Sit La Precisa S p A 058404300 Security/Remote Control Transmitter User Manual

Sit La Precisa S.p.A. Security/Remote Control Transmitter

User Manual

Fig. A: Detach the adapter from the bodyIMPORTANTThe Proflame Transmitter is an integrated part of the Proflame System, which consists of these elements: • Proflame Transmitter, to be used in conjunction with• Integrated Fireplaces Control (Proflame IFC) The Profl ame Transmitter provides for controlling the following hearth appliance functions:1.  Main Burner On/Off2.  Main Burner fl ame modulation (6 levels)3.  Choice of standing or intermittent pilot (CPI/IPI)4.  Thermostat and Smart thermostat functions5.  Accent light modulation (6 levels)6.  Split fl ow valve7.  On/Off relay8.  Comfort Fan speed modulation (6 levels) The Proflame Transmitter uses a streamline design with a simple button layout and informative LCD display (Fig. 1). A Mode Key is provided to index between the features and a Thermostat Key is used to turn on/off or index  through Thermostat functions (Fig. 1 & 2). Additionally, a Key Lock feature is provided (Fig. 23).WARNINGTHE TRANSMITTER AND RECEIVER ARE RADIO FREQUENCY DEVICES. PLACING THE TRANSMITTER IN OR NEAR METAL MAY SEVERELY REDUCE THE SIGNAL RANGE. METALLIC STRUCTURES OR RADIO INTERFERENCES CAN REDUCE THE OPERATIVE DISTANCE OF THE DEVICE DEPENDING ON TYPE OF FIREPLACE, INSTALLATION AND ENVIROMENT.ATTENTION!- TURN “OFF” THE MAIN GAS SUPPLY OF THE APPLIANCE DURING INSTALLATION OR MAINTENANCE OF THE RECEIVER DEVICE.- TURN “OFF” MAIN GAS SUPPLY TO THE APPLIANCE PRIOR TO REMOVING OR REINSERTING THE BATTERIES.- IN CASE OF REMOTE CONTROL MALFUNCTION TURN OFF THE IFC DEVICE USING THE “ON/OFF” MAIN SWITCH.- FOR INSTALLATION/MAINTENANCE SWITCH OFF THE IFC DEVICE REMOVING MAIN POWER SUPPLY PLUG.- THE DEVICE IS NOT SUITABLE FOR THE USE OF RECHARGABLE BATTERIES AND ITS OPERATIVE DISTANCE IS REDUCED WITH LOW BATTERY LEVEL.Remote ControlSupply voltage  4.5 V (three AAA LR03 1.5 V batteries)Ambient temperature ratings  0 - 50 °C (32 - 122 °F)Typical operative distance in free air  12 m Radio frequency  315 MHz ( FCC version )    433.92 MHz ( CE version )TECHNICAL DATAOPERATING PROCEDUREInitializing the System for the first timePower the receiver. Activate the procedure of the receiver address programming, see the receiver instruction (*). The Receiver will “beep” three (3) times to indicate that it is ready to synchronize with a Transmitter. Install the 3 AAA type batteries in the Transmitter battery bay, located on the base of the Transmitter. (fig. 3) With the batteries already installed in the Transmitter, push the On button. The Receiver will “beep” four times to indicate the Transmitter’s command is accepted and sets to the particular code of that Transmitter. The system is now initialized.(*)  The receiver may be independent or integrated to the IFC hearth appliance control module. The receiver instruction may not be independent when part of the IFC.Turn on the ApplianceWith the system OFF, press the ON/OFF Key on the Transmitter. The Transmitter display will show some other active Icons on the screen. At the same time the Receiver wil activate the appliance. A single “beep” from the Receiver will confirm reception of the command.Turn off the ApplianceWith the system ON, press the ON/OFF Key on the Transmitter. The Transmitter LCD display will only show the room temperature (Fig. 6). At the same time the Receiver will turn off the appliance. A single “beep” from the Receiver confirms reception of the command.Fig. 6: Remote Control display.Temperature indication Display With the system in the “OFF” position, press the Thermostat Key and the Mode Key at the same time. Look at the LCD screen on the Transmitter to verify that a C or F is visible to the right of the Room Temperature display. (Fig. 4 and fig. 5)Fig. 3: Battery compartment.9.957.126   01Remote-Flame ControlThe Proflame has six (6) flame levels. With the system on, and the flame level at the maximum in the appliance, pressing the Down Arrow Key once will reduce the flame height by one step until the flame is turned off.The Up Arrow Key will increase the flame height each time it is pressed. If the Up Arrow Key is pressed while the system is on but the flame is off, the flame will come on in the high position. ( Fig. 7 & 8 ) A single “beep” will confirm reception of the command.Fig. 9 Fig. 10SET TEMPERATUREROOM TEMPERATURERoom Thermostat ( Transmitter Operation)The Remote Control can operate as a room thermostat. The thermostat can be set to a desired temperature to control the comfort level in a room.To activate this function, press the Thermostat Key (Fig. 1). The LCD display on the Transmitter will change to show that the room thermostat is “ON” and the set temperature is now displayed (Fig. 9). To adjust the set temperature, press the Up or Down Arrow Keys until the desired set  temperature is displayed on the LCD screen of the Transmitter.Fig. 7:     Flame Off         Flame Level 1 Fig. 8:     Flame level 5    Flame Level MaximumSmart Thermostat (Transmitter Operation) The Smart Thermostat function adjusts the flame height in accordance to the difference between the set point temperature and the actual room temperatures. As the room temperature gets closer to the set point the Smart Function will modulate the flame down. To activate this function, press the Thermostat Key (Fig. 1) until the word "SMART" appears to the right of the temperature bulb graphic (Fig. 11). To adjust the set temperature, press the Up or Down Arrow Keys until the desidered set temperature is displayed on the LCD screen of the Transmitter (Fig. 12). Note. When Smart Thermostat is activated, manual flame height adjustment is disabled.Fan Speed Control If the appliance is equipped with a hot air circulating fan, the speed of the fan can be controlled by the Proflame system. The fan speed can be adjusted through six (6) speeds. To activate this function use the Mode Key (fig.1) to index to the fan control icon (Fig. 13). Use the Up/Down Arrow Keys (Fig.1) to turn on, off or adjust the fan speed (fig. 14). A single “beep” will confirm reception of the command.Fig. 11: Smart flame function Fig. 12Fig. 13 Fig. 14Fig. 4: Remote Control display in Farenheit.       Fig. 5: Remote Control display in Celsius.2 35 64Fig. 1: Proflame Transmitter Back lit LCD displayUP/DOWN Arrow KeyON/OFF KeyTHERMOSTAT KeyMODE KeyFig. 2: Transmittter LCD display.Low battery alarmKey LockRoomTemperatureDimmer ONSet PointTemperature/Level/StateFlame ONThermostat OFF/ON/SMARTComfort fan TransmissionSplit Flow Aux ONCPI modeThe Proflame remote control is supplied with an adapter for wall mounting. Install the controller 1.5 m above floor level, well away from heat sources, kitchens, doors or windows. Metallic structures or radio interferences can reduce the operative distance of the device.Make sure to attach the adapter in a level plane without any distortion. Proceed as follow:• Detach the adapter from the body of the remote control; see Fig. A.• Position the adapter on the wall, mark the points for the fixing holes and drill the wall. • Fix the adapter on the wall using the mounting hardware supplied with the remote control.• Insert the remote control onto the adapter as shown in Fig. B.WALL MOUNTINGFig. B: Adapter and remote controlPROFLAME WALL MOUNT TRANSMITTERUSE AND INSTALLATION INSTRUCTIONSRead the instructions before use. This control must be installed in accordance with the rules in force.
Continous Pilot/Intermittent Pilot (CPI/IPI) selectionWith the system in "OFF" position press the Mode Key (fig. 1) to index to the CPI mode icon (fig. 17 & 18).Pressing the Up Arrow Key will activate the Continous Pilot Ignition mode (CPI). Pressing the Down Arrow Key will return to IPI. A single “beep” will confirm the reception of the command.NOTE:  this function is available only with Proflame IFC.NOTE:  If the system is equipped with a CPI/IPI toggle switch:• Set the CPI/IPI switch to CPI position(switch closed) to enable remote CPI/IPI operation. • Set the CPI/IPI switch to IPI position (switch open) to disable remote CPI/IPI operation. The system will now work in IPI mode only regardless of the selection on the remote control hand set.Remote auxiliary relay controlThe auxiliary function controls the AUX relay outlet. To activate this function use the Mode Key (fig. 1) to index to the AUX icon (fig. 15 & 16).Pressing the Up Arrow Key will activate the outlet. Pressing the Down Arrow Key will turn the outlet off. A single “beep” will confirm the reception of the command.Fig. 15 Fig. 16Fig. 17 Fig. 18This function will lock the keys to avoid unsupervised operation. To activate this function, press the MODE and UP Keys at the same time (fig. 23).To de-activate this function, press the MODE and UP Keys at the same time.KEY LOCKFig. 23TransmitterThe life span of the remote control batteries depends onvarious factors: quality of the batteries used, the numberof ignitions of the appliance, the number of changes to the room thermostat set point, etc.When the Transmitter batteries are low, a Battery Icon will appear on the LCD display of the Transmitter (Fig. 24) before all battery power is lost. When the batteries are replaced this Icon will disappear.LOW BATTERY POWER DETECTIONFig. 24WARNINGFire Hazard. Can cause severe injury or deathThe Transmitter causes ignition of the appliance. The appliance can turn on suddenly. Keep away from the appliance burner when operating the remote system.  Fig. 24: PROFLAME Transmitter dimensional drawingDIMENSIONAL DRAWINGSDimensions in millimeters.Remote dimmer control (Light)The dimmer function controls the Light power outlet by power light control. To activate this function use the Mode Key (fig. 1) to index to the Light icon (fig. 19 & 20).The intensity of the output can be adjusted through six (6) levels. Use the Up/Down Arrow Keys (Fig.1) adjust the output level (fig. 16). A single “beep” will confirm reception of the command.Note. This function is available only with the Proflame IFC.Fig. 19 Fig. 20Split Flow controlThe secondary burner is controlled by the split Flow. To activate this function use the Mode Key (fig. 1) to index to the SPLIT FLOW mode icon (fig. 21 & 22).Pressing the Up Arrow Key will activate the secondary burner. Pressing the Down Arrow Key will turn the secondary burner off. A single “beep” will confirm the reception of the command.Fig. 21 Fig. 2215263632626Ø3Ø311108 97FCC CONFORMITY (for 315MHz version only)  The “Proflame Wall Mount Transmitter” complies with the following requirements:     - FCC (Federal Communications Commission) Part 15   Operation is subject to the following two conditions:     (1) This device may not cause harmful interference, and     (2) This device must accept any interference received, including interference        that may cause undesired operation.   Changes or modification not expressly approved by the party responsible for      compliance could void the user’s authority to operate the equipment.   FCC ID: T99058404300

Navigation menu