Sigma Designs UZB3-HMY Z-Wave USB Stick User Manual UZB3 03 HMYx

Sigma Designs Inc Z-Wave USB Stick UZB3 03 HMYx

Users Manual

Download: Sigma Designs UZB3-HMY Z-Wave USB Stick User Manual UZB3  03   HMYx
Mirror Download [FCC.gov]Sigma Designs UZB3-HMY Z-Wave USB Stick User Manual UZB3  03   HMYx
Document ID3029094
Application IDLNoV/9uBZhW2dEwENsxnJw==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize106.27kB (1328420 bits)
Date Submitted2016-06-15 00:00:00
Date Available2016-06-16 00:00:00
Creation Date2016-06-15 15:25:40
Producing SoftwareGPL Ghostscript 8.15
Document Lastmod2016-06-15 16:02:40
Document TitleMicrosoft Word - UZB3 User Manual 03 - HMY.docx
Document CreatorPScript5.dll Version 5.2.2
Document Author: GQuat

UZB3 Z-Wave USB Adapter
UZB3
Model: ACC-UZB3-HMY
ACC-UZB3-E
Z-Wave USB Stick
User’s Manual
All information are correct at the time of release. Sigma Designs owns the proprietary rights to the information contained herein this document. It may not be
edited, copied or circulated without prior written agreement by Sigma Designs.
© 2014 Sigma Designs, Inc.
UZB3 Z-Wave USB Adapter
CONTENTS
1.
INTRODUCTION ..........................................................................................................................3
2.
SPECIFICATIONS..........................................................................................................................4
3.
PC CONTROLLER APPLICATION SOFTWER INSTALLATION .............................................................6
4.1
Installation .............................................................................................................................6
4.2
Start the Z-Wave PC Controller application ..............................................................................9
4.3
Remove Z-Wave PC Controller application Software .............................................................. 10
4.4
User Interface ....................................................................................................................... 11
4.
FCC NOTICE TO USERS ............................................................................................................... 24
5.
EU DECLARATION OF CONFORMITY........................................................................................... 25
All information are correct at the time of release. Sigma Designs owns the proprietary rights to the information contained herein this document. It may not be
edited, copied or circulated without prior written agreement by Sigma Designs.
© 2014 Sigma Designs, Inc.
UZB3 Z-Wave USB Adapter
1. INTRODUCTION
UZB, Z-Wave USB Stick and bundled application software (PC Controller) enables you to control a
range of Z-Wave enabled devices through your PC or Notebook.
Z-wave is an established short range interoperable two-way RF mesh network technology.
Refer to http://www.z-wave.com/home for detail of the technology.
Refer to http://products.z-wavealliance.org/ for various Z-Wave certified ready products.
Refer to http://www.z-wavealliance.org for Z-Wave Alliances.
Features
Simply plug in UZB to USB port of a PC/Notebook with PC Controller installed
Fully compatible with Z-wave enable network that can communicate with any Z-wave
certified device.
System Requirements
Windows 7/8 32 & 64 bit
Linux kernel 2.6.24+
All information are correct at the time of release. Sigma Designs owns the proprietary rights to the information contained herein this document. It may not be
edited, copied or circulated without prior written agreement by Sigma Designs.
© 2014 Sigma Designs, Inc.
UZB3 Z-Wave USB Adapter
2. SPECIFICATIONS
Z-Wave & RF Specification
Z-Wave wireless transceiver comprises a 3-channel 1GHz ISM FSK/GFSK narrowband radios.
Table 1. UZB3 General Specifications
Region
US
EU
Product
UZB3
Product Description
Model
Part Number
JAPAN
Z-Wave USB Adapter
UZB3-HMY
UZB3-E
UZB-H
ACC-UZB3-HMY
ACC-UZB3-E
ACC-UZB3-H
Manufacturer
Sigma Designs
Z-Wave Chip
SD3503
Z-Wave Library
Serial API Version 4.x
Basic Device Class
Static Controller
Z-Wave Protocol
Z-Wave version ZDK 4.5x and ZDK6.0x
Firmware Version
SDK6.51.06
Communication
Half Duplex
Data Rate
9.6 kbps / 40 kbps / 100 kbps
Number of Channels
Frequency
Range
100 kbps
919.80 MHz
868.42 MHz
922.50 MHz
921.40 MHz
868.40 MHz
923.90 MHz
921.42 MHz
869.85 MHz
926.30 MHz
40 meters Line Of Sight
All information are correct at the time of release. Sigma Designs owns the proprietary rights to the information contained herein this document. It may not be
edited, copied or circulated without prior written agreement by Sigma Designs.
© 2014 Sigma Designs, Inc.
UZB3 Z-Wave USB Adapter
Table 2. Z-Wave RF properties (US) : ACC-UZB3-HMY
Data rate
9.6kbps
40kbps
100kbps
Frequency
921.42 MHz
921.40 MHz
919.80 MHz
Modulation
Frequency Shift
Keying (FSK)
Frequency Shift
Keying (FSK)
Gaussian Frequency
Shift Keying (GFSK)
fC±20kHz
fC±20kHz
fC±29.3kHz
Transmitter Bandwidth
90kHz +/-10%
90kHz +/-10%
110kHz +/-10%
Receiver Bandwidth
250kHz +/-10%
250kHz +/-10%
500kHz +/-10%
Manchester
encoded
Non-return to Zero
(NRZ)
Non-return to Zero
(NRZ)
Low-side
Low-side
Low-side
Frequency deviation
Coding
LO Injection
Table 3. Z-Wave RF properties (Europe) : ACC-UZB3-E
Data rate
9.6kbps
40kbps
100kbps
Frequency
868.42 MHz
868.40 MHz
869.85 MHz
Modulation
Frequency Shift
Keying (FSK)
Frequency Shift
Keying (FSK)
Gaussian Frequency
Shift Keying (GFSK)
fC±20kHz
fC±20kHz
fC±29.3kHz
Transmitter Bandwidth
90kHz +/-10%
90kHz +/-10%
110kHz +/-10%
Receiver Bandwidth
250kHz +/-10%
250kHz +/-10%
500kHz +/-10%
Manchester
encoded
Non-return to Zero
(NRZ)
Non-return to Zero
(NRZ)
Low-side
Low-side
High-side
Frequency deviation
Coding
LO Injection
All information are correct at the time of release. Sigma Designs owns the proprietary rights to the information contained herein this document. It may not be
edited, copied or circulated without prior written agreement by Sigma Designs.
© 2014 Sigma Designs, Inc.
UZB3 Z-Wave USB Adapter
3. PC CONTROLLER APPLICATION SOFTWER INSTALLATION
4.1 Installation
1. Exit all programs.
2. Run the installation file of the Z-Wave PC Controller application.
Figure 1. Welcome page of Z-Wave PC Controller installation
3. Select the installation folder and who should be able to use the Z-Wave PC Controller
application. Please note, that it is not recommended to move the Z-Wave PC Controller
application manually after it has been installed into the above specified folder.
When done, click Next.
All information are correct at the time of release. Sigma Designs owns the proprietary rights to the information contained herein this document. It may not be
edited, copied or circulated without prior written agreement by Sigma Designs.
© 2014 Sigma Designs, Inc.
UZB3 Z-Wave USB Adapter
Figure 2. Installation folder
4. Installation confirmation appears. Click Next again to confirm and start the installation.
Figure 3. Confirmation page of Z-Wave PC Controller installation
All information are correct at the time of release. Sigma Designs owns the proprietary rights to the information contained herein this document. It may not be
edited, copied or circulated without prior written agreement by Sigma Designs.
© 2014 Sigma Designs, Inc.
UZB3 Z-Wave USB Adapter
5. The actual installation procedure will pass with progress indicator and final confirmation
appears.
6. Click Close to complete the installation.
Figure 4. Installation complete
All information are correct at the time of release. Sigma Designs owns the proprietary rights to the information contained herein this document. It may not be
edited, copied or circulated without prior written agreement by Sigma Designs.
© 2014 Sigma Designs, Inc.
UZB3 Z-Wave USB Adapter
4.2 Start the Z-Wave PC Controller application
You can start the Z-Wave PC Controller using the Start menu. To open the Start menu, click the Start
button in the lower-left corner of your screen. Or, press the Windows logo key on your keyboard. The
Start menu appears.
To open Z-Wave PC Controller, click its icon shown in the left pane of the Start menu that displays the
most frequently used programs list. If you don't see its icon there, click All Programs at the bottom of
the left pane. Instantly, the left pane displays a long list of programs in alphabetical order, followed by a
list of folders. Click Sigma Designs folder, then click Z-Wave PC Controller folder and finally Z-Wave PC
Controller icon.
Each time you start Z-Wave PC Controller, you are actually running the “C:\Program
Files\SigmaDesigns\Z-Wave PC Controller\ZWaveController.exe” executable file, although you do not
usually type its name or even see it.
Run the PC based Controller application, and the Main window will appear as shown below:
Figure 5. 6PC based Controller Main Window
All information are correct at the time of release. Sigma Designs owns the proprietary rights to the information contained herein this document. It may not be
edited, copied or circulated without prior written agreement by Sigma Designs.
© 2014 Sigma Designs, Inc.
UZB3 Z-Wave USB Adapter
4.3 Remove Z-Wave PC Controller application Software
You can uninstall Z-Wave PC Controller from your computer if you no longer use it.
1. Open Add or Remove Programs in Control Panel.
To do it, click Start, then click Control Panel (in Classical View – click Start, then point to
Settings, and click Control Panel), and then double-click Add or Remove Programs.
2. Click the program in the list and then click the Remove button. You can sort programs by
selecting different options in Sort by.
3. Standard confirmation dialog appears. Click Yes to continue the removal of the Z-Wave PC
Controller software.
4. Z-Wave PC Controller and its settings will be removed without prompting you further.
All information are correct at the time of release. Sigma Designs owns the proprietary rights to the information contained herein this document. It may not be
edited, copied or circulated without prior written agreement by Sigma Designs.
© 2014 Sigma Designs, Inc.
UZB3 Z-Wave USB Adapter
4.4 User Interface
The PC Based Controller application Main window (See Figure 3) is divided into the following views:
•
•
•
•
•
•
Title bar
Menu bar
Node
Controller
Command Class
Associations
•
•
•
•
Setup Route
Node Info
Log
Status Bar
3.4.1 Main Menu
On top of the Main window is the Application Main Menu. It has the following items:
Categories Menu
Menu item
Description
Node
Toggle shows the Node section
Controller
Toggle shows the Controller section
Cmd Class
Toggle shows the Command Class section
Associations
Toggle shows the Associations section
Setup Route
Toggle shows the Setup Route section
Log
Toggle shows the Log section
Settings
To detect available serial ports and query them to find all
connected Z-Wave devices
Security Test
Schema
Toggle shows the Security Test Schema tab (only in Z-Wave
Security PC Controller)
ERTT
Toggle shows the ERTT tab
Exit
To exit the application.
All information are correct at the time of release. Sigma Designs owns the proprietary rights to the information contained herein this document. It may not be
edited, copied or circulated without prior written agreement by Sigma Designs.
© 2014 Sigma Designs, Inc.
UZB3 Z-Wave USB Adapter
Help menu
Z-Wave Pc Controller comes with its own built-in Help system. The Help menu includes the items to
access this Help system.
Menu item
Keyboard Shortcut
Index
Contents
Description
Browses Help system by keywords.
F1
Browses Help system by topics.
Search
Opens search tab of the Help system.
About…
Displays the version and short status information of
the application
All information are correct at the time of release. Sigma Designs owns the proprietary rights to the information contained herein this document. It may not be
edited, copied or circulated without prior written agreement by Sigma Designs.
© 2014 Sigma Designs, Inc.
UZB3 Z-Wave USB Adapter
3.4.2 Node View
The Node View contains Menu Bar, Node List and Node information for the selected node.
It is used for operations with nodes.
Figure 7. Node section
All information are correct at the time of release. Sigma Designs owns the proprietary rights to the information contained herein this document. It may not be
edited, copied or circulated without prior written agreement by Sigma Designs.
© 2014 Sigma Designs, Inc.
UZB3 Z-Wave USB Adapter
The Node’s Menu Bar has the following items:
Menu item
Description
NW Inclusion
Network Wide Inclusion, to include all nodes into
network once they have been reset and given power
Add
To Add a node
Remove
To Remove a node
Node Info
To request Node info from a node
Request Node Neighbor Update
To get the neighbors from the specified node.
Set SUC/SIS
To set the “Set SUC” or “Set SIS” command to the
selected Controller
Basic Set On
Send the BASIC SET ON command to Switch a selected
node(s) ON
Toggle Basic Get
Starts/stops sending consequent BASIC GET commands
to the selected node(s)
Basic Set Off
Sends the BASIC SET OFF command to Switch a selected
node(s) OFF
Switch All On
To switch all nodes in the network ON
Switch All Off
To switch all nodes in the network OFF
Send NOP
‘No Operation’ – to send a frame not carrying any
functional info to a node
Numeric box after NOP
To enter the Node ID of the node to which a NOP frame
is to be sent
Is Failed
To send a Failure signal to a node
Replace failed
To Replace a failed node
Remove Failed
To Remove a failed node
Wake Up Interval (Set)
To set up the Wake Up Interval for a non-listening node
All information are correct at the time of release. Sigma Designs owns the proprietary rights to the information contained herein this document. It may not be
edited, copied or circulated without prior written agreement by Sigma Designs.
© 2014 Sigma Designs, Inc.
UZB3 Z-Wave USB Adapter
The Node List has three columns:
•
Node Id – shows the IDs of all nodes in the network;
•
Device Type – shows description of the type of every node in the network;
•
Status – shows the current status of a node.
The Node Info section gives structured information about the selected node. For more information,
please refer to Z-Wave Device Class Specification documentation.
All information are correct at the time of release. Sigma Designs owns the proprietary rights to the information contained herein this document. It may not be
edited, copied or circulated without prior written agreement by Sigma Designs.
© 2014 Sigma Designs, Inc.
UZB3 Z-Wave USB Adapter
3.4.3 Controller View
The Controller view includes Menu Bar, Network Role Option and Controller Information sections.
The Controller view is used for operations with controllers.
Figure 8. Controller view
The Controller’s Menu Bar has the following items:
All information are correct at the time of release. Sigma Designs owns the proprietary rights to the information contained herein this document. It may not be
edited, copied or circulated without prior written agreement by Sigma Designs.
© 2014 Sigma Designs, Inc.
UZB3 Z-Wave USB Adapter
Menu item
Description
Start Learn Mode
Starts learn mode for the controller if it is needed to include it in another
controller’s network
Reset
Resets a controller
Create New Primary
A SUC can create a new Primary Controller in the network if the existing
Primary controller fails
Request Update
An Inclusion controller can request network updates from a SUC or a SIS
Shift
Is used to shift primary role to another controller in the network
Load Command Classes
from device memory
To load command classes from the device memory (previously saved to
device memory)
Save Command Classes
to device memory
To save command classes from the PC Controller application memory to the
Static Controller device memory
The Network Role Option section has controls to assign the role of the SC in the network:
•
SUC – Static Update Server
•
SIS – Static Update Controller with ID server
•
None
General information regarding the SC is displayed in the Controller Information section in the following
items:
Section
Description
Controller ID
Displays the node ID of the PC based SC
Controller Home ID
Displays the current Home ID of the PC based SC
Controller Network Role
Displays the PC based SC network role
Serial Port
Displays the serial port in use.
All information are correct at the time of release. Sigma Designs owns the proprietary rights to the information contained herein this document. It may not be
edited, copied or circulated without prior written agreement by Sigma Designs.
© 2014 Sigma Designs, Inc.
UZB3 Z-Wave USB Adapter
3.4.4 Associations View
The Associations view has a Menu bar, and two fields: Source and Groups. It is used to set up
associations between nodes.
The Menu bar has two items:
Menu item
Description
Create Association
Creates an association between selected nodes
Remove Association
Removes selected association
The Source field shows the list of available source nodes that support the Association command class,
e.g. Binary sensor.
The Groups field shows the association groups that can be or have been created.
The “Assign Return Routes” checkbox is to define whether the Controller shou
should
ld assign return routes
together with setting the association.
Figure 9. Associations view
All information are correct at the time of release. Sigma Designs owns the proprietary rights to the information contained herein this document. It may not be
edited, copied or circulated without prior written agreement by Sigma Designs.
© 2014 Sigma Designs, Inc.
UZB3 Z-Wave USB Adapter
3.4.5 Command Class View
The Command Class view is used to send a specified command class to a selected node. It has the
following items:
•
Command Classes: drop-down list to select a command class;
•
Command Name: drop-down list to select a command name belonging to the selected class;
•
Command Parameters Grid: to enter command parameters.
Figure 10. Command Class view
All information are correct at the time of release. Sigma Designs owns the proprietary rights to the information contained herein this document. It may not be
edited, copied or circulated without prior written agreement by Sigma Designs.
© 2014 Sigma Designs, Inc.
UZB3 Z-Wave USB Adapter
3.4.6 Setup Route View
The Setup Route view has a Menu Bar, Source Node list and Destination Node list. It is used to set up
routes between nodes.
The Menu Bar has two items:
Menu item
Description
Assign
To assign routes via nodes
Delete
To delete assigned routes
Figure 11. Setup Route view
Source Node list and Destination Node list show the lists of source and destination nodes in a routed
network respectively.
All information are correct at the time of release. Sigma Designs owns the proprietary rights to the information contained herein this document. It may not be
edited, copied or circulated without prior written agreement by Sigma Designs.
© 2014 Sigma Designs, Inc.
UZB3 Z-Wave USB Adapter
3.4.7
ERTT
Z-Wave PC Controller has the Enhanced Reliability Test Tool implemented. It can be activated as a tab
through the Categories menu or through Ctrl+E keyboard shortcut.
Figure 12. ERTT
All information are correct at the time of release. Sigma Designs owns the proprietary rights to the information contained herein this document. It may not be
edited, copied or circulated without prior written agreement by Sigma Designs.
© 2014 Sigma Designs, Inc.
UZB3 Z-Wave USB Adapter
3.4.8
Log View
Here output of current actions is recorded. The two tabs, Actions and Packets, show full information
about what is happening within the PC Controller.
Figure 13. Log View
All information are correct at the time of release. Sigma Designs owns the proprietary rights to the information contained herein this document. It may not be
edited, copied or circulated without prior written agreement by Sigma Designs.
© 2014 Sigma Designs, Inc.
UZB3 Z-Wave USB Adapter
3.4.9
Log View
Status Bar displays Home ID, controller node ID and Command queue status.
Figure 14. Status Bar
All information are correct at the time of release. Sigma Designs owns the proprietary rights to the information contained herein this document. It may not be
edited, copied or circulated without prior written agreement by Sigma Designs.
© 2014 Sigma Designs, Inc.
UZB3 Z-Wave USB Adapter
4. FCC NOTICE TO USERS
Federal Communication Commission Interference Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur
in a particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one of the following measures:
FCC Caution
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Any changes or modifications not expressly approved by the party responsible for compliance could void
the user's authority to operate this equipment.
This transmitter must not be co-located or operating in conjunction with any other antenna or
transmitter.
All information are correct at the time of release. Sigma Designs owns the proprietary rights to the information contained herein this document. It may not be
edited, copied or circulated without prior written agreement by Sigma Designs.
© 2014 Sigma Designs, Inc.
UZB3 Z-Wave USB Adapter
5. EU DECLARATION OF CONFORMITY
EU Declaration of Conformity
This device complies with the essential requirements of the R&TTE Directive 1999/5/EC. The following
test methods have been applied in order to prove presumption of conformity with the essential
requirements of the R&TTE Directive 1999/5/EC:
(Safety)
EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013
Safety of Information Technology Equipment
(MPE)
EN 62479:2010
Assessment of the compliance of low power electronic and electrical equipment with the basic
restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz)
(Radio)
EN 300 220-1 V2.4.1:2012
Electromagnetic compatibility and Radio spectrum Matters (ERM); Short Range Devices (SRD);
Radio equipment to be used in the 25MHz to 1000MHz frequency range with power levels ranging
up to 500mW; Part 1: Technical characteristics and test methods
EN 300 220-2 V2.4.1:2012
Electromagnetic compatibility and Radio spectrum Matters (ERM); Short Range Devices (SRD);
Radio equipment to be used in the 25 MHz to 1 000 MHz frequency range with power levels ranging
up to 500 mW; Part 2: Harmonized
Harmonized EN covering essential requirements under article 3.2 of the
R&TTE Directive
(EMC)
EN 301 489-1 V1.9.2:2011
Electromagnetic compatibility and Radio spectrum Matters (ERM);
(ERM); ElectroMagnetic Compatibility
(EMC) standard for radio equipment and services; Part 1: Common technical requirements
EN 301 489-3 V1.6.1:2013
Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility
(EMC) standard for radio equipment and services; Part 3: Specific conditions for Short-Range Devices
(SRD) operating on frequencies between 9 kHz and 246 GHz
0560
All information are correct at the time of release. Sigma Designs owns the proprietary rights to the information contained herein this document. It may not be
edited, copied or circulated without prior written agreement by Sigma Designs.
© 2014 Sigma Designs, Inc.
UZB3 Z-Wave USB Adapter
Česky
[Czech]
[Jméno výrobce] tímto prohlašuje, že tento [typ zařízení] je ve shodě se základními požadavky a
dalšími příslušnými ustanoveními směrnice 1999/5/ES.
Dansk
[Danish]
Undertegnede [fabrikantens navn] erklærer herved, at følgende udstyr [udstyrets
typebetegnelse] overholder de væsentlige krav og øvrige relevante krav i direktiv 1999/5/EF.
Deutsch
[German]
Hiermit erklärt [Name des Herstellers], dass sich das Gerät [Gerätetyp] in Übereinstimmung mit
den grundlegenden Anforderungen und den übrigen einschlägigen Bestimmungen der
Richtlinie 1999/5/EG befindet.
Eesti
[Estonian]
Käesolevaga kinnitab [tootja nimi = name of manufacturer] seadme [seadme tüüp = type of
equipment] vastavust direktiivi 1999/5/EÜ põhinõuetele ja nimetatud direktiivist tulenevatele
teistele asjakohastele sätetele.
English
Hereby, Sigma Designs, declares that UZB3 is in compliance with the essential requirements
and other relevant provisions of Directive 1999/5/EC.
Español
[Spanish]
Por medio de la presente [nombre del fabricante] declara que el [clase de equipo] cumple con
los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva
1999/5/CE.
Ελληνική
[Greek]
ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ [name of manufacturer] ΔΗΛΩΝΕΙ ΟΤΙ [type of equipment]
ΣΥΜΜΟΡΦΩΝΕΤΑΙ ΠΡΟΣ ΤΙΣ ΟΥΣΙΩΔΕΙΣ ΑΠΑΙΤΗΣΕΙΣ ΚΑΙ ΤΙΣ ΛΟΙΠΕΣ ΣΧΕΤΙΚΕΣ ΔΙΑΤΑΞΕΙΣ ΤΗΣ
ΟΔΗΓΙΑΣ 1999/5/ΕΚ.
Français
[French]
Par la présente [nom du fabricant] déclare que l'appareil [type d'appareil] est conforme aux
exigences essentielles et aux autres dispositions pertinentes de la directive 1999/5/CE.
Italiano
[Italian]
Con la presente [nome del costruttore] dichiara che questo [tipo di apparecchio] è conforme ai
requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 1999/5/CE.
Latviski
[Latvian]
Ar šo [name of manufacturer / izgatavotāja nosaukums] deklarē, ka [type of equipment /
iekārtas tips] atbilst Direktīvas 1999/5/EK būtiskajām prasībām un citiem ar to saistītajiem
noteikumiem.
Lietuvių
[Lithuanian]
Šiuo [manufacturer name] deklaruoja, kad šis [equipment type] atitinka esminius reikalavimus ir
kitas 1999/5/EB Direktyvos nuostatas.
All information are correct at the time of release. Sigma Designs owns the proprietary rights to the information contained herein this document. It may not be
edited, copied or circulated without prior written agreement by Sigma Designs.
© 2014 Sigma Designs, Inc.
UZB3 Z-Wave USB Adapter
Nederlands
[Dutch]
Hierbij verklaart [naam van de fabrikant] dat het toestel [type van toestel] in overeenstemming
is met de essentiële eisen en de andere relevante bepalingen van richtlijn
richtlijn 1999/5/EG.
Malti
[Maltese]
Hawnhekk, [isem tal-manifattur], jiddikjara li dan [il-mudel tal-prodott] jikkonforma malħtiġijiet essenzjali u ma provvedimenti oħrajn relevanti li hemm fid
fid--Dirrettiva 1999/5/EC.
Magyar
[Hungarian]
Alulírott, [gyártó neve] nyilatkozom, hogy a [... típus] megfelel a vonatkozó alapvetõ
követelményeknek és az 1999/5/EC irányelv egyéb elõírásainak.
Polski
[Polish]
Niniejszym [nazwa producenta] oświadcza, że [nazwa wyrobu] jest zgodny z zasadniczymi
wymogami oraz pozostałymi stosownymi postanowieniami Dyrektywy 1999/5/EC.
Português
[Portuguese]
[Nome do fabricante] declara que este [tipo de equipamento] está conforme com os requisitos
essenciais e outras disposições da Directiva 1999/5/CE.
Slovensko
[Slovenian]
[Ime proizvajalca] izjavlja, da je ta [tip opreme] v skladu z bistvenimi zahtevami in ostalimi
relevantnimi določili direktive 1999/5/ES.
Slovensky
[Slovak]
[Meno výrobcu] týmto vyhlasuje, že [typ zariadenia] spĺňa základné požiadavky a všetky
príslušné ustanovenia Smernice 1999/5/ES.
Suomi
[Finnish]
[Valmistaja = manufacturer] vakuuttaa täten että [type of equipment = laitteen tyyppimerkintä]
tyyppinen laite on direktiivin 1999/5/EY oleellisten vaatimusten ja sitä koskevien direktiivin
muiden ehtojen mukainen.
Svenska
[Swedish]
Härmed intygar [företag] att denna [utrustningstyp] står I överensstämmelse med de väsentliga
egenskapskrav och övriga relevanta bestämmelser som framgår av direktiv 1999/5/EG.
All information are correct at the time of release. Sigma Designs owns the proprietary rights to the information contained herein this document. It may not be
edited, copied or circulated without prior written agreement by Sigma Designs.
© 2014 Sigma Designs, Inc.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : Yes
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Print, Extract
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Create Date                     : 2016:06:15 15:25:40Z
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2016:06:15 16:02:40+08:00
Metadata Date                   : 2016:06:15 16:02:40+08:00
Format                          : application/pdf
Creator                         : GQuat
Title                           : Microsoft Word - UZB3 User Manual 03 - HMY.docx
Producer                        : GPL Ghostscript 8.15
Document ID                     : uuid:f14f7409-8cb8-4ed0-b6b2-fd36e1fe2b64
Instance ID                     : uuid:84f7e8f5-2f25-44dc-b379-756abe11c7e9
Page Count                      : 27
Author                          : GQuat
EXIF Metadata provided by EXIF.tools
FCC ID Filing: D87-UZB3-HMY

Navigation menu