Siemens Welding System St Pcs 7 Users Manual SIMATIC Process Control
ST PCS 7 to the manual 999d0011-6fa0-44e9-b5d4-cf09cd146107
2015-02-05
: Siemens Siemens-Welding-System-St-Pcs-7-Users-Manual-410671 siemens-welding-system-st-pcs-7-users-manual-410671 siemens pdf
Open the PDF directly: View PDF .
Page Count: 344
Download | |
Open PDF In Browser | View PDF |
Catalog ST PCS 7 · November 2007 © Siemens AG 2007 simatic SIMATIC PCS 7 Process Control System © Siemens AG 2007 Related catalogs SIMATIC Add-ons for the SIMATIC PCS 7 Process Control System ST PCS 7.1 Training for Automation and Industrial Solutions Order no.: E86060-K6850-E101-B8 (in German) Only PDF: (E86060-K4678-A121-A6-7600) SIMATIC ST PCS 7.2 Catalog CA 01 SIMATIC ST 70 A&D Mall Migration solutions with the SIMATIC PCS 7 Process Control System Order no.: E86060-K4678-A131-A3-7600 Products for Totally Integrated Automation and Micro Automation Order no.: E86060-K4670-A101-B1-7600 E86060-K4670-A151-A3-7600 (News) SIMATIC HMI Human Machine Interface Systems ST 80 Industrial Communication IK PI TELEPERM M PLT 112 AS 488/TM Automation Systems Only PDF: (E86060-W3812-A100-A3-7600) Field Instruments for Process Automation Order no.: E86060-K6201-A101-A9-7600 the Offline Mall of Automation and Drives Order no.: E86060-D4001-A100-C6 (CD-ROM) E86060-D4001-A500-C6 (DVD) Internet: www.siemens.com/automation/mall Order no.: E86060-K4680-A101-B5-7600 Industrial Communication for Automation and Drives Order no.: E86060-K6710-A101-B5-7600 E86060-K6710-A121-A2-7600 (News) ITC FI 01 I T C © Siemens AG 2007 SIMATIC PCS 7 Process Control System Version 7.0 Catalog ST PCS 7 · October 2007 Introduction System-neutral components 2 Starter systems 3 Engineering system 4 Operator system 5 Batch automation 6 SIMATIC Route Control 7 Asset Management 8 Communication 9 Supersedes: Catalog ST PCS 7 · March 2007 The products contained in this catalog can also be found in the e-Catalog CA 01 Order No.: E86060-D4001-A110-C6-7600 (CD-ROM) E86060-D4001-A510-C6-7600 (DVD) Please contact your local Siemens branch © Siemens AG 2007 The products and systems described in this catalog are manufactured/distributed under application of a certified quality management system in accordance with DIN EN ISO 9001 (Certified Registration No. 1323-QM). The certificate is recognized by all IQNet countries. s 1 Automation systems 10 Process I/O 11 IT world 12 Migration to SIMATIC PCS 7 13 Ordering data for previous version SIMATIC PCS 7 V6.1 14 Update/upgrade packages 15 Appendix 16 © Siemens AG 2007 Siemens Automation and Drives. Welcome More than 70,000 people aiming for the same goal: increasing your competitiveness. That's Siemens Automation and Drives. We offer you a comprehensive portfolio for sustained success in your sector, whether you're talking automation engineering, drives or electrical installation systems. Totally Integrated Automation (TIA) and Totally Integrated Power (TIP) form the core of our offering. TIA and TIP are the basis of our integrated range of products and systems for the manufacturing and process industries as well as building automation. This portfolio is rounded off by innovative services over the entire life cycle of your plants. Learn for yourself the potential our products and systems offer. And discover how you can permanently increase your productivity with us. Your regional Siemens contact can provide more information. He or she will be glad to help. 1/2 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Siemens ST PCS 7 · November 2007 1/3 © Siemens AG 2007 Sharpen your competitive edge. Totally Integrated Automation With Totally Integrated Automation (TIA), Siemens is the only manufacturer to offer an integrated range of products and systems for automation in all sectors - from incoming goods to outgoing goods, from the field level through the production control level to connection with the corporate management level. On the basis of TIA, we implement solutions that are perfectly tailored to your specific requirements and are characterized by a unique level of integration. This integration not only ensures significant reductions in interface costs but also guarantees the highest level of transparency across all levels. ERP Enterprise Resource Planning Ethernet Management Level MES Manufacturing Execution Systems Ethernet Operations Level SIMATIC PCS 7 Process Control (DCS) Industrial Software for Maintenance Design and Engineering Installation and Commissioning Modernization and Upgrade Operation Control Level SINUMERIK Computer Numeric Control PROFINET Field Level Industrial Ethernet PROFIBUS PROFIBUS PA AS-Interface Process Instrumentation Totally Integrated Automation 1/4 SIMOTION Motion Control System Siemens ST PCS 7 · November 2007 HART SIMATIC Sensors © Siemens AG 2007 It goes without saying that you profit from Totally Integrated Automation during the entire life cycle of your plants - from the first planning steps, through operation, right up to modernization. Consistent integration in the further development of our products and systems guarantees a high degree of investment security here. Totally Integrated Automation makes a crucial contribution towards optimizing everything that happens in the plant and thus creates the conditions for a significant increase in productivity. SIMATIC IT SIMATIC WinCC SCADA System SIMATIC NET Industrial Communication SIMATIC Controllers Modular/Embedded/PC-based SIMATIC HMI Human Machine Interface Safety Integrated SIRIUS Industrial Controls SENTRON Switching Devices SIMOCODE pro Motor Management System SIMATIC Distributed I/O SINAMICS Drive Systems AS-Interface Totally Integrated Power KNX/EIB GAMMA instabus Siemens ST PCS 7 · November 2007 1/5 © Siemens AG 2007 Integrated energy distribution from a single source. Totally Integrated Power Totally Integrated Power (TIP) brings together all the components of electrical energy distribution into an integrated whole. Thus TIP provides the answer to growing market demands in the planning, construction and use of utility buildings and industrial buildings. On the basis of TIP, we offer integrated solutions for energy distribution, from medium voltage to the power outlet. Totally Integrated Power is based here on integration in planning and configuring as well as on perfectly matched products and systems. Communication HMI Process/production automation Load management U UI I cos o P o cos PW W PROCESS FIELD BUS Products and systems £ 110 kV Planning and configuration 1/6 Siemens ST PCS 7 · November 2007 Graphs Prognoses © Siemens AG 2007 Totally Integrated Power offers communication and software modules for connecting the energy distribution systems to industrial automation and building automation. This enables the implementation of significant savings potential. Maintenance Substation Distribution Maintenance task Message/ error management Selective protection Protocols Power quality DATE: EMPLOYEE Cost center Building automation COST CENTER PAY PERIOD BEGINNING PAY PERIOD ENDING DATE SUN MON TUE WED THUR FRI SAT SUN TOTAL IN OUT IN OUT OVERTIME TOTAL HOURS DATE SUN MON TUE WED THUR FRI SAT SUN TOTAL IN OUT IN OUT OVERTIME TOTAL HOURS Hall 1 Distribution 3 Infeed II Air conditioning system checkup Replacing circuit breaker contacts Replacing meters DATE SUN MON TUE WED THUR FRI SAT SUN TOTAL IN OUT IN OUT OVERTIME TOTAL HOURS CODES V=VACATION H=HOLIDAY S=SICK REGULAR HOLIDAY OTHER OVER THE HOURS TIME & ONE-HALF SICK VACATION instabus EIB Siemens ST PCS 7 · November 2007 1/7 © Siemens AG 2007 Protecting the environment and resources. Environmental sustainability Environmental protection will continue to grow in importance as a result of progressive urbanization and global population growth. These global mega-trends make the careful and sustainable handling of natural resources a central challenge. We are convinced that every individual - and especially every company - has an ecological responsibility. At Siemens Automation and Drives, we stand by this conviction. Our high environmental protection goals are part of our strict environmental management. We investigate the possible effects of our products and systems on the environment right back at the development stage. We concern ourselves, for example, with the question of how to reduce power consumption in plant operation - and we offer appropriate solutions, such as our energy-saving motors that cut power consumption in industrial manufacturing by up to 40% thanks to their high efficiency levels. Our products and systems comply with the EC Directive RoHS (Restriction of Hazardous Substances). All the relevant Siemens AG sites are, of course, certified in accordance with DIN EN ISO 14001. Our commitment goes well beyond compliance with the relevant directives and legislation: we are an active driving force behind environmental protection, through further development of environmental management systems, for example, and we are involved in professional associations such as the German Electrical and Electronic Manufacturers Association (ZVEI). 1/8 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Siemens ST PCS 7 · November 2007 1/9 © Siemens AG 2007 Introduction System architecture SIMATIC PCS 7 V7.0 ■ Overview SIMATIC PCS 7 Takes you beyond the limits! INTERNET Web Client Management information/ Manufacturing Execution System SAP SIMATIC IT Office LAN (Ethernet) Security Modules OS / Batch / Route Control Clients OS Single Station SIMATIC PCS 7 BOX Web Server/ OpenPCS 7 INTERNET OS-LAN, single/redundant Network printer Engineering Station Asset Management/ Maintenance station Ethernet OS / Route Control Server Batch/archive server Industrial Ethernet, single/redundant SIMATIC PCS 7 AS RTX Fault-tolerant automation systems ET 200M MTA Zone 1 ET 200M Ex I/O, HART DP/PA link ET 200M F modules ET 200iSP Ex operator terminal PROFIBUS PA PROFIBUS DP DP/AS-Interface link PROFIBUS DP DP/FF Link DP/PA link PROFIBUS PA Y link DP/PA link with redundant DP/PA couplers Active Field Splitter ET 200M with CP 341 Modbus, serial connection ET 200M Standard and F modules ET 200M single/redundant Weighing systems Zone 2 FF-H1 Safety-related automation systems PROFIBUS DP ET 200M Standard automation systems PROFIBUS PA COx, NOx PROFIBUS DP DP/PA link ET 200pro ET 200S ET 200iSP HART Integrated Drives ET 200S PROFIBUS PA Active Field Distributors SIMATIC PCS 7 system configuration Totally Integrated Automation with SIMATIC PCS 7 The SIMATIC PCS 7 process control system is a significant component of Totally Integrated Automation (TIA), the unique basis offered by Siemens for uniform and customized automation in all sectors of the production, process and hybrid industries. Using TIA, Siemens is the only company able to offer uniform automation technology on one single platform for all applications of process automation, starting with input logistics, covering production or primary processes as well as downstream (secondary) processes, up to output logistics. This is suitable for optimization of all operating sequences of an entire company, i.e. from the ERP (Enterprise Resource Planning) level and MES (Management Execution System) level to the control level, right down to the field level. Integrated in a holistic automation solution for a production site, automation of the primary processes is the prime task of SIMATIC PCS 7. On the other hand, secondary processes (e.g. filling, packaging) or input/output logistics (e.g. raw material distribution, storage) are frequently implemented using the PLCbased or PC-based components of SIMATIC. The advantages of Totally Integrated Automation, in particular the uniform data management, communication and configuration, are already evident during planning and engineering, but also during installation and commissioning, everyday operation as well as maintenance, repairs and modernization. 1/10 Siemens ST PCS 7 · November 2007 Uniform data management means that all software components access a common database. Within a project, inputs and modifications are therefore only necessary at one point. This reduces the work required, and simultaneously avoids potential faults. Once symbolic identifications have been introduced, they are understood by every software component. Data consistency is also guaranteed even if several persons are working simultaneously on a project. Parameters defined in the engineering system can be transferred beyond the network limits down to sensors, actuators or drives in the field. Uniform communication from the corporate management level down to the field level is based on internationally recognized standards such as Industrial Ethernet or PROFIBUS, and also supports the global flow of information via the Internet. Since the hardware and software components involved also use these communications mechanisms, connections are extremely easy to configure, also cross-system or over different networks. The use of an engineering system with a uniform and matched range of tools minimizes the configuration overhead. The engineering tools for the application software, the hardware components and the communications functions can be called from a central project manager (SIMATIC Manager). This is also the basic application for creation, management, saving and documentation of a project. Compatibility of further developments is guaranteed within TIA. This also guarantees that the company’s investments have a secure future, and allows the company to modernize and expand the plants throughout the complete lifecycle. © Siemens AG 2007 Introduction System architecture SIMATIC PCS 7 V7.0 ■ Benefits With its pioneering design, modular and open architecture based on state-of-the-art SIMATIC technology, consistent application of industrial standards, and the I&C functionality paired with high-performance, the SIMATIC PCS 7 process control system allows cost-effective implementation and economical operation of I&C plants in all phases of their lifecycle and with consideration of all aspects: from planning, engineering, commissioning, training, through operation, maintenance and repair, up to expansion and refurbishment. In the process, SIMATIC PCS 7 combines high-performance and reliability with simple and safe operation and maximum convenience. You primarily profit from Totally Integrated Automation with the SIMATIC PCS 7 process control system through: 7 Calculable development, implementation and lifecycle costs 7 Minimization of engineering overhead 7 Facilities for process optimization 7 Adaptability to changing requirements 7 Advantages resulting from the use of standard SIMATIC components, such as: - Low hardware and engineering costs - Proven quality and stability - Simple, fast definition and selection of system components - Low costs for spare parts - Short delivery times for spare parts and expansion components - Global availability - Savings in logistics, maintenance and training costs ■ Function A consistent and homogeneous overall system SIMATIC PCS 7 is a modern process control system that can be used alone or in combination with other systems, e.g. SIMATIC, SIMOTION or drive systems, as a consistent and homogenous overall system. Its popularity is increasing along with the demand for seamlessly integrated universal automation engineering solutions, which is determined by sustained competition and price pressure, the demand for increasingly flexible production plants and the need for increased productivity. Against the background of ever-increasing complexity, in particular due to the merging of automation engineering with information technology, horizontal and vertical integrated system platforms are being increasingly accepted in comparison to automation solutions with so-called "best-in-class products". Efficient control of material transport Asset management for I&C equipment (diagnostics, preventive maintenance and repairs) 7 Direct interface with the IT world 7 Advanced security concept for safeguarding the I&C system. 7 7 Flexibility and scalability As a result of its modular architecture based on selected hardware and software components from the standard SIMATIC range, SIMATIC PCS 7 can be applied effectively in small and large plants alike. It allows easy expansion or system modification to enable customers to meet the changing production requirements of their facility. SIMATIC PCS 7 is scalable from a small single system consisting of approx. 160 process tags (motors, valves, PID controllers), such as might be used for a laboratory system or a test center, up to a distributed multi-user system with client/server architecture and approx. 60,000 process tags, such as might be used for automation of a very large production plant or for groups of connected facilities. SIMATIC PCS 7 thus covers all sizes of plant - and if the plant grows, SIMATIC PCS 7 grows with it! Open for the future SIMATIC PCS 7 is based on modular hardware and software components, which are perfectly matched to one another due to their conformance with TIA. These components can be expanded and innovated seamlessly and with little effort and are open for the future via long-term stable interfaces. This makes long-term protection of customer investments possible, despite the fast pace of innovation and short product cycles. SIMATIC PCS 7 consistently applies new, powerful technologies together with internationally established industrial standards such as IEC, XML, PROFIBUS, Ethernet Gigabit technology, TCP/IP, OPC, ISA-88 or ISA-95, just to mention a few. Openness with SIMATIC PCS 7 covers all levels, and equally applies to automation systems and process I/Os as to industrial communications networks, operator systems or engineering systems. Not just system architecture and communication are characterized by openness. This is a feature also evident in the programming and data transfer interfaces for user programs as well as in the import and export functions for graphics, text and data, e.g. from the CAD/CAE world. SIMATIC PCS 7 can therefore also be combined with components from other vendors, and integrated in existing infrastructures. Totally Integrated Automation with SIMATIC PCS 7 combines consistent data management, communication and configuration with outstanding system properties and high performance. This guarantees that the typical demands placed on a process control system are comprehensively satisfied, and that you are perfectly equipped for future requirements: 7 Simple and reliable process control 7 User-friendly operation and visualization, also using the Internet 7 Powerful, fast and consistent system-wide engineering 7 System-wide online modifications 7 System openness at all levels 7 Flexibility and scalability 7 Redundancy at all levels 7 Safety-related automation solutions 7 Extensive fieldbus integration 7 Flexible solutions for batch processes Siemens ST PCS 7 · November 2007 1/11 © Siemens AG 2007 Introduction 1/12 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 System-neutral components 2/2 System documentation 2/4 Administration 2/6 Operating system 2/7 SIMATIC PCS 7 Industrial Workstation Introduction Basic hardware Multi-VGA graphics cards Operator panels/monitors Special configurations 2/7 2/10 2/16 2/17 2/18 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 System-neutral components 2 System documentation ■ Overview S7 Manual Collection The system documentation of the SIMATIC PCS 7 process control system is an integral component of the SIMATIC PCS 7 system software. It is available in two versions: • As online help (HTML help) • As electronic documentation in Acrobat Reader format (PDF) The 3-language documentation (German, English, French) provides both beginners and experienced users with valuable information on all aspects of the process control system. The range extends from the system introduction, covers initial steps and cross-system topics, up to a description of individual system components. With the "Getting Started" documentation you can gain initial practical experience using example projects. SIMATIC PCS 7 Programming Instructions Driver Blocks Programming Instructions for creating drive blocks and with the title "SIMATIC PCS 7 Programming Instructions Driver Blocks" can be ordered separately. These Programming Instructions help the advanced SIMATIC PCS 7 user to create system-conform driver blocks, which can be placed like standard blocks on system plans and automatically parameterized and interconnected in HW-Config. 2/2 Siemens ST PCS 7 · November 2007 As a supplement to the SIMATIC PCS 7 system documentation, the S7 Manual Collection provides comprehensive information on all system components offered in the context of SIMATIC S7. This multi-language collection of electronic manuals on DVD contains documentation on the following in addition to the SIMATIC PCS 7 system documentation: • SIMATIC S7-200/300/400, • SIMATIC C7, • LOGO! logic module, • SIMATIC DP, • SIMATIC PC, • SIMATIC programming devices, • STEP 7, • engineering software, • runtime software, • SIMATIC PCS 7, • SIMATIC HMI and • SIMATIC NET. The electronic manuals of the S7 Manual Collection are usually in 5 languages (German, English, French, Italian, Spanish), those of the integral SIMATIC PCS 7 system documentation mostly in 3 languages (German, English, French). For the migration of existing plants, you may also require detailed information on the system components of TELEPERM M or SIMATIC S5. TELEPERM M Manual Collection The TELEPERM M Manual Collection comprises TELEPERM M manuals in 2 languages (German, English) on CD. S5 Manual Collection An S5 Manual Collection in 2 languages (German, English) on CD, which contains all electronic manuals concerning SIMATIC S5, rounds off the range of available information. © Siemens AG 2007 System-neutral components System documentation ■ Selection and Ordering Data SIMATIC PCS 7 Programming Instructions Driver Blocks V7.0 for SIMATIC PCS 7 V6.1 and V7.0 Electronic documentation on CD, in 2 languages (German, English) Type of delivery: CD, certificate of license, terms and conditions ■ More information Order No 6ES7 653-1XD07-8YX8 SIMATIC S7 manuals S7 Manual Collection Electronic manuals on DVD, in 5 languages (German, English, French, Italian, Spanish) 6ES7 998-8XC01-8YE0 D) S7 Manual Collection maintenance service for 1 year Type of delivery: Current DVD "S7 Manual Collection" and the three subsequent updates 6ES7 998-8XC01-8YE2 D) 6DL5 900-8AX03-8YX8 D) TELEPERM M migration manuals TELEPERM M Manual Collection Electronic manuals on CD, in 2 languages (German, English) SIMATIC S5 manuals S5 Manual Collection Electronic manuals on CD, in 2 languages (German, English) 6ES5 998-7WE02 D) Subject to export regulations: AL: N, ECCN: 5D992B1 D) The "SIMATIC Guide Manuals" on the Internet directs you straight to the complete range of technical documentation available for SIMATIC products and systems in German, English, French, Italian, Spanish and Chinese. If other languages are available, you can also find them there. You can select individual documents from this range for viewing or downloading. Additional information is available in the Internet under: http://www.siemens.com/simatic-docu Siemens ST PCS 7 · November 2007 2/3 2 © Siemens AG 2007 System-neutral components 2 Administration ■ Overview ■ Function SIMATIC Logon Admin Tool Using the SIMATIC Logon Admin Tool it is possible to assign the roles defined in the SIMATIC PCS 7 applications (e.g. Automation License Manager and SIMATIC BATCH) to the Windows users/user groups. Administrators with the necessary Windows administrator privileges can also use the SIMATIC Logon Admin Tool to edit Windows users and user groups. SIMATIC Logon Service The login dialog of the SIMATIC Logon Service is activated when an application is started which is managed by SIMATIC Logon. The user receives his specific privileges after making the login, password and domain entries. The SIMATIC Logon Service dialog for logoff, user change or password edit can be called in the applications. SIMATIC Electronic Signature Central user management, access control and electronic signature SIMATIC Logon is a central user administration function with access control based on Windows 2000/XP and Windows Server 2003 for: • System components of SIMATIC PCS 7 • Non-system components linked via an interface It can be used to fulfill the validation requirements of 21 CFR Part 11. An electronic signature function can also be used in conjunction with SIMATIC Logon. SIMATIC Logon Upgrade All previous versions can be upgraded to the current version. ■ Design The optional chipcard reader can be used for access control in addition to the keyboard. SIMATIC Logon additionally supports logon devices which can be operated with a Microsoft device driver for the respective operating system (e.g. logon devices on a USB interface). It is also possible to connect logon devices via a separately created device-specific drive. The number of SIMATIC Logon licenses required depends on the number of clients/single stations that access applications for which SIMATIC Logon is used for access protection. SIMATIC Logon was developed for the SIMATIC PCS 7 process control system but can also be used together with other SIMATIC products in the context of Totally Integrated Automation (TIA), e.g. with SIMATIC WinCC. A requirement for working together is that user groups have already been created in the partner applications, or can be defined. SIMATIC Logon is already integrated in the system software of the SIMATIC PCS 7 V7.0 process control system. Separate licenses are not required in this context. 2/4 Siemens ST PCS 7 · November 2007 The SIMATIC Electronic Signature means that operations cannot be performed until enabled by previously assigned Windows users/user groups. Users/user groups are assigned to the operations in the respective application. At the moment this function is implemented as a system function only on SIMATIC BATCH. However, the Electronic Signature can be used on any products in the specific applications. The software products listed here under "Selection and ordering data" are only relevant to use in the TIA environment. © Siemens AG 2007 System-neutral components Administration ■ Selection and Ordering Data ■ Options Order No. only for TIA applications Access security by means of chipcard reader SIMATIC Logon V1.4 Single license for 1 installation 7 languages (German, English, French, Spanish, Italian, Chinese, Japanese), executes with Windows 2000 Professional SP4, Windows 2000 Server, Windows XP Professional SP2 or Windows Server 2003 SP1 and R2 Engineering software and electronic documentation on CD Type of delivery: CD, license key disk, emergency key disk, certificate of license, terms and conditions 6ES7 658-7BX41-2YA0 SIMATIC Logon Upgrade to V1.4 Single license for 1 installation 7 languages (German, English, French, Spanish, Italian, Chinese, Japanese), executes with Windows 2000 Professional SP4, Windows 2000 Server, Windows XP Professional SP2 or Windows Server 2003 SP1 and R2 Engineering software and electronic documentation on CD Type of delivery: CD, license key disk, emergency key disk, certificate of license, terms and conditions 6ES7 658-7BX41-2YE0 A chipcard reader can be used to check a person’s authorization to access and operate a single station or a client. This method of access security uses the chipcard as a "key" to the operator terminals. Operations are only allowed when the card is actually inserted in the reader. The unmistakable identification of access rights is required in particular for plants which have to meet validation requirements. The chipcard reader is compliant with EN 55022 Class B and EN 50082-1 standards. The reader is available with an USB interface for the connection of the operator station. Note: The reader with USB interface can only be used with SIMATIC Logon. Options Chipcard reader USB Chipcard reader with USB interface, driver software and operating instructions 6ES7 652-0XX02-1XC0 Chipcard Chipcard for chipcard reader; 1 card required per user; package with 10 chipcards 6ES7 652-0XX05-1XD1 B) B) Subject to export regulations: AL: N, ECCN: EAR99H Siemens ST PCS 7 · November 2007 2/5 2 © Siemens AG 2007 System-neutral components 2 Operating system ■ Overview Operating system upgrade When existing SIMATIC PCS 7 systems are updated to Version 7.0, it may also be necessary to upgrade the operating system. If you replace your existing hardware by new SIMATIC PCS 7 Industrial Workstations from this catalog when carrying out an upgrade, the Windows XP Professional or Windows Server 2003 operating systems including 5 CAL (Client Access Licenses) required for SIMATIC PCS 7 V7.0 are already included in the scope of delivery. You can also purchase individual operating systems or additional Client Access Licenses (CAL) from Fujitsu Siemens Computers GmbH. Contact address for quotations and orders Fujitsu Siemens Computers GmbH Mr. Dominikus Besserer Phone: +49 821 804-2434 Fax: +49 821 804-2972 E-mail: dominikus.besserer@fujitsu-siemens.com 2/6 Siemens ST PCS 7 · November 2007 Note: Please note when ordering that SIMATIC PCS 7 V7.0 is operated together with Windows XP Professional Service Pack 2 and Windows Server 2003 Service Pack 2. Release 2 of Windows Server 2003 has not been approved for SIMATIC PCS 7 V7.0. © Siemens AG 2007 System-neutral components SIMATIC PCS 7 Industrial Workstation Introduction ■ Overview ■ Design Microsoft Windows operating system The multi-language Microsoft Windows XP Professional or Server 2003 operating system as well as the SIMATIC PCS 7 system software for OS or ES/OS are preinstalled on the SIMATIC PCS 7 Industrial Workstation. The Microsoft Server 2003 operating system is supplied with 5 CALs (Client Access Licenses). You can purchase further CALs from Fujitsu Siemens Computers GmbH (see page 2/6). Monitors and multi-VGA operation The core component of the SIMATIC PCS 7 Industrial Workstation is a SIMATIC industrial PC without keyboard or monitor. This basic hardware can be combined with the industrial LCD monitors recommended in the Section "HMI devices/monitors" for SIMATIC PCS 7 in the Catalog "PC-based Automation" to suit the operating environment and the customer’s requirements. Using a multi-VGA graphics card, the visualization of a project/ subproject when engineering or a plant/unit in process operation can be divided among up to 4 process monitors per operator station with application of different views (see page 2/16). We offer a range of modern, powerful SIMATIC PCS 7 Industrial Workstations for the systems positioned in the SIMATIC PCS 7 system architecture above the controller level, e.g. for engineering, operation and monitoring (also via Internet/intranet), batch control, route control, asset management or IT applications etc. These are optimized for use as single station, client or server, and can be expanded specific to the system. This is supported in the SIMATIC PCS 7 workstations designed as clients by additional hardware versions: • SIMATIC PCS 7 OS Client RACK PC 547B WXP with multiVGA graphics card "2 Screens" and • SIMATIC PCS 7 OS Client RACK PC 547B WXP with multiVGA graphics card "4 Screens" Clients and single stations with a standard graphic interface module for controlling a process monitor can also be expanded by a multi-VGA graphics card "2 Screens" or "4 Screens" (see page 2/16). Siemens ST PCS 7 · November 2007 2/7 2 © Siemens AG 2007 System-neutral components SIMATIC PCS 7 Industrial Workstation 2 Introduction ■ Options Notes on the use of other basic hardware and non-SIMATIC software Siemens guarantees the compatibility of hardware and software for system configurations based on components in this catalog. software components, the support provided for elimination thereof is not free of charge. The system test confirms that the system software of the SIMATIC PCS 7 process control system can be run on the SIMATIC PCS 7 Industrial Workstations offered in this catalog. Despite comprehensive tests, it cannot be excluded that the function of a SIMATIC PCS 7 system could be disturbed or interfered with as a result of additional non-SIMATIC software, i.e. software which has not been explicitly approved for SIMATIC PCS 7. The licenses for plant bus communication via Industrial Ethernet, i.e. for Basic Communication Ethernet (BCE) and CP 1613 communication are bound to the SIMATIC PCS 7 Industrial Workstations. Depending on the selected type of communication, the SIMATIC PCS 7 Industrial Workstations for single stations and servers are delivered either with a BCE license or CP 1613 license. If you are not using SIMATIC PCS 7 V7.0 on SIMATIC PCS 7 Industrial Workstations, you additionally require a SIMATIC PCS 7 BCE V7.0 license (Order No. 6ES7 650-1CD072YB5) for all single stations or servers which are connected to the plant bus via a standard network card and not via a CP 1613. If you use hardware other than the basic hardware offered in this catalog, or additional non-SIMATIC software, this is at your own risk. If compatibility problems arise as a result of these hardware/ Requirements on the configuration of the SIMATIC PCS 7 basic hardware Depending on the application of the SIMATIC PCS 7 basic hardware, the following hardware requirements must be observed. Minimum configuration of basic hardware depending on target system Target systems Engineering station (ES) ● Engineering station with server operating system ● OS single station ● OS server ● OS client ● Central archive server ● PCS 7 Web server ● Maintenance station (MS) ● BATCH single station ● BATCH server ● BATCH client ● Common OS/BATCH client ● Route Control (RC) single station ● Route Control server ● Route Control client ● Common OS/BATCH/Route Control single station Technical specifications of basic hardware ● Processor, clock Intel Pentium IV, 2 GHz Intel Pentium IV, 2 GHz Intel Pentium IV, 2 GHz Main memory (RAM) 2 GB 1 GB 512 MB • Storage capacity 120 GB 120 GB 80 GB • Size of C partition 20 GB 20 GB 20 GB Network adapter, communications interfaces RJ45 connection (Fast Ether- RJ45 connection (Fast Ethnet) for terminal bus (OS-LAN) ernet) for terminal bus (OS-LAN) Hard disk Optical drive 2/8 Siemens ST PCS 7 · November 2007 RJ45 connection (Fast Ethernet) for terminal bus (OS-LAN) CP1613 A2 or RJ45 network card (Fast Ethernet) with BCE for plant bus (ES, as well as BATCH/OS/RC on one PC) CP1613 or RJ45 network -card (Fast Ethernet) with BCE for plant bus (ES, MS, OS single station/server and RC single station/server) DVD-ROM DVD-ROM DVD-ROM © Siemens AG 2007 System-neutral components SIMATIC PCS 7 Industrial Workstation Introduction Recommended configuration of basic hardware depending on target system Target systems Engineering station with server operating system ● OS single station ● OS server ● OS client ● Central archive server ● PCS 7 Web server ● Maintenance station (MS) ● BATCH single station ● BATCH server ● BATCH client ● Common OS/BATCH client ● Route Control (RC) single station ● Route Control server ● Route Control client ● Common OS/BATCH/Route Control single station ● Engineering station with server operating system Technical specifications of basic hardware PC type ● SIMATIC Rack PC 547B CPU • Processor, clock Intel Core 2 Duo E6600 / 2 x 2.4 GHz Intel Core 2 Duo E6600 / 2 x 2.4 GHz • Front Side Bus (FSB) 1066 MHz 1066 MHz • Second Level Cache 4 MB 4 MB Main memory (RAM) 2 GB 1 GB • Number, storage capacity, type 2 x 250 GB SATA in RAID 1 network for server and ES/OS single stations; 1 x 250 GB SATA for client systems 1 x 250 GB SATA • Size of C partition 50 GB 50 GB Network adapter, communications interfaces RJ45 connection (Gigabit Ethernet) for terminal bus (OS-LAN) on board RJ45 connection (Gigabit Ethernet) for terminal bus (OS-LAN) on board CP1613 A2 or RJ45 Ethernet network card 10/100/1000 Mbit/s with BCE for plant bus (ES, MS, OS single station/ server and RC single station/server) -- DVD writer (DVD±RW) for engineering station; DVD-ROM for all other target systems DVD-ROM Hard disks Optical drive Additional recommendations/limitations • It is generally of advantage for the system performance if the technical specifications of the basic hardware, e.g. clock, main memory or hard disk, are above the recommended values listed in the table. This particularly applies to multiproject engineering. • A requirement for integration of PC-based SIMATIC PCS 7 basic hardware into the PC diagnostics of the SIMATIC PCS 7 asset management is the SIMATIC PC DiagMonitor software. This belongs to the scope of delivery of SIMATIC PCS 7 Industrial Workstations and SIMATIC PCS 7 BOX RTX/416 and cannot be executed on other systems. • For long-term archiving with large quantity frameworks, we recommend the PCS 7 Premium server from the Catalog ST PCS 7.1 (Add-ons for the SIMATIC PCS 7 process control system) as the central archive server. However, the PCS 7 Premium server cannot be integrated into the PC diagnostics of the SIMATIC PCS 7 asset management. • For increased data availability on the central archive server, we recommend a RAID hard disk system (at least RAID 1). Siemens ST PCS 7 · November 2007 2/9 2 © Siemens AG 2007 System-neutral components SIMATIC PCS 7 Industrial Workstation 2 Basic hardware ■ Overview ■ Application Specially optimized versions are available for operation as single stations, servers or clients. The operating system and the following ES/OS software of the SIMATIC PCS 7 process control system are already preinstalled when delivered: • Single station: PCS 7 Engineering Software for AS/OS (including OS Runtime software) • Server: PCS 7 OS Software Server • Client: PCS 7 OS Software Client You only need the corresponding licenses in order to use the preinstalled SIMATIC PCS 7 software. The SIMATIC PCS 7 Industrial Workstations are based on a SIMATIC Rack PC of type 547B which features powerful, innovative Intel PC architecture of 19" design. They are certified by the CE marking for use in offices and industrial environments, and comply with the specific requirements of process control technology. 2/10 Siemens ST PCS 7 · November 2007 Note: Please note the standard installation if you use the SIMATIC PCS 7 Industrial Workstations within the SIMATIC PCS 7 process control system for other tasks, e.g. as basic hardware for SIMATIC BATCH, SIMATIC Route Control, StoragePlus, Central Archive Server or PCS 7 Web Server. You can then extend or reject the existing SIMATIC PCS 7 installation, and restore it for the operating system using the restore DVD. The CP 1613 communication integrated in the IE version of the SIMATIC PCS 7 Workstation for single stations and servers is a combination of CP 1613 communications processor and S7-1613 communications software. When using fault-tolerant automation systems, the SIMATIC PCS 7 Workstation requires the S7-REDCONNECT software instead of the S7-1613 communications software. The S7-REDCONNECT Upgrade is suitable for upgrading the communications software (for ordering data, see page 9/29). © Siemens AG 2007 System-neutral components SIMATIC PCS 7 Industrial Workstation Basic hardware ■ Design 2 slots for 5.25" drives Operational display Hard disk access Fan/temperature status AC power supply 2 x USB 3.5" diskette drive Interfaces for keyboard, mouse, 4 x USB 2.0, COM1, LPT1, VGA, Audio, Gigabit Ethernet Power switch Optical drive Extension slots: 4 x PCI, 2 x PCIe x1, 1 x PCIe x16 The SIMATIC PCS 7 Industrial Workstations of type Rack PC 547B have a painted all-metal housing of 19" rack design which is particularly protected against dust by a filter and pressurized ventilation. This mechanically and electromechanically rugged housing has a service-friendly design. The SIMATIC PCS 7 Industrial Workstations of type Rack PC 547B can be positioned and installed horizontally or vertically. High-grade components with high MTBF values and monitoring functions for the inner housing temperature, fan and program execution permit reliable 24-hour continuous operation at ambient temperatures between 5 and 40 °C. The SIMATIC PCS 7 Industrial Workstations of type Rack PC 547B have the following features: • Motherboard with future-oriented Intel architecture for modern Core 2 Duo processors, based on Intel 945G Express chipset • Powerful AGP graphics with Dynamic Video Memory, sound (Line In, Line Out, Mic.) and 10/100/1000 Mbit/s Ethernet RJ45 port integrated onboard • PCI-Express technology (1 PCIe x16 and 2 PCIe x1 slots) • 6 slots for drives: - At the front: three 5.25" slots (1 occupied by DVD-ROM/ DVD-RW) and - one 3.5" slot (occupied by diskette drive) - Inside: two 3.5" slots (occupied by 1 hard disk on the client, and 2 hard disks on the server and ES/OS single station) • Increased system availability through RAID 1 with 2 SATA hard disks and NCQ technology (Native Command Queuing) on the server and ES/OS single station • Second serial interface (for server) available (COM2) • Total of 6 USB 2.0 interfaces (4 at rear, 2 at front) • High electromagnetic compatibility (CE-certified for industrial and office environments) • Dust protection by means of pressurized ventilation in conjunction with a front fan and a dust filter • PC front complies with IP30 degree of protection when the front door is closed • Front door can be locked to prevent unauthorized access to swap media, control elements and interfaces located at the front • Easy and fast installation and maintenance of PC components: access to the front drives through a hinged front door; only 3 screws to open the device • 3 LEDs on the front of the PC visualize the operating status: - Power (switched on) - HD (hard disk access) - Status (fan and temperature monitoring) • Suitable for easy mounting with telescopic rails • Easy to remove fixing bracket with handles • Card hold-down device to secure PC modules during transportation and to protect them from vibration and shock • Power supply unit with temperature-controlled fan • Power connector lock for the power supply cable • SIMATIC PC DiagMonitor diagnostics software for monitoring program execution (watchdog), temperature, fan speed, hard disk status and system failure (heartbeat); including operating hours counter • Can be integrated into the system diagnostics of the SIMATIC PCS 7 asset management by means of SIMATIC PC DiagMonitor Restore DVD The operating system and SIMATIC PCS 7 software are preinstalled on the basic devices. Two restore DVDs are supplied for quickly restoring the delivered status if required. • Restore DVD 1 only contains the operating system with default settings for optimum PCS 7 operation • Restore DVD 2 contains a full installation (operating system plus ES/OS software including SQL server) Siemens ST PCS 7 · November 2007 2/11 2 © Siemens AG 2007 System-neutral components SIMATIC PCS 7 Industrial Workstation 2 Basic hardware ■ Technical specifications ■ Technical specifications SIMATIC PCS 7 Industrial Workstation (single station/server/client) (cont.) Interchangeable drives Design and equipment features • Diskette drive 3.5" diskette drive 1.44 MB Design 19" rack, 4 HU, for horizontal and vertical installation, prepared for easy mounting with telescopic rails, 19" fixing bracket with handle, easy to remove • DVD drive in ES/OS single station Degree of protection to EN 60529 IP30 with front door closed; IP20 at rear Motherboard FSC D2156-S21 Chipset Intel 945G Express DVD writer (DVD±RW) 5.25" ATAPI Read: • DVD-ROM: single layer 16x, dual layer 12x • DVD-R/+R: single layer 16x, dual layer 7x • DVD-RW/+RW 13x • CD-ROM/CD-R 48x, CD-RW 40x Write: • DVD+R 18x, DVD+RW 8x, DVD-R 18x, DVD-RW 6x • DVD+R9 (DL) 8x, DVD-R DL 8x • CD-R 48x, CD-RW 32x • DVD drive in server/client DVD-ROM 5.25" ATAPI Read: • DVD-ROM: single layer 16x, dual layer 8x • DVD+R/RW, DVD-R/RW 8x, DVD-RAM 2x • CD-ROM, CD-R 32x, CD-RW 20x Graphics card Intel GMA950 graphics controller (on board), 2D and 3D engine integrated in chipset, up to 2048 x 1536 pixels with 75 Hz image refresh rate • Graphics memory Dynamic video memory technology (up to 224 MB) • Resolutions. frequencies, colors • Up to 800 x 600 at 120 Hz, 32 bit colors • Up to 1280 x 1024 at 100 Hz, 32 bit colors • Up to 2048 x 1536 at 75 Hz, 16 bit colors Mouse Optical mouse CPU • Processor base LGA 775 • Processor / clock Intel Core 2 Duo E6600 / 2 x 2.4 GHz • Front Side Bus (FSB) 1066 MHz • Second Level Cache 4 MB Main memory (SDRAM) • Type Dual channel DDR2-667 SDRAM (PC2-5300) • Maximum configuration 4 memory bases in total (expandable to 4 GB) • Standard configuration Single station/server: 2 GB (2 x 1 GB) Client: 1 GB (2 x 512 MB) Motherboard slots 4 x PCI (max. 265 mm long) 2 x PCIe x1 1 x PCIe x16 Slots for drives • On the front 1 x 3.5" (occupied by diskette drive) 3 x 5.25" (1 occupied by DVD-ROM/DVD±RW) • On the inside 2 x 3.5" for hard disk drives (2 occupied with server/single station; 1 occupied with client) RAID controller Intel ICH7R with Intel Storage Manager software (onboard) Interface modules / interfaces • Storage volumes / features 250 GB / 3.5" SATA, 8 MB cache, 7200 rpm, NCQ • Plant bus interface module (single station/server), alternatives • Single station/server SATA-RAID 1 (mirror) with 2 hard disks - RACK PC 547B BCE Ethernet network card RJ45 (PCI) 10/100/1000 Mbit/s • Client 1 SATA hard disk - RACK PC 547B IE CP 1613 A2 communications processor RAID controller • OS-LAN interface module Hard disks 2/12 Siemens ST PCS 7 · November 2007 10/100/1000 Mbit/s Ethernet (RJ45) on board, Broadcom BCM5751 controller • USB 6 x USB 2.0, 4 x at rear and 2 x at front, high current in each case • Serial Server: 1 x COM1 and 1 x COM2 (each V.24), 9-contact Sub-D connector Single station/client: 1 x COM1 (V.24), 9-contact Sub-D connector • Parallel 1 x LPT1 (25-pin, EPP and ECP) • Audio 1 x Line In; 1 x Micro In; 1 x Line Out (2 x 0.5 W/8 Ω); Realtek ALC262 Audio Codec • VGA 1 x Sub-D socket, 15-contact • Keyboard 1 x PS/2 • Mouse 1 x PS/2 © Siemens AG 2007 System-neutral components SIMATIC PCS 7 Industrial Workstation Basic hardware ■ Technical specifications (cont.) ■ Technical specifications (cont.) Operating systems and diagnostics software Climatic conditions ES/OS single station/client Microsoft Windows XP Professional MUI, 6 languages, selectable: German, English, French, Italian, Spanish, Chinese Temperature Tested according to IEC 60068-2-2, IEC 60068-2-1, IEC 60068-2-14 Server Microsoft Windows Server 2003 (standard edition) MUI, 6 languages, selectable: German, English, French, Italian, Spanish, Chinese • Operation System-tested SIMATIC industrial software SIMATIC PC DiagMonitor +5 ... +40 °C (no DVD writer operation), +5 ... +35 °C (without limitation) CPU up to 65 W power loss Gradient: max. 10 °C/h, no condensation • Storage/transport -20 ... +60 °C Gradient: max. 20 °C/h, no condensation Relative humidity Tested according to IEC 60068-2-78, IEC 60068-2-30 • Operation 5 ... 80% at 25 °C (no condensation) Gradient: max. 10 °C/h, no condensation • Storage/transport 5 ... 95% at 25 °C (no condensation) Gradient: max. 20 °C/h, no condensation Monitoring/diagnostics functions Watchdog • Monitoring of program execution • Monitoring time adjustable in the software Temperature Violation of permissible operating temperature Fans Speed monitoring for: • Front fan • Processor fan • Power supply fan Displays Front LEDs • Power (device switched on) • HD (access to hard disk) • Status (fan/temperature monitoring) Mechanical environmental conditions Vibrations Tested according to IEC 60068-2-6, 10 cycles • Operation 20 ... 58 Hz, amplitude 0.015 mm; 58 ... 200 Hz: 2 m/s² Note: No mechanical interferences are tolerable when writing with CD/DVD writers. Safety Protection class Protection class I compliant with IEC 61140 Safety directives EN 60950-1; UL60950; CSA C22.2 No. 60950-00 • Storage/transport 5 ... 8.51 Hz, amplitude 3.5 mm; 8.51 ... 500 Hz: 9.8 m/s² Shock Tested according to IEC 60068-2-27 < 45 dB (A) to DIN 45635 • Operation Half sine: 9.8 m/s², 20 ms, 100 shocks per axis Note: No mechanical interferences are tolerable when writing with CD/DVD writers. • Storage/transport Half sine: 250 m/s², 6 ms, 1000 shocks per axis Noise level Operation Electromagnetic compatibility (EMC) Emitted interference (AC) EN 55022 Class B; FCC Class A EN 61000-3-2 Class D, EN 61000-3-3 Immunity to conducted interference on the supply lines ± 2 kV (to IEC 61000-4-4, burst) ± 1 kV (to IEC 61000-4-5, symmetrical surge) ± 2 kV (to IEC 61000-4-5, unsymmetrical surge) Immunity to interference on signal lines ± 2 kV (to IEC 61000-4-4, burst, length > 3 m) ± 2 kV (to IEC 61000-4-5, symmetrical surge, length > 30 m) Immunity to static discharge ± 4 kV, contact discharge (to IEC 61000-4-2) ± 8 kV, atmospheric discharge (to IEC 61000-4-2) Immunity to high-frequency irradiation 1 V/m, 2 to 2.7 GHz 10 V/m, 80 MHz to 1 GHz and 1.4 to 2 GHz, 80% AM (to IEC 61000-4-3) 10 V, 10 kHz to 80 MHz (to IEC 61000-4-6) Magnetic field 100 A/m, 50 Hz/60 Hz (to IEC 61000-4-8) Approvals CE living accommodation (emitted interference) EN 61000-6-3:2001 CE industrial areas (noise immunity) EN 61000-6-2:2005 cULus 60950-1 Siemens ST PCS 7 · November 2007 2/13 2 © Siemens AG 2007 System-neutral components SIMATIC PCS 7 Industrial Workstation 2 Basic hardware ■ Technical specifications ■ Selection and Ordering Data (cont.) Power supply Nominal supply voltage 100 to 240 V AC, wide-range (90 to 264 V AC) Frequency 50 ... 60 Hz (minimum 47 to maximum 63 Hz, sinusoidal) Short-term voltage dip 16 ms at 0.85 of nominal supply voltage (max. 10 events per hour; recovery time min. 1 s) Power consumption (with 210 W secondary) 310 W (approx 68% efficiency) AC input current Continuous current up to 7 A (up to 30 A for 5 ms during startup) Max. current output • +3.3 V: 24 A • +5 V: 26 A (total power for +3.3 V and +5 V max. 190 W) • +12 V: 15 A • -12 V: 0.2 A • +5 Vaux: 2 A Dimensions and weights Overall dimensions in mm (W x H x D) 433.5 x 176.5 x 445.5 Weight 16 ... 23 kg ■ Selection and Ordering Data Order No. SIMATIC PCS 7 Industrial Workstation, single station version SIMATIC PC in 19" rack, without monitor, keyboard and printer; Core 2 Duo E6600 2.4 GHz processor, 2 GB RAM (2 x 1 GB), sound, SATA-RAID 1 with 2 hard disks of 250 GB, graphics controller on board with dynamic video memory, DVD writer DVD±RW IDE, 3.5" diskette drive, optical mouse, Ethernet 10/100/1000 Mbit/s (RJ45) on board for connection to OS-LAN; SIMATIC PC DiagMonitor diagnostics software and 2 restore DVDs; SIMATIC PCS 7 ES/OS software preinstalled 6ES7 650-0NF07-0YX0 • SIMATIC PCS 7 ES/OS 547B IE WXP Connection to plant bus with CP 1613 A2 communications processor 6ES7 650-0NF07-0YX1 2/14 Windows Server 2003 MUI operating system (German, English, French, Italian, Spanish, Chinese) • SIMATIC PCS 7 OS Server 547B BCE SRV03 Connection to plant bus with Ethernet network card RJ45 (PCI) 10/100/1000 Mbit/s and Basic Communication Ethernet (BCE) for up to 8 automation systems (not fault-tolerant systems) 6ES7 650-0NH07-0YX0 D) • SIMATIC PCS 7 OS Server 547B IE SRV03 Connection to plant bus with CP 1613 A2 communications processor 6ES7 650-0NH07-0YX1 D) SIMATIC PCS 7 Industrial Workstation, client version SIMATIC PC in 19" rack, without monitor, keyboard and printer; Core 2 Duo E6600 2.4 GHz processor, 1 GB RAM (2 x 512 MB), SATA hard disk of 250 GB, graphics controller on board with dynamic video memory, DVDROM IDE, 3.5" diskette drive, optical mouse, Ethernet 10/100/1000 Mbit/s (RJ45) on board for connection to OS-LAN; SIMATIC PC DiagMonitor diagnostics software and 2 restore DVDs; SIMATIC PCS 7 OS software for client preinstalled Windows XP Professional MUI operating system (German, English, French, Italian, Spanish, Chinese) • SIMATIC PCS 7 ES/OS 547B BCE WXP Connection to plant bus with Ethernet network card RJ45 (PCI) 10/100/1000 Mbit/s and Basic Communication Ethernet (BCE) for up to 8 automation systems (not fault-tolerant systems) Order No. SIMATIC PCS 7 Industrial Workstation, server version SIMATIC PC in 19" rack, without monitor, keyboard and printer; Core 2 Duo E6600 2.4 GHz processor, 2 GB RAM (2 x 1 GB), sound, SATA-RAID 1 with 2 hard disks of 250 GB, graphics controller on board with dynamic video memory, DVD-ROM IDE, 3.5" diskette drive, optical mouse, Ethernet 10/100/1000 Mbit/s (RJ45) on board for connection to OS-LAN; SIMATIC PC DiagMonitor diagnostics software and 2 restore DVDs; SIMATIC PCS 7 OS software for server preinstalled D) Windows XP Professional MUI operating system (German, English, French, Italian, Spanish, Chinese) • SIMATIC PCS 7 OS Client 547B WXP Siemens ST PCS 7 · November 2007 D) - without multi-VGA graphics card 6ES7 650-0NG07-0YX0 D) - with Multi-VGA graphics card "2 Screens" 6ES7 650-0NG07-0YA0 D) - with Multi-VGA graphics card "4 Screens" 6ES7 650-0NG07-0YB0 D) D) Subject to export regulations: AL: N, ECCN: 5D992B1 © Siemens AG 2007 System-neutral components SIMATIC PCS 7 Industrial Workstation Basic hardware ■ Selection and Ordering Data ■ Accessories Order No. Additional and expansion components Keyboards Memory modules for expanding the main memory The SIMATIC PCS 7 Industrial Workstations are delivered without a keyboard. The SIMATIC PC keyboard with USB connection, for example, is suitable for process operation with SIMATIC PCS 7. • 512 MB memory expansion for SIMATIC Rack PC 547B (1 x 512 MB), DDR2-667 SDRAM 6ES7 648-2AF30-0HA0 B) • 1 GB memory expansion for SIMATIC Rack PC 547B (2 x 512 MB), DDR2-667 SDRAM, kit for dual-channel technology 6ES7 648-2AF40-0HB0 B) • 2 GB memory expansion for SIMATIC Rack PC 547B (2 x 1 GB), DDR2-667 SDRAM, kit for dual-channel technology 6ES7 648-2AF50-0HB0 B) SIMATIC PC keyboard (USB connection) • International key assignment 6ES7 648-0CB00-0YA0 The SIMATIC PC keyboard is a standard MF2 keyboard with 105 keys, without additional special functions. It combines the convenience of an office keyboard with the EMC of an industrial device. Standards/approvals: UL 1950, CSA C22.2 No. 950, FCC Part 15, subpart B, class B, VDE-GS (EN 60950/ZHI/618), CE, C-TICK-Mark (Australia). Power supply cable for Rack PC The SIMATIC PCS 7 systems are delivered as standard with a "European power cable". This can be used in Germany, France, Spain, Netherlands, Belgium, Sweden, Austria and Finland. The country-specific versions listed in the Ordering data are required for other countries. The following picture shows the appearance of the power supply plugs: Tower kit for SIMATIC PCS 7 Industrial Workstations based on Rack PC 547B and IL 43 • Tower kit for conversion of a Rack PC into an industrial Tower PC 6ES7 648-1AA00-0XC0 3-m power cable for Rack PC 1) • For Great Britain 6ES7 900-0BA00-0XA0 • For Switzerland 6ES7 900-0CA00-0XA0 • For USA 6ES7 900-0DA00-0XA0 • For Italy 6ES7 900-0EA00-0XA0 • For China 6ES7 900-0FA00-0XA0 SIMATIC NET S7-REDCONNECT Upgrade For communication with faulttolerant AS systems, see page 9/29 B) Subject to export regulations: AL: N, ECCN: EAR99H 1) Country-specific power supply cables for Rack PC Tower Kit A Tower Kit for converting a SIMATIC PCS 7 Industrial Workstation of Rack PC design into an industrial Tower PC can be ordered as an option. The Tower Kit is suitable for SIMATIC PCS 7 Industrial Workstations based on the Rack PC types 547B and IL 43. The PCS 7 systems are delivered as standard with a "European power cable". The country-specific versions listed above are required for some countries. Siemens ST PCS 7 · November 2007 2/15 2 © Siemens AG 2007 System-neutral components SIMATIC PCS 7 Industrial Workstation 2 Multi-VGA graphics cards ■ Overview ■ Technical specifications Multi-VGA graphics cards Memory 32 MB DDRAM per output • Graphics card "2 Screens" 2 x 32 MB • Graphics card "4 Screens" 4 x 32 MB Clock 360 MHz integrated RAMDAC Max. analog resolution per channel 2048 x 1536 at 24 bpp and 85 Hz Max. digital resolution per channel 1280 x 1024 Electromagnetic compatibility (EMC) • Emitted interference EN 55022 Class B • Noise immunity EN 50082 Slot requirement 1 PCI slot ■ Selection and Ordering Data The SIMATIC PCS 7 industrial workstations are supplied as standard with a graphics interface module for controlling one process monitor. The multi-VGA graphics cards "2 Screens" and "4 Screens" are available for multi-channel mode with 2 or up to 4 process monitors. Using a multi-VGA graphics card, the visualization of a project/subproject when engineering or a plant/unit in process operation can be divided among up to 4 process monitors per operator station with application of different views. These project/plant sections can all be operated using just one keyboard and one mouse. Compared to single-channel mode, it is thus possible to enormously improve the efficiency, convenience and ergonomics of engineering and process control. 2/16 Siemens ST PCS 7 · November 2007 Order No. Multi-VGA Graphics Card "2 Screens" for operating 2 process monitors on 1 station Type of delivery: Dual graphics card, driver CD, manual, 1 dual DVI cable for 2 digital outputs, 2 adapters for VGA outputs 6ES7 652-0XX03-1XE0 B) Multi-VGA Graphics Card "4 Screens" for operating 4 process monitors on 1 station Type of delivery: Quad graphics card, driver CD, manual, 2 dual DVI cables for 4 digital outputs, 4 adapters for VGA outputs 6ES7 652-0XX03-1XE1 B) B) Subject to export regulations: AL: N, ECCN: EAR99H © Siemens AG 2007 System-neutral components SIMATIC PCS 7 Industrial Workstation Operator panels/monitors ■ Overview ■ Technical specifications Operating devices Monitor SCD 19101-D In addition to the mouse and SIMATIC PC keyboard described as operating devices in the Section "Basic hardware", you can find further devices such as fingerprint mouse, trackball or Ex-PC operator panel in the Catalog ST PCS 7.1 (Add-ons for the SIMATIC PCS 7 process control system). Screen 19" (48 cm) TFT color monitor, 1280 x 1024 pixels, 16 million colors Line frequency 50 ... 97 kHz Image refresh rate 30 ... 100 Hz Process monitors Power supply 110/230 V AC Dimensions (WxHxD) in mm 465 x 444 x 91 (depth of stand 240) Degree of protection IP20 Weight Approx. 10 kg Detailed technical data can be found in • Catalog ST PC "PC-based Automation" or • the Mall/CA 01 at "Automation systems - Monitors, printers and input devices for industry" ■ Selection and Ordering Data We recommend the SCD 19101-D industrial monitor (LCD color monitor) for the SIMATIC PCS 7 process control system. In addition, industrial LCD monitors with IP65 degree of protection (front) are available for installation in desks, control cabinets or 19" racks. These are available from: • the Catalog ST PC "PC-based Automation" or • the A&D Mall/CA 01 under "Automation Systems – PC-based Automation - Expansion Components - Industrial LCD Monitors" ■ Benefits SCD 19101-D industrial LCD monitor (same design as SCD 1898-I) Desktop unit, 230 V AC, 48 cm (19") screen diagonal, horizontal frequency 50...97 kHz, IP20 degree of protection Order No. 6GF6 220-1DA01 B) Additional and expansion components Connection cable • Video + Touch, 1.8 m long 6AV8 107-0BA00-0AA0 • Video + Touch, 5 m long 6AV8 107-0DA00-0AA0 • Video + Touch, 10 m long 6AV8 107-0FA00-0AA0 • Video, connecting cable 20 m long 6AV8 107-0HB00-0AA0 B) Subject to export regulations: AL: N, ECCN: EAR99H Outstanding characteristics of the SCD 19101-D LCD monitor include: 7 Rugged, fail-safe and long-life industrial design: - High resistance to shock and vibration - Extremely high electromagnetic compatibility - Anti-glare and hardened mineral glass pane for high mechanical protection - IP20 degree of protection - Complies with CE standard "Industry" 7 Modern design with exceptional ergonomics: - Sharp and high-contrast picture with uniform brightness - No flickering - Large reading angle up to 170° horizontal and vertical - Automatic picture adjustment (Auto Adjust) 7 No X-rays 7 Low energy consumption and heat development 7 Small space requirement and low weight 7 Configuration using on-screen display (OSD) 7 Long service life Siemens ST PCS 7 · November 2007 2/17 2 © Siemens AG 2007 System-neutral components SIMATIC PCS 7 Industrial Workstation 2 Special configurations ■ Overview The SIMATIC PCS 7 Industrial Workstations offered in the catalog section "Basic hardware" already cover the majority of applications. In the case of special system requirements, particularly if several supplementary/expansion components such as multiVGA graphics card, signal module or memory expansion have to be integrated at the same time, we also offer the possibility for ordering completely assembled special configurations of these SIMATIC PCS 7 Industrial Workstations. A special SIMATIC PCS 7 Industrial Workstation can be compiled interactively on the Internet using a configurator, and its Order No. generated in the process. This can subsequently be transferred to the shopping cart for ordering. Configurator in the A&D Mall The configurator "Special SIMATIC PCS 7 Industrial Workstations" is integrated in the catalog & online ordering system "A&D Mall" (www.siemens.com/automation/mall). It can be accessed there in two manners: Selection using quick link "Configuration list" A selection window in which all available configurators are categorized according to technical criteria is opened when you click the quick link "Configuration list" on the right side of the A&D Mall (see figure). You can find the configurator "Special SIMATIC PCS 7 Industrial Workstations" here in the category "Process automation". Selection using the "Siemens A&D product tree" If you click the link "Products" at the second position in the horizontal primary navigation (see blue area at the top in the figure), the "Siemens A&D product tree" is displayed on the left. Navigate there from "Process automation" via "Process control systems", "SIMATIC PCS 7 V7.0" and "SIMATIC PCS 7 Industrial Workstations" on to "Special configurations". Select the "Configurators" tab here, and then the configurator "Special SIMATIC PCS 7 Industrial Workstations". 2/18 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Starter systems 3/2 3/2 3/4 3/8 SIMATIC PCS 7 BOX Introduction SIMATIC PCS 7 BOX RTX SIMATIC PCS 7 BOX 416 3/13 Runtime Basic Packages Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Starter systems SIMATIC PCS 7 BOX Introduction ■ Overview ■ Design Two SIMATIC PCS 7 BOX systems with different performances are currently available: • SIMATIC PCS 7 BOX RTX with WinAC RTX software controller • SIMATIC PCS 7 BOX 416 with WinAC Slot 416 hardware controller 3 SIMATIC PCS 7 BOX 416 with WinAC Slot 416 hardware controller SIMATIC PCS 7 BOX RTX with WinAC RTX software controller SIMATIC PCS 7 AS RTX with WinAC RTX software controller Runtime system with AS functionality Runtime systems with AS and OS functionality or all-in-one systems with AS, OS and ES functionality Scalable automation performance in the bottom performance range of SIMATIC PCS 7 (for SIMATIC PCS 7 AS RTX, see page 10/4) SIMATIC PCS 7 BOX systems are compact and rugged industrial PCs as low-price starter solutions for process automation with SIMATIC PCS 7. They are available in two versions: • SIMATIC PCS 7 all-in-one system with functionality for automation (AS), HMI (OS) and engineering (ES) • SIMATIC PCS 7 Runtime system with AS and OS functionality Expanded by distributed process I/Os on the PROFIBUS, each version represents a complete process control system for small applications. ■ Application The SIMATIC PCS 7 BOX starter systems can be used for various applications: • Small production applications • Enclosed subprocesses (package units) • Automation of a laboratory or test center Together with the compact SIMATIC PCS 7 AS RTX Microbox automation system (see page 10/4), these allow finer scaling of the automation performance in the bottom performance range of SIMATIC PCS 7. It is then possible to react more variably to individual customer requirements with small applications. With regard to the achievable quantity framework, the SIMATIC PCS 7 BOX systems are approximately comparable with the following standard automation systems: • SIMATIC PCS 7 BOX 416 with an AS 416 • SIMATIC PCS 7 BOX RTX with an AS 414 In a direct comparison of the two systems, the SIMATIC PCS 7 BOX RTX impresses primarily due to the following advantages: • Low price • Very fast program execution Particular advantages of the SIMATIC PCS 7 BOX 416 are: • High availability • Support of changes to the configuration during runtime (CiR) through the stand-alone WinAC Slot CPU ES PDM OS CPU 416-2 24 V DC CP 5611 onboard DP MPI/DP SIMATIC PCS 7 BOX PROFIBUS DP PROFIBUS MPI/DP DP/PA link PROFIBUS PA As a fully adequate member of the SIMATIC PCS 7 range, they work with the PCS 7 standard system software, are scalable, and can be expanded without destroying the compatibility. However, the engineering and runtime licenses for AS and OS are limited to 2000 POs (process objects). Use as asset management station SIMATIC PCS 7 BOX can be incorporated into the PC diagnostics of the SIMATIC PCS 7 asset management using the SIMATIC PC DiagMonitor software. Equipped as an all-in-one system with software licenses for SIMATIC PDM and SIMATIC PCS 7 asset management, they are additionally suitable for use as a maintenance station. For further information, see Chapter "Asset management". 3/2 Siemens ST PCS 7 · November 2007 Stand-alone operation using example of a SIMATIC PCS 7 BOX 416 © Siemens AG 2007 Starter systems SIMATIC PCS 7 BOX Introduction SIMATIC PCS 7 BOX PDM ES OS CPU 416-2 24 V DC Ethernet onboard Ethernet CP 5611 onboard onboard DP MPI/DP PROFIBUS MPI/DP PROFIBUS PROFIBUS PA OS-LAN (Terminal bus) A system produced with SIMATIC PCS 7 BOX can be expanded at any time by further SIMATIC PCS 7 hardware and software components. It is just as easy to integrate SIMATIC PCS 7 BOX into existing SIMATIC PCS 7 systems. The connections on the plant bus and OS-LAN (terminal bus) are made using the Ethernet interfaces integrated in the SIMATIC PCS 7 BOX. The engineering licenses as well as the runtime licenses for AS and OS are administered by the engineering software. DP/PA link Plant bus SIMATIC PCS 7 BOX systems can be operated in stand-alone mode and also in the system network with other SIMATIC PCS 7 system components. The two architectures are illustrated using examples of the SIMATIC PCS 7 BOX 416. OS clients OS server With a SIMATIC PCS 7 BOX all-in-one system, the runtime licenses for AS and OS are components of the engineering software, and can be expanded by AS/OS Software Engineering PowerPacks to a maximum of 2000 POs. With a SIMATIC PCS 7 BOX runtime system, the OS Runtime licenses can be expanded by OS Software PowerPacks, the AS Runtime licenses by further AS Runtime licenses for 100 or 1000 POs to a maximum of 2000 POs. The process objects of additional AS Runtime licenses are then added to process objects which already exist. The number and type (100 or 1000) of additional AS Runtime licenses are only limited by the expansion limit. Engineering system Automation systems Integration in the SIMATIC PCS 7 system network using example of the SIMATIC PCS 7 BOX 416 SIMATIC PCS 7 BOX systems (SIMATIC PCS 7 BOX RTX as well as SIMATIC PCS 7 BOX 416) are based on the industrial SIMATIC Box PC 627B which permits combination of the frequently distributed PCS functionality for automation, HMI and engineering in one system. They use standard system software of SIMATIC PCS 7 V7.0, and are integrated in the SIMATIC PCS 7 engineering and the PCS 7 project wizard. This guarantees full compatibility with SIMATIC PCS 7 V7.0. SIMATIC PCS 7 BOX can be configured either using the engineering software integrated in the system or a central engineering system. OS-specific changes in the configuration on the SIMATIC PCS 7 BOX or on the central engineering system can be downloaded online, i.e. without terminating OS process operation. SIMATIC PCS 7 BOX support ET 200M, ET 200ISP and ET 200S remote I/O stations connected over PROFIBUS DP by means of a comprehensive range of low-cost signal/function modules as well as intelligent field/process devices connected directly over PROFIBUS DP/PA. Siemens ST PCS 7 · November 2007 3/3 3 © Siemens AG 2007 Starter systems SIMATIC PCS 7 BOX SIMATIC PCS 7 BOX RTX ■ Overview ■ Design 3 All-metal enclosure, rack-mountable, also suitable for portrait assembly 1 vacant PCI expansion slot, e.g. for multi-VGA graphics card 1 x DVI-I (VGA via supplied adapter) DP interface (CP 5613) Slot for CompactFlash card (accessible from outside) COM1: Serial interface 1 Power supply 24 V DC 4 x USB 2.0 interfaces On/off button 2 x Gigabit Ethernet connection for 10/100/1000 Mbit/s Optical drive DVD +/- R/RW The SIMATIC PCS 7 BOX RTX equipped with a WinAC RTX software controller features an exceptional price/performance ratio. With regard to the automation performance, it is positioned slightly below the SIMATIC PCS 7 BOX 416, but is primarily characterized by its very fast program execution. The WinAC RTX software controller working on the SIMATIC Box PC 627B basic hardware only generates a low basic load, and particularly exhibits its strengths in applications characterized by real-time demands and a deterministic response. DP interface Power supply fan SIMATIC PCS 7 BOX RTX design SIMATIC PCS 7 BOX RTX systems are offered in the form of two product bundles: • Preinstalled SIMATIC PCS 7 all-in-one system with AS, ES and OS functionality, including AS/OS Engineering and Runtime licenses for 250 POs • Preinstalled SIMATIC PCS 7 runtime system with AS and OS functionality, including AS/OS Runtime license for 250 POs These bundles can be extended by the following expansion components (see also page 2/15 and catalog on PC-based Automation): • SIMATIC PCS 7 PowerPacks/Runtime licenses for up to 2000 POs • AS/OS Software Engineering PowerPack for all-in-one system • OS Software Single Station PowerPack and AS Runtime license for runtime system • SIMATIC PDM package for PCS 7 • SIMATIC PC keyboard • LC and CRT displays for office and industrial environments 3/4 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Starter systems SIMATIC PCS 7 BOX SIMATIC PCS 7 BOX RTX ■ Technical specifications ■ Technical specifications (cont.) Basic hardware: SIMATIC Box PC 627B Monitoring/diagnostics functions Design and equipment features Watchdog • Monitoring of program execution • Can be parameterized for fault scenario or restart • Monitoring time adjustable in the software Temperature • Processor temperature • Air inlet temperature • Temperature in vicinity of power supply (via SIMATIC PC DiagMonitor and SIMATIC PCS 7 Asset Management) Fans • Failure of device fan and power supply fan (via SIMATIC PC DiagMonitor and SIMATIC PCS 7 Asset Management) Design Rack-mountable device with rugged metal enclosure, suitable for wall and portrait mounting Degree of protection to EN 60529 IP20 CPU • Processor Intel Core 2 Duo T7400 2.16 GHz • Front Side Bus 667 MHz • Second Level Cache 4 MB Chipset Intel 945 GM Main memory 2 GB DDR2-667 SDRAM (2 x 1 GB) Graphics • Graphics controller Intel 2D/3D GMA950, integrated in chipset • Graphics memory Dynamic video memory 8 to 128 MB Operating hours counter • Resolutions/colors/frequencies • VGA: Max. 1600 x 1200 / 32 bit colors / 85 Hz • DVI: Max. 1600 x 1200 / 32 bit colors / 60 Hz (via SIMATIC PC DiagMonitor and SIMATIC PCS 7 Asset Management) Displays • Two-digit 7-segment display for visualization of POST codes during BIOS booting • Two programmable status LEDs Drives • Flash drive For CompactFlash card • Hard disk 3.5" SATA, 160 GB • Optical drive DVD ± R/RW • Diskette drive Connectable via USB (not included in scope of delivery) Interfaces • PROFIBUS (12 Mbit/s) Safety Protection class Protection class I compliant with IEC 61140 Safety directives EN 61131-2; UL508; CSA C22.2 No 142 Noise level 1 x 9-contact Sub-D socket, CP 5611-compatible, 1 x 9-contact Sub-D socket, CP 5613 Electromagnetic compatibility (EMC) • Ethernet 2 x 10/100/1000 Mbit/s (RJ 45) Emitted interference • USB 4 x USB 2.0/high-speed (2 x high-current) EN 55022 Class B; EN 61000-3-2 Class D EN 61000-3-3; FCC Class A • Serial 1 x COM1 (V.24), 9-contact SubD connector Immunity to conducted interference on the supply lines • Parallel - • Graphics connection 1 x DVI-I (DVI/VGA combined): • DVI: digital • VGA analog ± 2 kV (to IEC 61000-4-4; burst) ± 1 kV (to IEC 61000-4-5; symmetrical surge) ± 2 kV (to IEC 61000-4-5; asymmetrical surge) Immunity to interference on signal lines ± 1 kV (to IEC 61000-4-4; burst; length < 3 m) ± 2 kV (to IEC 61000-4-4; burst; length > 3 m) ± 2 kV (to IEC 61000-4-5; surge; length > 30 m) Immunity to static discharge ± 6 kV contact discharge (to IEC 61000-4-2) ± 8 kV air discharge (to IEC 61000-4-2) Immunity to high-frequency irradiation 10 V/m, 80 to 1000 MHz and 1.4 to 2 GHz, 80% AM (to IEC 61000-4-3) 1 V/m, 2 to 2.7 GHz, 80% AM (to IEC 61000-4-3) 10 V, 9 kHz to 80 MHz, 80% AM (to IEC 61000-4-6) Immunity to magnetic fields 100 A/m, 50/60 Hz (to IEC 61000-4-8) • Keyboard/mouse Operation < 55 dB (A) to DIN 45635-1 Connectable via USB (keyboard not included in scope of delivery) Operating system and diagnostics software Operating system Windows XP Professional MUI preinstalled on hard disk and enclosed on restore DVD, no activation necessary System-tested SIMATIC industrial software SIMATIC PC DiagMonitor Siemens ST PCS 7 · November 2007 3/5 3 © Siemens AG 2007 Starter systems SIMATIC PCS 7 BOX SIMATIC PCS 7 BOX RTX ■ Technical specifications 3 (cont.) Climatic conditions (cont.) Automation: WinAC software PLC Temperature Tested according to IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-14 • Operation • +5 to +45 °C (with DVD writer, only up to +40 °C) • +5 to +50 °C (power of all slots max. 20 W) • +5 to +55 °C (power of all slots max. 10 W) • Storage/transport -20 to +60 °C • Gradient Operation: max. 10 °C/h; storage: 20 °C/h, no condensation Relative humidity Tested according to IEC 60068-2-78, IEC 60068-2-30 • Operation 5 to 80% at 25 °C (no condensation) • Storage/transport 5 to 95% at 25 °C (no condensation) Mechanical environmental conditions Vibrations Tested according to IEC 60068-2-6 • Operation 10 to 58 Hz: 0.075 mm, 58 to 500 Hz: 9.8 m/s² Limitation with DVD writer: 10 to 58 Hz: 0.019 mm / 58 to 500 Hz: 2.5 m/s² Limitation with portrait assembly: 10 to 58 Hz: 0.0375 mm / 58 to 500 Hz: 4.9 m/s² • Storage/transport 5 to 9 Hz: 3.5 mm, 9 to 500 Hz: 9.8 m/s² Shock Tested according to IEC 60068-2-27, IEC 60068-2-29 • Operation 50 m/s², 30 ms Limitation with portrait assembly: 25 m/s², 30 ms • Storage/transport 250 m/s², 6 ms Approvals CE living accommodation • Emitted interference EN 61000-6-3: 2001 • Noise immunity EN 61000-6-1: 2001 CE industrial environment • Emitted interference EN 61000-6-4: 2001 • Noise immunity EN 61000-6-2: 2005 cULus UL 60950-1, Report E11 5352 and CAN/CSA-C22.2 No. 609501; UL508 and CAN/CSA-C22.2 No. 142; Power supply (electrically isolated) Power supply 24 V DC (-15% / +20%), SELV DC input current Continuous current up to 8 A (up to 14 A for 30 s during startup) Max. power consumption (at 24 V DC) 210 W Dimensions and weights Dimensions including DVD writer (W x H x D) in mm 297 x 267 x 100 Weight Approx. 7 kg 3/6 ■ Technical specifications Siemens ST PCS 7 · November 2007 CPU WinAC RTX software controller for SIMATIC Box PC 627B with Windows XP Professional operating system, preconfigured for SIMATIC PCS 7 All-in-one system Preinstalled software/license PCS 7 Engineering Software V7.0 for AS/OS Number of process objects (AS/OS engineering and runtime) 250 POs (expandable per PowerPack to 2000 POs) Runtime system Preinstalled software/license PCS 7 OS Software Single Station V7.0 and SIMATIC PCS 7 AS Runtime license Number of process objects (runtime) • 250 POs for OS (expandable per PowerPack to 2000 POs) • 250 POs for AS (expandable per AS Runtime license) © Siemens AG 2007 Starter systems SIMATIC PCS 7 BOX SIMATIC PCS 7 BOX RTX ■ Selection and Ordering Data ■ Selection and Ordering Data Order No. SIMATIC PCS 7 BOX RTX all-inone system (ES, OS and AS) assembled and preinstalled, comprising: • SIMATIC Box PC 627B, 24 V DC, with Windows XP Professional MUI operating system (German, English, French, Italian, Spanish), WinAC RTX software controller and SIMATIC PC DiagMonitor diagnostics software • Mouse • SIMATIC PCS 7 Engineering Software V7.0 for AS/OS including AS/OS Runtime license for productive operation, 250 POs, 5 languages (German, English, French, Italian, Spanish), floating license for 1 user 6ES7 650-2QA07-0YX0 SIMATIC PCS 7 BOX RTX runtime system (OS and AS) assembled and preinstalled, comprising: • SIMATIC Box PC 627B, 24 V DC, with Windows XP Professional MUI operating system (German, English, French, Italian, Spanish), WinAC RTX software controller and SIMATIC PC DiagMonitor diagnostics software • Mouse • SIMATIC PCS 7 OS Software Single Station V7.0, 250 POs, 5 languages (German, English, French, Italian, Spanish), single license for 1 installation • SIMATIC PCS 7 AS Runtime license, 250 POs 5 languages (German, English, French, Italian, Spanish), single license for 1 installation 6ES7 650-2QB07-0YX0 D) Order No. SIMATIC PCS 7 PowerPacks/licenses for runtime system 3 SIMATIC PCS 7 PowerPack OS Software Single Station V7.0 for extending the OS Software Single Station 5 languages (German, English, French, Italian, Spanish), executes with Windows XP Professional, single license for 1 installation Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions D) • From 250 POs to 1000 POs 6ES7 658-2AB07-0YD0 • From 1000 POs to 2000 POs 6ES7 658-2AC07-0YD0 SIMATIC PCS 7 AS Runtime license (can be added to existing licenses) 5 languages (German, English, French, Italian, Spanish), executes with Windows XP Professional, single license for 1 installation Type of delivery: License key disk, certificate of license, terms and conditions • 100 POs 6ES7 653-2BA00-0XB5 • 1000 POs 6ES7 653-2BB00-0XB5 SIMATIC PDM Additional and expansion components SIMATIC PCS 7 PowerPacks for all-in-one system SIMATIC PCS 7 PowerPack Engineering Software AS/OS V7.0 for extending the engineering software for AS/OS 5 languages (German, English, French, Italian, Spanish), executes with Windows XP Professional, floating license for 1 user Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions • From 250 to 1000 POs, including AS/OS Runtime license 6ES7 658-5AB07-0YD5 • From 1000 to 2000 POs, including AS/OS Runtime license 6ES7 658-5AC07-0YD5 D) Subject to export regulations: AL: N, ECCN: 5D992B1 SIMATIC PDM PCS 7 V6.0 Complete package for integration into the engineering toolset of the SIMATIC PCS 7 engineering system 5 languages (German, English, French, Italian, Spanish), executes with Windows 2000 Professional or Windows XP Professional, floating license for 1 user, with: • SIMATIC PDM Basic • Option "Integration in STEP 7/PCS 7" • Option "Routing through S7400" • Option "128 TAGs" Software and electronic documentation on toolset DVD Type of delivery: • License key disk, emergency key disk, certificate of license, terms and conditions • 2 CDs with SIMATIC PDM V6.0 and device library Note: TAG options and PowerPacks: see page 4/14 6ES7 658-3LX06-0YA5 Further SIMATIC PCS 7 system software • SIMATIC BATCH: see Section "Batch automation" • SIMATIC PCS 7 asset-management: see Section "Asset management" SIMATIC PC keyboard (USB connection) • International key assignment 6ES7 648-0CB00-0YA0 Siemens ST PCS 7 · November 2007 3/7 © Siemens AG 2007 Starter systems SIMATIC PCS 7 BOX SIMATIC PCS 7 BOX 416 ■ Overview ■ Design 3 All-metal enclosure, rack-mountable, also suitable for portrait assembly RUN/STOP LEDs RUN mode switch Backup battery connection MPI/DP interface External connection 24 V DC supply DP interface 1 x DVI-I (VGA via supplied adapter) 1 vacant PCI expansion slot, e.g. for multi-VGA graphics card Slot for CompactFlash card (accessible from outside) COM1: Serial interface 1 Power supply 24 V DC 4 x USB 2.0 interfaces On/off button 2 x Gigabit Ethernet connection for 10/100/1000 Mbit/s Optical drive DVD +/- R/RW The SIMATIC PCS 7 BOX 416 equipped with a WinAC Slot 416 V4.0 hardware controller is based like the SIMATIC PCS 7 BOX RTX on the industrial PC SIMATIC Box PC 627B. With regards to the automation performance, it is positioned slightly above the SIMATIC PCS 7 BOX RTX, and is particularly recommendable if high availability or changes to the configuration during operation (CiR) are relevant factors for the selection. DP interface Power supply fan Design of SIMATIC PCS 7 BOX 416 SIMATIC PCS 7 BOX 416 systems are offered in the form of two product bundles: • Preinstalled SIMATIC PCS 7 all-in-one system with AS, ES and OS functionality, including AS/OS Engineering and Runtime licenses for 250 POs • Preinstalled SIMATIC PCS 7 runtime system with AS and OS functionality, including AS/OS Runtime license for 250 POs These bundles can be extended by the following expansion components (see also page 2/15 and catalog on PC-based Automation): • SIMATIC PCS 7 PowerPacks/Runtime licenses for up to 2000 POs - AS/OS Software Engineering PowerPack for all-in-one system - OS Software Single Station PowerPack and AS Runtime license for runtime system • SIMATIC PDM package for PCS 7 • SIMATIC PC keyboard • LC and CRT displays for office and industrial environments • SITOP smart power supply 230 AC/24 V DC, 240 W • SITOP DC UPS module 15 A with RS 232 interface • DC UPS software for further processing of the signals sent by the DC UPS module with RS 232 interface on the PC (status visualization as well as definition of response to various operating states of the DC UPS module), executes with Windows NT, 2000 and XP; freeware for downloading at www.siemens.com/sitop • SITOP battery module 24 V DC/20 A/7 Ah for DC UPS module 15 A 3/8 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Starter systems SIMATIC PCS 7 BOX SIMATIC PCS 7 BOX 416 ■ Function ■ Technical specifications WinAC Slot 416 V4.0 Basic hardware: SIMATIC Box PC 627B Through use of the WinAC Slot 416 V4.0, it is possible for the automation program in the Slot CPU to execute completely autonomously from the SIMATIC Box PC and its Windows operating system. Therefore the system can be restarted even if the SIMATIC Box PC is switched off or faulty. 24 V DC from a separate source is connected to the Slot CPU to provide a power supply independent of the PC. Neither software faults on the PC side, nor a power loss, nor rebooting of the PC have an effect on execution of the automation program in the Slot CPU. Design and equipment features If one of the following events occurs, the automation program is immediately informed and can thus react accordingly, e.g. by intermediate storage of production data and transfer of the system to a defined status: • Shutting-down of the Windows operating system • Fault in the Windows operating system ("blue screen") • Failure of PC-internal communication • Switching-off of the PC (Separate 24 V DC supply required) With the SIMATIC PCS 7 BOX 416, the process I/O is connected via the two PROFIBUS DP ports of the WinAC Slot 416 V4.0. In conjunction with SIMATIC PCS 7 V7.0, the WinAC Slot 416 V4.0 also permits changes to the configuration during operation (CiR). The type and scope of online modifications depend on the process I/O used. Since SIMATIC PDM can only access field devices on the PROFIBUS DP via the onboard CP 5611 communications processor, an additional link is required between the DP port and the CP 5611. The plug required belongs to the scope of delivery of the SIMATIC PCS 7 BOX 416. Use with SIMATIC BATCH SIMATIC PCS 7 BOX 416 systems can also be used for automation of batch processes with SIMATIC BATCH. The capacity of SIMATIC BATCH is limited to 10 UNITs (instances of plant units) in this case. The following SIMATIC BATCH option packages can be executed on the SIMATIC PCS 7 BOX in addition to the SIMATIC BATCH Server Basic Package for up to 10 UNITs: • Batch Control Center • Recipe System • Batch Planning • Hierarchical Recipe • ROP Library • Separation Procedures/Formulas Design Rack-mountable device with rugged metal enclosure, suitable for wall and portrait mounting Degree of protection to EN 60529 IP20 CPU • Processor Intel Core 2 Duo T7400 2.16 GHz • Front Side Bus 667 MHz • Second Level Cache 4 MB Chipset Intel 945 GM Main memory 2 GB DDR2-667 SDRAM (2 x 1 GB) Graphics • Graphics controller Intel 2D/3D GMA950, integrated in chipset • Graphics memory Dynamic video memory 8 to 128 MB • Resolutions/colors/frequencies • VGA: Max. 1600 x 1200 / 32 bit colors / 85 Hz • DVI: Max. 1600 x 1200 / 32 bit colors / 60 Hz Drives • Flash drive For CompactFlash card • Hard disk 3.5" SATA, 160 GB • Optical drive DVD ± R/RW • Diskette drive Connectable via USB (not included in scope of delivery) Interfaces • PROFIBUS/MPI 1 x 9-contact Sub-D socket, 12 Mbit/s (electrically isolated, CP 5611-compatible) • Ethernet 2 x 10/100/1000 Mbit/s (RJ 45) • USB 4 x USB 2.0/high-speed (2 x high-current) • Serial 1 x COM1 (V.24), 9-contact Sub-D connector • Parallel - • Graphics connection 1 x DVI-I (DVI/VGA combined): • DVI: digital • VGA analog • Keyboard/mouse Connectable via USB (keyboard not included in scope of delivery) Use with SIMATIC Route Control SIMATIC PCS 7 BOX 416 systems are not only suitable for automation of batch processes with SIMATIC BATCH, but also for control of material transports with SIMATIC Route Control. The capacity of SIMATIC Route Control is limited to 30 simultaneous material transports in this case. The SIMATIC Route Control Server and SIMATIC Route Control Center runtime software is then executed on the SIMATIC PCS 7 BOX 416. The Route Control Engineering is also possible on a SIMATIC PCS 7 BOX 416 all-in-one system. Operating system and diagnostics software Operating system Windows XP Professional MUI preinstalled on hard disk and enclosed on restore DVD, no activation necessary System-tested SIMATIC industrial software SIMATIC PC DiagMonitor Siemens ST PCS 7 · November 2007 3/9 3 © Siemens AG 2007 Starter systems SIMATIC PCS 7 BOX SIMATIC PCS 7 BOX 416 ■ Technical specifications (cont.) 3 ■ Technical specifications (cont.) Monitoring/diagnostics functions Watchdog Climatic conditions • Monitoring of program execution • Can be parameterized for fault scenario or restart • Monitoring time adjustable in the software • Processor temperature • Air inlet temperature • Temperature in vicinity of power supply (via SIMATIC PC DiagMonitor and SIMATIC PCS 7 Asset Management) Temperature Fans • Failure of device fan and power supply fan (via SIMATIC PC DiagMonitor and SIMATIC PCS 7 Asset Management) Operating hours counter (via SIMATIC PC DiagMonitor and SIMATIC PCS 7 Asset Management) Displays • Two-digit 7-segment display for visualization of POST codes during BIOS booting • Two programmable status LEDs Temperature Tested according to IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-14 • Operation • +5 ... +45 °C (with DVD writer, only up to +40 °C) • +5 ... +50 °C (power of all slots max. 20 W) • +5 ... +55 °C (power of all slots max. 10 W) • Storage/transport -20 ... +60 °C • Gradient Operation: max. 10 °C/h; storage: 20 °C/h, no condensation Relative humidity Tested according to IEC 60068-2-78, IEC 60068-2-30 • Operation 5 ... 80% at 25 °C (no condensation) • Storage/transport 5 ... 95% at 25 °C (no condensation) Mechanical environmental conditions Vibrations Tested according to IEC 60068-2-6 • Operation 10 to 58 Hz: 0.075 mm, 58 to 500 Hz: 9.8 m/s² Limitation with DVD writer: 10 to 58 Hz: 0.019 mm / 58 to 500 Hz: 2.5 m/s² Limitation with portrait assembly: 10 to 58 Hz: 0.0375 mm / 58 to 500 Hz: 4.9 m/s² • Storage/transport 5 ... 9 Hz: 3,5 mm, 9 to 500 Hz: 9.8 m/s² Shock Tested according to IEC 60068-2-27, IEC 60068-2-29 • Operation 50 m/s², 30 ms Limitation with portrait assembly: 25 m/s², 30 ms • Storage/transport 250 m/s², 6 ms Safety Protection class Protection class I compliant with IEC 61140 Safety directives EN 61131-2; UL508; CSA C22.2 No 142 Noise level Operation < 55 dB (A) to DIN 45635-1 Electromagnetic compatibility (EMC) Emitted interference EN 55022 Class B; EN 61000-3-2 Class D EN 61000-3-3; FCC Class A Immunity to conducted interference on the supply lines ± 2 kV (to IEC 61000-4-4; burst) ± 1 kV (to IEC 61000-4-5; symmetrical surge) ± 2 kV (to IEC 61000-4-5; asymmetrical surge) Immunity to interference on signal lines Immunity to static discharge Immunity to high-frequency irradiation Immunity to magnetic fields 3/10 ± 1 kV (to IEC 61000-4-4; burst; length < 3 m) ± 2 kV (to IEC 61000-4-4; burst; length > 3 m) ± 2 kV (to IEC 61000-4-5; surge; length > 30 m) ± 6 kV contact discharge (to IEC 61000-4-2) ± 8 kV air discharge (to IEC 61000-4-2) 10 V/m, 80 to 1000 MHz and 1.4 to 2 GHz, 80% AM (to IEC 61000-4-3) 1 V/m, 2 to 2.7 GHz, 80% AM (to IEC 61000-4-3) 10 V, 9 kHz to 80 MHz, 80% AM (to IEC 61000-4-6) 100 A/m, 50/60 Hz (to IEC 61000-4-8) Siemens ST PCS 7 · November 2007 Approvals CE living accommodation • Emitted interference EN 61000-6-3: 2001 • Noise immunity EN 61000-6-1: 2001 CE industrial environment • Emitted interference EN 61000-6-4: 2001 • Noise immunity EN 61000-6-2: 2005 cULus UL 60950-1, Report E11 5352 and CAN/CSA-C22.2 No. 60950-1; UL508 and CAN/CSA-C22.2 No. 142 Power supply (electrically isolated) Power supply 24 V DC (-15% / +20%), SELV DC input current Continuous current up to 8 A (up to 14 A for 30 s during startup) Max. power consumption (at 24 V DC) 210 W Dimensions and weights Dimensions including DVD writer (W x H x D) in mm 297 x 267 x 100 Weight Approx. 7 kg © Siemens AG 2007 Starter systems SIMATIC PCS 7 BOX SIMATIC PCS 7 BOX 416 ■ Technical specifications (cont.) ■ Selection and Ordering Data Automation: WinAC Slot PLC module CPU WinAC Slot 416 V4.0 hardware controller for SIMATIC Box PC 627B with Windows XP Professional operating system Main memory 1.6 + 1.6 MB (integrated) Load memory 256 KB Memory card 2 MB RAM (fitted) Execution times Binary command: 0.04 µs, IEEE floating-point: 0.12 µs PROFIBUS DP PROFIBUS DP and PROFIBUS DP/MPI interfaces onboard Dimensions PCI plug-in card (3/4 long) All-in-one system Preinstalled software/license PCS 7 Engineering Software V7.0 for AS/OS Number of process objects (AS/OS engineering and runtime) 250 POs (expandable per PowerPack to 2000 POs) Runtime system Preinstalled software/license PCS 7 OS Software Single Station V7.0 and SIMATIC PCS 7 AS Runtime license Number of process objects (runtime) • 250 POs for OS (expandable per PowerPack to 2000 POs) • 250 POs for AS (expandable per AS Runtime license) Order No. SIMATIC PCS 7 BOX 416 all-inone system (ES, OS and AS) assembled and preinstalled, comprising: • SIMATIC Box PC 627B, 24 V DC, with WinAC Slot 416 V4.0, Windows XP Professional MUI operating system (German, English, French, Italian, Spanish) and DiagMonitor diagnostics software • Memory card 2 MB • Backup battery • Mouse • SIMATIC PCS 7 Engineering Software V7.0 for AS/OS including AS/OS Runtime license for productive operation, 250 POs, 5 languages (German, English, French, Italian, Spanish), floating license for 1 user 6ES7 650-2PA07-0YX0 D) SIMATIC PCS 7 BOX 416 runtime system (OS and AS) assembled and preinstalled, comprising: • SIMATIC Box PC 627B, 24 V DC, with WinAC Slot 416 V4.0, Windows XP Professional MUI operating system (German, English, French, Italian, Spanish) and DiagMonitor diagnostics software • Memory card 2 MB • Backup battery • Mouse • SIMATIC PCS 7 OS Software Single Station V7.0, 250 POs, 5 languages (German, English, French, Italian, Spanish), single license for 1 installation • SIMATIC PCS 7 AS Runtime license, 250 POs 5 languages (German, English, French, Italian, Spanish), single license for 1 installation 6ES7 650-2PB07-0YX0 D) D) Subject to export regulations: AL: N, ECCN: 5D992B1 Siemens ST PCS 7 · November 2007 3/11 3 © Siemens AG 2007 Starter systems SIMATIC PCS 7 BOX SIMATIC PCS 7 BOX 416 ■ Selection and Ordering Data 3 Order No. Additional and expansion components SIMATIC PCS 7 PowerPacks for all-in-one system SIMATIC PCS 7 PowerPack Engineering Software AS/OS V7.0 for extending the engineering software for AS/OS 5 languages (German, English, French, Italian, Spanish), executes with Windows XP Professional, floating license for 1 user Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions • From 250 to 1000 POs, including AS/OS Runtime license 6ES7 658-5AB07-0YD5 • From 1000 to 2000 POs, including AS/OS Runtime license 6ES7 658-5AC07-0YD5 SIMATIC PCS 7 PowerPacks/ licenses for runtime system SIMATIC PCS 7 PowerPack OS Software Single Station V7.0 for extending the OS Software Single Station 5 languages (German, English, French, Italian, Spanish), executes with Windows XP Professional, single license for 1 installation Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions ■ Selection and Ordering Data SIMATIC PDM PCS 7 V6.0 Complete package for integration into the engineering toolset of the SIMATIC PCS 7 engineering system 5 languages (German, English, French, Italian, Spanish), executes with Windows 2000 Professional or Windows XP Professional, floating license for 1 user, with: • SIMATIC PDM Basic • Option "Integration in STEP 7/PCS 7" • Option "Routing through S7400" • Option "128 TAGs" Software and electronic documentation on toolset DVD Type of delivery: • License key disk, emergency key disk, certificate of license, terms and conditions • 2 CDs with SIMATIC PDM V6.0 and device library Note: TAG options and PowerPacks: see page 4/14 Further SIMATIC PCS 7 system software • SIMATIC BATCH: see Section "Batch automation" • SIMATIC PCS 7 asset-management: see Section "Asset management" SIMATIC PC keyboard (USB connection) • From 250 POs to 1000 POs 6ES7 658-2AB07-0YD0 • From 1000 POs to 2000 POs 6ES7 658-2AC07-0YD0 SIMATIC PCS 7 AS Runtime license (can be added to existing licenses) 5 languages (German, English, French, Italian, Spanish), executes with Windows XP Professional, single license for 1 installation Type of delivery: License key disk, certificate of license, terms and conditions • 100 POs 6ES7 653-2BA00-0XB5 • 1000 POs 6ES7 653-2BB00-0XB5 • International key assignment Siemens ST PCS 7 · November 2007 6ES7 648-0CB00-0YA0 Power supply 230 V AC / 24 V DC • SITOP smart 240W Stabilized load power supply, input: 120/230 V AC, output: 24 V DC / 10 A 6EP1 334-2AA01 • SITOP DC UPS module 24 V DC/15 A 1) with RS 232 interface and charger unit for 24 V lead battery Input: 24 V DC/16 A, output 24 V DC/15 A 6EP1 931-2EC31 • SITOP battery module 24 V DC/20 A/7 Ah for DC UPS module 15 A 6EP1 935-6ME21 1) 3/12 Order No. 6ES7 658-3LX06-0YA5 Additive DC UPS software (executes with Windows NT, 2000 and XP) for further processing of the signals sent by the DC UPS module with RS 232 interface on the PC; freeware for downloading at http://www.siemens.com/sitop © Siemens AG 2007 Starter systems Runtime Basic Packages ■ Overview ■ Selection and Ordering Data SIMATIC PCS 7 OS Software Single Station 1000 POs SIMATIC PCS 7 AS Runtime license (cumulative), 1000 POs (AS 414-3, AS 416-2) or 400 POs (AS 417-4-1H) AS 414-3 / AS 416-2 / AS 417-4-1H - Runtime license for 100 POs - UR2 rack - Without power supply - Without backup batteries - Without memory card Components of the Runtime Basic Package V7.0 The SIMATIC PCS 7 Runtime Basic Package V7.0 has been specially designed as a low-cost starter solution for process automation with SIMATIC PCS 7 automation systems of S7-400 design. The hardware and the system software of this product bundle are scalable, and can be expanded using other SIMATIC PCS 7 system components. The three versions differ with regards to the automation system used as platform: AS 414-3, AS 416-2 or AS 417-4-1H. The have a neutral design so that all options remain available for an individual system configuration. ■ Design A SIMATIC PCS 7 Runtime Basic Package V7.0 comprises: • One AS 414-3, AS 416-2 or AS 417-4-1H automation system with Runtime license for 100 POs as defined in the Chapter "Automation systems", in each case as follows: - UR2 rack (9 slots) - Without power supply, without backup batteries - Without memory card • One cumulative SIMATIC PCS 7 AS Runtime license with 1000 POs (AS-414-3, AS 416-2) or 400 PO (AS 417-4-H), single license for 1 installation • One SIMATIC PCS 7 OS Software Single Station V7.0, 1000 POs, single license for 1 installation Order No. SIMATIC PCS 7 Runtime Basic Package AS 414-3 comprising: • 1 x AS 414-3 automation system with Runtime license for 100 POs (according to definition in Chapter "Standard automation systems") - UR2 rack (9 slots) - Without power supply, without backup batteries - Without memory card • 1 x SIMATIC PCS 7 AS Runtime license, 1000 POs (cumulative), 6 languages (German, English, French, Italian, Spanish, Chinese), single license for 1 installation • 1 x SIMATIC PCS 7 OS Software Single Station V7.0, 1000 POs, 6 languages (German, English, French, Italian, Spanish, Chinese), single license for 1 installation 6ES7 650-3XG07-0YX0 D) SIMATIC PCS 7 Runtime Basic Package AS 416-2 comprising: • 1 x AS 416-2 automation system with Runtime license for 100 POs (according to definition in Chapter "Standard automation systems") - UR2 rack (9 slots) - Without power supply, without backup batteries - Without memory card • 1 x SIMATIC PCS 7 AS Runtime license, 1000 POs (cumulative), 6 languages (German, English, French, Italian, Spanish, Chinese), single license for 1 installation • 1 x SIMATIC PCS 7 OS Software Single Station V7.0, 1000 POs, 6 languages (German, English, French, Italian, Spanish, Chinese), single license for 1 installation 6ES7 650-3XH07-0YX0 D) D) Subject to export regulations: AL: N, ECCN: 5D992B1 Siemens ST PCS 7 · November 2007 3/13 3 © Siemens AG 2007 Starter systems Runtime Basic Packages ■ Selection and Ordering Data 3 SIMATIC PCS 7 Runtime Basic Package AS 417-4-1H comprising: • 1 x AS 417-4-1H automation system with Runtime license for 100 POs (according to definition in Chapter "Standard automation systems") - UR2 rack (9 slots) - Without power supply, without backup batteries - Without memory card • 1 x SIMATIC PCS 7 AS Runtime license, 400 POs (cumulative), 6 languages (German, English, French, Italian, Spanish, Chinese), single license for 1 installation • 1 x SIMATIC PCS 7 OS Software Single Station V7.0, 1000 POs, 6 languages (German, English, French, Italian, Spanish, Chinese), single license for 1 installation Order No. 6ES7 650-3XJ07-0YX0 D) Subject to export regulations: AL: N, ECCN: 5D992B1 3/14 Siemens ST PCS 7 · November 2007 D) © Siemens AG 2007 Engineering system 4/2 Introduction 4/3 4/3 ES hardware ES single station 4/4 4/4 4/5 4/10 4/11 4/12 4/13 ES software Introduction Standard engineering software Version Cross Manager Version Trail Import/Export Assistant SIMATIC PDM Process Device Manager 4/20 4/20 4/22 4/23 4/25 Engineering Process Safety Introduction Engineering F/FH systems SIMATIC Safety Matrix SIMATIC PCS 7 Safety ES Packages 4/26 4/26 Simulation Simulation with S7-PLCSIM Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Engineering system Introduction ■ Overview ■ Design Technological function blocks OS engineering 4 PCS 7 engineering CFC/SFC Libraries Import/ Export Assistant HW Config Graphics Designer Faceplate SIMATIC Designer BATCH S7 F Systems SIMATIC PDM SIMATIC Manager / uniform database Engineering for automation Engineering for network/ communication/hardware Engineering for fail-safe systems Parameterization of field devices The engineering system of the SIMATIC PCS 7 process control system is based on powerful PC technology combined with the Windows XP Professional operating system. This can also be used in offices or industrial environments. The engineering software executed on it can be optimally matched to different customer requirements and tasks. In accordance with the application, the following system versions are defined by licensing of the standard engineering software: • A classic, exclusive engineering station; not suitable for productive operation as an operator station • A combined engineering/operator station for small applications; also suitable for productive operation as an operator station The basic functionality covered by the standard engineering software can be optionally expanded depending on the projectspecific task and its implementation. 4/2 Siemens ST PCS 7 · November 2007 The control center of the engineering system is the SIMATIC Manager. It is the integration platform for the engineering toolset as well as the configuration basis for all engineering tasks of the SIMATIC PCS 7 process control system. All aspects of the SIMATIC PCS 7 project are created, managed, archived and documented here. A uniform database guarantees that once data have been entered they are available throughout the system. The engineering toolset contains tools which are optimally matched to one another for system-wide project-oriented engineering, and which simultaneously provide the basis for asset management of the I&C equipment. These include tools for effective engineering of the following components: • Control system hardware including distributed I/O and field devices • Communication networks • Automation functionality for continuous and batch processes (AS engineering) • Operation and monitoring functionality (OS engineering) • Safety applications (Safety Integrated for Process Automation) • Diagnostics and asset management functionality • Batch processes automated using SIMATIC BATCH • Material transports controlled using SIMATIC Route Control • Cooperation with higher-level CAD/CAE planning tools (importing and exporting of tags and example solutions) Technologists as well as process and production engineers can carry out planning and configuration in their acquainted environments when using this range of tools as well as predefined blocks (tag types) and plans (example solutions). © Siemens AG 2007 Engineering system ES hardware ES single station ■ Overview The scope of delivery also includes a mouse. The keyboard and monitor must be ordered separately (see page 2/15 and 2/17). Options/expansions A multi-VGA card can be added to the engineering system. 2 or 4 monitors can then be connected per station (see Section "SIMATIC PCS 7 Industrial Workstation" in Chapter "Systemneutral components"). ■ Technical specifications Detailed technical data of the single station version of the SIMATIC PCS 7 Industrial Workstation can be found at page 2/12 in tabular format. ■ Selection and Ordering Data Order No. Single station Just like the single-user system of the operator system, the central engineering system of the SIMATIC PCS 7 process control system is based on the single station version of a SIMATIC PCS 7 industrial workstation. This is characterized by powerful PC technology combined with the Windows XP Professional operating system. It can be used in offices or industrial environments. One process monitor can be connected to the integral graphics interface. Increased user-friendliness can be achieved by connecting up to 4 process monitors using a special multi-VGA graphics card. ■ Design The hardware platform for the engineering system of the SIMATIC PCS 7 process control system is the SIMATIC PCS 7 Industrial Workstation of single station design. This is based on the SIMATIC Rack PC 547B and is already prepared for installation in 19" rack systems. The SIMATIC PCS 7 Industrial Workstation of single station design is available in two versions which differ in their communications interface to the Industrial Ethernet plant bus: • SIMATIC PCS 7 ES/OS RACK PC 547B BCE WXP FastEthernet connection to plant bus with 10/100/1000 Mbit/s RJ45 network card and Basic Communication Ethernet (BCE) for communication with up to 8 automation systems (not faulttolerant) • SIMATIC PCS 7 ES/OS RACK PC 547B IE WXP FastEthernet connection to plant bus with CP 1613 communications processor (without limitations) Windows XP Professional MUI operating system (German, English, French, Italian, Spanish, Chinese) • SIMATIC PCS 7 ES/OS 547B BCE WXP Connection to plant bus with Ethernet network card RJ45 (PCI) 10/100/1000 Mbit/s and Basic Communication Ethernet (BCE) for up to 8 automation systems (not H-systems) 6ES7 650-0NF07-0YX0 D) • SIMATIC PCS 7 ES/OS 547B IE WXP Connection to plant bus with CP 1613 A2 communications processor 6ES7 650-0NF07-0YX1 D) Additional and expansion components SIMATIC NET S7-REDCONNECT Upgrade for communication with fault-tolerant AS systems, see page 9/28 Further additional and expansion components can be found at page 2/15 D) Subject to export regulations: AL: N, ECCN: 5D992B1 Note: Ordering data in abbreviated form; for detailed Ordering data, see page 2/14 The CP 1613 communication integrated in the IE version SIMATIC PCS 7 ES/OS RACK PC 547B IE WXP is a combination of CP 1613 communications processor and S7-1613 communications software. When using fault-tolerant automation systems, the ES/OS single station requires the S7-REDCONNECT software instead of the S7-1613 communications software. The S7-REDCONNECT Upgrade is suitable for upgrading the communications software (for ordering data, see page 9/29). The Windows XP Professional operating system and the SIMATIC PCS 7 engineering software for AS/OS are preinstalled on the SIMATIC PCS 7 Industrial Workstation on delivery. The scope of performance of the preinstalled SIMATIC PCS 7 engineering software is defined by installation of the purchased software licenses. A 10/100/1000 Mbit/s Ethernet RJ45 port is already onboard and can be used for connecting to an OS LAN (terminal bus). Siemens ST PCS 7 · November 2007 4/3 4 © Siemens AG 2007 Engineering system ES software Introduction ■ Overview 4 ■ Design The functionality of the engineering system is largely covered by the standard engineering software. The following software options are available in addition for special functions: • SIMATIC PCS 7 Import/Export Assistant • SIMATIC Version Cross Manager • SIMATIC Version Trail • Engineering Process Safety for safety applications based on Safety Integrated for Process Automation • SIMATIC PCS 7 Asset Engineering • SIMATIC Route Control Engineering • SIMATIC PDM Process Device Manager for SIMATIC PCS 7 • S7-PLCSIM for the functional testing of CFC/SFC programs SIMATIC PCS 7 engineering system with Windows XP Professional operating system Classic, exclusively engineering station Versions Can be used as operator station for No productive operation Combined engineering/ operator station for small applications Yes SIMATIC PCS 7 Industrial Workstation including operating system, alternatives BCE communication for up to 8 automation systems (not H systems) SIMATIC PCS 7 ES/OS 547B BCE WXP Communication IE SIMATIC PCS 7 ES/OS 547B IE WXP Additional IE communications software for SIMATIC PCS 7 ES/OS 547B IE WXP Software for IE communication with SIMATIC NET S7-REDCONNECT/2006 fault-tolerant automation systems Upgrade (additive to S7-1613) Standard engineering software, alternatives SIMATIC PCS 7 Engineering Software V7.0, without OS Runtime license for productive operation AS and OS, including 2-hour OS test operation ● OS, including 2-hour OS test operation ● AS ● SIMATIC PCS 7 AS and OS Engineering Software V7.0, with OS Runtime license for productive operation ● Supplementary engineering software (optional) Import/Export Assistant V7.0 ● Version Cross Manager V7.0 ● Engineering Process Safety S7 F Systems V6.0 ● Safety Matrix Tool ● PCS 7 Asset Engineering V7.0 ● SIMATIC Route Control Engineering V7.0 ● SIMATIC PDM PCS 7 V6.0 ● Simulation with S7-PLCSIM V5.4 ● Available hardware and software components of the engineering system, as well as possible configurations Note on Microsoft SQL Server software The "SQL Server" software from Microsoft delivered with SIMATIC PCS 7 may not be used outside the SIMATIC PCS 7 environment without the written approval of Siemens. 4/4 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Engineering system ES software Standard engineering software ■ Overview The standard engineering software provides the basic functionality for configuration of SIMATIC PCS 7 plants with: • Automation systems • Process I/O • Communication networks • Operator systems • Maintenance station • SIMATIC BATCH • SIMATIC Route Control Licensing of the standard engineering software depends on use of the engineering station as: • Classic, exclusive engineering station (not suitable for productive operation as an operator station) • Combined engineering/operator station for small applications (suitable for productive operation as an operator station) Classic, exclusive engineering station with unlimited number of process objects (POs) Three software versions with unlimited POs are available for the classic engineering station: • AS/OS - for engineering of automation systems (AS) and operator systems (OS) • OS - only for OS engineering • AS - only for AS engineering With the OS and AS/OS software versions, the OS configuration can be tested in an OS test mode limited to 2 hours. This OS test mode is not suitable for productive operation. After 2 hours, the engineering station automatically switches to demonstration mode. The AS/OS software version is additionally upgraded by adding an AS runtime license for 600 POs. By means of a Rental License limited to 30 days for AS engineering or OS engineering (unlimited POs in each case), a cost-effective alternative is offered for short-term projects or short-term capacity bottlenecks. Combined engineering/operator station for small applications (scalable POs) To support compact process control plants, an ES/OS software combination of limited volume is offered with 250, 1,000 or 2,000 POs. In addition to the engineering licenses, these "All-in-one Licenses" also contain runtime licenses for AS and OS with the corresponding volumes. PowerPacks enable further expansion of the volume: • From 250 POs to 1,000 POs • From 1,000 to 2,000 POs (in each case including AS/OS runtime license) • From 2,000 POs to unlimited POs (only with OS runtime license) ■ Function Essential tools of the standard engineering software and their functions: SIMATIC Logon Together with the versatile recording facilities provided by the modification logbook, SIMATIC Logon, the user administration and access control function used in the engineering system, offers plant owners exceptional system support when complying with FDA requirements. Using SIMATIC Logon, the administrator can assign specific access privileges to groups of users, thus controlling the possibilities for data access. Operator interventions in the engineering system as well as all online modifications which affect the automation systems, operator systems, SIMATIC BATCH or SIMATIC Route Control can be recorded in the modification reports. If the modification reports are linked to the data of SIMATIC Logon during evaluation, it can be clearly proven who has carried out a specific modification and at what time. SIMATIC Manager The SIMATIC Manager is the control center for engineering of the SIMATIC PCS 7 process control system. All aspects of the SIMATIC PCS 7 project are created, managed, archived and documented here. The tools for engineering of the hardware components, communication and application software are also called from here. The hardware required for use in a SIMATIC project, such as automation systems, communications components and process I/O, is stored in an electronic catalog. The hardware is configured and parameterized using the HW-Config tool. To create the automation logic, standardized function blocks are combined with one another in the graphic configuration tool CFC according to technological specifications. Predefined blocks (process tag types) or charts (example solutions) can be used for this purpose simply by selecting them from a catalog and then positioning, graphically interconnecting and parameterizing them in the working area. No detailed programming knowledge is required, one can completely concentrate on the technological aspects of configuration. The process tag data relevant to operation and monitoring, such as messages and variables, are generated at the same time as configuration of the automation functions. Sequential controls permit control and selective processing of the basic automation functions created per CFC by means of changes in operating mode and status. Powerful test and commissioning functions for the graphic configuration and commissioning of sequential controls are offered by the SFC editor. Complete SIMATIC PCS 7 projects or all project modifications can be compiled in one working step and downloaded to the target systems involved, e.g. automation systems, operator system or SIMATIC BATCH. The engineering system automatically ensures that the sequence is correct. The procedure is displayed and controlled in a central dialog. Selective configuration modifications can be downloaded online to the corresponding target systems. Short turnaround times result in short waiting times for the commissioning engineer, and have a favorable effect on the commissioning costs. Program modifications relevant to automation systems can be initially debugged in a test system prior to downloading to the target system of the running plant. Siemens ST PCS 7 · November 2007 4/5 4 © Siemens AG 2007 Engineering system ES software Standard engineering software Project views Multi-project engineering permits division of a large complex project into several subprojects in accordance with technological criteria in order to allow several teams to work on the project in parallel. To achieve this, a host "Multi-project" is defined in the SIMATIC Manager. Individual (sub)projects can be inserted into or removed from a multi-project at any time. Similarly, projects can be divided or combined (Branch & Merge). The SIMATIC Manager supports the various tasks for creating a plant project by means of the following project views: • Component view (HW-Config) for configuration of hardware such as automation systems, bus components or process I/O Central configuration functions for multi-projects help to reduce the configuration overhead. For example, a hierarchy folder can be created in the current project and also automatically in all other projects. It cannot be modified there, but objects can be inserted. All block types used in a multi-project can also be updated centrally. The (sub)projects belonging to a multi-project are saved on a central server and can be sent to local engineering stations for editing. The engineering performance is then not affected by network access. Concurrent engineering In the case of concurrent engineering, several configuration engineers can work in CFC and SFC simultaneously on a project without this having to be first divided into subprojects. The project is located on one of the engineering stations involved. This requires connections to the OS LAN (terminal bus) and plant bus in order to download the configuration data to the target systems. The engineering stations working as "project clients" can access the project data via the OS LAN (terminal bus) or a different LAN/WAN. A CFC can be opened and viewed simultaneously by several configuration engineers. However, simultaneous write operations to the database are rejected by the system. It is then possible, for example, to use charts in online (debugging) mode during commissioning while carrying out modifications to the project at the same time. Branch & Merge Branch & Merge supports the division and combination of projects from the technological viewpoint. Charts or plant units can be copied into another project and edited there. Interconnections which are not specific to a project, typically for interlocking, become text interconnections. When merging, charts with the same name are overwritten in the original object, and text interconnections – even those which you have entered yourself – can be closed by pressing a button. Component view: hardware configuration in the SIMATIC Manager with HW-Config • Process object view as the central development environment for all aspects of process tags/objects The process object view of the SIMATIC Manager supports the work of a process engineer by providing a universal view of the process tag. It shows the technological hierarchy of the plant (presented in tree form) in combination with a tabular view of all aspects of the process tag/object (general data, parameters, signals, messages, image objects and measured value archives). This provides the technologist with fast orientation. All objects in the marked branch of the hierarchy are displayed in the table so that they can be directly processed with userfriendly edit, filter, replace, import and export functions. A special test mode offers the facility for testing process tags and CFCs online and for starting them up. SIMATIC Manager Libraries 4 Multi-project engineering Process object view 4/6 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Engineering system ES software Standard engineering software The OS areas and the image hierarchy for process control, as well as the SIMATIC PCS 7 asset management, can be derived from the technological hierarchy. Furthermore, it also forms the basis for the plant-oriented identification of process objects. Common displays can be positioned in pictures by means of the image hierarchy, and automatically linked to subordinate images. The configuration engineer is only responsible for the correct positioning. Since the number of common display fields and their semantics can be configured, it is also possible to implement customized alarm configurations. Using the process object view, "Smart Alarm Hiding" can also be configured This function is understood as the dynamic hiding of messages (alarms) of the technological blocks grouped in a plant unit which are of secondary importance depending on the operating state of this unit (startup, service, etc.). Alarms can be displayed or hidden separately for each of the maximum 32 operating states through selection of option boxes in the alarm matrix of the process object view. Although hidden alarms are not signaled visually and audibly, they are still logged and archived as before. Continuous function chart (CFC) The CFC editor is the tool for graphical configuration and commissioning of continuous automation functions. Preengineered function blocks can be positioned, configured and interconnected within CFCs with the support of powerful autorouting and integral configuration of HMI messages. Special configuration techniques such as chart-in-chart for implementing hierarchical plans or the multiple usage of chart block types (chart compiled as block type) or SFC types (standardized sequential controls) in the form of instances offer an additional rationalization potential. When creating a new CFC, a new runtime group with the same name as the chart is created. All the blocks that are subsequently entered in the chart are automatically added to this runtime group. Each block is therefore already assigned runtime properties when inserting, and these properties can be optimized by means of modifications in the runtime editor or by using algorithms. Sequential function chart (SFC) The SFC editor is used for the graphical configuration and commissioning of sequential controls for batch production operations. It possesses convenient editing functions as well as powerful test and commissioning functions. Using a sequential control, basic automation functions usually created using CFC are controlled and selectively processed by means of changes in operating mode and status. Depending on the subsequent use, the sequential controls can be created either as a SFC plan or SFC type. SFC plan The SFC plan can be used to implement sequential controls which can be applied once and which access several partial areas of the production plant. Each SFC plan contains standardized inputs and outputs for status information and for control by the user program or the user. The SFC plan can be positioned and linked as a block in the CFC. The required CFC block connections are selected by simple operations and connected to the steps or transitions of the step chains. An ISA 88-conform status manager enables the configuration of up to 8 separate sequence chains within a single SFC, e.g. for states such as HOLDING or ABORTING, for SAFE STATE or for different operating modes. SFC type SFC types are standardized sequential controls which can be applied repeatedly and which access one partial area of the production plant. They can be organized in libraries, and handled like normal function blocks, i.e. they can be selected from a catalog and positioned, interconnected and parameterized as an instance in a CFC plan. Changes to the original automatically result in corresponding changes in all instances. An SFC type may contain up to 32 sequences. Using the function "Create/update block symbols", a block symbol is automatically positioned and interconnected in the associated process display for all SFC instances with HMI features. The algorithm first determines the optimum block sequence separately for each runtime group, and then the optimum sequence of runtime groups. In addition to convenient editing functions, the scope of CFC functions also includes powerful test and commissioning functions as well as individually configurable documentation functions. Sequential function chart Continuous function chart Siemens ST PCS 7 · November 2007 4/7 4 © Siemens AG 2007 Engineering system ES software Standard engineering software I&C libraries • Setting of control parameters dependent on working point The GainSched block has been designed for variable setting of controller parameters depending on the working point in non-linear controlled systems. The block functions similar to the polygon block, and can derive three separate output variables from the response of an input variable, and apply these as control parameters for a linked controller block. The GainSched block then adjusts the control parameters of the combined controller depending on the response of the actual value. 4 The faceplate of the GainSched block can be called from the faceplate of the associated controller. • Monitoring of control quality Examples of editable OS standard displays (faceplates) from the PCS 7 library Preconfigured and tested blocks, faceplates and symbols are organized in I&C libraries and form the basic elements for the graphic configuration of automation solutions. The use of these library elements plays a major role in minimizing the engineering input and project costs. The comprehensive range of blocks can be categorized as follows: • Simple logic and driver blocks • Technological blocks with integral operation and signaling functions such as PID controllers, motors or valves • Blocks for integration of PROFIBUS field devices in accordance with PROFIBUS PA profile 3.0 (including standardized evaluation of the process value status) • Blocks with more advanced control algorithms for Advanced Process Control (APC) functions The ConPerMon block can be used to monitor the quality of a controller block according to a patented procedure. The setpoint, actual value and manipulated variable of the controller block (e.g. PID controller) are connected to the ConPerMon block which determines the control quality using these online values. The block can trigger a warning or alarm depending on the deviation from a reference value, e.g. the control quality determined during commissioning. The faceplate of the ConPerMon block can be called from the faceplate of the associated controller. OS displays can be generated during engineering which list all deviations in the control quality of a plant or unit. The plant operator can use these displays to recognize problems early, and to analyze and specifically eliminate such before they result in serious deficiencies or a production failure. PID Tuner Advanced Process Control (APC) functions The APC functions concentrated in separate blocks expand the PID-based control functions of SIMATIC PCS 7 by more advanced control algorithms, e.g.: • Model-based multi-variable controller The use of a multi-variable controller is recommendable for complex processes where several variables which are mutually dependent have to be controlled. Separate control of the individual variables, e.g. using PID controllers, has the disadvantages that interactions result in different effects on the respective variables. The model-based ModPreCon multi-variable controller integrated in SIMATIC PCS 7 separately analyzes the response of up to four mutually dependent variables over a longer period of time. A parameter matrix is calculated from the results, and used by the ModPreCon for optimum control of the variables. Note: The ModPreCon makes great demands on memory and processing time of the designated automation system. For that reason, please check the resources of the designated automation system before use. We recommend the use of an automation system of type AS 416 or higher. The PID Tuner is a function integrated in the CFC for optimization of the CTRL_PID and CTRL_S software controllers. The optimum parameters for a control loop can then be determined for PID, PI and P control modes in defined steps. The tool is suitable for optimizing controlled systems with or without an integral component. Optimization can be carried out in manual or automatic mode. The transient response of the controllers with the determined parameters can be checked by defining jumps. The controller parameters can be saved, and recalled as required. During determination of the controller parameters, the typical controller values (actual value, setpoint, manipulated variable) are recorded by a trend function. 4/8 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Engineering system ES software Standard engineering software Graphics designer and faceplate designer The project data for the engineering of the operator systems are organized with the SIMATIC Manager. All the data relevant to operation and monitoring of a process tag, such as messages and HMI variables, are generated automatically during definition of the automation function. A powerful graphics designer is available for the generation of process displays. In addition to the standard faceplates, the faceplate designer is used to simply generate customized faceplates for operation and monitoring of process tags or plant components. Block symbols can be conveniently interconnected to process tags using Drag & Drop. DOCPRO DOCPRO is a tool for effective generation and management of plant documentation in accordance with defined standards. DOCPRO permits you to structure your project data in any manner, to process them in the form of standardized circuit manuals, and to print them in a uniform layout. You can incorporate your own cover sheets, layouts, graphics, logos or title block data. It is easy to control printing, i.e. you can specifically output individual parts of the project or all project data on the printer. ■ Selection and Ordering Data Order No. A classic, exclusive engineering station without limitation of quantities, not suitable for productive operation as an operator station SIMATIC PCS 7 Engineering Software V7.0 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows XP Professional, floating license for 1 user Electronic documentation on PCS 7 toolset DVD Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions; PCS 7 V7.0 toolset DVDs, Microsoft SQL Server 2005 including EULA and supplementary CDs/DVDs (e.g. Microsoft ServicePacks and tools) 6ES7 658-5AF07-0YA5 OS engineering software, enabled for two-hour OS test operation • Unlimited POs 6ES7 658-2DF07-0YA5 AS engineering software • Unlimited POs Order No. SIMATIC PCS 7 Engineering Software V7.0 Rental License 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows XP Professional Rental license for 30 days Type of delivery: License key disk, certificate of license, terms and conditions; PCS 7 V7.0 toolset DVDs, Microsoft SQL Server 2005 including EULA and supplementary CDs/DVDs (e.g. Microsoft ServicePacks and tools) 4 • For AS, unlimited POs 6ES7 658-1AF07-0YA6 C) • For OS, unlimited POs 6ES7 658-2DF07-0YA6 C) A combined engineering/operator station for small applications, suitable for productive operation as an operator station SIMATIC PCS 7 Engineering Software V7.0 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows XP Professional, floating license for 1 user Electronic documentation on PCS 7 toolset DVD Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions; PCS 7 V7.0 toolset DVDs, Microsoft SQL Server 2005 including EULA and supplementary CDs/DVDs (e.g. Microsoft ServicePacks and tools) AS/OS engineering software, including AS/OS Runtime license for productive operation AS/OS engineering software, enabled for two-hour OS test operation • Unlimited POs, including AS Runtime license for 600 POs ■ Selection and Ordering Data 6ES7 658-1AF07-0YA5 • 250 POs 6ES7 658-5AA07-0YA5 • 1000 POs 6ES7 658-5AB07-0YA5 • 2000 POs 6ES7 658-5AC07-0YA5 SIMATIC PCS 7 Engineering PowerPack AS/OS V7.0 for extending the engineering software for AS/OS of a combined ES/OS station 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows XP Professional, floating license for 1 user Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions • From 250 to 1000 POs, including AS/OS Runtime license 6ES7 658-5AB07-0YD5 • From 1000 to 2000 POs, including AS/OS Runtime license 6ES7 658-5AC07-0YD5 • From 2000 to unlimited POs, including OS Runtime license 6ES7 658-5AF07-0YD5 C) Subject to export regulations: AL: N, ECCN: EAR99S Siemens ST PCS 7 · November 2007 4/9 © Siemens AG 2007 Engineering system ES software Version Cross Manager ■ Overview ■ Selection and Ordering Data Order No. For SIMATIC PCS 7 applications SIMATIC Version Cross Manager V7.0 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows XP Professional or Windows Server 2003, floating license for 1 user Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions as well as TIA toolset CD V7.0 4 The SIMATIC Version Cross Manager is a user-friendly tool for determining the differences between various versions of individual projects or multi-projects by: • Tracing missing, additional or differing objects by comparing hardware configuration, communication, technological hierarchy, CFC/SFC plans, SFC details, block types, alarms, global variables, signals and run sequences • Graphic display of comparison results in a combination of tree and tabular formats • Clear hierarchical structuring according to the technological hierarchy of the plant • Color-coded identification of the differences ■ Function Data exchange with planning tools Using the SIMATIC Version Cross Manager you can also exchange data with planning tools (CAx data). It supports the following exchange functions: • Export of CAx-relevant data, e.g. global declarations, technological hierarchy or measuring points • Export of files in SIMATIC XML format (SML) • Import of CAx data present in SIMATIC XML format 6ES7 658-1CX07-2YA5 For TIA applications SIMATIC Version Cross Manager V7.0 6 languages (German, English, French, Spanish, Italian, Chinese), executes with Windows 2000 Professional, Windows XP Professional or Windows Server 2003, floating license for 1 user Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions as well as TIA toolset CD V7.0 6ES7 658-1CX07-2YA5 SIMATIC Version Cross Manager Upgrade V7.0 for upgrading from Version Cross Checker V6.0/V6.1 to Version Cross Manager V7.0 6 languages (German, English, French, Spanish, Italian, Chinese), executes with Windows 2000 Professional, Windows XP Professional or Windows Server 2003, floating license for 1 user Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions as well as TIA toolset CD V7.0 6ES7 658-1CX07-2YE5 The SIMATIC Version Cross Manager is a SIMATIC product which was developed for the SIMATIC PCS 7 process control system but which can also be used together with other SIMATIC products in the context of Totally Integrated Automation (TIA). In the case of products which can be used in both the SIMATIC PCS 7 and TIA environments, the ordering data and type of delivery may differ depending on the application. To provide a better overview and to avoid faulty ordering, the selection and ordering data of such products are therefore listed separately depending on the target application. ■ More information Upgrade Example of an XML export SIMATIC PCS 7 engineering systems with Engineering Software V6.0 or V6.1 can be upgraded to Version 7.0 using the SIMATIC PCS 7 Engineering Upgrade Package. This upgrade package also includes the upgrade from SIMATIC Version Cross Checker V6.0/V6.1 to SIMATIC Version Cross Manager V7.0. For applications outside SIMATIC PCS 7, a separate SIMATIC Upgrade Version Cross Manager V7.0 can be obtained for upgrading the SIMATIC Version Cross Checkers V6.0/V6.1. For further information, see Chapter "Update/upgrade packages". 4/10 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Engineering system ES software Version Trail ■ Overview ■ Selection and Ordering Data Order No. For SIMATIC PCS 7 applications Project Multi project Versioned project 1 Library Versioned project 2 SIMATIC Version Trail V7.0 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows XP Professional or Windows Server 2003, floating license for 1 user Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions as well as TIA toolset CD V7.0 6ES7 658-1FX07-2YA5 4 For TIA applications SIMATIC Version Trail is a software option for engineering which, together with the SIMATIC Logon central user administration, can assign a version history to libraries, projects and multiprojects. It can be used within SIMATIC PCS 7 or also in the context of Totally Integrated Automation with SIMATIC. ■ Function When archiving, SIMATIC Version Trail in association with SIMATIC Logon creates a version history with the following information: • Version • Version name • Date and time • User • Comment This version history can be displayed and printed. Individual version releases can be dearchived from the version history and used further. SIMATIC Logon organizes the access protection. SIMATIC Version Trail V7.0 6 languages (German, English, French, Spanish, Italian, Chinese), executes with Windows 2000 Professional, Windows XP Professional or Windows Server 2003, floating license for 1 user Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions as well as TIA toolset CD V7.0 6ES7 658-1FX07-2YA5 SIMATIC Version Trail Upgrade V7.0 6 languages (German, English, French, Spanish, Italian, Chinese), executes with Windows 2000 Professional, Windows XP Professional or Windows Server 2003, floating license for 1 user Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions as well as TIA toolset CD V7.0 6ES7 658-1FX07-2YE5 The SIMATIC Version Trail is a SIMATIC product which was developed for the SIMATIC PCS 7 process control system but which can also be used together with other SIMATIC products in the context of Totally Integrated Automation (TIA). In the case of products which can be used in both the SIMATIC PCS 7 and TIA environments, the ordering data and type of delivery may differ depending on the application. To provide a better overview and to avoid faulty ordering, the selection and ordering data of such products are therefore listed separately depending on the target application. ■ More information Upgrade SIMATIC PCS 7 engineering systems with Engineering Software V6.0 or V6.1 can be upgraded to Version 7.0 using the SIMATIC PCS 7 Engineering Upgrade Package. A component of this upgrade package is also the upgrade for SIMATIC Version Trail from V6.1 to V7.0. For applications outside SIMATIC PCS 7, a separate SIMATIC Upgrade Version Trail V7.0 can be obtained for upgrading SIMATIC Version Trail V6.1. For further information, see Chapter "Update/upgrade packages". Note: Please note that Version Trail cannot be used on its own, but only in combination with SIMATIC Logon (see page 2/4). Siemens ST PCS 7 · November 2007 4/11 © Siemens AG 2007 Engineering system ES software Import/Export Assistant ■ Overview ■ Benefits CAD/CAE 4 Higher-level planning tools Import/export assistant Typical libraries Example solutions and process object types (e.g. control, motor, valve) Process object plans OS display hierarchy Technological hierarchy The import/export assistant offers the following benefits when using previously configured plant data: 7 Importing of previously configured plant data from the host CAD/CAE world, such as process tag list - No multiple inputs with the associated input errors - Simple handling, easy-to-use graphic environment 7 Automatic and reproducible generation of process tags and derivatives based on the imported process tag lists and example solutions (technological hierarchy, charts of the individual process tags) - Drastic reduction in time required, and avoidance of errors 7 Automatic derivation of the OS display hierarchy, automatic interconnecting of blocks and positioning in displays - Considerable reduction in time required and costs 7 Commissioning of individual process tags with the userfriendly CFC and SFC graphic tools 7 Exporting of parameters optimized during commissioning back to the CAD/CAE world - Consistent data in the host planning tools ■ Function OS displays Efficient processing of mass data The import/export assistant (IEA) is an effective tool for rational engineering of mass data, and is based on multiple use of process tag types and example solutions. It is particularly suitable for large plants with many process tags of the same type or with several plant components of the same type. Plant data which have already been configured (such as process tag lists or charts from the CAD/CAE world) can be imported into the engineering system and used for largely automatic generation of process tags. The data of the host planning system can be subsequently matched again with the parameters optimized during commissioning. To permit simple and fast modification, the PCS 7 projects can also be exported, the data processed using the IEA editor or other programs (e.g. Microsoft Excel or Access), and subsequently reimported. • Generation/modification of process tag types or example solutions • Importing of data from plant planning - Generation of process tags from process tag types and derivatives from example solutions; provision with data from the import file (one process tag/derivative per import file line in each case) - Assignment of an import file to a process tag type, and checking of the assignment - Generation of a template for an input file for the process tag • Exporting of data for plant planning - Generation of an export file per process tag type/example solution in each case, with one line for each process tag of this type or each derivative of this example solution • Matching of process tags - Removal of parameter/signal connection points not present on the process tag type and of messages from the process tags - Addition of parameter/signal connection points and messages newly defined on the process tag type - Correction of modified categories of process tag type - Display of inconsistencies between process tag and type which cannot be matched automatically ■ Selection and Ordering Data SIMATIC PCS 7 Import/Export Assistant V7.0 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows XP Professional, floating license for 1 user Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions 4/12 Siemens ST PCS 7 · November 2007 Order No. 6ES7 658-1DX07-2YB5 © Siemens AG 2007 Engineering system ES software SIMATIC PDM Process Device Manager ■ Overview SIMATIC PDM SIMATIC PCS 7 engineering station with SIMATIC PDM SIMATIC PDM SIMATIC PDM SIMATIC Device on the workbench PDM 4 Plant bus SITRANS P S7-400 S7-400 SIMATIC PDM Stand-alone computer with SIMATIC PDM SIMATIC PDM SIMATIC PDM PROFIBUS DP fieldbus HART protocol Up to 12 Mbit/s ET 200M (IM 153-2 with HART modules) MICROMASTER ET 200iSP SIMOCODE pro PROFIBUS PA SIMATIC PDM RS 232/RS 485 HART multiplexer HART DP/PA link SIMATIC PDM SIMATIC SIMATIC PDM PDM SIMATIC PDM HART device SIPART PS2 SITRANS P SITRANS T3K SIMATIC SITRANS LR SITRANS F M SIPART PS2 PDM Possible connection point of a PG/PC with SIMATIC PDM (stand-alone operation) Configuration options with SIMATIC PDM SIMATIC PDM (Process Device Manager) is a universal, vendorindependent tool for the configuration, parameterization, commissioning, diagnostics and servicing of intelligent field devices (sensors and actuators) and field components (remote I/Os, multiplexers, control-room devices, compact controllers), which in the following sections will be referred to simply as devices. Using one software, SIMATIC PDM enables the processing of more than 1200 devices from Siemens and over 100 vendors worldwide on one homogeneous user interface. Parameters and functions for all supported devices are displayed in a consistent and uniform fashion independent of their communications interface. From the viewpoint of device integration, SIMATIC PDM is the most powerful open device manager available in the world. Devices which previously were not supported can be easily integrated in SIMATIC PDM at any time by importing their device descriptions (EDD). This provides security for your investment and saves you investment costs, training expenses and consequential costs. SIMATIC PDM is integrated in the asset management of SIMATIC PCS 7. The Process Device Manager provides wider information for all devices described by the Electronic Device Description (EDD), e.g. detailed diagnostics information (vendor information, information on fault diagnostics and troubleshooting, further documentation), modification logbook (audit trial), parameter information. It is possible to change directly to SIMATIC PDM from the diagnostics faceplates in the maintenance station. Siemens ST PCS 7 · November 2007 4/13 © Siemens AG 2007 Engineering system ES software SIMATIC PDM Process Device Manager ■ Design Customer-oriented product structure 4 The SIMATIC PDM Process Device Manager can be used in a versatile manner in the context of Totally Integrated Automation (TIA). Use in the engineering system of SIMATIC PCS 7 is one possible application. The customer-oriented products structure of SIMATIC PDM supports you in adaptation of the scope of functions and performance to your individual requirements. You can select the minimum configuration SIMATIC PDM Single Point, one of the application-specific, predefined product configurations SIMATIC PDM Service, SIMATIC PDM PCS 7 or SIMATIC PDM S7, or produce your desired configuration from the individual components offered (see table). The selection depends on the application range and environment of use: • System-integrated in a SIMATIC PCS 7/S7 configuration environment: - SIMATIC PDM PCS 7 (for integration in an engineering system for SIMATIC PCS 7) - SIMATIC PDM S7 (for integration in a SIMATIC S7 configuration environment) • SIMATIC PDM stand-alone as service tool for operation on a mobile computer on the PROFIBUS or with direct connection to the device: - SIMATIC PDM Single Point (for processing of a single field device via a point-to-point coupling) - SIMATIC PDM Service (for enhanced servicing, including modification logbook and lifelist detailed diagnostics) SIMATIC PDM stand-alone SIMATIC PDM system-integrated Minimum configuration Components for Predefined product configurations individual configuration Product name SIMATIC PDM Single Point SIMATIC PDM Basic SIMATIC PDM Service SIMATIC PDM S7 SIMATIC PDM PCS 7 TAGs included in scope of delivery 1 4 128 128 TAG expansions Cannot be expanded TAG options - 128 TAGs - 512 TAGs - 1024 TAGs - 2048 TAGs and/or PowerPacks PowerPacks - From 128 to 512 TAGs - From 512 to 1024 TAGs - From 1024 to 2048 TAGs - From 2048 to unlimited TAGs 128 Option "Integration in STEP 7/PCS 7" opt opt n n Option "Routing through S7-400" opt opt opt n Option "Communication via standard HART multiplexer" opt opt opt opt n: Components included in delivery of individual PDM configurations opt: Can be ordered as options Note: For definition of TAG, see page 4/15. Minimum configuration SIMATIC PDM Single Point This low-cost minimum configuration with handheld functionality is tailored to processing exactly one field device via a point-topoint coupling. All device functions are supported as defined in the device description. These functions include: 7 Unlimited selection of devices / management of device catalog 7 Communication via PROFIBUS DP/PA or HART modem 7 Parameterization and diagnostics in accordance with the device description 7 Exporting and importing of parameter data 7 Device identification 7 Lifelist 4/14 Siemens ST PCS 7 · November 2007 The following system functions of SIMATIC PDM Basic are not available with SIMATIC PDM Single Point: • EDD-based diagnostics in the lifelist • Project editing • Storage function (only exporting and importing of parameter data) • Recording functions • Routing • Communication with HART field devices via remote I/Os The functions of SIMATIC PDM Single Point cannot be extended (e.g. to SIMATIC PDM Basic or with the routing option through S7-400), nor can it be expanded with TAG options or PowerPacks. © Siemens AG 2007 Engineering system ES software SIMATIC PDM Process Device Manager Predefined product configurations SIMATIC PDM Service This is a predefined product configuration especially for mobile use in servicing for projects with up to 128 TAGs. It offers service engineers all functions of SIMATIC PDM Basic, including modification logbook, calibration report and detailed diagnostics in the lifelist. SIMATIC PDM Service can be expanded by the functional options "Integration in STEP 7/PCS 7", "Routing through S7-400" and "Communication via standard HART multiplexer" as well as by SIMATIC PDM PowerPacks (see under TAG options/ PowerPacks). The following program components are part of SIMATIC PDM Service: • SIMATIC PDM Basic • Option: 128 TAGs SIMATIC PDM PCS 7 SIMATIC PDM PCS 7 is a predefined product configuration for integration into the engineering system (engineering tool set) and the maintenance station of SIMATIC PCS 7. The product version designed for projects with up to 128 TAGs allows the use of all functions of SIMATIC PDM Basic (including modification logbook, calibration report and detailed diagnostics in the lifelist). In addition, it contains the functionality for integration of the SIMATIC PDM into HW-Config as well as the routing from the central engineering system to the field devices. SIMATIC PDM PCS 7 can be expanded by the option "Communication via standard HART multiplexer" and by SIMATIC PDM PowerPacks (see under TAG options/PowerPacks). The following program components are part of SIMATIC PDM PCS 7: • SIMATIC PDM Basic • Option: 128 TAGs • Option: Integration in STEP 7/SIMATIC PCS 7 • Option: Routing through S7-400 SIMATIC PDM S7 SIMATIC PDM S7 is a predefined product configuration tailored to the use of SIMATIC PDM in a SIMATIC S7 configuration environment. It offers all functions of SIMATIC PDM Basic (including modification logbook, calibration report and detailed diagnostics in the lifelist) as well as the functionality for integration of PDM into HW-Config. SIMATIC PDM S7 can be expanded by the functional options "Routing through S7-400" und "Communication via standard HART multiplexer" and by SIMATIC PDM PowerPacks (see under TAG options/PowerPacks). The following program components are part of SIMATIC PDM S7: • SIMATIC PDM Basic • Option: 128 TAGs • Option: Integration in STEP 7/SIMATIC PCS 7 Components for individual configuration SIMATIC PDM Basic SIMATIC PDM Basic can be expanded by functional options and TAG options/PowerPacks. Use of the following functions requires at least 128 TAGs: • Modification logbook • Calibration report • Detailed diagnostics in the lifelist SIMATIC PDM Basic is also available in the form of a rental license for 50 operating hours for low-cost processing of shortterm projects. SIMATIC PDM option: Integration in STEP 7/PCS 7 This option is required for use of SIMATIC PDM within a SIMATIC S7 or SIMATIC PCS 7 project with a local connection to the PROFIBUS. SIMATIC PDM can then be started directly from the hardware project (HW-Config). SIMATIC PDM option: Routing through S7-400 This option is required additive to the option "Integration in STEP7/PCS 7" if SIMATIC PDM is to be used in a central engineering system for SIMATIC PCS 7/S7 with Ethernet bus connection to the automation systems for plant-wide configuration, parameterization, commissioning and diagnostics of field devices. SIMATIC PDM option: Communication via standard HART multiplexer This option permits SIMATIC PDM to use the HART OPC server for communication with HART field devices via HART multiplexers. TAG options/PowerPacks A TAG corresponds to a SIMATIC PDM object, which represents individual field devices or components within a project, e.g. measuring instruments, positioners, switching devices or remote I/Os. TAGs are also relevant for diagnostics with the lifelist of SIMATIC PDM. In this case, TAGs are considered to be all recognized devices with diagnostics capability, whose detailed diagnostics is effected through the device description (EDD). In contrast to PowerPacks, TAG options are only suitable for product configurations on the basis of individual components. Using the SIMATIC PDM TAG options, the basic software SIMATIC PDM Basic can be expanded from 4 TAGs to 128, 512, 1024 or 2048 TAGs, and with the help of an additive PowerPack also to unlimited TAGs. The number of available TAGs can be subsequently increased for all SIMATIC PDM product configurations by means of the SIMATIC PDM PowerPacks. PowerPacks are available for expansion to 512, 1024, 2048 and unlimited TAGs. Demonstration software A demonstration version of SIMATIC PDM is also available. Online communication and storage functions are not available with this version. SIMATIC PDM Basic is the basic component for production of individual SIMATIC PDM configurations from single components. It contains all functions required for operation and parameterization of the devices, as well as enabling for the following communication modes: • PROFIBUS DP/PA, • HART communication (modem, RS 232 and PROFIBUS), • Modbus, • SIREC bus and • SIPART DR. Without TAG expansion, SIMATIC PDM Basic can manage projects with up to 4 TAGs, and can be used - with observation of the system requirements - for stand-alone operation on any computer (PC/notebook) with local connection to bus segments or with direct connection to the device. Siemens ST PCS 7 · November 2007 4/15 4 © Siemens AG 2007 Engineering system ES software SIMATIC PDM Process Device Manager ■ Function Graphical user interface The GUI of SIMATIC PDM satisfies the requirements of the directives VDI/VDE GMA 2187 and IEC 65/349/CD. Even complex devices with several hundred parameters can thus be represented clearly and processed quickly. Using SIMATIC PDM it is very easy to navigate in highly complex stations such as remote I/Os and even connected field devices. 4 Parameter view of SIMATIC PDM with trend curve and online display Core functions • Adjustment and modification of device parameters • Comparing (e.g. project and device data) • Plausibility testing of data input • Device identification and testing • Device status indication with operating modes, alarms and states • Simulation • Diagnostics (standard, detailed) • Management (e.g. networks and PCs) • Export/import (parameter data, reports) • Commissioning functions, e.g. measuring circuit tests of device data • Device replacement (lifecycle management) • Global and device-specific modification logbook for user operations (audit trail) • Device-specific calibration reports • Graphic presentations of echo envelope curves, trend displays, valve diagnosis results etc. • Presentation of incorporated manuals • Document manager for integration of up to 10 multimedia files Support of system management SIMATIC PDM supports the operative system management in particular through: • Uniform presentation and operation of devices • Indicators for preventive maintenance and servicing • Detection of changes in the project and device • Increasing the operational reliability • Reducing the investment, operating and maintenance costs • Graded user privileges including password protection PDM lifelist with status and diagnostics display 4/16 Siemens ST PCS 7 · November 2007 Several views are available to users to help them with their tasks: • Hardware project view • Process device network view (preferably for stand-alone application) • Process device plant view as TAG-related view, also with display of diagnostics information • Parameter view for parameterizing the field devices • Lifelist view for commissioning and service Communication SIMATIC PDM supports several communication protocols and components for communicating with devices that have the following interfaces: • PROFIBUS DP/PA interface • HART interface • Modbus interface • Special interface from Siemens Further communication protocols on request. Routing From the central engineering system of the SIMATIC PCS 7 process control system, you can navigate with SIMATIC PDM through the various bus systems and remote I/Os down to the connected devices. By means of this routing functionality, every device in the plant which can be parameterized per EDD can be processed. The following processing functions are available: • Read diagnostics information from the device • Modify device settings • Adjust and calibrate devices • Monitor process values • Create simulation values • Reparameterize devices. © Siemens AG 2007 Engineering system ES software SIMATIC PDM Process Device Manager ■ Integration ■ Technical specifications Device Integration Requirements for stand-alone operation SIMATIC PDM supports all devices described by EDD (Electronic Device Description). EDD is standardized to EN 50391 and IEC 61804. Internationally it is the most widely used standardized technology for device integration. At the same time it is the directive of the established organizations for PROFIBUS (PNO: PROFIBUS International) and HART (HCF: HART Communication Foundation). Hardware • PG/PC/notebook with processor corresponding to operating system requirements • Main memory 256 MB or more • Vacant hard disk 210 MB or more Operating systems (alternative) • Microsoft Windows 2000 Professional SP1 or higher • Microsoft Windows XP Professional SP1/SP2 The devices are directly integrated in SIMATIC PDM through their EDD or the current HCF catalog. In the EDD the device is described in terms of its functions and construction using the Electronic Device Description Language (EDDL) specified by PNO. Using this description, SIMATIC PDM automatically creates its user interface with the specific device data. The current device catalog of SIMATIC PDM covers more than 1200 devices from over 100 manufacturers world-wide. In addition, devices from all manufacturers can be integrated in SIMATIC PDM by simply importing their EDDs. It is thus possible to keep the device range up to date at all times and to add to the number of manufacturers and devices supported by SIMATIC PDM. To permit improved transparency, SIMATIC PDM also allows the creation of project-specific device catalogs. If devices are to be used which cannot be found in the SIMATIC PDM device catalog, we will be glad to help you integrate them. Contact addresses Siemens AG, Automation and Drives, Technical Support Europe Phone: +49 180 50 50 222 Fax: +49 180 50 50 223 E-mail: FPlease fill in a Support Request on the Internet (see below for address) Asia/Pacific Phone: +86 1064 719 990 Fax: +86 1064 747 474 E-mail: adsupport.asia@siemens.com America Phone: +1 423 262 2522 Fax: +1 423 262 2200 E-mail: techsupport.sea@siemens.com Support Request Additional information is available in the Internet under: http://www.siemens.com/automation/support-request Further software components • SIMATIC PDM integrated in STEP 7 STEP 7 V5.1 or higher with ServicePack 6 or higher, order separately Selection and ordering data for SIMATIC PCS 7 applications ■ Selection and Ordering Data SIMATIC PDM PCS 7 V6.0 Complete package for integration into the engineering toolset of the SIMATIC PCS 7 engineering system 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows XP Professional Floating license for 1 user, with • SIMATIC PDM Basic • Option "Integration in STEP 7/PCS 7" • Option "Routing through S7-400" • Option "128 TAGs" Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions; 2 CDs with SIMATIC PDM V6.0 and device library as well as supplementary DVD with Microsoft ServicePacks and tools Order No. 6ES7 658-3LX06-0YA5 PowerPacks SIMATIC PDM PowerPack for expanding the TAGs of SIMATIC PDM PCS 7 V6.0 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows XP Professional Floating license for 1 user Type of delivery: License key disk, certificate of license, terms and conditions • From 128 TAGs to 512 TAGs 6ES7 658-3XB06-2YD5 • From 512 TAGs to 1024 TAGs 6ES7 658-3XC06-2YD5 • From 1024 TAGs to 2048 TAGs 6ES7 658-3XD06-2YD5 • From 2048 TAGs to unlimited TAGs 6ES7 658-3XH06-2YD5 Siemens ST PCS 7 · November 2007 4/17 4 © Siemens AG 2007 Engineering system ES software SIMATIC PDM Process Device Manager ■ Selection and Ordering Data Order No. Demonstration software 4 SIMATIC PDM Demo V6.0 without online communication and storage functionality 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows XP Professional Type of delivery: 2 CDs with SIMATIC PDM V6.0 and device library as well as supplementary DVD with Microsoft ServicePacks and tools 6ES7 658-3GX06-0YC8 SIMATIC PDM Upgrade/Update Service SIMATIC PDM Upgrade from V5.x to V6.0 for all product versions and combinations 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows XP Professional, floating license for 1 user Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions; 2 CDs with SIMATIC PDM V6.0 and device library as well as supplementary DVD with Microsoft ServicePacks and tools 6ES7 651-5CX06-0YE5 SIMATIC PDM Software Update Service Subscription for 1 year with automatic extension Requirement: current software version 6ES7 658-3XX00-0YL8 SIMATIC PDM belongs to the SIMATIC products which can be used both in the context of SIMATIC PCS 7 and in the extended context of Totally Integrated Automation (TIA). Depending on the field of application, SIMATIC PDM is used in various product versions with different functionalities, ordering data and type of delivery. To provide a better overview and to avoid faulty ordering, the special selection and ordering data for SIMATIC PCS 7 are listed separately. Selection and ordering data for TIA applications ■ Selection and Ordering Data Order No. Minimum configuration SIMATIC PDM Single Point SIMATIC PDM Single Point V6.0 for operation and parameterization of one field device; communication via PROFIBUS DP/PA or HART modem, including 1 TAG, cannot be expanded with respect to functions or with TAG option/PowerPack 6 languages (German, English, French, Spanish, Italian, Chinese), executes with Windows 2000 Professional or Windows XP Professional Floating license for 1 user Type of delivery: License key disk, certificate of license, terms and conditions; 2 CDs with SIMATIC PDM V6.0 and device library 4/18 6ES7 658-3HX06-0YA5 Siemens ST PCS 7 · November 2007 ■ Selection and Ordering Data Order No. Predefined SIMATIC PDM V6.0 product configurations for special applications SIMATIC PDM Service V6.0 Complete package for standalone users for servicing, with • SIMATIC PDM Basic V6.0 • Option "128 TAGs" 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows 2000 Professional or Windows XP Professional, floating license for 1 user Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions; 2 CDs with SIMATIC PDM V6.0 and device library as well as supplementary DVD with Microsoft ServicePacks and tools 6ES7 658-3JX06-0YA5 SIMATIC PDM S7 V6.0 Complete package for use in a SIMATIC S7 configuration environment, with • SIMATIC PDM Basic V6.0 • Option "Integration in STEP 7/PCS 7" • Option "128 TAGs" 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows 2000 Professional or Windows XP Professional, floating license for 1 user Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions; 2 CDs with SIMATIC PDM V6.0 and device library as well as supplementary DVD with Microsoft ServicePacks and tools 6ES7 658-3KX06-0YA5 Components for individual configuration SIMATIC PDM Basic V6.0 for operation and parameterization of field devices and components, communication via PROFIBUS DP/PA, HART (modem, RS 232, PROFIBUS) and Modbus, including 4 TAGs 6 languages (German, English, French, Spanish, Italian, Chinese), executes with Windows 2000 Professional or Windows XP Professional Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions; 2 CDs with SIMATIC PDM V6.0 and device library • Floating license for 1 user 6ES7 658-3AX06-0YA5 • Rental license for 50 hours 6ES7 658-3AX06-0YA6 © Siemens AG 2007 Engineering system ES software SIMATIC PDM Process Device Manager ■ Selection and Ordering Data Order No. Integration in STEP 7 / SIMATIC PCS 7 Only required if integration of SIMATIC PDM into HW-Config is to be used 6 languages (German, English, French, Spanish, Italian, Chinese), executes with Windows 2000 Professional or Windows XP Professional Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions • Floating license for 1 user 6ES7 658-3BX06-2YB5 4 • From 128 TAGs to 512 TAGs 6ES7 658-3XB06-2YD5 • From 512 TAGs to 1024 TAGs 6ES7 658-3XC06-2YD5 • From 1024 TAGs to 2048 TAGs 6ES7 658-3XD06-2YD5 • From 2048 TAGs to unlimited TAGs 6ES7 658-3XH06-2YD5 Demonstration software 6ES7 658-3CX06-2YB5 Communication via standard HART multiplexer 6 languages (German, English, French, Spanish, Italian, Chinese), executes with Windows 2000 Professional or Windows XP Professional Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions • Floating license for 1 user Order No. SIMATIC PDM PowerPack for subsequent TAG expansion of all SIMATIC PDM V6.0 product configurations 6 languages (German, English, French, Spanish, Italian, Chinese), executes with Windows 2000 Professional or Windows XP Professional Floating license for 1 user Type of delivery: License key disk, certificate of license, terms and conditions Routing through S7-400 6 languages (German, English, French, Spanish, Italian, Chinese), executes with Windows 2000 Professional or Windows XP Professional Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions • Floating license for 1 user ■ Selection and Ordering Data SIMATIC PDM Demo V6.0 without online communication and storage functionality 6 languages (German, English, French, Spanish, Italian, Chinese), executes with Windows 2000 Professional or Windows XP Professional Type of delivery: 2 CDs with SIMATIC PDM V6.0 and device library 6ES7 658-3GX06-0YC8 SIMATIC PDM Upgrade/Update Service 6ES7 658-3EX06-2YB5 TAG options / PowerPacks SIMATIC PDM TAG option for TAG expansion, additive to SIMATIC PDM Basic V6.0 6 languages (German, English, French, Spanish, Italian, Chinese), executes with Windows 2000 Professional or Windows XP Professional Floating license for 1 user Type of delivery: License key disk, certificate of license, terms and conditions • Up to 128 TAGs 6ES7 658-3XA06-2YB5 • Up to 512 TAGs 6ES7 658-3XB06-2YB5 • Up to 1024 TAGs 6ES7 658-3XC06-2YB5 • Up to 2048 TAGs 6ES7 658-3XD06-2YB5 SIMATIC PDM Upgrade from V5.x to V6.0 for all product versions and combinations 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows 2000 Professional or Windows XP Professional, floating license for 1 user Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions; 2 CDs with SIMATIC PDM V6.0 and device library 6ES7 651-5CX06-0YE5 SIMATIC PDM Software Update Service Subscription for 1 year with automatic extension Requirement: current software version 6ES7 658-3XX00-0YL8 Siemens ST PCS 7 · November 2007 4/19 © Siemens AG 2007 Engineering system Engineering Process Safety Introduction ■ Overview Operator system Maintenance station Engineering system Ethernet 4 Industrial Fail-safe, fault-tolerant and high-availability High-availability ET 200M redundant/ nonredundant ET 200M redundant/ nonredundant Standard ET 200iSP redundant/ Standard nonredundant ET 200S ET 200iSP redundant/ nonredundant ET 200S Standard TÜV Standard/ safety-related Standard TÜV Standard/ safety-related Common engineering system for basic process control system and safety instrumented system The process industry frequently features complex technological sequences with high safety demands, and faults and failures in the process automation could have fatal consequences for personnel, machines, plants and the environment. Therefore process safety is of particular significance. The safety technology used must reliably detect errors in the process and also its own internal errors, and automatically set the plant/application to a safe state if an error is detected. 4/20 Siemens ST PCS 7 · November 2007 Safety Integrated for Process Automation is the comprehensive range of products and services from Siemens for safe, fault-tolerant applications in the process industry. This is characterized by: • AS 412F/FH, AS 414F/FH and AS 417F/FH safety-related automation systems • Failsafe PROFIBUS communication using the PROFIsafe profile • Failsafe transmitters (SITRANS P DS III) on the PROFIBUS PA with PROFIsafe • ET 200M and ET 200S distributed I/O systems with safetyrelated I/O modules • User-friendly process visualization via the operator system, including safety-relevant fault messages • Engineering system with S7 F Systems software package, CFC and SIMATIC Safety Matrix • Safety lifecycle management with support of highly qualified solution partners: services for all phases of the lifecycle of a safety instrumented system (analysis, implementation and operation) © Siemens AG 2007 Engineering system Engineering Process Safety Introduction ■ Benefits Safety Integrated for Process Automation permits complete integration of safety engineering into the SIMATIC PCS 7 process control system. The Basic Process Control System (BPCS) and Safety Instrumented System (SIS) melt together into a uniform and innovative complete system. The advantages of this fusion are quite clear: • One common controller platform • One common engineering system • No separate safety bus - standard and safety-related communication take place on the same fieldbus (PROFIBUS with PROFIsafe) • Mixed operation of standard and safety-related I/O modules in ET 200M and ET 200S remote I/O stations • Uniform data management - no complex data exchange between BPCS and safety system • Integration of safety-related applications into process visualization on the operator station • Automatic integration of safety-related fault messages with time tagging into the process control system • Integration of safety-related hardware into the SIMATIC PCS 7 asset management for diagnostics and preventive maintenance The SIMATIC PCS 7 engineering system is a universal tool equally suitable for BPCS and safety applications. Using the S7 F Systems engineering tool, you can parameterize the AS 414F/FH and AS 417F/FH automation systems as well as the safety-related F-modules of the ET 200M and ET 200S I/O systems. Using Continuous Function Chart (CFC) and predefined function blocks from the F-block library of S7 F Systems, you can configure safety-related applications simply, efficiently and without weary acquaintance. However, this is even simpler, more convenient and faster using the SIMATIC Safety Matrix based on CFC. The configuration tool functioning according to the principle of a Cause&Effect matrix automatically creates complex safety programs once you have assigned the events (causes) occurring during a process to exactly defined reactions (effects). Siemens ST PCS 7 · November 2007 4/21 4 © Siemens AG 2007 Engineering system Engineering Process Safety Engineering F/FH systems ■ Overview ■ Selection and Ordering Data 4 The engineering tool S7 F Systems integrated in the SIMATIC Manager can be used to configure an F system (F/FH). With this tool you can: • Parameterize CPU and F-signal modules • Create safety-related applications in the CFC. Predefined, TÜV-approved blocks are available for this purpose. The safety-related blocks save the user having to perform redundant programming for detecting and reacting to errors. ■ Configuration S7 F Systems supports configuration by means of functions for • Comparison of safety-related F-programs • Recognition of changes in the F-program using the checksum • Separation of safety-related and standard functions. Access to the F-functions can be password-protected. The F-block library integrated in S7 F Systems contains predefined function blocks for generation of safety-related applications with the CFC or the SIMATIC Safety Matrix based on it. The certified F-blocks are extremely robust and intercept programming errors such as division by zero or out-of-range values. They avoid the need for diverse programming tasks for detecting and reacting to errors. 4/22 Siemens ST PCS 7 · November 2007 Order No. S7 F Systems V6.0 Programming and configuration environment for creating and using safety-related STEP 7 programs for a target system based on S7-400H 2 languages (German, English), executes with Windows XP Professional SP2, Windows Server 2003 SP1/SP2 and Windows 2000 SP4, floating license for 1 user Type of delivery: Certificate of license as well as software and electronic documentation on CD 6ES7 833-1CC01-0YA5 S7 F Systems Upgrade from V5.x to V6.0 2 languages (German, English), executes with Windows XP Professional SP2, Windows Server 2003 SP1/SP2 and Windows 2000 SP4, floating license for 1 user Type of delivery: Certificate of license as well as software and electronic documentation on CD 6ES7 833-1CC01-0YE5 Note: With a S7 F Systems Upgrade from V5.x to V6.0, the type of S7 F Systems license changes from single license to floating license. ■ Options S7 F ConfigurationPack When using the safety-related SM 326F/336F I/O modules (AI, DI, DO) as standard I/Os (without F-functionality), an S7 F ConfigurationPack is required for engineering. This is included in S7 F Systems V6.0, and is also available on the Internet for downloading. Additional information is available in the Internet under: http://support.automation.siemens.com/WW/view/de/15208817 © Siemens AG 2007 Engineering system Engineering Process Safety SIMATIC Safety Matrix ■ Overview The SIMATIC Safety Matrix which can be used in addition to the CFC is an innovative safety lifecycle tool from Siemens that can be used not only for user-friendly configuration of safety applications, but also for their operation and service. The tool, which is based on the proven principle of a cause & effect matrix, is ideally suited to processes where defined statuses require specific safety reactions. The SIMATIC Safety Matrix not only means that programming of the safety logic is significantly simpler and more convenient, but also much faster than in the conventional manner. During the risk analysis of a plant, the configuration engineer can assign exactly defined reactions (effects) to events (causes) which may occur during a process. ■ Benefits The advantages of the SIMATIC Safety Matrix in the implementation phase: 7 Simple programming using Cause&Effect method 7 No programming knowledge required 7 Automatic generation of CFCs including driver blocks 7 Automatic version tracking 7 integrated change tracking 7 1-to-1 printout of Cause&Effect matrix ■ Design In the context of SIMATIC PCS 7, the following individual products are offered for the SIMATIC Safety Matrix: • SIMATIC Safety Matrix Tool for configuration of safety functions on the SIMATIC PCS 7 engineering system • SIMATIC Safety Matrix Editor for creating and debugging the Safety Matrix logic in an external computer, independent of the engineering system (can be optionally used additive to the SIMATIC Safety Matrix Tool) • SIMATIC Safety Matrix Viewer for SIMATIC PCS 7 for operation and monitoring of the SIMATIC Safety Matrix using the SIMATIC PCS 7 operator system (for ordering data, refer to page 5/15) System requirements Hardware requirement Software requirement SIMATIC Safety Matrix SIMATIC PCS 7 Tool AS 412H/F/FH, AS 414H/F/FH or AS 417H/F/FH (S7 F Systems RT license is integrated in the case of F/FH systems) SIMATIC PCS 7 V6.0 SP2 or higher, S7 F Systems V5.2 HF 2 or higher with S7 F-Lib V1.2 SIMATIC Safety Matrix Editor Windows 2000 Professional SP2 or higher or Windows XP Professional SIMATIC Safety Matrix SIMATIC PCS 7 AS 412H/F/FH, Viewer AS 414H/F/FH or AS 417H/F/FH (S7 F Systems RT license is integrated in the case of F/FH systems) SIMATIC PCS 7-OS V6.0 SP2 or higher The SIMATIC Safety Matrix Editor offers the advantage that the Safety Matrix can also be created, processed further and debugged outside the SIMATIC PCS 7 engineering system. The SIMATIC Safety Matrix Editor can be used on a computer with Windows 2000 Professional SP2 or higher or Windows XP Professional. However, generation of the safety-related CFC program as well as compilation and downloading to the automation system are only possible by means of the SIMATIC engineering system with the SIMATIC Safety Matrix Tool. Siemens ST PCS 7 · November 2007 4/23 4 © Siemens AG 2007 Engineering system Engineering Process Safety SIMATIC Safety Matrix ■ Function ■ Selection and Ordering Data 4 Safety Matrix: intersections define the linking of causes and effects Order No. SIMATIC Safety Matrix Tool Creation, configuration, compilation, loading and online monitoring of the Safety Matrix in a SIMATIC PCS 7 environment Including SIMATIC Safety Matrix Viewer for SIMATIC PCS 7, for operation and monitoring of the Safety Matrix in a SIMATIC PCS 7 environment with several operator control levels 1 language (English), executes with Windows XP Professional, floating license for 1 user Type of delivery: Certificate of license and authorization diskette for Safety Matrix Tool and Safety Matrix Viewer; software and electronic documentation on CD 6ES7 833-1SM00-0YA5 C) SIMATIC Safety Matrix Editor Creation and checking of the Safety Matrix logic on an external computer without a SIMATIC PCS 7/ STEP 7 environment 1 language (English), executes with Windows 2000 Professional or Windows XP Professional, floating license for 1 user Type of delivery: Certificate of license and authorization diskette; software and electronic documentation on CD 6ES7 833-1SM40-0YA5 C) C) Subject to export regulations: AL: N, ECCN: EAR99S Configuration of analog or digital causes and their digital effects The matrix table is comparable with a spreadsheet program, and the configuration engineer first enters the possible process events (inputs) in the horizontal lines, and then configures their type and number, logical links, possible delays and interlocks, and any tolerable faults. In the vertical columns, he subsequently defines the reactions (outputs) to a particular event. Events and reactions are linked simply by clicking the cell at the intersection of the row and column. Using these data, the SIMATIC Safety Matrix automatically generates complex, safetyrelated CFC programs. No special programming knowledge is required of the configuration engineer, and he can completely concentrate on the safety requirements of the plant. 4/24 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Engineering system Engineering Process Safety SIMATIC PCS 7 Safety ES Packages ■ Overview The SIMATIC PCS 7 standard engineering software can be ordered together with software components for engineering the integrated safety technology as low-cost all-in-one packages. Their composition depends on the application of the SIMATIC PCS 7 Engineering Station: • A combined engineering/operator station for small applications (productive operation as an operator station is possible) • Exclusive engineering station without limitation of quantities (cannot be used for productive operation as an operator station) The engineering software for basic process control and safety applications can now be ordered using one single Order No. An engineering station can also be subsequently extended using S7 F Systems and SIMATIC Safety Matrix Tool using the SIMATIC PCS 7 Safety Matrix ES Extension Package. ■ Selection and Ordering Data Order No. SIMATIC PCS 7 Safety ES Packages SIMATIC PCS 7 Safety ES Package for AS/OS Executes with Windows XP Professional, floating license for 1 user Combination of S7 F Systems, 2 languages (German, English) and SIMATIC PCS 7 Engineering Software AS/OS, 6 languages (German, English, French, Italian, Spanish, Chinese) 4 • 250 POs incl. AS/OS Engineering and Runtime licenses for 250 POs 6ES7 651-6AA07-0YA5 • Unlimited POs incl. AS/OS Engineering license for unlimited POs and AS Runtime license for 600 POs (2-hour OS test mode possible) 6ES7 651-6AF07-0YA5 SIMATIC PCS 7 Safety Matrix ES Package for AS/OS Executes with Windows XP Professional, floating license for 1 user Combination of S7 F Systems, 2 languages (German, English) SIMATIC Safety Matrix Tool, 1 language (English) SIMATIC PCS 7 Engineering Software AS/OS, 6 languages (German, English, French, Italian, Spanish, Chinese) • 250 POs incl. AS/OS Engineering and Runtime licenses for 250 POs 6ES7 651-6BA07-0YA5 • Unlimited POs incl. AS/OS Engineering license for unlimited POs and AS Runtime license for 600 POs (2-hour OS test mode possible) 6ES7 651-6BF07-0YA5 SIMATIC PCS 7 Safety Matrix ES Extension Package Executes with Windows XP Professional, floating license for 1 user Combination of: S7 F Systems, 2 languages (German, English) SIMATIC Safety Matrix Tool, 1 language (English) 6ES7 651-6BX07-0YA5 Siemens ST PCS 7 · November 2007 4/25 © Siemens AG 2007 Engineering system Simulation Simulation with S7-PLCSIM ■ Overview ■ Function S7-PLCSIM simulates a SIMATIC S7 CPU with the associated process images. The program to be tested is loaded into the simulated S7 CPU in a manner identical to the procedure with real hardware, and is executed there. S7-PLCSIM is completely integrated in STEP 7. Process data can be exchanged between S7-PLCSIM and other Windows applications via an interface. OS clients/ multi-clients 4 OS server AS simulation with S7-PLCSIM Automation systems PROFIBUS DP PROFIBUS PA Fieldbus simulation with SIMBApro FAT ET 200M Field devices ■ Selection and Ordering Data Order No. S7-PLCSIM V5.4 Functional testing of programs which were created with CFC/SFC, on PC/PG 5 languages (German, English, French, Italian, Spanish), executes with Windows 2000 Professional or Windows XP Professional, floating license for 1 user Type of delivery: Authorization diskette, certificate of license, terms and conditions; software and electronic documentation on CD • S7-PLCSIM V5.4 6ES7 841-0CC05-0YA5 • S7-PLCSIM upgrade from V3.x, V4.x, V5.0, V5.2 or V5.3 to V5.4 6ES7 841-0CC05-0YE5 S7-PLCSIM Software Update Service Subscription for 1 year with automatic extension; requirement: current software version 6ES7 841-0CA01-0YX2 For further programs concerning testing and simulation, see the catalog "Add Ons for the SIMATIC PCS 7 Process Control System". Dynamic Plant simulation with SIMIT Overview of simulation software for SIMATIC PCS 7 Using the S7-PLCSIM simulation software, user programs created with CFC/SFC can be tested on a PG/PC, regardless of whether the target hardware is available. The detection and elimination of errors is thus brought forward into an early phase of development. This results in faster commissioning, lower costs and better program quality. 4/26 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Operator system 5/2 Introduction 5/4 5/4 5/6 5/8 OS hardware Introduction OS basic hardware Signal output 5/9 5/9 5/12 OS software Introduction OS standard software for single station/server/client SFC Visualization SIMATIC PCS 7 Safety Matrix OS Packages 5/14 5/15 5/16 5/16 Redundant operator systems OS redundancy 5/19 5/19 5/20 5/21 OS archiving Introduction OS short-term archiving OS long-term archiving with StoragePlus OS long-term archiving with Central Archive Server 5/23 5/25 5/25 5/27 5/27 Operation and monitoring via Web SIMATIC PCS 7 Web server Data exchange with host systems OpenPCS 7 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Operator system Introduction ■ Overview ■ Benefits 7 7 7 7 5 7 7 7 User interface of the OS process control system with freely positionable windows The operator system of the SIMATIC PCS 7 process control system permits user-friendly and secure execution of the process by the operating personnel. The operator can observe the process sequence by means of various views and intervene to control the system when necessary. The operator system architecture is extremely variable and can be flexibly adapted to different plant architectures and customer requirements. The basis is formed by perfectly coordinated operator stations for single-user systems (OS single stations) and for multi-user systems with client/server architecture. The system software of the operator stations is available in different levels based on the number of process objects (PO) used: • 250, 1000, 2000, 3000 or 5000 POs per OS single station • 250, 1000, 2000, 3000, 5000 or 8500 POs per OS server (with client/server architecture) The number of POs for an operator station can be increased up to 5000 (OS single station) or 8500 (OS server) at any time by means of PowerPacks to allow for higher requirements or system expansions. 5/2 Siemens ST PCS 7 · November 2007 7 7 7 7 7 7 7 7 Flexible, modular architecture with scalable hardware and software components for single-user and multi-user systems High-performance operated stations based on standard PC technology with Microsoft Windows XP Professional / Server 2003, can be used in office or industrial environments Client/server multi-user systems with up to 12 OS servers/ pairs of servers, each for 8500 process objects (PO) and up to 32 OS clients per server/pair of servers High-performance archive system based on Microsoft SQL server with cyclic archives and integral data backup, optionally with long-term archiving via StoragePlus/central archive server (CAS) OS health check for monitoring important server applications Integration of modifications without interrupting runtime operations, and online testing through selective loading of redundant servers Optimized AS/OS communication: data transmission only following change in data, independent of AS reply cycle; suppression of nuisance alarms User-friendly process control and high operational reliability, also in conjunction with multi-screen technology Extended status displays through combination of status and analog values with alarm information Alarm suppression during startup or on malfunction of a sensor/actuator Dynamic or manual hiding of visual and acoustic alarms that are unimportant depending on the plant status, e.g. during plant startup (however, all messages are recorded and archived); with manual hiding, the duration until display takes place again can be set. Alarm priorities as additional attribute for filtering important messages Central user management, access control, electronic signature Sign-of-life monitoring for subordinate systems connected to the plant bus System-wide time synchronization based on UTC (Universal Time Coordinated) © Siemens AG 2007 Operator system Introduction ■ Technical specifications Definitions Process object (PO) OS variable Licensing OS quantity framework A process object (PO) is a synonym for an operable and observable block with approx. 30 to 50 individual OS variables (parameters). Thus the quantity framework data of the engineering system can be compared with those of the operating system. An OS variable or parameter is a defined memory location required for operating and monitoring with the operator system; values can be written into it and read from it (e.g. setpoint, actual value etc.). A PO usually has several OS variables (which can be operated and monitored). As of SIMATIC PCS 7 V7.0, the OS software will only be licensed on the basis of POs. This significantly simplifies calculation of the required license. An average of 50 OS variables will be calculated for a PO, where motors, valves etc. require fewer variables, and controls, dosing functions etc. require more variables. Checking of the license will also be carried out using the POs, and additionally includes checking of the total number of OS variables used. Every block fulfilling the following criteria is counted and calculated as a PO: • It is not a driver block. • It can be operated and monitored. • It can send messages. Process objects OS variables (approx.) 250 12500 1000 50000 2000 100000 3000 150000 5000 250000 8500 425000 Max. number of OS servers / pairs of servers 12 Max. number of automation systems per OS server / pair of servers 64 Max. number of OS clients in multiclient mode 1) (per multi-user system) 32 Max. number of monitors per operator station with multi-channel operation 4 Max. number of OS areas 64 Max. number of windows per monitor 1 to 16 (adjustable) Number of trends per trend window 10 Selection time for OS area display (100 process symbols) <2s 5 Max. number of process objects: • Per OS single station 5000 POs • Per OS server 8500 POs Max. number of configurable messages per server/single station 150.000 Number of process tags • Per OS single station Approx. 3000 • Per OS server Approx. 5000 • Per multi-user system Approx. 60000 Integral high-performance archive system (cyclic buffer), based on Microsoft SQL server, for: • Process value archiving (per OS server / single station) Approx. 1000/s • Message archiving (per OS server / single station) Steady-state load approx. 10/s Message peak approx. 3000 / 4 s Long-term archiving • Process value archiving with StoragePlus - Process values of one server Approx. 1000/s - Process values of all servers Approx. 1600/s • Process value archiving with central archive server (CAS) 1) Process values from up to 4 single stations, servers or pairs of servers Process values from up to 11 servers or pairs of servers - Process values of one server Approx. 1000/s - Process values of all servers Approx. 10000/s If every OS client has access to all OS servers/pairs of servers Siemens ST PCS 7 · November 2007 5/3 © Siemens AG 2007 Operator system OS hardware Introduction ■ Overview ■ Design Single-user system (OS single station) In a single-user system architecture, all operation and monitoring functions for a complete project (plant/unit) are concentrated in one station. A 10/100/1000 Mbit/s Ethernet RJ45 port is already onboard and can be used for connecting to an OS LAN (terminal bus). The OS single station can be linked to the Industrial Ethernet plant bus by means of two different network connections: • CP 1613 A2 communications processor, for communication with max. 64 automation systems • Standard FastEthernet network card and Basic Communication Ethernet for communication with max. 8 automation systems (not faulttolerant systems) 5 All operator stations are based on modern SIMATIC PCS 7 industrial workstations optimized for use as OS single station, OS client or OS server. The SIMATIC PCS 7 industrial workstations are characterized by powerful PC technology combined with the Microsoft Windows XP Professional or Server 2003 operating system. They can be used in harsh industrial environments or also in offices. Standard components and interfaces from the PC world offer generous scope for system-, customer- or sector-specific options and expansions. The connection of as many as 4 process monitors via an optional multi-VGA graphics card in the OS single station or in the OS client permits the user-friendly control of several plant areas from one operator station. The OS single station can be operated on the plant bus in parallel with other single-user systems or with a multi-user system architecture. Two OS single stations can, however, also be operated redundantly (SIMATIC PCS 7 single station redundancy). Multi-user system with client/server architecture A multi-user system consists of operator terminals (OS clients), which receive data (project data, process values, archives, alarms and messages) from one or more OS servers through an OS LAN (terminal bus). The OS LAN can share the transmission medium with the plant bus or it can be designed as a separate bus (Ethernet with TCP/IP). Central Archive Server (CAS) OS clients (max. 32 in multi-client mode) OS servers (max. 12 redundant) Industrial Ethernet Automation systems In this architecture, redundant OS servers may be set up to meet higher availability requirements. Critical applications running on the OS server are monitored by Health Check for software faults. If a fault is detected, switchover to the redundant system is triggered. Synchronization of the redundant OS servers takes place automatically and at high speed. OS clients can access the data of not only one OS server/server pair, but from several OS servers/pairs of servers simultaneously (multi-client mode). This makes it possible to divide a plant into technological units and to distribute the data accordingly to several OS servers/pairs of servers. In addition to scalability, the advantage of distributed systems is the ability to decouple plant areas from each other, which results in higher availability. 5/4 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Operator system OS hardware Introduction SIMATIC PCS 7 supports multi-user systems with up to 12 OS servers or 12 redundant OS pairs of servers. In multiclient mode, OS clients can access data from one or more of the 12 OS servers/pairs of servers in parallel (up to 32 OS clients simultaneously on all). The OS servers are designed in addition with client functions which permit them to access the data (archives, messages, tags, variables) from the other OS servers of the multi-user system. This means that process graphics on one OS server can also be linked with variables on other OS servers (area-independent displays). Like the OS single stations, the OS servers can be connected to the Industrial Ethernet plant bus using a CP 1613 communications processor or a standard FastEthernet card with Basic Comunication Ethernet (BCE). A 10/100/1000 Mbit/s Ethernet RJ45 port is already onboard and can be used for connecting to an OS LAN (terminal bus). The CP 1613 communication integrated in the IE version of the ES/OS single station and the OS server is a combination of CP 1613 communications processor and S7-1613 communications software. When using fault-tolerant automation systems, the SIMATIC PCS 7 Workstation requires the S7-REDCONNECT software instead of the S7-1613 communications software. The S7-REDCONNECT Upgrade is suitable for upgrading the communications software (for ordering data, see page 9/28). OS archiving The operator system already includes a high-performance archiving system based on Microsoft SQL Server with cyclic archives for short-term saving of process values and messages/ events (alarms). This short-term archive can be combined with a long-term archive on the basis of StoragePlus or the central archive server (CAS). The StoragePlus provided for the bottom performance range is able to archive approx. 1600 process values/s from a total of 4 single stations/servers/pairs of servers. The powerful CAS satisfies much higher requirements. It can be configured as a single server or as a redundant pair of servers, and can archive approx. 10000 values/s from up to 11 servers/pairs of servers. The data managed in StoragePlus and in the CAS can be saved on all storage media supported by the operating system. This requires additional hardware and software, e.g. a DVD writer with suitable burning software. The StoragePlus computer and the CAS are stations on the OS LAN (terminal bus), and are not connected to the plant bus. When using a SIMATIC PCS 7 Industrial Workstation as the hardware platform, the 10/100/1000 Mbit/s Ethernet RJ45 port already onboard can be used for connecting to the OS LAN. Siemens ST PCS 7 · November 2007 5/5 5 © Siemens AG 2007 Operator system OS hardware OS basic hardware ■ Overview ■ Selection and Ordering Data The complete range of SIMATIC PCS 7 Industrial Workstations is available for configuration of operating systems (see page 2/7). 5 Specially optimized versions of the SIMATIC PCS 7 Industrial Workstation are available for operation as single stations, servers or clients. The operating system and the following ES/OS software of the SIMATIC PCS 7 process control system are already preinstalled when delivered: • Single station: PCS 7 Engineering Software for AS/OS (including OS Runtime software) • Server: PCS 7 OS Software Server • Client: PCS 7 OS Software Client You need the corresponding licenses in order to use the preinstalled SIMATIC PCS 7 software. ■ Technical specifications Detailed technical data for the single station, server and client versions of the SIMATIC PCS 7 Industrial Workstation can be found in Section "SIMATIC PCS 7 Industrial Workstation" of the Chapter "System-neutral components" in tabular format. Order No. OS single station SIMATIC PCS 7 Industrial Workstation, single station version Windows XP Professional MUI operating system (German, English, French, Italian, Spanish, Chinese) • SIMATIC PCS 7 ES/OS 547B BCE WXP Connection to plant bus with Ethernet network card RJ45 (PCI) 10/100/1000 Mbit/s and Basic Communication Ethernet (BCE) for up to 8 automation systems (not H-systems) 6ES7 650-0NF07-0YX0 D) • SIMATIC PCS 7 ES/OS 547B IE WXP Connection to plant bus with CP 1613 A2 communications processor 6ES7 650-0NF07-0YX1 D) • SIMATIC PCS 7 OS Server 547B BCE SRV03 Connection to plant bus with Ethernet network card RJ45 (PCI) 10/100/1000 Mbit/s and Basic Communication Ethernet (BCE) for up to 8 automation systems (not H-systems) 6ES7 650-0NH07-0YX0 D) • SIMATIC PCS 7 OS Server 547B IE SRV03 Connection to plant bus with CP 1613 A2 communications processor 6ES7 650-0NH07-0YX1 D) - without multi-VGA graphics card 6ES7 650-0NG07-0YX0 D) - with Multi-VGA graphics card "2 Screens" 6ES7 650-0NG07-0YA0 D) - with Multi-VGA graphics card "4 Screens" 6ES7 650-0NG07-0YB0 D) OS server SIMATIC PCS 7 Industrial Workstation, server version Windows Server 2003 MUI operating system (German, English, French, Italian, Spanish, Chinese) OS client SIMATIC PCS 7 Industrial Workstation, client version Windows XP Professional MUI operating system (German, English, French, Italian, Spanish, Chinese) • SIMATIC PCS 7 OS Client 547B WXP D) Subject to export regulations: AL: N, ECCN: 5D992B1 5/6 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Operator system OS hardware OS basic hardware ■ Selection and Ordering Data ■ Options Order No. Upgrade from BCE to CP 1613 communication CP 1613 A2 PCI card for connection to Industrial Ethernet, with ITP and RJ45 connections 6GK1 161-3AA01 SIMATIC NET S7-1613/2006 for Industrial Ethernet S7 communication software for CP 1613, can be used with Windows 2000 Professional/2000 Server/ XP Professional/Server 2003 Single license for 1 installation, runtime software, software and electronic manual on CD-ROM, license key on diskette, Class A, 2 languages (German/English) 6GK1 716-1CB64-3AA0 B) Expansion of communication software from S7-1613 to S7-REDCONNECT SIMATIC NET S7-REDCONNECT Upgrade For communication with fault-tolerant AS systems, see page 9/28 The basic hardware referred to may be expanded with the following options, depending on the customer’s particular requirements and whether the hardware is used as OS single station, OS server or OS client, e.g. with: • Hardware and software components for redundant operation • Industrial LCD monitors for office and industry environments (see page 2/17) • Signal module for audible and visual signaling of messages • Chipcard reader for access protection (see page 2/4) Multi-VGA operation with up to 4 process monitors is supported in the OS client by two additional hardware versions: • SIMATIC PCS 7 OS Client 547B WXP with multi-VGA graphics card "2 Screens" and • SIMATIC PCS 7 OS Client 547B WXP with multi-VGA graphics card "4 Screens" OS clients and OS single stations with an integral standard graphic interface module for controlling a process monitor can also be functionally expanded by a multi-VGA graphics card "2 Screens" or "4 Screens" (see page 2/16 for ordering data). Additional and expansion components Upgrading from BCE to CP 1613 communication See page 2/15 OS single stations and OS servers with BCE communication can be subsequently upgraded for communication with CP 1613. Items required: • CP 1613 A2: PCI card for connecting to Industrial Ethernet • SIMATIC NET S7-1613: S7 communications software for CP 1613 B) Subject to export regulations: AL: N, ECCN: EAR99H Note: Ordering data in abbreviated form; for detailed Ordering data, see page 2/14. Siemens ST PCS 7 · November 2007 5/7 5 © Siemens AG 2007 Operator system OS hardware Signal output ■ Overview ■ Selection and Ordering Data Signal module External circuit Acknowledgeable contact •3m 6XV2 175-8AH30 Acknowledgement input • 10 m 6XV2 175-8AN10 • 32 m 6XV2 175-8AN32 • 50 m 6XV2 175-8AN50 Contact channel 1 Contact channel 2 Contact channel 3 OS Single Station and OS Client can be expanded by a signal module. This signal module can operate a horn and up to 3 different lamps or buzzer sounds symbolizing different signal classes. Together with a hardware timer (watchdog) the signal module is able to detect and signal the failure of an operator station. A hardware acknowledge key can also be connected. The signal module occupies one PCI slot in the operator station. 5/8 Order No. 6DS1 916-8RR Connecting cable For connecting an external audio detector to a signal module Driver 5 PCI Signal Module PCI card for installing in an operator station Siemens ST PCS 7 · November 2007 B) Subject to export regulations: AL: N, ECCN: EAR99H B) © Siemens AG 2007 Operator system OS software Introduction ■ Overview OS basic hardware and OS software are structured by OS single station, OS server and OS client in compliance with the architecture of the operator system and are accordingly coordinated in this regard. ■ Design The OS standard software of OS single stations and OS clients can be expanded by SIMATIC PCS 7 SFC Visualization and Safety Matrix Viewer. The high-performance cyclic buffer archiving system integrated as standard in OS single station and OS server for short-term archiving of up to 512 variables can be expanded within the limit of 10000 variables using SIMATIC PCS 7 archive licenses and SIMATIC PCS 7 Archive PowerPacks. The SIMATIC PCS 7 archive licenses (Count Relevant Licenses) are cumulative. SIMATIC PCS 7 Archive PowerPacks permit expansion in steps from 1500 to 5000 or 10000 variables. For ordering data for SIMATIC PCS 7 Archive and SIMATIC PCS 7 Archive PowerPacks, refer to page 5/20. The short-term archive can also be combined with a long-term archive. StoragePlus is available for long-term archiving in the bottom performance range, and the central archive server (CAS) is envisaged for the top performance range. See page 5/19 for details. You can also implement redundant system configurations with OS single stations and OS servers. See page 5/16 for details. The following tables provide a selection aid for ordering an operator station. Depending on whether a redundant or non-redundant design is selected, the tables indicate the respectively required number of • SIMATIC PCS 7 Industrial Workstations, • licenses for OS standards software, and • licenses for optionally used supplementary OS software. Single-user system OS single station with Windows XP Professional operating system Redundancy Without With SIMATIC PCS 7 ES/OS 547B BCE WXP with BCE communication for up to 8 automation systems (not H systems) 1 2 SIMATIC PCS 7 ES/OS 547B IE WXP with Industrial Ethernet communication 1 2 1 2 SIMATIC PCS 7 OS Software Single Station V7.0 1 -- SIMATIC PCS 7 Single Station Redundancy V7.0 including RS 232 connecting cable, 10 m -- 1 SIMATIC PCS 7 SFC Visualization V7.0 1 2 SIMATIC Safety Matrix Viewer for PCS 7 1 2 SIMATIC PCS 7 Archive V7.0/ SIMATIC PCS 7 Archive PowerPack for expansion of short-term cyclic buffer archive 1 2 SIMATIC PCS 7 Industrial Workstation including operating system, alternatives Additional IE communications software for SIMATIC PCS 7 ES/OS 547B IE WXP SIMATIC NET S7-REDCONNECT Upgrade OS standard software Supplementary OS software (optional) Multi-user system with client/server architecture OS server with Windows 2003 Server operating system Redundancy Without With SIMATIC PCS 7 OS Server 547B BCE SRV03 with BCE communication for up to 8 automation systems (not H systems) 1 2 SIMATIC PCS 7 OS Server 547B IE SRV03 with Industrial Ethernet communication 1 2 1 2 SIMATIC PCS 7 OS Software Server V7.0 1 -- PCS 7 Server Redundancy V7.0, including RS 232 connecting cable, 10 m -- 1 1 2 SIMATIC PCS 7 Industrial Workstation including operating system, alternatives Additional IE communications software for SIMATIC PCS 7 OS Server 547B IE SRV03 SIMATIC NET S7-REDCONNECT Upgrade OS standard software Supplementary OS software (optional) SIMATIC PCS 7 Archive V7.0/ SIMATIC PCS 7 Archive PowerPack for expansion of short-term cyclic buffer archive OS client with Windows XP Professional operating system SIMATIC PCS 7 Industrial Workstation including operating system, alternatives Connection for OS-LAN (terminal bus) onboard: SIMATIC PCS 7 OS Client 547B WXP, alternatively with: • onboard standard graphics, • multi-VGA graphics card "2 Screens", or • multi-VGA graphics card "4 Screens" Note on Microsoft SQL Server software The "SQL Server" software from Microsoft delivered with SIMATIC PCS 7 may not be used outside the SIMATIC PCS 7 environment without the written approval of Siemens. 1 OS standard software SIMATIC PCS 7 OS Software Client V7.0 1 Supplementary OS software (optional) SIMATIC PCS 7 SFC Visualization V7.0 1 SIMATIC Safety Matrix Viewer for PCS 7 1 Siemens ST PCS 7 · November 2007 5/9 5 © Siemens AG 2007 Operator system OS software Introduction ■ Function Messages and alarms Graphical user interface The predefined user interface of the operator system has all the features typical of a control system. It is multilingual, clearly structured, ergonomic and easy to understand. Operators can survey the process extremely easily, and rapidly navigate between different views of the plant. The system supports them in this process with hierarchical display structures that can be configured as required. These facilitate the direct selection of lowerlevel areas during process control. 5 Process displays and process tags can also be called up by name. An online language selector permits the user to change the display language during runtime. A standard view and a server view are available for the technological representation of a plant, each with variously designed area overviews. Features provided in both views include: • Message line for display of last message, can be configured such that either the message of the highest class or with the highest priority is shown • Date, time and name of the operator • Area overview with up to 36/49/64 areas (depending on resolution of the process monitor) • Working area for plant displays and movable windows for faceplates, trends, messages etc. • System function keys In a special message view it is possible to switch between control message pages such as new list, old list, cleared alarm list, operator action list, control element list and message history list. Trends Up to 150,000 messages/alarms can be configured per OS single station/OS server. Message priorities are issued as an additional attribute to the known signal classes in order to make it easier to assess large quantities of signals and to be better able to distinguish important messages from the less important. By means of intelligent alarm management, alarms that are of lower importance for the safe and fault-free operation of the plant in certain plant states can be hidden and silenced. These alarms are still logged and archived as before. This saves a noticeable amount of work for the operators. Insignificant alarms can be hidden in two ways: • Dynamically, i.e. depending on preconfigured definition for up to 32 operating states (Smart Alarm Hiding) • Manually, with time limit Operators can specifically disable messages (alarms) from individual process tags or from all process tags of a display/area in the event of faults in a sensor/actuator or during startup. Disabling and enabling are recorded in an input report. Active messages are signaled by group displays representing preconfigured views based on message groups. The group displays also indicate whether messages are disabled or not. The last message to have arrived – or the message with the highest priority when alarm priorities are utilized – is displayed at the top edge of the standard view. A predefined window with further messages can be called up with the "Extended message line". The "Loop-in-alarm" and "Select display using process tag" functions support the quick evaluation and resolution of faults. Using "Loop-in-alarm", the operator can jump directly to the process display with the object which caused the fault, and can then call up the associated faceplate (loop display) through the process tag whose block symbol is colored (cyan). The faceplate window (loop display) can be anchored so that it remains visible even when the display is changed. Flexible setting options for audible output and priorities which can be defined using signal variables additionally support the signaling of messages/alarms through a sound card or by controlling external horns via a signal module. Trend window on the operator station Trends can be displayed as a full-size picture or as a window in the working area, and printed directly. Some trends/trend groups are predefined during plant configuration. In particular for comparisons, standardized curves with percentage scaling can be produced in addition to the absolute display. The standard settings for dimensions and limits (e.g. minimum/maximum) defined during configuration are automatically applied during runtime. At runtime, operators can compose their own trends, select them by process tag name, and save them for reuse. Message window on the operator station 5/10 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Operator system OS software Introduction Central user management, access control and electronic signature Clock synchronization With SIMATIC Logon, the operator system has central user administration with access control that complies with the validation requirements of 21 CFR Part 11. The administrator can divide the users into groups and assign differently defined access rights (roles) to these groups. The operator obtains the specific rights when logging on within the scope of the access control. Apart from the keyboard, an optional chipcard reader, for example, can be used as the logon device. In addition, SIMATIC Logon offers the "electronic signature" function. SIMATIC Logon is already integrated in SIMATIC PCS 7 and need not be ordered separately. For further information on SIMATIC Logon as well as ordering data for an optional chipcard reader, see page 2/5. 5 Sign-of-life monitoring With the "Sign-of-life monitoring" function, the operator system is able to monitor the correct operation of all subordinate systems connected to the plant bus. A graphical plant configuration display shows the status of each monitored component. The SIMATIC PCS 7 asset management offers enhanced functionality in this context (see Chapter "Asset Management"). SICLOCK TM central plant clock Together with a SICLOCK time generator (see Catalog "Add Ons for SIMATIC PCS 7"), the operator system of the SIMATIC PCS 7 process control system can implement the system-wide synchronization on the basis of UTC (Universal Time Coordinated). This feature is especially beneficial for widely distributed plants present in different time zones, e.g. pipelines. Script languages Visual Basic and C are the scripting languages available for custom programming of OS applications. Siemens ST PCS 7 · November 2007 5/11 © Siemens AG 2007 Operator system OS software OS standard software for single station/server/client ■ Overview ■ Selection and Ordering Data The OS standard software is adapted to the SIMATIC PCS 7 Industrial Workstations offered (OS single station, OS server and OS client). The OS standard software for OS single stations and OS servers can be adapted to plants of various size by means of the number of process objects (PO). The number of POs can be increased at any time by adding more PowerPacks in order to allow for higher requirements of system expansions. 5 You can also implement redundant system configurations with OS single stations and OS servers. See page 5/16 for details. The engineering of the SIMATIC PCS 7 process control system is usually concentrated in a separate engineering system. In the case of OS single stations used for small plants, engineering and operator functionality can be combined in one station, except with redundant systems (for engineering software, see Section "Engineering system"). Order No. OS Software Single Station SIMATIC PCS 7 OS Software Single Station V7.0 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows XP Professional, single license for 1 installation Electronic documentation on PCS 7 toolset DVD Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions; PCS 7 V7.0 toolset DVDs, Microsoft SQL Server 2005 including EULA and supplementary CDs/DVDs (e.g. Microsoft ServicePacks and tools) The high-performance cyclic buffer archiving system integrated as standard in OS single station and OS server for short-term archiving of up to 512 variables can be expanded to 1500, 5000 or 10000 variables using SIMATIC PCS 7 Archive PowerPacks. Furthermore, the variables of the SIMATIC PCS 7 archive itself can also be accumulated for the short-term archive within the expansion limit of 10000 variables (Count Relevant Licenses). • 250 POs1) 6ES7 658-2AA07-0YA0 • 1000 POs 6ES7 658-2AB07-0YA0 • 2000 POs 6ES7 658-2AC07-0YA0 • 3000 POs 6ES7 658-2AD07-0YA0 • 5000 POs 6ES7 658-2AE07-0YA0 The short-term archive can also be combined with a long-term archive. See page 5/19 for details. SIMATIC PCS 7 OS Software Single Station PowerPack V7.0 for extending the OS Software Single Station 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows XP Professional, single license for 1 installation Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions The OS standard software of OS single stations and OS clients can be expanded by SFC visualization and the safety matrix viewer. • From 250 POs to 1000 POs 6ES7 658-2AB07-0YD0 • From 1000 POs to 2000 POs 6ES7 658-2AC07-0YD0 • From 2000 POs to 3000 POs 6ES7 658-2AD07-0YD0 • From 3000 POs to 5000 POs 6ES7 658-2AE07-0YD0 1) 5/12 Siemens ST PCS 7 · November 2007 A process object (PO) is a synonym for an operable and observable block with approx. 30 to 50 individual OS variables (parameters). When licensing, an average of 50 OS variables is calculated for one PO. © Siemens AG 2007 Operator system OS software OS standard software for single station/server/client ■ Selection and Ordering Data Order No. ■ Selection and Ordering Data OS Software Server OS Software Client SIMATIC PCS 7 OS Software Server V7.0 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows Server 2003, single license for 1 installation Electronic documentation on PCS 7 toolset DVD Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions; PCS 7 V7.0 toolset DVDs, Microsoft SQL Server 2005 including EULA and supplementary CDs/DVDs (e.g. Microsoft ServicePacks and tools) SIMATIC PCS 7 OS Software Client V7.0 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows XP Professional, floating license for 1 user Electronic documentation on PCS 7 toolset DVD Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions; PCS 7 V7.0 toolset DVDs, Microsoft SQL Server 2005 including EULA and supplementary CDs/DVDs (e.g. Microsoft ServicePacks and tools) • 250 POs 6ES7 658-2BA07-0YA0 • 1000 POs 6ES7 658-2BB07-0YA0 • 2000 POs 6ES7 658-2BC07-0YA0 • 3000 POs 6ES7 658-2BD07-0YA0 • 5000 POs 6ES7 658-2BE07-0YA0 • 8500 POs 6ES7 658-2BF07-0YA0 Order No. 6ES7 658-2CX07-0YA5 5 SIMATIC PCS 7 OS Software Server PowerPack V7.0 for extending the OS Software Server 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows Server 2003, single license for 1 installation Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions • From 250 POs to 1000 POs 6ES7 658-2BB07-0YD0 • From 1000 POs to 2000 POs 6ES7 658-2BC07-0YD0 • From 2000 POs to 3000 POs 6ES7 658-2BD07-0YD0 • From 3000 POs to 5000 POs 6ES7 658-2BE07-0YD0 • From 5000 POs to 8500 POs 6ES7 658-2BF07-0YD0 Siemens ST PCS 7 · November 2007 5/13 © Siemens AG 2007 Operator system OS software SFC Visualization ■ Overview ■ Selection and Ordering Data SIMATIC PCS 7 SFC Visualization V7.0 For displaying and operating SFC sequence controls on an operator station 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows XP Professional or Windows Server 2003, floating license for 1 user Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions 5 The SFC visualization function of the operator system enables you to display and operate the sequence controls configured with the SFC tool in the same way as on the engineering system. No additional configuration work is necessary. In an overview display it is possible, for example, to open step and transition displays and to present step comments or dynamically supplied stepping conditions. 5/14 Siemens ST PCS 7 · November 2007 Order No. 6ES7 652-0XD07-2YB5 © Siemens AG 2007 Operator system OS software SIMATIC PCS 7 Safety Matrix OS Packages ■ Overview Using the SIMATIC Safety Matrix Viewer, you can operate and monitor the SIMATIC Safety Matrix from the SIMATIC PCS 7 OS Single Station or from the SIMATIC PCS 7 OS Client. The SIMATIC Safety Matrix Viewer is available together with the SIMATIC PCS 7 OS software as a low-price SIMATIC PCS 7 Safety Matrix OS Package. The difference is in the SIMATIC PCS 7 OS software which depends on whether the OS Single Station or the OS Client is the target system. By means of the SIMATIC PCS 7 Safety Matrix OS Extension Package, a SIMATIC PCS 7 OS Single Station or a SIMATIC PCS 7 OS Client can be subsequently expanded by the SIMATIC Safety Matrix Viewer. ■ Selection and Ordering Data Order No. SIMATIC PCS 7 Safety Matrix OS Single Station Package Executes with Windows XP Professional, single license for 1 installation Combination of: • SIMATIC PCS 7 OS Software Single Station for 250 POs, 6 languages (German, English, French, Italian, Spanish, Chinese) • SIMATIC Safety Matrix Viewer, 1 language (English) 6ES7 652-6AA07-0YA0 SIMATIC PCS 7 Safety Matrix OS Client Package Executes with Windows XP Professional, floating license for 1 user Combination of: • SIMATIC PCS 7 OS Software Client, 6 languages (German, English, French, Italian, Spanish, Chinese) • SIMATIC Safety Matrix Viewer, 1 language (English) 6ES7 652-6CX07-0YA5 SIMATIC PCS 7 Safety Matrix OS Extension Package Executes with Windows XP Professional, floating license for 1 user comprising: SIMATIC Safety Matrix Viewer, 1 language (English) 6ES7 652-6BX07-0YA5 5 Details on the SIMATIC Safety Matrix as well as information on SIMATIC PCS 7 Safety ES Packages can be found from page 4/20. Siemens ST PCS 7 · November 2007 5/15 © Siemens AG 2007 Operator system Redundant operator systems OS redundancy ■ Overview Client 5 OS-LAN (Ethernet), ring 1 Client OS-LAN (Ethernet), ring 2 Redundant servers Redundant Industrial Ethernet plant bus (double ring) AS 412H/ AS 414H/ AS 417H OS redundancy shown in a client/server architecture with high availability OS single stations and OS servers can have a redundant design if necessary: • A SIMATIC PCS 7 Single Station Redundancy programming package is required to design redundant OS single stations. This contains: - OS Software Single Station - Software WinCC/Redundancy (in each case for two OS single stations) - RS 232 cable connector for optimization of internal communication between the two OS single stations. • A SIMATIC PCS 7 Server Redundancy programming package is required to design redundant OS servers. This contains: - OS Software Server - Software WinCC/Redundancy (in each case for two OS servers) - RS 232 cable connector for optimization of internal serverserver communication. A separate Ethernet connection can be used instead of the serial RS 232 connection for optimization of internal communication between the two redundant stations (OS single stations/OS servers). This is an alternative e.g. with larger distances between the stations or if the COM interface is required elsewhere. An optical or electrical connection can be used depending on the environmental conditions and the distance between the redundant stations, e.g. up to 100 m per crossover network cable with RJ45 connectors. For further information, refer to the Manual "SIMATIC PCS 7 V7.0 fault-tolerant process control systems"; for appropriate cable material and further accessories, refer to Catalog IK PI (Industrial Communication). What further components are required depends on the plant architecture. The design of the plant bus and terminal bus (OS-LAN) is of particular importance, as well as the type and number of subordinate automation systems. The maximum requirements are determined by the redundant configuration shown in the figure with a fault-tolerant automation system and two redundant rings each for the plant bus and terminal bus. ■ Design The following table provides an overview of which components are required for a redundant OS single station or OS pair of servers depending on certain criteria: Up to 8 AS per single 9 to 64 AS per single station/pair of servers station/pair of servers SIMATIC PCS 7 Indus- Incl. Ethernet network card 10/100/1000 Mbit/s trial Workstation, single and BCE station or server verIncl. CP 1613 and S7-1613 software sion, alternatives Min. 1 fault-tolerant AS 2 -- -- 2 (alternative to BCE) 2 2 SIMATIC PCS 7 Single Station/Server Redundancy V7.0 (including RS 232 connecting cable) 1 1 1 S7-REDCONNECT Upgrade Connection to redundant plant bus (2 rings), alternatives -- -- 2 BCE Desktop adapter network card 2 -- -- CP 1613 CP 1613 communications processor 2 (alternative to BCE) 2 2 S7-1613 software 2 (alternative to BCE) 2 -- -- -- 2 2 2 2 S7-REDCONNECT software Connection to redundant terminal bus (2 rings) 5/16 SIMATIC PCS 7 Redundant Terminalbus Adapter Package Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Operator system Redundant operator systems OS redundancy Redundant OS single stations / OS servers with BCE communication Redundant OS single stations / OS servers with CP 1613 communication • FastEthernet card • PCS 7 single station redundancy or PCS 7 server redundancy Plant bus Max. 8 automation systems per single station/pair of servers • CP 1613 • S7-1613 software • PCS 7 single station redundancy or PCS 7 server redundancy Plant bus • CP 1613 • S7-1613 software + Upgrade S7-REDCONNECT • PCS 7 single station redundancy or PCS 7 server redundancy 5 Plant bus Max. 64 automation systems per single station/pair of servers Fault-tolerant systems AS 414H, AS 417H Connection of redundant OS single stations / OS servers on the plant bus Connection to plant bus The operator systems (single stations or servers) communicate with the automation systems via the Industrial Ethernet plant bus. The following special points must be observed for redundant configurations: • BCE communication via Ethernet network card 10/100/1000 Mbit/s is generally also sufficient for redundant operator stations. Up to 8 automation systems can be connected per pair of servers in this manner. • Communication using CP 1613 is only required in the following cases: - Connection of a subordinate fault-tolerant automation system - More than 8 stations are required per OS. • An operator station with CP 1613 is delivered with the S7-1613 software. If a subordinate fault-tolerant automation system is to be connected, the S7-REDCONNECT software is required. In this case, the S7-REDCONNECT upgrade must be ordered. • If an operator station with BCE communication is to be upgraded for operation with a subordinate fault-tolerant automation system, the S7-REDCONNECT software is required in addition to the CP 1613 communications processor. • If the plant bus is to be designed as a redundant dual ring, you require two interface modules (2 x Ethernet network cards 10/100/1000 Mbit/s or 2 x CP 1613) per OS single station / OS server. Connection to terminal bus (OS-LAN) You can connect clients and servers to a non-redundant terminal bus (OS-LAN) using the onboard Ethernet interface or a desktop adapter network card. With a redundant terminal bus where two rings are connected together via two pairs of switches, each station must be connected to both rings using a SIMATIC PCS 7 redundant terminal bus adapter package. The SIMATIC PCS 7 redundant terminal bus adapter package consists of server and desktop adapter network cards (for details on the configuration, refer to the Manual "SIMATIC PCS 7 V7.0 fault-tolerant process control systems"). ■ Selection and Ordering Data Order No. Design of redundant OS single stations SIMATIC PCS 7 Single Station Redundancy V7.0 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows XP Professional, single license for 2 installations with OS Software Single Station and WinCC/Redundancy as well as RS 232 connecting cable, 10 m Type of delivery: 2 license key disks, 2 emergency key disks, certificate of license, terms and conditions; PCS 7 V7.0 toolset DVDs, Microsoft SQL Server 2005 including EULA, supplementary CDs/DVDs (e.g. Microsoft ServicePacks and tools) as well as RS 232 connecting cable, 10 m • 250 POs 6ES7 652-3AA07-2YA0 • 1000 POs 6ES7 652-3AB07-2YA0 • 2000 POs 6ES7 652-3AC07-2YA0 • 3000 POs 6ES7 652-3AD07-2YA0 • 5000 POs 6ES7 652-3AE07-2YA0 PowerPacks for PO expansion See under OS Software Single Station PowerPack V7.0 (2 PowerPacks each required) Siemens ST PCS 7 · November 2007 5/17 © Siemens AG 2007 Operator system Redundant operator systems OS redundancy ■ Selection and Ordering Data ■ Selection and Ordering Data Order No. Design of redundant OS servers 5 SIMATIC PCS 7 Server Redundancy V7.0 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows Server 2003, single license for 2 installations with OS Software Server und WinCC/Redundancy as well as RS 232 connecting cable, 10 m Type of delivery: 2 license key disks, 2 emergency key disks, certificate of license, terms and conditions; PCS 7 V7.0 toolset DVDs, Microsoft SQL Server 2005 including EULA, supplementary CDs/DVDs (e.g. Microsoft ServicePacks and tools) as well as RS 232 connecting cable, 10 m SIMATIC NET S7REDCONNECT/2006 Software for fail-safe S7 communication over redundant networks, for CP 1613, runtime software, in 2 languages (German, English), executes with Windows 2000 Professional/ 2000 Server/ XP Professional/ Server 2003, single license for 1 installation, software and electronic manual on CD-ROM, license key on diskette 6GK1 716-0HB64-3AA0 Upgrading for communication with fault-tolerant AS Starting from OS single stations / OS servers with CP 1613 and S7-1613 software • 250 POs 6ES7 652-3BA07-2YA0 • 1000 POs 6ES7 652-3BB07-2YA0 • 2000 POs 6ES7 652-3BC07-2YA0 • 3000 POs 6ES7 652-3BD07-2YA0 • 5000 POs 6ES7 652-3BE07-2YA0 • 8500 POs 6ES7 652-3BF07-2YA0 SIMATIC NET S7EDCONNECT/2006 Upgrade Software for expansion of S7-1613 to S7-REDCONNECT, runtime software, in 2 languages (German, English), executes with Windows 2000 Professional/ 2000 Server/ XP Professional/ Server 2003, single license for 1 installation, software and electronic manual on CD-ROM, license key on diskette PowerPacks for PO expansion See under OS Software Server PowerPack V7.0 (2 PowerPacks each required) 6GK1 716-0HB64-3AC0 Components for connection of OS single stations/OS servers/OS clients to a redundant terminal bus Individual components for redundancy upgrading with existing OS single stations / OS servers WinCC/Redundancy V6.2 For alignment of archives following OS restart; single license for 2 installations Installation required on each of the two redundant SIMATIC PCS 7 Industrial Workstations 6AV6 371-1CF06-2AX0 RS 232 connecting cable, 10 m 6ES7 902-1AC00-0AA0 SIMATIC PCS 7 Redundant Terminal Bus Adapter Package Server and desktop adapter for designing a redundant terminal bus, consisting of 2 Intel PCI network cards for connection to Industrial Ethernet (10/100/1000 Mbit/s), with RJ45 connection 6ES7 652-0XX01-1XF0 B) Subject to export regulations: AL: N, ECCN: EAR99H Expansion components for OS single stations / OS servers For connection to redundant plant bus (BCE/CP 1613), for upgrading from BCE to CP 1613 including communication with fault-tolerant AS Desktop adapter network card for BCE and as spare part for redundant terminal bus INTEL PCI network card for connection to Industrial Ethernet (10/100/1000 Mbit/s), with RJ45 connection A5E00504378 B) CP 1613 A2 PCI card for connection to Industrial Ethernet, with ITP and RJ45 connections 6GK1 161-3AA01 B) SIMATIC NET S7-1613/2006 for Industrial Ethernet S7 communications software for CP 1613, runtime software, in 2 languages (German, English), executes with Windows 2000 Professional/ 2000 Server/ XP Professional/ Server 2003, single license for 1 installation, software and electronic manual on CD-ROM, license key on diskette 6GK1 716-1CB64-3AA0 5/18 Order No. Communications software when using fault-tolerant AS To be used instead of the S7-1613 software Siemens ST PCS 7 · November 2007 B) © Siemens AG 2007 Operator system OS archiving Introduction The StoragePlus computer and the central archive server are stations on the terminal bus, and are not connected to the plant bus. When using a SIMATIC PCS 7 Industrial Workstation (BCE version) as the hardware platform, the Ethernet interface (Ethernet RJ45 port) already onboard can be used for connecting to the terminal bus. ■ Overview OS server: short-term archiving (cyclic) Process values Slow archiving cycle > 1 min 30 byte/ value e.g. 2 weeks Fast archiving cycle ≤ 1 min e.g. 7 days Automatic saving e.g. daily Central archive server: long-term archiving Max. 30 byte/ value Microsoft SQL server Saving on hard disk e.g. for 6 months Messages/events Alarm archive e.g. 2 months 172 byte/ event Automatic saving (applicative) e.g. weekly Batch server Batch data On user request, transfer following end of a batch XML files Backup archiving on DVD Overview of short-term and long-term archiving The operator system already includes a high-performance archiving system based on Microsoft SQL Server with cyclic archives for short-term saving of process values (typically 1 to 4 weeks) and messages/events (typically 2 months). Data from the short-term archive as well as OS reports and batch data from SIMATIC BATCH can be exported time-controlled or event-controlled for permanent archiving in a long-term archive. ■ Design Two alternatives with different features are available for the OS long-term archiving: • StoragePlus: More economical version for the lower performance range; for the archiving of about 1600 values/s from as many as four single stations, servers or pairs of servers • Central archive server (CAS), for single or redundant configuration: High-performance version for archiving about 10000 values/s from as many as 11 servers or pairs of servers Through a redundant design of the central archive server, the availability of long-term data is increased, and these can also be accessed by the OS clients or the OpenPCS 7 station. SIMATIC BATCH does not yet swap out the batch data to the two central archive servers. However, following automatic matching of the archives, the batch data are available on both central archive servers following swapping out. ■ Function Features of the archive variables and licensing of short-term and long-term archiving • There is only one type of archive variable for OS short-term archiving and CAS long-term archiving. SIMATIC PCS 7 Archive and SIMATIC PCS 7 Archive PowerPacks can be used universally - both for the operator system and for the CAS. • The "SIMATIC PCS 7 Archives" are Count Relevant Licenses, i.e. the archive variables of several licenses are cumulative. Starting with the smallest cumulative number of 1500 variables, any combinations are possible with consideration of the expansion limits of 10000 variables for OS shortterm archiving and 120000 variables for CAS long-term archiving, e.g. 2 x 1500 or 1 x 1500 with 1 x 5000 variables. • The number of archive variables can also be increased using "SIMATIC PCS 7 Archive PowerPacks". Starting with 1500 variables, increasing is possible in steps through 5000, 10000, 30000 and 80000 variables up to 120000 variables. • If a CAS is not used, the licenses of the SIMATIC PCS 7 Archive are installed on the OS single stations and OS servers of the system. Otherwise the installation is only on the CAS. OS single stations and OS servers then "book" their archive variables from the CAS’s stock of variables. It is therefore unnecessary to carry out the complex installation of archive variable licenses on all OS single stations and OS servers in the system. • Operator systems (OS single stations and OS servers) are assigned 512 archive variables each by the OS software, the CAS is immediately provided with 1500 archive variables by the central archive server basic package. If the short-term archiving of the operator systems is combined with the CAS long-term archiving, the 512 archive variables of the OS single stations and OS servers are not cumulated with the 1500 archive variables of the CAS. The 1500 archive variables of the CAS are then available universally for short-term and long-term archiving. • In the case of redundant systems, two archives must be configured with the corresponding number of archive variables. During long-term archiving with StoragePlus, the archived data can be visualized by means of the StoragePlus viewer. Process values and messages exported to the central archive server can also be accessed from an OS client. The data managed in StoragePlus and in the central archive server can be saved on commercially available storage media (e.g. DVD). This requires additional hardware and software which support the respectively used operating system, e.g. a DVD writer with appropriate writer software. Siemens ST PCS 7 · November 2007 5/19 5 © Siemens AG 2007 Operator system OS archiving OS short-term archiving ■ Overview ■ Selection and Ordering Data An integral component of the OS software of OS single stations and OS servers is a high-performance archiving system which can be configured during runtime and which is based on Microsoft SQL server technology. It is used to record process data (typical period 1 to 4 weeks) and messages/events (typical period 2 months) in cyclic archives. 5 The data from the short-term archive as well as OS reports and batch data from SIMATIC BATCH can be exported time-controlled or event-controlled for permanent archiving in StoragePlus or in a central archive server (CAS). Commencing with the 512 archive variables present in the system, the short-term archive for process data can be expanded within the limit of 10000 archive variables with accumulated SIMATIC PCS 7 archives (Count Relevant Licenses) or SIMATIC PCS 7 Archive PowerPacks. The archive variables can be expanded in steps from 1500 to 5000 or 10000 variables using SIMATIC PCS 7 Archive PowerPacks. Further information on licensing, in particular in combination with long-term archiving per CAS,can be found at page 5/19 under "Features of archive variables and licensing of short-term and long-term archiving". 5/20 Siemens ST PCS 7 · November 2007 Order No. Expansion of integral high-performance cyclic buffer archive (512 variables) of OS Single Station and OS Server SIMATIC PCS 7 Archive V7.0 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows XP Professional or Windows Server 2003, single license for 1 installation (Count Relevant License) Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions • 1500 variables 6ES7 658-2EA07-2YB0 • 5000 variables 6ES7 658-2EB07-2YB0 • 10000 variables 6ES7 658-2EC07-2YB0 SIMATIC PCS 7 Archive PowerPack V7.0 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows XP Professional or Windows Server 2003, single license for 1 installation Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions • For expansion from 1500 to 5000 variables 6ES7 658-2EB07-2YD0 • For expansion from 5000 to 10000 variables 6ES7 658-2EC07-2YD0 © Siemens AG 2007 Operator system OS archiving OS long-term archiving with StoragePlus ■ Overview ■ Function OS clients StoragePlus (separate computer) OS-LAN OS server (redundant) Batch server (redundant) Plant bus Automation systems StoragePlus is a program package for long-term archiving of • OS archive data (process values and messages), • OS reports and • batch data of the SIMATIC PCS 7 process control system. StoragePlus manages the process values and messages exported from the OS archives, the OS reports as well as batch data from SIMATIC BATCH in a central database. All these data can be visualized in a graphic and clear manner using the Internet Explorer. ■ Application StoragePlus can be used for long-term archiving of process values and messages, OS reports and SIMATIC BATCH data from up to 4 single stations/servers/pairs of servers of the SIMATIC PCS 7 V7.0 process control system. For this purpose StoragePlus has to be installed on a separate computer with Windows XP Professional oder Windows Server 2003 (see page 2/14) which is connected by terminal bus to the OS and batch servers/single stations of the SIMATIC PCS 7 system. StoragePlus manages the process values, messages and OS reports which are swapped out of the OS archives, as well as batch data from SIMATIC BATCH, in a central database and makes these data available independent of the PCS 7 runtime systems: • All data can be visualized in a graphic and clear manner using the Internet Explorer, selection of the data is selected by integrated filter functions. • Messages and process values can be shown in table form, and process values also in graphic form. • Tables of process values can be exported in CSV format for processing in other Windows applications, e.g. Microsoft Excel. The data managed by StoragePlus and the cataloging can be swapped out onto all commercially available storage media. You require additional hardware and software for this which support the StoragePlus operating system, e.g. DVD writer with appropriate writer software. StoragePlus is able to read in data which were swapped out using StoragePlus V1.0 / V1.1 and to convert the data into the SIMATIC PCS 7 V7.0 (StoragePlus V1.2) data format. Overview of functions • Archiving of messages, process values and reports of the SIMATIC PCS 7 V7.0⋅operator systems • Archiving of batch data from SIMATIC BATCH V7.0 • Cataloging of all StoragePlus data • Swapping out of all StoragePlus data as well as the cataloging onto external storage media • Reading-in of the swapped-out StoragePlus data and cataloging from external storage media • Parameterizing of views (display windows and masks) including the selection criteria for displaying the data • Visualizing of messages in table form dependent on filter functions • Displaying of process values in table or graphic form dependent on filter functions • Exporting of process values in CSV format, e.g. to Microsoft Excel • Visualizing a batch overview (selecting the detailed protocol of a batch from the batch overview is possible) • Web-based presentation of data • Access protection with user-specific rights • Migration of messages and measurement values from StoragePlus V1.0 / V1.1 Siemens ST PCS 7 · November 2007 5/21 5 © Siemens AG 2007 Operator system OS archiving OS long-term archiving with StoragePlus ■ Technical specifications ■ Selection and Ordering Data StoragePlus 5 Long-term archiving Up to 4 single stations, servers or pairs of servers simultaneously Data input for process-value archiving by one server Approx. 1000/s Data input for process-value archiving by all servers Approx. 1600/s Max. data volume input per day 500 MB Hardware requirements Main memory 512 MB or more, 2 GB recommended Hard disk memory recommended • Security EIDE-RAID 1 with 2 hard disks for 80 GB or more • Capacity 2 hard disks for 80 GB or more for separating database and log files Software requirements Operating system / applications • Microsoft Windows XP Professional including SP2 or Windows Server 2003 including SP1 • Microsoft Internet Explorer V6.0 including SP1 • Microsoft Internet Information Services (IIS) and installed Message Queuing Software required for StoragePlus • Microsoft SQL Server 2005 from the scope of delivery of • OS client SIMATIC PCS 7 V7.0 SIMATIC PCS 7; when used for StoragePlus, no additional licenses are • Client software SIMATIC BATCH V7.0 required. 5/22 Siemens ST PCS 7 · November 2007 SIMATIC StoragePlus V1.2 Software for long-term archiving of data from up to 4 single stations, servers or pairs of servers 4 languages (German, English, French, Chinese), executes with Windows XP Professional or Windows Server 2003, single license for 1 installation Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions Order No. 6ES7 652-0XC21-2YB0 © Siemens AG 2007 Operator system OS archiving OS long-term archiving with Central Archive Server ■ Overview ■ Design OS clients OS-LAN OS server (redundant) Batch server (redundant) Central Archive Server (CAS) Plant bus Automation systems The central archive server (CAS) can be used for long-term archiving of • OS archive data (process values and messages), • OS reports and • batch data of the SIMATIC PCS 7 process control system. The process values and messages exported from the OS archives, as well as the OS reports and batch data from SIMATIC BATCH are managed by the CAS in a central database. They can be visualized directly on the OS clients or with the StoragePlus viewer of the CAS. The SIMATIC PCS 7 OS Server (BCE version) with the Microsoft Windows Server 2003 operating system offered in Section "SIMATIC PCS 7 Industrial Workstation" in the Chapter "Systemneutral components" can be used as the basic hardware for the CAS. The OS Software server of the SIMATIC PCS 7 V7.0 process control system is preinstalled on this basic device in addition to the operating system. The Central Archive Server Basic Package is required to configure the CAS. This can be extended to a maximum of 120000 archive variables using SIMATIC PCS 7 Archive/SIMATIC PCS 7 Archive PowerPack licenses. Detailed information on licensing of the CAS in combination with OS short-term archiving can be found at page 5/19 under "Features of archive variables and licensing of short-term and long-term archiving". The CAS does not require a connection to the plant bus. It can be connected to the OS and batch servers of the SIMATIC PCS 7 plant via OS-LAN (terminal bus), e.g. via the integral network connection (Ethernet RJ45 port onboard) of the server. Redundant design of central archive server The CAS can also have a redundant design. This increases the availability of long-term data, and these can also be accessed by the OS clients or the OpenPCS 7 station. SIMATIC BATCH does not yet swap out the batch data to the two central archive servers. However, following automatic matching of the archives, the batch data are available on both central archive servers following swapping out. The following table shows the corresponding number of components required for single and redundant CAS configurations. Single central archive server (CAS) Redundant central archive server (CAS) SIMATIC PCS 7 Industrial Workstation, server version Incl. Ethernet network card and BCE 1 2 Central archive server basic package 1 2 SIMATIC PCS 7 Archives/SIMATIC Licenses for one server PCS 7 Archive PowerPacks for additional archive variables Licenses for two servers WinCC option "Redundancy" -- 1 RS 232 connecting cable, 10 m -- 1 Instead of the serial RS 232 connection, it is also possible to use a separate Ethernet connection for optimization of internal communication between the redundant central archive servers, e.g. as an alternative for larger distances. Siemens ST PCS 7 · November 2007 5/23 5 © Siemens AG 2007 Operator system OS archiving OS long-term archiving with Central Archive Server ■ Function ■ Selection and Ordering Data The central archive server (CAS) can archive approx. 10000 process values/s from as many as 11 servers or pairs of servers of the SIMATIC PCS 7 V7.0 process control system. It is configured in a SIMATIC PCS 7 project like other stations of the SIMATIC PCS 7 process control system (e.g. OS server, batch server, route control server, all clients or OpenPCS 7 station). 5 The process values and messages managed in the database of the CAS can be visualized clearly on the OS clients. The StoragePlus Viewer of the CAS can be used for data visualization on the OS single station. Data selection is supported by integrated filter functions. Messages and process values can be shown in table form, and process values also in graphic form. Tables of process values can be exported in CSV format for processing in other Windows applications, e.g. Microsoft Excel. The data managed by CAS and the cataloging can be swapped out onto all commercially available storage media. This requires additional hardware and software which support the CAS operating system, e.g. a DVD writer with appropriate writer software. Swapping-out can be initiated either by an operator input or when a certain amount of the hard disk is full. Overview of functions • Archiving of messages, process values and reports of the SIMATIC PCS 7 V7.0⋅operator systems • Archiving of batch data from SIMATIC BATCH V7.0 • Cataloging of all data • Swapping out of all data as well as cataloging onto external storage media • Reading-in of the swapped-out data and cataloging from external storage media • Data visualization on the OS clients: - Parameterizing of views (display windows and masks) including the selection criteria for displaying the data - Visualizing of messages in table form dependent on filter functions - Displaying of process values in table or graphic form dependent on filter functions - Visualizing a batch overview (selecting the detailed protocol of a batch from the batch overview is possible) • Exporting of process values in CSV format, e.g. to Microsoft Excel • Access protection with user-specific privileges, also using SIMATIC logon • Configurable redundancy mode ■ Technical specifications Central archive server (CAS) Order No. Central archive server (CAS) Central Archive Server Basic Package V7.0, including 1500 variables Can be expanded by SIMATIC PCS 7 Archives/SIMATIC PCS 7 Archive PowerPacks to up to 120000 variables; 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows Server 2003, single license for 1 installation Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions 6ES7 658-2FA07-0YB0 SIMATIC PCS 7 Archive V7.0 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows XP Professional or Windows Server 2003, single license for 1 installation (Count Relevant License) Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions • 1500 variables 6ES7 658-2EA07-2YB0 • 5000 variables 6ES7 658-2EB07-2YB0 • 10000 variables 6ES7 658-2EC07-2YB0 • 30000 variables 6ES7 658-2ED07-2YB0 • 80000 variables 6ES7 658-2EE07-2YB0 • 120000 variables 6ES7 658-2EF07-2YB0 SIMATIC PCS 7 Archive PowerPack V7.0 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows XP Professional or Windows Server 2003, single license for 1 installation Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions • For expansion from 1500 to 5000 variables 6ES7 658-2EB07-2YD0 • For expansion from 5000 to 10000 variables 6ES7 658-2EC07-2YD0 • For expansion from 10000 to 30000 variables 6ES7 658-2ED07-2YD0 Long-term archiving Up to 11 servers/server pairs simultaneously Approx. 1000/s • For expansion from 30000 to 80000 variables 6ES7 658-2EE07-2YD0 Data input for process-value archiving by one server Approx. 10000/s • For expansion from 80000 to 120000 variables 6ES7 658-2EF07-2YD0 Data input for process-value archiving by all servers Message input by one server (limited by the performance of short-term archiving) Steady-state load approx. 10/s Message peak approx. 3000/4 s 5/24 Additional components for redundant CAS Siemens ST PCS 7 · November 2007 WinCC/Redundancy For alignment of archives following restart; single license for 2 installations Installation required on each of the redundant SIMATIC PCS 7 Industrial Workstations 6AV6 371-1CF06-2AX0 RS 232 connecting cable, 10 m 6ES7 902-1AC00-0AA0 © Siemens AG 2007 Operator system Operation and monitoring via Web SIMATIC PCS 7 Web server ■ Overview ■ Design SIMATIC PCS 7 Web clients Modem INTERNET LAN intranet Web server in a SIMATIC PCS 7 client OS-LAN (terminal bus) Plant bus The SIMATIC PCS 7 Web server can be used to operate and monitor a system via intranet/Internet. The SIMATIC PCS 7 Web server uses the mechanisms of a multi-client for accessing the subordinate OS servers, and makes the project data globally available via intranet/Internet. The project-specific process data in the SIMATIC PCS 7 Web server are accessed via Web clients which are equipped with Internet Explorer. ■ Application A differentiation is basically made between the following types of application when operating and monitoring SIMATIC PCS 7 systems via the Web: • Standard: Up to 50 Web clients access the data of one SIMATIC PCS 7 Web server over intranet/Internet. • Diagnostics: One or only a few Web clients have access to several SIMATIC PCS 7 Web servers/single-user systems for remote operation, diagnostics or monitoring. The products offered in the context of SIMATIC PCS 7 for operation and monitoring via Web permit cost-optimized solutions for both types of task: • Server-based licensing is recommended for the "Standard" type of application. In this case, each SIMATIC PCS 7 Web server requires a SIMATIC PCS 7 Web Server license which includes the simultaneous access of 3, 10, 25 or 50 Web clients. Licenses are not installed on the Web clients themselves. • Diagnostics licenses are tailored for such types of application. The SIMATIC PCS 7 Web Diagnostics license available for the Web diagnostics client allows the latter access to the assigned SIMATIC PCS 7 Web diagnostics servers/single-user systems at all times. On the server side, a SIMATIC PCS 7 Web Diagnostics Server license or SIMATIC PCS 7 Web Server license is required per SIMATIC PCS 7 Web server/ single-user system. Since there are no functional differences between the license-free Web client and the Web client with SIMATIC PCS 7 Web Diagnostics license, mixed operation is possible. The SIMATIC PCS 7 OS server with the Microsoft Windows Server 2003 operating system offered in Chapter "SIMATIC PCS 7 Industrial Workstation" in the Section "System-neutral components" can be used as the basic hardware for the SIMATIC PCS 7 Web server. The OS Software server of the SIMATIC PCS 7 V7.0 process control system is preinstalled on this basic device in addition to the operating system. In order to configure the SIMATIC PCS 7 Web server, you require the license "OS Software Client" in addition to the SIMATIC PCS 7 Web Server license or SIMATIC PCS 7 Web Diagnostics Server license. Deviating from the specification in the ordering data, the license of the OS Software Client in this special application is enabled for the Microsoft Windows Server 2003 operating system. ■ Function The Web clients equipped with Internet Explorer and with plugins installable via the World Wide Web access the project data provided by the SIMATIC PCS 7 Web server via intranet/Internet. The process displays are converted by "Publishing" into a form suitable for presentation by the Internet Explorer. A plant can be operated and monitored via the Web clients in the same manner as via the OS clients. The user must log on with the Web client just as with an OS client, and the rules for assignment of privileges are also identical. The input operations made on the Web clients are recorded in the OS operating log. The integral OS user management guarantees high security when accessing the OS servers from the SIMATIC PCS 7 Web server. In line with the security requirements of the respective system, access protection is possible using password, firewall technology and individual security strategies. Siemens ST PCS 7 · November 2007 5/25 5 © Siemens AG 2007 Operator system Operation and monitoring via Web SIMATIC PCS 7 Web server ■ Selection and Ordering Data Order No. 5 ■ Selection and Ordering Data • For 3 clients 6ES7 658-2GA07-2YB0 • For 10 clients 6ES7 658-2GB07-2YB0 • For 25 clients 6ES7 658-2GC07-2YB0 • For 50 clients 6ES7 658-2GD07-2YB0 SIMATIC PCS 7 PowerPack Web Server V7.0 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows Server 2003, single license for 1 installation Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions For expansion of PCS 7 Web server license • From 3 to up to 10 clients 6ES7 658-2GB07-2YD0 • From 10 to up to 25 clients 6ES7 658-2GC07-2YD0 • From 25 to up to 50 clients 6ES7 658-2GD07-2YD0 SIMATIC PCS 7 OS Software Client V7.0 1) 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows XP Professional, floating license for 1 user Electronic documentation on PCS 7 toolset DVD Type of delivery: • License key disk, emergency key disk, certificate of license, terms and conditions • PCS 7 V7.0 toolset DVDs, Microsoft SQL Server 2005 including EULA and supplementary CDs/DVDs (e.g. Microsoft ServicePacks and tools) 6ES7 658-2CX07-0YA5 SIMATIC PCS 7 Web Diagnostics Client V7.0 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows XP Professional, single license for 1 installation Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions 6ES7 658-2JX07-2YB0 SIMATIC PCS 7 Web Diagnostics Server V7.0 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows Server 2003, single license for 1 installation Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions 6ES7 658-2HX07-2YB0 1) 5/26 Order No. OS Software Client SIMATIC PCS 7 Web Server V7.0 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows Server 2003, single license for 1 installation Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions Siemens ST PCS 7 · November 2007 Deviating from the specification in the ordering data, the license of the OS Software Client V7.0 in this special application is also enabled for the Microsoft Windows Server 2003 operating system. © Siemens AG 2007 Operator systemwwwwww OpenPCS 7 ■ Overview ■ Function OPC clients OS clients OpenPCS 7 server (OS multi-client with OpenPCS 7) Microsoft Visual Basic for Applications Microsoft Excel SAP OS server The OpenPCS 7 interface is based on the OPC specifications (Openness, Productivity, Collaboration) that mainly make use of Microsoft’s DCOM technology (Distributed Component Object Model) for communication between the applications. It supports the following standardized access options: OPC DA (data access server) For read and write access to process values according to OPC specification OPC DA V1.00, V2.05a, V3.00 As an OPC DA server, the OpenPCS 7 server provides other applications with current data from the OS data management. The OPC client can log itself on to ongoing changes or also write values. OPC HDA (historical data access server) Automation systems Systems for production planning, process data evaluation and management (OPC clients) that are at a higher level than the process control system can access SIMATIC PCS 7 V7.0 process data by means of the OpenPCS 7 server. The OpenPCS 7 server collects data for the OPC clients. Depending on the system configuration, these data may be distributed across different SIMATIC PCS 7 stations (OS server, central archive server). The OpenPCS 7 server covers the distribution of data with regard to the period (OS1 / OS2 /… / CAS), the location (OS1 / OS2 / … ) and the redundancy (OS1 master / OS1 standby …). OpenPCS 7 replaces the @PCS 7 previously available in the SIMATIC PCS 7 context, and is simultaneously the pendant to the Connectivity Pack of the WinCC SCADA system. Access to the data of SIMATIC BATCH is therefore impossible. ■ Design The OpenPCS 7 server can be operated in two different configurations: • As autonomous OpenPCS 7 server based on a SIMATIC PCS 7 Industrial Workstation in the client version (recommended preferred configuration), or • as multi-functional SIMATIC PCS 7 Industrial Workstation, client version, with OpenPCS 7 server and OS client functionalities (OpenPCS 7 server/OS client). Each OPC client without PCS 7 OS/WinCC license requires a WinCC/Client Access license for access to the OpenPCS 7 server. The client access license referred to an OpenPCS 7 server is available in two versions: • As access privilege for an OPC client and • as access privilege for any number of OPC clients. For read-only access to archived process values according to OPC Specification OPC HDA V1.20 As an OPC HDA server, the OpenPCS 7 server provides other applications with historical data from the OS archive system. The OPC client, e.g. a reporting tool, can specifically request the required data by defining the start and end of a time interval. Numerous functions, e.g. variance, mean value or integral, already permit preprocessing by the HDA server and thus contribute towards reduction of the communications load. OPC A&E (alarm & events server) For read-only access to messages, alarms and events according to OPC Specification OPC A&E V1.10 As an OPC A&E server, the OpenPCS 7 server passes on OS messages together with all accompanying process values to the subscribers at the production and corporate management levels. They can of course also be acknowledged there. Filter mechanisms and subscriptions ensure that only selected, modified data are transmitted. OPC "H" A&E (historical alarm & events server) For read-only access to archived alarms and messages By means of a Siemens extension to the OPC standard interface, the OpenPCS 7 server is also able to transmit historical alarms and messages from the archive to the subscribers at the production and corporate management levels. OLE-DB Simple, standardized direct access to the archive data in the Microsoft SQL server database of the operator system is possible with the OLE-DB. Through this, all OS archive data are accessible with the accompanying process values, message texts and user texts. Siemens ST PCS 7 · November 2007 5/27 5 © Siemens AG 2007 Operator system Data exchange with host systems OpenPCS 7 ■ Selection and Ordering Data Order No. Multi-functional OpenPCS 7 server/OS client 5 SIMATIC PCS 7 OpenPCS 7/OS Client V7.0 Software for expansion of an existing OS client by OpenPCS 7 server functionality 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows XP Professional, single license for 1 installation Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions 6ES7 658-0GX07-2YB0 Autonomous OpenPCS 7 server SIMATIC PCS 7 OpenPCS 7 V7.0 OpenPCS 7 software for a separate OpenPCS 7 server, based on the hardware of the SIMATIC PCS Workstation, client version 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows XP Professional, single license for 1 installation Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions 5/28 6ES7 658-0HX07-2YB0 Siemens ST PCS 7 · November 2007 ■ Selection and Ordering Data Order No. OPC client access licenses to an OpenPCS 7 server Access privilege for an OPC client WinCC/Client Access License (CAL) Single license for 1 installation 6AV6 371-1ES06-0AX0 Access privilege for any number of OPC clients WinCC/Client Access License (CAL) per processor License for any number of clients per processor 6AV6 371-1ES06-0CX0 © Siemens AG 2007 Batch automation 6/2 6/2 SIMATIC BATCH Introduction 6/3 SIMATIC BATCH hardware 6/5 6/5 6/7 6/8 6/9 6/10 6/11 6/12 6/12 6/12 SIMATIC BATCH software Introduction Server Basic Package Batch Control Center Recipe System Batch Planning Hierarchical Recipe ROP Library Separation Procedures/Formulas SIMATIC BATCH API Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Batch automation SIMATIC BATCH Introduction ■ Design ■ Integration Integration in SIMATIC PCS 7 SIMATIC BATCH is fully integrated in SIMATIC PCS 7. The plant data can be configured entirely using the engineering system. The engineering system transfers all data required for creating recipes to the batch server. It is therefore possible to edit recipes separate from the engineering system. Changes to the configuration which are made on the engineering system are available to the batch server using an update function (online/offline). The SIMATIC Logon integrated in SIMATIC PCS 7 implements the following functions: • Central user administration with access control • Function "Electronic Signature" This means that operations cannot be performed until enabled by authorized Windows users/user groups. 6 Communication with the automation systems SIMATIC BATCH is configured as a single-user system or as a client/server system, and can be used in plants of any size due to its modular architecture and scalability in 5 steps using 10, 20, 40, 100 and unlimited units (instances of plant units). With small applications, e.g. for laboratory automation, SIMATIC BATCH can also be combined with the PC-based starter system SIMATIC PCS 7 BOX 416. The capacity of SIMATIC BATCH is limited to 10 units in this case. However, characteristic for the automation of batch processes using SIMATIC BATCH are client/server architectures with which one batch server and several batch clients process a plant project together. The batch server can also be configured with redundancy in order to increase availability. SIMATIC BATCH communicates with the automation system through the operator system. The PCS 7 operator stations relevant to the batch are made known to the batch server during configuration of the batch applications. Operator instructions and dialogs can also be integrated into the batch-AS communication. Attention is then drawn to necessary operator inputs, or data input is made possible, e.g. for laboratory values. SIMATIC BATCH provides special standard faceplates for controlling and monitoring plant units and equipment modules. SFC instances derived from a SFC-type template are generally used as the interface to the subordinate automation level. The properties of the SFC type can be defined in a features dialog: • Operations • Setpoints/actual values • Instance parameters • Times etc. It is also possible to use special batch interface blocks for communication with the processing programs in the automation systems, e.g. for plant expansions or for connection of non-SIMATIC systems. 6/2 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Batch automation SIMATIC BATCH SIMATIC BATCH hardware ■ Design Redundancy Engineering System SIMATIC BATCH clients and OS clients OS-LAN Batch server OS server Plant bus Automation systems The modularity and flexibility of SIMATIC BATCH are optimally supported by the hardware available. The basic hardware from the Section "SIMATIC PCS 7 Industrial Workstation" in the Chapter "System-neutral components" can be used for SIMATIC BATCH. Please note that the operating system and the ES/OS software of the SIMATIC PCS 7 process control system are preinstalled as standard on the single station, server or client as the basic device. If these basic devices are used for SIMATIC BATCH, it is possible to extend or reject the existing SIMATIC PCS 7 installation, and restore it for the operating system using the restore DVD. Hardware for small plants For small plants, SIMATIC BATCH can be installed together with the OS software on a single station system. You can find further details on the hardware for this OS/BATCH single station with the ordering data of this section: • In the Section "SIMATIC PCS 7 Industrial Workstation" of the Chapter "System-neutral components" • In the Section "OS hardware" in the Chapter "Operator system" A further alternative for small plants is operation of SIMATIC BATCH on the starter system SIMATIC PCS 7 BOX 416. Client/server configuration The batch server redundancy is supported by the SIMATIC BATCH basic package. The two batch servers of a redundant pair of servers have identical configurations. Contrary to the case of OS redundancy, they must always be connected via a separate Ethernet connection in order to optimize the internal communication. Since the batch server is not usually connected to the plant bus, the Ethernet network card of the SIMATIC PCS 7 Industrial Workstation which is provided as standard for the plant bus connection can be used for the redundant communication. An optical or electrical connection can be used depending on the environmental conditions and the distance between the two batch servers, e.g. up to 100 m per crossover network cable (RJ45 connectors). For details, refer to Manual "SIMATIC PCS 7 V7.0 fault-tolerant process control systems"; for appropriate cable material and further accessories, refer to Catalog IK PI. If the SIMATIC BATCH software and the SIMATIC PCS 7 OS software are installed together on a redundant pair of servers, the two servers must be connected together via an additional desktop adapter network card for the redundant communication. The serial RS 232 connection described in the Section "OS redundancy" is omitted. For information and components for connection to a redundant terminal bus, see page 9/28. Expansion options The basic hardware is expandable according to the customer’s particular requirements and whether the hardware is used as single station, server or client with the following options: • Multi-VGA graphics card for connection of up to 4 monitors • Process monitors (see Spage 2/17) The multi-VGA graphics cards "2 Screens" and "4 Screens" are offered for multichannel operation of an OS/batch single station or a batch client with 2 up to 4 process monitors. Using a multiVGA graphics card, the visualization of the plant/unit can be divided among up to 4 process monitors per operator station by using different views. These plant sections can all be operated using just one keyboard and one mouse. The multi-VGA graphics cards are compliant with the EN 55022 and EN 50082 standards. Each card occupies one PCI slot. Note: Since all messages from SIMATIC BATCH are processed in the operator system’s message system, the use of a signal module is only recommendable with multi-function OS/batch stations (clients, single stations). Batch process automation typically has a distributed client/server configuration with one batch server and several batch clients, which together process a plant project. The batch server of such a configuration can also be configured with redundancy in order to increase availability. SIMATIC BATCH clients and OS clients can run on separate or common basic hardware. The batch server software is usually executed on separate server hardware (Batch Server). Depending on the load on the operator system, the OS and batch server software can also be executed on common server hardware (OS/Batch Server). Since the batch server is only a node on the OS-LAN, we recommend that only the server version of the SIMATIC PCS 7 Industrial Workstation with BCE communication is used. The 10/100/1000 Mbit/s Ethernet RJ45 port is already onboard and can be used for connecting to the OS LAN. Siemens ST PCS 7 · November 2007 6/3 6 © Siemens AG 2007 Batch automation SIMATIC BATCH SIMATIC BATCH hardware ■ Selection and Ordering Data 6 ■ Selection and Ordering Data Order No. Order No. Batch single station Additional and expansion components SIMATIC PCS 7 Industrial Workstation, single station version Windows XP Professional MUI operating system (German, English, French, Italian, Spanish, Chinese) See also page 2/15 Desktop adapter network card for redundant communication between two redundant OS/batch servers • SIMATIC PCS 7 ES/OS 547B BCE WXP Connection to plant bus with Ethernet network card RJ45 (PCI) 10/100/1000 Mbit/s and Basic Communication Ethernet (BCE) 6ES7 650-0NF07-0YX0 D) • SIMATIC PCS 7 ES/OS 547B IE WXP Connection to plant bus via Industrial Ethernet with CP 1613 A2 communications processor 6ES7 650-0NF07-0YX1 D) 6ES7 650-0NH07-0YX0 D) - without multi-VGA graphics card 6ES7 650-0NG07-0YX0 D) - with Multi-VGA graphics card "2 Screens" 6ES7 650-0NG07-0YA0 D) - with Multi-VGA graphics card "4 Screens" 6ES7 650-0NG07-0YB0 D) SIMATIC PCS 7 Industrial Workstation, server version Windows Server 2003 MUI operating system (German, English, French, Italian, Spanish, Chinese) Batch client SIMATIC PCS 7 Industrial Workstation, client version Windows XP Professional MUI operating system (German, English, French, Italian, Spanish, Chinese) • SIMATIC PCS 7 OS Client 547B WXP 6/4 B) SIMATIC PCS 7 BOX 416 See page 3/8 B) Subject to export regulations: AL: N, ECCN: EAR99H D) Subject to export regulations: AL: N, ECCN: 5D992B1 Batch server • SIMATIC PCS 7 OS Server 547B BCE SRV03 Connection to plant bus with Ethernet network card RJ45 (PCI) 10/100/1000 Mbit/s and Basic Communication Ethernet (BCE) A5E00504378 Siemens ST PCS 7 · November 2007 Note: Ordering data in abbreviated form; for detailed Ordering data, see page 2/14. © Siemens AG 2007 Batch automation SIMATIC BATCH software Introduction ■ Overview The basic software for all SIMATIC BATCH system configurations (single stations or client/server systems) is the SIMATIC BATCH Server Basic Package, configured with • Batch server software for 10 units (instances of plant units) • 1 x SIMATIC BATCH BatchCC (Batch Control Center) • 1 x SIMATIC BATCH Recipe System (recipe editor) The basic software is always required. It provides everything needed to implement a small SIMATIC BATCH project on the hardware of a SIMATIC PCS 7 BOX 416, a single station or a client/server configuration consisting of a batch client and a batch server. It also includes the SIMATIC Logon for central user administration with access control and for the electronic signature. ■ Design The capacity of the SIMATIC BATCH server basic packages can be expanded by SIMATIC BATCH PO options and PowerPacks. An appropriate number of SIMATIC BATCH BatchCC und SIMATIC BATCH Recipe System option packages is needed to expand the client/server configuration with additional batch clients. The functions of SIMATIC PCS 7 BOX 416, single stations, batch clients and batch servers can be expanded using the following optional packages (see table). 6 SIMATIC BATCH software components for SIMATIC PCS 7 BOX, single station, batch server and batch client Software component SIMATIC PCS 7 BOX 416 Single station Batch server Batch client 1 Batch Server for 10 units n n n Batch Control Center n n n Recipe System n n n SIMATIC BATCH ROP Library opt opt opt SIMATIC BATCH Hierarchical Recipe opt opt opt SIMATIC BATCH Separation Procedures/Formulas opt opt opt opt opt Batch Client 1+n Basic software SIMATIC BATCH server basic package Option packages SIMATIC BATCH API SIMATIC BATCH Batch Planning opt opt opt opt SIMATIC BATCH Batch Control Center opt SIMATIC BATCH Recipe System opt SIMATIC BATCH PO options For expansion of the SIMATIC BATCH Server Basic Package to 20 units opt opt 40 units opt opt 100 units opt opt Unlimited units opt opt n: Components included in delivery of basic software opt: Can be ordered as options SIMATIC BATCH works closely with the operator system and communicates through the operator system with the automation systems. For small plants, SIMATIC BATCH can therefore be installed together with the OS software on a single station or a SIMATIC PCS 7 BOX 416. The ordering data for the OS software can be found in the Chapter "Operator system". Siemens ST PCS 7 · November 2007 6/5 © Siemens AG 2007 Batch automation SIMATIC BATCH software Introduction ■ Function 6 SIMATIC BATCH offers a versatile range of powerful functions for automating batch processes, and these are described in detail in the system documentation. The most important functions of the various program components are presented in summarized form on the following pages. The current system version SIMATIC BATCH V7.0 particularly features the following new functions: • By means of a user-friendly formula editor which is able to link process parameters or constants using the four fundamental arithmetic operations, you can enter formulas at the step points of a sequence (phase parameters, transitions). • Deepening and further development of cooperation with SIMATIC Route Control: - The locations for material transport which are defined in the SIMATIC Manager and are specific to Route Control can be exported to SIMATIC BATCH. - The locations can be used as transfer parameters (source, target or via) for the transport phases so that products of a batch can be routed into other specific units. 6/6 Siemens ST PCS 7 · November 2007 • It is possible to compare text variables and fixed text strings for transitions. • Product names can be saved in the formulas. • System-based support for versioning of recipes, formulas and library objects facilitates plant validation. • Through user-specific saving of individual system settings, e.g. GUI, window or language, the usual working environment is available on any client. • In the recipe editor and in BatchCC (except in the message window), swapping to a new language is effective immediately, i.e. even before the current application is completed. © Siemens AG 2007 Batch automation SIMATIC BATCH software Server Basic Package ■ Overview The SIMATIC BATCH server basic package contains: • Batch server software for 10 units (instances of plant units) • SIMATIC BATCH BatchCC (Batch Control Center) • SIMATIC BATCH Recipe System (recipe editor) An integral component is also SIMATIC Logon for central user administration and access control as well as for the "Electronic signature", e.g. for enabling basic recipes, formulas and library objects. A small SIMATIC BATCH project can be implemented on the hardware of a SIMATIC PCS 7 BOX 416, single station or client/server combination (batch client and batch server) with the SIMATIC BATCH Server Basic Package. The capacity of the Server Basic Package can be extended by means of SIMATIC BATCH PO options and SIMATIC BATCH PowerPacks to batches with 20, 40, 100 or unlimited units. ■ Selection and Ordering Data SIMATIC BATCH Server Basic Package V7.0 (10 units) For single station, client/server configuration or SIMATIC PCS 7 BOX 416, comprising: • Batch server for 10 units 1) • Recipe System • Batch Control Center (BatchCC) 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows XP Professional or Windows Server 2003, single license for 1 installation Type of delivery: License key disk, certificate of license, terms and conditions Order No. 6ES7 657-0SA07-0YB0 C) 6 SIMATIC BATCH PO Option V7.0 For expansion of the SIMATIC BATCH Server Basic Package 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows XP Professional or Windows Server 2003, single license for 1 installation Type of delivery: License key disk, certificate of license, terms and conditions • To 20 units 6ES7 657-0XB07-2YB0 • To 40 units 6ES7 657-0XC07-2YB0 • To 100 units 6ES7 657-0XD07-2YB0 • To unlimited units 6ES7 657-0XE07-2YB0 SIMATIC BATCH PowerPack V7.0 For expansion of the units 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows XP Professional or Windows Server 2003, single license for 1 installation Type of delivery: License key disk, certificate of license, terms and conditions • From 20 units to 40 units 6ES7 657-0XC07-2YD0 • From 40 units to 100 units 6ES7 657-0XD07-2YD0 • From 100 units to unlimited units 6ES7 657-0XE07-2YD0 C) Subject to export regulations: AL: N, ECCN: EAR99S 1) Instances of plant units Siemens ST PCS 7 · November 2007 6/7 © Siemens AG 2007 Batch automation SIMATIC BATCH software Batch Control Center ■ Overview ■ Function 6 The SIMATIC BATCH Batch Control Center (BatchCC) is the "command center" for monitoring and controlling batch processes with SIMATIC BATCH. Using BatchCC you can manage all data relevant to SIMATIC BATCH through a graphical user interface. Note: The SIMATIC BATCH batch control center option package is included once in the SIMATIC BATCH server basic package. 6/8 Siemens ST PCS 7 · November 2007 BatchCC offers powerful functions for the following tasks: • Reading in and updating the plant data of the basic automation • Definition of user privileges for all functions, for clients, or for plant units of SIMATIC BATCH • Definition of material names and codes • Management of master recipes, and starting the recipe editor in order to enter the recipe structure • Management of libraries with recipe elements (library operations) • Importing and exporting of basic recipes, formulas and library objects • Editing of formula categories and management of associated formulas (parameter sets) • Creation of batches with master recipes • Starting of batch processing and controlling of batches • Monitoring and diagnostics of batch processing • Online modification of occupation strategy and assignment of units during batch processing • Recording and archiving of recipes and batch data ■ Selection and Ordering Data SIMATIC BATCH BatchCC V7.0 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows XP Professional or Windows Server 2003, floating license for 1 user Type of delivery: License key disk, certificate of license, terms and conditions Order No. 6ES7 657-0LX07-2YB5 © Siemens AG 2007 Batch automation SIMATIC BATCH software Recipe System ■ Overview ■ Function • Creation of new master recipes and library operations • Modification of existing master recipes and library operations (changes in structure or parameters) • Documentation of master recipes and library operations • Implementation of plausibility checks • Selection of unit candidates using limitation of equipment properties • Assignment of enabling for test or production of master recipes and library operations • Routing of products of one batch into specific other units ■ Selection and Ordering Data The SIMATIC BATCH recipe system option package presents itself to the user in the form of a recipe editor. The recipe editor is a convenient tool for simple, intuitive creation and modification of master recipes and library operations. It has a graphical user interface, editing functions typical of those in Microsoft Windows for single and group objects, and a structural syntax check function. SIMATIC BATCH Recipe System V7.0 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows XP Professional or Windows Server 2003, floating license for 1 user Type of delivery: License key disk, certificate of license, terms and conditions Order No. 6ES7 657-0AX07-2YB5 6 The basis for recipe creation are the batch objects created from the batch plant configuration using the SIMATIC PCS 7 engineering system, e.g. plant units and technological functions. The batch recipe editor can be started individually, but can also be called from BatchCC. Note: The SIMATIC BATCH recipe system option package is included once in the SIMATIC BATCH server basic package. Siemens ST PCS 7 · November 2007 6/9 © Siemens AG 2007 Batch automation SIMATIC BATCH software Batch Planning ■ Overview ■ Function The range of functions includes not only the planning but also the modification, canceling, deleting and releasing of batches. Dividing and saving batches for a production can be performed manually or, after specifying the number of batches and the production quantity, automatically. The following batch parameters can be selected and changed before the release order is given: • Quantity to be prepared • Starting mode (immediately, by operator input or time-controlled) • Plant unit assignment • Formula (parameter set) • Run sequence (interlinking with the previous or next batch) • Indication of batch runtime 6 The SIMATIC BATCH BatchCC enables the creation of individual production orders and batches. Far more planning functionality is offered by the additional SIMATIC BATCH batch planning option package. BatchCC can then be used to plan batches in advance for a large number of production orders. Batch planning and control are conveniently supported and simplified by special displays such as order category list, production order list, batch planning list, batch status list and batch results list. All batches and their plant unit assignments can be clearly presented by a combination of Gantt diagram and table. Conflicts of time or due to multiple assignment of plant units are marked by symbols. Time conflicts are easily eliminated by moving the affected batches in the Gantt diagram. ■ Selection and Ordering Data SIMATIC BATCH Batch Planning V7.0 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows XP Professional or Windows Server 2003, floating license for 1 user Type of delivery: License key disk, certificate of license, terms and conditions 6/10 Siemens ST PCS 7 · November 2007 Order No. 6ES7 657-0BX07-2YB5 © Siemens AG 2007 Batch automation SIMATIC BATCH software Hierarchical Recipe ■ Overview Recipe procedure Plant Partial recipe procedure Unit Recipe operation Technical Equipment Recipe function Individual control unit Unit Plant 6 Individual control unit Technical Equipment Hierarchical recipes according to ISA-88.01 SIMATIC BATCH and SIMATIC PCS 7 form a functional unit that fully covers the models described in the ISA-88.01 standard. ■ Selection and Ordering Data The hierarchical recipe structure is mapped on the plant module as follows: • Recipe procedure for controlling the process or the production in a plant • Partial recipe procedure for controlling a process step in a plant unit • Recipe operation/function for the process engineering task/function in an equipment module SIMATIC BATCH Hierarchical Recipe V7.0 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows XP Professional or Windows Server 2003, single license for 1 installation Type of delivery: License key disk, certificate of license, terms and conditions Order No. 6ES7 657-0FX07-2YB0 Siemens ST PCS 7 · November 2007 6/11 © Siemens AG 2007 Batch automation SIMATIC BATCH software ROP Library ■ Overview ■ Selection and Ordering Data The management of recipe operations is conveniently supported by a user library (ROP library). Library recipe operations can be inserted as a reference in recipe procedures and can thus be modified from a central location. This reduces the requirements for engineering and validation. If the reference link is broken, the recipe operation becomes a fixed component of the recipe procedure, and is thus independent of further central modifications. 6 SIMATIC BATCH ROP Library V7.0 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows XP Professional or Windows Server 2003, single license for 1 installation Type of delivery: License key disk, certificate of license, terms and conditions Order No. 6ES7 657-0GX07-2YB0 Separation Procedures/Formulas ■ Overview ■ Selection and Ordering Data Formula 1 Formula 2 Formula 3 Temperature 1000 kg 90 °C 500 kg 80 °C 900 kg 95 °C Time 10 min 15 min 12 min Salt Pepper Sugar Yes No 100 g Yes No 150 g No Yes 50 g Quantity Master Recipe #1 Master Recipe #2 SIMATIC BATCH Separation Procedures/ Formulas V7.0 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows XP Professional or Windows Server 2003, single license for 1 installation Type of delivery: License key disk, certificate of license, terms and conditions Order No. 6ES7 657-0HX07-2YB0 Master Recipe #3 The flexibility achieved by recipes which are independent of plant units can be increased even further if the procedure and parameter sets (formulas) are separated from one another. Various master recipes can be created by linking several formulas using a recipe procedure. This enables central modification of procedures. The formula structure is determined by the formula category defined by the user. SIMATIC BATCH API ■ Overview ■ Selection and Ordering Data The SIMATIC BATCH API application programming interface is an open interface for custom expansions. It provides the user with access to SIMATIC BATCH data and functions and enables the programming of special industry or project specific applications. 6/12 Siemens ST PCS 7 · November 2007 SIMATIC BATCH API V7.0 1 language (English), executes with Windows XP Professional or Windows Server 2003, single license for 1 installation Type of delivery: License key disk, certificate of license, terms and conditions Order No. 6ES7 657-0MX07-2YB0 © Siemens AG 2007 SIMATIC Route Control 7/2 Introduction 7/4 Route Control hardware 7/6 Route Control runtime software 7/8 Route Control engineering software Siemens ST PCS 7 · November 2007 © Siemens AG 2007 SIMATIC Route Control Introduction ■ Overview ■ Application The possible applications of SIMATIC Route Control extend from small plants with simple/static lines up to plants in the medium and upper performance range with an extensive network of routes/pipes. SIMATIC Route Control is particularly recommended for the following conditions: • Frequent conversions and extensions of the transport network including actuators and sensors • Transport routes with high flexibility, characterized by: - Regularly changing materials - Dynamic selection of the origin and destination of the material transport (including reversal of direction on bidirectional transport routes) • Numerous simultaneous material transports • Plant projects in combination with SIMATIC BATCH 7 SIMATIC Route Control adds a tool for the configuration, control, monitoring and diagnostics of material transports in pipeline networks. It is not specialized on any particular industry. With SIMATIC Route Control, which can also be combined with SIMATIC BATCH, users of SIMATIC PCS 7 are capable of automating not only their production processes and associated warehouses but also the material transports linking both areas. SIMATIC Route Control can handle complex networks as well as simple transport routes. In particular SIMATIC Route Control is predestined for plants with a multitude of complex route combinations or extensive tank farms such as are found above all in the chemical, petrochemical and food and drinks industries. 7/2 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 SIMATIC Route Control Introduction ■ Configuration SIMATIC Route Control is fully integrated in SIMATIC PCS 7 and, thanks to the modular architecture and 3-step scalability (up to 30 / up to 100 / up to 300 simultaneous material transports), can be flexibly adapted to different sizes of plant. SIMATIC Route Control provides graded user privileges for engineering, operating and maintenance personnel who are integrated into the user administration with SIMATIC logon. SIMATIC Logon is an integral component of SIMATIC PCS 7. Route Control in the engineering system The Route Control Engineering Tool, the Route Control Library and the Route Control Assistant are integrated together with the other engineering tools of the SIMATIC PCS 7 process control system in the central engineering system. In SIMATIC PCS 7, blocks from the SIMATIC PCS 7 standard library are inserted into CFC plans and connected to plant control blocks in accordance with the technological requirements in order to control and monitor the elements of a plant. These individual connections are omitted with SIMATIC Route Control (RC). You adapt the standard blocks of the technological elements relevant to RC (RC elements) using standardized interface blocks from the Route Control library, and allow RC to control and monitor the elements during operation. This is of course also possible with existing plantswithout an increased overhead. The blocks of the Route Control library support redundancy at the controller level. They can be used with standard automation systems or also with fault-tolerant systems or mixed configurations. The changes in the engineering system can be recorded (Change log), both in the SIMATIC PCS 7 project and in the RC project. The Route Control Assistant functions as the interface between the PCS 7 basic configuration expanded by RC components and the RC engineering tool. It analyzes the hardware and software configuration of the SIMATIC PCS 7 (multi-)project, and generates a database which serves as the basis for further, RC-specific configuration with the RC engineering tool. During the RC-specific configuration, the elements imported from the SIMATIC PCS 7 project by the Route Control Assistant must be inserted into a sub-route structure. These sub-routes divide the plant. The complete routes will be subsequently "joined together" from them during the automatic route searching. The response of the sub-routes in a particular function are already defined when inserting the elements into them. Functions represent the technological requirements when operating the plant (e.g. "Open source", "Pumps" etc.). Route Control Server/Route Control Center After the transport network has been configured and the variants of the material transports tested, the Route Control configuration data are transferred to the Route Control Server where they can be activated via the Route Control Center at a suitable time from the process engineering viewpoint. From then onwards, the new data are taken into consideration when searching for the route. If a material transport is pending during operation, a route (material transport) is requested by the controller (e.g. using an adapted RC SFC type) or by the operator on the Route Control Center. In addition to definition of the source and target as well as up to 10 optional locations (intermediate points), this also includes the creation of a start signal on the route control block RC_IF_ROUTE in the automation system (AS). The AS "informs" the RC Server which then starts searching for the route and – if possible – combines the statically defined sub-routes into a complete transport route. From this point onward, the Route Control takes over control and monitoring of all RC elements involved in the transport route. If faults occur, detailed diagnostics information is provided concerning the cause, e.g. why the search for a suitable transport route was unsuccessful. The plant control program only switches the individual technological functions, everything else is handled by the Route Control. The Route Control Server (RC Server) supplies the Route Control Clients (Route Control Center) with the necessary data and transfers their operations to the automation systems. For maintenance purposes, an automation system can be specifically set to "in maintenance" (out of service). The material transports being carried out by this automation system are still continued until finished. However, new material transports are no longer permitted. RC block symbols and faceplates In the process displays of the SIMATIC PCS 7 operator systems, each route block is represented by an RC block symbol and an RC faceplate. Through a route block’s RC block symbol it is possible to select its RC faceplate, and through a route block’s RC faceplate it is possible to select the Route Control Center. Drop-down lists for location selection The selection of locations (synonym: nodes) is made simpler in the process display by means of drop-down lists. As a rule: the more finely divided the sub-route structure, the more flexible the subsequent automatic route searching. With purely static routes, a sub-route can already be a complete route. Siemens ST PCS 7 · November 2007 7/3 7 © Siemens AG 2007 SIMATIC Route Control Route Control Hardware ■ Design Engineering System SIMATIC Route Control clients and OS clients OS-LAN The CP 1613 communication integrated in the IE version of the SIMATIC PCS 7 Workstation for single stations and servers is a combination of CP 1613 communications processor and S7-1613 communications software. When using fault-tolerant automation systems, the SIMATIC PCS 7 Workstation requires the S7-REDCONNECT software instead of the S7-1613 communications software. The S7-REDCONNECT Upgrade is suitable for upgrading the communications software (for ordering data, see page 9/28). Redundancy Route Control server OS server Plant bus 7 Automation systems The modularity and flexibility of SIMATIC Route Control are optimally supported by the hardware available. The basic hardware from page 2/14 can be used for SIMATIC Route Control. Hardware for small plants For small plants, SIMATIC Route Control can be installed either alone or together with the OS software on a single station system or a SIMATIC PCS 7 BOX 416. You can select the hardware for the OS/RC single station at page 2/14, page 5/6, or further down in this section. You can find information and the ordering data for the SIMATIC PCS 7 BOX 416 at page 3/8. Client/server configuration Distributed multi-user systems with client/server architecture, expandable with up to 32 clients per server, are typical for the automation of material transports with SIMATIC Route Control. Basically it is possible to operate an RC Server, Batch Server and OS Server on shared basic hardware. However, availability will be higher and performance better if each component has its own server hardware. The availability of the RC Server can be further increased through redundant configuration of the server hardware. SIMATIC PCS 7 supports multiple-station systems with up to 12 servers/server pairs. The Route Control Client is represented by the Route Control Center (RCC). The RCC can be installed on an OS Client, a Batch Client or separate client hardware. RC server and OS/RC single stations can be connected to the Industrial Ethernet plant bus via a CP 1613 A2 communications processor or via a simple FastEthernet network card with BCE (suitable for communication with up to 8 automation systems; not H systems). RC Server redundancy is supported by the SIMATIC Route Control Server software. Further software components or a separate connection between the two servers as is the case with the OS server redundancy or batch server redundancy are not required. With the assistance of the SIMATIC Route Control Server software, the two redundant RC servers carry out mutual monitoring during operation. If the active RC server fails, the redundant partner immediately becomes the master and takes over operation. The RC clients are automatically switched over to the new master in this case. Following return of the failed RC server, data matching is carried out with the active RC server, and the latter remains the master. For information and components for the redundant bus connection (plant bus and terminal bus), see page 9/28. Expansion options The basic hardware (PC basic unit) is expandable with the following options according to the customer’s particular requirements and whether the hardware is used as RC Single Station, RC Server or Batch Client: • Multi-VGA graphics card for connection of up to 4 monitors • Process monitors (see page 2/17) The Multi-VGA graphics cards "2 Screens" and "4 Screens" are offered for multichannel operation of an OS/RC Single Station or a client with 2 up to 4 process monitors. Views distributed over 2 or as many as 4 process monitors by means of a graphics card can be controlled using one keyboard and one mouse. The Multi-VGA graphics cards are compliant with EN 55022 and EN 50082 standards. Each card occupies one PCI slot in the operator station. Note: Since all messages from SIMATIC Route Control are processed in the operator system’s message system, it is not necessary to use a signal module. Requirements for selection of the automation systems SIMATIC Route Control can operate together with the WinAC Slot 416 controller of the SIMATIC PCS 7 BOX 416 (up to 30 simultaneous material transports) and with the following automation systems of the SIMATIC PCS 7 process control system: • AS 416-3 (up to 30 simultaneous material transports) • AS 417-4 • AS 417H Safety-related automation systems, e.g. AS 417F/FH, cannot be used to control material transport with SIMATIC Route Control. 7/4 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 SIMATIC Route Control Route Control Hardware ■ Selection and Ordering Data ■ Selection and Ordering Data Order No. Order No. RC single station Additional and expansion components SIMATIC PCS 7 Industrial Workstation, single station version Windows XP Professional MUI operating system (German, English, French, Italian, Spanish, Chinese) SIMATIC NET S7-REDCONNECT Upgrade for communication with fault-tolerant AS systems, see page 9/28 • SIMATIC PCS 7 ES/OS 547B BCE WXP Connection to plant bus with Ethernet network card RJ45 (PCI) 10/100/1000 Mbit/s and Basic Communication Ethernet (BCE) for up to 8 automation systems (not H-systems) 6ES7 650-0NF07-0YX0 • SIMATIC PCS 7 ES/OS 547B IE WXP Connection to plant bus with CP 1613 A2 communications processor 6ES7 650-0NF07-0YX1 D) Further additional and expansion components can be found at page 2/15 D) Subject to export regulations: AL: N, ECCN: 5D992B1 Note: Ordering data in abbreviated form; for detailed Ordering data, see page 2/14. For Ordering data of the SIMATIC PCS 7 BOX 416, refer to page 3/8. D) RC server 7 SIMATIC PCS 7 Industrial Workstation, server version Windows Server 2003 MUI operating system (German, English, French, Italian, Spanish, Chinese) • SIMATIC PCS 7 OS Server 547B BCE SRV03 Connection to plant bus with Ethernet network card RJ45 (PCI) 10/100/1000 Mbit/s and Basic Communication Ethernet (BCE) for up to 8 automation systems (not H-systems) 6ES7 650-0NH07-0YX0 D) • SIMATIC PCS 7 OS Server 547B IE SRV03 Connection to plant bus with CP 1613 A2 communications processor 6ES7 650-0NH07-0YX1 D) - without multi-VGA graphics card 6ES7 650-0NG07-0YX0 D) - with Multi-VGA graphics card "2 Screens" 6ES7 650-0NG07-0YA0 D) - with Multi-VGA graphics card "4 Screens" 6ES7 650-0NG07-0YB0 D) RC client SIMATIC PCS 7 Industrial Workstation, client version Windows XP Professional MUI operating system (German, English, French, Italian, Spanish, Chinese) • SIMATIC PCS 7 OS Client 547B WXP Siemens ST PCS 7 · November 2007 7/5 © Siemens AG 2007 SIMATIC Route Control Route Control runtime software ■ Overview ■ Function The Route Control Software is structured such that SIMATIC Route Control can be flexibly adapted to different plant sizes and architectures (single/multi-user systems): • Route Control Engineering (component of the SIMATIC PCS 7 Engineering System) • Route Control Server • Route Control Center (RCC) Software components (runtime) SIMATIC Route Control Server Up to 30 simultaneous material transports SIMATIC Single PCS 7 station BOX 416 Server single Server redundant Client 1 1 1 2 -- • From 30 up to 100 simultaneous material transports -- 1 1 2 -- • From 100 up to 300 simultaneous material transports -- 1 1 2 -- SIMATIC Route Control Center 1 1 -- -- 1 Route Control Server The Route Control Server supplies the RC Clients (Route Control Center) with the necessary data and transfers their operations to the automation systems. When a material transport is requested through the Route Control Center, it is the job of the RC Server to dynamically compile a suitable transport route from the partial routes which were configured using a map of the automation systems on the basis of the selected parameters (source, destination and intermediate locations) and with due consideration of other parameters (e.g. function catalogs, function IDs or material IDs). Configuration changes can be taken immediately into account in the determination of a suitable transport route after transfer from the Route Control Engineering Tool to the Route Control Server and subsequent activation through the Route Control Center (online loading). SIMATIC Route Control Server PowerPack 7 SIMATIC Route Control works closely with the operator system, hence where small plants are concerned it is possible for the Route Control Center and Route Control Server to be installed not only on their own but also together with the OS software on a single station or a SIMATIC PCS 7 BOX 416 (up to 30 simultaneous material transports). The ordering data for the OS software can be found in the Chapter "Operator system". In the case of multi-user systems with small quantity frameworks it is also possible to operate the Route Control Server, Batch Server and OS Server on shared basic hardware. However, availability will be higher and performance better if they are installed on separate server hardware. The Route Control Server program package suitable for up to 30 simultaneous material transports can be expanded by means of add-on PowerPacks to meet higher requirements (up to 100 or 300 simultaneous material transports). The Route Control Client is represented by the Route Control Center (RCC). The RCC can be installed on an OS Client, a Batch Client or separate client hardware. 7/6 Siemens ST PCS 7 · November 2007 Route Control Center Route Control Center (RCC) The RCC can be called either from the faceplate of a route block or from the keyset on the operator station. It displays all of a material transport’s relevant route data and error information in several coordinated views © Siemens AG 2007 SIMATIC Route Control Route Control runtime software Key functional features are: • Overview of all RC elements, partial routes and request details • Operation of the selected material transport: Selection of operating mode: manual/automatic; request, start, stop, continue and end material transport in manual mode; set/change request parameters (locations: source, destination, intermediate locations) and general properties (function catalog, function ID, material ID and "ignore error") in manual mode; activate/deactivate sequence functions in manual mode • Diagnostics of material transport request errors caused by locked RC elements, locked partial routes, inconsistent actuations or prohibited sequential material • Diagnostics of currently running material transports: color and text display of transport route status in the route view of the RCC; detailed analyses by evaluation of feedback signals from RC elements • Server functions: select RC Server, display RC Server status, update view (read in data again from the RC Server) • Display of the operator who has logged on • Definition of route parameters (source, destination, material, function ID etc.), and saving and loading these settings with names • Switchover between "AS in maintenance" and "AS in operation" ■ Selection and Ordering Data SIMATIC Route Control Server V7.0 for up to 30 simultaneous material transports For SIMATIC PCS 7 BOX 416, single station and client/server configuration 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows XP Professional or Windows Server 2003, single license for 1 installation Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions Order No. 6ES7 658-7FA07-0YB0 SIMATIC Route Control Server PowerPack V7.0 For expansion of SIMATIC Route Control Server 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows XP Professional or Windows Server 2003, single license for 1 installation Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions 7 • From 30 to up to 100 simultaneous material transports 6ES7 658-7FB07-0YD0 • From 100 to up to 300 simultaneous material transports 6ES7 658-7FC07-0YD0 SIMATIC Route Control Center V7.0 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows XP Professional or Windows Server 2003, floating license for 1 user Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions 6ES7 658-7EX07-0YB5 Siemens ST PCS 7 · November 2007 7/7 © Siemens AG 2007 SIMATIC Route Control Route Control engineering software ■ Overview ■ Function Locations of partial or complete routes are configured in theSIMATIC Manager as "Equipment properties of plant units" and transferred to the RC project together with the other RC-relevant basic data of the SIMATIC PCS 7 project. The configuration requirements caused by many repeated sequences can be minimized by exporting locations in CSV format, duplicating and modifying them using a spreadsheet program, and then importing them again. Locations (synonym: nodes) are parameters for requesting a material transport (source, destination, intermediate locations/via) and which mark the start and end of each partial route, and thus also the source and destination of a material transport. In addition to the basic tools (SIMATIC Manager, CFC, etc.) of the SIMATIC PCS 7 engineering system, the following configuration components of the SIMATIC Route Control Engineering program package are available for configuration of the route control applications: Route Control library 7 The Route Control (RC) configuration supplements the basic SIMATIC PCS 7 plant configuration with blocks from the PCS 7 standard library. Existing plants are then also easy to upgrade with SIMATIC Route Control. Technological elements of relevance for control of the material transport (RC elements) are adapted in the CFC Editor using uniform interface blocks from the Route Control Library. The RC elements include: • Control elements (actuators) • Sensor elements (sensors) • Parameter elements (setpoints) • Connection elements (material information related to partial route) The Route Control library contains blocks for RC and transport route configuration and interface blocks for RC elements. It is provided in the catalog of the CFC editor. Route Control wizard The Route Control wizard is the interface between the SIMATIC PCS 7 basic configuration supplemented with RC interface blocks and the actual RC configuration in the RC engineering tool. The wizard, which can be called up from the SIMATIC Manager menu, accepts the RC-specific configuration data of the SIMATIC PCS 7 project into the Route Control engineering. In doing so, it carries out plausibility checks, defines the AS-OS and AS-AS communication connections (NetPro and CFC), and configures the RC server signals. Route Control Engineering tool Following importing of the basic data of a SIMATIC PCS 7 project relevant to the RC into an RC project, the RC-specific objects are configured using the Route Control Engineering tool: • Partial routes: division of the transport paths into partial routes is used to increase the flexibility and minimize the configuring overhead by means of repeated application. Relevant partial route parameters: "bidirectional" and "priority" (lowest total of partial route priorities is decisive when searching for the overall route). • Interconnections: Through inclusion in a partial route, the RC elements receive additional properties depending on the type, and these can be edited using configuration dialogs (e.g. in the basic setting: "close valve"). • Function catalogs: The partial routes can be assigned to function catalogs depending on technological and product-specific aspects, e.g. "cleaning" or "product transport". In the route search, function catalogs permit restriction of the resulting quantity to the type of material transport. • Function steps/sequence functions: Function catalogs contain as many as 32 configurable technological sequence functions which define the sequence of material transport by means of the RC elements connected in the partial routes, e.g. base position of the control elements, open transport valves, open origin valve, switch on pump). 7/8 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 SIMATIC Route Control Route Control engineering software Configuration of the partial routes and assignment of the RC elements to the partial routes are performed in a matrix of the Route Control Engineering tool. With the aid of generic elements, objects or blocks generated on a user-specific basis can be integrated into the RC project and handled like RC elements. Special configuration functions make it easier to perform repetitive routine work and extend the range of options for controlling material transport, e.g.: • Exporting configuration data in the form of CSV files to Microsoft Excel, copying and editing the data there, and then re-importing the files into Route Control • Controlling the joint use of partial routes by configurable function IDs • Checking material compatibilities and interlocking partial routes in case of incompatible material sequences based on the material ID saved in the connection element of the partial route • Injection of dynamic (external) setpoints coming from the process at runtime into the route block (e.g. weighed quantity) ■ Selection and Ordering Data Order No. SIMATIC Route Control Engineering V7.0 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows XP Professional or Windows Server 2003 Type of delivery: License key disk, emergency key disk (not with rental license), certificate of license, terms and conditions • Floating license for 1 user 6ES7 658-7DX07-0YB5 • Rental license for 30 days 6ES7 658-7DX07-0YB6 7 Siemens ST PCS 7 · November 2007 7/9 © Siemens AG 2007 SIMATIC Route Control 7 7/10 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Asset Management 8/2 Introduction 8/3 Maintenance station Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Asset Management Introduction ■ Overview Automation Maintenance Enterprise Resource Planning (ERP level) Enterprise Asset Management System Manufacturing Execution Systems (MES level) MES Maintenance Operations Controls (Process and field level) Plant Asset Management The PCS 7 Asset Management supplements SIMATIC PCS 7 by a valuable instrument for minimization of the total cost of ownership of a plant. 8 Asset management for plant engineering is understood to be the administration and management of the plant equipment, particularly the I&C equipment, as well as all activities and measures which serve to retain or increase the value of a plant. These primarily include: • Corrective maintenance Reaction to existing fault and diagnostics messages • Preventive maintenance Preventive diagnostics and maintenance • Predictive maintenance Predictive maintenance and diagnostics ■ Function Maintenance functions and information are frequently only available in a separate level independent of the production. Parallel to process control, SIMATIC PCS 7 with the integral asset management system also provides uniform maintenance information and functions in the process control system for the system components of the plant (assets). Supplementary hardware or software tools for asset management functions are therefore superfluous. Whereas the plant operator receives all information relevant to the process via the operator system and can specifically access the process, the maintenance engineer checks the hardware of the automation plant via the maintenance station, and processes its diagnostics messages and maintenance requests. 8/2 Siemens ST PCS 7 · November 2007 When implementing the SIMATIC PCS 7 asset management, consistent attention was paid to the conformity with international standards, specifications and recommendations. SIMATIC PCS 7 asset management takes into account e.g. the NAMUR requirements (process control standards committee in the chemical and pharmaceutical industries) defined in the following documents for systems for asset management at plant level and for status messages from field devices: • NAMUR recommendation NE91 (requirements for systems for asset management at plant level) • NAMUR recommendation NE 105 (requirements for the integration of fieldbus devices in engineering tools) • NAMUR recommendation NE107 (status messages "Device failure", "Maintenance requirements", "Function check" from field devices). In addition, it observes the IEC 61804-2 for describing devices by means of the Electronic Device Description Language (EDDL) and specifications made by the PROFIBUS & PROFINET International (PI) organization, e.g.: • PROFIBUS Profile Guidelines Identification & Maintenance Functions • PROFIBUS PA Profile for Process Control Devices ■ Integration The SIMATIC PCS 7 Asset Management is integrated seamlessly into the SIMATIC PCS 7 process control system as a sector-independent software package. It consistently uses the hardware and software components of the engineering system and operator system. The system interface for maintenance engineers is the maintenance station based on the engineering system (for details, see the next Section "Maintenance station"). ■ Configuration The PCS 7 Asset Management is based on the hardware and software project of the application which is generated during the standard configuration with the SIMATIC PCS 7 engineering system. Supported by the system, all data relevant to the PCS 7 asset management are derived from the project data of the application simply by pressing a button, and the diagnostics displays are also generated. The procedure is simple, and no additional overhead is required for the asset management. It can be summarized as follows: • Generation of the hardware and software project of the application • System-supported generation of the diagnostics displays with all components present in the project, including the display hierarchy, according to the project’s hardware structure. The names of the displays, symbols etc. imported from the project can be changed by users according to personal requirements or depending on project-specific features. These modifications are retained during further operations • Compilation of the configuration data, and downloading to the operator station and maintenance station with subsequent test and commissioning phase. © Siemens AG 2007 Asset Management Maintenance station ■ Overview ■ Design Depending on the architecture of the SIMATIC PCS 7 plant, the maintenance station can be implemented based on a SIMATIC PCS 7 BOX RTX/416, PCS 7 single station or client/server combination. The following table shows possible hardware/software configurations of the maintenance station (MS). Required SIMATIC PCS 7 hardware/software SIMATIC SIMATIC PCS 7 PCS 7 BOX ES RTX/416 single station MS/ES client MS server Basic hardware SIMATIC PCS 7 BOX RTX/416 all-in-one system (Windows XP operating system) The maintenance engineer can process the diagnostics messages and maintenance requests of the assets on the maintenance station. Via the maintenance station the engineer can access: • Components of the process control system, e.g. intelligent field devices and I/O modules, fieldbus, controller, network components and plant bus as well as servers and clients of the operator systems • Assets that do not belong directly to the process control system, such as pumps, motors, centrifuges, heat exchangers or control loops (passive or indirect assets). These are represented by proxy objects in which the diagnostics rules are stored. The maintenance station for PCS 7 asset management uses hardware and software components of the engineering system and operator system. As a result of the close interlacing, ES, OS and asset management functions execute on common hardware. Such a multi-functional station cannot only be used for asset management, but also for system engineering or HMI. The message system, user desktop, display hierarchy and operator prompting are oriented according to the HMI philosophy of the operator system. The diagnostics data of all assets are displayed on uniform faceplates whose contents depend on the intelligence of the respective component. This means that working with the maintenance station is simple and intuitive – complex familiarization is not required. The diagnostics displays structured according to the plant hierarchy with the operating states of all PCS 7 components can be displayed on the maintenance station and also on an OS client. However, enhanced online diagnostics functions in conjunction with HW-Config or SIMATIC PDM can only be called from the maintenance station. n SIMATIC PCS 7 ES/OS 547B BCE/IE WXP (Windows XP operating system) n n SIMATIC PCS 7 OS Server 547B BCE/IE SRV03 (Windows Server 2003 operating system) n Required SIMATIC PCS 7 software corresponding to operating system or basic hardware (without taking into account the quantity frameworks) SIMATIC PCS 7 Engineering Software V7.0 AS/OS SIMATIC PDM PCS 7 V6.0 SP2 HF1 or higher n n n n n SIMATIC PCS 7 OS Software Server V7.0 n SIMATIC PCS 7 OS Software Client V7.0 n SIMATIC PCS 7 Asset Engineering V7.0 n n SIMATIC PCS 7 Asset Runtime V7.0 (basic package and additional asset TAGs) n n n n Two MS servers can also be operated as a redundant pair of servers. The redundant MS servers must be configured like redundant OS servers and expanded by the SIMATIC PCS 7 Asset Runtime software. The SIMATIC PCS 7 Asset Runtime basic package already contains 100 asset TAGs. These can be expanded by cumulative SIMATIC PCS 7 Asset Runtime licenses for 10, 100 or 1000 asset TAGs (Count Relevant Licenses). The user management and access control for the maintenance station accept the SIMATIC Logon integrated in SIMATIC PCS 7. Siemens ST PCS 7 · November 2007 8/3 8 © Siemens AG 2007 Asset Management Maintenance station ■ Function Enhanced information for assets according to IEC 61804-2 Diagnostics message of a component in the faceplate view "Identity" The maintenance station provides comprehensive maintenance information for the system components of the plant (assets). In order to obtain information on the diagnostics status of individual plant areas or components, maintenance engineers can change from the overview display to the respective diagnostics display of the subordinate hardware level. If a fault is signaled in the overview display, the "loop in alarm" function permits rapid switching to the diagnostics faceplate of the associated component. 8 The scope of information available depends on the individual possibilities of the asset, and is filtered according to the user’s area of responsibility. The following information is available: • Display of diagnostics status determined by the system • Information on components such as tag name, vendor or serial number • Display of diagnostics messages of a component • Visualization of type and current state of initiated maintenance measure Information on passive or indirect assets For passive or indirect assets (pumps, motors, control loops etc.) without self-diagnostics, you can use the programmable logic block AssetMon to derive inadmissible operating states from various measured values and their deviations from a defined normal status and to display them as a maintenance alarm on the maintenance station. AssetMon is able to process up to 3 analog values and up to 16 binary values. With the aid of the AssetMon, individual diagnostics structures, project-specific diagnostics rules and condition monitoring functions can also be implemented. 8/4 Siemens ST PCS 7 · November 2007 Further information can be called for assets described by the electronic device description (EDD) according to IEC 61804-2. This information is automatically read out of the components and made available by SIMATIC PDM in the background. • Detailed diagnostics information - Device-specific information from the vendor - Information on fault diagnostics and troubleshooting - Additional documentation • Results of internal condition monitoring functions • Status information (e.g. local operation, local configuration changes) • Display of modification logbook (audit trail) of the component with all entries on the persons, times and types of operator intervention on the component • Parameter view of the assets (display of parameters saved in the component and in the project; if required, also differences between them) Uniform symbols Gut Wartungsbedarf (gering) InstandhaltungsAuftrag unbek./ nicht angefordert Simulation Wartungsanforderung (mittel) InstandhaltungsAuftrag angefordert Konfigurationsänderung erkannt Wartungsalarm (hoch) InstandhaltungsAuftrag in Arbeit Uniform symbols for visualization of the maintenance status and for HMI on the maintenance station A significant feature with visualization of the access management functionality is the uniform symbols and texts for displaying the statuses of all assets, i.e. for operator stations as well as for network components, controllers or field devices. The asset faceplates are also uniform. The amount of information displayed depends on the intelligence of the respective component. © Siemens AG 2007 Asset Management Maintenance station Typical sequence of a maintenance cycle • Intelligent sensors recognize the threat of failures by means of the implemented diagnostics system long before the actual failure, and can signal these. • Diagnostics information on network components and basic PC devices is transferred to the maintenance station via an OPC SNMP link present in the assets. • The symbol of the associated component (e.g. a field device) signals "Maintenance required" on the maintenance station. An entry is automatically made in the message log so that the chronology of occurred events can also be analyzed later. Parallel to this, the vendor’s detailed diagnostics information is determined by means of SIMATIC PDM and the device description (EDD). • On the overview display, maintenance engineers recognize "Maintenance required" in the technological plant. The maintenance engineers are rapidly guided to the corresponding device using standard mechanisms known from the operator station such as "Common display" and "Operator prompting using loop in alarm". Important information is then shown in the faceplate of the associated device, e.g. process tag number, location and device type. • The existing detailed diagnostics information on the problem can then be called using the "Diagnostics" view depending on the device type and vendor, e.g. fault description, cause, trend information or handling instructions. • They can assess the fault in the "Maintenance" view, and initiate corresponding reactions. This can be e.g. the input of a comment or handling instruction, the assignment of a work instruction number, or the increasing/decreasing of the maintenance requirement priority depending on the significance for the technological plant. Current working measures can also be traced/accompanied in this view. All operations can be logged. The log also contains the faceplate contents with ID data, messages, detailed diagnostics information, work instructions, notes and status. • The work request with all information gained on the maintenance station is passed on to the corresponding maintenance department (identified by symbol "Maintenance order requested"). The release for maintenance of the component can also be made on the maintenance station (identified by symbol "Maintenance order being processed"). The current status of the maintenance measure is then indicated for all involved parties, and also for subsequent shifts. • Once the maintenance measure has been carried out, it is concluded on the maintenance station – the status displays then return to the normal state. The complete maintenance cycle is documented on the maintenance station without gaps – automatically and without additional configuration overhead. ■ Selection and Ordering Data SIMATIC PCS 7 Asset Runtime Basic Package V7.0 including SNMP OPC server license and 100 asset TAGs 1) For installation on SIMATIC PCS 7 BOX RTX/416, single station or server 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows XP Professional or Windows Server 2003, single license for 1 installation Type of delivery: License key disk, certificate of license, terms and conditions Order No. 6ES7 658-7GB07-0YB0 SIMATIC PCS 7 Asset Runtime V7.0 for expansion of asset TAGs 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows XP Professional or Windows Server 2003, single license for 1 installation Type of delivery: License key disk, certificate of license, terms and conditions • 10 asset TAGs 6ES7 658-7GA07-2YB0 • 100 asset TAGs 6ES7 658-7GB07-2YB0 • 1000 asset TAGs 6ES7 658-7GC07-2YB0 8 Asset engineering SIMATIC PCS 7 Asset Engineering V7.0 For installation on SIMATIC PCS 7 BOX 416, single station or client 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows XP Professional / Server 2003, floating license for 1 user Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions 1) 6ES7 658-7GX07-0YB5 With asset TAGs, the number of asset objects monitored in SIMATIC PCS 7 is licensed. An asset object represents individual hardware components within a SIMATIC PCS 7 project, e.g. - measuring devices, positioners, switchgear or remote I/O stations monitored per EDD or - basic devices or Ethernet components monitored in the maintenance station via an SNMP OPC link. The asset TAGs of the SIMATIC PCS 7 Asset Runtime licenses (groups of 10, 100 and 1000) are cumulative (Count Relevant Licenses). Siemens ST PCS 7 · November 2007 8/5 © Siemens AG 2007 Asset Management 8 8/6 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Communication 9/2 Introduction 9/3 9/3 9/6 9/28 9/30 Industrial Ethernet Introduction SCALANCE X Industrial Ethernet switches OSM/ESM/OMC Industrial Ethernet switches Passive network components: FastConnect Passive network components: ITP cables and connectors Passive network components: Fiber-optic cables System connection PCS 7 systems Industrial Wireless LAN (IWLAN) 9/33 9/33 9/34 Industrial Security Introduction Industrial Security components 9/35 9/35 PROFIBUS Introduction 9/21 9/23 9/25 9/26 9/36 9/37 9/39 9/40 9/41 9/42 PROFIBUS DP Introduction Electrical networks Optical networks with glass fiber-optic cables Optical networks with plastic fiber-optic cables AS connection Y-Link 9/50 PROFIBUS PA Introduction Routers: DP/PA link and DP/PA coupler Active field distributor AFD and active field splitter AFS FastConnect/SpliTConnect 9/51 9/51 9/52 Other communication AS-Interface Modbus 9/43 9/45 9/49 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Communication Introduction ■ Overview ■ Design Incorporated in Totally Integrated Automation, the unique basis offered by Siemens for uniform automation of all sectors in the production, process or hybrid industries, the SIMATIC NET busses promote fast and reliable communication between the individual systems/applications of the SIMATIC PCS 7 process control systems such as: • Automation systems, distributed I/Os and field components • Asset management/engineering system and operator system • SIMATIC BATCH and SIMATIC Route Control • Process control via Internet/intranet and IT applications. Industrial Ethernet is used as the plant bus as well as OS-LAN (terminal bus) for multi-user systems with client/server architecture. For small systems, the "Basic Communication Ethernet" (BCE) integrated in the SIMATIC PCS 7 Industrial Workstations permits operation of single stations and servers on the plant bus even without a CP 1613 communications processor. In medium and large plants characterized by high requirements, SIMATIC PCS 7 applies modern Gigabit and FastEthernet technology which combines the high security provided by redundant optical rings with the scalable performance provided by switching technology and high transmission rates up to 1 Gbit/s. 9 The SIMATIC NET network components based on globally established standards provide SIMATIC PCS 7 with a powerful and rugged range of products for implementing totally integrated communications networks for reliable data exchange between all system components and levels of a plant. The SIMATIC NET products specially developed for industrial applications are completely suitable for all types of plant in all industrial sectors. They are matched to one another and meet high standards, especially in areas where they are subject to extreme influences, such as • interfering electromagnetic fields, • corrosive liquids and atmospheres, • explosion hazards, • high mechanical loads. The SIMATIC NET products guarantee expandability and safeguard investments through compatible further developments as well as uniformity from incoming goods to outgoing goods and from field devices up to the management information system. 9/2 Siemens ST PCS 7 · November 2007 PROFIBUS in the DP or PA version is used as the communications medium for interfacing intelligent distributed I/O devices, transmitters and actuators to the controller level. The rugged and reliable PROFIBUS is a universal, open fieldbus complying with the IEC 61158 and IEC 61784 international standards. In the PA version (which permits digital data transmission and power supply for the field devices on a two-wire cable), or with a seriesconnected isolating transformer (RS 485-iS coupler), it can be routed intrinsically-safe into hazardous areas of Zone 1. © Siemens AG 2007 Communication Industrial Ethernet Introduction ■ Overview ■ Benefits OS clients Remote client OS-LAN (terminal bus, optical/electrical) SCALANCE X-400 Redundant OS servers SCALANCE X-200/ X-200 IRT SCALANCE W788-1PRO Engineering station Ethernet technology for industrial environment SCALANCE X-400 SCALANCE X-200/X-200 IRT OSM/ ESM Plant bus Industrial Ethernet (optical/electrical) SIMATIC PCS 7 BOX SCALANCE X-400 AS 412H/ AS 414H/ AS 417H Ethernet currently has a market share of over 80% with a tendency to rise further, thus placing it in pole position in the global LAN landscape. Ethernet offers important characteristics that can give you significant advantages for your application: 7 Fast commissioning through simple connections 7 High flexibility since existing networks can be extended without any adverse effects 7 High availability thanks to redundant network topologies 7 Almost unlimited communications performance because scalable performance is available through switching technology if required 7 Networking of different application areas such as office and production areas 7 Investment protection through continuous and compatible further development 7 Plant-wide clock system permits exact assignment of events within the complete plant AS 414/ AS 416/ AS 417 With Industrial Ethernet, SIMATIC NET expands the Ethernet technology by special components and capabilities for use in industrial environments: 7 Network components for tough industrial environments 7 Fast local assembly using the FastConnect cabling system with RJ45 technology 7 Failsafe networks with fast switchover to redundant system (≤ 300 ms) 7 Continuous monitoring of network components through a simple yet effective signaling concept 7 Future-oriented network components with the SCALANCE X Ethernet product family AS 412H/ AS 414H/ AS 417H Industrial Ethernet, connection examples The plant bus and the OS-LAN (terminal bus) for multi-user systems with client/server architecture are implemented with Industrial Ethernet, a powerful area and cell network for industrial applications in line with the international IEEE 802.3 standard (Ethernet). Bus structures with optical rings are particularly suitable for this because of their high noise immunity and high availability. In medium-sized and large plants characterized by high requirements, SIMATIC PCS 7 applies modern Gigabit and FastEthernet technology. This combines the high reliability of optical rings with the scalable performance of switching technology and high transmission rates up to 1 Gbit/s. Siemens ST PCS 7 · November 2007 9/3 9 © Siemens AG 2007 Communication Industrial Ethernet Introduction ■ Design In the various SIMATIC PCS 7 subsystems (ES, OS, AS etc.) onboard interface modules, simple network cards or special communications processors (e.g. CP 1613) are used as communication interfaces. These are defined when selecting the respective system components depending on the requirements (for further information, refer to page 9/28). The communication nodes are integrated into the bus with the aid of Industrial Ethernet switches. The modern Industrial Ethernet switches from the SCALANCE X range are to be recommended in particular. These offer scalable performance at an attractive price and support a wide variety of possible configurations. Further alternatives result by using the tried and tested ESM and OSM switches. Client Client OS LAN (terminal bus) Client-server and server-server communication is carried out on a dedicated Ethernet LAN. The communication network identified as OS LAN or terminal bus can be implemented with standard SIMATIC NET components such as switches, onboard interfaces, network cards, communications processors (CP), cables etc. A ring design avoids communication failures if e.g. the line is damaged or opened at a particular point. To increase the availability even further, the OS LAN can also be distributed redundantly between two rings which are connected together by two pairs of switches (see example configuration). The switches from the SCALANCE X-400, X-300 and X-200 IRT ranges have the standby redundancy function required for this. Each of the redundant servers and clients can then be connected to both rings via two separate interface modules (redundant terminal bus adapter package). Communication is as standard on ring 1. Communication on ring 2 is only activated in the event of a fault on ring 1 which is relevant to the redundant switchover. Industrial Ethernet plant bus OS-LAN (Ethernet), ring 1 OS-LAN (Ethernet), ring 2 9 Redundant servers Redundant Industrial Ethernet plant bus (double ring) AS 412H/ AS 414H/ AS 417H Example configuration with plant bus and OS LAN with two redundant rings 9/4 Siemens ST PCS 7 · November 2007 The automation systems (AS) communicate with one another and with the engineering system and operator systems (servers/single stations) over the Industrial Ethernet plant bus. This can be designed analogous to the OS LAN with standard SIMATIC NET components such as switches, network cards, communications processors (CP), cables etc. In the case of small plants with up to 8 standard automation systems per operator system, single stations and servers can be operated costeffectively on the plant bus using "Basic Communication Ethernet" (BCE) and a FastEthernet network card. The CP 1613 communications processor is always required if more than 8 standard automation systems or fault-tolerant automation systems are used. As far as availability is concerned, ring topologies are always the first choice for the plant bus. With particularly high availability requirements, the plant bus can also be configured as a redundant double ring (two CPs per AS CPU and OS server). Double faults such as a switch failure on ring 1 with a simultaneous interruption in the bus cable on ring 2 can then be tolerated. The two rings in such a configuration are physically separated. The coupling partners are linked together logically when configuring with NetPro over a fault-tolerant S7 connection (4-way redundancy). One switch each takes over the function of the redundancy manager for each ring. The current switches of the SCALANCE X-400, X-300, X-200 IRT and X-200 ranges can be used as the redundancy manager in a ring. Note: Detailed information on Industrial Ethernet and on the network components can be found in Catalog IK PI, in the A&D Mall, or in Catalog CA 01 under "Communication/Networks/SIMATIC NET communication systems". © Siemens AG 2007 Communication Industrial Ethernet Introduction ■ Function SCALANCE X-200 IRT Compact design 7 IP30 protection 7 100-Mbit ports (electrical/optical; number and version depend on device) 7 Max. 4 ports 7 Redundant 24 V DC supply 7 Redundancy manager for the ring 7 Standby redundancy between two rings 7 Variable assembly (DIN rail, SIMATIC rail, horizontal and vertical wall mounting) 7 Electrical ports with collar for FastConnect cabling system 7 Option: C-PLUG swap medium for simple replacement of devices in event of fault 7 Decision aid for Industrial Ethernet switches Different types of switches can be used for the Industrial Ethernet communication within the SIMATIC PCS 7 process control system. In addition to the OSM/ESM switches, these are currently the following switches: SCALANCE X range Switches X-400 SCALANCE X414-3E and X408-2 X-300 SCALANCE X308-2, X308-2LD and X310 X-200 SCALANCE X224, X216, X208, X212-2, X212-2LD, X204-2 and X206-1LD X-200 IRT SCALANCE X204 IRT, X202-2 IRT, X202-2P IRT, X201-3P IRT and X200-4P IRT In order to support you when selecting, the following list shows important properties of the various switch ranges. SCALANCE X-400 7 1-Gbit ports and 100-Mbit ports (optical/electrical, number and version depend on device) 7 Modular design for flexible electrical or optical Industrial Ethernet networks; variable network topology, type and number of ports (retrofitting of optical ports, extension by 8 further ports with X414-3E) 7 Digital inputs 7 Redundant 24 V DC supply 7 Redundancy manager for the ring 7 Standby redundancy (redundant connection between two rings) 7 Many ports at one central position in the control cabinet 7 IP20 protection 7 Electrical 100-Mbit ports with collar for FastConnect cabling system 7 Router functionality (X414-3E; connection of two subnets) 7 Support of office standards such as virtual LANs incl. priority assignment (port-based VLANs), Rapid Spanning Tree (RSTP), Simple Network Management Protocol (SNMP) or IP Multicast filtering (e.g. for video applications) permits integration of automation networks into company networks 7 Configuration of MAC address filters 7 Slot numbering and labeling strips 7 Option: C-PLUG swap medium for simple replacement of devices in event of fault SCALANCE X-300 7 Compact design 7 IP30 protection 7 Gigabit ports and FastEthernet ports (optical/electrical; version depends on device) 7 10 ports (3 x Gigabit and 7 x FastEthernet) 7 Redundant 24 V DC supply 7 Redundancy manager for the ring 7 Standby redundancy between two rings 7 Variable assembly (DIN rail, SIMATIC rail, horizontal and vertical wall mounting) 7 Electrical ports with collar for FastConnect cabling system 7 Option: C-PLUG swap medium for simple replacement of devices in event of fault SCALANCE X-200 7 Compact design 7 IP30 protection 7 100-Mbit ports (electrical/optical; number and version depend on device) 7 6 to 24 ports 7 Redundant 24 V DC supply 7 Redundancy manager for the ring 7 Variable assembly (DIN rail, SIMATIC rail, horizontal and vertical wall mounting) 7 Electrical ports with collar for FastConnect cabling system 7 Operation of SCALANCE X208 in temperature range from -20 to +70 °C 7 Option: C-PLUG swap medium for simple replacement of devices in event of fault OSM/ESM 7 Standby redundancy between two rings 7 Redundancy manager for the ring 7 Digital inputs 7 Configuration of MAC address filtersand had ■ Technical specifications Plant bus / OS-LAN Industrial Ethernet Number of stations 1,023 per network segment (IEEE 802.3 standard) Number of switches Up to 50 Length of the network • Local network Electrical: up to approx. 5 km Optical: up to approx. 150 km • WAN Worldwide with TCP/IP Topology Line, tree, ring, star Siemens ST PCS 7 · November 2007 9/5 9 © Siemens AG 2007 Communication Industrial Ethernet SCALANCE X Industrial Ethernet switches ■ Overview SCALANCE X-300 SCALANCE X-300 switches can be used to implement Industrial Ethernet structures with a line, star or ring topology (non-redundant and redundant rings) with transmission rates up to 1000 Mbit/s. • SCALANCE X310 with 3 electrical Gigabit Ethernet RJ45 ports and 7 electrical FastEthernet RJ45 ports • SCALANCE X308-2 with 2 optical Gigabit Ethernet SC ports for glass multimode FO cables, 1 electrical Gigabit Ethernet RJ45 port and 7 electrical FastEthernet RJ45 ports • SCALANCE X308-2LD with 2 optical Gigabit Ethernet SC ports for glass multimode FO cables, 1 electrical Gigabit Ethernet RJ45 port and 7 electrical FastEthernet RJ45 ports SCALANCE X-200 IRT SCALANCE X-200 IRT switches are used for Industrial Ethernet structures with a line, star or ring topology (non-redundant and redundant rings) with transmission rates up to 100 Mbit/s. • SCALANCE X204 IRT with 4 electrical RJ45 ports • SCALANCE X202-2 IRT with 2 electrical RJ45 ports and 2 optical BFOC ports for glass multimode FO cables • SCALANCE X202-2P IRT with 2 electrical RJ45 ports and 2 POF (polymer optical fiber) ports • SCALANCE X201-3P IRT with 1 electrical RJ45 port and 3 POF ports • SCALANCE X200-4P IRT with 4 POF ports SCALANCE X-200 9 Switches are active network components that specifically distribute data to the relevant addressees. SCALANCE X is the modern range of Industrial Ethernet switches from SIMATIC NET. The SCALANCE X family comprises product lines that complement each other and are carefully tuned to the specific automation task. ■ Application The products referred to below from the SCALANCE X-400, X-300, X-200 IRT and X-200 ranges are suitable for use in SIMATIC PCS 7 systems. SCALANCE X-400 SCALANCE X-400 switches are suitable for designing a plant bus and OS-LAN (terminal bus) with an electrical or optical Gigabit ring technology (non-redundant and redundant rings). • SCALANCE X414-3E with 2 Gigabit Ethernet ports (electrical/optical), 12 electrical FastEthernet ports and optionally 4 optical FastEthernet ports (BFOC); can be expanded by extender module with 8 electrical or 8 optical FastEthernet ports (BFOC) • SCALANCE X408-2 with 4 Gigabit Ethernet ports (electrical/ optical) and 4 FastEthernet ports (electrical/optical) Both versions permit a maximum communications performance, in particular with very large plants with comprehensive quantity frameworks and expansive communication networks. 9/6 Siemens ST PCS 7 · November 2007 SCALANCE X-200 switches are suitable for Industrial Ethernet structures with a line, star or ring topology with transmission rates up to 100 Mbit/s (non-redundant and redundant rings). However, they do not have a standby redundancy functionality (see table with product characteristics). • SCALANCE X208 with 8 electrical RJ45 ports • SCALANCE X204-2 with 2 optical glass FO ports and 4 electrical RJ45 ports • SCALANCE X224 with 24 electrical RJ45 ports • SCALANCE X216 with 16 electrical RJ45 ports • SCALANCE X208 with 8 electrical RJ45 ports • SCALANCE X204-2 with 4 electrical RJ45 ports and 2 optical BFOC ports for glass multimode FO cables • SCALANCE X212-2 with 12 electrical RJ45 ports and 2 optical BFOC ports for glass multimode FO cables • SCALANCE X212-2LD with 12 electrical RJ45 ports and 2 optical BFOC ports for glass singlemode FO cables • SCALANCE X206-1LD with 6 electrical RJ45 ports and 1 optical BFOC port for glass singlemode FO cables © Siemens AG 2007 Communication Industrial Ethernet SCALANCE X Industrial Ethernet switches Operator Station Operator Station Switch SCALANCE X414-3E SIMATIC IT Operator Station Engineering Station SIMATIC BATCH Switch SCALANCE X414-3E 1 Gbit/s terminal bus OS Server (redundant) Switch SCALANCE X414-3E Switch SCALANCE X414-3E 1 Gbit/s plant bus Switch SCALANCE X414-3E Switch SCALANCE X414-3E 9 AS 414H/AS 417H redundant controller PROFIBUS PROFIBUS ET 200M ET 200M Example of the use of SCALANCE X414-3E switches in the SIMATIC PCS 7 process control system Siemens ST PCS 7 · November 2007 9/7 © Siemens AG 2007 Communication Industrial Ethernet SCALANCE X Industrial Ethernet switches ■ Design Product characteristics Features X414-3E X408-2 X310, X308-2, X308-2LD X204 IRT, X202-2 IRT, X202-2P IRT X201-3P IRT, X200-4P IRT X224, X216 X212-2, X212-2LD X208, X206-1LD, X204-2 • • • • • • Compact enclosure LED diagnostics • • • • • • • • SIMATIC world • • • • • • • • 2 x 24 V DC • • • • • • • • Signaling contact • • • • • • • • Local display (set button) • • • • • • • • Diagnostics: Web, SNMP • • • • • • • • PROFINET diagnostics • • • • • • • • C-PLUG • • • • • • • • Ring redundancy with RM • • • • • • • • Standby redundancy • • • • • • • Gigabit technology • • • Modular design • • Digital inputs 8 IT features (VLAN, RSTP, IGMP, ...) • Layer 3 switching (IP routing) • IRT capability • • Summary of interfaces 9 Module type Type and number of ports Gigabit Ethernet 1000 Mbit/s Fast Ethernet 100 Mbit/s Electrical (TP) Optical (FO) Electrical (TP) Optical (FO) RJ45 socket SC socket RJ45 socket Plastic FO: (POF/ Glass FO: PCF) ST socket (BFOC SC RJ socket connection) X414-3E (Gigabit ports either optical or electrical) 2 2 (multimode or singlemode) 12 / 201) – 42) / 123) (multimode or singlemode) X408-2 (Gigabit and FastEthernet ports each either optical or electrical) 4 4 (multimode or singlemode) 4 – 42)(multimode or singlemode) X310 3 – 7 – – X308-2 1 2 (multimode) 7 – – X308-2LD 1 2 (singlemode) 7 – – X204 IRT – – 4 – – X202-2 IRT (optical and electrical ports additive) – – 2 – 2 (multimode) X202-2P IRT (optical and electrical ports additive) – – 2 2 – X201-3P IRT (optical and electrical ports additive) – – 1 3 – X200-4P IRT – – – 4 – X224 – – 24 – – X216 – – 16 – – X212-2 – – 12 – 2 (multimode) X212-2LD – – 12 – 2 (singlemode) X208 – – 8 – – X206-1LD – – 6 – 1 (singlemode) X204-2 (optical and electrical ports additive) – – 4 – 2 (multimode) 1) With additional EM495-8 extender module 2) 2 additive plug-on media modules 3) With EM496-4 extender module and 4 plug-on media modules additive to 2) 9/8 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Communication Industrial Ethernet SCALANCE X Industrial Ethernet switches • Detection of failure of a transmission link or a switch in the ring, and activation of the replacement link within 0.3 s (also in large networks): - With Gigabit Ethernet (SCALANCE X-400 switches in ring) just like - with Fast Ethernet (SCALANCE X-400 switches in ring with SCALANCE X-200, X-200 IRT or OSM/ESM) • Standby functionality for redundant connection of two rings • Slot numbering and labeling strips for unambiguous port identification • Suitable for operating temperatures from 0 to +60 °C SCALANCE X414-3E TP-Ports Fast Ethernet Gigabit Fast Ethernet Slot number 2 3 4 5 6 7 8 9 10 11 MM492-2 MM491-2 MM491-2 2 3 4 5 6 7 8 9 10 11 MM491-2LD EM496-4 extender module 12 13 14 15 SCALANCE X414-3E EM496-4 extender module 9 2 3 4 5 6 7 8 9 10 11 12 13 14 15 MM491-2LD MM491-2 2 3 4 5 6 7 8 9 10 11 e.g. for use in optical gigabit ring, connecting four separate optical nodes and up to twelve electrical nodes MM491-2 MM491-2 MM491-2 SCALANCE X414-3E oder MM491-2 Fast Ethernet MM492-2LD oder Gigabit MM492-2 SCALANCE X414-3E MM491-2LD oder Fast Ethernet MM491-2 EM495-8 extender module 2 3 4 5 6 7 8 9 10 11 12 13 e.g. for use in electrical gigabit ring, connecting ten separate optical nodes and up to twelve electrical nodes SCALANCE X414-3E EM495-8 extender module 2 3 4 5 6 7 8 9 10 11 12 13 e.g. for use in optical gigabit ring with single mode for a distance of up to 10 km, connecting two separate optical nodes and up to twenty electrical nodes G_IK10_XX_10180 MM492-2LD MM491-2 SCALANCE X414-3E and X408-2 • Modular switches with IP20 protection for installation in control cabinets; can be combined with media modules (X414-3E and X408-2) and extenders (only X414-3E) • Mounting possibilities: SIMATIC S7-300 rail or 35 mm DIN rail • Redundant 24 V DC supply • 10/100/1000 Mbit/s technology for different transmission media (8-core electric, twisted-pair or fiber-optic, multimode/ singlemode) • Two (X414-3E) or four (X408-2) integral Gigabit Ethernet twisted-pair interfaces (10/100/1000 Mbit/s, RJ45 sockets) for connecting several switches together • Node connection via 12 (X414-3E) or 4 (X408-2) Fast Ethernet twisted-pair ports integrated in the switch (10/100 Mbit/s; RJ45 sockets with retaining collar) • Extender interface for expansion by 8 Fast Ethernet ports (only X414-3E): - Electrical ports with Fast Ethernet extender (can be docked on right of switch) or - optical ports with module extender and media modules • Implementation of optical Gigabit rings with 2-port Gigabit Ethernet media module for conversion of integral Gigabit Ethernet ports to fiber-optic conductors (FOC): - Module version for multimode (1000BaseSX ports for up to 750 m FOC) and - singlemode (up to 70 km FOC, see Catalog IK PI) • SCALANCE X414-3 has 2 slots for optical Fast Ethernet media modules with 2 ports, SCALANCE X408-2 has 2 universal slots which can be alternatively used for optical Fast Ethernet or Gigabit Ethernet media modules with 2 ports • Integration in optical 100-Mbit/s rings using plug-in 2-port Fast Ethernet media module for multi-mode FOC (up to 3 km) or alternatively single-mode FOC (up to 26 km) • Optical interfacing of remote nodes via a second plug-in 2-port FOC media module for Fast Ethernet • Hot swapping of extenders (only X414-3) and media modules • Max. cable lengths between two modules for communication via multimode FOC (for cables, see page 9/26): - Up to 3000 m via 100BaseFX ports (100 Mbit/s) - Up to 750 m via 1000BaseSX ports (1000 Mbit/s) • Max. cable lengths between two modules for communication via twisted-pair (for cables, see page 9/25): - Up to 100 m via 10/100BaseTX (10/100 Mbit/s) or 1000BaseTX Ports (1000 Mbit/s) SCALANCE X414-3E Possible applications of media and extender modules with SCALANCE X-414-3 Siemens ST PCS 7 · November 2007 9/9 © Siemens AG 2007 Communication Industrial Ethernet SCALANCE X Industrial Ethernet switches e.g. for use in optical gigabit ring with single mode for a distance of up to 10 km, connecting two separate optical nodes and up to four electrical nodes. MM491-2LD or Fast Ethernet MM491-2 MM492-2LD or MM492-2 or 2 3 4 5 6 7 8 MM492-2 Example 2 e.g. for use in optical gigabit ring, connecting up to six electrical nodes or for redundant connection of optical gigabit rings via electrical gigabit segments, connecting up to four electrical nodes. G_IK10_XX_10201 Slot number 2 3 4 5 6 7 8 Gigabit • SCALANCE X308-2 with - 2 optical Gigabit Ethernet SC ports for glass multimode FOC (1000BaseSX) - 1 electrical Gigabit Ethernet RJ45 port (1000BaseTX) - 7 electrical FastEthernet RJ45 ports (10/100BaseTX) • SCALANCE X308-2LD with - 2 optical Gigabit Ethernet SC ports for glass singlemode FOC (1000BaseFX) - 1 electrical Gigabit Ethernet RJ45 port (1000BaseTX) - 7 electrical FastEthernet RJ45 ports (10/100BaseTX) 2 3 4 5 6 7 8 MM492-2LD MM491-2 Example 1 optionally Gigabit or Fast Ethernet SCALANCE X408-2 Possible applications of media modules with SCALANCE X-408-2 SCALANCE X-300 9 With the X310, X308-2 and X308-2LD switches from the SCALANCE X-300 range, it is possible to implement line and star topologies as well as low-cost electrical or optical ring topologies with transmission rates up to 1000 Mbit/s. All switches can be used in the ring as redundancy managers. They additionally support standby redundancy for bus configurations with two redundant rings. As a redundancy manager, an X-300 switch monitors the SCALANCE X switches connected via its ring ports, and switches without interruption to the substitute link on failure of a transmission link or a switch in the ring. Each X-300 switch has 3 Gigabit Ethernet ports and 7 FastEthernet ports which are designed as follows depending on the device type: • SCALANCE X310 with - 3 electrical Gigabit Ethernet RJ45 ports (1000BaseTX) - 7 electrical FastEthernet RJ45 ports (10/100BaseTX) 9/10 Siemens ST PCS 7 · November 2007 Features of the X-300 switches • Rugged metal enclosure of S7-300 format, IP30 protection, for installation in control cabinets • Mounting possibilities: DIN rail, SIMATIC S7-300 rail, direct wall mounting • Redundant 24 V DC supply • Cable length between two devices with electrical transmission per TP ports 1000BaseTX with RJ45 sockets: - Depending on the cable type, up to 90 m with IE FC cable, IE FC RJ45 Modular Outlet and patch cable, up to 10 m with TP-Cord (see page 9/23) • Cable length between two devices with optical transmission: - Up to 750 m via 1000BaseSX ports (1000 Mbit/s) and Industrial Ethernet glass multimode FOC (see page 9/26 or in Catalog IK PI) - Up to 10 km via 1000BaseFX ports (1000 Mbit/s) and Industrial Ethernet glass singlemode FOC (see Section "Passive network components" in Catalog IK PI) • Cable length between two devices with electrical transmission per TP ports 10/100BaseTX with RJ45 sockets: - Depending on the cable type, up to 100 m with IE FC cable and IE FC RJ45 Plugs (see page 9/23 or in Catalog IK PI) - Up to 10 m with TP-Cord (see Section "Passive network components" in Catalog IK PI) • Permissible operating temperature for all device types: 0 to +60°C © Siemens AG 2007 Communication Industrial Ethernet SCALANCE X Industrial Ethernet switches SCALANCE X-200 IRT With the X204 IRT, X202-2 IRT, X202-2P IRT, X201-3P IRT and X200-4P IRT switches from the SCALANCE X-200 IRT range, it is possible to implement line and star topologies as well as lowcost electrical or optical ring topologies with transmission rates up to 100 Mbit/s. All switches can be used in the ring as redundancy managers, and additionally support the standby redundancy for bus configurations with two redundant rings. As a redundancy manager, an X-200 IRT switch monitors the SCALANCE X switches connected via its ring ports, and switches without interruption to the substitute link on failure of a transmission link or a switch in the ring. Each X-200 IRT switch has 4 FastEthernet ports which are designed as follows depending on the device type: • SCALANCE X204 IRT with - 4 electrical RJ45 ports (10/100BaseTX) • SCALANCE X202-2 IRT with - 2 electrical RJ45 ports (10/100BaseTX) - 2 optical BFOC ports (100BaseFX) for glass multimode FOC • SCALANCE X202-2P IRT with - 2 electrical RJ45 ports (10/100BaseTX) - 2 optical POF (Polymer Optical Fiber) ports • SCALANCE X201-3P IRT with - 1 electrical RJ45 port (10/100BaseTX) - 3 optical POF ports • SCALANCE X200-4P IRT with - 4 optical POF ports Features of the X-200 IRT switches • Rugged metal enclosure of S7-300 format, IP30 protection, for installation in control cabinets • Mounting possibilities: DIN rail, SIMATIC S7-300 rail, direct wall mounting • Redundant 24 V DC supply • Cable length between two devices with electrical transmission per TP ports 10/100BaseTX with RJ45 sockets: - Depending on the cable type, up to 100 m with IE FC cable and IE FC RJ45 Plugs (see page 9/23 or in Catalog IK PI) - Up to 10 m with TP-Cord (see Section "Passive network components" in Catalog IK PI) • Cable length of a segment with optical transmission: - Up to 3 km via 100BaseFX ports with BFOC socket (corresponds to ST socket) and Industrial Ethernet glass multimode FOC (see page 9/26 or in Catalog IK PI) - Up to 100 m via POF ports and Industrial Ethernet PCF (Polymer Cladded Fiber) (see Section "Passive network components" in Catalog IK PI) - Up to 50 m via POF ports and Industrial Ethernet POF (Polymer Optical Fiber) (see Section "Passive network components" in Catalog IK PI) • The permissible operating temperatures vary as follows depending on the device type: - -20 to +70°C (X204 IRT) - -10 to +60°C (X202-2-IRT) - 0 to +60°C (X202-2P IRT) - 0 to +50°C (X201-3P IRT) - 0 to +40°C (X200-4P IRT) SCALANCE X-200 9 With the X208, X216, X224, X204-2, X212-2, X212-2LD and X206-1LD switches from the SCALANCE X-200 range, it is possible to implement line and star topologies as well as low-cost electrical or optical ring topologies with transmission rates up to 100 Mbit/s. All switches can be used in the ring as redundancy managers. As a redundancy manager, an X-200 switch monitors the SCALANCE X switches connected via its ring ports, and switches without interruption to the substitute link on failure of a transmission link or a switch in the ring. Siemens ST PCS 7 · November 2007 9/11 © Siemens AG 2007 Communication Industrial Ethernet SCALANCE X Industrial Ethernet switches The SCALANCE X-200 switches have 6 to 24 FastEthernet ports which are designed as follows depending on the device type: • SCALANCE X224 with - 24 electrical RJ45 ports (10/100BaseTX) • SCALANCE X216 with - 16 electrical RJ45 ports (10/100BaseTX) • SCALANCE X208 with - 8 electrical RJ45 ports (10/100BaseTX) • SCALANCE X204-2 with - 4 electrical RJ45 ports (10/100BaseTX) - 2 optical BFOC ports (100BaseFX) for glass multimode FOC • SCALANCE X212-2 with - 12 electrical RJ45 ports (10/100BaseTX) - 2 optical BFOC ports (100BaseFX) for glass multimode FOC • SCALANCE X212-2LD with - 12 electrical RJ45 ports (10/100BaseTX) - 2 optical BFOC ports (100BaseFX) for glass singlemode FOC • SCALANCE X206-1LD with - 6 electrical RJ45 ports (10/100BaseTX) - 1 optical BFOC port (100BaseFX) for glass singlemode FOC Features of the X-200 switches • Rugged metal enclosure of S7-300 format, IP30 protection, for installation in control cabinets • Mounting possibilities: DIN rail, SIMATIC S7-300 rail, direct wall mounting • Redundant 24 V DC supply • Cable length between two devices with electrical transmission per TP ports 10/100BaseTX with RJ45 sockets: - Depending on the cable type, up to 100 m with IE FC cable and IE FC RJ45 Plugs (see page 9/23 or in Catalog IK PI) - Up to 10 m with TP-Cord (see Section "Passive network components" in Catalog IK PI) • Cable length of a segment with optical transmission via 100BaseFX ports with BFOC socket (corresponds to ST socket): - Up to 3 km with Industrial Ethernet glass multimode FOC (see page 9/26 or in Catalog IK PI) - Up to 26 km with Industrial Ethernet glass singlemode FOC (see Section "Passive network components" in Catalog IK PI) • The permissible operating temperatures vary depending on the device type: - -20 to +70°C (X208) - -10 to +60°C (X204-2) - 0 to +60°C (all others) ■ Technical specifications Type SCALANCE X414-3E SCALANCE X408-2 Transmission rate 10/100/1000 Mbit/s 10/100/1000 Mbit/s In the basic device: 2 x RJ45 (10/100/1000 Mbit/s; TP); 12 x RJ45 (10/100 Mbit/s; TP) With extender modules: 8 x RJ45 (10/100 Mbit/s; TP) via EM495-8 4 x RJ45 (10/100/1000 Mbit/s; TP); 4 x RJ45 (10/100 Mbit/s; TP) Interfaces 9 • Communications connection, electrical (see also table "Summary of interfaces") • Communications connection, optical (see also In the basic device: up to 2 x glass FOC with SC sockets table "Summary of interfaces") (1000 Mbit/s) via MM492-2, MM492-2LD, MM492-2LH or MM492-2LH+ media module; or up to 4 x glass FOC with BFOC sockets (100 Mbit/s) via MM491-2 or MM491-2LD media module With extender modules: up to 12 x glass FOC with BFOC sockets (100 Mbit/s) via EM496-4 and MM491-2 or MM491-2LD Up to 4 x glass FOC with SC sockets (1000 Mbit/s) via MM492-2 or MM492-2LD media module; or up to 4 x glass FOC with BFOC sockets (100 Mbit/s) via MM491-2 or MM491-2LD media module • Extender interface EM495-8 or EM496-4 -- • Connection for power supply 1 x 4-contact terminal block 1 x 4-contact terminal block • Connection for signaling contact 1 x 4-contact terminal block 1 x 4-contact terminal block • Connection for digital input signals 2 x 5-contact terminal block -- • Slot for swap medium C-PLUG C-PLUG Power supply 2 x 24 V DC (18 to 32 V) 2 x 24 V DC (18 to 32 V) Current consumption < 2000 mA < 700 mA Power loss at 24 V DC 15 W (without media and extender modules), < 48 W (maximum configuration) 15 W (without media modules), < 48 W (maximum configuration) 9/12 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Communication Industrial Ethernet SCALANCE X Industrial Ethernet switches Type SCALANCE X414-3E SCALANCE X408-2 Network size parameters / TP cable length • 0 to 55 m IE TP Torsion Cable with IE FC RJ45 Plug IE TP Torsion Cable with IE FC RJ45 Plug • 0 to 85 m IE FC Marine/ Trailing/ Flexible/ FRNC Cable with IE FC RJ45 Plug IE FC Marine/ Trailing/ Flexible/ FRNC Cable with IE FC RJ45 Plug • 0 to 100 m IE FC Standard Cable GP with IE FC RJ45 Plug IE FC Standard Cable GP with IE FC RJ45 Plug • 0 to 750 m Cable length multimode FOC at 1000 Mbit/s; MM492-2 with glass FOC 50/125 µm; ≤ 2.7 dB/km with 850 nm; ≥ 600 MHz x km Cable length multimode FOC at 1000 Mbit/s; MM492-2 with glass FOC 50/125 µm; ≤ 2.7 dB/km with 850 nm; ≥ 600 MHz x km • 0 to 3000 m Cable length multimode FOC at 100 Mbit/s; MM491-2 with glass FOC 62.5/125 µm or 50/125 µm; ≤ 1 dB/km with 1300 nm; ≥ 600 MHz x km Cable length multimode FOC at 100 Mbit/s; MM491-2 with glass FOC 62.5/125 µm or 50/125 µm; ≤ 1 dB/km with 1300 nm; ≥ 600 MHz x km • 0 to 10 km Cable length singlemode FOC at 1000 Mbit/s; MM492-2LD with glass FOC 10/125 µm or 9/125 µm; ≤ 0.5 dB/km with 1300 nm Cable length singlemode FOC at 1000 Mbit/s; MM492-2LD with glass FOC 10/125 µm or 9/125 µm; ≤ 0.5 dB/km with 1300 nm • 0 to 26 km Cable length singlemode FOC at 100 Mbit/s; MM491-2LD with glass FOC 10/125 µm or 9/125 µm; ≤ 0.5 dB/km with 1300 nm Cable length singlemode FOC at 100 Mbit/s; MM491-2LD with glass FOC 10/125 µm or 9/125 µm; ≤ 0.5 dB/km with 1300 nm • 0 to 40 km Cable length singlemode FOC at 1000 Mbit/s; MM492-2LH with glass FOC 10/125 µm or 9/125 µm; ≤ 0.5 dB/km with 1300 nm Cable length singlemode FOC at 1000 Mbit/s; MM492-2LH with glass FOC 10/125 µm or 9/125 µm; ≤ 0.5 dB/km with 1300 nm • 0 to 70 km Cable length singlemode FOC at 1000 Mbit/s; MM492-2LH+ with glass FOC 10/125 µm or 9/125 µm; ≤ 0.5 dB/km with 1300 nm Cable length singlemode FOC at 1000 Mbit/s; MM492-2LH+ with glass FOC 10/125 µm or 9/125 µm; ≤ 0.5 dB/km with 1300 nm Permissible ambient conditions • Operating temperature 0 to +60 °C 0 to +60 °C • Transport/storage temperature -40 °C to +80 °C -40 °C to +80 °C • Relative humidity during operation < 95% (no condensation) < 95% (no condensation) Design • Dimensions (W x H x D) in mm 344 x 145 x 117 275 x 145 x 117 • Weight 3.1 kg 1.9 kg • Mounting S7-300 rail, DIN rail S7-300 rail, DIN rail Degree of protection IP20 IP20 Approvals • Radio interference suppression level EN 61000-6-4 Class A EN 61000-6-4 Class A • Noise immunity EN 61000-6-2 EN 61000-6-2 • cUL-Listung UL 60950-1, CSA C22.2 No. 60950-1, UL 508, CSA C22.2 No. 14-M91 UL 1604 and 2279 (Hazardous Location) UL 60950-1, CSA C22.2 No. 60950-1, UL 508, CSA C22.2 No. 14-M91 UL 1604 and 2279 (Hazardous Location) • FM FM 3611, FM Hazardous Location FM 3611, FM Hazardous Location • ATEX Zone 2 EN 50021 EN 50021 • C-Tick AS/NZS 2064 (Class A) AS/NZS 2064 (Class A) • CE EN 61000-6-2, EN 61000-6-4 EN 61000-6-2, EN 61000-6-4 • Shipbuilding approvals • Germanischer Lloyd (GL) • American Bureau of Shipping (ABS) • Llyods Register of Shipping (LRS) • Bureau Veritas (BV) • Nippon Kaiji Kyokai (NK) • Det Norske Veritas (DNV) Available soon Siemens ST PCS 7 · November 2007 9/13 9 © Siemens AG 2007 Communication Industrial Ethernet SCALANCE X Industrial Ethernet switches Type SCALANCE X310 SCALANCE X308-2 SCALANCE X308-2LD Transmission rate 10/100/1000 Mbit/s 10/100/1000 Mbit/s 10/100/1000 Mbit/s 3 x RJ45 (10/100/1000 Mbit/s; TP) 7 x RJ45 (10/100 Mbit/s; TP) 1 x RJ45 (10/100/1000 Mbit/s; TP) 7 x RJ45 (10/100 Mbit/s; TP) 1 x RJ45 (10/100/1000 Mbit/s; TP) 7 x RJ45 (10/100 Mbit/s; TP) Interfaces • Communications connection, electrical (see also table "Summary of interfaces") • Communications connection, optical (see also -table "Summary of interfaces") 2 x glass FO cable (multimode) 2 x glass FO cable (singlewith SC socket (1000 Mbit/s) mode) with SC socket (1000 Mbit/s) • Connection for power supply 1 x 4-contact terminal block 1 x 4-contact terminal block 1 x 4-contact terminal block • Connection for signaling contact 1 x 2-contact terminal block 1 x 2-contact terminal block 1 x 2-contact terminal block • Slot for swap medium C-PLUG C-PLUG C-PLUG Power supply 2 x 24 V DC (18 to 32 V) 2 x 24 V DC (18 to 32 V) 2 x 24 V DC (18 to 32 V) Current consumption 400 mA 400 mA 400 mA Power loss at 24 V DC 9.6 W 9.6 W 9.6 W IE TP Torsion Cable with IE FC RJ45 Plug IE TP Torsion Cable with IE FC RJ45 Plug IE TP Torsion Cable with IE FC RJ45 Plug IE FC Outlet RJ45 with IE TP Torsion Cable (0 to 45 m) + 10 m TP Cord IE FC Outlet RJ45 with IE TP Torsion Cable (0 to 45 m) + 10 m TP Cord IE FC Outlet RJ45 with IE TP Torsion Cable (0 to 45 m) + 10 m TP Cord Network size parameters / TP cable length • 0 to 55 m • 0 to 85 m 9 IE FC Marine/ Trailing/ Flexible/ IE FC Marine/ Trailing/ Flexible/ IE FC Marine/ Trailing/ Flexible/ FRNC Cable with IE FC RJ45 FRNC Cable with IE FC RJ45 FRNC Cable with IE FC RJ45 Plug Plug Plug IE FC Outlet RJ45 with IE FC Marine/Trailing/Flexible Cable (0 to 75 m) + 10 m TP Cord IE FC Outlet RJ45 with IE FC Marine/Trailing/Flexible Cable (0 to 75 m) + 10 m TP Cord IE FC Outlet RJ45 with IE FC Marine/Trailing/Flexible Cable (0 to 75 m) + 10 m TP Cord IE FC Standard Cable GP with IE FC RJ45 Plug IE FC Standard Cable GP with IE FC RJ45 Plug IE FC Standard Cable GP with IE FC RJ45 Plug IE FC Outlet RJ45 with IE FC TP Standard Cable GP (0 to 90 m) + 10 m TP Cord IE FC Outlet RJ45 with IE FC Standard Cable GP (0 to 90 m) + 10 m TP Cord IE FC Outlet RJ45 with IE FC Standard Cable GP (0 to 90 m) + 10 m TP Cord • 0 to 750 m -- Cable length multimode FOC at -1000 Mbit/s; glass FOC 50/125 µm; ≤ 2.7 dB/km with 850 nm; ≥ 600 MHz x km • 0 to 10 km -- -- Cable length singlemode FOC at 1000 Mbit/s; 10/125 µm or 9/125 µm; ≤ 0.5 dB/km with 1300 nm • 0 to 100 m Permissible ambient conditions • Operating temperature 0 to +60 °C 0 to +60 °C 0 to +60 °C • Transport/storage temperature -40 to +80°C -40 to +80 °C -40 to +80 °C • Relative humidity during operation < 95% (no condensation) < 95% (no condensation) < 95% (no condensation) Design • Dimensions (W x H x D) in mm 120 x 125 x 124 120 x 125 x 124 120 x 125 x 124 • Weight 1400 g 1400 g 1400 g • Mounting DIN rail, S7-300 rail, wall mount- DIN rail, S7-300 rail, wall mount- DIN rail, S7-300 rail, wall mounting ing ing Degree of protection IP30 IP30 IP30 Approvals • Radio interference suppression level EN 61000-6-4 Class A EN 61000-6-4 Class A EN 61000-6-4 Class A • Noise immunity EN 61000-6-2 EN 61000-6-2 EN 61000-6-2 • cUL-Listung UL 60950-1, CSA C22.2 No. 60950-1; UL 508, CSA C22.2 No. 14-M91; UL 1604 and 2279 (Hazardous Location) UL 60950-1, CSA C22.2 No. 60950-1; UL 508, CSA C22.2 No. 14-M91; UL 1604 and 2279 (Hazardous Location) UL 60950-1, CSA C22.2 No. 60950-1; UL 508, CSA C22.2 No. 14-M91; UL 1604 and 2279 (Hazardous Location) • FM FM 3611 FM 3611 FM 3611 • ATEX Zone 2 EN 50021 EN 50021 EN 50021 • C-Tick AS/NZS 2064 (Class A) AS/NZS 2064 (Class A) AS/NZS 2064 (Class A) • CE EN 61000-6-2, EN 61000-6-4 EN 61000-6-2, EN 61000-6-4 EN 61000-6-2, EN 61000-6-4 9/14 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Communication Industrial Ethernet SCALANCE X Industrial Ethernet switches Type SCALANCE X204 IRT SCALANCE X202-2 IRT SCALANCE X202-2P IRT Transmission rate 10/100 Mbit/s 10/100 Mbit/s 10/100 Mbit/s 4 x RJ45 (10/100 Mbit/s; TP) 2 x RJ45 (10/100 Mbit/s; TP) 2 x RJ45 (10/100 Mbit/s; TP) 2 x BFOC socket (100 Mbit/s) 2 x SC RJ socket (100 Mbit/s) Interfaces • Communications connection, electrical (see also table "Summary of interfaces") • Communications connection, optical (see also -table "Summary of interfaces") • Connection for power supply 1 x 4-contact terminal block 1 x 4-contact terminal block 1 x 4-contact terminal block • Connection for signaling contact 1 x 2-contact terminal block 1 x 2-contact terminal block 1 x 2-contact terminal block • Slot for swap medium C-PLUG C-PLUG C-PLUG Power supply 2 x 24 V DC (18 to 32 V) 2 x 24 V DC (18 to 32 V) 2 x 24 V DC (18 to 32 V) Current consumption 200 mA 300 mA 300 mA Power loss at 24 V DC 4.8 W 7.2 W 7.2 W • 0 to 50 m -- -- POF 980/1000 with 650 nm 10 MHz x 100 m • 0 to 55 m IE TP Torsion Cable with IE FC RJ45 Plug IE TP Torsion Cable with IE FC RJ45 Plug IE TP Torsion Cable with IE FC RJ45 Plug IE FC Outlet RJ45 with IE TP Torsion Cable (0 to 45 m) + 10 m TP Cord IE FC Outlet RJ45 with IE TP Torsion Cable (0 to 45 m) + 10 m TP Cord IE FC Outlet RJ45 with IE TP Torsion Cable (0 to 45 m) + 10 m TP Cord Network size parameters / TP cable length • 0 to 85 m • 0 to 100 m • 0 to 3000 m IE FC Marine/ Trailing/ Flexible/ IE FC Marine/ Trailing/ Flexible/ IE FC Marine/ Trailing/ Flexible/ FRNC Cable with IE FC RJ45 FRNC Cable with IE FC RJ45 FRNC Cable with IE FC RJ45 Plug Plug Plug IE FC Outlet RJ45 with IE FC Marine/Trailing/Flexible Cable (0 to 75 m) + 10 m TP Cord IE FC Outlet RJ45 with IE FC Marine/Trailing/Flexible Cable (0 to 75 m) + 10 m TP Cord IE FC Outlet RJ45 with IE FC Marine/Trailing/Flexible Cable (0 to 75 m) + 10 m TP Cord -- -- PCF 200/230 with 650 nm 17 MHz x km IE FC Standard Cable GP with IE FC RJ45 Plug IE FC Standard Cable GP with IE FC RJ45 Plug IE FC Standard Cable GP with IE FC RJ45 Plug IE FC Outlet RJ45 with IE FC TP Standard Cable GP (0 to 90 m) + 10 m TP Cord IE FC Outlet RJ45 with IE FC Standard Cable GP (0 to 90 m) + 10 m TP Cord IE FC Outlet RJ45 with IE FC Standard Cable GP (0 to 90 m) + 10 m TP Cord -- Glass FOC 62.5/125 µm or 50/125µm; ≤ 1.0 dB/km with 1300 nm; ≥ 600 MHz x km -- Permissible ambient conditions • Operating temperature -20 °C to +70 °C -10 to +60 °C 0 to +60 °C • Transport/storage temperature -40 °C to +80 °C -40 to +80 °C -40 to +80 °C • Relative humidity during operation < 95% (no condensation) < 95% (no condensation) < 95% (no condensation) Design • Dimensions (W x H x D) in mm 60 x 125 x 124 60 x 125 x 124 60 x 125 x 124 • Weight 780 g 780 g 780 g • Mounting DIN rail, S7-300 rail, wall mounting DIN rail, S7-300 rail, wall mounting DIN rail, S7-300 rail, wall mounting Degree of protection IP30 IP30 IP30 Approvals • Radio interference suppression level EN 61000-6-4 Class A EN 61000-6-4 Class A EN 61000-6-4 Class A • Noise immunity EN 61000-6-2 EN 61000-6-2 EN 61000-6-2 • cUL-Listung UL 60950-1, CSA C22.2 No. 60950-1 UL 60950-1, CSA C22.2 No. 60950-1 UL 60950-1, CSA C22.2 No. 60950-1 • FM FM 3611 FM 3611 FM 3611 • ATEX Zone 2 EN 50021 EN 50021 EN 50021 • C-Tick AS/NZS 2064 (Class A) AS/NZS 2064 (Class A) AS/NZS 2064 (Class A) • CE EN 61000-6-2, EN 61000-6-4 EN 61000-6-2, EN 61000-6-4 EN 61000-6-2, EN 61000-6-4 • Shipbuilding approvals • American Bureau of Shipping • American Bureau of Shipping • Lloyds Register of Shipping • Nippon Kaiji Kyokai • Nippon Kaiji Kyokai • Det Norske Veritas • Det Norske Veritas • Det Norske Veritas • Germanischer Lloyd Siemens ST PCS 7 · November 2007 9/15 9 © Siemens AG 2007 Communication Industrial Ethernet SCALANCE X Industrial Ethernet switches Type SCALANCE X201-3P IRT SCALANCE X200-4P IRT Transmission rate 10/100 Mbit/s 10/100 Mbit/s 1 x RJ45 (10/100 Mbit/s; TP) -- Interfaces • Communications connection, electrical (see also table "Summary of interfaces") • Communications connection, optical (see also 3 x SC RJ socket (100 Mbit/s) table "Summary of interfaces") 4 x SC RJ socket (100 Mbit/s) • Connection for power supply 1 x 4-contact terminal block 1 x 4-contact terminal block • Connection for signaling contact 1 x 2-contact terminal block 1 x 2-contact terminal block • Slot for swap medium C-PLUG C-PLUG Power supply 2 x 24 V DC (18 to 32 V) 2 x 24 V DC (18 to 32 V) Current consumption 350 mA 400 mA Power loss at 24 V DC 8.4 W 9.6 W • 0 to 50 m POF 980/1000 with 650 nm 10 MHz x 100 m POF 980/1000 with 650 nm 10 MHz x 100 m • 0 to 55 m IE TP Torsion Cable with IE FC RJ45 Plug -- IE FC Outlet RJ45 with IE TP Torsion Cable (0 to 45 m) + 10 m TP Cord -- IE FC Marine/ Trailing/ Flexible/ FRNC Cable with IE FC RJ45 Plug -- Network size parameters / TP cable length • 0 to 85 m IE FC Outlet RJ45 with IE FC Marine/Trail-ing/Flexible Cable (0 to 75 m) + 10 m TP Cord • 0 to 100 m 9 • 0 to 3000 m IE FC Standard Cable GP with IE FC RJ45 Plug -- IE FC Outlet RJ45 with IE FC Standard Cable GP (0 to 90 m) + 10 m TP Cord -- PCF 200/230 with 650 nm 17 MHz x km PCF 200/230 with 650 nm 17 MHz x km -- -- Permissible ambient conditions • Operating temperature 0 to +50 °C 0 to +40 °C • Transport/storage temperature -40 to +80 °C -40 to +80 °C • Relative humidity during operation < 95% (no condensation) < 95% (no condensation) Design • Dimensions (W x H x D) in mm 60 x 125 x 124 60 x 125 x 124 • Weight 780 g 780 g • Mounting DIN rail, S7-300 rail, wall mounting DIN rail, S7-300 rail, wall mounting Degree of protection IP30 IP30 Approvals • Radio interference suppression level EN 61000-6-4 Class A EN 61000-6-4 Class A • Noise immunity EN 61000-6-2 EN 61000-6-2 • cUL-Listung UL 60950-1, CSA C22.2 No. 60950-1 UL 60950-1, CSA C22.2 No. 60950-1 • FM FM 3611 FM 3611 • ATEX Zone 2 EN 50021 EN 50021 • C-Tick AS/NZS 2064 (Class A) AS/NZS 2064 (Class A) • CE EN 61000-6-2, EN 61000-6-4 EN 61000-6-2, EN 61000-6-4 • Shipbuilding approvals • Lloyds Register of Shipping • Det Norske Veritas • Germanischer Lloyd • Lloyds Register of Shipping • Det Norske Veritas • Germanischer Lloyd 9/16 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Communication Industrial Ethernet SCALANCE X Industrial Ethernet switches Type SCALANCE X208 SCALANCE X206-1LD SCALANCE X204-2 Transmission rate 10/100 Mbit/s 10/100 Mbit/s 10/100 Mbit/s • Communications connection, electrical (see 8 x RJ45 (10/100 Mbit/s; TP) also table "Summary of interfaces") 6 x RJ45 (10/100 Mbit/s; TP) 4 x RJ45 (10/100 Mbit/s; TP) • Communications connection, optical (see also table "Summary of interfaces") -- 1 x BFOC socket (100 Mbit/s) 2 x BFOC socket (100 Mbit/s) • Connection for power supply 1 x 4-contact terminal block 1 x 4-contact terminal block 1 x 4-contact terminal block • Connection for signaling contact 1 x 2-contact terminal block 1 x 2-contact terminal block 1 x 2-contact terminal block • Slot for swap medium C-PLUG C-PLUG C-PLUG Power supply 2 x 24 V DC (18 to 32 V) 2 x 24 V DC (18 to 32 V) 2 x 24 V DC (18 to 32 V) Current consumption 185 mA 200 mA 215 mA Power loss at 24 V DC 4W 4.8 W 5.16 W IE TP Torsion Cable with IE FC RJ45 Plug IE TP Torsion Cable with IE FC RJ45 Plug IE TP Torsion Cable with IE FC RJ45 Plug IE FC Outlet RJ45 with IE TP Torsion Cable (0 to 45 m) + 10 m TP Cord IE FC Outlet RJ45 with IE TP Torsion Cable (0 to 45 m) + 10 m TP Cord IE FC Outlet RJ45 with IE TP Torsion Cable (0 to 45 m) + 10 m TP Cord Interfaces Network size parameters / TP cable length • 0 to 55 m • 0 to 85 m IE FC Marine/Trailing/ IE FC Marine/Trailing/Flexible/ Flexible/FRNC Cable with IE FC FRNC Cable with IE FC RJ45 RJ45 Plug Plug IE FC Marine/ Trailing/ Flexible/ FRNC Cable with IE FC RJ45 Plug IE FC Outlet RJ45 with IE FC Marine/Trailing/Flexible Cable (0 to 75 m) + 10 m TP Cord IE FC Outlet RJ45 with IE FC Marine/Trailing/Flexible Cable (0 to 75 m) + 10 m TP Cord IE FC Outlet RJ45 with IE FC Marine/Trailing/Flexible Cable (0 to 75 m) + 10 m TP Cord IE FC Standard Cable GP with IE FC RJ45 Plug IE FC Standard Cable GP with IE FC RJ45 Plug IE FC Standard Cable GP with IE FC RJ45 Plug IE FC Outlet RJ45 with IE FC Standard Cable (0 to 90 m) + 10 m TP Cord IE FC Outlet RJ45 with IE FC Standard Cable GP (0 to 90 m) + 10 m TP Cord IE FC Outlet RJ45 with IE FC Standard Cable GP (0 to 90 m) + 10 m TP Cord • 0 to 3 km -- -- Glass FOC 62.5/125 µm or 50/125 µm; ≤ 1.0 dB/km with 1300 nm; ≥ 600 MHz x km • 0 to 26 km -- Glass FOC or 9/125 µm singlemode fiber; 0.5 dB/km with 1300 nm -- • 0 to 100 m Permissible ambient conditions • Operating temperature -20 to +70 °C 0 to +60 °C -10 to +60 °C • Transport/storage temperature -40 to +80 °C -40 to +80 °C -40 to +80 °C • Relative humidity during operation < 95% (no condensation) < 95% (no condensation) < 95% (no condensation) Design • Dimensions (W x H x D) in mm 60 x 125 x 124 60 x 125 x 124 60 x 125 x 124 • Weight 780 g 780 g 780 g • Mounting DIN rail, S7-300 rail, wall mount- DIN rail, S7-300 rail, wall mount- DIN rail, S7-300 rail, wall mounting ing ing Degree of protection IP30 IP30 IP30 Approvals • Radio interference suppression level EN 61000-6-4 Class A EN 61000-6-4 Class A EN 61000-6-4 Class A • Noise immunity EN 61000-6-2 EN 61000-6-2 EN 61000-6-2 • cUL-Listung UL 60950-1, CSA C22.2 No. 60950-1 UL 60950-1, CSA C22.2 No. 60950-1 UL 60950-1, CSA C22.2 No. 60950-1 • FM FM 3611 FM 3611 FM 3611 • ATEX Zone 2 EN 50021 EN 50021 EN 50021 • C-Tick AS/NZS 2064 (Class A) AS/NZS 2064 (Class A) AS/NZS 2064 (Class A) • CE EN 61000-6-2, EN 61000-6-4 EN 61000-6-2, EN 61000-6-4 EN 61000-6-2, EN 61000-6-4 • Shipbuilding approvals • Lloyds Register of Shipping • Det Norske Veritas • Germanischer Lloyd • Nippon Kaiji Kyokai • American Bureau of Shipping • Bureau Veritas • Lloyds Register of Shipping • Det Norske Veritas • Germanischer Lloyd • Nippon Kaiji Kyokai • Bureau Veritas • Lloyds Register of Shipping • Det Norske Veritas • Germanischer Lloyd • Nippon Kaiji Kyokai • Bureau Veritas Siemens ST PCS 7 · November 2007 9/17 9 © Siemens AG 2007 Communication Industrial Ethernet SCALANCE X Industrial Ethernet switches Type SCALANCE X212-2 SCALANCE X212-2LD Transmission rate 10/100 Mbit/s 10/100 Mbit/s 12 x RJ45 (10/100 Mbit/s; TP) 12 x RJ45 (10/100 Mbit/s; TP) • Communications connection, optical (see also 2 x BFOC socket (100 Mbit/s) table "Summary of interfaces") 2 x BFOC socket (100 Mbit/s) Interfaces • Communications connection, electrical (see also table "Summary of interfaces") • Connection for power supply 1 x 4-contact terminal block 1 x 4-contact terminal block • Connection for signaling contact 1 x 2-contact terminal block 1 x 2-contact terminal block • Slot for swap medium C-PLUG C-PLUG Power supply 2 x 24 V DC (18 to 32 V) 2 x 24 V DC (18 to 32 V) Current consumption 330 mA 330 mA Power loss at 24 V DC 7.92 W 7.92 W IE TP Torsion Cable with IE FC RJ45 Plug IE TP Torsion Cable with IE FC RJ45 Plug IE FC Outlet RJ45 with IE TP Torsion Cable (0 to 45 m) + 10 m TP Cord IE FC Outlet RJ45 with IE TP Torsion Cable (0 to 45 m) + 10 m TP Cord IE FC Marine/ Trailing/ Flexible/ FRNC Cable with IE FC RJ45 Plug IE FC Marine/ Trailing/ Flexible/ FRNC Cable with IE FC RJ45 Plug IE FC Outlet RJ45 with IE FC Marine/ Trailing/Flexible Cable (0 to 75 m) + 10 m TP Cord IE FC Outlet RJ45 with IE FC Marine/Trailing/ Flexible Cable (0 to 75 m) + 10 m TP Cord IE FC Standard Cable GP with IE FC RJ45 Plug IE FC Standard Cable GP with IE FC RJ45 Plug IE FC Outlet RJ45 with IE FC Standard Cable GP (0 to 90 m) + 10 m TP Cord IE FC Outlet RJ45 with IE FC Standard Cable GP (0 to 90 m) + 10 m TP Cord • 0 to 750 m Glass FOC 62.5/125 µm or 50/125 µm; ≤ 1.0 dB/km with 1300 nm; ≥ 600 MHz x km -- • 0 to 3 km -- Glass FOC or 9/125 µm singlemode fiber; 0.5 dB/km with 1300 nm • 0 to 26 km IE TP Torsion Cable with IE FC RJ45 Plug IE TP Torsion Cable with IE FC RJ45 Plug Network size parameters / TP cable length • 0 to 55 m • 0 to 85 m • 0 to 100 m 9 Permissible ambient conditions • Operating temperature 0 to +60 °C 0 to +60 °C • Transport/storage temperature -40 to +80 °C -40 to +80 °C • Relative humidity during operation < 95% (no condensation) < 95% (no condensation) Design • Dimensions (W x H x D) in mm 120 x 125 x 124 120 x 125 x 124 • Weight 1200 g 1200 g • Mounting DIN rail, S7-300 rail, wall mounting DIN rail, S7-300 rail, wall mounting Degree of protection IP30 IP30 Approvals • Radio interference suppression level EN 61000-6-4 Class A EN 61000-6-4 Class A • Noise immunity EN 61000-6-2 EN 61000-6-2 • cUL-Listung UL 60950-1, CSA C22.2 No. 60950-1 UL 60950-1, CSA C22.2 No. 60950-1 • FM FM 3611 FM 3611 • ATEX Zone 2 EN 50021 EN 50021 • C-Tick AS/NZS 2064 (Class A) AS/NZS 2064 (Class A) • CE EN 61000-6-2, EN 61000-6-4 EN 61000-6-2, EN 61000-6-4 • Shipbuilding approvals • Lloyds Register of Shipping • Det Norske Veritas • Germanischer Lloyd • Nippon Kaiji Kyokai • Bureau Veritas • Lloyds Register of Shipping • Det Norske Veritas • Germanischer Lloyd • Nippon Kaiji Kyokai • Bureau Veritas 9/18 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Communication Industrial Ethernet SCALANCE X Industrial Ethernet switches Type SCALANCE X216 SCALANCE X224 Transmission rate 10/100 Mbit/s 10/100 Mbit/s 16 x RJ45 (10/100 Mbit/s; TP) 24 x RJ45 (10/100 Mbit/s; TP) Interfaces • Communications connection, electrical (see also table "Summary of interfaces") • Communications connection, optical (see also -table "Summary of interfaces") -- • Connection for power supply 1 x 4-contact terminal block 1 x 4-contact terminal block • Connection for signaling contact 1 x 2-contact terminal block 1 x 2-contact terminal block • Slot for swap medium C-PLUG C-PLUG Power supply 2 x 24 V DC (18 to 32 V) 2 x 24 V DC (18 to 32 V) Current consumption 240 mA 350 mA Power loss at 24 V DC 5.76 W 8.4 W IE TP Torsion Cable with IE FC RJ45 Plug IE TP Torsion Cable with IE FC RJ45 Plug IE FC Outlet RJ45 with IE TP Torsion Cable (0 to 45 m) + 10 m TP Cord IE FC Outlet RJ45 with IE TP Torsion Cable (0 to 45 m) + 10 m TP Cord IE FC Marine/ Trailing/ Flexible/ FRNC Cable with IE FC RJ45 Plug IE FC Marine/ Trailing/ Flexible/ FRNC Cable with IE FC RJ45 Plug IE FC Outlet RJ45 with IE FC Marine/Trailing/ Flexible Cable (0 to 75 m) + 10 m TP Cord IE FC Outlet RJ45 with IE FC Marine/Trailing/ Flexible Cable (0 to 75 m) + 10 m TP Cord IE FC Standard Cable GP with IE FC RJ45 Plug IE FC Standard Cable GP with IE FC RJ45 Plug IE FC Outlet RJ45 with IE FC Standard Cable GP (0 to 90 m) + 10 m TP Cord IE FC Outlet RJ45 with IE FC Standard Cable GP (0 to 90 m) + 10 m TP Cord • Operating temperature 0 to +60 °C 0 to +60 °C • Transport/storage temperature -40 to +80 °C -40 to +80 °C • Relative humidity during operation < 95% (no condensation) < 95% (no condensation) Network size parameters / TP cable length • 0 to 55 m • 0 to 85 m • 0 to 100 m 9 Permissible ambient conditions Design • Dimensions (W x H x D) in mm 120 x 125 x 124 120 x 125 x 124 • Weight 1200 g 1200 g • Mounting DIN rail, S7-300 rail, wall mounting DIN rail, S7-300 rail, wall mounting Degree of protection IP30 IP30 • Radio interference suppression level EN 61000-6-4 Class A EN 61000-6-4 Class A • Noise immunity EN 61000-6-2 EN 61000-6-2 • cUL-Listung UL 60950-1, CSA C22.2 No. 60950-1 UL 60950-1, CSA C22.2 No. 60950-1 • FM FM 3611 FM 3611 • ATEX Zone 2 EN 50021 EN 50021 • C-Tick AS/NZS 2064 (Class A) AS/NZS 2064 (Class A) • CE EN 61000-6-2, EN 61000-6-4 EN 61000-6-2, EN 61000-6-4 • Shipbuilding approvals • Lloyds Register of Shipping • Det Norske Veritas • Germanischer Lloyd • Nippon Kaiji Kyokai • American Bureau of Shipping • Bureau Veritas • Lloyds Register of Shipping • Det Norske Veritas • Germanischer Lloyd • Nippon Kaiji Kyokai • American Bureau of Shipping • Bureau Veritas Approvals Siemens ST PCS 7 · November 2007 9/19 © Siemens AG 2007 Communication Industrial Ethernet SCALANCE X Industrial Ethernet switches ■ Selection and Ordering Data ■ Selection and Ordering Data Order No. Industrial Ethernet switches, transmission rate 10/100/1000 Mbit/s for electrical and/or optical Industrial Ethernet networks, especially for Fast Ethernet and Gigabit rings SCALANCE X-400 Industrial Ethernet switches • SCALANCE X414-3E 2 x 10/100/1000 Mbit/s and 12 x 10/100 Mbit/s RJ45 ports; 1 x Gigabit Ethernet and 2 x Fast Ethernet media module slots; 1 x Extender interface 6GK5 414-3FC00-2AA2 • SCALANCE X408-2 4 x 10/100/1000 Mbit/s and 4 x 10/100 Mbit/s RJ45 ports; 2 x Gigabit/Fast Ethernet media module slots 6GK5 408-2FD00-2AA2 MM491/MM492 media modules Media modules with 2 ports; 1 Gbit/s, SC connection 9 • MM492-2 media module 1000BaseSX, multi-mode FO cable up to 750 m 6GK5 492-2AL00-8AA2 B) • MM492-2LD media module 1000BaseLX, single-mode FO cable up to 10 km 6GK5 492-2AM00-8AA2 E) • MM492-2LH media module 1000BaseLX, single-mode FO cable up to 40 km 6GK5 492-2AN00-8AA2 • MM492-2LH+ media module 1000BaseLX, single-mode FO cable up to 70 km 6GK5 492-2AP00-8AA2 Order No. SCALANCE X-200 IRT Industrial Ethernet switches • SCALANCE X204 IRT 4 x 10/100 Mbit/s RJ45 ports 6GK5 204-0BA00-2BA3 • SCALANCE X202-2 IRT 2 x 10/100 Mbit/s RJ45 ports, 2 x 100 Mbit/s multi-mode BFOC ports (100BaseFX) 6GK5 202-2BB00-2BA3 • SCALANCE X202-2P IRT 2 x 10/100 Mbit/s RJ45 ports, 2 x 100 Mbit/s POF/PCF SC RJ ports 6GK5 202-2BH00-2BA3 • SCALANCE X201-3P IRT 1 x 10/100 Mbit/s RJ45 port, 3 x 100 Mbit/s POF/PCF SC RJ ports 6GK5 201-3BH00-2BA3 • SCALANCE X200-4P IRT 4 x 100 Mbit/s POF/PCF SC RJ 6GK5 200-4AH00-2BA3 SCALANCE X-200 Industrial Ethernet switches with electrical ports and optical ports for glass multimode FO cable up to 3 km • SCALANCE X204-2 4 x 10/100 Mbit/s RJ45 ports 2 x 100 Mbit/s multi-mode BFOC ports (100BaseFX) 6GK5 204-2BB10-2AA3 • SCALANCE X212-2 12 x 10/100 Mbit/s RJ45 ports 2 x 100 Mbit/s multi-mode BFOC ports (100BaseFX) 6GK5 212-2BB00-2AA3 SCALANCE X-200 Industrial Ethernet switches with electrical ports and optical ports for glass singlemode FO cable up to 26 km Media modules with 2 ports; 100 Mbit/s, BFOC connection (ST sockets) • MM491-2 media module 100BaseFX, multi-mode FO cable up to 3 km 6GK5 491-2AB00-8AA2 • MM491-2LD media module 100BaseFX long distance, single-mode FO cable up to 26 km 6GK5 491-2AC00-8AA2 EM495/EM496 extender modules for SCALANCE X414-3E • EM495-8 extender module with 8 x 10/100 Mbit/s TP ports 6GK5 495-8BA00-8AA2 • EM496-4 extender module with 4 slots for 100 Mbit/s media modules 6GK5 496-4MA00-8AA2 • SCALANCE X206-1LD 6 x 10/100 Mbit/s RJ45 ports 1 x 100 Mbit/s singlemode BFOC ports (100BaseFX) 6GK5 206-1BC10-2AA3 • SCALANCE X212-2LD 12 x 10/100 Mbit/s RJ45 ports 2 x 100 Mbit/s singlemode BFOC ports (100BaseFX) 6GK5 212-2BC00-2AA3 SCALANCE X-200 Industrial Ethernet switches with electrical ports • SCALANCE X208 8 x 10/100 Mbit/s RJ45 ports 6GK5 208-0BA10-2AA3 Industrial Ethernet switches, transmission rate 10/100 Mbit/s for Industrial Ethernet line, star or ring topologies • SCALANCE X216 16 x 10/100 Mbit/s RJ45 ports 6GK5 216-0BA00-2AA3 SCALANCE X-300 Industrial Ethernet switches • SCALANCE X224 24 x 10/100 Mbit/s RJ45 ports 6GK5 224-0BA00-2AA3 • SCALANCE X310 3 x 10/100/1000 Mbit/s RJ45 ports 7 x 10/100 Mbit/s RJ45 ports 6GK5 310-0FA00-2AA3 Accessory for Industrial Ethernet switches • SCALANCE X308-2 2 x 1000 Mbit/s multimode SC ports (1000BaseSX) 1 x 10/100/1000 Mbit/s RJ45 port 7 x 10/100 Mbit/s RJ45 ports 6GK5 308-2FL00-2AA3 C-PLUG Swap medium for simple replacement of devices in event of fault; for saving of configuration and application data, can be used in SIMATIC NET products with C-PLUG slot • SCALANCE X308-2LD 2 x 1000 Mbit/s singlemode SC ports (1000BaseFX) 1 x 10/100/1000 Mbit/s RJ45 port 7 x 10/100 Mbit/s RJ45 ports 6GK5 308-2FM00-2AA3 9/20 6GK1 900-0AB00 E) B) B) Subject to export regulations: AL: N, ECCN: EAR99H E) Subject to export regulations: AL: N, ECCN: 5A991 Siemens ST PCS 7 · November 2007 Note: For further components and accessories, especially cable material and connectors as well as tools and supplementary material for assembly, refer to page 9/23, 9/25 and 9/26 as well as to Catalog IK PI. © Siemens AG 2007 Communication Industrial Ethernet OSM/ESM/OMC Industrial Ethernet switches ■ Overview The transmission rate in the ring is 100 Mbit/s; for each ring, up to 50 Industrial Ethernet OSMs (optical ring) or ESMs (electrical ring) can be used. Apart from the 2 ring ports, OSM/ESM has other ports (with either RJ45, ITP or BFOC interfaces) to which data terminals or network segments can be connected. Selection support for the various product versions of OSM is provided by the table under "Technical specifications". Industrial Ethernet media converter Industrial Ethernet nodes with RJ45 TP interface can be connected via an Industrial Ethernet media converter to one of the 8 optical ports of an OSM BC08. The two types of media converter SCALANCE X101-1 or X101-1LD convert the electric twisted-pair interface, port type 10/100BaseTX (10/100 Mbit/s, RJ45 socket) as follows: • X101-1: into an optical interface for multimode glass FOC • X101-1LD: into an optical interface for singlemode glass FOC The port type of the optical interface is 100BaseFX in each case (100 Mbit/s; 2 x BFOC socket). Notes: Just like the OMC TP11 media converter, the SCALANCE X101-1 does not support diagnostics per SNMP protocol. For further information on the Industrial Ethernet media converter, see Catalog IK PI, Section "Active network components - Industrial Ethernet media converter". Industrial Ethernet OSM and ESM The Industrial Ethernet OSM (Optical Switch Module) and ESM (Electrical Switch Module) are used in the construction of switched networks with data transmission rates of 100 Mbit/s in the control level range, in which strict demands are placed on network availability and comprehensive diagnostics are required. In existing networks, load decoupling and thus increased network performance can be achieved by creating segments (dividing a network into subnetworks/segments) and connecting these segments to an OSM/ESM. The redundancy manager integrated into OSM/ESM allows Industrial Ethernet rings to be constructed in switching technology with high-speed switching over of the communication path on failure of a switch or interruption in the transmission path (reconfiguration time max. 0.3 seconds). Selection support for product versions of OSM and ESM Single-mode FO Preferentially for use Multi-mode FO Type and number of ports Sub-D (ITP) ■ Application ■ Technical specifications RJ45 (TP) The Industrial Ethernet OSM and ESM switches are used to construct Industrial Ethernet networks at the control level: • The modules are interconnected (backbone) at 100 Mbit/s over - Glass fiber-optic cables (FO) for OSM - Twisted pair cables for ESM • Connection of data terminals or network segments depending on the OSM/ESM type through - 2 to 8 twisted pair ports 10/100BaseTX in RJ45 or 9-pole Sub-D design for 10/100 Mbit/s - 3 or 8 FO ports 100BaseFX with BFOC interface (ST socket) for 100 Mbit/s • Integral redundancy manager supports high-speed media redundancy also for large networks • Very easy network configuration and extension without complex configuration rules or parameterization With high EMC loading OSM TP22 2 – 2 – n 1) n n OSM ITP62 (Standard) – 6 2 – n n n OSM TP62 6 – 2 – n n OSM ITP62-LD – 6 – 2 n n n For plant bus For terminal bus (OSLAN) 2) n 2) OSM ITP53 – 5 3 – n OSM BC08 – –- 8 – n 3) n 3) n 3) 4) 4) n 4) n SCALANCE X101-1 1 –- 1 – n SCALANCE X101-1LD 1 –- –- 1 n 4) n 4) n 4) ESM ITP80 – 8 – – n n 5) n ESM TP40 4 – – – n 6) n – n 6) n ESM TP80 8 – – n 1) TP cable preferably inside a control cabinet 2) For cross-building connection of Fast Ethernet networks with OSM 3) For design of an optical network, where TP cables are preferably only used inside control cabinets 4) Connects a station with RJ45-TP interface to one of the 8 optical ports of an OSM BC08 5) Inside buildings 6) Inside switchrooms Siemens ST PCS 7 · November 2007 9/21 9 © Siemens AG 2007 Communication Industrial Ethernet OSM/ESM/OMC Industrial Ethernet switches ■ Selection and Ordering Data 9 Order No. ■ Selection and Ordering Data Order No. Industrial Ethernet OSM TP22 Optical switch module with 2 fiber optic ports 100 Mbit/s, 2 RJ45 ports 10/100 Mbit/s and 4 digital inputs; redundant 24 V DC supply and signal contact; with network management 6GK1 105-2AE00 Industrial Ethernet ESM TP40 Electrical switch module with 4 RJ45 ports 10/100 Mbit/s and 4 digital inputs; redundant 24 V DC supply and signal contact; with network management, preferably for OS-LAN 6GK1 105-3AC00 Industrial Ethernet OSM ITP62 Optical switch module with 2 fiber optic ports 100 Mbit/s, 6 ITP ports 10/100 Mbit/s and 8 digital inputs; redundant 24 V DC supply and signal contact; with network management 6GK1 105-2AA10 Industrial Ethernet ESM ITP80 Electrical switch module with 8 ITP ports 10/100 Mbit/s and 8 digital inputs; redundant 24 V DC supply and signal contact; with network management, preferably for OS-LAN 6GK1 105-3AA10 Industrial Ethernet OSM TP62 Optical switch module with 2 fiber optic ports 100 Mbit/s, 6 RJ45 ports 10/100 Mbit/s and 8 digital inputs; redundant 24 V DC supply and signal contact; with network management 6GK1 105-2AB10 Industrial Ethernet ESM TP80 Electrical switch module with 8 RJ45 ports 10/100 Mbit/s and 8 digital inputs; redundant 24 V DC supply and signal contact; with network management, preferably for OS-LAN 6GK1 105-3AB10 Industrial Ethernet OSM ITP62-LD Optical switch module with 2 fiber optic ports 100 Mbit/s long distance (single-mode fiber optic cable up to 26 km), 6 ITP ports 10/100 Mbit/s and 8 digital inputs; redundant 24 V DC supply and signal contact; with network management 6GK1 105-2AC10 Industrial Ethernet OSM BC08 Optical switch module with 8 fiber optic ports 100 Mbit/s and 8 digital inputs; redundant 24 V DC supply and signal contact; with network management 6GK1 105-4AA00 6GK5 101-1BB00-2AA3 E) Industrial Ethernet OSM ITP53 Optical switch module with 3 fiber optic ports 100 Mbit/s, 5 ITP ports 10/100 Mbit/s and 8 digital inputs; redundant 24 V DC supply and signal contact; with network management, for cross-building connection of two Fast Ethernet networks with OSM 6GK1 105-2AD10 SCALANCE X101-1 Industrial Ethernet media converter For conversion from RJ45 TP to multimode fiber optic cable (BFOC) with 100 Mbit/s; 1 x 10/100 Mbit/s RJ45 Port and 1 x 100 Mbit/s multimode BFOC; redundant 24 V supply and signal contact SCALANCE X101-1LD Industrial Ethernet media converter For conversion from RJ45 TP to singlemode fiber optic cable (BFOC) with 100 Mbit/s; 1 x 10/100 Mbit/s RJ45 Port and 1 x 100 Mbit/s singlemode BFOC; redundant 24 V supply and signal contact 6GK5 101-1BC00-2AA3 E) E) Subject to export regulations: AL: N, ECCN: 5A991 9/22 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Communication Industrial Ethernet Passive network components: FastConnect IE FC Outlet RJ45 and IE FC RJ45 Modular Outlet ■ Overview Industrial Ethernet FastConnect (IE FC) is a fast assembly system with insulation displacement for easy assembly and wiring of 4-core and 8-core IE FC cables. Using the FC Stripping Tool it is possible to remove the outer casing and the woven shield of the IE FC cable accurately in a single step. The cable prepared in this manner is subsequently assembled on the contacts of the connection element. SCALANCE X-400 ■ Application IE FC RJ45 Modular Outlet Insert 1GE Connection elements The connection elements which can be used depend on whether the transmission rate is 10/100 Mbit/s or 1000 Mbit/s: • IE FC RJ45 Plug 90/180 (10/100 Mbit/s) in association with 4-core (2 x 2) IE FC cables • IE FC Outlet RJ45 (10/100 Mbit/s) in association with 4-core (2 x 2) IE FC cables • IE FC RJ45 Modular Outlet (10/100/1000 Mbit/s) with 8-core (4 x 2) IE FC cables The following table provides an overview of the available switches, the transmission rates they support, and the IE FC standard cables and IE FC connection elements which can be used. In addition to the IE FC standard cables, Catalog IK PI offers further IE FC cables with special properties. Switches X414-3E, X408-2, X310, X308-2, X308-2LD, X204 IRT, X202-2 IRT, X202-2P IRT, X201-3P IRT, X224, X216, X212-2, X212-2LD, X208, X206-1LD,X204-2, ESM X414-3E, X408-2 Port type 10/100BaseTX 1000BaseTX Transmission rate 10/100 Mbit/s 1.000 Mbit/s Max. cable length 100 m 100 m Cable type IE FC Standard Cable 2 x 2 IE FC Standard Cable 4 x 2 IE FC Standard Cable 4 x 2 Connection elements IE FC RJ45 Plug 90/180, alternative: IE FC Outlet RJ45 + TP Cord IE FC RJ45 Modular Outlet with insert 2FE + TP Cord IE FC RJ45 Modular Outlet with insert 1GE + TP Cord SIMATIC PCS 7 automation system IE FC Standard Cable 4x2 1000 Mbit/s connection IE FC RJ45 Modular Outlet Insert 1GE Alternatives for conversion from RJ45 to the insulation displacement system are the • IE FC Outlet RJ45 for 4-core TP (2 x 2) IE FC cables and transmission rates up to 100 Mbit/s and • IE FC RJ45 Modular Outlet for 8-core TP (4 x 2) IE FC cables and transmission rates up to 1000 Mbit/s. The latter has the advantage that the existing wiring can still be used if the communication is converted from 100 Mbit/s to 1000 Mbit/s. It is only necessary to replace the 2FE insert by one of type 1GE. In contrast to the plugs, an RJ45 patch cable (TP Cord) is additionally required for each outlet which connects this to the network components or data terminal. Detailed information on the FastConnect Outlets and the available TP Cords can be found in Catalog IK PI, Section "Industrial Ethernet", and in the A&D Mall, or in CA 01 under "Communication/networks / SIMATIC NET communication systems". Further information on network structures is provided in the manual for TP and fiber-optic networks. ■ Design IE FC RJ45 Plugs The IE FC RJ45 Plugs are the ideal solution for communication links with a transmission rate up to 100 Mbit/s. They permit simple, fast and direct assembly of the 4-core (2 x 2) twisted pair (TP) FastConnect installation cables in the field (without patch technology) up to a cable length of 100 m. Since the IE FC RJ45 Plugs have no parts which can be lost, assembly is also possible under difficult conditions. IE FC RJ45 plug with 90° outgoing cable (left) and with 180° outgoing cable (right) Siemens ST PCS 7 · November 2007 9/23 9 © Siemens AG 2007 Communication Industrial Ethernet Passive network components: FastConnect Industrial Ethernet FastConnect RJ45 Plugs are available in two versions: • with 180° (straight) outgoing cable, • with 90° (angled) cable outlet. They are used for optimized connection of Industrial Ethernet FastConnect cables to data terminals and network components. The plugs have a rugged, industry-compatible metal housing that provides optimum protection against faults in data communication. The 4 integral insulation displacement contacts permit simple, fault-free contacting of the various types of FC cable. Following introduction of the stripped ends of the cables into the tipped-up barrel contacts, the latter are pressed down for secure contacting of the conductors. The IE FC RJ45 Modular Outlet (Base Module) designed for transmission rates up to 1,000 Mbit/s consists of a rugged metal housing with IP40 degree of protection which is suitable for both DIN rail and wall mounting. It has 8 barrel contacts for connecting 8-core Industrial Ethernet FC installation cables and an interface for the replaceable insert, e.g.: • IE FC RJ45 Modular Outlet Insert 2FE with 2 x RJ45 sockets for 100 Mbit/s • IE FC RJ45 Modular Outlet Insert 1GE with 1 x RJ45 socket for 1,000 Mbit/s ■ Selection and Ordering Data Order No. Industrial Ethernet FC Standard Cable GP 2 x 2 For universal use, for connection to IE FC Outlet RJ45 or IE FC RJ45, 4-core (2 x 2), shielded 9 • Cut-to-length; max. delivery length 1,000 m, minimum ordering length 20 m 6XV1 840-2AH10 • Preferred length 1,000 m 6XV1 840-2AU10 Industrial Ethernet FC Standard Cable GP 4 x 2 For universal use, for connection to IE FC Modular Outlet RJ45, 8-core (4 x 2), shielded • Cut-to-length; max. delivery length 1,000 m, minimum ordering length 20 m 6XV1 870-2E Industrial Ethernet FC Stripping Tool Preadjusted stripping tool for fast stripping of Industrial Ethernet FC cables 6GK1 901-1GA00 Industrial Ethernet FC Blade Cassettes Spare blade cassettes for the FC stripping tool, 5 cassettes 6GK1 901-1GB00 9/24 ■ Selection and Ordering Data Order No. IE FC RJ45 Plug 180 RJ45 plug connector for Industrial Ethernet with a rugged metal housing and integrated insulation displacement contacts for connecting Industrial Ethernet FC installation cables; with 180° cable outlet; for network components and CPs/CPUs with Industrial Ethernet interface • 1 pack = 1 unit 6GK1 901-1BB10-2AA0 • 1 pack = 10 units 6GK1 901-1BB10-2AB0 • 1 pack = 50 units 6GK1 901-1BB10-2AE0 Industrial Ethernet FC RJ45 Plug 90 RJ45 plug connector for Industrial Ethernet with a rugged metal housing and integrated insulation displacement contacts for connecting Industrial Ethernet FC installation cables; with 90° cable outlet • 1 pack = 1 unit 6GK1 901-1BB20-2AA0 • 1 pack = 10 units 6GK1 901-1BB20-2AB0 • 1 pack = 50 units 6GK1 901-1BB20-2AE0 Industrial Ethernet FC Outlet RJ45 6GK1 901-1FC00-0AA0 IE FC RJ45 Modular Outlet with Insert 1GE FastConnect RJ45 Outlet for Industrial Ethernet with a replaceable insert for 1 x 1,000 Mbit/s interface 6GK1 901-1BE00-0AA2 IE FC RJ45 Modular Outlet with Insert 2FE FastConnect RJ45 Outlet for Industrial Ethernet with a replaceable insert for 2 x 100 Mbit/s interface For further IE FC RJ45 Modular Outlet versions and replaceable inserts, see Catalog IK PI 6GK1 901-1BE00-0AA1 Documentation Siemens ST PCS 7 · November 2007 Manual for TP and fiber-optic networks Network architecture, components, configurations, installation • German 6GK1 970-1BA10-0AA0 • English 6GK1 970-1BA10-0AA1 © Siemens AG 2007 Communication Industrial Ethernet Passive network components: ITP cables and connectors ■ Overview Electrical transmission media ■ Selection and Ordering Data Order No. ITP Standard Cable for Industrial Ethernet Not preassembled, cut-to-length 2 x 2-core, without connectors For connection of a terminal; for self-assembly of connectors or for the connection between patch panel and socket 6XV1 850-0AH10 ITP Standard Cable 9/15 ITP installation cable for direct connection of terminals with ITP interface to Industrial Ethernet network components with ITP interface; with a 9-pin and a 15-pin Sub-D plug •2m 6XV1 850-0BH20 •5m 6XV1 850-0BH50 •8m 6XV1 850-0BH80 Terminals can be connected through industrial twisted pairs (ITPs). The preassembled ITP standard cable with Sub-D connectors is available for connection between stations and network components. Line lengths of up to 100 m can be achieved while saving on patch technology. • 12 m 6XV1 850-0BN12 • 15 m 6XV1 850-0BN15 • 20 m 6XV1 850-0BN20 • 30 m 6XV1 850-0BN30 The ITP standard cable 9/15 is equipped with a 9-pin and a 15-pin connector. The cable is used for direct connection of terminals with ITP interface to Industrial Ethernet components with ITP interface. • 40 m 6XV1 850-0BN40 • 50 m 6XV1 850-0BN50 • 60 m 6XV1 850-0BN60 The ITP XP standard cable 9/9 is equipped with two 9-pin connectors. This cable is crossed for direct connection of two Industrial Ethernet network components with ITP interface. • 70 m 6XV1 850-0BN70 • 80 m 6XV1 850-0BN80 6XV1 850-0BN88 The ITP XP standard cable 15/15 is equipped with two 15-pin connectors. This cable is crossed for direct connection of two terminals with ITP interface. • 90 m • 100 m 6XV1 850-0BT10 The Industrial Ethernet ITP connectors have Sub-D connectors made of metal and are available in two versions: • 9-pin plug with straight cable outlet, for connection to OSM/ESM, OLM or ELM • 15-pin plug with variable cable outlet, for connection to terminals with ITP interface Alternatively, the terminals can also be connected to twisted pair (TP cord) cables. Detailed information on TP cord cables can be found in the IK PI catalog, in the A&D Mall or in CA 01 at "Communication/Networks / SIMATIC NET communication systems". 9 ITP XP Standard Cable 9/9 Crossed ITP installation cable for direct connection of two Industrial Ethernet network components with ITP interface; with two 9-pin Sub-D plugs •2m 6XV1 850-0CH20 •5m 6XV1 850-0CH50 •8m 6XV1 850-0CH80 • 12 m 6XV1 850-0CN12 • 15 m 6XV1 850-0CN15 • 20 m 6XV1 850-0CN20 • 30 m 6XV1 850-0CN30 • 40 m 6XV1 850-0CN40 ITP XP Standard Cable 15/15 Crossed ITP installation cable for direct connection of two terminals with ITP interface; with two 15-pin sub-D plugs •2m 6XV1 850-0DH20 •6m 6XV1 850-0DH60 • 10 m 6XV1 850-0DN10 ITP Connector for Industrial Ethernet • 9-pin, for connection to OSM/ESM, OLM or ELM 6GK1 901-0CA00-0AA0 • 15-pin, for connection to terminals with ITP interface 6GK1 901-0CA01-0AA0 Siemens ST PCS 7 · November 2007 9/25 © Siemens AG 2007 Communication Industrial Ethernet Passive network components: Fiber-optic cables ■ Overview Optical transmission media Glass fiber-optic cables are preferably used as the optical transmission medium. The two types of cable offered are suitable for above-ground routing indoors or outdoors. They are available in fixed lengths, precut/preassembled with 2 x 2 BFOC connectors (FIBER OPTIC standard cable) or 2 x 2 SC-connectors (FO Standard Cable). The FO Standard Cable with 2 x 2 SC connectors is required for optical networks in the Gigabit range, e.g. for implementing optical Gigabit Ethernet rings with SCALANCE X414-3E and MM492-2 media modules. X414-3E + MM492-2, X408-2 + MM492-2 X414-3E + MM491-2, X408-2 + MM491-2, X212-2, X212-2LD, X202-2 IRT, X206-1LD, X204-2, OSM Port type 1000BaseSX 100BaseFX Transmission rate 1000 Mbit/s 10/100 Mbit/s Max. cable length 750 m 3000 m Cable type FO Standard Cable Fiber optic standard cable FO multimode fiber type Connector type 50/125 µm 2 x 2 SC FO Standard Cable FIBER OPTIC Standard Cable Applications Universal cable for installation indoors and outdoors Delivery format Cut-to-length, pre-assembled with 4 BFOC(ST) or 4 SC connectors Cut-to-length, pre-assembled with 4 BFOC connectors (ST) Cable type (standard designation) AT-W(ZN)YY 2x1G50/125 AT-VYY 2G62.5/125 3.1B200 + 0.8F600 F Fiber type Multimode gradient fiber 50/125 mm Multimode gradient fiber 62.5/125 mm • At 850 nm ≤ 2.7 dB/km ≤ 3.1 dB/km • At 1300 nm ≤ 0.7 dB/km ≤ 0.8 dB/km Damping ■ Technical specifications Switches Cable type 62.5/125 µm 2 x 2 BFOC (ST) Modal bandwidth • At 850 nm ≥ 600 MHz × km ≥ 200 MHz × km • At 1300 nm ≥ 1200 MHz × km ≥ 600 MHz × km Number of fibers 2 2 Cable design Segmentable Segmentable outer conductor Core type Hollow core, filled Compact core • Basic element PVC, orange/black PVC, gray • Strain relief Aramide fiber Kevlar fiber and impregnated glass fiber Materials • Outer sheath/color PVC, green of cable 9 PVC, black Mechanical characteristics • Dimensions of basic element 2.9 mm diam. (3.5 ± 0.2) mm diam. • Cable dimensions 4.5 x 7.4 mm (6.3 × 9.8) ± 0.4 mm • Cable weight Approx. 40 kg/km Approx. 74 kg/km • Permissible tensile ≤ 500 N force • Bending radius 70 mm • Resistance to later- 300 N/cm al force ≤ 500 N (temporary) ≥ 100 mm only on the flat side – Permissible ambient conditions • Routing and instal- -5 ... +50 ºC lation temperature -5 ... +50 ºC • Operating temper- -25 ... +80 ºC ature -20 ... +60 ºC • Storage temperature -25 ... +80 ºC -25 ... +70 ºC Behavior in fire – Flame-retardant to IEC 60332-3 and VDE 0482-266-2-4 Silicone-free Yes Yes Resistance to mineral oils and grease Limited resistance – UL/CSA approvals OFNG, UL1651 FT4/IEEE1202 – UV-resistant Yes – Rodent protection – Yes • 1000BaseSX 750 m – • 1000BaseLX 2000 m – Gigabit length 9/26 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Communication Industrial Ethernet Passive network components: Fiber-optic cables Order No. Other lengths and other fiber-optic cables can be found in Catalog IK PI. •1m 6XV1 873-6AH10 •3m 6XV1 873-6DH30 •5m 6XV1 873-6DH50 Note: Supplementary components for the SIMATIC NET cable range can be ordered from your local contact person. For technical support, please contact: J. Hertlein, A&D SE PS Tel.: +49 911 750-4465 Fax: +49 911 750-9991 E-mail: juergen.hertlein@siemens.com • 10 m 6XV1 873-6AN10 • 20 m 6XV1 873-6DN20 • 50 m 6XV1 873-6DN50 • 100 m 6XV1 873-6AT10 • 200 m 6XV1 873-6AT20 • 300 m 6XV1 873-6GT30 ■ Selection and Ordering Data FO Standard Cable 50/125 1) Preferred lengths, preassembled with 2 x 2 SC connectors: Further information on assembly is provided in the manual for TP and fiber-optic networks. FIBER OPTIC CABLE standard cable 62.5/125, splittable 1) Preferred lengths, preassembled with 2 x 2 BFOC (ST) connectors: •1m 6XV1 820-5BH10 B) •3m 6XV1 820-5BH30 B) •5m 6XV1 820-5BH50 B) • 10 m 6XV1 820-5BN10 B) • 20 m 6XV1 820-5BN20 B) • 50 m 6XV1 820-5BN50 B) • 100 m 6XV1 820-5BT10 B) • 200 m 6XV1 820-5BT20 B) • 300 m 6XV1 820-5BT30 B) BFOC (ST) connector set For FIBER OPTIC CABLE standard cable, 20 units 6GK1 901-0DA20-0AA0 B) 9 B) Subject to export regulations: AL: N, ECCN: EAR99H 1) Special tools and specially trained personnel are required for pre-assembling glass fiber-optic cables. Siemens ST PCS 7 · November 2007 9/27 © Siemens AG 2007 Communication Industrial Ethernet System connection PCS 7 systems ■ Design Connection of single stations, servers and clients SIMATIC PCS 7 subsystems for engineering, operation and monitoring (also via Internet/Intranet), batch control, route control, asset management or IT applications are distributed between various SIMATIC PCS 7 Industrial Workstations of single station, server or client design depending on the configuration. Depending on their task and the associated integration into the complete system, these SIMATIC PCS 7 Industrial Workstations are connected either only on the plant bus, only on the OS LAN (terminal bus) or on both buses of the Industrial Ethernet network. The redundant or non-redundant connection is made using onboard interfaces, simple network cards or special communications processors (e.g. CP 1613). The CP 1613 communication delivered with SIMATIC PCS 7 Workstations for single stations and servers instead of BCE is a combination of CP 1613 communications processor and S7-1613 communications software. However, if fault-tolerant automation systems are used, ES/OS single stations and OS servers require the S7-REDCONNECT software instead of the S7-1613 communications software. ES/OS single stations and OS servers with S7-1613 communications software can be accordingly upgraded in this case using the S7-REDCONNECT Upgrade (see also page 9/28). Single stations and servers with BCE can also be subsequently upgraded to CP 1613 communication. Depending on the abovementioned criteria, either the S7-1613 communications software or the S7-REDCONNECT software is required in addition to the CP 1613 communications processor. Connection to OS LAN (terminal bus) SIMATIC PCS 7 Industrial Workstations in client, server or single station designs are connected as standard to the OS LAN via the onboard Industrial Ethernet interface. In the case of servers or single stations without a connection to the plant bus, the network card envisaged for BCE can be used as an alternative. The OS LAN can also have a redundant configuration, where two rings are connected together via two pairs of switches (see also "Introduction" at the beginning of the catalog section on Industrial Ethernet). A "SIMATIC PCS 7 Redundant Terminal Bus Adapter Package", comprising server and desktop adapter network cards, is required to connect the stations to the two rings of the redundant OS LAN. 9 Connection of automation systems CP 1613 Connection to plant bus Single stations and servers can be operated on the plant bus via Basic Communication Ethernet (network card plus BCE license) or CP 1613 communication. CP 1613 communication is always required for ES/OS single stations and OS servers if an operator system has more than 8 subordinate automation systems or if fault-tolerant automation systems are used. In all other cases, the more cost-effective Basic Communication Ethernet (BCE) can be used instead. BCE and CP 1613 communication is embedded in each case in an alternative SIMATIC PCS 7 Workstation for single station and server. The separately available desktop adapter network card can also be used for BCE. The BCE license is already included with SIMATIC PCS 7 Workstations. If you use alternative hardware instead for your stations, you require an additional BCE license for each station which communicates over the plant bus via BCE. 9/28 Siemens ST PCS 7 · November 2007 The SIMATIC PCS 7 automation systems communicate with other subsystems of the process control system (e.g. operator system or engineering system) via the Industrial Ethernet plant bus. The automation systems are connected to the plant bus using the CP 443-1 communications processor, also redundant in the case of fault-tolerant systems. © Siemens AG 2007 Communication Industrial Ethernet System connection PCS 7 systems ■ Selection and Ordering Data ■ Selection and Ordering Data Order No. System connection of single stations, servers and clients B) Desktop adapter network card for BCE and as spare part for redundant terminal bus INTEL PCI network card for connection to Industrial Ethernet (10/100/1000 Mbit/s), with RJ45 connection A5E00504378 SIMATIC PCS 7 Redundant Terminal Bus Adapter Package Server and desktop adapter for designing a redundant terminal bus, consisting of 2 Intel PCI network cards for connection to Industrial Ethernet (10/100/1000 Mbit/s), with RJ45 connection 6ES7 652-0XX01-1XF0 B) CP 1613 A2 PCI card for connection to Industrial Ethernet, with ITP and RJ45 connections 6GK1 161-3AA01 B) SIMATIC NET S7-1613/2006 for Industrial Ethernet S7 communications software for CP 1613, runtime software, in 2 languages (German, English), executes with Windows 2000 Professional/ 2000 Server/ XP Professional/ Server 2003, single license for 1 installation, software and electronic manual on CD-ROM, license key on diskette 6GK1 716-1CB64-3AA0 SIMATIC NET S7-REDCONNECT/2006 Software for fail-safe S7 communication over redundant networks, for CP 1613, runtime software, in 2 languages (German, English), executes with Windows 2000 Professional/ 2000 Server/ XP Professional/ Server 2003, single license for 1 installation, software and electronic manual on CD-ROM, license key on diskette 6GK1 716-0HB64-3AA0 SIMATIC NET S7-REDCONNECT/2006 Upgrade Software for expansion of S7-1613 to S7-REDCONNECT, runtime software, in 2 languages (German, English), executes with Windows 2000 Professional/ 2000 Server/ XP Professional/ Server 2003, single license for 1 installation, software and electronic manual on CD-ROM, license key on diskette 6GK1 716-0HB64-3AC0 Order No. System connection of single stations and servers which are not based on the SIMATIC PCS 7 Industrial Workstation PCS 7 BCE V7.0 Runtime license for plant bus communication via standard network card and Basic Communication Ethernet; already integrated in SIMATIC PCS 7 Industrial Workstations, in 3 languages (German, English, French), executes with Windows XP Professional or Windows Server 2003, floating license for 1 user Type of delivery: License key disk, certificate of license, terms and conditions 6ES7 650-1CD07-2YB5 System connection of automation systems CP 443-1 Communications processor for connection of SIMATIC S7-400 to Industrial Ethernet through TCP/IP, ISO and UDP; for S7 communication, S5-compatible communication (SEND/RECEIVE) with FETCH/WRITE with or without RFC 1006, diagnostics expansion, Multicast, commissioning through LAN 10/100 Mbit/s, with electronic manual on CD-ROM 6GK7 443-1EX11-0XE0 B) Subject to export regulations: AL: N, ECCN: EAR99H 9 Siemens ST PCS 7 · November 2007 9/29 © Siemens AG 2007 Communication Industrial Ethernet Industrial Wireless LAN (IWLAN) ■ Overview ■ Design SCALANCE W746-1PRO Ethernet client module OS clients SCALANCE X414-3 PCS 7 Web server OS-LAN (terminal bus) SCALANCE X204-2/X208 Redundant OS server Engineering station Access point SCALANCE W788-1PRO Mobile remote client with WLAN interface 9 Ethernet Client module SCALANCE W746-1PRO Stationary remote client SIMATIC PCS 7 allows you to integrate mobile or stationary remote clients into the OS-LAN (terminal bus) via a SCALANCE W788-1PRO access point. The following applications can be implemented in this manner: • Use of additional remote OS clients (1 or 2 on IWLAN) • Linking of Web clients to a SIMATIC PCS 7 Web server (1 or 2 on IWLAN) • Remote access to an engineering station with application of Remote Desktop (Windows XP or Server 2003 operating system) or PC Anywhere, e.g. during commissioning Mobile remote clients (e.g. notebooks) possessing a WLAN interface can communicate with the access point via it. Stationary remote clients in a desktop/tower housing (SIMATIC PCS 7 Industrial Workstations) require a SCALANCE W746-1PRO Ethernet client module for the IWLAN communication with the access point. SCALANCE W746-1PRO Ethernet client module and SCALANCE W788-1PRO access point are both very rugged, use state-of-the-art authentication and encryption procedures, and guarantee high reliability of the radio channel. Note: Please note that Industrial Wireless LAN is not approved of as a terminal bus (OS-LAN) or plant bus of SIMATIC PCS 7. 9/30 Siemens ST PCS 7 · November 2007 The SCALANCE W746-1PRO Ethernet client module is highly suitable for integrating devices with an Industrial Ethernet connection into Industrial Wireless LAN (IWLAN) radio networks with reliable communication. The SCALANCE W746-1PRO Ethernet client module handles the radio connection for a maximum of eight connected devices with Ethernet interface. If one of the connected devices is exchanged, the Ethernet client module recognizes this immediately and administers the new address. Special features of the SCALANCE W746-1PRO Ethernet client module • Versatile power supply facilities (operation on 100 V to 240 V AC network with PS791-1PRO power supply) • Antenna diversity for reliable reception in complex radio environments with two ANT795-4MR omnidirectional antennas screwed onto the housing, can be replaced by other types from the SCALANCE W700 range • Transmission rate up to 54 Mbit/s at 2.4 GHz and 5 GHz with radio approval in more than 30 countries • Conforms to the IEEE 802.11b/g and IEEE 802.11a standards • High reliability through reservation of data transfer rate with IWLAN communication with SCALANCE W788-1PRO access point • WPA and 128-bit encryption (AES) for high security against illegal access • Rugged metal enclosure resistant to shock and vibration, and with IP65 dust protection • Suitable for ambient temperatures from -20 to +60°C (resistant to condensation) For further information and detailed technical specifications, refer to Catalog IK PI, the A&D Mall or Catalog CA 01 under "Communication/networks, SIMATIC NET communication systems, Industrial mobile communication". © Siemens AG 2007 Communication Industrial Ethernet Industrial Wireless LAN (IWLAN) SCALANCE W788-1PRO access point ■ Integration The data and power connections for the SCALANCE W746-1PRO Ethernet client module and the SCALANCE W788-1PRO access point can be made using a hybrid cable or separate cables (preferably over short distances): • With separate cables, a 4-core TP (2 x 2) IE FC Standard Cable (type A) is used as the data cable. This Industrial Ethernet cable is connected on site to the supplied IP67 hybrid plug connector. A Power M12 Cable Connector PRO is additionally required for the power supply. IE FC Standard Cable and Power M12 Cable Connector PRO must be ordered in addition. SCALANCE W746-1PRO PC (remote client) The SCALANCE W788-1PRO access point is highly suitable for designing Industrial Wireless LAN (IWLAN) radio networks with reliable communication. It has an Industrial Ethernet interface for the connection to the wire-bound network. Special features of the SCALANCE W788-1PRO access point • Versatile power supply facilities (operation on 100 V to 240 V AC network with PS791-1PRO power supply) • Antenna diversity for reliable reception in complex radio environments with two ANT795-4MR omnidirectional antennas screwed onto the housing, can be replaced by other types from the SCALANCE W700 range • Transmission rate up to 54 Mbit/s at 2.4 GHz and 5 GHz with radio approval in more than 30 countries • Conforms to the IEEE 802.11b/g and IEEE 802.11a standards • WPA and 128-bit encryption (AES) for high security against illegal access • Rugged metal enclosure resistant to shock and vibration, and with IP65 dust protection • Suitable for ambient temperatures from -20 to +60°C (resistant to condensation) 24 V DC IE FC cable 2x2 with hybrid plug-in connector Power cable 2x0.75 with power M12 cable connector PRO Example of data and power supply connections using separate cables • If the data and power supply are connected using one cable, an FC Modular Outlet with power insert and the hybrid cable must be ordered in addition. The hybrid connector included in the scope of supply and the FC Modular Outlet with power insert can be assembled and connected on site. SCALANCE X-400 For further information and detailed technical specifications, refer to Catalog IK PI, the A&D Mall or Catalog CA 01 under "Communication/networks, SIMATIC NET communication systems, Industrial mobile communication". IE Hybrid cable connector 24 V DC IE FC RJ45 Modular Outlet Power Insert IE Hybrid Cable 2x2 + 4x0,34 SCALANCE W788-1PRO Example of data and power supply connections using a hybrid cable • If 100 ... 240 V AC is available on site, the PS791-1PRO power supply can be used (to be ordered in addition). It is supplied including AC connector and cable to the Ethernet client module/access point, but without AC cable. Siemens ST PCS 7 · November 2007 9/31 9 © Siemens AG 2007 Communication Industrial Ethernet Industrial Wireless LAN (IWLAN) ■ Selection and Ordering Data ■ Selection and Ordering Data Order No. Stationary remote client SCALANCE W746-1PRO IWLAN Ethernet client module with built-in radio interface; IEEE 802.11b/g/a radio networks at 2.4/5 GHz up to 54 Mbit/s. Country approvals; WPA/AES; Power over Ethernet (PoE), IP65 protection (-20 to +60 °C) for administration of the radio connection of up to eight linked devices with Industrial Ethernet connection Scope of delivery: Two ANT795-4MR antennas, IP67 hybrid connector, mounting material, manual on CD-ROM (German, English) • Country approvals for operation outside the USA and Canada 6GK5 746-1ST00-2AA6 G) • Country approvals for operation in the USA and Canada 6GK5 746-1ST00-2AB6 G) SCALANCE W788-1PRO IWLAN access point with built-in radio interface; IEEE 802.11b/g/a radio networks at 2.4/5 GHz up to 54 Mbit/s. Country approvals; WPA/AES; Power over Ethernet (PoE), IP65 protection (-20 to +60 °C) Scope of delivery: Two ANT795-4MR antennas, IP67 hybrid connector, mounting material, manual on CD-ROM (German, English) 6GK5 788-1ST00-2AA6 G) • Country approvals for operation in the USA and Canada 6GK5 788-1ST00-2AB6 G) Components for system connection Data and power connection via separate lines IE FC Standard Cable GP 2 x 2 4-core (2 x 2), shielded TP installation cable for universal use, can be connected to IE FC Outlet RJ45/IE FC RJ45 Plug; cut-tolength; max. delivery unit 1000 m, minimum ordering quantity 20 m 6XV1 840-2AH10 Power M12 Cable Connector PRO Socket for connection of SCALANCE W-700 for 24 V DC supply; 4-pole, a-coded, with mounting instructions, 3 units 6GK1 907-0DC10-6AA3 6XV1 870-2J IP 67 hybrid connector (1 unit included in delivery of SCALANCE W746/788) Plug for connection of SCALANCE W-700 to Industrial Ethernet and Power over Ethernet (PoE), with mounting instructions, 1 unit 09 45 125 1300.001) PS791-1PRO power supply AC/DC power supply, 10 W, IP65 (-20 to +60°C), input: 90 to 265 V AC, output: 24 V DC, metal enclosure Scope of delivery: AC power 3+PE cable connector, DC power cord M12, mounting material, operating instructions (German, English) 6GK5 791-1PS00-0AA6 G) For antennas and further accessories for access points and Ethernet client modules, refer to Catalog IK PI, the A&D Mall or Catalog CA 01 under "Communication/networks, SIMATIC NET communication systems, Industrial mobile communication" G) Subject to export regulations: AL: N, ECCN: 5A002ENC3 1) Order directly from: HARTING Deutschland GmbH & Co KG P.O. Box 2451 D-32381 Minden Tel. +49 571-8896-0 Fax. +49 571-8896-354 E-mail: de.sales@HARTING.com Internet: www.HARTING.com Further information on country approvals Additional information is available in the Internet under: http://www.siemens.com/simatic-net/ik-info Data and power connection via common line 9/32 IE Hybrid Cable 2x2 + 4x0.34 4-core, shielded installation cable; cut-to-length; max. delivery unit 1000 m, minimum ordering quantity 20 m Accessories • Country approvals for operation outside the USA and Canada IE FC Standard Cable GP 2 x 2 4-core (2 x 2), shielded TP installation cable for universal use, can be connected to IE FC Outlet RJ45/IE FC RJ45 Plug; cut-tolength; max. delivery unit 1000 m, minimum ordering quantity 20 m 6GK1 901-1BE00-0AA3 Power supply for 100 to 240 V AC Access point 9 Order No. IE FC RJ45 Modular Outlet with Power Insert Fast Connect RJ45 Modular Outlet for Industrial Ethernet with a power insert for 1 x 24 V and 1 x 100 Mbit/s interface 6XV1 840-2AH10 Siemens ST PCS 7 · November 2007 ■ More information Note: Supplementary components for the SIMATIC NET cable range can be ordered from your local contact person. Technical advice on this subject is available from: J. Hertlein A&D SE PS Tel. +49 (0)911/750 44 65 Fax. 0911/750 99 91 E-mail: juergen.hertlein@siemens.com © Siemens AG 2007 Communication Industrial Security Introduction ■ Overview INTERNET Enterprise Resource Planning (ERP) INTERNET Firewall INTERNET Manufacturing Execution System (MES) Firewall Firewall Terminal bus 1 (OS-LAN) Terminal bus 2 (OS-LAN) Plant bus 1 Plant bus 2 Security cell Security cell Example of "defense in depth" security architecture The progressive standardization, opening and networking of control systems has been accompanied by an enormous increase in security risks. The potential dangers arising from destructive programs such as computer viruses, worms or trojans or from access by unauthorized personnel range from network overloads or failures, theft of passwords and data, to unauthorized access to the process automation. Apart from material damage, specifically targeted sabotage can also have dangerous consequences for people and the environment. ■ Function With its pioneering security concept, SIMATIC PCS 7 offers comprehensive solutions for safeguarding a process engineering plant that are based on a hierarchical security architecture (defense in depth). The special feature of this concept is its integrated approach. It is not just restricted to the use of individual security methods (e.g. encryption) or devices (e.g. firewalls). Its strengths lie more in the interaction of a host of security measures in the plant network. The security concept is described in detail in the manual "SIMATIC PCS 7 recommendations and information", and comprises advice and recommendations (best practices) on the following topics: • Creation of a network architecture with defense in depth, combined with the segmentation of the plant into security cells • Network administration with name resolution, assignment of IP addresses and division into subnetworks • Operation of plants in Windows domains (active directory) • Administration of the Windows and SIMATIC PCS 7 operator privileges; integration of the SIMATIC PCS 7 operator privileges into the Windows administration • Reliable control of the clock synchronization in the Windows network • Management of security patches for Microsoft products • Use of antivirus software and firewalls • Support and remote access (VPN, IPSec) On the system side, SIMATIC PCS 7 V7.0 supports the implementation of guidelines and recommendations of the security concept by means of: • Compatibility with the current versions of the antivirus software: Trend Micro OfficeScan, Symantec Norton AntiVirus and McAfee Virusscan • Application of the local Windows XP firewall • SIMATIC security control (SSC) for automatic setting of safetyrelated parameters of DCOM, registry and Windows firewall during the setup • User administration and authentication by means of SIMATIC Logon • Integration of the SCALANCE S602, S612 and S613 industrial security modules of SIMATIC NET The manual "SIMATIC PCS 7 Security Concept, Recommendations and Advice" is available on the Internet via the SIMATIC Guide for Technical Documentation under "SIMATIC PCS 7 Process Control Systems & Migration". You can find the SIMATIC Guide for Technical Documentation on the Internet. Additional information is available in the Internet under: http://www.siemens.com/simatic-docu Siemens ST PCS 7 · November 2007 9/33 9 © Siemens AG 2007 Communication Industrial Security Industrial Security components ■ Overview Configuration Using the supplied configuration tool, it is easy to create and configure the security modules which are to communicate securely with one another. You do not require any special IT knowledge. The complete configuration can be saved on the optional swap medium C-PLUG (order separately) and transmitted to another security module. This permits easy and fast replacement of modules in the event of a fault. ■ Selection and Ordering Data Order No. SCALANCE S industrial security modules The SCALANCE S industrial security modules can safeguard industrial systems/devices or network segments of an Ethernet against unauthorized access by means of a firewall. Some of them, e.g. SCALANCE S612 and S613, additionally use encryption and authentication (VPN) to protect the data transmission between systems/devices or network segments against data manipulation and espionage. ■ Design SCALANCE S industrial security modules 9 The following SCALANCE S industrial security modules can be used in the context of the SIMATIC PCS 7 security concept: • SCALANCE S602 industrial security module with firewall functionality • SCALANCE S612 industrial security module with firewall functionality and VPN (Virtual Private Network) functionality for up to 32 devices (up to 64 simultaneous VPN tunnels) • SCALANCE S613 industrial security module with firewall functionality and VPN (Virtual Private Network) functionality for up to 64 devices (up to 128 simultaneous VPN tunnels); suitable for extended temperature range from -20 to +70 °C. Security functions of the SCALANCE S industrial security modules • Firewall functionality (S602, S612 and S613) - Filtering of data packets as well as enabling or blocking of communication links on the basis of filter lists (packet filter firewall); IP and MAC addresses can be filtered, as well as communication protocols (ports) with incoming and outgoing communication. - Saving of access data in a log file; for verification purposes and for recognition of attacks and derivation of preventive measures. • VPN functionality (S612 and S613) - Secure authentication (identification) of the network notes through monitoring and checking the incoming data traffic using proven VPN mechanisms. - Data encryption and data integrity checking for protection against espionage and data manipulation; establishment of VPN tunnels to other security modules 9/34 Siemens ST PCS 7 · November 2007 SCALANCE S602 Industrial security module for protection against unauthorized access by means of Stateful Inspection Firewall 6GK5 602-0BA00-2AA3 F) SCALANCE S612 Industrial security module for protection against unauthorized access by means of Stateful Inspection Firewall as well as for protection of up to 32 devices per VPN tunnel (up to 64 VPN tunnels simultaneously) 6GK5 612-0BA00-2AA3 F) SCALANCE S613 Industrial security module for protection against unauthorized access by means of Stateful Inspection Firewall as well as for protection of up to 64 devices per VPN tunnel (up to 128 VPN tunnels simultaneously); suitable for extended temperature range from -20 to +70° C 6GK5 613-0BA00-2AA3 F) 6GK1 900-0AB00 B) Accessories C-PLUG Swap medium for simple replacement of devices in event of fault; for saving of configuration and application data, can be used in SIMATIC NET products with C-PLUG slot B) Subject to export regulations: AL: N, ECCN: EAR99H F) Subject to export regulations: AL: N, ECCN: 5D002ENC3 Note: For further components and accessories, especially cable material and connectors as well as tools and supplementary material for assembly, refer to page 9/23, 9/25 and 9/26 as well as to Catalog IK PI. © Siemens AG 2007 Communication PROFIBUS Introduction ■ Overview ■ Benefits Industrial Ethernet Automation system Long distances with fiber-optic PROFIBUS DP OLM OLM PROFIBUS PA DP/PA link Ex isolation + repeater PROFIBUS DP RS 485-iS coupler Communication at field level with PROFIBUS Distributed peripherals such as remote I/O stations with their I/O modules, transmitters, drives, valves or operator terminals communicate with the automation systems (controllers) at field level through a powerful real-time bus system. This communication is characterized by: • Cyclic transmission of process data • Acyclic transfer of interrupts, parameters and diagnostics data PROFIBUS is predestined for these tasks because it enables high-speed communication with the intelligent distributed I/Os by means of a communications protocol (PROFIBUS DP) as well as communication and simultaneous power supply for transmitters and actuators (PROFIBUS PA). PROFIBUS is simple, rugged and reliable, can be expanded online by further distributed components, and can be used in both standard environments and hazardous areas. It supports the coexistence of field devices from different vendors on one line (interoperability) as well as the vendor-independent exchangeability of devices from one profile family. SIMATIC PCS 7 utilizes the benefits of the PROFIBUS from start to finish: 7 Small planning and engineering overheads as well as low commissioning costs 7 Optimum distributed system structure with low hardware and space requirements 7 Significantly reduced overhead for wiring, jumpering, distribution, power supply and field mounting 7 High-speed communication with high measurement accuracy 7 Efficient engineering, interoperability and replaceability of devices through vendor-independent device description 7 Short commissioning times through short loop tests, easy parameterization and the elimination of calibration work 7 Bidirectional communication and high amounts of information permit enhanced diagnostics functions for fast fault locating and troubleshooting 7 Optimum life cycle management through processing and evaluation of diagnostics and status information by an asset management system ■ Function Users have numerous facilities for communication and line diagnostics, as well as for diagnostics of the intelligent field devices connected. Furthermore, the PROFIBUS is fully integrated into the global asset management of the SIMATIC PCS 7 process control system. In addition to all these properties, the following PROFIBUS functions are particularly relevant to process automation: • Integration of previously installed HART devices • Redundancy • Safety-related communication with PROFIsafe up to SIL 3 according to IEC 61508 • Clock synchronization • Time tagging On account of its exceptional characteristics, PROFIBUS is now established in all sectors of the production, process and hybrid industries and has become the most successful open field bus in the world. PROFIBUS transmission systems PROFIBUS DP 7 RS 485: simple and low-cost electrical transmission system based on shielded two-wire cable. 7 RS 485-iS: intrinsically-safe electrical transmission system for hazardous areas up to Ex zone 1, implemented using a shielded two-wire cable with a transmission rate of 1.5 Mbit/s. 7 Fiber-optic: optical transmission system with glass or plastic fiber-optic cables, for fast transmission of large quantities of data in environments with high interferences or for covering long distances. PROFIBUS PA 7 MBP (Manchester Coded; Bus Powered): intrinsically-safe transmission system which permits simultaneous transmission of digital data and powering of the field devices on a single two-wire cable. It is suitable for direct connection of devices in environments up to Ex zone 1 or 21 and associated sensors/actuators in environments up to Ex zone 0 or 20. Siemens ST PCS 7 · November 2007 9/35 9 © Siemens AG 2007 Communication PROFIBUS DP Introduction ■ Application a SIMATIC PCS 7 automation system through internal interfaces in the CPU, and up to 10 PROFIBUS DP lines through additional CP 443-5 Extended communications processors. On a PROFIBUS DP line it is possible to operate up to 125 devices, and on a bus segment up to 31 devices with PROFIBUS DP interface (32 stations). Electrical and optical transmission technologies offer many different configuration options for PROFIBUS DP networks. Electrical networks can span up to approx. 10 km. With optical transmission systems, the total size of the network is governed primarily by the cycle times as a result of the almost loss-free transmission. The PROFIBUS DP fieldbus enables the SIMATIC PCS 7 automation systems (controllers) to communicate with distributed I/Os from the ET 200 range (remote I/Os) as well as with field/process devices, CPUs/CPs and operator terminals that have a PROFIBUS DP interface. It is possible to route the PROFIBUS DP into Ex zone 1 by using a fieldbus isolating transformer (RS 485-iS coupler) and the RS 485-iS transmission technology. Connection of the intelligent, distributed field/process devices and operator terminals on PROFIBUS PA to the automation system takes place likewise through PROFIBUS DP. Depending on the type of automation system and the number of available slots, up to 4 PROFIBUS DP lines can be connected to With SIMATIC PCS 7, PROFIBUS DP topologies are always implemented through the standard electrical PROFIBUS DP connection on the automation system in the form of electrical or mixed (electrical/optical) networks. In the case of mixed networks, the transition between the two media is implemented by an optical link module (OLM). As regards communication between the stations, there is no difference between electrical twowire technology and fiber optic technology. Electrical networks can be configured with a line or tree topology. Mixed electrical/optical networks with OLMs as routers can be configured with a line, ring or star topology. ■ Technical specifications PROFIBUS DP 9 Data transmission RS 485 RS 485-iS Fiber-optic Transmission rate 9.6 kbit/s ... 12 Mbit/s 9.6 kbit/s ... 1.5 Mbit/s 9.6 kbit/s ... 12 Mbit/s Cable 2-wire shielded 2-wire shielded Plastic as well as multi-mode and single-mode glass-fiber EEx(ib) Type of protection Line, tree Topology Line 1) Ring, star, line Nodes per segment 32 32 Nodes per network (with repeater) 126 126 126 1000 m at 187.5 kbit/s1) 400 m at 500 kbit/s1) 200 m at 1.5 Mbit/s1) Max. 80 m (plastic) 2-3 km (multi-mode glass-fiber) >15 km at 12 Mbit/s (single-mode glass-fiber) Max. 91) Not relevant Cable length per segment depen- 1200 m at max. 93.75 kbit/s dent on transmission rate 1000 m at 187.5 kbit/s 400 m at 500 kbit/s 200 m at 1.5 Mbit/s 100 m at 12 Mbit/s Repeater for signal refreshing with RS 485 networks 1) Max. 9 According to PROFIBUS installation guideline 2.262 9/36 Siemens ST PCS 7 · November 2007 – © Siemens AG 2007 Communication PROFIBUS DP Electrical networks ■ Overview Shielded twisted-pair cables are used as the transmission medium for electric PROFIBUS DP networks. The PROFIBUS DP stations are connected to these bus lines through a bus connector (max. 32 stations per segment). ■ Design Active RS 485 terminating element The active RS 485 terminating element is used to terminate bus segments. The component supplied with 24 V DC independent of the bus stations provides a defined RS 485 signal level, and suppresses reflections on the line. Bus stations (e.g. ET 200S) can be coupled and decoupled without feedback to/from PROFIBUS networks terminated by active RS 485 terminating elements. RS 485-iS coupler The RS 485-iS coupler is an isolating transformer with which the PROFIBUS DP fieldbus can be routed intrinsically-safe into the hazardous area. The RS 485-iS coupler has the following functions: • Connection of intrinsically-safe PROFIBUS DP stations, e.g. ET 200iSP, ET 200iS or devices from other vendors with Ex i DP connection • Conversion of the electrical PROFIBUS DP RS 485 transmission technology into the intrinsically-safe RS 485-iS transmission technology with a transmission rate of 1.5 Mbit/s • Suitable as a safety barrier • Additional use as a repeater in the hazardous area. The RS 485-iS coupler as an open unit can only be used in housings, cabinets or rooms for electrical equipment. It is assembled on a SIMATIC S7-300 rail which can be positioned horizontally or vertically. FastConnect Stripping Tool FastConnect PROFIBUS FastConnect is a system for fast and easy assembly of PROFIBUS copper cables. The system comprises compatible components: • FastConnect Standard Cable for fast assembly • FastConnect Stripping Tool with FastConnect Blade Cassettes (spare blade cassettes for the stripping tool) • FastConnect bus connector for PROFIBUS The RS 485-iS coupler is integrated into the PROFIBUS as follows: • Connection to standard PROFIBUS DP via standard Sub-D socket (at the bottom on the RS 485-iS coupler, behind the right front door). • Connection of PROFIBUS DP with RS 485-iS transmission technology via screw terminals (at the top of the RS 485-iS coupler, behind the right front door) • The last bus station on the intrinsically-safe PROFIBUS DP segment (not further RS 485-iS couplers) must be terminated by a selectable resistance using the connector, Order No. 6ES7 972-0DA60-0XA0. Repeater for PROFIBUS A repeater links the individual bus segments with RS 485 technology. Main applications are: • Increase in number of nodes and distances • Electrical isolation of segments If diagnostics functions for physical cable diagnostics are required in addition to the standard repeater functionality, a diagnostics repeater can be alternatively used. It additionally performs physical online monitoring of the copper bus cables. In the event of a fault it sends a diagnostic message with detailed information about the type and location of the fault to the DP master. Siemens ST PCS 7 · November 2007 9/37 9 © Siemens AG 2007 Communication PROFIBUS DP Electrical networks ■ Selection and Ordering Data PROFIBUS FastConnect Standard Cable Standard type with special design for fast mounting, 2-core, shielded, cut-to-length Specify length in m Max. delivery unit 1000 m, minimum order quantity 20 m Order No. 6XV1 830-0EH10 Preferred lengths 9 ■ Selection and Ordering Data Order No. RS 485-IS Coupler Isolating transformer for connection of PROFIBUS DP segments with RS 485 and RS 485-iS transmission technologies 6ES7 972-0AC80-0XA0 PROFIBUS connector with selectable terminating resistor For connection of IM 152 to PROFIBUS DP with RS 485-iS transmission technology 6ES7 972-0DA60-0XA0 B) - 20 m 6XV1 830-0EN20 - 50 m 6XV1 830-0EN50 S7-300 rail Lengths: - 100 m 6XV1 830-0ET10 • 160 mm 6ES7 390-1AB60-0AA0 - 200 m 6XV1 830-0ET20 • 482 mm 6ES7 390-1AE80-0AA0 - 500 m 6XV1 830-0ET50 • 530 mm 6ES7 390-1AF30-0AA0 - 1000 m 6XV1 830-0EU10 • 830 mm 6ES7 390-1AJ30-0AA0 Other PROFIBUS cables See Catalog IK PI • 2000 mm 6ES7 390-1BC00-0AA0 PROFIBUS FastConnect Stripping Tool Preadjusted stripping tool for fast stripping of PROFIBUS FastConnect bus cables 6GK1 905-6AA00 B) Subject to export regulations: AL: N, ECCN: EAR99H PROFIBUS FastConnect Blade Cassettes Spare blade cassettes for PROFIBUS FastConnect stripping tool, 5 units 6GK1 905-6AB00 Note: For further information on electrical PROFIBUS networks as well as components and accessories, particularly cable material for special applications, refer to Catalog IK PI, Chapter "PROFIBUS", Section "Electrical networks with OLM". PROFIBUS FastConnect bus connector RS 485 with 90° cable outlet With insulation displacement system, max. data transfer rate 12 Mbit/s • Without PG interface 6ES7 972-0BA50-0XA0 • With PG interface 6ES7 972-0BB50-0XA0 PROFIBUS FastConnect bus connector RS 485 Plug 180 With 180° cable outlet, with insulation displacement system, for connection of PC, PG, OP 6GK1 500-0FC00 Other bus connectors See Catalog IK PI RS 485 Repeater for PROFIBUS Data transfer rate max. 12 Mbit/s, 24 V DC, IP 20 housing 6ES7 972-0AA01-0XA0 RS 485 Diagnostic Repeater For connection of 1 or 2 segments to PROFIBUS DP; with online diagnostics functions for monitoring of bus cables 6ES7 972-0AB01-0XA0 Active RS 485 Terminating Element for PROFIBUS For terminating bus segments for data transfer rates from 9.6 kbit/s to 12 Mbit/s 6ES7 972-0DA00-0AA0 9/38 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Communication PROFIBUS DP Optical networks with glass fiber-optic cables ■ Overview We recommend use of glass fiber optic cables with 2 multi-mode fibers for optical PROFIBUS networks in indoor and outdoor areas. The standard FIBER OPTIC CABLE is available in fixed lengths for distances up to 2000 m, preassembled with 4 BFOC connectors. A BFOC connector set with 20 connectors is available as an accessory. Further fiber optic cables can be found in Catalog IK PI, Chapter "PROFIBUS", Section "Optical networks with OLM". Optical Link Module Optical Link Modules (OLM) permit the construction of optical and hybrid (electrical/optical) networks in line, ring or star topology. The maximum distance between two OLMs can be up to 15 km for OLMs of type G12-1300 (see Catalog IK PI) and glass fiber optic cables with single-mode fibers (on request). The PROFIBUS OLM/G12 used as standard is equipped with one RS 485 interface and two glass fiber optic cable interfaces (4 BFOC sockets). The fiber optic line length between two OLMs of this type can be up to 3000 m when using the standard FIBER OPTIC CABLE. The OLMs have a compact metal housing suitable for DIN rail assembly. They automatically recognize all PROFIBUS data transfer rates. Faults can be rapidly located as follows: • Display of module status via floating signaling contact • Checking of FO link quality (loss per section) via test output for optical receivers for logging and plausibility checks. ■ Selection and Ordering Data Order No. FIBER OPTIC CABLE Standard glass FO cable, splittable Pre-assembled with 4 BFOC connectors Preferred lengths •1m 6XV1 820-5BH10 B) •5m 6XV1 820-5BH50 B) • 10 m 6XV1 820-5BN10 B) • 20 m 6XV1 820-5BN20 B) • 50 m 6XV1 820-5BN50 B) • 100 m 6XV1 820-5BT10 B) Other lengths and cables See Catalog IK PI BFOC Connector Set1) For standard and trailing FIBER OPTIC CABLES, 20 units 6GK1 901-0DA20-0AA0 B) PROFIBUS OLM/G12 V4.0 Optical link module with 1 x RS 485 and 2 x glass FOC interfaces (4 BFOC sockets), for standard distances up to 3000 m, with signal contact and measuring output 6GK1 503-3CB00 B) B) Subject to export regulations: AL: N, ECCN: EAR99H 1) Note: Additional components of the SIMATIC NET wiring range can be ordered from your local contact person. For technical advice contact: J. Hertlein, A&D SE PS Tel.: +49 911 750-4465, Fax: +49 911 750-9991 E-mail: juergen.hertlein@siemens.com Siemens ST PCS 7 · November 2007 9/39 9 © Siemens AG 2007 Communication PROFIBUS DP Optical networks with plastic fiber-optic cables ■ Overview SIMATIC NET plastic/PCF fiber-optic cables can be used to design optical PROFIBUS DP networks inside buildings. For AS interfacing of ET 200M with exclusively F modules, plastic/PCF fiber-optic cables are an alternative if compliance with safety integrity level SIL 3 is required for the safety-related application. Using plastic/PCF fiber-optic cables, the ET 200M systems are connected to the electrical bus cable of the PROFIBUS DP via optical bus terminals (OBT). The advantage of this configuration is that the isolating module essential for signal decoupling between the IM and the F modules in the case of a direct electrical connection of the ET 200M (only F modules in a rack with IM 153-2) can be omitted. Safety-related automation system IM 153-2 ET 200M with standard I/O modules PROFIBUS DP copper cable IM 153-2 FO OBT 9 ET 200M with safetyrelated F modules OBT Plastic Fiber Optic Cable OBT for PROFIBUS DP Using the OBT (optical bus terminal) for PROFIBUS, it is possible to connect a PROFIBUS DP station with integrated optical interfaces to an RS 485 segment or a PROFIBUS DP station without integrated optical interface. Plastic/PCF fiber-optic cables can be used for the optical connection between the PROFIBUS DP station with integrated optical interface and the OBT. ■ Design ■ Selection and Ordering Data Order No. PROFIBUS OBT Optical bus terminal for connecting a PROFIBUS station or an RS 485 segment without integrated optical interface to the optical PROFIBUS; without simplex connector 6GK1 500-3AA00 PROFIBUS Plastic Fiber Optic, standard cable Robust round cable with 2 plastic fiber optic cores, PVC external sheath and PA internal sheath, without connectors, for indoor use, cut-to-length 6XV1 821-0AH10 PROFIBUS Plastic Fiber Optic, duplex core Plastic fiber optic cable with 2 cores, PVC sheath, without connectors, for use in environments with low mechanical stress, 50-m ring 6XV1 821-2AN50 B) PROFIBUS Plastic Fiber Optic, Simplex Connector/Polishing Set 100 simplex connectors and 5 polishing sets for assembling PROFIBUS plastic fiber optic cables for the optical PROFIBUS DP 6GK1 901-0FB00-0AA0 B) PROFIBUS Plastic Fiber Optic, Stripping Tool Set To remove the external or core sleeve of plastic fiber optic cables 6GK1 905-6PA10 B) Connection Adapter Pack of 50, for using simplex connectors with the integrated FO interfaces (e.g. IM 153-2 FO); for 25 modules 6ES7 195-1BE00-0XA0 B) Subject to export regulations: AL: N, ECCN: EAR99H We particularly recommend the following plastic/PCF standard cables for implementing optical networks in indoor areas: • PROFIBUS Plastic Fiber Optic standard cable: - Rugged round cable with purple PVC outer casing and Kevlar tension-relief elements as well as plastic fibers with rugged polyamide inner casing. - Easy to assemble on site with 2 x 2 Simplex connectors - Cable lengths up to 50 m • PROFIBUS PCF Fiber Optic standard cable: - Preassembled, rugged round cable with purple PVC outer casing and Kevlar tension-relief elements as well as two PCF fibers (Polymer Optical Fiber) - Cannot be assembled on site - Cable lengths up to 300 m Further SIMATIC NET plastic/PCF fiber optic cables can be found in Catalog IK PI, Chapter "PROFIBUS", Section "Optical networks with OBT and integrated interface". 9/40 The following components are available for on-site assembly of the PROFIBUS Plastic Fiber Optic standard cable: • Simplex connector/polishing set (set with 100 simplex connectors and 5 polishing sets) • Stripping tool set for removing the outer casing and core casing • You require additional plug adapters for connecting cables with Simplex connectors to devices with integrated FO interfaces (e.g. IM 153-2 FO). Siemens ST PCS 7 · November 2007 Note: For further information on optical PROFIBUS networks as well as components and accessories, particularly cable material for special applications, refer to Catalog IK PI, Chapter "PROFIBUS", Section "Optical networks with OLM" and "Optical networks with OBT and integral interface". © Siemens AG 2007 Communication PROFIBUS DP AS connection ■ Overview ■ Selection and Ordering Data Order No. CP 443-5 Extended Communications processor for connection of SIMATIC S7-400 to PROFIBUS as DP master or for S7 communication, for data set routing of SIMATIC PDM 6GK7 443-5DX04-0XE0 IF 964-DP Interface module for connection of another PROFIBUS DP line, for plugging into a free DP module slot of the CPU 6ES7 964-2AA04-0AB0 PROFIBUS DP lines can be connected to a SIMATIC PCS 7 automation system (controller) via up to 4 internal interfaces in the CPU and up to 10 additional CP 443-5 Extended communications processors. If a module slot provided in the CPU for the PROFIBUS connection is still vacant, an IF 964-DP interface module is required in addition. When using data set routing with SIMATIC PDM, use of the CP 443-5 Extended communications processor is essential for the PROFIBUS connection. ■ Benefits 9 Advantages of the CP 443-5 Extended communications module: • Compact design; 9-contact Sub-D socket for connection to PROFIBUS DP • Simple installation Can be plugged into AS rack slot; connection to the other S7-400 modules via backplane bus • Operation without fan; backup battery or memory submodule are not required Siemens ST PCS 7 · November 2007 9/41 © Siemens AG 2007 Communication PROFIBUS DP Y-Link ■ Overview ■ Selection and Ordering Data Y-Link For connection of devices with only one PROFIBUS DP interface to a fault-tolerant automation system, comprising: • 2 IM 153-2 High Feature interface modules • 1 Y-coupler • 1 BM IM 157 bus module (IM/IM) • 1 BM Y-coupler bus module Order No. 6ES7 197-1LA11-0XA0 PS 307 load power supply Including connection assembly; 120/230 V AC; 24 V DC The Y-link is a bus coupler for transition from a redundant PROFIBUS DP master system to a single-channel PROFIBUS DP master system. It can be used for connecting devices with only one PROFIBUS DP interface to the redundant PROFIBUS DP master system AS 414H/ AS 417H. Fault-tolerant automation system 9 Y-Link redundant PROFIBUS DP 6ES7 307-1BA00-0AA0 • 5 A; 80 mm wide 6ES7 307-1EA00-0AA0 • 5 A, extended temperature range; 80 mm wide 6ES7 307-1EA80-0AA0 • 10 A, 200 mm wide 6ES7 307-1KA01-0AA0 PS 305 load power supply 24/48/60/110 V DC; 24 V DC • 2 A, extended temperature range; 80 mm wide 6ES7 305-1BA80-0AA0 B) Subject to export regulations: AL: N, ECCN: EAR99H ■ Design Connection of non-redundant PROFIBUS DP devices to redundant PROFIBUS DP The Y-link comprises: • Two IM 153-2 High Feature interface modules for extended temperature range • One Y-coupler incl. RS 485 repeater • One IM 157 (IM/IM) bus module for two IM 153-2 High Feature modules, for extended temperature range • One BM Y-coupler bus module Evaluation of the Y-Link diagnostics (and hence indirectly of the connected DP standard slaves) is supported by driver blocks. It is recommendable to have a redundant -24 V DC supply for the Y-Link, e.g. with two PS 307/PS 305 load power supplies. 9/42 • 2 A; 50 mm wide Siemens ST PCS 7 · November 2007 B) © Siemens AG 2007 Communication PROFIBUS PA Introduction ■ Overview You can define the degree of redundancy separately for the controller, fieldbus and I/O levels of your plant depending on the automation task and the derived safety requirements, and match them to the field instrumentation (Flexible Modular Redundancy, FMR). You can find an overview of the redundant architectures of PROFIBUS PA under "Design". The PROFIBUS PA is based on electrical transmission components. A shielded two-wire cable is used for digital data transmission and for the power supply. With line, tree and ring topologies, it is possible to configure networks with spur lines up to 120 m and bus segments up to approx. 1.9 km for operating environments up to Ex zone 2. With bus segments for hazardous areas in line with zone 1, the max. possible length per spur line is reduced to 30 m and per bus segment to 1 km. The line lengths actually achievable in practice depend on the number of PA devices and their current consumption. Bus segments are terminated either automatically (with active field distributors AFD in the case of ring topologies) or with the passive terminating element for PROFIBUS PA (SpliTConnect terminator). Direct interfacing of the devices in the field, especially in the hazardous area, together with the information content of the communication, are of significant importance in the process industry. PROFIBUS PA, which permits both digital data transmission and the power supply on a two-wire line with the intrinsically-safe MBP transmission technology (Manchester Coded; Bus Powered) is tailored to these requirements. It is optimally suitable for direct integration of the pneumatic actuators, solenoid valves and sensors positioned in operating environments up to Ex zone 1 or 0 into the process control system. The typical response time of a transmitter of approx. 10 ms indicates that short cycle times can be achieved with the PROFIBUS PA even in the case of a segment configuration with up to 31 devices. Practically all typical applications of the process industry can be implemented - both with small or large plant distances. Bidirectional communication and high information content allow enhanced diagnostics for fast and exact fault detection and elimination. The standardized communications services guarantee interoperability and replaceability between multi-vendor field devices and remote parameterization of the field devices during operation. The PROFIsafe profile allows seamless integration of safety communication into the PROFIBUS PA. You need not configure a separate safety bus for your safety-related applications. The PROFIBUS PA with the PROFIsafe profile is incorporated in "Safety Integrated for Process Automation". This comprehensive range of products and services from Siemens for failsafe, faulttolerant applications in the process industry offers you attractive and cost-effective alternatives to separate safety systems. The DP/PA Link is preferred for the gateway from PROFIBUS PA to PROFIBUS DP. When using the DP/PA Link, the transmission rate on the PROFIBUS DP is independent of the subordinate PROFIBUS PA segments. The configuration of the DP/PA Link depends on the operating environment (Ex zone) or the selected redundancy architecture. The types of coupler described in the Section "Gateways - DP/PA link and DP/PA coupler" are used for the configuration. With a small amount of data (small quantity framework) and low timing requirements, the DP/PA coupler can also be operated in stand-alone mode as a gateway. ■ Benefits Advantages provided by distributed field automation with application of the PROFIBUS PA profile included low hardware overhead, cost-effective engineering, increased operational safety and problem-free maintenance. These advantages are underlined by the following features: • Modularity and uniformity from the sensor up to the control level permit new plant concepts • Implementation of intrinsically-safe applications through use of the fieldbus in hazardous areas • Flexible Modular Redundancy (FMR) from the automation system (controller) down to the PROFIBUS PA field device with redundant architectures for environments up to Ex zone 2 (ring and line topologies with coupler redundancy) • Safety-related and fault-tolerant applications with low device and cabling overheads • Reduced configuration costs through simple, central engineering of the field devices (PROFIBUS PA and HART with SIMATIC PDM, also cross-vendor) • Simple installation using two wire cable for common power supply and data transmission • Reduced commissioning costs through simplified loop check • Low servicing costs thanks to simple wiring and comprehensive diagnostics facilities Siemens ST PCS 7 · November 2007 9/43 9 © Siemens AG 2007 Communication PROFIBUS PA Introduction ■ Design Ring architecture Active field distributors (AFD) integrate PROFIBUS PA field devices via 4 short-circuit proof spur line connections into a PROFIBUS PA ring with automatic bus termination. The PROFIBUS PA ring is connected to two FDC 157-0 DP/PA couplers of a DP/PA router. The DP/PA router can be operated on a single or redundant PROFIBUS DP. Up to 8 AFDs can be configured per ring. Direct fieldbus interfacing AS 414FH/ AS 417FH DP/PA Link PROFIBUS DP PROFIBUS PA DP/PA Link with redundant DP/PA couplers Active field splitter PROFIBUS PA DP/PA Link with redundant DP/PA couplers Active field distributors PROFIBUS PA Basic PROFIBUS PA design versions when using the DP/PA link as the router 9 Basic PROFIBUS PA design versions are presented at this point. In these configuration examples, DP/PA links are used in each case as the DP/PA router. Up to 5 DP/PA couplers can be operated in a DP/PA link. Mixed configurations (e.g. line and ring on one link) are also possible. The DP/PA router can also be implemented with a DP/PA coupler. In this case, the PROFIBUS DP connection is directly on the coupler instead of per interface module. Linear architecture with single coupler In this design version, each PROFIBUS PA line is linked with one DP/PA coupler of a DP/PA router. Depending on the operating environment, you can use either the FDC 157-0 DP/PA coupler (up to Ex zone 2) or the Ex [i] DP/PA coupler (up to Ex zone 1). The DP/PA router can be connected to a single or redundant PROFIBUS DP. Linear architecture with redundant couplers The active field splitter (AFS) connects a PROFIBUS PA line with two FDC 157-0 DP/PA couplers of a DP/PA router. This router is operable on a single or redundant PROFIBUS DP. The AFS switches the PROFIBUS PA line to the active one of the two redundant couplers. Flexible Modular Redundancy is possible at the device level by grouping individual devices in different PROFIBUS PA lines. Only one PROFIBUS PA line can be configured with coupler redundancy on each DP/PA router. A PROFIBUS PA ring cannot then be operated on this router. 9/44 Siemens ST PCS 7 · November 2007 Flexible Modular Redundancy is possible at the device level by grouping individual devices on different AFDs. Only one ring can be configured on each DP/PA router. A PROFIBUS PA line with coupler redundancy cannot then be operated on this router. The following limits must be observed for a PROFIBUS PA ring with respect to the configuration with PROFIBUS PA devices: • Max. 31 PROFIBUS-PA devices • Max. current consumption of all PROFIBUS-PA devices: 1 A Particular advantages of the ring architecture: • High availability • Transparent redundancy management of the intelligent FDC 157-0 DP/PA couplers for the higher-level system • Active bus terminations for automatic bus termination in the FDC 157-0 DP/PA couplers and the AFDs permit: - Automatic, bumpless isolation of defective sub-segments in event of short-circuit or wire breakage - Changing of the ring configuration and the instrumentation during operation, including addition or removal of ring segments • Safety-related and fault-tolerant applications with low device and cabling overheads ■ Technical specifications PROFIBUS PA Data transmission MBP Transmission rate 31.25 Mbit/s Cable 2-wire shielded Type of protection EEx(ia/ib) Topology Line, tree, ring PA devices per segment/coupler 31 PA devices per DP/PA link 64 Cable length per segment dependent on transmission rate 1900 m: standard 1900 m: EEx(ib) 1000 m: EEx(ia) © Siemens AG 2007 Communication PROFIBUS PA Routers: DP/PA link and DP/PA coupler ■ Overview ■ Application The two DP/PA routers are based on two versions of the DP/PA coupler: • Ex [i] DP/PA coupler (max. output current 110 mA) for implementation of PROFIBUS PA networks with a line or tree topology in environments up to Ex zone 1, not for redundant architectures (coupler redundancy, ring) • FDC 157-0 DP/PA coupler (max. output current 1000 mA) for implementation of PROFIBUS PA networks with a line, tree or ring topology in environments up to Ex zone 2; can be used for the redundant architectures "Ring" and "Coupler redundancy" DP/PA couplers are also integral components of the DP/PA link (see design). The DP/PA link connects PROFIBUS DP and PROFIBUS PA together, and decouples the transmission rates. In contrast to the DP/PA coupler which limits the data transmission rate on the PROFIBUS DP to 45.45 kbit/s, the DP/PA link does not influence the performance of the PROFIBUS DP. To create a smooth network transition between PROFIBUS DP and PROFIBUS PA, the SIMATIC product range offers two versions: the DP/PA coupler and the DP/PA link. The following criteria can be applied when choosing the network transition: • DP/PA coupler: For small quantity frameworks (volumes of data) and low timing requirements; limiting of data transfer rate on the PROFIBUS DP to 45.45 kbit/s • DP/PA link: For large number of stations and high cycle time requirements; data transfer rate on the PROFIBUS DP up to 12 Mbit/s The DP/PA link functions as a slave on the PROFIBUS DP and as a master on the PROFIBUS PA. From the viewpoint of the host PROFIBUS DP master, the DP/PA link is a modular slave whose modules are the devices connected on the PROFIBUS PA. Addressing of these devices is carried out indirectly via the DP/PA link which itself only requires one node address. The host PROFIBUS master can scan devices connected to the DP/PA link all at once. If the router is a DP/PA coupler, the nodes on the PROFIBUS PA are directly addressed by the PROFIBUS DP master (controller). The DP/PA coupler is an electrical node, but is transparent for communication between the master and PA field devices; it therefore does not require setting of parameters or addresses (exception: FDC 157-0 DP/PA coupler used as PROFIBUS diagnostics slave). PROFIBUS diagnostics with FDC 157-0 DP/PA coupler, configured as PROFIBUS diagnostics slave FDC 157-0 DP/PA couplers configured as PROFIBUS diagnostics slaves supply extensive diagnostic and status information via PROFIBUS for swift location and clearance of faults: • I&M data (Identification & Maintenance) • Current and voltage values on the main cable • Redundancy status • Wire breakage • Short-circuit • Signal level For this purpose, each FDC 157-0 DP/PA coupler requires its own PROFIBUS address. This applies independent of use in a DP/PA link or as a DP/PA router. The DP/PA link and DP/PA couplers as DP/PA routers can be mounted on an S7-300 profile rail. They are operated with 24 V DC, and can be installed in environments up to Ex zone 2 with extended temperature range. Siemens ST PCS 7 · November 2007 9/45 9 © Siemens AG 2007 Communication PROFIBUS PA Routers: DP/PA link and DP/PA coupler ■ Design High Speed solution with DP/PA link 2 Low-cost solution with direct addressing PROFIBUS master S7-400 2 4 up to 12 Mbit/s 5 45.45 kbit/s PROFIBUS DP DP/PA coupler PROFIBUS PA 3 DP/PA link PROFIBUS PA 2 31.25 kbit/s 1 3 4 3 DP/PA link • IM 153-2 interface module (single/redundant) • DP/PA couplers (max. 5 per IM 153-2) • Slave on DP side - master on PA side • Max. 64 PA devices (244 bytes I/O data) 4 5 6 7 8 DP/PA coupler • transparent for communication • Ex version 13.5 V / 110 mA • Non-Ex version 31 V / 1000 mA Configuration examples with DP/PA link and DP/PA coupler DP/PA link: 9 The DP/PA link is a modular combination consisting of the IM 153-2 High Feature PROFIBUS DP interface module (with optional redundancy) and up to 5 DP/PA couplers (Ex [i] or FDC 157-0) packaged in an S7-300 design. All components of the DP/PA link are interconnected through the S7 backplane bus. Use of active bus modules on the backplane allows hot swapping of individual modules and redundancy of the IM 153-2 High Feature PROFIBUS DP interface modules and the FDC 157-0 DP/PA coupler. The PS 307 or PS 305 load power supply can be used for the 24 V DC. With a redundant IM 153-2 High Feature interface module for PROFIBUS DP, it is also recommendable to have a redundant 24 V DC supply, e.g. with two PS 307/PS 305 load power supplies. The PROFIBUS PA lines/rings designed with the DP/PA couplers are physically separated as regards current input, but form one bus system in communication terms. A PROFIBUS PA ring or a PROFIBUS PA line with coupler redundancy can be operated on each DP/PA link. Further PROFIBUS PA lines can be operated on this DP/PA link using individual couplers. The FDC 157-0 DP/PA couplers provided for the ring coupling or coupler redundancy must always be located at the right-hand end of a sequence of up to 5 couplers. 9/46 Siemens ST PCS 7 · November 2007 The following basic components are available to configure the DP/PA link: • IM 153-2 High Feature interface module for extended temperature range • DP/PA coupler (Ex [i] and FDC 157-0) • Components for redundant design and for hot swapping - DIN rail for hot swapping (as an alternative to the standard DIN rail) - BM PS/IM for 1 load power supply and 1 IM 153-2 High Feature module - IM/IM (IM 157) bus module for two IM 153-2 High Feature modules, for redundant and non-redundant design and for extended temperature range - DP/PA bus module for one DP/PA coupler Ex [i] or FDC 157-0, for extended temperature range (up to 5 DP/PA couplers possible per DP/PA link) - DP/PA but module for 2 DP/PA coupler FDC 157-0, for extended temperature range Additive option: • PS 307 load power supply for 120/230 V AC; 24 V DC, version in 2, 5 or 10 A, or PS 305 load power supply for 24/48/60/110 V DC; 24 V DC, 2A © Siemens AG 2007 Communication PROFIBUS PA Routers: DP/PA link and DP/PA coupler ■ Technical specifications DP/PA coupler IM 153-2 High Feature (for extended temperature range) Connection for PROFIBUS PA Linking of PROFIBUS DP (9.6 kbit/s to 12 Mbit/s, slave functionality) and PROFIBUS PA with support of the "Configuration in Run" function The DP/PA link function is only implemented by extending the IM 153-2 High Feature with one or more DP/PA couplers. Standalone operation of the IM 153-2 High Feature is not possible. 1 Y coupler, up to 5 DP/PA couplers or up to 64 slaves can be connected Isolation from the higher-level DP master system Function • DP/PA coupler Ex [i] 2 terminals of a 4-pole screw-type terminal, integral terminating resistor • DP/PA coupler FDC 157-0 4-pole screw-type terminal for connection and looping through, selectable terminating resistor Connection for PROFIBUS DP 9-pin Sub-D plug, contact assignment as described in IEC 61158/EN 50170 Backplane bus Connection through S7 backplane bus connector (only necessary for DP/PA link); non-floating The active BM DP/PA bus modules are required for the hot swapping function Diagnostic displays • DP/PA coupler Ex [i] and DP/PA coupler FDC 157-0 Bus activity "DP" (yellow) Bus activity "PA" (yellow) 24 V DC "ON" (green) • Additive with DP/PA coupler FDC 157-0 Group fault "SF" (red) Bus fault "BF" (rot) DP/PA coupler activated, feeding/transmitting "ACT" (yellow), only with PA redundancy Power supply 24 V DC (20.4 V ... 28.8 V) Current consumption • DP/PA coupler Ex [i] Max. 400 mA • DP/PA coupler FDC 157-0 Max. 2300 mA Voltage at coupler output Interfaces • Connection for PROFIBUS DP 9-pin Sub-D plug, contact assignment as described in IEC 61158/EN 50170, Vol. 2 • Backplane bus Connection through S7 backplane bus connector, non-floating Bus modules and profile rails for hot swapping are required for the hot swapping function and for a redundant PROFIBUS DP interface module. Diagnostic displays Group fault "SF" (red) Bus fault DP "BF 1" (red) Bus fault PA "BF 2" (red) IM active "ACT" (yellow) 24 V DC "ON" (green) Power supply 24 V DC Current consumption Max. 100 mA (in DP/PA link) Max. 200 mA (in Y-link) 9 • DP/PA coupler Ex [i] 13 V ... 14 V DC • DP/PA coupler FDC 157-0 31 ± 1 V DC Power loss Approx. 2 W (in DP/PA link) Approx. 4 W (in Y-link) 110 mA Voltage failure bridging 20 ms 1 A (up to 50 °C), 0.8 A (up to 60 °C) Mechanical design of power supply 4-pin screw terminal, shortcircuiting link between PE and M24; the short-circuiting link must be removed for floating operation (independent of this, the DP interface is always floating) Max. current at coupler output • DP/PA coupler Ex [i] • DP/PA coupler FDC 157-0 Power loss • DP/PA coupler Ex [i] Approx. 7 W • DP/PA coupler FDC 157-0 Approx. 13.4 W Permissible operating temperature -25 ... +60 °C (horizontal installation) -25 ... +40 °C (vertical installation) -25 ... +60 °C (horizontal installation) -25 ... +40 °C (vertical installation) Dimensions (W x H x D) in mm 40 x 125 x 130 Weight Approx. 350 g Operating temperature • DP/PA coupler Ex [i] and DP/PA coupler FDC 157-0 Dimensions (W x H x D) in mm 80 x 125 x 130 Weight Approx. 515 g Siemens ST PCS 7 · November 2007 9/47 © Siemens AG 2007 Communication PROFIBUS PA Routers: DP/PA link and DP/PA coupler ■ Selection and Ordering Data ■ Selection and Ordering Data Order No. Active bus modules for hot swapping • DP/PA coupler Ex [i] 6ES7 157-0AD82-0XA0 • DP/PA coupler FDC 157-0, redundant design possible 6ES7 157-0AC83-0XA0 B) IM 153-2 High Feature Interface module for DP/PA Link and Y-Link; for extended temperature range 6ES7 153-2BA82-0XB0 B) Accessories PS 307 load power supply Including connection assembly; 120/230 V AC; 24 V DC • 2 A; 50 mm wide 6ES7 307-1BA00-0AA0 • 5 A; 80 mm wide 6ES7 307-1EA00-0AA0 • 5 A, extended temperature range; 80 mm wide 6ES7 307-1EA80-0AA0 • 10 A, 200 mm wide 6ES7 307-1KA01-0AA0 PS 305 load power supply 24/48/60/110 V DC; 24 V DC • 2 A, extended temperature range; 80 mm wide Order No. Components for hot swapping and for redundant design DP/PA coupler For transition from RS 485 to MBP 6ES7 305-1BA80-0AA0 Standard profile rails (without hot swapping function) • 482 mm wide (19 inches) 6ES7 390-1AE80-0AA0 • 530 mm wide 6ES7 390-1AF30-0AA0 9 • BM PS/IM for one load power supply and one IM 153-2 High Feature module 6ES7 195-7HA00-0XA0 • BM IM 157 For two IM 153-2 High Feature modules, for redundant and non-redundant configuration, for extended temperature range, for hot swapping function, permissible operating temperature -25...+60 °C 6ES7 195-7HD80-0XA0 • BM DP/PA For one DP/PA coupler Ex [i] or FDC 157-0, for extended temperature range, for hot swapping function, permissible operating temperature -25 to +60 °C 6ES7 195-7HF80-0XA0 • BM DP/PA For two DP/PA couplers FDC 157-0, for extended temperature range, for hot swapping function, permissible operating temperature -25 to +60 °C 6ES7 195-7HG80-0XA0 Profile rail for hot swapping For max. 5 active bus modules • 482 mm wide (19 inches) 6ES7 195-1GA00-0XA0 • 530 mm wide 6ES7 195-1GF30-0XA0 • 620 mm wide 6ES7 195-1GG30-0XA0 B) Subject to export regulations: AL: N, ECCN: EAR99H 9/48 Siemens ST PCS 7 · November 2007 B) © Siemens AG 2007 Communication PROFIBUS PA Active field distributor AFD and active field splitter AFS ■ Overview Active field distributor AFD and active field splitter AFS Diagnostic displays Status PA main line PA1, PA2 (green) Fault PA main line PA1, PA2 (red) Status/fault PA spur line X1 to X4 (green) Permissible operating temperature -25 ... +70 °C Dimensions (W x H x D) in mm 120 x 57 x 80 Weight Approx. 700 g Active field splitter AFS Connection of PROFIBUS PA field devices • Max. 31 per line • Operating environment up to zone 2 or 22 • Max. current consumption of all devices 1 A Power supply 16 V DC (16 ... 32 V) Current consumption Approx. 20 mA Power loss Approx. 600 mW Active field distributor AFD Output voltage for PA section 31 V ± 1 V DC An active field distributor (AFD) can integrate up to 4 PROFIBUS PA field devices via short-circuit proof spur line connections into a PROFIBUS PA ring with automatic bus termination. The PROFIBUS PA ring is connected to two FDC 157-0 DP/PA couplers of a DP/PA router. Up to 8 AFDs and up to 31 PROFIBUS PA devices can be configured per ring. The number of PROFIBUS PA devices is additionally limited by the max. current consumption of 1 A for all devices. Voltage failure bridging 5 ms Output current for PA section (for dimensioning of device configuration) 1A Diagnostic displays Status PA main line PA1, PA2 (green) Fault PA main line PA1, PA2 (red) Permissible operating temperature -25 ... +70 °C Dimensions (W x H x D) in mm 120 x 57 x 80 Weight Approx. 700 g An AFD can be replaced during operation. The function of the PROFIBUS PA devices on the other AFDs is not influenced by this. 9 Active field splitter AFS The active field splitter (AFS) connects a PROFIBUS PA line with two redundant FDC 157-0 DP/PA couplers of a DP/PA router. The AFS switches the PROFIBUS PA line to the active one of the two redundant couplers. Up to 31 PROFIBUS PA devices can be connected on the PROFIBUS PA line. This number is additionally limited by the max. current consumption of 1 A for all devices. ■ Technical specifications Active field distributor AFD and active field splitter AFS Active field distributor AFD Connection of PROFIBUS PA field devices • Max. 4 per AFD • Max. 31 per ring • Operating environment up to zone 2 or 22 • Max. current consumption of all devices 1 A Current Imax. per spur line X1 to X4 60 mA Power supply 16 V DC (16 ... 32 V) Current consumption Approx. 20 mA Power loss Approx. 600 mW Output voltage for PA section 31 V ± 1 V DC Voltage failure bridging 5 ms Output current for PA section (for dimensioning of device configuration) 1A ■ Selection and Ordering Data Order No. Active field distributor AFD with 4 short-circuit-proof spur line connections for integration of field devices 6ES7 157-0AF81-0XA0 B) Active field splitter AFS for connecting a PROFIBUS PA line to 2 redundant FDC 157-0 DP/PA couplers; automatic switchover to the active coupler 6ES7 157-0AF82-0XA0 B) Profile rail adapter for an active field distributor AFD or active field splitter AFS, optional 6ES7 157-0AF83-0XA0 B) Subject to export regulations: AL: N, ECCN: EAR99H Siemens ST PCS 7 · November 2007 9/49 © Siemens AG 2007 Communication PROFIBUS PA FastConnect/SpliTConnect ■ Overview ■ Selection and Ordering Data PROFIBUS FC process cables, color-coded for the various applications (Ex, non-Ex area) are available for designing field bus networks in accordance with IEC 61158-2 (e.g. PROFIBUS PA). • Blue for Ex applications 6XV1 830-5EH10 The FastConnect stripping tool can be used to strip the FC process cable for PROFIBUS PA to the correct length for casing and shield. • Black for non-Ex applications 6XV1 830-5FH10 ■ Design SpliTConnect terminator DP/PA link SpliTConnect coupler SpliTConnect taps FC Process cable SpliTConnect M12 Jack 9 Order No. FC Process Cable 2-core, shielded SpliTConnect M12 Outlet for direct connection of PA field devices to the SpliTConnect tap Connector on PA field device SpliTConnect The SpliTConnect Tap enables the design of fieldbus segments according to IEC 61158-2 with field device connection points. The SpliTConnect Coupler can be used to construct a PROFIBUS PA hub by connecting SpliTConnect Taps in series. By replacing the contacting screw by the SpliTConnect Terminator, the SpliTConnect Tap can be used as a bus terminating element. Terminal equipment can be connected directly through the FC process cable. Using the SpliTConnect M12 Outlet, PA field devices can also be connected to the SpliTConnect Tap by an M12 connection. The SpliTConnect M12 Jack is a connecting element between an FC process cable and an M12 connector on the PROFIBUS PA field device. For details on SpliTConnect network components, see Catalog IK PI. 9/50 Siemens ST PCS 7 · November 2007 Sold by the meter: Max. delivey unit 1000 m, minimum ordering quantity 20 m PROFIBUS FastConnect Stripping Tool Stripping tool for rapid stripping of insulation from PROFIBUS FastConnect bus cables 6GK1 905-6AA00 PROFIBUS FastConnect Blade Cassettes Spare blade cassettes for the PROFIBUS FastConnect stripping tool, 5 pcs 6GK1 905-6AB00 SpliTConnect Tap For design of PROFIBUS PA segments and connection of PA field devices, insulation displacement system, IP67, 10 pcs 6GK1 905-0AA00 SpliTConnect M12 Outlet Replacement element for direct connection of PA field devices to the SpliTConnect Tap, 5 pcs 6GK1 905-0AB10 SpliTConnect Coupler Connection element for cascading SpliTConnect Taps in order to configure star points, 10 pcs 6GK1 905-0AC00 SpliTConnect Terminator For termination of PROFIBUS PA segments, 5 pcs • Terminator (Ex); use possible in hazardous area 6GK1 905-0AD00 • Terminator (non-Ex); use not possible in hazardous area 6GK1 905-0AE00 SpliTConnect M12 Jack Connection element between FC process cable and M12 plug on the PROFIBUS PA field device, 5 pcs 6GK1 905-0AF00 © Siemens AG 2007 Communication Other communication AS-Interface ■ Overview ■ Selection and Ordering Data 6GK7 343-2AH00-0XA0 Front Connector 20-pin, with screw contacts 6ES7 392-1AJ00-0AA0 The actuator-sensor interface (AS-Interface) is a multi-vendor networking system for simple - usually binary - actuators and sensors in the lowest field area. AS-Interface enables a wiring loom with parallel wiring to be replaced by a simple two-wire cable shared by all sensors or actuators. CP 343-2 Manual Including software and examples The AS-Interface works by the master-slave principle. Sensors/ actuators connected through the AS-Interface cable are controlled by the master as slaves. Note: AS-Interface is integrated in SIMATIC pcs 7 as a subordinate bus. Consequently, this bus does not offer the full functionality of SIMATIC PCS 7; this applies in particular to diagnostics functions. Further information, see Catalog IK PI. ■ Design Order No. CP 343-2 Communications processor for connection of SIMATIC S7-300 and ET 200M to AS-Interface, without front connector • German 6GK7 343-2AH00-8AA0 • English 6GK7 343-2AH00-8BA0 • French 6GK7 343-2AH00-8CA0 • Italian 6GK7 343-2AH00-8EA0 DP/AS-Interface Link 20E PROFIBUS DP/ AS-Interface gateway, degree of protection IP 20 6GK1 415-2AA01 Manual for DP/AS-Interface Link 20E Paper version incl. type and GSD files • German 6GK1 971-2DS01-0AA0 • English 6GK1 971-2DS01-0AA1 • French 6GK1 971-2DS01-0AA2 • Spanish 6GK1 971-2DS01-0AA3 • Italian 6GK1 971-2DS01-0AA4 9 System components The basic components of a system installation are: • CP 343-2 AS-Interface master module for ET 200M or/and DP/AS-Interface link for connection of an AS-Interface line to PROFIBUS DP • AS-Interface shaped cable (use of round cable also possible if preferred) • Modules for connecting standard sensors/actuators • Power supply unit for powering the slaves • Actuators and sensors with an integrated slave ASIC • Address programming device for setting the slave address Siemens ST PCS 7 · November 2007 9/51 © Siemens AG 2007 Communication Other communication Modbus ■ Overview ■ Selection and Ordering Data CP 341 communications processor with one RS 232 C (V.24) interface Order No. 6ES7 341-1AH01-0AE0 RS 232 connecting cable for linking to SIMATIC S7 •5m 6ES7 902-1AB00-0AA0 • 10 m 6ES7 902-1AC00-0AA0 • 15 m 6ES7 902-1AD00-0AA0 CP 341 communications processor with one 20 mA (TTY) interface 6ES7 341-1BH01-0AE0 20 mA (TTY) connecting cable for linking to SIMATIC S7 Modbus is connected to PROFIBUS DP using an ET 200M with a CP 341 communications processor. The latter enables the fast and efficient exchange of data through point-to-point coupling. The CP 341 communications module is available in 3 versions with different transmission physics: • RS 232C (V.24) • 20 mA (TTY) • RS 422/RS 485 (X.27) 9 The MODBUS Master or MODBUS Slave loadable drivers are needed for the Modbus coupling. •5m 6ES7 902-2AB00-0AA0 • 10 m 6ES7 902-2AC00-0AA0 • 50 m 6ES7 902-2AG00-0AA0 CP 341 communications processor with one RS 422/485 (X.27) interface 6ES7 341-1CH01-0AE0 RS 422/485 connecting cable for linking to SIMATIC S7 •5m 6ES7 902-3AB00-0AA0 • 10 m 6ES7 902-3AC00-0AA0 • 50 m 6ES7 902-3AG00-0AA0 Loadable drivers for CP 341 MODBUS master (RTU format) • Single license 6ES7 870-1AA01-0YA0 • Single license, without software or documentation 6ES7 870-1AA01-0YA1 MODBUS slave (RTU format) 9/52 Siemens ST PCS 7 · November 2007 • Single license 6ES7 870-1AB01-0YA0 • Single license, without software or documentation 6ES7 870-1AB01-0YA1 © Siemens AG 2008 Automation systems 10/2 Introduction 10/4 Microbox automation system 10/7 Standard automation systems 10/15 Fault-tolerant automation systems 10/24 Safety-related automation systems Siemens ST PCS 7 · Update Nov 2008 © Siemens AG 2008 Automation systems Introduction ■ Overview Various automation systems are available with a price/performance ratio which can be tailored to your system requirements. The CPU of the automation systems is already equipped as standard with an onboard PROFIBUS DP fieldbus connection. Depending on the type of CPU, 1 or 2 further PROFIBUS DP interfaces are possible using additional IF 964-DP interface modules. PROFIBUS communication modules can be additionally fitted if required. AS 417 AS 416 AS 414 SIMATIC PCS 7 AS RTX Microbox automation system with software controller Standard automation systems of S7-400 series with hardware controller Scalable automation systems, overview The SIMATIC PCS 7 process control system offers a wide range of automation systems whose performances are finely matched to one another within wide limits. This results in fine scaling of the automation performance over the complete performance range. The automation systems offered can be differentiated according to various criteria. In accordance with the design, they are categorized as: • Microbox automation system with software controller • Modular automation systems of the S7-400 range with hardware controller ■ Application 10 Microbox automation system The SIMATIC PCS 7 AS RTX Microbox automation system represents the starter system in the lower performance range of SIMATIC PCS 7. As a result of its exceptional physical properties and small dimensions, it is particularly suitable for use at plant level in industrial applications. Modular automation systems of the S7-400 range In these "Automation system bundles", selected components of the SIMATIC S7-400 are combined together. The following characteristics make the SIMATIC S7-400 predestined for use as a SIMATIC PCS 7 automation system: 7 Modular design without fans 7 High expansion capability and ruggedness 7 Single or redundant design 7 Comprehensive communication facilities 7 Integral system functions 7 Integrable safety functions (Safety Integrated) 7 Simple linking of central or distributed I/O In accordance with their functionalities, the modular automation systems of the S7-400 range can be classified into: • Standard automation systems • Fault-tolerant automation systems • Safety-related automation systems 10/2 Siemens ST PCS 7 · Update November 2008 ■ Design Microbox automation system The compact and rugged automation system based on the SIMATIC Microbox PC 427B has been designed for maintenance-free 24-hour continuous operation at ambient temperatures up to 55 °C. Since there are no fans or rotating storage media, it is resistant to vibration and shock. The Windows XP Embedded operating system, the WinAC RTX controller software, and the SIMATIC PC DiagMonitor diagnostics software are preinstalled on the supplied 2-GB CompactFlash card. The scope of delivery also includes an AS runtime license for 250 POs. Modular automation systems of the S7-400 range The SIMATIC PCS 7 automation systems of the S7-400 range are delivered as preassembled and tested all-in-one systems (AS bundles) at no extra charge. Each of these AS bundles is already combined with a SIMATIC PCS 7 AS Runtime license for 100 process objects (PO). The configuration of the AS bundles and their Order Nos. can be individually combined by selecting preconfigured ordering units. System-specific ordering configurations are available for this purpose in the Sections "Standard automation systems", "Fault-tolerant automation systems" and "Safety-related automation systems". In order to facilitate selection of preferred configurations, these are additionally listed with their complete Order Nos. As an alternative to this catalog for ordering the AS bundles, a configurator offered in the catalog & online ordering system "A&D Mall" (www.siemens.com/automation/mall) can also be used. Depending on the configuration as Single Station or Redundant Station, an AS bundle is equipped with the following components: • 1 or 2 racks with 9 or 18 slots • 1 or 2 SIMATIC S7-400 CPUs • 1, 2 or 4 PS 405 (24 V DC) or PS 407 (120/230 V AC/DC) power supplies, without backup batteries in each case • 1 or 2 x RAMs from 768 KB to 30 MB • 1 or 2 memory cards with 2 to 16 MB RAM • 1, 2 or 4 interface modules for Industrial Ethernet plant bus (via CP or integrated in CPU) • Additive PROFIBUS communications processors (by means of configurator up to 4 per Single Station, up to 8 per Redundant Station) • 4 sync modules for a range up to 10 m or 10 km and 2 fiberoptic sync cables, 1 m (longer lengths can be ordered separately) © Siemens AG 2008 Automation systems Introduction ■ Technical specifications AS 412 H/F/FH AS 414-3IE AS 414-3 AS 414 H/F/FH AS 416-2 AS 416-3 AS 416-3IE AS 417-4 AS 417 H/F/FH AS 417-4 AS 417 H/F/FH Memory card [in MB] 2 2/4 4 8/16 16 4 16 Analog value measurements 10 35 125 125 125 150 700 Digital value measurements 15 110 350 350 350 400 1.200 PID controls 6 35 110 110 110 130 300 Motors 10 50 125 125 125 150 450 Valves 10 50 125 125 125 150 450 SFC 0 15 40 40 40 50 200 Steps 0 150 400 400 400 500 2.000 Dosing 0 3 15 15 15 15 45 Digital inputs DI 50 220 800 800 800 850 2.000 Digital outputs DO 25 110 300 300 300 315 1.000 Analog inputs AI 20 80 250 250 250 275 800 Analog outputs AO 10 40 110 110 110 130 400 Process objects (PO) 50 283 890 890 890 995 3.145 Typical mixed quantity frameworks for SIMATIC PCS 7 S7-400 automation systems Note: The values quoted here are not AS-specific maximum values for the particular item but represent a typical distribution of the available total capacity of the AS during mixed operation of all the items of an assembled block. Comparison of main memory and processing time of the S7-400 automation systems AS type Integrated main memory in MB Processing time in ns AS 414-3/414-3IE 2,8 45 AS 416-2 5,6 30 AS 416-3/416-3IE 11,2 30 30 18 AS 412H/F/FH 0,768 75 AS 414H/F/FH 2,8 45 AS 417H/F/FH 30 18 AS 417-4 10 Siemens ST PCS 7 · Update November 2008 10/3 © Siemens AG 2008 Automation systems Microbox automation system ■ Overview ■ Design Cooling slots 24 V DC power supply 4 x USB 2.0 2 x Gigabit Ethernet DVI-I connection (DVI/VGA combined) PROFIBUS 12 Mbit/s COM1 All-metal enclosure SIMATIC PCS 7 AS RTX With consideration of the scalable automation performance, the SIMATIC PCS 7 AS RTX Microbox automation system represents the starter system in the bottom performance range of SIMATIC PCS 7. The compact and rugged design as well as the complete absence of fans and rotating storage media mean that it resistant to vibration and shock, and make it highly suitable for maintenance-free 24-hour continuous operation at ambient temperatures up to 55 °C. Particularly with small applications, it is an exceptionally good alternative to standard automation systems of S7-400 design. ■ Application 10 As a result of its exceptional physical properties and small dimensions, the SIMATIC PCS 7 AS RTX Microbox automation system is exceptionally suitable for industrial use at plant level. Just like the runtime systems (AS plus OS) and complete systems (AS plus OS and ES) based on SIMATIC PCS 7 BOX, it can be used for: • Small production applications • Package units • Laboratory automation Displays: Power Watchdog Interface inscriptions Design of the SIMATIC PCS 7 AS RTX The SIMATIC PCS 7 AS RTX Microbox automation system is based on a SIMATIC Microbox PC 427B with a system-specific configuration. The following are preinstalled on the supplied 2-GB CompactFlash card: • Windows XP Embedded operating system • WinAC RTX controller software • SIMATIC PC DiagMonitor diagnostics software SIMATIC PCS 7 AS RTX can also be combined with SIMATIC PCS 7 BOX or automation systems of S7-400 design within a plant. Microbox automation system with CompactFlash card The SIMATIC PCS 7 AS RTX has an integral power supply with electrical isolation and mains buffering. Process data can be safely saved by a buffered 2-MB SRAM. Parameterizable monitoring functions (program execution/ watchdog, processor and board temperatures) as well as enhanced diagnostics/messages (e.g. operating hours counter, hard disk/system status) can be recorded via SIMATIC PC DiagMonitor and the maintenance station (PCS 7 asset management), and evaluated or signaled by LED (power/watchdog). 10/4 Siemens ST PCS 7 · Update November 2008 © Siemens AG 2008 Automation systems Microbox automation system Two Ethernet interfaces 10/100/1000 Mbit/s (RJ45) are integrated in the SIMATIC PCS 7 AS RTX for plant bus communication with SIMATIC PCS 7 subsystems such as operator system, engineering system or maintenance station. ET 200M, ET 200ISP and ET 200S I/O stations can be linked over a PROFIBUS DP interface to a comprehensive range of lowcost signal/function modules as well as intelligent field/process devices on the PROFIBUS PA. The SIMATIC PCS 7 AS RTX is configured using the central engineering system of the SIMATIC PCS 7 process control system. The engineering system also administers the AS Runtime licenses of the SIMATIC PCS 7 AS RTX. The scope of delivery of the SIMATIC PCS 7 AS RTX already includes an AS Runtime license for 250 POs. This can be expanded by further AS Runtime licenses for 100 POs. The process objects of additional AS Runtime licenses are then added to process objects which already exist. ■ Technical specifications SIMATIC PCS 7 AS RTX ■ Technical specifications Interfaces • PROFIBUS/MPI 12 Mbit/s (electrically isolated, CP 5611-compatible), 9-contact Sub-D socket • Ethernet 2 x 10/100/1000 Mbit/s (RJ 45), two independent controllers • USB 4 x USB 2.0/high-speed • Serial 1 x COM1 (V.24), 9-contact Sub-D connector • Parallel - • Graphics connection 1 x DVI-I (DVI/VGA combined): • DVI: digital • VGA analog • Keyboard/mouse Connectable via USB (not included in scope of delivery) LED displays • Power • Watchdog Operating system / basic software Design and equipment features Design DIN rail or wall mounting; horizontal (preferred) or vertical Degree of protection to EN 60529 (front/rear) IP20 CPU Operating system Windows XP Embedded preinstalled on CompactFlash card (CF card) 2 GB, no activation required System-tested SIMATIC industrial software WinAC RTX DiagMonitor • Processor Intel Pentium M 1.4 GHz Monitoring/diagnostics functions • Front Side Bus 400 MHz Watchdog • Second Level Cache 2 MB Chipset Intel Alviso 910GML Main memory 1 GB DDR2-SDRAM (SO-DIMM modules) • Monitoring of program execution • Restart can be parameterized following faults • Monitoring time adjustable in the software Temperature • Processor • Motherboard (via SIMATIC PC DiagMonitor and SIMATIC PCS 7 Asset Management) Operating hours counter (via SIMATIC PC DiagMonitor and SIMATIC PCS 7 Asset Management) Graphics • Graphics controller Intel 2D/3D GMA900, integrated in chipset • Graphics memory Dynamic video memory 8 to 128 MB • Resolutions/colors/frequencies - CRT Up to 1600 x 1200 / 32 bit colors / 60 to 120 Hz - DVI Up to 1600 x 1200 / 32 bit colors Drives • Flash drive For CompactFlash card, 2 GB • CD-ROM / DVD-RW / diskette Connectable via USB (not included in scope of delivery) Safety Protection class Protection class I compliant with IEC 61140 Safety directives EN 60950-1; UL 60950; CAN/CSA-C22.2 No. 60950-1; UL 508; CAN/CSA-C22.2 No. 142 or CAN/CSA-C22.2 No. 14-05 Noise level Operation < 40 dB (A) to DIN 45635-1 Siemens ST PCS 7 · Update November 2008 10/5 10 © Siemens AG 2008 Automation systems Microbox automation system ■ Technical specifications ■ Technical specifications Electromagnetic compatibility (EMC) Approvals Emitted interference EN 55022 Class B; FCC Class A CE living accommodation Immunity to conducted interference on the supply lines ± 2 kV (to IEC 61000-4-4; burst) ± 1 kV (to IEC 61000-4-5; symmetrical surge) ± 2 kV (to IEC 61000-4-5; asymmetrical surge) • Emitted interference EN 61000-6-3: 2001 • Noise immunity EN 61000-6-1: 2001 • Emitted interference EN 61000-6-4: 2001 Immunity to interference on signal lines ± 1 kV (to IEC 61000-4-4; burst; length < 3 m) ± 2 kV (to IEC 61000-4-4; burst; length > 3 m) ± 2 kV (to IEC 61000-4-5; surge; length > 30 m) • Noise immunity EN 61000-6-2: 2005 cULus UL 60950-1, Report E11 5352 and CAN/CSA-C22.2 No. 60950-1; UL 508 and CAN/CSA-C22.2 No. 142; CAN/CSA-C22.2 No. 14-05 Immunity to static discharge ± 6 kV contact discharge (to IEC 61000-4-2) ± 8 kV air discharge (to IEC 61000-4-2) Power supply (electrically isolated) Immunity to high-frequency irradiation Immunity to magnetic fields 10 V/m, 80 to 1000 MHz and 1.4 to 2 GHz, 80 % AM (to IEC 61000-4-3) 1 V/m, 2 to 2.7 GHz, 80 % AM (to IEC 61000-4-3) 10 V, 10 kHz to 80 MHz, 80 % AM (to IEC 61000-4-6) 100 A/m, 50/60 Hz (to IEC 61000-4-8) Climatic conditions Tested according to IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-14 Temperature • Operation Horizontal mounting: • 0 to +50 °C • 0 to +55 °C (reduced performance) Vertical mounting: • 0 to +45 °C • Storage/transport -20 to +60 °C • Gradient Operation: max. 10 °C/h; storage: 20 °C/h, no condensation Relative humidity Tested according to IEC 60068-2-78, IEC 60068-2-30 • Operation 5 to 80 % at 25 °C (no condensation) • Storage/transport 5 to 95 % at 25 °C (no condensation) 10 Mechanical environmental conditions Vibrations Tested according to IEC 60068-2-6 • Operation 10 to 58 Hz: 0.075 mm, 58 to 500 Hz: 9.8 m/s² • Storage/transport 5 to 9 Hz: 3.5 mm, 9 to 500 Hz: 9.8 m/s² Shock Tested according to IEC 60068-2-27, IEC 60068-2-29 • Operation 150 m/s², 11 ms • Storage/transport 250 m/s², 6 ms 10/6 Siemens ST PCS 7 · Update November 2008 CE industrial environment Power supply 24 V DC (20.4 to 28.8 V) Short-term voltage dip Max. 10 ms at 0.85 nominal supply voltage (max. 10 events per hour; recovery time min. 1 s) Max. current consumption (at 24 V DC) 2.5 A Power failure signaling Power Fail signal Dimensions and weights Dimensions (W x H x D) in mm 262 x 133 x 47 Weight Approx. 2 kg ■ Selection and Ordering Data SIMATIC PCS 7 AS RTX Assembled and preinstalled automation system on the basis of the SIMATIC Microbox PC 427B with Windows XP Embedded operating system, WinAC RTX controller software and SIMATIC PC DiagMonitor diagnostics software on 2-GB CompactFlash card SIMATIC PCS 7 AS Runtime license V7.0 for 250 POs Order No. 6ES7 654-0UC11-0XX0 Additional and expansion components SIMATIC PCS 7 AS Runtime license (can be added to existing licenses) 7 languages (German, English, French, Italian, Spanish, Chinese, Japanese), executes with Windows XP Professional, single license for 1 installation Type of delivery: License key disk, certificate of license, terms and conditions • 100 POs 6ES7 653-2BA00-0XB5 Individual components (included in scope of delivery of SIMATIC PCS 7 AS RTX) SIMATIC PC CompactFlash card • 2 GB 6ES7 648-2BF01-0XF0 B) Subject to export regulations: AL: N, ECCN: EAR99H B) © Siemens AG 2008 Automation systems Standard automation systems ■ Overview ■ Design The standard automation systems for SIMATIC PCS 7 are available as preassembled and tested all-in-one systems (AS bundles) at no extra charge. Depending on the type of automation system, the RAM of these AS bundles varies as follows: AS type Main memory AS 414-3 / 414-3IE 2.8 MB (1.4 MB each for program and data) AS 416-2 5.6 MB (2.8 MB each for program and data) AS 416-3 / 416-3IE 11.2 MB (5.6 MB each for program and data) AS 417-4 30 MB (15 MB each for program and data) The firmware of the standard automation systems listed in this catalog can be updated in two ways: • Per Flash-EPROM memory card (8 MB) • From the central engineering system via the Industrial Ethernet plant bus The AS 414-3 / 414-3IE, AS 416-2, AS 416-3 / 416-3IE and AS 417-4 standard automation systems are extremely robust, and feature high processing and communications performances. ■ Application The AS 414-3 / 414-3IE automation systems are tailored for small applications with small quantity frameworks. They therefore fulfill the requirements for a low-cost starter solution with a modular and scalable system based on the S7-400 controller range. Larger quantity frameworks can be implemented using the AS 416-2, AS 416-3 / 416-3IE and AS 417-4 automation systems. These systems are preferred for medium-sized systems and bigger. Automation systems with integral Industrial Ethernet interface In addition to the AS 414-3 and AS 416-3 systems with Industrial Ethernet connection via CP 443-1, two automation systems are now offered where the Industrial Ethernet interface is integrated in the CPU. These AS 414-3IE and AS 416-3IE systems are a little cheaper than the comparable AS 414-3 and AS 416-3 systems with the same performance, but differ in their time synchronization (NTP instead of S7). When using the AS 414-3IE and AS 416-3IE systems, there are therefore two separate time synchronization circuits within the SIMATIC PCS 7 system. This results in two alternatives for users: • Create two different servers as masters for NTP and S7 time synchronization, and tolerate any time differences which may result • Use a SICLOCK central plant clock as the common time master Runtime licenses The SIMATIC PCS 7 AS Runtime license for 100 POs already integrated in each AS bundle can be expanded by additional Runtime licenses for 100, 1000 or 10000 POs. The process objects of additional Runtime licenses can be added to process objects which already exist. The number and type (e.g. 100 or 1000) of additional Runtime licenses are irrelevant with regard to the implementable quantity framework. The AS Runtime licenses are administered in the engineering system of the SIMATIC PCS 7 process control system (on an engineering station or in the SIMATIC PCS 7 BOX). Individual configuration of AS bundles The equipment of the standard automation systems as well as their Order Nos. can be individually compiled by selecting preconfigured ordering units. System-specific ordering configurations are available for this purpose in the Section "Selection and ordering data". The recommended preferred configurations are additionally listed with their complete Order Nos. As an alternative to the ordering data in this catalog, the configurator offered in the catalog & online ordering system "A&D Mall" (www.siemens.com/automation/mall) can also be used to select and order the standard automation systems for SIMATIC PCS 7. Siemens ST PCS 7 · Update November 2008 10/7 10 © Siemens AG 2008 Automation systems Standard automation systems Selection and Ordering Data Order No. Selection and Ordering Data AS 414-3 6ES7 654with SIMATIC PCS 7 AS Runtime license for 7 7 7 7 7 - 7 7 B7 100 POs CPU with 3 interfaces (MPI/DP, DP and slot for IF module) 2.8 MB RAM (1.4 MB each for program and data) AS 416-2 with SIMATIC PCS 7 AS Runtime license for 100 POs CPU with 2 interfaces (MPI/DP and DP) 5.6 MB RAM (2.8 MB each for program and data) Type of delivery Type of delivery • Preassembled and tested • Preassembled and tested 8 Memory card 6ES7 6547 7 7 7 7 - 7 7 B7 8 Memory card • Memory card 2 MB RAM (up to approx. 180 POs) B • Memory card 4 MB RAM (up to approx. 300 POs) C • Memory card 4 MB RAM (up to approx. 300 POs) C • Memory card 8 MB RAM (up to approx. 800 POs) D CPU type CPU type • CPU 414-3 (up to approx. 250 POs) • CPU 416-2 (up to approx. 800 POs) C Additive IF 964-DP interface module G Additive IF 964-DP interface module • Without additive IF 964-DP 0 • 1 x IF 964-DP 1 • Without additive IF 964-DP Interface module to Industrial Ethernet plant bus • 1 x CP 443-1 0 Interface module to Industrial Ethernet plant bus • 1 x CP 443-1 1 Rack 1 Rack • UR2 (9 slots), aluminum 3 • UR2 (9 slots), aluminum 3 • UR2 (9 slots), steel 4 • UR2 (9 slots), steel 4 • UR1 (18 slots), aluminum 5 • UR1 (18 slots), aluminum 5 • UR1 (18 slots), steel 6 • UR1 (18 slots), steel 6 Power supply (without backup batteries) 10 Order No. Power supply (without backup batteries) • 1 x PS 407, 10 A for 120/230 V AC/DC B • 1 x PS 407, 10 A for 120/230 V AC/DC B • 1 x PS 407, 10 A for 120/230 V AC/DC, redundancy possible C • 1 x PS 407, 10 A for 120/230 V AC/DC, redundancy possible C • 1 x PS 407, 20 A for 120/230 V AC/DC D • 1 x PS 407, 20 A for 120/230 V AC/DC D • 2 x PS 407, 10 A for 120/230 V AC/DC, redundancy possible E • 2 x PS 407, 10 A for 120/230 V AC/DC, redundancy possible E • 1 x PS 405, 10 A for 24 V DC G • 1 x PS 405, 10 A for 24 V DC G • 1 x PS 405, 10 A for 24 V DC, redundancy possible H • 1 x PS 405, 10 A for 24 V DC, redundancy possible H • 1 x PS 405, 20 A for 24 V DC J • 1 x PS 405, 20 A for 24 V DC J • 2 x PS 405, 10 A for 24 V DC, redundancy possible K • 2 x PS 405, 10 A for 24 V DC, redundancy possible K Additive PROFIBUS DP interface modules1) Additive PROFIBUS DP interface modules1) • Without CP 443-5 Extended 0 • Without CP 443-5 Extended 0 • 1 x CP 443-5 Extended 1 • 1 x CP 443-5 Extended 1 • 2 x CP 443-5 Extended 2 • 2 x CP 443-5 Extended 2 • 3 x CP 443-5 Extended1) 3 • 3 x CP 443-5 Extended 3 • 4 x CP 443-5 Extended1) 4 • 4 x CP 443-5 Extended1) 4 1) With the UR2 rack in combination with a redundant power supply, the number of additive CP 443-5 Extended is limited to 2 10/8 Siemens ST PCS 7 · Update November 2008 1) With the UR2 rack in combination with a redundant power supply, the number of additive CP 443-5 Extended is limited to 3 © Siemens AG 2008 Automation systems Standard automation systems Selection and Ordering Data Order No. Selection and Ordering Data AS 416-3 6ES7 654with SIMATIC PCS 7 AS Runtime license for 7 7 7 7 7 - 7 7 B7 100 POs CPU with 3 interfaces (MPI/DP, DP and slot for IF module) 11.2 MB RAM (5.6 MB each for program and data) AS 417-4 with SIMATIC PCS 7 AS Runtime license for 100 POs CPU with 4 interfaces (MPI/DP, DP and 2 slots for IF modules) 30 MB RAM (15 MB each for program and data) Type of delivery Type of delivery • Preassembled and tested • Preassembled and tested 8 Memory card Order No. 6ES7 6547 7 7 7 7 - 7 7 B7 8 Memory card • Memory card 4 MB RAM (up to approx. 300 POs) C • Memory card 4 MB RAM (up to approx. 300 POs) C • Memory card 8 MB RAM (up to approx. 800 POs) D • Memory card 8 MB RAM (up to approx. 800 POs) D • Memory card 16 MB RAM (up to approx. 3,000 POs) E • Memory card 16 MB RAM (up to approx. 3,000 POs) E CPU type • CPU 416-3 (up to approx. 900 POs) CPU type • CPU 417-4 (up to approx. 3,000 POs) H Additive IF 964-DP interface module K Additive IF 964-DP interface module • Without additive IF 964-DP 0 • Without additive IF 964-DP 0 • 1 x IF 964-DP 1 • 1 x IF 964-DP 1 • 2 x IF 964-DP 2 Interface module to Industrial Ethernet plant bus • 1 x CP 443-1 Interface module to Industrial Ethernet plant bus • 1 x CP 443-1 1 Rack 1 Rack • UR2 (9 slots), aluminum 3 • UR2 (9 slots), aluminum 3 • UR2 (9 slots), steel 4 • UR2 (9 slots), steel 4 • UR1 (18 slots), aluminum 5 • UR1 (18 slots), aluminum 5 • UR1 (18 slots), steel 6 • UR1 (18 slots), steel 6 Power supply (without backup batteries) 10 Power supply (without backup batteries) • 1 x PS 407, 10 A for 120/230 V AC/DC B • 1 x PS 407, 10 A for 120/230 V AC/DC B • 1 x PS 407, 10 A for 120/230 V AC/DC, redundancy possible C • 1 x PS 407, 10 A for 120/230 V AC/DC, redundancy possible C • 1 x PS 407, 20 A for 120/230 V AC/DC D • 1 x PS 407, 20 A for 120/230 V AC/DC D • 2 x PS 407, 10 A for 120/230 V AC/DC, redundancy possible E • 2 x PS 407, 10 A for 120/230 V AC/DC, redundancy possible E • 1 x PS 405, 10 A for 24 V DC G • 1 x PS 405, 10 A for 24 V DC G • 1 x PS 405, 10 A for 24 V DC, redundancy possible H • 1 x PS 405, 10 A for 24 V DC, redundancy possible H • 1 x PS 405, 20 A for 24 V DC J • 1 x PS 405, 20 A for 24 V DC J • 2 x PS 405, 10 A for 24 V DC, redundancy possible K • 2 x PS 405, 10 A for 24 V DC, redundancy possible K Additive PROFIBUS DP interface modules1) Additive PROFIBUS DP interface modules1) • Without CP 443-5 Extended 0 • Without CP 443-5 Extended 0 • 1 x CP 443-5 Extended 1 • 1 x CP 443-5 Extended 1 • 2 x CP 443-5 Extended 2 • 2 x CP 443-5 Extended 2 • 3 x CP 443-5 Extended1) 3 • 3 x CP 443-5 Extended1) 3 • 4 x CP 443-5 Extended1) 4 • 4 x CP 443-5 Extended1) 4 1) With the UR2 rack in combination with a redundant power supply, the number of additive CP 443-5 Extended is limited to 2 1) With the UR2 rack in combination with a redundant power supply, the number of additive CP 443-5 Extended is limited to 2 Siemens ST PCS 7 · Update November 2008 10/9 © Siemens AG 2008 Automation systems Standard automation systems Selection and Ordering Data Order No. Selection and Ordering Data AS 414-3IE with SIMATIC PCS 7 AS Runtime license for 100 POs CPU with 2 DP interfaces (MPI/DP and slot for IF module) 2.8 MB RAM (1.4 MB each for program and data) 6ES7 654- AS 416-3IE with SIMATIC PCS 7 AS Runtime license for 100 POs CPU with 2 DP interfaces (MPI/DP and slot for IF module) 11.2 MB RAM (5.6 MB each for program and data) 7 7 7 7 7 - 7 7 B7 Type of delivery • Preassembled and tested 6ES7 6547 7 7 7 7 - 7 7 B7 Type of delivery • Preassembled and tested 8 Memory card 8 Memory card • Memory card 2 MB RAM (up to approx. 180 POs) B • Memory card 4 MB RAM (up to approx. 300 POs) C • Memory card 4 MB RAM (up to approx. 300 POs) C • Memory card 8 MB RAM (up to approx. 800 POs) D • Memory card 16 MB RAM (up to approx. 3,000 POs) E CPU type CPU type • CPU 414-3 PN/DP (up to approx. 250 POs) • CPU 416-3 PN/DP (up to approx. 900 POs) D Additive IF 964-DP interface module J Additive IF 964-DP interface module • Without additive IF 964-DP 0 • Without additive IF 964-DP 0 • 1 x IF 964-DP 1 • 1 x IF 964-DP 1 Interface module to Industrial Ethernet plant bus • Integrated, without CP 443-1 Interface module to Industrial Ethernet plant bus • Integrated, without CP 443-1 0 Rack 0 Rack • UR2 (9 slots), aluminum 3 • UR2 (9 slots), aluminum 3 • UR2 (9 slots), steel 4 • UR2 (9 slots), steel 4 • UR1 (18 slots), aluminum 5 • UR1 (18 slots), aluminum 5 • UR1 (18 slots), steel 6 • UR1 (18 slots), steel 6 Power supply (without backup batteries) 10 Order No. Power supply (without backup batteries) • 1 x PS 407, 10 A for 120/230 V AC/DC B • 1 x PS 407, 10 A for 120/230 V AC/DC B • 1 x PS 407, 10 A for 120/230 V AC/DC, redundancy possible C • 1 x PS 407, 10 A for 120/230 V AC/DC, redundancy possible C • 1 x PS 407, 20 A for 120/230 V AC/DC D • 1 x PS 407, 20 A for 120/230 V AC/DC D • 2 x PS 407, 10 A for 120/230 V AC/DC, redundancy possible E • 2 x PS 407, 10 A for 120/230 V AC/DC, redundancy possible E • 1 x PS 405, 10 A for 24 V DC G • 1 x PS 405, 10 A for 24 V DC G • 1 x PS 405, 10 A for 24 V DC, redundancy possible H • 1 x PS 405, 10 A for 24 V DC, redundancy possible H • 1 x PS 405, 20 A for 24 V DC J • 1 x PS 405, 20 A for 24 V DC J • 2 x PS 405, 10 A for 24 V DC, redundancy possible K • 2 x PS 405, 10 A for 24 V DC, redundancy possible K Additive PROFIBUS DP interface modules1) Additive PROFIBUS DP interface modules1) • Without CP 443-5 Extended 0 • Without CP 443-5 Extended 0 • 1 x CP 443-5 Extended 1 • 1 x CP 443-5 Extended 1 • 2 x CP 443-5 Extended 2 • 2 x CP 443-5 Extended 2 • 3 x CP 443-5 Extended 3 • 3 x CP 443-5 Extended 3 • 4 x CP 443-5 Extended1) 4 • 4 x CP 443-5 Extended1) 4 1) With the UR2 rack in combination with a redundant power supply, the number of additive CP 443-5 Extended is limited to 3 10/10 Siemens ST PCS 7 · Update November 2008 1) With the UR2 rack in combination with a redundant power supply, the number of additive CP 443-5 Extended is limited to 3 © Siemens AG 2008 Automation systems Standard automation systems Recommended preferred types ■ Selection and Ordering Data ■ Selection and Ordering Data Order No. SIMATIC PCS 7 standard automation systems with Industrial Ethernet interfacing via CP, recommended preferred types AS 414-3 automation system with SIMATIC PCS 7 AS Runtime license for 100 POs Preassembled and tested, without additive IF 964-DP and without CP 443-5 Extended, comprising: CPU 414-3 with 3 interfaces (MPI/DP, DP and slot for IF module), 2.8 MB RAM (1.4 MB each for program and data), CP 443-1 communications processor for connection to Industrial Ethernet plant bus as well as Order No. AS 416-2 automation system with SIMATIC PCS 7 AS Runtime license for 100 POs Preassembled and tested, without additive IF 964-DP and without CP 443-5 Extended, comprising: CPU 416-2 with 2 interfaces (MPI/DP and DP), 5.6 MB RAM (2.8 MB each for program and data), CP 443-1 communications processor for connection to Industrial Ethernet plant bus as well as • Aluminum UR1 rack (18 slots): 6ES7 654-8CG01-5DB0 B) B) - PS 407 power supply; 20 A for 120/230 V AC/DC, without backup batteries, memory card 4 MB RAM 6ES7 654-8DG01-5DB0 B) B) - PS 407 power supply; 20 A for 120/230 V AC/DC, without backup batteries, memory card 8 MB RAM 6ES7 654-8CG01-5JB0 B) B) - PS 405 power supply; 20 A for 24 V DC, without backup batteries, memory card 4 MB RAM 6ES7 654-8DG01-5JB0 B) B) - PS 405 power supply; 20 A for 24 V DC, without backup batteries, memory card 8 MB RAM 6ES7 654-8CG01-3BB0 B) B) - PS 407 power supply; 10 A for 120/230 V AC/DC, without backup batteries, memory card 4 MB RAM 6ES7 654-8DG01-3BB0 B) B) - PS 407 power supply; 10 A for 120/230 V AC/DC, without backup batteries, memory card 8 MB RAM 6ES7 654-8CG01-3GB0 B) B) - PS 405 power supply; 10 A for 24 V DC, without backup batteries, memory card 4 MB RAM 6ES7 654-8DG01-3GB0 B) B) - PS 405 power supply; 10 A for 24 V DC, without backup batteries, memory card 8 MB RAM • Aluminum UR1 rack (18 slots): - PS 407 power supply; 20 A for 120/230 V AC/DC, without backup batteries, memory card 2 MB RAM 6ES7 654-8BC01-5DB0 - PS 407 power supply; 20 A for 120/230 V AC/DC, without backup batteries, memory card 4 MB RAM 6ES7 654-8CC01-5DB0 - PS 405 power supply; 20 A for 24 V DC, without backup batteries, memory card 2 MB RAM 6ES7 654-8BC01-5JB0 - PS 405 power supply; 20 A for 24 V DC, without backup batteries, memory card 4 MB RAM 6ES7 654-8CC01-5JB0 • Aluminum UR2 rack (9 slots): • Aluminum UR2 rack (9 slots): - PS 407 power supply; 10 A for 120/230 V AC/DC, without backup batteries, memory card 2 MB RAM 6ES7 654-8BC01-3BB0 - PS 407 power supply; 10 A for 120/230 V AC/DC, without backup batteries, memory card 4 MB RAM 6ES7 654-8CC01-3BB0 - PS 405 power supply; 10 A for 24 V DC, without backup batteries, memory card 2 MB RAM 6ES7 654-8BC01-3GB0 - PS 405 power supply; 10 A for 24 V DC, without backup batteries, memory card 4 MB RAM 6ES7 654-8CC01-3GB0 B) Subject to export regulations: AL: N, ECCN: EAR99H Siemens ST PCS 7 · Update November 2008 10/11 10 © Siemens AG 2008 Automation systems Standard automation systems ■ Selection and Ordering Data ■ Selection and Ordering Data Order No. AS 416-3 automation system with SIMATIC PCS 7 AS Runtime license for 100 POs Preassembled and tested, without additive IF 964-DP and without CP 443-5 Extended, comprising: CPU 416-3 with 3 interfaces (MPI/DP, DP and slot for IF module), 11.2 MB RAM (5.6 MB each for program and data), CP 443-1 communications processor for connection to Industrial Ethernet plant bus as well as • Aluminum UR1 rack (18 slots): • Aluminum UR1 rack (18 slots): - PS 407 power supply; 20 A for 120/230 V AC/DC, without backup batteries, memory card 8 MB RAM 6ES7 654-8DH01-5DB0 B) - PS 407 power supply; 20 A for 120/230 V AC/DC, without backup batteries, memory card 4 MB RAM 6ES7 654-8CK01-5DB0 B) - PS 407 power supply; 20 A for 120/230 V AC/DC, without backup batteries, memory card 16 MB RAM 6ES7 654-8EH01-5DB0 B) - PS 407 power supply; 20 A for 120/230 V AC/DC, without backup batteries, memory card 16 MB RAM 6ES7 654-8EK01-5DB0 B) - PS 405 power supply; 20 A for 24 V DC, without backup batteries, memory card 8 MB RAM 6ES7 654-8DH01-5JB0 B) - PS 405 power supply; 20 A for 24 V DC, without backup batteries, memory card 4 MB RAM 6ES7 654-8CK01-5JB0 B) - PS 405 power supply; 20 A for 24 V DC, without backup batteries, memory card 16 MB RAM 6ES7 654-8EH01-5JB0 B) - PS 405 power supply; 20 A for 24 V DC, without backup batteries, memory card 16 MB RAM 6ES7 654-8EK01-5JB0 B) - PS 407 power supply; 10 A for 120/230 V AC/DC, without backup batteries, memory card 8 MB RAM 6ES7 654-8DH01-3BB0 B) - PS 407 power supply; 10 A for 120/230 V AC/DC, without backup batteries, memory card 4 MB RAM 6ES7 654-8CK01-3BB0 B) - PS 407 power supply; 10 A for 120/230 V AC/DC, without backup batteries, memory card 16 MB RAM 6ES7 654-8EH01-3BB0 B) - PS 407 power supply; 10 A for 120/230 V AC/DC, without backup batteries, memory card 16 MB RAM 6ES7 654-8EK01-3BB0 B) - PS 405 power supply; 10 A for 24 V DC, without backup batteries, memory card 8 MB RAM 6ES7 654-8DH01-3GB0 B) - PS 405 power supply; 10 A for 24 V DC, without backup batteries, memory card 4 MB RAM 6ES7 654-8CK01-3GB0 B) - PS 405 power supply; 10 A for 24 V DC, without backup batteries, memory card 16 MB RAM 6ES7 654-8EH01-3GB0 B) - PS 405 power supply; 10 A for 24 V DC, without backup batteries, memory card 16 MB RAM 6ES7 654-8EK01-3GB0 B) • Aluminum UR2 rack (9 slots): 10 Order No. AS 417-4 automation system with SIMATIC PCS 7 AS Runtime license for 100 POs Preassembled and tested, without additive IF 964-DP and without CP 443-5 Extended, comprising: CPU 417-4 with 4 interfaces (MPI/DP, DP and 2 slots for IF modules), 30 MB RAM (15 MB each for program and data), CP 443-1 communications processor for connection to Industrial Ethernet plant bus as well as • Aluminum UR2 rack (9 slots): B) Subject to export regulations: AL: N, ECCN: EAR99H 10/12 Siemens ST PCS 7 · Update November 2008 © Siemens AG 2008 Automation systems Standard automation systems ■ Selection and Ordering Data ■ Selection and Ordering Data Order No. Order No. SIMATIC PCS 7 standard automation systems with integral Industrial Ethernet interface module, recommended preferred types Runtime licenses for SIMATIC PCS 7 automation systems (can be added to existing licenses) AS 414-3IE automation system with SIMATIC PCS 7 AS Runtime license for 100 POs Preassembled and tested, without CP 4435 Extended, comprising: CPU 414-3 PN/DP with 2 DP interfaces (MPI/DP and preassembled IF 964-DP module), 2.8 MB RAM (1.4 MB each for program and data), as well as SIMATIC PCS 7 AS Runtime license 6 languages (German, English, French, Italian, Spanish, Chinese), executes in the engineering system with Windows XP Professional, floating license for 1 installation Type of delivery: License key disk, certificate of license, terms and conditions • Aluminum UR2 rack (9 slots): - PS 407 power supply; 10 A for 120/230 V AC/DC, without backup batteries, memory card 2 MB RAM 6ES7 654-8BD10-3BB0 B) - PS 407 power supply; 10 A for 120/230 V AC/DC, without backup batteries, memory card 4 MB RAM 6ES7 654-8CD10-3BB0 - PS 405 power supply; 10 A for 24 V DC, without backup batteries, memory card 2 MB RAM 6ES7 654-8BD10-3GB0 B) - PS 405 power supply; 10 A for 24 V DC, without backup batteries, memory card 4 MB RAM 6ES7 654-8CD10-3GB0 B) • 100 POs 6ES7 653-2BA00-0XB5 • 1,000 POs 6ES7 653-2BB00-0XB5 • 10,000 POs 6ES7 653-2BC00-0XB5 B) Individual components AS 416-3IE automation system with Runtime license for 100 POs Preassembled and tested, without CP 443-5 Extended, comprising: CPU 416-3 PN/DP with 2 DP interfaces (MPI/DP and preassembled IF 964-DP module), 11.2 MB RAM (5.6 MB each for program and data), as well as • Aluminum UR2 rack (9 slots): ■ Selection and Ordering Data Order No. Individual components for standard SIMATIC PCS 7 automation systems CPU 414-3 RAM 2.8 MB (1.4 MB each for program and data); module occupies 2 slots 6ES7 414-3XM05-0AB0 B) CPU 416-2 RAM 5.6 MB (2.8 MB each for program and data); module occupies 1 slot 6ES7 416-2XN05-0AB0 B) CPU 416-3 RAM 11.2 MB (5.6 MB each for program and data); module occupies 2 slots 6ES7 416-3XR05-0AB0 B) CPU 417-4 RAM 30 MB (15 MB each for program and data); module occupies 2 slots 6ES7 417-4XT05-0AB0 10 - PS 407 power supply; 10 A for 120/230 V AC/DC, without backup batteries, memory card 4 MB RAM 6ES7 654-8CJ10-3BB0 B) CPU 414-3 PN/DP RAM 2.8 MB (1.4 MB each for program and data); module occupies 2 slots 6ES7 414-3EM05-0AB0 B) - PS 407 power supply; 10 A for 120/230 V AC/DC, without backup batteries, memory card 16 MB RAM 6ES7 654-8EJ10-3BB0 B) CPU 416-3 PN/DP RAM 11.2 MB (5.6 MB each for program and data); module occupies 2 slots 6ES7 416-3ER05-0AB0 B) - PS 405 power supply; 10 A for 24 V DC, without backup batteries, memory card 4 MB RAM 6ES7 654-8CJ10-3GB0 B) - PS 405 power supply; 10 A for 24 V DC, without backup batteries, memory card 16 MB RAM 6ES7 654-8EJ10-3GB0 B) Memory card RAM • 2 MB 6ES7 952-1AL00-0AA0 • 4 MB 6ES7 952-1AM00-0AA0 • 8 MB 6ES7 952-1AP00-0AA0 • 16 MB 6ES7 952-1AS00-0AA0 • 64 MB 6ES7 952-1AY00-0AA0 Memory Card Flash-EPROM Only required to update firmware • 8 MB 6ES7 952-1KP00-0AA0 B) Subject to export regulations: AL: N, ECCN: EAR99H Siemens ST PCS 7 · Update November 2008 10/13 © Siemens AG 2008 Automation systems Standard automation systems ■ Selection and Ordering Data 10 Order No. CP 443-1 Communications processor for connection of SIMATIC S7-400 to Industrial Ethernet through TCP/IP, ISO and UDP; for S7 communication, S5-compatible communication (SEND/RECEIVE) with FETCH/WRITE with or without RFC 1006, diagnostics expansion, Multicast, commissioning through LAN 10/100 Mbit/s, with electronic manual on CD-ROM 6GK7 443-1EX11-0XE0 CP 443-5 Extended Communications processor for connection of SIMATIC S7-400 to PROFIBUS as DP master or for S7 communication, for increasing the number of DP lines, for data set routing with SIMATIC PDM and for 10-ms time stamp, electronic manual on CD; module occupies 1 slot 6GK7 443-5DX04-0XE0 IF 964-DP Interface module for connection of another PROFIBUS DP line, for plugging into a free DP module slot of the CPU 6ES7 964-2AA04-0AB0 PS 407 power supply module; 4A 120/230 V AC/DC; 5 V DC/4 A, 24 V DC/0.5 A; with battery compartment for 1 backup battery, module occupies 1 slot 6ES7 407-0DA02-0AA0 PS 407 power supply module; 10 A 120/230 V AC/DC; 5 V DC/10 A, 24 V DC/1 A; with battery compartment for 2 backup batteries, module occupies 2 slots 6ES7 407-0KA02-0AA0 PS 407 power supply module; 10 A, redundant design possible 120/230 V AC/DC; 5 V DC/10 A, 24 V DC/1 A; with battery compartment for 2 backup batteries, module occupies 2 slots 6ES7 407-0KR02-0AA0 PS 407 power supply module; 20 A 120/230 V AC/DC; 5 V DC/20 A, 24 V DC/1 A; with battery compartment for 2 backup batteries, module occupies 2 slots 6ES7 407-0RA02-0AA0 PS 405 power supply module; 4A 24 V DC; 5 V DC/4 A, 24 V DC/0.5 A; with battery compartment for 1 backup battery, module occupies 1 slot 6ES7 405-0DA02-0AA0 PS 405 power supply module; 10 A 24 V DC; 5 V DC/10 A, 24 V DC/1 A; with battery compartment for 2 backup batteries, module occupies 2 slots 6ES7 405-0KA02-0AA0 10/14 ■ Selection and Ordering Data Order No. PS 405 power supply module; 10 A, redundant design possible 24 V DC; 5 V DC/10 A, 24 V DC/1 A; with battery compartment for 2 backup batteries, module occupies 2 slots 6ES7 405-0KR02-0AA0 PS 405 power supply module; 20 A 24 V DC; 5 V DC/20 A, 24 V DC/1 A; with battery compartment for 2 backup batteries, module occupies 2 slots 6ES7 405-0RA02-0AA0 Backup battery Type AA, 2.3 Ah 6ES7 971-0BA00 Aluminum UR1 rack 18 slots 6ES7 400-1TA11-0AA0 Aluminum UR2 rack 9 slots 6ES7 400-1JA11-0AA0 Aluminum CR3 rack 4 slots 6ES7 401-1DA01-0AA0 Steel UR1 rack 18 slots 6ES7 400-1TA01-0AA0 Steel UR2 rack 9 slots 6ES7 400-1JA01-0AA0 B) Subject to export regulations: AL: N, ECCN: EAR99H Siemens ST PCS 7 · Update November 2008 B) B) © Siemens AG 2008 Automation systems Fault-tolerant automation systems ■ Overview ■ Design Fault-tolerant automation systems for SIMATIC PCS 7 are available as preassembled and tested all-in-one systems (AS bundles) at no extra charge. Depending on the type of automation system, the RAM of these AS bundles varies as follows: AS type Main memory AS 412H 768 KB (512 KB for program and 256 KB for data) AS 414H 2.8 MB (1.4 MB each for program and data) AS 417H 30 MB (15 MB each for program and data) Runtime licenses Each AS bundle is already provided as standard with the SIMATIC PCS 7 AS Runtime license for 100 process objects (PO). The number of process objects can be extended by additional Runtime licenses for 100, 1000 or 10000 POs. The process objects of additional Runtime licenses can be added to process objects which already exist. The number and type (e.g. 100 or 1000) of additional Runtime licenses are irrelevant. The AS Runtime licenses are administered on a SIMATIC PCS 7 engineering system or in the SIMATIC PCS 7 BOX. Connection of process I/Os Fault-tolerant automation systems are used to reduce the risk of production failures. The higher investment costs for fault-tolerant automation systems are frequently negligible compared to the costs resulting from production failures. The higher the costs of a production failure, the more worthwhile it is to use a fault-tolerant system. Fault-tolerant automation systems can be mounted in a UR2-H compact rack with divided backplane bus or in two separate racks (UR1 or UR2). The design in two racks allows physical separation of the redundant subsystems, e.g. by a fireproof partition. Fault-tolerant automation systems can be used on their own in a plant configuration, or together with standard and safety-related automation systems. Several PROFIBUS DP lines with distributed process I/Os can be operated on each sub-AS through the internal PROFIBUS DP interface or by using additional communications processors. • The ET 200M remote I/O stations are connected via two IM 153-2 High Feature interface modules on a special bus module to two redundant PROFIBUS DP segments. • The intelligent field devices on the PROFIBUS PA are connected over a DP/PA link to two redundant IM 153-2 High Feature interface modules. • Non-redundant PROFIBUS DP devices, e.g. ET 200S distributed I/O devices, can be connected to the redundant PROFIBUS DP over the Y-link. These configurations can also be mixed together. Communication over the plant bus The AS 412H, AS 414H and AS 417H automation systems are connected as standard by one communications processor per sub-AS to the plant bus. The plant bus can be implemented in the form of a ring structure, which can also be configured with redundant architecture if the availability requirements are high. When there are two redundant rings it makes sense to use two communications processors per sub-AS and to distribute their connections between the two rings (4-way connection). Double faults such as failure of the OSM/SCALANCE switch on ring 1 with simultaneous interruption in the bus cable on ring 2 can thus be tolerated. Siemens ST PCS 7 · Update November 2008 10/15 10 © Siemens AG 2008 Automation systems Fault-tolerant automation systems Individual configuration of AS bundles The equipment of the fault-tolerant automation systems as well as their Order Nos. can be individually compiled by selecting preconfigured ordering units. System-specific ordering configurations are available for this purpose in the following Section "Selection and ordering data". These are divided into: • Single stations: AS 412-3-1H, AS 414-4-1H and AS 417-4-1H with only one CPU, e.g. for the following cases: - Subsequent expansion to a redundant system - Redundant configuration on UR1 racks, comprising 2 Single Stations, 4 sync modules and 2 sync fiber-optic cables • Redundant stations: AS 412-3-2H, AS 414-4-2H and AS 417-4-2H with two redundant CPUs, mounted on one common rack (UR2-H) or two separate racks (UR2) In order to rapidly access the recommended preferred configurations, these are additionally listed with their complete Order Numbers. As an alternative to the ordering data in this catalog, the configurator offered in the catalog & online ordering system "A&D Mall" (www.siemens.com/automation/mall) can also be used to select and order fault-tolerant automation systems for SIMATIC PCS 7. Ordering information: For a redundant configuration based on 2 Single Stations, you additionally require 4 sync modules (up to 10 m or 10 km) and 2 fiber-optic sync cables. Their selection depends on the distance between the two Single Stations. The AS 412H (AS 412-3-1H/AS 412-3-2H) automation systems currently only support sync modules with a range up to 10 m. Fiber-optic sync cables longer than 1 m must always be ordered separately (2 of each required). 10 10/16 Siemens ST PCS 7 · Update November 2008 ■ Function The fault-tolerant automation systems of SIMATIC PCS 7 are based on the 1-out-of-2 principle. In the event of a fault, they switch over to the standby system. These systems use a completely redundant design to maximize availability. Therefore all important system components are present twice, such as: • Central processing unit • Power supply • Hardware for linking the two CPUs Which other components are also made available in pairs in the interest of availability depends on the application-specific system architecture. The two subsystems of a redundant automation system are electrically isolated from one another. This increases the system stability with respect to electromagnetic interference. The firmware of the fault-tolerant automation systems can be updated in two ways: • Per Flash-EPROM memory card (8 MB) • From the central engineering system via the Industrial Ethernet plant bus © Siemens AG 2008 Automation systems Fault-tolerant automation systems Order No. Selection and ordering data Order No. Selection and ordering data AS 412-3-1H (Single Station) 6ES7 654with SIMATIC PCS 7 AS Runtime license for 7 7 7 7 7 - 7 7 B7 100 POs CPU with 1 interface (MPI/DP master) 768 KB RAM (512 KB for program and 256 KB for data) AS 414-4-1H (Single Station) with SIMATIC PCS 7 AS Runtime license for 100 POs CPU with 2 interfaces (MPI/DP master and DP master) 2.8 MB RAM (1.4 MB each for program and data) Type of delivery Type of delivery • Preassembled and tested • Preassembled and tested 8 Memory card 6ES7 6547 7 7 7 7 - 7 7 B7 8 Memory card • Memory card 1 MB RAM (up to approx. 50 POs) A • Memory card 2 MB RAM (up to approx. 180 POs) B • Memory card 2 MB RAM (up to approx. 180 POs) B • Memory card 4 MB RAM (up to approx. 300 POs) C CPU type CPU type • CPU 412-3H (up to approx. 50 POs) • CPU 414-4H (up to approx. 250 POs) A Additive IF 964-DP interface module E Additive IF 964-DP interface module • Without additive IF 964-DP • Without additive IF 964-DP 0 Interface module to Industrial Ethernet plant bus1) 0 Interface module to Industrial Ethernet plant bus1) • 1 x CP 443-11) • 1 x CP 443-11) 1 1) • 2 x CP 443-1 for redundant interface module 1 1) • 2 x CP 443-1 for redundant interface module 2 Rack 2 Rack • UR2 (9 slots), aluminum 3 • UR2 (9 slots), aluminum 3 • UR2 (9 slots), steel 4 • UR2 (9 slots), steel 4 • UR1 (18 slots), aluminum 5 • UR1 (18 slots), aluminum 5 • UR1 (18 slots), steel 6 • UR1 (18 slots), steel 6 Power supply (without backup batteries) Power supply (without backup batteries) • 1 x PS 407, 10 A for 120/230 V AC/DC B • 1 x PS 407, 10 A for 120/230 V AC/DC B • 1 x PS 407, 10 A for 120/230 V AC/DC, redundant design possible C • 1 x PS 407, 10 A for 120/230 V AC/DC, redundant design C • 1 x PS 407, 20 A for 120/230 V AC/DC D • 1 x PS 407, 20 A for 120/230 V AC/DC D • 2 x PS 407, 10 A for 120/230 V AC/DC, redundant design possible E • 2 x PS 407, 10 A for 120/230 V AC/DC, redundant design E • 1 x PS 405, 10 A for 24 V DC G • 1 x PS 405, 10 A for 24 V DC G • 1 x PS 405, 10 A for 24 V DC, redundant design possible H • 1 x PS 405, 10 A for 24 V DC, redundant design H • 1 x PS 405, 20 A for 24 V DC J • 1 x PS 405, 20 A for 24 V DC J • 2 x PS 405, 10 A for 24 V DC, redundant design K • 2 x PS 405, 10 A for 24 V DC, redundant design K Additive PROFIBUS DP interface modules1) 10 Additive PROFIBUS DP interface modules1) • Without CP 443-5 Extended 0 • Without CP 443-5 Extended 0 • 1 x CP 443-5 Extended 1 • 1 x CP 443-5 Extended 1 Extended1) • 3 x CP 443-5 Extended1) • 4 x CP 443-5 Extended1) • 2 x CP 443-5 1) Up to 5 CPs can be plugged into the UR2 rack with a single power supply, or up to 3 with a redundant power supply. 2 • 2 x CP 443-5 Extended1) 2 3 • 3 x CP 443-5 Extended1) 3 4 • 4 x CP 443-5 Extended1) 4 1) Up to 5 CPs can be plugged into the UR2 rack with a single power supply, or up to 3 with a redundant power supply. Siemens ST PCS 7 · Update November 2008 10/17 © Siemens AG 2008 Automation systems Fault-tolerant automation systems Selection and ordering data Order No. Selection and ordering data AS 417-4-1H (Single Station) with SIMATIC PCS 7 AS Runtime license for 100 POs CPU with 2 interfaces (MPI/DP master and DP master) 30 MB RAM (15 MB each for program and data) 6ES7 654- AS 412-3-2H (Redundant Station) 6ES7 656with SIMATIC PCS 7 AS Runtime license for 7 7 7 7 7 - 7 7 B7 100 POs 2 x CPU with 1 interface each (MPI/DP master) 2 x 768 KB RAM (512 KB each for program and 256 KB each for data) 7 7 7 7 7 - 7 7 B7 Type of delivery Type of delivery • Preassembled and tested • Preassembled and tested 8 Memory card 8 Memory card • Memory card 4 MB RAM (up to approx. 300 POs) C • 2 x memory card 1 MB RAM (up to approx. 50 POs) A • Memory card 8 MB RAM (up to approx. 800 POs) D • 2 x memory card 2 MB RAM (up to approx. 180 POs) B • Memory card 16 MB RAM (up to approx. 3,000 POs) E CPU type CPU type • 2 x CPU 412-3H (up to approx. 50 POs) • CPU 417-4H (up to approx. 2,500 POs) M A Sync modules and cables Additive IF 964-DP interface module • Without additive IF 964-DP 0 • 1 x IF 964-DP 1 • 2 x 2 sync modules for distances up to 10 m and 2 x FO sync cable, 1 m Interface module to Industrial Ethernet plant bus1) 3 Interface module to Industrial Ethernet plant bus1) • 1 x CP 443-11) 1) • 2 x CP 443-1 for redundant interface module 1 • 2 x CP 443-1 for redundant interface module1) 1 2 • 2 x 2 CP 443-1 for 4-way connection1) 2 Rack 10 Order No. Rack • UR2 (9 slots), aluminum 3 • 1 x UR2-H (2 x 9 slots), aluminum 1 • UR2 (9 slots), steel 4 • 1 x UR2-H (2 x 9 slots), steel 2 • UR1 (18 slots), aluminum 5 • 2 x UR2 (9 slots), aluminum 3 • UR1 (18 slots), steel 6 • 2 x UR2 (9 slots), steel 4 Power supply (without backup batteries) Power supply (without backup batteries) • 1 x PS 407, 10 A for 120/230 V AC/DC B • 2 x PS 407, 10 A for 120/230 V AC/DC B • 1 x PS 407, 10 A for 120/230 V AC/DC, redundant design C • 2 x PS 407, 10 A for 120/230 V AC/DC, redundant design C • 1 x PS 407, 20 A for 120/230 V AC/DC D • 2 x PS 407, 20 A for 120/230 V AC/DC D • 2 x PS 407, 10 A for 120/230 V AC/DC, redundant design E • 2 x 2 PS 407, 10 A for 120/230 V AC/DC, redundant design E • 1 x PS 405, 10 A for 24 V DC G • 2 x PS 405, 10 A for 24 V DC G • 1 x PS 405, 10 A for 24 V DC, redundant design H • 2 x PS 405, 10 A for 24 V DC, redundant design H • 1 x PS 405, 20 A for 24 V DC J • 2 x PS 405, 20 A for 24 V DC J • 2 x PS 405, 10 A for 24 V DC, redundant design K • 2 x PS 405, 10 A for 24 V DC, redundant design K Additive PROFIBUS DP interface modules1) Additive PROFIBUS DP interface modules1) • Without CP 443-5 Extended 0 • Without CP 443-5 Extended 0 • 1 x CP 443-5 Extended 1 • 2 x CP 443-5 Extended 1 • 2 x CP 443-5 Extended1) 2 • 2 x 2 CP 443-5 Extended1) 2 • 3 x CP 443-5 Extended1) 3 • 2 x 3 CP 443-5 Extended1) 3 • 4 x CP 443-5 Extended1) 4 • 2 x 4 CP 443-5 Extended1) 4 1) Up to 5 CPs can be plugged into the UR2 rack with a single power supply, or up to 3 with a redundant power supply. 10/18 Siemens ST PCS 7 · Update November 2008 1) Up to 5 CPs can be plugged in per subsystem with a single power supply, or up to 3 with a redundant power supply. © Siemens AG 2008 Automation systems Fault-tolerant automation systems Selection and ordering data Order No. Selection and ordering data AS 414-4-2H (Redundant Station) 6ES7 656with SIMATIC PCS 7 AS Runtime license for 7 7 7 7 7 - 7 7 B7 100 POs 2 x CPU with 2 interfaces (MPI/DP master and DP master) 2 x 2.8 MB RAM (1.4 MB each for program and data) AS 417-4-2H (Redundant Station) with SIMATIC PCS 7 AS Runtime license for 100 POs 2 x CPU with 2 interfaces (MPI/DP master and DP master) 2 x 30 MB RAM (15 MB each for program and data) Type of delivery Type of delivery • Preassembled and tested • Preassembled and tested 8 Memory card Order No. 6ES7 6567 7 7 7 7 - 7 7 B7 8 Memory card • 2 x memory card 2 MB RAM (up to approx. 180 POs) B • 2 x memory card 4 MB RAM (up to approx. 300 POs) C • 2 x memory card 4 MB RAM (up to approx. 300 POs) C • 2 x memory card 8 MB RAM (up to approx. 800 POs) D • 2 x memory card 16 MB RAM (up to approx. 3,000 POs) E CPU type CPU type • 2 x CPU 414-4H (up to approx. 250 POs) • 2 x CPU 417-4H (up to approx. 2,500 POs) E Sync modules and cables M Sync modules and cables • 2 x 2 sync modules for distances up to 10 m and 2 x FO sync cable, 1 m 3 • 2 x 2 sync modules for distances up to 10 m and 2 x FO sync cable, 1 m 3 • 2 x 2 sync modules for up to 10 km and 2 x FO sync cable, 1 m, for testing 4 • 2 x 2 sync modules for up to 10 km and 2 x FO sync cable, 1 m, for testing 4 Interface module to Industrial Ethernet plant bus1) • 2 x CP 443-1 for redundant interface module1) • 2 x 2 CP 443-1 for 4-way connection1) Interface module to Industrial Ethernet plant bus1) 1 • 2 x CP 443-1 for redundant interface module1) 1 2 • 2 x 2 CP 443-1 for 4-way connection1) 2 Rack Rack • 1 x UR2-H (2 x 9 slots), aluminum 1 • 1 x UR2-H (2 x 9 slots), aluminum 1 • 1 x UR2-H (2 x 9 slots), steel 2 • 1 x UR2-H (2 x 9 slots), steel 2 • 2 x UR2 (9 slots), aluminum 3 • 2 x UR2 (9 slots), aluminum 3 • 2 x UR2 (9 slots), steel 4 • 2 x UR2 (9 slots), steel 4 Power supply (without backup batteries) 10 Power supply (without backup batteries) • 2 x PS 407, 10 A for 120/230 V AC/DC B • 2 x PS 407, 10 A for 120/230 V AC/DC B • 2 x PS 407, 10 A for 120/230 V AC/DC, redundant design C • 2 x PS 407, 10 A for 120/230 V AC/DC, redundant design C • 2 x PS 407, 20 A for 120/230 V AC/DC D • 2 x PS 407, 20 A for 120/230 V AC/DC D • 2 x 2 PS 407, 10 A for 120/230 V AC/DC, redundant design E • 2 x 2 PS 407, 10 A for 120/230 V AC/DC, redundant design E • 2 x PS 405, 10 A for 24 V DC G • 2 x PS 405, 10 A for 24 V DC G • 2 x PS 405, 10 A for 24 V DC, redundant design H • 2 x PS 405, 10 A for 24 V DC, redundant design H • 2 x PS 405, 20 A for 24 V DC J • 2 x PS 405, 20 A for 24 V DC J • 2 x PS 405, 10 A for 24 V DC, redundant design K • 2 x PS 405, 10 A for 24 V DC, redundant design K Additive PROFIBUS DP interface modules1) Additive PROFIBUS DP interface modules1) • Without CP 443-5 Extended 0 • Without CP 443-5 Extended 0 • 2 x CP 443-5 Extended 1 • 2 x CP 443-5 Extended 1 • 2 x 2 CP 443-5 Extended1) 2 • 2 x 2 CP 443-5 Extended1) 2 • 2 x 3 CP 443-5 Extended1) 3 • 2 x 3 CP 443-5 Extended1) 3 • 2 x 4 CP 443-5 Extended1) 4 • 2 x 4 CP 443-5 Extended1) 4 1) Up to 5 CPs can be plugged in per subsystem with a single power supply, or up to 3 with a redundant power supply. 1) Up to 5 CPs can be plugged in per subsystem with a single power supply, or up to 3 with a redundant power supply. Siemens ST PCS 7 · Update November 2008 10/19 © Siemens AG 2008 Automation systems Fault-tolerant automation systems Recommended preferred types ■ Selection and Ordering Data ■ Selection and Ordering Data Order No. AS 412-3-1H automation system with SIMATIC PCS 7 AS Runtime license for 100 POs Preassembled and tested, without CP 443-5 Extended, without sync modules and cables, comprising: 1 x CPU 412-3H with one integrated interface (MPI/DP master), 768 KB main memory (512 KB for program and 256 KB for data), CP 443-1 communications processor for connection to Industrial Ethernet plant bus as well as • UR2 aluminum rack (9 slots) 6ES7 654-8CM01-3CB0 B) B) - PS 407 power supply; 10 A for 120/230 V AC/DC, redundant design, without backup batteries, memory card 4 MB RAM 6ES7 654-8EM01-3CB0 B) B) - PS 407 power supply; 10 A for 120/230 V AC/DC, redundant design, without backup batteries, memory card 16 MB RAM - PS 405 power supply; 10 A for 24 V DC, without backup batteries, memory card 4 MB RAM 6ES7 654-8CM01-3GB0 B) - PS 405 power supply; 10 A for 24 V DC, without backup batteries, memory card 16 MB RAM 6ES7 654-8EM01-3GB0 B) • UR2 aluminum rack (9 slots) 10 Order No. AS 417-4-1H automation system with SIMATIC PCS 7 AS Runtime license for 100 POs Preassembled and tested, without CP 443-5 Extended, without sync modules and cables, comprising: 1 x CPU 417-4H with 2 integrated interfaces (MPI/DP master and DP master), 30 MB main memory (15 MB each for program and data), CP 443-1 communications processor for connection to Industrial Ethernet plant bus as well as Fault-tolerant SIMATIC PCS 7 automation systems Single Stations, recommended preferred types - PS 407 power supply; 10 A for 120/230 V AC/DC, redundant design, without backup batteries, memory card 2 MB RAM 6ES7 654-8BA01-3CB0 - PS 405 power supply; 10 A for 24 V DC, without backup batteries, memory card 2 MB RAM 6ES7 654-8BA01-3GB0 AS 414-4-1H automation system with SIMATIC PCS 7 AS Runtime license for 100 POs Preassembled and tested, without CP 443-5 Extended, without sync modules and cables, comprising: 1 x CPU 414-4H with 2 integrated interfaces (MPI/DP master and DP master), 2.8 MB main memory (1.4 MB each for program and data), CP 443-1 communications processor for connection to Industrial Ethernet plant bus as well as Fault-tolerant SIMATIC PCS 7 automation systems Redundant stations, recommended preferred types • UR2 aluminum rack (9 slots) - PS 407 power supply; 10 A for 120/230 V AC/DC, redundant design, without backup batteries, memory card 2 MB RAM 6ES7 654-8BE01-3CB0 B) - PS 407 power supply; 10 A for 120/230 V AC/DC, redundant design, without backup batteries, memory card 4 MB RAM 6ES7 654-8CE01-3CB0 B) - PS 405 power supply; 10 A for 24 V DC, without backup batteries, memory card 2 MB RAM 6ES7 654-8BE01-3GB0 B) - PS 405 power supply; 10 A for 24 V DC, without backup batteries, memory card 4 MB RAM 6ES7 654-8CE01-3GB0 B) AS 412-3-2H automation system with SIMATIC PCS 7 AS Runtime license for 100 POs Preassembled and tested, without CP 443-5 Extended, comprising: 2 x CPU 412-3H with 2 x 1 integrated interface (MPI/DP master), 2 x 768 KB main memory (512 KB each for program and 256 KB each for data), two CP 443-1 communications processors for connection to Industrial Ethernet plant bus as well as • Aluminium UR2-H rack (2 x 9 slots), 4 sync modules for distances up to 10 m and 2 fiber-optic sync cables, 1 m - Two PS 407 power supplies; 10 A for 120/230 V AC/DC, redundant design, without backup batteries, 2 memory cards of 2 MB RAM each 6ES7 656-8BA31-1CB0 B) - Two PS 405 power supplies; 10 A for 24 V DC, without backup batteries, 2 memory cards of 2 MB RAM each 6ES7 656-8BA31-1GB0 B) B) Subject to export regulations: AL: N, ECCN: EAR99H 10/20 Siemens ST PCS 7 · Update November 2008 © Siemens AG 2008 Automation systems Fault-tolerant automation systems ■ Selection and Ordering Data ■ Selection and Ordering Data Order No. Order No. AS 417-4-2H automation system with SIMATIC PCS 7 AS Runtime license for 100 POs Preassembled and tested, without CP 443-5 Extended, comprising: 2 x CPU 417-4H with 2 x 2 integrated interfaces (MPI/DP master and DP master), 2 x 30 MB RAM (15 MB each for program and data), 2 x CP 443-1 communications processors for connection to Industrial Ethernet plant bus as well as AS 414-4-2H automation system with SIMATIC PCS 7 AS Runtime license for 100 POs Preassembled and tested, without CP 443-5 Extended, comprising: 2 x CPU 414-4H with 2 x 2 integrated interfaces (MPI/DP master and DP master), 2 x 2.8 MB main memory (1.4 MB each for program and data), 2 x CP 443-1 communications processors for connection to Industrial Ethernet plant bus as well as • Aluminium UR2-H rack (2 x 9 slots), 4 sync modules for distances up to 10 m and 2 fiber-optic sync cables, 1 m • Aluminium UR2-H rack (2 x 9 slots), 4 sync modules for distances up to 10 m and 2 fiber-optic sync cables, 1 m - Two PS 407 power supplies; 10 A for 120/230 V AC/DC, redundant design, without backup batteries, 2 memory cards of 2 MB RAM each 6ES7 656-8BE31-1CB0 B) - Two PS 407 power supplies; 10 A for 120/230 V AC/DC, redundant design, without backup batteries, 2 memory cards of 4 MB RAM each 6ES7 656-8CE31-1CB0 B) - Two PS 405 power supplies; 10 A for 24 V DC, without backup batteries, 2 memory cards of 2 MB RAM each 6ES7 656-8BE31-1GB0 B) - Two PS 405 power supplies; 10 A for 24 V DC, without backup batteries, 2 memory cards of 4 MB RAM each 6ES7 656-8CE31-1GB0 B) - Two PS 407 power supplies; 10 A for 120/230 V AC/DC, redundant design, without backup batteries, 2 memory cards of 4 MB RAM each 6ES7 656-8CM31-1CB0 B) - Two PS 407 power supplies; 10 A for 120/230 V AC/DC, redundant design, without backup batteries, 2 memory cards of 8 MB RAM each 6ES7 656-8DM31-1CB0 B) - Two PS 407 power supplies; 10 A for 120/230 V AC/DC, redundant design, without backup batteries, 2 memory cards of 16 MB RAM each 6ES7 656-8EM31-1CB0 B) - Two PS 405 power supplies; 10 A for 24 V DC, without backup batteries, 2 memory cards of 4 MB RAM each 6ES7 656-8CM31-1GB0 B) - Two PS 405 power supplies; 10 A for 24 V DC, without backup batteries, 2 memory cards of 8 MB RAM each 6ES7 656-8DM31-1GB0 B) - Two PS 405 power supplies; 10 A for 24 V DC, without backup batteries, 2 memory cards of 16 MB RAM each 6ES7 656-8EM31-1GB0 B) Runtime licenses for SIMATIC PCS 7 automation systems (can be added to existing licenses) SIMATIC PCS 7 AS Runtime license 6 languages (German, English, French, Italian, Spanish, Chinese), executes in the engineering system with Windows XP Professional, floating license for 1 installation Type of delivery: License key disk, certificate of license, terms and conditions • 100 POs 6ES7 653-2BA00-0XB5 • 1,000 POs 6ES7 653-2BB00-0XB5 • 10,000 POs 6ES7 653-2BC00-0XB5 B) Subject to export regulations: AL: N, ECCN: EAR99H Siemens ST PCS 7 · Update November 2008 10/21 10 © Siemens AG 2008 Automation systems Fault-tolerant automation systems Individual components ■ Selection and Ordering Data ■ Selection and Ordering Data Order No. Individual components of the fault-tolerant SIMATIC PCS 7 automation systems CPU 412-3H RAM 768 KB (512 KB for program and 256 KB for data) Module occupies 2 slots 6ES7 412-3HJ14-0AB0 B) CPU 414-4H RAM 2.8 MB (1.4 MB each for program and data) Module occupies 2 slots 6ES7 414-4HM14-0AB0 B) CPU 417-4H RAM 30 MB (15 MB each for program and data) Module occupies 2 slots 6ES7 417-4HT14-0AB0 B) Sync set For linking the two redundant 4123H, 414-4H or 417-4H CPUs; for distances up to • 10 m, consisting of 4 sync modules for up to 10 m and 2 fiberoptic sync cables, 1 m each 6ES7 656-7XX30-0XX0 • 10 km, consisting of 4 sync modules for up to 10 km Note: please order fiber-optic sync cables (2 units) in the required length separately. 6ES7 656-7XX40-0XX0 Sync module For linking the two CPUs 412-3H, 414-4H or 417-4H; two modules required per CPU For distances of up to 10 • 10 m 6ES7 960-1AA04-0XA0 • 10 km 6ES7 960-1AB04-0XA0 Sync cable (fiber-optic cable) For connecting the two 412-3H, 414-4H or 417-4H CPUs; each redundant automation system requires 2 cables •1m 6ES7 960-1AA04-5AA0 •2m 6ES7 960-1AA04-5BA0 • 10 m 6ES7 960-1AA04-5KA0 Other lengths auf Anfrage Memory Card RAM • 1 MB 6ES7 952-1AK00-0AA0 • 2 MB 6ES7 952-1AL00-0AA0 • 4 MB 6ES7 952-1AM00-0AA0 • 8 MB 6ES7 952-1AP00-0AA0 • 16 MB 6ES7 952-1AS00-0AA0 • 64 MB 6ES7 952-1AY00-0AA0 Memory Card Flash-EPROM Only required to update firmware. Alternative: firmware update via the engineering system • 8 MB 6ES7 952-1KP00-0AA0 Order No. CP 443-1 Communications processor for connection of SIMATIC S7-400 to Industrial Ethernet through TCP/IP, ISO and UDP; for S7 communication, S5-compatible communication (SEND/RECEIVE) with FETCH/WRITE with or without RFC 1006, diagnostics expansion, Multicast, commissioning through LAN 10/100 Mbit/s, with electronic manual on CD-ROM 6GK7 443-1EX11-0XE0 CP 443-5 Extended Communications processor for connection of SIMATIC S7-400 to PROFIBUS as DP master or for S7 communication, for increasing the number of DP lines, for data set routing with SIMATIC PDM and for 10-ms time stamp, electronic manual on CD; module occupies 1 slot 6GK7 443-5DX04-0XE0 PS 407 power supply module; 10 A 120/230 V AC/DC; 5 V DC/10 A, 24 V DC/1 A; with battery compartment for 2 backup batteries, module occupies 2 slots 6ES7 407-0KA02-0AA0 PS 407 power supply module; 10 A, redundant design 120/230 V AC/DC; 5 V DC/10 A, 24 V DC/1 A; with battery compartment for 2 backup batteries, module occupies 2 slots 6ES7 407-0KR02-0AA0 PS 407 power supply module; 20 A 120/230 V AC/DC; 5 V DC/20 A, 24 V DC/1 A; with battery compartment for 2 backup batteries, module occupies 2 slots 6ES7 407-0RA02-0AA0 PS 405 power supply module; 10 A 24 V DC; 5 V DC/10 A, 24 V DC/1 A; with battery compartment for 2 backup batteries, module occupies 2 slots 6ES7 405-0KA02-0AA0 PS 405 power supply module; 10 A, redundant design 24 V DC; 5 V DC/10 A, 24 V DC/1 A; with battery compartment for 2 backup batteries, module occupies 2 slots 6ES7 405-0KR02-0AA0 PS 405 power supply module; 20 A 24 V DC; 5 V DC/20 A, 24 V DC/1 A; with battery compartment for 2 backup batteries, module occupies 2 slots 6ES7 405-0RA02-0AA0 Backup battery Type AA, 2.3 Ah 6ES7 971-0BA00 B) Subject to export regulations: AL: N, ECCN: EAR99H 10/22 Siemens ST PCS 7 · Update November 2008 B) © Siemens AG 2008 Automation systems Fault-tolerant automation systems ■ Selection and Ordering Data ■ Options Order No. Aluminum UR1 rack 18 slots 6ES7 400-1TA11-0AA0 Aluminum UR2 rack 9 slots 6ES7 400-1JA11-0AA0 Aluminum UR2-H rack For divided central controllers; 2 x 9 slots 6ES7 400-2JA10-0AA0 Steel UR1 rack 18 slots 6ES7 400-1TA01-0AA0 Steel UR2 rack 9 slots 6ES7 400-1JA01-0AA0 Steel UR2-H rack For divided central controllers; 2 x 9 slots 6ES7 400-2JA00-0AA0 B) The Y-link comprises: • Two IM 153-2 High Feature interface modules for extended temperature range • One Y-coupler incl. RS 485 repeater • One IM157 (IM/IM) bus module for two IM 153-2 High Feature modules, for extended temperature range • One BM Y-coupler bus module Y-Link Y-Link For connection of devices with only one PROFIBUS DP interface to a fault-tolerant automation system 6ES7 197-1LA11-0XA0 Y-Link • Bus coupler for transition from a redundant PROFIBUS DP master system to a single-channel PROFIBUS DP master system • For connecting devices with only one PROFIBUS DP interface to the redundant PROFIBUS DP master system AS 412H / AS 414H / AS 417H B) Evaluation of the Y-Link diagnostics (and hence indirectly of the connected DP standard slaves) is supported by driver blocks. B) Subject to export regulations: AL: N, ECCN: EAR99H 10 Siemens ST PCS 7 · Update November 2008 10/23 © Siemens AG 2008 Automation systems Safety-related automation systems ■ Overview Safety-related automation systems are used for critical applications where a fault could endanger life or result in damage to the plant or the environment. These F/FH systems frequently referred to as "fail-safe automation systems" detect both faults in the process and their own internal faults in association with the safety-related F modules of the ET 200 distributed I/O systems or fail-safe transmitters connected directly via the fieldbus. They automatically transfer the plant to a safe state in the event of a fault. ■ Design In general, two design versions are differentiated across all architectural levels of a system based on Safety Integrated for Process Automation: • Single-channel, non-redundant design • Redundant, fault-tolerant design Even at the controller level, they can be combined in one system or separated. In addition, there are numerous possibilities arising from the use of flexible modular redundancy. These two design versions are highly variable and offer a wide scope for design with regard to different customer requirements. Standard (basic process control) and safety-related functions can be combined flexibly, not only in the area of distributed I/O. Distributed I/O and direct fieldbus interfacing Flexible Modular Redundancy at module or device level Redundant, high-availability and fault-tolerant configuration Distributed I/O AS 412F/ AS 414F/ AS 417F Direct fieldbus interfacing AS 412FH/ AS 414FH/ AS 417FH AS 412FH/ AS 414FH/ AS 417FH DP/PA Link ET 200M ET 200M PROFIBUS PA F-modules F-modules ET 200M Standard modules ET 200S ET 200M F- and standard modules ET 200M DP/PA Link with redundant DP/PA couplers Active field splitter PROFIBUS PA Standard modules F- and standard modules ET 200M Module or channel redundancy over several separate stations DP/PA Link PROFIBUS PA PROFIBUS DP F- and standard modules PROFIBUS DP ET 200M PROFIBUS DP 10 Single-channel, non-redundant configuration At the individual architectural levels (controller, fieldbus, distributed I/O) the configuration alternatives shown in the figure are available depending on the distributed I/O used (ET 200M and ET 200S remote I/O stations or PROFIBUS PA devices according to Profile 3.0). DP/PA Link with redundant DP/PA couplers Active field distributors F- and standard modules ET 200S Y-Link PROFIBUS PA Design versions for safety-related systems 10/24 Siemens ST PCS 7 · Update November 2008 © Siemens AG 2008 Automation systems Safety-related automation systems The safety-related SIMATIC PCS 7 automation systems at the controller level are categorized in accordance with the two design versions as follows: • Single stations AS 412F, AS 414F and AS 417F with only one CPU (safetyrelated) • Redundant stations AS 412FH, AS 414FH and AS 417FH with two redundant CPUs (safety-related and fault-tolerant) Single stations and redundant stations are available as preassembled and tested all-in-one systems (AS bundles) without extra charge. They are based on the hardware of the AS 412H, AS 414H or AS 417H fault-tolerant automation systems expanded by safety functions with S7 F Systems. Similar to the fault-tolerant systems used as a basis, the RAM of the safety-related AS bundles varies as follows: AS type RAM AS 412F/FH 768 KB (512 KB for program and 256 KB for data) AS 414F/FH 2.8 MB (1.4 MB each for program and data) AS 417F/FH 30 MB (15 MB each for program and data) All F/FH systems are TÜV-certified and comply with the safety requirements up to SIL 3 according to IEC 61508. In the systems with multitasking capability, several programs can be executed simultaneously in one CPU – basic process control (BPCS) applications or also safety-related applications. The programs are reaction-free, i.e. faults in BPCS applications have no effect on safety-related applications, and vice versa. Special tasks with very short response times can also be implemented. The redundant FH systems operating according to the 1-out-of2 principle consist of two subsystems of identical design. These are electrically isolated from each other to achieve optimum EMC, and are synchronized with each other via fiber-optic cables. A bumpless switchover is made from the active subsystem to the standby subsystem in the event of a fault. The two subsystems can be present in the same rack or separated by up to 10 km. The spatial separation provides additional security in the case of extreme influences in the environment of the active subsystem, e.g. resulting from a fire. Communication over the plant bus The safety-related automation systems are connected as standard to the plant bus using one communications processor per AS (F-systems) or sub-AS (FH-systems). The plant bus can be implemented in the form of a ring structure, which can also be configured with redundant architecture if the availability requirements are high. When there are two redundant rings it makes sense to use two communications processors per AS (F-systems) or sub-AS (FH-systems) and to distribute their connections between the two rings(4-way connection). Double faults such as failure of the OSM/SCALANCE switch on ring 1 with simultaneous interruption in the bus cable on ring 2 can thus be tolerated. Individual configuration of AS bundles The equipment of the safety-related automation systems as well as their Order Nos. can be individually compiled by selecting preconfigured ordering units. System-specific ordering configurations are available for this purpose in the following Section "Selection and ordering data". These are divided into: • Single stations: AS 412F, AS 414F and AS 417F with only one CPU • Redundant stations: AS 412FH, AS 414FH and AS 417FH with two redundant CPUs, mounted on one common rack (UR2-H) or two separate racks (UR2) In order to rapidly access the recommended preferred configurations, these are additionally listed with their complete order numbers. As an alternative to the ordering data in this catalog, the configurator offered in the catalog & online ordering system "A&D Mall" (www.siemens.com/automation/mall) can also be used to select and order safety-related automation systems for SIMATIC PCS 7. Ordering information The AS 412F/FH automation systems currently only support sync modules with a range up to 10 m. Fiber-optic sync cables longer than 1 m must always be ordered separately (2 of each required). The redundancy of the FH systems is only used to increase the availability. It is not relevant to processing of the safety functions and the associated fault detection. Runtime licenses Each AS bundle is already provided as standard with the SIMATIC PCS 7 AS Runtime license for 100 process objects (PO). The number of process objects can be extended by additional Runtime licenses for 100, 1000 or 10000 POs. The process objects of additional Runtime licenses can be added to process objects which already exist. The number and type (e.g. 100 or 1000) of additional Runtime licenses are irrelevant. The AS Runtime licenses are administered on a SIMATIC PCS 7 engineering system or in the SIMATIC PCS 7 BOX. Siemens ST PCS 7 · Update November 2008 10/25 10 © Siemens AG 2008 Automation systems Safety-related automation systems ■ Function ■ Options Safety functions Ordering information The safety functions of an application are implemented by the safety-related program executed in the CPU of the F/FH systems together with the safety-related F-modules of the ET 200 distributed I/O systems or directly by failsafe transmitters connected via the fieldbus. An AS 412H, AS 414H or AS 417H system is required as the hardware for a safety-related automation system. The PROFIsafe profile is used for the safe PROFIBUS DP communication between CPU and process I/O. PROFIsafe expands the message frames by additional information with which the PROFIsafe communications partners can recognize and compensate transmission errors such as delays, incorrect sequences, repetitions, losses, faulty addressing or data falsification. Standard modules can be used in F/FH systems in addition to safety-related F-modules - mixed in a remote I/O station or in separate stations, in a common PROFIBUS segment or in separate PROFIBUS segments. Basic process control (BPCS) applications and safety applications can be automated in such mixed configurations with one and the same system and configured with uniform standard tools. One CPU processes BPCS and safety functions in parallel. Mutual interference during processing is prevented by ensuring that the BPCS programs and the safety-related programs are kept strictly separate and that the data exchange is by means of special conversion function blocks. The safety functions are processed twice in different sections of a CPU by means of redundant, diverse instruction processing. Potential errors are detected by the system during the subsequent comparison of results. 10 The S7 F Systems engineering tool as a component of the SIMATIC Manager allows parameterization of the F/FH systems and the safety-related F-modules from the ET 200 series. It supports configuration by means of functions for: • Comparison of safety-related F-programs • Recognition of changes in the F-program using the checksum • Separation of safety-related and standard functions. Access to the F-functions can be password-protected. The F-block library integrated in S7 F Systems contains predefined function blocks for generation of safety-related applications with the CFC or the SIMATIC Safety Matrix based on it. The certified F-blocks are extremely robust and intercept programming errors such as division by zero or out-of-range values. They avoid the need for diverse programming tasks for detecting and reacting to errors. 10/26 Siemens ST PCS 7 · Update November 2008 The following H systems can be used depending on the type and structure of the safety-related automation system: • For single-channel AS 412F, AS 414F or AS 417F safety-related systems: one each of AS 412-3-1H, AS 414-4-1H or AS 417-4-1H • For fault-tolerant and safety-related AS 412FH, AS 414FH or AS 417FH systems: - With both subsystems in one rack: one each of AS 412-3-2H, AS 414-4-2H or AS 417-4-2H - With the two subsystems in different racks: two each of AS 412-3-1H, AS 414-4-1H or AS 417-4-1H You require the following components in addition: • S7 F Systems F programming tool with F block library for programming safety-related user programs on the engineering system (see Chapter "Engineering system") • F Runtime license For processing safety-related user programs, for one AS 412F/FH, AS 414F/FH or AS 417F/FH system • Option: SIMATIC Safety Matrix The convenient safety lifecycle tool for configuration of operation and servicing (see Chapter "Engineering system") © Siemens AG 2008 Automation systems Safety-related automation systems Order No. Selection and ordering data AS 414F (Single Station) with SIMATIC PCS 7 AS Runtime license for 100 POs CPU with 2 interfaces (MPI/DP master and DP master) 2.8 MB RAM (1.4 MB each for program and data) Type of delivery Type of delivery • Preassembled and tested Order No. Selection and ordering data AS 412F (Single Station) 6ES7 654with SIMATIC PCS 7 AS Runtime license for 7 7 7 7 7 - 7 7 B7 100 POs CPU with 1 interface (MPI/DP master) 768 KB RAM (512 KB for program and 256 KB for data) 6ES7 6547 7 7 7 7 - 7 7 B7 • Preassembled and tested 8 Memory card 8 Memory card • Memory card 1 MB RAM (up to approx. 50 POs) A • Memory card 2 MB RAM (up to approx. 180 POs) B • Memory card 2 MB RAM (up to approx. 180 POs) B • Memory card 4 MB RAM (up to approx. 300 POs) C CPU type CPU type • CPU 412-3H with S7 F Systems RT license (up to approx. 50 POs) • CPU 414-4H with S7 F Systems RT license (up to approx. 250 POs) B Additive interface modules F Additive interface modules • Without additive interface module • Without additive interface module 0 Interface module to Industrial Ethernet plant bus1) 0 Interface module to Industrial Ethernet plant bus1) • 1 x CP 443-11) • 1 x CP 443-11) 1 1) • 2 x CP 443-1 for redundant interface module 1 1) • 2 x CP 443-1 for redundant interface module 2 Rack 2 Rack • UR2 (9 slots), aluminum 3 • UR2 (9 slots), aluminum 3 • UR2 (9 slots), steel 4 • UR2 (9 slots), steel 4 • UR1 (18 slots), aluminum 5 • UR1 (18 slots), aluminum 5 • UR1 (18 slots), steel 6 • UR1 (18 slots), steel 6 Power supply (without backup batteries) Power supply (without backup batteries) • 1 x PS 407, 10 A for 120/230 V AC/DC B • 1 x PS 407, 10 A for 120/230 V AC/DC B • 1 x PS 407, 10 A for 120/230 V AC/DC, redundancy possible C • 1 x PS 407, 10 A for 120/230 V AC/DC, redundancy possible C • 1 x PS 407, 20 A for 120/230 V AC/DC D • 1 x PS 407, 20 A for 120/230 V AC/DC D • 2 x PS 407, 10 A for 120/230 V AC/DC, redundancy possible E • 2 x PS 407, 10 A for 120/230 V AC/DC, redundancy possible E • 1 x PS 405, 10 A for 24 V DC G • 1 x PS 405, 10 A for 24 V DC G • 1 x PS 405, 10 A for 24 V DC, redundancy possible H • 1 x PS 405, 10 A for 24 V DC, redundancy possible H • 1 x PS 405, 20 A for 24 V DC J • 1 x PS 405, 20 A for 24 V DC J • 2 x PS 405, 10 A for 24 V DC, redundancy possible K • 2 x PS 405, 10 A for 24 V DC, redundancy possible K Additive PROFIBUS DP interface modules1) 10 Additive PROFIBUS DP interface modules1) • Without CP 443-5 Extended 0 • Without CP 443-5 Extended 0 • 1 x CP 443-5 Extended 1 • 1 x CP 443-5 Extended 1 Extended1) • 3 x CP 443-5 Extended1) • 4 x CP 443-5 Extended1) • 2 x CP 443-5 1) Up to 5 CPs can be plugged into the UR2 rack with a single power supply, or up to 3 with a redundant power supply. 2 • 2 x CP 443-5 Extended1) 2 3 • 3 x CP 443-5 Extended1) 3 4 • 4 x CP 443-5 Extended1) 4 1) Up to 5 CPs can be plugged into the UR2 rack with a single power supply, or up to 3 with a redundant power supply. Siemens ST PCS 7 · Update November 2008 10/27 © Siemens AG 2008 Automation systems Safety-related automation systems Selection and ordering data Order No. Selection and ordering data AS 417F (Single Station) with SIMATIC PCS 7 AS Runtime license for 100 POs CPU with 2 interfaces (MPI/DP master and DP master) 30 MB RAM (15 MB each for program and data) 6ES7 654- AS 412FH (Redundant Station) 6ES7 656with SIMATIC PCS 7 AS Runtime license for 7 7 7 7 7 - 7 7 B7 100 POs 2 x CPU with 1 interface each (MPI/DP master) 2 x 768 KB RAM (512 KB each for program and 256 KB each for data) 7 7 7 7 7 - 7 7 B7 Type of delivery Type of delivery • Preassembled and tested • Preassembled and tested 8 Memory card 8 Memory card • Memory card 4 MB RAM (up to approx. 300 POs) C • 2 x memory card 1 MB RAM (up to approx. 50 POs) A • Memory card 8 MB RAM (up to approx. 800 POs) D • 2 x memory card 2 MB RAM (up to approx. 180 POs) B • Memory card 16 MB RAM (up to approx. 3,000 POs) E CPU type CPU type • CPU 417-4H with S7 F Systems RT license (up to approx. 2,500 POs) • 2 x CPU 412-3H with S7 F Systems RT license (up to approx. 50 POs) N Additive interface modules B Sync modules and cables • Without additive interface module 0 • 1 x IF 964-DP 1 • 2 x 2 sync modules for distances up to 10 m and 2 x FO sync cable, 1 m Interface module to Industrial Ethernet plant bus1) 3 Interface module to Industrial Ethernet plant bus1) • 1 x CP 443-11) 1) • 2 x CP 443-1 for redundant interface module 1 • 2 x CP 443-1 for redundant interface module1) 1 2 • 2 x 2 CP 443-1 for 4-way connection1) 2 Rack 10 Order No. Rack • UR2 (9 slots), aluminum 3 • 1 x UR2-H (2 x 9 slots), aluminum 1 • UR2 (9 slots), steel 4 • 1 x UR2-H (2 x 9 slots), steel 2 • UR1 (18 slots), aluminum 5 • 2 x UR2 (9 slots), aluminum 3 • UR1 (18 slots), steel 6 • 2 x UR2 (9 slots), steel 4 Power supply (without backup batteries) Power supply (without backup batteries) • 1 x PS 407, 10 A for 120/230 V AC/DC B • 2 x PS 407, 10 A for 120/230 V AC/DC B • 1 x PS 407, 10 A for 120/230 V AC/DC, redundancy possible C • 2 x PS 407, 10 A for 120/230 V AC/DC, redundancy possible C • 1 x PS 407, 20 A for 120/230 V AC/DC D • 2 x PS 407, 20 A for 120/230 V AC/DC D • 2 x PS 407, 10 A for 120/230 V AC/DC, redundancy possible E • 2 x 2 PS 407, 10 A for 120/230 V AC/DC, edundancy possible E • 1 x PS 405, 10 A for 24 V DC G • 2 x PS 405, 10 A for 24 V DC G • 1 x PS 405, 10 A for 24 V DC, redundancy possible H • 2 x PS 405, 10 A for 24 V DC, redundancy possible, H • 1 x PS 405, 20 A for 24 V DC J • 2 x PS 405, 20 A for 24 V DC J • 2 x PS 405, 10 A for 24 V DC, redundancy possible K • 2 x PS 405, 10 A for 24 V DC, redundancy possible K Additive PROFIBUS DP interface modules1) Additive PROFIBUS DP interface modules1) • Without CP 443-5 Extended 0 • Without CP 443-5 Extended 0 • 1 x CP 443-5 Extended 1 • 2 x CP 443-5 Extended 1 • 2 x CP 443-5 Extended1) 2 • 2 x 2 CP 443-5 Extended1) 2 • 3 x CP 443-5 Extended1) 3 • 2 x 3 CP 443-5 Extended1) 3 • 4 x CP 443-5 Extended1) 4 • 2 x 4 CP 443-5 Extended1) 4 1) Up to 5 CPs can be plugged into the UR2 rack with a single power supply, or up to 3 with a redundant power supply. 10/28 Siemens ST PCS 7 · Update November 2008 1) Up to 5 CPs can be plugged in per subsystem with a single power supply, or up to 3 with a redundant power supply. © Siemens AG 2008 Automation systems Safety-related automation systems Selection and ordering data Order No. Selection and ordering data AS 414FH (Redundant Station) 6ES7 656with SIMATIC PCS 7 AS Runtime license for 7 7 7 7 7 - 7 7 B7 100 POs 2 x CPU with 2 interfaces (MPI/DP master and DP master) 2 x 2.8 MB RAM (1.4 MB each for program and data) AS 417FH (Redundant Station) with SIMATIC PCS 7 AS Runtime license for 100 POs 2 x CPU with 2 interfaces (MPI/DP master and DP master) 2 x 30 MB RAM (15 MB each for program and data) Type of delivery Type of delivery • Preassembled and tested • Preassembled and tested 8 Memory card Order No. 6ES7 6567 7 7 7 7 - 7 7 B7 8 Memory card • 2 x memory card 2 MB RAM (up to approx. 180 POs) B • 2 x memory card 4 MB RAM (up to approx. 300 POs) C • 2 x memory card 4 MB RAM (up to approx. 300 POs) C • 2 x memory card 8 MB RAM (up to approx. 800 POs) D • 2 x memory card 16 MB RAM (up to approx. 3,000 POs) E CPU type CPU type • 2 x CPU 414-4H with S7 F Systems RT license (up to approx. 250 POs) • 2 x CPU 417-4H with S7 F Systems RT license (up to approx. 2,500 POs) F Sync modules and cables N Sync modules and cables • 2 x 2 sync modules for distances up to 10 m and 2 x FO sync cable, 1 m 3 • 2 x 2 sync modules for distances up to 10 m and 2 x FO sync cable, 1 m 3 • 2 x 2 sync modules for up to 10 km and 2 x FO sync cable, 1 m, for testing 4 • 2 x 2 sync modules for up to 10 km and 2 x FO sync cable, 1 m, for testing 4 Interface module to Industrial Ethernet plant bus1) • 2 x CP 443-1 for redundant interface module1) • 2 x 2 CP 443-1 for 4-way connection1) Interface module to Industrial Ethernet plant bus1) 1 • 2 x CP 443-1 for redundant interface module1) 1 2 • 2 x 2 CP 443-1 for 4-way connection1) 2 Rack Rack • 1 x UR2-H (2 x 9 slots), aluminum 1 • 1 x UR2-H (2 x 9 slots), aluminum 1 • 1 x UR2-H (2 x 9 slots), steel 2 • 1 x UR2-H (2 x 9 slots), steel 2 • 2 x UR2 (9 slots), aluminum 3 • 2 x UR2 (9 slots), aluminum 3 • 2 x UR2 (9 slots), steel 4 • 2 x UR2 (9 slots), steel 4 Power supply (without backup batteries) 10 Power supply (without backup batteries) • 2 x PS 407, 10 A for 120/230 V AC/DC B • 2 x PS 407, 10 A for 120/230 V AC/DC B • 2 x PS 407, 10 A for 120/230 V AC/DC, redundancy possible C • 2 x PS 407, 10 A for 120/230 V AC/DC, redundancy possible C • 2 x PS 407, 20 A for 120/230 V AC/DC D • 2 x PS 407, 20 A for 120/230 V AC/DC D • 2 x 2 PS 407, 10 A for 120/230 V AC/DC, redundancy possible E • 2 x 2 PS 407, 10 A for 120/230 V AC/DC, redundancy possible E • 2 x PS 405, 10 A for 24 V DC G • 2 x PS 405, 10 A for 24 V DC G • 2 x PS 405, 10 A for 24 V DC, redundancy possible H • 2 x PS 405, 10 A for 24 V DC, redundancy possible H • 2 x PS 405, 20 A for 24 V DC J • 2 x PS 405, 20 A for 24 V DC J • 2 x PS 405, 10 A for 24 V DC, redundancy possible K • 2 x PS 405, 10 A for 24 V DC, redundancy possible K Additive PROFIBUS DP interface modules1) Additive PROFIBUS DP interface modules1) • Without CP 443-5 Extended 0 • Without CP 443-5 Extended 0 • 2 x CP 443-5 Extended 1 • 2 x CP 443-5 Extended 1 • 2 x 2 CP 443-5 Extended1) 2 • 2 x 2 CP 443-5 Extended1) 2 • 2 x 3 CP 443-5 Extended1) 3 • 2 x 3 CP 443-5 Extended1) 3 • 2 x 4 CP 443-5 Extended1) 4 • 2 x 4 CP 443-5 Extended1) 4 1) Up to 5 CPs can be plugged in per subsystem with a single power supply, or up to 3 with a redundant power supply. 1) Up to 5 CPs can be plugged in per subsystem with a single power supply, or up to 3 with a redundant power supply. Siemens ST PCS 7 · Update November 2008 10/29 © Siemens AG 2008 Automation systems Safety-related automation systems Recommended preferred types ■ Selection and Ordering Data ■ Selection and Ordering Data Order No. AS 412F automation system with SIMATIC PCS 7 AS Runtime license for 100 POs Preassembled and tested, without CP 443-5 Extended, without sync modules and cables, comprising: 1 x CPU 412-3H with one integrated interface (MPI/DP master) and S7 F Systems RT license, 768 KB RAM (512 KB for program and 256 KB for data) as well as • UR2 aluminum rack (9 slots) • UR2 aluminum rack (9 slots) 10 Order No. AS 414F automation system with SIMATIC PCS 7 AS Runtime license for 100 POs Preassembled and tested, without CP 443-5 Extended, without sync modules and cables, comprising: 1 x CPU 414-4H with 2 integrated interfaces (MPI/DP master and DP master) and S7 F Systems RT license, 2.8 MB RAM (1.4 MB each for program and data) as well as Safety-related SIMATIC PCS 7 automation systems Single Stations, recommended preferred types - PS 407 power supply; 10 A for 120/230 V AC/DC, without backup batteries, memory card 1 MB RAM, 1 x CP 443-1 communications processor for connection to plant bus 6ES7 654-8AB01-3BB0 B) - PS 407 power supply; 10 A for 120/230 V AC/DC, without backup batteries, memory card 1 MB RAM, 2 x CP 443-1 communications processor for connection to plant bus 6ES7 654-8AB02-3BB0 B) - PS 405 power supply; 10 A for 24 V DC, without backup batteries, memory card 1 MB RAM, 1 x CP 443-1 communications processor for connection to plant bus 6ES7 654-8AB01-3GB0 B) - PS 405 power supply; 10 A for 24 V DC, without backup batteries, memory card 1 MB RAM, 2 x CP 443-1 communications processor for connection to plant bus 6ES7 654-8AB02-3GB0 B) - PS 407 power supply; 10 A for 120/230 V AC/DC, without backup batteries, memory card 4 MB RAM, 1 x CP 443-1 communications processor for connection to plant bus 6ES7 654-8CF01-3BB0 B) - PS 407 power supply; 10 A for 120/230 V AC/DC, without backup batteries, memory card 4 MB RAM, 2 x CP 443-1 communications processor for connection to plant bus 6ES7 654-8CF02-3BB0 B) - PS 405 power supply; 10 A for 24 V DC, without backup batteries, memory card 4 MB RAM, 1 x CP 443-1 communications processor for connection to plant bus 6ES7 654-8CF01-3GB0 B) - PS 405 power supply; 10 A for 24 V DC, without backup batteries, memory card 4 MB RAM, 2 x CP 443-1 communications processor for connection to plant bus 6ES7 654-8CF02-3GB0 B) B) Subject to export regulations: AL: N, ECCN: EAR99H 10/30 Siemens ST PCS 7 · Update November 2008 © Siemens AG 2008 Automation systems Safety-related automation systems ■ Selection and Ordering Data ■ Selection and Ordering Data Order No. AS 417F automation system with SIMATIC PCS 7 AS Runtime license for 100 POs Preassembled and tested, without CP 443-5 Extended, without sync modules and cables, comprising: 1 x CPU 417-4H with 2 integrated interfaces (MPI/DP master and DP master) and S7 F Systems RT license, 30 MB RAM (15 MB each for program and data) as well as Order No. Safety-related SIMATIC PCS 7 automation systems Redundant Stations, recommended preferred types • UR2 aluminum rack (9 slots) - PS 407 power supply; 10 A for 120/230 V AC/DC, without backup batteries, memory card 16 MB RAM, 1 x CP 4431 communications processor for connection to plant bus 6ES7 654-8EN01-3BB0 B) - PS 407 power supply; 10 A for 120/230 V AC/DC, without backup batteries, memory card 16 MB RAM, 2 x CP 4431 communications processor for connection to plant bus 6ES7 654-8EN02-3BB0 B) - PS 405 power supply; 10 A for 24 V DC, without backup batteries, memory card 16 MB RAM, 1 x CP 443-1 communications processor for connection to plant bus 6ES7 654-8EN01-3GB0 B) - PS 405 power supply; 10 A for 24 V DC, without backup batteries, memory card 16 MB RAM, 2 x CP 443-1 communications processor for connection to plant bus 6ES7 654-8EN02-3GB0 AS 412FH automation system with SIMATIC PCS 7 AS Runtime license for 100 POs Preassembled and tested, without CP 443-5 Extended, comprising: 2 x CPU 412-3H, each with integrated interface (MPI/DP master) and S7 F Systems RT license, 2 x 768 KB RAM (512 KB each for program and 256 KB each for data) as well as • Aluminium UR2-H rack (2 x 9 slots), 4 sync modules for distances up to 10 m and 2 fiber-optic sync cables, 1 m B) - 2 x 2 PS 407 power supplies; 10 A for 120/230 V AC/DC, redundancy possible, without backup batteries, 2 memory cards with 1 MB RAM each, 2 x CP 443-1 communications processor for connection to plant bus 6ES7 656-8AB31-1EB0 B) - 2 x 2 PS 407 power supplies; 10 A for 120/230 V AC/DC, redundancy possible, without backup batteries, 2 memory cards with 1 MB RAM each, 2 x 2 CP 443-1 communications processors for connection to plant bus 6ES7 656-8AB32-1EB0 B) - 2 PS 405 power supplies; 10 A for 24 V DC, without backup batteries, 2 memory cards with 1 MB RAM each, 2 x CP 443-1 communications processors for connection to plant bus 6ES7 656-8AB31-1GB0 B) - 2 PS 405 power supplies; 10 A for 24 V DC, without backup batteries, 2 memory cards with 1 MB RAM each, 2 x 2 CP 4431 communications processors for connection to plant bus 6ES7 656-8AB32-1GB0 B) B) Subject to export regulations: AL: N, ECCN: EAR99H Siemens ST PCS 7 · Update November 2008 10/31 10 © Siemens AG 2008 Automation systems Safety-related automation systems ■ Selection and Ordering Data 10 ■ Selection and Ordering Data Order No. AS 414FH automation system with SIMATIC PCS 7 AS Runtime license for 100 POs Preassembled and tested, without CP 443-5 Extended, comprising: 2 x CPU 414-4H, each with 2 integrated interfaces (MPI/DP master and DP master) and S7 F Systems RT license, 2 x 2.8 MB RAM (1.4 MB each for program and data) as well as AS 417FH automation system with SIMATIC PCS 7 AS Runtime license for 100 POs Preassembled and tested, without CP 443-5 Extended, comprising: 2 x CPU 417-4H, each with 2 integrated interfaces (MPI/DP master and DP master) and S7 F Systems RT license, 2 x 30 MB RAM (15 MB each for program and data) as well as • Aluminium UR2-H rack (2 x 9 slots), 4 sync modules for distances up to 10 m and 2 fiber-optic sync cables, 1 m • Aluminium UR2-H rack (2 x 9 slots), 4 sync modules for distances up to 10 m and 2 fiber-optic sync cables, 1 m Order No. - 2 x 2 PS 407 power supplies; 10 A for 120/230 V AC/DC, redundancy possible, without backup batteries, 2 memory cards with 4 MB RAM each, 2 x CP 443-1 communications processor for connection to plant bus 6ES7 656-8CF31-1EB0 B) - 2 x 2 PS 407 power supplies; 10 A for 120/230 V AC/DC, redundancy possible, without backup batteries, 2 memory cards with 16 MB RAM each, 2 x CP 443-1 communications processor for connection to plant bus 6ES7 656-8EN31-1EB0 B) - 2 x 2 PS 407 power supplies; 10 A for 120/230 V AC/DC, redundancy possible, without backup batteries, 2 memory cards with 4 MB RAM each, 2 x 2 CP 443-1 communications processors for connection to plant bus 6ES7 656-8CF32-1EB0 B) - 2 x 2 PS 407 power supplies; 10 A for 120/230 V AC/DC, redundancy possible, without backup batteries, 2 memory cards 16 MB RAM, 2 x 2 CP 443-1 communications processors for connection to plant bus 6ES7 656-8EN32-1EB0 B) - 2 PS 405 power supplies; 10 A for 24 V DC, without backup batteries, 2 memory cards with 4 MB RAM each, 2 x CP 443-1 communications processors for connection to plant bus 6ES7 656-8CF31-1GB0 B) - 2 PS 405 power supplies; 10 A for 24 V DC, without backup batteries, 2 memory cards with 16 MB RAM each, 2 x CP 4431 communications processors for connection to plant bus 6ES7 656-8EN31-1GB0 B) - 2 PS 405 power supplies; 10 A for 24 V DC, without backup batteries, 2 memory cards with 4 MB RAM each, 2 x 2 CP 4431 communications processors for connection to plant bus 6ES7 656-8CF32-1GB0 B) - 2 PS 405 power supplies; 10 A for 24 V DC, without backup batteries, 2 memory cards with 16 MB RAM each, 2 x 2 CP 443-1 communications processors for connection to plant bus 6ES7 656-8EN32-1GB0 B) Runtime licenses for SIMATIC PCS 7 automation systems (can be added to existing licenses) SIMATIC PCS 7 AS Runtime license 6 languages (German, English, French, Italian, Spanish, Chinese), executes in the engineering system with Windows XP Professional, floating license for 1 installation Type of delivery: License key disk, certificate of license, terms and conditions • 100 POs 6ES7 653-2BA00-0XB5 • 1,000 POs 6ES7 653-2BB00-0XB5 • 10,000 POs 6ES7 653-2BC00-0XB5 AS 412F/FH, AS 414F/FH and AS 417F/FH engineering (see Chapter "Engineering System", Section "Engineering Process Safety") B) Subject to export regulations: AL: N, ECCN: EAR99H 10/32 Siemens ST PCS 7 · Update November 2008 © Siemens AG 2008 Automation systems Safety-related automation systems Individual components ■ Selection and Ordering Data ■ Selection and Ordering Data Order No. S7 F Systems RT License For processing safety-related application programs, for one AS 412F/FH, AS 414F/FH or AS 417F/FH system 6ES7 833-1CC00-6YX0 B) CPU 412-3H RAM 768 KB (512 KB for program and 256 KB for data) Module occupies 2 slots 6ES7 412-3HJ14-0AB0 CPU 414-4H RAM 2.8 MB (1.4 MB each for program and data) Module occupies 2 slots 6ES7 414-4HM14-0AB0 B) CPU 417-4H RAM 30 MB (15 MB each for program and data) Module occupies 2 slots 6ES7 417-4HT14-0AB0 B) Sync set For linking the two redundant 412-3H, 414-4H or 417-4H CPUs; for distances up to • 10 m, consisting of 4 sync modules for up to 10 m and 2 fiberoptic sync cables, 1 m each 6ES7 656-7XX30-0XX0 • 10 km, consisting of 4 sync modules for up to 10 km Note: please order fiber-optic sync cables (2 units) in the required length separately. 6ES7 656-7XX40-0XX0 Sync module For linking the two 412-3H, 414-4H or 417-4H CPUs; two modules required per CPU For distances of up to • 10 m 6ES7 960-1AA04-0XA0 • 10 km 6ES7 960-1AB04-0XA0 Sync cable (fiber-optic cable) For connecting the two 412-3H, 414-4H or 417-4H CPUs; each redundant automation system requires 2 cables •1m 6ES7 960-1AA04-5AA0 •2m 6ES7 960-1AA04-5BA0 • 10 m 6ES7 960-1AA04-5KA0 Other lengths auf Anfrage Order No. Memory Card RAM Individual components of the safety-related SIMATIC PCS 7 automation systems • 1 MB 6ES7 952-1AK00-0AA0 • 2 MB 6ES7 952-1AL00-0AA0 • 4 MB 6ES7 952-1AM00-0AA0 • 8 MB 6ES7 952-1AP00-0AA0 • 16 MB 6ES7 952-1AS00-0AA0 • 64 MB 6ES7 952-1AY00-0AA0 Memory Card Flash-EPROM Only required to update firmware; alternative: firmware update via the engineering system • 8 MB 6ES7 952-1KP00-0AA0 CP 443-1 Communications processor for connection of SIMATIC S7-400 to Industrial Ethernet through TCP/IP, ISO and UDP; for S7 communication, S5-compatible communication (SEND/RECEIVE) with FETCH/WRITE with or without RFC 1006, diagnostics expansion, Multicast, commissioning through LAN 10/100 Mbit/s, with electronic manual on CD-ROM 6GK7 443-1EX11-0XE0 CP 443-5 Extended Communications processor for connection of SIMATIC S7-400 to PROFIBUS as DP master or for S7 communication, for increasing the number of DP lines, for data set routing with SIMATIC PDM and for 10-ms time stamp, electronic manual on CD; module occupies 1 slot 6GK7 443-5DX04-0XE0 PS 407 power supply module; 10 A 120/230 V AC/DC; 5 V DC/10 A, 24 V DC/1 A; with battery compartment for 2 backup batteries, module occupies 2 slots 6ES7 407-0KA02-0AA0 PS 407 power supply module; 10 A, redundant design possible 120/230 V AC/DC; 5 V DC/10 A, 24 V DC/1 A; with battery compartment for 2 backup batteries, module occupies 2 slots 6ES7 407-0KR02-0AA0 10 B) Subject to export regulations: AL: N, ECCN: EAR99H Siemens ST PCS 7 · Update November 2008 10/33 © Siemens AG 2008 Automation systems Safety-related automation systems ■ Selection and Ordering Data 6ES7 407-0RA02-0AA0 PS 405 power supply module; 10 A 24 V DC; 5 V DC/10 A, 24 V DC/1 A; with battery compartment for 2 backup batteries, module occupies 2 slots 6ES7 405-0KA02-0AA0 PS 405 power supply module; 10 A, redundant design possible 24 V DC; 5 V DC/10 A, 24 V DC/1 A; with battery compartment for 2 backup batteries, module occupies 2 slots 6ES7 405-0KR02-0AA0 PS 405 power supply module; 20 A 24 V DC; 5 V DC/20 A, 24 V DC/1 A; with battery compartment for 2 backup batteries, module occupies 2 slots 6ES7 405-0RA02-0AA0 Backup battery Type AA, 2.3 Ah 6ES7 971-0BA00 B) Order No. Aluminum UR1 rack 18 slots 6ES7 400-1TA11-0AA0 Aluminum UR2 rack 9 slots 6ES7 400-1JA11-0AA0 Aluminum UR2-H rack For divided central controllers; 2 x 9 slots 6ES7 400-2JA10-0AA0 Steel UR1 rack 18 slots 6ES7 400-1TA01-0AA0 Steel UR2 rack 9 slots 6ES7 400-1JA01-0AA0 Steel UR2-H rack For divided central controllers; 2 x 9 slots 6ES7 400-2JA00-0AA0 B) Subject to export regulations: AL: N, ECCN: EAR99H 10 10/34 ■ Selection and Ordering Data Order No. PS 407 power supply module; 20 A 120/230 V AC/DC; 5 V DC/20 A, 24 V DC/1 A; with battery compartment for 2 backup batteries, module occupies 2 slots Siemens ST PCS 7 · Update November 2008 B) © Siemens AG 2007 Process I/O 11/2 Introduction 11/4 11/4 11/5 Central I/O Central I/O modules Expansion units for central I/O 11/6 SIMATIC PCS 7 MTA terminal module 11/9 11/9 11/10 11/11 11/12 11/13 11/14 11/16 11/18 ET 200M distributed I/O Introduction Power supply Interface modules ET 200M accessories Bundles DI - digital input modules DO - digital output modules DI/DO - digital input/output modules AI - analog input modules AO - analog output modules Ex modules [EEi xb] Modules with HART F modules Closed-loop control modules Counter modules 11/19 11/21 11/22 11/23 11/25 11/27 11/29 11/30 11/30 11/32 11/33 11/34 11/37 11/38 11/39 11/39 11/41 11/43 11/44 11/45 11/47 11/49 11/53 ET 200S distributed I/O Introduction Terminal modules Interface modules Power modules Digital electronics modules Analog electronics modules Motor starters SIGUARD safety technology 11/56 11/56 11/59 ET 200pro distributed I/O Introduction Interface module IM 154-2 DP High Feature Digital electronics modules EM 141, EM 142 Analog electronics modules EM 144, EM 145 Safety-related electronics modules Power module PM-E 11/60 11/61 11/63 11/64 ET 200iSP distributed I/O Introduction ET 200iSP power supply unit IM 152-1 interface module Electronics modules and watchdog module RS 485-IS coupler Stainless steel wall enclosure Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Process I/O Introduction ■ Overview The SIMATIC PCS 7 process control system offers various possibilities for connecting I/O devices and for detecting and emitting process signals through sensors and actuators: • Analog and digital I/O modules of the SIMATIC S7-400 operated centrally in the automation system • ET 200M, ET 200S, ET 200iSP and ET 200pro remote I/O stations with an extensive range of cost-effective signal and function modules, connected through PROFIBUS DP to the automation system (AS) • Direct AS connection of intelligent, distributed field/process devices and operator terminals through PROFIBUS DP/PA (redundant or in hazardous zones 0, 1, 2 or 20, 21, 22 also possible) Signal groups of the SIMATIC S7-400 can be operated centrally in the automation system and are mainly used in small applications or systems of limited distributed expansion. Distributed process I/Os are mainly used nowadays: ET 200 remote I/Os in conjunction with classical field/process devices and HART field devices or intelligent field/process devices directly on PROFIBUS. Decisive for this are properties such as: • Modularity and consistency • Flexible adaptability to the plant structure • Minimum cabling and engineering requirements • Low commissioning, servicing and lifecycle costs • Wide technical bandwidth ■ Design Integration of I/O modules in the hazardous area Process control system Industrial Ethernet GAS FM/UL Class I Zone 2 Class I Zone 1 Class I Zone 0 ATEX Zone 2 Zone 1 Zone 0 DUST FM/UL Class II Zone 2 Class II Zone 1 Class II Zone 0 ATEX Zone 22 Zone 21 Zone 20 2) 2 10 ET 200S S7-400 11 1) Hazardous area Ex e, Ex d Actuators/ sensors 1) ET 200M Actuators/ sensors Ex i, Ex e, Ex d 1) Fieldbus Isolating Transformer DP/PA link 1) PROFIBUS DP ET 200iSP 1) 3) Ex i Actuators/ sensors PROFIBUS PA Actuators/ sensors SITRANS F SITRANS P ET 200 in explosive gas and dust atmospheres 1) Dust atmospheres: installation of components always in an enclosure with IP6x degree of protection. 2) With 10 A DC standard power supply 3) Also complies with FM/UL according to Class I Division 2 The diagram shows the various interfacing possibilities for the distributed I/Os of SIMATIC PCS 7 with consideration of various ambient conditions. 11/2 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Process I/O Introduction Ex I/O modules from the ET 200M range The ET 200M can be run in Ex zone 2/22. The actuators/sensors can be positioned in Ex zone 1/21 when suitable Ex input/output modules are used. Hot swapping of I/O modules within Ex zone 2 is allowed with the right permit (e.g. fire certificate). FM approvals: Class I, Division 2 and Class I, Zone 2. ■ Function Possible online modifications among the process I/Os ET 200M • Adding of ET 200M stations • Adding of I/O modules for the station • Reparameterization of I/O modules • Parameterization of connected HART field devices with SIMATIC PDM ET 200iSP • Adding of ET 200iSP stations • Adding of modules for the station • Reparameterization of modules Integration of actuators/sensors using ET 200iSP ET 200S • Adding of ET 200S stations The ET 200iSP appropriate for gaseous and dusty atmospheres can be installed, according to CENELEC II 2 G (1) GD Eex d e [ib/ia] IIC T4 directly in the Ex zones 1, 2, 21 or 22 as well as in non-hazardous areas. The intrinsically-safe sensors, actuators and HART field devices can also be located in zone 0 or 20 if necessary. PROFIBUS DP, PROFIBUS PA • Adding of PROFIBUS DP stations • Adding of DP/PA links and field devices • Parameterization of field devices with SIMATIC PDM Field devices with PROFIBUS PA capability Using PROFIBUS it is possible to integrate field/process devices directly in Ex zones 1, 2, 21 or 22, and sensors/actuators can also be integrated in zone 0 or 20. FM approvals: Class I, Division 1 and Class I, Zone 0. Intrinsically-safe operator control unit An intrinsically safe PC operator control unit can be used in hazardous areas, zone 1, 2, 21 or 22, if required. For further details on this operator control unit, see Catalog "Add Ons for the SIMATIC PCS 7 Process Control System". 11 Siemens ST PCS 7 · November 2007 11/3 © Siemens AG 2007 Process I/O Central I/O Central I/O modules ■ Overview ■ Selection and Ordering Data Order No. SM 421 Digital Input Modules • 32 inputs, 24 V DC 6ES7 421-1BL01-0AA0 • 32 inputs, 120 V AC/DC 6ES7 421-1EL00-0AA0 • 16 inputs, 24 V DC, with process/diagnostics interrupt 6ES7 421-7BH01-0AB0 • 16 inputs, 24 to 60 V AC/DC, with process/diagnostics interrupt 6ES7 421-7DH00-0AB0 • 16 inputs, 120/230 V AC/DC, inputs according to IEC 1131-2 Type 2 6ES7 421-1FH20-0AA0 SM 422 Digital Output Modules Signal modules from the SIMATIC S7-400 range can be used in the SIMATIC PCS 7 automation system if necessary. These are primarily an alternative to use of distributed I/Os in the case of small applications or systems with a small distributed configuration. 6ES7 422-1BL00-0AA0 • 32 outputs, 24 V DC, 0.5 A; with diagnostics 6ES7 422-7BL00-0AB0 • 16 outputs, 24 V DC; 2 A 6ES7 422-1BH11-0AA0 • 16 outputs; relay contacts 6ES7 422-1HH00-0AA0 • 16 outputs, 120/230 V AC; 2 A 6ES7 422-1FH00-0AA0 SM 431 Analog Input Modules • 16 inputs, non-floating, 13 bit 6ES7 431-0HH00-0AB0 • 8 inputs, floating, 13 bit 6ES7 431-1KF00-0AB0 • 8 inputs, floating, 14 bit, with linearization (RTD/TC) 6ES7 431-1KF10-0AB0 Notes: • 8 inputs, floating, 14 bit 6ES7 431-1KF20-0AB0 Apart from these selected modules it is also possible to use with limitations in functions - all other I/O modules from the current range of S7-400 signal modules. • 16 inputs, floating, 16 bit; process interrupt capability, with diagnostics interrupt 6ES7 431-7QH00-0AB0 All process data from the I/O are available for PCS 7 engineering in the CFC, and can be graphically interconnected to the signal name in the signal list. Diagnostics information is generated automatically when using the I/O modules listed here. • 8 inputs, floating, 16 bit; process interrupt capability, for thermocouples, with diagnostics interrupt 6ES7 431-7KF00-0AB0 • 8 inputs, floating, 16 bit; process interrupt capability, for thermal resistors, with diagnostics interrupt 6ES7 431-7KF10-0AB0 For SIMATIC PCS 7, the I/O modules listed in the Ordering data have been selected from the range of S7-400 signal modules. 11 • 32 outputs; 24 V DC, 0.5 A When using other I/O modules, integration in SIMATIC PCS 7 is limited to the process data, i.e. the full scope of diagnostics functions is not automatically available. These modules can therefore only be used meaningfully in SIMATIC PCS 7 if the diagnostics capability can be omitted. Online modifications and redundancy are not supported by the central I/O. ■ Technical specifications You can find the detailed technical data of the S7-400 modules at the following points: • Catalog ST 70 or • on the Mall/CA 01 under "Industrial automation systems / Controllers / SIMATIC S7" 11/4 Siemens ST PCS 7 · November 2007 SM 432 Analog Output Modules • 8 outputs, floating, 13 bit; for ± 10 V, 0 to 10 V, 1 to 5 V, ± 20 mA, 0 to 20 mA, 4 to 20 mA 6ES7 432-1HF00-0AB0 Front Connector (1 unit) • With screw contacts 6ES7 492-1AL00-0AA0 • With spring clamps 6ES7 492-1BL00-0AA0 • With crimp contacts 6ES7 492-1CL00-0AA0 B) Subject to export regulations: AL: N, ECCN: EAR99H B) © Siemens AG 2007 Process I/O Central I/O Expansion units for central I/O ■ Overview ■ Selection and Ordering Data PS CPU IM 460-x Central controller Expansion units I/O modules, CP and FM IM 461-x Expansion units can be used for the distributed expansion of the SIMATIC S7-400. The IM 460-x interface modules are used as the interface for these expansion units. Restrictions compared to standard I/O modules from the ET 200M range • No redundant interfacing of expansion units • No configuration during normal operation 6ES7 460-3AA01-0AB0 IM 461-3 interface module Corresponding receiver module for the expansion unit 6ES7 461-3AA01-0AA0 UR1 rack for central controllers and expansion units • 18 slots • Suitable for redundant power supply 6ES7 400-1TA01-0AA0 UR2 rack for central controllers and expansion units • 9 slots • Suitable for redundant power supply 6ES7 400-1JA01-0AA0 Accessories Subracks The universal racks (UR) are used for SIMATIC PCS 7. They can be used as central racks and as expansion racks. Other racks: see Catalog ST 70. ■ Selection and Ordering Data Order No. IM 460-3 interface module • Transmitter module for central controller • Without transmission of voltage to the expansion unit • Cable up to 100 m long • With K-bus for communication with CPs and FMs in the expansion unit • For connecting as many as 8 expansion units Order No. IM 460-0 interface module • Transmitter module for central controller • Without transmission of voltage to the expansion unit • Cable up to 5 m long • With K-bus for communication with CPs and FMs in the expansion unit • For connecting as many as 8 expansion units 6ES7 460-0AA01-0AB0 IM 461-0 interface module Corresponding receiver module for the expansion unit 6ES7 461-0AA01-0AA0 IM 460-1 interface module • Transmitter module for central controller • With transmission of the 5 V supply for I/O modules • Cable up to 1.5 m long • Without transmission of the K-bus, hence solely for communication from I/O modules 6ES7 460-1BA01-0AB0 IM 461-1 interface module Corresponding receiver module for the expansion unit 6ES7 461-1BA01-0AA0 468-1 connecting cable for connecting IM 460-0 and IM 461-0; IM 460-3 and IM 461-3 • 0.75 m 6ES7 468-1AH50-0AA0 • 1.5 m 6ES7 468-1BB50-0AA0 •5m 6ES7 468-1BF00-0AA0 Additional lengths for connecting IM 460-3 and IM 461-3 • 10 m 6ES7 468-1CB00-0AA0 • 25 m 6ES7 468-1CC50-0AA0 • 50 m 6ES7 468-1CF00-0AA0 • 100 m 6ES7 468-1DB00-0AA0 Terminator for IM 461-0 6ES7 461-0AA00-7AA0 11 468-3 connecting cable for connecting IM 460-1 and IM 461-1 • 0.75 m 6ES7 468-3AH50-0AA0 • 1.5 m 6ES7 468-3BB50-0AA0 Siemens ST PCS 7 · November 2007 11/5 © Siemens AG 2007 Process I/O SIMATIC PCS 7 MTA terminal module ■ Overview ET 200M redundant ET 200M single MTA MTA Preassembled cable with front connector The terminal modules SIMATIC PCS 7 MTA (Marshaled Termination Assemblies) enable simple, fast and reliable connection of field devices, sensors and actuators to the I/O modules of the ET 200M remote I/O stations. They can be used to significantly reduce the costs and required work for cabling and commissioning, and prevent wiring errors. The individual SIMATIC PCS 7 MTAs are each tailored to specific I/O modules from the ET 200M range (see design for assignment table). MTA versions are available for standard I/O modules as well as for redundant and safety-related I/O modules. The SIMATIC PCS 7 MTAs are connected to the I/O modules using 3 m or 8 m long preassembled cables. 11 ■ Design • SIMATIC PCS 7 MTA in versions for standard, redundant and safety-related I/O modules of the ET 200M distributed I/O system • Redundant 24 V DC supply • 3 or 8 m long preassembled cables for connecting SIMATIC PCS 7 MTA and ET 200M module, in each case with: - 50/25-pole Sub-D socket or 25-pole Sub-D connector, for connection to SIMATIC PCS 7 MTA - 40/20-pole Siemens front connector, female version, for connection to ET 200M module • Screw terminals for the 1:1 connection of field devices, sensors and actuators • Fuse assembly with LED for each input/output channel • Test and release as SIMATIC PCS 7 system component with corresponding approvals (FM, UL, CE, ATEX, TÜV) 11/6 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Process I/O SIMATIC PCS 7 MTA terminal module Product overview with information on combinable ET 200M modules and connection cables MTA type Input/output area. Order No. of MTA 8 channels, AI 1-5V 0/4 - 20 mA 6ES7 650-1AA51-2XX0 6ES7 331-7NF00-0AB0 6ES7 922-3BD00-0AS0 (3 m) (from product version 5) 6ES7 922-3BJ00-0AS0 (8 m) yes 8 channels, AO 4 to 20 mA 6ES7 650-1AB51-2XX0 6ES7 332-5HF00-0AB0 6ES7 922-3BD00-0AS0 (3 m) (from product version 3) 6ES7 922-3BJ00-0AS0 (8 m) yes 6ES7 650-1AF51-2XX0 6ES7 331-7PF10-0AB0 6ES7 922-3BD00-0AS0 (3 m) (from product version 4) 6ES7 922-3BJ00-0AS0 (8 m) and 6ES7 331-7PF11-0AB0 no 8 channels, AI TC Thermocouple types B, C, N, E, R, S, J, L, T, K, U Order No. of ET 200M module Order No. of connecting cable I/O redundancy 8 channels, AI RTD Resistance thermometers 6ES7 650-1AG51-2XX0 Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni200, Ni500, Ni1000, Cu10 16 channels, DO 24 V DC, 0.5 A 6ES7 650-1AD10-2XX0 6ES7 322-8BH01-0AB0 6ES7 922-3BD00-0AT0 (3 m) 6ES7 922-3BJ00-0AT0 (8 m) yes 6 channels F-AI (safety-related) 4 to 20 mA 6ES7 650-1AH51-5XX0 6ES7 336-1HE00-0AB0 6ES7 922-3BD00-0AS0 (3 m) (from product version 6) 6ES7 922-3BJ00-0AS0 (8 m) yes 16 channels, DI 24 V DC 6ES7 650-1AC11-3XX0 6ES7 321-7BH01-0AB0 6ES7 922-3BD00-0AM0 (3 m) (from product version 2) 6ES7 922-3BJ00-0AM0 (8 m) yes 24 channels F-DI (safety-related) 24 V DC 6ES7 650-1AK11-7XX0 6ES7 326-1BK00-0AB0 6ES7 922-3BD00-0AS0 (3 m) and 6ES7 922-3BJ00-0AS0 (8 m) 6ES7 326-1BK01-0AB0 (from product version 1) yes 10 channels F-DO 24 V DC, 2 A (safety-related) 6ES7 650-1AL11-6XX0 6ES7 326-2BF01-0AB0 6ES7 922-3BD00-0AN0 (3 m) (from product version 2) 6ES7 922-3BJ00-0AN0 (8 m) yes 10 channels F-DO 110 - 220 V AC, 5 A; relay (safety24 V DC, 5 A related) 6ES7 650-1AM31-6XX0 6ES7 326-2BF01-0AB0 6ES7 922-3BD00-0AS0 (3 m) (from product version 2) 6ES7 922-3BJ00-0AS0 (8 m) yes ■ Selection and Ordering Data ■ Selection and Ordering Data Order No. SIMATIC PCS 7 MTA SIMATIC PCS 7 MTA AI, 8-channel Terminal module for connection of field devices/sensors to a single or two redundant ET 200M analog input modules 6ES7 331-7NF00-0AB0 Input range: 1 ... 5 V and 0/4 ... 20 mA 6ES7 650-1AA51-2XX0 SIMATIC PCS 7 MTA AO, 8-channel Terminal module for connection of field devices/actuators to a single or two redundant ET 200M analog output modules 6ES7 332-5HF00-0AB0 Output range: 4 ... 20 mA 6ES7 650-1AB51-2XX0 SIMATIC PCS 7 MTA AI TC, 8-channel Terminal module for connection of field devices/sensors to a single ET 200M analog input module 6ES7 331-7PF10-0AB0 or 6ES7 331-7PF11-0AB0 Input range: Thermocouple types B, C, N, E, R, S, J, L, T, K, U 6ES7 650-1AF51-2XX0 6ES7 331-7PF00-0AB0 6ES7 922-3BD00-0AS0 (3 m) (from product version 8) 6ES7 922-3BJ00-0AS0 (8 m) and 6ES7 331-7PF01-0AB0 B) no Order No. SIMATIC PCS 7 MTA AI RTD, 8-channel Terminal module for connection of field devices/sensors to a single ET 200M analog input module 6ES7 331-7PF00-0AB0 or 6ES7 331-7PF01-0AB0 Measuring range: Resistance thermometers Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni200, Ni500, Ni1000, Cu10 6ES7 650-1AG51-2XX0 SIMATIC PCS 7 MTA DO, 16-channel Terminal module for connection of field devices/sensors to a single or two redundant ET 200M digital output modules 6ES7 322-8BH01-0AB0 Output range: 24 V DC, 0.5 A 6ES7650-1AD10-2XX0 11 B) B) Subject to export regulations: AL: N, ECCN: EAR99H Siemens ST PCS 7 · November 2007 11/7 © Siemens AG 2007 Process I/O SIMATIC PCS 7 MTA terminal module ■ Selection and Ordering Data SIMATIC PCS 7 MTA F-AI, 6-channel Terminal module for connection of field devices/sensors to a single or two redundant safety-related ET 200M analog input modules 6ES7 336-1HE00-0AB0 Input range: 4 to 20 mA Accessories included: • One 5.6 V Zener diode board for MTA F-AI, 6-channel, 6ES7 650-1BB51-0XX0 • One 6.2 V Zener diode board for MTA F-AI, 6-channel, 6ES7 650-1BC51-0XX0 • Two FET switch adapters for MTA F-AI, 6-channel, 6ES7 650-1BD51-0XX0 11 Order No. Preassembled cable for connection of ET 200 module and SIMATIC PCS 7 MTA •3m 6ES7 922-3BD00-0AS0 •8m 6ES7 922-3BJ00-0AS0 Connecting cable with 40-pole front connector for ET 200M and 25-pole Sub-D connector for MTA Lengths: 6ES7 650-1AC11-3XX0 SIMATIC PCS 7 MTA F-DI, 24-channel Terminal module for connection of field devices/sensors to a single or two redundant safety-related ET 200M digital input modules 6ES7 326-1BK00-0AB0 or 6ES7 326-1BK01-0AB0 Input range: 24 V DC 6ES7 650-1AK11-7XX0 SIMATIC PCS 7 MTA F-DO, 10-channel Terminal module for connection of field devices/actuators to a single or two redundant safetyrelated ET 200M digital output modules 6ES7 326-2BF01-0AB0 Output range: 24 V DC, 2 A 6ES7 650-1AL11-6XX0 11/8 B) Connecting cable with 40-pole front connector for ET 200M and 50-pole Sub-D connector (female) for MTA Lengths: SIMATIC PCS 7 MTA DI, 16-channel Terminal module for connection of field devices/sensors to a single or two redundant ET 200M digital input modules 6ES7 321-7BH01-0AB0 Input range: 24 V DC SIMATIC PCS 7 MTA F-DO relay, 10-channel Terminal module for connection of field devices/actuators to a single or two redundant safetyrelated ET 200M digital output modules 6ES7 326-2BF01-0AB0 Output range: 110 ... 220 V AC, 5 A; 24 V DC, 5 A Notice: Available with 12/2007 ■ Selection and Ordering Data Order No. 6ES7 650-1AH51-5XX0 •3m 6ES7 922-3BD00-0AT0 •8m 6ES7 922-3BJ00-0AT0 Connecting cable with 40-pole front connector for ET 200M and 25-pole Sub-D connector (female) for MTA Lengths: •3m 6ES7 922-3BD00-0AN0 •8m 6ES7 922-3BJ00-0AN0 Connecting cable with 20-pole front connector for ET 200M and 25-pole Sub-D connector (female) for MTA Lengths: •3m 6ES7 922-3BD00-0AM0 •8m 6ES7 922-3BJ00-0AM0 Accessories Power monitor board (PMB) for display of status of redundant MTA power supply 6ES7 650-1BA01-0XX0 Boards and adapter for SIMATIC PCS 7 MTA F-AI, 6-channel 6ES7 650-1AM31-6XX0 Siemens ST PCS 7 · November 2007 B) • 5.6 V Zener diode board 6ES7 650-1BB51-0XX0 B) • 6.2 V Zener diode board 6ES7 650-1BC51-0XX0 B) • FET switch adapter 6ES7 650-1BD51-0XX0 B) B) Subject to export regulations: AL: N, ECCN: EAR99H © Siemens AG 2007 Process I/O ET 200M distributed I/O Introduction ■ Overview In addition to the standard SIMATIC S7 I/O modules, special I/O modules with diagnostics capability offer the following functions, among others: • Channel-based diagnostics, e.g. open-circuit, short-circuit, limit violations • Internal module monitoring, e.g. parameterization error, RAM error, tripped fuse • Flatter monitoring for sensors • Pulse stretching • Output of a selectable substitute value on failure of the central processing unit In the event of a fault, the modules with diagnostics capability automatically pass on the corresponding message to the operator station, permitting fast and simple troubleshooting. Within the ET 200 range, ET 200M represents the main series of distributed I/O systems for process control applications with SIMATIC PCS 7. The ET 200M has a versatile range of I/O modules of S7-300 design, including ones with special I&C functions. • Standard analog and digital modules • Redundant I/O modules (DI 16 x DC 24 V, with diagnostics capability; DO 32 x DC 24 V/0.5 A; AI 8 x 12 bit) • I/O modules with enhanced diagnostics capability • Ex I/O modules • Controller and counter modules • HART modules • F-modules for safety-related applications When using active bus modules, faulty I/O modules can be replaced while the plant is in operation (RUN) without influencing adjacent modules (hot swapping function). The following actions are possible with the automation system in RUN: • Addition of new modules within a station • Reparameterization of modules • Addition of ET 200M stations The connected HART field devices can be parameterized using SIMATIC PDM. Note: Apart from these selected modules it is also possible to use - with limitations in functions - all other I/O modules from the current range of S7-300 signal modules. ■ Design An ET 200M remote I/O station comprises: • 1 or 2 (redundant) power supply modules (can be omitted in the case of a central 24 V DC supply for the plant) • 1 or 2 (redundant) IM 153 interface modules for connection via PROFIBUS DP with transmission rates of up to 12 Mbit/s • Up to 12 I/O modules for connection of sensors/actuators All I/O modules have optical electrical isolation from the backplane bus. Up to 12 I/O modules can be connected to an IM 153-2 High Feature interface module, or up to 8 to an IM 1532 FO High Feature interface module. The interface modules can also have a redundant design if required. The ET 200M can be used in standard environments and also in Ex zones 2 and 22. The actuators/sensors can be positioned in Ex zones 1 and 21 when suitable Ex input/output modules are used. Hot swapping of I/O modules within Ex zone 2 and 22 is allowed with the right permit (e.g. fire certificate). ■ Technical specifications You can find detailed technical data on the ET 200M and S7-300 I/O modules • in Catalog ST 70 or • in the Mall / Catalog CA 01 under "Industrial automation systems / Controllers / SIMATIC S7" ■ Options SIPLUS extreme range for extended temperature ranges and corrosive environments The "standard" properties of an individual device or system are often insufficient for harsh environmental conditions, applications in corrosive environments or extreme temperature ranges. Depending on the location of use, the result could be limitations in functionality or operational safety or even total failure of the plant. The SIPLUS extreme range offers individually adapted standard products which permit retention of the functionality of your plant or process even under extreme conditions of use. These include: • Ambient temperature range from -25 to +60/+70 °C • Condensation, high humidity • Increased mechanical stress • Extreme loading by media, e.g. toxic atmospheres • Voltage ranges deviating from the standard • Increased degree of protection (dust, water) You can find a summary of the available range of products classified according to their special properties on the Internet. The corresponding SIPLUS product is assigned there to the standard product. Note: SIPLUS products are also included in the Catalog ST 70. Additional information is available in the Internet under: http://www.siemens.com/siplus Siemens ST PCS 7 · November 2007 11/9 11 © Siemens AG 2007 Process I/O ET 200M distributed I/O Power supply ■ Overview ■ Selection and Ordering Data You can use the PS 307 or PS 305 load power supplies as the power supply module for the ET 200M. You can select different input voltages and output currents (120/230 V AC with 2 A, 5 A or 10 A or 24 to 110 V DC with 2 A) depending on the application. With a redundant ET 200M configuration, it is also recommendable to have a redundant 24 V DC supply, e.g. with two PS 307 / PS 305 load power supplies. Order No. PS 307 Load Power Supply Including connection assembly; • 120/230 V AC; 24 V DC - 2 A; 50 mm wide 6ES7 307-1BA00-0AA0 - 5 A; 80 mm wide 6ES7 307-1EA00-0AA0 - 5 A, extended temperature range; 80 mm wide 6ES7 307-1EA80-0AA0 - 10 A, 200 mm wide 6ES7 307-1KA01-0AA0 PS 305 Load Power Supply Including connection assembly; • 24/48/60/110 V DC; 24 V DC - 2 A, extended temperature range; 80 mm wide 11 11/10 Siemens ST PCS 7 · November 2007 6ES7 305-1BA80-0AA0 © Siemens AG 2007 Process I/O ET 200M distributed I/O Interface modules ■ Overview ■ Selection and Ordering Data Order No. IM 153-2 High Feature Slave interface module for connection of an ET 200M to PROFIBUS DP, with time stamp (accuracy 1 ms), support of HART functionality, F modules, FM modules, "Configuration in RUN" function; also for use in redundant systems 6ES7 153-2BA02-0XB0 B) IM 153-2 FO High Feature Slave interface module for connection of an ET 200M to optical PROFIBUS DP; support of HART functionality, F modules, FM modules, "Configuration in RUN" function; also for use in redundant systems 6ES7 153-2BB00-0XB0 B) B) Subject to export regulations: AL: N, ECCN: EAR99H The IM 153-2 High Feature interface module (electrical PROFIBUS DP transmission) or IM 153-2 FO High Feature interface module (optical PROFIBUS DP transmission) is required to connect the ET 200M remote I/O station to the PROFIBUS DP fieldbus. Depending on the fieldbus configuration (single/redundant), the ET 200M remote I/O station can be connected via one single or two redundant interface modules. The IM 153-2 High Feature supports the following functions: 7 HART configuring of intelligent field devices 7 Configuration of ET 200M I/Os in RUN mode of the automation system 7 Connection to redundant AS 412H / AS 414H / AS 417H automation systems 7 Use of ET 200M function modules (controller and counter modules) 7 Operation of up to 12 I/O modules per remote I/O station 7 Time stamping (SOE) with the safety-related SM 326F digital input module (F-DI24) 7 Transmission of additional values with HART secondary variables of the HART SM 331 and SM 332 analog modules (up to 4 per channel or up to 8 per module) 11 On the other hand, the fiber-optic (FO) version IM 153-2 FO High Feature provides the following functions: 7 HART configuring of intelligent field devices 7 Configuration of ET 200M I/Os in RUN mode of the automation system 7 Connection to redundant AS 412H, AS 414H and AS 417H automation systems 7 Use of ET 200M function modules (controller and counter modules) 7 Operation of up to 8 I/O modules per remote I/O station Notes: In order to use the hot swapping function, it is necessary to use the active bus modules and the DIN rail for hot swapping (refer to page 11/12). When using the IM 153-2 FO, additional plastic FOCs and an assembly set for Simplex connectors are required (refer to page 9/40). Siemens ST PCS 7 · November 2007 11/11 © Siemens AG 2007 Process I/O ET 200M distributed I/O ET 200M accessories ■ Overview ■ Selection and Ordering Data Order No. Following components are available as accessories for the ET 200M: • Bus modules for hot swapping • DIN rail for hot swapping • Covers for backplane bus and bus modules • Front connectors • Ex partition for ET 200M • LK 393 cable duct • DM 370 dummy module Bus modules for hot swapping Ex partition Profile rail for hot swapping A mechanical isolation is required between the IM 153 interface module and the first Ex I/O module. For the hot swapping function, an Ex partition is installed which guarantees the prescribed isolation distance between non-intrinsically-safe and intrinsically-safe areas of an ET 200M remote I/O station. • 482 mm long (19 inches) 6ES7 195-1GA00-0XA0 • 530 mm long 6ES7 195-1GF30-0XA0 • 630 mm long 6ES7 195-1GG30-0XA0 • 2000 mm long, for vertical installation 6ES7 195-1GC00-0XA0 Covers Pack with 4 backplane bus covers and 1 bus module cover 6ES7 195-1JA00-0XA0 LK 393 cable duct The LK 393 cable duct provides the prescribed isolation between the load voltage input and the intrinsically safe inputs/outputs. The cable duct is easy to fit following insertion of the load voltage inputs L+. DM 370 dummy module • Reservation of slots for unconfigured I/O modules • Retention of design and address assignment when replacing by I/O module ■ Design Redundant connection Redundant IM 153-2 High Feature 11 ET 200M standard modules Special modules, 80 mm wide, e.g. FM 355 Bus module BM 1x80 Bus module BM 2x40 Singular connection Bus module IM 153/IM 153 IM 153-2 ET 200M High Feature standard modules Bus module PS/IM Bus module BM 2x40 The figure shows use of the various bus modules for hot swapping - at the top for a redundant connection, at the bottom for a non-redundant connection. 11/12 Siemens ST PCS 7 · November 2007 • BM PS/IM for load power supply and IM 153, incl. 1 bus module cover 6ES7 195-7HA00-0XA0 • BM 2x40 for 2 modules, each 40 mm wide 6ES7 195-7HB00-0XA0 • BM 1x80 for 1 module, 80 mm wide 6ES7 195-7HC00-0XA0 • BM IM/IM for two IM 153-2/-2 FOs for design of redundant systems 6ES7 195-7HD10-0XA0 Front connector (1 unit) • 20-pin, with screw contacts 6ES7 392-1AJ00-0AA0 • 20-pin, with spring contacts 6ES7 392-1BJ00-0AA0 • 40-pin, with screw contacts 6ES7 392-1AM00-0AA0 • 40-pin, with spring contacts 6ES7 392-1BM01-0AA0 • 20-pin, FastConnect 6ES7 392-1CJ00-0AA0 B) • 40-pin, FastConnect 6ES7 392-1CM00-0AA0 B) Front connector for Ex analog input module 6ES7 331-7SF00-0AB0 (1 unit) • 20-pin, with screw contacts Enables an accuracy of ± 1.5 °K for the internal cold junction temperature when taking thermocouple temperature measurements in the measuring mode "internal compensation" at ambient temperatures of 0 ... 60 °C 6ES7 392-1AJ20-0AA0 Ex partition for ET 200M • Separation of IM 153 and downstream Ex modules within an ET 200M line • Mixed operation of non-Ex and Ex modules within an ET 200M line • For supporting the hot swapping function in connection with IM 153-2 6ES7 195-1KA00-0XA0 LK 393 cable duct [EEx ib] IIC-conform routing of load voltage cable in front plug, 5 units 6ES7 393-4AA00-0AA0 DM 370 dummy module including bus connector, labeling strips 6ES7 370-0AA01-0AA0 B) Subject to export regulations: AL: N, ECCN: EAR99H © Siemens AG 2007 Process I/O ET 200M distributed I/O Bundles ■ Overview The following preassembled bundles are available for the ET 200M: • I/O subsystem for ET 200M stations with up to 8 I/O modules suitable for hot swapping, comprising: - DIN rail for active bus modules, 482 mm long (19 inches) - PS/IM bus module - PROFIBUS DP IM 153-2 High Feature interface module • I/O subsystem Extended for ET 200M stations with up to 12 I/O modules suitable for hot swapping, comprising: - DIN rail for active bus modules, 630 mm long - PS/IM bus module - PROFIBUS DP IM 153-2 High Feature interface module • IM 153 redundancy bundle for operation of the ET 200M on the AS 412H / AS 414H / AS 417H fault-tolerant automation system, comprising: - 2 PROFIBUS DP IM 153-2 High Feature interface modules - 1 IM/IM active bus module ■ Selection and Ordering Data Order No. I/O subsystem for ET 200M for ET 200M stations with up to 8 I/O modules, suitable for hot swapping, comprising: • DIN rail for active bus modules, 482 mm long (19 inches) • PS/IM bus module • PROFIBUS DP IM 153-2 High Feature interface module 6ES7 654-0XX08-1XA0 B) I/O subsystem extended for ET 200M for ET 200M stations with up to 12 I/O modules, suitable for hot swapping, comprising: • DIN rail for active bus modules, 630 mm long • PS/IM bus module • PROFIBUS DP IM 153-2 High Feature interface module 6ES7 654-0XX08-1XB0 B) IM 153 redundancy bundle for operation of a ET 200M station on the AS 412H, AS 414H or AS 417H fault-tolerant automation system, comprising: • 2 PROFIBUS DP IM 153-2 High Feature interface modules • 1 IM/IM active bus module 6ES7 153-2AR03-0XA0 B) B) Subject to export regulations: AL: N, ECCN: EAR99H 11 Siemens ST PCS 7 · November 2007 11/13 © Siemens AG 2007 Process I/O ET 200M distributed I/O DI - digital input modules ■ Overview ■ Selection and Ordering Data Order No. SM 321 for floating contacts (supply with DC voltage) The digital input modules described here break down into • simple signal modules for direct and alternating voltage, and • modules with diagnostics capability that automatically output a corresponding message to the operator system in the event of a fault. 16 inputs, 24 V DC Redundant design possible (module redundancy) • Electrically isolated in groups of 16 • Front connector required: 20-contact 6ES7 321-1BH02-0AA0 16 inputs, 24 V DC • Electrically isolated in groups of 16; active low • Front connector required: 20-contact 6ES7 321-1BH50-0AA0 16 inputs, 24 V DC, high-speed • Electrically isolated in groups of 16 • 0.05 ms input delay • Front connector required: 20-contact 6ES7 321-1BH10-0AA0 32 inputs, 24 V DC Redundant design possible (module redundancy) • Electrically isolated in groups of 16 • Front connector required: 40-contact 6ES7 321-1BL00-0AA0 16 inputs, 48 to 125 V DC • Electrically isolated in groups of 8 • Front connector required: 20-contact 6ES7 321-1CH20-0AA0 B) SM 321 for floating contacts (supply with DC/AC voltage) 16 inputs, 24 to 48 V AC/DC • Electrically isolated in groups of 1 • Front connector required: 40-contact 6ES7 321-1CH00-0AA0 B) SM 321 for floating contacts (supply with AC voltage) 11 32 inputs, 120 V AC • Electrically isolated in groups of 8 • Front connector required: 40-contact 6ES7 321-1EL00-0AA0 B) 8 inputs, 120/230 V AC Redundant design possible (module redundancy) • Electrically isolated in groups of 2 • Front connector required: 20-contact 6ES7 321-1FF01-0AA0 B) 16 inputs, 120/230 V AC • Electrically isolated in groups of 4 • Front connector required: 20-contact 6ES7 321-1FH00-0AA0 B) B) Subject to export regulations: AL: N, ECCN: EAR99H 11/14 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Process I/O ET 200M distributed I/O DI - digital input modules ■ Selection and Ordering Data ■ Selection and Ordering Data Order No. SM 321 for non-floating contacts (supply with AC voltage) 8 inputs, 120/230 V AC • Electrically isolated in groups of 1 • Front connector required: 40-contact 6ES7 321-1FF10-0AA0 SM 321 modules with diagnostics capability (IM 153-2 High Feature interface module required) for floating contacts (supply with DC voltage) 16 inputs, 24 V DC Redundant design possible (module and channel redundancy) • Electrically isolated in groups of 16 • Time stamping in association with IM 153-2 High Feature, accuracy 5 ms, rising or falling edge, can be parameterized channel-granular • Two short-circuit-proof sensor supplies for 8 channels each • Sensor supply by the module, additional external redundant sensor supply possible • Diagnostics of missing sensor supply for channel group (8 channels) • Diagnostics inside module • Wire break monitoring • Front connector required: 20-contact 6ES7 321-7BH01-0AB0 B) 16 inputs, NAMUR Redundant design possible (module redundancy) • Electrically isolated in groups of 8 • Time stamping in association with IM 153-2 High Feature, accuracy 5 ms, rising or falling edge, can be parameterized channel-granular • Two sensor supplies (8.2 V DC or 18 V DC each) • Connection of NAMUR sensors or contacts with resistor circuit • Pulse stretching • Channel-granular diagnostics (short-circuit, open-circuit, chatter monitoring, discrepancy with changeover contacts) • Diagnostics inside module • Front connector required: 40-contact Order No. 6ES7 321-7TH00-0AB0 B) Subject to export regulations: AL: N, ECCN: EAR99H 11 Siemens ST PCS 7 · November 2007 11/15 © Siemens AG 2007 Process I/O ET 200M distributed I/O DO - digital output modules ■ Overview ■ Selection and Ordering Data Order No. SM 322 for AC voltage (suitable for AC coils, contactors, motor starters, small motors and indicator lights) The digital output modules described here break down into • simple signal modules for DC and AC voltage with different output currents per channel, with a selection of relay modules available for higher output currents and voltages, • modules with diagnostics capability that supply data for troubleshooting and enable parameterizable reactions to a failure of the automation system. ■ Selection and Ordering Data Order No. SM 322 for DC voltage (suitable for solenoid valves, contactors, indicator lights etc.) 11 8 outputs, 24 V DC / 2 A Redundant design possible (module redundancy) • Electrically isolated in groups of 4 • Front connector required: 20-contact 6ES7 322-1BF01-0AA0 16 outputs, 24 V DC / 0.5 A • Electrically isolated in groups of 8 • Front connector required: 20-contact 6ES7 322-1BH01-0AA0 16 outputs, 24 V DC / 0.5 A, high-speed • Electrically isolated in groups of 8 • Output delay max. 0.2 ms • Front connector required: 20-contact 6ES7 322-1BH10-0AA0 32 outputs, 24 V DC / 0.5 A Redundant design possible (module redundancy) • Electrically isolated in groups of 8 • Front connector required: 40-contact 6ES7 322-1BL00-0AA0 8 outputs, 48 to 125 V DC / 1.5 A • Electrically isolated in groups of 4 • Front connector required: 20-contact 6ES7 322-1CF00-0AA0 11/16 8 outputs, 120/230 V AC / 2 A Redundant design possible (module redundancy) • Electrically isolated in groups of 4 • Front connector required: 20-contact 6ES7 322-1FF01-0AA0 B) 16 outputs, 120/230 V AC / 1 A • Electrically isolated in groups of 8 • Front connector required: 20-contact 6ES7 322-1FH00-0AA0 B) 32 outputs, 120/230 V AC / 1 A • Electrically isolated in groups of 8 • Front connector required: 2 x 20-contact 6ES7 322-1FL00-0AA0 B) SM 322 for relay output (suitable for AC/DC solenoid valves, contactors, motor starters, small motors and indicator lights) 8 outputs, 24 to 120 V DC, 48 to 230 V AC, max. 2 A • Electrically isolated in groups of 2 • Front connector required: 20-contact 6ES7 322-1HF01-0AA0 8 outputs, 24 to 120 V DC, 48 to 230 V AC, max. 5 A • Electrically isolated in groups of 1 • Front connector required: 40-contact 6ES7 322-1HF10-0AA0 16 outputs, 24 to 120 V DC, 48 to 230 V AC, max. 2 A • Electrically isolated in groups of 8 • Front connector required: 20-contact 6ES7 322-1HH01-0AA0 B) Subject to export regulations: AL: N, ECCN: EAR99H Siemens ST PCS 7 · November 2007 B) © Siemens AG 2007 Process I/O ET 200M distributed I/O DO - digital output modules ■ Selection and Ordering Data Order No. SM 322 modules with diagnostics capability (with channel and module diagnostics) for DC voltage (suitable for solenoid valves, DC contactors and indicator lights) 8 outputs, 24 V DC / 0.5 A Redundant design possible (module redundancy) • Electrically isolated in groups of 8 • 2 connections per output (with and without series diode) • Connection of a default value by channel in the event of CPU stop (parameterizable) • Wire break monitoring per channel • Load voltage monitoring per channel • Short-circuit monitoring to M/L+ per channel • Module-internal diagnostics functions • Front connector required: 20-contact 6ES7 322-8BF00-0AB0 16 outputs, 24 V DC / 0.5 A Redundant design possible (module and channel redundancy) • Electrically isolated in groups of 4 • Connection of a default value by channel in the event of CPU stop (parameterizable) • Wire break monitoring per channel (with 0 and 1 signals) • Signaling of output overload • Load voltage monitoring or ground monitoring per channel group • Short-circuit monitoring to M/L+ per channel group • Module-internal diagnostics functions • Front connector required: 40-contact 6ES7 322-8BH01-0AB0 ■ Selection and Ordering Data Order No. for AC voltage (suitable for AC coils, contactors, motor starters, small motors and indicator lights) 8 outputs, 120/230 V AC / 2 A • Electrically isolated in groups of 1 • Connection of a default value by channel in the event of CPU stop (parameterizable) • Module-internal diagnostics functions • Front connector required: 40-contact 6ES7 322-5FF00-0AB0 B) 16 outputs, 24/48 V AC/DC / 0.5 A • Electrically isolated in groups of 1 • Connection of a default value by channel in the event of CPU stop (parameterizable) • Module-internal diagnostics functions • Front connector required: 40-contact 6ES7 322-5GH00-0AB0 B) for relay output (suitable for AC/DC coils, contactors, motor starters, small motors and indicator lights) 8 outputs, 24 to 120 V DC, 24 to 230 V AC / max. 5 A • Electrically isolated in groups of 1 • With RC suppressor element for protection of contacts per channel • Connection of a default value by channel in the event of CPU stop (parameterizable) • Module-internal diagnostics functions • Front connector required: 40-contact 6ES7 322-5HF00-0AB0 B) 11 B) Subject to export regulations: AL: N, ECCN: EAR99H Siemens ST PCS 7 · November 2007 11/17 © Siemens AG 2007 Process I/O ET 200M distributed I/O DI/DO - digital input/output modules ■ Overview ■ Selection and Ordering Data Order No. SM 323 for DC voltage (suitable for switches, BERO proximity switches, solenoid valves, contactors, indicator lights etc.) • 8 inputs 24 V DC - Suitable for connection of 2-wire proximity switches (BERO) as sensors • 8 outputs, 24 V DC / 0.5 A • Inputs and outputs electrically isolated in groups of 8 • Front connector required: 20-contact • Standard signal module for DC voltage (24 V DC) with 8 digital inputs and 8 digital outputs • For connection of switches, 2-wire proximity switches (BERO), solenoid valves, contactors, signal lamps 11 11/18 Siemens ST PCS 7 · November 2007 6ES7323-1BH01-0AA0 © Siemens AG 2007 Process I/O ET 200M distributed I/O AI - analog input modules ■ Overview ■ Selection and Ordering Data Order No. SM 331 modules for current, voltage and temperature measurements The analog input modules described here break down into • multi-function modules for current, voltage and temperature measurements, and • special, highly accurate modules for current and voltage measurements or temperature measurements. All modules automatically supply channel-specific and moduleinternal diagnostics data, except module 6ES7 331-1KF010AB0. With the latter module, channel failure is identified by the PCS 7 analog driver block. The individual channels of the analog input modules can be parameterized in groups independently of each other. 8 inputs, individually parameterizable • Resolution 12 bit + sign • Current measurement 0/4 to 20 mA (8 channels; 2 wires with external supply or 4 wires) • Voltage measurement (8 channels) • Resistance thermometer Pt100, Ni100, Ni1000, LG-Ni1000 (8 channels; 2, 3 or 4 wires) • Front connector required: 40-contact 6ES7 331-1KF01-0AB0 8 inputs in 4 channel groups Redundant design possible (module redundancy) • Changeover of measurement type by range module per channel group • Resolution 14 bit + sign • Current measurement 0/4 to 20 mA (8 channels; 2 or 4 wires) • Voltage measurement (8 channels) • Resistance thermometer Pt100, Ni100 (4 channels, 2 or 4 wires) • Thermocouples type E, N, J, K, L (8 channels), internal compensation or external compensation with compensating box or 0 °C cold junction • Wire break monitoring • Diagnostics inside module • Front connector required: 20-contact 6ES7 331-7KF02-0AB0 2 inputs in 1 channel group • Changeover of measurement type by range module • Resolution 14 bit + sign • Current measurement 0/4 to 20 mA (2 channels; 2 or 4 wires) • Voltage measurement (2 channels) • Resistance thermometer Pt100, Ni100 (1 channel, 2 or 4 wires) • Thermocouples type E, N, J, K, L (2 channels), internal compensation or external compensation with compensating box or 0 °C cold junction • Wire break monitoring • Diagnostics inside module • Front connector required: 20-contact 6ES7 331-7KB02-0AB0 B) 11 B) Subject to export regulations: AL: N, ECCN: EAR99H Siemens ST PCS 7 · November 2007 11/19 © Siemens AG 2007 Process I/O ET 200M distributed I/O AI - analog input modules ■ Selection and Ordering Data 11 ■ Selection and Ordering Data Order No. Order No. SM 331 modules for current and voltage measurements SM 331 modules for temperature measurement 8 inputs in 4 channel groups, high-speed • Resolution 13 bit + sign • Measurement type and range selection adjustable per channel group • Current measurement 0/4 to 20 mA (2 or 4 wires) • Voltage measurement • Limit monitoring adjustable for 2 channels • Fast updating of measured value • Supporting of isochronous mode • Diagnostics inside module • Front connector required: 20-contact 6ES7 331-7HF01-0AB0 8 inputs in 4 channel groups • Resolution 15 bit • Resistance thermometer Pt100 ... 1000, Ni100 ... 1000, Cu10 (8 channels; 2, 3 or 4 wires) • Short-circuit-proof • Wire break monitoring • Diagnostics inside module • Front connector required: 40-contact 6ES7 331-7PF01-0AB0 6ES7 331-7PF11-0AB0 8 inputs in 4 channel groups Redundant design possible (module and channel redundancy) • Resolution 15 bit + sign • Current measurement 0/4 to 20 mA (8 channels; 2 or 4 wires) • Voltage measurement (8 channels) • Wire break monitoring • Diagnostics inside module • Front connector required: 40-contact 6ES7 331-7NF00-0AB0 8 inputs in 4 channel groups • Resolution 15 bit • Thermocouples type B, C, N, E, R, S, J, L, T, K, U (8 channels), internal compensation; external compensation with Pt100 through separate inputs possible • Fast module cycle (10 ms for 4 channels) • Short-circuit-proof • Wire break monitoring • Diagnostics inside module • Front connector required: 40-contact 8 inputs in 4 channel groups • Resolution 15 bit + sign • Fast module cycle (min. 10 ms for 4 channels) • Current measurement 0/4 to 20 mA (8 channels; 2 wires with external supply or 4 wires) • Voltage measurement (8 channels) • Wire break monitoring • Short-circuit-proof • Isolation between channel groups • Diagnostics inside module • Front connector required: 40-contact 6ES7 331-7NF10-0AB0 11/20 B) B) Subject to export regulations: AL: N, ECCN: EAR99H Siemens ST PCS 7 · November 2007 B) B) © Siemens AG 2007 Process I/O ET 200M distributed I/O AO - analog output modules ■ Overview ■ Selection and Ordering Data Order No. SM 332 modules for current and voltage outputs The analog output modules for voltage and current described here break down into • modules with 12 bit resolution and various numbers of channels, and • a high-precision module with 15 bit resolution. The analog output modules can be parameterized in groups independently of each other and automatically supply all channelspecific and module-internal diagnostics data. 2 outputs in 2 channel groups • Resolution 12 bit + sign • Voltage 0/1 to 5/10 V; ±10 V (2 channels; 2 or 4 wires) • Current 0/4 to 20 mA; ±20 mA (2 channels; 2 wires) • Parameterizable substitute value output in case of CPU stop • Broken wire monitoring (only for current) • Short circuit monitoring (only for voltage) • Diagnostics inside module • Front connector required: 20-contact 6ES7 332-5HB01-0AB0 4 outputs in 4 channel groups Redundant design possible (module redundancy) • Resolution 12 bit + sign • Voltage 0/1 to 5/10 V; ±10 V (4 channels; 4 wires) • Current 0/4 to 20 mA; ±20 mA (4 channels; 2 wires) • Parameterizable substitute value output in case of CPU stop • Broken wire monitoring (only for current) • Short circuit monitoring (only for voltage) • Diagnostics inside module • Front connector required: 20-contact 6ES7 332-5HD01-0AB0 8 outputs in 8 channel groups Redundant design possible (module and channel redundancy) • Resolution 12 bit + sign • Voltage 0/1 to 5/10 V; ±10 V (8 channels; 4 wires) • Current 0/4 to 20 mA; ±20 mA (8 channels; 2 wires) • Parameterizable substitute value output in case of CPU stop • Broken wire monitoring (only for current) • Short circuit monitoring (only for voltage) • Diagnostics inside module • Front connector required: 40-contact 6ES7 332-5HF00-0AB0 4 outputs in 4 channel groups • Resolution 15 bit + sign • Voltage 0/1 to 5/10 V; ±10 V (4 channels; 4 wires) • Current 0/4 to 20 mA; ±20 mA (4 channels; 2 wires) • Parameterizable substitute value output in case of CPU stop • Isolated by channel • Diagnostics inside module • Front connector required: 20-contact 6ES7 332-7ND02-0AB0 11 B) B) Subject to export regulations: AL: N, ECCN: EAR99H Siemens ST PCS 7 · November 2007 11/21 © Siemens AG 2007 Process I/O ET 200M distributed I/O Ex modules [EEi xb] ■ Overview ■ Selection and Ordering Data 4 outputs, 15 V DC / 20 mA in 4 channel groups • Individually floating channels • Wire break monitoring • Short-circuit monitoring • Diagnostics inside module • Front connector required: 20-contact Order No. 6ES7 322-5RD00-0AB0 Ex analog input module The following analog and digital I/O modules are suitable for use in hazardous plants. They separate the non-intrinsically safe electrical circuits of the automation system and the intrinsically safe electrical circuits of the process. Sensors and actuators suitable for placing in zone 1 or 21 and 2 or 22 hazardous areas as well as intrinsically safe equipment compliant with DIN 50020 and [EEx ib] IIC can be operated on these modules. All Ex modules come with diagnostics capability (channel and module diagnostics). Ex modules identified by "redundant design possible" (6ES7 321-7RD00-0AB0, 6ES7 322-5SD00-0AB0, 6ES7 3317RD00-0AB0, 6ES7 332-5RD00-0AB0) can also be configured redundant when used in non-hazardous plants. ■ Selection and Ordering Data Order No. Ex digital input module 11 4 NAMUR inputs in 4 channel groups Redundant design possible (module redundancy) • Voltage supply to sensors 8.2 V • Individually floating channels • Wire break and short-circuit monitoring (directly at the contact for contacts with external resistor circuit) • Diagnostics inside module • Front connector required: 20-contact 6ES7 321-7RD00-0AB0 6ES7 331-7RD00-0AB0 8 inputs in 4 channel groups • Resolution 15 bit + sign • Thermocouples type T, U, E, J, L, K, N, R, S, B (8 channels) Internal compensation; external compensation with Pt100 (2 channels), compensating box or 0/50 °C cold junction • Resistance thermometer Pt100, Pt200, Ni100 (4 channels; 2-wire or 4-wire, 3-wire Pt100 on request) • Wire break monitoring • Diagnostics inside module • Front connector required: 20-contact Note: A special front connector for the Ex analog input module 6ES7 331-7SF00-0AB0 enables greater accuracy when taking thermocouple temperature measurements in "internal compensation" mode (see page 11/12). 6ES7 331-7SF00-0AB0 Ex analog output module Ex digital output module 4 outputs, 24 V DC / 10 mA in 4 channel groups Redundant design possible (module redundancy) • Individually floating channels • Wire break monitoring • Short-circuit monitoring • Diagnostics inside module • Front connector required: 20-contact 4 inputs, 0/4 to 20 mA in 4 channel groups Redundant design possible (module redundancy) • Individually floating channels • Resolution 15 bit + sign • Connection of 2-wire or 4-wire transmitters possible • Wire break monitoring • Measurement range monitoring • Short-circuit-proof • Diagnostics inside module • Front connector required: 20-contact 6ES7 322-5SD00-0AB0 4 outputs, 0/4 to 20 mA in 4 channel groups Redundant design possible (module redundancy) • Individually floating channels • Resolution 15 bit • For 2-wire transmitters • Wire break monitoring • Diagnostics inside module • Front connector required: 20-contact 6ES7 332-5RD00-0AB0 For additional Ex modules, refer to page 11/23. 11/22 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Process I/O ET 200M distributed I/O Modules with HART ■ Overview ■ Function HART is a serial transmission procedure with which additional parameter data such as measuring ranges, attenuation etc. can be sent to transmitters and actuators over a 4 to 20-mA current loop. The HART jobs for each channel can be remotely initiated over the PROFIBUS DP. This usually takes place from the central engineering system of the SIMATIC PCS 7 process control system per SIMATIC PDM. The modules with HART (Highway Addressable Remote Transducer) which can be used in ET 200M remote I/O stations (with IM 153-2 High Feature interface module) permit connection of HART devices to SIMATIC PCS 7 automation systems. All transmitters or HART actuators certified for digital communication using the HART protocol can be connected via these modules. Conventional transmitters with 4 to 20 mA technology without HART protocol can also be connected. All modules with HART come with diagnostics capability (channel and module diagnostics). The diagnostics and monitoring functions are directly available in SIMATIC PCS 7. They require no additional engineering. Plain text messages output on the operator station provide information on faults or changes in the HART parameter settings. Homogenous integration in the SIMATIC Process Device Manager (PDM) and the PCS 7 Asset Management permit intuitive online diagnostics and parameterization of all connected field devices from a central position. The modules with HART have the following features: • Connections compatible with the conventional analog modules of the ET 200M • Additional communications possibility over the current loop • 8 analog channels per module (2 analog channels with Ex modules) • Each channel is a primary master of the HART protocol • Selectable input range per channel (AI): - 0 to 20 mA (without HART function) - ± 20 mA (without HART function, not with Ex module) - 4 to 20 mA (with/without HART function) • Selectable output range per channel (AO): - 0 to 20 mA (with/without HART function; in the case of Ex module, only without HART function) - 4 to 20 mA (with/without HART function) Additional functions of the HART analog modules 6ES7 331-7TF01-0AB0 and 6ES7 332-8TF01-0AB0: • Supplementary HART variables (up to 4 per channel, up to 8 per module) allow the transmission of additional values from/to the HART devices • Modules can be operated in redundant mode (module and channel redundancy) Parameterization • For the analog input modules (AI), it is possible to parameterize e.g. conversion time, input range, limits, alarms, smoothing of measured values • For the analog output modules (AO), it is possible to parameterize e.g. output range, response on stoppage of AS (CPU), diagnostics • Remote parameterization (per PROFIBUS DP) of the HART transmitters and actuators with SIMATIC PDM • It is still possible to parameterize the HART devices using an operator terminal (handheld). Siemens ST PCS 7 · November 2007 11/23 11 © Siemens AG 2007 Process I/O ET 200M distributed I/O Modules with HART ■ Technical specifications You can find the detailed technical data of the modules with HART at the following points: • Catalog IK PI (Catalog Section "Distributed I/Os") or • on the Mall/CA 01 under "Distributed I/Os / ET 200M" 11 ■ Selection and Ordering Data Order No. SM 331 HART analog input module Redundant design possible (module and channel redundancy) 8 inputs, 0/4 to 20 mA or ±20 mA • Resolution: 15 bit + sign • Connection of 2-wire or 4-wire transmitters possible • HART (2-wire or 4-wire) • Wire break monitoring • Short-circuit-proof • Front connector required: 20-contact 6ES7 331-7TF01-0AB0 B) SM 332 HART analog output module Redundant design possible (module and channel redundancy) 8 outputs, 0/4 to 20 mA • Resolution: 15 bit + sign • For 2-wire actuators • HART (2-wire) • Wire break monitoring • Front connector required: 20-contact 6ES7 332-8TF01-0AB0 B) Ex analog input module with HART [EEx ib] 2 inputs, 0/4 to 20 mA in 2 channel groups • Individually floating channels • Resolution: 15 bit + sign • Connection of 2-wire or 4-wire transmitters possible • Wire break monitoring • Short-circuit-proof • HART (2-wire or 4-wire) • Front connector required: 20-contact 6ES7 331-7TB00-0AB0 B) Ex analog output module with HART [EEx ib] 2 outputs, 0/4 to 20 mA in 2 channel groups • Individually floating channels • Resolution: 12 bit + sign • For 2-wire actuators • Wire break monitoring • HART • Front connector required: 20-contact 6ES7 332-5TB00-0AB0 B) B) Subject to export regulations: AL: N, ECCN: EAR99H 11/24 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Process I/O ET 200M distributed I/O F modules ■ Overview ■ Selection and Ordering Data Order No. SM 326F failsafe digital input module for floating contacts The safety functions of the AS 414F/FH and AS 417F/FH automation systems are matched to the safety-related I/O modules (F-modules) of the ET 200M distributed I/O system. The F-signal modules (DI/DO/AI) in the ET 200M remote I/O stations are able to guarantee plant safety even in the event of a CPU failure. They are of redundant design, and can diagnose both internal and external faults. They carry out self-tests for this purpose, e.g. for short-circuit or wire breakage, and automatically monitor the discrepancy time defined in the parameter settings. They comply with the requirements up to SIL 3 (IEC 61508) or AK 6 (VDE 0801). The input modules operate internally with single-channel evaluation (SIL 2 sensors), 2-out-of-2 evaluation (SIL 3 sensors) or 2-out-of-3 channel evaluation (only F-AI module). A safety response is triggered immediately there are any differences. The type of evaluation influences the number of usable inputs (channels). For example, only half of the existing inputs are available in the case of 2-out-of-2 channel evaluation. The digital output modules enable safe disconnection through a second disconnect path in the event of a faulty output. 24 inputs, 24 V DC Electrically isolated in groups of 12 Redundant design possible (module redundancy) • 4 short-circuit-proof sensor power supplies, each for 6 channels, isolated in groups of 3 • External sensor power supply possible • SIL 2: single-channel evaluation, 24 channels • SIL 3: 2-out-of-2 evaluation on the module, 12 channels (adjustable discrepancy time) • Short-circuit monitoring to L+ • Discrepancy monitoring • Supports time stamping (SOE) • Diagnostics inside module • PROFIsafe telegram • Front connector required: 40-contact 6ES7 326-1BK01-0AB0 8 inputs, NAMUR [EEx ib] Isolated by channel Redundant design possible (module redundancy) • 8 short-circuit-resistant sensor power supplies, each for 1 channel, mutually isolated • SIL 2: single-channel evaluation, 8 channels • SIL 3: 2-out-of-2 evaluation on the module, 4 channels (adjustable discrepancy time) • Wire break and short-circuit monitoring (for contacts with external resistor circuit) • Discrepancy monitoring • Diagnostics inside module • PROFIsafe telegram • Front connector required: 40-contact 6ES7 326-1RF00-0AB0 Siemens ST PCS 7 · November 2007 11 11/25 © Siemens AG 2007 Process I/O ET 200M distributed I/O F modules ■ Selection and Ordering Data Order No. ■ Options SM 326F failsafe digital output, suitable for solenoid valves, DC contactors and signal lamps 10 outputs, 24 V DC, 2 A Electrically isolated in groups of 5 (outputs with internal diode) Redundant design possible (module and channel redundancy) • SIL 2, SIL 3 parameterizable (10 channels) • P/P-switching (for non-floating loads; ground and earth connected together) • Wire break and short-circuit monitoring • Diagnostics inside module • PROFIsafe telegram • Front connector required: 40-contact 6ES7 326-2BF01-0AB0 8 outputs, 24 V DC, 2 A Electrically isolated in groups of 4 • SIL 2, SIL 3 parameterizable (8 channels) • P/M-switching (for floating loads; ground and earth separate) • Wire break and short-circuit monitoring • Diagnostics inside module • PROFIsafe telegram • Front connector required: 40-contact 6ES7 326-2BF40-0AB0 11 PROFIBUS copper connection Isolating bus submodule for active backplane bus IM 153-2 ET 200 rack PROFIBUS copper connection or fiber-optic cable Isolating module for isolation of standard and F-modules Isolating module 6ES7 336-1HE00-0AB0 The following components are available as accessories for the F modules: • Isolating module - For isolation of F and standard modules in an ET 200M remote I/O station - For signal isolation when using a copper bus connection (only F modules in an ET 200M remote I/O station with IM 153-2) • Isolating bus submodule for isolating module, when using an active backplane bus Note: The isolating module for F modules and the isolating bus submodule can only be used together. The 40-mm wide gap cannot be used for other modules. Options Isolating module For F modules, 40 mm wide • For isolation of F and standard modules in an ET 200M rack • For signal isolation when using a copper bus connection (only F modules in a rack with IM 153-2) 6ES7 195-7KF00-0XA0 Isolating bus module 80 mm wide, for isolating module, when using an active backplane bus 6ES7 195-7HG00-0XA0 11/26 F-modules IM 153-2 ET 200 rack only for SIL 3 operation, SIL 2 also possible without isolating module SM 336F failsafe analog input module 6 inputs, 4 to 20 mA Redundant design possible (module redundancy) • Resolution 13 bit + sign • Isolated from the backplane bus • 2-wire or 4-wire connection • SIL 2: two-channel evaluation, 6 sensors • SIL 3: two-channel evaluation, 12 sensors (adjustable tolerance window) • Wire break monitoring • Tolerance monitoring between 2 sensors (SIL 3) • Diagnostics inside module • PROFIsafe telegram • Front connector required: 40-contact Isolating module Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Process I/O ET 200M distributed I/O Closed-loop control modules ■ Overview The FM 355 is an intelligent 4-channel controller module for universal control tasks. It can be used to control temperature, pressure and flow. The following versions of the FM 355 are available: • FM 355 C Continuous-action controller with 4 analog outputs for controlling analog actuators • FM 355 S Step or pulse controller with 8 digital outputs for controlling motor-driven (integrating) actuators or binary controlled actuators (e.g. electrical heating strips and cartridges) • FM 355-2 C/S Specially optimized for temperature controls with user-friendly online self-optimization integrated ■ Function The FM 355 / FM 355-2 modules have four separate control channels. These controllers have the following features: • Predefined controller structures for - fixed-setpoint control, - cascade control, - ratio control, - 3-component control • Various operating modes: - automatic mode, - manual mode, - safety mode, - follow-up mode, - backup mode • Sampling interval (dependent on the resolution of the analog inputs and the compensation input): - at 12 bit: 20 ms to 100 ms (only FM 355-2) - at 14 bit: 100 ms to 500 ms (dependent on the number of enabled analog inputs) • 2 control algorithms: - self-optimized temperature control algorithm, - PID algorithm • Integrated online self-optimization without configuration (only FM 355-2) - for faster adoption of the operating point • User-friendly controller optimization • Backup mode: The controller can maintain its control function in the event of CPU failure or CPU stop. Programmable safety setpoint values or safety manipulated variables are set for this purpose. • Feedforward control: The analog inputs can be optionally used for feedforward control as well as for actual value acquisition. 11 Siemens ST PCS 7 · November 2007 11/27 © Siemens AG 2007 Process I/O ET 200M distributed I/O Closed-loop control modules ■ Integration ■ Selection and Ordering Data Automation system OP FM-355 module (80 mm wide) IM 153-2 ET 200 Rack Standard modules Use in SIMATIC PCS 7 The FM 355 / FM 355-2 modules can be used to implement control tasks outside the SIMATIC PCS 7 automation system. The modules have not only controller structures but also analog and digital channels, thus eliminating the need for additional modules to detect the setpoint/actual value or to control the actuator. On the one hand this reduces the work load for the CPU, on the other hand it enables backup mode with which the control system continues to work even if the CPU fails. In this case the FM 355 module can be operated further with an OP operator panel (does not apply to FM 355-2). 11 The operator panel is connected to the PROFIBUS DP fieldbus for this purpose. The CPU of the automation system can surrender input privilege to the operator panel in normal operation as well. The parameters that can be accessed with the operator panel are the setpoint and manipulated variable. If the FM 355 module is operated from the operator panel, the automation system reads back the values accessible from the operator panel after the input privilege is withdrawn or recovered again. Bumpless continuation of the operations is thus assured. IM 153-2 High Feature interface modules are needed for the PROFIBUS DP connection when the FM 355 / FM 355-2 controller modules are used in ET 200M. PCS 7 blocks CFC blocks with OS faceplates for all FM 355 modules are included in the scope of supply of the standard SIMATIC PCS 7 library (part of engineering software). These blocks are integrated into the PCS 7 driver concept. This guarantees homogenous system integration (including automatic diagnostics messages). Parameterization in HW-Config A configuration package containing all parameterization masks required for configuring, parameterizing and commissioning is included in the scope of supply of the FM 355 controller modules. 11/28 Siemens ST PCS 7 · November 2007 Order No. FM 355 C controller module With 4 analog outputs for 4 continuous-action controllers Required front connector: 2 x 20-pin Incl. multi-lingual configuration package, manual and Getting Started (German, English, French, Italian) on CD-ROM 6ES7 355-0VH10-0AE0 FM 355 S controller module With 8 digital outputs for 4 step or pulse controllers Required front connector: 2 x 20-pin Incl. multi-lingual configuration package, manual and Getting Started (German, English, French, Italian) on CD-ROM 6ES7 355-1VH10-0AE0 FM 355-2 C temperature controller module With 4 analog outputs for 4 continuous-action controllers Required front connector: 2 x 20-pin Incl. multi-lingual configuration package, manual and Getting Started (German, English, French, Italian) on CD-ROM 6ES7 355-2CH00-0AE0 FM 355-2 S temperature controller module With 8 digital outputs for 4 step or pulse controllers Required front connector: 2 x 20-pin Incl. multi-lingual configuration package, manual and Getting Started (German, English, French, Italian) on CD-ROM 6ES7 355-2SH00-0AE0 Note: In the case of the FM 355 C and FM 355 S controller modules, the channels are not electrically isolated from one another © Siemens AG 2007 Process I/O ET 200M distributed I/O Counter modules ■ Overview The FM 350-1 counter module is a single-channel intelligent counter module for simple counting tasks, suitable for the direct connection of incremental encoders. It provides a comparison function with 2 preselectable reference values, as well as integrated digital outputs for outputting a reaction upon reaching the reference value. ■ Selection and Ordering Data Order No. FM 350-1 counter module Counting functions up to 500 kHz 1 channel for the connection of 5 V and 24 V incremental encoders Required front connector: 1 x 20-pin incl. configuration package on CD-ROM 6ES7 350-1AH03-0AE0 FM 350-2 counter module 8 channels with max. 20 kHz counting frequency; for 24 V encoders, for the following tasks: counting, frequency measurement, speed measurement, period measurement, dosing Required front connector: 1 x 40-pin incl. configuration package on CD-ROM 6ES7 350-2AH00-0AE0 The FM 350-2 counter module is an eight-channel intelligent counter module for universal counting and measuring tasks, as well as for simple positioning jobs (max. 4 axes). 11 Siemens ST PCS 7 · November 2007 11/29 © Siemens AG 2007 Process I/O ET 200iSP distributed I/O Introduction ■ Overview ■ Design The ET 200iSP is a modular, intrinsically-safe I/O system in IP30 degree of protection, and can be configured with up to 32 electronics modules (4/8-channel). The range of electronics modules covers: • 8-channel digital input module DI, can also be used as counter or frequency meter • 4-channel digital output module DO with external actuator switch-off via High or Low signal (H/L switch-off) • 4-channel analog input modules AI for temperature measurements with resistance thermometer or thermocouple • 4-channel analog input modules AI for connection of 2/4-wire transmitters with or without HART functionality • 4-channel analog output module AO for connection of field devices with or without HART functionality The ET 200iSP suitable for gas and dust atmospheres according to the ATEX directive 94/9/EU can be installed directly in the Ex zones 1, 2, 21 or 22 as well as in non-hazardous areas. The intrinsically-safe sensors, actuators and HART field devices can also be located in zone 0 or 20 if necessary. 11 The ET 200iSP consists of the following components: • Carrier system with terminal modules for prewiring, and also for inserting power supply, interface and electronics modules, mounted on an S7-300 rail • 1 or 2 (redundant) power supply modules PS with pressurized enclosure • 1 or 2 (redundant) IM 152 interface modules for PROFIBUS DP • Up to 32 electronics modules (4/8-channel) in any combination, including watchdog module • Terminating module (included in scope of delivery of terminal modules for the PROFIBUS interface) Assembly is quick and easy: • Latching of terminal modules onto the S7-300 rail • Prewiring of process signal cables on the terminal modules using spring-loaded or screw-type connections • Plugging-in of power supply, interface and electronics modules without the need for additional tools The maximum number of electronics modules which can be used per station may be limited depending on the current consumption of the modules required to solve the automation task. However, up to 16 electronics modules can be used without limitation. If the ET 200iSP is used in a hazardous area, it must be installed in an appropriate Ex housing which at least corresponds to the IP54 degree of protection. Appropriate versions of an IP65 housing are offered in the Section "Stainless steel wall housings". Exceptional features of the ET 200iSP architecture • Installation and testing of the wiring is possible in advance without the electronics module • Isolation of the mechanical and electronic systems, in conjunction with the independent process wiring, permits fast and easy replacement of the electronics modules • Mechanical coding which is carried out when an electronics module is plugged onto a terminal module for the first time prevents the connection of incorrect replacement modules • Hot swapping of the power supply modules and electronics modules is possible without a fire certificate 11/30 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Process I/O ET 200iSP distributed I/O Introduction ■ Integration Distributed ET 200iSP stations are connected to the SIMATIC PCS 7 automation systems (controllers) via the PROFIBUS DP, which can be routed intrinsically-safe into Ex zone 1 using an isolating transformer (RS485-iS coupler) as barrier. Data transfer rates of up to 1.5 Mbit/s are possible. The modern architecture with independent wiring and automatic slot coding supports simple and reliable hot swapping of individual modules without a fire certificate. To increase plant availability, both the power supply and the PROFIBUS DP interface can be of redundant design. The ET 200iSP is integrated into SIMATIC PCS 7 using standard driver blocks. You can therefore configure and parameterize the ET 200iSP in the SIMATIC Manager of the engineering system extremely simply using HW Config. The system function CiR (Configuration in Run) is also supported, and permits the following changes to be made to the configuration during runtime: • Adding of an ET 200iSP station • Adding of a module in an ET 200iSP station • Reparameterization of modules. Vendor-specific information and maintenance data are saved powerfail-proof on the electronics modules. The existing standard diagnostics drivers preprocess the diagnostics messages generated by internal or external faults (e.g. wire breakage or short-circuit) as well as status messages of the connected HART field devices for the host operator system and the maintenance station of the PCS 7 asset management. The ET 200iSP and the HART field devices can also be parameterized using SIMATIC PDM (process device manager). With SIMATIC PDM you can directly access the HART field devices on the ET 200iSP by routing via PROFIBUS DP. ■ Technical specifications Degree of protection IP30 Ambient temperature -20 ... +70 °C Loading of media According to ISA-S71.04 severity level G1; G2; G3 (except for NH3, only level G2 in this case) EMC Electromagnetic compatibility according to NE21 Vibration resistance 0.5 g continuously, 1 g occasionally Approvals, standards • ATEX II 2 G (1) GD I M2 Ex de [ia/ib] IIC T4 Ex de [ia/ib] I • IECEx Zone 1 Ex de [ia/ib] IIC T4 • cFMus Class I,II,II NI Division 2, Groups A, B, C, D, E, F, G T4 AIS Division 1, Groups A, B, C, D, E, F, G Class I Zone 1, AEx de [ia/ib] IIC T4 Class I,II,II Division 2, Groups A, B, C, D, E, F, G T4 providing int. safe circuits for Division 1, Groups A, B, C, D, E, F, G Class I Zone 1, AEx de [ia/ib] IIC T4 • cULus • PROFIBUS EN 50170, Volume 2 • IEC IEC 61131, Part 2 • CE According to 94/9/EU (ATEX 100a), 89/336/EEC and 73/23/EEC • Shipbuilding approval Classification companies • ABS (American Bureau of Shipping) • BV (Bureau Veritas) • DNV (Det Norske Veritas) • GL (Germanischer Lloyd) • LRS (Lloyds Register of Shipping) • Class NK (Nippon Kaiji Kyokai) For detailed technical specifications, especially on individual components such as power supply module, interface module or electronics modules, see: • Catalog IK PI • Mall/CA 01 under "Distributed I/Os / ET 200iSP" Siemens ST PCS 7 · November 2007 11/31 11 © Siemens AG 2007 Process I/O ET 200iSP distributed I/O ET 200iSP power supply unit ■ Overview ■ Design Depending on the operating mode (standard or redundant), one or two power supply modules are plugged onto the corresponding terminal modules. Hot swapping is also possible in the hazardous area. The operating status of the power supply modules is displayed on two LEDs on the IM 152 interface module (one for each module). The 24 V DC supply for the station is provided via EX e terminals on the terminal module of the power supply unit. This connection must not be removed in the hazardous area. The feeding power supply must be installed in the non-hazardous area. The ET 200iSP must be terminated on the right-hand side (following the last electronics module) by a terminating module. The terminating module is included in the scope of delivery of the IM 152. ET 200iSP power supply unit is the designation for the combination of one (standard) or two redundant power supply modules PS with the matching terminal module: • Standard: TM-PS-A terminal module • Redundancy: TM-PS-B terminal module (additionally) Power supply modules and terminal modules must each be ordered separately. Functions of the power supply modules • They provide the ET 200iSP with the safely isolated operating voltages for - logic (via the backplane bus), - PROFIBUS DP interface (IM 152-1), - power bus (for powering the electronics modules). • They handle the safety-related limitation of the output voltage. • They have a pressurized metal enclosure (explosion protection EEx d). • They can be operated in redundant mode. 11 11/32 Siemens ST PCS 7 · November 2007 ■ Selection and Ordering Data Order No. Power supply module PS for ET 200iSP 6ES7 138-7EA01-0AA0 TM-PS-A terminal module for standard operation 6ES7 193-7DA10-0AA0 B) TM-PS-B terminal module for redundant operation 6ES7 193-7DB10-0AA0 B) B) Subject to export regulations: AL: N, ECCN: EAR99H © Siemens AG 2007 Process I/O ET 200iSP distributed I/O IM 152-1 interface module ■ Overview ■ Design The terminal module of the IM 152 (TM-IM/EM or TM-IM/IM) is connected directly next to the power supply unit on the DIN rail. The PROFIBUS DP connection of the IM 152 is made using the standard Sub-D socket on the terminal module. The matching connection element we provide is a special terminating plug with selectable terminating resistance. The terminating resistance must be activated on the last ET 200iSP station of each PROFIBUS DP segment. Hot swapping of the IM 152 and the PROFIBUS connector is permissible under hazardous conditions. A terminating module is provided together with the IM 152, and must be fitted at the right end of each ET 200iSP station following the last electronics module. The IM 152 has a slot for micro memory cards (MMC). The firmware can therefore be updated either via the PROFIBUS DP or using MMCs. The IM 152 interface module connects the ET 200iSP to the PROFIBUS DP with intrinsically-safe RS 485-iS transmission technology with transmission rates up to 1.5 Mbit/s. A redundant connection is also possible. In this case the ET 200iSP is connected via two interface modules to two redundant PROFIBUS DP segments of a fault-tolerant automation system. The IM 152 is plugged onto a special terminal module (to be ordered separately). The following terminal modules are available: • TM-IM/EM60 terminal module for one interface module and one electronics module (with screw-type or spring-loaded terminals) • TM-IM/IM terminal module for two interface modules (for redundant PROFIBUS DP connection) The PROFIBUS addresses can be set using DIL switches at the front which are protected by a cover. LEDs on the front of the IM 152 signal the supply voltage, group faults, bus faults, the active IM with redundant operation, and the operating state of the fitted power supply modules. ■ Selection and Ordering Data IM 152-1 interface module for ET 200iSP incl. terminating module Order No. 6ES7 152-1AA00-0AB0 TM-IM/EM60 terminal module for ET 200iSP for one IM 152 module and one electronics module Tasks of the IM 152 interface module • Connection of ET 200iSP to the intrinsically-safe PROFIBUS DP • Autonomous communication with the host automation system • Preparation of data for the fitted electronic modules • Saving of parameters of the electronics modules • The IM 152 can assign a 20-ms time stamp to digital process signals. • TM-IM/EM60S (screw-type terminals) 6ES7 193-7AA00-0AA0 B) • TM-IM/EM60S (spring-loaded terminals) 6ES7 193-7AA10-0AA0 B) TM-IM/IM terminal module for ET 200iSP for two IM 152 modules (redundant operation) 6ES7 193-7AB00-0AA0 The maximum address space of the interface module is 244 bytes for inputs, and 244 bytes for outputs. PROFIBUS connector with selectable terminating resistor for connection of IM 152 to PROFIBUS DP with RS 485-iS transmission technology 6ES7 972-0DA60-0XA0 RS 485-IS coupler Isolating transformer for connection of PROFIBUS DP segments with RS 485 and RS 485-iS transmission technologies 6ES7 972-0AC80-0XA0 Accessories B) S7-300 rails • 585 mm long, suitable for assembly of ET 200iSP in a 650-mm wide wall housing 6ES7 390-1AF85-0AA0 • 885 mm long, suitable for assembly of ET 200iSP in a 950-mm wide wall housing 6ES7 390-1AJ85-0AA0 B) Subject to export regulations: AL: N, ECCN: EAR99H For further accessories such as labeling strips or plates, see Catalog IK PI or the A&D Mall/CA 01 under "ET 200iSP distributed I/O". Siemens ST PCS 7 · November 2007 11/33 11 © Siemens AG 2007 Process I/O ET 200iSP distributed I/O Electronics modules and watchdog module ■ Overview ■ Design Electronics modules The current range of electronics modules covers: • 8-channel digital input module DI NAMUR, can also be used as counter or frequency meter • 4-channel digital output module DO with external actuator switch-off via High or Low signal (H/L switch-off) • 4-channel analog input modules AI for temperature measurements with resistance thermometer (RTD) or thermocouple (TC) • 4-channel analog input modules AI for connection of 2/4-wire transmitters with or without HART functionality • 4-channel analog output module AO for connection of field devices with or without HART functionality A TC sensor module for internal temperature compensation is provided with the 4 AI TC module, and is fitted on the corresponding terminals of the associated terminal module. External compensation is possible for the 4 AI RTD module by connecting a Pt100. 11 The DO modules have a switch-off function which is triggered by an external signal (High or Low) from a switch-off device in the hazardous area. This permits implementation of an external switch-off independent of the automation system (controller). It is also possible to combine several DO modules into a switch-off group for this purpose. The intrinsically-safe power supply for the switch-off device is either via the watchdog module or a separate intrinsically-safe source. Watchdog module The watchdog module has two fundamental functions: • Monitoring of the ET 200iSP remote I/O station for hardware failures (hardware lifebeat); external, applicative failure monitoring is also possible via an I/O address area of the module • Intrinsically-safe power supply for external actuator switch-off The watchdog module must be plugged onto a terminal module (order separately). The first slot directly next to the interface module is provided for the watchdog module. You can use the same terminal modules for the watchdog module as for the electronics modules. 11/34 Siemens ST PCS 7 · November 2007 • The electronics modules are plugged as planned onto the corresponding terminal modules using screw-type systems (TM-EM/EM60S) or spring-loaded systems (TM-EM/EM60C). The terminal modules must be ordered in addition. • The mechanical coding of the terminal module which is carried out when an electronics module is plugged on for the first time prevents the connection of incorrect replacement modules. • Hot swapping of individual modules is possible under hazardous conditions. • The process signals are connected to the terminals of the terminal modules assigned according to the plan, using either conventional screw-type or spring-loaded systems (conductor cross-sections 0.14 to max. 2.5 mm²) depending on the type of module. • All electronics modules are implemented in the EEx i "intrinsically safe" degree of protection and can be easily replaced under hazardous conditions (hot swapping). • Using a spare module plugged onto a terminal module for electronics modules (TM-EM/EM60S/ TM-EM/EM60C), you can reserve a slot for any electronics modules or close a gap resulting from the design. The spare module can be simply replaced by the electronics module at a later point in time. © Siemens AG 2007 Process I/O ET 200iSP distributed I/O Electronics modules and watchdog module ■ Selection and Ordering Data ■ Selection and Ordering Data Order No. Digital electronics modules Digital input modules 8 DI NAMUR For evaluation of NAMUR sensors, connected/non-connected contacts, as well as for recording counter pulses or measuring frequencies • 8 x NAMUR (NAMUR sensor on/off, NAMUR changeover contact) or connected/ non-connected inputs (single/changeover contact) • 2 channels optionally usable as counters (max. 5 kHz) or frequency meters (1 Hz ... 5 kHz) • Time tagging 5 ms, rising or falling edge • Wire break monitoring • Short-circuit monitoring • Sensor power supply monitoring • Flutter monitoring 6ES7 131-7RF00-0AB0 B) Digital output module with H switch-off (external actuator switch-off via H-signal); for switching of solenoid valves, DC relays, signal lamps, actuators 4 DO DC 23.1 V/20 mA • 4 channels with 20 mA each • Short-circuit monitoring • Wire break monitoring • Parameterizable connection of substitute value in case of CPU failure • Load-free switching of outputs via external intrinsically-safe signal 6ES7 132-7RD01-0AB0 4 DO DC 17.4 V/27 mA • 4 channels with 27 mA each or • 2 outputs connected in parallel with 54 mA each • Short-circuit monitoring • Wire break monitoring • Parameterizable connection of substitute value in case of CPU failure • Load-free switching of outputs via external intrinsically-safe signal 6ES7 132-7RD11-0AB0 4 DO DC 17.4 V/40 mA • 4 channels with 40 mA each or • 2 outputs connected in parallel with 80 mA each • Short-circuit monitoring • Wire break monitoring • Parameterizable connection of substitute value in case of CPU failure • Load-free switching of outputs via external intrinsically-safe signal 6ES7 132-7RD21-0AB0 B) Order No. Digital output module with L switch-off (external actuator switch-off via L-signal); for switching of solenoid valves, DC relays, signal lamps, actuators 4 DO DC 23.1 V/20 mA • 4 channels with 20 mA each • Short-circuit monitoring • Wire break monitoring • Parameterizable connection of substitute value in case of CPU failure • Load-free switching of outputs via external intrinsically-safe signal 6ES7 132-7GD00-0AB0 4 DO DC 17.4 V/27 mA • 4 channels with 27 mA each or • 2 outputs connected in parallel with 54 mA each • Short-circuit monitoring • Wire break monitoring • Parameterizable connection of substitute value in case of CPU failure • Load-free switching of outputs via external intrinsically-safe signal 6ES7 132-7GD10-0AB0 4 DO DC 17.4 V/40 mA • 4 channels with 40 mA each or • 2 outputs connected in parallel with 80 mA each • Short-circuit monitoring • Wire break monitoring • Parameterizable connection of substitute value in case of CPU failure • Load-free switching of outputs via external intrinsically-safe signal 6ES7 132-7GD20-0AB0 B) 11 B) Subject to export regulations: AL: N, ECCN: EAR99H Siemens ST PCS 7 · November 2007 11/35 © Siemens AG 2007 Process I/O ET 200iSP distributed I/O Electronics modules and watchdog module ■ Selection and Ordering Data ■ Selection and Ordering Data Order No. Analog input modules 11 4 AI I 2 WIRE HART For measuring currents with 2-wire transmitters with/without HART functionality • 4 x 4 ... 20 mA, HART, 2-wire transmitter • Transmitter load: max. 750 Ω • Resolution 12 bit + sign • Short-circuit monitoring • Wire break monitoring 6ES7 134-7TD00-0AB0 4 AI I 4 WIRE HART For measuring currents with 4-wire transmitters with/without HART functionality • 4 x 0/4 ... 20 mA, HART, 4-wire transmitter • Transmitter load: max. 750 Ω • Resolution 12 bit + sign • Wire break monitoring 6ES7 134-7TD50-0AB0 4 AI RTD For measuring resistances as well as for temperature measurements with resistance thermometers • 4 x RTD, resistance thermometer Pt100/Ni100 • 2-, 3-, 4-wire • Resolution 15 bit + sign • Short-circuit monitoring • Wire break monitoring 6ES7 134-7SD50-0AB0 4 AI TC For measuring thermal e.m.f. as well as for temperature measurements with thermocouples • 4 x TC (thermocouples) • Type B [PtRh-PtRh] • Type N [NiCrSi-NiSi] • Type E [NiCr-CuNi] • Type R [PtRh-Pt] • Type S [PtPh-Pt] • Type J [Fe-CuNi] • Type L [Fe-CuNi] • Type T [Cu-CuNi] • Type K [NiCr-Ni] • Type U [Cu-CuNi] • Resolution 15 bit + sign • Internal temperature compensation possible using TC sensor module (included in scope of delivery of module) • External temperature compensation via PT100 connected to RTD module of same ET 200iSP station • Wire break monitoring 6ES7 134-7SD00-0AB0 11/36 Order No. Analog output modules Analog electronics modules B) 4 AO I HART For output of currents to field devices with/without HART functionality • 4 x 0/4 ... 20 mA, HART (max. load 750 Ω) • Resolution 14 bit • Short-circuit monitoring • Wire break monitoring • Parameterizable substitute value in case of CPU failure 6ES7 135-7TD00-0AB0 B) Watchdog module For failure monitoring and for the intrinsically-safe power supply of an external actuator switch-off 6ES7 138-7BB00-0AB0 B) TM-EM/EM60S terminal module for ET 200iSP For two electronics modules, screw terminals 6ES7 193-7CA00-0AA0 B) TM-EM/EM60C terminal module for ET 200iSP For two electronics modules, spring-loaded terminals 6ES7 193-7CA10-0AA0 B) 6ES7 138-7AA00-0AA0 B) Terminal modules Accessories Reserve module For any electronics module S7-300 rail Siemens ST PCS 7 · November 2007 • 585 mm long, suitable for assembly of ET 200iSP in a 650-mm wide wall housing 6ES7 390-1AF85-0AA0 • 885 mm long, suitable for assembly of ET 200iSP in a 950-mm wide wall housing 6ES7 390-1AJ85-0AA0 B) Subject to export regulations: AL: N, ECCN: EAR99H For further accessories such as labeling strips or plates, see Catalog IK PI or the A&D Mall/CA 01 under "ET 200iSP distributed I/O". © Siemens AG 2007 Process I/O ET 200iSP distributed I/O RS 485-IS coupler ■ Overview ■ Selection and Ordering Data RS 485-IS coupler Isolating transformer for connection of PROFIBUS DP segments with RS 485 and RS 485-iS transmission technologies Order No. 6ES7 972-0AC80-0XA0 Accessories PROFIBUS connector with selectable terminating resistor For connection of IM 152 to PROFIBUS DP with RS 485-iS transmission technology 6ES7 972-0DA60-0XA0 B) S7-300 rails Lengths: Tasks of the RS 485-iS coupler • Conversion of the electrical PROFIBUS DP RS 485 transmission technology into the intrinsically-safe RS 485-iS transmission technology with a transmission rate of 1.5 Mbit/s • Required to connect intrinsically-safe PROFIBUS DP stations, e.g. ET 200iSP, ET 200iS or devices from other vendors with Ex i DP connection • Functionality as a safety barrier • Additional use as a repeater in the hazardous area • Passive bus station (no configuration necessary) • Certified according to ATEX 100a • 160 mm 6ES7 390-1AB60-0AA0 • 482 mm 6ES7 390-1AE80-0AA0 • 530 mm 6ES7 390-1AF30-0AA0 • 830 mm 6ES7 390-1AJ30-0AA0 • 2000 mm 6ES7 390-1BC00-0AA0 PROFIBUS Fast Connect bus cable Standard type with special design for fast mounting, 2-core, shielded, cut-to-length; max. delivery unit 1000 m, minimum ordering quantity 20 m 6XV1 830-0EH10 B) Subject to export regulations: AL: N, ECCN: EAR99H ■ Design • The RS 485-iS coupler is an open unit; assembly is only permissible in housings, cabinets or rooms for electrical equipment. • The RS 485-iS coupler is approved for use in hazardous areas of zone 2. It must be fitted in a housing which at least corresponds to the IP54 degree of protection. A manufacturer’s declaration for zone 2 (according to EN 50021) is required for the housing and the necessary cable glands. • The RS 485-iS coupler can be used in a horizontal or vertical position. • Installation is on a SIMATIC S7-300 rail. • Diagnostics LEDs on the front panel signal the operating status. 11 Connection to PROFIBUS DP • Connection to standard PROFIBUS DP via standard Sub-D socket (at the bottom on the RS 485-iS coupler, behind the right front door). Integral bus connection for PROFIBUS DP with RS 485-iS transmission technology • Connection of PROFIBUS DP with RS 485-iS transmission technology via screw terminals (at the top of the RS 485-iS coupler, behind the right front door) • The last bus station on the intrinsically-safe PROFIBUS DP segment (not further RS 485-iS couplers) must be terminated by a selectable resistance using the connector, Order No. 6ES7 972-0DA60-0XA0. Siemens ST PCS 7 · November 2007 11/37 © Siemens AG 2007 Process I/O ET 200iSP distributed I/O Stainless steel wall enclosure ■ Design ■ Selection and Ordering Data Order No. • Wall housing 950 x 450 x 230, for installation of max. 25 ET 200iSP modules, for use in dusty area, with 3 rows of M16 cable glands (total 68) and 2 rows of blanking plugs 6DL2 804-0DE30 • Wall housing 950 x 450 x 230, for installation of max. 25 ET 200iSP modules, for use in dusty area, with 5 rows of M16 cable glands (total 111) 6DL2 804-0DE50 Housing with installation of ET 200iSP modules, for use in gaseous area, IP65 (IP54 when using an air-conditioning nozzle) 1) ET 200iSP modules can also be installed in stainless steel wall housings designed to meet more exacting protection requirements. The housings are available in three different sizes. They comply with degree of protection IP65 and can also be used in Ex zone 1. ■ Selection and Ordering Data Order No. Stainless steel housing IP65 for Ex zone 1 in protection class EEx e Empty housing without installation of modules, for use in gaseous area, IP65 11 • Wall housing 650 x 450 x 230, for installation of max. 15 ET 200iSP modules, for use in gaseous area, with 3 rows of M16 cable glands (total 41) and 2 rows of blanking plugs 6DL2 804-0AD30 • Wall housing 650 x 450 x 230, for installation of max. 15 ET 200iSP modules, for use in gaseous area, with 5 rows of M16 cable glands (total 66) 6DL2 804-0AD50 • Wall housing 950 x 450 x 230, for installation of max. 25 ET 200iSP modules, for use in gaseous area, with 3 rows of M16 cable glands (total 68) and 2 rows of blanking plugs 6DL2 804-0AE30 • Wall housing 950 x 450 x 230, for installation of max. 25 ET 200iSP modules, for use in gaseous area, with 5 rows of M16 cable glands (total 111) 6DL2 804-0AE50 Empty housing without installation of modules, for use in dusty area, IP65 • Wall housing 650 x 450 x 230, for installation of max. 15 ET 200iSP modules, for use in dusty area, with 3 rows of M16 cable glands (total 41) and 2 rows of blanking plugs 6DL2 804-0DD30 • Wall housing 650 x 450 x 230, for installation of max. 15 ET 200iSP modules, for use in dusty area, with 5 rows of M16 cable glands (total 66) 6DL2 804-0DD50 11/38 • Wall housing 650 x 450 x 230, for installation of max. 15 ET 200iSP modules, for use in gaseous area, with 3 rows of M16 cable glands (total 41) and 2 rows of blanking plugs 6DL2 804-1AD30 • Wall housing 650 x 450 x 230, for installation of max. 15 ET 200iSP modules, for use in gaseous area, with 5 rows of M16 cable glands (total 66) 6DL2 804-1AD50 • Wall housing 950 x 450 x 230, for installation of max. 25 ET 200iSP modules, for use in gaseous area, with 3 rows of M16 cable glands (total 68) and 2 rows of blanking plugs 6DL2 804-1AE30 • Wall housing 950 x 450 x 230, for installation of max. 25 ET 200iSP modules, for use in gaseous area, with 5 rows of M16 cable glands (total 111) 6DL2 804-1AE50 Housing with installation of modules, for use in dusty area, IP65 1) • Wall housing 650 x 450 x 230, for installation of max. 15 ET 200iSP modules, for use in dusty area, with 3 rows of M16 cable glands (total 41) and 2 rows of blanking plugs 6DL2 804-1DD30 • Wall housing 650 x 450 x 230, for installation of max. 15 ET 200iSP modules, for use in dusty area, with 5 rows of M16 cable glands (total 66) 6DL2 804-1DD50 • Wall housing 950 x 450 x 230, for installation of max. 25 ET 200iSP modules, for use in dusty area, with 3 rows of M16 cable glands (total 68) and 2 rows of blanking plugs 6DL2 804-1DE30 • Wall housing 950 x 450 x 230, for installation of max. 25 ET 200iSP modules, for use in dusty area, with 5 rows of M16 cable glands (total 111) 6DL2 804-1DE50 1) Siemens ST PCS 7 · November 2007 The ET 200iSP components have to be ordered separately © Siemens AG 2007 Process I/O ET 200S distributed I/O Introduction ■ Overview The ET 200S is a bit-modular distributed I/O system in IP 20 degree of protection and is approved for operation in Ex zone 2 or 22 (except for operation with motor starters). It is designed with independent wiring that supports the hot swapping of I/O modules (with fire certificate). The range of I/Os that can be used with SIMATIC PCS 7 includes power modules for electronics modules and motor starters, analog and digital signal modules, and motor starters up to 7.5 kW. The implementation of safety engineering applications is supported by: • Safety-related F-components which are integrated in the SIMATIC Safety Integrated System, e.g. terminal, power and electronics modules as well as motor starters • SIGUARD safety engineering for motor starter applications with conventional safety logic in plants of safety categories 2 to 4 (EN 954-1) Note: In addition to the selected modules, all other current ET 200S electronics modules can be used, but with limited functionality. Use of components from the SIPLUS extreme range in extended temperature ranges and under medial loading on request. ■ Design Main components of the ET 200S distributed I/O system: • Terminal modules enable the electrical and mechanical connection of the I/O modules and carry the terminals for the process wiring: - TM-P terminal modules for power modules - TM-E terminal modules for electronics modules - TM-DS/TM-RS terminal modules for motor starters and TM-xB expansion modules • IM 151 interface module for connecting the PROFIBUS DP to the ET 200S station. The terminal module is included in the scope of delivery. • Power modules for PM-E electronics modules and PM-D motor starters - Individual grouping of load and sensor supply voltages and their monitoring, as well as for the safe shutting down of digital output modules - Supplying and monitoring the auxiliary voltages for motor starters, as well as for the shutting down of a complete group of motor starters • Electronics modules for process data exchange - Digital electronics modules for connecting digital sensors and actuators - Analog electronics modules for connecting analog sensors and actuators • Motor starter modules for switching and protecting any three-phase loads • Accessories - Reserve module for reserving a slot for any electronics module - Label sheets for printing ID labels on a laser printer - Shield connection: shield connecting element, shield terminal, ground terminal, copper voltage bus 3 x 10 mm; components for the low-impedance connection of cable shielding at low cost of installation Siemens ST PCS 7 · November 2007 11/39 11 © Siemens AG 2007 Process I/O ET 200S distributed I/O Introduction Mounting The terminal modules that can be mounted on a DIN rail (35 x 15 x 7.5 or 15 mm) form the carrier system for the I/O modules. They are used for the process wiring and enable the electrical and mechanical connection of the I/O modules. The terminal modules can be prewired and tested without the I/O modules. The I/O modules are simply plugged in place later. Terminal modules are available with screw connections, spring-loaded terminals or FastConnect design for fast mounting. The automatic coding of the I/O modules reliably prevents the risk of injury to persons and/or destruction of modules through accidental mounting of the wrong module. Expansion limits Depending on the IM 151 interface module used, the expansion of an ET 200S station is subject to the following limits: • A maximum total of 63 I/O modules per station can be inserted between interface module and terminating module • The maximum permissible width of an ET 200S station is 2 m • The maximum address volume of all the inserted I/O modules is 244 byte for input data and 244 byte for output data • The maximum number of parameters is restricted to 244 byte per station ET 200S configuration The SIMATIC ET 200 configurator can be used to compile an ET 200S station rapidly and simply. It knows the configuration rules, and supports selection of all components and associated accessories in interactive mode. The SIMATIC ET 200 is available in the current CD-ROM Catalog CA 01 and on the Internet. Additional information is available in the Internet under: http://www.siemens.com/et200 11 11/40 Siemens ST PCS 7 · November 2007 ■ ATechnical specifications Detailed technical data on the ET 200S can be found • in the IK PI catalog or • in the Mall / CA 01 at "Distributed I/Os / ET 200S“ © Siemens AG 2007 Process I/O ET 200S distributed I/O Terminal modules ■ Overview ■ Selection and Ordering Data Order No. Terminal Modules TM-P for Power Modules • Terminal modules are mechanical modules for integrating the power and electronics modules as well as the motor starters and expansion modules (Ordering data of the terminal modules for motor starters and expansion modules can be found under "Motor starters") • For constructing the independent wiring using self-assembling voltage buses • Alternatively with screw-type or spring-loaded terminals and Fast Connect design • Replaceable terminal box • Automatic coding of the electronics modules • Build-as-you-go shielding of the backplane bus for high data security • Optional plug-in shield connection • Color coding facility for the terminals and for identifying the slot numbers TM-P15S23-A1 Terminal Module 2 x 3 terminals, terminal access to AUX1 bus, AUX1 interconnected to the left, screw-type terminals Ordering unit 1 piece 6ES7 193-4CC20-0AA0 TM-P15C23-A1 Terminal Module 2 x 3 terminals, terminal access to AUX1 bus, AUX1 interconnected to the left, spring-type terminals Ordering unit 1 piece 6ES7 193-4CC30-0AA0 TM-P15N23-A1 Terminal Module 2 x 3 terminals, terminal access to AUX1 bus, AUX1 interconnected to the left, Fast Connect Ordering unit 1 piece 6ES7 193-4CC70-0AA0 TM-P15S23-A0 Terminal Module 2 x 3 terminals, terminal access to AUX1 bus, AUX1 interrupted to the left, screw-type terminals Ordering unit 1 piece 6ES7 193-4CD20-0AA0 TM-P15C23-A0 Terminal Module 2 x 3 terminals, terminal access to AUX1 bus, AUX1 interrupted to the left, spring-type terminals Ordering unit 1 piece 6ES7 193-4CD30-0AA0 TM-P15N23-A0 Terminal Module 2 x 3 terminals, terminal access to AUX1 bus, AUX1 interrupted to the left, Fast Connect Ordering unit 1 piece 6ES7 193-4CD70-0AA0 TM-P15S22-01 Terminal Module 2 x 2 terminals, no terminal access to AUX1 bus, AUX1 interconnected to the left, screw-type terminals Ordering unit 1 piece 6ES7 193-4CE00-0AA0 TM-P15C22-01 Terminal Module 2 x 2 terminals, no terminal access to AUX1 bus, AUX1 interconnected to the left, springloaded terminals Ordering unit 1 piece 6ES7 193-4CE10-0AA0 TM-P15N22-01 Terminal Module 2 x 2 terminals, no terminal access to AUX1 bus, AUX1 interconnected to the left, Fast Connect Ordering unit 1 piece 6ES7 193-4CE60-0AA0 TM-P30S44-A0 Terminal Module 7 x 2 terminals, terminal access to AUX1 bus, AUX1 interrupted to the left, screw-type terminals for PM-E F PROFIsafe Ordering unit 1 piece 6ES7 193-4CK20-0AA0 TM-P30C44-A0 Terminal Module 7 x 2 terminals, terminal access to AUX1 bus, AUX1 interrupted to the left, spring-loaded terminals for PM-E F PROFIsafe Ordering unit 1 piece 6ES7 193-4CK30-0AA0 11 Siemens ST PCS 7 · November 2007 11/41 © Siemens AG 2007 Process I/O ET 200S distributed I/O Terminal modules ■ Selection and Ordering Data Order No. TM-E Terminal Modules for Electronic Modules 11 ■ Selection and Ordering Data Order No. TM-E30S44-01 Terminal Module 4 x 4 terminals, no terminal access to AUX1 bus, AUX1 interconnected to the left, screw-type terminals Ordering unit 1 piece 6ES7 193-4CG20-0AA0 TM-E30C44-01 Terminal Module 4 x 4 terminals, no terminal access to AUX1 bus, AUX1 interconnected to the left, springloaded terminals Ordering unit 1 piece 6ES7 193-4CG30-0AA0 TM-E15S24-A1 Terminal Module 2 x 4 terminals, terminal access to AUX1 bus, AUX1 interconnected to the left, screw-type terminals Ordering unit 5 pieces 6ES7 193-4CA20-0AA0 TM-E15C24-A1 Terminal Module 2 x 4 terminals, terminal access to AUX1 bus, AUX1 interconnected to the left, spring-type terminals Ordering unit 5 pieces 6ES7 193-4CA30-0AA0 TM-E15N24-A1 Terminal Module 2 x 4 terminals, terminal access to AUX1 bus, AUX1 interconnected to the left, Fast Connect Ordering unit 5 pieces 6ES7 193-4CA70-0AA0 TM-E30S46-A1 Terminal Module 4 x 6 terminals, terminal access to AUX1 bus, AUX1 interconnected to the left, screw-type terminals Ordering unit 1 piece 6ES7 193-4CF40-0AA0 TM-E15S24-01 Terminal Module 2 x 4 terminals, no terminal access to AUX1 bus, AUX1 interconnected to the left, screw-type terminals Ordering unit 5 pieces 6ES7 193-4CB20-0AA0 TM-E30C46-A1 Terminal Module 4 x 6 terminals, terminal access to AUX1 bus, AUX1 interconnected to the left, spring-type terminals Ordering unit 1 piece 6ES7 193-4CF50-0AA0 TM-E15C24-01 Terminal Module 2 x 4 terminals, no terminal access to AUX1 bus, AUX1 interconnected to the left, springloaded terminals Ordering unit 5 pieces 6ES7 193-4CB30-0AA0 TM-E15S24-AT Terminal Module For internal temperature compensation with 2AI TC High Feature, screw-type terminals Ordering unit 1 piece 6ES7 193-4CL20-0AA0 6ES7 193-4CB70-0AA0 TM-E15C24-AT Terminal Module For internal temperature compensation with 2AI TC High Feature, spring-loaded terminals Ordering unit 1 piece 6ES7 193-4CL30-0AA0 TM-E15N24-01 Terminal Module 2 x 4 terminals, no terminal access to AUX1 bus, AUX1 interconnected to the left, Fast Connect Ordering unit 5 pieces TM-E15S23-01 Terminal Module 2 x 3 terminals, no terminal access to AUX1 bus, AUX1 interconnected to the left, screw-type terminals Ordering unit 5 pieces 6ES7 193-4CB00-0AA0 TM-E15C23-01 Terminal Module 2 x 3 terminals, no terminal access to AUX1 bus, AUX1 interconnected to the left, springloaded terminals Ordering unit 5 pieces 6ES7 193-4CB10-0AA0 TM-E15N23-01 Terminal Module 2 x 3 terminals, no terminal access to AUX1 bus, AUX1 interconnected to the left, Fast Connect Ordering unit 5 pieces 6ES7 193-4CB60-0AA0 TM-E15N26-A1 Terminal Module 2 x 6 terminals, terminal access to AUX1 bus, AUX1 interconnected to the left, Fast Connect Ordering unit 5 pieces 6ES7 193-4CA80-0AA0 TM-E15S26-A1 Terminal Module 2 x 6 terminals, terminal access to AUX1 bus, AUX1 interconnected to the left, screw-type terminals Ordering unit 5 pieces 6ES7 193-4CA40-0AA0 TM-E15C26-A1 Terminal Module 2 x 6 terminals, terminal access to AUX1 bus, AUX1 interconnected to the left, spring-type terminals Ordering unit 5 pieces 6ES7 193-4CA50-0AA0 11/42 Siemens ST PCS 7 · November 2007 Accessories for the terminal modules, see the IK PI catalog or A&D Mall / CA 01 at "Distributed I/Os / ET 200S" © Siemens AG 2007 Process I/O ET 200S distributed I/O Interface modules ■ Overview ■ Selection and Ordering Data IM151-1 interface module for ET 200S, High Feature Order No. 6ES7 151-1BA02-0AB0 B) B) Subject to export regulations: AL: N, ECCN: EAR99H • IM 151-1 high feature (RS 485) • Interface module for electrical connection of the ET 200S to PROFIBUS DP using copper bus cables • Handles all data exchange with the PROFIBUS DP master 11 Siemens ST PCS 7 · November 2007 11/43 © Siemens AG 2007 Process I/O ET 200S distributed I/O Power modules The TM-P terminal module of the power module interrupts the voltage buses (P1/P2) and therefore opens up a new potential group. All sensor and load supplies of the downstream electronics modules are fed from the TM-P and monitored by the power module. The total current of all modules of a potential group is limited by the maximum current carrying capacity of the power module (up to 10 A depending on the voltage and temperature range; for details, refer to the technical specifications of the power modules in Catalog IK PI). ■ Overview Possible combinations of the TM-P terminal modules and PM-E power modules TM-P terminal modules for power modules Screw-type terminal 6ES7 193-... 15S23-A1 15S23-A0 15S22-01 30S44-A0 ...4CC20 0AA0 ...4CD20 0AA0 ...4CE000AA0 ...4CK200AA0 Spring terminal TMTMTMTMP15C23-A1 P15C23-A0 P15C22-01 P30C44-A0 6ES7 193-... ...4CC30 ...4CD30 ...4CE10...4CK300AA0 0AA0 0AA0 0AA0 PM-E power modules • For all types of electronic modules (including safety-oriented electronic modules); limitations resulting from power supply with PM-E DC 24 V • For monitoring and, depending on the version, fusing the voltage to electronic modules provided via the TM-P terminal module (load and sensor supply voltage) • Diagnostics message for voltage and blown fuse (can be switched off per configuration) • Two versions with different supply voltages: - PM-E DC 24 V (not for 2 DI AC 120 V, 2 DI AC 230 V and 2 DO AC 24 to 230 V) - PM-E DC 24 to 48 V; AC 24 to 230 V; with additional fuse 11 PM-E F power modules • For all non-safety-oriented types of electronic modules with 24 V DC supply • For monitoring the voltage to electronic modules provided via the TM-P terminal module (load and sensor supply voltage) • For safe switching off of series-connected standard digital output modules 24 V DC (up to 10 A) via relay contacts (up to Cat. 3 according to EN 954 or SIL 2 according to IEC 61508): - 2 DO / 0.5 A standard, 6ES7 132-4BB01-0AA0 - 2 DO / 2 A standard, 6ES7 132-4BB31-0AA0 - 2 DO / 0.5 A high feature, 6ES7 132-4BB01-0AB0 - 2 DO / 2 A high feature, 6ES7 132-4BB31-0AB0 - 4 DO / 0.5 A standard, 6ES7 132-4BD01-0AA0 - 4 DO / 2 A standard, 6ES7 132-4BD31-0AA0 • Two versions: - PM-E F pm DC 24 V PROFIsafe for ungrounded loads (separate ground and earth); with two additional safety-oriented digital outputs (p/m switching, up to Cat. 4 / SIL 3) - PM-E F pp DC 24 V PROFIsafe for grounded loads (ground and earth connected), e.g. actuators for connection to a central ground ■ Design Depending on the possible combinations listed in the table, the power modules are plugged onto corresponding TM-P terminal modules. Power modules are suitable for dividing the ET 200S into potential groups. A power module must be provided at the beginning of each potential group. In addition, the first module following the IM 151-1 High Feature interface module must always be a power module. Fast Connect 6ES7 193-... TMTMTMP15N23-A1 P15N23-A0 P15N22-01 ...4CC70 0AA0 ...4CD70 0AA0 ...4CE600AA0 • • • • • • Power modules PM-E DC 24 V PM-E DC 24 ... 48 V/ AC 24 ... 230 V PM-E F DC 24 V PROFIsafe • PM-D F DC 24 V PROFIsafe • ■ Selection and Ordering Data Order No. Power module PM-E for electronics modules Power module PM-E • 24 V DC / 10 A - Monitoring of the load voltage 6ES7 138-4CA01-0AA0 B) • 24 ... 48 V DC; 24 ... 230 V AC - Monitoring of the fuse - Monitoring of the load voltage 6ES7 138-4CB11-0AB0 B) • PM-E F pm DC 24 V PROFIsafe - 1 x relay 24 V DC/10 A, P/M-switching, for switchingoff series-connected standard digital output modules (up to AK 4, SIL 2) - 2 x 24 V DC/2 A, P/M-switching, with wire breakage monitoring by channel (with "1" signal) - Safe monitoring of communication with PROFIsafe - Diagnostics inside module - Overload diagnostics by channel 6ES7 138-4CF02-0AB0 B) • PM-E F pp DC 24 V PROFIsafe - 1 x relay 24 V DC/10 A, P/P-switching, for switching-off series-connected standard digital output modules (up to AK 4, SIL 2) - Safe monitoring of communication with PROFIsafe - Diagnostics inside module - Overload diagnostics by channel 6ES7 138-4CF41-0AB0 B) Power module PM-E F B) Subject to export regulations: AL: N, ECCN: EAR99H 11/44 Siemens ST PCS 7 · November 2007 -- © Siemens AG 2007 Process I/O ET 200S distributed I/O Digital electronics modules ■ Overview • 2- and 4-channel digital inputs and outputs for the ET 200S • Can be plugged onto TM-E terminal modules with automatic coding. • High-feature versions for enhanced plant availability, additional functions and comprehensive diagnostics • Hot swapping of modules possible • Safety-related digital input module 4/8 F-DI PROFIsafe • Safety-related digital output module 4 F-DO PROFIsafe 24 V DC/2 A • Isolated from the backplane bus ■ Design Possible combinations of the TM-E terminal modules and digital modules TM-E terminal modules for electronics modules Screw-type terminal Order No. 6ES7 193... TM-E15S26A1 …4CA400AA0 TM-E15S24A1 …4CA200AA0 TM-E15S2401 …4CB200AA0 TM-E15S2301 …4CB000AA0 TM-E15S24AT …4CL20-0AA0 TM-E30S4401 …4CG200AA0 TM-E30S46A1 …4CF40-0AA0 Spring terminal Order No. 6ES7 193... TM-E15C26A1 …4CA500AA0 TM-E15C24A1 …4CA300AA0 TM-E15C2401 …4CB300AA0 TM-E15C2301 …4CB100AA0 TM-E15C24AT …4CL30-0AA0 TM-E30C4401 …4CG300AA0 TM-E30C46A1 …4CF50-0AA0 Fast Connect Order No. 6ES7 193... TM-E15N26A1 …4CA800AA0 TM-E15N24A1 …4CA700AA0 TM-E15N2401 …4CB700AA0 TM-E15N2301 …4CB600AA0 -- -- -- 2DI 24 V DC Standard 2DI 24 V DC High Feature 4DI 24 V DC Standard 4DI 24 V DC High Feature • • • • 4DI 24 … 48 V AC/DC High Feature • • • • 4 DI NAMUR • • • • • • • • • • • • • • • • 2 DO 24 V DC/2 A Standard 2 DO 24 V DC/2 A High Feature 4 DO 24 V DC/2 A Standard • • • • 2 DO 24 … 230 V AC/2 A • • • • • • • • Electronics modules 2DI 120 V AC Standard 2DI 230 V AC Standard 2 DO 24 V DC/0.5 A Standard 2 DO 24 V DC/0.5 A High Feature 4 DO 24 V DC/0.5 A Standard 2RO, 24 … 120 V DC/5 A, 24 … 230 V AC/5 A 2RO, 24 … 48 V DC/5 A, 24 … 230 V AC/5 A 11 4/8 failsafe DI 24 V DC1) 4 failsafe DO 24 V DC/2 A1) Reserve (width 15 mm) • • • • • Reserve (width 30 mm) 1) • • • • • • See Manual "ET 200S failsafe modules" in the documentation packages "S7 F Systems" and "S7 Distributed Safety" Siemens ST PCS 7 · November 2007 11/45 © Siemens AG 2007 Process I/O ET 200S distributed I/O Digital electronics modules ■ Selection and Ordering Data ■ Selection and Ordering Data Order No. Digital inputs for floating contacts 6ES7 132-4BB31-0AB0 DO 4 x 24 V DC/0.5 A, standard Ordering unit 5 items 6ES7 132-4BD01-0AA0 DO 4 x 24 V DC/2 A, standard Ordering unit 5 items 6ES7 132-4BD32-0AA0 B) DI 2 x 24 V DC, standard Ordering unit 5 items 6ES7 131-4BB01-0AA0 B) DI 4 x 24 V DC, standard Ordering unit 5 items 6ES7 131-4BD01-0AA0 B) DI 2 x 24 V DC, High Feature; with diagnostics • Short-circuit monitoring Ordering unit 5 items 6ES7 131-4BB01-0AB0 B) DI 4 x 24 V DC, High Feature; with diagnostics • Short-circuit monitoring Ordering unit 5 items 6ES7 131-4BD01-0AB0 DI 4 x 24 to 48 V AC/DC, High Feature; with diagnostics • Wire break monitoring (external resistance circuit required) • Monitoring of the fuse • Monitoring of the load voltage Ordering unit 5 items 6ES7 131-4CD00-0AB0 DI 4 x 24 V DC, NAMUR Ordering unit 1 item 6ES7 131-4RD00-0AB0 B) Relay output (suitable for solenoid valves, contactors, motor starters, miniature motors and indicator lights) DI 2 x 120 V AC, standard Ordering unit 5 items 6ES7 131-4EB00-0AB0 B) 6ES7 132-4HB01-0AB0 DI 2 x 230 V AC, standard Ordering unit 5 items 6ES7 131-4FB00-0AB0 B) 2 x RO, NO contact 24 to 120 V DC/5 A 24 to 230 V AC/5 A • Connection of a default value by channel in the event of CPU failure (parameterizable) Ordering unit 5 items 6ES7 138-4FA03-0AB0 B) 2 x RO, changeover contact 24 to 48 V DC/5 A 24 to 230 V AC/5 A • Connection of a default value by channel in the event of CPU failure (parameterizable) Ordering unit 5 items 6ES7 132-4HB10-0AB0 B) 6ES7 138-4FB02-0AB0 B) • 15 mm wide (Ordering unit 5 items) 6ES7 138-4AA01-0AA0 B) • 30 mm wide (Ordering unit 1 item) 6ES7 138-4AA11-0AA0 B) B) 4/8 F-DI 24 V DC PROFIsafe 8 DI safety-related SIL 2 or 4 DI safety-related SIL 3, with diagnostics • Cyclic short-circuit test • Discrepancy monitoring of 2 channels for SIL 3 (adjustable discrepancy time) • Safe monitoring of communication with PROFIsafe Ordering unit 1 item 6ES7 132-4FB01-0AB0 B) Failsafe digital output Digital outputs for DC voltage (suitable for solenoid valves, DC contactors, indicator lights etc.) DO 2 x 24 V DC/0.5 A, standard Ordering unit 5 items 6ES7 132-4BB01-0AA0 DO 2 x 24 V DC/2 A, standard Ordering unit 5 items 6ES7 132-4BB31-0AA0 DO 2 x 24 V DC/0.5 A, High Feature, with diagnostics • Connection of a default value by channel in the event of CPU failure (parameterizable) • Short-circuit monitoring by channel • Broken wire monitoring by channel (when "1" signal) Ordering unit 5 items 6ES7 132-4BB01-0AB0 B) B) 4 F-DO 24 V DC/2 A PROFIsafe Safety-related up to SIL 3, with diagnostics, switching to low/high • Short-circuit monitoring by channel • Overload monitoring by channel • Broken wire monitoring by channel (when "1" signal) • Safe monitoring of communication with PROFIsafe • Diagnostics inside module Ordering unit 1 item Accessories Reserve modules for ET 200S for reserving unused slots for any electronics module For further accessories, e.g. for labeling, see Catalog IK PI B) Subject to export regulations: AL: N, ECCN: EAR99H 11/46 B) Digital output for AC voltage (suitable for solenoid valves, AC contactors, indicator lights etc.) DO 2 x 24 to 230 V AC, 2 A • Connection of a default value by channel in the event of CPU failure (parameterizable) Ordering unit 5 items Failsafe digital input 11 Order No. DO 2 x 24 V DC/2 A, High Feature, with diagnostics • Connection of a default value by channel in the event of CPU failure (parameterizable) • Short-circuit monitoring by channel • Broken wire monitoring by channel (when "1" signal) Ordering unit 5 items Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Process I/O ET 200S distributed I/O Analog electronics modules ■ Overview • Analog inputs and outputs for the ET 200S • Can be plugged onto TM-E terminal modules with automatic coding. • High-feature variants with enhanced accuracy and resolution • Hot swapping of modules possible ■ Design Possible combinations of the TM-E terminal modules and analog modules TM-E terminal modules for electronics modules Screw-type terminal Order No. 6ES7 193... TM-E15S26-A1 …4CA40-0AA0 TM-E15S24-A1 …4CA20-0AA0 TM-E15S24-01 …4CB20-0AA0 TM-E15S23-01 …4CB00-0AA0 TM-E15S24-AT …4CL20-0AA0 Spring terminal Order No. 6ES7 193... TM-E15C26-A1 …4CA50-0AA0 TM-E15C24-A1 …4CA30-0AA0 TM-E15C24-01 …4CB30-0AA0 TM-E15C23-01 …4CB10-0AA0 TM-E15C24-AT …4CL30-0AA0 Fast Connect Order No. 6ES7 193... TM-E15N26-A1 …4CA80-0AA0 TM-E15N24-A1 …4CA70-0AA0 TM-E15N24-01 …4CB70-0AA0 TM-E15N23-01 …4CB60-0AA0 -- 2AI U Standard 2AI U High Feature • • • • 2AI I 2WIRE Standard • • • • • • • • • • • • • • Electronics modules 2AI I 2/4WIRE High Feature 2 AI I 4WIRE Standard 2AI RTD Standard 2AI RTD High Feature 2 AI TC Standard • • • • 2 AI TC High Feature 2AO U Standard 2AO U High Feature • 2 AO I Standard 2AO I High Feature • • • • 11 • • Siemens ST PCS 7 · November 2007 11/47 © Siemens AG 2007 Process I/O ET 200S distributed I/O Analog electronics modules ■ Selection and Ordering Data ■ Selection and Ordering Data Order No. 11 • AI 2 x U (± 5 V, 1 ... 5 V, ± 10 V) / 13 bit, standard - Module-internal diagnostics - Overflow/underflow diagnostics 6ES7 134-4FB01-0AB0 • AI 2 x I, 2-wire transmitter (4 ... 20 mA) / 13 bit, standard - Module-internal diagnostics - Overflow/underflow diagnostics - Wire break monitoring 6ES7 134-4GB01-0AB0 • AI 2 x I, 4-wire transmitter (± 20 mA, 4 ... 20 mA) / 13 bit, standard - Module-internal diagnostics - Overflow/underflow diagnostics - Wire break monitoring 6ES7 134-4GB11-0AB0 • AI 2 x TC / 15 bit, standard - Module-internal diagnostics - Overflow/underflow diagnostics - Wire break monitoring - Compensation through external Pt100 in the same station with AI 2 x RTD standard 6ES7 134-4JB00-0AB0 • AI 2 x RTD / 15 bit, standard - Module-internal diagnostics - Overflow/underflow diagnostics - Wire break monitoring - Resistance thermometer Pt100, Ni100 (2, 3 or 4 wires) 6ES7 134-4JB50-0AB0 • AI 2 x U (1...5 V, ± 5 V, ± 10 V) / 15 bit, High Feature - Module-internal diagnostics - Overflow/underflow diagnostics 6ES7 134-4LB02-0AB0 • AI 2 x I, 2/4-wire transmitter (± 20 mA, 4 ... 20 mA) / 15 bit, high feature - Module-internal diagnostics - Overflow/underflow diagnostics - Wire break monitoring 6ES7 134-4MB02-0AB0 B) • AI 2 x TC / 15 bit, high feature - Module-internal diagnostics - Overflow/underflow diagnostics - Wire break monitoring - Internal temperature compensation with TM-E15S24-AT or TM-E15C24-AT terminal module 6ES7 134-4NB01-0AB0 B) • AI 2 x RTD / 15 bit, high feature - Module-internal diagnostics - Overflow/underflow diagnostics - Wire break monitoring - Resistance thermometer Pt100/200/500/1000, Ni100/1000 (2, 3 or 4 wires) - Temperature in Celsius or Fahrenheit 6ES7 134-4NB51-0AB0 B) 11/48 Order No. Analog output Analog input B) B) B) B) • AO 2 x U (1...5 V / 12 bit, ±10 V / 13 bit), standard - Module-internal diagnostics - Connection of substitute value in event of CPU stop (parameterizable) - Short-circuit monitoring 6ES7 135-4FB01-0AB0 B) • AO 2 x I (± 20 mA, 4 ... 20 mA) / 13 bit, standard - Module-internal diagnostics - Connection of substitute value in event of CPU stop (parameterizable) - Wire break monitoring 6ES7 135-4GB01-0AB0 B) • AO 2 x U (1 ... 5 V, ± 10 V) / 15 bit, high feature - Module-internal diagnostics - Connection of substitute value in event of CPU stop (parameterizable) - Short-circuit monitoring 6ES7 135-4LB02-0AB0 B) • AO 2 x I (± 20 mA, 4 ... 20 mA) / 15 bit, high feature - Module-internal diagnostics - Connection of substitute value in event of CPU stop (parameterizable) - Wire break monitoring 6ES7 135-4MB02-0AB0 B) • 15 mm wide (5 units) 6ES7 138-4AA01-0AA0 B) • 30 mm wide (1 unit) 6ES7 138-4AA11-0AA0 B) Accessories Reserve modules for ET 200S for reserving unused slots for any electronics module B) For further accessories, e.g. for labeling, see Catalog IK PI Siemens ST PCS 7 · November 2007 B) Subject to export regulations: AL: N, ECCN: EAR99H © Siemens AG 2007 Process I/O ET 200S distributed I/O Motor starters ■ Overview ■ Design Power modules and motor starters are operated on the terminal modules which are assigned to them in the tables in the sections "High Feature motor starters" and "Safety-oriented motor starters". The terminal modules are a carrier system which is simultaneously used for the power supply to the motor starters (electronics: 24 V DC and load: 400 V AC). 24 V DC for the electronics is provided by the power module inserted to the left of the first motor starter. The power module and the downstream motor starters constitute a potential group whose scope is limited by the current carrying capacity of the power module. When this limit is reached, a new potential group must be established with a further power module. The load current is applied to the first (left) TM-xxxxS32 motor starter terminal module, and reaches the other motor starters via the power bus of the adjacent TM-xxxxS31 terminal modules. The power bus is designed for loads up to 50 A. When this limit is reached, a new load group must be started with a further TM-xxxxS32 terminal module, and provided with load current. • Completely factory-wired motor starters for switching and protecting any three-phase loads • Can be used as a direct-on-line, reversing or soft starter • High Feature motor starter with a combination comprising starter circuit breaker, solid-state overload protection and contactor or soft starter up to 7.5 kW • Safety-oriented motor starters based on the High Feature motor starters (direct-on-line and reversing starters) with integral redundancy function for shutdown reliability up to Category 4 (EN 954-1) • With self-assembling 50 A power bus, i.e. the load current is only supplied once for a group of motor starters • Hot swapping is permissible • Inputs and outputs for activating and signaling the states have been integrated • Diagnostics capability for active monitoring of the switching and protection functions • Can be combined with brake control module for controlling electromechanical brakes in three-phase motors Brake control modules for motor starters High Feature and safety-oriented motor starters can be expanded by a brake control module for controlling electromechanical brakes in three-phase motors. The following modules are available: • For brakes with external supply 24 V DC/4 A: - xB3 (with two optional inputs for special functions) - xB1 • For brakes with internal supply 500 V DC/0.7 A: - xB4 (with two optional inputs for special functions) - xB2 The externally supplied 24 V DC brakes can be released independent of the switching status of the motor starter. The 500 V DC brakes, on the other hand, are generally supplied direct from the junction plate of the motor via a rectifier module and cannot be released if the motor starter is switched off. These brakes cannot be used in conjunction with the DSS1e-x motor starter (direct-on-line soft starter). The outputs of the brake control modules can also be used for other purposes e.g. for controlling DC valves. Independent special functions can be implemented with the help of two optional local inputs each on a brake control module xB3 or xB4 and a control module 2DI of the High Feature motor starter. These operate independently of the bus and higher-level control, e.g. to implement rapid stop functions for slide controls. Brake control modules are operated on different terminal modules depending on the design: Brake control modul Terminal module for brake control module xB1 oder xB2 TM-xB15S24-01 3RK1 903-0AG00 -- xB3 oder xB4 -- TM-xB215S24-01 3RK1 903-0AG01 Siemens ST PCS 7 · November 2007 11/49 11 © Siemens AG 2007 Process I/O ET 200S distributed I/O Motor starters High Feature motor starters The High Feature motor starters are used together with the PM-D power module. Combined with a terminal module according to the table, a PM-D power module opens up a new potential group. The scope of the group is limited in that the value specified for the current carrying capacity of the power module (10 A for PM-D) must not be exceeded by the total current of all modules in a potential group. The PM-D handles the following tasks for the motor starters in a potential group: • Supply of voltages for the electronics via the voltage buses of the terminal modules • Monitoring of voltages for the electronics and contactors Terminal modules for motor starters and power modules With power bus supply for one load group, including 3 caps for termination of power bus TM-DS65S32 3RK1 9030AK00 TM-RS130S32 3RK1 9030AL00 -- With power bus bushing TM-DS65S31 3RK1 9030AK10 TM-RS130S31 3RK1 9030AL10 -- -- -- TM-P15-S2701 3RK1 9030AA00 With screw terminals • Motor starters DS1e-x High Feature direct-online starter • DSS1e-x High Feature direct-online soft starter • RS1e-x High Feature reversing starter 11 With power bus supply for one load group, including 3 caps for termination of power bus TM-FD65S32 3RK1 9033AC00 TM-FRS130S32 3RK1 9033AD00 -- With power bus bushing TM-FD65S31 3RK1 9033AC10 TM-FRS130S31 3RK1 9033AD10 -- -- -- TMPF30S47-F0 3RK1 9033AA00 With screw terminals Power module F-DS1e-x High Feature direct-on-line starter • F-RS1e-x High Feature reversing starter • Supplementary/expansion modules for safety-oriented motor starter applications The PM-D F X1 power/expansion module permits selective shutdown of 1 to 6 shut-down groups through external safety devices (e.g. safety relay or AS-i safety monitor). The PM-D F X1 uses the safety-oriented shut-down signals connected to the module to trigger the downstream failsafe motor starters which then safely switch off the assigned motors. In addition, external safety devices can also be powered by a safe 24 V DC voltage V1 via the safety-oriented PM-D F X1 power/expansion module. • Safety-oriented motor starters In EMERGENCY STOP applications, safety-oriented motor starters can be shut down selectively by means of the upstream PM-D F PROFIsafe power module. Up to 6 shut-down groups can be formed per power module. The PM-D F PROFIsafe obtains the shut-down signal from the F/FH automation system via the interface module of the ET 200S. Combined with a terminal module according to the table, a PM-D F PROFIsafe power module opens up a new potential group. The scope of the group is limited in that the total current of all modules in a potential group must not exceed the current carrying capacity of the power module (with PM-D F PROFIsafe: inrush current 10 A; continuous current 5 A). The F-CM contact multiplier equipped with four safe floating contacts (NO contacts) can be used together with the PM-D F PROFIsafe or the PM-D F X1 as an interface to plants with conventional safety engineering. It has internal diagnostics functions, and can be set to one of 6 shut-down groups. Terminal modules for supplementary/expansion modules Without supply from left (as power module) TM-PFX30 S47G1 3RK1 903-3AE00 -- With supply from left (for expansion) TM-PFX30 S47G0 3RK1 903-3AE10 -- -- TM-FCM30-S47 3RK1 903-3AB10 Additional/expansion modules PM-D F X1 safety-oriented power/ expansion module F-CM safety-oriented contact multiplier 11/50 • PM-D F PROFIsafe Motor starters Power module PM-D 24 V DC Terminal modules for motor starters, power modules and supplementary/expansion modules Siemens ST PCS 7 · November 2007 • • © Siemens AG 2007 Process I/O ET 200S distributed I/O Motor starters ■ Selection and Ordering Data ■ Selection and Ordering Data Order No. DS1e-x direct-on-line starters Mechanical switching, electronic overload protection • Up to 1.1 kW/400 V; 0.3 to 3.0 A 3RK1 301-0AB10-0AA4 • Up to 3.0 kW/400 V; 2.4 to 8.0 A 3RK1 301-0BB10-0AA4 • Up to 7.5 kW/400 V; 2.4 to 16.0 A 3RK1 301-0CB10-0AA4 DSS1e-x soft starters Electronic switching, electronic overload protection • Up to 1.1 kW/400 V; 0.3 to 3.0 A 3RK1 301-0AB20-0AA4 • Up to 3.0 kW/400 V; 2.4 to 8.0 A 3RK1 301-0BB20-0AA4 • Up to 7.5 kW/400 V; 2.4 to 16.0 A 3RK1 301-0CB20-0AA4 RS1e-x reversing starters Mechanical switching, electronic overload protection • Up to 1.1 kW/400 V; 0.3 to 3.0 A 3RK1 301-0AB10-1AA4 • Up to 3.0 kW/400 V; 2.4 to 8.0 A 3RK1 301-0BB10-1AA4 • Up to 7.5 kW/400 V; 2.4 to 16.0 A 3RK1 301-0CB10-1AA4 Order No. Control modules High Feature motor starters With diagnostics, expandable with brake control module • Control module 2DI COM DC 24 V Digital input module with two inputs for parameterizable motor starters, for mounting on front of motor starter, with PC connection (LOGO! PC cable 6ED10571AA00-0AB0 required) 3RK1 903-0CH10 A) • Control module 2DI LC COM DC 24 V Like control module 2DI COM, plus input for switching to manual local mode 3RK1 903-0CH20 A) M65-PEN-F infeed module 65 mm wide, incl. two caps, in combination with TM-DS6532/TM-RS130-S32 3RK1 903-2AC00 M65-PEN-S connection module 65 mm wide, in combination with TM-DS65-31/TM-RS130-S31 3RK1 903-2AC10 Brake control expansion module For motors with mechanical brake Accessories Terminal modules for motor starters • TM-DS65-S32 for DS1e-x, DSS1e-x direct starters with supply connection for power bus, incl. 3 caps for terminating the power bus 3RK1 903-0AK00 A) • TM-DS65-S31 for DS1e-x, DSS1e-x direct starters without supply connection for power bus 3RK1 903-0AK10 • TM-RS130-S32 for RS1e-x reversing starter with supply connection for power bus, incl. 3 caps for connecting the power bus 3RK1 903-0AL00 • TM-RS130-S31 for RS1e-x reversing starter without supply connection for power bus 3RK1 903-0AL10 A) PM-D power module for direct and reversing starters; 24 V DC, with diagnostics 3RK1 903-0BA00 A) Terminal module for PM-D power module TM-P15-S27-01 3RK1 903-0AA00 A) A) • xB1 24 V DC / 4 A 3RK1 903-0CB00 A) • xB2 500 V DC / 0.7 A 3RK1 903-0CC00 • xB3 24 V DC / 4 A, DI 2 x 24 V DC with two optional inputs 3RK1 903-0CE00 A) • xB4 500 V DC / 0.7 A, DI 2 x 24 V DC with two optional inputs 3RK1 903-0CF00 A) Terminal modules for brake control expansion module • TM-xB15S24-01 for xB1 or xB2 3RK1 903-0AG00 • TM-xB215S24-01 for xB3 or xB4 3RK1 903-0AG01 A) 11 A) Subject to export regulations: AL: N, ECCN: EAR99 Jumper modules • M15-PEN Terminal block PE/N, 15 mm wide, for jumpering a 15-mm module 3RK1 903-0AH00 • M30-PEN Terminal block PE/N, 30 mm wide, for jumpering a 30-mm module 3RK1 903-0AJ00 • M15-L123 Terminal block L1/L2/L3, 15 mm wide, for jumpering a 15-mm module 3RK1 903-0AE00 • M30-L123 Terminal block L1/L2/L3, 30 mm wide, for jumpering a 30-mm module 3RK1 903-0AF00 Siemens ST PCS 7 · November 2007 11/51 © Siemens AG 2007 Process I/O ET 200S distributed I/O Motor starters ■ Selection and Ordering Data ■ Selection and Ordering Data Order No. Safety-related motor starters With diagnostics, expandable with brake control module F-DS1e-x safety-related direct starter Mechanical switching, electronic overload protection • Up to 1.1 kW/400 V; 0.3 to 3.0 A 3RK1 301-0AB13-0AA4 • Up to 3.0 kW/400 V; 2.4 to 8.0 A 3RK1 301-0BB13-0AA4 • Up to 7.5 kW/400 V; 2.4 to 16.0 A 3RK1 301-0CB13-0AA4 F-RS1e-x safety-related reversing starter Mechanical switching, electronic overload protection • Up to 1.1 kW/400 V; 0.3 to 3.0 A 3RK1 301-0AB13-1AA4 • Up to 3.0 kW/400 V; 2.4 to 8.0 A 3RK1 301-0BB13-1AA4 • Up to 7.5 kW/400 V; 2.4 to 16.0 A 3RK1 301-0CB13-1AA4 • xB3 24 V DC / 4 A, DI 2 x 24 V DC with two optional inputs 3RK1 903-0CE00 A) • xB4 500 V DC / 0.7 A, DI 2 x 24 V DC with two optional inputs 3RK1 903-0CF00 A) Terminal modules for brake control expansion module TM-xB215S24-01 for xB3 or xB4 3RK1 903-0AG01 A) PM-D F X1 power module For power supply of emergency stop signals of external safety units; for 6 switch-off groups, 24 V DC 3RK1 903-3DA00 A) Terminal module for PM-D F X1 power module Accessories • TM-PFX30 S47-G0 With infeed on left 3RK1 903-3AE10 A) Terminal modules for safetyrelated motor starters • TM-PFX30 S47-G1 Without infeed on left 3RK1 903-3AE00 A) • For F-DS1e-x direct starter, with coding F-CM contact multiplexer With 4 safe floating contacts 3RK1 903-3CA00 Terminal module for F-CM contact multiplexer TM-FCM30 S47-F01 3RK1 903-3AB10 - TM-FDS65-S32 with supply connection for power bus 3RK1 903-3AC00 A) - TM-FDS65-S31 without supply connection for power bus 3RK1 903-3AC10 A) A) Subject to export regulations: AL: N, ECCN: EAR99 • For F-RS1e-x reversing starter, with coding 11 Order No. Brake control expansion module For motors with mechanical brake - TM-FRS130-S32 with supply connection for power bus 3RK1 903-3AD00 A) - TM-FRS130-S31 without supply connection for power bus 3RK1 903-3AD10 A) PM-D F PROFIsafe power module for direct and reversing starters; 24 V DC, with diagnostics 3RK1 903-3BA01 A) Terminal module for PM-D F PROFIsafe power module TM PF30 S47-F0 3RK1 903-3AA00 A) Jumper modules and control modules See under High Feature motor starters M65-PEN-F infeed module 65 mm wide, incl. two caps, in combination with TM-DS65-32 / TM-RS130-S32 3RK1 903-2AC00 M65-PEN-S connection module 65 mm wide, in combination with TM-DS65-31/TM-RS130-S31 3RK1 903-2AC10 11/52 Siemens ST PCS 7 · November 2007 Note: For color-coded labels and further accessories for ET 200S configurations with High Feature motor starters and for ET 200S configurations with safety-related motor starters, refer to "Distributed I/Os / ET 200S" in the A&D Mall or in the Catalogs IK PI and CA 01. © Siemens AG 2007 Process I/O ET 200S distributed I/O SIGUARD safety technology ■ Overview ■ Design Components required for applications with safety requirements Components required Safety category acc. to EN 954-1 PM-D F1...5 2 3 4 • • • 1) • • • • 2) • 2) • 2) PM-X • • • TM-X15 S27-01 • • • • • TM-PF30 S47-.. F-Kit 1/2 Redundantly switching, external infeed contactor The SIGUARD safety system is based on special terminal and power modules that can be combined with the ET 200S motor starters and a failsafe kit to achieve the highest safety category 4 (according to EN 954-1). It enables the evaluation of emergency stop circuits, the monitoring of protective doors or the implementation of time-delayed shut-downs. The costs involved in the configuration and wiring of conventional safety systems are no longer incurred. All standard safety applications can be covered with SIGUARD (see the ET 200S manual for examples of applications). 1) PM-D F3 power module only approved up to Category 3 2) F kit required for standard motor starter only; already integrated in high feature motor starter Possible combinations of power and terminal modules PM-D PM-D PM-D PM-D PM-D PM-X F1 F2 F3 F4 F5 TM-PF30 S47-B1 1) • • TM-PF30 S47-B0 2) • • TM-PF30 S47-C1 3) • • TM-PF30 S47-C0 4) • • • TM-PF30 S47-D0 • TM-X15 S27-01 1) For F1 or F2 in higher-level or individual safety group (voltage group) 2) For F1 or F2 in lower-level cascaded safety group (partial voltage group) 3) For expansion with F3 or F4 in separate ET 200S station (voltage group) 4) For expansion with F3 or F4 in the same ET 200S station (partial voltage group) 11 Siemens ST PCS 7 · November 2007 11/53 © Siemens AG 2007 Process I/O ET 200S distributed I/O SIGUARD safety technology 11 Terminal modules for SIGUARD power modules TM-X terminal module for SIGUARD connection module The terminal modules integrate the SIGUARD power modules. Using different terminal modules it is possible to separate various safety circuits by function or else to cascade them. Each such group has to be terminated with a SIGUARD PM-X connection module. • The TM-PF30 S47-B1 terminal module always stands at the beginning of a safety segment and integrates either the PM-D F1 power module for emergency stop applications or the PM-D F2 power module for protective door monitoring. The 2-channel connection of the safety sensor (e.g. emergency stop button) as well as the 24 V DC supply for the electronics (V1) and the contactor supply (V2) of the motor starters have to be connected to this terminal module. Connections for the ON button (enable) and the safe output of the power module are also available. • The TM-PF30 S47-B0 terminal module is used for the cascading of subordinate safety segments and integrates either the PM-D F1 power module for emergency stop applications or the PM-D F2 power module for protective door monitoring. No additional auxiliary voltage has to be connected to this terminal module. The supply is fed through the terminal module voltage buses from the preceding PM-D F1 or PM-D F2 power module. Switching off the voltage of the preceding power module means that the terminal module has no voltage either. • The TM-PF30 S47-C1 terminal module always stands at the beginning of an expansion of a safety segment in a new station, e.g. in an interlaced configuration. It integrates the PM-D F3 power module for time-delayed shut-down or the PM-D F4 power module for direct shut-down in physically separated ET 200S stations. The 24-V voltages for the electronics (V1) and for the contactor supply (V2) are provided again. The shut-down command of a preceding ET 200S station is integrated through a safe input. Separate terminals are available for connecting the feedback circuit to the upstream ET 200S station. It is not possible to connect safety sensors to this terminal module. • The TM-PF30 S47-C0 terminal module is used to cascade subordinate safety segments and integrates either the PMDF3 power module for time-delayed shut-down or the PM-DF4 power module. Only the supply voltage V2 for the contactor supply need be connected on this terminal module. The supply with V1 is via the voltage buses of the terminal modules of the previous power modules (partial voltage group). It is not possible to connect safety sensors to this terminal module. • The TM-PF30 S47-D0 terminal module is used to integrated the PM-D F5 power module. At this terminal module it is possible to forward safe signals to external systems through four groups, each with two safety relay contacts in redundant configuration. The terminal module must always be positioned between one of the above mentioned terminal modules and a terminal module for the TM-X connection module. It is not possible to connect safety sensors to this terminal module. For connecting an external incoming supply contactor (second shut-down option) in Categories 3 and 4. The SIGUARD connection module is inserted to the right of the last motor starter in a safety segment. The terminals for connecting the positively driven NC contact of the contactor are located alongside the terminals for connecting the contactor coil on the TM-X terminal module. If no redundant contactor is required in Category 2 (EN 954-1), for example, the feedback circuit has to be closed at these terminals by a jumper. This arrangement is also used instead of SIGUARD power module as an interface to the external safety relay when external safety relays are used. 11/54 Siemens ST PCS 7 · November 2007 SIGUARD PM-D F1/F2/F3/F4/F5 power modules The following SIGUARD PM-D power modules are available for selection: • PM-D F1 for evaluating emergency stop circuits with the function "Monitored start". • PM-D F2 for monitoring safety doors with the function "Automatic start". • PM-D F3 as expansion for PM-D F1/F2 for time-delayed tripping. • PM-D F4 for expanding safety circuits with other ET200S motor starters, e.g. on a different tier. • PM-D F5 for transmitting the status of PM-D F1...4 over four floating relay circuits to external safety devices (contact multipliers) No additional PM-S power module is required when using the SIGUARD power modules. SIGUARD PM-D F1/F2/F3/F4 power modules monitor auxiliary voltages and contain the complete functionality of a safety relay. The PM-D F1 and PM-D F2 modules can be combined with the PM-D F3 or PM-D F4 modules. A PM-D F5 can be arranged in any position between PM-D F1...4 and a PM-X. Every safety circuit, starting with a PM-D F1 ... 4, has to be terminated with a PM-X. Failsafe kit Every standard motor starter in a safety segment has to be supplemented by the failsafe kit (F-kit) in order to monitor the switching function. F-kit 1 supplements the DS1-x direct-on-line starter, F-kit 2 the RS1-x reversing starter. The F-kits comprise • contact carriers for the terminal modules, • one or two auxiliary switch blocks for the contactor(s) of the motor starter and • connecting lines. High feature motor starters and their terminal modules come equipped with the F-kit functions. © Siemens AG 2007 Process I/O ET 200S distributed I/O SIGUARD safety technology ■ Selection and Ordering Data ■ Selection and Ordering Data Order No. Order No. Accessories SIGUARD Terminal Modules PM-PF30 S47 B1 Terminal Module For PM-D F1/2 power modules with U1/U2 incoming supply and sensor connection 3RK1 903-1AA00 A) PM-PF30 S47 B0 Terminal Module For PM-D F1/2 power modules with sensor connection 3RK1 903-1AA10 A) PM-PF30 S47 C1 Terminal Module For PM-D F3/4 power modules with U1/U2 incoming supply and IN+/IN- control input 3RK1 903-1AC00 A) PM-PF30 S47 C0 Terminal Module For PM-D F3/4 power modules with U2 incoming supply 3RK1 903-1AC10 PM-PF30 S47 D0 Terminal Module For PM-D F5 power modules 3RK1 903-1AD10 PM-X15 S27 01 Terminal Module For SIGUARD connection module 3RK1 903-1AB00 PM-X SIGUARD Connection module for incomingfeeder contactor; external safety circuits 3RK1 903-1CB00 A) Failsafe kit 1 Failsafe kit for DS1-x standard motor starter (not necessary for High Feature motor starter) 3RK1 903-1CA00 A) Failsafe kit 2 Failsafe kit for RS1-x standard motor starter (not necessary for High Feature motor starter) 3RK1 903-1CA01 A) A) Subject to export regulations: AL: N, ECCN: EAR99 A) SIGUARD Power Modules PM-D F1 SIGUARD Power Module EMERGENCY STOP; monitored start; 2-channel 3RK1 903-1BA00 PM-D F2 SIGUARD Power Module Protective door; autostart; 2-channel 3RK1 903-1BB00 PM-D F3 SIGUARD Power Module Expansion to F1/2 for an additional voltage group; time-delayed 3RK1 903-1BD00 PM-D F4 SIGUARD Power Module Expansion to F1/2 for an additional voltage group 3RK1 903-1BC00 PM-D F5 SIGUARD Power Module Expansion to PM-D F1 up to PM-D F4, contact multiplier 3RK1 903-1BE00 11 Siemens ST PCS 7 · November 2007 11/55 © Siemens AG 2007 Process I/O Dezentrale Peripherie ET 200pro Introduction ■ Overview ■ Design The architecture of the ET 200pro is based on the proven separation of modules from the bus/power supply connection system. This permits the T functionality for bus and 24 V DC power supply for the interface module, and prewiring of sensor/actuator connections for the electronics modules (independent wiring). When servicing, the independent wiring permits hot swapping of an electronics module without having to switch off the remaining station. This can continue without interruption during the replacement. When replacing an electronics module, the complete I/O wiring remains on the connection module, and need be neither labeled nor removed. Up to 16 electronics modules can be arranged in any order between the interface module (left) and the terminating module (right limit). Modules of an ET 200pro station 11 SIMATIC ET 200pro is a modular I/O system with high IP65/66/67 protection suitable for use at machine level outside the control cabinet. As a result of the innovative design, the ET 200pro has a relatively small size and can be flexibly adapted to the requirements of the respective automation task with regard to the connection system and I/Os. Summary of the most important features of the SIMATIC ET 200pro: • Distributed I/O system with IP65/67 protection for use without a control cabinet at machine level • Small, multi-functional complete solution: analog and digital I/O modules as well as safety-related digital I/O modules • Communication over PROFIBUS DP, transmission rate up to 12 Mbit/s • Mixed design of fail-safe and standard modules possible in the same station • Free selection of connection system: direct, ECOFAST or M12 7/8" • Power module for simple implementation of load groups • Hot swapping of modules • Simple assembly and independent wiring • Comprehensive diagnostics: exact to the module or channel The ET 200pro modules are usually designed in two or three parts. Interface and power modules as well as digital and analog electronics modules comprise: • Bus module as mechanical and electrical connection element of the individual ET 200pro modules (they form the backplane bus of the system) • Electronics or interface module • Connection module The ET 200pro modules are fitted when delivered on the associated bus module. An ET 200pro station comprises: • Module support • Interface module for PROFIBUS DP • Connection module for the PROFIBUS DP interface module - CM IM DP direct with up to 6 M20 cable glands - CM IM DP ECOFAST Cu - CM IM DP M12 7/8" • Max. 16 electronics modules with associated connection modules which may be assembled up to a station width of 1 m • Terminating module (included in scope of delivery of interface module) Expansion modules The following expansion modules are available: • Digital electronics modules • Analog electronics modules • Safety-related electronics modules • I/O connection modules - CM IO 4 x M12 for digital or analog electronics modules - CM IO 8 x M12 for digital electronics modules - CM IO 12 x M12 for 4/8 F-DI/4 F-DO - CM IO 16 x M12 for 8/16 F-DI • Power module electronics PM-E • Connection modules for power module - CM PM-E direct with up to 2 M20 cable glands - CM PM-E ECOFAST Cu - CM PM-E 7/8" 11/56 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Process I/O Dezentrale Peripherie ET 200pro Introduction Module support Various module supports are available for mounting the ET 200pro: • Narrow module support The narrow module support permits complete preassembly on a workbench as a result of two mounting flanges outside the ET 200pro station. Expansion limits • Number of electronics modules per station (between interface module and terminating module): up to 16 • Max. width (without module support): 1 m • Electronics/sensor supply 1L+ max. 5 A per ET 200pro station • Load voltage supply 2L+ max. 10 A per potential group • Maximum address range of an ET 200pro station: 244 bytes for inputs and 244 bytes for outputs ET 200pro configuration The SIMATIC ET 200 configurator can be used to compile an ET 200pro station rapidly and simply. It knows the configuration rules, and supports selection of all components and associated accessories in interactive mode. The SIMATIC ET 200 is available in the current CD-ROM Catalog CA 01 and on the Internet. Additional information is available in the Internet under: http://www.siemens.com/et200 • Compact-narrow module support The compact-narrow module support permits the most spacesaving design. ■ Integration The distributed ET 200pro system is connected to SIMATIC PCS 7 automation systems (controllers) over PROFIBUS DP. Data transfer rates of up to 12 Mbit/s are possible. The ET 200pro is integrated into SIMATIC PCS 7 using standard driver blocks. You can therefore configure and parameterize the ET 200pro in the SIMATIC Manager of the engineering system extremely simply using HW-Config. 11 Siemens ST PCS 7 · November 2007 11/57 © Siemens AG 2007 Process I/O Dezentrale Peripherie ET 200pro Introduction ■ Technical specifications General technical specifications Electronics modules • Digital inputs/outputs • Analog inputs/outputs • Safety-related digital inputs/ outputs Connection system for actuator/ sensor M12 round plug connection with standard assignments for actuator/sensor Data transfer rate, max. 12 Mbit/s (PROFIBUS DP) Power supply 24 V DC Current consumption of an ET 200pro (internal and sensor supply, non-switched voltage), up to 55 °C, max. ≤5A Load current for ET 200pro per incoming supply (IM, PM, switched voltage), up to 55 °C, max. 10 A For total configuration with looping through (several ET 200pro), up to 55 °C, max. 16 A (with direct connection module) Degree of protection IP65/66/IP67 for interface, digital and analog modules Material Thermoplast (glass-fiber reinforced) Ambient conditions Temperature 0 ... 55 °C (-25 °C on request) Relative humidity 5 ... 100 % Atmospheric pressure 795 ... 1080 hPa Mechanical stress 11 Vibrations Vibration test according to IEC 60068, Part 2-6 (sinusoidal) • Constant acceleration 5 g, occasionally 10 g, for interface, digital and analog modules • 2 g for motor starters Shock • Shock test according to IEC 680068 Part 2-27, half-sine, 30 g, 18 ms duration for interface, digital and analog modules • 15 g, 11 ms duration for motor starters Approvals UL, CSA and cULus 11/58 Siemens ST PCS 7 · November 2007 For detailed technical specifications, especially for individual components such as interface module, power module and electronics modules, see: • Catalog IK PI • Mall/CA 01 under "Distributed I/Os / ET 200pro" © Siemens AG 2007 Process I/O Dezentrale Peripherie ET 200pro Interface module IM 154-2 DP High Feature ■ Overview ■ Selection and Ordering Data Order No. 6ES7 154-2AA00-0AB0 B) • CM IM DP ECOFAST connection module for connection of PROFIBUS DP and 24 V DC power supply to PROFIBUS interface modules, 2 ECOFAST Cu connections 6ES7 194-4AA00-0AA0 B) • CM IM DP direct connection module for direct connection of PROFIBUS DP and 24 V DC power supply to PROFIBUS interface modules, up to six M20 cable glands 6ES7 194-4AC00-0AA0 B) • CM IM DP M12 7/8" connection module for connection of PROFIBUS DP and 24 V DC power supply to PROFIBUS interface modules, 2 x M12 and 2 x 7/8" 6ES7 194-4AD00-0AA0 B) IM154-2 High Feature interface module for ET 200pro; for communication between ET 200pro and host masters over PROFIBUS DP; support of PROFIsafe Connection module for IM154-2 High Feature interface module The IM 154-2 DP High Feature interface module is responsible for PROFIBUS communication between the ET 200pro station and the host automation system (controller) as PROFIBUS DP master. The scope of delivery of the interface module also includes a terminating module which is plugged in following the last electronics module of the station. ■ Function Features of the IM 154-2 DP High Feature interface module • Mounted on delivery on the bus module • Connects the ET 200pro station to the PROFIBUS DP via the connection module • Prepares the data for the connected electronics modules • Max. 16 electronics modules can be operated on an interface module - also safety-related • PROFIBUS DP address of the ET 200pro station can be set on the connection module • Terminating resistor of the PROFIBUS DP can be switched on and off on the connection module • Maximum address range: 244 bytes for inputs and 244 bytes for outputs • Powers the ET 200pro station via the connection module with the sensor/electronics supply 1L+ and the load power supply 2L+ • Integral power module for the load power supply 2L+ ■ Technical specifications For detailed technical specifications of the interface module, see: • Catalog IK PI • Mall/CA 01 under "Distributed I/Os / ET 200pro" ■ Accessories Connection modules Cables and further accessories For cables and further accessories for CM IM DP ECOFAST, CM IM DP direct and CM IM DP M12 7/8" connection modules, see Catalog IK PI or Mall/CA 01 under "Distributed I/O / ET 200pro" General accessories ET 200pro module support • Narrow, for interface, electronics and power modules - 500 mm 6ES7 194-4GA00-0AA0 - 1000 mm 6ES7 194-4GA60-0AA0 - 2000 mm, can be cut to length 6ES7 194-4GA20-0AA0 11 • Compact-narrow, for interface, electronics and power modules - 500 mm 6ES7 194-4GC70-0AA0 - 1000 mm 6ES7 194-4GC60-0AA0 - 2000 mm, can be cut to length 6ES7 194-4GC20-0AA0 Spare fuse 12.5 A fast-blow, for interface and power modules, 10 units per pack 6ES7 194-4HB00-0AA0 B) Subject to export regulations: AL: N, ECCN: EAR99H The connection module for the IM 154-2 DP High Feature interface module (to be ordered separately) is available in three different connection versions: • CM IM DP direct • CM IM DP ECOFAST Cu • CM IM DP M12 7/8" The PROFIBUS address can be set on the connection module per DIL switch. The segmenting terminating resistor can be connected using a further DIL switch. Siemens ST PCS 7 · November 2007 11/59 © Siemens AG 2007 Process I/O Dezentrale Peripherie ET 200pro Digital electronics modules EM 141, EM 142 ■ Overview ■ Selection and Ordering Data Order No. Digital electronics modules Digital input modules 6ES7 141-4BF00-0AB0 B) 6ES7 142-4BD00-0AB0 B) Connection module CM IO 4 x M12 4 M12 sockets for connecting digital or analog sensors/actuators to ET 200pro 6ES7 194-4CA00-0AA0 B) Connection module CM IO 8 x M12 8 M12 sockets for connecting digital sensors/actuators to ET 200pro 6ES7 194-4CB00-0AA0 B) Module labels for color-coded identification of the CM IOs in white, red, blue and green; pack with 100 units of each color 6ES7 194-4HA00-0AA0 Digital input module 8 DI High Feature 24 V DC, with channel diagnostics, including bus module. Connection module must be ordered separately Digital output modules Digital output module 4 DO High Feature 24 V DC, 2 A, with channel diagnostics, including bus module. Connection module must be ordered separately Accessories The following digital electronics modules can be used for connecting actuators/sensors in the context of SIMATIC PCS 7: Digital input modules • EM 8 DI DC 24 V High Feature - Digital electronics module with eight inputs - Suitable for standard switches and proximity switches (BEROs) - Rated input voltage 24 V DC - Diagnostics "Short-circuit of sensor supply to ground" per channel - Diagnostics "Open-circuit" per channel - Process alarm - Parameterizable input delay 11 Digital output modules • EM 4 DO DC 24 V; 2 High Feature - Digital electronics module with four outputs - Suitable for solenoid valves, DC contactors and indicator lights - Output current 2 A per output - Rated load voltage 24 V DC - Diagnostics "Short-circuit of outputs to ground" per channel - Diagnostics "Short-circuit of outputs to P" per channel - Diagnostics "Open-circuit in outputs" per channel - Diagnostics "Load voltage missing" per module - Parameterizable substitute value ■ Technical specifications For detailed technical specifications of the digital electronics modules, see: • Catalog IK PI • Mall/CA 01 under "Distributed I/Os / ET 200pro" 11/60 Siemens ST PCS 7 · November 2007 Further accessories For plugs, cables and further accessories, see Catalog IK PI or Mall/CA 01 under "Distributed I/O / ET 200pro" B) Subject to export regulations: AL: N, ECCN: EAR99H ■ Accessories Connection modules Actuators and sensors are connected using commercially-available 5-contact M12 plugs on the connection module. The connection module is plugged onto the electronics module, and screwed to the latter. The following connection modules (to be ordered separately) are available for the above-mentioned electronics modules: • CM IO 4x M12 (for EM DI and EM DO) • CM IO 8x M12 (for EM DI) Depending on the selected connection module, each plug for the 8-channel digital input module has one or two channels: • 4 x M12 round plug connections with 2 channels per plug (double assignment) • 8 x M12 round plug connections with 1 channel per plug (single assignment) © Siemens AG 2007 Process I/O Dezentrale Peripherie ET 200pro Analog electronics modules EM 144, EM 145 ■ Overview EM 4 AI RTD High Feature • 4 inputs for isolated (floating) resistance measurements or resistance thermometers with 2-, 3- and 4-wire connections • Input ranges: - Resistance measurement: 150 Ω; 300 Ω; 600 Ω; 3000 Ω; resolution 15 bit - Resistance thermometer: Pt100; Ni100; Ni120; Pt200; Ni200; Pt500; Ni500; Pt1000; Ni1000; resolution 15 bit + sign • Automatic compensation of line resistances with 3- and 4-wire connections • Parameterizable temperature coefficient with resistance-type sensors • Electrically isolated from load voltage supply 1L+ and 2L+ • Linearization of sensor characteristics • Diagnostics "Open-circuit" per channel (terminals 1 and 3 are monitored for open-circuit) • Permissible common-mode voltage 10 Vpp AC Analog output modules The following analog electronics modules can be used for connecting actuators/sensors in the context of SIMATIC PCS 7: Analog input modules EM 4 AI U High Feature • 4 inputs for voltage measurements • Input ranges: - ± 10 V, resolution 15 bit + sign - ± 5 V, resolution 15 bit + sign - 0 to 10 V, resolution 15 bit - 1 to 5 V, resolution 15 bit • Electrically isolated from load voltage 2L+ • Diagnostics "Short-circuit of sensor supply to M" per module • Diagnostics "Short-circuit, open-circuit" per channel (depending on measuring range) • Process interrupt with limit violation on channel 0 • Permissible common-mode voltage 5 Vpp AC EM 4 AI I High Feature • 4 inputs for current measurements • Input ranges: - ± 20 mA, resolution 15 bit + sign - 0 to 20 mA, resolution 15 bit - 4 to 20 mA, resolution 15 bit • Two-wire and four-wire transmitters can be connected • Electrically isolated from load voltage 2L+ • Diagnostics "Short-circuit of sensor supply to M" per module • Diagnostics "Short-circuit, open-circuit" per channel (depending on measuring range) • Process interrupt with limit violation on channel 0 • Permissible common-mode voltage 5 Vpp AC EM 4 AO U High Feature • 4 outputs for voltage output • Output ranges: - ± 10 V, resolution 15 bit + sign - 1 to 5 V, resolution 14 bit - 0 to 10 V, resolution 15 bit • Electrically isolated from sensor supply voltage 1L+ • Diagnostics "Short-circuit of sensor supply to M" per module • Diagnostics "Open-circuit in outputs" per channel • Substitute value output EM 4 AO I High Feature • 4 outputs for current output • Output ranges: - ± 20 mA, resolution 15 bit + sign - 4 to 20 mA, resolution 14 bit - 0 to 20 mA, resolution 15 bit • Electrically isolated from sensor supply voltage 1L+ • Diagnostics "Short-circuit of sensor supply to M" per module • Diagnostics "Open-circuit" per channel • Substitute value output ■ Technical specifications For detailed technical specifications of the analog electronics modules, see: • Catalog IK PI • Mall/CA 01 under "Distributed I/Os / ET 200pro" Siemens ST PCS 7 · November 2007 11/61 11 © Siemens AG 2007 Process I/O Dezentrale Peripherie ET 200pro Analog electronics modules EM 144, EM 145 ■ Selection and Ordering Data ■ Accessories Order No. Analog electronics modules Connection modules Analog input modules Analog input module 4 AI U High Feature, ±10 V; ±5 V; 0 to 10 V; 1 to 5 V, channel diagnostics, including bus module. Connection module must be ordered separately 6ES7 144-4FF00-0AB0 B) Analog input module 4 AI I High Feature, ±20 mA; 0 to 20 mA; 4 to 20 mA, channel diagnostics, including bus module. Connection module must be ordered separately 6ES7 144-4GF00-0AB0 B) Analog input module 4 AI RTD High Feature; resistances: 150, 300, 600 and 3000 Ohm; resistance thermometers: Pt100, 200, 500, 1000, Ni100, 120, 200, 500 and 1000; channel diagnostics, including bus module. Connection module must be ordered separately 6ES7 144-4JF00-0AB0 B) Analog output module 4 AO U High Feature, ±10 V; 0 to 10 V; 1 to 5 V, channel diagnostics, including bus module. Connection module must be ordered separately 6ES7 145-4FF00-0AB0 B) Analog output module 4 AO I High Feature, ±20 mA; 0 to 20 mA; 4 to 20 mA, channel diagnostics, including bus module. Connection module must be ordered separately 6ES7 145-4GF00-0AB0 B) Connection module CM IO 4 x M12 4 M12 sockets for connecting digital or analog sensors/actuators to ET 200pro 6ES7 194-4CA00-0AA0 B) Module labels for color-coded identification of the CM IOs in white, red, blue and green; pack with 100 units of each color 6ES7 194-4HA00-0AA0 Analog output modules Accessories 11 Further accessories For plugs, cables and further accessories, see Catalog IK PI or Mall/CA 01 under "Distributed I/O / ET 200pro" B) Subject to export regulations: AL: N, ECCN: EAR99H 11/62 Siemens ST PCS 7 · November 2007 Actuators and sensors are connected using commercially-available 5-contact M12 plugs on the connection module. The connection module is plugged onto the electronics module, and screwed to the latter. The connection module CM IO 4 x M12 (to be ordered separately) is available for the above-mentioned electronics modules: © Siemens AG 2007 Process I/O Dezentrale Peripherie ET 200pro Safety-related electronics modules ■ Overview • Group fault display (SF; red LED) • Fault display for each sensor power supply (Vs1F to Vs2F) is output on the VsF LED and the associated channels • Status and fault displays per input/output (dual-color green/red LED) • Identification data • Parameterizable diagnostics • Achievable safety class SIL 3 • Can only be operated in safety mode ■ Technical specifications For detailed technical specifications of the safety-related electronics modules, see: • Catalog IK PI • Mall/CA 01 under "Distributed I/Os / ET 200pro" In combination with the safety-related automation systems of the SIMATIC PCS 7 process control system, the safety-related electronics modules of SIMATIC ET 200pro can be used to implement safety applications. The safety-related digital inputs record the signal statuses from safety-related sensors, and generate corresponding safety telegrams for the automation system. Depending on the safety telegrams of the automation system, the safety-related digital outputs trigger safe shut-down procedures. They are also responsible for monitoring short-circuits and cross-circuits up to the actuator. The safe communication with the automation systems is carried out over PROFIBUS with PROFIsafe. All modules are certified up to SIL 3 (IEC 61508) and Cat. 4 (EN954-1). The following modules are available: Safety-related digital input module EM 8/16 F-DI PROFIsafe • 16 inputs (SIL2/Cat.3) or 8 inputs (SIL3/Cat.3 or Cat.4) • Suitable for standard switches and 3/4-wire proximity switches (BEROs) • Rated input voltage 24 V DC • 4 short-circuit-proof sensor supplies for 4 inputs each • External sensor power supply possible • Group fault display (SF; red LED) • Fault display for each sensor power supply (Vs1F to Vs4F) is output on the VsF LED and the associated channels • Status and fault displays per input (dual-color green/red LED) • Identification data • Parameterizable diagnostics • Can only be operated in safety mode 11 Safety-related digital input/output module EM 4/8 F-DI, 4 F-DO 2 A • Inputs - 8 inputs (SIL 2/Cat. 3) or 4 inputs (SIL 3/Cat. 3 or Cat. 4) - Suitable for standard switches and 3/4-wire proximity switches (BEROs) - Rated input voltage 24 V DC - 2 short-circuit-proof sensor supplies for 4 inputs each - External sensor power supply possible • Outputs - 4 outputs, current sourcing/sinking - Output current 2 A - Rated load voltage 24 V DC - Suitable for solenoid valves, DC contactors and indicator lights Siemens ST PCS 7 · November 2007 11/63 © Siemens AG 2007 Process I/O Dezentrale Peripherie ET 200pro Safety-related electronics modules ■ Selection and Ordering Data ■ Accessories Order No. Safety-related electronics modules Connection modules Safety-related digital input module Actuators and sensors are connected using commercially-available 5-contact M12 plugs on the connection module. The connection module is plugged onto the electronics module, and screwed to the latter. One of the following connection modules (to be ordered separately) is required for each of the abovementioned electronics modules: • Connection module CM IO 16 x M12 for the electronics module 8/16 F-DI, 24 V DC/2 A • Connection module CM IO 12 x M12 for the electronics module 4/8 F-DI/4 F DO, 24 V DC/2 A 6ES7 148-4FA00-0AB0 B) 6ES7 148-4FC00-0AB0 B) • CM IO 16 x M12 for the electronics module 8/16 F-DI, 24 V DC/2 A 6ES7 194-4DD00-0AA0 B) • CM IO 12 x M12 for the electronics module 4/8 F-DI/4 F DO, 24 V DC/2 A 6ES7 194-4DC00-0AA0 B) Safety-related digital input module 8/16 F-DI PROFIsafe 24 V DC, including bus module. Connection module must be ordered separately Safety-related digital input/output module Safety-related digital input/output module 4/8 F-DI, 4 F-DO 2 A 24 V DC, including bus module. Connection module must be ordered separately Accessories Connection module Further accessories For plugs, cables and further accessories, see Catalog IK PI or Mall/CA 01 under "Distributed I/O/ ET 200pro" B) Subject to export regulations: AL: N, ECCN: EAR99H 11 11/64 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Process I/O Dezentrale Peripherie ET 200pro Power module PM-E ■ Overview ■ Selection and Ordering Data Order No. Power module 6ES7148-4CA00-0AA0 B) • Connection module CM PM-E ECOFAST for supply of 24 V DC load voltage, 1 ECOFAST Cu connection 6ES7 194-4BA00-0AA0 B) • Connection module CM PM-E direct for supply of 24 V DC load voltage, up to two M20 cable glands 6ES7 194-4BC00-0AA0 B) • Connection module CM PM-E 7/8" for supply of 24 V DC load voltage, 1 x 7/8" 6ES7 194-4BD00-0AA0 B) Spare fuse 12.5 A fast-blow, for interface and power modules, 10 units per pack 6ES7 194-4HB00-0AA0 Power module PM-E DC 24 V For generating 24 V DC load voltage groups for electronics modules within an ET 200pro station. Accessories Connection modules for power module The power module PM-E DC 24 V is used within an ET 200pro station when generating 24 V DC load voltage groups for electronics modules. You can position power modules in an ET 200pro station anywhere to the right of the interface module. The first power module is already integrated in the interface module. Each power module which you install in the ET 200pro station interrupts the load voltage busbar, and opens up a new potential group (common potential) for the load voltage supply 2L+. All subsequent load voltages of the electronics modules are fed from this power module. Each power module has a replaceable fuse for protecting the device. Only line protection according to DIN VDE 0100 need be provided externally in addition. The electronics/sensor supply 1L+ is not interrupted by the power module, it is looped through. The power module is fitted on the associated bus module when delivered. ■ Technical specifications For detailed technical specifications of the power module PM-E, see: • Catalog IK PI • Mall/CA 01 under "Distributed I/Os / ET 200pro" Further accessories For plugs, cables and further accessories, see Catalog IK PI or Mall/CA 01 under "Distributed I/O / ET 200pro" B) Subject to export regulations: AL: N, ECCN: EAR99H ■ Accessories Connection module The connection module for the power module PM-E is used to connect the load voltage 2L+. It is fitted on the power module. The module must be ordered separately, and is available with the following types of connection: • CM PM-E direct • CM PM-E ECOFAST • CM PM-E 7/8" Siemens ST PCS 7 · November 2007 11/65 11 © Siemens AG 2007 Process I/O 11 11/66 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 IT world 12/2 SIMATIC IT Siemens ST PCS 7 · November 2007 © Siemens AG 2007 IT world SIMATIC IT ■ Overview ■ Design SIMATIC IT consists of various components designed for different tasks which can all be coordinated by the SIMATIC IT Production Modeler. The basic functions are implemented using SIMATIC IT components. These are available in the form of the following product bundles: • SIMATIC IT Plant Intelligence (formally known as MIS - Management Information System) Defines key performance indicators conforming to the plant model. SIMATIC IT Plant Intelligence allows realistic assessment of the plant performance. • SIMATIC IT Genealogy Management For materials management in the entire company, taking into account the legal terms and conditions. Typical tasks are reverse and forwards genealogy, fundamental material monitoring, and synchronization of material master data with the ERP system. • SIMATIC IT Order Management For job management from planning to execution, including scheduling, materials planning, new planning of sequence, monitoring and recording of execution. Further bundles are available, e.g. SIMATIC IT Basic Tracking & Tracing, SIMATIC IT Basic Production Management or SIMATIC IT Production Suite, providing a fully-scaled product portfolio. Integration and synchronization of all business processes with SIMATIC IT In order to remain competitive, manufacturers must shorten their product launch times, increase production transparency and flexibility, optimize planning and scheduling, and reduce waste, storage costs and downtimes. At the same time, directives and high-quality standards must be observed in the global production locations, and maximum productivity and optimum costs must be guaranteed. Manufacturing Execution Systeme (MES), such as SIMATIC IT from Siemens, permit effective integration of product processes and material management systems, and support the coordination of all equipment and applications relevant to production during all phases. 12 SIMATIC IT can be used to model the complete production know-how, to precisely define the operating processes, and to record data in real-time from the ERP and production levels. It is then possible to control corporate processes more effectively, to minimize downtimes, production waste and postprocessing, to optimize stockkeeping, and to react rapidly and flexibly to changing customer requirements. Production Suite Basic Production Management Order Management Order Management Basic Tracking & Tracing Genealogy Management Material Management MIS Data Management Historian Summary of SIMATIC IT bundles Each of these product bundles contains the optional SIMATIC IT Client Application Builder (CAB) which provides the GUI for the MES applications in a complete Web-based environment. Patented functions for optimization of image updating are available based on standard technology. The SIMATIC IT Client Application Builder offers complete support for operator stations which require practically no administrative overhead (so-called zero administration cost clients). 12/2 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 IT world SIMATIC IT Additional options can be separately purchased for each bundle: • SIMATIC IT PDS-I (Predictive Detailed Scheduler - Interactive) is the detailed scheduling component of SIMATIC IT. It coordinates and processes the job list coming from the ERP (Enterprise Resources Planning) or APS (Advanced Planning System) with consideration of all available resources in real-time. An advanced, dedicated interface even allows users who have no IT or scheduling experience to produce optimum production job planning. A number of predefined steps additionally support users in selection of the best planning scenario. • SIMATIC IT Report Manager offers comprehensive reporting functions. It provides valuable knowledge concerning the company and supports users in complying with statutory requirements for ad hoc reporting (e.g. EU directive EC 178/2002 for Europe, US bioterrorism act for North America). • SIMATIC IT OEE-DTM Option (Overall Equipment Efficiency / Down Time Management) offers support for the dedicated configuration for downtime management and efficient utilization of the overall equipment through various predefined KPIs for evaluation of performance and efficiency. It also allows customized performance calculations as well as real and consistent efficiency analysis using graphic objects. Thanks to integration within the complete SIMATIC IT infrastructure, it supports the implementation of corrective and/or preventive actions for avoiding reductions in quality. • SIMATIC IT SPC (Statistical Process Control) is used for the dedicated configuration of statistical process control through various predefined KPIs for evaluation with the most common control charts (e.g. Nelson and Western Electric). It also allows customized KPI calculations as well as consistent statistical analyses with application of graphic objects. Thanks to integration within the complete SIMATIC IT infrastructure, it supports the implementation of corrective and/or preventive actions for avoiding reductions in quality. The MES product range of SIMATIC IT is completed by the following components for special ISA-95 functions (also offered as stand-alone products): • SIMATIC IT Unilab Laboratory Information System / Laboratory Information Management System (LIMS) for management and control of laboratory data and processes. • SIMATIC IT Interspec Specifications Management System for support of product lifecycle / Product Lifecycle Management (PLM) for management and control of production specifications in the entire company. • SIMATIC IT XHQ provides decision-makers in a company with a tool for making better, faster and more sound decisions at all levels through the assistance of role-based Web views, thus increasing the company’s total performance. This allows manufacturers to positively influence the production result through early and qualified decisions concerning the production sequence. As a result of the complete overview of all critical business and operating data from various sources within the company, operators and managers are able to check the true performance compared to corporate targets. SIMATIC IT XHQ is initially focused on the chemical and oil & gas industries. ■ Function SIMATIC IT from Siemens offers significant advantages. The model of the business and production processes is transparent, understandable, and independent of the control systems. Even complex business and production processes are easy to model. Subsequent modifications can be incorporated efficiently and without problem. Modeling of the business and production processes with SIMATIC IT allows complete documentation as well as effective protection of know-how. The plant and production models can be saved in libraries, and then used again in other projects. In this manner, they can be used at any company location for standardization of procedures. Best practices are therefore available everywhere. This prevents implementation errors, provides investment safeguarding, reduces launch and maintenance costs, and results in a significant shortening in the project duration. The product architecture and functionality of SIMATIC IT are in conformance with ISA-95, the internationally recognized standard for Manufacturing Execution Systems and Manufacturing Operation Management. ■ Integration Integration of SIMATIC IT and SIMATIC PCS 7 The Product Integration Pack is available for joint projects with SIMATIC IT und SIMATIC PCS 7, and includes two data media (one each for the two target systems SIMATIC IT and SIMATIC PCS 7). These contain the software updates required for integrated configurations. A user manual is also enclosed which provides information and important notes for persons planning, developing and implementing integration projects. The integration pack can be obtained using the SIMATIC IT purchasing methods. ■ More information Contact partners Marketing Germany Andreas Kempenich E-mail: andreas.kempenich@siemens.com Europe Helpline: +49 (0) 180 5050 111 Siemens Automation and Drives Automation Solutions MES Viale Cembrano, 11 I-16148 Genua, Italy Tel.: +39 010 3434-1 Fax: +39 010 383 115 E-mail: marketing.simatic-it@siemens.com 12 Additional information is available in the Internet under: http://www.siemens.com/simatic-it Siemens ST PCS 7 · November 2007 12/3 © Siemens AG 2007 IT world 12 12/4 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Migration to SIMATIC PCS 7 13/2 Introduction Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Migration to SIMATIC PCS 7 Introduction ■ Overview Migration strategy Siemens migration strategy System aspects Plant aspects Production aspects HMI/batch - Replaces old HMI - Replaces batch system Innovation pressure - Improved process control - IT integration - Advanced process control & asset management Strategy - Plant/product future - Planned modernization (revamping) Lifecycle phases - Maintenance & modernization - Expansion & improvement - Renewal/replacement with state-of-the-art technology Time-to-Market - Production time - Available downtime Controller/network - Replaces controller - Gateway to SIMATIC PCS 7 I/O field connection - Further use of I/Os - Field connection elements for SIMATIC PCS 7 Step-by-step Cost reduction - Maintenance budget - Investment budget Adaptable Innovative technologies 13 13/2 Siemens ST PCS 7 · November 2007 Flexible Globalization and incessantly increasing competitive pressures are forcing companies to continuously increase productivity and shorten product time to market. To this end, it is necessary to continuously optimize engineering procedures and the process, and to simultaneously consider new industrial requirements and directives. Today, many systems and plants must be expanded and modernized to ensure that companies can continue to provide products meeting market requirements. However, since the installed basis of hardware, application software and know-how of the operating and maintenance engineers represents an enormous value, the safeguarding of investments for companies operating the plants is always assigned a high priority during all modernization plans. Experience has shown that the success of migration is largely determined by providing a technical solution that optimally matches the customer requirements and the customer’s plant. Minimization of the technical and financial risks together with safeguarding of investments for as long a period as possible are always fundamental aspects. The different lifecycles of the various system components must also be considered, which currently vary from 5 years for PC-based workstations, 15 years for controllers, up to 25 years or more for input/output components and wiring. Therefore Siemens does not consider its task to simply be the complete replacement of an existing system, but in close collaboration together with customers and their system integrators of an individual, future-oriented solution based on the state-of-the-art SIMATIC PCS 7 process control system - always under the directives: 7 Step-by-step system innovation 7 Adaptable to the specific conditions of the plant 7 Flexible according to production requirements © Siemens AG 2007 Migration to SIMATIC PCS 7 Introduction ■ Function Portfolio of the migration products Early on Siemens recognized the significance of migration for process automation, and for many years has offered a wide range of innovative migration products and solutions for its globally proven systems. Right from the beginning, the maxim of Siemens’ migration strategy is to modernize the existing installed basis in steps without completely changing the system; and where possible without or with minimal plant downtime. Siemens has the products to support customers’ endeavors to achieve long-term safeguarding of investments together with maximization of their return on assets, even for legacy systems from other vendors. Siemens’ know-how in the migration sector has continuously grown as time has passed. The experience gained in numerous migration projects has been incorporated into new products and technologies which are even more efficient. For example, "Database Automation" (DBA) is available for engineering of operation and monitoring systems. Using DBA and a plug-in interface, it is possible to download the configuration data, and to display and configure them using a standardized user interface. DBA allows system-based migration of operator system data from different output systems in standardized form, thus providing uniform software quality, security and understandability. The migration products can be categorized as follows: SIMATIC IT Legacy system SIMATIC PCS 7 Engineering Station Controller Importing of engineering data of old OS OS replacement by server for PCS 7/OS Importing of controller engineering Server Gateway Engineering System Server Gateway to data coupling S7-400 S, H, HF controller PROFIBUS PA I/O Wiring rack Linking of existing I/O modules to PCS 7/AS I/O interface Field Termination Adapter PROFIBUS DP Migration services in every step of migration project HMI Clients Motor ET 200M Step-by-step migration with the right products and services Migration component Description OS migration products • Interface from SIMATIC PCS 7 OS Server to system bus of legacy system • OS conversion tool (e.g. DBA) • Faceplate library Services for OS migration Tools/services for conversion of process displays Services for AS migration Tools/services for function-based conversion of AS engineering data to SIMATIC PCS 7 BATCH migration components Enables existing system to use SIMATIC BATCH Gateway • Gateway between system bus of legacy system and SIMATIC PCS 7 (mainly for AS-AS communication) • Engineering tool for gateway Reuse of legacy system I/Os or Field Termination Assembly (FTA) • Reuse of I/Os (connection of old I/Os to SIMATIC PCS 7 automation systems, mostly for Siemens systems) • Field Termination Assemblies (FTAs) for field cabling Siemens ST PCS 7 · November 2007 13 13/3 © Siemens AG 2007 Migration to SIMATIC PCS 7 Introduction Typical migration scenarios Scenario 3: Comprehensive modernization The migration path that a user takes depends on the specific technical and economical factors of each migration project. The migration products offer the modularity and flexibility required to implement different scenarios. The following are typical migration scenarios which can be implemented using these migration products: Bottlenecks in the provision of spare parts, insufficient support, and the necessity for functional expansions (e.g. fieldbus technology or IT integration) can also force comprehensive modernization of the old system using the future-oriented SIMATIC PCS 7 process control system. Conversion may also be possible during operation. Further use of the existing I/O level is supported, and the investments made for wiring, hardware components or application engineering are safeguarded. Scenario 1: Replacement of existing HMI system by a SIMATIC PCS 7 operator system If the HMI (Human Machine Interface) system is technically obsolete, if the stocking of spare parts is too expensive, if it no longer complies with current directives and standards for operator workstations, or if functional expansions are required (e.g. IT integration), it is possible to simply replace the existing HMI system by a SIMATIC PCS 7 operator system. The controller with application software and the process I/O are retained. The benefits of these migration step are: • Minimum costs • Clear risk • Lengthening of service life of complete plant • New application possibilities • Opening of system for IT world Scenario 2: Expansion of existing plant The existing plant is initially retained, and is modernized by expanding with further sections/units with SIMATIC PCS 7. The benefits of these migration step are: • Simple, step-by-step increase in production capacity • Clear risk • Introduction of new technologies (e.g. PROFIBUS fieldbus, HMI) • Opening of system for IT world • Together with scenario 1, enables process control using a uniform operator system 13 13/4 Siemens ST PCS 7 · November 2007 The benefits of these migration step are: • Increase in performance • Introduction of new technologies (e.g. PROFIBUS fieldbus, HMI) • Opening of system for IT world • Lengthening of service life of complete plant • Reduction in number of system suppliers • Elimination of bottlenecks © Siemens AG 2007 Migration to SIMATIC PCS 7 Introduction SIMATIC PCS 7 OS clients PCS 7/TM OS PCS 7/ APACS+ OS ES CS 275 PCS 7/505 OS 4-mation MBUS SIMATIC PCS 7 Engineering APT H1 TF PCS 7/ OPMC OS PCS 7 OS server SIMATIC PCS 7 OS clients PCS 7/90 OS SIMATIC IT Management Console PCS 7/F2K OS PCS 7/PVX OS Control Builder F Envox Ethernet PCS 7/ third-party OS Data Highway S7417H AC 800F OpenPMC Controller S7-41x Bailey Plant Loop/ INFI-NET SIMATIC PCS 7 Bailey Infi/Net 90 PROVOX Controller and I/O Third-party control system AS 235 TELEPERM M APACS+/ QUADLOG SIMATIC 505 OpenPMC ABB Freelance Emerson PROVOX Other systems Migration spectrum Migration Support Center The migration of our own process control systems to SIMATIC PCS 7 is a matter of course for Siemens, and a significant component of the continued supplier/customer relationship. Siemens is additionally able to offer migration solutions for process control systems from other vendors, e.g. for systems from ABB, Honeywell or Emerson. Siemens has established several global Migration Support Centers which offer customers further support for migration projects in addition to product support: • Migration concepts • Quotation preparation • Engineering/project management Siemens can work closely with the customer’s system integrators when implementing migration projects, for they have the knowhow gained over many years of working with the user and exactly know the plant as well as the customer’s requirements. This partnership is a guarantee for the companies operating plants that they will receive an optimum migration solution. A further important aspect is that Siemens supports the migration products as well as the standard products by means of product updating and customer support. A special strength of Siemens compared to other suppliers of migration solutions is the ability to offer customers long-term support through know-how, servicing and provision of components, spare parts and upgrades. With the future-oriented SIMATIC PCS 7 process control system, innovative migration solutions and services, many years of know-how in process automation and migration, as well as continuous worldwide servicing, Siemens demonstrates its expertise and offers the security of a reliable partner. Development of further migration products and tools Through the development of flexible migration solutions and services, comprehensive sector know-how, migration experience developed over many years, and worldwide support, Siemens has laid the foundation for the development of migration solutions for third-party control systems. This allows users of thirdparty control systems to take advantage of the globally leading SIMATIC technology in order to safeguard their investments in new automation technology for the future. ■ More information For further information, see the Chapter “Additional migration products and solutions”. 13 Siemens ST PCS 7 · November 2007 13/5 © Siemens AG 2007 Migration to SIMATIC PCS 7 13 13/6 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Ordering data for previous version SIMATIC PCS 7 V6.1 14/2 Basic hardware V6.1 14/4 Starter systems V6.1 14/5 ES software V6.1 14/9 OS software V6.1 14/13 SIMATIC BATCH Software V6.1 14/14 Route Control Software V6.1 14/15 Asset Management Software V6.1 14/16 PROFIBUS PA components 14/17 Automation systems Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Ordering data for previous version SIMATIC PCS 7 V6.1 Basic hardware V6.1 ■ Selection and Ordering Data ■ Selection and Ordering Data Order No. Single station Server SIMATIC PC in rack of 19" design, Pentium 4 3.4 GHz, 1 GB RAM (2 x 512 MB), sound, SATA-RAID 1 with 2 hard disks of 120 GB, graphics controller on board with dynamic video memory, DVD writer DVD±RW IDE, 3.5" diskette drive, optical mouse, FastEthernet RJ45 on board for connection to OS-LAN, without monitor, keyboard and printer, SIMATIC PCS 7 software preinstalled and 2 restore DVDs SIMATIC PC in rack of 19" design, Pentium 4 3.4 GHz, 1 GB RAM (2 x 512 MB), sound, SATA-RAID 1 with 2 hard disks of 120 GB, graphics controller on board with dynamic video memory, DVDROM IDE, 3.5" diskette drive, optical mouse, FastEthernet RJ45 on board for connection to OS-LAN, without monitor, keyboard and printer, SIMATIC PCS 7 software preinstalled and 2 restore DVDs Windows 2000 Professional MUI operating system (German, English, French, Italian, Spanish, Chinese, Japanese) Windows 2000 Server MUI operating system (German, English, French, Italian, Spanish, Chinese, Japanese) Order No. • SIMATIC PCS 7 ES/OS IL43 BCE W2K Connection to plant bus through Basic Communication Ethernet (BCE) with FastEthernet RJ45 network card (PCI card) 6ES7 650-0LC16-0YX0 D) • SIMATIC PCS 7 OS Server IL43 BCE W2K Connection to plant bus through Basic Communication Ethernet (BCE) with FastEthernet RJ45 network card (PCI card) 6ES7 650-0LE16-0YX0 D) • SIMATIC PCS 7 ES/OS IL43 IE W2K Connection to plant bus via Industrial Ethernet with CP 1613 A2 communications processor 6ES7 650-0LC16-0YX1 D) • SIMATIC PCS 7 OS Server IL43 IE W2K Connection to plant bus via Industrial Ethernet with CP 1613 A2 communications processor 6ES7 650-0LE16-0YX1 D) • SIMATIC PCS 7 OS Server IL43 BCE SRV03 Connection to plant bus through Basic Communication Ethernet (BCE) with FastEthernet RJ45 network card (PCI card) 6ES7 650-0LH16-0YX0 D) • SIMATIC PCS 7 OS Server IL43 IE SRV03 Connection to plant bus via Industrial Ethernet with CP 1613 A2 communications processor 6ES7 650-0LH16-0YX1 D) Windows XP Professional MUI operating system (German, English, French, Italian, Spanish, Chinese, Japanese) • SIMATIC PCS 7 ES/OS IL43 BCE WXP Connection to plant bus through Basic Communication Ethernet (BCE) with FastEthernet RJ45 network card (PCI card) 6ES7 650-0LF16-0YX0 • SIMATIC PCS 7 ES/OS IL43 IE WXP Connection to plant bus via Industrial Ethernet with CP 1613 A2 communications processor 6ES7 650-0LF16-0YX1 D) D) Windows Server 2003 MUI operating system (German, English, French, Italian, Spanish, Chinese, Japanese) D) Subject to export regulations: AL: N, ECCN: 5D992B1 14 14/2 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Ordering data for previous version SIMATIC PCS 7 V6.1 Basic hardware V6.1 ■ Selection and Ordering Data ■ Selection and Ordering Data Order No. Order No. Client Additional and expansion components SIMATIC PC in rack of 19" design, Pentium 4 3.4 GHz, 512 MB RAM (2 x 256 MB), SATA hard disk 120 GB, graphics controller on board with dynamic video memory, DVD-ROM IDE, 3.5" diskette drive, optical mouse, FastEthernet RJ45 on board for connection to OS-LAN, without monitor, keyboard and printer, SIMATIC PCS 7 preinstalled and 2 restore DVDs Memory modules for expanding the main memory B) • 1 GB memory expansion kit for SIMATIC Rack PC IL 43 (2 x 512 MB) for dual channel 6ES7 648-2AF40-0GB0 B) • 2 GB memory expansion kit for SIMATIC Rack PC IL 43 (2 x 1 GB) for dual channel 6ES7 648-2AF50-0GB0 B) • International key assignment 6ES7 650-0LD16-0YX0 D) 6ES7 648-0CB00-0YA0 Tower kit for SIMATIC PCS 7 Industrial Workstations based on Rack PC 547B and IL 43 • Tower kit for conversion of a Rack PC into an industrial Tower PC Windows XP Professional MUI operating system (German, English, French, Italian, Spanish, Chinese, Japanese) • SIMATIC PCS 7 OS Client IL43 WXP 6ES7 648-2AF30-0GB0 SIMATIC PC keyboard (USB connection) Windows 2000 Professional MUI operating system (German, English, French, Italian, Spanish, Chinese, Japanese) • SIMATIC PCS 7 OS Client IL43 W2K • 512 MB memory expansion kit for SIMATIC Rack PC IL 43 (2 x 256 MB) for dual channel 6ES7 648-1AA00-0XC0 3-m power cable for Rack PC 1) 6ES7 650-0LG16-0YX0 D) • For Great Britain 6ES7 900-0BA00-0XA0 • For Switzerland 6ES7 900-0CA00-0XA0 • For USA 6ES7 900-0DA00-0XA0 • For Italy 6ES7 900-0EA00-0XA0 B) Subject to export regulations: AL: N, ECCN: EAR99H D) Subject to export regulations: AL: N, ECCN: 5D992B1 1) The PCS 7 systems are delivered as standard with a "European power cable". The country-specific versions listed above are required for some countries. 14 Siemens ST PCS 7 · November 2007 14/3 © Siemens AG 2007 Ordering data for previous version SIMATIC PCS 7 V6.1 Starter systems V6.1 SIMATIC PCS 7 BOX ■ Selection and Ordering Data PCS 7 Basic Package ■ Selection and Ordering Data Order No. SIMATIC PCS 7 BOX complete system (ES, OS and AS) assembled and preinstalled, comprising: • SIMATIC Box PC 627, 24 V DC, with WinAC Slot 416 and Windows XP Professional MUI (German, English, French, Italian, Spanish) • Memory card 2 MB • Backup battery • Mouse • SIMATIC PCS 7 Engineering Software V6.1 for AS/OS, 250 POs/RC 8K, 3 languages (German, English, French), floating license for 1 user • PCS 7 Library Blocks V6.1, 3 languages (German, English, French), runtime license for 1 automation system 6ES7 650-2MA16-0YX0 D) SIMATIC PCS 7 BOX runtime system (OS and AS) assembled and preinstalled, comprising: • SIMATIC Box PC 627, 24 V DC, with WinAC Slot 416 and Windows XP Professional MUI (German, English, French, Italian, Spanish) • Memory card 2 MB • Backup battery • Mouse • SIMATIC PCS 7 OS Software Single Station V6.1, 250 POs/RT 8 K, 3 languages (German, English, French), single license for 1 installation • PCS 7 Library Blocks V6.1, 3 languages (German, English, French), runtime license for 1 automation system 6ES7 650-2MB16-0YX0 D) 14 14/4 Siemens ST PCS 7 · November 2007 PCS 7 Basic Package V6.1 comprising: • 1 x AS 416-3 with - PS 407 power supply; 10 A for 120/230 V AC/DC - UR2 rack (9 slots) - Memory card 8 MB - CP 443-1EX11 - CP443-5 Extended • 1 x engineering station with - Basic device SIMATIC PCS 7 ES/OS IL 43 BCE WXP - PCS 7 engineering software for AS/OS; 1000 POs/RC 32K, floating license - SFC Visualization, floating license - PCS 7 Import/Export Assistant, floating license - SIMATIC PDM PCS 7, floating license • 1 x OS Single Station - Basic device SIMATIC PCS 7 ES/OS IL 43 BCE WXP - PCS 7 OS Software Single Station for 1000 POs/RT 32K, single license - SFC Visualization, floating license Order No. 6ES7 650-3GD16-0YX0 D) Subject to export regulations: AL: N, ECCN: 5D992B1 D) © Siemens AG 2007 Ordering data for previous version SIMATIC PCS 7 V6.1 ES software V6.1 Standard engineering software ■ Selection and Ordering Data Order No. ■ Selection and Ordering Data Order No. SIMATIC PCS 7 Engineering Software V6.1 3 languages (German, English, French), executes with Windows 2000 Professional/ 2000 Server or Windows XP Professional/ Server 2003, floating license for 1 user Electronic documentation on PCS 7 toolset DVD Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions; PCS 7 V6.1 toolset DVD, Microsoft SQL Server including EULA, PC Anywhere Host and supplementary CDs/DVDs (e.g. Microsoft ServicePacks and tools) SIMATIC PCS 7 PowerPacks for engineering software Engineering software for AS • 250 POs (process objects) • 1000 POs SIMATIC PCS 7 PowerPack Engineering Software AS for extending the engineering software for AS 3 languages (German, English, French), executes with Windows 2000 Professional/ 2000 Server or Windows XP Professional/ Server 2003, floating license for 1 user Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions • From 250 POs to 1000 POs 6ES7 658-1AB16-0YD5 • From 1000 POs to 2000 POs 6ES7 658-1AC16-0YD5 • From 2000 POs to 3000 POs 6ES7 658-1AD16-0YD5 6ES7 658-1AA16-0YA5 • From 3000 POs to 5000 POs 6ES7 658-1AE16-0YD5 6ES7 658-1AB16-0YA5 • From 5000 POs to unlimited POs 6ES7 658-1AF16-0YD5 • 2000 POs 6ES7 658-1AC16-0YA5 • 3000 POs 6ES7 658-1AD16-0YA5 • 5000 POs 6ES7 658-1AE16-0YA5 • Unlimited POs 6ES7 658-1AF16-0YA5 Engineering software for OS • 250 POs/RC 8K 6ES7 658-2DA16-0YA5 • 1000 POs/RC 32K 6ES7 658-2DB16-0YA5 • 2000 POs/RC 64K 6ES7 658-2DC16-0YA5 • 3000 POs/RC 100K 6ES7 658-2DD16-0YA5 • 5000 POs/RC 150K 6ES7 658-2DE16-0YA5 • 8500 POs/RC 256K 6ES7 658-2DF16-0YA5 Engineering software for AS/OS • 250 POs/RC 8K 6ES7 658-5AA16-0YA5 • 1000 POs/RC 32K 6ES7 658-5AB16-0YA5 • 2000 POs/RC 64K 6ES7 658-5AC16-0YA5 • 3000 POs/RC 100K 6ES7 658-5AD16-0YA5 • 5000 POs/RC 150K 6ES7 658-5AE16-0YA5 • Unlimited POs/RC 256K 6ES7 658-5AF16-0YA5 SIMATIC PCS 7 PowerPack Engineering Software OS for extending the engineering software for OS 3 languages (German, English, French), executes with Windows 2000 Professional/ 2000 Server or Windows XP Professional/ Server 2003, floating license for 1 user Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions • From 250 POs/RC 8K to 1000 POs/RC 32K 6ES7 658-2DB16-0YD5 • From 1000 POs/RC 32K to 2000 POs/RC 64K 6ES7 658-2DC16-0YD5 • From 2000 POs/RC 64K to 3000 POs/RC 100K 6ES7 658-2DD16-0YD5 • From 3000 POs/RC 100K to 5000 POs/RC 150K 6ES7 658-2DE16-0YD5 • From 5000 POs/RC 150K to 8500 POs/RC 256K 6ES7 658-2DF16-0YD5 SIMATIC PCS 7 PowerPack Engineering Software AS/OS for extending the engineering software for AS/OS 3 languages (German, English, French), executes with Windows 2000 Professional/ 2000 Server or Windows XP Professional/ Server 2003, floating license for 1 user Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions SIMATIC PCS 7 Engineering Software V6.1 Rental License 3 languages (German, English, French), executes with Windows 2000 Professional/ 2000 Server or Windows XP Professional/ Server 2003 Rental license for 50 hours Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions; PCS 7 V6.1 toolset DVD, Microsoft SQL Server including EULA, PC Anywhere Host and supplementary CDs/DVDs (e.g. Microsoft ServicePacks and tools) • For AS, 2000 POs 6ES7 658-1AC16-0YA6 • For OS, 2000 POs/RC 64K 6ES7 658-2DC16-0YA6 14 • From 250 POs/RC 8K to 1000 POs/RC 32K 6ES7 658-5AB16-0YD5 • From 1000 POs/RC 32K to 2000 POs/RC 64K 6ES7 658-5AC16-0YD5 • From 2000 POs/RC 64K to 3000 POs/RC 100K 6ES7 658-5AD16-0YD5 • From 3000 POs/RC 100K to 5000 POs/RC 150K 6ES7 658-5AE16-0YD5 • From 5000 POs/RC 150K to unlimited POs/RC 256K 6ES7 658-5AF16-0YD5 Siemens ST PCS 7 · November 2007 14/5 © Siemens AG 2007 Ordering data for previous version SIMATIC PCS 7 V6.1 ES software V6.1 Engineering F/FH Systems Version Cross Checker ■ Selection and Ordering Data SIMATIC Version Cross Checker V6.1 3 languages (German, English, French), executes with Windows 2000 Professional or Windows XP Professional, floating license for 1 user Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions Order No. 6ES7 658-1CX16-2YB5 Version Trail ■ Selection and Ordering Data SIMATIC Version Trail V6.1 5 languages (German, English, French, Spanish, Italian), executes with Windows 2000 Professional, Windows XP Professional or Windows Server 2003, floating license for 1 user Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions Order No. 6ES7 658-1FX16-2YB5 Import/Export Assistant ■ Selection and Ordering Data SIMATIC PCS 7 Import/Export Assistant V6.1 3 languages (German, English, French), executes with Windows 2000 Professional/ 2000 Server or Windows XP Professional/ Server 2003, floating license for 1 user Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions Order No. 6ES7 658-1DX16-2YB5 14 Order No. SIMATIC Route Control Engineering V6.1 3 languages (German, English, French), executes with Windows 2000 Professional/ 2000 Server or Windows XP Professional/ Server 2003 Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions • Floating license for 1 user 6ES7 658-7DX16-0YB5 Order No. S7 F Systems V6.0 Programming and configuration environment for creating and using safety-related STEP 7 programs for a target system based on S7-400H 2 languages (German, English), executes with Windows XP Professional SP2, Windows Server 2003 SP1/SP2 and Windows 2000 SP4, floating license for 1 user Type of delivery: Certificate of license as well as software and electronic documentation on CD 6ES7 833-1CC01-0YA5 S7 F Systems Upgrade from V5.x to V6.0 2 languages (German, English), executes with Windows XP Professional SP2, Windows Server 2003 SP1/SP2 and Windows 2000 SP4, floating license for 1 user Type of delivery: Certificate of license as well as software and electronic documentation on CD 6ES7 833-1CC01-0YE5 Note: With a S7 F Systems Upgrade from V5.x to V6.0, the type of S7 F Systems license changes from single license to floating license. Safety Matrix ■ Selection and Ordering Data Route Control Engineering ■ Selection and Ordering Data ■ Selection and Ordering Data Order No. SIMATIC Safety Matrix Tool Creation, configuration, compilation, loading and online monitoring of the Safety Matrix in a SIMATIC PCS 7 environment Including SIMATIC Safety Matrix Viewer for SIMATIC PCS 7, for operation and monitoring of the Safety Matrix in a SIMATIC PCS 7 environment with several operator control levels 2 languages (German, English), executes with Windows 2000 Professional, Windows XP Professional or Windows 2003 Server, single license for 1 installation Type of delivery: Certificate of license and authorization diskette for Safety Matrix Tool and Safety Matrix Viewer; software and electronic documentation on CD 6ES7 833-1SM00-0YA5 C) SIMATIC Safety Matrix Editor Creation and checking of the Safety Matrix logic on an external computer without a SIMATIC PCS 7/ STEP 7 environment 2 languages (German, English), executes with Windows 2000 Professional, Windows XP Professional or Windows 2003 Server, single license for 1 installation Type of delivery: Certificate of license and authorization diskette; software and electronic documentation on CD 6ES7 833-1SM40-0YA5 C) C) Subject to export regulations: AL: N, ECCN: EAR99S 14/6 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Ordering data for previous version SIMATIC PCS 7 V6.1 ES software V6.1 SIMATIC PDM ■ Selection and Ordering Data Order No. SIMATIC PDM Single Point SIMATIC PDM Single Point V6.0 for operation and parameterization of one field device; communication via PROFIBUS DP/PA or HART modem, including 1 TAG, cannot be expanded with respect to functions or with TAG option/PowerPack 5 languages (German, English, French, Spanish, Italian), executes with Windows 2000 Professional or Windows XP Professional Floating license for 1 user Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions; 2 CDs with SIMATIC PDM V6.0 and device library as well as supplementary DVD with Microsoft ServicePacks and tools 6ES7 658-3HX06-0YA5 ■ Selection and Ordering Data • Floating license for 1 user 6ES7 658-3CX06-2YB5 Communication via standard HART multiplexer 5 languages (German, English, French, Spanish, Italian), executes with Windows 2000 Professional or Windows XP Professional Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions • Floating license for 1 user SIMATIC PDM Basic TAG options / PowerPacks SIMATIC PDM Basic V6.0 for operation and parameterization of field devices and components, communication via PROFIBUS DP/PA, HART modem/interface, RS 232, Modbus, SIREC bus, SIPART DR, including 4 TAGs 5 languages (German, English, French, Spanish, Italian), executes with Windows 2000 Professional or Windows XP Professional Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions; 2 CDs with SIMATIC PDM V6.0 and device library as well as supplementary DVD with Microsoft ServicePacks and tools SIMATIC PDM TAG option for TAG expansion, additive to SIMATIC PDM Basic V6.0 5 languages (German, English, French, Spanish, Italian), executes with Windows 2000 Professional or Windows XP Professional Floating license for 1 user Type of delivery: License key disk, certificate of license, terms and conditions • Floating license for 1 user 6ES7 658-3AX06-0YA5 • Rental license for 50 hours 6ES7 658-3AX06-0YA6 Functional options for SIMATIC PDM V6.0 Integration in STEP 7 / SIMATIC PCS 7 Only required if integration of SIMATIC PDM into HW-Config is to be used 5 languages (German, English, French, Spanish, Italian), executes with Windows 2000 Professional or Windows XP Professional Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions • Floating license for 1 user Order No. Routing through S7-400 5 languages (German, English, French, Spanish, Italian), executes with Windows 2000 Professional or Windows XP Professional Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions 6ES7 658-3EX06-2YB5 • Up to 128 TAGs 6ES7 658-3XA06-2YB5 • Up to 512 TAGs 6ES7 658-3XB06-2YB5 • Up to 1024 TAGs 6ES7 658-3XC06-2YB5 • Up to 2048 TAGs 6ES7 658-3XD06-2YB5 SIMATIC PDM PowerPack for subsequent TAG expansion of all SIMATIC PDM V6.0 product configurations 5 languages (German, English, French, Spanish, Italian), executes with Windows 2000 Professional or Windows XP Professional Floating license for 1 user Type of delivery: License key disk, certificate of license, terms and conditions • From 128 TAGs to 512 TAGs 6ES7 658-3XB06-2YD5 • From 512 TAGs to 1024 TAGs 6ES7 658-3XC06-2YD5 • From 1024 TAGs to 2048 TAGs 6ES7 658-3XD06-2YD5 • From 2048 TAGs to unlimited TAGs 6ES7 658-3XH06-2YD5 14 6ES7 658-3BX06-2YB5 Siemens ST PCS 7 · November 2007 14/7 © Siemens AG 2007 Ordering data for previous version SIMATIC PCS 7 V6.1 ES software V6.1 ■ Selection and Ordering Data Order No. Predefined SIMATIC PDM V6.0 product configurations for special applications 14 SIMATIC PDM Service V6.0 Complete package for standalone users for servicing, with • SIMATIC PDM Basic V6.0 • Option "128 TAGs" 5 languages (German, English, French, Spanish, Italian), executes with Windows 2000 Professional or Windows XP Professional, floating license for 1 user Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions; 2 CDs with SIMATIC PDM V6.0 and device library as well as supplementary DVD with Microsoft ServicePacks and tools 6ES7 658-3JX06-0YA5 SIMATIC PDM S7 V6.0 Complete package for use in a SIMATIC S7 configuration environment, with • SIMATIC PDM Basic V6.0 • Option "Integration in STEP 7/PCS 7" • Option "128 TAGs" 5 languages (German, English, French, Spanish, Italian), executes with Windows 2000 Professional or Windows XP Professional, floating license for 1 user Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions; 2 CDs with SIMATIC PDM V6.0 and device library as well as supplementary DVD with Microsoft ServicePacks and tools 6ES7 658-3KX06-0YA5 SIMATIC PDM PCS 7 V6.0 Complete package for integration into the engineering toolset of the SIMATIC PCS 7 engineering system Floating license for 1 user, with • SIMATIC PDM Basic • Option "Integration in STEP 7/PCS 7" • Option "Routing through S7-400" • Option "128 TAGs" 5 languages (German, English, French, Spanish, Italian), executes with Windows 2000 Professional or Windows XP Professional Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions; 2 CDs with SIMATIC PDM V6.0 and device library as well as supplementary DVD with Microsoft ServicePacks and tools 6ES7 658-3LX06-0YA5 14/8 Controller optimization ■ Selection and Ordering Data SIMATIC PCS 7 PID Tuner V6.1 Controller optimization; option package for CFC 3 languages (German, English, French), executes with Windows 2000 Professional/ 2000 Server or Windows XP Professional/ Server 2003 Floating license for 1 user Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions Order No. 6ES7 653-0SP16-2YB5 Simulation with S7-PLCSIM ■ Selection and Ordering Data • Floating license for 1 user Siemens ST PCS 7 · November 2007 Order No. S7-PLCSIM V5.3 Functional testing of programs which were created with CFC/SFC, on PC/PG 5 languages (German, English, French, Spanish, Italian), executes with Windows 2000 Professional/ 2000 Server or Windows XP Professional/ Server 2003 Type of delivery: License key disk, certificate of license, terms and conditions 6ES7 841-0CC04-0YA5 © Siemens AG 2007 Ordering data for previous version SIMATIC PCS 7 V6.1 OS software V6.1 OS standard software for single station / server / client ■ Selection and Ordering Data Order No. ■ Selection and Ordering Data OS Software Single Station OS Software Server SIMATIC PCS 7 OS Software Single Station V6.1 3 languages (German, English, French), executes with Windows 2000 Professional or Windows XP Professional, single license for 1 installation Electronic documentation on PCS 7 toolset DVD Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions; PCS 7 V6.1 toolset DVD, Microsoft SQL Server including EULA, PC Anywhere Host and supplementary CDs/DVDs (e.g. Microsoft ServicePacks and tools) SIMATIC PCS 7 OS Software Server V6.1 3 languages (German, English, French), executes with Windows 2000 Server or Windows Server 2003, single license for 1 installation Electronic documentation on PCS 7 toolset DVD Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions; PCS 7 V6.1 toolset DVD, Microsoft SQL Server including EULA, PC Anywhere Host and supplementary CDs/DVDs (e.g. Microsoft ServicePacks and tools) Order No. • 250 POs/RT 8K 1) 6ES7 658-2AA16-0YA0 • 250 POs/RT 8K 6ES7 658-2BA16-0YA0 • 1000 POs/RT 32K 6ES7 658-2AB16-0YA0 • 1000 POs/RT 32K 6ES7 658-2BB16-0YA0 • 2000 POs/RT 64K 6ES7 658-2AC16-0YA0 • 2000 POs/RT 64K 6ES7 658-2BC16-0YA0 • 3000 POs/RT 100K 6ES7 658-2AD16-0YA0 • 3000 POs/RT 100K 6ES7 658-2BD16-0YA0 • 5000 POs/RT 150K 6ES7 658-2AE16-0YA0 • 5000 POs/RT 150K 6ES7 658-2BE16-0YA0 • 8500 POs/RT 256K 6ES7 658-2BF16-0YA0 SIMATIC PCS 7 PowerPack OS Software Single Station V6.1 for extending the OS software for a single station 3 languages (German, English, French), executes with Windows 2000 Professional or Windows XP Professional, single license for 1 installation Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions SIMATIC PCS 7 PowerPack OS Software Server V6.1 for extending the OS Software Server 3 languages (German, English, French), executes with Windows 2000 Server or Windows Server 2003, single license for 1 installation Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions • From 250 POs/RT 8K to 1000 POs/RT 32K 6ES7 658-2AB16-0YD0 6ES7 658-2BB16-0YD0 • From 1000 POs/RT 32K to 2000 POs/RT 64K • From 250 POs/RT 8K to 1000 POs/RT 32K 6ES7 658-2AC16-0YD0 6ES7 658-2BC16-0YD0 • From 2000 POs/RT 64K to 3000 POs/RT 100K • From 1000 POs/RT 32K to 2000 POs/RT 64K 6ES7 658-2AD16-0YD0 • From 2000 POs/RT 64K to 3000 POs/RT 100K 6ES7 658-2BD16-0YD0 • From 3000 POs/RT 100K to 5000 POs/RT 150K 6ES7 658-2AE16-0YD0 • From 3000 POs/RT 100K to 5000 POs/RT 150K 6ES7 658-2BE16-0YD0 • From 5000 POs/RT 150K to 8500 POs/RT 256K 6ES7 658-2BF16-0YD0 OS Software Client SIMATIC PCS 7 OS Software Client V6.1 3 languages (German, English, French), executes with Windows 2000 Professional or Windows XP Professional, floating license for 1 user Electronic documentation on PCS 7 toolset DVD Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions; PCS 7 V6.1 toolset DVD, Microsoft SQL Server including EULA, PC Anywhere Host and supplementary CDs/DVDs (e.g. Microsoft ServicePacks and tools) 1) 6ES7 658-2CX16-0YA5 14 A process object (PO) is a synonym for an operable and observable block with approx. 30 variables. Siemens ST PCS 7 · November 2007 14/9 © Siemens AG 2007 Ordering data for previous version SIMATIC PCS 7 V6.1 OS software V6.1 OS archiving ■ Selection and Ordering Data SIMATIC Safety Matrix Viewer Order No. Expansion of integral high-performance cyclic buffer archive (512 variables) of OS Single Station and OS Server SIMATIC PCS 7 PowerPack OS Archive V6.1 3 languages (German, English, French), executes with Windows 2000 Professional/ 2000 Server or Windows XP Professional/ Server 2003, single license for 1 installation Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions • For expansion from 512 to 1500 variables 6ES7 658-2EA16-2YD0 • For expansion from 1500 to 5000 variables 6ES7 658-2EB16-2YD0 • For expansion from 5000 to 10000 variables 6ES7 658-2EE16-2YD0 SIMATIC PCS 7 Bundle OS Archive V6.1 3 languages (German, English, French), executes with Windows 2000 Professional/ 2000 Server or Windows XP Professional/ Server 2003, single license for 1 installation Type of delivery: 4 license key disks, emergency key disk, certificate of license, terms and conditions • 4 x 5000 variables for 4 stations each (Single Station/Server) 6ES7 652-1EA16-2YB0 SFC Visualization ■ Selection and Ordering Data 14 Order No. SIMATIC PCS 7 SFC Visualization V6.1 for displaying and operating SFC sequence controls on an operator station 3 languages (German, English, French), executes with Windows 2000 Professional or Windows XP Professional, floating license for 1 user Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions 6ES7 652-0XD16-2YB5 SIMATIC PCS 7 Upgrade SFC Visualization V5.x to V6.1 3 languages (German, English, French), executes with Windows 2000 Professional or Windows XP Professional, floating license for 1 user Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions 6ES7 652-0XD16-2YF5 14/10 Siemens ST PCS 7 · November 2007 ■ Selection and Ordering Data SIMATIC Safety Matrix Viewer for SIMATIC PCS 7 Operation and monitoring of the safety matrix in the SIMATIC PCS 7 environment with several operating levels 2 languages (German, English), executes with Windows 2000 Professional, Windows XP Professional or Windows 2003 Server, single license for 1 installation Type of delivery: Certificate of license and authorization diskette; software and electronic documentation on CD Order No. 6ES7 833-1SM60-0YA5 Connectivity Pack and Client Access Licenses ■ Selection and Ordering Data Order No. WinCC/Connectivity Pack Single license for 1 installation 6AV6 371-1DR06-1AX0 WinCC/Client Access License for access of (office) computers (without WinCC installation) to archive and alarm data of an operator station (OS single station/OS server) per OPC HDA, OPC A&E or OLE-DB Single license for 1 installation 6AV6 371-1ES06-0AX0 WinCC/Client Access License per Prozessor for access of client to archive and alarm data of an operator station (OS single station/OS server) per OPC HDA, OPC A&E or OLE-DB License for any number of clients per processor 6AV6 371-1ES06-0CX0 C) Subject to export regulations: AL: N, ECCN: EAR99S C) © Siemens AG 2007 Ordering data for previous version SIMATIC PCS 7 V6.1 OS software V6.1 OS redundancy ■ Selection and Ordering Data OS long-term archiving Order No. Design of redundant OS single stations WinCC/Redundancy V6.0 SP3 for alignment of archives following OS restart; single license for 2 installations Installation required on each of the two redundant OS single stations 6AV6 371-1CF06-0DX0 Design of redundant OS servers SIMATIC PCS 7 Server Redundancy V6.1 3 languages (German, English, French), executes with Windows 2000 Server or Windows Server 2003, single license for 2 installations with OS Software Server und WinCC/Redundancy as well as RS 232 connecting cable, 10 m Type of delivery: 2 license key disks, emergency key disk, certificate of license, terms and conditions; PCS 7 V6.1 toolset DVD, Microsoft SQL Server including EULA, PC Anywhere Host and supplementary CDs/DVDs (e.g. Microsoft ServicePacks and tools) • 250 POs/RT 8K 6ES7 652-3XA16-2YA0 • 2000 POs/RT 64K 6ES7 652-3XC16-2YA0 • 3000 POs/RT 100K 6ES7 652-3XD16-2YA0 • 5000 POs/RT 150K 6ES7 652-3XE16-2YA0 • 8500 POs/RT 256K 6ES7 652-3XF16-2YA0 ■ Selection and Ordering Data Order No. SIMATIC StoragePlus V1.1 Software for long-term archiving of data from the SIMATIC PCS 7 process control system; for up to 4 single stations, servers or pairs of servers 3 languages (German, English, French), executes with Windows 2000 Professional/ 2000 Server or Windows XP Professional/ Server 2003, single license for 1 installation Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions 6ES7 652-0XC11-2YB0 SIMATIC PCS 7 Central Archive Server V6.1 Software for long-term archiving of data from the SIMATIC PCS 7 process control system; for up to 11 servers or pairs of servers 3 languages (German, English, French), executes with Windows Server 2003, single license for 1 installation Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions 6ES7 658-2FX16-0YB0 PowerPacks for PO expansion: see OS Software Server PowerPack V6.1 (2 PowerPacks each required) 14 Siemens ST PCS 7 · November 2007 14/11 © Siemens AG 2007 Ordering data for previous version SIMATIC PCS 7 V6.1 SIMATIC BATCH Software V6.1 PCS 7 Web Server ■ Selection and Ordering Data Order No. ■ Selection and Ordering Data • For 3 clients 6ES7 658-2GA16-2YB0 • For 10 clients 6ES7 658-2GB16-2YB0 • For 25 clients 6ES7 658-2GC16-2YB0 • For 50 clients 6ES7 658-2GD16-2YB0 SIMATIC PCS 7 PowerPack Web Server V6.1 3 languages (German, English, French), executes with Windows Server 2003, single license for 1 installation Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions For expansion of PCS 7 Web server license • From 3 to up to 10 clients 6ES7 658-2GB16-2YD0 • From 10 to up to 25 clients 6ES7 658-2GC16-2YD0 • From 25 to up to 50 clients 6ES7 658-2GD16-2YD0 SIMATIC PCS 7 OS Software Client V6.1 1) 3 languages (German, English, French), executes with Windows 2000 Professional or Windows XP Professional, floating license for 1 user Electronic documentation on PCS 7 toolset DVD Type of delivery: • License key disk, emergency key disk, certificate of license, terms and conditions • PCS 7 V6.1 toolset DVD, Microsoft SQL Server including EULA and supplementary CDs/DVDs (e.g. Microsoft ServicePacks and tools) 6ES7 658-2CX16-0YA5 SIMATIC PCS 7 Web Diagnostics Client V6.1 3 languages (German, English, French), executes with Windows Server 2003, single license for 1 installation Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions 6ES7 658-2JX16-2YB0 SIMATIC PCS 7 Web Diagnostics Server V6.1 3 languages (German, English, French), executes with Windows Server 2003, single license for 1 installation Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions 6ES7 658-2HX16-2YB0 1) ■ Selection and Ordering Data SIMATIC BATCH Server Basic Package V6.1 (PO 150) For single station or client/server configuration, comprising • Batch server for 150 batch POs Order No. 6ES7 657-0SA16-0YB0 1) 14 • Recipe System • Batch Control Center (BatchCC) 3 languages (German, English, French), executes with Windows 2000 Professional/ 2000 Server or Windows XP Professional/ Server 2003, single license for 1 installation Type of delivery: License key disk, certificate of license, terms and conditions 14/12 Order No. OS Software Client SIMATIC PCS 7 Web Server V6.1 3 languages (German, English, French), executes with Windows Server 2003, single license for 1 installation Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions Siemens ST PCS 7 · November 2007 Deviating from the specification in the ordering data, the license of the OS Software Client V6.1 in this special application is also enabled for the Microsoft Windows Server 2003 operating system. ■ Selection and Ordering Data Order No. SIMATIC BATCH PO Options V6.1 For expansion of the SIMATIC BATCH Server Basic Package 3 languages (German, English, French), executes with Windows 2000 Professional/ 2000 Server or Windows XP Professional/ Server 2003, single license for 1 installation Type of delivery: License key disk, certificate of license, terms and conditions • To batch with 300 POs 6ES7 657-0XE16-2YB0 • To batch with 600 POs 6ES7 657-0XB16-2YB0 • To batch with 1800 POs 6ES7 657-0XC16-2YB0 • To batch with unlimited POs 6ES7 657-0XD16-2YB0 © Siemens AG 2007 Ordering data for previous version SIMATIC PCS 7 V6.1 Route Control Software V6.1 ■ Selection and Ordering Data Order No. SIMATIC BATCH PowerPacks V6.1 For expansion of batch POs 3 languages (German, English, French), executes with Windows 2000 Professional/ 2000 Server or Windows XP Professional/ Server 2003, single license for 1 installation Type of delivery: License key disk, certificate of license, terms and conditions • From batch with 300 POs to batch with 600 POs 6ES7 657-0XB16-2YD0 • From batch with 600 POs to batch with 1800 POs 6ES7 657-0XC16-2YD0 • From batch with 1800 POs to batch with unlimited POs 6ES7 657-0XD16-2YD0 SIMATIC BATCH BatchCC V6.1 3 languages (German, English, French), executes with Windows 2000 Professional/ 2000 Server or Windows XP Professional/ Server 2003, floating license for 1 user Type of delivery: License key disk, certificate of license, terms and conditions 6ES7 657-0LX16-2YB5 SIMATIC BATCH Recipe System V6.1 3 languages (German, English, French), executes with Windows 2000 Professional/ 2000 Server or Windows XP Professional/ Server 2003, floating license for 1 user Type of delivery: License key disk, certificate of license, terms and conditions 6ES7 657-0AX16-2YB5 SIMATIC BATCH Batch Planning V6.1 3 languages (German, English, French), executes with Windows 2000 Professional/ 2000 Server or Windows XP Professional/ Server 2003, floating license for 1 user Type of delivery: License key disk, certificate of license, terms and conditions 6ES7 657-0BX16-2YB5 SIMATIC BATCH Hierarchical Recipe V6.1 3 languages (German, English, French), executes with Windows 2000 Professional/ 2000 Server or Windows XP Professional/ Server 2003, single license for 1 installation Type of delivery: License key disk, certificate of license, terms and conditions 6ES7 657-0FX16-2YB0 SIMATIC BATCH ROP Library V6.1 3 languages (German, English, French), executes with Windows 2000 Professional/ 2000 Server or Windows XP Professional/ Server 2003, single license for 1 installation Type of delivery: License key disk, certificate of license, terms and conditions 6ES7 657-0GX16-2YB0 ■ Selection and Ordering Data Order No. SIMATIC BATCH Separation Procedures/ Formulas V6.1 3 languages (German, English, French), executes with Windows 2000 Professional/ 2000 Server or Windows XP Professional/ Server 2003, single license for 1 installation Type of delivery: License key disk, certificate of license, terms and conditions 6ES7 657-0HX16-2YB0 SIMATIC BATCH API V6.1 1 language (English), executes with Windows 2000 Professional/ 2000 Server or Windows XP Professional/ Server 2003, single license for 1 installation Type of delivery: License key disk, certificate of license, terms and conditions 6ES7 657-0MX16-2YB0 1) Whereas process objects (PO) represent operable and observable blocks with approx. 30 variables, batch process objects (batch POs) represent instances of plant units and equipment modules (EPH/EOP). ■ Selection and Ordering Data SIMATIC Route Control Server V6.1 for up to 30 simultaneous material transports For single station and client/server configuration 3 languages (German, English, French), executes with Windows 2000 Server or Windows Server 2003, single license for 1 installation Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions Order No. 6ES7 658-7FA16-0YB0 SIMATIC Route Control Server PowerPack V6.1 for expansion of SIMATIC Route Control Server 3 languages (German, English, French), executes with Windows 2000 Server or Windows Server 2003, single license for 1 installation Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions • From 30 to up to 100 simultaneous material transports 6ES7 658-7FB16-0YD0 • From 100 to up to 300 simultaneous material transports 6ES7 658-7FC16-0YD0 14 Siemens ST PCS 7 · November 2007 14/13 © Siemens AG 2007 Ordering data for previous version SIMATIC PCS 7 V6.1 Asset Management Software V6.1 ■ Selection and Ordering Data SIMATIC Route Control Center V6.1 3 languages (German, English, French), executes with Windows 2000 Professional or Windows XP Professional, floating license for 1 user Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions Order No. 6ES7 658-7EX16-0YB5 SIMATIC Route Control Engineering V6.1 3 languages (German, English, French), executes with Windows 2000 Professional/ 2000 Server or Windows XP Professional/ Server 2003 Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions • Floating license for 1 user 6ES7 658-7DX16-0YB5 14 14/14 Siemens ST PCS 7 · November 2007 ■ Selection and Ordering Data SIMATIC PCS 7 Asset Runtime V6.1 incl. 128 asset TAGs1) and one OPC server license For installation on SIMATIC PCS 7 BOX, single station or client 3 languages (German, English, French), executes with Windows 2000 Professional/ 2000 Server or Windows XP Professional/ Server 2003, single license for 1 installation Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions Order No. 6ES7 658-7GA16-0YB0 SIMATIC PCS 7 PowerPack Asset Runtime V6.1 for expanding the TAGs of SIMATIC PCS 7 Asset Runtime V6.1 3 languages (German, English, French), executes with Windows 2000 Professional/ 2000 Server or Windows XP Professional/ Server 2003, single license for 1 installation Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions • From 128 to 512 asset TAGs, incl. one OPC server license 6ES7 658-7GB16-0YD0 • From 512 to 1024 asset TAGs 6ES7 658-7GC16-0YD0 • From 1024 to 2048 asset TAGs 6ES7 658-7GD16-0YD0 • From 2048 to unlimited asset TAGs 6ES7 658-7GH16-0YD0 © Siemens AG 2007 Ordering data for previous version SIMATIC PCS 7 V6.1 PROFIBUS PA components ■ Selection and Ordering Data Order No. Asset Engineering SIMATIC PCS 7 Asset Engineering V6.1 For installation on SIMATIC PCS 7 BOX, single station or client 3 languages (German, English, French), executes with Windows 2000 Professional/ 2000 Server or Windows XP Professional/ Server 2003, floating license for 1 user Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions 1) 6ES7 658-7GX16-0YB5 With asset TAGs, the number of asset objects monitored in SIMATIC PCS 7 is licensed. An asset object represents individual hardware components within a SIMATIC PCS 7 project, e.g. - measuring devices, positioners, switchgear or remote I/Os monitored per EDD or - basic devices or Ethernet components monitored in the maintenance station via an OPC link. In conjunction with PowerPacks, licenses are available for 128, 512, 1024, 2048 and unlimited asset TAGs. ■ Selection and Ordering Data Order No. DP/PA Coupler For transition from RS 485 to MBP • Ex version 6ES7 157-0AD82-0XA0 • Non-Ex version 6ES7 157-0AC82-0XA0 IM 153-2 High Feature Interface module for DP/PA Link and Y-Link 6ES7 153-2BA81-0XB0 B) Accessories PS 307 Load Power Supply Including connection assembly; 120/230 V AC; 24 V DC • 2 A; 50 mm wide 6ES7 307-1BA00-0AA0 • 5 A; 80 mm wide 6ES7 307-1EA00-0AA0 • 5 A, extended temperature range; 80 mm wide 6ES7 307-1EA80-0AA0 • 10 A, 200 mm wide 6ES7 307-1KA01-0AA0 PS 305 Load Power Supply 24/48/60/110 V DC; 24 V DC • 2 A, extended temperature range; 80 mm wide 6ES7 305-1BA80-0AA0 Standard profile rails (without hot swapping function) • 482 mm wide (19 inches) 6ES7 390-1AE80-0AA0 • 530 mm wide 6ES7 390-1AF30-0AA0 B) Subject to export regulations: AL: N, ECCN: EAR99H 14 Siemens ST PCS 7 · November 2007 14/15 © Siemens AG 2007 Ordering data for previous version SIMATIC PCS 7 V6.1 PROFIBUS PA components ■ Selection and Ordering Data Order No. Components for hot swapping and for redundant design Active bus modules for hot swapping • BM IM 157 For two IM 153-2 High Feature modules, for redundant and non-redundant configuration, for extended temperature range, for hot swapping function, permissible operating temperature -25 ... +60 °C 6ES7 195-7HD80-0XA0 • BM DP/PA For one DP/PA coupler, for extended temperature range, for hot swapping function, permissible operating temperature -25 ... +60 °C 6ES7 195-7HF80-0XA0 Profile rail for hot swapping For max. 5 active bus modules • 482 mm wide (19 inches) 6ES7 195-1GA00-0XA0 • 530 mm wide 6ES7 195-1GF30-0XA0 • 620 mm wide 6ES7 195-1GG30-0XA0 14 14/16 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Ordering data for previous version SIMATIC PCS 7 V6.1 Automation systems Standard automation systems (bundles) ■ Selection and Ordering Data ■ Selection and Ordering Data Order No. Ordering units for SIMATIC PCS 7 standard automation systems with Industrial Ethernet interfacing via CP AS 414-3 automation system comprising: SIMATIC PCS 7 AS Runtime license for 100 POs (applies to SIMATIC PCS 7 V6.1 also as Runtime license PCS 7 Library Blocks) Controller type 414-3 with 3 interfaces (MPI/DP, DP and slot for IF module), 2.8 MB main memory (1.4 MB each for program and data), CP 443-1 communications processor for connection to Industrial Ethernet plant bus as well as Order No. AS 416-2 automation system comprising: SIMATIC PCS 7 AS Runtime license for 100 POs (applies to SIMATIC PCS 7 V6.1 also as Runtime license PCS 7 Library Blocks) Controller type 416-2 with 2 interfaces (MPI/DP and DP), 5.6 MB main memory (2.8 MB each for program and data), CP 443-1 communications processor for connection to Industrial Ethernet plant bus as well as • Aluminum UR1 rack (18 slots): • Aluminum UR1 rack (18 slots): - PS 407 power supply; 20 A for 120/230 V AC/DC, 2 backup batteries, memory card 2 MB RAM 6ES7 654-3QD48-0XX0 - PS 407 power supply; 20 A for 120/230 V AC/DC, 2 backup batteries, memory card 4 MB RAM 6ES7 654-3QE48-0XX0 - PS 405 power supply; 20 A for 24 V DC, 2 backup batteries, memory card 2 MB RAM 6ES7 654-6QD48-0XX0 - PS 405 power supply; 20 A for 24 V DC, 2 backup batteries, memory card 4 MB RAM 6ES7 654-6QE48-0XX0 - Without power supply, without backup batteries, without memory card 6ES7 654-0QX48-0XX0 B) B) 6ES7 654-1QD58-0XX0 - PS 407 power supply; 10 A for 120/230 V AC/DC, 2 backup batteries, memory card 4 MB RAM 6ES7 654-1QE58-0XX0 - PS 405 power supply; 10 A for 24 V DC, 2 backup batteries, memory card 2 MB RAM 6ES7 654-4QD58-0XX0 - PS 405 power supply; 10 A for 24 V DC, 2 backup batteries, memory card 4 MB RAM 6ES7 654-4QE58-0XX0 - Without power supply, without backup batteries, without memory card 6ES7 654-0QX58-0XX0 6ES7 654-3JE48-0XX0 - PS 407 power supply; 20 A for 120/230 V AC/DC, 2 backup batteries, memory card 8 MB RAM 6ES7 654-3JF48-0XX0 - PS 405 power supply; 20 A for 24 V DC, 2 backup batteries, memory card 4 MB RAM 6ES7 654-6JE48-0XX0 - PS 405 power supply; 20 A for 24 V DC, 2 backup batteries, memory card 8 MB RAM 6ES7 654-6JF48-0XX0 - Without power supply, without backup batteries, without memory card 6ES7 654-0JX48-0XX0 B) B) • Aluminum UR2 rack (9 slots): • Aluminum UR2 rack (9 slots): - PS 407 power supply; 10 A for 120/230 V AC/DC, 2 backup batteries, memory card 2 MB RAM - PS 407 power supply; 20 A for 120/230 V AC/DC, 2 backup batteries, memory card 4 MB RAM B) B) - PS 407 power supply; 10 A for 120/230 V AC/DC, 2 backup batteries, memory card 4 MB RAM 6ES7 654-1JE58-0XX0 - PS 407 power supply; 10 A for 120/230 V AC/DC, 2 backup batteries, memory card 8 MB RAM 6ES7 654-1JF58-0XX0 - PS 405 power supply; 10 A for 24 V DC, 2 backup batteries, memory card 4 MB RAM 6ES7 654-4JE58-0XX0 - PS 405 power supply; 10 A for 24 V DC, 2 backup batteries, memory card 8 MB RAM 6ES7 654-4JF58-0XX0 - Without power supply, without backup batteries, without memory card 6ES7 654-0JX58-0XX0 B) B) B) Subject to export regulations: AL: N, ECCN: EAR99H 14 Siemens ST PCS 7 · November 2007 14/17 © Siemens AG 2007 Ordering data for previous version SIMATIC PCS 7 V6.1 Automation systems ■ Selection and Ordering Data ■ Selection and Ordering Data Order No. AS 416-3 automation system comprising: SIMATIC PCS 7 AS Runtime license for 100 POs (applies to SIMATIC PCS 7 V6.1 also as Runtime license PCS 7 Library Blocks) Controller type 416-3 with 3 interfaces (MPI/DP, DP and slot for IF module), 11,2 MB main memory (5,6 MB each for program and data), CP 443-1 communications processor for connection to Industrial Ethernet plant bus as well as Order No. AS 417-4 automation system comprising: SIMATIC PCS 7 AS Runtime license for 100 POs (applies to SIMATIC PCS 7 V6.1 also as Runtime license PCS 7 Library Blocks) Controller type 417-4 with 4 interfaces (MPI/DP, DP and 2 slots for IF modules), 30 MB main memory (15 MB each for program and data), CP 443-1 communications processor for connection to Industrial Ethernet plant bus as well as • Aluminum UR1 rack (18 slots): • Aluminum UR1 rack (18 slots): - PS 407 power supply; 20 A for 120/230 V AC/DC, 2 backup batteries, memory card 8 MB RAM 6ES7 654-3KF48-0XX0 - PS 407 power supply; 20 A for 120/230 V AC/DC, 2 backup batteries, memory card 16 MB RAM 6ES7 654-3KG48-0XX0 - PS 405 power supply; 20 A for 24 V DC, 2 backup batteries, memory card 8 MB RAM 6ES7 654-6KF48-0XX0 - PS 405 power supply; 20 A for 24 V DC, 2 backup batteries, memory card 16 MB RAM 6ES7 654-6KG48-0XX0 - Without power supply, without backup batteries, without memory card 6ES7 654-0KX48-0XX0 B) B) • Aluminum UR2 rack (9 slots): - PS 407 power supply; 20 A for 120/230 V AC/DC, 2 backup batteries, memory card 4 MB RAM 6ES7 654-3LE48-0XX0 - PS 407 power supply; 20 A for 120/230 V AC/DC, 2 backup batteries, memory card 16 MB RAM 6ES7 654-3LG48-0XX0 - PS 405 power supply; 20 A for 24 V DC, 2 backup batteries, memory card 4 MB RAM 6ES7 654-6LE48-0XX0 - PS 405 power supply; 20 A for 24 V DC, 2 backup batteries, memory card 16 MB RAM 6ES7 654-6LG48-0XX0 - Without power supply, without backup batteries, without memory card 6ES7 654-0LX48-0XX0 • Aluminum UR2 rack (9 slots): - PS 407 power supply; 10 A for 120/230 V AC/DC, 2 backup batteries, memory card 8 MB RAM 6ES7 654-1KF58-0XX0 - PS 407 power supply; 10 A for 120/230 V AC/DC, 2 backup batteries, memory card 16 MB RAM 6ES7 654-1KG58-0XX0 - PS 405 power supply; 10 A for 24 V DC, 2 backup batteries, memory card 8 MB RAM 6ES7 654-4KF58-0XX0 - PS 405 power supply; 10 A for 24 V DC, 2 backup batteries, memory card 16 MB RAM 6ES7 654-4KG58-0XX0 - Without power supply, without backup batteries, without memory card 6ES7 654-0KX58-0XX0 B) B) - PS 407 power supply; 10 A for 120/230 V AC/DC, 2 backup batteries, memory card 4 MB RAM 6ES7 654-1LE58-0XX0 - PS 407 power supply; 10 A for 120/230 V AC/DC, 2 backup batteries, memory card 16 MB RAM 6ES7 654-1LG58-0XX0 - PS 405 power supply; 10 A for 24 V DC, 2 backup batteries, memory card 4 MB RAM 6ES7 654-4LE58-0XX0 - PS 405 power supply; 10 A for 24 V DC, 2 backup batteries, memory card 16 MB RAM 6ES7 654-4LG58-0XX0 - Without power supply, without backup batteries, without memory card 6ES7 654-0LX58-0XX0 B) Subject to export regulations: AL: N, ECCN: EAR99H 14 14/18 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Ordering data for previous version SIMATIC PCS 7 V6.1 Automation systems Fault-tolerant/safety-related automation systems (bundles) ■ Selection and Ordering Data Order No. Order No. • Aluminium UR2-H rack (2 x 9 slots), with 4 sync modules for distances up to 10 m and 2 fiber-optic sync cables, 1 m • Aluminum UR1 rack (18 slots), without sync modules - Without power supply, without backup batteries, without memory card ■ Selection and Ordering Data AS 414-4-2H automation system Complete fault-tolerant system with two CPUs 414-4H comprising: SIMATIC PCS 7 AS Runtime license for 100 POs (applies to SIMATIC PCS 7 V6.1 also as Runtime license PCS 7 Library Blocks) Controller type 414-4-2H with 2 x 2 integrated interfaces (MPI/DP master and DP master), 2 x 2.8 MB main memory (1.4 MB each for program and data), two CP 443-1 communications processors for connection to Industrial Ethernet plant bus as well as AS 414-4-1H automation system Prepared system with one CPU 414-4H for physically separated redundant systems, for F systems or for later upgrading to a redundant system comprising: SIMATIC PCS 7 AS Runtime license for 100 POs (applies to SIMATIC PCS 7 V6.1 also as Runtime license PCS 7 Library Blocks) Controller type 414-4-1H with 2 integrated interfaces (MPI/DP master and DP master), 2.8 MB main memory (1.4 MB each for program and data), CP 443-1 communications processor for connection to Industrial Ethernet plant bus as well as 6ES7 654-0MX48-0XX0 • Aluminum UR2 rack (9 slots), without sync modules - Two PS 407 power supplies; 10 A for 120/230 V AC/DC, redundant design possible, 4 backup batteries, 2 memory cards of 2 MB RAM each 6ES7 654-2ND68-0XC0 - Two PS 407 power supplies; 10 A for 120/230 V AC/DC, redundant design possible, 4 backup batteries, 2 memory cards of 4 MB RAM each 6ES7 654-2NE68-0XC0 - Two PS 405 power supplies; 10 A for 24 V DC, 4 backup batteries, 2 memory cards of 2 MB RAM each 6ES7 654-4ND68-0XC0 - PS 407 power supply; 10 A for 120/230 V AC/DC, redundant design possible, 2 backup batteries, memory card 2 MB RAM 6ES7 654-2MD58-0XX0 - PS 407 power supply; 10 A for 120/230 V AC/DC, redundant design possible, 2 backup batteries, memory card 4 MB RAM 6ES7 654-2ME58-0XX0 6ES7 654-4MD58-0XX0 - Two PS 405 power supplies; 10 A for 24 V DC, 4 backup batteries, 2 memory cards of 4 MB RAM each 6ES7 654-4NE68-0XC0 - PS 405 power supply; 10 A for 24 V DC, 2 backup batteries, memory card 2 MB RAM - PS 405 power supply; 10 A for 24 V DC, 2 backup batteries, memory card 4 MB RAM 6ES7 654-4ME58-0XX0 - Without power supply, without backup batteries, without memory card 6ES7 654-0NX68-0XC0 - Without power supply, without backup batteries, without memory card 6ES7 654-0MX58-0XX0 14 Siemens ST PCS 7 · November 2007 14/19 © Siemens AG 2007 Ordering data for previous version SIMATIC PCS 7 V6.1 Automation systems ■ Selection and Ordering Data Order No. AS 417-4-1H automation system Prepared system with one CPU 417-4H for physically separated redundant systems, for F systems or for later upgrading to a redundant system comprising: SIMATIC PCS 7 AS Runtime license for 100 POs (applies to SIMATIC PCS 7 V6.1 also as Runtime license PCS 7 Library Blocks) Controller type 417-4-1H with 2 integrated interfaces (MPI/DP master and DP master), 30 MB main memory (15 MB each for program and data), CP 443-1 communications processor for connection to Industrial Ethernet plant bus as well as Order No. AS 417-4-2H automation system Complete fault-tolerant system with two CPUs 417-4H comprising: SIMATIC PCS 7 AS Runtime license for 100 POs (applies to SIMATIC PCS 7 V6.1 also as Runtime license PCS 7 Library Blocks) Controller type 417-4-2H with 2 x 2 integrated interfaces (MPI/DP master and DP master), 2 x 30 MB main memory (15 MB each for program and data), two CP 443-1 communications processors for connection to Industrial Ethernet plant bus as well as • Aluminum UR1 rack (18 slots), without sync modules - Without power supply, without backup batteries, without memory card ■ Selection and Ordering Data 6ES7 654-0RX48-0XX0 • Aluminum UR2 rack (9 slots), without sync modules • Aluminium UR2-H rack (2 x 9 slots), with 4 sync modules for distances up to 10 m and 2 fiber-optic sync cables, 1 m - Two PS 407 power supplies; 10 A for 120/230 V AC/DC, redundant design possible, 4 backup batteries, 2 memory cards of 4 MB RAM each 6ES7 654-2PE68-0XC0 - PS 407 power supply; 10 A for 120/230 V AC/DC, redundant design possible, 2 backup batteries, memory card 4 MB RAM 6ES7 654-2RE58-0XX0 - Two PS 407 power supplies; 10 A for 120/230 V AC/DC, redundant design possible, 4 backup batteries, 2 memory cards of 8 MB RAM each 6ES7 654-2PF68-0XC0 - PS 407 power supply; 10 A for 120/230 V AC/DC, redundant design possible, 2 backup batteries, memory card 16 MB RAM 6ES7 654-2RG58-0XX0 - Two PS 407 power supplies; 10 A for 120/230 V AC/DC, redundant design possible, 4 backup batteries, 2 memory cards of 16 MB RAM each 6ES7 654-2PG68-0XC0 - PS 405 power supply; 10 A for 24 V DC, 2 backup batteries, memory card 4 MB RAM 6ES7 654-4RE58-0XX0 6ES7 654-4PE68-0XC0 - PS 405 power supply; 10 A for 24 V DC, 2 backup batteries, memory card 16 MB RAM 6ES7 654-4RG58-0XX0 - Two PS 405 power supplies; 10 A for 24 V DC, 4 backup batteries, 2 memory cards of 4 MB RAM each 6ES7 654-4PF68-0XC0 - Without power supply, without backup batteries, without memory card 6ES7 654-0RX58-0XX0 - Two PS 405 power supplies; 10 A for 24 V DC, 4 backup batteries, 2 memory cards of 8 MB RAM each - Two PS 405 power supplies; 10 A for 24 V DC, 4 backup batteries, 2 memory cards of 16 MB RAM each 6ES7 654-4PG68-0XC0 - Without power supply, without backup batteries, without memory card 6ES7 654-0PX68-0XC0 B) Subject to export regulations: AL: N, ECCN: EAR99H S7 F Systems Runtime License 14 ■ Selection and Ordering Data S7 F Systems RT License For processing safety-related application programs, for one AS 414F/FH or AS 417F/ FH system 14/20 Siemens ST PCS 7 · November 2007 Order No. 6ES7 833-1CC00-6YX0 B) © Siemens AG 2007 Update/ upgrade packages 15/2 15/4 15/6 15/7 15/8 15/10 15/11 15/12 15/13 15/13 15/16 Software Update Service Software/licenses for system communication via Industrial Ethernet SIMATIC PDM upgrades Upgrades for engineering system Upgrades for operator system Upgrades for SIMATIC BATCH Upgrades for SIMATIC Route Control Upgrades for Asset Management SIMATIC PCS 7 upgrades V4.02 to V6.1 SIMATIC PCS 7 upgrades V5.x/V6.0 to V6.1 SIMATIC PCS 7 upgrades V4.02 to V5.2 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Update/upgrade packages Software Update Service ■ Overview ■ Design Structure and content of the SUS packages for the SIMATIC PCS 7 Software Update Service Note: Each item of an SUS package (list element) represents one software license. SUS Engineering AS/OS • PCS 7 Engineering AS/OS from 250 POs to unlimited POs • PCS 7 Import/Export Assistant • PCS 7 PID-Tuner • Version Cross Manager • Version Trail • PCS 7 SFC Visualization • PCS 7 BCE Software Update Service for SIMATIC PCS 7 Siemens offers a low-cost Software Update Service (SUS) for the SIMATIC PCS 7 software. If you utilize this service, you participate in the further development of the SIMATIC PCS 7 software you are using, and are always in possession of the latest release versions. You can participate in the Software Update Service for SIMATIC PCS 7 by purchasing SUS packages, and is only possible on the basis of the current software versions at the time of purchase. The SUS packages represent a structural division of the SIMATIC PCS 7 software product range using functional and system-specific aspects. The number and composition of the package components identified as list elements are mainly characterized by license aspects (see "Design" for structure and contents). A list element can represent a single software product or also be a synonym for several products of the same type. When purchasing one SUS package, you automatically receive all upgrades and ServicePacks for the software referred to in this SUS package for one year. Within this period of one year, you are therefore authorized to update one corresponding license from your stock for each list element in this package. The total number of SUS packages of one type which you require is therefore determined by the list element which includes most of the software licenses you use. Delivery is to the address entered in the order. An SUS is automatically extended for a further year unless canceled no later than 3 months prior to expiration. Cancellation must be made in writing, and must be sent to the dispatch center with reference to the contract number. Software Update Service for TIA products In addition to the SUS for the SIMATIC PCS 7 process control system, there is also an SUS for SIMATIC PCS 7 products used in a different context (CFC, SIMATIC PDM) within the scope of Totally Integrated Automation (TIA). In the case of SIMATIC PDM, this is identical to the SUS PDM package for the Software Update Service for SIMATIC PCS 7. 15 The SUS range is rounded-off by the SUS for SIMATIC S7 products used in the context of SIMATIC PCS 7, e.g. SUS S7-PLCSIM. 15/2 Siemens ST PCS 7 · November 2007 SUS PDM • PDM Single Point, 1 TAG • PDM Basic from 4 TAGs to unlimited TAGs PDM Service from 128 TAGs to unlimited TAGs PDM S7 from 128 TAGs to unlimited TAGs PDM PCS 7 from 128 TAGs to unlimited TAGs PDM Integration in STEP 7/PCS 7 PDM Routing S7 400 • PDM Standard HART Multiplexer SUS Runtime OS • PCS 7 OS Software Single Station from 250 POs to 5000 POs OS Software Server from 250 POs to 8500 POs • PCS 7 OS Archive • StoragePlus, PCS 7 Central Archive Server (CAS) • PCS 7 OpenPCS 7 Server/OS Client (multi-functional) • PCS 7 OpenPCS 7 Server (stand-alone) • PCS 7 BCE • PCS 7 SFC Visualization SUS OS Client, SFC Visualization • PCS 7 OS Software Client • PCS 7 SFC Visualization SUS OS Web Server • PCS 7 OS Web Server from 3 clients to 50 clients • PCS 7 OS Web Diagnostics Server • PCS 7 OS Web Diagnostics Client SUS Asset Management • PCS 7 Asset Engineering • PCS 7 Asset Runtime • PCS 7 Asset Runtime Basic Package including 100 TAGs © Siemens AG 2007 Update/upgrade packages Software Update Service SUS SIMATIC BATCH Server • PCS 7 SIMATIC BATCH Server Basic Package from 10 UNITs to unlimited UNITs • PCS 7 SIMATIC BATCH Hierarchical Recipe • PCS 7 SIMATIC BATCH ROP Library • PCS 7 SIMATIC BATCH Separation Procedures/Formulas • PCS 7 SIMATIC BATCH API SUS SIMATIC BATCH Client • PCS 7 SIMATIC BATCH Recipe System • PCS 7 SIMATIC BATCH BatchCC • PCS 7 SIMATIC BATCH Batch Planning SUS SIMATIC Route Control • PCS 7 SIMATIC Route Control Engineering • PCS 7 SIMATIC Route Control Center • PCS 7 SIMATIC Route Control Server: 30 to 300 simultaneous material transports • PCS 7 BCE ■ Selection and Ordering Data Order No. SIMATIC PCS 7 Software Update Service Subscription for 1 year with automatic extension; requirement: current software version • PCS 7 Software Update Service for Engineering AS/OS 6ES7 658-1XX00-0YL8 • PCS 7 Software Update Service for PDM 6ES7 658-3XX00-0YL8 • PCS 7 Software Update Service for Runtime OS 6ES7 658-2XX00-0YL8 • PCS 7 Software Update Service for OS Client, SFC Visualization 6ES7 658-2CX00-0YL8 • PCS 7 Software Update Service for OS Web Server 6ES7 658-2GX00-2YL8 • PCS 7 Software Update Service for Asset Management 6ES7 658-7GX00-0YL8 • PCS 7 Software Update Service for SIMATIC BATCH Server 6ES7 657-0SA00-0YL8 • PCS 7 Software Update Service for SIMATIC BATCH Client 6ES7 657-0XX00-2YL8 • PCS 7 Software Update Service for Route Control 6ES7 658-7DX00-0YL8 Software Update Service for TIA products (SIMATIC PCS 7 products used in a different context as well as SIMATIC S7 products used with SIMATIC PCS 7) Subscription for 1 year with automatic extension; requirement: current software version • CFC Software Update Service 6ES7 658-1EX00-2YL8 • SIMATIC PDM Software Update Service 6ES7 658-3XX00-0YL8 • S7-PLCSIM Software Update Service 6ES7 841-0CA01-0YX2 15 Siemens ST PCS 7 · November 2007 15/3 © Siemens AG 2007 Update/upgrade packages Software/licenses for system communication via Industrial Ethernet ■ Overview ■ Selection and Ordering Data With SIMATIC PCS 7, communications software and licenses of SIMATIC NET are used for the system communication via Industrial Ethernet. Their version cycle is not usually synchronous with that of SIMATIC PCS 7. Whereas SIMATIC PCS 7 V7.0 communicates with SIMATIC NET products V6.4 (Edition 2006), the system components of SIMATIC PCS 7 V6.x only work together with SIMATIC NET products V6.3 (Edition 2005). Therefore the following ordering data again shows a comparison of the two versions. When upgrading from SIMATIC PCS 7 V6.x to V7.0, it must be observed that a separate upgrade from V6.3 (Edition 2005) to V6.4 (Edition 2006) is only required for the S7-REDCONNECT communications software. For the other products, the version upgrade is implemented during the SIMATIC PCS 7 upgrade with the SIMATIC PCS 7 Upgrade Packages V6.x to V7.0. Order No. Communications software/licenses for SIMATIC PCS 7 V7.0 SIMATIC NET S7-1613/2006 (V6.4) for Industrial Ethernet S7 communications software for CP 1613, runtime software, in 2 languages (German, English), executes with Windows 2000 Professional/ 2000 Server/ XP Professional/ Server 2003, single license for 1 installation, software and electronic manual on CD-ROM, license key on diskette 6GK1 716-1CB64-3AA0 SIMATIC NET S7REDCONNECT/2006 (V6.4) Software for fail-safe S7 communication over redundant networks, for CP 1613, runtime software, in 2 languages (German, English), executes with Windows 2000 Professional/ 2000 Server/ XP Professional/ Server 2003, single license for 1 installation, software and electronic manual on CD-ROM, license key on diskette 6GK1 716-0HB64-3AA0 SIMATIC NET S7REDCONNECT/2006 (V6.4) Upgrade Software for expansion of S7-1613 to S7-REDCONNECT, runtime software, in 2 languages (German, English), executes with Windows 2000 Professional/ 2000 Server/ XP Professional/ Server 2003, single license for 1 installation, software and electronic manual on CD-ROM, license key on diskette 6GK1 716-0HB64-3AC0 Upgrade of S7-REDCONNECT communications software V6.3 (edition 2005) to V6.4 (edition 2006) SIMATIC NET S7-REDCONNECT Upgrade from V6.3 to V6.4 Software for upgrading S7-REDCONNECT, runtime software, 2 languages (German, English), executes with Windows 2000 Professional/ 2000 Server/ XP Professional/ Server 2003, single license for 1 installation, software and electronic manual on CD-ROM, license key on diskette 6GK1 716-0HB64-3AE0 BCE license PCS 7 BCE V7.0 Runtime license for plant bus communication via standard network card and Basic Communication Ethernet; already integrated in SIMATIC PCS 7 Industrial Workstations, in 3 languages (German, English, French), executes with Windows XP Professional or Windows Server 2003, floating license for 1 user Type of delivery: License key disk, certificate of license, terms and conditions 15 15/4 Siemens ST PCS 7 · November 2007 6ES7 650-1CD07-2YB5 © Siemens AG 2007 Update/upgrade packages Software/licenses for system communication via Industrial Ethernet ■ Selection and Ordering Data Order No. Communications software/licenses for SIMATIC PCS 7 V6.x SIMATIC NET S7-1613/2005 (V6.3) for Industrial Ethernet S7 communications software for CP 1613, runtime license without software, in 2 languages (German, English), executes with Windows 2000 Professional/ 2000 Server/ XP Professional/ Server 2003, single license for 1 installation, license key on diskette; software and electronic manual available on separate SIMATIC NET CD Edition 2005 6GK1 716-1CB63-3AB0 SIMATIC NET S7-REDCONNECT/ 2005 (V6.3) for CP 1613, runtime license without software, for fail-safe S7 communication over redundant networks, in 2 languages (German, English), executes with Windows 2000 Professional/ 2000 Server/ XP Professional/ Server 2003, single license for 1 installation, license key on diskette; software and electronic manual available on separate SIMATIC NET CD Edition 2005 6GK1 716-0HB63-3AB0 SIMATIC NET S7REDCONNECT/2005 (V6.3) Upgrade Runtime license without software, for expansion of S7-1613 to S7-REDCONNECT, in 2 languages (German, English), executes with Windows 2000 Professional/ 2000 Server/ XP Professional/ Server 2003, single license for 1 installation, license key on diskette; software and electronic manual available on separate SIMATIC NET CD Edition 2005 6GK1 716-0HB63-3AD0 ■ Selection and Ordering Data Order No. BCE license SOFTNET-S7/2005 for Industrial Ethernet Runtime license for plant bus communication via standard network card and Basic Communication Ethernet; already integrated with SIMATIC PCS 7 basic devices ES/OS/BATCH/IT, single license for 1 installation, license key on diskette; software and electronic manual available on separate SIMATIC NET CD Edition 2005 6GK1 704-1CW63-3AB0 SIMATIC NET CD Edition 2005 Runtime software for SIMATIC NET products, Edition 2005 (V6.3), in 2 languages (German, English), executes with Windows 2000 Professional/ 2000 Server/ XP Professional/ Server 2003, software and electronic manual on CD 6GK1 704-0AA07-3AA0 D) D) Subject to export regulations: AL: N, ECCN: 5D992B1 15 Siemens ST PCS 7 · November 2007 15/5 © Siemens AG 2007 Update/upgrade packages SIMATIC PDM upgrades ■ Overview ■ Selection and Ordering Data SIMATIC PDM can be integrated in the engineering system, i.e. in the configuration environment of SIMATIC PCS 7, or operated in stand-alone mode. Since the version cycle of SIMATIC PDM is different from that of SIMATIC PCS 7, the upgrade information is summarized here in a separate paragraph "Upgrades of SIMATIC PDM". 15 15/6 Siemens ST PCS 7 · November 2007 Order No. SIMATIC PDM upgrade/update service SIMATIC PDM Upgrade from V5.x to V6.0 for all product versions and combinations 5 languages (German, English, French, Spanish, Italian), executes with Windows 2000 Professional or Windows XP Professional, floating license for 1 user Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions; 2 CDs with SIMATIC PDM V6.0 and device library as well as supplementary DVD with Microsoft ServicePacks and tools 6ES7 651-5CX06-0YE5 SIMATIC PDM Software Update Service Subscription for 1 year with automatic extension Requirement: current software version 6ES7 658-3XX00-0YL8 © Siemens AG 2007 Update/upgrade packages SIMATIC PCS 7 upgrades V6.x to V7.0 Upgrades for engineering system ■ Overview SIMATIC PCS 7 engineering systems with Engineering Software V6.0 or V6.1 can be upgraded to Version 7.0 using the SIMATIC PCS 7 Engineering Upgrade Package. It may also be necessary to upgrade the S7-REDCONNECT communications software from V6.3 (edition 2005) to V6.4 (edition 2006). S7-REDCONNECT is only required in combination with fault-tolerant automation systems. Engineering Upgrade Package V6.x to V7.0 The licenses included in the Engineering Upgrade Package V6.x to V7.0 apply to the following software components of SIMATIC PCS 7 version 6.0/6.1: • PCS 7 Engineering AS (all PO versions) • PCS 7 Engineering OS (all PO versions) • Version Cross Checker • Version Trail • Import/Export Assistant • PCS 7 PID-Tuner • SIMATIC Logon • WinCC Redundancy • SFC Visualization • BCE License • SIMATIC NET S7-1613 for Industrial Ethernet Upgrade of S7-REDCONNECT communications software If fault-tolerant automation systems are used, the engineering station requires the S7-REDCONNECT communications software in addition to the CP 1613 (A2) communications processor for the bus communication. This is available as: • S7-REDCONNECT • S7-REDCONNECT Upgrade (additive to existing S7-1613 communications software) The SIMATIC NET S7-REDCONNECT V6.3 communications software is used in the engineering software with SIMATIC PCS 7 V6.x, on the other hand the SIMATIC NET S7-REDCONNECT V6.4 with SIMATIC PCS 7 V7.0. When upgrading the engineering station to SIMATIC PCS 7 V7.0, an upgrade of the S7-REDCONNECT communications software to V6.4 is therefore also required. Upgrade of SIMATIC PDM SIMATIC PDM can be integrated in the engineering system, i.e. in the configuration environment of SIMATIC PCS 7, or operated in stand-alone mode. Since the version cycle of SIMATIC PDM is different from that of SIMATIC PCS 7, the upgrade information is summarized in a separate section "Upgrades of SIMATIC PDM" directly before this section. Upgrade of S7-PLCSIM simulation software S7-PLCSIM can be integrated in the engineering system, i.e. in the configuration environment of SIMATIC PCS 7. However, the version cycle of S7-PLCSIM is not always synchronous with the version cycle of SIMATIC PCS 7: • SIMATIC PCS 7 V6.1 corresponds to S7-PLCSIM V5.3 • SIMATIC PCS 7 V7.0 + ServicePack 1 corresponds to the current program version S7-PLCSIM V5.4 Engineering software ■ Selection and Ordering Data Order No. Upgrade of engineering software from V6.0/V6.1 to V7.0 SIMATIC PCS 7 Engineering Upgrade Package V6.x to V7.0 for AS/OS engineering 3 languages (German, English, French), executes with Windows XP Professional, floating license for 1 user Type of delivery: License key disks, emergency key disk, certificate of license, terms and conditions; PCS 7 V7.0 toolset DVDs, Microsoft SQL Server 2005 including EULA and supplementary CDs/DVDs (e.g. Microsoft ServicePacks and tools) 6ES7 651-5AX07-0YE5 Communications software ■ Selection and Ordering Data Order No. Upgrade of S7-REDCONNECT communications software from V6.3 (edition 2005) to V6.4 (edition 2006) SIMATIC NET S7-REDCONNECT Upgrade from V6.3 to V6.4 Software for upgrading S7-REDCONNECT, runtime software, 2 languages (German, English), executes with Windows 2000 Professional/ 2000 Server/ XP Professional/ Server 2003, single license for 1 installation, software and electronic manual on CD-ROM, license key on diskette 6GK1 716-0HB64-3AE0 S7-PLCSIM simulation software ■ Selection and Ordering Data Order No. S7-PLCSIM upgrade from V3.x, V4.x, V5.0, V5.2 or V5.3 to V5.4 5 languages (German, English, French, Italian, Spanish), executes with Windows 2000 Professional or Windows XP Professional, floating license for 1 user Type of delivery: Authorization diskette, certificate of license, terms and conditions; software and electronic documentation on CD 6ES7 841-0CC05-0YE5 S7-PLCSIM Software Update Service Subscription for 1 year with automatic extension; requirement: current software version 6ES7 841-0CA01-0YX2 15 Siemens ST PCS 7 · November 2007 15/7 © Siemens AG 2007 Update/upgrade packages SIMATIC PCS 7 upgrades V6.x to V7.0 Upgrades for operator system ■ Overview Upgrade of OS long-term archiving Upgrades combined in packages permit upgrading of existing operator systems V6.0 or V6.1 to V7.0. Upgrades of OS software The upgrades for all PO versions of the OS software from V6.0/V6.1 to V7.0 are distributed between the following two OS upgrade packages: SIMATIC PCS 7 OS Runtime Upgrade Package V6.0/V6.1 to V7.0 for OS single stations/OS servers (including archive servers), with: • PCS 7 OS Software Single Station (all PO versions) • PCS 7 OS Software Server (all PO versions as well as archives) • SFC Visualization • StoragePlus • WinCC Redundancy • SIMATIC Logon • PCS 7 BCE • SIMATIC NET S7-1613 for Industrial Ethernet SIMATIC PCS 7 OS Client / SFC Visualization Upgrade Package V6.0/V6.1 to V7.0 for OS Clients, with: • PCS 7 OS Software Client • SFC Visualization • SIMATIC Logon Upgrade of S7-REDCONNECT communications software If fault-tolerant automation systems are used, the OS single stations/OS servers require the S7-REDCONNECT communications software in addition to the CP 1613 (A2) communications processor for the bus communication. This is available as: • S7-REDCONNECT • S7-REDCONNECT Upgrade (additive to existing S7-1613 communications software) The SIMATIC NET S7-REDCONNECT V6.3 communications software is used in OS single stations/OS servers with SIMATIC PCS 7 V6.x, on the other hand the SIMATIC NET S7-REDCONNECT V6.4 with SIMATIC PCS 7 V7.0. When upgrading the OS single stations/OS servers to SIMATIC PCS 7 V7.0, an upgrade of the S7-REDCONNECT communications software to V6.4 is therefore required. 15 15/8 Siemens ST PCS 7 · November 2007 SIMATIC Upgrade StoragePlus V1.0/V1.1 to V1.2 Note: The SIMATIC Upgrade StoragePlus V1.0/V1.1 to V1.2 is part of the SIMATIC PCS 7 OS Runtime Upgrade Package V6.0/V6.1 to V7.0 Central Archive Server (CAS) Upgrade V6.0/V6.1 to V7.0 Note: The upgrade of the central archive server (CAS) based on the OS software server and additive OS Archive PowerPacks from V6.0/V6.1 to V7.0 is part of the SIMATIC PCS 7 OS Runtime Upgrade Package V6.0/V6.1 to V7.0 SIMATIC PCS 7 OS Web upgrade Using the SIMATIC PCS 7 OS Web Server Upgrade Package, you can upgrade the SIMATIC PCS 7 Web server, SIMATIC PCS 7 Web diagnostics server and SIMATIC PCS 7 Web diagnostics clients from V6.1 to V7.0. © Siemens AG 2007 Update/upgrade packages SIMATIC PCS 7 upgrades V6.x to V7.0 Upgrades for operator system OS software ■ Selection and Ordering Data OS long-term archiving Order No. Upgrades of OS software from V6.0/V6.1 to V7.0 OS upgrade packages for upgrading all PO versions from V6.0/V6.1 to V7.0 SIMATIC PCS 7 OS Runtime Upgrade Package V6.0/V6.1 to V7.0 for OS single station, OS server and archive server, 5-languages (German, English, French, Italian, Spanish), executes with Windows XP Professional or Windows Server 2003, single license for 1 installation Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions; PCS 7 V7.0 toolset DVDs, Microsoft SQL Server 2005 including EULA and supplementary CDs/DVDs (e.g. Microsoft ServicePacks and tools) SIMATIC PCS 7 OS Client/ SFC Visualization Upgrade Package V6.0/V6.1 to V7.0 5 languages (German, English, French, Italian, Spanish), executes with Windows XP Professional, floating license for 1 user Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions; PCS 7 V7.0 toolset DVDs, Microsoft SQL Server 2005 including EULA and supplementary CDs/DVDs (e.g. Microsoft ServicePacks and tools) 6ES7 652-5AX07-0YE0 ■ Selection and Ordering Data Order No. SIMATIC Upgrade StoragePlus V1.0/V1.1 to V1.2 Note: The SIMATIC Upgrade StoragePlus V1.1 to V1.2 is part of the SIMATIC PCS 7 OS Runtime Upgrade Package V6.0/V6.1 to V7.0 Central Archive Server (CAS) Upgrade V6.0/V6.1 to V7.0 Note: The upgrade of the central archive server (CAS) from V6.0/V6.1 to V7.0 is part of the SIMATIC PCS 7 OS Runtime Upgrade Package V6.0/V6.1 to V7.0 OS Web upgrade package ■ Selection and Ordering Data 6ES7 652-5CX07-0YE5 SIMATIC PCS 7 OS Web Server Upgrade Package V6.1 to V7.0 for SIMATIC PCS 7 Web server, SIMATIC PCS 7 Web diagnostics server, SIMATIC PCS 7 Web diagnostics client, 3 languages (German, English, French), executes with Windows Server 2003, single license for 1 installation Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions Order No. 6ES7 652-5DX07-0YF0 Communications software ■ Selection and Ordering Data Order No. Upgrade of S7-REDCONNECT communications software from V6.3 (edition 2005) to V6.4 (edition 2006) SIMATIC NET S7-REDCONNECT Upgrade from V6.3 to V6.4 Software for upgrading S7-REDCONNECT, runtime software, 2 languages (German, English), executes with Windows 2000 Professional/ 2000 Server/ XP Professional/ Server 2003, single license for 1 installation, software and electronic manual on CD-ROM, license key on diskette 6GK1 716-0HB64-3AE0 15 Siemens ST PCS 7 · November 2007 15/9 © Siemens AG 2007 Update/upgrade packages SIMATIC PCS 7 upgrades V6.x to V7.0 Upgrades for SIMATIC BATCH ■ Overview ■ Selection and Ordering Data SIMATIC BATCH packages for upgrading from V6.0/V6.1 to V7.0 The upgrades for all PO versions of the SIMATIC BATCH software from V6.0/V6.1 to V7.0 are distributed between the following two SIMATIC BATCH upgrade packages: SIMATIC BATCH Client upgrade package The SIMATIC BATCH Client upgrade package contains upgrade licenses for:a • SIMATIC BATCH Recipe System • SIMATIC BATCH Batch Planning • SIMATIC BATCH BatchCC • SIMATIC Logon SIMATIC BATCH Server upgrade package The SIMATIC BATCH Server upgrade package contains upgrade licenses for: • SIMATIC BATCH Server Basic Package (including all PO options and PowerPacks) • SIMATIC BATCH Hierarchical Recipe • SIMATIC BATCH ROP Library • SIMATIC BATCH Separation Procedures/Formulas • SIMATIC BATCH API • SIMATIC Logon 15 15/10 Siemens ST PCS 7 · November 2007 Order No. SIMATIC BATCH Client Upgrade Package V6.0/V6.1 to V7.0 3 languages (German, English, French), executes with Windows XP Professional or Windows Server 2003, floating license for 1 user Type of delivery: License key disk, certificate of license, terms and conditions 6ES7 657-5XX07-0YF5 SIMATIC BATCH Server Upgrade Package V6.0/V6.1 to V7.0 3 languages (German, English, French), executes with Windows XP Professional or Windows Server 2003, single license for 1 installation Type of delivery: License key disk, certificate of license, terms and conditions 6ES7 657-5XX07-0YF0 © Siemens AG 2007 Update/upgrade packages SIMATIC PCS 7 upgrades V6.x to V7.0 Upgrades for SIMATIC Route Control ■ Overview ■ Selection and Ordering Data Order No. SIMATIC Route Control upgrade package SIMATIC Route Control upgrade packages The SIMATIC Route Control upgrade package comprises all components for upgrading the Route Control Engineering, Route Control Server and Route Control Client software from V6.0/V6.1 to V7.0. Also involved are SIMATIC Logon, the BCE license PCS 7 BCE and SIMATIC NET S7-1613 for Industrial Ethernet. SIMATIC Route Control Upgrade Package V6.0/V6.1 to V7.0 for Route Control Engineering, Route Control Server and Route Control Center, suitable for single station and client/server configuration 3 languages (German, English, French), executes with Windows XP Professional or Windows Server 2003, single license for 1 installation Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions Upgrade of S7-REDCONNECT communications software If fault-tolerant automation systems are used together with SIMATIC Route Control, the RC single stations/RC servers require the S7-REDCONNECT communications software in addition to the CP 1613 (A2) communications processor for the bus communication. This is available as: • S7-REDCONNECT • S7-REDCONNECT Upgrade (additive to existing S7-1613 communications software) The SIMATIC NET S7-REDCONNECT V6.3 communications software is used in OS single stations/OS servers with SIMATIC PCS 7 V6.x, on the other hand the SIMATIC NET S7-REDCONNECT V6.4 with SIMATIC PCS 7 V7.0. When upgrading the OS single stations/OS servers to SIMATIC PCS 7 V7.0, an upgrade of the S7-REDCONNECT communications software to V6.4 is therefore required. 6ES7 652-5BX07-0YF0 Software Update Service SIMATIC Route Control See Section "Software Update Service" Communications software ■ Selection and Ordering Data Order No. Upgrade of S7-REDCONNECT communications software from V6.3 (edition 2005) to V6.4 (edition 2006) SIMATIC NET S7-REDCONNECT Upgrade from V6.3 to V6.4 Software for upgrading S7-REDCONNECT, runtime software, 2 languages (German, English), executes with Windows 2000 Professional/ 2000 Server/ XP Professional/ Server 2003, single license for 1 installation, software and electronic manual on CD-ROM, license key on diskette 6GK1 716-0HB64-3AE0 15 Siemens ST PCS 7 · November 2007 15/11 © Siemens AG 2007 Update/upgrade packages SIMATIC PCS 7 upgrades V6.x to V7.0 Upgrades for Asset Management ■ Overview ■ Selection and Ordering Data SIMATIC PCS 7 Asset upgrade SIMATIC PCS 7 Asset upgrade With the SIMATIC PCS 7 Asset upgrade package you can upgrade SIMATIC PCS 7 Asset Engineering as well as all TAG versions of SIMATIC PCS 7 Asset Runtime from V6.1 to V7.0. The SNMP OPC server license is also involved. SIMATIC PCS 7 Asset Upgrade Package V6.1 to V7.0 for Asset Engineering and Asset Runtime, 3 languages (German, English, French), executes with Windows XP Professional or Windows Server 2003, single license for 1 installation Type of delivery: License key disk, certificate of license, terms and conditions 15 15/12 Siemens ST PCS 7 · November 2007 Order No. 6ES7 652-5FX07-0YF0 © Siemens AG 2007 Update/upgrade packages SIMATIC PCS 7 upgrades V4.02 to V6.1 SIMATIC PCS 7 upgrades V5.x/V6.0 to V6.1 ■ Overview ■ Selection and Ordering Data This section provides an overview of the upgrade packages with which existing systems based on SIMATIC PCS 7 V5.x or V6.0 can be upgraded to V6.1. The upgrade packages are grouped as follows: • Engineering system • Operator system • SIMATIC BATCH • SIMATIC Route Control Engineering system ■ Selection and Ordering Data Order No. Upgrade of engineering software from V6.0 to V6.1 PCS 7 AS/OS Engineering Upgrade Package for AS/OS upgrade from V6.0 to V6.1 3 languages (German, English, French), executes with Windows 2000 Professional/ 2000 Server or Windows XP Professional/ Server 2003, floating license for 1 user Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions; PCS 7 V6.1 toolset DVD, Microsoft SQL Server including EULA, PC Anywhere Host and supplementary CDs/DVDs (e.g. Microsoft ServicePacks and tools) 6ES7 651-5AX16-0YE5 Upgrade of SIMATIC Version Cross Checker from V6.0 to V6.1 The Version Cross Checker upgrade is included in the PCS 7 AS/OS Engineering Upgrade Package V6.0 to V6.1 (see above) Order No. Upgrades of engineering software from V5.x to V6.1 Upgrade PCS 7 Starter Package from V5.x to V6.1 3 languages (German, English, French), executes with Windows 2000 Professional/ 2000 Server or Windows XP Professional/ Server 2003, floating license for 1 user Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions; PCS 7 V6.1 toolset DVD, Microsoft SQL Server including EULA, PC Anywhere Host and supplementary CDs/DVDs (e.g. Microsoft ServicePacks and tools) • AS/OS upgrade for 250 POs/ RC 8K 6ES7 658-5AA16-0YE5 Upgrade AS Software Engineering from V5.x to V6.1 3 languages (German, English, French), executes with Windows 2000 Server or Windows Server 2003, single license for 1 installation Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions; PCS 7 V6.1 toolset DVD, Microsoft SQL Server including EULA, PC Anywhere Host and supplementary CDs/DVDs (e.g. Microsoft ServicePacks and tools) • AS upgrade for 3000 POs 6ES7 658-1AD16-0YE5 • AS upgrade for unlimited POs 6ES7 658-1AF16-0YE5 Upgrade OS Software Engineering from V5.x to V6.1 3 languages (German, English, French), executes with Windows 2000 Server or Windows Server 2003, single license for 1 installation Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions; PCS 7 V6.1 toolset DVD, Microsoft SQL Server including EULA, PC Anywhere Host and supplementary CDs/DVDs (e.g. Microsoft ServicePacks and tools) • OS upgrade for 2000 POs/ RC 64K 6ES7 658-2DC16-0YE5 • OS upgrade for 5000 POs/ RC 150K 6ES7 658-2DE16-0YE5 15 Siemens ST PCS 7 · November 2007 15/13 © Siemens AG 2007 Update/upgrade packages SIMATIC PCS 7 upgrades V4.02 to V6.1 SIMATIC PCS 7 upgrades V5.x/V6.0 to V6.1 Operator system ■ Selection and Ordering Data Order No. Upgrades of OS software from V6.0 to V6.1 OS upgrade packages for upgrading all PO versions from V6.0 to V6.1 • SIMATIC PCS 7 Upgrade Package Runtime OS V6.0 to V6.1 for OS single station, OS server and archive server, 3 languages (German, English, French), executes with Windows 2000 Professional / 2000 Server or Windows XP Professional / Server 2003, single license for 1 installation 6ES7 652-5AX16-0YE0 Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions; PCS 7 V6.1 toolset DVD, Microsoft SQL Server including EULA, PC Anywhere Host and supplementary CDs/DVDs (e.g. Microsoft ServicePacks and tools) • SIMATIC PCS 7 Upgrade Package OS Client/ SFC Visualization V6.0 to V6.1 3 languages (German, English, French), executes with Windows 2000 Professional or Windows XP Professional, floating license for 1 user 6ES7 652-5CX16-0YE5 Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions; PCS 7 V6.1 toolset DVD, Microsoft SQL server including EULA, PC Anywhere Host and supplementary CDs/DVDs (e.g. Microsoft ServicePacks and tools) SIMATIC PCS 7 Upgrade OS Software Single Station V5.x to V6.1 3 languages (German, English, French), executes with Windows 2000 Professional or Windows XP Professional, single license for 1 installation Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions; PCS 7 V6.1 toolset DVD, Microsoft SQL Server including EULA, PC Anywhere Host and supplementary CDs/DVDs (e.g. Microsoft ServicePacks and tools) 15 • 5000 POs/RT 150K 15/14 1) Order No. SIMATIC PCS 7 Upgrade OS Software Server V5.x to V6.1 3 languages (German, English, French), executes with Windows 2000 Server or Windows Server 2003, single license for 1 installation Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions; PCS 7 V6.1 toolset DVD, Microsoft SQL Server including EULA, PC Anywhere Host and supplementary CDs/DVDs (e.g. Microsoft ServicePacks and tools) • 2000 POs/RT 64K 1) 6ES7 658-2BC16-0YE0 • 5000 POs/RT 150K 1) 6ES7 658-2BE16-0YE0 SIMATIC PCS 7 Upgrade OS Software Client V5.x to V6.1 3 languages (German, English, French), executes with Windows 2000 Professional or Windows XP Professional, floating license for 1 user Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions; PCS 7 V6.1 toolset DVD, Microsoft SQL Server including EULA, PC Anywhere Host and supplementary CDs/DVDs (e.g. Microsoft ServicePacks and tools) 6ES7 658-2CX16-0YE5 Upgrade of SFC Visualization Upgrades of OS software from V5.x to V6.1 • 2000 POs/RT 64K1) ■ Selection and Ordering Data SIMATIC PCS 7 Upgrade SFC Visualization V5.x to V6.1 3 languages (German, English, French), executes with Windows 2000 Professional or Windows XP Professional, floating license for 1 user Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions 6ES7 652-0XD16-2YF5 Upgrade of SIMATIC StoragePlus SIMATIC Upgrade StoragePlus V1.0 to V1.1 Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions 1) 6ES7 658-2AC16-0YE0 6ES7 658-2AE16-0YE0 Siemens ST PCS 7 · November 2007 6ES7 652-0XC11-2YF0 The OS Software Single Station and OS Software Server upgrades support a high-performance archive system for up to 512 variables. To implement larger archives, this volume can be extended using additive OS Archive V6.1 PowerPacks/bundles (see OS archiving). © Siemens AG 2007 Update/upgrade packages SIMATIC PCS 7 upgrades V4.02 to V6.1 SIMATIC PCS 7 upgrades V5.x/V6.0 to V6.1 SIMATIC BATCH ■ Selection and Ordering Data SIMATIC Route Control upgrade packages Order No. SIMATIC BATCH Upgrade from BATCH flexible V4.02 to SIMATIC BATCH V6.1 3 languages (German, English, French), executes with Windows 2000 Professional/ 2000 Server or Windows XP Professional/ Server 2003, floating license for 1 user Type of delivery: License key disk, certificate of license, terms and conditions 6ES7 657-0XX16-0YF0 SIMATIC BATCH Upgrade Package BATCH Client from V6.0 to V6.1 3 languages (German, English, French), executes with Windows 2000 Professional/ 2000 Server or Windows XP Professional/ Server 2003, floating license for 1 user Type of delivery: License key disk, certificate of license, terms and conditions 6ES7 657-5XX16-0YF5 SIMATIC BATCH Upgrade Package BATCH Server from V6.0 to V6.1 3 languages (German, English, French), executes with Windows 2000 Professional/ 2000 Server or Windows XP Professional/ Server 2003, single license for 1 installation Type of delivery: License key disk, certificate of license, terms and conditions 6ES7 657-5XX16-0YF0 ■ Selection and Ordering Data Order No. SIMATIC Route Control Runtime Upgrade Package V6.0 to V6.1 For single station and client/ server configuration 3 languages (German, English, French), executes with Windows 2000 Server or Windows Server 2003, single license for 1 installation Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions 6ES7 652-5BX16-0YF0 SIMATIC Route Control Center Upgrade V6.0 to V6.1 3 languages (German, English, French), executes with Windows 2000 Professional or Windows XP Professional, floating license for 1 user Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions 6ES7 658-7EX16-0YF5 SIMATIC Route Control Engineering Upgrade V6.0 to V6.1 3 languages (German, English, French), executes with Windows 2000 Professional/ 2000 Server or Windows XP Professional/ Server 2003, floating license for 1 user Type of delivery: License key disk, certificate of license, terms and conditions 6ES7 658-7DX16-0YF5 15 Siemens ST PCS 7 · November 2007 15/15 © Siemens AG 2007 Update/upgrade packages SIMATIC PCS 7 upgrades V4.02 to V6.1 SIMATIC PCS 7 upgrades V4.02 to V5.2 ■ Overview Operator system This section summarizes the upgrade software which is required to upgrade the engineering station and operator stations of the SIMATIC PCS 7 process control system from V4.02 to V5.2. Engineering system ■ Selection and Ordering Data Order No. Engineering software upgrade for AS engineering PCS 7 Engineering Toolset Upgrade V4.02 to V5.2 for max. 3000 process objects, executes with Windows NT 4.0 Workstation Type of delivery: • CD with the components: STEP 7, CFC, SFC, S7-SCL, Technological Hierarchy, Import/Export Assistant, DOCPRO and I&C Library • Software licenses on authorization diskette 6ES7 658-1AB05-0YC4 Engineering software upgrade for OS engineering If the engineering station is used for OS engineering, you require an OS Software Upgrade from V4.02 to V5.02 for the OS engineering software package. 15 15/16 Siemens ST PCS 7 · November 2007 ■ Selection and Ordering Data Order No. OS software upgrade PCS 7 OS Software Upgrade V4.02 to V5.2 for OS Software Single Station, OS Software Server, OS Software Terminal and OS Software Engineering (1 upgrade package required for each), executes with Windows NT 4.0 Workstation Type of delivery: • CD with OS I&C software • BCE license and software licenses on authorization diskette 6ES7 658-2XB05-0YC4 © Siemens AG 2007 Appendix 16/2 Training 16/3 Siemens Contacts Worldwide 16/4 A&D Online Services 16/5 Customer Support 16/7 Siemens Solution Partner Automation and Power Distribution 16/8 Software Licenses 16/9 Subject index 16/11 Order no. index 16/16 Conditions of sale and delivery Export regulations Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Appendix Training ■ Faster and more applicable know-how: Hands-on training from the manufacturer SITRAIN® – the Siemens Training for Automation and Industrial Solutions – provides you with comprehensive support in solving your tasks. Training by the market leader in automation and plant engineering enables you to make independent decisions with confidence. Especially where the optimum and efficient use of products and plants are concerned. You can eliminate deficiencies in existing plants, and exclude expensive faulty planning right from the beginning. ■ SITRAIN highlights Top trainers Our trainers are skilled teachers with direct practical experience. Course developers have close contact with product development, and directly pass on their knowledge to the trainers. Practical experience The practical experience of our trainers enables them to teach theory effectively. But since theory can be pretty drab, we attach great importance to practical exercises which can comprise up to half of of the course time. You can therefore immediately implement your new knowledge in practice. We train you on stateof-the-art methodically/didactically designed training equipment. This training approach will give you all the confidence you need. Wide variety With a total of about 300 local attendance courses, we train the complete range of A&D products as well as interaction of the products in systems. Telecourses, teach-yourself software and seminars with a presenter on the Web supplement our classic range of courses. Tailor-made training We are only a short distance away. You can find us at more than 50 locations in Germany, and in 62 countries worldwide. You wish to have individual training instead of one of our 300 courses? Our solution: We will provide a program tailored exactly to your personal requirements. Training can be carried out in our Training Centers or at your company. First-class know-how directly pays for itself: In shorter startup times, high-quality end products, faster troubleshooting and reduced downtimes. In other words, increased profits and lower costs. Achieve more with SITRAIN • Shorter times for startup, maintenance and servicing • Optimized production operations • Reliable configuration and startup • Minimization of plant downtimes • Flexible plant adaptation to market requirements • Compliance with quality standards in production • Increased employee satisfaction and motivation • Shorter familiarization times following changes in technology and staff ■ Contact Visit our site on the Internet at: www.siemens.com/sitrain or let us advise you personally. You can request our latest training catalog from: SITRAIN Customer Support Germany: Phone:+49 (0)1805 / 23 56 11 (0.14 €/min from the German landline network) Fax: +49 (0)1805 / 23 56 12 16 16/2 Siemens ST PCS 7 · November 2007 The right mixture: Blended learning "Blended learning" means a combination of various training media and sequences. For example, a local attendance course in a Training Center can be optimally supplemented by a teachyourself program as preparation or follow-up. Additional effect: Reduced traveling costs and periods of absence. © Siemens AG 2007 Appendix Siemens Contacts Worldwide At http://www.siemens.com/automation/partner you can find details of Siemens contact partners worldwide responsible for particular technologies. You can obtain in most cases a contact partner for • Technical Support, • Spare parts/repairs, • Service, • Training, • Sales or • Consultation/engineering. You start by selecting a • Country, • Product or • Sector. By further specifying the remaining criteria you will find exactly the right contact partner with his/her respective expertise. 16 Siemens ST PCS 7 · November 2007 16/3 © Siemens AG 2007 Appendix A&D Online Services Information and Ordering in the Internet and on CD-ROM ■ A&D in the WWW A detailed knowledge of the range of products and services available is essential when planning and configuring automation systems. It goes without saying that this information must always be fully up-to-date. The Siemens Automation and Drives Group (A&D) has therefore built up a comprehensive range of information in the World Wide Web, which offers quick and easy access to all data required. Under the address http://www.siemens.com/automation you will find everything you need to know about products, systems and services. ■ Product Selection Using the Offline Mall of Automation and Drives Detailed information together with convenient interactive functions: The Offline Mall CA 01 covers more than 80,000 products and thus provides a full summary of the Siemens Automation and Drives product base. Here you will find everything that you need to solve tasks in the fields of automation, switchgear, installation and drives. All information is linked into a user interface which is easy to work with and intuitive. After selecting the product of your choice you can order at the press of a button, by fax or by online link. Information on the Offline Mall CA 01 can be found in the Internet under http://www.siemens.com/automation/ca01 or on CD-ROM or DVD. ■ Easy Shopping with the A&D Mall The A&D Mall is the virtual department store of Siemens AG in the Internet. Here you have access to a huge range of products presented in electronic catalogs in an informative and attractive way. Data transfer via EDIFACT allows the whole procedure from selection through ordering to tracking of the order to be carried out online via the Internet. Numerous functions are available to support you. For example, powerful search functions make it easy to find the required products, which can be immediately checked for availability. Customer-specific discounts and preparation of quotes can be carried out online as well as order tracking and tracing. Please visit the A&D Mall on the Internet under: http://www.siemens.com/automation/mall 16 16/4 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Appendix Customer Support Our Services for Every Phase of Your Project ■ Configuration and Software Engineering Support in configuring and developing with customer-oriented services from actual configuration to implementation of the automation project.1) ■ Service On Site .I With Service On Site we offer services for startup and maintenance, essential for ensuring system availability. In the face of harsh competition you need optimum conditions to keep ahead all the time: A strong starting position. A sophisticated strategy and team for the necessary support - in every phase. Service & Support from Siemens provides this support with a complete range of different services for automation and drives. In Germany 0180 50 50 4441) (0.14 €/min from the German fixed network) In every phase: from planning and startup to maintenance and upgrading. Our specialists know when and where to act to keep the productivity and cost-effectiveness of your system running in top form. ■ Online Support ■ Repairs and Spare Parts The comprehensive information system available round the clock via Internet ranging from Product Support and Service & Support services to Support Tools in the Shop. In Germany 0180 50 50 4461) (0.14 €/min from the German fixed network) http://www.siemens.com/ automation/service&support ■ Technical Support In the operating phase of a machine or automation system we provide a comprehensive repair and spare parts service ensuring the highest degree of operating safety and reliability. ■ Optimization and Upgrading Competent consulting in technical questions covering a wide range of customer-oriented services for all our products and systems. To enhance productivity and save costs in your project we offer high-quality services in optimization and upgrading.1) Tel.: +49 (0)180 50 50 222 Fax: +49 (0)180 50 50 223 (0.14 €/min from the German fixed network) http://www.siemens.com/ automation/support-request ■ Technical Consulting Support in the planning and designing of your project from detailed actual-state analysis, target definition and consulting on product and system questions right to the creation of the automation solution.1) 16 1) For country-specific telephone numbers go to our Internet site at: http://www.siemens.com/automation/service&support Siemens ST PCS 7 · November 2007 16/5 © Siemens AG 2007 Appendix Customer Support ■ Knowledge Base on CD-ROM For locations without online connections to the Internet there are excerpts of the free part of the information sources available on CD-ROM (Service & Support Knowledge Base). This CD-ROM contains all the latest product information at the time of production (FAQs, Downloads, Tips and Tricks, Updates) as well as general information on Service and Technical Support. The CD-ROM also includes a full-text search and our Knowl- edge Manager for targeted searches for solutions. The CD-ROM will be updated every 4 months. Just the same as our online offer in the Internet, the Service & Support Knowledge Base on CD comes complete in 5 languages (German, English, French, Italian, Spanish). You can order the Service & Support Knowledge Base CD from your Siemens contact. Order no. 6ZB5310-0EP30-0BA2 Orders via the Internet (with Automation Value Card or credit card) at: http://www.siemens.com/automation/service&support in the Shop domain. ■ Automation Value Card By entering the card number and PIN you have full access to the Service & Support services being offered. The charge for the services procured is debited from the credits on your Automation Value Card. All the services offered are marked in currency-neutral credits, so you can use the Automation Value Card worldwide. Automation Value Card order numbers Credits Small card - great support The Automation Value Card is an integral component of the comprehensive service concept with which Siemens Automation and Drives will accompany you in each phase of your automation project. Order no. 200 6ES7 997-0BA00-0XA0 500 6ES7 997-0BB00-0XA0 1000 6ES7 997-0BC00-0XA0 10000 6ES7 997-0BG00-0XA0 Detailed information on the services offered is available on our Internet site at: http://www.siemens.com/automation/service&support Service & Support à la Card: Examples It doesn't matter whether you want just specific services from our Technical Support or want to purchase high-quality Support Tools in our Online Shop, you can always pay with your Automation Value Card. No invoicing, transparent and safe. With your personal card number and associated PIN you can view the state of your account and all transactions at any time. Technical Support Services on card. This is how it's done. ”System Utilities“ Tools that can be used directly for configuration, analysis and testing ”Applications“ Complete topic solutions including ready-tested software ”Functions & Samples“ Adaptable blocks for accelerating your developments Card number and PIN are on the back of the Automation Value Card. When delivered, the PIN is covered by a scratch field, guaranteeing that the full credit is on the card. 16 16/6 Siemens ST PCS 7 · November 2007 ”Priority“ Priority processing for urgent cases ”24 h“ Availability round the clock „Extended“ Technical consulting for complex questions Support Tools in the Support Shop © Siemens AG 2007 Appendix Siemens Solution Partner Automation and Power Distribution ■ Overview Solution Partner The Solution Partner Finder, available to you on the Internet, is a comprehensive database in which all Solution Partners, together with their performance profiles, present themselves. Automation s In addition to the search criteria Technology, Sector and Country, you can also search by Company and ZIP Code. From there it is only a small step to making the first contact. s Call up the Solution Partner Finder as follows: • CA 01 on CD-ROM: On the start page via "Contacts & Partners; Siemens Solution Partner Automation and Power Distribution" • CA 01 online: Go directly to the Solution Partner Finder: www.siemens.com/automation/partnerfinder Solution Partner Power Distribution Products and systems from Siemens Automation and Drives provide the ideal platform for all automation tasks. Siemens Solution Partners offer customized future-proof solutions with products and systems from Siemens Automation and Drives. The basis: qualified product and system knowledge coupled with a high degree of solutions and industry-related expertise. Additional information about the Siemens Solution Partner Program is available in the Internet at: www.siemens.com/automation/solutionpartner In the Siemens Solution Partner Program you are certain to find the optimum partner for your specific requirements. Since more than 570 companies worldwide belong to the program, you can be sure to get expert support at your location. 16 Siemens ST PCS 7 · November 2007 16/7 © Siemens AG 2007 Appendix Software Licenses ■ Overview Software types Software requiring a license is categorized into types. The following software types have been defined: • Engineering software • Runtime software Factory license With the Factory License the user has the right to install and use the software at one permanent establishment only. The permanent establishment is defined by one address only.The number of hardware devices on which the software may be installed results from the order data or the Certificate of License (CoL). Engineering software This includes all software products for creating (engineering) user software, e.g. for configuring, programming, parameterizing, testing, commissioning or servicing. Data generated with engineering software and executable programs can be duplicated for your own use or for use by thirdparties free-of-charge. Certificate of license The Certificate of License (CoL) is the licensee's proof that the use of the software has been licensed by Siemens. A CoL is required for every type of use and must be kept in a safe place. Runtime software This includes all software products required for plant/machine operation, e.g. operating system, basic system, system expansions, drivers, etc. The duplication of the runtime software and executable programs created with the runtime software for your own use or for use by third-parties is subject to a charge. You can find information about license fees according to use in the ordering data (e.g. in the catalog). Examples of categories of use include per CPU, per installation, per channel, per instance, per axis, per control loop, per variable, etc. Information about extended rights of use for parameterization/configuration tools supplied as integral components of the scope of delivery can be found in the readme file supplied with the relevant product(s). License types Siemens Automation & Drives offers various types of software license: • Floating license • Single license • Rental license • Trial license Floating license The software may be installed for internal use on any number of devices by the licensee. Only the concurrent user is licensed. The concurrent user is the person using the program. Use begins when the software is started. A license is required for each concurrent user. Single license Unlike the floating license, a single license permits only one installation of the software. The type of use licensed is specified in the ordering data and in the Certificate of License (CoL). Types of use include for example per device, per axis, per channel, etc. One single license is required for each type of use defined. Rental license A rental license supports the "sporadic use" of engineering software. Once the license key has been installed, the software can be used for a specific number of hours (the operating hours do not have to be consecutive). One license is required for each installation of the software. 16 Trial license A trial license supports "short-term use" of the software in a nonproductive context, e.g. for testing and evaluation purposes. It can be transferred to another license. 16/8 Siemens ST PCS 7 · November 2007 Downgrading The licensee is permitted to use the software or an earlier version/release of the software, provided that the licensee owns such a version/release and its use is technically feasible. Delivery versions Software is constantly being updated. The following delivery versions • PowerPack • Upgrade can be used to access updates. Existing bug fixes are supplied with the ServicePack version. PowerPack PowerPacks can be used to upgrade to more powerful software. The licensee receives a new license agreement and CoL (Certificate of License) with the PowerPack. This CoL, together with the CoL for the original product, proves that the new software is licensed. A separate PowerPack must be purchased for each original license of the software to be replaced. Upgrade An upgrade permits the use of a new version of the software on the condition that a license for a previous version of the product is already held. The licensee receives a new license agreement and CoL with the upgrade. This CoL, together with the CoL for the previous product, proves that the new version is licensed. A separate upgrade must be purchased for each original license of the software to be upgraded. ServicePack ServicePacks are used to debug existing products. ServicePacks may be duplicated for use as prescribed according to the number of existing original licenses. License key Siemens Automation & Drives supplies software products with and without license keys. The license key serves as an electronic license stamp and is also the "switch" for activating the software (floating license, rental license, etc.). The complete installation of software products requiring license keys includes the program to be licensed (the software) and the license key (which represents the license). Detailed explanations concerning license conditions can be found in the “Terms and Conditions of Siemens AG” or under http://www.siemens.com/automation/mall (A&D Mall Online-Help System) A&D/Software licenses/En 03.08.06 © Siemens AG 2007 Appendix Subject index ■ A F O Access Point ........................................ 9/31 Active Field Distributor......................... 9/49 Administration ........................................ 2/3 Advanced Process Control (APC) functions................................................. 4/8 Alarms .................................................. 5/10 Archive Server...................................... 5/23 AS-Interface ......................................... 9/51 Asset Management ................................ 8/2 Automation systems............................. 10/2 F modules ...........................................11/25 Faceplate Designer ................................4/9 FastConnect .........................................9/23 FastConnect/SpliTConnect...................9/50 Fault-tolerant automation systems......10/15 Fiber-optic cables.................................9/26 OpenPCS 7 .......................................... 5/27 Operating system................................... 2/6 Operator system .................................... 5/2 Optical Switch Modules OSM .............. 9/21 OS archiving ........................................ 5/19 OS hardware .......................................... 5/4 OS redundancy.................................... 5/16 OS software.......................................... 5/12 OS variables........................................... 5/3 OS-LAN .................................................. 9/4 B Batch automation ................................... 6/2 Batch Control Center ............................. 6/8 Batch Planning..................................... 6/10 Branch & Merge..................................... 4/6 C Cable duct ......................................... 11/12 Central Archive Server ......................... 5/23 Central I/O............................................ 11/4 Chipcard reader..................................... 2/5 Clock synchronization .......................... 5/11 Closed-loop control modules ............. 11/27 Component view .................................... 4/6 Concurrent Engineering ......................... 4/6 Configurator ......................................... 2/18 ConPerMon ............................................ 4/8 Continuous Function Chart (CFC).......... 4/7 Counter modules................................ 11/29 CP 1613 ............................................... 9/28 CP 443-5 Extended.............................. 9/41 D DOCPRO................................................ 4/9 DP/PA link and DP/PA coupler ............. 9/45 Dummy module.................................. 11/12 E Electrical Switch Modules ESM............ 9/21 Electronic Device Description.............. 4/17 Electronic Signature ............................... 2/3 Engineering F/FH systems ................... 4/22 Engineering system ............................... 4/2 ES software ............................................ 4/4 ET 200iSP........................................... 11/30 ET 200M ............................................... 11/9 ET 200pro........................................... 11/56 ET 200S.............................................. 11/39 Ex modules ........................................ 11/22 Ex partition ......................................... 11/12 Expansion units.................................... 11/5 G Glas fiber-optic cables .........................9/39 Graphics Designer .................................4/9 H HART ..................................................11/23 Hazardous area ....................................11/2 Hierarchical Recipe ..............................6/11 I I&C libraries ............................................4/8 I/O subsystem for ET 200M ................11/13 IF 964-DP..............................................9/41 Import/Export Assistant ........................4/12 Industrial Ethernet ..................................9/3 Industrial Ethernet Switches ...................9/6 Industrial Security .................................9/33 Industrial Wireless LAN ........................9/30 Industrial Workstation .............................2/6 Interface module ................................11/11 ITP cables and connectors ..................9/25 P PID-Tuner ............................................... 4/8 Plant bus ................................................ 9/4 Plastic fiber-optic cables...................... 9/40 Power supply cable for Rack PC ......... 2/15 Process Device Manager..................... 4/13 Process I/O .......................................... 11/2 Process monitors ................................. 2/17 Process object ....................................... 5/3 Process object view ............................... 4/6 PROFIBUS............................................ 9/35 PROFIBUS DP...................................... 9/36 PROFIBUS PA ...................................... 9/43 Programming Instructions Driver Blocks.......................................... 2/2 K R Keyboards ............................................2/15 Recipe system ....................................... 6/9 ROP Library ......................................... 6/12 Route Control ......................................... 7/2 Route Control Center ............................. 7/6 Route Control Server.............................. 7/6 Routing................................................. 4/16 Runtime Basic Packages ..................... 3/13 L Libraries..................................................4/8 Long-term archiving .............................5/21 M Maintenance station ...............................8/4 Media converter ...................................9/21 Messages .............................................5/10 Microbox automation system................10/4 Microsoft SQL Server..............................4/4 Migration...............................................13/2 Modbus ................................................9/52 Motor starters .....................................11/49 MTA.......................................................11/6 Multi project engineering........................4/6 Multi-VGA graphics cards ....................2/16 Multi-VGA operation ...............................2/6 16 Siemens ST PCS 7 · November 2007 16/9 © Siemens AG 2007 Appendix Subject index S T S5 Manual Collection ............................. 2/2 S7 F ConfigurationPack ....................... 4/22 S7 Manual Collection ............................. 2/2 S7-PLCSIM........................................... 4/26 S7-REDCONNECT ............................... 9/29 Safety ES Packages............................. 4/25 Safety Matrix ........................................ 4/23 Safety Matrix Viewer............................. 5/15 Safety-related automation systems .... 10/24 Scalability............................................. 1/11 SCALANCE S ....................................... 9/34 SCALANCE X ......................................... 9/6 Script languages.................................. 5/11 Separation Procedures/Formulas ........ 6/12 Sequential Function Chart (SFC) ........... 4/7 Server Basic Package............................ 6/7 SFC Visualization ................................. 5/14 Short-term archiving............................. 5/20 Signal module ........................................ 5/8 Sign-of-life monitoring .......................... 5/11 SIGUARD ........................................... 11/53 SIMATIC BATCH..................................... 6/2 SIMATIC BATCH API ............................ 6/12 SIMATIC IT ........................................... 12/2 SIMATIC Logon ............................... 2/3, 4/5 SIMATIC Manager ........................... 4/2, 4/5 SIMATIC NET.......................................... 9/2 SIMATIC PCS 7 BOX .............................. 3/2 SIMATIC PCS 7 Industrial Workstation... 2/6 SIMATIC PCS 7 MTA ............................ 11/6 SIMATIC PDM....................................... 4/13 SIMATIC PDM PCS 7............................ 4/15 SIMATIC PDM S7 ................................. 4/15 SIMATIC PDM Service.......................... 4/15 SIMATIC PDM Single Point................... 4/14 SIMATIC Route Control .......................... 7/2 SIMATIC Safety Matrix.......................... 4/23 Simulation............................................. 4/26 SIPLUS ................................................. 11/9 SM 321 ............................................... 11/14 SM 322 ............................................... 11/16 SM 323 ............................................... 11/18 SM 331 ............................................... 11/19 SM 332 ............................................... 11/21 SM 421, SM 422, SM 431, SM 432 ...... 11/4 Starter systems ...................................... 3/2 StoragePlus.......................................... 5/21 Switches................................................. 9/6 System architecture ............................. 1/10 System documentation .......................... 2/2 TELEPERM M Manual Collection............2/2 Terminal bus ...........................................9/4 Terminal modules ......................11/6, 11/41 Totally Integrated Automation ...............1/10 Tower Kit ...............................................2/15 Trends ...................................................5/10 16 16/10 Siemens ST PCS 7 · November 2007 V Version Cross Manager ........................4/10 Version Trail ..........................................4/11 W Web Server ...........................................5/25 WinAC Slot416........................................3/9 Wireless LAN ........................................9/30 Y Y-Link ....................................................9/42 © Siemens AG 2007 Appendix Order no. index ■ 3RK1 301-0.... ........................................ 11/51 3RK1 903-0.... 3RK1 903-1.... 3RK1 903-2.... 3RK1 903-3.... ............................. 11/51, 11/52 ........................................ 11/55 ............................. 11/51, 11/52 ........................................ 11/52 6AV6 371-1CF06-0DX0 6AV6 371-1CF06-2AX0 6AV6 371-1DR06-1AX0 6AV6 371-1ES06-0AX0 6AV6 371-1ES06-0CX0 .......................... 14/11 ................... 5/18, 5/24 .......................... 14/10 ................. 5/28, 14/10 ................. 5/28, 14/10 6ES7 195-1B... ......................................... 9/40 6ES7 195-1G... ................... 9/48, 11/12, 14/16 6ES7 195-1J... ........................................ 11/12 6ES7 195-1K... ....................................... 11/12 6ES7 195-7HA.. ............................. 9/48, 11/12 6ES7 195-7HB.. ...................................... 11/12 6ES7 195-7HC.. ...................................... 11/12 6ES7 195-7HD.. .................. 9/48, 11/12, 14/16 6ES7 195-7HF.. .............................. 9/48, 14/16 6ES7 195-7HG.. ............................ 9/48, 11/26 6ES7 195-7KF.. ....................................... 11/26 6AV8 107-..... ........................................... 2/17 6ES7 197-1LA.. ............................. 9/42, 10/23 6DL2 804-..... ......................................... 11/38 6DL5 900-..... ............................................. 2/3 6ES7 305-1.... ............ 9/42, 9/48, 11/10, 14/16 6ES7 307-1.... ............ 9/42, 9/48, 11/10, 14/16 6DS1 916-... ............................................... 5/8 6ES7 321-1B.... ...................................... 11/14 6ES7 321-1C... ....................................... 11/14 6ES7 321-1E... ........................................ 11/14 6ES7 321-1FF01-.... ................................ 11/14 6ES7 321-1FF10-.... ................................ 11/15 6ES7 321-1FH00-.... ............................... 11/14 6ES7 321-7BH.. ...................................... 11/15 6ES7 321-7RD.. ...................................... 11/22 6ES7 321-7TH.. ...................................... 11/15 6ES7 322-1.... ......................................... 11/16 6ES7 322-5F... ........................................ 11/17 6ES7 322-5G... ....................................... 11/17 6ES7 322-5H... ....................................... 11/17 6ES7 322-5R... ....................................... 11/22 6ES7 322-5S............................................ 11/22 6ES7 322-8B... ....................................... 11/17 6ES7 323-1B... ............................ 11/18, 11/25 6ES7 326-1R... ....................................... 11/25 6ES7 326-2B... ....................................... 11/26 6EP1 ... ..................................................... 3/12 6ES5 ... ....................................................... 2/3 6ES7 131-4.... ........................................ 11/46 6ES7 131-7.... ........................................ 11/35 6ES7 132-4.... ........................................ 11/46 6ES7 132-7.... ........................................ 11/35 6ES7 134-4.... ........................................ 11/48 6ES7 134-7.... ........................................ 11/36 6ES7 135-4.... ........................................ 11/48 6ES7 135-7.... ........................................ 11/36 6ES7 138-4.... ............................. 11/46, 11/48 6ES7 138-7A... ....................................... 11/36 6ES7 138-7B... ....................................... 11/36 6ES7 138-7E... ....................................... 11/32 6ES7 141-4.... 6ES7 142-4.... 6ES7 144-4.... 6ES7 145-4.... 6ES7 148-4.... ........................................ 11/60 ........................................ 11/60 ........................................ 11/62 ........................................ 11/62 ............................. 11/63, 11/64 6ES7 151-1.... ........................................ 11/43 6ES7 152-1.... ........................................ 11/33 6ES7 153-2AR03-0XA0 .......................... 11/13 6ES7 153-2BA02-0XB0 .......................... 11/11 6ES7 153-2BA81-0XB0 .......................... 14/16 6ES7 153-2BA82-0XB0 ............................ 9/48 6ES7 153-2BB00-0XB0 .......................... 11/11 6ES7 154-2.... ........................................ 11/59 6ES7 157-0.... ...................... 9/48, 9/49, 14/16 6ES7 193-4CA.. ..................................... 11/42 6ES7 193-4CB.. ..................................... 11/42 6ES7 193-4CC.. ..................................... 11/41 6ES7 193-4CD.. ..................................... 11/41 6ES7 193-4CE......................................... 11/41 6ES7 193-4CF.. ...................................... 11/42 6ES7 193-4CG.. ..................................... 11/42 6ES7 193-4CK.. ..................................... 11/41 6ES7 193-4CL.. ...................................... 11/42 6ES7 193-7AA.. ...................................... 11/33 6ES7 193-7AB.. ...................................... 11/33 6ES7 193-7CA.. ...................................... 11/36 6ES7 193-7DA.. ..................................... 11/32 6ES7 193-7DB.. ..................................... 11/32 6ES7 194-4A... ....................................... 11/59 6ES7 194-4B... ....................................... 11/64 6ES7 194-4C... ............................ 11/60, 11/62 6ES7 194-4D... ....................................... 11/63 6ES7 194-4G... ....................................... 11/59 6ES7 194-4HA.. .......................... 11/60, 11/62 6ES7 194-4HB.. .......................... 11/59, 11/64 6ES7 331-1.... 6ES7 331-7.... 6ES7 332-5.... 6ES7 332-7.... 6ES7 332-8.... 6ES7 336-1.... ......................................... 11/19 ......... 11/19, 11/20, 11/22,11/24 ................... 11/21, 11/22, 11/24 ......................................... 11/21 ......................................... 11/24 ......................................... 11/26 6ES7 341-1.... ........................................... 9/52 6ES7 350-..... .......................................... 11/29 6ES7 355-..... .......................................... 11/28 6ES7 370-..... .......................................... 11/12 6ES7 390-1AB.. ............................. 9/38, 11/37 6ES7 390-1AE.. ......... 9/38, 9/48, 11/37, 14/16 6ES7 390-1AF.. .......... 9/38, 9/48, 11/37, 14/16 6ES7 390-1AF85-..... ................... 11/33, 11/36 6ES7 390-1AJ30-.... ...................... 9/38, 11/37 6ES7 390-1AJ85-.... .................... 11/33, 11/36 6ES7 390-1BC.. ............................. 9/38, 11/37 6ES7 392-1AJ.. .............................. 9/51, 11/12 6ES7 392-1AJ.. ....................................... 11/12 6ES7 392-1AM.. ..................................... 11/12 6ES7 392-1BJ.. ....................................... 11/12 6ES7 392-1BM.. ..................................... 11/12 6ES7 392-1CJ.. ...................................... 11/12 6ES7 392-1CM.. ..................................... 11/12 6ES7 393-4AA.. ...................................... 11/12 6ES7 400-1JA01-.... ................................. 11/5 6ES7 400-1TA01-.... .................................. 11/5 6ES7 421-1.... 6ES7 421-7.... 6ES7 422-1.... 6ES7 422-7.... 6ES7 431-0.... 6ES7 431-1.... 6ES7 431-7.... 6ES7 432-1.... ...........................................11/4 ...........................................11/4 ...........................................11/4 ...........................................11/4 6ES7 460-..... ............................................11/5 6ES7 461-..... ............................................11/5 6ES7 468-..... ............................................11/5 6ES7 492-..... ............................................11/4 6ES7 648-0.... ..................2/15, 3/7, 3/12, 14/3 6ES7 648-1AA.. ...............................2/15, 14/3 6ES7 648-2AF.. ................................2/15, 14/3 6ES7 648-2BF.. .........................................10/6 6ES7 650-0L... .................................14/2, 14/3 6ES7 650-0NF.. .............2/14, 4/3, 5/6, 6/4, 7/5 6ES7 650-0NG.. ...................2/14, 5/6, 6/4, 7/5 6ES7 650-0NH.. ...................2/14, 5/6, 6/4, 7/5 6ES7 650-1A... .................................11/7, 11/8 6ES7 650-1B... ..........................................11/8 6ES7 650-1C... .................................9/29, 15/4 6ES7 650-2M... .........................................14/4 6ES7 650-2P... ...........................................3/11 6ES7 650-2Q... ...........................................3/7 6ES7 650-3G... .........................................14/4 6ES7 650-3X... .................................3/13, 3/14 6ES7 651-5AX.. ..............................15/7, 15/13 6ES7 651-5CX.. ......................4/18, 4/19, 15/6 6ES7 651-6A... ...........................................4/25 6ES7 651-6B.. ............................................4/25 6ES7 652-0XC.. ..................5/22, 14/11, 15/14 6ES7 652-0XD.. ..................5/14, 14/10, 15/14 6ES7 652-0XX.. ................2/5, 2/16, 5/18, 9/29 6ES7 652-1EA.. .......................................14/10 6ES7 952-1KP.. ........................................10/22 6ES7 652-3A... ..........................................5/17 6ES7 652-3B... ..........................................5/18 6ES7 652-3X... ........................................14/11 6ES7 652-5A... ...............................15/9, 15/14 6ES7 652-5B... .............................15/11, 15/15 6ES7 652-5C... ...............................15/9, 15/14 6ES7 652-5D... ..........................................15/9 6ES7 652-5F... .........................................15/12 6ES7 652-6.... ............................................5/15 6ES7 653-0S... ..........................................14/8 6ES7 653-1X... ............................................2/3 6ES7 653-2B... ..............3/7, 3/12, 10/6, 10/13, ......................................................10/21, 10/32 6ES7 654-0JX.. .......................................14/17 6ES7 654-0KX.. .......................................14/18 6ES7 654-0LX.. .......................................14/18 6ES7 654-0MX.. ......................................14/19 6ES7 654-0NX.. ......................................14/19 6ES7 654-0PX.. .......................................14/20 6ES7 654-0QX.. ......................................14/17 6ES7 654-0RX.. .......................................14/20 6ES7 654-0UC.. ........................................10/6 6ES7 654-0XX.. .......................................11/13 6ES7 654-1J... ........................................14/17 6ES7 654-1K... ........................................14/18 6ES7 654-1L... ........................................14/18 6ES7 654-1Q... .......................................14/17 ........................................... 11/4 ........................................... 11/4 ........................................... 11/4 ........................................... 11/4 16 Siemens ST PCS 7 · November 2007 16/11 © Siemens AG 2007 Appendix Order no. index ■ 6ES7 654-2M... ...................................... 14/19 6ES7 654-2N... ....................................... 14/19 6ES7 654-2P... ........................................ 14/20 6ES7 654-2R... ....................................... 14/20 6ES7 654-3J... ........................................ 14/17 6ES7 654-3K... ....................................... 14/18 6ES7 654-3L... ....................................... 14/18 6ES7 654-3Q... ....................................... 14/17 6ES7 654-4J... ........................................ 14/17 6ES7 654-4K... ....................................... 14/18 6ES7 654-4L... ....................................... 14/18 6ES7 654-4M... ...................................... 14/19 6ES7 654-4N... ....................................... 14/19 6ES7 654-4P... ........................................ 14/20 6ES7 654-4Q... ....................................... 14/17 6ES7 654-4R... ....................................... 14/20 6ES7 654-6J... ........................................ 14/17 6ES7 654-6K... ....................................... 14/18 6ES7 654-6L... ....................................... 14/18 6ES7 654-6Q... ....................................... 14/17 6ES7 654-7.... ...... 10/13, 10/14, 10/22, 10/23, ..................................................... 10/33, 10/34 6ES7 654-8.... ...... 10/11, 10/12, 10/13, 10/20, ..................................................... 10/30, 10/31 6ES7 656-7.... .............................. 10/22, 10/33 6ES7 656-8.... ....... 10/20, 10/21, 10/31, 10/32 6ES7 657-0AX.. ............................... 6/9, 14/13 6ES7 657-0BX.. .............................. 6/10,14/13 6ES7 657-0FX.. .............................. 6/11,14/13 6ES7 657-0GX.. ............................. 6/12,14/13 6ES7 657-0HX.. ............................. 6/12, 14/13 6ES7 657-0LX.. ............................... 6/8, 14/13 6ES7 657-0MX.. ............................ 6/12, 14/13 6ES7 657-0SA.. ...................... 6/7, 14/13, 15/3 6ES7 657-0XB.. ............................... 6/7, 14/13 6ES7 657-0XC.. ............................... 6/7, 14/13 6ES7 657-0XD.. ............................... 6/7, 14/13 6ES7 657-0XE.. ............................... 6/7, 14/13 6ES7 657-0XX.. ............................. 15/3, 15/15 6ES7 657-5XX.. ........................... 15/10, 15/15 16 6ES7 658-0GX07-2YB0 ............................ 5/28 6ES7 658-0HX07-2YB0 ............................ 5/28 6ES7 658-1AA16-0YA5 ............................ 14/5 6ES7 658-1AB05-0YC4 .......................... 15/16 6ES7 658-1AB16-.... ................................ 14/5 6ES7 658-1AC16-.... ................................ 14/5 6ES7 658-1AD16-0YA5 ............................ 14/5 6ES7 658-1AD16-0YD5 ........................... 14/5 6ES7 658-1AD16-0YE5 .......................... 15/13 6ES7 658-1AE16-.... ................................. 14/5 6ES7 658-1AF07-.... ................................... 4/9 6ES7 658-1AF16-.... ................................. 14/5 6ES7 658-1AF16-0YE5 .......................... 15/13 6ES7 658-1CX07-.... ................................ 4/10 6ES7 658-1CX16-.... ................................ 14/6 6ES7 658-1DX07-.... ................................ 4/12 6ES7 658-1DX16-.... ................................ 14/6 6ES7 658-1EX00-.... ................................. 15/3 6ES7 658-1FX07-.... ................................. 4/11 6ES7 658-1FX16-.... ................................. 14/6 6ES7 658-1XX00-.... ................................. 15/3 6ES7 658-2AA07-.... ................................ 5/12 6ES7 658-2AA16-.... ................................ 14/9 6ES7 658-2AB07-0YA0 ............................ 5/12 6ES7 658-2AB07-0YD0 ............ 3/7, 3/12, 5/12 6ES7 658-2AB16-.... ................................ 14/9 6ES7 658-2AC07-0YA0 ............................ 5/12 6ES7 658-2AC07-0YD0 ........... 3/7, 3/12, 5/12 6ES7 658-2AC16-0YA0 ............................ 14/9 6ES7 658-2AC16-0YD0 ........................... 14/9 6ES7 658-2AC16-0YE0 .......................... 15/14 6ES7 658-2AD07-.... ................................ 5/12 6ES7 658-2AD16-.... ................................ 14/9 6ES7 658-2AE07-.... ................................. 5/12 6ES7 658-2AE16-0YA0 ............................ 14/9 6ES7 658-2AE16-0YD0 ............................ 14/9 6ES7 658-2AE16-0YE0 .......................... 15/14 16/12 Siemens ST PCS 7 · November 2007 6ES7 658-2BA07-0YA0 ............................. 5/13 6ES7 658-2BA16-0YA0 ............................. 14/9 6ES7 658-2BB07-.... ................................. 5/13 6ES7 658-2BB16-.... ................................. 14/9 6ES7 658-2BC07-.... ................................. 5/13 6ES7 658-2BC16-0YA0 ............................ 14/9 6ES7 658-2BC16-0YD0 ............................ 14/9 6ES7 658-2BC16-0YE0 .......................... 15/14 6ES7 658-2BD07-.... ................................. 5/13 6ES7 658-2BD16-.... ................................. 14/9 6ES7 658-2BE07-.... ................................. 5/13 6ES7 658-2BE16-0YA0 ............................. 14/9 6ES7 658-2BE16-0YD0 ............................ 14/9 6ES7 658-2BE16-0YE0 ........................... 15/14 6ES7 658-2BF07-.... ................................. 5/13 6ES7 658-2BF16-.... ................................. 14/9 6ES7 658-2CX00-0YL8 ............................. 15/3 6ES7 658-2CX07-0YA5 ............................. 5/13 6ES7 658-2CX07-0YA5 ............................. 5/26 6ES7 658-2CX16-0YA5 ........................... 14/12 6ES7 658-2CX16-0YA5 ............................. 14/9 6ES7 658-2CX16-0YE5 .......................... 15/14 6ES7 658-2DA.. ........................................ 14/5 6ES7 658-2DB.. ........................................ 14/5 6ES7 658-2DC16-0YA5 ............................ 14/5 6ES7 658-2DC16-0YA6 ............................ 14/5 6ES7 658-2DC16-0YD5 ............................ 14/5 6ES7 658-2DC16-0YE5 .......................... 15/13 6ES7 658-2DD.. ........................................ 14/5 6ES7 658-2DE16-0YA5 ............................. 14/5 6ES7 658-2DE16-0YD5 ............................ 14/5 6ES7 658-2DE16-0YE5 .......................... 15/13 6ES7 658-2DF07-.... ................................... 4/9 6ES7 658-2DF16-.... ................................. 14/5 6ES7 658-2EA07-2YB0 ................... 5/20, 5/24 6ES7 658-2EA16-2YD0 .......................... 14/10 6ES7 658-2EB07-2YB0 ................... 5/20, 5/24 6ES7 658-2EB07-2YD0 ................... 5/20, 5/24 6ES7 658-2EB16-2YD0 .......................... 14/10 6ES7 658-2EC07-2YB0 ................... 5/20, 5/24 6ES7 658-2EC07-2YD0 ................... 5/20, 5/24 6ES7 658-2ED07-.... ................................. 5/24 6ES7 658-2EE07-.... ................................. 5/24 6ES7 658-2EE16-.... ............................... 14/10 6ES7 658-2EF07-.... ................................. 5/24 6ES7 658-2FA07-.... ................................. 5/24 6ES7 658-2FX16-.... ............................... 14/11 6ES7 658-2GA07-.... ................................ 5/26 6ES7 658-2GA16-.... .............................. 14/12 6ES7 658-2GB07-.... ................................ 5/26 6ES7 658-2GB16-.... .............................. 14/12 6ES7 658-2GC07-.... ................................ 5/26 6ES7 658-2GC16-.... .............................. 14/12 6ES7 658-2GD07-2YB0 ............................ 5/26 6ES7 658-2GD07-2YD0 ........................... 5/26 6ES7 658-2GD16-.... .............................. 14/12 6ES7 658-2GX00-.... ................................. 15/3 6ES7 658-2HX07-.... ................................. 5/26 6ES7 658-2HX16-.... ............................... 14/12 6ES7 658-2JX07-.... ................................ 14/12 6ES7 658-2XB05-.... ............................... 15/16 6ES7 658-2XX00-.... ................................. 15/3 6ES7 658-3AX06-.... ................................. 14/7 6ES7 658-3AX06-0YA5 ............................. 4/18 6ES7 658-3AX06-0YA6 .................... 4/18, 14/7 6ES7 658-3BX06-2YB5 ................... 4/19, 14/7 6ES7 658-3CX06-2YB5 ................... 4/19, 14/7 6ES7 658-3EX06-2YB5 .................... 4/19, 14/7 6ES7 658-3GX06-0YC8 ................... 4/18, 4/19 6ES7 658-3HX06-0YA5 .................... 4/18, 14/7 6ES7 658-3JX06-0YA5 .................... 4/18, 14/8 6ES7 658-3KX06-0YA5 .................... 4/18, 14/8 6ES7 658-3LX06-0YA5 .... 3/7, 3/12, 4/17, 14/8 6ES7 658-3XA06-2YB5 ................... 4/19, 14/7 6ES7 658-3XB06-2YB5 ................... 4/19, 14/7 6ES7 658-3XB06-2YD5 .......... 4/17, 4/19, 14/7 6ES7 658-3XC06-2YB5 ................... 4/19, 14/7 6ES7 658-3XC06-2YD5 .......... 4/17, 4/19, 14/7 6ES7 658-3XD06-2YB5 ....................4/19, 14/7 6ES7 658-3XD06-2YD5 ...........4/17, 4/19, 14/7 6ES7 658-3XH06-2YD5 ...........4/17, 4/19, 14/7 6ES7 658-3XX00-0YL8 ..4/18, 4/19, 15/3, 15/6 6ES7 658-5AA07-0YA5 ...............................4/9 6ES7 658-5AA16-0YA5 .............................14/5 6ES7 658-5AA16-0YE5 ...........................15/13 6ES7 658-5AB07-0YA5 ...............................4/9 6ES7 658-5AB07-0YD5 ..............3/7, 3/12, 4/9 6ES7 658-5AB16-0YA5 .............................14/5 6ES7 658-5AB16-0YD5 ............................14/5 6ES7 658-5AC07-0YA5 ...............................4/9 6ES7 658-5AC07-0YD5 ..............3/7, 3/12, 4/9 6ES7 658-5AC16-.... .................................14/5 6ES7 658-5AD16-.... .................................14/5 6ES7 658-5AE16-.... .................................14/5 6ES7 658-5AF07-.... ....................................4/9 6ES7 658-5AF16-.... ..................................14/5 6ES7 658-7BX41-.... ...................................2/5 6ES7 658-7DX00-.... .................................15/3 6ES7 658-7DX07-.... ...................................7/9 6ES7 658-7DX16-0YB5 ..................14/6, 14/14 6ES7 658-7DX16-0YF5 ...........................15/15 6ES7 658-7EX07-0YB5 ...............................7/7 6ES7 658-7EX16-0YB5 ...........................14/14 6ES7 658-7EX16-0YF5 ...........................15/15 6ES7 658-7FA07-0YB0 ...............................7/7 6ES7 658-7FA16-0YB0 ...........................14/14 6ES7 658-7FB07-0YD0 ...............................7/7 6ES7 658-7FB16-0YD0 ...........................14/14 6ES7 658-7FC07-0YD0 ...............................7/7 6ES7 658-7FC16-0YD0 ...........................14/14 6ES7 658-7GA07-2YB0 ..............................8/5 6ES7 658-7GA16-0YB0 ..........................14/15 6ES7 658-7GB07-0YB0 ..............................8/5 6ES7 658-7GB07-2YB0 ..............................8/5 6ES7 658-7GB16-0YD0 ..........................14/15 6ES7 658-7GC07-2YB0 ..............................8/5 6ES7 658-7GC16-0YD0 ..........................14/15 6ES7 658-7GD16-0YD0 ..........................14/15 6ES7 658-7GH16-0YD0 ..........................14/15 6ES7 658-7GX00-0YL8 .............................15/3 6ES7 658-7GX07-0YB5 ..............................8/5 6ES7 658-7GX16-0YB5 ..........................14/15 6ES7 833-1CC00-.... ....................10/33, 14/20 6ES7 833-1CC01-.... ........................4/22, 14/6 6ES7 833-1SM00-0YA5 ....................4/24, 14/6 6ES7 833-1SM40-0YA5 ....................4/24, 14/6 6ES7 833-1SM60-0YA5 ...........................14/10 © Siemens AG 2007 Appendix Order no. index ■ 6ES7 841-0CA01-0YX2 .......... 4/26, 15/3, 15/7 6ES7 841-0CC04-0YA5 ............................ 14/8 6ES7 841-0CC05-0YA5 ............................ 4/26 6ES7 841-0CC05-0YE5 ................... 4/26, 15/7 6ES7 870-..... ........................................... 9/52 6ES7 900-0.... ................................. 2/15, 14/3 6ES7 902-1AB00-0AA0 ............................ 9/52 6ES7 902-1AC00-0AA0 ......... 5/18, 5/24, 9/52 6ES7 902-1AD00-0AA0 ........................... 9/52 6ES7 902-2.... .......................................... 9/52 6ES7 902-3.... .......................................... 9/52 6ES7 922-..... ........................................... 11/8 6ES7 952-1KP.. ............................ 10/13, 10/33 6ES7 960-1AA.............................. 10/22, 10/33 6ES7 964-2AA04-0AB0 ............................ 9/41 6ES7 972-0AA01-0XA0 ............................ 9/38 6ES7 972-0AB01-0XA0 ............................ 9/38 6ES7 972-0AC80-0XA0 ...... 9/38, 11/33, 11/37 6ES7 972-0BA50-0XA0 ............................ 9/38 6ES7 972-0BB50-0XA0 ............................ 9/38 6ES7 972-0DA00-0AA0 ........................... 9/38 6ES7 972-0DA60-0XA0 ...... 9/38, 11/33, 11/37 6ES7 998-..... ............................................. 2/3 6GF6 220-..... ........................................... 2/17 6GK1 105-..... ........................................... 9/22 6GK1 161-..... ........................... 5/7, 5/18, 9/29 6GK1 415-..... ........................................... 9/51 6GK1 500-0.... .......................................... 9/38 6GK1 500-3.... .......................................... 9/40 6GK1 503-3.... .......................................... 9/39 6GK1 704-0AA07-3AA0 ........................... 15/5 6GK1 704-1CW63-3AB0 .......................... 15/5 6GK1 716-0HB63-3AB0 ........................... 15/5 6GK1 716-0HB63-3AD0 .......................... 15/5 6GK1 716-0HB64-3AA0 ......... 5/18, 9/29, 15/4 6GK1 716-0HB64-3AC0 ........ 5/18, 9/29, 15/4 6GK1 716-0HB64-3AE0 15/4, 15/7, 15/9, 15/11 6GK1 716-1CB63-.... ............................... 15/5 6GK1 716-1CB64-.... ...... 5/7, 5/18, 9/29, 15/4 6GK1 900-0AB00 ..................................... 9/20 6GK1 900-0AB00 ..................................... 9/34 6GK1 901-0CA00-0AA0 ........................... 9/25 6GK1 901-0CA01-0AA0 ........................... 9/25 6GK1 901-0DA20-0AA0 ........................... 9/27 6GK1 901-0DA20-0AA0 ........................... 9/39 6GK1 901-0FB00-0AA0 ........................... 9/40 6GK1 901-1BB10-.... ................................ 9/24 6GK1 901-1BB20-.... ................................ 9/24 6GK1 901-1BE00-0AA1 ........................... 9/24 6GK1 901-1BE00-0AA2 ........................... 9/24 6GK1 901-1BE00-0AA3 ........................... 9/32 6GK1 901-1FC00-.... ................................ 9/24 6GK1 901-1G... ........................................ 9/24 6GK1 905-0A... ........................................ 9/50 6GK1 905-6AA00 ............................ 9/38, 9/50 6GK1 905-6AB00 ............................ 9/38, 9/50 6GK1 905-6PA10 ..................................... 9/40 6GK1 907-0.... .......................................... 9/32 6GK1 970-1.... .......................................... 9/24 6GK1 971-2.... .......................................... 9/51 6GK5 101-..... ........................................... 9/22 6GK5 2.. ................................................... 9/20 6GK5 3.. ................................................... 9/20 6GK5 4.. ................................................... 9/20 6GK5 6.. ................................................... 9/34 6GK5 7.. ................................................... 9/32 6GK7 343-2.... .......................................... 9/51 6GK7 443-1.... .......................................... 9/29 6GK7 443-5.... .......................................... 9/41 A5E00504378 ...........................................5/18 A5E00504378 .............................................6/4 A5E00504378 ...........................................9/29 6XV1 820-5BH10 ............................. 9/27, 9/39 6XV1 820-5BH30 ...................................... 9/27 6XV1 820-5BH50 ............................. 9/27, 9/39 6XV1 820-5BN10 ............................. 9/27, 9/39 6XV1 820-5BN20 ............................. 9/27, 9/39 6XV1 820-5BN50 ............................. 9/27, 9/39 6XV1 820-5BT10 ............................. 9/27, 9/39 6XV1 820-5BT20 ...................................... 9/27 6XV1 820-5BT30 ...................................... 9/27 6XV1 821-0AH10 ...................................... 9/40 6XV1 821-2AN50 ...................................... 9/40 6XV1 830-0EH10 ........................... 9/38, 11/37 6XV1 830-0EN20 ...................................... 9/38 6XV1 830-0EN50 ...................................... 9/38 6XV1 830-0ET10 ....................................... 9/38 6XV1 830-0ET20 ....................................... 9/38 6XV1 830-0ET50 ....................................... 9/38 6XV1 830-0EU10 ...................................... 9/38 6XV1 830-5EH10 ...................................... 9/50 6XV1 830-5FH10 ...................................... 9/50 6XV1 840-2AH10 ............................. 9/24, 9/32 6XV1 840-2AU10 ...................................... 9/24 6XV1 850-..... ............................................ 9/25 6XV1 870-2E ............................................. 9/24 6XV1 870-2J ............................................. 9/32 6XV1 873-..... ............................................ 9/27 6XV2 175-..... .............................................. 5/8 16 Siemens ST PCS 7 · November 2007 16/13 © Siemens AG 2007 Appendix Notes ■ 16 16/14 Siemens ST PCS 7 · November 2007 © Siemens AG 2007 Appendix Notes ■ 16 Siemens ST PCS 7 · November 2007 16/15 © Siemens AG 2007 Appendix Conditions of sale and delivery Export regulations ■ Terms and Conditions of Sale and Delivery By using this catalog you can acquire hardware and software products described therein from Siemens AG subject to the following terms. Please note! The scope, the quality and the conditions for supplies and services, including software products, by any Siemens entity having a registered office outside of Germany, shall be subject exclusively to the General Terms and Conditions of the respective Siemens entity. The following terms apply exclusively for orders placed with Siemens AG. For customers with a seat or registered office in Germany The “General Terms of Payment” as well as the “General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry” shall apply. For software products, the “General License Conditions for Software Products for Automation and Drives for Customers with a Seat or registered Office in Germany” shall apply. For customers with a seat or registered office outside of Germany The “General Terms of Payment” as well as the “General Conditions for Supplies of Siemens, Automation and Drives for Customers with a Seat or registered Office outside of Germany” shall apply. For software products, the “General License Conditions for Software Products for Automation and Drives for Customers with a Seat or registered Office outside of Germany” shall apply. General The dimensions are in mm. In Germany, according to the German law on units in measuring technology, data in inches only apply to devices for export. Illustrations are not binding. Insofar as there are no remarks on the corresponding pages, - especially with regard to data, dimensions and weights given these are subject to change without prior notice. The prices are in € (Euro) ex works, exclusive packaging. The sales tax (value added tax) is not included in the prices. It shall be debited separately at the respective rate according to the applicable legal regulations. Prices are subject to change without prior notice. We will debit the prices valid at the time of delivery. Surcharges will be added to the prices of products that contain silver, copper, aluminum, lead and/or gold if the respective basic official prices for these metals are exceeded. These surcharges will be determined based on the official price and the metal factor of the respective product. The surcharge will be calculated on the basis of the official price on the day prior to receipt of the order or prior to the release order. The metal factor determines the official price as of which the metal surcharges are charged and the calculation method used. The metal factor, provided it is relevant, is included with the price information of the respective products. 16 16/16 Siemens ST PCS 7 · November 2007 An exact explanation of the metal factor and the text of the Comprehensive Terms and Conditions of Sale and Delivery are available free of charge from your local Siemens business office under the following Order Nos.: • 6ZB5310-0KR30-0BA1 (for customers based in Germany) • 6ZB5310-0KS53-0BA1 (for customers based outside Germany) or download them from the Internet http://www.siemens.com/automation/mall (Germany: A&D Mall Online-Help System) ■ Export regulations The products listed in this catalog / price list may be subject to European / German and/or US export regulations. Therefore, any export requiring a license is subject to approval by the competent authorities. According to current provisions, the following export regulations must be observed with respect to the products featured in this catalog / price list: AL Number of the German Export List Products marked other than “N” require an export license. In the case of software products, the export designations of the relevant data medium must also be generally adhered to. Goods labeled with an “AL“ not equal to “N” are subject to a European or German export authorization when being exported out of the EU. ECCN Export Control Classification Number Products marked other than “N” are subject to a reexport license to specific countries. In the case of software products, the export designations of the relevant data medium must also be generally adhered to. Goods labeled with an “ECCN“ not equal to “N” are subject to a US re-export authorization. Even without a label or with an “AL: N” or “ECCN: N”, authorization may be required due to the final destination and purpose for which the goods are to be used. The deciding factors are the AL or ECCN export authorization indicated on order confirmations, delivery notes and invoices. Errors excepted and subject to change without prior notice. A&D/VuL_ohne MZ/En 05.09.06 © Siemens AG 2007 Catalogs of the Automation and Drives Group (A&D) Further information can be obtained from our branch offices listed in the appendix or at www.siemens.com/automation/partner Automation and Drives Interactive catalog on CD-ROM and on DVD Catalog • The Offline Mall of Automation and Drives CA 01 Automation Systems for Machine Tools SINUMERIK & SIMODRIVE NC 60 SINUMERIK & SINAMICS NC 61 Drive Systems Variable-Speed Drives SINAMICS G110/SINAMICS G120 Inverter Chassis Units SINAMICS G120D Distributed Frequency Inverters D 11.1 SINAMICS G130 Drive Converter Chassis Units, SINAMICS G150 Drive Converter Cabinet Units D 11 SINAMICS GM150/SINAMICS SM150 Medium-Voltage Converters D 12 SINAMICS S120 Drive Converter Systems D 21.1 SINAMICS S150 Drive Converter Cabinet Units D 21.3 Asynchronous Motors Standardline D 86.1 Synchronous Motors with Permanent-Magnet Technology, HT-direct D 86.2 DC Motors DA 12 SIMOREG DC MASTER 6RA70 Digital Chassis Converters DA 21.1 SIMOREG K 6RA22 Analog Chassis Converters DA 21.2 PDF: SIMOREG DC MASTER 6RM70 Digital Converter Cabinet Units DA 22 SIMOVERT PM Modular Converter Systems DA 45 SIEMOSYN Motors DA 48 MICROMASTER 410/420/430/440 Inverters DA 51.2 MICROMASTER 411/COMBIMASTER 411 DA 51.3 SIMOVERT MASTERDRIVES Vector Control DA 65.10 SIMOVERT MASTERDRIVES Motion Control DA 65.11 Synchronous and asynchronous servomotors for SIMOVERT MASTERDRIVES DA 65.3 SIMODRIVE 611 universal and POSMO DA 65.4 IEC Squirrel-Cage Motors D 81.1 IEC Squirrel-Cage Motors · New Generation 1LE1 D 81.1 N PDF: Geared Motors M 15 Automation Systems for Machine Tools SIMODRIVE NC 60 Low-Voltage Three-Phase-Motors Industrial Communication for Automation and Drives Catalog IK PI Low-Voltage Controls and Distribution – SIRIUS, SENTRON, SIVACON LV 1 Controls and Distribution – Technical Information SIRIUS, SENTRON, SIVACON LV 1 T SIDAC Reactors and Filters LV 60 SIVENT Fans LV 65 SIVACON 8PS Busbar Trunking Systems LV 70 Motion Control System SIMOTION PM 10 Process Instrumentation and Analytics Field Instruments for Process Automation Measuring Instruments for Pressure, Differential Pressure, Flow, Level and Temperature, Positioners and Liquid Meters FI 01 PDF: Indicators for panel mounting MP 12 SIREC Recorders and Accessories MP 20 SIPART, Controllers and Software MP 31 SIWAREX Weighing Systems WT 01 Continuous Weighing and Process Protection WT 02 Process Analytical Instruments PA 01 PDF: Process Analytics, Components for the System Integration PA 11 SIMATIC Industrial Automation Systems SIMATIC PCS Process Control System ST 45 Products for Totally Integrated Automation and Micro Automation ST 70 SIMATIC PCS 7 Process Control System ST PCS 7 Add-ons for the SIMATIC PCS 7 Process Control System ST PCS 7.1 Migration solutions with the SIMATIC PCS 7 Process Control System ST PCS 7.2 pc-based Automation ST PC SIMATIC Control Systems ST DA SIMATIC Sensors Sensors for Factory Automation FS 10 Systems Engineering Power supplies SITOP power KT 10.1 System cabling SIMATIC TOP connect KT 10.2 • Main Spindle/Feed Motors • Converter Systems SIMODRIVE 611/POSMO Automation Systems for Machine Tools SINAMICS NC 61 • Main Spindle/Feed Motors • Drive System SINAMICS S120 Drive and Control Components for Hoisting Equipment HE 1 Electrical Installation Technology PDF: ALPHA Small Distribution Boards and Distribution Boards, Terminal Blocks ET A1 PDF: ALPHA 8HP Molded-Plastic Distribution System ET A3 PDF: BETA Low-Voltage Circuit Protection ET B1 PDF: DELTA Switches and Socket Outlets ET D1 GAMMA Building Controls ET G1 Human Machine Interface Systems SIMATIC HMI ST 80 System Solutions Applications and Products for Industry are part of the interactive catalog CA 01 TELEPERM M Process Control System PDF: AS 488/TM automation systems PLT 112 PDF: These catalogs are only available as pdf files. A&D/3U/En 26.11.07 www.siemens.com/simatic-pcs7 p Siemens AG Automation and Drives Industrial Automation Systems Postfach 48 48 90327 NÜRNBERG GERMANY w w w.s iemens .co m / a u to m a t io n The information provided in this catalog contains descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. Availability and technical specifications are subject to change without notice. All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners. Order No. E86060-K4678-A111-B3-7600 Subject to change without prior notice | DISPO 09508 | KG 1107 10. BD 340 En / 815070 | Printed in Germany | © Siemens AG 2007 © Siemens AG 2007
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Page Mode : UseOutlines XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Producer : Acrobat Distiller 6.0.1 (Windows) Keywords : Order No. E86060-K4678-A111-B3-7600 Modify Date : 2008:11:14 12:04:47+01:00 Create Date : 2007:11:13 14:56:41+01:00 Metadata Date : 2008:11:14 12:04:47+01:00 Document ID : uuid:b8f7c9a5-bb1d-492d-a230-a164bfa580a2 Instance ID : uuid:1eef314d-d1c5-42c6-98c7-36b2a592a81a Format : application/pdf Title : SIMATIC PCS 7 Process Control System Description : Catalog ST PCS 7, November 2007 Creator : (C) Siemens AG, 2007; A&D AS SM ID Has XFA : No Page Count : 344 Subject : Catalog ST PCS 7, November 2007 Author : (C) Siemens AG, 2007; A&D AS SM IDEXIF Metadata provided by EXIF.tools