![Telegesis TG-PM-0511-ETRX358x-LRS r2 ETRX358x-LRS and ETRX358xHR-LRS Product Manual ©2014 Telegesis (UK) Ltd ETRX358x-LRS Product Manual ETRX358x-LRS ZIGBEE® MODULES PRODUCT MANUAL](https://usermanual.wiki/Silicon-Laboratories-Finland/EM358L/User-Guide-2267485-Page-1.png)
![ETRX358x-LRS and ETRX358xHR-LRS ©2014 Telegesis (UK) Ltd - 2 - ETRX358x-LRS Product Manual Table of Contents 1 INTRODUCTION ................................................................................................................. 5 1.1 Hardware Description ....................................................................................................... 5 2 PRODUCT APPROVALS ................................................................................................... 7 2.1 FCC Approvals ................................................................................................................. 7 2.1.1 FCC Labelling Requirements ........................................................................................... 8 2.2 IC (Industry Canada) Approvals ....................................................................................... 8 2.2.1 IC Labelling Requirements ............................................................................................... 9 2.3 European Certification .................................................................................................... 10 2.4 Declarations of Conformity ............................................................................................. 10 2.5 IEEE 802.15.4 ................................................................................................................ 10 2.6 The ZigBee Protocol ...................................................................................................... 11 3 MODULE PINOUT ............................................................................................................ 12 4 HARDWARE DESCRIPTION ............................................................................................ 14 4.1 Hardware Interface ......................................................................................................... 14 5 FIRMWARE DESCRIPTION ............................................................................................. 15 5.1 Token Settings ............................................................................................................... 16 5.2 Custom Firmware ........................................................................................................... 16 5.3 Boost Mode vs. Normal Mode ........................................................................................ 16 5.4 Software Interface .......................................................................................................... 17 6 ABSOLUTE MAXIMUM RATINGS ................................................................................... 18 6.1 Environmental Characteristics ........................................................................................ 18 6.2 Recommended Operating Conditions............................................................................. 18 7 DC ELECTRICAL CHARACTERISTICS ........................................................................... 19 8 DIGITAL I/O SPECIFICATIONS ....................................................................................... 21 9 A/D CONVERTER CHARACTERISTICS .......................................................................... 22 10 AC ELECTRICAL CHARACTERISTICS ........................................................................... 22 10.1 TX Power Characteristics ............................................................................................... 24 10.2 Power Settings for Regulatory Compliance .................................................................... 25 10.3 Temperature behaviour .................................................................................................. 26 11 PHYSICAL DIMENSIONS ................................................................................................. 27 12 RECOMMENDED REFLOW PROFILE ............................................................................. 28 13 PRODUCT LABEL DRAWING ......................................................................................... 29 14 RECOMMENDED FOOTPRINT ........................................................................................ 30 14.1 Recommended Placement ............................................................................................. 32 14.2 Example carrier board .................................................................................................... 34 15 RELIABILITY TESTS ........................................................................................................ 35](https://usermanual.wiki/Silicon-Laboratories-Finland/EM358L/User-Guide-2267485-Page-2.png)
![ETRX358x-LRS and ETRX358xHR-LRS ©2014 Telegesis (UK) Ltd - 3 - ETRX358x-LRS Product Manual 16 APPLICATION NOTES ..................................................................................................... 35 16.1 Safety Precautions ......................................................................................................... 35 16.2 Design Engineering Notes .............................................................................................. 35 16.3 Storage Conditions ......................................................................................................... 36 17 PACKAGING .................................................................................................................... 37 17.1 Embossed Tape ............................................................................................................. 37 17.2 Component Orientation .................................................................................................. 38 17.3 Reel Dimensions ............................................................................................................ 38 17.4 Packaging ...................................................................................................................... 39 18 ORDERING INFORMATION ............................................................................................. 40 19 TRADEMARKS ................................................................................................................. 41 20 DISCLAIMER .................................................................................................................... 41 21 ROHS DECLARATION ..................................................................................................... 41 22 DATA SHEET STATUS .................................................................................................... 41 23 LIFE SUPPORT POLICY .................................................................................................. 41 24 RELATED DOCUMENTS ................................................................................................. 42 25 CONTACT INFORMATION ............................................................................................... 42](https://usermanual.wiki/Silicon-Laboratories-Finland/EM358L/User-Guide-2267485-Page-3.png)
![ETRX358x-LRS and ETRX358x-LRS ©2014 Telegesis (UK) Ltd - 4 - ETRX358x-LRS Product Manual The Telegesis ETRX358x-LRS and ETRX358xHR-LRS modules are low power 2.4GHz ZigBee modules with an added frontend module (SiGe SE2432L) containing both PA and LNA for highest possible link budget. Based on the latest Ember EM358x family of single chip ZigBee solutions the new long range modules are footprint compatible with the entire Telegesis ETRX3 family, thus representing a drop-in replacement for all applications where a high link budget is required. The module’s unique AT-style command line interface allows designers to quickly integrate ZigBee technology without complex software engineering. For custom application development the ETRX358x series integrates with ease into Ember’s InSight development environment. Image not shown actual size; enlarged to show detail. Module Features • Small form factor, SMT module 25mm x 19mm • Same footprint and pin-out as ETRX357-LRS • Side Castellations for easy soldering and inspection • Two antenna options: Integrated chip antenna or U.FL coaxial connector • Based on 32-bit ARM® Cortex-M3 • Industry standard JTAG Programming and real time network level debugging via the Ember Debug Port • Up to 512kB of flash and 64kbytes of RAM • Lowest Deep Sleep Current of sub 1µA with retained RAM and GPIO and multiple sleep modes • Ultra Wide supply voltage range (2.1 to 3.6V) • Optional 32.768kHz watch crystal can be added externally • Module ships with standard Telegesis AT-style command interface based on the ZigBee PRO feature set • Can act as an End Device, Router or Coordinator • 22 general-purpose I/O lines including analogue inputs • Firmware upgrades via serial port or over the air (password protected) • Hardware supported encryption (AES-128) • CE and FCC and IC compliance, IC and FCC modular approval • Operating temperature range: -40°C to +85°C • Standard version without LNA and PA available in the same form factor Radio Features • Based on the Silicon Labs EM358x family of single chip ZigBee® SoCs • 2.4GHz ISM Band • 250kbit/s over the air data rate – NB: actual usable data throughput with ZigBee is about 20kbps • 15 channels (IEEE802.15.4 Channel 11 to 25) • SiGe SE2432L integrated PA and LNA • +20dBm output power (adjustable down to -41dBm) • High sensitivity of -106dBm typ. @ 1% packet error rate • RX Current: 33mA, TX Current: approx 140mA at 20dBm • Robust Wi-Fi and Bluetooth coexistence Suggested Applications • ZigBee Smart Energy applications • Wireless Alarms and Security • Home/Building Automation • Wireless Sensor Networks • M2M Industrial Controls • Lighting and ventilation control • Remote monitoring • Environmental monitoring and control Development Kit • Enhancement kit available to upgrade existing Telegesis and Ember development kits to be used with the new ETRX358x family • AT-style software interface command dictionary can be modified for high volume customers. • Custom software development available upon request. Example AT-Style Commands AT+BCAST Send a Broadcast AT+UCAST:<address> Send a Unicast AT+EN Establish PAN network AT+JN Join PAN At power-up the last configuration is loaded from non- volatile S-Registers, which can eliminate the need for an additional host controller.](https://usermanual.wiki/Silicon-Laboratories-Finland/EM358L/User-Guide-2267485-Page-4.png)
![ETRX358x-LRS and ETRX358x-LRS ©2014 Telegesis (UK) Ltd - 5 - ETRX358x-LRS Product Manual 1 Introduction This document describes the Telegesis ETRX358x-LRS and ETRX358xHR-LRS ZigBee long range modules which have been designed to be easily integrated into another device and to provide a fast, simple and low cost wireless mesh networking interface. The Telegesis ETRX3 series modules are based on the Silicon Labs ZigBee compliant platform consisting of the single chip family of EM358x SoCs combined with the ZigBee PRO compliant EmberZNet meshing stack. Integration into a wide range of applications is made easy using a simple AT style command interface and advanced hardware design. The configurable functionality of the Telegesis AT Commandset often allows the ETRX3 series ZigBee modules to be used without an additional host microcontroller saving even more integration time and costs. In addition to the Telegesis AT Commandset, the ETRX358x-LRS and ETRX358xHR-LRS modules can be used with custom-built firmware whilst representing an ideal platform for custom firmware development in conjunction with the Silicon Labs ZigBee development kits. No RF experience or expertise is required to add this powerful wireless networking capability to your products. The ETRX358x-LRS and ETRX358xHR-LRS offer fast integration opportunities and the shortest possible time to market for your product. 1.1 Hardware Description The main building blocks of the ETRX358x-LRS and ETRX358xHR-LRS are the single chip EM358x SoC from Silicon Labs, a SiGe SE2432L frontend module combining a Power Amplifier with a Low Noise Amplifier, a 24MHz reference crystal and RF front-end circuitry optimized for best RF performance. The modules are available with on-board antenna or alternatively a U.FL connector for attaching external antennae. Modules with the U.FL connector are identified by the “HR” suffix. The integrated antenna is an Antenova Rufa, and details of the radiation pattern and further data are available from the Antenova website [5]. Module Chip Flash RAM Antenna USB ETRX3581-LRS1 EM3581 256kB 32kB Chip No ETRX3581HR-LRS 1 EM3581 256kB 32kB External No ETRX3582-LRS 1 EM3582 256kB 32kB Chip Yes ETRX3582HR-LRS 1 EM3582 256kB 32kB External Yes ETRX3585-LRS 1 EM3585 512kB 32kB Chip No ETRX3585HR-LRS 1 EM3585 512kB 32kB External No ETRX3586-LRS 1 EM3586 512kB 32kB Chip Yes ETRX3586HR-LRS 1 EM3586 512kB 32kB External Yes ETRX3587-LRS EM3587 512kB 64kB Chip No ETRX3587HR-LRS EM3587 512kB 64kB External No ETRX3588-LRS 1 EM3588 512kB 64kB Chip Yes ETRX3588HR1 EM3588 512kB 64kB External Yes Table 1: Memories 1 MOQ and Lead Time applies. Only stocked modules are ETRX3587 and ETRX3587HR](https://usermanual.wiki/Silicon-Laboratories-Finland/EM358L/User-Guide-2267485-Page-5.png)
![ETRX358x-LRS and ETRX358x-LRS ©2014 Telegesis (UK) Ltd - 6 - ETRX358x-LRS Product Manual The LNA and RF power amplifier of the LRS devices improve the output power by 12dB and the sensitivity by 5dB which will increase the range by approximately 700% relative to the standard devices (where local regulations permit the use of the maximum output power). The ETRX358x and ETRX358xHR are used for ZigBee (www.zigbee.org) applications. In case it is desired to develop custom firmware instead of using the pre-loaded AT-Command interface, the Silicon Labs toolchain, consisting of Ember Desktop together with a comprehensive integrated development environment (IDE), is required.](https://usermanual.wiki/Silicon-Laboratories-Finland/EM358L/User-Guide-2267485-Page-6.png)
![ETRX358x-LRS and ETRX358x-LRS ©2014 Telegesis (UK) Ltd - 7 - ETRX358x-LRS Product Manual 2 Product Approvals The ETRX358x-LRS and ETRX358xHR-LRS have been designed to meet all national regulations for world-wide use. In particular the following certifications have been obtained: 2.1 FCC Approvals The Telegesis ETRX358x-LRS family with integrated Antenna as well as the ETRX358xHR-LRS family including the antennas listed in able 2 and the power levels listed in section 10.2 have been tested to comply with FCC CFR Part 15 (USA) The devices meet the requirements for modular transmitter approval as detailed in the FCC public notice DA00.1407.transmitter. FCC statement: This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This module complies with the USA SAR requirements and is not intended to be operated within 20cm of the body. The following statement must be included as a CAUTION statement in manuals for OEM products to alert users on FCC RF exposure compliance “WARNING: To satisfy FCC RF exposure requirements for mobile transmitting devices, a separation distance of 20cm or more should be maintained between the antenna of this device and persons during operation. To ensure compliance, operations at closer distances than this are not recommended.” Item Part No. Manufacturer Type Impedance Gain 1 BT-Stubby (straight) EAD Ltd. [6] ¼ Wave 50Ω 0dBi 2 BT-Stubby (right-angle) EAD Ltd. [6] ¼ Wave 50Ω 0dBi 3 CJ-2400-6603 Chang Jia ½ Wave 50 Ω 2.0dBi 4 Rufa (on board) Antenova Chip 50Ω 2.1dBi (peak) Table 2. Approved Antennae An end user deploying an ETRX358x-LRS or an ETRX358xHR-LRS module together with an antenna as listed in Table 2 is not required to obtain a new authorization for the module – BUT this does not preclude the possibility that some other form of authorization or testing may be required for the end product depending upon local territorial regulations. The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by Telegesis (UK) Ltd. may void the user's authority to operate the equipment. When using the ETRX358x-LRS with approved antennae, it is required to prevent end-users from replacing them with non-approved ones. FCC ID: S4GEM358L](https://usermanual.wiki/Silicon-Laboratories-Finland/EM358L/User-Guide-2267485-Page-7.png)
![ETRX358x-LRS and ETRX358x-LRS ©2014 Telegesis (UK) Ltd - 8 - ETRX358x-LRS Product Manual The antenna(s) must be installed such that a minimum separation distance of 20cm is maintained between the radiator (antenna) and all persons at all times. 2.1.1 FCC Labelling Requirements When integrating the ETRX358x-LRS or ETRX358xHR-LRS families into a product it must be ensured that the FCC labelling requirements are met. This includes a clearly visible label on the outside of the finished product specifying the Telegesis FCC identifier (FCC ID: S4GEM358L) as well as the notice above. This exterior label can use wording such as “Contains Transmitter Module FCC ID: S4GEM358L” or “Contains FCC ID: S4GEM358L” although any similar wording that expresses the same meaning may be used. 2.2 IC (Industry Canada) Approvals The Telegesis ETRX358x-LRS family with integrated Antenna as well as the ETRX358xHR-LRS family have been approved by Industry Canada to operate with the antenna types listed in Table 2 with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. IC-ID: 8735A-EM358L • This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. • Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that permitted for successful communication. • To comply with Industry Canada RF radiation exposure limits for general population, the antenna(s) used for this transmitter must be installed such that a minimum separation distance of 20cm is maintained between the radiator (antenna) and all persons at all times and must not be co-located or operating in conjunction with any other antenna or transmitter • This device has been designed to operate with the antennas listed in Table 2, and having a maximum gain of 2.1 dBi. Antennas not included in this list or having a gain greater than 2.1 dBi are strictly prohibited for use with this device. The required antenna impedance is 50 ohms. French Statements • Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain](https://usermanual.wiki/Silicon-Laboratories-Finland/EM358L/User-Guide-2267485-Page-8.png)
![ETRX358x-LRS and ETRX358x-LRS ©2014 Telegesis (UK) Ltd - 9 - ETRX358x-LRS Product Manual de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante. • Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. OEM Responsibilities The ETRX358x-LRS and ETRX358x-LRS families of module have been certified for integration into products only by OEM integrators under the following conditions: 1. The antenna(s) must be installed such that a minimum separation distance of 20cm is maintained between the radiator (antenna) and all persons at all times. 2. The transmitter module must not be co-located or operating in conjunction with any other antenna or transmitter. As long as the two conditions above are met, further transmitter testing will not be required. However, the OEM integrator is still responsible for testing their end-product for any additional compliance requirements required with this module installed (for example, digital device emissions, PC peripheral requirements, etc.). IMPORTANT NOTE: In the event that these conditions can not be met (for certain configurations or co-location with another transmitter), then Industry Canada certification is no longer considered valid and the IC Certification Number can not be used on the final product. In these circumstances, the OEM integrator will be responsible for re-evaluating the end product (including the transmitter) and obtaining a separate Industry Canada authorization. 2.2.1 IC Labelling Requirements The ETRX358x-LRS and ETRX358xHR-LRS family modules are labelled with its own IC Certification Number. If the IC Certification Number is not visible when the module is installed inside another device, then the outside of the device into which the module is installed must also display a label referring to the enclosed module. In that case, the final end product must be labelled in a visible area with the following: “Contains Transmitter Module IC: 8735A-EM358L” or “Contains IC: 8735A-EM358L” The OEM of the ETRX358x-LRS and ETRX358xHR-LRS family modules must only use the approved antenna(s) listed above, which have been certified with this module. The OEM integrator has to be aware not to provide information to the end user regarding how to install or remove this RF module or change RF related parameters in the user’s manual of the end product.](https://usermanual.wiki/Silicon-Laboratories-Finland/EM358L/User-Guide-2267485-Page-9.png)
![ETRX358x-LRS and ETRX358x-LRS ©2014 Telegesis (UK) Ltd - 10 - ETRX358x-LRS Product Manual 2.3 European Certification The ETRX358x and ETRX358xHR families are at a maximum power level of 21.15mW e.i.r.p. (13.2dBm) compliant to the following standards: • Radio: EN 300 328:V1.8.1 • EMC: EN 301 489-17:V2.2.1 • Safety: EN 60950-1:2006/A12:2011 All tests have been conducted with the antennae listed in Table 2. If the ETRX358x-LRS and ETRX358xHR-LRS families of modules are incorporated into an OEM product, the OEM product manufacturer must ensure compliance of the final product to the European Harmonised EMC, and low voltage/safety standards. A Declaration of Conformity must be issued for each of these standards and kept on file as described in the R&TTE Directive. The final product must not exceed the specified power ratings, antenna specifications and installation requirements as specified in this user manual. If any of these specifications are exceeded in the final product then a submission must be made to a notified body for compliance testing to all of the required standards. The ‘CE’ marking must be applied to a visible location on any OEM product. For more information please refer to http://ec.europa.eu/enterprise/faq/ce-mark.htm. Customers assume full responsibility for learning and meeting the required guidelines for each country in their distribution market. 2.4 Declarations of Conformity Telegesis (UK) Ltd has issued Declarations of Conformity for all ETRX3 series ZigBee RF Modules, which cover Radio Emissions, EMC and Safety. These documents will be available from our website or on request 2.5 IEEE 802.15.4 IEEE 802.15.4 is a standard for low data rate, wireless networks (raw bit-rate within a radio packet of 250kbps @2.4GHz) which focuses on low cost, low duty cycle, long primary battery life applications as well as mains-powered applications. It is the basis for the open ZigBee Protocol.](https://usermanual.wiki/Silicon-Laboratories-Finland/EM358L/User-Guide-2267485-Page-10.png)
![ETRX358x-LRS and ETRX358x-LRS ©2014 Telegesis (UK) Ltd - 11 - ETRX358x-LRS Product Manual 2.6 The ZigBee Protocol The ZigBee Protocol is a set of standards for wireless connectivity for use between any devices over short to medium distances. The specification was originally ratified in December 2004, paving the way for companies to start making low-power networks a reality. ZigBee uses an IEEE 802.15.4 radio specification running on the 2.4GHz band, plus three additional layers for networking, security and applications. What makes the specification unique is its use of a mesh network architecture which, in bucket chain style, passes data from one node to the next until it lands at its destination. The network is self-healing and adapts its routing as link quality changes or nodes move. Furthermore, nodes can be defined as End Devices which do not act as routers, but can therefore be put into a low-power sleep state. The enhanced version of the ZigBee standard (or ZigBee 2006) was released in December 2006, adding new features and improvements to the only global wireless communication standard enabling the development of easily deployable low-cost, low-power, monitoring and control products for homes, commercial buildings and industrial plant monitoring. In 2007 the ZigBee Alliance introduced the PRO feature-set which offers advantages over earlier feature-sets, including • Truly self-healing mesh networking • Messages can now travel up to 30 hops • Source-Routing for improved point to multipoint message transmission • Improved security including Trust-Centre link keys • New message types and options The Telegesis AT Command-set, which by default ships on all ETRX3 series products is based on the ZigBee PRO feature-set. For more information on the Telegesis AT Command-set please refer to the separate documentation at www.telegesis.com.](https://usermanual.wiki/Silicon-Laboratories-Finland/EM358L/User-Guide-2267485-Page-11.png)
![ETRX358x-LRS and ETRX358x-LRS ©2014 Telegesis (UK) Ltd - 12 - ETRX358x-LRS Product Manual 3 Module Pinout Figure 1. ETRX3 series Module Pinout (top view) The table below gives details about the pin assignment for direct SMD soldering of the ETRX3 series modules to the application board. For more information on the alternate functions please refer to [2]. Also refer to the Telegesis AT Command-set documentation to understand how the pre-programmed firmware makes use of the individual I/Os. All GND pads are connected within the module, but for best RF performance all of them should be grounded externally. ETRX358x pad Name Default Use Alternate function EM35x pin Alternate functions 1 GND GND GND 2 TX_ACTIVE{1} I/O 11 TX_ACTIVE. PC5 of the EM35x is used to control the FEM 3 PC6 I/O 13 OSC32B, nTX_ACTIVE 4 PC7 I/O 14 OSC32A, OSC32_EXT 5 PA7 {5} I/O 18 TIM1C4 6 PB3 {2,3} I/O CTS 19 SC1nCTS, SC1SCLK, TIM2C3 7 nReset {5} nReset 12 8 PB4 {2} I/O RTS 20 TIM2C4, SC1nRTS, SC1nSSEL 9 PA0 I/O 21 TIM2C1, SC2MOS,USBDM{7}I 10 PA1 I/O 22 TIM2C3, SC2SDA, SC2MISO,USBDP{7} 11 PA2 I/O 24 TIM2C4, SC2SCL, SC2SCLK 12 PA3 I/O 25 SC2nSSEL, TRACECLK, TIM2C2 13 GND GND GND 14 PA4 I/O 26 ADC4, PTI_EN, TRACEDATA 15 PA5 {4} I/O 27 ADC5, PTI_DATA, nBOOTMODE, TRACEDATA3 16 PA6 {5} I/O 29 TIM1C3 17 PB1{3} TXD 30 SC1MISO, SC1MOSI, SC1SDA, SC1TXD, TIM2C1 18 PB2{3} RXD 31 SC1MISO, SC1MOSI, SC1SCL, SC1RXD, TIM2C2](https://usermanual.wiki/Silicon-Laboratories-Finland/EM358L/User-Guide-2267485-Page-12.png)
![ETRX358x-LRS and ETRX358x-LRS ©2014 Telegesis (UK) Ltd - 13 - ETRX358x-LRS Product Manual ETRX358x pad Name Default Use Alternate function EM35x pin Alternate functions 19 GND GND GND 20 GND GND GND 21 JTCK JTCK 32 SWCLK 22 PC2 I/O 33 JTDO, SWO 23 PC3 I/O 34 JTDI 24 PC4 I/O 35 JTMS, SWDIO 25 N/C{1} N/C 36 PB0 of the EM35x is used to control the FEM 26 PC1 I/O ADC3 38 ADC3, SWO, TRACEDATA0 27 PC0 {5} I/O 40 JRST, IRQD, TRACEDATA1 28 PB7 {5} I/O ADC2 41 ADC2, IRQC, TIM1C2 29 PB6 {5} I/O ADC1 42 ADC1, IRQB, TIM1C1 30 PB5 I/O ADC0 43 ADC0, TIM2CLK, TIM1MSK 31 GND GND GND 32 Vcc Vcc Vcc 33 GND GND GND Table 3. Pin Information Notes: {1} Pins PB0 and PC5 of the EM357 are used internally to control the front-end module. PB0 is not available to the user. {2} The serial UART connections TXD, RXD, CTS and RTS are PB1, PB2, PB3 and PB4 respectively {3} When using the Telegesis AT Command-set, RTS/CTS handshaking is selectable in firmware. See the AT Command Manual. {4} If PA5 is driven low at power-up or reset the module will boot up in the bootloader {5} PA6, PA7, PB6, PB7 and PC0 can drive high current (see section 8) {6} nRESET is level-sensitive, not edge-sensitive. The module is held in the reset state while nRESET is low. This signal has a 30kΩ Pull-Up. {7} ETRX3588, ETRX3586, ETRX3582 and ETRX3588HR, ETRX3586HR, ETRX3582HR variants only Alternate functions depend on the firmware, but the Telegesis R3xx AT Command-set functions are indicated here for convenience. Important Note: The ETRX358x series and the ETRX358x-LRS series of modules are footprint compatible, but on the ETRX358x-LRS series pins PB0 and PC5 of the EM358x are used internally to control the front-end module and are not available to the user. PC5 is still available on Pad2, but it is configured as TX_ACTIVE signal and cannot be used as a general purpose GPIO. See also the table “Module pads and functions” in the ETRX357 Development Kit Product Manual. Refer to the Silicon Labs EM358x manual for details of the alternate functions and pin names.](https://usermanual.wiki/Silicon-Laboratories-Finland/EM358L/User-Guide-2267485-Page-13.png)
![ETRX358x-LRS and ETRX358x-LRS ©2014 Telegesis (UK) Ltd - 14 - ETRX358x-LRS Product Manual 4 Hardware Description 24MHz EM358x I/O UART I / O programming 5 JTAG Vcc Vreg RESET RESET Match integrated antenna U.FL socket rf terminal selection, filtering and matching circuitry LDO 1V8 1,8Vdc A/D LDO 1V25 Match FEM USB* *not available on all Types Figure 2. Hardware Diagram The ETRX358x-LRS and ETRX358x-LRS are based on the Silicon Labs EM358x family of ZigBee SoCs in addition to a frontend module containing a PA, LNA and RF switch in addition to the RF-frontend circuitry. The EM358x family of ZigBee SoCs are fully integrated 2.4GHz ZigBee transceivers with a 32-bit ARM® Cortex M3TM microprocessor, flash and RAM memory, and peripherals. The industry standard serial wire and JTAG programming and debugging interfaces together with the standard ARM system debug components help to streamline any custom software development. In addition to this a number of MAC functions are also implemented in hardware to help maintain the strict timing requirements imposed by the ZigBee and IEEE802.15.4 standards. The new advanced power management features allow faster wakeup from sleep and new power-down modes allow this 3rd generation module to offer a longer battery life than any 2nd generation modules on the market. The EM358x has fully integrated voltage regulators for both required 1.8V and 1.25V supply voltages. The voltages are monitored (brown-out detection) and the built in power-on-reset circuit eliminates the need for any external monitoring circuitry. A 32.768kHz watch crystal can be connected externally to pads 3 and 4 in case more accurate timing is required. 4.1 Hardware Interface All GPIO pins of the EM358x chips are accessible on the module’s pads. Whether signals are used as general purpose I/Os, or assigned to a peripheral function like ADC is set by the firmware. When using the Telegesis AT Commandset please refer to the AT Commandset manual and the development kit manual for this information and when developing custom firmware please refer to the EM358x datasheet [2].](https://usermanual.wiki/Silicon-Laboratories-Finland/EM358L/User-Guide-2267485-Page-14.png)
![ETRX358x-LRS and ETRX358x-LRS ©2014 Telegesis (UK) Ltd - 15 - ETRX358x-LRS Product Manual 5 Firmware Description By default, the modules will be pre-loaded with a standalone bootloader which supports over-the-air bootloading as well as serial bootloading of new firmware. In order to enter the standalone bootloader using a hardware trigger pull PA5 to ground and power-cycle or reset the module. To avoid entering the standalone bootloader unintentionally make sure not to pull this pin down during boot-up unless the resistance to ground is >10kΩ. (A pull-up is not required). In addition to the standalone bootloader the modules also contain the current release of the Telegesis AT-style command interface as described in the Telegesis AT command dictionary and the Telegesis user guide. Check www.telegesis.com for updates. Each module comes with a unique 64-bit 802.15.4 identifier which is stored in non-volatile memory. The commands and responses pass through the serial port of the ETRX358x as ASCII text, so a simple terminal application will usually suffice. We provide Telegesis Terminal for interaction with the module but it is not an essential feature. The pre-loaded AT-style command interface firmware is based on the EmberZNet PRO meshing stack which implements routers/coordinators as well as (sleepy) end devices. [End devices have no routing responsibility and therefore are allowed to go to sleep, whilst still being able to send and receive messages via a parent router. In addition to classical sleepy and non-sleepy end devices the module firmware also supports mobile (sleepy) end devices capable of changing their parent quickly whenever they change their position within the network.] A router is typically a mains powered device whilst a sleepy end device (SED) can be battery powered. The module is also able to act as a coordinator and Trust Centre through external host control. The AT style command line supplies all the tools required to set up and manage a ZigBee network by allowing easy access to the low-level functionality of the stack. The Telegesis firmware uses the meshing and self-healing EmberZNet PRO stack to overcome many of the limitations of the tree network topology of the ZigBee 2006 stack by using the ZigBee PRO featureset. The Telegesis firmware allows low-level access to physical parameters such as channel and power level. Parameters that define the functionality of the ETRX358x module and also allow standalone functionality are saved in non-volatile memory organised in so-called S-Registers. The SPI and I2C buses are not supported by the current firmware release, but can be used with custom firmware.](https://usermanual.wiki/Silicon-Laboratories-Finland/EM358L/User-Guide-2267485-Page-15.png)
![ETRX358x-LRS and ETRX358x-LRS ©2014 Telegesis (UK) Ltd - 16 - ETRX358x-LRS Product Manual 5.1 Token Settings The ETRX358x-LRS Series Modules’ manufacturing tokens will be pre-programmed with the settings shown in the table below. Token Description TG Default MFG_CIB_OBS Option Bytes <not written> MFG_CUSTOM_VERSION Optional Version Number <not written> MFG_CUSTOM_EUI_64 Custom EUI <not written> MFG_STRING Device Specific String TELEGESIS MFG_BOARD_NAME Hardware Identifier <Order Code> MFG_MANUF_ID Manufacturer ID 0x1010 MFG_PHY_CONFIG Default Power Settings 0xFFFD MFG_BOOTLOAD_AES_KEY Bootloader Key <not written> MFG_EZSP_STORAGE EZSP related <not written> MFG_CBKE_DATA SE Security <not written> MFG_INSTALLATION_CODE SE Installation <not written> MFG_OSC24M_BIAS_TRIM Crystal Bias <not written> MFG_SYNTH_FREQ_OFFSET Frequency offset <not written> MFG_OSC24M_SETTLE_DELAY Crystal Stabilizing Time <not written> MFG_SECURITY_CONFIG Security Settings <not written> MFG_CCA_THRESHOLD CCA Threshold 0xFEBF MFG_SECURE_BOOTLOADER_KEY Secure Bootloader Key <not written> Table 4. Manufacturing tokens 5.2 Custom Firmware For high volume customers the firmware can be customised on request. In addition to this the ETRX358x-LRS series of modules is an ideal platform for developing custom firmware. In order to develop custom firmware the Silicon Labs Ember toolchain is required. When writing firmware for the ETRX358x-LRS it is important to ensure that pins PB0 and PC5 are correctly configured in order that the RF front-end module can operate correctly. An application note “Writing customised firmware for the ETRX35x-LRS” can be downloaded from the Telegesis website. 5.3 Boost Mode vs. Normal Mode The Ember EM358x chips support a “boost mode” power setting next to the “normal mode” power setting. The “boost mode” setting increases the sensitivity and output power of the radio transceiver, however with the LRS variants enabling boost mode has no positive effect on neither the output power nor the sensitivity and therefore it is recommended to not use boost mode on this platform. The Telegesis AT Command-set firmware automatically disables boost mode on LRS series modules and adjusts the power maximum power settings. Section 10.2 lists the requirements for the maximum power settings for use of the LRS family in different countries.](https://usermanual.wiki/Silicon-Laboratories-Finland/EM358L/User-Guide-2267485-Page-16.png)
![ETRX358x-LRS and ETRX358x-LRS ©2014 Telegesis (UK) Ltd - 17 - ETRX358x-LRS Product Manual 5.4 Software Interface Using the default firmware the ETRX358x-LRS is controlled using a simple AT-style command interface and (mostly) non-volatile S-Registers. In order to get a full listing of all the available AT-Commands, please refer to the AT command dictionary document which corresponds to the firmware revision you intend to use. In addition to the command dictionary there are user guides explaining the features of the firmware in more detail. If you need to find out which firmware resides on your module simply type “ATI” followed by a carriage return and you will be prompted with the module’s manufacturing information. The Development Kit manual describes how to upgrade the firmware either via a serial link or over the air.](https://usermanual.wiki/Silicon-Laboratories-Finland/EM358L/User-Guide-2267485-Page-17.png)
![ETRX358x-LRS and ETRX358x-LRS ©2014 Telegesis (UK) Ltd - 18 - ETRX358x-LRS Product Manual 6 Absolute Maximum Ratings No. Item Symbol Absolute Maximum Ratings Unit 1 Supply voltage VCC -0.3 to +3.6 Vdc 2 Voltage on any Pad Vin -0.3 to VCC +0.3 Vdc 3 Voltage on any Pad pin (PA4, PA5, PB5, PB6, PB7, PC1), when used as an input to the general purpose ADC with the low voltage range selected Vin -0.3 to +2.0 Vdc 4 Storage temperature range Tstg -40 to +105 °C 5 Operating temperature range Top -40 to +85 °C 6 Input RF level Pmax +6 dBm 8 Reflow temperature TDeath Please refer to chapter 12 °C Table 5: Absolute Maximum Ratings The absolute maximum ratings given above should under no circumstances be violated. Exceeding one or more of the limiting values may cause permanent damage to the device. Caution! ESD sensitive device. Precautions should be used when handling the device in order to prevent permanent damage. 6.1 Environmental Characteristics No. Item Symbol Absolute Maximum Ratings Unit 1 ESD on any pad according to Human Body Model (HBM) circuit description VTHHBM ±2 kV 2 ESD on non-RF pads according to Charged Device Model (CDM) circuit description VTHCDM ±400 V 3 ESD on RF terminal (HBM) VTHCDM 1000 V 4 Moisture Sensitivity Level MSL MSL3, per J-STD-033 Table 6: Absolute Maximum Ratings 6.2 Recommended Operating Conditions No. Item Condition / Remark Symbol Value Unit Min Typ Max 1 Supply voltage VCC 2.1 3.0 3.6 Vdc 2 RF Input Frequency fC 2405 2480 MHz 3 RF Input Power pIN 0 dBm 4 Operating temperature range Top -40 +85 °C Table 7. Recommended Operating Conditions](https://usermanual.wiki/Silicon-Laboratories-Finland/EM358L/User-Guide-2267485-Page-18.png)
![ETRX358x-LRS and ETRX358x-LRS ©2014 Telegesis (UK) Ltd - 19 - ETRX358x-LRS Product Manual 7 DC Electrical Characteristics VCC = 3.0V, TAMB = 25°C, NORMAL MODE (non-Boost) unless otherwise stated No. Item Condition / Remark Symbol Value Unit Min Typ Max 1 Module supply voltage VCC 2.1 3.6 Vdc Deep Sleep Current 2 Quiescent current, internal RC oscillator disabled, 4kB RAM retained ISLEEP 1.0 µA 3 Quiescent current, internal RC oscillator enabled 4kB RAM retained ISLEEP 1.25 µA 4 Quiescent current, including 32.768kHz oscillator 4kB RAM retained ISLEEP 1.6 µA 5 Quiescent current including internal RC oscillator and 32.768kHz oscillator 4kB RAM retained ISLEEP 1.9 µA 6 Additional current per 4kB block of RAM retained IRAMSLEEP 0,067 µA Reset Current 7 Quiescent current nReset asserted IRESET 2 3 mA Processor and Peripheral Currents 8 ARM® CortexTM M3, RAM and flash memory 25°C, 12MHz Core clock IMCU 7.5 mA 9 ARM® CortexTM M3, RAM and flash memory 25°C, 24MHz Core clock IMCU 8.5 mA 10 ARM® CortexTM M3, RAM and flash memory sleep current 25°C, 12MHz Core clock IMCU 4.0 mA 11 ARM® CortexTM M3, RAM and flash memory sleep current 25°C, 6MHz Core clock IMCU 2.5 mA 12 Serial controller current Per serial controller at max. clock rate ISC 0.2 mA 13 General purpose timer current Per timer at max. clock rate ITIM 0.25 mA 14 General purpose ADC current Max. Sample rate, DMA IADC 1.1 mA 15 USB Active Current IUSB 1 mA 16 USB Suspend Mode Current IUSBSUSP 2.5 mA RX Current 17 LNA,Radio receiver MAC and Baseband ARM® CortexTM M3 sleeping. IRX 26.5 mA 18 Receive current consumption Total, 12MHz clock speed IRX 30 mA 19 Receive current consumption Total, 24MHz clock speed IRX 31.5 mA](https://usermanual.wiki/Silicon-Laboratories-Finland/EM358L/User-Guide-2267485-Page-19.png)
![ETRX358x-LRS and ETRX358x-LRS ©2014 Telegesis (UK) Ltd - 20 - ETRX358x-LRS Product Manual TX Current 20 Transmit current consumption at +20dBm module output power ITXVCC 140 mA 21 Transmit Current consumption at min module output power ITXVCC 52 mA Sleep Modes & Peripheral Current 22 MCU, RAM and flash, FEM, radio off 12MHz clock speed IMCU 7 mA 23 MCU, RAM and flash, FEM, radio off 24MHz clock speed IMCU 8 mA 24 Serial Controller Max data rate ISC 0.2 mA 25 Timer Max clock rate ITMR 0.25 mA 26 ADC Max sample rate IADC 1.1 mA Table 8: DC Electrical Characteristics](https://usermanual.wiki/Silicon-Laboratories-Finland/EM358L/User-Guide-2267485-Page-20.png)
![ETRX358x-LRS and ETRX358x-LRS ©2014 Telegesis (UK) Ltd - 21 - ETRX358x-LRS Product Manual 8 Digital I/O Specifications The digital I/Os of the ETRX358x-LRS module have the ratings shown below. VCC = 3.0V, TAMB = 25°C, NORMAL MODE unless otherwise stated No. Item Condition / Remark Symbol Value Unit Min Typ Max 1 Low Schmitt switching threshold Schmitt input threshold going from high to low VSWIL 0.42 x VCC 0.5 x VCC Vdc 2 High Schmitt switching threshold Schmitt input threshold going from low to high VSWIH 0.62 x VCC 0.8 x VCC MHz 3 Input current for logic 0 IIL -0.5 µA 4 Input current for logic 1 IIH 0.5 µA 5 Input Pull-up resistor value RIPU 24 29 34 kΩ 6 Input Pull-down resistor value RIPD 24 29 34 kΩ 7 Output voltage for logic 0 IOL = 4mA (8mA) for standard (high current) pads VOL 0 0.18 x VCC V 8 Output voltage for logic 1 IOH = 4mA (8mA)for standard (high current) pads VOH 0.82 x VCC VCC V 9 Output Source Current Standard current pad IOHS 4 mA 10 Output Sink current Standard current pad IOLS 4 mA 11 Output Source Current High current pad (1) IOHH 8 mA 12 Output Sink current High current pad (1) IOLH 8 mA 13 Total output current IOH + IOL 40 mA Table 9. Digital I/O Specifications No. Item Condition / Remark Symbol Value Unit Min Typ Max 1 Low Schmitt switching threshold Schmitt input threshold going from high to low VSWIL 0.42 x VCC 0.5 x VCC Vdc 2 High Schmitt switching threshold Schmitt input threshold going from low to high VSWIH 0.62 x VCC 0.68 x VCC Vdc 3 Input current for logic 0 IIL -0.5 µA 4 Input current for logic 1 IIH 0.5 µA 5 Input Pull-up resistor value Chip not reset RIPU 24 29 34 kΩ 6 Input Pull-up resistor value Chip reset RIPURESET 12 14.5 17 kΩ Table 10. nReset Pin Specifications Notes 1) High current pads are PA6, PA7, PB6, PB7, PC0](https://usermanual.wiki/Silicon-Laboratories-Finland/EM358L/User-Guide-2267485-Page-21.png)
![ETRX358x-LRS and ETRX358x-LRS ©2014 Telegesis (UK) Ltd - 22 - ETRX358x-LRS Product Manual 9 A/D Converter Characteristics The ADC is a first-order sigma-delta converter. For additional information on the ADC please refer to the EM358x datasheet. No. Item 1 A/D resolution Up to 14 bits 2 A/D sample time for 7-bit conversion 5.33µs (188kHz) 3 A/D sample time for 14-bit conversion 682µs 4 Reference Voltage 1.2V Table 11. A/D Converter Characteristics 10 AC Electrical Characteristics VCC = 3.0V, TAMB = 25°C, NORMAL MODE measured at 50Ω terminal load connected to the U.FL socket No. Receiver Value Unit Min Typ Max 1 Frequency range 2400 2500 MHz 2 Sensitivity for 1% Packet Error Rate (PER) -107 -106 -100 dBm 4 Saturation (maximum input level for correct operation) -3 2 dBm 5 High-Side Adjacent Channel Rejection (1% PER and desired signal –82dBm acc. to [1]) 41 dB 6 Low-Side Adjacent Channel Rejection (1% PER and desired signal –82dBm acc. to [1]) 40 dB 7 2nd High-Side Adjacent Channel Rejection (1% PER and desired signal –82dBm acc. to [1]) 54 dB 8 2nd Low-Side Adjacent Channel Rejection (1% PER and desired signal –82dBm acc. to [1]) 52 dB 9 Channel Rejection for all other channels (1% PER and desired signal –82dBm acc. to [1]) tbd dB 10 802.11g rejection centred at +12MHz or –13MHz (1% PER and desired signal –82dBm acc. to [1]) tbd dB 11 Co-channel rejection (1% PER and desired signal –82dBm acc. to [1]) tbd dBc 12 Relative frequency error (2x40ppm required by [1]) -120 120 ppm 13 Relative timing error (2x40ppm required by [1]) -120 120 ppm 14 Linear RSSI range 35 dB 15 Output power at highest power setting NORMAL MODE BOOST MODE 20 20 21 21 21.5 21.5 dBm 16 Output power at lowest power setting -40 dBm 17 Error vector magnitude as per IEEE802.15.4 7 15 % 18 Carrier frequency error -40 40 ppm Table 12. AC Electrical Characteristics Please Note: For the relationship between EM358x power settings and module output power please relate to chapter 10.1 of this document. When developing custom firmware the output power settings described in this document relate directly to the EM358x power settings accessible via the Ember stack API. When using the Telegesis AT Command-set firmware the settings](https://usermanual.wiki/Silicon-Laboratories-Finland/EM358L/User-Guide-2267485-Page-22.png)
![ETRX358x-LRS and ETRX358x-LRS ©2014 Telegesis (UK) Ltd - 23 - ETRX358x-LRS Product Manual mentioned in this document directly relate to the settings in the S-Register S01 which is used for setting the output power. No. Synthesiser Characteristics Limit Unit Min Typ Max 22 Frequency range 2400 2500 MHz 23 Frequency resolution 11.7 kHz 24 Lock time from off state, with correct VCO DAC settings 100 µs 25 Relock time, channel change or Rx/Tx turnaround 100 µs 26 Phase noise at 100kHz offset -71dBc/Hz 27 Phase noise at 1MHz offset -91dBc/Hz 28 Phase noise at 4MHz offset -103dBc/Hz 29 Phase noise at 10MHz offset -111dBc/Hz Table 13. Synthesiser Characteristics No. Power On Reset (POR) Specifications Limit Unit Min Typ Max 30 VCC POR release 0.62 0.95 1.2 Vdc 31 VCC POR assert 0.45 0.65 0.85 Vdc Table 14. Power On Reset Specifications No. nRESET Specifications Limit Unit Min Typ Max 32 Reset Filter Time constant 2.1 12 16 µs 33 Reset Pulse width to guarantee a reset 26 µs 34 Reset Pulse width guaranteed not to cause reset 0 1 µs Table 15. nReset Specifications](https://usermanual.wiki/Silicon-Laboratories-Finland/EM358L/User-Guide-2267485-Page-23.png)
![ETRX358x-LRS and ETRX358x-LRS ©2014 Telegesis (UK) Ltd - 24 - ETRX358x-LRS Product Manual 10.1 TX Power Characteristics The diagrams below show the typical output power and module current in dependency on EM358x-LRS power setting in NORMAL MODE at 3.6V and room temperature. Figure 3. Output Power vs. Power Setting Figure 4. Module Current vs. Power Setting](https://usermanual.wiki/Silicon-Laboratories-Finland/EM358L/User-Guide-2267485-Page-24.png)
![ETRX358x-LRS and ETRX358x-LRS ©2014 Telegesis (UK) Ltd - 25 - ETRX358x-LRS Product Manual 10.2 Power Settings for Regulatory Compliance Because of the high gain of the frontend module output power of up to 22dBm can be achieved When the antenna gain is included the output power of the EM358x transceivers needs to be reduced for regulatory compliance. The following tables list the maximum permitted power setting for the antenna types listed in Table 2. Note that this is the power out of the EM358x chip (set in register S01 when using Telegesis R3xx firmware), and the power delivered to the antenna will be higher by the gain of the RF power amplifier. (VCC = 3.0V, TAMB = 25°C, NORMAL MODE) Antenna Channels 11-24 Channel 25 Channel 26 1/2 Wave tbd tbd tbd 1/4 Wave tbd tbd tbd On Board tbd tbd tbd Table 16: Maximum Power Settings for European Compliance Finally Table 17 the maximum Power settings for FCC and IC compliance. Antenna Channels 11-24 Channel 25 Channel 26 1/2 Wave -8 -12 -43 1/4 Wave -8 -8 -26 On Board -7 -7 -26 Table 17: Maximum Power Settings for FCC, IC Compliance](https://usermanual.wiki/Silicon-Laboratories-Finland/EM358L/User-Guide-2267485-Page-25.png)
![ETRX358x-LRS and ETRX358x-LRS ©2014 Telegesis (UK) Ltd - 26 - ETRX358x-LRS Product Manual 10.3 Temperature behaviour Figure 5 and Figure 6 illustrate the temperature behaviour of the ETRX358x-LRS series of modules. Please note that although the temperature behaviour was measured to up to 100 degrees Celsius the absolute maximum rating is 85 degrees Celsius. Figure 5. Sensitivity vs. Temperature Figure 6. TX Power vs. Temperature](https://usermanual.wiki/Silicon-Laboratories-Finland/EM358L/User-Guide-2267485-Page-26.png)
![ETRX358x-LRS and ETRX358x-LRS ©2014 Telegesis (UK) Ltd - 27 - ETRX358x-LRS Product Manual 11 Physical Dimensions Figure 7. ETRX3 Physical Dimensions Symbol Explanation Distance L Length of the module 25.0mm W Width of the module 19.0mm H Height of the module 3.8mm A1 Distance centre of pad PCB edge 0.9mm A2 Pitch 1.27mm R1 Keep-out Zone from corner of PCB 17.5mm R2 Keep-out Zone from corner of PCB 4.1mm X1 Distance centre of Antenna connector PCB edge 3.8mm X2 Distance centre of Antenna connector PCB edge 2.8mm Table 18. ETRX3 Physical Dimensions For ideal RF performance when using the on-board antenna, the antenna should be located at the corner of the carrier PCB. There should be no components, tracks or copper planes in the “keep-out” area which should be as large as possible. When using the U.FL RF connector the “keep-out” area does not have to be kept. NB: The modules’ transmit/receive range will depend on the antenna used and also the housing of the finished product.](https://usermanual.wiki/Silicon-Laboratories-Finland/EM358L/User-Guide-2267485-Page-27.png)
![ETRX358x-LRS and ETRX358x-LRS ©2014 Telegesis (UK) Ltd - 28 - ETRX358x-LRS Product Manual 12 Recommended Reflow Profile Recommended temperature profile for reflow soldering Temp.[°C] Time [s] 230°C -250°C max. 220°C 150°C – 200°C 90 ±30s 60 +60s-20s Figure 8. Recommended Reflow Profile Use of “No-Clean” solder paste is recommended to avoid the requirement for a cleaning process. Cleaning the module is strongly discouraged because it will be difficult to ensure no cleaning agent and other residuals are remaining underneath the shielding can as well as in the gap between the module and the host board. Please Note: Maximum number of reflow cycles: 2 Opposite-side reflow is prohibited due to the module’s weight. (i.e. you must not place the module on the bottom / underside of your PCB and re-flow).](https://usermanual.wiki/Silicon-Laboratories-Finland/EM358L/User-Guide-2267485-Page-28.png)
![ETRX358x-LRS and ETRX358x-LRS ©2014 Telegesis (UK) Ltd - 29 - ETRX358x-LRS Product Manual 13 Product Label Drawing Figure 9. Product Label The label dimensions are 16mm x 14 mm. The label will withstand temperatures used during reflow soldering. The characters “HR” are only present on the versions with the Hirose connector, Imprint Description ETRX3587HR-LRS Module Order code Possible codes are: - ETRX3581-LRS - ETRX3581HR-LRS - ETRX3582-LRS - ETRX3582HR-LRS - ETRX3585-LRS - ETRX3585HR-LRS - ETRX3586-LRS - ETRX3586HR-LRS - ETRX3587-LRS - ETRX3587HR-LRS - ETRX3588-LRS - ETRX3588HR-LRS 000001 Indication for the serial number. 090101 Production Date Code in the format YYMMDD, e.g. 090602 01 Indication for factory ID 02 Indication for the hardware revision FCC ID: S4GEM358L FCC ID code for this product IC: 8735A-EM358L The IC ID CE The CE Mark 2D-Barcode Information in the 2D-Barcode are the serial number [6 characters], the Part-Order code, identifier for the batch number [2 characters], the identifier for the hardware release [2 characters] and the production date code in the format Year-Month-Day [6 characters], all separated by a semicolon. Table 19. ETRX358x-LRS Label Details](https://usermanual.wiki/Silicon-Laboratories-Finland/EM358L/User-Guide-2267485-Page-29.png)
![ETRX358x-LRS and ETRX358x-LRS ©2014 Telegesis (UK) Ltd - 30 - ETRX358x-LRS Product Manual 14 Recommended Footprint In order to surface mount an ETRX3 series module, we recommend that you use pads which are 1mm wide and 1.2mm high. Unless using the “HR” variants the “keep-out” zone shown in section 11 must be retained, and it must be ensured that this area is free of copper tracks and/or copper planes/layers. You must also ensure that there is no exposed copper on your layout which may contact with the underside of the ETRX3 series module. For best RF performance it is required to provide good ground connections to the ground pads of the module. It is recommended to use multiple vias between each ground pad and a solid ground plane to minimize inductivity in the ground path. Figure 10. Recommended Footprint The land pattern dimensions above serve as a guideline. We recommend that you use the same pad dimensions for the solder paste screen as you have for the copper pads. However these sizes and shapes may need to be varied depending on your soldering processes and your individual production standards. We recommend a paste screen thickness of 120µm to 150µm. Figure 11 shows the typical pad dimensions of the module and Figure 12-Figure 14 in section 14.1 show examples of how to align the module on its host PCB.](https://usermanual.wiki/Silicon-Laboratories-Finland/EM358L/User-Guide-2267485-Page-30.png)
![ETRX358x-LRS and ETRX358x-LRS ©2014 Telegesis (UK) Ltd - 31 - ETRX358x-LRS Product Manual Although the undersides of the ETRX3 series modules are fully coated, no exposed copper, such as through-hole vias, planes or tracks on your board component layer, should be located below the ETRX3 series module in order to avoid ‘shorts’. All ETRX3 series modules use a multilayer PCB containing an inner RF shielding ground plane, therefore there is no need to have an additional copper plane directly under the ETRX3 series module. Figure 11. Typical pad dimensions Finally it is recommended to use no clean flux when soldering the ETRX358x family of modules and to not use a washing process after reflow. If the process does require washing then care must be taken that no washing agent is trapped underneath the shielding can after the drying process has completed.](https://usermanual.wiki/Silicon-Laboratories-Finland/EM358L/User-Guide-2267485-Page-31.png)
![ETRX358x-LRS and ETRX358x-LRS ©2014 Telegesis (UK) Ltd - 32 - ETRX358x-LRS Product Manual 14.1 Recommended Placement When placing the module please either locate the antenna in the corner as shown in Figure 12 so that the recommended antenna keepout zone is being followed, or add a no copper zone as indicated in Figure 14. Figure 12. Typical placement Figure 13. How to not place the Module](https://usermanual.wiki/Silicon-Laboratories-Finland/EM358L/User-Guide-2267485-Page-32.png)
![ETRX358x-LRS and ETRX358x-LRS ©2014 Telegesis (UK) Ltd - 33 - ETRX358x-LRS Product Manual Figure 14. Adding a no copper / no component area](https://usermanual.wiki/Silicon-Laboratories-Finland/EM358L/User-Guide-2267485-Page-33.png)
![ETRX358x-LRS and ETRX358x-LRS ©2014 Telegesis (UK) Ltd - 34 - ETRX358x-LRS Product Manual 14.2 Example carrier board Since the RF performance of the module with the on board antenna is strongly dependent on the proper location of the module on its carrier board figure 17 shows the reference carrier board which was used during testing by Telegesis. Figure 17: Reference Board For best performance it is recommended to locate the antenna towards the corner of the carrier board and to respect the recommended keep-out areas as described in section 11. Finally to provide a good reference ground to the on board antenna, the carrier board should have a ground plane spanning no less than 40 x 40mm. In many cases a smaller ground plane will suffice, but a degradation in radio performance could be the result.](https://usermanual.wiki/Silicon-Laboratories-Finland/EM358L/User-Guide-2267485-Page-34.png)
![ETRX358x-LRS and ETRX358x-LRS ©2014 Telegesis (UK) Ltd - 35 - ETRX358x-LRS Product Manual 15 Reliability Tests The following measurements will be conducted after the module has been exposed to standard room temperature and humidity for 1 hour. No Item Limit Condition 1 Vibration test Electrical parameter should be in specification Freq.:40Hz,Amplitude:1.5mm 20min. / cycle,1hrs. each of X and Y axis 2 Shock test the same as the above Dropped onto hard wood from height of 50cm for 10 times 3 Heat cycle test the same as the above -40°C for 30min. and +85°C for 30min.; each temperature 300 cycles 5 Low temp. test the same as the above -40°C, 300h 6 High temp. test the same as the above +85°C, 300h Table 20: Reliability Tests 16 Application Notes 16.1 Safety Precautions These specifications are intended to preserve the quality assurance of products as individual components. Before use, check and evaluate their operation when mounted on your products. Abide by these specifications when using the products. These products may short-circuit. If electrical shocks, smoke, fire, and/or accidents involving human life are anticipated when a short circuit occurs, then provide the following failsafe functions as a minimum: (1) Ensure the safety of the whole system by installing a protection circuit and a protection device. (2) Ensure the safety of the whole system by installing a redundant circuit or another system to prevent a single fault causing an unsafe status. 16.2 Design Engineering Notes (1) Heat is the major cause of shortening the life of these products. Avoid assembly and use of the target equipment in conditions where the product’s temperature may exceed the maximum allowable. (2) Failure to do so may result in degrading of the product’s functions and damage to the product. (3) If pulses or other transient loads (a large load applied in a short time) are applied to the products, before use, check and evaluate their operation when assembled onto your products. (4) These products are not intended for other uses, other than under the special conditions shown below. Before using these products under such special conditions, check their performance and reliability under the said special conditions carefully, to determine whether or not they can be used in such a manner.](https://usermanual.wiki/Silicon-Laboratories-Finland/EM358L/User-Guide-2267485-Page-35.png)
![ETRX358x-LRS and ETRX358x-LRS ©2014 Telegesis (UK) Ltd - 36 - ETRX358x-LRS Product Manual (5) In liquid, such as water, salt water, oil, alkali, or organic solvent, or in places where liquid may splash. (6) In direct sunlight, outdoors, or in a dusty environment (7) In an environment where condensation occurs. (8) In an environment with a high concentration of harmful gas (e.g. salty air, HCl, Cl2, SO2, H2S, NH3, and NOx) (9) If an abnormal voltage is applied due to a problem occurring in other components or circuits, replace these products with new products because they may not be able to provide normal performance even if their electronic characteristics and appearances appear satisfactory. (10) Mechanical stress during assembly of the board and operation has to be avoided. (11) Pressing on parts of the metal cover or fastening objects to the metal cover is not permitted. 16.3 Storage Conditions (1) The module must not be stressed mechanically during storage. (2) Do not store these products in the following conditions or the performance characteristics of the product, such as RF performance, may well be adversely affected: (3) Storage in salty air or in an environment with a high concentration of corrosive gas, such as Cl2, H2S, NH3, SO2, or NOX (4) Storage (before assembly of the end product) of the modules for more than one year after the date of delivery at your company even if all the above conditions (1) to (3) have been met, should be avoided.](https://usermanual.wiki/Silicon-Laboratories-Finland/EM358L/User-Guide-2267485-Page-36.png)
![ETRX358x-LRS and ETRX358x-LRS ©2014 Telegesis (UK) Ltd - 37 - ETRX358x-LRS Product Manual 17 Packaging 17.1 Embossed Tape (1) Dimension of the tape (2) Cover tape peel force Force direction Speed = 300mm/min. Cover tape peel force =0.098~0.68N (10~70g) θ= 10deg (3) Empty pockets NB: Empty pockets in the component packed area will be less than two per reel and those empty pockets will not be consecutive. Empty pockets more Components Empty pockets Top cover tape Direction of feed g](https://usermanual.wiki/Silicon-Laboratories-Finland/EM358L/User-Guide-2267485-Page-37.png)
![ETRX358x-LRS and ETRX358x-LRS ©2014 Telegesis (UK) Ltd - 38 - ETRX358x-LRS Product Manual 17.2 Component Orientation Top cover tape will not obstruct the carrier tape holes and will not extend beyond the edges of the carrier tape (top view) Component Orientation Part No. Direction 17.3 Reel Dimensions (4) Quantity per reel: 600 pieces (5) Marking: Part No. / Quantity / Lot No. and manufacturer part# with bar-code will be on the reel](https://usermanual.wiki/Silicon-Laboratories-Finland/EM358L/User-Guide-2267485-Page-38.png)
![ETRX358x-LRS and ETRX358x-LRS ©2014 Telegesis (UK) Ltd - 39 - ETRX358x-LRS Product Manual 17.4 Packaging (6) Each reel will be packed in a hermetically-sealed bag (7) Marking: Reel / Antistatic Packaging / Reel Box and outer Box will carry the following label Imprint Description MFG P/N: 99X902DL Internal use Lot: 00 Internal use P/N:ETRX3587-LRS Telegesis Module Order Code. Quantity:600 Quantity of modules inside the reel/carton Reel No: 000001 Six digit unique Reel number counting up from 000001 Date:120824 Date Code in the format YYMMDD, e.g. 120824 P/C: ETRX3587-LRS-R308 Module product code with reference to firmware/module type selected during ATE. If needed multiline. 2D-Barcode Information in the 32x32 Datamatrix 2D-Barcode are and identifier “!REEL” [5 characters], the reel number [6 characters], the Module Order code [max 18 characters ], the quantity [max 4 characters] , the date code in the format Year-Month-Day [6 characters] and the product code [max 40 characters] , all separated by a semicolon.](https://usermanual.wiki/Silicon-Laboratories-Finland/EM358L/User-Guide-2267485-Page-39.png)
![ETRX358x-LRS and ETRX358x-LRS ©2014 Telegesis (UK) Ltd - 40 - ETRX358x-LRS Product Manual 18 Ordering Information 2 MOQ and Lead Time applies. Only stocked modules are ETRX3587 and ETRX3587HR Ordering/Product Code Description ETRX3581-LRS2 ETRX3582-LRS2 ETRX3585-LRS2 ETRX3586-LRS2 ETRX3587-LRS ETRX3588-LRS2 Power amplified Telegesis Wireless Mesh Networking Module with Silicon Labs ZigBee Technology: • Based on Silicon Labs EM358x SoC • Telegesis AT Style Command Interpreter based on • EmberZNet meshing and self-healing ZigBee PRO stack • Integrated 2.4GHz Antenna ETRX3581HR-LRS2 ETRX3582HR-LRS2 ETRX3585HR-LRS2 ETRX3586HR-LRS2 ETRX3587HR-LRS ETRX3588HR-LRS2 Power amplified Telegesis Wireless Mesh Networking Module with Silicon Labs ZigBee Technology: • Based on Silicon Labs EM358x SoC • Telegesis AT Style Command Interpreter based on • EmberZNet meshing and self-healing ZigBee PRO stack • U.FL coaxial Antenna Connector ETRX357DVK Telegesis Development Kit with: • 3 x ETRX3DVK Development Boards • 3 x USB cables • 2 x ETRX357 on carrier boards • 2 x ETRX357HR on carrier boards • 2 x ETRX357-LRS on carrier boards • 2 x ETRX357HR-LRS on carrier boards • 1 x ETRX3USB USB stick • 2 x ½-wave antennae • 2 x ¼-wave antennae ETRX3587 Expansion Pack • 2 x ETRX3587 on carrier boards • 2 x ETRX3587HR on carrier boards • 2 x ETRX3587-LRS on carrier boards • 2 x ETRX3587HR-LRS on carrier boards Notes: • Customers’ PO’s must state the Ordering/Product Code. • There is no “blank” version of the ETRX358x modules available. All Modules are pre-programmed with the Telegesis AT style command interpreter based on the EmberZNet stack. (In case it is desired to program custom firmware the pre-programmed firmware can simply be overwritten).](https://usermanual.wiki/Silicon-Laboratories-Finland/EM358L/User-Guide-2267485-Page-40.png)
![ETRX358x-LRS and ETRX358x-LRS ©2014 Telegesis (UK) Ltd - 41 - ETRX358x-LRS Product Manual 19 Trademarks All trademarks, registered trademarks and products names are the sole property of their respective owners. 20 Disclaimer Product and company names and logos referenced may either be trademarks or registered trademarks of their respective companies. We reserve the right to make modifications and/or improvements without prior notification. All information is correct at time of issue. Telegesis (UK) Ltd does not convey any license under its patent rights or assume any responsibility for the use of the described product 21 RoHS Declaration Declaration of environmental compatibility for supplied products: Hereby we declare to our best present knowledge based on the declaration of our suppliers that this product does not contain any of the substances which are banned by Directive 2011/65/EU (RoHS) 22 Data Sheet Status Telegesis (UK) Ltd. reserves the right to change the specification without notice, in order to improve the design and supply the best possible product. Please consult the most recently issued data sheet before initiating or completing a design. 23 Life Support Policy This product is not designed for use in life support appliances, devices, or systems where malfunction can reasonably be expected to result in a significant personal injury to the user, or as a critical component in any life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. Customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Telegesis (UK) Ltd. for any damages resulting.](https://usermanual.wiki/Silicon-Laboratories-Finland/EM358L/User-Guide-2267485-Page-41.png)
![ETRX358x-LRS and ETRX358x-LRS ©2014 Telegesis (UK) Ltd - 42 - ETRX358x-LRS Product Manual 24 Related Documents [1] IEEE Standard 802.15.4 –2003 Wireless Medium Access Control (MAC) and Physical Layer (PHY) Specifications for Low-Rate Wireless Personal Area Networks (LR-WPANs) [2] Datasheet EM35x, Ember. (www.ember.com) [3] Datasheet U.FL-Series 2004.2 Hirose Ultra Small Surface Mount Coaxial Connectors - Low Profile 1.9mm or 2.4mm Mated Height [4] The ZigBee specification (www.zigbee.org) [5] Specification for Antenova Rufa Antenna (www.antenova.com) [6] Embedded Antenna design Ltd. (EAD Ltd.) (www.ead-ltd.com) 25 Contact Information Website: www.telegesis.com E-mail sales@telegesis.com Telegesis (UK) Limited Abbey Barn Business Centre Abbey Barn Lane High Wycombe Bucks HP10 9QQ UK Tel: +44 (0)1494 510199 Fax: +44 (0)5603 436999](https://usermanual.wiki/Silicon-Laboratories-Finland/EM358L/User-Guide-2267485-Page-42.png)