Simcom 2013060302 GSM/GPRS/EDGE/UMTS/HSDPA Terminal User Manual unser manual

Shanghai Simcom Ltd. GSM/GPRS/EDGE/UMTS/HSDPA Terminal unser manual

Contents

unser manual

Download: Simcom 2013060302 GSM/GPRS/EDGE/UMTS/HSDPA Terminal User Manual unser manual
Mirror Download [FCC.gov]Simcom 2013060302 GSM/GPRS/EDGE/UMTS/HSDPA Terminal User Manual unser manual
Document ID1998776
Application IDe+Oy40qfzQuzK3hkL72FUg==
Document Descriptionunser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize257.6kB (3220022 bits)
Date Submitted2013-06-24 00:00:00
Date Available2013-06-24 00:00:00
Creation Date2013-04-16 14:05:55
Producing SoftwareAcrobat Distiller 8.0.0 (Windows)
Document Lastmod2013-06-08 09:49:31
Document Titleunser manual
Document CreatorAcrobat PDFMaker 8.0 for Word
Document Author: cheng.shi

T5320_User Guide_V1.04
Smart Machine Smart Decision
Document Title
T5320 User Guide
Version
1.04
Date
2013-04-15
Status
Release
Document Control ID
T5320 User Guide V1.04
General Notes
SIMCom offers this information as a service to its customers, to support application and engineering efforts that
use the products designed by SIMCom. The information provided is based upon requirements specifically
provided to SIMCom by the customers. SIMCom has not undertaken any independent search for additional
relevant information, including any information that may be in the customer’s possession. Furthermore, system
validation of this product designed by SIMCom within a larger electronic system remains the responsibility of the
customer or the customer’s system integrator. All specifications supplied herein are subject to change.
Copyright
This document contains proprietary technical information which is the property of SIMCom Limited, copying of
this document and giving it to others and the using or communication of the contents thereof, are forbidden
without express authority. Offenders are liable to the payment of damages. All rights reserved in the event of grant
of a patent or the registration of a utility model or design. All specification supplied herein are subject to change
without notice at any time.
This device complies with part 15B of the FCC rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference
(2) this device must accept any interference, including interference that may cause undesired operation.”
WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance
could void the user's authorityto operate the equipment.
Copyright © Shanghai SIMCom Wireless Solutions Ltd. 2013
T5320_User Guide_V1.04
2013- 04-15
Smart Machine Smart Decision
Contents
Contents.................................................................................................................................................................... 3
Version History ........................................................................................................................................................ 6
Introduction....................................................................................................................................................... 7
Key features....................................................................................................................................................... 8
Terminal dimensions ........................................................................................................................................ 9
Installation....................................................................................................................................................... 10
Interface introduction......................................................................................................................................11
5.1
Overview .................................................................................................................................................11
5.2
T5320 Functional Diagram..................................................................................................................... 12
5.3
Accessory information............................................................................................................................ 13
Application Interface...................................................................................................................................... 14
6.1
Power Supply.......................................................................................................................................... 14
6.2
Serial Interface........................................................................................................................................ 15
6.3
10 PIN I/O interface ............................................................................................................................... 16
6.3.1 Audio interface.................................................................................................................................... 18
6.3.2 ADC channel....................................................................................................................................... 19
6.3.3 GPIO interfaces................................................................................................................................... 20
6.4
LED indicator ......................................................................................................................................... 21
6.5
Micro USB interface............................................................................................................................... 22
6.6
USIM Card Interface .............................................................................................................................. 23
6.7
Antenna interface.................................................................................................................................... 24
6.7.1 Antenna connector .............................................................................................................................. 24
6.7.2 Antenna type ....................................................................................................................................... 24
6.7.3 Antenna placement.............................................................................................................................. 24
Electrical, Reliability and Radio Characteristics......................................................................................... 25
7.1
Absolute Maximum Ratings................................................................................................................... 25
7.2
Recommended Operating Conditions..................................................................................................... 25
7.3
Electro-Static Discharge ......................................................................................................................... 25
7.4
Operating frequency ............................................................................................................................... 26
7.5
Transmitter output power and receiver sensitivity ................................................................................. 26
Software/ Firmware Upgrade ........................................................................................................................ 27
8.1
Tool introduction .................................................................................................................................... 27
8.2
Illustration of software updating............................................................................................................. 27
Appendix ................................................................................................................................................................ 30
A. Related Documents.......................................................................................................................................... 30
B. Terms and Abbreviations ................................................................................................................................. 31
C. Safety Caution ................................................................................................................................................. 32
T5320_User Guide_V1.04
2013- 04-15
Smart Machine Smart Decision
Table Index
TABLE 1: T5320 SERIES FREQUENCY BANDS........................................................................................................... 7
TABLE 2: T5320 KEY FEATURES................................................................................................................................... 8
TABLE 3: THE POWER LINE ASSIGNMENT.............................................................................................................. 14
TABLE 4: 9-POLE D-SUB (FEMALE) RS-232.............................................................................................................. 15
TABLE 5: SIGNAL ASSIGNMENT OF 10 PIN CABLE ............................................................................................... 17
TABLE 6: MIC INPUT CHARACTERISTICS ............................................................................................................... 18
TABLE 7: SPEAKER OUTPUT CHARACTERISTICS ................................................................................................. 18
TABLE 8: AUDIO PARAMETER ................................................................................................................................... 18
TABLE 9: ADC SPECIFICATION .................................................................................................................................. 19
TABLE 10: AT+CADC READ ADC................................................................................................................................ 20
TABLE 11: T5320 GPIOS................................................................................................................................................ 21
TABLE 12: STATUS OF THE NETLIGHT INDICATOR (GREEN).............................................................................. 21
TABLE 13: AT+CUSBSPD SWITCH T5320 USB HIGH OR FULL SPEED.............................................................. 22
TABLE 14: ANTENNA CHOOSING CONSIDERATION.............................................................................................. 24
TABLE 15: ABSOLUTE MAXIMUM RATINGS........................................................................................................... 25
TABLE 16: RECOMMENDED OPERATING CONDITIONS ....................................................................................... 25
TABLE 17: THE ESD CHARACTERISTICS (TEMPERATURE: 25℃, HUMIDITY: 45 %) ....................................... 26
TABLE 18: OPERATING FREQUENCY........................................................................................................................ 26
TABLE 19: TRANSMITTER OUTPUT POWER AND RECEIVER SENSITIVITY .................................................... 26
TABLE 20: RELATED DOCUMENTS ........................................................................................................................... 30
TABLE 21: TERMS AND ABBREVIATIONS................................................................................................................ 31
TABLE 22: SAFETY CAUTION..................................................................................................................................... 32
T5320_User Guide_V1.04
2013- 04-15
Smart Machine Smart Decision
Figure Index
FIGURE 1: T5320 OVERVIEW ........................................................................................................................................ 7
FIGURE 2: MECHANICAL DIMENSIONS OF T5320(UNIT: MM) ....................................................................... 10
FIGURE 3: INSTALLATION OF THE TERMINAL ...................................................................................................... 11
FIGURE 4: T5320 INTERFACE FRONT VIEW............................................................................................................. 12
FIGURE 5: T5320 INTERFACE BACK VIEW............................................................................................................... 12
FIGURE 6: T5320 FUNCTIONAL DIAGRAM .............................................................................................................. 13
FIGURE 7: ACCESSORY INFORMATION.................................................................................................................... 13
FIGURE 8: DIMENSIONS OF POWER LINE(UNIT: MM)..................................................................................... 14
FIGURE 9: POWER INTERFACE .................................................................................................................................. 15
FIGURE 10: PIN ASSIGNMENT RS-232 (D-SUB 9-POLE FEMALE) ........................................................................ 15
FIGURE 11: COM PORT PROPERTIES OF THE HYPER TERMINAL....................................................................... 16
FIGURE 12: SIGNAL ASSIGNMENT OF 10PIN I/O PORT ......................................................................................... 17
FIGURE 13: DIMENSIONS OF 10-LINE CABLE......................................................................................................... 17
FIGURE 14: SPEAKER REFERENCE CIRCUIT .......................................................................................................... 18
FIGURE 15: INDICATOR LED....................................................................................................................................... 21
FIGURE 16: MICRO USB INTERFACE ........................................................................................................................ 22
FIGURE 17: INSTALLATION OF SIM CARD .............................................................................................................. 23
FIGURE 18: ANTENNA INTERFACE ........................................................................................................................... 24
FIGURE 19: VIRTUAL PORTS IN COMPUTER MANAGER WINDOW ........................................................................ 27
FIGURE 20: QDL WINDOW .......................................................................................................................................... 27
FIGURE 21: BROWSE THE SOURCE FILE ................................................................................................................. 28
FIGURE 22: CLICK DOWNLOAD BUTTON WITHOUT POWER UP ....................................................................... 28
FIGURE 23: UPGRADE IN PROCEEDING................................................................................................................... 29
FIGURE 24: FINISH UPGRADING ............................................................................................................................... 29
T5320_User Guide_V1.04
2013- 04-15
Smart Machine Smart Decision
Version History
Date
Version
Description of change
Author
2012-07-23
1.01
Origin
Libing
2012-08-10
1.02
Figure 7 & Figure 11 are replaced to new pictures.
Libing
2012-10-08
1.03
Modify T5320 GPIO example 1.
Libing
2013-04-15
1.04
Add description of RF bands and frequencies.
Libing
T5320_User Guide_V1.04
2013. 04. 15
Smart Machine Smart Decision
Introduction
This document describes features, functions and interfaces of T5320 terminal in great detail.
T5320 is a quad-band GSM/GPRS/EDGE and dual-band UMTS /HSDPA that works on frequencies of GSM
850MHz, EGSM 900 MHz, DCS 1800 MHz, PCS 1900MHz and WCDMA 2100/900MHz, 2100/850 MHz or
1900/850MHz, which is a ideal solution for wireless m2m applications, the terminal features HSDPA Category
5/6 -3.6 Mbps.
With the help of this document user can understand T5320 interface specifications, electrical and mechanical
quickly.
Table 1: T5320 series frequency bands
Standard
GSM
Frequency
T5320E
T5320J
T5320A
GSM 850MHz
EGSM 900MHz
DCS1800MHz
PCS1900MHz
WCDMA 850MHz
WCDMA
HSPA
WCDMA 900MHz
WCDMA 1900MHz
WCDMA 2100MHz
HSDPA
HSUPA
Figure 1: T5320 overview
T5320_User Guide_V1.04
2013- 04-15
Smart Machine Smart Decision
Key features
T5320 terminal terminal has the following features:
1. Standard AT commands set
2. SIMCom proprietary AT commands set
3. watch-dog function
4. Short circuit protection
5. Voice call
6. GPIOs
7. ADC function
Table 2: T5320 key features
Feature
Implementation
Power supply
5V ~ 30V
●
●
Transmission data
●
●
●
●
Dual-mode UMTS/HSDPA/EDGE/GPRS operation
GPRS Class B, multislot class 12 operation, Supports coding scheme: CS1-4
EDGE multislot class 12 operation, Supports coding schemes MSC1-9
UMTS R99 data rates-384 kbps DL/UL
HSDPA Category 5/6 -3.6 Mbps and Category12-1.8 Mbps
Integrate the TCP/IP protocol
Transmitting power
Class 4 (+33dBm) for GSM850 and EGSM900
Class 1 (+30dBm) for DCS 1800 PCS GSM1900
Class 3 (+24dBm) for WCDMA 2100, WCDMA FDD BDI
Class 3 (+24dBm) for WCDMA 1900, WCDMA FDD BDII
Class 3 (+24dBm) for WCDMA 900, WCDMA FDD BDVIII
Class 3 (+24dBm) for WCDMA 850, WCDMA FDD BDV
Temperature range
Normal operation: -30°C ~ +75°C
Restricted operation: -35°C ~ -30°C and +75 °C ~ +80°C*
Storage temperature -40°C ~ +85°C
CSD
CSD feature: 9.6, 14.4, 64 kbps UL/DL
SMS
MT, MO, CB, Text and PDU mode
● SMS storage: SIM card
● Support transmission of SMS alternatively over CSD or GPRS.
choose preferred mode.
FAX
Group 3 Class 1
USIM interface
Support USIM card: 1.8V, 3V
External antenna
SMA type RF connector
Audio features
Speech codec modes:
● Half Rate (ETS 06.20)
● Full Rate (ETS 06.10)
● Enhanced Full Rate (ETS 06.50 / 06.60 / 06.80)
● AMR (WCDMA)
● AMR+QCP (GSM)
●
T5320_User Guide_V1.04
User can
2013- 04-15
Smart Machine Smart Decision
●
USB
Support USB2.0 Slave mode
A5/1, A5/2, and A5/3 ciphering
Serial port:
Full modem interface with status and control lines, unbalanced,
asynchronous.
1200bps to 115200bps.
Default rate is 115200bps.
Can be used for AT commands data stream.
Support RTS/CTS hardware handshake and software ON/OFF flow control.
Multiplex ability according to GSM 07.10 Multiplexer Protocol.
RS232 serial port
Phonebook management
Support phonebook types: SM, FD, LD, RC, ON, MC.
SIM application toolkit
Support SAT class 3, GSM 11.14 Release 98
Support USAT
Physical characteristics
Size: 98*60*23mm
Weight: 128g
Firmware upgrade
Firmware upgradeable by USB interface
T5320 does work at this temperature, but some radio frequency characteristics may deviate from the GSM specification.
Terminal dimensions
T5320_User Guide_V1.04
2013- 04-15
Smart Machine Smart Decision
Figure 2: Mechanical dimensions of T5320(Unit: mm)
Installation
The terminal can be fixed by two kickstands (Optional) that provided by SIMCom, the following figure is the
illustration.
T5320_User Guide_V1.04
10
2013- 04-15
Smart Machine Smart Decision
Figure 3: Installation of the terminal
5.1
Interface introduction
Overview
T5320 Terminal provides the following connectors for power supply, GPIOs, Audio, ADC, Serial port and
antenna:
z The GSM/WCDMA antenna interface(SMA type female connector)
z The 4 PIN I/O port for power supply
z The 10 PIN I/O port for audio, GPIOs and ADC
z The standard RS232 interface
z LED indicator for power (Red) and GSM/WCDMA netlight (Green)
z USIM card holder
z Micro USB interface
T5320_User Guide_V1.04
11
2013- 04-15
Smart Machine Smart Decision
Figure 4: T5320 interface Front view
Figure 5: T5320 interface Back view
Note: For the I/O interface, SIMCom provides 4-line cable and 10-line cable (optional) to assist developers, it
will be introduced at the following chapter.
5.2
T5320 Functional Diagram
The following figure shows a functional diagram of T5320 and typical accessories.
T5320_User Guide_V1.04
12
2013- 04-15
Smart Machine Smart Decision
Figure 6: T5320 functional diagram
5.3
Accessory information
Figure 7: Accessory information
T5320_User Guide_V1.04
13
2013- 04-15
Smart Machine Smart Decision
A: T5320 Terminal
B: GSM Antenna
C: Male to Female DB9 Line
D: 5V Adapter
E: Two kickstands (Optional)
F: 10-Line cable (Optional)
G: Micro-USB cable
6.1
Application Interface
Power Supply
Customer can use the DC adapter that SIMCom provides as the power source.
If customer does not use the adapter, then DC source should be satisfied with the following requirements.
z Input voltage range 5-30V
z Normal voltage
12V
z Current ability
1A
The following chapter introduces the power line that SIMCom provides to customers, customer can power the
terminal by connect the terminal to the DC source via this line.
The power line includes four lines as the following figure shows, and table 2 gives a detailed description.
NOTE:The part number of power line connector is ATOM GROUP LIMITED ATOM010070190003 in T5320
side. User can login http://www.asia-atom.com/en/ for more information.
Table 3: The power line assignment
PIN Number
Colour
Item
white
NC
Red
Power
Yellow
NC
Black
Ground
Figure 8: dimensions of power line(Unit: mm)
T5320_User Guide_V1.04
14
2013- 04-15
Smart Machine Smart Decision
Figure 9: Power interface
When a valid power appears the terminal will power up automatic, for the MCU that inside the terminal processed
the power up part, MCU also acts as a Watch Dog, when the terminal runs wrong, MCU will cut off the power
and recover it immediately to restart the terminal.
6.2
Serial Interface
T5320 provides one asynchronous RS232 serial port (female).The RS232 standard interface serves to connect a
PC, Data Terminal Equipment (DTE) or other application, which acts as host controller of the T5320 Terminal
with all its functions. Through the RS232 interface it can be used as GSM/GPRS modem for sending and
receiving of SMS, Data and Fax calls.
Figure 10: Pin assignment RS-232 (D-Sub 9-pole female)
Table 4: 9-pole D-Sub (female) RS-232
Pin no
Signal name
I/O
Function
DCD
Data Carrier Detected
RXD
Receive Data
T5320_User Guide_V1.04
15
2013- 04-15
Smart Machine Smart Decision
TXD
Transmit Data
DTR
Data Terminal Ready
Attention: The ignition of T5320
Terminal is activated via a rising
edge of high potential (+3 ... +15 V)
GND
Ground
DSR
Data Set Ready
RTS
Request To Send
CTS
Clear To Send
RING
Ring Indication
Note: User can use AT command “AT+IPR=x” to set a fixed baud rate and the setting will be saved to
non-volatile flash memory automatically. After the configuration is set as fixed baud rate, the URC such as
"RDY", "+CFUN: 1" and "+CPIN: READY” will be reported when T5320 is powered on.
Hyper terminal usually as the PC software tool to operate T5320; customer can set up a connection between PC
and terminal, configure the port properties as the figure 9 shows.
Figure 11: COM port properties of the hyper terminal
6.3
10 PIN I/O interface
T5320 provides a 10 PIN I/O interface for customer use, including Audio, GPIOs and 1 ADC channel.
The following figure gives a brief view of signal assignment.
T5320_User Guide_V1.04
16
2013- 04-15
Smart Machine Smart Decision
Figure 12: signal assignment of 10PIN I/O port
NOTE:The part number of the 10 PIN I/O connector is ATOM GROUP LIMITED ATOM010070190005 in
T5320 side. User can login http://www.asia-atom.com/en/ for more information.
To make the usage conveniently, SIMCom provides a cable for customer, it can be inserted to the 10 PIN I/O port
so customer can develop their application by connecting some devices.
Figure 11 shows the specification of cable.
Figure 13: Dimensions of 10-line cable
Table 5: signal assignment of 10 pin cable
Connecting diagram
P1
Wire color and cutting
length
Terminal signal
Signal name
I/O
Command
Configurable
by AT
commands
Green
GPIO3
I/O
Yellow
GPIO1
I/O
T5320_User Guide_V1.04
17
2013- 04-15
Smart Machine Smart Decision
6.3.1
Black
Orange
Brown
GND
Ground
SPK+
MIC+
White
GPIO4
I/O
Gray
GPIO2
I/O
Red
ADC
Purple
SPK-
10
Blue
MIC-
1007 26#
Configurable
by AT
commands
Audio interface
T5320 has one pair of audio input and audio output; it can be connected to a speakerphone directly.
Figure 14: Speaker reference circuit
Firstly, customer must use the “AT +CSDVC=3” to select speaker audio channel.
Customer can set the terminal MIC gain level to make the sounds louder so that the listener can hear more clearly.
And if the sound a little lower on the terminal side, customer can use the “AT +CLVL” to make the sound higher
so that customer can hear clearly.
The AT commands should be send to the terminal by RS232 or USB interface, and the following table shows the
detail commands.
Table 6: MIC input characteristics
Parameter
Working Voltage
Min
Typ
1.8
Max
Unit
Working Current
External Microphone Load Resistance
0.07
1.2
0.4
2.2
mA
k Ohms
Table 7: Speaker output characteristics
Parameter
Quiescent Current
Load resistance
Output power(1KHz)
Min
Typ
2.5
500
Max
Unit
mA
Ohm
mW
Table 8: Audio parameter
T5320_User Guide_V1.04
18
2013- 04-15
Smart Machine Smart Decision
Parameter
Influence to
Range
Gain range
Calculation
AT command
micAmp1
MICP/MICN
analogue amplifier
gain before ADC
0…1
0…24dB
2 steps
AT+CMICAMP1
txVol
Digital gain of input
signal after ADC
0,
1...65535
Mute,
-84...+12dB
20 * log
(txVol/
16384)
AT+CTXVOL
txGain
Digital gain of input
signal
after
summation
of
sidetone
0,
1...65535
Mute,
-84...+12dB
20 * log
(txGain/
16384)
AT+CTXGAIN
txFilter
Input PCM 13-tap
filter parameters, 7
values
0...65535
---
MATLAB
calculate
AT+CTXFTR
rxGain
Digital
gain
of
output signal after
summation
of
sidetone
0,
1...65535
Mute,
-84...+12dB
20 * log
(rxGain/
16384)
AT+CRXGAIN
rxVol
Digital Volume of
output signal after
speech
decoder,
before summation of
sidetone and DAC
-300…300
dbm
-300…300d
bm
AT+CLVL
AT+CVLVL
AT+CRXVOL
stGain
Digital attenuation
of sidetone
0, 1...65535
Mute,
-96...0dB
20 * log
(stGain/
16384) -12
AT+SIDET
rxFilter
Output PCM 13-tap
filter parameters, 7
values
0...65535
---
MATLAB
calculate
AT+CRXFTR
Please refer to document [1] and document [3] for details.
6.3.2
ADC channel
T5320 provides an auxiliary ADC, which can be used to measure the voltage. User can use AT command
“AT+CADC=2” to read the voltage value.
Table 9: ADC specification
Parameter
Min
Typ
Max
Unit
Voltage range
2.2
ADC Resolution
12
bits
Sampling rate
200K
Hz
Note: the maximum voltage that the ADC can gather is 2.2V
T5320_User Guide_V1.04
19
2013- 04-15
Smart Machine Smart Decision
Table 10: AT+CADC Read ADC
Description
Read the ADC value from modem. We support 3 type of ADC, raw type, temperature type and voltage type.
SIM PIN
References
NO
Vendor
Syntax
Test Command
Responses
AT+CADC=?
+CADC: (range of supported s)
OK
Write Command
Responses
AT+CADC=
+CADC: 
OK
ERROR
Execution Command
Responses
AT+CADC
Same as AT+CADC= 0:
+CADC: 
OK
Defined values

ADC type:
0 – raw type.
–
temperature type.
–
voltage type(mv)

Integer type value of the ADC.
Examples
AT+CADC=?
+CADC:(0-2)
OK
AT+CADC=0
+CADC: 187
OK
6.3.3
GPIO interfaces
T5320 provides 4 GPIO pins. All GPIOs can be configured as inputs or outputs. User can use AT Commands to
read or write GPIOs status. Refer to document [1] for details.
T5320_User Guide_V1.04
20
2013- 04-15
Smart Machine Smart Decision
Table 11: T5320 GPIOs
T5320 GPIO
CPU Pin No.
I/O
Function
GPIO1
GPIO0
I/O
General input/output PIN. It can be used as wake/interrupt
signal to host from module If it is unused, left open.
GPIO2
GPIO2
I/O
General input/output PIN.
GPIO3
GPIO3
I/O
General input/output PIN.
GPIO4
GPIO5
I/O
General input/output PIN.
Example 1: If user use T5320 GPIO1 pin as an output GPIO:
1) AT+CGDRT=0,1
//set T5320 GPIO1 to output
2) AT+CGSETV=0,1
//set T5320 GPIO1 to high value
Example 2: If user use T5320 GPIO4 pin as an input GPIO:
1) AT+CGDRT=5,0
//set T5320 GPIO4 to input
Please refer to document [1] and document [2] for details.
6.4
LED indicator
A red led indicates the power status, when a valid power appears, the red led will lighten up. But a lighten up red
led does not mean that the terminal has been powered up.
A green led indicates the terminal status and GSM net status, after the terminal been powered up and registered to
the network, it will blink at a certain frequency.
Figure 15: Indicator LED
Table 12: Status of the NETLIGHT indicator (Green)
LED Status
Always On
200ms ON, 200ms OFF
800ms ON, 800ms OFF
T5320 behavior
Searching Network/Call Connect
Data Transmit
Registered network
Off
Power off / Sleep
T5320_User Guide_V1.04
21
2013- 04-15
Smart Machine Smart Decision
6.5
Micro USB interface
T5320 provides a Micro USB interface. This interface is compliant with the USB2.0 specification. The USB2.0
specification requires hosts such as the computer to support full-speed (12Mbps) and high-speed (480Mbps).
USB charging and USB-OTG is not supported.
Figure 16: Micro USB interface
Table 13: AT+CUSBSPD
Switch T5320 USB high or full speed
Description
This command is used to switch the speed of USB between high speed and full speed. If you just want to use full
speed to simplify the circuit then you can use this command to switch the USB speed. This command will save your
configuration so if you don’t change the speed the module will use the latest configuration forever.
This command will only takes effect on the next start-up.
SIM PIN
NO
References
Vendor
Syntax
Test Command
Responses
AT+CUSBSPD=?
+CUSBSPD: (list of supported s)
OK
Read Command
Responses
AT+CUSBSPD?
+CUSBSPD: 
OK
Write Command
Responses
AT+CUSBSPD=
OK
ERROR
Defined values

Integer type and nonvolatile value.
T5320_User Guide_V1.04
22
2013- 04-15
Smart Machine Smart Decision
–
High speed
–
Full speed (default value)
Examples
AT+CUSBSPD=?
+CUSBSPD: (0-1)
OK
AT+CUSBSPD=0
OK
AT+CUSBSPD=1
OK
6.6
USIM Card Interface
The USIM provides the required subscription verification information to allow the mobile equipment to attach to a
GSM or UMTS network. Both 1.8V and 3.0V SIM Cards are supported.
T5320 does not support USIM card “hot” plug.
Figure 17: Installation of SIM Card
T5320_User Guide_V1.04
23
2013- 04-15
Smart Machine Smart Decision
6.7
6.7.1
Antenna interface
Antenna connector
Antenna connector allows transmission of radio frequency (RF) signals between the modem and the external
supplied antenna. The T5320 modem is fitted with a 50Ω male SMA connector.
Figure 18: Antenna interface
6.7.2
Antenna type
The antenna is a very important component in the system. Since the antenna transmits and receives
electromagnetic signal, and its efficiency depends on the antenna’s type, placement and the environment of the
antenna operating.
.The recommended antenna specifications are showed in following table:
Table 14: antenna choosing consideration
GSM 850/900/1800/1900MHz
WCDMA 1900/850MHz(T5320A)
WCDMA 2100/900MHz(T5320E)
WCDMA 2100/850MHz(T5320J)
Frequency range
Impedance
50 ohm
Input power
>33dBm (2W) peak power in GSM
>24dBm (0.25W) peak power in WCDMA
VSWR absolute max.
≤10:1
VSWR recommended
≤2:1
Gain
< 3dBi
6.7.3
Antenna placement
The antenna performance is very easily influenced by other electronic devices. So the antenna placement should
be considered carefully as follow.
1. Place away from other electronic devices or other antennas.
T5320_User Guide_V1.04
24
2013- 04-15
Smart Machine Smart Decision
2.
Place far away from metal material.
3.
Face the base station antenna directly if the signal strength is very weak.
Electrical, Reliability and Radio Characteristics
7.1
Absolute Maximum Ratings
The absolute maximum ratings stated in following table are stress ratings under non-operating conditions. Stresses
beyond any of these limits will cause permanent damage to T5320.
Table 15: Absolute maximum ratings
Symbol
Parameter
Min
Typ
Max
Unit
VBAT
Power supply voltage
30
VI
Input voltage
-0.3
2.8
II
Input current
mA
IO*
Output current
mA
These parameters are for digital interface pins, such as GPIO, UART.
7.2
Recommended Operating Conditions
Table 16: Recommended operating conditions
Symbol
Parameter
Min
Typ
Max
Unit
VBAT
Power supply voltage
30
IIH
High-level input current
-10
10
uA
IIL
Low-level input current
-10
10
uA
VIH
High-level input voltage
2.4
VIL
Low-level input voltage
0.4
VOH
High-level output voltage
2.6
VOL
Low-level output voltage
0.1
TOPER
Operating temperature
-35
+25
+80
℃
TSTG
Storage temperature
-40
+85
℃
7.3
Electro-Static Discharge
T5320 is an ESD sensitive component, so more attention should be paid to the procedure of handling and
packaging. The ESD test results are shown in the following table.
T5320_User Guide_V1.04
25
2013- 04-15
Smart Machine Smart Decision
Table 17: The ESD characteristics (Temperature: 25℃, Humidity: 45 %)
Pin
Contact discharge
Air discharge
Shell
±10KV
±15KV
RF interface
±10KV
±15KV
RS232 interface
±10KV
±15KV
Audio interface
±10KV
±15KV
SIM card holder
±10KV
±15KV
7.4
Operating frequency
The operating frequencies in GSM850, EGSM900, DCS, PCS and WCDMA modes are conform to the
GSM/WCDMA Specifications, shown as bellow.
Table 18: Operating frequency
Mode
Freq.TX(MHz)
Freq.RX(MHz)
Channels(ARF
C)
TX-RX
offset
GSM-850
824.2 – 848.8
869.2 – 893.8
128 - 251
45 MHz
890.0-914.8
935.0-959.8
0–124
45M
880.2-889.8
925.2 - 934.8
975-1023
45M
DCS-1800
1710.2-1784.8
1805.2-1879.8
512–885
95 MHz
PCS-1900
1850.2 - 1909.8
1930.2 - 1989.8
512 - 810
80 MHz
WCDMA 2100
1920 - 1980
2110 - 2170
9612 – 9888
60 MHz
WCDMA 1900
1850 - 1910
1930 - 1990
9262 - 9538
80 MHz
WCDMA 900
880 - 915
925 - 960
2712 - 2863
45 MHz
WCDMA 850
824 - 849
869 - 894
4132 - 4233
45 MHz
E-GSM-900
7.5
Transmitter output power and receiver sensitivity
The T5320’s conducted transmitter output power and receiver sensitivity are shown as bellow:
Table 19: Transmitter output power and receiver sensitivity
Mode
Power(dBm)
Sensitivity(dBm)
GSM-850
+33
-106
E-GSM-900
+33
-106
DCS-1800
+30
-107
PCS-1900
+30
-107
WCDMA2100
+24
-106
WCDMA1900
+24
-106
WCDMA900
+24
-106
WCDMA850
+24
-106
T5320_User Guide_V1.04
26
2013- 04-15
Smart Machine Smart Decision
Software/ Firmware Upgrade
The software can be upgraded via the Micro USB interface with the help of tools provided by SIMCom,
8.1
Tool introduction
The tool name is “SIMCOM 3G Module Software update tools(QDL)”, which runs on the windows OS, customers
can upgrade software conveniently by it.
This tool is a single-road download tool, one terminal can be upgraded by it every time. SIMCom also provides
multi-road download tools for customer’s factory use. Contact SIMCom sales for support.
Please do not power off T5320 during the upgrade.
8.2
Illustration of software updating
Connect the Micro USB port of T5320 to the PC USB port and connect the direct current source adapter.
Installing module USB driver on PC OS. USB interface is mapped to five virtual ports: “SIMTECH USB
Modem”, “SIMTECH NMEA Device”, “SIMTECH ATCOM Device”, “SIMTECH Diagnostics interface”
and “SIMTECH Wireless Ethernet Adapter”.
Figure 19: Virtual ports in computer manager window
Open the tools, the main operation interface as the following figure shows:
Figure 20: QDL window
T5320_User Guide_V1.04
27
2013- 04-15
Smart Machine Smart Decision
Browse the source file
Figure 21: Browse the source file
Software download
Click the
button, then the window will change like the following figure shows.
Figure 22: click download button without power up
T5320_User Guide_V1.04
28
2013- 04-15
Smart Machine Smart Decision
Upgrade in proceeding
Figure 23: Upgrade in proceeding
Finish upgrading
Now the software is the new version, customer can check the software version by “ATI”.
Figure 24: Finish upgrading
T5320_User Guide_V1.04
29
2013- 04-15
Smart Machine Smart Decision
Appendix
A. Related Documents
Table 20: Related documents
SN
Document name
Remark
[1]
SIM5320_ATC
SIM5320 AT Command Manual
[2]
SIM5xxx_GPIO_Applicat
ion_note
Applications Note About SIM5xxx_GPIO
[3]
Audio Application Note
V1.01
Applications Note About T5320 Audio
[4]
ITU-T
Draft
new
recommendationV.25ter
Serial asynchronous automatic dialing and control
[5]
GSM 07.07
Digital cellular telecommunications (Phase 2+); AT command set for GSM
Mobile Equipment (ME)
[6]
GSM 07.10
Support GSM 07.10 multiplexing protocol
GSM 07.05
Digital cellular telecommunications (Phase 2+); Use of Data Terminal
Equipment – Data Circuit terminating Equipment (DTE – DCE) interface
for Short Message Service (SMS) and Cell Broadcast Service (CBS)
[8]
GSM 11.14
Digital cellular telecommunications system (Phase 2+); Specification of
the SIM Application Toolkit for the Subscriber Identity Module – Mobile
Equipment (SIM – ME) interface
[9]
GSM 11.11
Digital cellular telecommunications system (Phase 2+); Specification of
the Subscriber Identity Module – Mobile Equipment (SIM – ME) interface
[10]
GSM 03.38
Digital cellular telecommunications system (Phase 2+); Alphabets and
language-specific information
[11]
GSM 11.10
Digital cellular telecommunications system (Phase 2); Mobile Station
(MS) conformance specification; Part 1: Conformance specification
[12]
3GPP TS 51.010-1
Digital cellular telecommunications system (Release 5); Mobile Station
(MS) conformance specification
[13]
3GPP TS 34.124
Electromagnetic Compatibility (EMC) for mobile terminals and ancillary
equipment.
[14]
3GPP TS 34.121
Electromagnetic Compatibility (EMC) for mobile terminals and ancillary
equipment.
[15]
3GPP TS 34.123-1
Technical Specification Group Radio Access Network; Terminal
conformance specification; Radio transmission and reception (FDD)
[16]
3GPP TS 34.123-3
User Equipment (UE) conformance specification; Part 3: Abstract Test
Suites.
EN 301 908-02 V2.2.1
Electromagnetic compatibility and Radio spectrum Matters
(ERM); Base Stations (BS) and User Equipment (UE) for
IMT-2000. Third Generation cellular networks; Part 2:
Harmonized EN for IMT-2000, CDMA Direct Spread
(UTRA FDD) (UE) covering essential requirements of article
[7]
[17]
T5320_User Guide_V1.04
30
2013- 04-15
Smart Machine Smart Decision
3.2 of the R&TTE Directive
[18]
EN 301 489-24 V1.2.1
Electromagnetic compatibility and Radio Spectrum Matters
Electromagnetic Compatibility (EMC) standard for radio equipment and s
Part 24: Specific conditions for IMT-2000 CDMA Direct Spread (UTR
Mobile and portable (UE) radio and ancillary equipment
[19]
IEC/EN60950-1(2001)
Safety of information technology equipment (2000)
[20]
3GPP TS 51.010-1
Digital cellular telecommunications system (Release 5); Mobile Statio
conformance specification
[21]
GCF-CC V3.23.1
Global Certification Forum - Certification Criteria
[22]
2002/95/EC
Directive of the European Parliament and of the Council of 27 January 200
restriction of the use of certain hazardous substances in electrical and el
equipment (RoHS)
B. Terms and Abbreviations
Table 21: Terms and Abbreviations
Abbreviation
Description
ADC
Analog-to-Digital Converter
AMR
Adaptive Multi-Rate
AT
Attention commands
CS
Coding Scheme
CSD
Circuit Switched Data
CTS
Clear to Send
DTE
Data Terminal Equipment (typically computer, terminal, printer)
DTR
Data Terminal Ready
DTU
Data Transmit Unit
DTX
Discontinuous Transmission
EFR
Enhanced Full Rate
EGSM
Enhanced GSM
ESD
Electrostatic Discharge
ETS
European Telecommunication Standard
FR
Full Rate
GPRS
General Packet Radio Service
GSM
Global Standard for Mobile Communications
HR
Half Rate
IMEI
International Mobile Equipment Identity
Li-ion
Lithium-Ion
MO
Mobile Originated
MS
Mobile Station (GSM engine), also referred to as TE
MT
Mobile Terminated
PAP
Password Authentication Protocol
PBCCH
Packet Broadcast Control Channel
PCB
Printed Circuit Board
PCL
Power Control Level
T5320_User Guide_V1.04
31
2013- 04-15
Smart Machine Smart Decision
PCS
Personal Communication System, also referred to as GSM 1900
PDU
Protocol Data Unit
PPP
Point-to-point protocol
RF
Radio Frequency
RMS
Root Mean Square (value)
RTC
Real Time Clock
RX
Receive Direction
SIM
Subscriber Identification Module
SMS
Short Message Service
TE
Terminal Equipment, also referred to as DTE
TX
Transmit Direction
UART
Universal Asynchronous Receiver & Transmitter
URC
Unsolicited Result Code
USSD
Unstructured Supplementary Service Data
Phonebook abbreviations
FD
SIM fix dialing phonebook
LD
SIM last dialing phonebook (list of numbers most recently dialed)
MC
Mobile Equipment list of unanswered MT calls (missed calls)
ON
SIM (or ME) own numbers (MSISDNs) list
RC
Mobile Equipment list of received calls
SM
SIM phonebook
NC
Not connect
C. Safety Caution
Table 22: Safety caution
Marks
Requirements
When in a hospital or other health care facility, observe the restrictions about the use of mobiles.
Switch the cellular terminal or mobile off, medical equipment may be sensitive to not operate
normally for RF energy interference.
Switch off the cellular terminal or mobile before boarding an aircraft. Make sure it is switched off.
The operation of wireless appliances in an aircraft is forbidden to prevent interference with
communication systems. Forget to think much of these instructions may lead to the flight safety or
offend against local legal action, or both.
Do not operate the cellular terminal or mobile in the presence of flammable gases or fumes. Switch
off the cellular terminal when you are near petrol stations, fuel depots, chemical plants or where
blasting operations are in progress. Operation of any electrical equipment in potentially explosive
atmospheres can constitute a safety hazard.
Your cellular terminal or mobile receives and transmits radio frequency energy while switched on.
RF interference can occur if it is used close to TV sets, radios, computers or other electric
equipment.
T5320_User Guide_V1.04
32
2013- 04-15
Smart Machine Smart Decision
Road safety comes first! Do not use a hand-held cellular terminal or mobile when driving a
vehicle, unless it is securely mounted in a holder for hands free operation. Before making a call
with a hand-held terminal or mobile, park the vehicle.
GSM cellular terminals or mobiles operate over radio frequency signals and cellular networks and
cannot be guaranteed to connect in all conditions, for example no mobile fee or a invalid SIM card.
While you are in this condition and need emergent help, please remember using emergency calls.
In order to make or receive calls, the cellular terminal or mobile must be switched on and in a
service area with adequate cellular signal strength.
Some networks do not allow for emergency call if certain network services or phone features are in
use (e.g. lock functions, fixed dialing etc.). You may have to deactivate those features before you
can make an emergency call.
Also, some networks require that a valid SIM card be properly inserted in the cellular terminal or
mobile.
T5320_User Guide_V1.04
33
2013- 04-15
Smart Machine Smart Decision
Contact us:
Shanghai SIMCom Wireless Solutions Ltd.
Add: SIM Technology Building,No.633,Jinzhong Road,Changning District,Shanghai P.R. China
200335
Tel: +86 21 3235 3300
Fax: +86 21 3235 3301
URL: www.sim.com/wm
T5320_User Guide_V1.04
34
2013- 04-15

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Tagged PDF                      : Yes
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 8.0.0 (Windows)
Company                         : MC SYSTEM
Source Modified                 : D:20130416060522
Create Date                     : 2013:04:16 14:05:55+08:00
Creator Tool                    : Acrobat PDFMaker 8.0 for Word
Modify Date                     : 2013:06:08 09:49:31+08:00
Metadata Date                   : 2013:06:08 09:49:31+08:00
Document ID                     : uuid:e3145d4e-9bff-44d3-8d66-b8a316b6837b
Instance ID                     : uuid:cbb12364-ed34-496d-87f3-014a734481fd
Subject                         : 26
Format                          : application/pdf
Creator                         : cheng.shi
Title                           : 
Page Count                      : 34
Page Layout                     : OneColumn
Author                          : cheng.shi
EXIF Metadata provided by EXIF.tools
FCC ID Filing: UDV-2013060302