting of pressure indication in pressure Y21 units Specify in plain text (standard setting: mA): Y21: mbar, bar, kPa, MPa, psi, ... Note: The following pressure units can be selected: bar, mbar, mm H2O*), inH2O*), ftH2O*), mmHG, inHG, psi, Pa, kPa, MPa, g/cm2, kg/cm2, Torr, ATM oder % *) ref. temperature 20 °C 9 9 9 9 9 9 9 9 9 9 9 9 9 B11 B12 B13 B14 9 9 9 9 9 9 9 9 9 9 9 9 B21 9 9 9 Quality inspection certificate (Factory cali- C11 bration) to IEC 60770-2 1) 9 9 9 Acceptance test certificate2) To EN 10204-3.1 C12 9 9 9 Factory certificate To EN 10204-2.2 C14 9 9 9 "Functional Safety (SIL)" certificate C20 9 "PROFIsafe" certificate and protocol C21 Setting of upper limit of output signal to 22.0 mA D05 9 Setting of pressure indication in Y22 + non-pressure units Y01 Specify in plain text: Y22: ..... up to ..... l/min, m3/h, m, USgpm, ... (specification of measuring range in pressure units "Y01" is essential, unit with max. 5 characters) Manufacturer's declaration acc. to NACE D07 9 9 9 Type of protection IP68 (not together with Han 7D / Han 8U plug, Pg 13.5 screwed gland) D12 9 9 9 Preset bus address (possible between 1 and 126) Specify in plain text: Y25: ..................... Digital indicator alongside the input keys (only together with the devices 7MF4233....0-.A.6 or -.A.7-Z, Y21 or Y22 + Y01). D27 9 9 9 Supplied with oval flange (1 item), PTFE packing and screws in thread of oval flange D37 English rating plate Pressure units in inH2O or psi 9 Y25 2 9 Only "Y01", "Y21", "Y22", "Y25" and "D05" can be factory preset 9 = available 1) 9 9 9 2) Use in or on zone 1D/2D E01 (only together with type of protection "Intrinsic safety (EEx ia)") 9 9 9 Use on zone 0 E02 (only together with type of protection "Intrinsic safety (EEx ia)") 9 9 9 Oxygen application (max. 120 bar a (1740 psi a) at 60 °C (140 °F) with oxygen measurement and inert liquid) E10 9 9 9 Explosion-proof "Intrinsic safety" to INMETRO (Brazil) (only for transmitter 7MF4...-.....-.B..) E25 9 9 9 Explosion-proof "Intrinsic safety" to NEPSI E55 (China) (only for transmitter 7MF4...-.....-.B..) 9 9 9 Explosion protection "Explosion-proof" to E56 NEPSI (China) (only for transmitter 7MF4...-.....-.D..) 9 9 9 Explosion-proof "Zone 2" to NEPSI (China) E57 (only for transmitter 7MF4...-.....-.E..) 9 9 9 When the manufacture’s certificate M (calibration certificate) has to be ordered for transmitters with diaphragm seals, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. Whe the acceptance test certificate 3.1 for transmitters with direct-connected diaphragm seals is ordered, this certificate must also be ordered with the corresponding seals. Siemens FI 01 · 2009 2/95 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for absolute pressure (from gage pressure series) ■ Dimensional drawings 117 (4.6) ø 80 (3.15) 20 (0.8) 74 (2.9) 4) ca. 30 (1.2) 100 (3.94) ca. 96 (3.78) 28 (1.1) 6 3 3 1) 8 4 1) 72 (2.8) 1 120 (4.7) 68 (2.7) 5 2 171 (6.7) 237 (9.3) 51 (2.0) 36,5 (1,44) 2 55 (2.2) 144 (5.67) 50 (1.97) 15 (0.6) 123 (4.8) 7 5) min. 90 (3.6) 1 2 3 4 5 6 7 8 105 (4.1) ø 50 ... 60 (1.97 ... 2.36) Process connection: - ½-14 NPT, - onnection shankG½B or - oval flange Blanking plug Electrical connection: - screwed gland Pg 13,5 (adapter)2) 3), - screwed gland M20x1,5 3), - screwed gland ½-14 NPT or - Han 7D/ Han 8U 2) 3) plug Terminal side Electronic side, digital display (longer overall length for cover with window) Protective cover over keys Mounting bracket (option) Screw cover - safety bracket (only for type of protection "Explosion-proof enclosure", not shown in the drawing) 1) 2) 3) 4) 5) Allow approx. 20 mm (0.79 inch) thread length to permit unscrewing Not with type of protection "Explosion-proof enclosure" Not with type of protection "FM + CSA" [is + xp]" For Pg 13,5 with adapter approx. 45 mm (1.77 inch) Minimum distance for rotating SITRANS P pressure transmitters, DS III HART series for absolute pressure, from the pressure series, dimensions in mm (inch) 2/96 Siemens FI 01 · 2009 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for absolute pressure (from gage pressure series) 55 (2.2) approx 30 (1.2) 4) 100 (3.94) 28 (1.1) 6 20 (0.8) 3 1) 8 4 120 (4.7) 68 (2.7) 72 (2.8) 1 36,5 (1,44) 1) 5 2 2 117 (4.6) ø 80 (3.15) 74 (2.9) 51 (2.0) 171 (6.7) 237 (9.3) 144 (5.67) 50 (1.97) 15 (0.6) 123 (4.8) 7 5) min. 90 (3.6) 1 2 3 4 5 6 7 8 105 (4.1) ø 50 ... 60 (1.97 ... 2.36) Process connection: - ½-14 NPT, - connection shank G½B or - oval flange Blanking plug Electrical connection: - screwed gland M20x1,5 4), - screwed gland ½-14 NPT or - PROFIBUS-Stecker M12 3) 4) Terminal side Electronic side, digital display (longer overall length for cover with window) Protective cover over keys Mounting bracket (option) Screw cover - safety bracket (only for type of protection "Explosion-proof enclosure", not shown in the drawing) 1) 2) 3) 4) Allow approx. 20 mm (0.79 inch) thread length in addition Minimum distance for rotating Not with type of protection "Explosion-proof enclosure" Not with type of protection "FM + CSA" SITRANS P pressure transmitters, DS III PA and FF series for absolute pressure, from the pressure series, dimensions in mm (inch) Siemens FI 01 · 2009 2/97 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for absolute pressure (from differential pressure series) ■ Technical specifications SITRANS P, DS III series for absolute pressure (from differential pressure series) HART 2 PROFIBUS PA or FOUNDATION Fieldbus Input Measured variable Absolute pressure pressure Spans (infinitely adjustable) or nominal measuring range and max. permissible working pressure Span Maximum working pres- Nominal measuring sure range Maximum working pressure 8.3 ... 250 mbar a (0.12 ... 3.6 psi a) 32 bar a (464 psi a) 250 mbar a (3.6 psi a) 32 bar a (464 psi a) 43 ... 1300 mbar a (0.62 ... 18.9 psi a) 32 bar a (464 psi a) 1300 bar a (18.9 psi a) 32 bar a (464 psi a) 160 ... 5000 mbar a (2.32 ... 72.5 psi a) 32 bar a (464 psi a) 5 bar a (72.5 psi a) 32 bar a (464 psi a) 1 ... 30 bar a (14.5 ... 435 psi a) 160 bar a (2320 psi a) 30 bar a (435 psi a) 160 bar a (2320 psi a) 5.3 ... 100 bar a (77 ... 1450 psi a) 100 bar a 160 bar a (1450 psi a) (2320 psi a) (for connection thread 7 M10 and /16-20 UNF in the process flanges) 160 bar a (2320 psi a) (for connection thread M10 and 7/16-20 UNF in the process flanges) Lower measuring limit • Measuring cell with silicone oil filling 0 mbar a (0 psi a) Upper measuring limit 100% of max. span Output Output signal 4 ... 20 mA Digital PROFIBUS PA or FOUNDATION Fieldbus signal • Lower limit (infinitely adjustable) 3.55 mA, factory preset to 3.84 mA - • Upper limit (infinitely adjustable) 23 mA, factory preset to 20.5 mA or optionally set to 22.0 mA Load • Without HART communication RB ≤ (UH - 10.5 V)/0.023 A in Ω, UH : Power supply in V - • With HART communication RB = 230 ... 500 Ω (SIMATIC PDM) or RB = 230 ... 1100 Ω (HART Communicator) - Physical bus - IEC 61158-2 With polarity reversal protection - Yes Accuracy To EN 60770-1 Reference conditions (All error data refer always refer to the set span) Increasing characteristic, start-of-scale value 0 bar, stainless steel seal diaphragm, silicone oil filling, room temperature 25 °C (77 °F)) r: Span ratio (r = max. span / set span) Error in measurement and fixed-point setting (including hysteresis and repeatability) ≤ 0.1% • Linear characteristic - r ≤ 10 ≤ 0.1% - 10 < r ≤ 30 ≤ 0.2% Long-term drift (temperature change ± 30 °C ≤ (0.1 ⋅ r)%/year (± 54 °F)) ≤ 0.1%/year Influence of ambient temperature • at -10 ... +60 °C (14 ... 140 °F) ≤ (0.1 ⋅ r +0.2)% ≤ 0.3% • at -40 ... -10 °C and +60 ... +85 °C (-40 ... +14 °F and 140 ... 185 °F) ≤ (0.1 ⋅ r + 0.15)%/10 K ≤ 0.25%/10 K Measured Value Resolution - 3 ⋅ 10-5 of nominal measuring range 2/98 Siemens FI 01 · 2009 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for absolute pressure (from differential pressure series) SITRANS P, DS III series for absolute pressure (from differential pressure series) HART PROFIBUS PA or FOUNDATION Fieldbus Rated operating conditions Degree of protection (to EN 60529) IP65 2 Process temperature • Measuring cell with silicone oil filling -40 ... +100 °C (-40 ... +212 °F) • Measuring cell with inert filling liquid -20 ... +100 °C (-4 ... +212 °F) • In conjunction with dust explosion protection -20 ... +60 °C (-4 ... +140 °F) Ambient conditions • Ambient temperature - Digital indicators -30 ... +85 °C (-22 ... +185 °F) • Storage temperature -50 ... +85 °C (-58 ... +185 °F) • Climatic class - Condensation Permissible • Electromagnetic compatibility - Emitted interference and interference immunity To EN 61326 and NAMUR NE 21 Design Weight (without options) ≈ 4.5 kg (≈ 9.9 lb) Housing material Poor in copper die-cast aluminium, GD-AlSi12 or stainless steel precision casting, mat. No. 1.4408 Wetted parts materials • Seal diaphragm Stainless steel, mat. No. 1.4404/316L or Hastelloy C276, mat. No. 2.4819, Monel, mat. No. 2.4360, tantalum or gold • Process flanges and sealing screw Stainless steel, mat. No. 1.4408, Hastelloy C4, mat. No. 2.4610 or Monel, mat. No. 2.4360 • O-Ring FPM (Viton) or optionally: PTFE, FEP, FEPM and NBR Measuring cell filling Silicone oil or inert filling liquid (max. 160 bar (2320 psi a) with oxygen measurement) Process connection ¼-18 NPT and flange connection to DIN 19213 with mounting thread M10 to DIN 19213 or 16-20 UNF to EN 61518 7/ Material of the mounting bracket • Steel Sheet steel, Mat. No. 1.0330, chrome-plated • Stainless steel Stainless steel, Mat. No. 1.4301 (SS304) Supplied through bus Power supply UH Terminal voltage on transmitter 10.5 ... 45 V DC 10.5 ... 30 V DC in intrinsically-safe mode - Separate 24 V power supply necessary - No Bus voltage • Not Ex - 9 ... 32 V • With intrinsically-safe operation - 9 ... 24 V Current consumption • Basic current (max.) - 12.5 mA • Startup current ≤ basic current - Yes • Max. current in event of fault - 15.5 mA Fault disconnection electronics (FDE) available - Yes Siemens FI 01 · 2009 2/99 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for absolute pressure (from differential pressure series) SITRANS P, DS III series for absolute pressure (from differential pressure series) HART PROFIBUS PA or FOUNDATION Fieldbus Certificate and approvals 2 Classification according to pressure equipment directive (DRGL 97/23/EC) For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of Article 3, paragraph 3 (sound engineering practice) Explosion protection • Intrinsic safety "i" PTB 99 ATEX 2122 - Identification Ex II 1/2 G EEx ia/ib IIB/IIC T6 - Permissible ambient temperature -40 ... +85 °C (-40 ... +185 °F) temperature class T4; -40 ... +70 °C (-40 ... +158 °F) temperature class T5; -40 ... +60 °C (-40 ... +140 °F) temperature class T6 - Connection To certified intrinsically-safe circuits with maximum values: Ui = 30 V, Ii = 100 mA, Pi = 750 mW; Ri = 300 Ω - Effective internal inductance/capacitance L i = 0.4 mH, Ci = 6 nF • Explosion-proof "d" FISCO supply unit: Uo = 17.5 V, Io = 380 mA, Po = 5.32 W Linear barrier: Uo = 24 V, Io = 250 mA, Po = 1.2 W L i = 7 μH, Ci = 1.1 nF PTB 99 ATEX 1160 - Identification Ex II 1/2 G EEx d IIC T4/T6 - Permissible ambient temperature -40 ... +85 °C (-40 ... +185 °F) temperature class T4; -40 ... +60 °C (-40 ... +140 °F) temperature class T6 - Connection • Dust explosion protection for zone 20 - Identification To circuits with values: UH = 10.5 ... 45 V DC Ex II 1 D IP65 T 120 °C Ex II 1/2 D IP65 T 120 °C - Permissible ambient temperature -40 ... +85 °C (-40 ... +185 °F) - Max.surface temperature 120 °C (248 °F) - Connection To certified intrinsically-safe circuits with maximum values: Ui = 30 V, Ii = 100 mA, Pi = 750 mW, Ri = 300 Ω - Effective internal inductance/capacitance L i = 0.4 mH, Ci = 6 nF • Dust explosion protection for zone 21/22 To circuits with values: UH = 9 ... 32 V DC PTB 01 ATEX 2055 FISCO supply unit: Uo = 17.5 V, Io = 380 mA, Po = 5.32 W Linear barrier: Uo = 24 V, Io = 250 mA, Po = 1.2 W L i = 7 μH, Ci = 1.1 nF PTB 01 ATEX 2055 - Identification Ex II 2 D IP65 T 120 °C - Connection To circuits with values: UH = 10.5 ... 45 V DC; Pmax = 1.2 W To circuits with values: UH = 9 ... 32 V DC; Pmax = 1.2 W TÜV 01 ATEX 1696 X Planned Ex II 3 G EEx nA L IIC T4/T5/T6 - • Type of protection "n" (zone 2) - Identification • Explosion protection to FM - Identification (XP/DIP) or (IS); (NI) • Explosion protection to CSA - Identification (XP/DIP) or (IS) 2/100 Siemens FI 01 · 2009 Certificate of Compliance 3008490 CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; CL I, ZN 0/1 AEx ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III Certificate of Compliance 1153651 CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; Ex ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for absolute pressure (from differential pressure series) HART communication HART communication Communication FOUNDATION Fieldbus 230 ... 1100 Ω Protocol HART Version 5.x Software for computer SIMATIC PDM Function blocks 3 function blocks analog input, 1 function block PID • Analog input PROFIBUS PA communication - Adaptation to customer-specif- Yes, linearly rising or falling charic process variables acteristic Simultaneous communication with 4 master class 2 (max.) - Electrical damping T63 , adjust- 0 ... 100 s able The address can be set using - Simulation function Output/input (can be locked within the device with a bridge) - Failure mode Can be parameterized (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively - Square-rooted characteristic for flow measurement Yes Configuration tool or local operation (standard setting address 126) Cyclic data usage • Output byte 5 (one measuring value) or 10 (two measuring values) • Input byte 0, 1, or 2 (register operating mode and reset function for metering) Internal preprocessing Device profile Function blocks PROFIBUS PA Profile for Process Control Devices Version 3.0, Class B • PID • Physical block 1 Resource block 2 Transducer blocks 1 transducer block Pressure with calibration, 1 transducer block LCD • Analog input - Adaptation to customer-specif- Yes, linearly rising or falling charic process variables acteristic - Electrical damping T63 , adjust- 0 ... 100 s able - Simulation function Input /Output - Failure mode Can be parameterized (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively • Register (totalizer) Standard FF function block • Pressure transducer block - Can be calibrated by applying Yes two pressures - Monitoring of sensor limits Yes - Simulation function: Measured Constant value or over parameterpressure value, sensor temper- izable ramp function ature and electronics temperature Can be reset, preset, optional direction of counting, simulation function of register output - Failure mode Can be parameterized (summation with last good value, continuous summation, summation with incorrect value) - Limit monitoring One upper and lower warning limit and one alarm limit respectively • Physical block 1 Transducer blocks 2 • Pressure transducer block - Can be calibrated by applying Yes two pressures - Monitoring of sensor limits Yes - Specification of a container characteristic with Max. 30 nodes - Square-rooted characteristic for flow measurement Yes - Gradual volume suppression and implementation point of square-root extraction Parameterizable - Simulation function for meaConstant value or over parametersured pressure value and sen- izable ramp function sor temperature Siemens FI 01 · 2009 2/101 2 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for absolute pressure (from differential pressure series) Order No. Selection and Ordering data 2 Selection and Ordering data Order No. SITRANS P pressure transmitters for absolute F) 7 M F 4 3 3 3 pressure, from the differential pressure, 77777 - 7777 series DS III HART SITRANS P pressure transmitters for absolute F) 7 M F 4 3 3 3 pressure, from the differential pressure, 77777 - 7777 series DS III HART Measuring cell filling Display • Without indicator • Without visible digital indicator (digital indicator } hidden, setting: mA) • With visible digital indicator • With customer-specific digital indicator (setting as specified, Order code "Y21" or required) Silicone oil Inert liquid1) Measuring cell cleaning Standard Grease-free Span 8.3 ... 250 mbar a 43 ... 1300 mbar a 0.16 ... 5 bar a 1 ... 30 bar a 5.3 ... 100 bar a (0.12 ... 3.63 psi a) (0.62 ... 18.9 psi a) (2.32 ... 72.5 psi a) (14.5 ... 435 psi a) (76.9 ... 1450 psi a) 1 3 E) E) E) D F G H KE Process connection Female thread ¼-18 NPT with flange connection • Sealing screw opposite process connection - Mounting thread 7/16-20 UNF to EN 61518 - Mounting thread M10 to DIN 19213 (only for replacement needs) • Vent on side of process flange5) - Mounting thread 7/16-20 UNF to EN 61518 - Mounting thread M10 to DIN 19213 (only for replacement needs) E) Factory-mounting of shut-off valves and valve manifolds see page 2/142. Included in delivery of the device: • Brief instructions (Leporello) • CD-ROM with detailed documentation • Sealing plug(s) or sealing screw(s) for the process flanges(s) A B C E H L Y 1) For oxygen applications, add Order code E10. Version 7MF4333-1DY... only up to max. span 200 mbar a (2.9 psi a). 3) When the manufacture’s certificate M (calibration certificate) has to be ordered for transmitters with diaphragm seals, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. 4) Whe the acceptance test certificate 3.1 for transmitters with direct-connected diaphragm seals is ordered, this certificate must also be ordered with the corresponding seals. 5) Not for span "5.3 ... 100 bar a (76.9 ... 1450 psi a)". Position of the top vent valve in the process flange (see dimensional drawing). 6) Not together with Electrical connection „Screwed gland Pg 13.5“ and „Han7D plug“. 7) Without cable gland, with blanking plug 8) With enclosed cable gland EEx ia and blanking plug 9) Not together with type of protection "Explosion-proof" and and type of protection "Ex nA". 10) Not together with types of protection "Explosion-proof" or "Intrinsic safety and explosion-proof" 2) 2 0 6 4 Non-wetted parts materials Process flange screws Electronics housing Stainless steel Stainless steel Die-cast aluminium Stainless steel precision casting6) Version • Standard version • International version, English label inscriptions, documentation in 5 languages on CD Explosion protection • Without • With ATEX, Type of protection: - "Intrinsic safety (EEx ia)" - "Explosion-proof (EEx d)"7) - "Intrinsic safety and explosion-proof enclosure (EEx ia + EEx d)" 8) - "Ex nA/nL (zone 2)" - "Intrinsic safety, explosion-proof enclosure and dust explosion protection (EEx ia + EEx d + Zone 1D/2D)"8) • With FM + CSA, Type of protection: - "Intrinsic safety and explosion-proof (is + xp)"7) Electrical connection / cable entry • Screwed gland Pg 13.59) • Screwed gland M20x1.5 • Screwed gland ½-14 NPT • Han 7D plug (plastic housing) incl. mating connector9) • Plug M12 (metal)10) 2/102 Siemens FI 01 · 2009 6 7 Power supply units see "SITRANS I power supply units and isolation amplifiers". Wetted parts materials Seal diaphragm Parts of measuring cell Stainless steel Stainless steel Hastelloy Stainless steel Hastelloy Hastelloy Tantalum Tantalum Monel Monel Gold Gold Version for diaphragm seal2)3)4) 0 1 E) Combinations of the versions marked with E) are subject to the export regulations AL: 2B230, ECCN: N. F) Subject to export regulations AL: 9I999, ECCN: N. 2 3 1 2 A B D P E R NC A B C D F © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for absolute pressure (from differential pressure series) Order No. Selection and Ordering data Order No. Selection and Ordering data SITRANS P pressure transmitters for absolute pressure (from the differential pressure series) SITRANS P pressure transmitters for absolute pressure (from the differential pressure series) DS III PA series (PROFIBUS PA) F) 7 M F 4 3 3 4 - DS III PA series (PROFIBUS PA) F) 7 M F 4 3 3 4 - DS III FF series (FOUNDATION Fieldbus) F) 7 M F 4 3 3 5 - DS III FF series (FOUNDATION Fieldbus) F) 7 M F 4 3 3 5 - 77777 - 7777 Measuring cell filling Silicone oil Inert liquid1) Measuring cell cleaning Standard Grease-free Nominal measuring range 250 mbar a (3.63 psi a) 1300 mbar a (18.9 psi a) 5 bar a (72.5 psi a) 30 bar a (435 psi a) 100 bar a (1450 psi a) 1 3 E) E) E) D F G H KE E) A B C E H L Y 1) 2) 3) 4) Process connection Female thread ¼-18 NPT with flange connection • Sealing screw opposite process connection - Mounting thread 7/16-20 UNF to EN 61518 - Mounting thread M10 to DIN 19213 (only for replacement needs) • Vent on side of process flange5) 7 - Mounting thread /16-20 UNF to EN 61518 - Mounting thread M10 to DIN 19213 (only for replacement needs) 0 1 6 7 Factory-mounting of shut-off valves and valve manifolds see page 2/142. Included in delivery of the device: • Brief instructions (Leporello) • CD-ROM with detailed documentation • Sealing plug(s) or sealing screw(s) for the process flanges(s) Wetted parts materials Seal diaphragm Parts of measuring cell Stainless steel Stainless steel Hastelloy Stainless steel Hastelloy Hastelloy Tantalum Tantalum Monel Monel Gold Gold Version as diaphragm seal2)3)4) 77777 - 7777 Display • Without indicator • Without visible digital indicator (digital indicator } hidden, setting: mA) • With visible digital indicator • With customer-specific digital indicator (setting as specified, Order code "Y21" or required) 5) 6) 7) 2 0 8) For oxygen application, add Order code E10. Version 7MF4334-1DY... only up to max. span 200 mbar a (2.9 psi a). When the manufacture’s certificate M (calibration certificate) has to be ordered for transmitters with diaphragm seals, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. Whe the acceptance test certificate 3.1 for transmitters with direct-connected diaphragm seals is ordered, this certificate must also be ordered with the corresponding seals. Not for nominal measuring range 100 bar a (1450 psi a). Position of the top vent valve in the process flange (see dimensional drawing). Without cable gland, with blanking plug With enclosed cable gland EEx ia and blanking plug Cannot be used together with the following types of protection: "Explosion-proof" and "Intrinsic safety and explosion-proof". E) Combinations of the versions marked with E) are subject to the export regulations AL: 2B230, ECCN: N. F) Subject to export regulations AL: 9I999, ECCN: N. 6 4 Non-wetted parts materials Process flange screws Electronics housing Stainless steel Stainless steel Die-cast aluminium Stainless steel precision casting Version • Standard version • International version, English label inscriptions, documentation in 5 languages on CD Explosion protection • Without • With ATEX, Type of protection: - "Intrinsic safety (EEx ia)" - "Explosion-proof (EEx d)"6) - "Intrinsic safety and explosion-proof enclosure (EEx ia + EEx d)"7) - "Ex nA/nL (zone 2)" - "Intrinsic safety, explosion-proof enclosure and dust explosion protection (EEx ia + EEx d + Zone 1D/2D)"7) (not for DS III FF) • With FM + CSA, Type of protection: - "Intrinsic safety and explosion-proof (is + xp)"6) Electrical connection / cable entry • Screwed gland M20x1.5 • Screwed gland ½-14 NPT • M12 Connector (metall)8) 2 3 1 2 A B D P E R NC B C F Siemens FI 01 · 2009 2/103 2 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for absolute pressure (from differential pressure series) Selection and Ordering data Order code 2 Selection and Ordering data HART PA Further designs FF Order code HART PA Further designs FF Add "-Z" to Order No. and specify Order code. Add "-Z" to Order No. and specify Order code. Pressure transmitter with mounting bracket made of: • Steel • Stainless steel 9 9 9 A01 A02 9 9 9 9 9 9 Explosion-proof "Intrinsic safety" to NEPSI E55 (China) (only for transmitter 7MF4...-.....-.B..) Explosion protection "Explosion-proof" to E56 NEPSI (China) (only for transmitter 7MF4...-.....-.D..) 9 9 9 O-rings for process flanges (instead of FPM (Viton)) • PTFE (Teflon) • FEP (with silicone core, approved for food) • FFPM (Kalrez, compound 4079) • NBR (Buna N) A20 A21 A22 A23 9 9 9 9 9 9 9 9 9 9 9 9 Explosion-proof "Zone 2" to NEPSI (China) E57 (only for transmitter 7MF4...-.....-.E..) 9 9 9 Interchanging of process connection side H01 9 9 9 Plug • Han 7D (metal, gray) • Han 8U (instead of Han 7D) Vent on side for gas measurements H02 9 9 9 A30 A31 9 9 Sealing screws ¼-18 NPT, with valve in material of process flanges A40 9 9 9 9 9 9 9 9 9 9 9 9 Cable sockets for M12 connectors (metal) A50 9 9 9 Process flange • Hastelloy K01 • Monel K02 • Stainless steel with PVDF insert K04 max. PN 10 (MWP 145 psi), max. temperature of medium 90 °C (194 °F) Rating plate inscription (instead of German) • English • French • Spanish • Italian B11 B12 B13 B14 9 9 9 9 9 9 9 9 9 9 9 9 B21 9 9 9 Quality inspection certificate (Factory cali- C11 bration) to IEC 60770-2 1) 9 9 9 Acceptance test certificate2) To EN 10204-3.1 C12 9 9 9 Factory certificate To EN 10204-2.2 C14 9 9 9 "Functional Safety (SIL)" certificate C20 9 "PROFIsafe" certificate and protocol C21 Setting of upper limit of output signal to 22.0 mA D05 9 Manufacturer's declaration acc. to NACE (only together with seal diaphragm made of Hastelloy and stainless steel) D07 9 9 9 Type of protection IP68 (not together with Han 7D/Han 8U plug, cable gland PG 13.5) D12 9 9 9 Digital indicator alongside the input keys (only together with the devices 7MF4333....2-.A.6 or -.A.7-Z, Y21 or Y22 + Y01) D27 9 9 9 Supplied with oval flange (1 item), PTFE packing and stainless steel screws in thread of process flange D37F) English rating plate Pressure units in inH2O or psi 9 For ½-14 NPT inner process connection on the side in the middle of the process flange, vent valve not possible Additional data Add "-Z" to Order No. and specify Order code. Measuring range to be set Specify in plain text (max. 5 digits): Y01: ... up to ... mbar, bar, kPa, MPa, psi Y01 9 Measuring point number (TAG No.) Max. 16 characters, specify in plain text: Y15: ........................................... Y15 9 9 9 Measuring point text Max. 27 characters, specify in plain text: Y16: ........................................... Y16 9 9 9 Entry of HART address (TAG) Max. 8 characters, specify in plain text: Y17: ........................................... Y17 9 Setting of pressure indication in pressure Y21 units Specify in plain text (standard setting: mA): Y21: mbar, bar, kPa, MPa, psi, ... Note: The following pressure units can be selected: bar, mbar, mm H2O*), inH2O*), ftH2O*), mmHG, inHG, psi, Pa, kPa, MPa, g/cm2, kg/cm2, Torr, ATM oder % *) ref. temperature 20 °C 9 9 9 Setting of pressure indication in Y22 + non-pressure units Y01 Specify in plain text: 3 Y22: ..... up to ..... l/min, m /h, m, USgpm, ... (specification of measuring range in pressure units "Y01" is essential, unit with max. 5 characters) 9 9 9 9 Use in or on zone 1D/2D E01 (only together with type of protection "Intrinsic safety (EEx ia)") 9 9 9 Use on zone 0 E02 (only together with type of protection "Intrinsic safety (EEx ia)") 9 9 9 Preset bus address (possible between 1 and 126) Specify in plain text: Y25: ..................... Oxygen application (max. 120 bar a (1740 psi a) at 60°C (140 °F) with oxygen measurement and inert liquid) E10 9 9 9 Only "Y01", "Y21", "Y22", "Y25" and "D05" can be factory preset 9 = available Explosion-proof "Intrinsic safety" to INMETRO (Brazil) (only for transmitter 7MF4...-.....-.B..) E25 1) 9 9 9 2) Y25 When the manufacture’s certificate M (calibration certificate) has to be ordered for transmitters with diaphragm seals, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. Whe the acceptance test certificate 3.1 for transmitters with direct-connected diaphragm seals is ordered, this certificate must also be ordered with the corresponding seals. F) Subject to export regulations AL: 9I999, ECCN: N. 2/104 Siemens FI 01 · 2009 9 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for absolute pressure (from differential pressure series) ■ Dimensional drawings 3 approx. 261 (10.3) 9 134 (5.27) 1 + Space for rotation of housing 10 8 7 11 ø 50 ... 60 (1.97 ... 2.36) approx. 96 (3.78) 3 72 (2.83) 105 (4.1) 1 2 3 4 5 6 7 8 9 10 11 Process connection: ¼-18 NPT (EN 61518) Blanking plug Electrical connection: - screwed gland Pg 13,5 (adapter) 2) 3), - screwed gland M20x1,5 3), - screwed gland ½-14 NPT or - Han 7D/ Han 8U plug 2) 3) Terminal side Electronics side, digital display (longer overall length for cover with window) Protective cover over keys Mounting bracket (option) Sealing screw with valve (option) Screw cover - safety bracket (only for type of protection "Explosion-proof enclosure", not shown in the drawing) Lateral venting for liquid measurement (Standard) Lateral venting for gas measurement (suffix H02) 52 (2.05) 96 (3.8) 117 (4.6) 1) 4 69 (2.7) 90 (3.6)4) 2 2 6 50 (1.97) Ø 80 (3.15) 5 1) 100 (3.94) approx. 30 (1.2) 5) 51 (2.0) 198 (7.8) 144 (5.67) 20 (0.8) 15 (0.6) 68 (2.7) 120 (4.7) 1) 2) 3) 4) 5) Allow approx. 20 mm (0.79 inch) thread length to permit unscrewing Not with type of protection "explosion-proof enclosure" Not with type of protection "FM + CSA [is + xp]" 92 mm (3.62 inch) for minimum distance to permit rotation with indicator 45 mm (1.8 inch) for Pg 13,5 with adapter SITRANS P pressure transmitters, DS III HART series for absolute pressure, from the differential pressure series, dimensions in mm (inch) Siemens FI 01 · 2009 2/105 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for absolute pressure (from differential pressure series) approx. 30 (1.2) 2 6 approx. 261 (10.3) 9 1 + Space for rotation of housing 10 8 7 52 (2.05) ø 50 ... 60 (1.97 ... 2.36) 11 96 (3.8) 1) 4 3 198 (7.8) 117 (4.6) Ø 80 (3.15) 5 1) 100 (3.94) 50 (1.97) 51 (2.0) 69 (2.7) 90 (3.6)2) 134 (5.27) 2 144 (5.67) 20 (0.8) 15 (0.6) 72 (2.83) 105 (4.1) 1 2 3 4 5 6 7 8 9 10 11 Process connection: ¼-18 NPT (EN 61518) Blanking plug Electrical connection: - screwed gland M20x1,5 4), - screwed gland ½-14 NPT or - PROFIBUS plug M12 3) 4) Terminal side Electronic side, digital display (longer overall length for cover with window) Protective cover over keys Mounting bracket (option) Sealing screw with valve (option) Screw cover safety bracket (only for explosion-proof enclosure, not shown in the drawing) Lateral venting for liquid measurement (Standard) Lateral venting for gas measurement (suffix H02) 68 (2.7) 120 (4.7) 1) 2) 3) 4) Allow approx. 20 mm (0.79 inch) thread length in addition 92 mm (3.62 inch) for minimum distance to permit rotation with indicator Not with type of protection "explosion-proof enclosure" Not with type of protection "FM + CSA" SITRANS P pressure transmitters, DS III PA and FF series for absolute pressure, from the differential pressure series, dimensions in mm (inch) 2/106 Siemens FI 01 · 2009 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for differential pressure and flow ■ Technical specifications SITRANS P, DS III series, for differential pressure and flow HART PROFIBUS PA or FOUNDATION Fieldbus Input Measured variable Differential pressure and flow Spans (infinitely adjustable) or nominal measuring range and max. permissible working pressure Span 2 Maximum working pres- Nominal measuring sure range Maximum working pressure 1 ... 20 mbar 32 bar (0.4015 ... 8.031 inH2O) (464 psi) 20 mbar g (8.031 inH2O) 32 bar (464 psi) 160 bar 1 ... 60 mbar (0.4015 ... 24.09 inH2O) (2320 psi) 60 mbar (24.09 inH2O) 160 bar (2320 psi) 2.5 ... 250 mbar (1.004 ... 100.4 inH2O) 250 mbar (100.4 inH2O) 6 ... 600 mbar (2.409 ... 240.9 inH2O) 600 mbar (240.9 inH2O) 16 ... 1600 mbar (6.424 ... 642.4 inH2O) 1600 mbar (642.4 inH2O) 50 ... 5000 mbar (20.08 ... 2008 inH2O) 5 bar (2008 inH2O) 0.3 ... 30 bar (4.35 ... 435 psi) 30 bar (435 psi) 2.5 ... 250 mbar (1.004 ... 100.4 inH2O) 420 bar (6091 psi) 250 mbar (100.4 inH2O) 6 ... 600 mbar (2.409 ... 240.9 inH2O) 600 mbar (240.9 inH2O) 16 ... 1600 mbar (6.424 ... 642.4 inH2O) 1600 mbar (642.4 inH2O) 50 ... 5000 mbar (20.08 ... 2008 inH2O) 5 bar (2008 inH2O) 0.3 ... 30 bar (4.35 ... 435 psi) 30 bar (435 psi) 420 bar (6091 psi) Lower measuring limit • Measuring cell with silicone oil filling -100% of max. span (-33% with 30 bar (435 psi) measuring cell or 30 mbar a (0.44 psi)) Upper measuring limit 100% of max. span (for oxygen version and inert filling liquid; max. 160 bar g (2320 psi g)) Output Output signal 4 ... 20 mA Digital PROFIBUS PA or FOUNDATION Fieldbus signal • Lower limit (infinitely adjustable) 3.55 mA, factory preset to 3.84 mA - • Upper limit (infinitely adjustable) 23 mA, factory preset to 20.5 mA or optionally set to 22.0 mA Load • Without HART communication RB ≤ (UH - 10.5 V)/0.023 A in Ω, UH : Power supply in V - • With HART communication RB = 230 ... 500 Ω (SIMATIC PDM) or RB = 230 ... 1100 Ω (HART Communicator) - Physical bus - IEC 61158-2 With polarity reversal protection - Yes Accuracy To EN 60770-1 Reference conditions (All error data refer always refer to the set span) Increasing characteristic, start-of-scale value 0 bar, stainless steel seal diaphragm, silicone oil filling, room temperature 25 °C (77 °F)) r: Span ratio (r = max. span / set span) Error in measurement and fixed-point setting (including hysteresis and repeatability) ≤ 0,075% • Linear characteristic - r ≤ 10 ≤ (0.0029 ⋅ r + 0.071)% - 10 < r ≤ 30 ≤ (0.0045 ⋅ r + 0.071)% - 30 < r ≤ 100 ≤ (0.005 ⋅ r + 0.05)% ≤ 0,1% • Square-root characteristic (flow > 50%) - r ≤ 10 ≤ 0,1% - 10 < r ≤ 30 ≤ 0,2% Siemens FI 01 · 2009 2/107 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for differential pressure and flow SITRANS P, DS III series, for differential pressure and flow HART 2 PROFIBUS PA or FOUNDATION Fieldbus ≤ 0,2 • Square-root characteristic (flow 25 ... 50%) - r ≤ 10 ≤ 0,2% - - 10 < r ≤ 30 ≤ 0,4% - Long-term drift (temperature change ± 30 °C ≤ (0.25 ⋅ r)% every 5 years (± 54 °F)) static pressure max. 70 bar g (1015 psi g) ≤ (0.25% every 5 years static pressure max. 70 bar g (1015 psi g) ≤ (0.2 ⋅ r) per year ≤ 0.2 per year • at -10 ... +60 °C (14 ... 140 °F) ≤ (0.08 ⋅ r + 0.1)% ≤ 0,3% • at -40 ... -10 °C and +60 ... +85 °C (-40 ... +14 °F and 140 ... 185 °F) ≤ (0.1 ⋅ r + 0.15)%/10 K (Twice the value with 20-mbar (0.29 psi) measuring cell) ≤ 0.25%/10 K • on the zero point - 20 mbar (0.29 psi)-measuring cell ≤ (0.15 ⋅ r)% per 100 bar (1450 psi) ≤ 0.15% je 100 bar (1450 psi) ≤ (0.15 ⋅ r)% per 32 bar (464 psi) ≤ 0.15% je 32 bar (464 psi) • on the span - 20 mbar (0.29 psi)-measuring cell ≤ 0.2% je 100 bar (1450 psi) - ≤ 0.2% je 32 bar (464 psi) - Measured Value Resolution - 3 ⋅ 10-5 of nominal measuring range • 20 mbar (0.29 psi)-measuring cell Influence of ambient temperature Influence of static pressure Rated operating conditions Degree of protection (to EN 60529) IP65 Process temperature • Measuring cell with silicone oil filling -40 ... +100 °C (-40 ... +212 °F) • Measuring cell with inert filling liquid -20 ... +100 °C (-4 ... +212 °F) • In conjunction with dust explosion protection -20 ... +60 °C (-4 ... +140 °F) Ambient conditions • Ambient temperature - Digital indicators -30 ... +85 °C (-22 ... +185 °F) • Storage temperature -50 ... +85 °C (-58 ... +185 °F) • Climatic class - Condensation Permissible • Electromagnetic compatibility - Emitted interference and interference immunity To EN 61326 and NAMUR NE 21 Material of the mounting bracket • Steel Sheet steel, Mat. No. 1.0330, chrome-plated • Stainless steel Stainless steel, Mat. No. 1.4301 (SS304) Design Weight (without options) ≈ 4.5 kg (≈ 9.9 lb) Housing material Poor in copper die-cast aluminium, GD-AlSi12 or stainless steel precision casting, mat. No. 1.4408 Wetted parts materials • Seal diaphragm Stainless steel, mat. No. 1.4404/316L or Hastelloy C276, mat. No. 2.4819, Monel, mat. No. 2.4360, tantalum or gold Measuring cell filling Silicone oil or inert filling liquid (max. 160 bar (2320 psi g) with oxygen measurement) Process connection Female thread ¼-18 NPT and flange connection with mounting thread M10 to DIN 19213 or 7/ -20 UNF to EN 61518 16 2/108 Siemens FI 01 · 2009 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for differential pressure and flow SITRANS P, DS III series, for differential pressure and flow HART PROFIBUS PA or FOUNDATION Fieldbus Terminal voltage on transmitter 10.5 ... 45 V DC 10.5 ... 30 V DC in intrinsically-safe mode - Separate 24 V power supply necessary - No Supplied through bus Power supply UH 2 Bus voltage • Not Ex - 9 ...32 V • With intrinsically-safe operation - 9 ...24 V Current consumption • Basic current (max.) - 12.5 mA • Startup current ≤ basic current - Yes • Max. current in event of fault - 15.5 mA Fault disconnection electronics (FDE) avail. - Yes Siemens FI 01 · 2009 2/109 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for differential pressure and flow SITRANS P, DS III series, for differential pressure and flow HART PROFIBUS PA or FOUNDATION Fieldbus Certificate and approvals 2 Classification according to pressure equipment directive (DRGL 97/23/EC) PN 32/160 (MWP 464/2320 psi) For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of Article 3, paragraph 3 (sound engineering practice) PN 420 (MWP 6092 psi) For gases of fluid group 1 and liquids of fluid group 1; complies with basic safety requirements of Article 3, paragraph 1 (appendix 1); assigned to category III, conformity evaluation module H by the TÜV Nord. Explosion protection • Intrinsic safety "i" PTB 99 ATEX 2122 - Identification Ex II 1/2 G EEx ia/ib IIB/IIC T6 - Permissible ambient temperature -40 ... +85 °C (-40 ... +185 °F) temperature class T4; -40 ... +70 °C (-40 ... +158 °F) temperature class T5; -40 ... +60 °C (-40 ... +140 °F) temperature class T6 - Connection To certified intrinsically-safe circuits with maximum values: Ui = 30 V, Ii = 100 mA, Pi = 750 mW; Ri = 300 Ω - Effective internal inductance/capacitance L i = 0.4 mH, Ci = 6 nF • Explosion-proof "d" FISCO supply unit: Uo = 17.5 V, Io = 380 mA, Po = 5.32 W Linear barrier: Uo = 24 V, Io = 250 mA, Po = 1.2 W L i = 7 μH, Ci = 1.1 nF PTB 99 ATEX 1160 - Identification Ex II 1/2 G EEx d IIC T4/T6 - Permissible ambient temperature -40 ... +85 °C (-40 ... +185 °F) temperature class T4; -40 ... +60 °C (-40 ... +140 °F) temperature class T6 - Connection • Dust explosion protection for zone 20 - Identification To circuits with values: UH = 10.5 ... 45 V DC Ex II 1 D IP65 T 120 °C Ex II 1/2 D IP65 T 120 °C - Permissible ambient temperature -40 ... +85 °C (-40 ... +185 °F) - Max.surface temperature 120 °C (248 °F) - Connection To certified intrinsically-safe circuits with maximum values: Ui = 30 V, Ii = 100 mA, Pi = 750 mW, Ri = 300 Ω - Effective internal inductance/capacitance L i = 0.4 mH, Ci = 6 nF • Dust explosion protection for zone 21/22 To circuits with values: UH = 9 ... 32 V DC PTB 01 ATEX 2055 FISCO supply unit: Uo = 17.5 V, Io = 380 mA, Po = 5.32 W Linear barrier: Uo = 24 V, Io = 250 mA, Po = 1.2 W L i = 7 μH, Ci = 1.1 nF PTB 01 ATEX 2055 - Identification Ex II 2 D IP65 T 120 °C - Connection To circuits with values: UH = 10.5 ... 45 V DC; Pmax = 1.2 W To circuits with values: UH = 9 ... 32 V DC; Pmax = 1.2 W TÜV 01 ATEX 1696 X Planned Ex II 3 G EEx nA L IIC T4/T5/T6 - • Type of protection "n" (zone 2) - Identification • Explosion protection to FM - Identification (XP/DIP) or (IS); (NI) • Explosion protection to CSA - Identification (XP/DIP) or (IS) 2/110 Siemens FI 01 · 2009 Certificate of Compliance 3008490 CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; CL I, ZN 0/1 AEx ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III Certificate of Compliance 1153651 CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; Ex ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for differential pressure and flow HART communication HART communication Communication FOUNDATION Fieldbus 230 ... 1100 Ω Protocol HART Version 5.x Software for computer SIMATIC PDM Function blocks 3 function blocks analog input, 1 function block PID • Analog input PROFIBUS PA communication - Adaptation to customer-specif- Yes, linearly rising or falling charic process variables acteristic Simultaneous communication with 4 master class 2 (max.) - Electrical damping T63 , adjust- 0 ... 100 s able The address can be set using - Simulation function Output/input (can be locked within the device with a bridge) - Failure mode Can be parameterized (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively - Square-rooted characteristic for flow measurement Yes Configuration tool or local operation (standard setting address 126) Cyclic data usage • Output byte 5 (one measuring value) or 10 (two measuring values) • Input byte 0, 1, or 2 (register operating mode and reset function for metering) Internal preprocessing Device profile Function blocks PROFIBUS PA Profile for Process Control Devices Version 3.0, Class B • PID • Physical block 1 Resource block 2 Transducer blocks 1 transducer block Pressure with calibration, 1 transducer block LCD • Analog input - Adaptation to customer-specif- Yes, linearly rising or falling charic process variables acteristic - Electrical damping T63 , adjust- 0 ... 100 s able - Simulation function Input /Output - Failure mode Can be parameterized (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively • Register (totalizer) Standard FF function block • Pressure transducer block - Can be calibrated by applying Yes two pressures - Monitoring of sensor limits Yes - Simulation function: Measured Constant value or over parameterpressure value, sensor temper- izable ramp function ature and electronics temperature Can be reset, preset, optional direction of counting, simulation function of register output - Failure mode Can be parameterized (summation with last good value, continuous summation, summation with incorrect value) - Limit monitoring One upper and lower warning limit and one alarm limit respectively • Physical block 1 Transducer blocks 2 • Pressure transducer block - Can be calibrated by applying Yes two pressures - Monitoring of sensor limits Yes - Specification of a container characteristic with Max. 30 nodes - Square-rooted characteristic for flow measurement Yes - Gradual volume suppression and implementation point of square-root extraction Parameterizable - Simulation function for meaConstant value or over parametersured pressure value and sen- izable ramp function sor temperature Siemens FI 01 · 2009 2/111 2 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for differential pressure and flow 2 Selection and Ordering data Order No. Selection and Ordering data Order No. SITRANS P pressure transmitters for differential pressure and flow, Series DS III HART PN 32/160 (MWP 464/2320 psi) 7MF 4 4 3 3 - SITRANS P pressure transmitters for differential pressure and flow, Series DS III HART PN 32/160 (MWP 464/2320 psi) 77777 - 7777 Measuring cell filling Silicone oil Inert liquid1) Measuring cell cleaning Standard Grease-free 77777 - 7777 Display • Without indicator • Without visible digital indicator (digital indicator } hidden, setting: mA) • With visible digital indication • With customer-specific digital indication (setting as specified, Order code "Y21" or required) } 1 3 Span PN 32 (MWP 464 psi) 1 ... 20 mbar2) (0.4015 ... 8.03 inH2O) } B PN 160 (MWP 2320 psi) 1 ... 60 mbar 2.5 ... 250 mbar 6 ... 600 mbar 16 ... 1600 mbar 50 ... 5000 mbar 0.3 ... 30 bar (0.4015 ... 24.09 inH2O) (1.004 ... 100.4 inH2O) (2.409 ... 240.9 inH2O) (6.424 ... 642.4 inH2O) (20.08 ... 2008 inH2O) (4.35 ... 435 psi) } } } } } } C D E F G H Factory-mounting of shut-off valves and valve manifolds see page 2/142. Included in delivery of the device: • Brief instructions (Leporello) • CD-ROM with detailed documentation • Sealing plug(s) or sealing screw(s) for the process flanges(s) For oxygen application, add Order code E10. Not suitable for connection of remote seal. Position of the top vent valve in the process flanges (see dimensional drawing). 3) Only together with max. spans 250, 1600, 5000 and 30000 mbar (100.4, 240.9, 2008 inH2O and 435 psi) 4) When the manufacture’s certificate M (calibration certificate) has to be ordered for transmitters with diaphragm seals, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. 5) Whe the acceptance test certificate 3.1 for transmitters with direct-connected diaphragm seals is ordered, this certificate must also be ordered with the corresponding seals. 6) Not together with Electrical connection „Screwed gland Pg 13.5“ and „Han7D plug“. 7) Without cable gland, with blanking plug 8) With enclosed cable gland EEx ia and blanking plug 9) Not together with type of protection "Explosion-proof" and and type of protection "Ex nA". 10) Cannot be used together with the following types of protection: "Explosion-proof" and "Intrinsic safety and explosion-proof" 2) Process connection Female thread ¼-18 NPT with flange connection • Sealing screw opposite process connection - Mounting thread 7/16-20 UNF to EN 61518 - Mounting thread M10 to DIN 19213 } (only for replacement needs) 2) • Vent on side of process flange - Mounting thread 7/16-20 UNF to EN 61518 - Mounting thread M10 to DIN 19213 (only for replacement needs) A B C E H L Y 2 0 6 4 Non-wetted parts materials Process flange screws Electronics housing Stainless steel Stainless steel Die-cast aluminium } Stainless steel precision 6) casting Version • Standard version • International version, English label inscriptions, } documentation in 5 languages on CD Explosion protection • Without • With ATEX, Type of protection: - "Intrinsic safety (EEx ia)" - "Explosion-proof (EEx d)"7) - "Intrinsic safety and explosion-proof enclosure (EEx ia + EEx d)"8) - "Intrinsic safety, explosion-proof enclosure and dust explosion protection (EEx ia + EEx d + Zone 1D/2D)"8) • With FM + CSA, Type of protection: - "Intrinsic safety and explosion-proof (is + xp)"7) Electrical connection / cable entry • Screwed gland Pg 13.59) • Screwed gland M20x1.5 • Screwed gland ½-14 NPT • Han 7D plug (plastic housing) incl. mating connector10) • M12 connectors (metal)10) 2/112 Siemens FI 01 · 2009 2 3 1 2 A B D P - "Ex nA/nL (zone 2)" } E R NC } 6 7 Power supply units see "SITRANS I power supply units and isolation amplifiers". 1) } 0 1 } Available ex stock Wetted parts materials (stainless steel process flanges) Seal diaphragm Parts of measuring cell Stainless steel Stainless steel Hastelloy Stainless steel Hastelloy Hastelloy Tantalum3) Tantalum Monel3) Monel Gold3) Gold Version for diaphragm seal4) 5) 7MF 4 4 3 3 - A B C D F © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for differential pressure and flow Selection and Ordering data Order No. Order No. Selection and Ordering data SITRANS P pressure transmitters for differential pressure and flow PN 32/160 (MWP 464/2320 psi) SITRANS P pressure transmitters for differential pressure and flow PN 32/160 (MWP 464/2320 psi) DS III PA series (PROFIBUS PA) 7MF 4 4 3 4 - DS III PA series (PROFIBUS PA) DS III FF series (FOUNDATION Fieldbus) 7MF 4 4 3 5 - DS III FF series (FOUNDATION Fieldbus) 7MF 4 4 3 4 - 77777 - 7777 Measuring cell filling Silicone oil Inert liquid1) Measuring cell cleaning Standard Grease-free Electrical connection / cable entry • Screwed gland M20x1.5 • Screwed gland ½-14 NPT • M12 connectors (metal)8) 1 3 Nominal measuring range PN 32 (MWP 464 psi) 20 mbar2) (8.03 inH2O) B PN 160 (MWP 2320 psi) 60 mbar 250 mbar 600 mbar 1600 mbar 5 bar 30 bar C D E F G H (24.09 inH2O) (100.4 inH2O) (240.9 inH2O) (642.4 inH2O) (2008 inH2O) (435 psi) 0 1 6 7 Factory-mounting of shut-off valves and valve manifolds see page 2/142. Included in delivery of the device: • Brief instructions (Leporello) • CD-ROM with detailed documentation • Sealing plug(s) or sealing screw(s) for the process flanges(s) 1) A B C E H L Y 2) 3) 4) 5) Process connection Female thread ¼-18 NPT with flange connection • Sealing screw opposite process connection 7 B C F Display • Without indicator • Without visible digital indicator (digital indicator } hidden, setting: mA) • With visible digital indication • With customer-specific digital indication (setting as specified, Order code "Y21" or required) Wetted parts materials (stainless steel process flanges) Seal diaphragm Parts of measuring cell Stainless steel Stainless steel Hastelloy Stainless steel Hastelloy Hastelloy Tantalum3) Tantalum Monel3) Monel Gold3) Gold Version as diaphragm seal4) 5) 7MF 4 4 3 5 77777 - 7777 6) 7) - Mounting thread /16-20 UNF to EN 61518 - Mounting thread M10 to DIN 19213 (only for replacement needs) • Venting on side of process flanges2) 2 0 - Mounting thread 7/16-20 UNF to EN 61518 - Mounting thread M10 to DIN 19213 (only for replacement needs) 6 4 8) For oxygen application, add Order code E10. Not suitable for connection of remote seal. Position of the top vent valve in the process flanges (see dimensional drawing). Only together with max. spans 250, 1600, 5000 and 30000 mbar (100.4, 240.9, 2008 inH2O and 435 psi). When the manufacture’s certificate M (calibration certificate) has to be ordered for transmitters with diaphragm seals, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. Whe the acceptance test certificate 3.1 for transmitters with direct-connected diaphragm seals is ordered, this certificate must also be ordered with the corresponding seals. Without cable gland, with blanking plug. With enclosed cable gland EEx ia and blanking plug. Cannot be used together with the following types of protection: "Explosion-proof" and "Intrinsic safety and explosion-proof". Non-wetted parts materials Process flange screws Electronics housing Stainless steel Stainless steel Die-cast aluminium Stainless steel precision casting Version • Standard version • International version, English label inscriptions, documentation in 5 languages on CD Explosion protection • Without • With ATEX, Type of protection: - "Intrinsic safety (EEx ia)" - "Explosion-proof (EEx d)"6) - "Intrinsic safety and explosion-proof enclosure (EEx ia + EEx d)"7) - "n (Zone 2)" (planned) - "Intrinsic safety, explosion-proof enclosure and dust explosion protection (EEx ia + EEx d + Zone 1D/2D)"7) (not for DS III FF) • With FM + CSA, Type of protection: - "Intrinsic safety and explosion-proof (is + xp)"6) 2 3 1 2 A B D P E R NC Siemens FI 01 · 2009 2/113 2 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for differential pressure and flow Selection and Ordering data Order code 2 Selection and Ordering data HART PA Further designs Add "-Z" to Order No. and specify Order code. FF Pressure transmitter with mounting bracket made of: • Steel • Stainless steel A01 A02 9 9 9 9 9 9 O-rings for process flanges (instead of FPM (Viton)) • PTFE (Teflon) • FEP (with silicone core, approved for food) • FFPM (Kalrez, compound 4079) • NBR (Buna N) A20 A21 A22 A23 9 9 9 9 9 9 9 9 9 9 9 9 A30 A31 A40 9 9 9 9 9 Cable sockets for M12 connectors (metal) A50 9 9 9 Rating plate inscription (instead of German) • English • French • Spanish • Italian B11 B12 B13 B14 9 9 9 9 9 9 9 9 9 9 9 9 English rating plate (calibration certificate) B21 Pressure units in inH2O or psi 9 9 9 Quality inspection certificate (Factory cali- C11 bration) to IEC 60770-2 1) 9 9 9 Acceptance test certificate2) To EN 10 204-3.1 C12 9 9 9 Factory certificate To EN 10 204-2.2 C14 9 9 9 "Functional Safety (SIL)" certificate C20 9 "PROFIsafe" certificate and protocol C21 Setting of upper limit of output signal to 22.0 mA D05 9 Manufacturer's declaration acc. to NACE (only together with seal diaphragm made of Hastelloy and stainless steel) D07 9 9 9 Type of protection IP68 (not together with 7D/ Han 8U plug, cable gland Pg 13.5) D12 9 9 9 Digital indicator alongside the input keys (only together with the devices 7MF4433....2-.A.6 or -.A.7-Z, Y21 or Y22 + Y01) D27 9 9 9 Process flange screws made of Monel (max. nominal pressure PN20) D34 9 9 9 Supplied with oval flange set (2 items), PTFE packings and stainles steel screws in thread of process flanges D37 9 9 9 Use in or on zone 1D/2D (only together with type of protection "Intrinsic safety (EEx ia)") E01 9 9 9 Use on zone 0 (only together with type of protection "Intrinsic safety (EEx ia)") E02 9 9 9 TÜV approval to AD/TRD (only together with type of protection "Intrinsic safety (EEx ia)") E06 9 Overfilling safety device for flammable and non-flammable liquids (max. PN 32 (MVWP 464 psi), basic device with type of protection "Intrinsic safety (EEx ia)", to WHG and VbF, not together with measuring cell filling "inert liquid") E08 9 9 9 Plug • Han 7D (metal, gray) • Han 8U (instead of Han 7D) Sealing screws ¼-18 NPT, with valve in mat. of process flanges 2/114 Siemens FI 01 · 2009 Order code HART PA Further designs Add "-Z" to Order No. and specify Order code. FF Oxygen application E10 (max. 120 bar (1740 psi) at 60°C (140 °F) with oxygen measurement and inert liquid) 9 9 9 Explosion-proof "Intrinsic safety" to INMETRO (Brazil) (only for transmitter 7MF4...-.....-.B..) E25 9 9 9 Explosion-proof "Intrinsic safety" to NEPSI E55 (China) (only for transmitter 7MF4...-.....-.B..) 9 9 9 Explosion protection "Explosion-proof" to E56 NEPSI (China) (only for transmitter 7MF4...-.....-.D..) 9 9 9 Explosion-proof "Zone 2" to NEPSI (China) E57 (only for transmitter 7MF4...-.....-.E..) 9 9 9 Interchanging of process connection side H01 9 9 9 Vent on side for gas measurements H02 9 9 9 Stainless steel process flanges for vertical H03 differential pressure lines (not together with K01, K02 and K04)3) 9 9 9 9 9 9 9 9 9 9 9 9 Process flange • Hastelloy K01 • Monel K02 • Stainless steel with PVDF insert K04 max. PN 10 (MWP 145 psi), max. temperature of medium 90 °C (194 °F) For ½-14 NPT inner process connection on the side in the middle of the process flange, vent valve not possible 9 = available 1) 9 2) 3) When the manufacture’s certificate M (calibration certificate) has to be ordered for transmitters with diaphragm seals, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. Whe the acceptance test certificate 3.1 for transmitters with direct-connected diaphragm seals is ordered, this certificate must also be ordered with the corresponding seals. Not suitable for connection of remote seal © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for differential pressure and flow Selection and Ordering data Order code HART PA Additional data Add "-Z" to Order No. and specify Order code. Measuring range to be set Specify in plain text: • With linear characteristic (max. 5 digits): Y01: ... up to ... mbar, bar, kPa, MPa, psi • With square-rooted characteristic (max. 5 digits): Y02: ... up to ... mbar, bar, kPa, MPa, psi FF 2 Y01 9 Y02 9 Measuring point number (TAG No.) Y15 Max. 16 char., specify in plain text: Y15: ....... 9 9 9 Measuring point text Y16 Max. 27 char., specify in plain text: Y16: ....... 9 9 9 Entry of HART address (TAG) Max. 8 char., specify in plain text: Y17: ....... Y17 9 Setting of pressure indicator in pressure Y21 units Specify in plain text (standard setting: mA): Y21: mbar, bar, kPa, MPa, psi, ... Note: The following pressure units can be selected: bar, mbar, mm H2O*), inH2O*), ftH2O*), mmHG, inHG, psi, Pa, kPa, MPa, g/cm2, kg/cm2, Torr, ATM oder % *) ref. temperature 20 °C 9 9 9 Setting of pressure indicator in non-pressure units Specify in plain text: Y22: ..... up to ..... l/min, m3/h, m, USgpm, ... (specification of measuring range in pressure units "Y01" or "Y02" is essential, unit with max. 5 characters) Y221) + Y01 or Y02 Preset bus address (possible between 1 and 126) Specify in plain text: Y25: ..................... Y25 9 9 Only "Y01", "Y21", "Y22", "Y25" and "D05" can be factory preset 9 = available 1) Not together with over-filling safety device for flammable and non-flammable liquids (Order code "E08") Siemens FI 01 · 2009 2/115 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for differential pressure and flow 2 Selection and Ordering data Order No. Selection and Ordering data Order No. SITRANS P pressure transmitters for differential pressure and flow, Series DS III HART PN 420 (MWP 6092 psi) 7MF 4 5 3 3 - SITRANS P pressure transmitters for differential pressure and flow, Series DS III HART PN 420 (MWP 6092 psi) 77777 - 7777 Measuring cell filling Silicone oil Measuring cell cleaning Standard Span 2.5 ... 250 mbar 6 ... 600 mbar 16 ... 1600 mbar 50 ... 5000 mbar 0.3 ... 30 bar (1.004 ... 100.4 inH2O) (2.409 ... 240.9 inH2O) (6.424 ... 642.4 inH2O) (20.08 ... 2008 inH2O) (4.35 ... 435 psi) 77777 - 7777 Display • Without indicator • Without visible digital indicator (digital indicator } hidden, setting: mA) • With visible digital indication • With customer-specific digital indication (setting as specified, Order code "Y21" or required) 1 D E F G H Stainless steel Stainless steel Gold Process connection Female thread ¼-18 NPT with flange connection • Sealing screw opposite process connection - Mounting thread 7/16-20 UNF to EN 61518 - Mounting thread M12 to DIN 19213 (only for replacement needs) • Venting on side of process flanges. Position of the top vent valve in the process flanges (see dimensional drawing). - Mounting thread 7/16-20 UNF to EN 61518 - Mounting thread M12 to DIN 19213 (only for replacement needs) Die-cast aluminium Stainless steel precision casting2) Version • Standard version • International version, English label inscriptions, documentation in 5 languages on CD Explosion protection • Without • With ATEX, Type of protection: - "Intrinsic safety (EEx ia)" - "Explosion-proof (EEx d)"3) - "Intrinsic safety and explosion-proof enclosure (EEx ia + EEx d)"4) - "Ex nA/nL (zone 2)" - "Intrinsic safety, explosion-proof enclosure and dust explosion protection (EEx ia + EEx d + Zone 1D/2D)"4) • With FM + CSA, Type of protection: - "Intrinsic safety and explosion-proof (is + xp)"3), max PN 360 Electrical connection / cable entry • Screwed gland Pg 13.55) • Screwed gland M20x1.5 • Screwed gland ½-14 NPT • Han 7D plug (plastic housing) incl. mating connector5) • M12 connectors (metal)6) 2/116 Siemens FI 01 · 2009 6 7 Factory-mounting of shut-off valves and valve manifolds see page 2/142. Scope of delivery: Pressure transmitter as ordered (Instruction Manual is extra ordering item) A B L 1) 2) 3) 4) 5) 3 1 6) 7 5 Non-wetted parts materials Process flange screws Electronics housing Stainless steel Stainless steel 0 1 Power supply units see "SITRANS I power supply units and isolation amplifiers". Wetted parts materials (stainless steel process flanges) Seal diaphragm Parts of measuring cell Stainless steel Hastelloy Gold1) 7MF 4 5 3 3 - 2 3 1 2 A B D P E R NC A B C D F Not together with max. span 600 mbar (240.9 inH2O) Not together with Electrical connection „Screwed gland Pg 13.5“ and „Han7D plug“. Without cable gland, with blanking plug With enclosed cable gland EEx ia and blanking plug Not together with type of protection "Explosion-proof" and and type of protection "Ex nA". Cannot be used together with the following types of protection: "Explosion-proof" and "Intrinsic safety and explosion-proof". © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for differential pressure and flow Selection and Ordering data Order No. Order No. Selection and Ordering data SITRANS P pressure transmitters for differential pressure and flow, Series DS III HART PN 420 (MWP 6092 psi) SITRANS P pressure transmitters for differential pressure and flow, Series DS III HART PN 420 (MWP 6092 psi) DS III PA (PROFIBUS PA) series 7MF 4 5 3 4 - DS III PA (PROFIBUS PA) series 7MF 4 5 3 4 - DS III FF series (FOUNDATION Fieldbus) 7MF 4 5 3 5 - DS III FF series (FOUNDATION Fieldbus) 7MF 4 5 3 5 - 1 7777 - 7777 Nominal measuring range 250 mbar (100.4 inH2O) 600 mbar (240.9 inH2O) 1600 mbar (642.4 inH2O) 5 bar (2008 inH2O) 30 bar (435 psi) Display • Without indicator • Without visible digital indicator (digital indicator } hidden, setting: mA) • With visible digital indicator • With customer-specific digital indicator (setting as specified, Order code "Y21" or required) D E F G H Wetted parts materials (stainless steel process flanges) Seal diaphragm Parts of measuring cell Stainless steel Hastelloy Gold1) Stainless steel Stainless steel Gold Process connection Female thread ¼-18 NPT with flange connection • Sealing screw opposite process connection - Mounting thread 7/16-20 UNF to EN 61518 - Mounting thread M12 to DIN 19213 (only for replacement needs) • Venting on side of process flanges. Position of the top vent valve in the process flanges (see dimensional drawing). - Mounting thread 7/16-20 UNF to EN 61518 - Mounting thread M12 to DIN 19213 (only for replacement needs) 1 7777 - 7777 0 1 6 7 Factory-mounting of shut-off valves and valve manifolds see page 2/142. Included in delivery of the device: • Brief instructions (Leporello) • CD-ROM with detailed documentation • Sealing plug(s) or sealing screw(s) for the process flanges(s) A B L 1) 2) 3) 4) 3 1 Not together with max. span 600 mbar (240.9 inH2O) Without cable gland, with blanking plug. With enclosed cable gland EEx ia and blanking plug. Not together with types of protection "Explosion-proof" and "Intrinsic safety and explosion-proof" 7 5 Non-wetted parts materials Process flange screws Electronics housing Stainless steel Stainless steel Die-cast aluminium Stainless steel precision casting Version • Standard version • International version, English label inscriptions, documentation in 5 languages on CD Explosion protection • Without • With ATEX, Type of protection: - "Intrinsic safety (EEx ia)" - "Explosion-proof (EEx d)"2) - "Intrinsic safety and explosion-proof enclosure (EEx ia + EEx d)"3) - "Ex nA/nL (zone 2)" - "Intrinsic safety, explosion-proof enclosure and dust explosion protection (EEx ia + EEx d + Zone 1D/2D)"3) (not for DS III FF) • With FM + CSA, Type of protection: - "Intrinsic safety and explosion-proof (is + xp)"2), max PN 360 Electrical connection / cable entry • Screwed gland M20x1.5 • Screwed gland ½-14 NPT • Plug M12 incl. mating connector4) 2 3 1 2 A B D P E R NC B C F Siemens FI 01 · 2009 2/117 2 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for differential pressure and flow Selection and Ordering data Order code 2 Selection and Ordering data HART PA Further designs FF Order code HART PA Further designs FF Add "-Z" to Order No. and specify Order code. Add "-Z" to Order No. and specify Order code. Pressure transmitter with mounting bracket made of: • Steel • Stainless steel 9 9 9 A01 A02 9 9 9 9 9 9 Explosion protection "Explosion-proof" to E56 NEPSI (China) (only for transmitter 7MF4...-.....-.D..) Explosion-proof "Zone 2" to NEPSI (China) E57 (only for transmitter 7MF4...-.....-.E..) 9 9 9 O-rings for process flanges (instead of FPM (Viton)) • PTFE (Teflon) • FEP (with silicone core, approved for food) • FFPM (Kalrez, compound 4079) • NBR (Buna N) A20 A21 A22 A23 9 9 9 9 9 9 9 9 9 9 9 9 Interchanging of process connection side H01 9 9 9 Stainless steel process flanges for vertical differential pressure lines H03 9 9 9 Plug • Han 7D (metal, gray) • Han 8U (instead of Han 7D) A30 A31 9 9 Sealing screws ¼-18 NPT, with valve in material of process flanges A40 9 Y01 9 Cable sockets for M12 connectors (metal) A50 9 9 9 Y02 9 Rating plate inscription (instead of German) • English • French • Spanish • Italian 9 9 9 9 9 9 9 9 9 9 9 9 Measuring point number (TAG No.) Max. 16 characters, specify in plain text: Y15: ........................................... Y15 B11 B12 B13 B14 9 9 9 Y16 9 9 9 B21 9 9 9 Measuring point text Max. 27 characters, specify in plain text: Y16: ........................................... 9 9 9 9 Entry of HART address (TAG) Max. 8 characters, specify in plain text: Y17: ........................................... Y17 Quality inspection certificate (Factory cali- C11 bration) to IEC 60770-2 Acceptance test certificate To EN 10204-3.1 C12 9 9 9 9 9 9 Factory certificate To EN 10204-2.2 C14 9 9 9 "Functional Safety (SIL)" certificate C20 9 "PROFIsafe" certificate and protocol C21 Setting of upper limit of output signal to 22.0 mA D05 9 Setting of pressure indication in pressure Y21 units Specify in plain text (standard setting: mA): Y21: mbar, bar, kPa, MPa, psi, ... Note: The following pressure units can be selected: bar, mbar, mm H2O*), inH2O*), ftH2O*), mmHG, inHG, psi, Pa, kPa, MPa, g/cm2, kg/cm2, Torr, ATM or % *) ref. temperature 20 °C Manufacturer's declaration acc. to NACE (only together with seal diaphragm made of Hastelloy and stainless steel) D07 9 9 9 9 Type of protection IP68 (not together with Han 7D / Han 8U plug, Pg 13.5 screwed gland) D12 9 9 9 Setting of pressure indication in Y22 + non-pressure units Y01 or Y02 Specify in plain text: Y22: ..... up to ..... l/min, m3/h, m, USgpm, ... (specification of measuring range in pressure units "Y01" or "Y02" is essential, unit with max. 5 characters) Digital indicator alongside the input keys (only together with the devices 7MF4533....2-.A.6 or -.A.7-Z, Y21 or Y22 + Y01) D27 9 9 9 Use in or on zone 1D/2D (only together with type of protection "Intrinsic safety (EEx ia)") E01 9 9 9 Use on zone 0 (only together with type of protection "Intrinsic safety (EEx ia)") E02 9 9 9 Explosion-proof "Intrinsic safety" to INMETRO (Brazil) (only for transmitter 7MF4...-.....-.B..) E25 9 9 9 Explosion-proof "Intrinsic safety" to NEPSI (China) (only for transmitter 7MF4...-.....-.B..) E55 9 9 9 English rating plate Pressure units in inH2O or psi 2/118 Siemens FI 01 · 2009 Additional data Add "-Z" to Order No. and specify Order code. 9 9 9 Measuring range to be set Specify in plain text: • With linear characteristic (max. 5 digits): Y01: ... up to ... mbar, bar, kPa, MPa, psi • With square-rooted characteristic (max. 5 digits): Y02: ... up to ... mbar, bar, kPa, MPa, psi Preset bus address (possible between 1 and 126) Specify in plain text: Y25: ..................... Y25 Only "Y01", "Y21", "Y22", "Y25" and "D05" can be factory preset 9 = available 9 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for differential pressure and flow ■ Dimensional drawings 3 approx. 261 (10.3) 9 134 (5.27) 1 + Space for rotation of housing 10 8 7 11 ø 50 ... 60 (1.97 ... 2.36) approx. 96 (3.78) 52 (2.05) 3 72 (2.83) 105 (4.1) 1 2 3 4 5 6 7 8 9 10 11 Process connection: ¼-18 NPT (EN 61518) Blanking plug Electrical connection: - screwed gland Pg 13,5 (adapter) 2) 3), - screwed gland M20x1,5 3), - screwed gland ½-14 NPT or - Han 7D/ Han 8U plug 2) 3) Terminal side Electronics side, digital display (longer overall length for cover with window) Protective cover over keys Mounting bracket (option) Sealing screw with valve (option) Screw cover - safety bracket (only for type of protection "Explosion-proof enclosure", not shown in the drawing) Lateral venting for liquid measurement (Standard) Lateral venting for gas measurement (suffix H02) 96 (3.8) 117 (4.6) 1) 4 69 (2.7) 90 (3.6)4) 2 2 6 50 (1.97) Ø 80 (3.15) 5 1) 100 (3.94) approx. 30 (1.2) 5) 51 (2.0) 198 (7.8) 144 (5.67) 20 (0.8) 15 (0.6) 68 (2.7) 120 (4.7) 1) 2) 3) 4) 5) Allow approx. 20 mm (0.79 inch) thread length to permit unscrewing Not with type of protection "explosion-proof enclosure" Not with type of protection "FM + CSA [is + xp]" 92 mm (3.62 inch) for minimum distance to permit rotation with indicator 45 mm (1.8 inch) for Pg 13,5 with adapter SITRANS P pressure transmitters, DS III HART series for differential pressure and flow, dimensions in mm (inch) Siemens FI 01 · 2009 2/119 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for differential pressure and flow approx. 30 (1.2) 2 6 approx. 261 (10.3) 9 1 + Space for rotation of housing 10 8 7 52 (2.05) ø 50 ... 60 (1.97 ... 2.36) 11 96 (3.8) 1) 4 3 198 (7.8) 117 (4.6) Ø 80 (3.15) 5 1) 100 (3.94) 50 (1.97) 51 (2.0) 69 (2.7) 90 (3.6)2) 134 (5.27) 2 144 (5.67) 20 (0.8) 15 (0.6) 72 (2.83) 105 (4.1) 1 2 3 4 5 6 7 8 9 10 11 Process connection: ¼-18 NPT (EN 61518) Blanking plug Electrical connection: - screwed gland M20x1,5 4), - screwed gland ½-14 NPT or - PROFIBUS plug M12 3) 4) Terminal side Electronic side, digital display (longer overall length for cover with window) Protective cover over keys Mounting bracket (option) Sealing screw with valve (option) Screw cover safety bracket (only for explosion-proof enclosure, not shown in the drawing) Lateral venting for liquid measurement (Standard) Lateral venting for gas measurement (suffix H02) 68 (2.7) 120 (4.7) 1) 2) 3) 4) Allow approx. 20 mm (0.79 inch) thread length in addition 92 mm (3.62 inch) for minimum distance to permit rotation with indicator Not with type of protection "explosion-proof enclosure" Not with type of protection "FM + CSA" SITRANS P pressure transmitters, DS III PA and FF series for differential pressure and flow, dimensions in mm (inch) 2/120 Siemens FI 01 · 2009 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for differential pressure and flow 144 (5.67) 3 6 2 3 9 approx. 85 (3.35)6) Space for rotation of housing 90 (3.6)4) 100 (3.94) 2 4 1) 5 1) approx. 30 (1.18)8) 8 + approx. 217 (8.54)7) Ø 80 (3.15) 74 (2.9) approx. 96 (3.78) 50 (1.97) 51 (2.0) 20 (0.8) 15 (0.6) 8 1 67 (2.64)5) 1 2 3 4 5 6 7 8 9 Process connection: ¼-18 NPT (EN 61518) Blanking plug Electrical connection: - screwed gland Pg 13,5 (adapter) 2) 3), - screwed gland M20x1,5 3), - screwed gland ½-14 NPT or - Han 7D/ Han 8U plug 2) 3) Terminal side Electronics side, digital display (longer overall length for cover with window) Protective cover over keys Mounting bracket (option) Sealing screw with valve (option) Screw cover - safety bracket (only for type of protection "Explosion-proof enclosure", not shown in the drawing) approx. 84,6 (3.33) 1) 2) 3) 4) 5) 6) 7) 8) Allow approx. 20 mm (0.79 inch) thread length to permit unscrewing Not with type of protection "explosion-proof enclosure" Not with type of protection "FM + CSA [is + xp]" 92 mm (3.6 inch) for minimum distance to permit rotation with indicator 74 mm (2.9 inch) for PN ³ 420 (MWP ³ 6092 psi) 91 mm (3.6 inch) for PN ³ 420 (MWP ³ 6092 psi) 219 mm (8.62 inch) for PN ³ 420 (MWP ³ 6092 psi) 45 mm (1.8 inch) for Pg 13,5 with adapter SITRANS P pressure transmitters, DS III HART series for differential pressure and flow, with process covers for vertical differential pressure lines, option „H03“, dimensions in mm (inch) Siemens FI 01 · 2009 2/121 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for differential pressure and flow 144 (5.67) 90 (3.6)4) 6 50 (1.97) 2 9 approx. 85 (3.35)6) 5 1) 100 (3.94) 3 4 1) Space for rotation of housing 2 diam. 80 (3.15) 74 (2.9) approx 30 (1.18)6) 20 (0.8) 51 (2.0) 8 + approx. 217 (8.54)7) 15 (0.6) 8 1 67 (2.64)5) 1 2 3 4 5 6 7 8 9 Process connection ¼-18 NPT (EN 61 518) Blanking plug Electrical connection: screwed gland M20x1.5 3), screwed gland ½-14 NPT or PROFIBUS plug M12 2) 3) Terminal side Electronics side, digital display (longer overall length for cover with window) Protective cover over keys Mounting bracket (option) Sealing screw with valve (option) Screw cover safety bracket (only for explosion-proof enclosure, not shown in the drawing) approx. 84,6 (3.33) 1) 2) 3) 4) 5) 6) 7) Allow approx. 20 mm (0.79 inch) thread length in addition Not with type protection "explosion-proof enclosure" Not with type protection "FM + CSA [is + xp]" 92 mm (3.6 inch) for minimum distance to permit rotation without indicator 74 mm (2.9 inch) for PN ³ 420 (MWP ³ 6092 psi) 91 mm (3.6 inch) for PN ³ 420 (MWP ³ 6092 psi) 219 mm (8.62 inch) for PN ³ 420 (MWP ³ 6092 psi) SITRANS P pressure transmitters, DS III PA and FF series for differential pressure and flow, with process covers for vertical differential pressure lines, option „H03“, dimensions in mm (inch) SITRANS P pressure transmitters, DS III series for differential pressure and flow, with process covers for vertical differential pressure lines 2/122 Siemens FI 01 · 2009 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for differential pressure and flow 2 90 (3.6) SITRANS P pressure transmitters, DS III FF series for differential pressure and flow, with digital indicator beside control keys, for vertical differential pressure lines, option „D27“, dimensions in mm (inch) SITRANS P pressure transmitters, DS III series for differential pressure and flow, with digital indicator beside control keys Siemens FI 01 · 2009 2/123 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for level ■ Technical specifications SITRANS P, DS III series for level HART 2 PROFIBUS PA or FOUNDATION Fieldbus Input Measured variable Level Spans (infinitely adjustable) or nominal measuring range and max. permissible working pressure Span Maximum working pressure Nominal measuring range Maximum working pressure 25 ... 250 mbar g (0.36 ... 3.63 psi g) See "Mounting flange" 250 mbar g (3.63 psi g) See "Mounting flange" 25 ... 600 mbar g (0.36 ... 8.7 psi g) See "Mounting flange" 600 mbar g (8.7 psi g) See "Mounting flange" 53 ... 1600 mbar g (0.77 ... 23.2 psi g) See "Mounting flange" 1600 mbar g (23.2 psi g) See "Mounting flange" 160 ... 5000 mbar g (2.32 ... 72.5 psi g) See "Mounting flange" 5000 mbar g (72.5 psi g) See "Mounting flange" Lower measuring limit • Measuring cell with silicone oil filling -100% of max. span or 30 mbar (0.435 psi a), depending on mounting flange Upper measuring limit 100% of max. span 100% of the max. nominal measuring range Output signal 4 ... 20 mA Digital PROFIBUS PA or FOUNDATION Fieldbus signal • Lower limit (infinitely adjustable) 3.55 mA, factory preset to 3.84 mA - • Upper limit (infinitely adjustable) 23 mA, factory preset to 20.5 mA or optionally set to 22.0 mA - • Without HART communication RB ≤ (UH - 10.5 V)/0.023 A in Ω, UH : Power supply in V - • With HART communication RB = 230 ... 500 Ω (SIMATIC PDM) or RB = 230 ... 1100 Ω (HART Communicator) - Physical bus - IEC 61158-2 With polarity reversal protection - Yes Accuracy To EN 60770-1 Output Load Reference conditions Increasing characteristic, start-of-scale value 0 bar, stainless steel seal diaphragm, silicone oil fill(All error data refer always refer to the set span) ing, room temperature 25 °C (77 °F)) r: Span ratio (r = max. span / set span) Error in measurement and fixed-point setting (including hysteresis and repeatability) ≤ 0.075% • Linear characteristic - r ≤ 10 ≤ 0.15% - 10 < r ≤ 30 ≤ 0.3% - 30 < r ≤ 100 ≤ (0.0075 ⋅ r + 0.075)% Long-term drift (temperature change ±30 °C (±54 °F)) ≤ (0.25 ⋅ r)% every 5 years static pressure max. 70 bar g (1015 psi g) ≤ (0.25% every 5 years static pressure max. 70 bar g (1015 psi g) - 250 mbar (3.63 psi) measuring cell ≤ (0.5 ⋅ r + 0.2)% (0.4 instead of 0.2 with 10 < r ≤ 30) ≤ 0,7% - 600 mbar (8.7 psi) measuring cell ≤ (0.3 ⋅ r + 0.2)% (0.4 instead of 0.2 with 10 < r ≤ 30) ≤ 0,5% - 1600 and 5000 mbar (23.2 and 72.5 psi) measuring cells ≤ (0.25 ⋅ r + 0.2)% (0.4 instead of 0.2 with 10 < r ≤ 0,45% ≤ 30) Influence of ambient temperature • at -10 ... +60 °C (14 ... 140 °F) • at -40 ... -10 °C and +60 ... +85 °C (-40 ... +14 °F and 140 ... 185 °F) - 250 mbar (3.63 psi) measuring cell ≤ (0.25 ⋅ r +0.15)%/10 K double values with 10 < r ≤ 30 ≤ 0.4%/10 K - 600 mbar (8.7 psi) measuring cell ≤ (0.15 ⋅ r +0.15)%/10 K double values with 10 < r ≤ 30 ≤ 0.3%/10 K - 1600 and 5000 mbar (23.2 and 72.5 psi) measuring cells ≤ (0.12 ⋅ r +0.15)%/10 K double values with 10 < r ≤ 30 ≤ 0.27%/10 K 2/124 Siemens FI 01 · 2009 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for level SITRANS P, DS III series for level HART PROFIBUS PA or FOUNDATION Fieldbus - 250 mbar (3.63 psi) measuring cell ≤ (0.3 ⋅ r)% per nominal pressure ≤ 0.3% per nominal pressure - 600 mbar (8.7 psi) measuring cell ≤ (0.15 ⋅ r)% per nominal pressure ≤ 0.15% per nominal pressure - 1600 and 5000 mbar (23.2 and 72.5 psi) measuring cells ≤ (0.1 ⋅ r)% per nominal pressure ≤ 0.1% per nominal pressure • on the span ≤ (0.1 ⋅ r)% per nominal pressure ≤ 0.1% per nominal pressure Measured Value Resolution - 3 ⋅ 10-5 of nominal measuring range Influence of static pressure • on the zero point 2 Rated operating conditions Degree of protection (to EN 60529) IP65 Process temperature Note: Always take into account assignment of max. permissible working temperature to max. permissible working pressure of the respective flange connection! • Measuring cell with silicone oil filling -40 ... +100 °C (-40 ... +212 °F) - High-pressure side pabs ≥ 1bar: -40 ... +175 °C (-40 ... +347 °F) pabs ≥ 1bar: -40 ... +80 °C (-40 ... +176 °F) - Low-pressure side -40 ... +100 °C (-40 ... +212 °F) -20 ... +60 °C (-4 ... +140 °F) in conjunction with dust explosion protection Ambient conditions • Ambient temperature - Digital indicators -30 ... +85 °C (-22 ... +185 °F) • Storage temperature -50 ... +85 °C (-58 ... +185 °F) • Climatic class - Condensation Permissible • Electromagnetic compatibility - Emitted interference and interference immu- To EN 61326 and NAMUR NE 21 nity Design Weight (without options) • To EN (pressure transmitter with mounting flange, without tube) ≈ 11 ... 13 kg (≈ 24.2 ... 28.7 lb) • To ASME (pressure transmitter with mounting flange, without tube) ≈ 11 ... 18 kg (≈ 24.2 ... 39.7 lb) Wetted parts materials Poor in copper die-cast aluminium, GD-AlSi12 or stainless steel precision casting, mat. No. 1.4408 Housing material High-pressure side • Seal diaphragm of mounting flange Stainless steel, mat. No. 1.4404/316L, Monel, mat. No. 2.4360, Hastelloy B2, mat. No. 2.4617, Hastelloy C276, mat. No. 2.4819, Hastelloy C4, mat. No. 2.4610, tantalum, PTFE, ECTFE Measuring cell filling Silicone oil Process connection • High-pressure side Flange to EN and ASME • Low-pressure side Female thread ¼-18 NPT and flange connection with mounting thread M10 to DIN 19213 or 7/ -20 UNF to EN 61518 16 Supplied through bus Power supply UH Terminal voltage on transmitter 10.5 ... 45 V DC 10.5 ... 30 V DC in intrinsically-safe mode - Separate 24 V power supply necessary - No Bus voltage • Not Ex - 9 ... 32 V • With intrinsically-safe operation - 9 ... 24 V Current consumption • Basic current (max.) - 12.5 mA • Startup current ≤ basic current - Yes • Max. current in event of fault - 15.5 mA Fault disconnection electronics (FDE) available - Yes Siemens FI 01 · 2009 2/125 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for level SITRANS P, DS III series for level HART PROFIBUS PA or FOUNDATION Fieldbus Certificate and approvals 2 Classification according to pressure equipment For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of Article 3, directive (DRGL 97/23/EC) paragraph 3 (sound engineering practice) Explosion protection • Intrinsic safety "i" PTB 99 ATEX 2122 - Identification Ex II 1/2 G EEx ia/ib IIB/IIC T6 - Permissible ambient temperature -40 ... +85 °C (-40 ... +185 °F) temperature class T4; -40 ... +70 °C (-40 ... +158 °F) temperature class T5; -40 ... +60 °C (-40 ... +140 °F) temperature class T6 - Connection To certified intrinsically-safe circuits with maximum values: Ui = 30 V, Ii = 100 mA, Pi = 750 mW; Ri = 300 Ω FISCO supply unit: Uo = 17.5 V, Io = 380 mA, Po = 5.32 W Linear barrier: Uo = 24 V, Io = 250 mA, Po = 1.2 W L i = 0.4 mH, Ci = 6 nF L i = 7 μH, Ci = 1.1 nF - Effective internal inductance/capacitance • Explosion-proof "d" PTB 99 ATEX 1160 - Identification Ex II 1/2 G EEx d IIC T4/T6 - Permissible ambient temperature -40 ... +85 °C (-40 ... +185 °F) temperature class T4; -40 ... +60 °C (-40 ... +140 °F) temperature class T6 - Connection • Dust explosion protection for zone 20 To circuits with values: UH = 10.5 ... 45 V DC To circuits with values: UH = 9 ... 32 V DC PTB 01 ATEX 2055 - Identification Ex II 1 D IP65 T 120 °C Ex II 1/2 D IP65 T 120 °C - Permissible ambient temperature -40 ... +85 °C (-40 ... +185 °F) - Max.surface temperature 120 °C (248 °F) - Connection To certified intrinsically-safe circuits with maximum values: Ui = 30 V, Ii = 100 mA, Pi = 750 mW, Ri = 300 Ω FISCO supply unit: Uo = 17.5 V, Io = 380 mA, Po = 5.32 W Linear barrier: Uo = 24 V, Io = 250 mA, Po = 1.2 W - Effective internal inductance/capacitance L i = 0.4 mH, Ci = 6 nF L i = 7 μH, Ci = 1.1 nF • Dust explosion protection for zone 21/22 PTB 01 ATEX 2055 - Identification Ex II 2 D IP65 T 120 °C - Connection To circuits with values: UH = 10.5 ... 45 V DC; Pmax = 1.2 W • Type of protection "n" (zone 2) - Identification • Explosion protection to FM - Identification (XP/DIP) or (IS); (NI) • Explosion protection to CSA - Identification (XP/DIP) or (IS) 2/126 Siemens FI 01 · 2009 To circuits with values: UH = 9 ... 32 V DC; Pmax = 1.2 W TÜV 01 ATEX 1696 X Planned Ex II 3 G EEx nA L IIC T4/T5/T6 - Certificate of Compliance 3008490 CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; CL I, ZN 0/1 AEx ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III Certificate of Compliance 1153651 CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; Ex ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for level HART communication HART communication Communication FOUNDATION Fieldbus 230 ... 1100 Ω Protocol HART Version 5.x Software for computer SIMATIC PDM Function blocks 3 function blocks analog input, 1 function block PID • Analog input PROFIBUS PA communication - Adaptation to customer-specif- Yes, linearly rising or falling charic process variables acteristic Simultaneous communication with 4 master class 2 (max.) - Electrical damping T63 , adjust- 0 ... 100 s able The address can be set using - Simulation function Output/input (can be locked within the device with a bridge) - Failure mode Can be parameterized (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively - Square-rooted characteristic for flow measurement Yes Configuration tool or local operation (standard setting address 126) Cyclic data usage • Output byte 5 (one measuring value) or 10 (two measuring values) • Input byte 0, 1, or 2 (register operating mode and reset function for metering) Internal preprocessing Device profile Function blocks PROFIBUS PA Profile for Process Control Devices Version 3.0, Class B • PID • Physical block 1 Resource block 2 Transducer blocks 1 transducer block Pressure with calibration, 1 transducer block LCD • Analog input - Adaptation to customer-specif- Yes, linearly rising or falling charic process variables acteristic - Electrical damping T63 , adjust- 0 ... 100 s able - Simulation function Input /Output - Failure mode Can be parameterized (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively • Register (totalizer) - Failure mode - Limit monitoring Can be reset, preset, optional direction of counting, simulation function of register output Can be parameterized (summation with last good value, continuous summation, summation with incorrect value) One upper and lower warning limit and one alarm limit respectively • Physical block 1 Transducer blocks 2 Standard FF function block • Pressure transducer block - Can be calibrated by applying Yes two pressures - Monitoring of sensor limits Yes - Simulation function: Measured Constant value or over parameterpressure value, sensor temper- izable ramp function ature and electronics temperature Mounting flange Nom. diam. Nom. press. • To EN 1092-1 - DN 80 PN 40 - DN 100 PN16, PN40 • To ASME B16.5 - 3 inch Class 150, class 300 - 4 inch Class 150, class 300 • Pressure transducer block - Can be calibrated by applying Yes two pressures - Monitoring of sensor limits Yes - Specification of a container characteristic with Max. 30 nodes - Square-rooted characteristic for flow measurement Yes - Gradual volume suppression and implementation point of square-root extraction Parameterizable - Simulation function for meaConstant value or over parametersured pressure value and sen- izable ramp function sor temperature Siemens FI 01 · 2009 2/127 2 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for level 2 Selection and Ordering data Order No. 1) SITRANS P pressure transmitters for level series DS III HART 7MF 4 6 3 3 - 2) 77 Y77 - 7777 3) Measuring cell filling Silicone oil Measuring cell cleaning Standard Span 25 ... 250 mbar 25 ... 600 mbar 53 ... 1600 mbar 0.16 ... 5 bar (0.363 ... 3.63 psi) (0.363 ... 8.70 psi) (0.77 ... 23.2 psi) (2.32 ... 72.5 psi) 4) 5) 1 Process connection of low-pressure side Female thread ¼-18 NPT with flange connection • Mounting thread 7/16-20 UNF to EN 61518 • Mounting thread M10 to DIN 19213 (only for replacement needs) D E F G 2 0 Non-wetted parts materials Process flange screws Electronics housing Stainless steel Stainless steel Die-cast aluminium Stainless steel precision casting1) 2 3 Version • Standard version • International version, English label inscriptions, documentation in 5 languages on CD Explosion protection • Without • With ATEX, Type of protection: - "Intrinsic safety (EEx ia)" - "Explosion-proof (EEx d)"2) - "Intrinsic safety and explosion-proof enclosure (EEx ia + EEx d)"3) - "Ex nA/nL (zone 2)" - "Intrinsic safety, explosion-proof enclosure and dust explosion protection (EEx ia + EEx d + Zone 1D/2D)"3) • With FM + CSA, Type of protection: - "Intrinsic safety and explosion-proof (is + xp)"1) Electrical connection / cable entry • Screwed gland Pg 13.54) • Screwed gland M20x1.5 • Screwed gland ½-14 NPT • Han 7D plug (plastic housing) incl. mating connector4) • M12 connectors (metal)5) 1 2 A B D P E R NC A B C D F Display • Without indicator • Without visible digital indicator (digital indicator } hidden, setting: mA) • With visible digital indication • With customer-specific digital indication (setting as specified, Order code "Y21" or required) Ordering information: 1st order item: Pressure transmitter 7MF4633-... 2nd order item: Mounting flange 7MF4912-3... Ordering example: Item line 1: 7MF4633-1EY20-1AA1-Z B line: Y01 C line: Y01: 80 to 143 mbar (1.16 to 2.1 psi) Item line 2: 7MF4912-3GE01 Power supply units see "SITRANS I power supply units and isolation amplifiers". Included in delivery of the device: • Brief instructions (Leporello) • CD-ROM with detailed documentation • Sealing plug(s) or sealing screw(s) for the process flanges(s) 2/128 Siemens FI 01 · 2009 0 1 6 7 Not together with Electrical connection „Screwed gland Pg 13.5“ and „Han7D plug“. Without cable gland, with blanking plug. With enclosed cable gland EEx ia and blanking plug. Not together with type of protection "Explosion-proof" and type of protection "Ex nA". Not together with types of protection "Explosion-proof" or "Intrinsic safety and explosion-proof" © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for level Selection and Ordering data Order No. 7MF 4 6 3 4 - DS III FF series (FOUNDATION Fieldbus) 7MF 4 6 3 5 - Die-cast aluminium Stainless steel precision casting Display • Without indicator • Without visible digital indicator (digital indicator } hidden, setting: mA) • With visible digital indication • With customer-specific digital indication (setting as specified, Order code "Y21" or required) Sealing screws ¼-18 NPT, with valve in material of process flanges A40 Cable sockets for M12 connectors (metal) Rating plate inscription (instead of German) • English • French • Spanish • Italian 9 9 9 B11 B12 B13 B14 9 9 9 9 9 9 9 9 9 9 9 9 B21 9 9 9 A Quality inspection certificate (Factory cali- C11 bration) to IEC 60770-2 9 9 9 B D P Acceptance test certificate To EN 10204-3.1 C12 9 9 9 Factory certificate To EN 10204-2.2 C14 9 9 9 "Functional Safety (SIL)" certificate C20 9 "PROFIsafe" certificate and protocol C21 Setting of upper limit of output signal to 22.0 mA D05 9 Type of protection IP68 (not together with PROFIBUS plug M12) D12 9 9 9 Supplied with oval flange (1 item), PTFE packing and stainless steel screws in thread of process flange D37 9 9 9 0 1 Use on zone 1D / 2D (only together with type of protection "Intrinsic safety (EEx ia)") E01 9 9 9 6 7 Use on zone 0 (only together with type of protection "Intrinsic safety (EEx ia)") E02 9 9 9 Overfilling safety device for flammable and non-flammable liquids (max. PN 32 (MVWP 464 psi), basic device with type of protection "Intrinsic safety (EEx ia)") E08 9 9 Explosion-proof "Intrinsic safety" to INMETRO (Brazil) (only for transmitter 7MF4...-.....-.B..) E25 9 9 9 Explosion-proof "Intrinsic safety" to NEPSI (China) (only for transmitter 7MF4...-.....-.B..) E55 9 9 9 Explosion protection "Explosion-proof" to E56 NEPSI (China) (only for transmitter 7MF4...-.....-.D..) 9 9 9 Explosion-proof "Zone 2" to NEPSI (China) E57 (only for transmitter 7MF4...-.....-.E..) 9 9 9 Interchanging of process connection side 9 9 9 1 2 English rating plate Pressure units in inH2O or psi E R NC B C F Included in delivery of the device: • Brief instructions (Leporello) • CD-ROM with detailed documentation • Sealing plug(s) or sealing screw(s) for the process flanges(s) 3) 9 9 A50 Ordering example: Item line 1: 7MF4634-1EY20-1AA1 Item line 2: 7MF4912-3GE01 2) A30 A31 9 Ordering information: 1st order item: Pressure transmitter 7MF4634-... 2nd order item: Mounting flange 7MF4912-... 1) Plug • Han 7D (metal, gray) • Han 8U (instead of Han 7D) 9 2 3 Electrical connection / cable entry • Screwed gland M20x1.5 • Screwed gland ½-14 NPT • Plug M12 incl. mating connector3) 9 9 9 9 9 2 Explosion protection • Without • With ATEX, Type of protection: - "Intrinsic safety (EEx ia)" - "Explosion-proof (EEx d)"1) - "Intrinsic safety and explosion-proof e nclosure (EEx ia + EEx d)"2) - "Ex nA/nL (zone2)" - "Intrinsic safety, explosion-proof enclosure and dust explosion protection (EEx ia + EEx d + Zone 1D/2D)"2) (not for DS III FF) • With FM + CSA, Type of protection: - "Intrinsic safety and explosion-proof (is + xp)"1) A20 A21 A22 A23 2 9 9 9 9 0 Version • Standard version • International version, English label inscriptions, documentation in 5 languages on CD O-rings for process flanges on low-pressure side (instead of FPM (Viton)) • PTFE (Teflon) • FEP (with silicone core, approved for food) • FFPM (Kalrez, compound 4079) • NBR (Buna N) 9 9 9 9 D E F G Non-wetted parts materials Process flange screws Electronics housing Stainless steel Stainless steel FF Add "-Z" to Order No. and specify Order code. 1 7 Y77 - 7777 Process connection of low-pressure side Female thread ¼-18 NPT with flange connection • Mounting thread M10 to DIN 19213 (only for replacement needs) • Mounting thread 7/16-20 UNF to EN 61518 HART PA Further designs DS III PA series (PROFIBUS PA) Nominal measuring range 250 mbar (3.63 psi) 600 mbar (8.70 psi) 1600 mbar (23.2 psi) 5 bar (72.5 psi) Order code Selection and Ordering data SITRANS P pressure transmitter for level Without cable gland, with blanking plug. With enclosed cable gland EEx ia and blanking plug. Not together with types of protection "Explosion-proof" and "Intrinsic safety and explosion-proof" H01 9 Siemens FI 01 · 2009 2/129 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for level Selection and Ordering data Order code Additional data HART PA FF Add "-Z" to Order No. and specify Order code. 2 9 Measuring range to be set Specify in plain text (max. 5 digits): Y01: ... up to ... mbar, bar, kPa, MPa, psi Y01 Measuring point number (TAG No.) Max. 16 characters, specify in plain text: Y15: ........................................... Y15 9 9 9 Measuring point text Max. 27 characters, specify in plain text: Y16: ........................................... Y16 9 9 9 Entry of HART address (TAG) Max. 8 characters, specify in plain text: Y17: ........................................... Y17 9 Setting of pressure indicator in pressure Y21 units Specify in plain text (standard setting: mA): Y21: mbar, bar, kPa, MPa, psi, ... Note: The following pressure units can be selected: bar, mbar, mm H2O*), inH2O*), ftH2O*), mmHG, inHG, psi, Pa, kPa, MPa, g/cm2, kg/cm2, Torr, ATM or % *) ref. temperature 20 °C 9 1) Setting of pressure indicator in non-pressure units Specify in plain text: Y22: ..... up to ..... l/min, m3/h, m, USgpm, ... (specification of measuring range in pressure units "Y01" is essential, unit with max. 5 characters) Y22 + Y01 Preset bus address (possible between 1 and 126) Specify in plain text: Y25: ..................... Y25 9 Only "Y01", "Y21", "Y22", "Y25" and "D05" can be factory preset 9 = available 1) 9 Not together with over-filling safety device for flammable and non-flammable liquids (Order code "E08") 9 9 Selection and Ordering data Order No.Ord. code Mounting flange 7MF 4 9 1 2 - Directly mounted on the SITRANS P pressure transmitter (converter part) for level, for DS III series 3 7777 Connection acc. to EN 1092-1 Nom. diam. Nom. press. DN 80 PN 40 DN 100 PN 16 PN 40 Connection acc. to ASME B16.5 Nom. diam. Nom. press. 3 inch Class 150 Class 300 4 inch Class 150 Class 300 Other version, add Order code and plain text: Nominal diameter: ...; Nominal pressure: ... Z J1Y • Monel 400, mat. No. 2.4360 • Hastelloy B2, mat. No. 2.4617 • Hastelloy C276, mat. No. 2.4819 • Hastelloy C4, mat. No. 2.4610 • Tantalum G H J U K Other version, add Order code and plain text: material of parts in contact with the medium: ... Sealing face, see "Technical specifications" Z Other version, add Order code and plain text: filling liquid: ... 1) 2) Siemens FI 01 · 2009 Q R T U A D E0 F Filling liquid • Silicone oil M5 • Silicone oil M50 • High-temperature oil • Halocarbon oil (for O2 measurements) • Glycerin / water2) • Food oil (FDA-listed) 2/130 D G H Wetted parts materials • Stainless steel 316L - Coated with PFA - Coated with PTFE - Coated with ECTFE1) Tube length • Without • 50 mm (1.97 inch) • 100 mm (3.94 inch) • 150 mm (5.90 inch) • 200 mm (7.87 inch) Other version: add Order code and plain text: Tube length: ... For vacuum on request Not suitable for use in low-pressure range 777 K1Y 0 1 2 3 4 9 L1Y 1 2 3 4 6 7 9 M1 Y © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for level Selection and Ordering data Order code HART PA and FF Further designs Add "-Z" to Order No. and specify Order code. A01 Flame flashover lock-out For mounting on zone 0 (including documentation) 9 9 Quality inspection certificate (Factory cali- C11 bration) to IEC 60770-2 9 9 Acceptance test certificate To EN 10204-3.1 C12 9 9 Vacuum-proof design (for use in low-pressure range) V04 9 9 Calculation of span of associated Y05 pressure transmitter (enclose filled-in questionnaire with order) Note: suffix "Y01" required with pressure transmitter! 9 9 2 9 = available Siemens FI 01 · 2009 2/131 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for level ■ Dimensional drawings approx. 30 (1.18)5) 185 100 (3.94) 2 51 (2.0) 6 15 (0.6) 144 (5.67) 74 (2.9) 51) 90 (3.6)4) L 9 165 (6.5) 2 3 3 1 k D d5 d4 8 108 (4.25) 54 (2.1) Space for rotation of housing nxd 2 b approx. 96 (3.78) 1 2 3 4 5 6 8 9 1) 2) 3) 4) 5) f Process connection of low pressure side ¼-18 NPT (EN 61 518) Blanking plug Electrical connection: screwed gland Pg 13.5 (adapter) 2) 3), screwed gland M20x1.5, screwed gland ½-14 NPT or Han 7D/ Han 8U plug 2) 3) Terminal side Electronics side, digital display (longer overall length for cover with window) Protective cover over keys Sealing screw with valve (option) Screw cover safety bracket (only for type of protection "Explosion-proof enclosure", not shown in the drawing) 6 51) 41) Allow approx. 20 mm (0.79 inch) thread length in addition Not with type of protection "Explosion-proof enclosure" Not with type of protection "FM + CSA [is + xp]" 92 mm (3.62 inch) for minimum distance to permit rotation without indicator Approx. 45 mm (1.77 inch) for Pg 13.5 with adapter SITRANS P pressure transmitters, DS III HART series for level, including mounting flange, dimensions in mm (inch) Connection to EN 1092-1 Nom. diam. Nom. press. b D d d2 d4 d5 dM f k n L mm mm mm mm mm mm mm mm mm mm mm 0, 50, 100, 150 or 200 DN 80 PN 40 24 200 90 18 138 76 72 1) 2 160 8 DN 100 PN 40 20 220 115 18 158 94 89 2 180 8 PN 40 24 235 115 22 162 94 89 2 190 8 Nom. press. b D d2 d4 d5 dM f k lb/sq.in. inch inch inch inch inch inch inch inch (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) 150 0.94 (23.8) 7.5 (190.5) 0.75 (19.0) 5 (127) 3 (76) 2.81 1) (72) 0.06 (1.6) 6 (152.4) 4 300 1.12 (28.6) 0.94 (23.8) 8.25 (209.5) 9 (228.5) 0.87 (22.2) 0.75 (19.0) 5 (127) 6.19 (157.2) 3 (76) 3.69 (94) 2.81 1) (72) 3.5 (89) 0.06 (1.6) 0.06 (1.6) 6.69 (168.3) 7.5 (190.5) 8 1.25 (31.7) 10 (254) 0.87 (22.2) 6.19 (157.2) 3.69 (94) 3.5 (89) 0.06 (1.6) 7.88 (200) 8 Connection to ASME B16.5 Nom. diam. 3 inch 4 inch 150 300 d: Internal diameter of gasket to DIN 2690 dM: Effective diaphragm diameter 2/132 Siemens FI 01 · 2009 1) n L inch (mm) 8 89 mm = 3½ inch with tube length L = 0. 0, 2, 3.94, 5.94 or 7.87 (0, 50, 100, 150 or 200) © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for gage, absolute and differential pressure, flow and level DS III series for level approx. 30 (1.18) 185 100 (3.94) 51 (2.0) 6 15 (0.6) 144 (5.67) 74 (2.9) 2 3 51) 90 (3.6)4) L 9 165 (6.5) 2 1 k D d5 d4 8 108 (4.25) 54 (2.1) Space for rotation of housing nxd 2 b f 1 2 3 4 5 6 8 9 1) 2) 3) 4) Process connection of low pressure side ¼-18 NPT (EN 61518) Blanking plug Electrical connection: - screwed connection M20x1,5 3), - screwed connection ½-14 NPT or - PROFIBUS plug M12 2) 3) Terminal side Electronics side, digital display (longer overall length for cover with window) Protective cover over keys Sealing screw with valve (option) Screw cover safety bracket (only for "explosion-proof enclosure", not shown in the drawing) 6 51) 41) Allow approx. 20 mm (0.79 inch) thread length in addition Not with type of protection "Explosion-proof enclosure" Not with type of protection "FM + CSA [is + xp]" 92 mm (3.62 inch) for minimum distance to permit rotation with indicator SITRANS P pressure transmitters, DS III PA and FF series for level, including mounting flange, dimensions in mm (inch) Connection to EN 1092-1 Nom. diam. Nom. press. b D d d2 d4 d5 dM f k n mm mm mm mm mm mm mm mm mm mm mm 24 200 90 18 138 76 721) 2 160 8 0, 50, 100, 150 or 200 DN 80 PN 40 DN 100 PN 40 20 220 115 18 158 94 89 2 180 8 PN 40 24 235 115 22 162 94 89 2 190 8 Nom. press. b D d2 d4 d5 dM f k lb/sq.in. inch inch inch inch inch inch inch inch (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) 150 0.94 (23.8) 7.5 (190.5) 0.75 (19.0) 5 (127) 3 (76) 2.811) (72) 0.06 (1.6) 6 (152.4) 4 300 1.12 (28.6) 8.25 (209.5) 0.87 (22.2) 5 (127) 3 (76) 2.811) (72) 0.06 (1.6) 6.69 (168.3) 8 150 0.94 (23.8) 9 (228.5) 0.75 (19.0) 6.19 (157.2) 3.69 (94) 3.5 (89) 0.06 (1.6) 7.5 (190.5) 8 300 1.25 (31.7) 10 (254) 0.87 (22.2) 6.19 (157.2) 3.69 (94) 3.5 (89) 0.06 (1.6) 7.88 (200) 8 L Connection to ASME B16.5 Nom. diam. 3 inch 4 inch d: Internal diameter of gasket to DIN 2690 dM: Effective diaphragm diameter 1) n L inch (mm) 0, 2, 3.94, 5.94 or 7.87 (0, 50, 100, 150 or 200) 89 mm = 3½ inch with tube length L = 0. Siemens FI 01 · 2009 2/133 © Siemens AG 2008 SITRANS P measuring instruments for pressure SITRANS P Accessories Supplementary electronics for 4-wire connection ■ Overview Structural design 2 Dimensions (W x H x D) in mm (inch) 80 x 120 x 60 (3.15 x 4.72 x 2.36) Electrical connection Screw terminals (Pg 13.5 cable inlet) or Han 7D / Han 8U plug Power supply Supply voltage 230 V AC (-10 ... +6%, 47 ... 63 Hz, approx. 6 VA) or 24 V AC/DC (24 V AC ± 10%, 47 ... 63 Hz, approx. 3 VA) Permissible ripple (within the specified limits) Approx. 2.5 Vpp ■ Dimensional drawings SITRANS P pressure transmitter with supplementary electronics for 4wire connection Direct connection of the supplementary electronics to a SITRANS P pressure transmitter from the DS III HART series produces a transmitter for four-wire connection. The supplementary electronics cannot be attached to explosionprotected pressure transmitters. The supplementary electronics is fitted in a light metal housing which is mounted on the left side of the pressure transmitter. Note on ordering: The supplementary electronics has to be be ordered through the supplementary options of the pressure transmitter in question. ■ Technical specifications SITRANS P pressure transmitters with supplementary electronics for fourwire connection, dimension drawing, dimensions in mm (inch) SITRANS P, supplementary electronics for 4-wire connection Output Output signal 0 ... 20 mA or 4 ... 20 mA Load Max. 750 Ω Voltage measurement Linear (square-rooting in transmitter if necessary) Electrical isolation Between power supply and input/ output Measuring accuracy To EN 60770-1 Conformity error (in addition to transmitter) ≤ 0.15% of set span Influence of ambient temperature ≤ 0.1% per 10 K Power supply effect ≤ 0.1% per 10% change in voltage or frequency ■ Schematics Terminals -50 ... +85 °C (-58 ... +185 °F) Degree of protection IP54 to EN 60529 Electromagnetic compatibility (EMC) EN 50081, EN 50082 2/134 Siemens FI 01 · 2009 3 4 5 U a 6 7 5 1 4 2 plugs 6 7 5 1 4 6 H SL SL 2 3 + Ia - UH 6 7 2 5 1 3 4 SL 2 3 + Ia - -20 ... +80 °C (-4 ... +176 °F) Storage temperature 2 - 1 HAN 8U/7D plug Rated conditions Ambient temperature 1 I ≤ 0.1% per 100% change Load effect + UH AC 230 V UC 24 V Han 7D Han 7D Ia SL Protective earth conductor Output current Han 7D Han 8U UH Power supply Supplementary electronics for 4-wire connection, connection diagram © Siemens AG 2008 SITRANS P measuring instruments for pressure SITRANS P Accessories Supplementary electronics for 4-wire connection Selection and Ordering data Order code Supplementary electronics for 4-wire connection Order No. of the transmitter 7MF4.33-.....-1AB. add "-Z" and Order code. V77 Power supply 24 V AC/DC 230 V AC Electrical connection Terminals; 2 Pg screwed glands, to left 2 Han 7D/Han 8U plugs incl. mating connector, to left 1 Han 7D plug incl. mating connector, angled Terminals; 1 Pg screwed gland, downwards 1 Han 8U plug incl. mating connector, downwards (observe arrangement of plug and differential pressure line) Terminals; 2 Pg screwed glands, to left 2 Han 7D plugs incl. mating connector, to left Output current 0 ... 20 mA 4 ... 20 mA Selection and Ordering data 2 1 3 5 6 9 7 8 0 1 Order No. Accessories Instruction Manual German/English E86060-K6017A131-A3 Siemens FI 01 · 2009 2/135 © Siemens AG 2008 SITRANS P measuring instruments for pressure SITRANS P Accessories Accessories / spare parts for SITRANS P P300 and DS III series 2 Selection and Ordering data Order No. Selection and Ordering data Replacement measuring cell for pressure for SITRANS P, DS III, DS III PA and DS III FF series 7MF 4 9 9 0 - F) 7 M F 4 9 9 2 Replacement measuring cell for absolute pressure (from the pressure series) for SITRANS P, DS III, DS III PA and DS III FF series 7 7 7 7 0 - 0 D C 0 Measuring cell filling Measuring cell cleaning Silicone oil Standard Inert liquid Grease-free Measured span 0.01 ... 1 bar g 0.04 ... 4 bar g 0.16 ... 16 bar g 0.63 ... 63 bar g 1.6 ... 160 bar g 4.0 ... 400 bar g (0.15 ... 14.5 psi g) (0.58 ... 58 psi g) (2.32 ... 232 psi g) (9.14 ... 914 psi g) (23.2 ... 2320 psi g) (58.0 ... 5802 psi g) 7777 0 - 0 DC 0 Measuring cell filling Measuring cell cleaning Silicone oil Standard Inert liquid Grease-free 1 3 Measured span 8.3 ... 250 mbar a 43 ... 1300 mbar a 0.16 ... 5 bar a 1 ... 30 bar a B C D E F G Stainless steel Stainless steel Hastelloy 0 1 2 3 Order code Please add "-Z" to Order No. and specify Order code. Acceptance test certificate to EN 10204-3.1 2/136 Siemens FI 01 · 2009 Stainless steel Hastelloy Hastelloy A B C Process connection • Connection shank G½B to EN 837-1 • Female thread ½-14 NPT • Oval flange made of stainless steel, max. span 160 bar (2320 psi) - Mounting thread 7/16-20 UNF to EN 61518 - Mounting thread M10 to DIN 19213 Further designs 1 3 D F G H Wetted parts materials Seal diaphragm Process connection Wetted parts materials Seal diaphragm Process connection Stainless steel Hastelloy Hastelloy (0.12 ... 3.63 psi a) (0.62 ... 18.9 psi a) (2.32 ... 72.5 psi a) (14.5 ... 435 psi a) Order No. C12 Stainless steel Stainless steel Hastelloy A B C Process connection • Connection shank G½B to EN 837-1 • Female thread ½-14 NPT • Oval flange made of stainless steel, max. span 160 bar (2320 psi) - Mounting thread 7/16-20 UNF to EN 61518 - Mounting thread M10 to DIN 19213 Further designs 0 1 2 3 Order code Please add "-Z" to Order No. and specify Order code. Acceptance test certificate to EN 10204-3.1 F) Subject to export regulations AL: 9I999, ECCN: N. C12 © Siemens AG 2008 SITRANS P measuring instruments for pressure SITRANS P Accessories Accessories / spare parts for SITRANS P P300 and DS III series Order No. Selection and Ordering data Order No. Selection and Ordering data Spare parts / Accessories Spare parts / Accessories Replacement measuring cell for absolute pres- F) 7 M F 4 9 9 3 sure (from the differential pressure series) for 77777 - 0 DC 0 SITRANS P, DS III, DS III PA and DS III FF series Replacement measuring cell for differential pressure and PN 32/160 (MWP 464/2320 psi) for SITRANS P, DS III, DS III PA and DS III FF series 77777 - 0 DC 0 Measuring cell filling Measuring cell cleaning Silicone oil Standard Inert liquid Grease-free Measuring cell filling Measuring cell cleaning Silicone oil Standard Inert liquid Grease-free 1 3 Measured span 8.3 ... 250 mbar a 43 ... 1300 mbar a 0.16 ... 5 bar a 1 ... 30 bar a 5.3 ... 100 bar a (0.12 ... 3.63 psi a) (0.62 ... 18.9 psi a) (2.32 ... 72.5 psi a) (14.5 ... 435 psi a) (76.9 ... 1450 psi a) 1 3 E) E) E) D F G H KE Wetted parts materials Seal diaphragm Parts of measuring cell Stainless steel Hastelloy Hastelloy Tantalum Monel Gold Stainless steel Stainless steel Hastelloy Tantalum Monel Gold E) A B C E H L Process connection Female thread ¼-18 NPT with flange connection • Sealing screw opposite process connection - Mounting thread M10 to DIN 19213 - Mounting thread 7/16-20 UNF to EN 61518 • Vent on side of process flange1) - Mounting thread M10 to DIN 19213 - Mounting thread 7/16-20 UNF to EN 61518 Further designs Please add "-Z" to Order No. and specify Order code. O-rings for process flanges (instead of FPM (Viton)) • PTFE (Teflon) • FEP (with silicone core, approved for food) • FFPM (Kalrez, compound 4079) • NBR (Buna N) Measured span PN 32 (MWP 464 psi) 1 ... 20 mbar1) (0.4015 ... 8.03 inH2O) B PN 160 (MWP 2320 psi) 1 ... 60 mbar (0.4015 ... 24.09 inH2O) 2.5 ... 250 mbar (1.004 ... 100.4 inH2O) 6 ... 600 mbar (2.409 ... 240.9 inH2O) 16 ... 1600 mbar (6.424 ... 642.4 inH2O) 50 ... 5000 mbar (20.08 ... 2008 inH2O) 0.3 ... 30 bar (4.35 ... 435 psi) C D E F G H Wetted parts materials (stainless steel process flanges) 0 2 4 6 Non-wetted parts materials • Stainless steel process flange screws 7MF 4 9 9 4 - 2 Order code A20 A21 A22 A23 Seal diaphragm Parts of measuring cell Stainless steel Hastelloy Hastelloy Tantalum2) Monel2) Gold2) Stainless steel Stainless steel Hastelloy Tantalum Monel Gold A B C E H L Process connection Female thread ¼-18 NPT with flange connection • Sealing screw opposite process connection - Mounting thread M10 to DIN 19213 - Mounting thread 7/16-20 UNF to EN 61518 • Vent on side of process flange - Mounting thread M10 to DIN 19213 - Mounting thread 7/16-20 UNF to EN 61518 0 2 4 6 Non-wetted parts materials Stainless steel process flange screws 2 Further designs Order code Please add "-Z" to Order No. and specify Order code. Acceptance test certificate to EN 10204-3.1 C12 Process connection G½A D16 Remote seal flanges (not together with K01, K02 and K04) D20 O-rings for process flanges (instead of FPM (Viton)) • PTFE (Teflon) • FEP (with silicone core, approved for food) • FFPM (Kalrez, compound 4079) • NBR (Buna N) H02 Acceptance test certificate to EN 10204-3.1 C12 Vent on side for gas measurements Remote seal flanges (not together with K01, K02 and K04) D20 K00 Vent on side for gas measurements H02 Stainless steel process flanges for vertical differential pressure lines (not together with K01, K02 and K04) H03 Process flanges • without • with process flange made of - Hastelloy - Monel - Stainless steel with PVDF insert max. PN 10 (MWP 145 psi) max. temperature of medium 90 °C (194 °F) 1) K01 K02 K04 Not for span "5.3 ... 100 bar (76.9 ... 1450 psi)" E) Combinations of the versions marked with E) are subject to the export regulations AL: 2B230, ECCN: N. F) Subject to export regulations AL: 9I999, ECCN: N. Process flanges • without • with process flange made of - Hastelloy - Monel - Stainless steel with PVDF insert max. PN 10 (MWP 145 psi) max. temperature of medium 90 °C (194 °F) 1) 2) A20 A21 A22 A23 K00 K01 K02 K04 Not suitable for connection of remote seal Only together with max. spans 250, 1600, 5000 and 30000 mbar (3.63, 23.2, 72.5 and 435 psi). Siemens FI 01 · 2009 2/137 2 © Siemens AG 2008 SITRANS P measuring instruments for pressure SITRANS P Accessories Accessories / spare parts for SITRANS P P300 and DS III series Selection and Ordering data Order No. Spare parts / Accessories 2 Replacement measuring cell for differential pressure and PN 420 (MWP 6092 psi) for SITRANS P, DS III, DS III PA and DS III FF series Measuring cell filling Silicone oil Measuring cell cleaning Standard Measured span 2.5 ... 250 mbar 6 ... 600 mbar 16 ... 1600 mbar 50 ... 5000 mbar 0.3 ... 30 bar (1.004 ... 100.4 inH2O) (2.409 ... 240.9 inH2O) (6.424 ... 642.4 inH2O) (20.08 ... 2008 inH2O) (4.35 ... 435 psi) 7MF 4 9 9 5 77777 - 0 DC 0 1 D E F G H Stainless steel Stainless steel Gold A B L Process connection Female thread ¼-18 NPT with flange connection • Sealing screw opposite process connection 7 - Mounting thread /16-20 UNF to EN 61518 • Vent on side of process flange - Mounting thread M12 to DIN 19213 Non-wetted parts materials • Stainless steel process flange screws Order code A20 A21 A22 A23 Acceptance test certificate to EN 10204-3.1 C12 Stainless steel process flanges for vertical differential pressure lines H03 without process flanges K00 Not together with max. span 600 mbar (240.9 inH2O) 2/138 Siemens FI 01 · 2009 Measuring cell cleaning Standard 1 Rated measuring range 250 mbar 600 mbar 1600 mbar 5 bar (3.63 psi) (8.70 psi) (23.2 psi) (72.5 psi) D E F G Seal diaphragm Parts of measuring cell Stainless steel Stainless steel A Process connection of low-pressure side Female thread ¼-18 NPT with flange connection • Sealing screw opposite process connection - Mounting thread M10 to DIN 19213 0 - Mounting thread 7/16-20 UNF to EN 61518 2 2 Order code Please add "-Z" to Order No. and specify Order code. 2 Please add "-Z" to Order No. and specify Order code. 1) Measuring cell filling Silicone oil Further designs 5 7 - Mounting thread 7/16-20 UNF to EN 61518 O-rings for process flanges (instead of FPM (Viton)) • PTFE (Teflon) • FEP (with silicone core, approved for food) • FFPM (Kalrez, compound 4079) • NBR (Buna N) 77777 - 0 DC 0 Non-wetted parts materials • Stainless steel process flange screws 1 3 - Mounting thread M12 to DIN 19213 Further designs 7MF 4 9 9 6 - Replacement measuring cell for level for SITRANS P, DS III, DS III PA and DS III FF series Wetted parts materials (stainless steel process flanges) Parts of measuring cell Stainless steel Hastelloy Gold1) Order No. Spare parts / Accessories Wetted parts materials (stainless steel process flanges) Seal diaphragm Selection and Ordering data O-rings for process flanges (instead of FPM (Viton)) • PTFE (Teflon) • FEP (with silicone core, approved for food) • FFPM (Kalrez, compound 4079) • NBR (Buna N) A20 A21 A22 A23 Acceptance test certificate to EN 10204-3.1 C12 without process flanges K00 © Siemens AG 2008 SITRANS P measuring instruments for pressure SITRANS P Accessories Accessories / spare parts for SITRANS P P300 and DS III series Order No. Selection and Ordering data Spare parts / Accessories Mounting bracket and mounting parts for pressure transmitters DS III, DS III PA and DS III FF series (7MF403.-.....-..C.) for absolute pressure transmitters DS III, DS III PA and DS III FF series (7MF423.-.....-..C.) • made of steel • made of stainless steel Mounting bracket and mounting parts for pressure transmitters DS III, DS III PA and DS III FF series (7MF403.-.....-..A., -..B. and -..D.) for absolute pressure transmitters DS III, DS III PA and DS III FF series (7MF423.-.....-..A., -..B. and -..D.) • Made of steel • Made of stainless steel 7MF4997-1AB 7MF4997-1AH 7MF4997-1AC } 7MF4997-1AJ Mounting bracket and mounting parts for differential pressure transmitters with flange thread M10 DS III, DS III PA and DS III FF series (7MF433.-... and 7MF443.-...) • made of steel 7MF4997-1AD • made of stainless steel } 7MF4997-1AK Mounting bracket and mounting parts for differential pressure transmitters with flange thread M12 DS III, DS III PA and DS III FF series (7MF453.-...) • made of steel • made of stainless steel 7MF4997-1AE 7MF4997-1AL 7MF4997-1AF 7MF4997-1AM Cover Made of die-cast aluminium, including gasket, for DS III, DS III PA and DS III FF series F) 7MF4997-1BB • without window • with window } 7MF4997-1BE F) Digital indicator Including mounting material for DS III, DS III PA and DS III FF series Measuring-point label • without inscription (5 off) • with inscription (1 off) Data according to Y01 or Y02, Y15 and Y16 (see "SITRANS P pressure transmitters") Mounting screws for measuring-point label, earthing and connection terminals or for digital indicator (50 off) Sealing screws (1 set = 2 off) for process flange • made of stainless steel • made of Hastelloy F) 7MF4997-1CH Screw plug with valve (1 set = 2 off) • made of stainless steel • made of Hastelloy } 7MF4997-1CP F) 7MF4997-1CQ 7MF4997-1CG Electronics • for DS III series • for DS III PA series • for DS III FF series 7MF4997-1DK 7MF4997-1DL 7MF4997-1DM Connection board • for DS III series • for DS III PA and DS III FF series 7MF4997-1DN 7MF4997-1DP O-rings for process flanges made of • FPM (Viton) • PTFE (Teflon) • FEP (with silicone core, approved for food) • FFPM (Kalrez, compound 4079) • NBR (Buna N) F) F) F) F) F) Weldable sockets for PMC connection for DS III and P300 series • PMC Style Standard: Thread 1½“ • PMC Style Mini bolt: front-flush 1“ F) 7MF4997-2HB Sealing rings for PMC connection (packing unit: 5 pcs) • Sealing ring made of PTFE for PMC Style Standard: Thread 1½" • Sealing ring made of Viton for PMC Style Minibolt: front-flush 1“ F) 7MF4997-1BC F) 7MF4997-1BF 7MF4997-1BR 7MF4997-1CA 7MF4997-1CB-Z Y..: ................ 7MF4997-1CD 7MF4997-2DA 7MF4997-2DB 7MF4997-2DC 7MF4997-2DD 7MF4997-2DE 7MF4997-2HA F) 7MF4997-2HC F) 7MF4997-2HD Weldable socket for TG 52/50- and TG 52/150 connection for DS III and P300 series • TG 52/50 connection • TG 52/150 connection Mounting bracket and mounting parts for differential and absolute pressure transmitters with flange thread 7/16-20 UNF DS III, DS III PA and DS III FF series (7MF433.-..., 7MF443.-... and 7MF453.-...) • made of steel • made of stainless steel Cover Made of stainless steel, including gasket, for DS III, DS III PA and DS III FF series • without window • with window Order No. Selection and Ordering data 7MF4997-2HE 7MF4997-2HF Seals for TG 52/50 and TG 52/150 made of silicone Seals for flange connection with flushmounted diaphragm Material FPM (Viton), 10 units • DN 25, PN 40 (M11) • DN 25, PN 100 (M21) • 1", class 150 (M40) • 1", class 300 (M45) 7MF4997-2HG F) F) F) F) 7MF4997-2HH 7MF4997-2HJ 7MF4997-2HK 7MF4997-2HL Mounting bracket and mounting parts for P300 • Made of stainless steel 7MF8997-1AA Lid without window for P300 • Gasket not included 7MF8997-1BA Lid with glass window for P300 • Gasket not included NBR housing gasket for P300 7MF8997-1BD 7MF8997-1BG Measuring point label for P300 • Unlabeled 7MF8997-1CA Cable gland for P300 • Metal • Plastic (blue) 7MF8997-1EA 7MF8997-1EB } Available ex stock F) Subject to export regulations AL: 9I999, ECCN: N. Siemens FI 01 · 2009 2/139 2 © Siemens AG 2008 SITRANS P measuring instruments for pressure SITRANS P Accessories Accessories / spare parts for SITRANS P P300 and DS III series Order No. Selection and Ordering data 2 Instruction Manual1) • for P300 series with HART communication - German - English - French - Spanish - Italian - Leporello German/English • for P300 series with PROFIBUS PA communication - German - English - French - Spanish - Italian - Leporello German/English • for DS III series - German - English - French - Spanish - Italian • for DS III PA series - German - English - French - Spanish - Italian • for DS III FF series - German - English - French (planned) - Spanish (planned) - Italian (planned) A5E00359580 A5E00359579 A5E00359578 A5E00359576 A5E00359577 A5E00359581 A5E00414587 A5E00414588 A5E00414589 A5E00414590 A5E00414591 A5E00414592 A5E00047090 A5E00047092 A5E00053218 A5E00053219 A5E00053220 A5E00053275 A5E00053276 A5E00053277 A5E00053278 A5E00053279 A5E00279627 A5E00279629 A5E00279630 A5E00279632 A5E00279631 Brief instructions (Leporello) • for DS III series, German, English • for DS III PA series, German, English • for DS III FF series, German, English A5E00047093 A5E00053274 A5E00282355 G) A5E00090345 CD with documentation for P300, DS III, DS III PA and DS III FF series German, English, French, Italian, Spanish Instruction Manual for replacement of electronics, measuring cell and connection board • German/English HART modem • with RS232 interface A5E00078060 } 7MF4997-1DA D) • with USB interface } 7MF4997-1DB D) Supplementary electronics for 4-wire connection see page 2/134 } Available ex stock Power supply units see "SITRANS I power supply units and input isolators". 1) You can download the Instruction Manuals free-of-charge from the Internet site www.siemens.com/sitransp. D) Subject to export regulations AL: N, ECCN: EAR99H. G) Subject to export regulations AL: N, ECCN: 5D992B1. 2/140 Siemens FI 01 · 2009 © Siemens AG 2008 SITRANS P measuring instruments for pressure SITRANS P Accessories Accessories / spare parts for SITRANS P P300 and DS III series ■ Dimensional drawings 2 5 5 Mounting bracket for SITRANS P gage and absolute pressure transmitter, DS III series Material of mounting bracket: Sheet-steel Mat. No. 1.0330, chrome-plated, or stainless steel Mat. No. 1.4301 (304) 5 5 5 Mounting bracket for SITRANS P differential pressure transmitter, DS III series, Material of mounting bracket: Sheet-steel Mat. No. 1.0330, chrome-plated, or stainless steel Mat. No. 1.4301 (304) Siemens FI 01 · 2009 2/141 © Siemens AG 2008 SITRANS P measuring instruments for pressure SITRANS P Accessories Factory-mounting of valve manifolds on SITRANS P transmitters ■ Overview 2 The 7MF9011-4FA valve manifolds are sealed with PTFE sealing tape between the transmitter and the valve manifold. SITRANS P transmitters • P300 for relative and absolute pressure, • DS III for relative and absolute pressure (both designs) and • DS III for differential pressure can be delivered factory-fitted with the following valve manifolds: • 7MF9011-4EA and 7MF9011-4FA valve manifolds for relative pressure and absolute pressure transmitters • 7MF9411-5BA and 7MF9411-5CA valve manifolds for absolute pressure and differential pressure transmitters ■ Design The 7MF9011-4EA valve manifolds are sealed with gaskets made of PTFE between transmitter and the valve manifold as standard. Soft iron, stainless steel and copper gaskets are also available for sealing purposes if preferred. The 7MF9411-5BA and 7MF9411-5CA valve manifolds are sealed with PTFE sealing rings between the transmitter and the valve manifold. Once installed, the complete unit is checked under pressure for leaks and is certified leak-proof with a factory certificate to EN 10204 - 2.2. All valve manifolds should preferably be secured with the respective mounting brackets. The transmitters are mounted on the valve manifold and not on the unit itself. If you order a mounting bracket when choosing the option "Factory mounting of valve manifolds", you will receive a mounting bracket for the valve manifold instead of a bracket for mounting the transmitter. If you order an acceptance test certificate 3.1 to EN10204 when choosing the option "Factory mounting of valve manifolds", a separate certificate is provided for the transmitters and the valve manifolds respectively. ■ Selection and Ordering data 7MF9011-4FA valve block on relative and absolute pressure transmitters 7MF9411-5BA valve manifold on absolute and differential pressure transmitters Add -Z to the Order No. of the transmitter and add order codes. Order code Add -Z to the Order No. of the transmitter and add order codes. SITRANS P DSIII 7MF403.-...1.-..., 7MF423.-...1.-... and SITRANS P300 7MF802.-...1.-... With process connection female thread ½-14 NPT in-sealed with PTFE sealing strip Delivery incl. high-pressure test certified by factory certificate to EN10204-2.2 T03 SITRANS P DSIII 7MF433.-…, 7MF443.-… and 7MF453.-…1) mounted with gaskets made of PTFE and screws made of • chromized steel U01 • stainless steel U02 Delivery incl. high-pressure test certified by factory certificate to EN10204-2.2 7MF9011-4EA valve block on relative and absolute pressure transmitters 7MF9411-5CA valve manifold on differential pressure transmitters Add -Z to the Order No. of the transmitter and add order codes. Order code Add -Z to the Order No. of the transmitter and add order codes. SITRANS P DSIII 7MF403.-...0.-..., 7MF423.-...0.-... and SITRANS P300 7MF802.-...0.-... T02 SITRANS P DSIII 7MF443.-... und 7MF453.-…1) • soft iron A70 • stainless steel, Mat. No. 14571 A71 • copper A72 Supplied acceptance test certificate to EN 10204- 3.1 for transmitters and mounted valve manifold C12 Oil and grease-free cleaning for oxygen operation E10 U04 Delivery includes mounting bracket and mounting clips made of Further designs: A02 U03 • stainless steel Further designs: Delivery incl. high-pressure test certified by factory certificate to EN10204-2.2 Delivery includes mounting brackets and mounting clips made of stainless steel (instead of the mounting bracket supplied with the transmitter) • chromized steel Delivery incl. high-pressure test certified by factory certificate to EN10204-2.2 Alternative sealing material: Siemens FI 01 · 2009 Order code mounted with gaskets made of PTFE and screws made of with process connection collar G1/2 A to EN837-1 with gasket made of PTFE between valve manifold and transmitter 2/142 Order code • steel A01 • stainless steel A02 (instead of the mounting bracket supplied with the transmitter) 1) Supplied acceptance test certificate to EN10204-3.1 for transmitters and mounted valve manifold C12 Oil and grease-free cleaning for oxygen operation E10 For 7MF453.-... transmitters, you require a 7/10-20 UNF connection thread in the process flange. © Siemens AG 2008 SITRANS P measuring instruments for pressure SITRANS P Accessories Factory-mounting of valve manifolds on SITRANS P transmitters ■ Dimensional drawings Valve manifolds mounted on SITRANS P DS III 2 Valve manifold 7MF9011-4EA with mounted relative pressure and absolute pressure transmitters, dimensions in mm (inch) Valve manifold 7MF9011-4FA with mounted relative pressure and absolute pressure transmitters Valve manifold 7MF9011-4EA with mounted relative pressure and absolute pressure transmitters Valve manifold 7MF9011-4FA with mounted relative pressure and absolute pressure transmitters, dimensions in mm (inch) Siemens FI 01 · 2009 2/143 © Siemens AG 2008 SITRANS P measuring instruments for pressure SITRANS P Accessories Factory-mounting of valve manifolds on SITRANS P transmitters 2 Valve manifold 7MF9411-5CA with mounted differential pressure transmitter Valve manifold 7MF9411-5BA with mounted differential pressure transmitter 5 Valve manifold 7MF9411-5BA with mounted differential pressure transmitter, dimensions in mm (inch) 5 Valve manifold 7MF9411-5CA with mounted differential pressure transmitter, dimensions in mm (inch) 2/144 Siemens FI 01 · 2009 © Siemens AG 2008 SITRANS P measuring instruments for pressure SITRANS P Accessories Factory-mounting of valve manifolds on SITRANS P transmitters Valve manifolds mounted on SITRANS P300 Valve manifold 7MF9011-4EA with mounted relative pressure and absolute pressure transmitters, dimensions in mm (inch) Valve manifold 7MF9011-4FA with mounted relative pressure and absolute pressure transmitters Valve manifold 7MF9011-4EA with mounted relative pressure and absolute pressure transmitters 2 Valve manifold 7MF9011-4FA with mounted relative pressure and absolute pressure transmitters, dimensions in mm Siemens FI 01 · 2009 2/145 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for hydrostatic level MPS series (submersible sensor) ■ Overview Sensor Diaphragm 2 U const. p U I EM +2 (brown) I , U -1 (blue) 0 B Vent pipe Screen SITRANS P pressure transmitters, MPS series, mode of operation and wiring diagram SITRANS P pressure transmitters, MPS series, are submersible sensors for hydrostatic level measurements. On one side of the sensor, the diaphragm is exposed to the hydrostatic pressure which is proportional to the submersion depth. This pressure is compared with atmospheric pressure. Pressure compensation is carried out using the vent pipe in the connection cable. The pressure transmitters of the MPS series are available for various measuring ranges and with explosion protection as an option. The hydrostatic pressure of the liquid column acts on the sensor diaphragm, and transmits the pressure to the piezo-resistive bridge in the sensor. A junction box and a cable hanger are available as accessories for simple installation. The output voltage of the sensor is applied to the electronic circuit where it is converted into an output current of 4 to 20 mA. SITRANS P pressure transmitters, MPS series (submersible sensor) ■ Benefits • • • • Compact design Simple installation Small error in measurement (0.3%) Degree of protection IP68 ■ Application The cable of the 7MF1570 transmitter must always be connected in the supplied junction box. The junction box has to be installed near the measuring point. If the medium is anything other than water, it is also necessary to check compatibility with the specified materials of the transmitter. ■ Integration SITRANS P pressure transmitters, MPS series, are used in the following branches for example: • Oil and gas industries • Shipbuilding • Water supply ■ Design SITRANS P pressure transmitters, MPS series, have a flushmounted piezo-resistive sensor with stainless steel diaphragm. These pressure transmitters are equipped with an electronic circuit fitted together with the sensor in a stainless steel housing. The cable also contains a strength cord and vent pipe. The diaphragm is protected against external influences by a protective cap. The sensor, electronic circuit and cable are sealed in a common housing of small dimensions. The pressure transmitter is temperature-compensated for a wide temperature range. ■ Function SITRANS P pressure transmitters, MPS series, are for measuring the liquid levels in wells, tanks, channels and dams. 2/146 Siemens FI 01 · 2009 Junction box 7MF1570-8AA, opened © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for hydrostatic level MPS series (submersible sensor) Long-term stability Zero and span • 1 ... 6 mH2O (3 ... 18 ftH2O) 0.25% of full-scale value/year • ≥ 6 mH2O (≥ 18 ftH2O) 0.2% of full-scale value/year Rated operating conditions Ambient conditions • Process temperature -10 ... +80 °C (+14 ... +176 °F) • Storage temperature -40 ... +100 °C (-40 ... +212 °F) Degree of protection to DIN EN 60529 IP68 Design Weight • Pressure transmitters ≈ 0.4 kg (≈ 0.88 lb) • Cable 0.08 kg/m (≈ 0.054 lb/ft) Electrical connection Cable with 2 conductors with screen and vent pipe, strength cord (max. 300 N (67.44 lbf) Material • Seal diaphragm Stainless steel, mat. No. 1.4571/316 Ti • Casing Stainless steel, mat. No. 1.4571/316 Ti • Gasket Viton • Connecting cable Optionally PE/HFFR sheath (non-halogen) or FEP sheath Power supply Measuring point setup, in principle Terminal voltage on pressure transmitter (UB) ■ Technical specifications Certificate and approvals SITRANS P pressure transmitters, MPS series (submersible sensor) Mode of operation Measuring principle 10 ... 36 V DC Piezo-resistive Input The transmitter is not subject to the pressure equipment directive (DGRL 97/23/EC) Explosion protection • Intrinsic safety "i" - Identification TÜV 03 ATEX 2004X Ex II 1 G EEx ia IIC T4 Measured variable Hydrostatic level Measuring range Maximum working pressure • 0 ... 2 mH2O (0 ... 6 ftH2O) • 1.4 bar (20.3 psi) (corresponds to 14 mH2O (42 ftH2O)) • 0 ... 4 mH2O (0 ... 12 ftH2O) • 1.4 bar (20.3 psi) (corresponds to 14 mH2O (42 ftH2O)) • 0 ... 5 mH2O (0 ... 15 ftH2O) • 1.4 bar (20.3 psi) (corresponds to 14 mH2O (42 ftH2O)) Weight 0.2 kg (0.44 lb) • 3.0 bar (43.5 psi) (corresponds to 30 mH2O (90 ftH2O)) Electrical connection 2 x 3-way (28 ... 18 AWG) Cable entry 2 x M20x1.5 Polycarbonate • 0 ... 6 mH2O (0 ... 18 ftH2O) Junction box Application Design • 0 ... 10 mH2O (0 ... 30 ftH2O) • 3.0 bar (43.5 psi) (corresponds to 30 mH2O (90 ftH2O)) Enclosure material • 0 ... 20 mH2O (0 ... 60 ftH2O) • 6.0 bar (87.0 psi) (corresponds to 60 mH2O (180 ftH2O)) Screw for cable strength cord Output signal 4 ... 20 mA Degree of protection to DIN EN 60529 Accuracy To EN 60770-1 Error in measurement (including non-linearity, hysteresis and repeatability, at 25 °C (77 °F)) 0.3% of full-scale value (typical) Output Vent pipe for atmospheric pressure Rated operating conditions IP54 Cable hanger Application Influence of ambient temperature For connecting the transmitter cable For mounting the transmitter Design Zero and span • 1 ... 6 mH2O (3 ... 18 ftH2O) 0.45%/10 K of full-scale value • ≥ 6 mH2O (≥ 18 ftH2O) 0.3%/10 K of full-scale value Weight 0.16 kg (0.35 lb) Material Galvanized steel, polyamide Siemens FI 01 · 2009 2/147 2 © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for hydrostatic level MPS series (submersible sensor) Order No. C) 7 M F 1 5 7 0 - 7 7 A 0 7 7 7 7 SITRANS P pressure transmitters for pressure, MPS series (submersible sensor) Selection and Ordering data Protective cap Cable sheath + (brown) 2-wire system Cable length L 10 m 10 m 25 m 25 m 25 m 25 m 0 ... 6 ftH2O 0 ... 12 ftH2O 0 ... 18 ftH2O 0 ... 30 ftH2O 0 ... 60 ftH2O 32 ft 32 ft 82 ft 82 ft 82 ft } } } } } } 158 (6.2) SITRANS P pressure transmitters, MPS series, dimensions in mm (inch) K L M N P 50 (1.97) 57 (2.25) 22 (0.87) M20x1.5 Z Mounting hole J1Y Explosion protection 1 • without } • with, type of protection "Intrinsic safe- } ty" (Ex II 1 G EEx ia IIC T4) • With approval for drinking water to } WRAS and ACS D) Venting valve 2 6 Further designs Order code Quality inspection certificate (Factory calibration) to IEC 60770-2, add "-Z" to Order No. and Order code. C11 M20x1.5 65 (2.56) Order No. Quality inspection certificate (Factory calibration) to IEC 60770-2 supplied later, specify factory no. of transmitter for this porpose. 7MF1564-8CC11 Junction box, dimensions in mm (inch) Accessories (as spare parts) Junction box for connecting the transmitter cable 7MF1570-8AA Cable hanger for mounting the pressure transmitter 7MF1570-8AB } Available ex stock Power supply units see "SITRANS I power supply units and input isolators". 1) Special measuring ranges between 0 ... 1 mH2O (0 ... 3 ftH2O) and 0 ... 200 mH2O (0 ... 656 ftH2O) and special cable lengths up to 1000 m (3281ft) are possible. With Ex versions the max. special cable length is 50 m (150 ft). The length of free-hanging cable should not exceed 375 m. C) Subject to export regulations AL: N, ECCN: EAR99. D) Subject to export regulations AL: N, ECCN: EAR99H. Cable hanger, dimensions in mm (inch) 2/148 Siemens FI 01 · 2009 Screen Cable sheath 8.3 (0.33) diam. (black or blue, PE/HFFR) Flexible cable with 0.5 mm2 (0.00078 inch2) cross-section Vent pipe 1 (0.04) diam. (inner diameter) Protective cap with 4 x 3 diam. (4 x 0.12 diam.) holes (black, PA) C D B E F G Special measuring range/Special cable length 1) Specify measuring range and cable length in plain text - (blue) L 30 (1.2) Measuring range 0 ... 2 mH2O 0 ... 4 mH2O 0 ... 5 mH2O 0 ... 6 mH2O 0 ... 10 mH2O 0 ... 20 mH2O 1 5 94 (3.7) } Strength cord (white) 30 (1.2) Cable material PE FEP Vent pipe Ø 27 (1.1 diam.) Note: Junction box and cable hanger included in delivery 79 (3.1) 2 ■ Dimensional drawings 22 (0.87) © Siemens AG 2008 SITRANS P measuring instruments for pressure Transmitters for hydrostatic level MPS series (submersible sensor) ■ More information Determination of the measuring range in case of media with a density ≠ 1000 kg/m3 (medium ≠ water) 2 + ρ Calculation of the measuring range: p=ρxgxH with: ρ = density of medium g = local acceleration due to gravity H = maximum level Example: Medium: Diesel fuel = 850 kg/m3 Acceleration due to gravity: 9.81 m/s2 Start-of-scale : 0 m Maximum level: 6,2 m Calculation: p = 850 kg/m3 x 9.81 m/s2 x 6.2 m p = 51698.7 N/m2 p = 517 mbar Transmitter to be ordered: 7MF1570-5ZA02-Z J1Y: 0 ... 517 mbar; able length e.g. 8 m Siemens FI 01 · 2009 2/149 © Siemens AG 2008 SITRANS P measuring instruments for pressure Remote seals for transmitters and pressure gages Technical description ■ Overview capillaries of equal length must always be used to connect a remote seal to a pressure transmitter for differential pressure. In many cases the pressure transmitter and the measured medium have to be physically separated. It is then necessary to use a remote seal. 2 The remote seals can be used with the following SITRANS P pressure transmitter series: • Pressure (P300, DS III, DS III PA, DS III FF) • Absolute pressure (P300, DS III, DS III PA, DS III FF) • Differential pressure and flow (DS III, DS III PA, DS III FF) Note When configuring your remote seal, be sure to read the information about transmission response, temperature error and response time to be found in the sections "Function" and "Technical data". Only then will the remote seal work to optimum effect. The remote seal can be optionally equipped with a projecting diaphragm (tube). Remote seals of sandwich design are fitted with a dummy flange. Designs Diaphragm seal With diaphragm seals, the pressure is measured by means of a flat diaphragm which rests in a bed. The following types of diaphragm seals exist: ■ Benefits • No direct contact between the pressure transmitter and the medium • Individual configuration of the pressure transmitter for perfect adaptation to the operating conditions • Available in many versions • Specially designed for difficult operating conditions • Quick-release versions available for the food industry ■ Application Remote seal systems should be used if a separation between the measured medium and the measuring instrument is essential or appropriate. Examples of such cases: • The temperature of the medium is outside the limits specified for the pressure transmitter. • The medium is corrosive and requires diaphragm materials which are not available for the pressure transmitter. • The medium is highly viscous or contains solids which would Siemens FI 01 · 2009block the measuring chambers of the pressure transmitter. • The medium may freeze in the measuring chambers or pulse line. • The medium is heterogeneous or fibrous. • The medium tends towards polymerization or crystallization. • The process requires quick-release remote seals, as necessary e.g. in the food industry for fast cleaning. • The process requires cleaning of the measuring point, e.g. in a batch process. Diaphragm seal of sandwich design without (left) and with a projecting diaphragm (tube) • Sandwich design • Sandwich design with projecting diaphragm (tube) to DIN or ASME which are secured using a dummy flange. Diaphragm seal of flange design without (left) and with a projecting diaphragm (tube) • Flange design • Flange design with projecting diaphragm (tube) to DIN or ASME, secured using holes in the flange. ■ Design A remote seal system consists of the following components. • Pressure transmitter • One or two remote seals • Filling liquid • Connection between pressure transmitter and remote seal (direct mounting or by means of capillary) The volume in contact with the measured medium is terminated by a flat elastic diaphragm lying in a bed. Between the diaphragm and the pressure transmitter is the filling liquid. In many cases, a capillary has to be connected between the remote seal and the pressure transmitter in order e.g. to minimize temperature effects on the latter when hot media are involved. However, the capillary influences the response time and the temperature response of the complete remote seal system. Two 2/150 Siemens FI 01 · 2009 Quick-release diaphragm seal • Quick-release remote seals, e.g. to DIN 11851, SMS standard, IDF standard, APV RJT standard, clamp connection, etc. • Miniature diaphragm seal with male thread for screwing into tapped holes • Remote seals with customer-specific process connections © Siemens AG 2008 SITRANS P measuring instruments for pressure Remote seals for transmitters and pressure gages Technical description ■ Function The measured pressure is transferred from the diaphragm to the filling liquid and passes through the capillary to the measuring chamber of the pressure transmitter. The interior of the diaphragm seal and of the capillary, as well as the measuring chamber of the transmitter, are filled gas-free by the filling liquid. Transmission response Miniature diaphragm seal with diaphragm flush with front The transmission response of a remote seal is characterized by the following variables: • Temperature error • Adjustment time • Miniature diaphragm seals Temperature error The quick-release remote seals are used above all in the food industry. Their design means that the measured medium cannot accumulate in dead volumes. The quick-release clamp present on the remote seal means that quick dismounting is possible for cleaning. Temperature errors are caused by the change of volume of the filling liquid due to temperature variations. To select the right remote seal you must calculate the temperature error. Clamp-on seal Below you will find an overview of the factors which influence the size of the temperature error, as well as information on how to calculate the temperature error. The temperature error is dependent on the following variables: • Rigidity of the diaphragm used • Filling liquid used • Influence of the filling liquid underneath the process flanges or in the connection shank of the pressure transmitter • Internal diameter of the capillary: The bigger the internal diameter, the bigger the temperature error • Length of the capillary: The longer the capillary, the bigger the temperature error Diaphragm rigidity Clamp-on seal with quick-release design (left) and for flange mounting With clamp-on seals, the pressure is first measured using a cylindrical diaphragm positioned in a pipe, and then transmitted to the pressure transmitter by means of the filling liquid. The clamp-on seal is a special design for flowing media. It consists of a cylindrical pipe in which a cylindrical diaphragm is embedded. Since it is completely integrated in the process pipe, no turbulences, dead volumes or other obstructions to the flow occur. Furthermore, the clamp-on seal can be cleaned by a pig. The following types of clamp-on seals exist: • Quick-release clamp-on seals, e.g. to DIN 11851, SMS standard, IDF standard, APV/RJT standard, clamp connection etc. The quick-release facility attached to the remote seal enables the seal to be removed quickly for cleaning purposes. • Clamp-on seals for flanging to EN or ASME. • Clamp-on seals with customer-specific process connections. Note: The pressure data on the transmitter and the remote seal must be observed with regard to pressure/temperature behavior. The rigidity of the diaphragm is of decisive importance. The bigger the diameter of the diaphragm, the softer the diaphragm and the more sensitively it reacts to temperature-induced changes in volume of the filling liquid. The result is that small measuring ranges are only possible with large diaphragm diameters. Other factors apart from diaphragm rigidity which also play a role: • Diaphragm thickness • Diaphragm material • Coatings if present Filling liquid Every filling liquid reacts to temperature variations with a change of volume. Temperature errors can be minimized by selecting a suitable filling liquid, but the filling liquid must also be appropriate for the temperature limits and operating pressure. Furthermore, the filling liquid must also be physiologically harmless. Since the filling liquid is present under the diaphragm, in the capillary and under the process flange of the pressure transmitter (or in the connection shank), the temperature error must be calculated separately for each combination. Note: When operating in the low-pressure range, also during commissioning, it is recommended to use a vacuum-proof remote seal (see Selection and Ordering data). An example of a temperature error calculation can be found in the section "Technical Specifications". Siemens FI 01 · 2009 2/151 2 © Siemens AG 2008 SITRANS P measuring instruments for pressure Remote seals for transmitters and pressure gages Technical description Response time 2 The response time is dependent on the following factors: • Internal diameter of the capillary: The bigger the internal diameter, the shorter the response time • Viscosity of the filling liquid The greater the viscosity, the longer the response time • Length of the capillary: The longer the capillary, the longer the response time • Pressure in the pressure measuring system: The higher the pressure, the shorter the response time Recommendations The following should be observed to obtain an optimum combination of transmitter and remote seal: • Choose the biggest possible diameter for the remote seal. The effective diameter of the seal diaphragm is then bigger and the temperature error smaller. • Choose the shortest possible capillary. The response time is then shorter and the temperature error smaller • Choose the filling liquid with the least viscosity and the smallest coefficient of expansion. Make sure, however, that the filling liquid meets the process requirements with regard to pressure, vacuum and temperature. And ensure that the filling liquid and the medium are compatible with one another. • Note the following points for use in the vacuum range: - The pressure transmitter must always be positioned below the lowest spigot. - The operating range of some filling liquids is very limited with regard to the permissible temperature of the medium. - A vacuum-proof seal is necessary for continuous operation in the low-pressure range. • Recommendations for the minimum span can be found in the section "Technical data". Note The remote seals listed here are a selection of the most common designs. On account of the large variety of process connections, certain remote seals which are not listed here may be available nevertheless. Other versions can be: • Other process connections, standards • Aseptic or sterile connections • Other dimensions • Other nominal pressures • Special diaphragm materials, including coatings • Other sealing faces • Other filling liquids • Other capillary lengths • Sheathing of capillaries with protective hose • Calibration at higher/lower temperatures etc. Please contact your Siemens Regional Office for more information. 2/152 Siemens FI 01 · 2009 © Siemens AG 2008 SITRANS P measuring instruments for pressure Remote seals for transmitters and pressure gages Technical description ■ Technical specifications Temperature error Diaphragm seals Temperature errors of diaphragm seals when connected to pressure transmitters for pressure, absolute pressure, differential pressure (single-sided) and level Nominal diameter/ design Diaphragm diameter mm Sandwich design or with flange to EN 1092-1 Sandwich design or with flange to ASME B16.5 Temperature Temperature error of error of remote capillary seal (inch) mbar/ (psi/ 10 K 10 K) mbar/ (10 K ⋅ mKap) Temperature error of process flange/connection spigot (psi/ mbar/ (psi/ (10 K ⋅ mKap)) 10 K 10 K) Recommended min. spans (guidance values, observe temp. error) mbar (psi) DN 50 without tube 59 (2.32) 1.5 (0.022) 2 (0.029) 2 (0.029) 200 (2.90) DN 50 with tube 48 (1.89) 5 (0.073) 10 (0.145) 10 (0.145) 500 (7.25) DN 80 without tube 89 (3.50) 0.2 (0.003) 0.2 (0.003) 0.2 (0.003) 100 (1.45) DN 80 with tube 72 (2.83) 1 (0.015) 1 (1.015) 1 (1.015) 250 (3.63) DN 100 without tube 89 (3.50) 0.4 (0.006) 0.4 (0.006) 0.4 (0.006) 100 (1.45) DN 100 with tube 89 (3.50) 0.4 (0.006) 0.4 (0.006) 0.4 (0.006) 100 (1.45) DN 125 without tube 124 (4.88) 0.2 (0.003) 0.1 (0.002) 0.1 (0.002) 20 (0.29) DN 125 with tube 124 (4.88) 0.2 (0.003) 0.1 (0.002) 0.1 (0.002) 20 (0.29) 2 inch without tube 59 (2.32) 1.5 (0.022) 2 (0.029) 2 (0.029) 200 (2.90) 2 inch with tube 48 (1.89) 5 (0.073) 10 (0.145) 10 (0.145) 500 (7.25) 3 inch without tube 89 (3.50) 0.2 (0.003) 0.2 (0.003) 0.2 (0.003) 100 (1.45) 3 inch with tube 72 (2.83) 1 (0.015) 1 (1.015) 1 (1.015) 250 (3.63) 4 inch without tube 89 (3.50) 0.4 (0.006) 0.4 (0.006) 0.4 (0.006) 100 (1.45) 4 inch with tube 89 (3.50) 0.4 (0.006) 0.4 (0.006) 0.4 (0.006) 100 (1.45) 5 inch without tube 124 (4.88) 0.2 (0.003) 0.1 (0.002) 0.1 (0.002) 20 (0.29) 5 inch with tube 124 (4.88) 0.2 (0.003) 0.1 (0.002) 0.1 (0.002) 20 (0.29) Remote seal DN 25 with union nut to DN 32 DIN 11851 DN 40 25 (0.98) 20 (0.290) 60 (0.870) 60 (0.870) 6000 (87) 32 (1.26) 8 (0.116) 25 (0.363) 25 (0.363) 4000 (58) 40 (1.57) 4 (0.058) 10 (0.145) 10 (0.145) 2000 (29) DN 50 52 (2.05) 4 (0.058) 5 (0.073) 5 (0.073) 500 (7.25) DN 65 59 (2.32) 3 (0.044) 4 (0.058) 4 (0.058) 500 (7.25) DN 80 72 (2.83) 1 (0.015) 1 (0.015) 1 (0.015) 250 (3.63) DN 25 25 (0.98) 20 (0.290) 60 (0.870) 60 (0.870) 6000 (87) DN 32 32 (1.26) 8 (0.116) 25 (0.363) 25 (0.363) 4000 (58) DN 40 40 (1.57) 4 (0.058) 10 (0.145) 10 (0.145) 2000 (29) DN 50 52 (2.05) 4 (0.058) 5 (0.073) 5 (0.073) 500 (7.25) DN 65 59 (2.32) 3 (0.044) 4 (0.058) 4 (0.058) 500 (7.25) DN 80 72 (2.83) 1 (0.015) 1 (0.015) 1 (0.015) 250 (3.63) 32 (1.26) 8 (0.116) 25 (0.363) 25 (0.363) 4000 (58) 40 (1.57) 4 (0.058) 10 (0.145) 10 (0.145) 2000 (29) Remote seal with threaded socket to DIN 11851 Clamp connec- 1½ inch tion 2 inch Miniature diaphragm seal 2½ inch 59 (2.32) 3 (0.044) 5 (0.073) 5 (0.073) 500 (7.25) 3 inch 72 (2.83) 1 (0.015) 1 (0.015) 1 (0.015) 250 (3.63) G1B 25 (0.98) 20 (0.290) 60 (0.870) 60 (0.870) 6000 (87) G1½B 40 (1.57) 4 (0.058) 10 (0.145) 10 (0.145) 2000 (29) G2B 52 (2.05) 4 (0.058) 5 (0.073) 5 (0.073) 500 (7.25) Remarks: • Values apply for the filling liquids silicone oil M5, silicone oil M50, high-temperature oil, halocarbon oil and food oil (FDA listed). • Half the values apply to glycerin/water mixture as the filling liquid. • Values apply to stainless steel as the diaphragm material. Siemens FI 01 · 2009 2/153 2 © Siemens AG 2008 SITRANS P measuring instruments for pressure Remote seals for transmitters and pressure gages Technical description Temperature errors of diaphragm seals with connection to differential pressure transmitters (double-sided) Nominal diameter/ design Diaphragm diameter Temperature error Temperature error of cap- Temperature error of remote seal illary of process flange/connection spigot mm (inch) mbar/ 10 K (psi/ 10 K) DN 50 without tube 59 (2.32) 0.3 (0.0043) 0.3 (0.0045) DN 50 with tube 48 (1.89) 1.26 (0.018) 1.7 (0.025) DN 80 without tube 89 (3.50) 0.05 (0.001) 0.05 DN 80 with tube 72 (2.83) 0.24 (0.004) DN 100 without tube 89 (3.50) 0.1 DN 100 with tube 89 (3.50) 0.1 DN 125 without tube 124 (4.88) 0.05 2 Sandwich design or with flange to EN 1092-1 DN 125 with tube Sandwich 2 inch without tube design with flange to ASME 2 inch with tube B16.5 3 inch without tube (psi/ mbar/ mbar/ (10 K ⋅ mKap) (10 K ⋅ mKap)) 10 K Recommended min. spans (guidance values, observe temperature error) (psi/ 10 K) mbar (psi) 0.3 (0.0045) 250 (3.626) 1.7 (0.025) 250 (3.626) (0.001) 0.05 (0.0007) 50 (0.725) 0.17 (0.003) 0.17 (0.003) 100 (1.45) (0.002) 0.07 (0.001) 0.07 (0.001) 50 (0.725) (0.002) 0.07 (0.001) 0.07 (0.001) 50 (0.725) (0.001) 0.03 (0.0004) 0.03 (0.0004) 20 (0.29) 0.03 (0.29) 124 (4.88) 0.05 (0.001) (0.0004) 0.03 (0.0004) 20 59 (2.32) 0.3 (0.0043) 0.3 (0.0043) 0.3 (0.0045) 250 (3.626) 48 (1.89) 1.26 (0.018) 1.7 (0.025) 1.7 (0.025) 250 (3.626) 89 (3.50) 0.05 (0.001) 0.05 (0.0007) 0.05 (0.0007) 50 (0.725) 3 inch with tube 72 (2.83) 0.24 (0.004) 0.17 (0.003) 0.17 (0.003) 100 (1.45) 4 inch without tube 89 (3.50) 0.1 (0.002) 0.07 (0.001) 0.07 (0.001) 50 (0.725) 4 inch with tube 89 (3.50) 0.1 (0.002) 0.07 (0.001) 0.07 (0.001) 50 (0.725) 5 inch without tube 124 (4.88) 0.05 (0.001) 0.03 (0.0004) 0.03 (0.0004) 20 (0.29) 5 inch with tube 124 (4.88) 0.05 (0.001) 0.03 (0.0004) 0.03 (0.0004) 20 (0.29) Remote seal DN 50 with union nut to DN 65 DIN 11851 DN 80 52 (2.05) 1 (0.015) 0.83 (0.012) 0.83 (0.012) 250 (3.626) 59 (2.32) 0.7 (0.010) 0.67 (0.010) 0.67 (0.010) 250 (3.626) 72 (2.83) 0.24 (0.004) 0.17 (0.003) 0.17 (0.003) 100 (1.450) Remote seal with threaded socket to DIN 11851 DN 50 52 (2.05) 1 (0.015) 0.83 (0.012) 0.83 (0.012) 250 (3.626) DN 65 59 (2.32) 0.7 (0.010) 0.67 (0.010) 0.67 (0.010) 250 (3.626) DN 80 72 (2.83) 0.24 (0.004) 0.17 (0.003) 0.17 (0.003) 100 (1.450) 40 (1.57) 1 (0.015) 2.5 (0.036) 2.5 (0.036) 2000 (29.01) 59 (2.32) 0.7 (0.010) 0.67 (0.010) 0.67 (0.010) 250 (3.626) 72 (2.83) 0.24 (0.004) 0.17 (0.003) 0.17 (0.003) 100 (1.450) Clamp connec- 2 inch tion 2½ inch 3 inch Remarks: • Values apply for the filling liquids silicone oil M5, silicone oil M50, high-temperature oil, halocarbon oil and food oil (FDA listed) • Half the values apply to glycerin/water mixture as the filling liquid • Values apply to stainless steel as the diaphragm material. 2/154 Siemens FI 01 · 2009 © Siemens AG 2008 SITRANS P measuring instruments for pressure Remote seals for transmitters and pressure gages Technical description Temperature error Clamp-on seals Temperature errors of clamp-on seals when connected to pressure transmitters for pressure and absolute pressure, and with singlesided connection to pressure transmitters for differential pressure Nominal diameter/ design Temperature error of remote seal Temperature error of capillary Temperature error of process flange/connection spigot Recommended min. spans (guidance values, observe temperature error) mbar/10 K (psi/10 K) mbar/10 K (psi/10 K) mbar/10 K (psi/10 K) mbar (psi) DN 25 (1 inch) 6.0 (0.0870) 8.5 (0.123) 8.5 (0.123) 1000 (14.5) DN 40 (1½ inch) 4.5 (0.065) 4.5 (0.065) 4.5 (0.065) 250 (3.63) DN 50 (2 inch) 4.0 (0.058) 3.0 (0.044) 3.0 (0.044) 100 (1.45) DN 80 (3 inch) 9.5 (0.138) 5.0 (0.073) 5.0 (0.073) 100 (1.45) DN 100 (4 inch) 8.0 (0.012) 3.0 (0.044) 3.0 (0.044) 100 (1.45) Temperature errors of clamp-on seals with double-sided connection to pressure transmitters for differential pressure Nominal diameter/ design Temperature error of remote seal Temperature error of capillary Temperature error of process flange/connection spigot Recommended min. spans (guidance values, observe temperature error) mbar/10 K (psi/10 K) mbar/10 K (psi/10 K) mbar/10 K (psi/10 K) mbar (psi) DN 25 (1 inch) 2.3 (0.033) 1.8 (0.026) 1.8 (0.026) 1000 (14.5) DN 40 (1½ inch) 0.8 (0.012) 0.3 (0.004) 0.3 (0.004) 250 (3.63) DN 50 (2 inch) 0.3 (0.004) 0.1 (0.002) 0.1 (0.002) 100 (1.45) DN 80 (3 inch) 3.0 (0.044) 0.5 (0.007) 0.5 (0.007) 100 (1.45) DN 100 (4 inch) 1.0 (0.015) 0.1 (0.002) 0.1 (0.002) 100 (1.45) Remarks: • Values apply for the filling liquids silicone oil M5, silicone oil M50, high-temperature oil, halocarbon oil and food oil (FDA listed). • Half the values apply to glycerin/water mixture as the filling liquid. • Values apply to stainless steel as the diaphragm material. • Diaphragm thickness 0.05 mm (0.002 inch) for DN 25/DN 40/DN 50 and 0.1 mm (0.004 inch) for DN 80/DN 100 Siemens FI 01 · 2009 2/155 2 © Siemens AG 2008 SITRANS P measuring instruments for pressure Remote seals for transmitters and pressure gages Technical description Calculation of the temperature error Dependence of temperature error on diaphragm material The following equation is used to calculate the temperature error: The temperature errors listed in the previous table are based on the use of stainless steel as the diaphragm material. If other diaphragm materials are used, the temperature errors change as follows: dp = (ϑRS – ϑCal) ⋅ fRS + (ϑCap – ϑCal) ⋅ lCap ⋅fCap + (ϑTR – ϑCal) ⋅ fPF 2 dp Additional temperature error (mbar) ϑRS Temperature on remote seal diaphragm (generally corresponds to temperature of medium) ϑCal Calibration (reference) temperature (20 °C (68 °F)) fRS Temperature error of remote seal ϑCap Ambient temperature on the capillaries lCap Capillary length fCap Temperature error of capillaries ϑTR Ambient temperature on pressure transmitter fPF Temperature error of the oil filling in the process flanges of the pressure transmitter Example of temperature error calculation Existing conditions SITRANS P pressure transmitter for differential pressure, 250 mbar, set to 0 ... 100 mbar, with DN 80 remote seal diaphragms without tube, diaphragm made of stainless steel, mat. No. 1.4404/316L fRS = 0.1 mbar/10 K (0.0014 psi/10 K) Diaphragm material Change in temperature error of remote seal Stainless steel See previous tables Hastelloy C4, mat. No. 2.4610 50% Hastelloy C276, mat. No. 2.4819 50% Monel 400, mat. No. 2.4360 60% Increase in values by Tantalum 50% Titanium 50% PTFE coating on stainless steel diaphragm 80% ECTFE coating or PFA coating on stainless steel diaphragm 100% Gold coating on stainless steel diaphragm 40% Maximum temperature of medium Capillary length lCap = 6 m (19.7 ft) Capillaries fitted on both sides fCap = 0.07 mbar/(10 K ⋅ mCap) (0.001 psi/(10 K ⋅ mCap)) Filling liquid silicone M5 fPF = 0.07 mbar/10 K (0.001 psi/10 K) Process temperature The following maximum temperatures of the medium apply depending on the material of the wetted parts: Material pabs < 1 bar (14.5 psi) pabs > 1 bar (14.5 psi) °C (°F) °C (°F) ϑRS = 100 °C (212 °F) Stainless steel, 316L 200 (392) 400 (662) Temperature on the capillaries ϑCap = 50 °C (122 °F) PTFE coating 200 (392) 260 (500) Temperature on pressure transmitter ϑTR = 50 °C (122 °F) ECTFE coating 100 (212) 150 (302) PFA coating 200 (392) 260 (500) Calibration temperature ϑCal = 20 °C (68 °F) Required Additional temperature error of remote seals dp Calculation Hastelloy C4, mat. No. 2.4610 200 (392) 260 (500) Hastelloy C276, mat. No. 2.4819 200 (392) 400 (662) Monel 400, mat. No. 2.4360 200 (392) 400 (662) Tantalum 200 (392) 300 (572) Maximum capillary length for diaphragm seals (guidance values) in mbar dp = (100 °C – 20 °C) ⋅ 0.1 mbar/10 K + (50 °C – 20 °C) ⋅ 6 m ⋅ 0.07 mbar/(10 K ⋅ m) + (50 °C – 20 °C) ⋅ 0.07 mbar/10 K Nom. diam. Max. length of capillary Diaphragm seal dp = 0.8 mbar + 1.26 mbar + 0.21 mbar m (ft) DN 25 (1 inch) 2.5 (8.2) 2.5 (8.2) dp = (212 °F – 68 °F) ⋅ 0.0014 psi/10 K + (112 °F – 68 °F) ⋅ 19.7 ft ⋅ 0.001 psi/(10 K ⋅ 3.28 ft) + (112 °F – 68 °F) ⋅ (0.001 psi/10 K) DN 32 (1¼ inch) 2.5 (8.2) 2.5 (8.2) Result dp = 2.27 mbar (0.033 psi) (corresponds to 2.27% of set span) Note The determined temperature error only applies to the error resulting from connection of the remote seal. The transmission response of the respective transmitter is not included in this consideration. It must be calculated separately, and the resulting error added to the error determined above from connection of the remote seal. 2/156 Siemens FI 01 · 2009 (ft) Clamp-on seal in psi dp = 0.012 psi + 0.018 psi + 0.003 psi m DN 40 (1½ inch) 4 (13.1) 6 (19.7) DN 50 (2 inch) 6 (19.7) 10 (32.8) DN 65 (2½ inch) 8 (26.2) 10 (32.8) DN 80 (3 inch) 10 (32.8) 10 (32.8) DN 100 (4 inch) 10 (32.8) 10 (32.8) DN 125 (5 inch) 10 (32.8) - - © Siemens AG 2008 SITRANS P measuring instruments for pressure Remote seals for transmitters and pressure gages Technical description Response times The values listed in the following table are the response times (in seconds per meter of capillary) for a change in pressure which corresponds to the set span. The response times are independent of the set span within the range of the respective transmitter. The response times are of insignificant importance for spans above 10 bar (145 psi). The response times of the pressure transmitters are not considered in the table. The listed values must be multiplied by the respective length of the capillary, or with transmitters for differential pressure and flow by the total length of both capillaries. Filling liquid Density Silicone oil M5 Silicone oil M50 Halocarbon oil Glycerin/water Response time in s/m (s/ft) with max. span of pressure transmitter (lb/in3) °C (°F) 250 mbar (3.63 psi) 600 mbar (8.7 psi) 1600 mbar (23.2 psi) 0.914 (0.033) +60 (140) 0.06 (0.018) 0.02 (0.006) 0.01 (0.003) +20 (68) 0.11 (0.034) 0.02 (0.006) 0.02 (0.006) - 20 (-4) 0.3 (0.091) 0.12 (0.037) 0.05 (0.015) +60 (140) 0.6 (0.183) 0.25 (0.076) 0.09 (0.027) +20 (68) 0.61 (0.186) 0.26 (0.079) 0.1 (0.030) - 20 (-4) 1.69 (0.515) 0.71 (0.216) 0.27 (0.082) +60 (140) 0.14 (0.043) 0.06 (0.018) 0.02 (0.006) 1.070 1.968 Food oil (FDA listed) Temperature on capillary kg/dm3 0.966 High-temperature oil 0.920 1.220 (0.035) (0.039) (0.071) (0.033) (0.044) +20 (68) 0.65 (0.198) 0.27 (0.082) 0.1 (0.030) -10 (14) 3.96 (1.207) 1.65 (0.503) 0.62 (0.189) +60 (140) 0.07 (0.021) 0.03 (0.009) 0.01 (0.003) +20 (68) 0.29 (0.088) 0.12 (0.037) 0.05 (0.015) - 20 (-4) 2.88 (0.878) 1.2 (0.366) 0.45 (0.137) +60 (140) 0.75 (0.229) 0.33 (0.101) 0.17 (0.052) +20 (68) 4 (1.220) 1.75 (0.534) 0.67 (0.204) - 20 (-4) 20 (6.100) 8.5 (2.593) 3.25 (0.991) +60 (140) 0.13 (0.040) 0.05 (0.015) 0.02 (0.006) +20 (68) 0.76 (0.232) 0.32 (0.098) 0.12 (0.037) 0 (32) 9.72 (2.963) 4.05 (1.234) 1.51 (0.460) Technical data of filling liquids When selecting the filling liquid, check that it is suitable with respect to the permissible temperature of the medium and the process pressure. Filling liquid 2 Also check the compatibility of the filling liquid with the measured medium. For example, only physiologically harmless filling liquids may be used in the food industry. Oxygen and chlorine are special cases of measured medium. The liquid must not react with either of these two media or a leaking remote seal may lead to an explosion or fire. Digit in Permissible temperature of medium Order No. Density at 20 °C (68 °F) pabs < 1 bar (pabs < 14.5 psi) pabs > 1 bar (pabs > 14.5 psi) °C (°F) °C (°F) (-76 ... +176) -90 ... +180 (-130 ... +356) 0.914 Viscosity at 20 °C (68 °F) Coefficient of expansion kg/dm3 (lb/in3) m2/s⋅106 (ft2/s⋅106) 1/°C (1/°F) Silicone oil M5 1 -60 ... +80 (0.03) 4 (43) 0.00108 Silicone oil M50 2 -40 ... +150 (-40 ... +302) -40 ... +250 (-40 ... +482) 0.96 (0.03) 50 (538) 0.00104 (0.00058) High-temperature oil 3 -10 ... +200 (+14 ... +392) -10 ... +350 (+14 ... +662) 1.07 (0.04) 39 (420) 0.00080 (0.00044) Halocarbon oil 4 -40 ... +80 (-40 ... +176) -40 ... +175 (-40 ... +347) Glycerin/water 6 Not possible Not possible Food oil (FDA listed) 7 -20 ... +160 (-4 ... +320) 1.968 (0.00060) (0.07) 14 (151) 0.00086 (0.00048) -10 ... +120 (+14 ... +248) 1.22 (0.04) 88 (947) 0.00050 (0.00028) -20 ... +200 (-4 ... +392) (0.03) 10 (107) 0.00080 (0.00044) 0.92 Siemens FI 01 · 2009 2/157 © Siemens AG 2008 SITRANS P measuring instruments for pressure Diaphragm seals of sandwich design For gage, absolute, differential pressure and flow with flexible capillary ■ Overview 2 Diaphragm seals of sandwich design ■ Technical specifications Diaphragm seals of sandwich design Maximum pressure See above and the technical data of the pressure transmitters Tube length Without tube as standard (tube available on request) Nominal diameter Nominal pressure • DN 50 PN 16 ... PN 100 • DN 80 PN 16 ... PN 100 Capillary • DN 100 PN 16 ... PN 100 • Length • DN 125 PN 16 ... PN 100 • 2 inch Class 150 ... class 2500 • Internal diameter max. 2 mm (0.079 inch) • 3 inch Class 150 ... class 2500 • Minimum bending radius 150 mm (5.9 inch) • 4 inch Class 150 ... class 2500 Filling liquid • 5 inch Class 150 ... class 2500 Max. 10 m (32.8 ft), longer lengths on request Silicone oil M5 Silicone oil M50 High-temperature oil Sealing face Halocarbon oil (for measuring O2) • For stainless steel, mat. No. 1.4404/216L To EN 1092-1, form B1 or ASME B16.5 RF 125 ... 250 AA Food oil (FDA listed) • For the other materials To EN 1092-1, form B2 or ASME B16.5 RFSF Glycerine/water (not suitable for use in low-pressure range) Permissible ambient temperature Dependent on the pressure transmitter and the filling liquid of the remote seal More information can be found in the technical data of the pressure transmitters and in the section "Technical data of filling liquid" in the Technical description to the remote seals • PFA (for vacuum on request) Weight Approx. 4 kg (8.82 lb) Monel 400, mat. No. 2.4360 Certificate and approvals Hastelloy C276, mat. No. 2.4819 Classification according to pressure equipment directive (DRGL 97/23/EC) Materials • Main body Stainless steel 316L • Wetted parts Stainless steel 316L • Without foil • PTFE (for vacuum on request) • ECTFE (for vacuum on request) Hastelloy C4, mat. No. 2.4610 Tantalum • Capillary Stainless steel, mat. No. 1.4571/316Ti • Sheath Spiral hose made of stainless steel, mat. No. 1.4301/316 Sealing material in the process flanges • For pressure transmitters, absolute pressure transmitters and lowpressure applications Copper • For other applications Viton 2/158 Siemens FI 01 · 2009 For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of article 3, paragraph 3 (sound engineering practice) © Siemens AG 2008 SITRANS P measuring instruments for pressure Diaphragm seals of sandwich design For gage, absolute, differential pressure and flow with flexible capillary Selection and Ordering data Order No. Ord.code Order No. Ord.code Selection and Ordering data Diaphragm seal Diaphragm seal Sandwich-type design, with flexible capillary connected to a SITRANS P transmitter (order separately): for pressure 7MF4037 and 7MF4237 together D) 7 M F 4 9 0 0 with Order code "V01" (vacuum-proof design) and 7MF80271); Scope of delivery (1 off) Sandwich-type design, with flexible capillary connected to a SITRANS P transmitter (order separately): for pressure 7MF4037 and 7MF4237 together D) 7 M F 4 9 0 0 with Order code "V01" (vacuum-proof design) and 7MF80271); Scope of delivery (1 off) for absolute pressure 7MF433 7; Scope of delivery (1 off) D) 7 M F 4 9 0 1 - D) 7 M F 4 9 0 1 - for absolute pressure 7MF433 7; Scope of delivery (1 off) for differential pressure and flow 7MF443 7; D) 7 M F 4 9 0 3 scope of delivery 2 off for differential pressure and flow 7MF443 7; D) 7 M F 4 9 0 3 scope of delivery 2 off 1 7777 - 7B 777 Nominal diameter and nominal pressure • DN 50 PN 16 ... 100 (recommended only for pressure transmitters for pressure) • DN 80 PN 16 ... 100 • DN 100 PN 16 ... 100 • DN 125 PN 16 ... 100 • 2 inch Class 150 ... 2500 (recommended only for pressure transmitters for pressure) • 3 inch Class 150 ... 2500 • 4 inch Class 150 ... 2500 • 5 inch Class 150 ... 2500 Smooth sealing face to EN 1092-1, form B1 or to ASME B16.5 RF 125 ... 250 AA Other version Add Order code and plain text: Nominal diameter: ...; Nominal pressure: ... Sealing face: see "Technical data" Wetted parts materials • Stainless steel 316L - without foil - with PTFE coating - with ECTFE coating2) - with PFA coating • Monel 400, mat. No. 2.4360 • Hastelloy C276, mat. No. 2.4819 • Hastelloy C4, mat. No. 2.4610 • Tantalum Other version Add Order code and plain text: Wetted parts materials: ... Tube length • without tube Other version: Add Order code and plain text: Tube length: ... Filling liquid • Silicone oil M5 • Silicone oil M50 • High-temperature oil • Halocarbon oil (for measuring O2) • Glycerin/water3) • Food oil (FDA listed)l Other version Add Order code and plain text: Filling liquid: ... 1) 2) 3) 2 1 7777 - 7B 777 Length of capillary2) • 1.0 m (3.28 ft) • 1.6 m (5.25 ft) • 2.5 m (8.20 ft) • 4.0 m (13.1 ft) • 6.0 m (19.7 ft) • 8.0 m (26.25 ft) • 10.0 m (32.8 ft) Other version Add Order code and plain text: Length of capillary: ... A B C D E H L N 2 3 4 5 6 7 8 9 N1Y 1) With 7MF8027 and the measuring cells Q, S, T and U also order the vacuum-tight version. Max. capillary length, see section "Technical description". D) Subject to export regulations AL: N, ECCN: EAR99H. 2) Z J1Y Order code Selection and Ordering data Further designs Please add "-Z" to Order No. and specify Order code. Spark arrestor With spark arrestor for mounting on zone 0 (including documentation) • Pressure and absolute pressure • for differential pressure transmitters A E0 F D G J U K Z K1Y 0 9 L1Y 1 2 3 4 6 7 9 A01 A02 Quality inspection certificate (Factory calibration) to IEC 60770-2 C11 Acceptance test certificate to EN 10204, section 3.1 C12 Vacuum-proof design for use in low-pressure range for transmitters for • Pressure • For differential pressure transmitters Calculation of span of associated pressure transmitter Enclose filled-in questionnaire with order V01 V03 Y05 M1 Y With 7MF8027 and the measuring cells Q, S, T and U also order the vacuum-tight version. For vacuum on request Not suitable for use in low-pressure range. Siemens FI 01 · 2009 2/159 © Siemens AG 2008 SITRANS P measuring instruments for pressure Diaphragm seals of sandwich design For gage, absolute, differential pressure and flow with flexible capillary ■ Dimensional drawings 2 D dM D dM b b _ R ³ (5. 150 9) R ³ (5. 150 9) l l + Connection to EN 1092-1 Nom. diam. Nom. press. b D dM l mm mm mm mm Connection to EN 1092-1 Nom. diam. Nom. press. b D dM l DN 50 PN 16 ... PN 100 20 102 59 100 DN 80 20 138 89 100 mm mm mm DN 100 20 158 89 100 DN 50 PN 16 ... PN 100 20 102 59 100 DN 125 22 188 124 100 DN 80 20 138 89 100 DN 100 20 158 89 100 DN 125 22 188 124 100 Connection to ASME B16.5 Nom. diam. 2 inch mm Nom. press. b D dM I lb/sq.in. mm mm mm mm Connection to ASME B16.5 (inch) (inch) (inch) (inch) Nom. diam. 150 .... 2500 20 100 59 100 (0.79) (3.94) (2.32) (3.94) 20 134 89 100 3 inch (0.79) 4 inch 5 inch (5.28) (2.32) 2 inch (3.94) 20 158 89 100 (0.79) (6.22) (2.32) (3.94) 22 186 124 100 (0.87) (7.32) (4.88) (3.94) 3 inch 4 inch D dM mm mm mm mm (inch) (inch) (inch) (inch) 100 150 ... 2500 20 100 59 (0.79) (3.94) (2.32) (3.94) 20 134 89 100 (0.79) (5.28) (2.32) (3.94) 20 158 89 100 (0.79) (6.22) (2.32) (3.94) 22 186 124 100 (0.87) (7.32) (4.88) (3.94) d: Inside diameter of gasket according to EN 1092-1 / ASME B16.5 5 inch dM: Effective diaphragm diameter d: Inside diameter of gasket according to EN 1092-1 / ASME B16.5 Diaphragm seals of sandwich design with flexible capillary for connection to SITRANS P pressure transmitters for pressure, dimensions in mm (inch) I Nom. press. b lb/sq.in. dM: Effective diaphragm diameter Diaphragm seals of sandwich design (without flange) with flexible capillary for connection to SITRANS P pressure transmitters for absolute pressure or differential pressure and flow, dimensions in mm (inch) 2/160 Siemens FI 01 · 2009 © Siemens AG 2008 SITRANS P measuring instruments for pressure Diaphragm seals of flange design For gage, absolute, differential pressure and flow with flexible capillary ■ Overview 2 Diaphragm seals of flange design ■ Technical specifications Diaphragm seals of flange design with flexible capillary Sealing material in the process flanges Nominal diameter Nominal pressure • DN 50 (recommendable only for pressure transmitters for pressure) PN 10 ... PN 40, PN 100 • For pressure transmitters, absolute pressure transmitters and lowpressure applications Copper • DN 80 PN 10 ... PN 40, PN 100 • For other applications Viton • DN 100 PN 16, PN 40 Maximum pressure • DN 125 PN 16, PN 40 See above and the technical data of the pressure transmitter • 2 inch (recommendable only for pressure transmitters for pressure) Class 150, class 300, class 600, class 1500 Tube length Without tube as standard (tube available on request) • 3 inch Class 150, class 300, class 600 Capillary • 4 inch Class 150, class 300, class 400 • Length • 5 inch Class 150, class 300, class 400 Sealing face • For stainless steel, mat. No. 1.4404/316L To EN 1092-1, form B1 or ASMR B16.5 RF 125 ... 250 AA • For the other materials To EN 1092-1, form B2 or ASME B16.5 RFSF • Internal diameter 2 mm (0.079 inch) • Minimum bending radius 150 mm (5.9 inch) Filling liquid (for remote seals of sandwich and flange design) High-temperature oil • Main body Stainless steel 316L • Wetted parts Stainless steel 316L Halocarbon oil (for measuring O2) Food oil (FDA listed) • Without foil Glycerine/water (not for use in low-pressure range) • PTFE (for vacuum on request) • ECTFE (for vacuum on request) Permissible ambient temperature Dependent on the pressure transmitter and the filling liquid of the remote seal More information can be found in the technical data of the pressure transmitters and in the section "Technical data of filling liquid" in the Technical description to the remote seals Weight Approx. 4 kg (8.82 lb) • PFA (for vacuum on request) Monel 400, mat. No. 2.4360 Hastelloy C276, mat. No. 2.4819 Hastelloy C4, mat. No. 2.4610 Tantalum • Sheath Silicone oil M5 Silicone oil M50 Materials • Capillary Max. 10 m (32.8 ft), longer lengths on request Stainless steel, mat. No. 1.4571/316Ti Spiral hose made of stainless steel, mat. No. 1.4404/316L Certificate and approvals Classification according to pressure equipment directive (DRGL 97/23/EC) For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of article 3, paragraph 3 (sound engineering practice) Siemens FI 01 · 2009 2/161 © Siemens AG 2008 SITRANS P measuring instruments for pressure Diaphragm seals of flange design For gage, absolute, differential pressure and flow with flexible capillary Selection and Ordering data 2 Order No. Ord. code Order No. Ord. code Selection and Ordering data Diaphragm seal Diaphragm seal Flange design, with flexible capillary, connected to a pressure transmitter SITRANS P (order separately): Flange design, with flexible capillary, connected to a pressure transmitter SITRANS P (order separately): for pressure 7MF403 7 and 7MF4237 together D) 7 M F 4 9 2 0 with Order code "V01" (vacuum-proof design) and 7MF80271); scope of delivery: 1 off for pressure 7MF403 7 and 7MF4237 together D) 7 M F 4 9 2 0 with Order code "V01" (vacuum-proof design) and 7MF80271); scope of delivery: 1 off for absolute pressure 7MF433 7; scope of delivery: 1 off D) 7 M F 4 9 2 1 - for absolute pressure 7MF433 7; scope of delivery: 1 off for differential pressure and flow 7MF443 7; D) 7 M F 4 9 2 3 scope of delivery: 2 off D) 7 M F 4 9 2 1 - for differential pressure and flow 7MF443 7; D) 7 M F 4 9 2 3 scope of delivery: 2 off 1 7777 - 7B 777 Nominal diameter and nominal pressure • DN 50 PN 10 ... 40 PN 100 (DN 50 recommended only for pressure transmitters for pressure) PN 10 ... 40 PN 100 D E • DN 100 PN 16 PN 40 G H • DN 125 PN 16 PN 40 J K Class 150 Class 300 Class 600 Class 1500 (2 inch recommended only for pressure transmitters for pressure) • 3 inch Class 150 Class 300 Class 600 L M N P • 4 inch T U V • 2 inch Class 150 Class 300 Class 400 W X Y Other version Add Order code and plain text: Nominal diameter: ...; Nominal pressure: ... Sealing face: See "Technical data" Z Wetted parts materials • Stainless steel 316L - without foil - with PTFE coating - with ECTFE coating2) - with PFA coating • Monel 400, mat. No. 2.4360 • Hastelloy C276, mat. No. 2.4819 • Hastelloy C4, mat. No. 2.4610 • Tantalum Other version Add Order code and plain text: Wetted parts materials: ... Tube length • without tube Other version: Add Order code and plain text: Tube length: ... 2/162 Siemens FI 01 · 2009 Length of capillary4) • 1.0 m (3.28 ft) • 1.6 m (5.25 ft) • 2.5 m (8.20 ft) • 4.0 m (13.1 ft) • 6.0 m (19.7 ft) • 8.0 m (26.25 ft) • 10.0 m (32.8 ft) Other version Add Order code and plain text: Length of capillary: ... Q R S Class 150 Class 300 Class 400 Smooth sealing face to EN 1092-1, form B1 or to ASME B16.5 RF 125 ... 250 AA • 5 inch Filling liquid • Silicone oil M5 • Silicone oil M50 • High-temperature oil • Halocarbon oil (for measuring O2) • Glycerin/water3) • Food oil (FDA listed) Other version Add Order code and plain text: Filling liquid: ... A B • DN 80 1 7777 - 7B 777 1 2 3 4 6 7 9 M1 Y 2 3 4 5 6 7 8 9 N1Y 1) With 7MF8027 and the measuring cells Q, S, T and U also order the vacuum-tight version. For vacuum on request. 3) Not suitable for use in low-pressure range. 4) Max. capillary length, see section "Technical description". D) Subject to export regulations AL: N, ECCN: EAR99H. 2) Selection and Ordering data J1Y Spark arrestor With spark arrestor for mounting on zone 0 (including documentation) for transmitters for • pressure and absolute pressure • differential pressure A E0 F D G J U K Z K1Y 0 9 L1Y Order code Further designs Please add "-Z" to Order No. and specify Order code. A01 A02 Quality inspection certificate (Factory calibration) to IEC 60770-2 C11 Acceptance test certificate to EN 10204, section 3.1 C12 Vacuum-proof design for use in low-pressure range for transmitters for • pressure • differential pressure Calculation of span of associated pressure transmitter Enclose filled-in questionnaire with order V01 V03 Y05 © Siemens AG 2008 SITRANS P measuring instruments for pressure Diaphragm seals of flange design For gage, absolute, differential pressure and flow with flexible capillary ■ Dimensional drawings D 2 ) n xd 2 _ ³1 R ø d4 ø k ø d4 ø k 50 n xd 2 b f dM dM (5. 9 D b f R ³1 50 R ³ (5. 150 9) (5. 9) + Connection to EN 1092-1 Nom. diam. Nom. press. DN 50 PN 40 PN 100 DN 80 PN 40 PN 100 DN 100 PN 16 PN 40 DN 125 PN 16 PN 40 Connection to EN 1092-1 b mm D mm d2 mm d4 mm dM mm f mm k mm n Nom. diam. 20 28 24 32 20 24 22 26 165 195 200 230 220 235 250 270 18 26 18 26 18 22 18 26 102 102 138 138 158 162 188 188 59 59 89 89 89 89 124 124 2 2 2 2 2 2 2 2 125 145 160 180 180 190 210 220 4 4 8 8 8 8 8 8 DN 80 2 inch 3 inch 4 inch 5 inch Nom. press. b lb/sq.in. mm (inch) 150 20 (0.79) 300 22.5 (0.89) 600 32 (1.26) 150 24 (0.96) 300 29 (1.14) 400 38.5 (1.52) 150 24 (0.95) 300 32 (1.26) 400 41.5 (1.62) 150 24 (0.94) 300 35 (1.38) 400 45.5 (1.79) PN 40 PN 100 DN 100 PN 16 PN 40 DN 125 PN 16 PN 40 D d2 d4 dM f k mm (inch) 150 (5.80) 165 (6.50) 165 (6.50) 190 (7.48) 210 (8.27) 210 (8.27) 230 (9.06) 255 (10.04) 255 (10.04) 255 (10.04) 280 (11.02) 280 (11.02) mm (inch) 20 (0.79) 20 (0.79) 20 (0.79) 20 (0.79) 22 (0.87) 22 (0.87) 20 (0.79) 22 (0.87) 26 (1.02) 22 (0.87) 22 (0.87) 26 (1.02) mm (inch) 92 (3.62) 92 (3.62) 92 (3.62) 127 (5) 127 (5) 127 (5) 158 (6.22) 158 (6.22) 158 (6.22) 186 (7.32) 186 (7.32) 186 (7.32) mm (inch) 59 (2.32) 59 (2.32) 59 (2.32) 89 (3.50) 89 (3.50) 89 (3.50) 89 (3.50) 89 (3.50) 89 (3.50) 124 (4.88) 124 (4.88) 124 (4.88) mm (inch) 1.6 (0.06) 1.6 (0.06) 1.6 (0.06) 1.6 (0.06) 1.6 (0.06) 6.4 (0.25) 1.6 (0.06) 1.6 (0.06) 6.4 (0.25) 2 (0.08) 2 (0.08) 7 (0.28) mm (inch) 120.5 (4.74) 127 (5) 127 (5) 152.5 (6) 168.5 (6.63) 168.5 (6.63) 190.5 (7.5) 200 (7.87) 200 (7.87) 216 (8.50) 235 (9.25) 235 (9.25) n 4 8 8 4 8 8 4 8 8 4 8 b mm D mm d2 mm d4 mm dM mm f mm k mm n 24 32 20 24 22 26 200 230 220 235 250 270 18 26 18 22 18 26 138 138 158 162 188 188 89 89 89 89 124 124 2 2 2 2 2 2 160 180 180 190 210 220 8 8 8 8 8 8 Connection to ASME B16.5 Nom. Nom. diam. press. Connection to ASME B16.5 Nom. diam. Nom. press. b lb/sq.in. mm (inch) 3 inch 150 24 (0.96) 300 29 (1.14) 600 38.5 (1.52) 4 inch 150 24 (0.95) 300 32 (1.26) 400 41.5 (1.62) 5 inch 150 24 (0.94) 300 35 (1.38) 400 45.5 (1.79) D d2 d4 dM f k mm (inch) 190 (7.48) 210 (8.27) 210 (8.27) 230 (9.06) 255 (10.04) 255 (10.04) 255 (10.04) 280 (11.02) 280 (11.02) mm (inch) 20 (0.79) 22 (0.87) 22 (0.87) 20 (0.79) 22 (0.87) 26 (1.02) 22 (0.87) 22 (0.87) 26 (1.02) mm (inch) 127 (5) 127 (5) 127 (5) 158 (6.22) 158 (6.22) 158 (6.22) 186 (7.32) 186 (7.32) 186 (7.32) mm (inch) 89 (3.50) 89 (3.50) 89 (3.50) 89 (3.50) 89 (3.50) 89 (3.50) 124 (4.88) 124 (4.88) 124 (4.88) mm (inch) 1.6 (0.06) 1.6 (0.06) 6.4 (0.25) 1.6 (0.06) 1.6 (0.06) 6.4 (0.25) 2 (0.08) 2 (0.08) 7 (0.28) mm (inch) 152.5 (6) 168.5 (6.63) 168.5 (6.63) 190.5 (7.5) 200 (7.87) 200 (7.87) 216 (8.50) 235 (9.25) 235 (9.25) n 4 8 8 4 8 8 4 8 8 d: Inside diameter of gasket according to EN 1092-1 / ASME B16.5 dM: Effective diaphragm diameter Diaphragm seals of flange design with flexible capillary for connection to SITRANS P pressure transmitters for absolute pressure or for differential pressure and flow, dimensions in mm (inch) 8 d: Inside diameter of gasket according to EN 1092-1 / ASME B16.5 dM: Effective diaphragm diameter Diaphragm seals of flange design with flexible capillary for connection to SITRANS P pressure transmitters for pressure, dimensions in mm (inch) Siemens FI 01 · 2009 2/163 © Siemens AG 2008 SITRANS P measuring instruments for pressure Diaphragm seals of flange design For gage and absolute pressure, directly fitted on transmitter ■ Overview 2 Diaphragm seals of flange design, directly fitted on a pressure transmitter for pressure ■ Technical specifications Diaphragm seals (flange design) for pressure and absolute pressure, directly fitted on a transmitter Capillary • Length Max. 10 m (32.8 ft), longer lengths on request PN 40, PN 100 • Internal diameter 2 mm (0.079 inch) PN 40, PN 100 • Minimum bending radius 150 mm (5.9 inch) • DN 100 PN 16, PN 40 Filling liquid • 2 inch Class 150, class 300, class 600, class 1500 • 3 inch Class 150, class 300, class 600 • 4 inch Class 150, class 300, class 400 • Silicone oil M5 • Silicone oil M50 • High-temperature oil • Halocarbon oil (for measuring O 2) • Food oil (FDA listed) • Glycerine/water (not suitable for use in low-pressure range) Max. recommended process temperature 170 °C (338 °F) Permissible ambient temperature Dependent on the pressure transmitter and the filling liquid of the remote seal. More information can be found in the technical data of the pressure transmitters and in the section "Technical data of filling liquid" in the Technical description to the remote seals. Weight Approx. 4 kg (8.82 lb) Nominal diameter Nominal pressure • DN 50 • DN 80 Sealing face • For stainless steel, mat. No. 1.4404/316L To EN 1092-1, form B1 or ASME B16.5 RF 125 ... 250 AA • For the other materials Smooth to EN 1092-1, form B2 or ASME B16.5 RFSF Materials • Main body Stainless steel 316L • Wetted parts Stainless steel 316L • Without foil • PTFE (for vacuum on request) • ECTFE (for vacuum on request) • PFA (for vacuum on request) Monel 400, mat. No. 2.4360 Hastelloy C276, mat. No. 2.4819 Hastelloy C4, mat. No. 2.4610 Tantalum • Capillary Stainless steel, 1.4571/316Ti • Sealing material on the process connection Copper Maximum pressure See above and the technical data of the transmitter Tube length • Without tube • 50 mm (1.97 inch) • 100 mm (3.94 inch) • 150 mm (5.91 inch) • 200 mm (7.87 inch) 2/164 Siemens FI 01 · 2009 Certificate and approvals Classification according to pressure equipment directive (DRGL 97/23/EC) For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of article 3, paragraph 3 (sound engineering practice) © Siemens AG 2008 SITRANS P measuring instruments for pressure Diaphragm seals of flange design For gage and absolute pressure, directly fitted on transmitter Selection and Ordering data Order No. Ord.code D) 7 M F 4 9 1 0 - Diaphragm seal Directly fitted to a pressure transmitter SITRANS P for pressure 7MF403 7 and 7MF4237 together with Order code "V01" (vacuum-proof design) and 7MF80271); must be ordered separately 77777 Process connection • Vertical (pressure transmitter upright) 0 • Horizontal 2 Nominal diameter and nominal pressure • DN 50 PN 40 PN 100 PN 40 PN 100 D E • DN 100 PN 16 PN 40 G H D) 7 M F 4 9 1 0 - Diaphragm seal 777 Directly fitted to a pressure transmitter SITRANS P for pressure 7MF403 7 and 7MF4237 together with Order code "V01" (vacuum-proof design) and 7MF80271); must be ordered separately 77777 Filling liquid • Silicone oil M5 • Silicone oil M50 • High-temperature oil • Halocarbon oil (for measuring O2) • Glycerin/water3) • Food oil (FDA listed) Other version Add Order code and plain text: Filling liquid: ... A B • DN 80 Order No. Ord.code Selection and Ordering data 777 2 1 2 3 4 6 7 9 M1 Y 1) With 7MF8027 and the measuring cells Q, S, T and U also order the vacuum-tight version. For vacuum on request. 3) Not suitable for use in low-pressure range. D) Subject to export regulations AL: N, ECCN: EAR99H. 2) • 2 inch Class 150 Class 300 Class 600 Class 1500 L M N P • 3 inch Class 150 Class 300 Class 600 Q R S Selection and Ordering data • 4 inch Class 150 Class 300 Class 400 Smooth sealing face to DIN 1092-01, form B1 or B2, or to ASME B16.5 125 ... 250 AA or RFSF T U V Spark arrestor With spark arrestor for mounting on zone 0 (including documentation) for transmitters for pressure and absolute pressure A01 Z Quality inspection certificate (Factory calibration) to IEC 60770-2 to IEC 60770-2 C11 Other version Add Order code and plain text: Nominal diameter: ...; Nominal pressure: ... Acceptance test certificate to EN 10204, section 3.1 C12 Vacuum-proof design for use in low-pressure range for transmitters for pressure V01 Calculation of span of associated pressure transmitter Enclose filled-in questionnaire with order Y05 Wetted parts materials • Stainless steel 316L - without foil - with PTFE coating - with ECTFE coating2) - with PFA coating • Monel 400, mat. No. 2.4360 • Hastelloy C276, mat. No. 2.4819 • Hastelloy C4, mat. No. 2.4610 • Tantalum Other version Add Order code and plain text: Wetted parts materials: ... Tube length • Without tube • 50 mm • (1.97 inch) • 100 mm • (3.94 inch) • 150 mm • (5.90 inch) • 200 mm • (7.87 inch) Other version: Add Order code and plain text: Tube length: ... Order code Further designs Please add "-Z" to Order No. and specify Order code. J1Y A E0 F D G J U K Z K1Y 0 1 2 3 4 9 L1Y Siemens FI 01 · 2009 2/165 © Siemens AG 2008 SITRANS P measuring instruments for pressure Diaphragm seals of flange design For gage and absolute pressure, directly fitted on transmitter ■ Dimensional drawings Connection to EN 1092-1 Nom. diam. Nom. press. b D DN 50 PN 40 mm mm mm 20 165 18 PN 100 28 195 26 102 Vertical process connection 193 (7.6) 2 83 (3.27) DN 80 f L b n x d2 f 193 (7.6) b mm mm n mm mm mm 102 48.3 59 2 125 4 48.3 59 2 145 4 18 138 76 89 2 160 8 26 138 76 89 2 180 8 DN 100 PN 16 20 220 18 158 94 89 2 180 8 PN 40 24 235 22 162 94 89 2 190 8 300 ø d5 ø d4 øk øD k 200 600 1500 211 (8.3) Horizontal process connection f 230 2 inch 150 n xd 2 dM 24 lb/ sq.in. øD L d5 PN 100 32 Nom. Nom. b diam. press. Tube length L see Ordering Data øk d4 Connection to ASME B16.5 ø d5 ø d4 PN 40 d2 226 (8.9) mm D d2 d4 d5 dM f k mm mm mm mm mm mm mm (inch) (inch) (inch) (inch) (inch) (inch) (inch) (inch) 20 20 150 300 4 inch 150 300 1.6 120.5 4 (2.32) (0.06) (4.74) 22.5 20 59 165 92 48.3 1.6 127 (0.89) (6.5) (0.79) (3.62) (1.9) (2.32) (0.06) (5) 32 20 59 165 92 48.3 6.4 127 (1.26) (6.5) (0.79) (3.62) (1.9) (2.32) (0.25) (5) 45 26 59 215 24 190 29 210 (1.14) (8.27) 600 59 (0.79) (3.62) (1.9) (0.95) (7.48) Diaphragm seals of flange design, direct connection to a SITRANS P pressure transmitter (process connection vertical (top) and horizontal (bottom)), dimensions in mm (inch) 48.3 (0.79) (5.91) (1.77) (8.46) 3 inch 150 92 38.5 210 92 48.3 (1.02) (3.62) (1.9) 20 127 (0.79) (5) 22 127 (0.87) (5) 127 165 76 89 (3) (3.50) (0.06) (6) 1.6 76 89 (3) (3.50) (0.06) (6.63) 1.6 76 89 (3.50) (0.25) (6.63) 24 6.4 20 94 89 1.6 168.5 8 190.5 8 (0.95) (9.06) (0.79) (6.22) (3.69) (3.50) (0.06) (7.5) 32 22 158 94 8 168.5 8 (3) 255 8 152.5 4 (0.87) (5) 158 8 (2.32) (0.25) (6.5) (1.52) (8.27) 230 22 6.4 n 89 1.6 200 8 (1.26) (10.04) (0.79) (6.22) (3.69) (3.50) (0.06) (7.87) 400 41.5 255 26 158 94 89 6.4 200 (1.62) (10.04) (1.02) (6.22) (3.69) (3.50) (0.25) (7.87) d: Inside diameter of gasket according to EN 1092-1/ ASME B16.5 dM: Effective diaphragm diameter 2/166 Siemens FI 01 · 2009 8 © Siemens AG 2008 SITRANS P measuring instruments for pressure Diaphragm seals of flange design For differential pressure, fixed connection and with capillary ■ Overview 2 Diaphragm seals of flange design for pressure transmitters for differential pressure, fixed connection and with flexible capillary ■ Technical specifications Diaphragm seals of flange design for pressure transmitters for differential pressure, fixed connection and with flexible capillary Nominal diameter Nominal pressure • DN 80 PN 40 • DN 100 PN 16, PN 40 • 3 inch Class 150, class 300 • 4 inch Class 150, class 300 Tube length Without tube 50 mm (1.97 inch) 100 mm (3.94 inch) 150 mm (5.91 inch) 200 mm (7.87 inch) Capillary • Length Max. 10 m (32.8 ft), longer lengths on request Sealing face • For stainless steel, mat. No. 1.4404/316L To EN 1092-1, form B1 or ASME B16.5 RF 125 ... 250 AA • Internal diameter 2 mm (0.079 inch) • Minimum bending radius 150 mm (5.9 inch) • For the other materials To EN 1092-1, form B2 or ASME B16.5 RFSF Filling liquid Silicone oil M5 Silicone oil M50 Materials High-temperature oil • Main body Stainless steel 316L Halocarbon oil (for measuring O2) • Wetted parts Stainless steel 316L Food oil (FDA listed) • Without foil Glycerine/water (not suitable for use in low-pressure range) • PTFE (for vacuum on request) • ECTFE (for vacuum on request) • PFA (for vacuum on request) Monel 400, mat. No. 2.4360 Max. recommended process temperature 170 °C (338 °F) Permissible ambient temperature Dependent on the pressure transmitter and the filling liquid of the remote seal More information can be found in the technical data of the pressure transmitters and in the section "Technical data of filling liquid" in the Technical description to the remote seals Weight Approx. 4 kg (8.82 lb) Hastelloy C276, mat. No. 2.4819 Hastelloy C4, mat. No. 2.4610 Tantalum • Capillary Stainless steel, mat. No. 1.4571/316Ti • Sheath Spiral hose made of stainless steel, mat. No. 1.4301/316 Certificate and approvals Sealing material in the process flanges • For pressure transmitters, absolute pressure transmitters and lowpressure applications Copper • For other applications Viton Maximum pressure See above and the technical data of the pressure transmitter Classification according to pressure equipment directive (DRGL 97/23/EC) For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of article 3, paragraph 3 (sound engineering practice) Siemens FI 01 · 2009 2/167 © Siemens AG 2008 SITRANS P measuring instruments for pressure Diaphragm seals of flange design For differential pressure, fixed connection and with capillary Order No. Ord. code Selection and Ordering data D) 7 M F 4 9 1 3 - Diaphragm seal 2 Mounting flange (with tube as option) for direct mounting to high-pressure side and flanged remote seal without tube, fitted by means of capillary to low-pressure side of SITRANS P for differential pressure, DS III series (7MF4437) Flange, connection to EN 1092-1 Nom. diam. Nom. press. • DN 80 PN 40 • DN 100 PN 16 PN 40 1 7777 - 7B 777 Class 150 Class 300 Class 150 Class 300 • 4 inch Other version Add Order code and plain text: Flange: ..., Nominal diameter: ...; Nominal pressure: ... Wetted parts materials Smooth sealing face to EN 1092-1, form B1 or B2, or to ASME B16.5 RF 125 ... 250 AA or RFSF • Stainless steel 316L - without foil - with PTFE coating - with ECTFE coating1) - with PFA coating • Monel 400, mat. No. 2.4360 • Hastelloy C276, mat. No. 2.4819 • Hastelloy C4, mat. No. 2.4610 • Tantalum Other version Add Order code and plain text: Wetted parts materials: ... D G H Filling liquid • Silicone oil M5 • Silicone oil M50 • High-temperature oil • Halocarbon oil (for measuring O2) • Glycerin/water2) • Food oil (FDA listed) Other version Add Order code and plain text: Filling liquid: ... 2/168 Siemens FI 01 · 2009 1 7777 - 7B 777 (3.28 ft) (5.25 ft) (8.20 ft) (13.1 ft) • 6.0 m (19.7 ft) • 8.0 m (26.25 ft) • 10.0 m (32.8 ft) Other version Add Order code and plain text: Length of capillary: ... Q R T U Z J1Y 2 3 4 5 6 7 8 9 N1Y 1) For vacuum on request. Not suitable for use in low-pressure range. Max. capillary length, see section "Technical description". D) Subject to export regulations AL: N, ECCN: EAR99H. 2) 3) Selection and Ordering data Order code Further designs Please add "-Z" to Order No. and specify Order code. A E0 F D G J U K Z K1Y Tube length (for mounting flange on high-pressure side) • Without tube • 50 mm (1.97 inch) • 100 mm (3.94 inch) • 150 mm (5.90 inch) • 200 mm (7.87 inch) Other version: Add Order code and plain text: Tube length: ... Mounting flange (with tube as option) for direct mounting to high-pressure side and flanged remote seal without tube, fitted by means of capillary to low-pressure side of SITRANS P for differential pressure, DS III series (7MF4437) Length of capillary3) • 1.0 m • 1.6 m • 2.5 m • 4.0 m Order No. Ord. code D) 7 M F 4 9 1 3 - Diaphragm seal Flange, connection to ASME B16.5 Nom. diam. Nom. press. • 3 inch Selection and Ordering data 0 1 2 3 4 9 L1Y 1 2 3 4 6 7 9 M1 Y Spark arrestor With spark arrestor for mounting on zone 0 (including documentation) A02 Quality inspection certificate (Factory calibration) to IEC 60770-2 C11 Acceptance test certificate to EN 10204, section 3.1 C12 Vacuum-proof design for use in low-pressure range V03 Calculation of span of associated pressure transmitter Enclose filled-in questionnaire with order Y05 © Siemens AG 2008 SITRANS P measuring instruments for pressure Diaphragm seals of flange design For differential pressure, fixed connection and with capillary ■ Dimensional drawings Connection to EN 1092-1 D dM Nom. diam. Nom. b press. mm mm mm mm mm mm mm DN 80 PN 40 24 200 18 138 76 89 2 160 8 DN 100 PN 16 20 200 18 158 94 89 2 180 8 PN 40 24 235 22 162 94 89 2 190 8 b mm f ø d4 ø k R _> 15 0( 5.9 ) n xd 2 D lb/ sq.in. + 3 inch 150 d5 dM f k n mm D d2 d4 d5 dM f k mm mm mm mm mm mm mm (inch) (inch) (inch) (inch) (inch) (inch) (inch) (inch) 24 20 190 (0.96) (7.48) 300 n xd 2 d4 2 Connection to ASME B16.5 Nom. Nom. b diam. press. L d2 b 4 inch 150 f 300 29 210 127 (0.79) (5) 127 89 (3.50) (0.06) (6) 1,6 76 89 (0.87) (5) (3) (3.50) (0.06) (6.63) 24 20 94 89 158 1,6 152,5 (1.14) (8.27) 230 22 76 (3) 1,6 168,5 190,5 (0.95) (9.06) (0.79) (6.22) (3.69) (3.50) (0.06) (7) 32 22 255 158 94 89 1,6 200 n 4 8 4 8 ø d4 ø d5 øD øk (1.26) (10.04) (0.87) (6.22) (3.69) (3.50) (0.06) (7.87) 100 (3.94) Tube length L see Ordering data d: Inside diameter of gasket according to EN 1092-1 / ASME B16.5 dM: Effective diaphragm diameter Diaphragm seals of flange design with flexible capillary, fixed connection, for connection to a SITRANS P pressure transmitter for differential pressure, dimensions in mm (inch) Siemens FI 01 · 2009 2/169 © Siemens AG 2008 SITRANS P measuring instruments for pressure Quick-release diaphragm seals For gage, absolute and differential pressure ■ Overview - DN 65 PN 25 - DN 80 PN 25 • Clamp connection 2 - 1½ inch PN 40 - 2 inch PN 40 - 2½ inch PN 25 - 3 inch PN 25 For differential pressure and flow • To DIN 11851 with slotted union nut - DN 50 PN 25 - DN 65 PN 25 - DN 80 PN 25 • To DIN 11851 with threaded socket Quick-release diaphragm seals, to DIN 11851 with slotted union nut - DN 50 PN 25 - DN 65 PN 25 - DN 80 PN 25 • Clamp connection - 2 inch PN 40 - 2½ inch PN 25 - 3 inch PN 25 Sealing face • For stainless steel, mat. No. 1.4404/316L To EN 1092-1, form B1 or ASME B 16.5RF 125 ... 250 AA • For the other materials To EN 1092-1, form B2 or ASME B16.5 RFSF Materials Quick-release diaphragm seals, with clamp connection Quick-release diaphragm seals are available for the following SITRANS P pressure transmitter series: • For pressure: MK II, DS III, DS III PA, DS III FF • For differential pressure and flow: DS III, DS III PA, DS III FF The quick-release remote seals are common designs in the food industry. Their design means that the measured medium cannot accumulate in dead volumes. The quick-release clamp present on the remote seal means that quick dismounting is possible for cleaning. ■ Technical specifications Quick-release diaphragm seal Connection, nominal diameter • Main body Stainless steel 316L • Wetted parts Stainless steel 316L • Capillary Stainless steel, mat. No. 1.4571/316Ti • Sheath Spiral hose made of stainless steel, mat. No. 1.4301/316 Maximum pressure See above and the technical data of the pressure transmitter Tube length Without tube Capillary • Length Max. 10 m (32.8 ft), longer lengths on request • Internal diameter 2 mm (0.079 inch) • Minimum bending radius 150 mm (5.9 inch) Filling liquid Food oil (FDA listed) Nominal pressure Glycerin/water (not suitable for use in low-pressure range) For pressure • To DIN 11851 with slotted union nut - DN 25 PN 40 - DN 32 PN 40 - DN 40 PN 40 - DN 50 PN 25 - DN 65 PN 25 - DN 80 PN 25 • To DIN 11851 with threaded socket PN 40 - DN 32 PN 40 - DN 40 PN 40 - DN 50 PN 25 Siemens FI 01 · 2009 Dependent on the pressure transmitter and the filling liquid of the remote seal More information can be found in the technical data of the pressure transmitters and in the section "Technical data of filling liquid" in the Technical description to the remote seals Weight Approx. 4 kg (8.82 lb) Certificates and approvals - DN 25 2/170 Permissible ambient temperature Classification according to pressure equipment directive (DRGL 97/23/EC) For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of article 3, paragraph 3 (sound engineering practice) © Siemens AG 2008 SITRANS P measuring instruments for pressure Quick-release diaphragm seals For gage, absolute and differential pressure Order No. Ord. code Selection and Ordering data Quick-release diaphragm seal D) 7 M F 4 9 4 0 - for SITRANS P pressure transmitters for pressure 7MF403 7 and 7MF4237 together with Order code "V01" (vacuum-proof design) and 7MF80271); must be ordered separately Filling liquid: Food oil (FDA listed) Material: Stainless steel, mat. No. 1.4435 Nom. diam. Nom. press. • Connection to DIN 11851 with slotted union nut - DN 25 PN 40 - DN 32 PN 40 - DN 40 PN 40 - DN 50 PN 25 - DN 65 PN 25 - DN 80 PN 25 • Connection to DIN 11851 with screw necks - DN 25 PN 40 - DN 32 PN 40 - DN 40 PN 40 - DN 50 PN 25 - DN 65 PN 25 - DN 80 PN 25 • Clamp connection - 1½ inch PN 40 - 2 inch PN 40 - 2½ inch PN 40 - 3 inch PN 40 Other version Add Order codes and plain text: Nominal diameter: ... Nominal pressure: ... D) 7 M F 4 9 4 3 - Quick-release diaphragm seal 77 A 0 7 - 7B 777 for SITRANS P pressure transmitters for pressure for differential pressure and flow, type 7MF4437; order separately Filling liquid: Food oil (FDA listed) Material: Stainless steel, mat. No. 1.4435 Delivery unit: 2 off Nom. diam. Nom. press. • Connection to DIN 11851 with slotted union nut - DN 50 PN 25 - DN 65 PN 25 - DN 80 PN 25 • Connection to DIN 11851 with threaded socket - DN 50 PN 25 - DN 65 PN 25 - DN 80 PN 25 • Clamp connection - 2 inch PN 40 - 2½ inch PN 40 - 3 inch PN 40 1B 1C 1D 1E 1F 1G 2B 2C 2D 2E 2F 2G Other version Add Order codes and plain text: Nominal diameter: ... Nominal pressure: ... 4L 4M 4N 4P 9 H1Y J1Y Z 77 A 0 7 - 7B 777 2 1E 1F 1G 2E 2F 2G 4M 4N 4P 9 H1Y J1Y Z Filling liquid • Glycerin/water1) • Food oil (FDA listed) Other version Add Order code and plain text: Filling liquid: ... 6 7 9 M1 Y Connection to transmitter Filling liquid • Glycerin/water2) • Food oil (FDA listed) Other version Add Order code and plain text: Filling liquid: ... 6 7 9 Connection to pressure transmitter • direct M1 Y 0 through capillary, length:3) • 1.0 m (3.28 ft) • 1.6 m (5.25 ft) • 2.5 m (8.20 ft) • 4.0 m (13.1 ft) • 6.0 m (19.7 ft) • 8.0 m (26.25 ft) • 10.0 m (32.8 ft) Other version Add Order code and plain text: Length of capillary: ... Further designs Order No. Ord. code Selection and Ordering data 2 3 4 5 6 7 8 9 Order code through capillary, Length:2) • 1.0 m (3.28 ft) • 1.6 m (5.25 ft) • 2.5 m (8.20 ft) • 4.0 m (13.1 ft) • 6.0 m (19.7 ft) • 8.0 m (26.25 ft) • 10.0 m (32.8 ft) Other version Add Order code and plain text: Length of capillary: ... N1Y Order code Further designs Please add "-Z" to Order No. and specify Order code. N1Y Quality inspection certificate (Factory calibration) to IEC 60770-2 C11 Acceptance test certificate C12 to EN 10204, section 3.1 Vacuum-proof design Please add "-Z" to Order No. and specify Order code. 2 3 4 5 6 7 8 9 V03 for use in low-pressure range Quality inspection certificate (Factory calibration) to IEC 60770-2 C11 Acceptance test certificate C12 1) Not suitable for use in low-pressure range. Max. capillary length, see section "Technical description" D) Subject to export regulations AL: N, ECCN: EAR99H. 2) to EN 10204, section 3.1 Vacuum-proof design V01 for use in low-pressure range 1) With 7MF8027 and the measuring cells Q, S, T and U also order the vacuum-tight version. 2) Not suitable for use in low-pressure range. 3) Max. capillary length, see section "Technical description" D) Subject to export regulations AL: N, ECCN: EAR99H. Siemens FI 01 · 2009 2/171 © Siemens AG 2008 SITRANS P measuring instruments for pressure Quick-release diaphragm seals For gage, absolute and differential pressure ■ Dimensional drawings H H H 146 (5.75) 2 dM dM DN D D G1 dM dM DN dM D D dM G1 DN DN Mounted directly on SITRANS P transmitter for pressure R ³ 15 0( 5.9 ) G1 DN DN G1 Mounted on SITRANS P transmitter for pressure or differential pressure and flow Clamp connection (left) DN (1½ inch) (2 inch) (2½ inch) (3 inch) Ø dM 32 (1.26) 40 (1.57) 52 (2.05) 72 (2.83) ØD 50,5 64 77,5 91 (2) (2.52) (3.05) (3.58) H 35 35 35 35 (1.38) (1.38) (1.38) (1.38) Connection to DIN 11851 with slotted union nut (center) Connection to DIN 11851 with threaded socket (right) DN 25 32 40 50 65 80 25 DN 25 32 40 50 65 80 dM Effective diaphragm diameter Quick-release diaphragm seal, dimensions in mm (inch) 2/172 Siemens FI 01 · 2009 Ø dM 25 32 40 52 65 72 25 ØD 63 70 78 112 112 127 63 H 36 36 36 36 36 36 36 G1 Rd 52x1/6 Rd 52x1/6 Rd 65x1/6 Rd 78x1/6 Rd 95x1/6 Rd 110x1/6 Rd 52x1/6 Ø dM 25 32 40 52 65 72 H 36 36 36 36 36 36 G1 Rd 52x1/6 Rd 52x1/6 Rd 65x1/6 Rd 78x1/6 Rd 95x1/6 Rd 110x1/6 © Siemens AG 2008 SITRANS P measuring instruments for pressure Miniature diaphragm seal For gage and absolute pressure ■ Overview ■ Technical specifications Miniature diaphragm seals Span with • G1B • G1½B • G2B > 6 bar (> 87 psi) > 2 bar (> 29 psi) > 600 mbar (> 8.7 psi) Filling liquid Silicone oil M5 or food oil (FDA listed) Material • Main body • Diaphragm Stainl. steel mat No. 1.4404/ 316L Stainl. steel mat No. 1.4404 / 316L Maximum pressure 100% of nominal pressure of pressure transmitter, up to maximum of PN 400 (5802 psi) (depending on the seal used) Miniature diaphragm seals Temperature of use Same as pressure transmitter The miniature diaphragm seals are available for the following SITRANS P pressure transmitter series for pressure: • P300, DS III, DS III PA, DS III FF Suitable for high pressures, contaminated, fibrous and viscous media in the chemical, paper, food and drink industries. Temperature range of medium Same as pressure transmitter Max. recommended process temperature 150 °C (302 °F) ■ Design Weight • G1B • G1½B • G2B Certificate and approvals Classification according to pressure equipment directive (DRGL 97/23/EC) • Flush-mounted diaphragm • No dead spaces • Fixed threaded stems ■ Dimensional drawings Approx. 0.3 kg (approx. 0.66 lb) Approx. 0.5 kg (approx. 1.10 lb) Approx. 0.8 kg (approx. 1.76 lb) For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of article 3, paragraph 3 (sound engineering practice) Order No. Ord. code Selection and Ordering data D) 7 M F 4 9 6 0 - Miniature diaphragm seals directly fitted to SITRANS P pressure transmitters for pressure; type, 7MF403 7 and 7MF4237 together with Order code "V01" (vacuum-proof design) and 7MF80271); must be ordered separately Material: Stainless steel, mat. No. 1.4401 Pressure rating, see "Pressure transmitters" 146 (5.75) Process connection • G1B • G1½B • G2B • 1“ - NPT • 1½“ - NPT • 2“ - NPT Other version, add Order code and plain text: Process connection: ... 1 77 0 7 C D E K L M Z Wetted parts materials • Stainless steel 316L Other version, add Order code and plain text: Wetted parts materials: ... SW J1Y A Z H Filling liquid • Silicone oil M5 • Food oil (FDA listed) Other version, add Order code and plain text: Filling liquid: ... L 777 K1Y 1 7 9 M1 Y 1) dM With 7MF8027 and the measuring cells Q, S, T and U also order the vacuum-tight version. D) Subject to export regulations AL: N, ECCN: EAR99H. d Selection and Ordering data G G Ø dM SW Ød L H mm (inch) mm (inch) mm (inch) mm (inch) mm (inch) 25 (0.98) 41 (1.61) 39 (1.53) 28 (1.1) 56 (2.21) G1½B 40 (1.57) 55 (2.17) 60 (2.36) 30 (1.18) 50 (1.97) G2B (1.97) 60 (2.36) 70 (2.76) 30 (1.18) 63 (2.48) G1B 50 dM: Effective diaphragm diameter Order code Further designs Please add "-Z" to Order No. and specify Order code. Quality inspection certificate (Factory calibration) to IEC 60770-2 C11 Acceptance test certificate to EN 10204, section 3.1 C12 Vacuum-proof design for use in low-pressure range V01 Miniature diaphragm seal, dimensions in mm (inch) Siemens FI 01 · 2009 2/173 2 © Siemens AG 2008 SITRANS P measuring instruments for pressure Flushing rings For diaphragm seals ■ Overview ■ Technical specifications Flushing ring for remote seals of sandwich and flange design 2 Nominal diameter Nominal pressure • DN 50 PN 16 ... PN 100 • DN 80 PN 16 ... PN 100 • DN 100 PN 16 ... PN 100 • DN 125 PN 16 ... PN 100 • 2 inch Class 150 ... class 600 • 3 inch Class 150 ... class 600 • 4 inch Class 150 ... class 600 • 5 inch Class 150 ... class 600 Flushing ring Sealing face Flushing rings are required for flange-mounted and sandwichtype remote seals (Order No. 7MF4900 ... 7MF4923) if the danger exists that the process conditions and the geometry of the connection could cause the medium to form deposits or blockages. • To EN 1092-1 Form B2 Form D/Form D Form C/Form C The flushing ring is clamped between the process flange and the remote seal. Deposits can be flushed away from the diaphragm through the holes in the side, or the pressure volume can be vented. Different nominal diameters and forms permit adaptation to the respective process flange. Form C/Form C Form E Form F • To ASME B16.5 RJT ring groove Flushing holes (2 off), female thread: For flanges to EN and ASME: DN 50, 80, 100, 125; PN 16 ... 100 or DN 2 inch, 3 inch, 4 inch, 5 inch; Class 150 ... 600 ■ Design Spülring Flushing ring Dichtung Measuring point flange Installation example 2/174 Siemens FI 01 · 2009 • G½ • ½-14 NPT Material: CrNi-Stahl, mat. No. 1.4404/316L Sealing faces and flushing holes: See Selection and Ordering data Gasket • G¼ • ¼-18 NPT Standard design Flushing outlet RF 125 ... 250 AA RFSF Process connection Remote seal flange Form B1 Flushing inlet Material Stainless steel 1.4404/316L © Siemens AG 2008 SITRANS P measuring instruments for pressure Flushing rings For diaphragm seals Selection and Ordering data Order No. Ord. code D) 7 M F 4 9 2 5 - 1 7777 Nom. diam. • DN 50 • DN 80 • DN 100 • DN 125 Nom. press. PN 16 ... PN 100 PN 16 ... PN 100 PN 16 ... PN 100 PN 16 ... PN 100 A B C D • 2 inch • 3 inch • 4 inch • 5 inch Class 150 ... 600 Class 150 ... 600 Class 150 ... 600 Class 150 ... 600 G H J K Other version Add Order code and plain text: Nominal diameter: ...; Nominal pressure: ... - Form C/Form C - Form D/Form C - Form D/Form D - Form E - Form F • ASME B16.5 - RF 125 ... 250 AA - RFSF - RJT ring groove Other version Add Order code and plain text: Sealing face: ... Flushing holes (2 off) • Female thread G¼ • Female thread G½ • Female thread ¼-18 NPT • Female thread ½-14 NPT Material • Stainless steel 316L Other version Add Order code and plain text: Material: ... Selection and Ordering data 2 di d4 Z Sealing face • EN 1092-1 - Form B1 - Form B2 777 Thread for remote seals 7MF4900 to 7MF4923 ■ Dimensional drawings h Flushing ring J1Y Connection to EN 1092-1 DN PN d4 di h (mm) (bar) (mm) (mm) (mm) Weight (kg) 50 16 ... 100 102 62 30 1.10 A C 80 16 ... 100 138 92 30 1.90 100 16 ... 100 162 92 30 3.15 D E F 125 16 ... 100 188 126 30 3.50 Connection to ASME B 16.5 DN G H inch M Q R Z K1Y Class di d4 mm h Weight (inch) mm (inch) mm (inch) kg (lb) (1.32) 2 150 ... 600 92 (3.62) 62 (2.44) 30 (1.18) 0.60 3 150 ... 600 127 (5) 92 (3.62) 30 (1.18) 1.05 (2.31) 4 150 ... 600 157 (6.18) 92 (3.62) 30 (1.18) 2.85 (6.28) 5 150 ... 600 185.5 (7.3) 126 (4.96) 30 (1.18) 3.30 (7.28) Flushing ring, dimension drawing 1 2 3 4 0 9 M1 Y Order code Further designs Please add "-Z" to Order No. and specify Order code. Acceptance test certificate to EN 10204, section 3.1 C12 D) Subject to export regulations AL: N, ECCN: EAR99H. Siemens FI 01 · 2009 2/175 © Siemens AG 2008 SITRANS P measuring instruments for pressure Clamp-on seals of flange design For gage pressure, differential pressure and flow ■ Overview ■ Technical specifications Clamp-on seals for flange-mounting 2 Nominal diameter Nominal pressure • DN 25 PN 6 ... PN 100 • DN 40 PN 6 ... PN 100 • DN 50 PN 6 ... PN 100 • DN 80 PN 6 ... PN 100 • DN 100 PN 6 ... PN 100 • 1 inch Class 150 ... class 2500 • 1½ inch Class 150 ... class 2500 • 2 inch Class 150 ... class 2500 • 3 inch Class 150 ... class 2500 • 4 inch Class 150 ... class 2500 Process connection Flange to EN 1092-1 or ASME B 16.5 Clamp-on seals for flange-mounting Sealing face The clamp-on seal is completely integrated in the process line. It is particularly suitable for flowing and highly viscous media. To EN 1092-1, form B1 or to ASME B16.5 RF 125 ... 250 A or RFSF Materials The clamp-on remote seal consists of a cylindrical jacket into which a thin-walled pipe is welded. It is clamped directly between two flanges in the pipeline. ■ Design • Main body Stainless steel 1.4404/316L • Diaphragm Stainless steel 1.4404/316L • Wetted parts Stainless steel 1.4404/316L • Without foil • Clamp-on seals for flange-mounting (flange design) to EN/ASME for SITRANS P pressure transmitters - For pressure: P300, DS III, DS III PA and DS III FF series - For differential pressure and flow: DS III, DS III PA and DS III FF • Sealing face to EN 1092-1 or ASME B16.5 • Connection to the transmitter directly or by means of a flexible capillary (max. 10 m long) • See Technical data for details of materials used for the wetted parts • Material used for the capillary, the guard sleeve, the seal’s main body and the measuring cell: Stainless steel, mat.-No. 1.4571 • Filling liquid: Silicone oil, high-temperature oil, halocarbon oil, food oil (FDA listed) or glycerin/water (not suitable for uses in low-pressure range) • ECTFE coating • PFA coating (for vacuum on request) Monel 400, mat. No. 2.4360 Hastelloy C276, mat. No. 2.4819 Hastelloy C4, mat. No. 2.4610 Tantalum • Capillary Stainless steel, mat. No. 1.4571/316Ti • Sheath Spiral hose made of stainless steel, mat. No. 1.4301/316 Capillary • Length Max. 10 m (32.8 ft) • Internal diameter 2 mm (0.079 inch) • Minimum bending radius 150 mm (5.9 inch) Filling liquid ■ Function Silicone oil M5 Silicone oil M50 The measured pressure is transferred from the diaphragm to the filling liquid and passes either directly or through the capillary to the measuring chamber of the pressure transmitter. The interior of the diaphragm seal and of the capillary, as well as the measuring chamber of the pressure transmitter, are filled gas-free by the filling liquid. High-temperature oil Halocarbon oil Food oil (FDA listed) Glycerin/water (not suitable for uses in low-pressure range) Note: Permissible ambient temperature When operating in the low-pressure range, also during commissioning, it is recommended to use a vacuum-proof remote seal (see Selection and Ordering data). See pressure transmitters, see filling liquid Weight Approx. 4 kg (8.82 lb) Certificates and approvals Classification according to pressure equipment directive (DRGL 97/23/EC) 2/176 Siemens FI 01 · 2009 For gases of fluid group 1 and liquids of fluid group 1; complies with the requirements of article 3, paragraph 1 (appendix 1); assigned to category III, conformity evaluation module H by the TÜV Nord © Siemens AG 2008 SITRANS P measuring instruments for pressure Clamp-on seals of flange design For gage pressure, differential pressure and flow Selection and Ordering data Order No. Ord. code Order code Selection and Ordering data Clamp-on seal for flange-mounting for SITRANS P pressure transmitters Further designs Please add "-Z" to Order No. and specify Order code. D) 7 M F 4 9 8 0 for pressure 7MF403 7 and 7MF4237 together with Order code "V01" (vacuum-proof design) and 7MF80271); must be ordered separately, scope of delivery: 1 off Spark arrestor With spark arrestor for mounting on zone 0 (including documentation) • Pressure and absolute pressure A01 D) 7 M F 4 9 8 3 for differential pressure and flow 7MF4433 or 7MF4434; order separately, scope of delivery: 1 pair (set); Material: Completely of stainless steel, mat. No. 1.4404/316L; Process connection to EN 1092-1 or ASME B16.5; sealing face to EN 1092-1, form B1, or to ASME B16.5 RF 125 ... 250 AA • for differential pressure transmitters A02 Quality inspection certificate (Factory calibration) to IEC 60770-2 C11 Acceptance test certificate To EN 10204, section 3.1 C12 Vacuum-proof design For use in low-pressure range V01 Calculation of span of associated pressure transmitter Enclose filled-in questionnaire with order Note: Suffix "Y01" required with pressure transmitter! Y05 1 77 0 7 - 7B 777 Nominal diameter and nominal pressure • DN 25 PN 6 ... 100 • DN 40 PN 6 ... 100 • DN 50 PN 6 ... 100 • DN 80 PN 6 ... 100 • DN 100 PN 6 ... 100 B D E G H • 1 inch • 1½ inch • 2 inch • 3 inch • 4 inch L M N P Q Class 150 ... 2500 Class 150 ... 2500 Class 150 ... 2500 Class 150 ... 2500 Class 150 ... 2500 Other version Add Order code and plain text: Nominal diameter: ...; Nominal pressure: ... Wetted parts materials • Stainless steel 316L - Without foil - With PFA coating - With ECTFE coating2) • Monel 400, mat. No. 2.4360 • Hastelloy C276, mat. No. 2.4819 • Hastelloy C4, mat. No. 2.4610 • Tantalum Other version Add Order code and plain text: Wetted parts materials: ... Filling liquid • Silicone oil M5 • Silicone oil M50 • High-temperature oil • Halocarbon oil (for measuring O2) • Glycerin/water3) • Food oil (FDA listed) Other version Add Order code and plain text: Filling liquid: ... Connection to transmitter • direct (only for 7MF4980) through capillary, length:4) • 1.0 m (3.28 ft) • 1.6 m (5.25 ft) • 2.5 m (8.20 ft) • 4.0 m (13.1 ft) • 6.0 m (19.7 ft) • 8.0 m (26.25 ft) • 10.0 m (32.8 ft) Other version Add Order code and plain text: Length of capillary: ... 1) 2) 3) 4) 2 D) Subject to export regulations AL: N, ECCN: EAR99H. Z J1Y A D F G J U K Z K1Y 1 2 3 4 6 7 9 M1 Y 0 2 3 4 5 6 7 8 9 N1Y With 7MF8027 and the measuring cells Q, S, T and U also order the vacuum-tight version. For vacuum on request. Not suitable for use in low-pressure range. Max. capillary length, see section "Technical description" Siemens FI 01 · 2009 2/177 © Siemens AG 2008 SITRANS P measuring instruments for pressure Clamp-on seals of flange design For gage pressure, differential pressure and flow ■ Dimensional drawings Connection to EN 1092-1 2 146 (5.75) DN PN D Mb L mm bar mm mm mm H mm 25 6 ... 100 63 28,5 60 78.5 40 6 ... 100 85 43 60 89.5 50 6 ... 100 95 54.5 60 92.5 80 6 ... 100 130 82.5 60 112 100 6 ... 100 150 107 60 122 D Mb L H mm mm mm mm (inch) (inch) (inch) (inch) 63 28.5 60 78.5 (2.48) (1.12) (2.36) (3.1) 85 43 60 86 (3.35) (1.69) (2.36) (3.4) 94.5 Connection to ASME B16.5 DN Class (inch) H 1 150 ... 2500 1½ 150 ... 2500 2 150 ... 2500 ø Mb D L Bending radius ³ 150 mm (5.9) Clamp-on seal for flange-mounting, connected to SITRANS P pressure transmitter, dimensions in mm (inch) 2/178 Siemens FI 01 · 2009 3 150 ... 2500 4 150 ... 2500 95 54.5 60 (3.74) (2.15) (2.36) (3.72) 130 82.5 60 112 (5.12) (3.25) (2.36) (4.4) 150 107 60 122 (5.9) (4.21) (2.36) (4.8) © Siemens AG 2008 SITRANS P measuring instruments for pressure Quick-release clamp-on seals For pressure and absolute pressure ■ Overview ■ Function The measured pressure is transferred from the diaphragm, mounted on the inner circumference of the clamp-on seal, to the filling liquid and then passes through the capillary to the measuring chamber of the pressure transmitter. The interior of the clamp-on seal and of the capillary, as well as the measuring chamber of the pressure transmitter, are filled gas-free by the filling liquid. Note: When operating in the low-pressure range, also during commissioning, it is recommended to use a vacuum-proof pressure transmitter (see Selection and Ordering data). ■ Technical specifications Clamp-on seals of quick-release design for pressure Quick-release clamp-on seals, to DIN 11851 with threaded socket Connection Nominal diameter Nominal pressure • To DIN 11851 with threaded socket DN 25 PN 40 DN 40 PN 40 DN 50 PN 25 DN 65 PN 25 DN 80 PN 25 DN 100 PN 25 1½ inch PN 40 • Clamp connection 2 inch PN 40 2½ inch PN 40 3 inch PN 40 Material • Main body Stainless steel 1.4404/316L • Diaphragm Stainless steel 1.4404/316L Capillary • Length Max. 10 m (32.8 ft) Quick-release clamp-on seals, with clamp connection • Internal diameter 2 mm (0.079 inch) Quick-release clamp-on seals for pressure are available for the following SITRANS P pressure transmitter series: • P300 • DS III • DS III PA • DS III FF • Minimum bending radius 150 mm (5.9 inch) Filling liquid • Food oil (FDA listed) • Glycerin/water (not suitable for use in low-pressure range) Permissible ambient temperature Dependent on the pressure transmitter and the filling liquid of the remote seal More information can be found in the technical data of the pressure transmitters and in the section "Technical data of filling liquid" in the Technical description to the remote seals Weight Approx. 4 kg (approx. 8.82 lb) ■ Application The quick-release clamp-on seal is a special design for flowing media and high-viscosity media. Since it is completely integrated in the process pipe, no turbulences, dead volumes or other obstructions to the flow occur. The measured medium flows unhindered through the clamp-on seal and results in selfcleaning of the measuring chamber. Furthermore, the clamp-on seal can be cleaned by a pig. ■ Design The quick-release clamp is available in two versions: • DIN 11851 with threaded socket • Clamp connection Certificate and approvals Classification according to pressure equipment directive (DRGL 97/23/EC) For gases of fluid group 1 and liquids of fluid group 1; complies with the requirements of article 3, paragraph 1 (appendix 1); assigned to category III, conformity evaluation module H by the TÜV Nord The clamp-on seal is connected to the pressure transmitter either directly or by way of a capillary. Siemens FI 01 · 2009 2/179 2 © Siemens AG 2008 SITRANS P measuring instruments for pressure Quick-release clamp-on seals For pressure and absolute pressure Selection and Ordering data Quick-release clamp-on seal 2 for SITRANS P pressure transmitters for pressure 7MF403 7 and 7MF4237 together with Order code "V01" (vacuum-proof design) and 7MF80271); must be ordered separately Filling liquid: Food oil (FDA listed) Material: Stainless steel 316L Nom. diam. Nom. press. • Connection to DIN 11851 with screw necks - DN 25 PN 40 - DN 40 PN 40 - DN 50 PN 25 - DN 65 PN 25 - DN 80 PN 25 - DN 100 PN 25 • Clamp connection - 1½ inch PN 40 - 2 inch PN 40 - 2½ inch PN 40 - 3 inch PN 40 Other version Add Order codes and plain text: Nominal diameter: ... Nominal pressure: ... Order No. Ord. code D) 7 M F 4 9 5 0 77 A 0 7 - 7B 777 2B 2D 2E 2F 2G 2H 4L 4M 4N 4P 9 H1Y J1Y Z Filling liquid • Glycerin/water2) • Food oil (FDA listed) Other version Add Order code and plain text: Filling liquid: ... Connection to transmitter • Direct 6 7 9 M1 Y 0 3) Through capillary, length: • 1.0 m (3.28 ft) • 1.6 m (5.25 ft) • 2.5 m (8.20 ft) • 4.0 m (13.1 ft) • 6.0 m (19.7 ft) • 8.0 m (26.25 ft) • 10.0 m (32.8 ft) Other version Add Order code and plain text: Length of capillary: ... 2 3 4 5 6 7 8 9 N1Y 1) With 7MF8027 and the measuring cells Q, S, T and U also order the vacuum-tight version. Not suitable for use in low-pressure range. 3) Max. capillary length, see section "Technical description" D) Subject to export regulations AL: N, ECCN: EAR99H. 2) Selection and Ordering data Order code Further designs Please add "-Z" to Order No. and specify Order code. Quality inspection certificate (Factory calibration) to IEC 60770-2 C11 Acceptance test certificate to EN 10204, section 3.1 C12 Vacuum-proof design for use in low-pressure range V01 2/180 Siemens FI 01 · 2009 © Siemens AG 2008 SITRANS P measuring instruments for pressure Quick-release clamp-on seals For pressure and absolute pressure ■ Dimensional drawings H D D1 d D2 1 G D1 D2 DN H 146 (5.9) 2 L L L D D1 d D2 1 G 1 D D2 DN R ³ 15 0( 5.9 ) Mounted directly on SITRANS P transmitter for pressure L Mounted on SITRANS P transmitter for pressure or differential pressure and flow Connection to DIN 11851 with screw necks Clamp connection for pipes to BS 4825/3 and o.D. tubes DN Ø D1 Ø D2 H L G1 d 25 38 52 68 128 Rd 52x1/6 mm 40 55 65 74.5 160 Rd 65x1/6 50 68 78 81 170 Rd 78x1/6 65 85 95 89.5 182 Rd 95x1/6 80 110 110 97 182 Rd 110x1/4 100 130 130 107 182 Rd 110x1/4 73.0 Ø D1 Ø D2 H L D (inch) mm (inch) mm (inch) mm (inch) mm (inch) mm (inch) 22.2 (1) 38 (1.5) (1.97) 67 34.9 (1½) 43 (1.69) 65 (2.56) 74.5 (2.93) 146 (5.75) 50.5 (1.98) 47.6 (2) 56 (2.2) (2.95) 79.5 (3.13) 156 (6.14) 64 60.3 (2½) 68 (2.68) 77 (3.03) 80.5 (3.17) 156 (6.14) 77.5 (3.05) (3) 82 (3.23) 91 (3.58) 87.5 (3.44) 156 (6.14) 91 50 75 (2.64) 114 (4.49) 50.5 (1.98) (2.52) (3.58) Quick-release clamp-on seal, dimensions in mm (inch) Siemens FI 01 · 2009 2/181 © Siemens AG 2008 SITRANS P measuring instruments for pressure Remote seals Measuring setups ■ Overview Possible combinations of pressure transmitters and remote seals This section shows examples of typical measuring setups for using SITRANS P pressure transmitters with and without remote seals. 2 Type of installation Pressure transmitters Remote seals A/B 7MF4033 7MF4034 7MF4035 7MF8023 7MF8024 7MF8025 7MF4900 7MF4910 7MF4920 C1 and C2 7MF4233 7MF4234 7MF4235 7MF4900 7MF4910 7MF4920 (vacuum-proof design in each case) 7MF4333 7MF4334 7MF4335 7MF4901 7MF4921 D 7MF4433 7MF4434 7MF4435 7MF4903 7MF4923 When measuring at pressures above atmospheric, the pressure transmitter can also be installed above the connection flange. E 7MF4433 7MF4434 7MF4435 7MF4913 The capillaries between the remote seal and the pressure transmitter should be as short as possible to obtain a good transmission response. G, H and J 7MF4433 7MF4434 7MF4435 7MF4903 7MF4923 Equations for calculating start of scale and full scale are provided for each example. Questionnaires are included to help you select the right combination of remote seal and pressure transmitter. Installation Remote seals of sandwich design are fitted between the connection flange of the measuring point and a dummy flange. Remote seals of flange design are fitted directly on the connection flange of the measuring point. The respective pressure rating of the dummy flange or the flanged remote seal must be observed. The pressure transmitter should be installed below the connection flange (and below the lower connection flange in the case of differential pressure transmitters). This arrangement must be used in the low-pressure range. Offset of measuring range If there is a difference in height between the two connection flanges when measuring with two remote seals, an additional differential pressure will result from the oil filling of the remote seal capillaries. This results in a measuring range offset which has to be taken into account when you set the pressure transmitter. An offset in the measuring range also occurs when combining a remote seal with a transmitter if the remote seal is not installed at the same height as the transmitter. Pressure transmitter output If the level, separation layer or density increase in closed vessels, the differential pressure and hence the output signal of the pressure transmitter also increase. For an inverted relationship between the differential pressure and the output signal, the start-of-scale and full-scale values of the SITRANS P must be interchanged. With open vessels, a rising pressure is usually assigned to an increasing level, separation layer or density. Influence of ambient temperature Temperature differences between the individual capillaries and between the individual remote seals should be avoided. Temperature variations in the area of the measuring setup cause a change in volume of the filling liquid and hence measuring errors. Notes • For the separation layer measurement, the separation layer has to be positioned between the two spigots. Also you must make sure that the level in the container is always above the top spigot. • When measuring density, make sure that the level of the medium remains constant. The level should be above the top spigot. 2/182 Siemens FI 01 · 2009 © Siemens AG 2008 SITRANS P measuring instruments for pressure Remote seals Measuring setups with remote seals ■ Dimensional drawings Types of installation for pressure and level measurements (open vessels) Installation type A Installation type B Installation type A 2 Start-of-scale: pMA = rFL · g · HU - rOil · g · H1 Full-scale: DH DH HO Installation type B HO Start-of-scale: pMA = rFL · g · HU + rOil · g · H1 Full-scale: HU HU H1 pME = rFL · g · HO - rOil · g · H1 H1 Legend pMA pME rFL rOil g HU HO H1 Pressure transmitter Pressure transmitter below the measuring point above the measuring point H1 £ 7 m (23 ft), with halocarbon oil as filling liquid only H1 £ 4 m (13.1 ft) pME = rFL · g · HO + rOil · g · H1 Start-of-scale value to be set Full-scale value to be set Density of medium in vessel Density of filling oil in the capillary to the remote seal Local acceleration due to gravity Start-of-scale value Full-scale value Distance between vessel flange and pressure trans. Types of installation for absolute level measurements (closed vessels) Installation type C1 and C2 Installation type C2 Installation type C1 Start-of-scale: pMA = pSTART + rOil · g · H1 Full-scale: Legend pMA pME pSTART pEND rOil H1 p abs p abs H1 g H1 pME = pEND + rOil · g · H1 Start-of-scale value to be set Full-scale value to be set Start-of-scale value Full-scale value Density of filling oil in the capillary to the remote seal Local acceleration due to gravity Distance between vessel flange and pressure trans. Pressure transmitter for absolute pressure always below the measuring point: H1 ³ 200 mm (7.9 inch) Type of installation for differential pressure and flow measurements Installation type D Filter monitoring Installation type D Start-of-scale: pMA = pSTART - rOil · g · HV Full-scale: H1 HV Legend pMA pME pSTART pEND rOil g HV pME = pEND - rOil · g · HV Start-of-scale value to be set Full-scale value to be set Start-of-scale value Full-scale value Density of filling oil in the capillary to the remote seal Local acceleration due to gravity Distance between the measuring points (spigots) H2 Siemens FI 01 · 2009 2/183 © Siemens AG 2008 SITRANS P measuring instruments for pressure Remote seals Measuring setups with remote seals Types of installation for level measurements (closed vessels) Installation type E Installation type E Start-of-scale: pMA = rFL · g · HU - rOil · g · HV Full-scale: 2 Legend pMA pME rFL rOil DH HV g HU HO HV HO HU Installation type G Installation type H pME = rFL · g · HO - rOil · g · HV Start-of-scale value to be set Full-scale value to be set Density of medium in vessel Density of filling oil in the capillary to the remote seal Local acceleration due to gravity Start-of-scale value Full-scale value Distance between the measuring points (spigots) Installation type J H2 H1 HV H1 DH HO H1 H2 HU H2 Pressure transmitter for differential pressure above the upper measuring point, no vacuum between the measuring points, no vacuum below the lower measuring point H1 £ 7 m (23 ft), with halocarbon oil as filling liquid only H1 £ 4 m (13.1 ft) Installation type G, H and J Start-of-scale: pMA = rFL · g · HU - rOil · g · HV Full-scale: 2/184 pME = rFL · g · HO - rOil · g · HV Siemens FI 01 · 2009 H2 £ 7 m (23 ft), with halocarbon oil as filling liquid only H2 £ 4 m (13.1 ft) Legend pMA pME rFL rOil Start-of-scale value to be set Full-scale value to be set Density of medium in vessel Density of filling oil in the capillary to the remote seal g HU HO HV Local acceleration due to gravity Start-of-scale value Full-scale value Distance between the measuring points (spigots) © Siemens AG 2008 SITRANS P measuring instruments for pressure Remote seals Measuring setups without remote seals ■ Overview Notes • For the separation layer measurement, the separation layer has to be positioned between the two spigots. Also you must make sure that the level in the container is always above the top spigot. • When measuring density, make sure that the level of the medium remains constant. The level should be above the top spigot 2 ■ Dimensional drawings Pressure transmitters for differential pressure, for flanging Measuring setups for open containers Level measurement Start-of-scale: pMA = r · g · HU Full-scale value Ho r Start-of-scale value Hu Full-scale: pME = r · g · HO Legend pMA pME r g HU HO Start-of-scale value to be set Full-scale value to be set Density of medium in vessel Local acceleration due to gravity Start-of-scale value Full-scale value + Separation layer measurement Start-of-scale: pMA = g · (HU · r1 + (HO - HU) · r2) Constant level = full-scale value Separation layer Ho Start-of-scale value r2 r1 Hu Full-scale: pME = r1 · g · HO Legend pMA pME r1 r2 g HU HO Start-of-scale value to be set Full-scale value to be set Density of heavier liquid Density of lighter liquid Local acceleration due to gravity Start-of-scale value Full-scale value + Density measurement Start-of-scale: pMA = rMIN · g · HO Constant level Ho r Full-scale: pME = rMAX · g · HO Legende pMA pME rMIN rMAX g HO Start-of-scale value to be set Full-scale value to be set Minimum density of medium in vessel Maximum density of medium in vessel Local acceleration due to gravity Full-scale value in m + Siemens FI 01 · 2009 2/185 © Siemens AG 2008 SITRANS P measuring instruments for pressure Remote seals Measuring setups without remote seals Measuring setups for closed containers Level measurement, Version 1 Static pressure 2 Start-of-scale: DpMA = r · g · HU Gas-filled negative pressure line Maximum level Full-scale value Start-of-scale value Full-scale: DpME = r · g · HO Legend DpMA DpME r g HU HO Start-of-scale value to be set Full-scale value to be set Density of medium in vessel Local acceleration due to gravity Start-of-scale value Full-scale value Ho Hu r Transmitter reference line Maximum level Static pressure Separation layer measurement Static pressure Constant level Start-of-scale: DpMA = g · (HU · r1 + (HO - HU) · r2 - HV · r'2) Full-scale: Max. separation layer Legend DpMA DpME r1 Full-scale value Start-of-scale value r 2 r' 2 Ho Transmitter reference line 2/186 Siemens FI 01 · 2009 r2 r'2 g HU HO HV r 1 Hu Hv DpME = g · (HO · r1 - HV · r'2) Start-of-scale value to be set Full-scale value to be set Density of heavier liquid with separation layer in vessel Density of lighter liquid with separation layer Density of liquid in the negative pressure line (corresponding to the temperature existing there) Local acceleration due to gravity Start-of-scale value Full-scale value Distance between the measuring points (spigots) s © Siemens AG 2008 Questionnaire Checking of transmitter/remote seal combinations * Customer:___________________ * Plant: ___________________ * Ordering code:________________ * Ordering department: _____ * Transmitter Order No.: 7MF 4 Tag. No.: _____________________ Item No.: _____________________ Person responsible: ___________ Phone: _____________________ –1 –1 2 Order No. of transmitter known? Yes No * Order No. of remote seal: * 7MF 4 9 – – –Z Suffixes _______________________ Suffixes _______________________ * Or without Order No.: Process connection * Standard: ________________________ * Nominal diameter: ________________________ * Nominal pressure: ________________________ * Constructional design: Sandwich-type rem. seal Flanged remote seal Quick-release remote seal Clamp-on seal Other.: ______________ * Connection: Direct connection Capillary on one side; connection to: + side – side Capillaries on both sides; Capillary length: ___ m * Vacuum-proof design Yes No * Wetted parts materials: ________________________ * Tube: No Yes, ___mm long * Filling liquid ________________________ * Miscellaneous ________________________ Calculation of measuring range necessary? No * Range to be set: * (without calculation) Start-of-scale: _________ mbar ( 4 mA) Full-scale: _________ mbar (20 mA) * Required measuring accuracy: < . % of set span per Error: _________ : _________ 10 V change in : _________ temperature Please fill in this questionnaire and enclose with every order! Yes * Medium ____________________________ * Density of medium: _______ * Temperature of medium: kg/m3 Normal ________ °C Minimum ________ °C Maximum________ °C * Ambient temperature on capillaries: Normal ________ °C Minimum ________ °C Maximum________ °C * Ambient temperature on transmitter: Normal ________ °C Minimum ________ °C Maximum________ °C * Operating pressure referred to absolute zero: ____ bar a * Does a vacuum occur during startup? No Yes If yes, associated temperature of medium: ________ °C A B C1 C2 D * Installation type, see pages 2/183 and 2/184 E Checked: Name: Department: Date: G H J * Measuring: With install. types A, B, C1, C2 and D: from ___ to ___ mbar range With install. types A, B, G, H and J: HU = ___ mm; HO = ___ mm * Dimensions: With install. types A, B, C1 and C2: H1 = ___ mm With install. types D, G, H and J: HV = ___ mm * Start-of-scale value following calculation:_________ mbar ( 4 mA) * Full-scale value following calculation:_________ mbar (20 mA) * Associated span: _________ mbar < . % of set span per 10 K * Error to be expected: _________ _________ change in temperature *) Values must be entered here! Siemens FI 01 · 2009 2/187 © Siemens AG 2008 s Questionnaire for hydrostatic level measurements Order date: _______________________________________________ Processing date: __________________________________________ 2 Ordering code (customer): _________________________________ Ordering code (supplier): __________________________________ Customer reference:_______________________________________ Measuring point: __________________________________________ Position:__________________________________________________ Dimensions: ______________________________________________ Pressure: bar Temperature: K Measuring range: cm (please mark with cross) °C m Order No. of transmitter 1): 7 M F 4 – – –Z Y01 The different pressures and temperatures (densities) in the vessel and in the reference column result in an offset in the start-of-scale and full-scale values. The calibration data are determined in addition. It is also checked whether – as a result of the range offset – the ordered transmitter is suitable for this measurement. Please supply the following characteristic data so that we can calculate the measuring range, start-of-scale value, full-scale value and calibration data: Please mark type of boiler with a cross: Closed1) Open or not under pressure2) Medium ____________________ Licensed boiler pressure (absolute) Operating pressure (absolute) _______________ bar Lowest _______________ bar Normal3) _______________ bar Highest _______________ bar Temperature of reference column (cold) _______________ K Distance between measuring points (dimension according to sketch) HV = _________ m Measuring range4) = start-of-scale value to full-scale value Start-of-scale value HU =___________ m Full-scale value HO =___________ m Position of equalizing vessel above bottom measuring point if different from HV Please mark pressure correction of level with a cross: _______________ m No Yes4) 1) 2) 3) 4) 2/188 Siemens FI 01 · 2009 Reference line filled with condensation! Falling differential pressure with increasing level. Reference line without gas or filled with gas (air). Rising differential pressure with increasing level. If not specified otherwise, this value is assumed as the calculation pressure of the level meter. The input signal (differential pressure) depends on the density (pressure and temperature). The influence is practically negligible for a lowest liquid level of 20 to 30% of the distance between the measuring points. If a pressure correction of the level is required, the measuring range must be the same as the distance between the measuring points, and the transmitter is designed for the calculation pressure of 1 bar (absolute). Pressure correction means: the static pressure and the temperature are measured separately and calculated by a correction computer or measured-value computer. © Siemens AG 2008 s Questionnaire (suitable for US market) Checking of transmitter/remote seal combinations * Customer:___________________ * Plant: ___________________ * Ordering code:________________ * Ordering department: _____ * Transmitter Order No.: 7MF 4 Tag. No.: _____________________ Item No.: _____________________ Person responsible: ___________ Phone: _____________________ –1 –1 2 Order No. of transmitter known? Yes No * Order No. of remote seal: * 7MF 4 9 – – –Z Suffixes _______________________ Suffixes _______________________ * Or without Order No.: Process connection * Standard: ________________________ * Nominal diameter: ________________________ * Nominal pressure: ________________________ * Constructional design: Sandwich-type rem. seal Flanged remote seal Quick-release remote seal Clamp-on seal Other.: ______________ * Connection: Direct connection Capillary on one side; connection to: + side – side Capillaries on both sides; Capillary length: ___ ft * Vacuum-proof design Yes No * Wetted parts materials: ________________________ * Tube: No Yes, __inch long * Filling liquid ________________________ * Miscellaneous ________________________ Calculation of measuring range necessary? No * Range to be set: * (without calculation) Start-of-scale: _________ psi ( 4 mA) Full-scale: _________ psi (20 mA) * Required measuring accuracy: < . % of set span per Error: _________ : _________ 18 °F change in : _________ temperature Please fill in this questionnaire and enclose with every order! Yes * Medium ____________________________ * Density of medium: _______ * Temperature of medium: kg/m3 Normal ________ °F Minimum ________ °F Maximum ________ °F * Ambient temperature on capillaries: Normal ________ °F Minimum ________ °F Maximum ________ °F * Ambient temperature on transmitter: Normal ________ °F Minimum ________ °F Maximum ________ °F * Operating pressure referred to absolute zero: ____ psiabs * Does a vacuum occur during startup? No Yes If yes, associated temperature of medium: ________ °F A B C1 C2 D * Installation type, see pages 2/183 and 2/184 E Checked: Name: Department: Date: G H J * Measuring: With install. types A, B, C1, C2 and D: from ___ to ___ psi range With install. types A, B, G, H and J: HU = ___ inch; HO = ___ inch * Dimensions: With install. types A, B, C1 and C2: H1 = ___ inch With install. types D, G, H and J: HV = ___ inch * Start-of-scale value following calculation: _________ psi ( 4 mA) * Full-scale value following calculation: _________ psi (20 mA) * Associated span: _________ psi < . % of set span per 18 °F * Error to be expected: _________ _________ change in temperature *) Values must be entered here! Siemens FI 01 · 2009 2/189 © Siemens AG 2008 SITRANS P measuring instruments for pressure Fittings Technical description ■ Overview Classification according to pressure equipment directive (DGRL 97/23/EC): All 21-off fittings can be secured onto walls, racks (72 mm grid) and vertical and horizontal pipes. 2 This offers the advantage when assembling a plant that the shutoff fittings can be secured first and the lines for the medium and differential pressure connected to them. It is then possible to check all connections for leaks and to blow out or flush the pipes in order to remove dirt (welding residues, shavings etc.). The measuring instruments can be screwed onto the shut-off fittings right at the end when all piping has been completed. If an instrument has to be removed for maintenance, the fittings and pipes remain as they are. It is only necessary to close the valves – the instrument can then be removed, and refitted following maintenance. For gases of fluid group 1 and liquids of fluid group 1; compliance with requirements of article 3, paragraph 3 (sound engineering practice).Siemens FI 01 · 2009 New standard DIN EN 61518 The flange connection between transmitter and valve manifold was modified in the new standard DIN EN 61518. The only connection thread approved for use in the process flanges of the pressure transmitter is 7/16-20 UNF. The valve manifolds for M12 screws, including the accessory sets, have therefore been deleted. Material acceptance test certificate to EN 10204-3.1 If a material acceptance test certificate to EN 10204-3.1 is required when ordering valve manifolds or shut-off fittings, please note that a single certificate is sufficient for each ordered item type. This means that you will only be charged for one certificate in the cost calculations. ■ Pressure transmitters with shut-off fittings - mounting examples SITRANS P transmitter for gage pressure with double shut-off valve, SITRANS P pressure transmitter with multiway cock or 3-spindle valve manifold SITRANS P pressure transmitter for differential pressure, mounted in protective box (available on request) SITRANS P transmitter for differential pressure with 3-way valve manifold, 3-spindle valve manifold or valve manifold combination DN 5/DN 8 SITRANS P pressure transmitter mounted on valve combination "Monoflange" for direct connection to flanges (available on request) 2/190 Siemens FI 01 · 2009 © Siemens AG 2008 SITRANS P measuring instruments for pressure Fittings Selection aid ■ Selection of available shut-off valves Transmitters Shut-off valves for general applications Page Shut-off valves for special applications Relative and absolute presShut-off valves/double shutsure transmitters with process off valves to DIN 16270, connection G½" male thread DIN 16271 and DIN 16272 e.g. • SITRANS P, Z series 7MF1564-.....-.A.. • SITRANS P300 7MF802.-...0.-.... • SITRANS P DS III series 7MF403.-...0.-.... and 7MF423.-...0.-.... 2/193 Double shut-off valve DN 5 2/196 for crossover ½-NPT-F to G½ nipple connection 7MF9011-4EA Double shut-off valve DN 5 7MF9011-4FA and 7MF9011-4GA 2 2-spindle valve manifold 2/216 DN 5 for installation in protective boxes 7MF9412-1B 2-way valve manifolds, DN 5, forged version 7MF9401-2J. and 7MF9401-2K. Relative and absolute pressure transmitter with G½"-14 NPT female thread • e.g. • SITRANS P Z series 7MF1564-.....-.H.. • SITRANS P300 7MF802.-...1.-.... • SITRANS P DS III series 7MF403.-...1.-.... and 7MF423.-...1.-.... Page 2/198 2/196 Double shut-off valve 2/196 DN 5 for process connection ½-NPT 7MF9011-4DA Absolute pressure transmitter 2-spindle valve manifold DN 5 2/201 with process connection to 7MF9411-5A. IEC 61518 e.g. • SITRANS P DS III series 7MF433.-... 2-spindle valve manifold 2/216 DN 5 for installation in protective boxes 7MF9412-1C. 2-way valve manifolds, DN 5, forged version 7MF9401-2E. and 7MF9401-2F. 2/198 Siemens FI 01 · 2009 2/191 © Siemens AG 2008 SITRANS P measuring instruments for pressure Fittings Selection aid 2 Transmitters Shut-off valves for general applications Differential pressure transmitter with process connection to IEC 61518 e.g. • SITRANS P DS III series 7MF443.-... and 7MF453.-... For 3/5-spindle valve manifold 2/201 DN 5 7MF9411-5B. and 7MF9411-5C. PN 100 multiway cocks 7MF9004-... 2/192 Siemens FI 01 · 2009 Page 2/204 Shut-off valves for special applications Page 3-way valve manifolds, DN 5, forged version 7MF9410-1.. 2/206 5-way valve manifolds, DN 5, forged version 7MF9410-3.. 2/206 3-way valve manifolds, DN 8, forged version 7MF9416-1.. and 7MF9416-2.. 2/209 Valve manifold combination DN 5/DN 8 for vapor measurement 7MF9416-6.. 2/212 Valve manifold combination DN 8 for vapor measurement 7MF9416-4.. 2/214 3- and 5-spindle valve manifolds for DN 5 for installation in protective boxes 7MF9412-1D. and 7MF9412-1E. 2/216 3- and 5-spindle valve manifolds for vertical differential pressure lines 7MF9413-1.. 2/220 Low-pressure multiway cock 7MF9004-4.. 2/223 © Siemens AG 2008 SITRANS P measuring instruments for pressure Fitttings - Shut-off valves for gage and absolute pressure transmitters Shut-off valves to DIN 16270, DIN 16271 and DIN 16272 ■ Overview Order No. Selection and Ordering data Shut-off valves, form B, DIN 16270 without test collar, pipe union with ferrule 12 S DIN EN ISO 8484-1, without certificate Material Valve housing Maximum permissible working pressure P250GH (mat. No. 1.0460) 400 bar 7MF9401-8AB X 6 CrNiMoTi 17 12 2 400 bar (mat. No. 1.4571/316Ti) 7MF9401-8AC 2 Shut-off valves, form B, DIN 16271 with test collar, pipe union with ferrule 12 S DIN EN ISO 8484-1, without certificate Transmitter for pressure with double shut-off valve 7MF9401-... The shut-off valves for pressure gages are used to shut off the line of the measured medium when dealing with aggressive and non-aggressive gases, vapors and liquids. ■ Design A water trap must be connected upstream of the shut-off valve in the case of temperatures of the medium above 120 °C. The shut-off valves form B have a shaft with which they can be secured on an instrument bracket. An adapter is therefore not required to secure these valves. The vent/test connection can be shut off separately with the double shut-off valves DN 5. This permits checking of the zero on the pressure gage. In addition, the characteristic of the pressure gage can be checked using an external pressure source. Material Valve housing Maximum permissible working pressure P250GH (mat. No. 1.0460) 400 bar 7MF9401-8BB X 6 CrNiMoTi 17 12 2 400 bar (mat. No. 1.4571/316Ti) 7MF9401-8BC Double shut-off valves, form B, DIN 16272 with test collar, connection shank, without certificate Material Valve housing Maximum permissible working pressure CW614N (CuZn39Pb3) 250 bar (mat. No. 2.0402) 7MF9401-7DA P250GH (mat. No. 1.0460) 400 bar 7MF9401-7DB X 6 CrNiMoTi 17 12 2 400 bar (mat. No. 1.4571/316Ti) 7MF9401-7DC Double shut-off valves, form B, DIN 16272 with test collar, pipe union with ferrule 12 S DIN EN ISO 8484-1, without certificate Material Valve housing Maximum permissible working pressure Shut-off valves, form B, DIN 16270 P250GH (mat. No. 1.0460) 400 bar 7MF9401-8DB without test collar, connection shank, without certificate X 6 CrNiMoTi 17 12 2 400 bar (mat. No. 1.4571/316Ti) 7MF9401-8DC Selection and Ordering data Material Valve housing Order No. Maximum permissible working pressure Accessories CW614N (CuZn39Pb3)250 bar (mat. No. 2.0402) 7MF9401-7AA P250GH (mat. No. 1.0460) 400 bar 7MF9401-7AB X 6 CrNiMoTi 17 12 2 400 bar (mat. No. 1.4571/316Ti) 7MF9401-7AC Factory test certificate EN 10204–2.2 7MF9000-8AB Material acceptance test certificate EN 10204-3.1 7MF9000-8AD Instrument bracket, see page 2/197. Shut-off valves, form B, DIN 16271 with test collar, connection shank, without certificate Material Valve housing Maximum permissible working pressure CW614N (CuZn39Pb3)250 bar (mat. No. 2.0402) 7MF9401-7BA P250GH (mat. No. 1.0460) 400 bar 7MF9401-7BB X 6 CrNiMoTi 17 12 2 400 bar (mat. No. 1.4571/316Ti) 7MF9401-7BC Siemens FI 01 · 2009 2/193 © Siemens AG 2008 SITRANS P measuring instruments for pressure Fitttings - Shut-off valves for gage and absolute pressure transmitters Shut-off valves to DIN 16270, DIN 16271 and DIN 16272 ■ Characteristic curves Operating pressure Steel or stainless steel version 400 bar at 120 °C 350 bar at 200 °C 300 200 Brass version 250 bar at 120 °C 200 bar at 200 °C 100 0 0 100 200 300 400 °C Operating temperature Permissible operating pressure as a function of the permissible operating temperature ■ Dimensional drawings 18 A 120 ± 5 63 28 diam. 26 h11 C 20 20 B 20 34 diam. 6 D A B C D Connection on device side: to DIN 16 284, G½, SW 27 Connection on measurement side: connection shank to DIN EN 837-1, G½ Connection on measurement side: pipe union with ferrule 12 mm diam., S series, to DIN EN ISO 8434-1 Connection on test collar (with sealing cap): thread M20x1,5 Shut-off valve, form B, dimension drawing, dimensions in mm 28 18 approx. 90 approx. 85 A diam. 26 h11 SW 27 B diam. 6 20 20 63 120 ± 5 45 C D A B C D 20 2 bar 400 Connection on device side: to DIN 16 284, G½, SW 27 Connection on measurement side: connection shank to DIN EN 837-1, G½ Connection on measurement side: pipe union with ferrule 12 mm diam., S series, to DIN EN ISO 8434-1 Connection on test collar (with protective cap): thread M20x1,5 Double shut-off valve, form B, dimension drawing, dimensions in mm 2/194 Siemens FI 01 · 2009 © Siemens AG 2008 SITRANS P measuring instruments for pressure Fitttings - Shut-off valves for gage and absolute pressure transmitters Angle adapter ■ Overview ■ Dimensional drawings *® É ၂ É *® 2 P300 pressure transmitter with shut-off valve and angle adapter Angle adapter, dimensions in mm The angle adapter enables pressure transmitters with top displays to be read from the front. Selection and Ordering data Order No. Angle adapters 7MF9401-7WA Material: X 12 CrNiMoTi 17 12 2 (mat. No. 1.45714/316Ti), max. permissible operating pressure 400 bar Accessories Factory test certificate EN 10204–2.2 7MF9000-8AB Material acceptance test certificate EN 10204-3.1 7MF9000-8AD ■ Characteristic curves Operating pressure bar 400 300 Design stainless steel 400 bar at 120 °C 350 bar at 200 °C 200 100 0 0 100 200 300 400 °C Operating temperature Permissible operating overpressure as a function of the permissible operating temperature Siemens FI 01 · 2009 2/195 © Siemens AG 2008 SITRANS P measuring instruments for pressure Fitttings - Shut-off valves for gage and absolute pressure transmitters Double shut-off valves A B C 300 18 33 63.5 100.5 17 diam. 31.75 6.4 approx. 90 Connection on device side: nipple to DIN 16 284, G½, SW 27 Connection on measurement side: ½-14 NPT Vent and test connection: ¼-18 NPT 100 ½-14 NPT A 0 100 200 300 400 °C Operating temperature ¼-18 NPT C 110 Permissible operating pressure as a function of the permissible operating temperature Order No. Selection and Ordering data Double shut-off valves DN 5 B ½-14 NPT Material: X 6 CrNiMoTi 17 13 2 (mat. No. 1.4404/316L), max. permissible working pressure 420 bar; • Sleeve-sleeve 7MF9011-4DA • Sleeve-nipple connection 7MF9011-4EA • Sleeve-collar 7MF9011-4FA • Collar-collar 7MF9011-4GA Accessories Factory test certificate EN 10204–2.2 7MF9000-8AB Material acceptance test certificate EN 10204-3.1 7MF9000-8AD A B C Connection on device side: ½-14 NPT Connection on measurement side: ½-14 NPT Vent and test connection: ¼-18 NPT Double shut-off valve DN 5 (sleeve-collar) 7MF9011-4FA, dimensions in mm DSSUR[ ~137 ■ Dimensional drawings C 12 31 60 A B C B 7 diam. 6.4 137 C B 137 31.75 17 50 A 33 63.5 approx. 118 25.5 A DSSUR[ 0 B Double shut-off valve DN 5 (sleeve-nipple) 7MF9011-4EA, dimensions in mm 420 bar at 120 °C 350 bar at 200 °C 200 6 31 60 12 approx. 118 bar 400 18.5 7 C ■ Characteristic curves Operating pressure 2 A diam. 7 approx. 25.5 58 The double shut-off valves DN 5 are suitable for pressure gages and pressure transmitters and available in 4 versions: • Sleeve-collar • Sleeve-sleeve • Sleeve-nipple • Collar-collar 50 ■ Overview approx. 90 Connection on device side: ½-14 NPT Connection on measurement side: ½-14 NPT Vent and test connection: ¼-18 NPT Double shut-off valve DN 5 (sleeve-sleeve) 7MF9011-4DA, dimensions in mm A B C Connection on device side : ½-14 NPT Connection on measurement side: ½-14 NPT Vent and test connection: ¼-18 NPT Double shut-off valve DN 5 (collar-collar) 7MF9011-4GA, dimensions in mm 2/196 Siemens FI 01 · 2009 © Siemens AG 2008 SITRANS P measuring instruments for pressure Fitttings - Shut-off valves for gage and absolute pressure transmitters Accessories for shut-off valves / double shut-off valves ■ Overview ■ Overview The mounting set is suitable for the double shut-off valves 7MF9011-4.A and for wall, rack and pipe mounting. Order No. Selection and Ordering data Mounting set for shut-off valves • 7MF9011-4DA und -4EA made of stainless steel, scope of delivery: 1x mounting bracket, 2x hexagon screws M6x40, 1x mounting clip, 2x washers 8.4 to DIN 125; 2x hexagon nuts 8.4 to DIN EN 24032 7MF9011-8AB • 7MF9011-4FA und -4GA made of stainless steel, scope of delivery: 1x mounting bracket, 2x hexagon screws M6x10, 1x mounting clip, 2x washers 8.4 to DIN 125; 2x hexagon nuts 8.4 to DIN EN 24032 7MF9011-8AC The instrument brackets are needed to mount the following units: • Pressure gages with threaded connection at the bottom • Shut-off valves to DIN 16270, DIN 16271 and DIN 16272 (7MF9401-7.. and 7MF9401-8..) Order No. Selection and Ordering data Instrument bracket, form H, DIN 16281 made of aluminium alloy, painted black, for wall mounting, screw-type bracket cover • Projection length 60 mm • Projection length 100 mm M56340-A0046 M56340-A0047 Instrument bracket, form A, DIN 16281 made of annealed cast iron, galvanized and primed for mounting on a wall or rack or or on a sectional rail (horizontal/vertical); Screw-type bracket cover M56340-A0053 Instrument bracket, form A, DIN 16281 made of annealed cast iron, galvanized and primed with pipe clamp for mouting on a pipe (horizotal/vertical) Screw-type bracket cover ■ Dimensional drawings M56340-A0079 18 5 10 6: 56 (60) 100 (160) 65 28 ■ Dimensional drawings o7 Mounting bracket (7MF9011-8AB) for shut-off valves 7MF9011-4DA and 7MF9011-4EA for wall, rack or pipe mounting, dimensions in mm o26 h11 Instrument bracket form H, for wall mounting, M56340-A0046/-A0047, dimensions in mm 100 72 10 SW10 hex. 10 11 85 50 72 90 91 28 34 o26 100 h11 4 6.5 R30 Ø60.3 M8 85 25 72 90 72 <_ o6 3 o1 1 65 Instrument bracket form A, wall or pipe mounting, M56340-A0053/-A0079, dimensions in mm Mounting bracket (7MF9011-8AC) for shut-off valves 7MF9011-4FA and 7MF9011-4GA for wall, rack or pipe mounting, dimensions in mm Siemens FI 01 · 2009 2/197 2 © Siemens AG 2008 SITRANS P measuring instruments for pressure Fitttings - Shut-off valves for gage and absolute pressure transmitters 2-way valve manifolds DN 5 ■ Overview ■ Function The characteristic of the pressure measuring instrument or pressure transmitter can be tested through the test connection. A pressure gage for local display can be connected to the test connection. 2 The two-way valve manifold DN 5 can be used in addition to shut off and vent the line with the measured medium. ■ Accessories The two-way valve manifold DN 5 (7MF9401-2..) is used to shut off and vent the line with the measured medium, and to test the connected pressure gage or transmitter. ■ Benefits Accessory set for 2-way valve manifold DN 5 for flanging • A31: 2 screws 7/16-20 UNF x 21/8 inch to ASME B18.3, 1 flat gasket • A34: 2 screws 7/16-20 UNF x 21/8 inch to ASME B18.3, 1 O-ring (FPM 90) • A11: 2 screws M10x55 to DIN EN 4762, 2 washers, 1 flat gasket • A15 (suitable for oxygen): 2 screws M10x55 to DIN EN 4762, 2 washers, 1 flat gasket • A16: 2 screws M10x55 to DIN EN 4762, 2 washers, 1 flat gasket (FPM 90) Note: M10 screws only permissible up to PN 160! • Available for aggressive and non-aggressive liquids and gases • Two connection versions available - For flanging to pressure transmitters - With nipple for connection of pressure gages and pressure transmitters for pressure • Max. working pressure 420 bar, with version for oxygen max. 100 bar ■ Application The 2-way valve manifold is available in versions for aggressive and non-aggressive liquids and gases. Mounting plates are available for wall mounting, for securing to mounting racks or for pipe mounting. ■ Design The 2-way valve manifold DN 5 has 3 connections: • A process connection (pipe union with ferrule Ø 12 mm) • A connection for a pressure gage (flange or nipple) • A test connection (thread G3/8) The 2-fold valve manifold DN 5 also has an operating valve and a test valve, each with an internal spindle thread. Materials used 2-way valve manifold DN 5 for flanging to pressure transmitters For non-aggressive liquids and gases For aggressive liquids and gases Component Material Mat. No. Material Housing 1.0460 X6 1.4571/ CrNiMoTi 316Ti 17 12 2 P250GH Head parts C 35 1.0501 Spindles X 12 CrMoS 17 1.4104 Cones X 35 CrMo 17 hardened and tempered 1.4122 Valve seats X 6 CrNiMoTi 17 12 2 1.4571/316Ti Packings PTFE - 2/198 Siemens FI 01 · 2009 PTFE Mat. No. - Washers Ø 10.5 to DIN 125 Flat gaskets made of PTFE, max. 420 bar, 80 °C O-ring to DIN 3771, 20 x 2.65 - S – FPM90, max. 420 bar, 120 °C Mounting plate Made of electrogalvanized sheet-steel • M11: For wall mounting or for securing on rack (72 mm grid) Scope of delivery: - 1 mounting plate with bolts for mounting on valve manifold • M12: For pipe mounting Scope of delivery: - 1 mounting plate M11 - 2 pipe brackets with nuts and washers for pipes with max. Ø 60.3 mm Valve manifold 100 bar, suitable for oxygen • S12: (only in combination with versions for aggressive liquids and gases): Suitable for oxygen © Siemens AG 2008 SITRANS P measuring instruments for pressure Fitttings - Shut-off valves for gage and absolute pressure transmitters 2-way valve manifolds DN 5 Selection and Ordering data Order No. Selection and Ordering data 2-way valve manifold DN 5 for flanging to pressure transmitters, max. working pressure 420 bar, weight 1.85 kg (order accessory set and mounting plate with Order code), without certificate 7 MF 9 4 0 1 - 77A Further designs1) 2E • for aggressive liquids and gases 2F for fitting to pressure gages or pressure transmitters for pressure, with nipple connection to DIN 16284, max. working pressure 420 bar, weight 1.8 kg (order mounting plate with Order code)1) • for non-aggressive liquids and gases 2J • for aggressive liquids and gases 2K Accessories Factory test certificate EN 10204–2.2 7MF9000-8AB Material acceptance test certificate EN 10204-3.1 7MF9000-8AD For suitable seals, see page 2/228. Order No. Please add "-Z" to Order No. and specify Order code. • for non-aggressive liquids and gases 1) Order code 2 Accessory set to EN (required for flanging, weight 0.2 kg) 2x screws 7/16-20 UNF x 21/8 inch to ASME B18.3; chromized steel 1x gasket made of PTFE, max. permissible 420 bar, 80 °C A31 7MF9001-5CC 2x screws 7/16-20 UNF x 21/8 inch to ASME B18.3; chromized steel 1x O-ring to DIN 3771, 20 x 2.65 - S - FPM90, max. permissble 420 bar, 120 °C A34 7MF9401-5AA • Standard design A11 7MF9001-6AD • Version for oxygen A15 7MF9001-6AE 2x screws M10x55 to DIN EN ISO 4762; chromized steel 2x washers Ø 10.5 mm to DIN 125; 1x O-ring to DIN 3771, 20 x 2.65 - S - FPM90, max. permissble 420 bar, 120 °C A16 7MF9001-6AF for wall mounting or for securing on rack (72 mm grid), weight 0.5 kg Scope of delivery: 1 mounting plate with bolts for mounting on valve manifold M11 7MF9006-6EA for pipe mounting, weight 0.7 kg Scope of delivery: 1x mounting plate M11, 2x pipe brackets with nuts and washers (for pipe with max. Ø 60.3 mm) M12 7MF9006-6GA Accessory set to DIN2) (required for flanging3), weight 0.2 kg) 2x screws M10x55 to DIN EN ISO 4762; chromized steel 2x washers Ø 10.5 to DIN 125; 1x gaskets made of PTFE, max. permissible 420 bar, 80 °C Mounting plate for valve manifold, made of electrogalvanized sheet-steel Valve manifold 100 bar Suitable for oxygen, only for 7MF9401-2F. and 7MF9401-2K. 1) 2) 3) S12 When ordering accessory set or mounting together with the 2-way valve manifold, please use Order code; otherwise use Order No. Flange connections to DIN 19213 only permissible up to PN 160! Only required for versions 7MF9401-2E. und -2F. Siemens FI 01 · 2009 2/199 © Siemens AG 2008 SITRANS P measuring instruments for pressure Fitttings - Shut-off valves for gage and absolute pressure transmitters 2-way valve manifolds DN 5 ■ Characteristic curves 300 200 100 0 0 100 200 300 400 °C Operating temperature 2-way valve manifold DN 5, permissible working pressure as a function of the permissible working temperature ■ Dimensional drawings 19,5 2 51 1 59 C 41 Ø12 B 7 M10, 12 2-way valve manifold DN 5 (7MF9401-2J/-2K) for connection to pressure gages and pressure transmitters, dimensions in mm 41,3 65 100 34 32,5 2 Operating pressure bar 400 A 72 25 A Process connection, Pipe union with ferrule, diameter 12 mm, S series to DIN 2353 B Connection for pressure gauge: flange conn. to DIN EN 61 518, Form A C Test connection: thread G3/8 1 Operating valve 2 Test valve Valve design: Internal spindle thread 2-way valve manifold DN 5 (7MF9401-2E/-2F) for flanging, dimensions in mm Mounting plate 7MF9006-6.. (M11, M12) for valve manifold, dimensions in mm ■ Schematics B C A A B C Process connection Transmitter connection Test and blow-out connection Connection diagram of the 2-way valve manifolds 2/200 Siemens FI 01 · 2009 © Siemens AG 2008 SITRANS P measuring instruments for pressure Fitttings - Shut-off valves for differential pressure transmitters 2-, 3- and 5-spindle valve manifolds DN 5 ■ Overview Selection and Ordering data Order No. Valve manifolds DN 5 for liquids and gases, for flanging to pressure transmitters for absolute and differential pressure, max. working pressure 420 bar (order accessory set with Order code), without certificate 7 MF 9 4 1 1 - 77A • 2-spindle valve manifold 5A • 3-spindle valve manifold 5B • 5-spindle valve manifold 5C Accessories Factory test certificate EN 10204–2.2 7MF9000-8AB Material acceptance test certificate EN 10204-3.1 7MF9000-8AD Order code Order No. 2x screws 7/16-20 UNF x 1¾ inch to ASME B18.2.1; chromized steel 1x gasket made of PTFE, max. permissible 420 bar, 80 °C K35 7MF9411-7DB 2x screws 7/16-20 UNF x 1¾ inch to ASME B18.2.1; stainless steel 1x gasket made of PTFE, max. permissible 420 bar, 80 °C K45 7MF9411-7DC 4x screws 7/16-20 UNF x 1¾ inch to ASME B18.2.1; chromized steel 2x flat gaskets made of PTFE, max. permissible 420 bar, 80 °C K36 7MF9411-5DB 4x screws 7/16-20 UNF x 1¾ inch to ASME B18.2.1; stainless steel 2x flat gaskets made of PTFE, max. permissible 420 bar, 80 °C K46 7MF9411-5DC 2x screws M10x45 to DIN EN 24014; chromized steel 2x washers Ø 10.5 mm to DIN 125; 1x gasket made of PTFE, max. permissible 420 bar, 80 °C K15 7MF9411-7BB 2x screws M10x45 to DIN EN 24014; stainless steel 2x washers Ø 10.5 mm to DIN 125, stainless steel; 1x gasket made of PTFE, max. permissible 420 bar, 80 °C K25 7MF9411-7BC Selection and Ordering data Further designs1) The 2-spindle, 3-spindle and 5-spindle valve manifolds 7MF9411-5.. are for pressure transmitters for absolute pressure or differential pressure. The valve manifolds are used to shut off the differential pressure lines and to check the pressure transmitter zero. The 2-spindle and the 5-spindle valve manifold enable in addition venting on the transmitter side and checking of the pressure transmitter characteristic. ■ Benefits • Max. working pressure 420 bar • Each available in version for oxygen ■ Application The spindle valve manifolds DN 5 are designed for liquids and gases Each is available in a version for oxygen on request ■ Design All versions of the valve manifolds have a process connection ½14 NPT. The connection for the pressure transmitter is always designed as a flange connection to EN 61518, form B . The 2spindle and the 5-spindle valve manifold have in addition a vent and test connection ¼-18 NPT. The valves have an external spindle thread. Materials used Component Material Mat. No. Housing X 2 CrNiMo 17 13 2 1.4404/316L Cones X 6 CrNiMoTi 17 12 2 1.4571/316Ti Spindles X 2 CrNiMo 18 10 1.4404/316L Head parts X 5 CrNiMo 18 10 1.4401/316 Packings PTFE - ■ Function Please add "-Z" to Order No. and specify Order code. Accessory set to EN (connection between valve manifold and pressure transmitter) for valve manifold 7MF9411-5A. for valve manifold 7MF9411-5B. and -5C. Accessory set to DIN2) (connection between valve manifold and pressure transmitter) for valve manifold 7MF9411-5A. Functions of all valve manifolds: • Shutting off the differential pressure lines • Checking the pressure transmitter zero Additional functions of the 2-spindle and 5-spindle valve manifolds through the vent and test connection: • Venting on the transmitter side • Checking the pressure transmitter characteristic Siemens FI 01 · 2009 2/201 2 © Siemens AG 2008 SITRANS P measuring instruments for pressure Fitttings - Shut-off valves for differential pressure transmitters 2-, 3- and 5-spindle valve manifolds DN 5 Order code Order No. Further designs1) Accessory set for 2-, 3- and 5-spindle valve manifolds Please add "-Z" to Order No. and specify Order code. 2 for valve manifolds 7MF9411-5B. and -5C. 4x screws M10x45 to DIN EN 24014; chromized steel 4x washers Ø 10.5 mm to DIN 125; 2x flat gaskets made of PTFE, max. permissible 420 bar, 80 °C Flange connection with M10 screws only permissible up to PN 160. K16 4x screws M10x45 to DIN EN 24014; stainless steel 4x washers Ø 10.5 mm to DIN 125, stainless steel; 2x flat gaskets made of PTFE, max. permissible 420 bar, 80 °C Flange connection with M10 screws only permissible up to PN 160. K26 7MF9411-6BB 7MF9411-6BC • for valve manifold, made of stainless steel - for wall mounting or for securing on rack (72 mm grid), weight 0.5 kg Scope of delivery: 1 mounting plate with bolts for mounting on valve manifold - for pipe mounting, weight 0.7 kg Scope of delivery: 1x mounting plate M11, 2x pipe brackets with nuts and washers (for pipe with max. Ø 60.3 mm) Valve manifold 100 bar Suitable for oxygen • for 7MF9411-5A. • for 7MF9411-5B. • for 7MF9411-5C. 1) 2) Siemens FI 01 · 2009 3-spindle and 5-way valve manifold DN 5 • K36: 4 screws 7/16-20 UNF x 1¾ inch to ASME B18.2.1, 2 flat gaskets • K16: 4 screws M10x45 to DIN EN 24014, 4 washers, 2 flat gaskets Flat gaskets made of PTFE, max. 420 bar, 80 °C Note: Flange connection with M10 screws only permissible up to PN 160! Mounting plate M11 7MF9006-6EA M12 7MF9006-6GA M21 7MF9006-6EC Made of electrogalvanized sheet-steel • M11: For wall mounting or for securing on rack (72 mm grid) Scope of delivery: - 1 mounting plate with bolts for mounting on valve manifold • M12: For pipe mounting Scope of delivery: - 1 mounting plate M11 - 2 pipe brackets with nuts and washers for pipes with max. Ø 60.3 mm Valve manifold 100 bar, suitable for oxygen • S12: For 2-way valve manifold • S13: For 3-way valve manifold • S13: For 5-way valve manifold ■ Characteristic curves M22 bar 400 7MF9006-6GC S12 S13 S14 When ordering accessory set or mounting together with the valve manifolds, please use Order code; otherwise use Order No. Flange connections to DIN 19213 only permissible up to 160! 2/202 2-spindle valve manifold DN 5 • K35: 2 screws 7/16-20 UNF x 1¾ inch to ASME B18.2.1, 1 flat gasket • K15: 2 screws M10x45 to DIN EN 24014, 2 washers, 1 flat gasket Washers Ø 10.5 to DIN 125 Mounting plate • for valve manifold, made of electrogalvanized sheet-steel - for wall mounting or for securing on rack (72 mm grid), weight 0.5 kg Scope of delivery: 1 mounting plate with bolts for mounting on valve manifold - for pipe mounting, weight 0.7 kg Scope of delivery: 1x mounting plate M11, 2x pipe brackets with nuts and washers (for pipe with max. Ø 60.3 mm) ■ Accessories Operating pressure Selection and Ordering data 300 200 100 0 0 100 200 300 400 °C Operating temperature Valve manifolds PN 5 (7MF9411-5..), permissible working pressure as a function of the permissible working temperature © Siemens AG 2008 SITRANS P measuring instruments for pressure Fitttings - Shut-off valves for differential pressure transmitters 2-, 3- and 5-spindle valve manifolds DN 5 ■ Dimensional drawings ¼-18 NPT 55 63.5 41.3 ½-14 NPT B C 2 A M10 Ø12 31.75 54 68 182 A Process connection: ½-14 NPT B Transmitter connection: Flange connection to EN 61 518, form B C Vent / test connection: ¼-18 NPT Valve design: external spindle thread Mounting plate 7MF9006-6.. (M11, M12) for valve manifold, dimensions in mm ■ Schematics A A A B B B A C A C 48 2-spindle valve manifold DN 5 (7MF9411-5A.), dimensions in mm 55 41.3 ½-14 NPT 63.5 B A M10 diam. 12 38 54 80 96 210 31.75 B B A Process connection B Transmitter connection C Blow-out-connection 2-spindle, 3-spindle and 5-spindle valve manifold DN 5, connections A Process connection: ½-14 NPT B Transmitter connection: flange connection to EN 61 518, form B Valve design: external spindle thread 3-spindle valve manifold DN 5 (7MF9411-5B.), dimensions in mm A B M10 Ø12 38 54 80 96 142 255 31.75 ½-14 NPT 32.5 43 55 63.5 41.3 C ¼-18 NPT 48 115 A Process connection: ½-14 NPT B Transmitter connection: Flange connection to EN 61 518, form B C Vent / test connection: ¼-18 NPT Valve design: external spindle thread 5-spindle valve manifold DN 5 (7MF9411-5C.), dimensions in mm Siemens FI 01 · 2009 2/203 © Siemens AG 2008 SITRANS P measuring instruments for pressure Fitttings - Shut-off valves for differential pressure transmitters Multiway cocks PN 100 ■ Overview ■ Technical specifications Multiway cocks PN 100 2 Measured medium Water, non-aggressive liquids and gases Aggressive liquids, gases and vapors Material P250GH, mat. No.: 1.0460 X 6 CrNiMoTi 17 12 2, mat. No. 1.4571/316Ti Connections Steel, for pipe Ø 12 mm, L series Stainless steel, for pipe Ø 12 mm, L series • Process connection 2 bulkhead glands • Connection for blow- Pipe union with ferrule ing out Multiway cock PN 100 (7MF9004-1P.) for differential pressure transmitters The multiway cock PN 100 can be flanged to pressure transmitters for differential pressure. ■ Benefits • • • • Version available for aggressive liquids, gases and vapors Robust design Oil-free and grease-free version possible One-hand operation ■ Application The PN 100 multiway cock is available in versions for aggressive and non-aggressive liquids, gases and vapors. ■ Design The multiway cock can be flanged with four screws to pressure transmitters for differential pressure. The PN 100 has 2 process connections and one blow-out connection. A steel version of the multiway cock is available for nonaggressive media, and a stainless steel version for aggressive media. The housing is forged in one piece. The switching lever is removable. Sealing can be improved during operation. Note: An accessory set is always required for flanging of the multiway cock to a differential pressure transmitter. ■ Function • Shutting off the differential pressure lines • Blowing out the differential pressure lines • Testing the pressure transmitter zero Max. permissible working temperature 200 °C Max. permissible working pressure 100 bar (up to max. 60 °C) Weight 2.5 kg Selection and Ordering data Order No. Multiway cock PN 100 for flanging to pressure transmitters, weight 2.5 kg (without accessory set), without certificate 7 MF 9 0 0 4 - 77A for water and non-aggressive gases and vapors 1P for aggressive liquids, gases and vapors 1Q Accessories Factory test certificate EN 10204–2.2 7MF9000-8AB Material acceptance test certificate EN 10204-3.1 7MF9000-8AD Order code Order No. L31 7MF9004-5CC • Standard design L11 7MF9004-6AD • Version for oxygen (together with Order code S11 L15 7MF9004-6AE Selection and Ordering data Further designs1) Please add "-Z" to Order No. and specify Order code. Accessory set to EN (required for flanging, weight 0.2 kg) 4x screws 7/16-20 UNF x 1 inch to ASME B18.2.1; chromized steel 2x gaskets made of PTFE, max. permissible temperature 80 °C Accessory set to DIN (required for flanging, weight 0.2 kg) 4x screws M10x25 to DIN EN 24017; chromized steel 4x washers Ø 10.5 mm to DIN 125; 2x gaskets made of PTFE, max. permissible temperature 80 °C Multiway cock in oil-free and grease-free design Max. PN 63 (instead of PN 100), BAM-tested lubricant, gasket suitable for oxygen measurement (only with Order No. 7MF9004–1Q.Z) Mounting bracket Required for wall mounting or for securing on rack (72 mm grid), made of electrogalvanized sheetsteel, weight 0.85 kg 1) Cock positions; the symbols are printed on the cock 2/204 Siemens FI 01 · 2009 S11 M13 7MF9004-6AA When ordering accessory set or mounting together with the multiway cock, please use Order code; otherwise use Order No. © Siemens AG 2008 SITRANS P measuring instruments for pressure Fitttings - Shut-off valves for differential pressure transmitters Multiway cocks PN 100 ■ Accessories ■ Dimensional drawings Accessory set for multiway cock PN 100 • L31: 4 screws 7/16-20 UNF x 1 inch, 2 flat gaskets • L11: 4 screws M10x25 to DIN EN 24017, 4 washers, 2 flat gaskets • L15 (suitable for oxygen): 4 screws M10x25 to DIN EN 24017, 4 washers, 2 flat gaskets 2 Washers Ø 10.5 to DIN 125 Flat gaskets made of PTFE, max. permissible temperature 80 °C Multiway cock in oil-free and grease-free design • S11 (only for aggressive liquids, gases and vapors (7MF9004-1Q.)): Max. PN 63 (instead of PN 100), BAM-tested lubricant, gasket suitable for oxygen Mounting brackets • M13: Required for wall mounting or for securing on rack (72 mm grid); made of electrogalvanized sheet-steel ■ Characteristic curves Multiway cock 7MF9004-1P. for flanging to pressure transmitters for differential pressure, dimensions in mm 40 6 72 120 90 19 70 Multiway cock PN 100, permissible operating pressure as a function of the permissible operating temperature o11 24 60 Mounting bracket 7MF9004-6AA (M13), dimensions in mm Siemens FI 01 · 2009 2/205 © Siemens AG 2008 SITRANS P measuring instruments for pressure Fitttings - Shut-off valves for differential pressure transmitters 3-way and 5-way valve manifolds DN 5 ■ Overview ■ Function • Shutting off the differential pressure lines • Checking the pressure transmitter zero • In addition, the five-way valve manifold permits blowing out of the differential pressure lines. 2 The three-spindle and five-spindle valve manifolds DN 5 (7MF9410-1../-3..) are used to shut off the differential pressure lines and to check the transmitter zero. In addition, the five-way valve manifold permits blowing out of the differential pressure lines. ■ Benefits • Available for aggressive and non-aggressive liquids and gases • Max. working pressure 420 bar, with version for oxygen max. 100 bar ■ Application The 3-way and 5-way valve manifolds are available in versions for aggressive and non-aggressive liquids and gases. Mounting plates are available for wall mounting, for securing to mounting racks or for pipe mounting. ■ Design The process connection of the 3-way and 5-way valve manifolds is a pipe union with ferrule. Both valve manifolds have 2 flange connections for connecting a pressure transmitter. In addition, the five-way valve manifold has 2 blow-out connections. Depending on the version the valve manifold has either 3 or 5 valves, each with an internal spindle thread. Materials used For non-aggressive liquids and gases For aggressive liquids and gases Component Material Mat. No. Material Housing P250GH 1.0460 Head parts C 35 1.0501 Spindles X 12 CrMoS 17 1.4104 Cones X 35 CrMo 17 hardened and tempered 1.4122 Valve seats X 6 CrNiMoTi 17 12 2 1.4571/ 316Ti Packings PTFE - 2/206 Siemens FI 01 · 2009 Mat. No. X6 1.4571/ CrNiMoTi 316Ti 17 12 2 PTFE - Selection and Ordering data Order No. 3-way valve manifold DN 5 for flanging to pressure transmitters for differential pressure, process connection: Pipe union with ferrule, max. working pressure 420 bar, weight 2.9 kg (order accessory set and mounting plate with Order code), without certificate 7 MF 9 4 1 0 - 77A • for non-aggressive liquids and gases 1E • for aggressive liquids and gases 1F 5-way valve manifold DN 5 for flanging to pressure transmitters for differential pressure, process connection: Pipe union with ferrule, max. working pressure 420 bar, weight 4.4 kg (order accessory set and mounting plate with Order code), without certificate • for non-aggressive liquids and gases 3E • for aggressive liquids and gases 3F Accessories Factory test certificate EN 10204–2.2 7MF9000-8AB Material acceptance test certificate EN 10204-3.1 7MF9000-8AD © Siemens AG 2008 SITRANS P measuring instruments for pressure Fitttings - Shut-off valves for differential pressure transmitters 3-way and 5-way valve manifolds DN 5 Selection and Ordering data Order code Order No. Further designs1) Please add "-Z" to Order No. and specify Order code. Accessory set to EN (required for flanging, weight 0.2 kg) 7/ 4x screws 16-20 UNF x 21/8 inch to ASME B18.2; chromized steel 2x flat gaskets made of PTFE, max. permissible 420 bar, 80 °C B31 F) 7MF9010-5CC 4x screws 7/16-20 UNF x 21/8 inch to ASME B18.2; chromized steel 2x O-rings to DIN 3771, 20 x 2.65 - S - FPM90, max. permissble 420 bar, 120 °C B34 7MF9410-5CA Flat gaskets made of PTFE, max. 420 bar, 80 °C O-ring to DIN 3771, 20 x 2.65 – S – FPM90, max. 420 bar, 120 °C Note: M10 screws only permissible up to PN 160! 4x screws M10x55 to DIN EN 24014; chromized steel 4x washers Ø 10.5 mm to DIN 125; 2x flat gaskets made of PTFE, max. permissible 420 bar, 80 °C Mounting plate • Standard design B11 7MF9010-6AD • Version for oxygen B15 7MF9010-6AE 4x screws M10x55 to DIN EN 24014; chromized steel 4x washers Ø 10.5 mm to DIN 125; 2x O-rings to DIN 3771, 20 x 2.65 - S - FPM90, max. permissble 420 bar, 120 °C B16 7MF9010-6CC for pipe mounting, weight 0.7 kg Scope of delivery: 1x mounting plate M11, 2x pipe brackets with nuts and washers (for pipe with max. Ø 60.3 mm) Accessory set for 3-way and 5-way valve manifold DN 5 for flanging • B31: 4 screws 7/16-20 UNF x 21/8 inch to ASME B18.2.1, 2 flat gaskets • B34: 4 screws 7/16-20 UNF x 21/8 inch to ASME B18.2.1, 2 O-rings (FPM 90) • B11: 4 screws M10x55 to DIN EN 24014, 4 washers, 2 flat gaskets • B15 (suitable for oxygen): 4 screws M10x55 to DIN EN 24014, 4 washers, 2 flat gaskets • B16: 4 screws M10x55 to DIN EN 24014, 4 washers, 2 O-rings (FPM 90) Washers Ø 10.5 to DIN 125 Accessory set to DIN2) (required for flanging, weight 0.2 kg) Mounting plate for valve manifold, made of electrogalvanized sheet-steel for wall mounting or for securing on rack (72 mm grid), weight 0.5 kg Scope of delivery: 1 mounting plate with bolts for mounting on valve manifold ■ Accessories Made of electrogalvanized sheet-steel • M11: For wall mounting or for securing on rack (72 mm grid) Scope of delivery: - 1 mounting plate 7MF9006-6EA with bolts for mounting on valve manifold • M12: For pipe mounting Scope of delivery: - 1 mounting plate M11 - 2 pipe brackets with nuts and washers for pipes with max. Ø 60.3 mm Valve manifold 100 bar, suitable for oxygen M11 7MF9006-6EA M12 7MF9006-6GA S12: Only in combination with versions for aggressive liquids and gases Valve manifold 100 bar suitable for oxygen for 7MF9410-1F S13 for 7MF9410-3F S14 1) 2) When ordering accessory set or mounting together with the valve manifolds, please use Order code; otherwise use Order No. Flange connections to DIN 19213 only permissible up to PN 160! F) Subject to export regulations AL: 9I999, ECCN: N. Siemens FI 01 · 2009 2/207 2 © Siemens AG 2008 SITRANS P measuring instruments for pressure Fitttings - Shut-off valves for differential pressure transmitters 3-way and 5-way valve manifolds DN 5 ■ Characteristic curves 300 200 100 0 0 100 200 300 400 °C Operating temperature Permissible operating pressure as a function of the permissible operating temperature Mounting plate 7MF9006-6.. (M11, M12) for valve manifold, dimensions in mm ■ Dimensional drawings 7 51 Ø 12 A 54 72 108 147 ■ Schematics 2,4 A A A Process connection B Transmitter connection C Vent/test connection 70 41,3 41 22 8 Process connection (e.g. on primary device): Pipe union with ferrule, diameter 12 mm, S series to DIN 2353 B Transmitter connection: Flange connection to EN 61 518, form A Valve design: internal spindle thread 3-way valve manifold DN 5 (7MF9410-1..), dimensions in mm 5-way valve manifold DN 5 (7MF9410-3..), dimensions in mm Siemens FI 01 · 2009 A 38 M10 A 2/208 A B 25 2 Operating pressure bar 400 B B Three-way valve manifold for liquids and gases C B B C Five-way valve manifold for liquids and gases or vapors 3-way and 5-way valve manifolds, connections © Siemens AG 2008 SITRANS P measuring instruments for pressure Fitttings - Shut-off valves for differential pressure transmitters 3-way valve manifold DN 8 ■ Overview ■ Function The 3-way valve manifold DN 8 performs two functions as standard: • Shutting off the differential pressure lines • Checking the pressure transmitter zero All versions are also available with a test connection, to which a test device for checking the pressure transmitter characteristic can be connected. Selection and Ordering data Order No. 3-way valve manifold DN 8 for flanging to pressure transmitters for differential pressure, max. working pressure 420 bar, (order accessory set and mounting plate with Order code), without certificate 7 MF 9 4 1 6 - 77A for non-aggressive liquids and gases procedss connection: Pipe union with ferrule The 3-way valve manifold DN 8 (7MF9416-1../-2..) is for pressure transmitters for differential pressure. It is used to shut off and blow out differential pressure lines and to test the pressure transmitter zero. In the designs with a test connection, a test device can be connected to test the pressure transmitter characteristic. ■ Benefits • For aggressive and non-aggressive liquids and gases • The maximum working pressure is 420 bar. ■ Application The 3-way valve manifold is available in versions for aggressive and non-aggressive liquids and gases. • without test connection 1B • with test connection 1C for non-aggressive liquids and gases procedss connection: Welding pin Ø 14 x 2.5 • without test connection 2C • with test connection 2D for aggressive liquids and gases process connection: Pipe union with ferrule • without test connection 1D • with test connection 1E Accessories Factory test certificate EN 10204–2.2 7MF9000-8AB Material acceptance test certificate EN 10204-3.1 7MF9000-8AD Mounting plates are available for wall mounting, for securing to mounting racks or for pipe mounting. ■ Design For the process connection on the version for non-aggressive media it is possible to choose between a pipe union with ferrule and welding pins. The version for aggressive media always has a pipe union with ferrule. Both versions are available optionally with a test connection M20x1.5. The valves have an internal spindle thread. Materials used For non-aggressive liquids and gases For aggressive liquids and gases Component Material Mat. No. Material X6 1.4571/ CrNiMoTi 316Ti 17 12 2 Housing P250GH 1.0460 Head parts C 35 1.0501 Spindles X 12 CrMoS 17 1.4104 Cones X 35 CrMo 17 hardened and tempered 1.4122 Valve seats X 6 CrNiMoTi 17 12 2 1.4571/316Ti Packings - PTFE PTFE Mat. No. - Siemens FI 01 · 2009 2/209 2 © Siemens AG 2008 SITRANS P measuring instruments for pressure Fitttings - Shut-off valves for differential pressure transmitters 3-way valve manifold DN 8 Order code Order No. Further designs1) Please add "-Z" to Order No. and specify Order code. 2 Accessory set to EN (required for flanging, weight 0.2 kg) 4x screws 7/16-20 UNF x 21/8 inch to ASME B18.2; chromized steel 2x flat gaskets made of PTFE, max. permissible 420 bar, 80 °C B31 F) 7MF9010-5CC 4x screws 7/16-20 UNF x 21/8 inch to ASME B18.2; chromized steel 2x O-rings to DIN 3771, 20 x 2.65 - S - FPM90, max. permissble 420 bar, 120 °C B34 7MF9410-5CA Note: M10 screws only permissible up to PN 160! Mounting plate B11 7MF9010-6AD 4x screws M10x55 to DIN EN 24014; chromized steel 4x washers Ø 10.5 mm to DIN 125; 2x O-rings to DIN 3771, 20 x 2.65 - S - FPM90, max. permissble 420 bar, 120 °C B16 7MF9010-6CC for wall mounting or for securing on rack (72 mm grid), weight 0.5 kg Scope of delivery: 1 mounting plate with bolts for mounting on valve manifold M11 for pipe mounting, weight 0.7 kg Scope of delivery: 1x mounting plate M11, 2x pipe brackets with nuts and washers (for pipe with max. Ø 60.3 mm) M12 F) Subject to export regulations AL: 9I999, ECCN: N. bar 400 7MF9006-6EA 7MF9006-6GA When ordering accessory set or mounting together with the valve manifold, please use Order code; otherwise use Order No. Flange connections to DIN 19213 only permissible up to PN 160! Siemens FI 01 · 2009 Made of electrogalvanized sheet-steel • M11: For wall mounting or for securing on rack (72 mm grid) Scope of delivery: - 1 mounting plate with bolts for mounting on valve manifold • M12: For pipe mounting Scope of delivery: - 1 mounting plate M11 - 2 pipe brackets with nuts and washers for pipes with max. Ø 60.3 mm ■ Characteristic curves Mounting plate for valve manifold, made of electrogalvanized sheet-steel 2/210 Washers Ø 10.5 to DIN 125 O-ring to DIN 3771, 20 x 2.65 – S – FPM90, max. 420 bar, 120 °C 4x screws M10x55 to DIN EN 24014; chromized steel 4x washers Ø 10.5 mm to DIN 125; 2x flat gaskets made of PTFE, max. permissible 420 bar, 80 °C 2) Accessory set for 3-way valve manifold DN 8 for flanging • B31: 4 screws 7/16-20 UNF x 21/8 inch to ASME B18.2.1, 2 flat gaskets • B34: 4 screws 7/16-20 UNF x 21/8 inch to ASME B18.2.1, 2 O-rings (FPM 90) • B11: 4 screws M10x55 to DIN EN 24014, 4 washers, 2 flat gaskets • B16: 4 screws M10x55 to DIN EN 24014, 4 washers, 2 O-rings (FPM 90) Flat gaskets made of PTFE, max. 420 bar, 80 °C Accessory set to DIN2) (required for flanging, weight 0.2 kg) 1) ■ Accessories Operating pressure Selection and Ordering data 300 200 100 0 0 100 200 300 400 °C Operating temperature 3-way valve manifold DN 8, permissible working pressure as a function of the permissible working temperature © Siemens AG 2008 SITRANS P measuring instruments for pressure Fitttings - Shut-off valves for differential pressure transmitters 3-way valve manifold DN 8 ■ Dimensional drawings ■ Schematics 48 A C Ø12 D 2 D B 41,3 A 38 25 A 31,5 48 7 B B Three-way valve manifold for liquids and gases 8 M10 A Process connection B Transmitter connection C Vent/test connection 54 72 108 147 160 195 22 3-way valve manifold DN 8, connections 41 A Process connection (e.g. on primary device): Pipe union with ferrule, diameter 12 mm, S series to DIN 2353 Transmitter connection: Flange connection to EN 61 518, form A C Test connection: M20x1.5 Valve design: internal spindle thread B C 31,5 o12 54 72 108 147 160 195 B 41,3 A 38 50 M10 8 25 48 7 48 3-way valve manifold DN 8 (7MF9416-1..) with pipe union, dimensions in mm 22 41 A Process connection (e.g. on primary device): Welding pin, diameter 14x2,5 B Transmitter connection: Flange connection to EN 61 518, form A C Test connection: M20x1.5 Valve design: internal spindle thread 3-way valve manifold DN 8 (7MF9416-2..) with welding pin, dimensions in mm Mounting plate 7MF9006-6.. (M11, M12) for valve manifold, dimensions in mm Siemens FI 01 · 2009 2/211 © Siemens AG 2008 SITRANS P measuring instruments for pressure Fitttings - Shut-off valves for differential pressure transmitters Valve manifold combination DN 5/DN 8 ■ Overview ■ Function • Shutting off the differential pressure lines • Blowing out the differential pressure lines • Checking the pressure transmitter zero 2 As an option it is possible to order a version with a test connection, to which a test device for checking the transmitter characteristic can be connected. Selection and Ordering data Order No. Valve manifold combination DN 5/DN 8 for vapors 7MF 9 4 1 6 - 6 7A for flanging to pressure transmitters for differential pressure, max. working pressure 420 bar, also available in stainless steel on request (order accessory set with Order code), without certificate • without test connection C The valve manifold combination DN 5/DN 8 (7MF9416-6..) is for pressure transmitters for differential pressure. • with test connection M20 × 1.5 D The combination is used to shut off and blow out differential pressure lines and to test the pressure transmitter zero. Factory test certificate EN 10204–2.2 7MF9000-8AB Material acceptance test certificate EN 10204-3.1 7MF9000-8AD In the designs with a test connection, a test device can be connected to test the pressure transmitter characteristic. ■ Benefits Selection and Ordering data The valve manifold combination DN 5/DN 8 is designed for vapors. ■ Design The valve manifold combination DN 5/DN 8 has a process connection with welding pins. The connection for the pressure transmitter is designed as as flange connection, while the blow-out connection is designed as a pipe union with ferrule. The manifold valves have an internal spindle thread, while the blow-out valves have an external spindle thread. The optional test connections are M20x1.5. Materials used Valve manifold DN 5 Blow-out valves DN 8 Component Material Mat. No. Material Mat. No. Housing P250GH 1.0460 16 Mo 3 1.5415 Head parts C 35 1.0501 21 CrMo V57 1.7709 Spindles X 12 CrMoS 17 1.4104 X 20 Cr 13 1.4021 Cones X 35 CrMo 17 1.4122 X 35 CrMo 17 hardened and tempered 1.4122 Valve seats X 6 CrNiMoTi 1.4571/316Ti X 20 Cr 13 1.4021 Packings PTFE - Pure graphite - - 16 Mo 3 1.5415 Siemens FI 01 · 2009 Order No. B34 7MF9410-5CA B16 7MF9010-6CC Please add "-Z" to Order No. and specify Order code. ■ Application Welding pins - Order code Further designs1) • Max. working pressure 420 bar 2/212 Accessories Accessory set to EN (required for flanging, weight 0.2 kg) 4x screws 7/16-20 UNF x 21/8 inch to ASME B18.2; chromized steel 2x O-rings to DIN 3771, 20 x 2.65 - S - FPM90, max. permissble 420 bar, 120 °C Accessory set to DIN2) (required for flanging, weight 0.2 kg) 4x screws M10x55 to DIN EN 24014; chromized steel 4x washers Ø 10.5 mm to DIN 125; 2x O-rings to DIN 3771, 20 x 2.65 - S - FPM90, max. permissble 420 bar, 120 °C Flange connection to DIN 19213 only permissible up to PN 160! 1) 2) When ordering accessory set together with the valve manifold combination, please use Order code; otherwise use Order No. Flange connections to DIN 19213 only permissible up to 160! © Siemens AG 2008 SITRANS P measuring instruments for pressure Fitttings - Shut-off valves for differential pressure transmitters Valve manifold combination DN 5/DN 8 ■ Accessories ■ Dimensional drawings Accessory set for valve manifold combination DN 5/DN 8 for flanging • B34: 4 screws 7/16-20 UNF x 21/8 inch to ASME B18.2.1, 2 O-rings (FPM 90) • B16: 4 screws M10x55 to DIN EN 24014, 4 washers, 2 O-rings (FPM 90) 2 Washers Ø 10.5 to DIN 125 O-ring to DIN 3771, 20 x 2.65 - S – FPM90, max. 420 bar, 120 °C Note: M10 screws only permissible up to PN 160! ■ Characteristic curves Operating pressure bar 400 1 Valve manifold 2 Blow-out connection 300 200 100 0 1) 1 2 0 100 200 300 400 500 °C Operating temperature 1) According to DIN 19210 the design can be such that the temperatures for the differential pressure line can be set approx. 100 °C lower than the media temperature. Permissible operating pressure as a function of the permissible operating temperature Valve manifold combination DN 5/DN 8 (7MF9416-6C.), dimensions in mm (deviating dimensions for 7MF9416-6D. shown in brackets) ■ Schematics A A D D Valve manifold combination for vapors C B B C A B C D Process connection Transmitter connection Blow-out connection Test connection Valve manifold combination DN 5/DN 8, connections Siemens FI 01 · 2009 2/213 © Siemens AG 2008 SITRANS P measuring instruments for pressure Fitttings - Shut-off valves for differential pressure transmitters Valve manifold combination DN 8 ■ Overview ■ Function • Shutting off the differential pressure lines • Blowing out the differential pressure lines • Checking the pressure transmitter zero 2 As an option it is possible to order a version with a test connection, to which a test device for checking the pressure transmitter characteristic can be connected. The valve manifold combination DN 8 (7MF9416-4..) is for pressure transmitters for differential pressure. It is used to shut off and blow out the differential pressure lines and to check the pressure transmitter zero. In the designs with a test connection, a test device can be connected to check the pressure transmitter characteristic. ■ Benefits • Max. working pressure 420 bar ■ Application The valve manifold combination DN 8 is designed for vapors. ■ Design The valve manifold combination DN 8 has a process connection with welding pins. The connection for the pressure transmitter is designed as as flange connection, while the blow-out connection is designed as a pipe union with ferrule. The manifold valves have an internal spindle thread, while the blow-out valves have an external spindle thread. The optional test connection is M20x1.5. The valve manifold combination DN 8 is supplied with a mounting plate. Materials used Valve manifold Blow-out valves Component Material Mat. No. Material Mat. No. Housing P250GH 1.0460 16 Mo 3 1.5415 Head parts C 35 1.0501 21 CrMo V57 1.7709 Spindles X 12 CrMoS 17 1.4104 X 20 Cr 13 1.4021 Cones X 35 CrMo 17 1.4122 X 35 CrMo 17 hardened and tempered 1.4122 Valve seats X 6 CrNiMoTi 1.4571/316Ti X 20 Cr 13 1.4021 Packings PTFE Welding pins - 2/214 - Pure graphite - - 16 Mo 3 1.5415 Siemens FI 01 · 2009 © Siemens AG 2008 SITRANS P measuring instruments for pressure Fitttings - Shut-off valves for differential pressure transmitters Valve manifold combination DN 8 Selection and Ordering data Order No. Valve manifold combination DN 8 for vapors for flanging to pressure transmitters for differential pressure, with mounting plate, max. working pressure 420 bar, also available in stainless steel on request (order accessory set with Order code), without certificate 7 MF 9 4 1 6 - 77A ■ Characteristic curves • without test connection 4C • with test connection M20 × 1.5 4D Operating pressure bar 400 7MF9000-8AB Material acceptance test certificate EN 10204-3.1 7MF9000-8AD 200 Order code Order No. Further designs1) 0 100 200 300 400 500 °C Operating temperature Permissible operating pressure as a function of the permissible operating temperature ■ Dimensional drawings Please add "-Z" to Order No. and specify Order code. 7MF9410-5CA 7 54 72 7MF9010-6CC 195 O-ring to DIN 3771, 20 x 2.65 – S – FPM90, max. 420 bar, 120 °C diam. 12 ca. 119 diam. 14x2.5 7 72 ■ Accessories Washers Ø 10.5 to DIN 125 38 26 195 When ordering accessory set together with the valve manifold combination, please use Order code; otherwise use Order No. Flange connections to DIN 19213 only permissible up to 160! Accessory set for valve manifold combination DN 8 for flanging • B34: 4 screws 7/16-20 UNF x 21/8 inch to ASME B 18.2.1, 2 O-rings (FPM 90) • B16: 4 screws M10x55 to DIN EN 24014, 4 washers, 2 O-rings (FPM 90) 38 351 B16 B 41.3 17 2) D 109 B34 5,5 1) 2.5 A M20x1.5 Accessory set to DIN2) (required for flanging, weight 0.2 kg) 4x screws M10x55 to DIN EN 24014; chromized steel 4x washers Ø 10.5 mm to DIN 125; 2x O-rings to DIN 3771, 20 x 2.65 - S - FPM90, max. permissble 420 bar, 120 °C Flange connection to DIN 19 213 only permissible up to PN 160! 11 72 4x screws /16-20 UNF x 21/8 inch to ASME B18.2; chromized steel 2x O-rings to DIN 3771, 20 x 2.65 - S - FPM90, max. permissble 420 bar, 120 °C diam. 14 160 155 A Accessory set to EN (required for flanging, weight 0.2 kg) 7 2 1 100 0 1) According to DIN 19210 the design can be such that the temperatures for the differential pressure line can be set approx. 100 °C lower than the media temperature. 1) 525 Selection and Ordering data 2 300 Accessories Factory test certificate EN 10204–2.2 1 Valve manifold 2 Blow-out connection C 11 C 155 ca. 110 A Process connection (e.g. on primary device): Welding pin Transmitter connection: Flange connection to EN 61 518, form A C Blow-out connection: Pipe union with ferrule, diameter 14 mm, S series to DIN 2353 C Test connection (only with Order No. 7MF9416-4D.): M20x1.5 Valve design: Manifold valves: internal spindle thread Blow-out valves: external spindle thread B Note: M10 screws only permissible up to PN 160! Valve manifold combination DN 8 (7MF9416-4..), dimensions in mm ■ Schematics A A D D Valve manifold combination for vapors C B B C A B C D Process connection Transmitter connection Blow-out connection Test connection Valve manifold combination DN 8, connections Siemens FI 01 · 2009 2/215 © Siemens AG 2008 SITRANS P measuring instruments for pressure Fitttings - Shut-off valves for differential pressure transmitters 2-, 3- and 5-spindle valve manifolds for installing in protective boxes ■ Overview 2 Selection and Ordering data Order No. Valve manifolds DN 5 for mounting in protective boxes for liquids and gases for flanging to pressure transmitters for absolute and differential pressure Material: stainless steel, mat. No: 1.4404/316L max. working pressure 420 bar (order accessory set with Order code), without certificate 7 MF 9 4 1 2 - 77A • 2-spindle valve manifold with rotatng sleeve G½ 1B • 2-spindle valve manifold with flange connection 1C • 3-spindle valve manifold 1D • 5-spindle valve manifold 1E Accessories The two-spindle, three-spindle and five-spindle valve manifolds (7MF9412-1..) are used to shut off the differential pressure lines and to check the transmitter zero. The five-spindle valve manifold permits venting on the transmitter side and checking of the transmitter characteristic. These valve manifolds are preferentially used when mounting in protective boxes. In addition, they can also be used for wall, frame or pipe mounting together with the mounting bracket. Transmitters of the DS series can be operated and read from the front when using these valve manifolds. ■ Application The valve manifolds DN 5 are designed for liquids and vapors and for installing in protective boxes. Each is available in a version for oxygen on request ■ Design Factory test certificate EN 10204–2.2 7MF9000-8AB Material acceptance test certificate EN 10204-3.1 7MF9000-8AD Order code Order No. 2x screws 7/16-20 UNF x 2 inch to ASME B18.2.1; chromized steel 1x O-ring to DIN 3771, 20 x 2.65 - S - FPM90, max. permissble 420 bar, 120 °C F32 7MF9412-6CA 2x screws 7/16-20 UNF x 2 inch to ASME B18.2.1; chromized steel 1x gasket made of PTFE, max. permissible 420 bar, 80 °C2) F35 7MF9412-6DA Selection and Ordering data Further designs1) Please add "-Z" to Order No. and specify Order code. Accessory set to EN (connection between valve manifold and pressure transmitter) for valve manifold 7MF9412–1C. All versions of the spindle manifolds have a process connection ½-14 NPT. for valve manifold 7MF9412–1D and -1E. The connection for the pressure transmitter is always designed as a flange connection to EN 61518, Form A. 4x screws 7/16-20 UNF x 2 inch to ASME B18.2.1; chromized steel 2x O-rings to DIN 3771, 20 x 2.65 - S - FPM90, max. permissble 420 bar, 120 °C2) F34 7MF9412-6GA 4x screws 7/16-20 UNF x 2 inch to ASME B18.2.1; chromized steel 2x flat gaskets made of PTFE, max. permissible 420 bar, 80 °C2) F36 7MF9412-6HA The 2-spindle and the 5-spindle valve manifold have in addition a vent and test connection ¼-18 NPT. The valves have an external spindle thread. Materials used Components Material Mat. No. Housing X 2 CrNiMo 17 13 2 1.4404/316L Cones X 6 CrNiMoTi 17 12 2 1.4571/316Ti Spindles X 2 CrNiMo 18 10 1.4404/316L Head parts X 5 CrNiMo 18 10 1.4401/316 Packings PTFE - ■ Functions Functions of all valve manifolds: • Shutting off the differential pressure lines • Checking the pressure transmitter zero Additional functions of the 2-spindle and 5-spindle valve manifolds through the vent and test connection: • Venting on the transmitter side • Checking the pressure transmitter characteristic 2/216 Siemens FI 01 · 2009 © Siemens AG 2008 SITRANS P measuring instruments for pressure Fitttings - Shut-off valves for differential pressure transmitters 2-, 3- and 5-spindle valve manifolds for installing in protective boxes Order code Order No. Further designs1) Accessory set for 2-, 3- and 5-spindle valve manifolds (Connection between manifold and transmitter) Please add "-Z" to Order No. and specify Order code. Accessory set to DIN (connection between valve manifold and pressure transmitter) for valve manifold 7MF9412–1C. 2x screws M10x50 to DIN EN 24014; chromized steel 2x washers Ø 10.5 mm to DIN 125; 1x O-ring to DIN 3771, 20 x 2.65 - S - FPM90, max. permissble 420 bar, 120 °C2) F12 7MF9412-6AA 2x screws M10x50 to DIN EN 24014; chromized steel 2x washers Ø 10.5 mm to DIN 125; 1x gasket made of PTFE, max. permissible 420 bar, 80 °C2) for valve manifold 7MF9412–1D and -1E. F15 7MF9412-6BA 4x screws M10x50 to DIN EN 24014; chromized steel 4x washers Ø 10.5 mm to DIN 125; 2x O-rings to DIN 3771, 20 x 2.65 - S - FPM90, max. permissble 420 bar, 120 °C2) F14 7MF9412-6EA 4x screws M10x50 to DIN EN 24014; chromized steel 4x washers Ø 10.5 mm to DIN 125; 2x flat gaskets made of PTFE, max. permissible 420 bar, 80 °C2) F16 7MF9412-6FA Flat-gaskets made of PTFE, max. 420 bar, 80 °C Note: Flange connections with M10 screws only permissible up to PN 160! Mounting bracket for wall mounting or for securing to mounting rack M14 7MF9006-6LA • for valve manifold 7MF9412-1D. M17 7MF9006-6NA • for valve manifold 7MF9412-1E. M18 7MF9006-6PA M16 7MF9006-6KA Mounting clip Valve manifold 100 bar suitable for oxygen • for valve manifolds 7MF9412-1B. and -1C. S12 • for valve manifold 7MF9412-1D. S13 • for valve manifold 7MF9412-1E. S14 2) 3-spindle and 5-way valve manifold DN 5 • F34: 4 screws 7/16 20 UNF x 2 inch toASME B 18.2.1, 2 O-rings (FPM90) • F36: 4 screws 7/16 20 UNF x 2 inch toASME B 18.2.1, 2 flat-gaskets • F14: 4 screws M10x50 toDIN EN 24014, 4 washers, 2 O-rings (FPM90) • F16: 4 screws M10x50 toDIN EN 24014, 4 washers, 2 flat-gaskets O-ring to DIN 3771, 20 x 2,65 - S - FPM90; max.420 bar, 120 °C • for valve manifolds 7MF9412-1B. and -1C. 1) 2-spindle valve manifold DN 5 with flange connection • F32: 2 screws 7/16 20 UNF x 2 inch to ASME B 18.2.1, 1 O Ring (FPM90) • F35: 2 screws 7/16 20 UNF x 2 inch to ASME B 18.2.1, 1 flat-gasket • F12: 2 screws M10x50 to DIN EN 24014, 2 washers, 1 O-ring (FPM90) • F15: 2 screws M10x50 toDIN EN 24014, 2 washers, 1 flat gasket Washers Ø 10,5 to DIN 125 Mounting bracket required for wall mounting or for securing to mounting rack, with bolts for mounting on valve manifold 2 off, to secure mounting bracket to pipe ■ Accessories When ordering accessory set or mounting together with the valve manifolds, please use Order code; otherwise use Order No. Flange connections with M10 screws only permissible up to PN 160! With bolds for mounting on valve manifold • M14: For 2-spindle valve manifold DN 5 • M17: For 3-spindle valve manifold DN 5 • M18: For 5-spindle valve manifold DN 5 Mounting clips (2 off) • M16: For securing the mounting brackets M14, M17 and M18 to pipe Valve manifold 100 bar, suitable for oxygen • S12: For 2-spindle valve manifold DN 5 • S13: For 3-spindle valve manifold DN 5 • S14: For 5-spindle valve manifold DN 5 ■ Characteristic curves bar 400 Operating pressure Selection and Ordering data 300 420 bar at 120 °C 350 bar at 200 °C 200 100 0 0 100 200 300 400 °C Operating temperature Permissible operating pressure as a function of the permissible operating temperature Siemens FI 01 · 2009 2/217 2 © Siemens AG 2008 SITRANS P measuring instruments for pressure Fitttings - Shut-off valves for differential pressure transmitters 2-, 3- and 5-spindle valve manifolds for installing in protective boxes ■ Dimensional drawings 12 54 G½ 37 2 115 41.3 B 80 63.5 M8 103 ½NPT 80 A M8 ¼-18 NPT C A 10 M8 ½-14 NPT 38 88.9 M8 A Process connection: ½-14 NPT B Transmitter connection: Flange connection EN 61 518, form A Valve design: external spindle thread 38 C A B 10 38 B 3-spindle valve manifold DN 5 (7MF9412-1D..), dimensions in mm Process connection: ½-14 NPT Transmitter connection: Nipple to DIN 16 284, G½, SW 27 Vent / test connection: ¼-18 NPT Ø 12 15 41.3 12 115 70 approx. 157 54 2-spindle valve manifold DN 5 (7MF9412-1B..) with rotating sleeve, dimensions in mm M8 10 C 41.3 ¼-18 NPT B C A M8 10 38 80 115 A ¼-18 NPT ½-14 NPT M8 A B Process connection: ½-14 NPT Transmitter connection: Flange connection to EN 61 518, form A C Vent / test connection: ¼-18 NPT Valve design: external spindle thread 2-spindle valve manifold DN 5 (7MF9412-1C..), dimensions in mm 2/218 Siemens FI 01 · 2009 ½-14 NPT B M8 38 87 114 ca. 228 A B Process connection: ½-14 NPT Transmitter connection: Flange connection to EN 61 518, form A C Vent / test conenction: ¼-18 NPT Valve design: external spindle thread 5-spindle valve manifold DN 5 (7MF9412-1E..), dimensions in mm © Siemens AG 2008 SITRANS P measuring instruments for pressure Fitttings - Shut-off valves for differential pressure transmitters 12 2-, 3- and 5-spindle valve manifolds for installing in protective boxes 72 100 2.5 72 55 4x Ø11 R5 2 8 72 8 0 R2 72 M8 12 +1 R5 R10 R2.5 60,3 100 155 17 9 R 19 Ø9 26.6 31.6 57.6 77.1 38 76 31.5 Ø16 Ø26 24 6.5 26 4.5 19 180 180 110 6.35 Mounting bracket (7MF9006-6PA)/(M18) for 5-spindle valve manifolds, dimensions in mm 110 Mounting bracket (7MF9006-6LA)/(M14) for 2-spindle valve manifolds, dimensions in mm ■ Schematics B A Process connection B Connection for pressure gauge or transmitter for pressure or absolute pressure C Vent/test connection C 72 A 8 2-spindle valve manifold DN 5 (with rotating sleeve G½ or flange connection), connections 72 60,3 110 A A 180 A Process connection B Transmitter connection B B 3-spindle valve manifold DN 5, connections 19 26 38 76 C A A C A Process connection B Transmitter connection C Vent/test connection Mounting bracket (7MF9006-6NA)/(M17) for 3-spindle valve manifolds, dimensions in mm B B 5-spindle valve manifold DN 5, connections Siemens FI 01 · 2009 2/219 © Siemens AG 2008 SITRANS P measuring instruments for pressure Fitttings - Shut-off valves for differential pressure transmitters 3- and 5-spindle valve manifolds for vertical angular differential pressure lines ■ Overview 2 Selection and Ordering data Order No. Valve manifolds for vertical differential pressure lines for liquids and gases for flanging to pressure transmitters for absolute and differential pressure Material: stainless steel, mat. No: 1.4404/316L max. working pressure 420 bar (order accessory set with Order code), without certificate 7 MF 9 4 1 3 - 77A • 3-spindle valve manifold 1D • 5-spindle valve manifold 1E Accessories Factory test certificate EN 10204–2.2 7MF9000-8AB Material acceptance test certificate EN 10204-3.1 7MF9000-8AD Order code Order No. K36 7MF9411-5DB K16 7MF9411-6BB • for valve manifold 7MF9413-1D. M17 7MF9006-6NA • for valve manifold 7MF9413-1E. M18 7MF9006-6PA M19 7MF9006-6QA M16 7MF9006-6KA Selection and Ordering data Further designs1) These 3-spindle and 5-spindle valve manifolds 7MF9413-1.. were developed specially for vertical differential pressure lines. Please add "-Z" to Order No. and specify Order code. The valve manifolds are used to shut off the differential pressure lines and to check the pressure transmitter zero. Accessory set to EN (connection between valve manifold and pressure transmitter) The 5-spindle valve manifold permits venting on the transmitter side and checking of the pressure transmitter characteristic. 4x screws 7/16-20 UNF x 1¾ inch to ASME B18.2.1; chromized steel 2x flat gaskets made of PTFE, max. permissible 420 bar, 80 °C ■ Benefits • For vertical differential pressure lines • Max. operating pressure 420 bar • Transmitters of the DS series can be operated and read from the front. ■ Application The 3-spindle and 5-spindle valve manifolds for vertical differential pressure lines are for liquids and gases. The valve manifolds are flanged on the pressure transmitter. ■ Design All versions of the spindle valve manifolds have a process connection ½-14 NPT. The connection for the pressure transmitter is always designed as a flange connection to EN 61518, form B . The 2-spindle and the 5-spindle valve manifold have in addition a vent and test connection ¼-18 NPT. Accessory set to DIN2) (connection between valve manifold and pressure transmitter) 4x screws M10x45 to DIN EN 24014; chromized steel 4x washers Ø 10.5 mm to DIN 125; 2x flat gaskets made of PTFE, max. permissible 420 bar, 80 °C Flange connection with M10 screws only permissible up to PN 160. Mounting bracket required for wall mounting or for securing to mounting rack, with bolts for mounting on valve manifold required for mounting on 2" standpipe, with bolts for mounting on valve manifold • for valve manifold 7MF9413-1D. Materials used: Mounting clip Component Material Mat. No. Housing X 2 CrNiMo 17 13 2 1.4404/316L Cones X 6 CrNiMoTi 17 12 2 1.4571/316Ti Spindles X 2 CrNiMo 18 10 1.4404/316L Valve manifold 100 bar suitable for oxygen 2 off, to secure mounting bracket to pipe Head parts X 5 CrNiMo 18 10 1.4401/316 • for valve manifold 7MF9413-1D. S13 Packings PTFE - • for valve manifold 7MF9413-1E. S14 ■ Function 1) 2) Functions of all valve manifolds: • Shutting off the differential pressure lines • Checking the pressure transmitter zero Additional functions of the 2-spindle and 5-spindle valve manifolds through the vent and test connection: • Venting on the transmitter side • Checking the pressure transmitter characteristic 2/220 Siemens FI 01 · 2009 When ordering accessory set or mounting together with the multiway cock, please use Order code; otherwise use Order No. Flange connections to DIN 19213 only permissible up to 160! © Siemens AG 2008 SITRANS P measuring instruments for pressure Fitttings - Shut-off valves for differential pressure transmitters 3- and 5-spindle valve manifolds for vertical angular differential pressure lines Accessory set (connection between manifold and transmitter) • K36: 4 screws 7/16-20 UNF x 1¾ inch to ASME B18.2.1, 2 flat gaskets • K16: 4 screws M10x45 to DIN EN 24014, 4 washers, 2 flat gaskets Washers Ø 10.5 to DIN 125 54 76,2 41,3 Ø12 55 47 ¼-NPT B M8 38 76 115 134 242 Flat gaskets made of PTFE, max. 420 bar, 80 °C Note: Flange connection with M10 screws only permissible up to PN 160! Mounting bracket for wall mounting or for securing to mounting rack 40 ■ Accessories C A ½-NPT 31,75 5-spindle valve manifold 7MF9413-1E. for vertical differential pressure lines, dimensions in mm With bolts for mounting on valve manifold • M17: For 3-spindle valve manifold • M18: For 5-spindle valve manifold Mounting bracket for mounting on 2" standpipe 8 72 With bolts for mounting on valve manifold • M19: For 3-spindle valve manifold Mounting clips (2 off) 72 For securing the mounting brackets M17, M18 and M19 to pipe 60,3 110 180 Valve manifold 100 bar, suitable for oxygen • For 3-spindle valve manifold • For 5-spindle valve manifold ■ Characteristic curves 26 19 38 76 300 420 bar at 120 °C 350 bar at 200 °C 200 Mounting bracket (7MF9006-6NA)/(M17) for 3-spindle valve manifolds, dimensions in mm 100 0 100 200 300 400 °C Operating temperature Permissible operating pressure as a function of the permissible operating temperature 72 0 8 Operating pressure bar 400 72 ■ Dimensional drawings Ø12 M8 38 76 89 197 1/2NPT B A 17 26 9 19 76,2 47 55 41,3 180 54 60,3 155 38 76 31,75 Mounting bracket (7MF9006-6PA)/(M18) for 5-spindle valve manifolds, dimensions in mm 3-spindle valve manifold 7MF9413-1D. for vertical differential pressure lines, dimensions in mm Siemens FI 01 · 2009 2/221 2 © Siemens AG 2008 SITRANS P measuring instruments for pressure Fitttings - Shut-off valves for differential pressure transmitters 100 72 5 3- and 5-spindle valve manifolds for vertical angular differential pressure lines 8 2 72 76 16 19 50 9 38 92 26 Mounting bracket (7MF9006-6QA)/(M19) for 3-spindle and 5-spindle valve manifolds, dimensions in mm ■ Schematics A A A Process connection B Transmitter connection B B 3-spindle valve manifold for vertical differential pressure lines, connections A A A Process connection B Transmitter connection C Vent/test connection 1/4-18 NPT C C B B 5-spindle valve manifold for vertical differential pressure lines, connections 2/222 Siemens FI 01 · 2009 © Siemens AG 2008 SITRANS P measuring instruments for pressure Fitttings - Shut-off valves for differential pressure transmitters Low-pressure multiway cock ■ Overview Order No. Selection and Ordering data Low-pressure multiway cock for liquids and gases, for flanging to pressure transmitters, max. working pressure 25 bar, max. working temperature 60 °C (up to 80 °C for a short time), weight 1.75 kg (without accessory set) 2 Test connections 2x sealing screws G3/8 7MF9004-4CA 2x quick-release couplings 7MF9004-4DA Selection and Ordering data Order code Order No. L31 7MF9004-5CC Further designs1) Please add "-Z" to Order No. and specify Order code. Accessory set to EN (required for flanging, weight 0.2 kg) The low-pressure multiway cock 7MF9004-4CA/-4DA can be flanged to pressure transmitters for differential pressure. ■ Benefits • Robust design • For liquids and gases • One-hand operation ■ Design 4x screws 7/16-20 UNF x 1 inch to ASME B18.2.1; chromized steel 2x gaskets made of PTFE, max. permissible temperature 80 °C Accessory set to DIN (required for flanging, weight 0.2 kg) 4x screws M10x25 to DIN EN 24017; chromized steel 4x washers Ø 10.5 mm to DIN 125; 2x gaskets made of PTFE, max. permissible temperature 80 °C • Standard design L11 7MF9004-6AD The multiway cock has 2 process connections and 2 test connections, which are available in 2 versions (with sealing screws G3/8 or quick-release couplings). The housing is made of hotpressed brass CuZn39Pb3, CW 614N. Test connections with sealing screws or with self-sealing quick-release couplings. • Version for oxygen L15 7MF9004-6AE Note: An accessory set is always required for flanging of the multiway cock to a differential pressure transmitter. Mounting bracket required for wall mounting or for securing on rack (72 mm grid), made of electrogalvanized sheetsteel, weight 0.85 kg ■ Function • Shutting off the differential pressure lines • Testing the pressure transmitter zero • Testing the pressure transmitter characteristic Multiway cock in oil-free and grease-free design BAM-tested lubricant, gasket suitable for oxygen 1) S11 M13 7MF9004-6AA When ordering accessory set or mounting together with the multiway cock, please use Order code; otherwise use Order No. ■ Accessories Accessory set for low-pressure multiway cock • L11: 4 screws M10x25 to DIN EN 24017, 4 washers, 2 flat gaskets • L15 (suitable for oxygen): 4 screws M10x25 to DIN EN 24017, 4 washers, 2 flat gaskets • L31: 4 screws 7/16-20 UNF x 1 inch, 2 flat gaskets Cock positions; the symbols are printed on the cock Washers Ø 10.5 to DIN 125 Flat gaskets made of PTFE, max. permissible temperature 80 °C Multiway cock in oil-free and grease-free design • S11: BAM-tested lubricant, gasket suitable for oxygen Mounting brackets • M13: Required for wall mounting or for securing on rack (72 mm grid); made of electrogalvanized sheet-steel Siemens FI 01 · 2009 2/223 © Siemens AG 2008 SITRANS P measuring instruments for pressure Fitttings - Shut-off valves for differential pressure transmitters Low-pressure multiway cock ■ Options Low-pressure multiway cock, permissible operating pressure as a function of the permissible operating temperature ■ Dimensional drawings Low-pressure multiway cock 7MF9004-4CA/-4DA for direct flanging to pressure transmitters for differential pressure, dimensions in mm 40 6 90 19 70 2 ■ Characteristic curves Test connections • 2 sealing screws G3/8 • 2 quick-release couplings 72 120 o11 24 60 Mounting bracket 7MF9004-6AA (M13), dimensions in mm 2/224 Siemens FI 01 · 2009 © Siemens AG 2008 SITRANS P measuring instruments for pressure Fittings - Accessories Oval flange ■ Overview Order No. Selection and Ordering data Oval flange with female thread ½-14 NPT, max. working pressure 420 bar, flange connection to DIN EN 61518, form A 2 Material P250GH, mat. No.: 1.0460 7MF9408-2CE X 2 CrNiMo 17 13 2, mat. No. 1.4404/316L 7MF9408-2CL Order code Order No. 2x screws 7/16-20 UNF x 1½ inch to ASME B 18.2.3; chromized steel 1x flat gasket made of PTFE, max. permissible 420 bar, 80 °C E36 7MF9408-5DA 2x screws 7/16-20 UNF x 1½ inch to ASME B 18.2.3; chromized steel 1x O-ring to DIN 3771, 20 x 2.65 - S - FPM90, max. permissble 420 bar, 120 °C E34 7MF9408-5CA 2x screws M10x40 to DIN EN ISO 4762; chromized steel 2x washers Ø 10.5 mm to DIN 125; 1x O-ring to DIN 3771, 20 x 2.65 - S - FPM90, max. permissble 420 bar, 120 °C2) E13 7MF9408-6AA E16 7MF9408-6BA Flat gaskets made of PTFE, max. 420 bar, 80 °C 2x screws M10x40 to DIN EN ISO 4762; chromized steel 2x washers Ø 10.5 mm to DIN 125; 1x flat gasket made of PTFE, max. permissible 420 bar, 80 °C2) O-ring to DIN 3771, 20 x 2.65 – S – FPM90, max. 420 bar, 120 °C 1) Note: M10 screws only permissible up to PN 160! 2) Selection and Ordering data Further designs Please add "-Z" to Order No. and specify Order code. Accessory set to EN1) The oval flange 7MF9408-2C. for pressure transmitters for absolute pressure and differential pressure has a ½-14 NPT female thread and is designed for max. operating pressure 400 bar. ■ Accessories • E34: 2 screws 7/16-20 UNF x 1½ inch to ASME B18.3, 1 O-ring (FPM 90) • E13: 2 screws M10x40 to DIN EN 4762, 2 washers, 1 O-ring (FPM 90) • E36: 2 screws 7/16-20 UNF x 1½ inch to ASME B18.2.1, 1 flat gasket • E16: 2 screws M10x40 to DIN EN ISO 4762, 2 washers, 1 flat gasket Washers Ø 10.5 to DIN 125 Accessory set to DIN1) When ordering accessory set together with the oval flange, please use Order code; otherwise use Order No. Flange connections with M10 screws only permissible up to PN 160! ■ Dimensional drawings Oval flange 7MF9408-2C., dimensions in mm Siemens FI 01 · 2009 2/225 © Siemens AG 2008 SITRANS P measuring instruments for pressure Fittings - Accessories Adapters, connection glands ■ Overview ■ Dimensional drawings Adapters enable e.g. a transition from medium connections with NPT thread to shut-off valves to DIN 16270 ... 16272 or pipes in conjunction with a connection gland (e.g. 7MF9008). 2 ■ Design The connection pieces are made of X 6 CrNiMoTi 17 12 2, mat. No. 1.4571 and available in 3 versions • Thread ¼-18 NPT and connection shank G½ to DIN EN 837-1 • Thread ½-14 NPT and connection shank G½ to DIN EN 837-1 • Thread ½-14 NPT and thread ½-14 NPT Selection and Ordering data Connection piece with thread ¼-18 NPT and connection shank G½ 7MF9001-1AA, dimensions in mm Order No. Adapter (weight 0.2 kg) with thread ¼-18 NPT – G½ 7MF9001-1AA with thread ½-14 NPT – G½ 7MF9001-1CA with thread ½-14 NPT – ½-14 NPT 7MF9001-1DA with thread ½-14 NPT – M20 x 1.5 7MF9001-1EA Connection piece with thread ½--14 NPT and connection shank G½ 7MF9001-1CA, dimensions in mm Connection piece with thread ½-14 NPT and thread ½-14 NPT 7MF9001-1DA, dimensions in mm Connection piece with thread ½-14 NPT and thread M20 x 1.5 7MF9001-1EA, dimensions in mm ■ Overview ■ Dimensional drawings Connection glands to connect medium or differential pressure lines to collars G½ to DIN EN 837-1 • For rated pressures up to PN 630 • For oxygen only up to PN 250 Selection and Ordering data Order No. Connection screwed gland for pipelines (weight 0.2 kg) Material Design 11SMn30 (mat. No. 1.0715) Standard 7MF9008-1GA X 6 CrNiMoTi 17 12 2 Standard (mat. No. 1.4571/316Ti) 7MF9008-1GB X 6 CrNiMoTi 17 12 2 Grease-free (mat. No. 1.4571/316Ti) 7MF9008-1GC 2/226 Siemens FI 01 · 2009 Connection gland 7MF9008-1G., dimensions in mm © Siemens AG 2008 SITRANS P measuring instruments for pressure Fittings - Accessories Connection parts G 1/2 ■ Dimensional drawings Selection and Ordering data CW 614N Union nut 9 SMn 28 k Nipple: RSt 37-2 16 M20 x 1,5 30 16 Ø7 SW 27 M56340-A0001 M56340-A0002 1.0715 Ø 14 Nipple connection (M20 x 1.5) M56340-A0008, dimensions in mm 1.0037 Union nut X 8 CrNiS 18 9 1.4305 Nipple: X 6 CrNiMoTi 17 12 2 1.4571/316Ti M56340-A0003 Nipple connection M20 x 1.5 to DIN 16284 (union nut with nipple and gasket); max. working pressure 400 bar; weight 0.1 kg; connection: G½ to DIN EN 837-1; Female thread G½ Material Ø 12 48 Mat. No. SW 27 Nipple connection (G) M56340-A0001 to -A0003, dimensions in mm Nipple connection G½ to DIN 16284 (union nut with nipple and gasket); max. working pressure 400 bar; weight 0.1 kg; connection: G½ to DIN EN 837-1; Female thread G½ CuZn39Pb3 G½ 2 Order No. Adapters G½ for pressure gages and shut-off fittings Material Ø7 30 Connection parts G½ for pressure gages and shut-off fittings are available in 3 versions: • Nipple connection • Clamping sleeve • Collar connection piece 48 ■ Overview Clamping sleeve M56340-A0004/-A0005, dimensions in mm Mat. No. Union nut X 8 CrNiS 18 9 1.4305 Nipple: X 6 CrNiMoTi 17 12 2 1.4571/316Ti M56340-A0008 Clamping sleeve G½ to DIN 16283; max. working pressure 400 bar; weight 0.1 kg; Connections: G½ to DIN EN 837-1; Female thread: G½ right-hand G½ left-hand Collar connection piece M56340-A0006/-A0007, dimensions in mm Material Mat. No. CuZn39Pb3 CW614N M56340-A0004 9 SMn 28 k 1.0715 M56340-A0005 Collar-adapter max. working pressure; weight 0.1 kg; Connections: G½ to DIN EN 837-1; Male thread: G½, G½ Material Mat. No. CuZn39Pb3 CW614N M56340-A0006 9 SMn 28 k 1.0715 M56340-A0007 Siemens FI 01 · 2009 2/227 © Siemens AG 2008 SITRANS P measuring instruments for pressure Fittings - Accessories Water traps, Sealing rings to EN 837-1 ■ Overview ■ Overview Water traps protect pressure gages and shut-off fittings from heating up (e.g. by steam) by the water column produced by the water trap. The max. working temperature is 120 °C at 160 bar, 300 °C at 80 bar or 400 °C at 63 bar. If the temperature of the measured medium is higher, a sufficiently long line has to be connected upstream of the trap to enable heat dissipation. ■ Dimensional drawings ■ Design The water traps are available in U shape (type B) or circular shape (type D) to DIN 16282. They have a weld-on end Ø 20 mm × 2.6 mm on the measurement side. The connection on the device side is a clamping sleeve G½ to DIN 16283. The water traps are made of steel (P250GH) or stainless steel (X 6 CrNiMoTi 17 12 2) Water traps are designed as standard for max. operating temperature 120 °C at max. operating pressure 160 bar (300 °C at 80 bar, 400 °C at 63 bar). Water traps for higher operating pressures and temperatures are available on request. Selection and Ordering data Order No. Water traps for pressure gages and pressure transmitters, max. working temperature 120 °C, max. working pressure 160 bar (or 400 °C and 104 bar), weight 0.7 kg Mat. No. P235GH 1.0345 X 6 CrNiMoTi 17 12 2 1.4571/316Ti M56340-A0043 M56340-A0061 Water trap D to DIN 16282 Material Mat. No. P235GH 1.0345 X 6 CrNiMoTi 17 12 2 1.4571/316Ti M56340-A0045 M56340-A0063 ■ Dimensional drawings Water traps, type B, M56340-A0043/-A0061, dimensions in mm Water traps, type D, M56340-A0045/-A0063, dimensions in mm 2/228 Siemens FI 01 · 2009 Sealing ring 7MF9007-7A. to EN 837-1, dimensions in mm Order No. Selection and Ordering data Sealing ring to EN 837-1 for thread G½ made of (packing unit 100 pcs) • copper F) 7MF9007-7AA • soft iron F) 7MF9007-7AB • stainless steel, mat.-No. 1.4571 F) 7MF9007-7AC • PTFE F) 7MF9007-7AD F) Subject to export regulations AL: 9I999, ECCN: N. Water trap B to DIN 16282 Material 2 The sealing rings to EN 837-1 are required to seal measuring instruments for pressure with the process connection G½B. © Siemens AG 2008 SITRANS P measuring instruments for pressure Fittings - Accessories Pressure surge reducers ■ Overview The pressure surge reducer protects the pressure gage against damage, premature wear and tear and inaccurate/fluctuating indications. 2 ■ Application The pressure reducer is used when pulsations occur in the measured medium (e.g. in slow-running vapor engines, piston pumps and compressors), or if drastic fluctuations are likely to occur in the measured medium (e.g. in hydraulic presses and tensile testing machines). ■ Design • • • • Enclosure made of brass or stainless steel Adjustable nozzle Sleeve for connection to the measuring instrument Pin for connection to supply lead Order No. Selection and Ordering data Pressure surge reducer Weight approx. 0,21 kg Material Full-scale value Weight approx. in kg Brass 250 bar 0.21 M56340-A54 Stainless steel 600 bar 0.21 M56340-A59 ■ Dimensional drawings *® 6OHHYHIRUFRQQHFWLRQ WRWKHSUHVVXUHGLVSOD\ 3LQIRUFRQQHFWLRQ WRVXSSO\OHDG *® Pressure surge reducer, dimensions in mm Siemens FI 01 · 2009 2/229 © Siemens AG 2008 SITRANS P measuring instruments for pressure Fittings - Accessories Primary shut-off valves ■ Overview Ø80 95 The shut-off valves are available in various materials and with various connections (see Selection and Ordering data) ■ Characteristic curves 500 Ø11,2 Ø11,2 bar 400 G½ 22 300 Operating pressure C B 200 D E 90 22 G½ Shut-off valve 7MF9017–1A., dimensions in mm A Ø80 100 0 0 100 200 300 400 500 600 °C 95 Operating temperature bar bar 500 500 400 400 300 300 G 200 H G½ 22 90 M20x1,5 Shut-off valve 7MF9017-1B. and -2B., dimensions in mm K Ø80 200 F 100 Ø11,2 Shut-off valve 7MF9017-1.., permissible working pressure as a function of the permissible working temperature Ø11,2 Shut-off valve 7MF9017-1.. J 100 0 200 300 400 °C 0 100 200 °C Operating temperature Shut-off valve 7MF9017-2.. Shut-off valve 7MF9017-3.. Shut-off valve 7MF9017-2.. and -3.., permissible working pressure as a function of the permissible working temperature M20x1,5 (M22x1,5) Ø12 (Ø14) 100 95 0 0 Ø12 (Ø14) Operating pressure 2 ■ Dimensional drawings Primary shut-off valves are available in the following versions: • For non-corrosive liquids, gases and vapors • For corrosive liquids and gases • Grease-free for oxygen 90 M20x1,5 (M22x1,5) Shut-off valves 7MF9017-1C., -1D. and -2C., dimensions in mm 2/230 Siemens FI 01 · 2009 © Siemens AG 2008 SITRANS P measuring instruments for pressure Fittings - Accessories Primary shut-off valves ØAxb 7MF9017- 14 mm x 2.5 mm 1F. and 1G. 21.3 mm x 6.3 mm 1H. and 2H. 24 mm x 7.1 mm 1J., 1K. and 2J. 2 141 Ø120 Øa Ø14 b 2,5 5 65 4,5 130 Shut-off valves 7MF9017-, dimensions in mm Selection and Ordering data Primary shut-off valves, without certificate Max. Charac- Material Mat. No. Spindle working teristic1) thread pressure Shut-off valve for non-aggressive liquids, gases and vapors 160 bar A P250GH 1.0460 Internal 160 bar A P250GH 1.0460 Internal 400 bar C P250GH 1.0460 Internal 400 bar C P250GH 1.0460 Internal 500 bar 500 bar 500 bar D E D 16 Mo 3 11 CrMo 9 10 16 Mo 3 1.5415 1.7383 1.5415 External External External 500 bar D 16 Mo 3 1.5415 External 500 bar E 11 CrMo 9 10 1.7383 External Shut-off valve for aggressive liquids and gases 160 bar F X 6 CrNiMoTi 17 12 2 1.4571/ 316Ti Internal 400 bar G X 6 CrNiMoTi 17 12 2 1.4571/ 316Ti Internal 400 bar H External 400 bar H X 6 CrNiMoTi 17 12 2 1.4571/ 316Ti X 6 CrNiMoTi 17 12 2 1.4571/ 316Ti External Connections Approx. weight kg Threaded socket G½ form R, DIN 19207 Threaded socket G½ form R, DIN 19207 DIN 19207 and pipe union with ferrule for pipe ∅ 12 mm, S series Pipe union with ferrule for pipe ∅ 12 mm, S series Pipe union with ferrule for pipe ∅ 14 mm, S series Welding sleeves ∅ 14 mm × 2.5 mm Welding sleeves ∅ 14 mm × 2.5 mm Welding sleeves ∅ 21.3 mm × 6.3 mm and ∅ 14 mm × 2.5 mm Welding sleeves ∅ 24 mm × 7.1 mm and ∅ 14 mm × 2.5 mm Welding sleeves ∅ 24 mm × 7.1 mm and ∅ 14 mm × 2.5 mm 0.8 0.8 Threaded socket G½ form R, DIN 19207 DIN 19207 and pipe union with ferrule for pipe ∅ 12 mm, S series Pipe union with ferrule for pipe ∅ 12 mm, S series 0.8 1 C Welding sleeves ∅ 21.3 mm × 6.3 mm and ∅ 14 mm × 2.5 mm Welding sleeves ∅ 24 mm × 7.1 mm and ∅ 14 mm × 2.5 mm 1.6 H 1.6 J Accessories Factory test certificate EN 10204–2.2 Material acceptance test certificate EN 10204-3.1 1) Order No. 7MF 9 0 1 7 - 1 7A A B 1 C 1 D 1.6 1.6 1.6 F G H 1.6 J 1.6 K 7MF 9 0 1 7 - 2 7A B 7MF9000-8AB 7MF9000-8AD See Figure "Permissible working pressure as a function of the permissible working temperature" Siemens FI 01 · 2009 2/231 © Siemens AG 2008 SITRANS P measuring instruments for pressure Fittings - Accessories Compensation vessels ■ Overview ■ Dimensional drawings The compensation vessels prevent the level difference which occurs with pressure changes in the pressure lines and which falsifies the measurement. 9 According to DIN 19211, the temperature in the compensation vessel must be assumed to be 50 K less than the steam temperature in the pipe when calculating the wall thicknesses. This is because the temperature in the compensation vessel during operation can only rise up to the saturated steam temperature. 88, 100 I A material acceptance test certificate A to EN 10204-3.1 is available for the materials from which the compensation vessels are made. ■ Characteristic curves O O I bar Output (see Ordering data for dimensions) Input (see Ordering data for dimensions) 500 Compensation vessel 7MF9015-1.., dimensions in mm 400 E D 65 approx. 110 300 C 200 I 35 1) 58 1) Operating pressure 2 100 B A 100 0 0 100 200 Operating temperature 300 400 O 500 600 I O 1) °C Input (see Ordering data for dimensions) Output (see Ordering data for dimensions) 30 mm longer with 7MF9015-5A. Compensation vessel 7MF9015-5.., dimensions in mm Permissible operating pressure as a function of the permissible operating temperature Selection and Ordering data Compensation vessel, without certificate Max. Characteristic1) Material Mat. No. Connections working Input pressure 160 bar A 16 Mo 3 1.5415 250 bar B 16 Mo 3 1.5415 250 bar B 16 Mo 3 1.5415 250 bar C 11 CrMo 9 10 1.7383 250 bar B 16 Mo 3 1.5415 160 bar A 16 Mo 3 1.5415 500 bar D 16 Mo 3 1.5415 500 bar D 16 Mo 3 1.5415 500 bar E 11 CrMo 9 10 1.7383 Threaded socket G½, form R, DIN 19207 Welding sleeve ∅ 21 mm × 6.3 mm Welding sleeve ∅ 24 mm × 7.1 mm Welding sleeve ∅ 24 mm × 7.1 mm Welding sleeve ∅ 33.7 mm × 4.5 mm Threaded socket G½, form R, DIN 19207 Welding sleeve ∅ 21 mm × 6.3 mm Welding sleeve ∅ 24 mm × 7.1 mm Welding sleeve ∅ 24 mm × 7.1 mm Output Threaded socket G½, form V, DIN 19207 Welding sleeve ∅ 21.3 mm × 6.3 mm Welding sleeve ∅ 24 mm × 7.1 mm Welding sleeve ∅ 24 mm × 7.1 mm Welding sleeve ∅ 24 mm × 7.1 mm Threaded socket G½, form V, DIN 19207 Welding sleeve ∅ 21.3 mm × 6.3 mm Welding sleeve ∅ 24 mm × 7.1 mm Welding sleeve ∅ 24 mm × 7.1 mm Accessories Factory test certificate EN 10204–2.2 Material acceptance test certificate EN 10204-3.1 1) See Figure "Permissible working pressure as a function of the permissible working temperature" 2/232 Siemens FI 01 · 2009 Approx. Approx. contents weight cm³ kg Order No. 7 MF 9 0 1 5 - 77A 1A 250 0.8 250 0.8 1B 250 1 1C 250 1 1D 250 0.7 1E 20 1.6 5A 20 1.6 5B 20 1.6 5C 20 1.6 5D 7MF9000-8AB 7MF9000-8AD © Siemens AG 2008 SITRANS P measuring instruments for pressure Fittings - Accessories Connection parts ■ Overview ■ Dimensional drawings Connection parts are available in the following versions: • Threaded flange pair G½ with stainless steel gasket • Nipple G½ form V to DIN 19207 • Union nut G½ made of C 35 to DIN 16284 • Gasket B½ (grooved) to DIN 19207 2 All connection parts are also available grease-free for oxygen. Selection and Ordering data Order No. Threaded flange pair G½ • with stainless steel gasket 7MF9007-4CA • grease-free for oxygen, with stainless steel gasket 7MF9007-4DA Scope of delivery: Threaded flange 7MF9007-4CA/-4DA, dimensions in mm 2x threaded flanges G½ to DIN 19207; material: P250GH (mat. No. 1.0460) 4x hexagon screws M10x45 to DIN EN 24014; Material: C35E (mat. No. 1.1181) 4x hexagon screws M10x50 to DIN EN 24032 1x gasket G½ (7MF9007-6BA) grooved, to DIN 19207; Material: X 6 CrNiMoTi 17 12 2 (mat. No. 14571/316Ti) Only for 7MF9007-4CA! Nipple G½ 7MF9007-4KA/-4LA, dimensions in mm 1x gasket G½ (7MF9k007-6CA), grease-free for oxygen, grooved, to DIN 19207; Material: X 6 CrNiMoTi 17 12 2 (mat. No. 14571/316Ti) Only for 7MF9007-4DA! Union nut G½ 7MF9007-4MA/-4NA, dimensions in mm Nipple G½ to DIN 19207 • Material: 16 Mo 3 (mat. No. 1.5415) 7MF9007-4KA • grease-free for oxygen, Material: X 6 CrNiMoTi 17 12 2 (mat. No. 1.4571/316Ti) 7MF9007-4LA Gasket 7MF9007-6BA/-6CA, dimensions in mm 7 Union nut G½ to DIN 16284 • Material: C35E (mat. No. 1.1181) 7MF9007-4MA • grease-free for oxygen, Material: X 6 CrNiMoTi 17 12 2 (mat. No. 1.4571/316Ti) 7MF9007-4NA Gasket G½ to DIN 19207, grooved • Material: X 6 CrNiMoTi 17 12 2 (mat. No. 1.4571/316Ti) F) 7MF9007-6BA • grease-free for oxygen, Material: X 6 CrNiMoTi 17 12 2 (mat. No. 1.4571/316Ti) F) 7MF9007-6CA F) Subject to export regulations AL: 9I999, ECCN: N. Siemens FI 01 · 2009 2/233 © Siemens AG 2008 SITRANS P measuring instruments for pressure 2 2/234 Siemens FI 01 · 2009
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Page Mode : UseOutlines XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Producer : Acrobat Distiller 8.1.0 (Windows) Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2008:09:01 16:42:41+02:00 Create Date : 2008:08:21 10:38:01+02:00 Metadata Date : 2008:09:01 16:42:41+02:00 Document ID : uuid:89f33096-8743-4991-863d-a9eb43af7e25 Instance ID : uuid:0ecd9642-6807-4992-bf75-7eb85b7c4166 Format : application/pdf Title : FI01_2009_en_kap02.book Creator : STROZYKW Page Count : 234 Page Layout : SinglePage Author : STROZYKWEXIF Metadata provided by EXIF.tools