Siemens Water Heater 600 Users Manual SINVERT PVS 600Series Central Inverters And Components For Photovoltaic Power Plants
600Series SINVERT_PVS_Brochure_English_2012-04
600 to the manual 5b7da654-533a-46af-a993-2cc23d8ee3a3
2015-02-05
: Siemens Siemens-Water-Heater-600-Users-Manual-410660 siemens-water-heater-600-users-manual-410660 siemens pdf
Open the PDF directly: View PDF .
Page Count: 32
Download | |
Open PDF In Browser | View PDF |
© Siemens AG 2012 Photovoltaics SINVERT PVS 600Series Central Inverters and Components for Photovoltaic Power Plants Brochure · April 2012 SINVERT Answers for the environment. © Siemens AG 2012 Sunny prospects for photovoltaic plants The SINVERT PVS 600Series central inverters from 500 to 2 520 kW: compact, robust, durable Whether on the roofs of large industrial facilities, in ground-mounted PV systems, or solar power plants – you can now utilize the power of the sun even more efficiently: with the new three-phase SINVERT PVS 600Series photovoltaic inverters. With these inverters you can achieve a peak efficiency of 98.7% and a European efficiency of 98.4% when converting solar power for feeding into the grid. The SINVERT PVS inverters operate in inverter stations according to the Siemens master-slave concept that has been proven in use now for more than a decade, and that stands for maximum plant availability, a particularly long service life, and optimized efficiency. Peak efficiency you can count on! 2 Sunny prospects for photovoltaic plants Inverter stations with SINVERT PVS inverters are system solutions for simple and fast implementation of photovoltaic power plants. Additional system components and accessories required for this purpose are available. The SINVERT Select dimensioning program helps to find the best possible configuration for a photovoltaic plant. A modular service concept means that services can be tailored to different needs as required. The SINVERT PVS inverters are characterized by their ruggedness and longevity, which we back up with a five-year manufacturer's warranty as standard. © Siemens AG 2012 Contents text Introduction Sunny prospects for photovoltaic plants . . . . . . . . . . . 2 SINVERT PVS 600Series central inverters . . . . . . . . . 4 Features and advantages at a glance. . . . . . . . . . . . . . 4 Technical data of the PVS500 (IEC) . . . . . . . . . . . . . . . 6 Technical data of the PVS585 (IEC) . . . . . . . . . . . . . . . 7 Technical data of the PVS600 (IEC) . . . . . . . . . . . . . . . 8 Technical data of the PVS630 (IEC) . . . . . . . . . . . . . . . 9 Options for SINVERT PVS 600Series inverters . . . . . . 10 SINVERT PVS in power plants . . . . . . . . . . . . . . . . . 12 How solar power is fed into the AC grid. . . . . . . . . . . 12 SINVERT PVS CombinerBoxes for bundling: single-stage concept, two-stage concept . . . . . . . . . 12 IEC-compliant inverter stations . . . . . . . . . . . . . . . . . 14 - Master-slave system with SINVERT PVS . . . . . . . . . . 15 - Medium-voltage components . . . . . . . . . . . . . . . . . 15 Establishing communication with PVS and system components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 - SINVERT PVS ComBox 100 . . . . . . . . . . . . . . . . . . . . 16 - SINVERT PVS ControlBox 300 . . . . . . . . . . . . . . . . . . 16 - SINVERT PVS ComBox 200 . . . . . . . . . . . . . . . . . . . . 18 - SINVERT PVS WeatherStation 200 . . . . . . . . . . . . . . 18 PV plant dimensioning with SINVERT Select . . . . . 20 PV plant monitoring . . . . . . . . . . . . . . . . . . . . . . . . 21 with WinCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 with SINVERT WebMonitor . . . . . . . . . . . . . . . . . . . . . 22 Selection and ordering data for devices and accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Service & Support . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Spare parts service: On-demand spare parts delivery, PVS SparesKits. . . . 28 Service calls: Commissioning, On-site service, Maintenance . . . . . 28 Service contracts . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 - SINVERT PVS SparesContract . . . . . . . . . . . . . . . . . . 30 - SINVERT PVS WarrantyExtension . . . . . . . . . . . . . . . 30 - SINVERT PVS MaintenanceContract . . . . . . . . . . . . . 31 - SINVERT PVS FullServiceContract . . . . . . . . . . . . . . . 31 Sunny prospects for photovoltaic plants 3 © Siemens AG 2012 SINVERT PVS 600Series central inverters Features and advantages at a glance Transformerless, 3-phase SINVERT PVS inverters are reliable, grid-compatible and cost-effective photovoltaic inverters which are used to convert solar energy into grid-compliant AC voltage for feeding into conventional power grids – thereby achieving peak efficiency levels of up to 98.7%. Photovoltaic plants in which SINVERT PVS inverters are used can be monitored and controlled with the WinCC visualization system installed on a Windows PC. WinCC gives transparency to the status and energy flow of the entire plant, from the photovoltaic array and the inverters right up to the grid connection (see page 21). The compact SINVERT PVS inverters are ideal for use in medium and large-scale photovoltaic power plants. The free SINVERT WebMonitor web application can also be used for monitoring the photovoltaic plant with SINVERT PVS inverters (see page 22). The SINVERT PVS500, SINVERT PVS585, SINVERT PVS600 and SINVERT PVS630 inverters are grouped together under the name "SINVERT PVS 600Series". They consist of between 1 and 4 subunits and are available for outputs of between 500 and 2 520 kW in the following power levels: – SINVERT PVS500: 500, 1 000, 1 500, 2 000 kW – SINVERT PVS585: 585, 1 170, 1 755, 2 340 kW – SINVERT PVS600: 600, 1 200, 1 800, 2 400 kW – SINVERT PVS630: 630, 1 260, 1 890, 2 520 kW The IEC-compliant devices are also available already integrated in an inverter station (with two to four subunits), including medium-voltage components. Besides SINVERT PVS and inverter stations, additional system components and accessories are available for implementing photovoltaic power plants according to IEC standards (see page 12). With the MobileApp of the SINVERT WebMonitor, it is possible to call up the current and historical data of the selected photovoltaic plant remotely at any time, using a smartphone or tablet computer (see page 22). Your benefits at a glance: ■ Cost-effectiveness – Good price/performance ratio – Low installation costs – High plant yields thanks to maximum efficiency over very large power ranges – Low operating costs thanks to the robust, durable and low-maintenance design – Reduced operating costs throughout the entire operating period thanks to the master-slave principle with rotating master, in which up to four inverter subunits are interconnected (see page 15) ■ Reliability – Use of fully developed, tried-and-tested industrial standard components – Automatic diagnosis and signaling of faults – Competent, professional support, worldwide service – Modular service concept – Compliance with the relevant guidelines ■ Transparency – Central unit of the photovoltaic plant – Automatic diagnostics on site or by means of remote monitoring – Pixel-graphics display with touch screen on the front of the control cabinet enables simple and intuitive operation and visualization of infeed power data and other information The modularity of the series and the free SINVERT Select dimensioning software allow flexible planning of photovoltaic plants (see page 20). To obtain early warning of faults and creeping change due to aging and wear, monitoring and control of a PV power plant via a central control room is absolutely essential. Only in this way can the operator initiate repairs and maintenance measures at an early stage and thus avoid costly downtimes. Central monitoring and control is therefore also an essential part of a preventive maintenance system. 4 SINVERT PVS 600Series central inverters © Siemens AG 2012 SINVERT PVS 600Series Inverter type Power / kW 500 1000 1500 2000 PVS500 PVS585 PVS600 PVS630 PVS1000 PVS1170 PVS1200 PVS1260 PVS1500 PVS1755 PVS1800 PVS1890 PVS2000 PVS2340 PVS2400 PVS2520 Power levels of the SINVERT PVS 600Series central inverters SINVERT PVS 600Series central inverter (subunit) SINVERT PVS 600Series central inverters 5 © Siemens AG 2012 Technical data of the SINVERT PVS500 inverter (according to IEC)1) Inverter type PVS500 PVS1000 PVS1500 PVS2000 V 450 ... 750 450 ... 750 450 ... 750 450 ... 750 Input DC MPP voltage Maximum input voltage2) V 820 820 820 820 Minimum input voltage V 450 450 450 450 Rated input power kW 513 1 026 1 539 2 052 Maximum input current A 1 103 2 206 3 309 4 412 3 6 9 12 368 368 368 368 Type 2 Type 2 Type 2 Type 2 Number of DC inputs Maximum current per DC input A Surge arrester Output AC Grid connection 50/60 Hz 288 V 3 AC 50/60 Hz 288 V 3 AC 50/60 Hz 288 V 3 AC 50/60 Hz 288 V 3 AC Rated power kW 500 1 000 1 500 2 000 Maximum output current A 1 002 2 004 3 006 4 008 Line voltage V 244.8 ... 316.8 244.8 ... 316.8 244.8 ... 316.8 244.8 ... 316.8 Power factor, inductive 0.8 0.8 0.8 0.8 Power factor, capacitive 0.8 0.8 0.8 0.8 Efficiency European efficiency factor % 98.1 98.3 98.3 98.3 CEC efficiency factor % 98.2 98.3 98.3 98.3 Maximum efficiency factor % 98.4 98.4 98.4 98.4 1 2 3 4 Further data Number of subunits Dimensions (H/W/D) per subunit mm 2 100 x 2 700 x 730 2 100 x 2 700 x 730 2 100 x 2 700 x 730 2 100 x 2 700 x 730 Weight per subunit kg 2 085 2 085 2 085 2 085 Ambient temperature - during operation - during storage and transport °C °C 0 ... +50 -25 ... +70 0 ... +50 -25 ... +70 0 ... +50 -25 ... +70 0 ... +50 -25 ... +70 Relative humidity % 0 ... 95 0 ... 95 0 ... 95 0 ... 95 Installation altitude - maximum permissible - at rated power m m 2 000 0 ... 1 000 2 000 0 ... 1 000 2 000 0 ... 1 000 2 000 0 ... 1 000 Ethernet Ethernet Ethernet Ethernet Order number (grid frequency 50 Hz) 6AG3111-1AH003AB0 6AG3111-1AH103AB0 6AG3111-1AH203AB0 6AG3111-1AH303AB0 Order number (grid frequency 60 Hz) 6AG3111-2AH003AB0 6AG3111-2AH103AB0 6AG3111-2AH203AB0 6AG3111-2AH303AB0 Data interface Order number 1) 2) 6 Detailed technical information can be found at: http://support.automation.siemens.com With the 1 000 V option, expandable to 1 000 V (see page 10 and 24). SINVERT PVS 600Series central inverters © Siemens AG 2012 Technical data of the SINVERT PVS585 inverter (according to IEC)1) Inverter type PVS585 PVS1170 PVS1755 PVS2340 V 530 ... 750 530 ... 750 530 ... 750 530 ... 750 Input DC MPP voltage Maximum input voltage2) V 820 820 820 820 Minimum input voltage V 530 530 530 530 Rated input power kW 598 1 196 1 794 2 392 Maximum input current A 1 104 2 208 3 312 4 416 3 6 9 12 368 368 368 368 Type 2 Type 2 Type 2 Type 2 Number of DC inputs Maximum current per DC input A Surge arrester Output AC Grid connection 50/60 Hz 340 V 3 AC 50/60 Hz 340 V 3 AC 50/60 Hz 340 V 3 AC 50/60 Hz 340 V 3 AC Rated power kW 585 1 170 1 755 2 340 Maximum output current A 995 1 990 2 985 3 980 Line voltage V 289 ... 374 289 ... 374 289 ... 374 289 ... 374 Power factor, inductive 0.8 0.8 0.8 0.8 Power factor, capacitive 0.8 0.8 0.8 0.8 Efficiency European efficiency factor % 98.2 98.4 98.4 98.4 CEC efficiency factor % 98.3 98.3 98.4 98.4 Maximum efficiency factor % 98.6 98.6 98.6 98.6 1 2 3 4 Further data Number of subunits Dimensions (H/W/D) per subunit mm 2 100 x 2 700 x 730 2 100 x 2 700 x 730 2 100 x 2 700 x 730 2 100 x 2 700 x 730 Weight per subunit kg 2 085 2 085 2 085 2 085 Ambient temperature - during operation - during storage and transport °C °C 0 ... +50 -25 ... +70 0 ... +50 -25 ... +70 0 ... +50 -25 ... +70 0 ... +50 -25 ... +70 Relative humidity % 0 ... 95 0 ... 95 0 ... 95 0 ... 95 Installation altitude - maximum permissible - at rated power m m 2 000 0 ... 1 000 2 000 0 ... 1 000 2 000 0 ... 1 000 2 000 0 ... 1 000 Ethernet Ethernet Ethernet Ethernet Order number (grid frequency 50 Hz) 6AG3111-1AH007AB0 6AG3111-1AH107AB0 6AG3111-1AH207AB0 6AG3111-1AH307AB0 Order number (grid frequency 60 Hz) 6AG3111-2AH007AB0 6AG3111-2AH107AB0 6AG3111-2AH207AB0 6AG3111-2AH307AB0 Data interface Order number 1) 2) Detailed technical information can be found at: http://support.automation.siemens.com With the 1 000 V option, expandable to 1 000 V (see page 10 and 24). SINVERT PVS 600Series central inverters 7 © Siemens AG 2012 Technical data of the SINVERT PVS600 inverter (according to IEC)1) Inverter type PVS600 PVS1200 PVS1800 PVS2400 V 570 ... 750 570 ... 750 570 ... 750 570 ... 750 Input DC MPP voltage Maximum input voltage2) V 820 820 820 820 Minimum input voltage V 570 570 570 570 Rated input power kW 613 1 226 1 839 2 452 Maximum input current A 1 104 2 208 3 312 4 416 3 6 9 12 368 368 368 368 Type 2 Type 2 Type 2 Type 2 Number of DC inputs Maximum current per DC input A Surge arrester Output AC Grid connection 50/60 Hz 370 V 3 AC 50/60 Hz 370 V 3 AC 50/60 Hz 370 V 3 AC 50/60 Hz 370 V 3 AC Rated power kW 600 1 200 1 800 2 400 Maximum output current A 936 1 872 2 808 3 744 Line voltage V 314.5 ... 407 314.5 ... 407 314.5 ... 407 314.5 ... 407 Power factor, inductive 0.8 0.8 0.8 0.8 Power factor, capacitive 0.8 0.8 0.8 0.8 Efficiency European efficiency factor % 98.4 98.6 98.6 98.6 CEC efficiency factor % 98.5 98.6 98.6 98.6 Maximum efficiency factor % 98.7 98.7 98.7 98.7 1 2 3 4 Further data Number of subunits Dimensions (H/W/D) per subunit mm 2 100 x 2 700 x 730 2 100 x 2 700 x 730 2 100 x 2 700 x 730 2 100 x 2 700 x 730 Weight per subunit kg 2 085 2 085 2 085 2 085 Ambient temperature - during operation - during storage and transport °C °C 0 ... +50 -25 ... +70 0 ... +50 -25 ... +70 0 ... +50 -25 ... +70 0 ... +50 -25 ... +70 Relative humidity % 0 ... 95 0 ... 95 0 ... 95 0 ... 95 Installation altitude - maximum permissible - at rated power m m 2 000 0 ... 1 000 2 000 0 ... 1 000 2 000 0 ... 1 000 2 000 0 ... 1 000 Ethernet Ethernet Ethernet Ethernet Order number (grid frequency 50 Hz) 6AG3111-1AH000AB0 6AG3111-1AH100AB0 6AG3111-1AH200AB0 6AG3111-1AH300AB0 Order number (grid frequency 60 Hz) 6AG3111-2AH000AB0 6AG3111-2AH100AB0 6AG3111-2AH200AB0 6AG3111-2AH300AB0 Data interface Order number 1) 2) 8 Detailed technical information can be found at: http://support.automation.siemens.com With the 1 000 V option, expandable to 1 000 V (see page 10 and 24). SINVERT PVS 600Series central inverters © Siemens AG 2012 Technical data of the SINVERT PVS630 inverter (according to IEC)1) Inverter type PVS630 PVS1260 PVS1890 PVS2520 V 570 ... 750 570 ... 750 570 ... 750 570 ... 750 Input DC MPP voltage Maximum input voltage2) V 820 820 820 820 Minimum input voltage V 570 570 570 570 Rated input power kW 643 1 286 1 929 2 572 Maximum input current A 1 104 2 208 3 312 4 416 3 6 9 12 368 368 368 368 Type 2 Type 2 Type 2 Type 2 Number of DC inputs Maximum current per DC input A Surge arrester Output AC Grid connection 50/60 Hz 370 V 3 AC 50/60 Hz 370 V 3 AC 50/60 Hz 370 V 3 AC 50/60 Hz 370 V 3 AC Rated power kW 630 1 260 1 890 2 520 Maximum output current A 985 1 970 2 955 3 940 Line voltage V 314.5 ... 407 314.5 ... 407 314.5 ... 407 314.5 ... 407 Power factor, inductive 0.8 0.8 0.8 0.8 Power factor, capacitive 0.8 0.8 0.8 0.8 Efficiency European efficiency factor % 98.3 98.5 98.5 98.5 CEC efficiency factor % 98.4 98.5 98.5 98.5 Maximum efficiency factor % 98.7 98.7 98.7 98.7 1 2 3 4 Further data Number of subunits Dimensions (H/W/D) per subunit mm 2 100 x 2 700 x 730 2 100 x 2 700 x 730 2 100 x 2 700 x 730 2 100 x 2 700 x 730 Weight per subunit kg 2 085 2 085 2 085 2 085 Ambient temperature - during operation - during storage and transport °C °C 0 ... +50 -25 ... +70 0 ... +50 -25 ... +70 0 ... +50 -25 ... +70 0 ... +50 -25 ... +70 Relative humidity % 0 ... 95 0 ... 95 0 ... 95 0 ... 95 Installation altitude - maximum permissible - at rated power m m 2 000 0 ... 1 000 2 000 0 ... 1 000 2 000 0 ... 1 000 2 000 0 ... 1 000 Ethernet Ethernet Ethernet Ethernet Order number (grid frequency 50 Hz) 6AG3111-1AH008AB0 6AG3111-1AH108AB0 6AG3111-1AH208AB0 6AG3111-1AH308AB0 Order number (grid frequency 60 Hz) 6AG3111-2AH008AB0 6AG3111-2AH108AB0 6AG3111-2AH208AB0 6AG3111-2AH308AB0 Data interface Order number 1) 2) Detailed technical information can be found at: http://support.automation.siemens.com With the 1 000 V option, expandable to 1 000 V (see page 10 and 24). SINVERT PVS 600Series central inverters 9 © Siemens AG 2012 Options for SINVERT PVS 600Series inverters Basic versions and options 1 000 V option The SINVERT PVS 600Series of inverters can be adapted and expanded by means of options in order to meet the individual needs of the plant. The 1 000 V option increases the maximum permissible input voltage of the SINVERT PVS inverter from 820 to 1 000 V. Provision of this option ensures that the PV plant will enter operation smoothly even with voltages in excess of 820 V which can occur, for example, on cold days or in arrays containing thin-film modules. The option thus maximizes the potential yield of the installation. The MPP voltage range of the SINVERT PVS inverter is not changed. The following 4 options are available: – PV array grounding – 1 000 V option – Symmetry monitoring – Cabinet heating Symmetry monitoring PV array grounding In most cases, PV systems constitute a DC IT system. In a DC IT system, neither the positive nor negative pole is grounded. When using certain module types, however, either a positive or negative grounding of the PV generator is required. It is only by this grounding that damage to modules and a steady loss of power can be prevented, i.e. that the maximum yield can be obtained on a continuous basis. The "PV array grounding positive pole" option allows functional grounding of the positive conductor inside the SINVERT PVS inverter if this is a requirement of the photovoltaic modules used (e.g. large number of thick-film modules). The "PV array grounding negative pole" option allows functional grounding of the negative conductor inside the SINVERT PVS inverter if this is a requirement of the photovoltaic modules used (e.g. large number of thin-film modules). PV systems no longer constitute a DC IT system when their modules are grounded. For safety reasons, the PV system must be fenced in and designated as an electrical operating area. Only qualified electricians may be granted access. Grounding an active conductor (positive pole or negative pole) means that the inverter's insulation measuring function no longer works in the normal way. A hazardous current can start to flow as soon as the first insulation damage occurs. For this reason, in the case of positive pole grounding, the current between the positive pole and ground is measured, and in the case of negative pole grounding, the current between the negative pole and ground. When the current increases to a critical level, the ground connection is automatically separated. 10 SINVERT PVS 600Series central inverters The "symmetry monitoring" option measures the normalized currents at the DC inputs internally and cross-compares the values. If this comparison indicates deviations over time, a message is generated. The message can be used as a guide to localizing faults early in sections of the PV generator (e.g. cell failure). Cabinet heating The "cabinet heating" option minimizes the risk of condensation forming on the moisture-sensitive components in the SINVERT PVS photovoltaic inverter at low ambient temperatures. Reliable operation and maximum energy yields to the grid are dependent on compliance with the operating temperature range prescribed for the relevant SINVERT PVS inverter. This function is recommended for locations at which the ambient temperature can drop below 7 °C. Order numbers for the options Each of the four options has its own order number which is to be specified in addition to the order number of the basic version (see "Selection and ordering data", page 23). © Siemens AG 2012 SINVERT PVS inverters for industrial roof systems A SINVERT PVS2000 is used for the Aspropyrgos 2 MW roof system erected in Greece in 2011 for Big Solar SINVERT PVS inverters for solar power plants The 31 MW solar power plant at Les Mées in France was constructed in 2010/2011 for Eco Delta and connected to the grid in August 2011. For this project, Siemens acted as a general contractor with an all-in-one concept from a single source, including maintenance, operation and warranty services. SINVERT PVS500 inverters are in use at this PV solar plant with 112 400 solar modules installed over an area of 66 hectares. The SINVERT Select software was used for the plant dimensioning, and the plant is monitored with WinCC software. SINVERT PVS 600Series central inverters 11 © Siemens AG 2012 SINVERT PVS in power plants Link between solar power and public AC grid How solar power is fed into the AC grid Sunlight is transformed into solar energy in the photovoltaic modules. The direct current obtained is bundled in the field with the aid of SINVERT PVS CombinerBoxes and then fed into a SINVERT PVS inverter (see diagrams on this page). The alternating current supplied by the inverters is transformed by medium-voltage transformers into the higher voltages of 20 kV, for example, that are needed for feed-in to the grid. With the two-stage concept, the module strings are initially brought together in the SINVERT PVS CombinerBoxes (first stage). The outputs of these SINVERT PVS CombinerBoxes are then connected to other SINVERT PVS CombinerBoxes (second stage). The outputs of the SINVERT PVS CombinerBoxes of the second stage are then connected to the inputs of the SINVERT PVS inverters or inverter stations. The advantage of this two-stage concept is that power losses are reduced thanks to the increased cable cross-sections. Photovoltaic modules The inverters and the transformers are in a protected location in inverter stations, as is the optional medium-voltage switchgear, which allows energy to be distributed and fed into the medium-voltage grid (see diagram on page 14). SINVERT PVS CombinerBoxes for bundling partial currents Module strings can be "collected" and their energy transported to the SINVERT PVS inverter or inverter station using a singlestage or two-stage connection concept: SINVERT PVS CombinerBoxes 108 SINVERT PVS CombinerBoxes 204 Photovoltaic array RE10_00026b With the SINVERT PVS CombinerBox, the individual strings of the photovoltaic generator are collected in the field, connected in parallel and the energy conveyed via large cross-section cables to the SINVERT PVS inverter or the inverter station. Service room SINVERT PVS inverters With the single-stage concept, the energy supplied by the module strings to the inputs of the SINVERT PVS CombinerBoxes is transported directly to the SINVERT PVS inverter or the inverter station via one output in each case. SINVERT PVS CombinerBoxes 120 Photovoltaic array The SINVERT PVS CombinerBoxes 108, 120, 124 with eight, twenty, and twenty-four inputs are used in the first stage. The CombinerBox 204 with four inputs is used in the second stage. RE10_00027a Photovoltaic modules Bundling of the solar direct current using SINVERT PVS CombinerBoxes (two-stage concept) Service room SINVERT PVS inverters Bundling of the solar direct current using SINVERT PVS CombinerBoxes (single-stage concept) SINVERT PVS CombinerBoxes 124, 204, 120, 108 (from left to right) 12 SINVERT PVS in power plants © Siemens AG 2012 The SINVERT PVS CombinerBoxes are designed for vertical mounting. The output side of the SINVERT PVS CombinerBoxes can be optionally equipped with or without a switch disconnector. CombinerBoxes with switch disconnectors are capable of disconnecting the connected section of the photovoltaic generator from the SINVERT PVS inverter, e.g. for maintenance work. SINVERT PVS CombinerBox 108 120 124 204 Number of inputs 8 20 24 4 Maximum protection per input 15 A 20 A Voltage 1 000 V Switch disconnector optional Surge arrester opt. 160 A --- The SINVERT PVS CombinerBox 108 is optionally available with or without overvoltage protection, which is designed to protect the modules. The inputs of the SINVERT PVS CombinerBoxes are protected by fuses. The fuses are not included in the scope of supply of the SINVERT PVS CombinerBox and must be ordered separately (see Selection and ordering data on page 25). The SINVERT PVS CombinerBox has IP54 degree of protection and is rated for voltages up to 1 000 V. SINVERT PVS in power plants 13 © Siemens AG 2012 IEC-compliant inverter stations The inverter stations are system solutions for fast, simple implementation of turnkey photovoltaic stations. They are ideally suited for photovoltaic power plants ("Power Plant" segment) with outputs of 1 000 kW upwards. They are typically employed in ground-mounted systems. Inverter stations contain two to four SINVERT PVS inverters and, depending on the selected type, also medium-voltage switchgear and medium-voltage transformers. They are designed to convert solar energy reliably and cost-effectively into grid-compatible energy for infeed into conventional power grids. All individual components of the inverter stations, such as SINVERT PVS inverters and medium-voltage transformers, are technically fully developed, designed for extreme ruggedness electrical and mechanical properties and completely wired and tested. The inverter stations are available in power levels from 1 000 to 2 520 kW with 2, 3 or 4 inverter subunits comprising the PVS500, PVS585, PVS600 and PVS630 inverters (see diagram on page 5). Inverter station SINVERT PVS inverters Medium-voltage transformer Medium-voltage switchgear RE10_00025b Basic interconnection of components in the inverter station in a configuration containing a SINVERT PVS2000, PVS2340, PVS2400 or PVS2520 inverter (each consisting of four SINVERT PVS500, PVS585, PVS600 or PVS630 subunits) 14 SINVERT PVS in power plants © Siemens AG 2012 Intensity of solar irradiation morning noon evening night 1st day 2nd day RE10_00034 3rd day 4th day The inverters integrated in the inverter stations operate with a rotating master according to the master-slave principle. The diagram shows in simplified form that the master moves to the next inverter each day (see left column). In actual fact, the inverter with the fewest operating hours is started as the master on the next day. Master-slave system with SINVERT PVS The SINVERT PVS inverters integrated in the inverter stations operate with a "rotating master" according to the master-slave principle. This is a master-slave system comprising between two and four interconnected inverter subunits. It employs an ingenious process to connect or disconnect inverter subunits, depending on the level of solar irradiation (determined according to the sun's path, cloud conditions, etc.). The master is started up first and operates even when irradiation levels are low. As irradiation levels increase, the next inverter subunit is switched in as a slave when a set switching threshold is exceeded. Depending on the configuration, up to three slaves can be switched in. As irradiation levels drop again, the subunits are disconnected in stages. One advantage of the master-slave principle is that the efficiency factor is higher when irradiation levels (which determine the PV generator output) are low than it would be if only a single inverter were used. In master-slave systems, the "rotating master" function always starts the inverter subunit with the fewest operating hours as the master. In this way, the total operating hours are evenly distributed among all the subunits. ■ Individual components of the inverter stations – SINVERT PVS inverters according to IEC and their components (for further information see Catalog RE10 "Inverters and Components for Photovoltaic Installations") – AC distribution for voltage supply, control and monitoring of the components. – Medium-voltage transformer – Medium-voltage switchgear For technical data on the fully configured inverter stations, the AC distribution, the medium-voltage transformer and the medium-voltage switchgear, please contact your local sales partner: www.siemens.com/sinvert/partner Medium-voltage transformer The medium-voltage transformer transforms the low voltage supplied by the SINVERT PVS photovoltaic inverter into a defined medium voltage of 20 kV, for example, for feeding into the grid. Several medium-voltage transformer brands are available, e.g. the loss-optimized GEAFOL medium-voltage transformer (cast-resin two-tier transformer), which has been specially designed for photovoltaic applications. Detailed information about GEAFOL medium-voltage transformers can be found in the Catalog TV 1 "GEAFOL cast-resin transformers 100 to 16 000 kVA". Medium-voltage switchgear The medium-voltage switchgear is available as an option. It distributes energy and feeds power into the medium-voltage network. Detailed information about medium-voltage switchgear can be found in the Catalog HA 40.2 "Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kV, Gas-Insulated". SINVERT PVS in power plants 15 © Siemens AG 2012 Establishing communication with PVS and system components Communication via Industrial Ethernet and plant monitoring with WinCC Internet Industrial Ethernet SCALANCE S VPN Router DSL-Router WinCC WebNavigator Inverter - Stations 2-n Inverter - Station 1 Inverter SINVERT PVS Inverter SINVERT PVS SINVERT PVS WeatherStation 200 WinCC PC SINVERT PVS ComBox 100 SINVERT PVS ComBox 100 Weather sensors Industrial Ethernet FOC ring Circle control receiver EVU 0% SINVERT PVS ControlBox 300 100 % RE10_00029d Integration of SINVERT PVS inverters into a photovoltaic plant with communication via an Ethernet network, solar PV plant control by means of the SINVERT PVS ControlBox 300, and monitoring with WinCC The inverter stations have an Ethernet interface. If the inverter station is linked to an Ethernet network, this interface permits the exchange of data between the inverter station(s) and the WinCC visualization system on a Microsoft Windows PC. The data server on the ControlBox 300 collects the data from all the inverters. SINVERT PVS ControlBox 300 The purpose of the SINVERT PVS ControlBox 300 is to regulate the active and reactive power of a photovoltaic plant containing SINVERT PVS inverters and to ensure compliance with legal requirements (according to the current amendment of the Renewable Energy Act (EEG), in force since January 2009). Remote access to the WinCC visualization system is also possible over the Internet if the WinCC WebNavigator software has been installed. SINVERT PVS ComBox 100 The SINVERT PVS ComBox 100 communications box interconnects the inverter stations (in linear or ring topologies) with copper or fiber-optic LAN cabling and also connects networkcapable components in the inverter stations, e.g. SINVERT PVS inverters. The ComBox 100 has the following connection options: – 4 x RJ45 ports – 2 x fiber-optic ports, for cable lengths up to 5 km SINVERT PVS ControlBox 300 16 SINVERT PVS in power plants © Siemens AG 2012 Regulation of the PV plant according to BDEW Guideline and the current amendment of the Renewable Energy Act (EEG) by means of SINVERT PVS ControlBox 300 displayed with WinCC The "Generating Plants in the Medium-Voltage Grid" BDEW guideline stipulates this requirement for all systems feeding in at the medium-voltage level. Its primary benefit is that it enables grid operators to limit the output of the plant by remote means in accordance with § 6 of the Renewable Energy Act 2009. The ControlBox 300 offers a wide range of open-loop and closed-loop control functions, e.g.: – Specification of a fixed active power for all individual SINVERT PVS inverters in the PV plant, e.g. setpoint value = 2 MW (active power fixed value) – Specification of a fixed reactive power for all individual SINVERT PVS inverters in the PV plant, e.g. setpoint value = 100 kvar inductive (reactive power fixed value) – Specification of a fixed power factor cos ϕ for all individual SINVERT PVS inverters in the PV plant, e.g. setpoint value = -0.95 – Regulation of the active power for the individual SINVERT PVS inverters in the PV plant as a function of the active power actually measured at the grid infeed – – – – point, to 0%, 30%, 60%, and 100% of the rated active power of the PV plant. (Active power reduction in accordance with § 6 of the Renewable Energy Act Regulation according to Q(U) characteristic Regulation according to Q(t) characteristic Regulation according to P(f) characteristic Ramps for system ramp-up and ramp-down, i.e. continuously approaching the setpoint The SINVERT PVS ControlBox 300 offers the following connection options: – SIMATIC components with digital inputs – SENTRON PAC3200 Power Monitoring Device for measuring actual values at the grid feed-in point – 4 x RJ45 ports – 2 x fiber-optic ports, for cable lengths up to 5 km SINVERT PVS in power plants 17 © Siemens AG 2012 Communication via Industrial Ethernet and plant monitoring by means of SINVERT WebMonitor Internet Industrial Ethernet SCALANCE S VPN Router Inverter - Station 1 DSL-Router SINVERT WebMonitor Inverter - Stations 2-n Inverter SINVERT PVS Inverter SINVERT PVS Client SINVERT PVS WeatherStation 200 SINVERT PVS ComBox 200 SINVERT PVS ComBox 100 Weather sensors Industrial Ethernet FOC ring RE10_00033d Integration of SINVERT PVS inverters into a photovoltaic plant without solar PV plant control with communication via an Ethernet network and monitoring by means of SINVERT WebMonitor In the configuration example shown in the diagram without solar PV plant control and with plant monitoring by means of SINVERT WebMonitor, the required industrial PC is provided in the SINVERT PVS ComBox 200, which must be used in one of the inverter stations instead of a ComBox 100. The ComBox 200 contains the following main components: – 4 x RJ45 ports – 2 x fiber-optic ports, for cable lengths up to 5 km SINVERT PVS ComBox 200 The SINVERT PVS WeatherStation 200 acquires data about the weather at the photovoltaic plant site. This weather data is recorded by sensors connected to the station. The following sensors are included in the scope of supply of the WeatherStation 200: – Insolation – Module temperature – Ambient temperature Additional sensors such as wind speed or rain sensors can be connected. The SINVERT PVS ComBox 200 has the same scope of functions as the ComBox 100, but also provides the capability of transferring data from the SINVERT PVS inverters and from additional network-capable components to the SINVERT WebMonitor web application for monitoring photovoltaic plants. Weather station Using the acquired data, it is possible to perform and transmit extremely precise weather recordings. The target yield of the photovoltaic plant can then be calculated from the recorded weather data. By comparing the actual and target yield, it is possible to make a quick assessment of the plant's operating performance and detect any irregularities very promptly. The SINVERT PVS WeatherStation 200 offers the following connection options: – 6 analog inputs for the sensors – PROFINET communications interface SINVERT PVS ComBox 200 18 SINVERT PVS in power plants © Siemens AG 2012 SINVERT puts sunshine into the grid. Worldwide. Some examples of solar power plants using SINVERT inverters Les Mées (France): 31 MW (2010/2011) Desoto (Florida, USA): 27 MW (2009) Beneixama (Spain): 20 MW (2007) Serpa (Portugal): 11 MW (2007) Shi Lin (China): 10 MW (2010) Dobre Polé (Czech Republic): 4 MW (2010) SINVERT PVS in power plants 19 © Siemens AG 2012 PV plant dimensioning with SINVERT Select For fast and easy dimensioning The key features of SINVERT Select are: ■ The structure and workflow of the SINVERT Select program means that photovoltaic plants containing SINVERT inverters can be dimensioned quickly and simply in just a few steps. ■ The SINVERT Select program can be operated intuitively thanks to the clear structure of the graphical user interface. ■ Extensive database for location selection, containing over 400 locations in more than 30 countries ■ Database containing all the currently available SINVERT inverters ■ Extensive database for module selection, which currently contains over 6 700 different photovoltaic modules available on the market (individual expansion is possible) ■ All the necessary data for dimensioning (locations, SINVERT inverters, and PV modules) is constantly updated. ■ The online update function of the SINVERT Select program means that the latest version of the program is always installed on your computer. ■ Numerous options for specifying the power (specification of area, DC power, and number of modules) ■ Selectable calculation modes (automatic/manual dimensioning, number of photovoltaic modules per string, etc.) ■ Clear display of results of the possible configurations depending on previously selected parameters ■ Project management ■ Creation of reports for presentation of calculation results and printout ■ SINVERT Select also enables reactive power to be accounted for when configuring inverters in accordance with the Technical Guideline "Generating Plants in the Medium-Voltage Grid" of the German Association of Energy and Water Industries (BDEW). ■ Language support: English, German, French, Italian and Spanish SINVERT Select: Proposed solution for dimensioning a photovoltaic plant, including plant details SINVERT Select is a free program which facilitates the dimensioning, analysis and optimization of photovoltaic plants with SINVERT inverters and outputs from a few kilowatts up to the megawatt range. Two different methods can be employed to dimension a photovoltaic plant with SINVERT inverters: ■ ■ With the automatic dimensioning method, the SINVERT Select program first uses the information you enter (string/central inverter, location, photovoltaic module, rated power, etc.) to automatically identify the best possible inverter variant. For this variant, it calculates the performance ratio (PR) and the potential energy yield per annum. Individual configurations can be compared, assessed and optimized on the basis of these parameters. With the manual dimensioning method, you can input one or two SINVERT inverter types in addition to the information about location, photovoltaic module, and rated power. Optionally, their quantity can also be specified. After you have registered, you can download the SINVERT Select program free of charge at: www.siemens.com/sinvert-select 20 PV plant dimensioning with SINVERT Select © Siemens AG 2012 PV plant monitoring For an instant, up-to-date overview and rapid intervention PV plant monitoring with WinCC The key features of WinCC are: ■ A clearly designed user interface provides an instant overview of all key data of the managed plants, subplants and inverters, e.g. states, energy production, and income ■ Graphical representation of the monitored data (see graphic on page 17) ■ Graphics with configurable content for quick visual access to customized displays of received and/or calculated data, e.g. sorted according to day, month, year. ■ Alarms and messages for quick and simple troubleshooting and for ensuring that remedial measures can be quickly taken to minimize loss of earnings ■ Remote monitoring over the Internet with the WinCC/WebNavigator option ■ Acquisition, long-term storage and display of current and historical data ■ Export of archived data to Excel using the DataMonitor option ■ Plant monitoring (e.g. detection and display of faults in the photovoltaic generator through section-by-section measurement of the whole plant) ■ Safeguarding of yield and optimum protection by monitoring the insulation value ■ Messaging services using email and text messaging with the WinCC/AlarmControlCenter option ■ Fault messages can be specifically configured for customized operations management ■ Establishment of as many as 128 user groups, each with up to 128 individual users, and assignment of different authorization levels to the users and/or user groups are possible ■ Representation of monitored plants on a map Visualization and operation of photovoltaic plants with WinCC WinCC (Windows Control Center) is a visualization system which runs on Microsoft Windows. It is used to monitor and control photovoltaic plants in which SINVERT inverters are installed. WinCC provides all the functions required to visualize and operate PV plants, from the PV generator itself to the inverters and grid connection. It can also acquire data (e.g. energy yields) and store it on a long term basis, acquire, store and visualize alarms and messages, and provide data interfaces to external systems. WinCC can run on a Microsoft Windows PC that is connected to the Industrial Ethernet network of the PV plant. Remote access to the WinCC visualization system is also possible over the Internet if the WinCC WebNavigator software has been installed (see graphic on page 16). SINVERT WinCC enables consistently scalable plant configurations – from small PV power plants up to the GW range. In addition, our visualization system can be configured easily and efficiently. The use of a standardized PV library allows customer-specific adaptations to be carried out. WinCC is configured individually according to customer requirements and specific features of the plant. For more information, please contact your regional sales partner. www.siemens.com/sinvert/partner PV plant monitoring 21 © Siemens AG 2012 PV plant monitoring with SINVERT WebMonitor The key features of SINVERT WebMonitor are: SINVERT WebMonitor for monitoring photovoltaic plants ■ Clear user interface layout provides a quick overview of managed plants, subplants and inverters in a tree structure. ■ Overview page (dashboard) and plant page provide instant, up-to-date information about all key aspects of the plants, subplants and inverters, e.g. states, energy production (daily energy, total energy) and income. ■ Fault lists are provided to speed up and simplify troubleshooting and to ensure that remedial measures can be quickly taken to minimize loss of earnings. ■ Graphics with configurable content provide users with quick visual access to customized displays of received and/or calculated data, sorted according to day, month, year and total. ■ Users can configure monitoring settings (e.g. "daily energy deviation") and activate messaging services (e.g. by e-mail) according to individual requirements to receive information about plant status, energy production, income and irregularities. ■ User profiles can be defined so that plants and rights can be individually assigned to users. ■ Display of current and historical data ■ Representation of monitored plants on a map ■ Language support: English, German, French, Italian, Spanish, Czech, Greek and Romanian. SINVERT WebMonitor is a Web application for monitoring photovoltaic plants in which SINVERT inverters are used (see graphic on page 18). It is used for transmitting the states of the photovoltaic plant, for displaying production and income, or optionally for reporting any problems that arise. SINVERT WebMonitor MobileApp With the MobileApp of the SINVERT WebMonitor, it is possible to call up the current and historical data of the selected photovoltaic plant remotely at any time using a smartphone or tablet computer. If you are using SINVERT PVM und SINVERT PVS inverters in your photovoltaic plant and you want to use SINVERT WebMonitor as a plant monitor, you can register and log in at: www.siemens.com/sinvert/webmonitor The SINVERT WebMonitor MobileApp is started by calling the Internet address of the SINVERT WebMonitor from a smartphone or tablet computer. The SINVERT WebMonitor user name is used for the login. SINVERT WebMonitor MobileApp Left: Bar chart indicating daily AC power yield Right: Bar chart indicating annual energy yield 22 PV plant monitoring © Siemens AG 2012 Selection and ordering data for devices and accessories SINVERT PVS 600Series inverters Product type identification Number of masters/slaves Active power output (rated value) Output voltage (rated value) MPP voltage Input voltage (max. permissible) kW V V V Order No. SINVERT PVS inverters (IEC-compliant) Grid frequency 50Hz (rated value) PVS500 1M 500 288 450 ... 750 820 6AG3111-1AH00-3AB0 PVS585 1M 585 340 530 ... 750 820 6AG3111-1AH00-7AB0 PVS600 1M 600 370 570 ... 750 820 6AG3111-1AH00-0AB0 PVS630 1M 630 370 570 ... 750 820 6AG3111-1AH00-8AB0 PVS1000 1M, 1S 1 000 288 450 ... 750 820 6AG3111-1AH10-3AB0 PVS1170 1M, 1S 1 170 340 530 ... 750 820 6AG3111-1AH10-7AB0 PVS1200 1M, 1S 1 200 370 570 ... 750 820 6AG3111-1AH10-0AB0 PVS1260 1M, 1S 1 260 370 570 ... 750 820 6AG3111-1AH10-8AB0 PVS1500 1M, 2S 1 500 288 450 ... 750 820 6AG3111-1AH20-3AB0 PVS1755 1M, 2S 1 755 340 530 ... 750 820 6AG3111-1AH20-7AB0 PVS1800 1M, 2S 1 800 370 570 ... 750 820 6AG3111-1AH20-0AB0 PVS1890 1M, 2S 1 890 370 570 ... 750 820 6AG3111-1AH20-8AB0 PVS2000 1M, 3S 2 000 288 450 ... 750 820 6AG3111-1AH30-3AB0 PVS2340 1M, 3S 2 340 340 530 ... 750 820 6AG3111-1AH30-7AB0 PVS2400 1M, 3S 2 400 370 570 ... 750 820 6AG3111-1AH30-0AB0 PVS2520 1M, 3S 2 520 370 570 ... 750 820 6AG3111-1AH30-8AB0 Grid frequency 60Hz (rated value) PVS500 1M 500 288 450 ... 750 820 6AG3111-2AH00-3AB0 PVS585 1M 585 340 530 ... 750 820 6AG3111-2AH00-7AB0 PVS600 1M 600 370 570 ... 750 820 6AG3111-2AH00-0AB0 PVS630 1M 630 370 570 ... 750 820 6AG3111-2AH00-8AB0 PVS1000 1M, 1S 1 000 288 450 ... 750 820 6AG3111-2AH10-3AB0 PVS1170 1M, 1S 1 170 340 530 ... 750 820 6AG3111-2AH10-7AB0 PVS1200 1M, 1S 1 200 370 570 ... 750 820 6AG3111-2AH10-0AB0 PVS1260 1M, 1S 1 260 370 570 ... 750 820 6AG3111-2AH10-8AB0 PVS1500 1M, 2S 1 500 288 450 ... 750 820 6AG3111-2AH20-3AB0 PVS1755 1M, 2S 1 755 340 530 ... 750 820 6AG3111-2AH20-7AB0 PVS1800 1M, 2S 1 800 370 570 ... 750 820 6AG3111-2AH20-0AB0 PVS1890 1M, 2S 1 890 370 570 ... 750 820 6AG3111-2AH20-8AB0 PVS2000 1M, 3S 2 000 288 450 ... 750 820 6AG3111-2AH30-3AB0 PVS2340 1M, 3S 2 340 340 530 ... 750 820 6AG3111-2AH30-7AB0 PVS2400 1M, 3S 2 400 370 570 ... 750 820 6AG3111-2AH30-0AB0 PVS2520 1M, 3S 2 520 370 570 ... 750 820 6AG3111-2AH30-8AB0 Selection and ordering data 23 © Siemens AG 2012 Options for SINVERT PVS 600Series inverters When ordering an inverter, the order numbers of the respective option are added to the order number of the basic version, i.e. if all four possible options are utilized, five order numbers must be specified for ordering the inverter concerned. The number of slaves of the respective SINVERT PVS 600Series inverters is to be specified by the 11th digit of the order numbers of the inverters and of the associated options. This simplifies the assignment of the options. The number x of slaves is also specified in the identifications of the options in the suffix MxS (M = Master, S = Slaves) For a description of the options see page 10 Product type identification For inverter Order No. PV array grounding positive pole 600Series M PVS500, PVS585, PVS600, PVS630 6AG3911-3FA00-0AH0 PV array grounding positive pole 600Series M1S PVS1000, PVS1170, PVS1200, PVS1260 6AG3911-3FA10-0AH0 PV array grounding positive pole 600Series M2S PVS1500, PVS1755, PVS1800, PVS1890 6AG3911-3FA20-0AH0 PV array grounding positive pole 600Series M3S PVS2000, PVS2340, PVS2400, PVS2520 6AG3911-3FA30-0AH0 PV array grounding negative pole 600Series M PVS500, PVS585, PVS600, PVS630 6AG3911-3FB00-0AH0 PV array grounding negative pole 600Series M1S PVS1000, PVS1170, PVS1200, PVS1260 6AG3911-3FB10-0AH0 PV array grounding negative pole 600Series M2S PVS1500, PVS1755, PVS1800, PVS1890 6AG3911-3FB20-0AH0 PV array grounding negative pole 600Series M3S PVS2000, PVS2340, PVS2400, PVS2520 6AG3911-3FB30-0AH0 1000 V option 600Series M PVS500, PVS585, PVS600, PVS630 6AG3911-3GA00-0AH0 1000 V option 600Series M1S PVS1000, PVS1170, PVS1200, PVS1260 6AG3911-3GA10-0AH0 1000 V option 600Series M2S PVS1500, PVS1755, PVS1800, PVS1890 6AG3911-3GA20-0AH0 1000 V option 600Series M3S PVS2000, PVS2340, PVS2400, PVS2520 6AG3911-3GA30-0AH0 Symmetry monitoring 600Series M PVS500, PVS585, PVS600, PVS630 6AG3911-3EA00-0AH0 Symmetry monitoring 600Series M1S PVS1000, PVS1170, PVS1200, PVS1260 6AG3911-3EA10-0AH0 Symmetry monitoring 600Series M2S PVS1500, PVS1755, PVS1800, PVS1890 6AG3911-3EA20-0AH0 Symmetry monitoring 600Series M3S PVS2000, PVS2340, PVS2400, PVS2520 6AG3911-3EA30-0AH0 Cabinet heating 600Series M PVS500, PVS585, PVS600, PVS630 6AH3911-3HA00-1AH0 Cabinet heating 600Series M1S PVS1000, PVS1170, PVS1200, PVS1260 6AH3911-3HA10-1AH0 Cabinet heating 600Series M2S PVS1500, PVS1755, PVS1800, PVS1890 6AH3911-3HA20-1AH0 Cabinet heating 600Series M3S PVS2000, PVS2340, PVS2400, PVS2520 6AH3911-3HA30-1AH0 Options for SINVERT PVS 600Series inverters PV array grounding 1 000 V option Symmetry monitoring Cabinet heating 24 Selection and ordering data © Siemens AG 2012 System components, accessories, spare parts for SINVERT PVS 600Series inverters Product type identification Number of inputs Type of fuse protection at input Input current per input (maximum) Isolating device at the output Surge arrester Order No. A SINVERT PVS CombinerBoxes Array junction box CombinerBox 108 8 Fuse holder 10 -- -- 6AG3611-3FF21-1AA0 CombinerBox 108 8 Fuse holder 10 -- ✓ 6AG3611-3FF21-1BA0 CombinerBox 108 8 Fuse holder 10 ✓ -- 6AG3611-3FF21-1CA0 CombinerBox 108 8 Fuse holder 10 ✓ ✓ 6AG3611-3FF21-1DA0 CombinerBox 120 20 Fuse holder 13 -- -- 6AG3611-3FL21-1AA0 CombinerBox 120 20 Fuse holder 13 ✓ -- 6AG3611-3FL21-1CA0 CombinerBox 124 24 Fuse holder 13 -- -- 6AG3611-3FM21-1AA0 CombinerBox 124 24 Fuse holder 13 ✓ -- 6AG3611-3FM21-1CA0 Fuse holder 125 -- -- 6AG3611-3FD01-1AA0 Generator junction box CombinerBox 204 ✓ included -- not included Size 4 Operating class Operational current (rated value) Operational voltage (rated value) Power loss A V W Order No. Fuses for SINVERT PVS CombinerBox LV HRC fuse kit Size 1 gPV 80 1 000 23 3NE1 220-4 Size 1 gPV 100 1 000 25 3NE1 221-4 Size 1 gPV 125 1 000 28 3NE1 222-4 Size 1 gPV 160 1 000 Product type identification 3NE1 224-4 Order No. SINVERT PVS weather station WeatherStation 200 6AG3611-3BA00-2AA0 SINVERT PVS ComBox ComBox 100 6AG3611-3AB00-1AA0 ComBox 200 6AG3611-3AB00-2AA0 SINVERT PVS ControlBox ControlBox 300 6AG3611-3AA00-3AA0 SparesKit for SINVERT PVS SINVERT PVS SparesKit 100 6AG3911-3JA00-1AG0 SINVERT PVS SparesKit 200 6AG3911-3JA00-2AG0 Selection and ordering data 25 © Siemens AG 2012 Service & Support Unique range of complete services for the entire life cycle rt up p o S e n O n li ld Fie vice r Se Service Programs Modernization Services The range of services offered by Siemens Industry Automation and Drive Technologies includes comprehensive Service and Support for a very broad range of users. To accompany our products and systems, we offer integrated and structured services that provide valuable support in every phase of the lifecycle of your photovoltaic plant – from planning, implementation and commissioning to maintenance and modernization. Online Support Training Tec S u p hni c a l por t Sp are Pa r ts Technical Consulting Engineering Support Optimization Services Our Service & Support accompanies you in all matters concerning our products and systems for photovoltaic plants. We provide direct on-site support through all phases of the lifecycle of your photovoltaic plants. An experienced team of specialists with a pool of expertise is at your side to provide active support. Regular training courses and intensive contact with our employees – even across continents – ensure reliable service in a wide variety of areas. Technical assistance / hotline The comprehensive online information platform supports you in all aspects of our Service & Support at any time and from any location in the world. For example, you can find technical product information here. Competent consulting in technical questions covering a wide range of customer-oriented services for all our products and systems. www.siemens.com/sinvert/ support technical-assistance@ siemens.com www.siemens.com/sinvert/ technical-assistance SINVERT Hotline (in English and German): Tel.: +49 (911) 895-5900 26 Service & Support © Siemens AG 2012 Training Extend your competitive edge – with practical know-how directly from the manufacturer. Familiarize yourself with the technical details and advantages of SINVERT solar inverters so that you can work out the best plant configuration for any situation. www.siemens.com/sinvert/ training Advantages at a glance: Service programs Our service programs comprise selected packages of services for photovoltaic plants. The individual services of a service program can be flexibly adapted and used separately. ■ ■ ■ ■ Comprehensive service from a single source, fewer interfaces and greater expertise ■ Reliability of service due to assured response times and spare part delivery times ■ Minimized downtimes ■ Optimized service costs due to a tailored scope of services Spare parts service – Spare parts – SparesKits Service calls – Commissioning – On-site service – Maintenance Service contracts – SparesContract – WarrantyExtension – MaintenanceContract – FullServiceContract Service & Support 27 © Siemens AG 2012 Tailored program of services for SINVERT PVS Spare parts service Service calls Security of supply of necessary spares - without contractual obligations Service specialists assure plant availability The spare parts service for SINVERT PVS offers you two ways of ordering spares: – On-demand spare parts delivery – SparesKits Three different types of service call are available: – Commissioning – On-site service – Maintenance On-demand spare parts delivery Service calls for SINVERT PVS inverters Commissioning Spare parts service for SINVERT PVS: On-demand spare parts delivery The relevant spare part can if necessary be ordered directly from your regional contact person. Spare parts can be delivered to anywhere in the world, by express courier if requested. The following work is carried out during a commissioning callout: – Checking the correct connection of the inverters – Setting up the inverters – Testing and documentation – Professional contact persons on site There is a large selection of individual spare parts available for SINVERT PVS. Further information can be requested from your regional contact person. On-site service SINVERT PVS SparesKits If troubleshooting via remote access by the Siemens SINVERT hotline fails to resolve a problem, our specialists can visit your site on request to offer you advice and assistance. Maintenance You can ask us to dispatch specialists to your site to carry out preventive maintenance on a date of your choice (in this case, materials will be supplied by our engineer). Spare parts service for SINVERT PVS: SparesKit on-site Kits stored on site containing spares for the most important components ensure even greater security of supply: – SINVERT PVS SparesKit 100 recommended for photovoltaic plants containing up to 10 inverter subunits – SINVERT PVS SparesKit 200 recommended for PV plants containing more than 10 inverter subunits – Order numbers see page 25 28 Service & Support © Siemens AG 2012 Service contracts SINVERT PVS service contracts can be concluded within the first 24 months following commissioning of the installation. Depending on the contract type, a contract term of 10, 15 or 20 years can be selected. 24h Service contracts for SINVERT PVS inverters New: 24/7 hotline for contract customers The sales contact person in the respective region must be contacted for specific orders: www.siemens.com/sinvert/partner SINVERT PVS service contracts safeguard investments. Customers can choose between a number of contract types to suit their individual requirements. Contract variants and contents SparesContract Warranty Extension Maintenance Contract FullService Contract Benefits level 100 200 Spare parts availability over term of contract 9 9 300 100 100 100 9 9 9 9 Spare parts -- Contractually assured delivery time for spare parts -- 9 9 9 -- 9 -- 3 WD1) -- -- -- Routine maintenance: Maintenance parts -- 9 9 -- 9 9 Routine maintenance: Engineer -- -- -- -- 9 9 Site service calls: Engineer -- -- -- 9 -- 9 -- -- -- WD1) Contractually assured response time for technical support on site -- -- 3 Contractually assured response time for remote support -- -- -- -- -- 1 WD1) Assured repair time -- -- -- -- -- 3 WD1) Telephone support 24/7 9 9 9 9 9 9 Reimbursement for loss of earnings -- -- 9 -- -- 9 Agreed contract periods in years 15, 20 10, 15, 20 10, 15, 20 10, 20 10, 15, 20 10, 15, 20 9 yes -- no 1) WD = working day Service & Support 29 © Siemens AG 2012 SINVERT PVS SparesContract – Spares stocking as a low-cost alternative spare part requirements. Any spare parts required shall be taken from the spares kit and replacement parts then ordered free of charge from Siemens. All repair and maintenance work shall be carried out by the customer's own trained service personnel. In the event that on-site troubleshooting support by a Siemens specialist is required, a service call must be ordered separately. SINVERT PVS WarrantyExtension – Extends the period of the standard warranty SINVERT PVS SparesContract For large-scale photovoltaic plants operated by customers who employ their own on-site maintenance personnel, it might make more sense economically to conclude a spares contract which would assure availability of spare parts over the entire contract term. Three benefits levels SINVERT PVS Spares Contracts are available with three benefits levels (100, 200 and 300) and with contract terms of 10, 15 or 20 years to suit the individual requirements of the customer (a contract term of 15 or 20 years must be selected in combination with benefits level 100). ■ The following applies to all three benefits levels: – Assured availability of spare parts over the entire term of the contract – A 24-hour hotline has been set up to provide technical support by our Technical Assistance team and to arrange service calls. Troubleshooting support by means of remote access will be offered where necessary. ■ Additional services with benefits levels 200 and 300: – All spares and routine maintenance parts which are needed on site over the contract term shall be provided free of charge by Siemens. – Siemens will supply the required parts free of charge on receipt of notification that routine maintenance is due. ■ Additional services with benefits level 300: – Contractually assured spare parts delivery time of 3 working days – Contractually assured response time of 3 working days for provision of on-site support by a Siemens engineer – Reimbursement of loss of earnings in the event that Siemens cannot respond within the assured times. A basic condition for conclusion of a SINVERT PVS SparesContract is that the customer purchases a spares kit to cover initial 30 Service & Support SINVERT PVS WarrantyExtension service contract The SINVERT PVS WarrantyExtension option can be selected as a quick and simple means of extending the standard 5-year manufacturer warranty for the SINVERT PVS inverters. The customer can choose to extend the warranty to 10 or 20 years depending on individual requirements. This service contract is intended for customers who wish to call on support from Siemens specialists when servicing is required. The SINVERT PVS WarrantyExtension offers: ■ Spare parts – The availability of spare parts is assured over the entire contract term. – All spare parts which are needed to repair defects during service calls over the contract term shall be provided free of charge by Siemens. ■ Telephone support – A 24-hour hotline has been set up to provide technical support by our Technical Assistance team and to arrange service calls. ■ Field support – After Siemens has received a fault notification, Siemens specialists will rectify the fault via remote access or will dispatch service personnel free of charge to the site in question if this is deemed necessary. © Siemens AG 2012 SINVERT PVS MaintenanceContract – Routine maintenance by Siemens The SINVERT PVS FullServiceContract can be selected with a contract term of 10, 15 or 20 years depending on the individual requirements of the customer. SINVERT PVS MaintenanceContract SINVERT PVS FullServiceContract The SINVERT PVS MaintenanceContract ensures that routine maintenance is provided by Siemens specialists. This service contract is intended for customers who want to use preventive maintenance by Siemens specialists as a means of ensuring that their plant remains fully functional at all times. The SINVERT PVS FullServiceContract offers: ■ Spare parts – The availability of spare parts is assured over the entire contract term. – All routine maintenance parts required to carry out all the prescribed routine maintenance as well as any spare parts needed to repair defects during service callouts will be supplied free of charge by Siemens over the term of the contract. The SINVERT PVS MaintenanceContract can be selected with a contract term of 10, 15 or 20 years depending on the individual requirements of the customer. The SINVERT PVS MaintenanceContract offers: ■ Spare parts – The availability of spare parts is assured over the entire contract term. – All spare parts required to perform routine maintenance at the prescribed routine maintenance intervals over the term of the contract will be provided free of charge by Siemens. ■ Telephone support – A 24-hour hotline has been set up to provide technical support by our Technical Assistance team and to arrange service calls. – A response time of one working day for providing troubleshooting support via hotline/remote access is guaranteed. ■ Telephone support – A 24-hour hotline has been set up to provide technical support by our Technical Assistance team and to arrange service calls. Troubleshooting support by means of remote access will be offered where necessary. ■ On-site service – Siemens shall bear all the costs of service engineer callouts to site required to carry out the prescribed routine maintenance or to eliminate faults during the term of the contract. ■ ■ Field support – Siemens shall bear all the costs of service engineer callouts to site required to carry out the prescribed routine maintenance during the term of the contract. The SINVERT PVS FullServiceContract ensures the following in particular: – The inverter shall be repaired within three working days of receipt of notification of a fault from the customer – Any loss of earnings shall be reimbursed in the event that Siemens cannot respond within the guaranteed times SINVERT PVS FullServiceContract – All-inclusive package for all-round service The all-inclusive SINVERT PVS FullServiceContract is intended for customers who rely on the support of Siemens specialists in every case and who wish to enjoy the benefits of all-round service for their plant. A basic condition for conclusion of a SINVERT PVS Full Service Contract is that the customer purchases a spares kit to cover initial spare part requirements. Any spare parts required shall be taken from the spares kit and replacement parts then o rdered free of charge from Siemens. Service & Support 31 © Siemens AG 2012 Get more information: Technical Assistance Phone: +49 (911) 895-5900 Fax: +49 (911) 895-5907 E-mail: technical-assistance@siemens.com Siemens AG Industry Sector Control Components and Systems Engineering Postfach 2355 90713 FÜRTH GERMANY www.siemens.com/sinvert Subject to change without notice Order No.: E86060-T1818-A101-A2-7600 MP.R3.XT.0000.00.2.07 / Dispo 46371 BR 0512 3. WÜ 32 En Printed in Germany © Siemens AG 2012 The information provided in this brochure contains descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. Availability and technical specifications are subject to change without notice. All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : I IA CE MK&ST Create Date : 2012:05:24 15:05:30+02:00 Keywords : Renewable energy, Photovoltaics, SINVERT PVS inverters Modify Date : 2012:06:06 09:40:55+02:00 Has XFA : No Language : en XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Producer : Acrobat Distiller 9.5.1 (Windows) Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2012:06:06 09:40:55+02:00 Format : application/pdf Description : Photovoltaics Subject : Renewable energy, Photovoltaics, SINVERT PVS inverters Title : SINVERT PVS 600Series Central Inverters and Components for Photovoltaic Power Plants Creator : I IA CE MK&ST Document ID : uuid:aa93053a-32b9-4542-9dec-eb96012b4e3f Instance ID : uuid:5d1da12e-0662-45eb-bb3d-b2172c584756 Page Layout : SinglePage Page Mode : UseOutlines Page Count : 32 Signing Date : 2012:06:06 09:40:54+02:00 Signing Authority : ARE Acrobat Product v8.0 P23 0002337 Annotation Usage Rights : Create, Delete, Modify, Copy, Import, ExportEXIF Metadata provided by EXIF.tools